Loading...
HomeMy WebLinkAbout305 Mangoustine Ave 03-1912 Fire prevention division Chida PlazaI SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: May 16, 2002 Business Address: 305 Magoustine Occ. Ch.38 Business Business Name: Chida Plaza Ph. (407) 321-1415 FAX (407) 321-1597 Contractor: Spolski Construction Ph. (407) 322-8424 FAX (407)322-8436 Reviewed [ ] Reviewed with comment [ X] Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted. Fire Alarm horn strobes and pull stations required. Please have contractor submit as builds for appliance and low voltage wire specs. 1.1 Application — New Building. Type IV, one (1) story firesprinkler protected; with protection of trusses. 41) 30o s9 -F: 1. 2 Mixed — N/A 1. 3 Special Definitions — Meets F.F.P.C.- 6.1.11.1 (Record keeping/Business transactions). 1. 4Classification of Occupancy — Business F.F.P. C. 1. 5 Classification of Hazard of Contents — Ordinary/6.2.2.2. 1. 6 Minimum Construction — N/R 2. 2 Means of Egress Components — O.K. 2. 3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways) 2. 4 Number of Exits — O.K. 2. 5 Arrangement of Egress — O.K. , two separate (2) 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.6 Travel Distance — O.K. with in 200' ft 2.7 Discharge from Exits — Complies with Chapter #7 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; 2.11 Special Features — 3.1 Protection of Vertical Openings —3.2 Protection from Hazards — N/N 3.3 Interior Finish - Class "A " 3.4 Detection, Alarm and Communications Systems —This is existing (Required per F.F.P.C. 38-3.4.1-Pull stations at every EXIT, Flow switches& tamper switches required on fire sprinkler system) 3.5 Extinguishing Requirements — as per NFPA 10 — Two (2) 2A rated fire extinguishers 3.6 Corridors - One -hour fire rated corridors (exception Fire Sprinkler System) 4 Special Provisions 5 Building Services 5.1 Utilities — shall comply with N.F.P.A . #70 5.2 HVAC — shall comply with N.F.P.A. # 90 A & #90B over 2000 C.F.M. duct detectors required 5.3 Elevators, Escalators, Conveyors: shall meet ANSI safety code for elevators A17.1 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: blueprints required; Monitoring: Required by a U.L. listed Central Station for all mandated fire Sprinklered properties, per city code chapter #9 Other: NFPA 1 3-5.1 Fire Lanes — Not Required u - ' 4•'. SANFORD FIRE DEPARTMENT FIRE PRE VENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 3-6.1 Key Box — Not Required 3-7.1 Bldg. Address Number Posted and Legible — Existing 3 3J5 f'la n9ous+n Ati 0-Igia