HomeMy WebLinkAbout1050 Central Park Dr 01-1067, 01-1200 Fire prevention division Direct furnishingsSANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772
407 302-1022 / FAX (407) 330-5677
Pager (407) 918-0388
Plans Review Sheet
Date: 1/23/01 Business Address: 1050 Central Park Dr. Occ. Ch. 28
Business Name: Direct Furnishings (J. Rowe, Owner) Ph. (407) 328-6364
Contractor: McKee Const. Ph. (407) 323-1150
Reviewed [ ] Reviewed with comment [ X ] Rejected [ ]
Reviewed by: H. A. "Pete" Tucker, Fire Protection Inspector
Comment: Plans reviewed as an Industrial Occupancy. FD reserves right to require applicable
code requirements if occupancy use changes. Sprinkler plans to be submitted for review,
permitting, and inspections. If separate certified contractor does underground fireline, plans to be
submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating
design criteria for sprinkler system needs to be submitted with construction plans. Fire Alarm
plans to be submitted for review, permitting, and inspections. Epoxy room to meet requirements
of NFPA 33. Contractors states that room will have separate ventilation system.
1.1 Application — New Building, Type IV Const., 16,205 sq.ft.
1.2 Mixed — N/A
1.3 Special Definitions — N/N
1.4 Classification of Occupancy — Industrial
1.5 Classification of Hazard of Contents — Ordinary (See Comments)
1.6 Minimum Construction — N/R
2.2 Means of Egress Components — O.K.
2.3 Capacity of Egress — O.K.
2.4 Number of Exits — O.K.
2.5 Arrangement of Egress — O.K.
2.6 Travel Distance — O.K.
2.7 Discharge from Exits — O.K.
2.8 Illumination of Means of Egress — O.K.; will field verify
2.9 Emergency Lighting — O.K.; will field verify
2.10 Marking of Means of Egress — O.K.; will field verify
r
2.11 Special Features — O.K.
3.1 Protection of Vertical Openings — N/N
1
v
4
SANFORD FIRE DEPARTMENT
FIRE PREVENTION DIVISION
300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772
407 302-1022 / FAX (407) 330-5677
Pager (407) 918-0388
3.2 Protection from Hazards — See Comments
3.3 Interior Finish — Class "B"
3.4 Detection, Alarm and Communications Systems — as per NFPA 72
3.5 Extinguishing Requirements — as per NFPA 10
3.6 Corridors — N/A
4 Special Provisions
5 Building Services
5.1 Utilities — as per LSC 7-1
5.2 HVAC — as per LSC 7-2
5.3 Elevators, Escalators, Conveyors (4A-47) — N/A
5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A
Sanford City Code — Chapter 9
Fire Sprinklers: Required; also see 3.5 above
Monitoring: Required by a U.L. listed Central Station for all mandated fire
sprinklered properties
Other: NFPA 1
3-5.1 Fire Lanes — Required if building is more than 150' from street; exception:
building has fire sprinkler system.
3-6.1 Key Box — Required; will field verify
3-7.1 Bldg. Address Number Posted and Legible — Required; will field verify
2
PR' CT TITLE Direct Furnishing
BUILDING TYPE Service Establishments
BUILDING LOCATION Sanford
BUILDING AREA (ft2) 15546.8
BUILDING ANNUAL ENERGY USE
0-------------------------
DESIGN BUILDING BASELINE BUILDING
M i CIOi-----------------------------------------------------------------------------
HEATING ENERGY
Electric Resistance
Electric Furnace
COOLING ENERGY
Direct Expansion
Air Conditioner (PTAC)
DOMESTIC HOT WATER ENERGY
Electric DHW System(s)
BUILDING MISCELLANEOUS
Lights
Equipment
SYSTEM MISCELLANEOUS
Fans
8.48
8.55
3.72
21.64
2.43
1.60
42.20
13.94
3.81
30.27
2.43
7.36
PLANT MISCELLANEOUS
TOTAL ENERGY CONSUMPTION ; 46.42 ; 100.00
PASSES ******
PROJECT TITLE Direct Furnishing
BUILDING TYPE Service Establishments
BUILDING LOCATION Sanford
BUILDING AREA(ft2): 15546.8
BUILDING DESIGN
Exterior Lighting Power 0 W
EXTERIOR LIGHTING CRITERIA:
AREA AREA AREA OR ALLOWANCE
CODE DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
COMPf,IANCE CERTIFICATION:
I hereby certify that the plans and Review of the plans and specifica-
specifications covered by this calcu- tions covered by this calculation
lation are in compliance th the indicates compliance with the
Florida Ener Effi a C D Florida Energy Efficiency Code.
PREPARED BY Before construction is completed,
DATE-0 Q this building will be inspected
for compliance in accorda with
I hereby certify that this'building is Section 553.908, Flori tutes.
in compliance with the Wior da Enercry BUILDING OFFICIAL: ; ,
Efficiency Cr, la, DATE:
OWNER/AGENri
DATE
I hereby certify(*) that the system design is in compliance with the Florida
Energy Efficiency Code.
SYSTEM DESIGNER REGISTRATION/STATE
ARCHITECT :
MECHANICAL:
PLUMBING
ELECTRICAL:
LIGHTING
Signature is required where Florida law requires design to be performed
by registered design professionals. Typed names and registration numbers may
be used where all relevant information is contained on signed/sealed plans.
BUILDING ENVELOPE SYSTEMS COMPLIANCE
CHECK
401.------GLAZING--ZONE 1------------------------------------------------ v-
Elevation Type U SC VLT Shading Area(Sgft)l
East Residential 1 1 1 Continuous Ove
I
451
West Residential 1 1 1 Continuous Ove 451
South Residential 1 1 1 Continuous Ove 681
South Commercial 1 1 1 Continuous Ove 371
Total Glass Area in Zone 1 = 1951
401.------GLAZING--ZONE 2------------------------------------------------ v-
Elevation Type U SC VLT Shading Area(Sgft)l
North Residential 1.23 1 1 None
I
01
Total Glass Area in Zone 2 = 01
401.------GLAZING--ZONE 3------------------------------------------------ v-
Elevation Type U SC VLT Shading Area(Sgft)l
North Residential 1.23 1 1 None
I
01
Total Glass Area in Zone 3 = 01
Total Glass Area = 1951
402.------WALLS--ZONE 1------------------------------------------------ I ---
Elevation Type U Insul R Gross(Sgft)l
East 5/8"Stco/8"CMU/3/4''ISO BTTi7N24"oc 0.149 4.2
I
2501
West 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4.2 2501
South 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4.2 5001
Adjacent 3/4"Stco/2x4@16"oc+RllBatt/',t"Gyp '0.070 11 2601
Total Wall Area in Zone 1 = 12601
402 WALLS --ZONE 2------------------------------------------------ I ---
Elevation Type U Insul R Gross(Sgft)l
South 5/8"Stco/8"CMU/3/ 4"ISO BTWN24"oc 0.149 4.2
I
611
West 5/8'1Stco/8''CMU/3/4"ISO BTWN24"oc 0.149 4.2 2941
West Mtl Bldg wall/R-11 Batt .084 11 2201
West Mtl Bldg wall/R-11 Batt .084 11 461
Adjacent 3/4"Stco./2x4@16"o.c+RllBatt/1-i"Gyp 0.080 11 10921
Total Wall Area in Zone 2 = 17131
402.------WALLS--ZONE 3------------------------------------------------ I ---
Elevation Type U Insul R Gross(Sgft)l
North 5/8"Stco/8''CMU/3/4"ISO BTWN24"oc 0.41 0 9601
East 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.41 0 11201
West 5/8"Stco/8'10M0/3/4"ISO BTWN24"oc 0.41 0 11201
South 5/8"Stco/8"CMU/3/4°'ISO BTWN24"oc 0.41 0 3361
South Mtl Bldg wall/R-11 Batt .084 11 2521
North Mtl Bldg wall/R-11 Batt .084 11 7201
East Mtl Bldg wall/R-11 Batt .084 11 8401
West Mtl Bldg wall/R-11 Batt .084 11 8401
Total Wall Area in Zone 3 = 61881
Total Gross Wall Area = 91611
403.------DOORS--ZONE 1------------------------------------------------ I ---
Elevation Type U Area(Sgft)l
Adjacent 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60
I
211
Total Door Area in Zone 1 = 211
403.------DOORS--ZONE 2---------------------------------------------------
Elevation Type U Area(Sgft)1
1
Acljacent 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 631
Total Door Area in Zone 2 = 631
i403.------DOORS--ZONE 3------------------------------------------------ I ---
Elevation Type U Area(Sgft)1
I
North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 421
West 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 211
South 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 2601
Total Door Area in Zone 3 = 3231
Total Door Area = 4071
404.------ROOFS--ZONE 1------------------------------------------------ I ---
Type Color U Insul R Area(Sgft)1
I
Mtl Bldg Roof/R-19 Batt Light .051 19 15021
Total Roof Area in Zone 1 = 15021
404.------ROOFS--ZONE 2------------------------------------------------ I ---
Type Color U Insul R Area(Sgft)1
1
Mtl Bldg Roof/R-19 Batt Light .051 19 11131
Total Roof A-rea in Zone 2 = 11131
404.------ROOFS--ZONE 3-----------------------------------------
Type Color U Insul R Area(Sgft)1
I
Mtl Bldg Roof/R-19 Batt Light .051 19 129321
Total Roof Area in Zone 3 = 129321
Total Roof Area = 155471
405.------FLOORS-ZONE 1------------------------------------------------ I ---
Type Insul R Area(Sgft)1
I
Slab on Grade/Uninsulated 0 15021
Total Floor Area in Zone 1 = 15021
405.------FLOORS-ZONE -----------------------------------------I
Type Insul R Area(Sgft) I
Slab on Grade/Uninsulated 0 11131
Total Floor Area in Zone 2 = 11131
405.------FLOORS-ZONE 3------------------------------------------------ I ---
Type Insul R Area(Sgft)1
I
Slab on Grade/Uninsulated 0 129321
Total Floor Area in Zone 3 = 129321
Total Floor Area = 155471
406.------INFILTRATION --------------------------------------------------
ICHECKI
Infiltration Criteria in 406.1.ABCD have been met. I I
MECHANICAL SYSTEMS
CHECK
I-----1---
HVAC load sizing has been performed. (407.1.ABCD) I
407.------COOLING SYSTEMS -----------------------------------------------
Type No Efficiency IPLV Tonsl
I
1. Split System 1 10 0 5.001
2. Split System 1 10 0 4.001
3. No Cooling System 0 0 0 0.001
408.------HEATING SYSTEMS -----------------------------------------------1---
Type No Efficiency BTU/hrl
1. Electric Resistance 1 1
I
341301
2. Electric Resistance 1 1 341301
3. No Heating System 0 0 01
409.------VENTILATION --------------------------------------------------- I---
ICHECKI
Ventilation Criteria in 409.1.ABCD have been met. I I
410.-----AIR DISTRIBUTION SYSTEM----------------------------------------1---
CHECKI
I-----1---
Duct sizing and design have been performed. (410.i.ABCD) I I
AHU Type Duct Location R-value)
I. Air Conditioners Unventilated
I
61
2. Air Conditioners Unventilated 61
3. None (Unconditioned Zone) No Ducts 01
I-----1---
CHECKI
Testing and balancing will be performed. (410.1.ABCD) I I
411.-----PUMPS AND PIPING -ZONE -------------------------•----------------I---
Basic prescriptive requirements in 411.1.ABCD have been met. I I
PLUMBING SYSTEMS
411.-----PUMPS AND PIPING -ZONE
Type
1. Non -Circulating
411.-----PUMPS AND PIPING -ZONE
Type
1. Circulating
411.-- -PUMPS AND PIPING -ZONE
Type
1. Circulating
412.-- -WATER HEATING
1----------- ---------------------------I---
R-value/in Diameter Thickness
1
6 .75 1.51
2-------------- ------------------------I---
R-value/in Diameter Thicknessl
i
0 0 01
3--------------------------------------- i---
R-value/in Diameter Thicknessl
I
0 0 01
SYSTEMS -ZONE 1---------------------------------- I ---
Type Efficiency StandbyLoss InputRate Gallonsl
I
1. <=12 kW .91 .9i 9500 301
412.-----WATER HEATING SYSTEMS -ZONE 2---------------------------------- I ---
Type Efficiency StandbyLoss InputRate Gallonsl
1
412.-----WATER HEATING SYSTEMS -ZONE 3 ----------------------------------
Type Efficiency StandbyLoss InputRate Gallonsl
I
ELECTRICAL SYSTEMS
CHECKI
413.-----ELECTRICAL POWER DISTRIBUTION ----------------------------
Metering criteria in 413.1.ABCD have been met. l i
414.-----MOTORS ---------------------------------------------------i-----1---
Motor efficiencies in 414.1.ABCD have been met. I l
415.-----LIGHTING SYSTEMS -ZONE 1 ---------------------------------------
Space Type No Control Typed No Control Type 2 No Watts Area(Sgft)l
r__
Reading, T 1 On/Off 6 None 0 2720 15021
Total Watts for Zone 1 = 27201 -
Total Area for Zone 1 = 1502I
415.- ---LIGHTING SYSTEMS -ZONE 2 ---------------------------------------
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I
1
Carpentry 1 On/Off 6 On/Off 6 1520 11131
Total Watts for Zone 2 = 15201
Total Area for Zone 2 = 11131
415.-----LIGHTING SYSTEMS -ZONE 3--------------------------------------- I ---
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I
I
Material H 1 On/Off 12 None 0 9200 129321
Total Watts for Zone 3 = 92001
Total Area for Zone 3 = 129321
Total Watts = 134401
Total Area = 155471
ICHECKI
Lighting criteria in 415.1.ABCD have been met. I I
1-----i---
16. Operation/maintenance manual will be provided to owner.(102.1)1 I
r--
Not Applicable ****
11GHTING SYSTEM CONTROL REQUIREMENTS:
TOTAL EQUIVALENT
SPACE -------- NO. --------- CONTROLS -------- CONTROL POINTS
NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA
32 Reading, T 1502.0 1 ;On/Off 6;None 0; 6 > 2
42 Carpentry 1112.8 1 ;On/Off 6;0n/Off 6; 12 > 2
47 Material H 12932.0 1 ;On/Off 12;None 0; 12 > 6
PASSES
PROJECT TITLE Direct Furnishing
BUILDING TYPE Service Establishments
BUILDING LOCATION Sanford
BUILDING AREA(ft2): 15546.8
HVAC SYSTEM REQUIREMENTS:
Cooling System; Measure ;Minim.;Minim.; System ; System ; Result ; Result
Type ;#1 #21 #1 #2 ; Eff.#1 ; Eff.#2 ; for #1 ; for #2
Split Sys. ;SEER 10.001 0.001 10.00 ; 0.00 PASSES
Split Sys. ;SEER 10.00; 0.00; 10.00 1 0.00 ; PASSES
Heating System; Measure ; Minimum Req.; Efficiency ; Result
Ele. Resis. ; Et 1.00 N/A
Ele. Resis. ; Et ; 1.00 ; N/A
PASSES ********
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS:
Zone # Duct Location Minimum R-Value Design R-Value Result
1. Unventilated 6.00 6.00 PASSES
2. Unventilated 6.00 6.00 PASSES
3. No Ducts 0.00 0.00 N/A
PASSES ********
PROJECT TITLE Direct Furnishing
BUILDING TYPE Service Establishments
BUILDING LOCATION Sanford
BUILDING AREA(ft2) : 15546.8
WATER HEATING SYSTEM REQUIREMENTS
System ;Measure; Minimum ; Maximum ; Design ; Design ;Result
Type ; ; EF / Et ; SL ; EF / Et ; SL ;
Electric <= 12kW; EF ; 0.8900 0.0000 ; 0.910 ; 0.910 ;PASSES
PASSES ********
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thickness(in)
System Type ; O.D.(in); Minimum Req. ; Design ; Result
Non-Circulating 1 0.75 1 0.601 1.50 PASSES
PASSES ********
N-Master(c)
COMMERCIAL HEAT LOSS / GAIN
Based on ACCA MANUAL N
MANUAL N Copyrighted (c) 1988 by ACCA
Project name Direct Furnishing -Showroom
Address Lot 12 Sanford Central Park
City/State Sanford
Owner
Builder McKee Construction
HVAC contr.: Barnes Htg & Ac
COOLING PARAMETERS
Geographical Location State FLORIDA City Sanford
North Latitude Elevation 28 ° / 14 Ft. Above Sea Level
Relaltive Himidity 50 %
Grains / Lb.(inside) 64
Outdoor Dry Buld Deg F°) 93 °
Outdoor Wet Bulb Deg F°) 76 °
Indoor Dry Bulb Deg F°) 75 °
Indoor Wet Bulb Deg F°) 62.3 °
Outdoor Humidity Ratio 110
Daily Range 16 °
Peak Load Time 1600 Hours
Temperature Differance Td)(Deg F°) 18 °
Cooling Load Td Correction (Deg F°) 3°(+)
HEATING SUMMARY COOLING SUMMARY
TOTAL LOSS : 29687.52 TOTAL SENSIBLE 43920.43
LATENT GAINS 4315.2
TOTAL GAIN : 48235.63
SENSIBLE OVERSIZE @ 20- 8784.086
HVAC Equipment
Heating
Manufacturer Carrier
Htg System 10 kw 34.1 MBTU
COP/HSPF 1
Cooling
Clg System 5 Ton @ 60.0 MBTU
S)EER 10
Air Handler Verticle @ 2000 cfm
HTG AIR FLOW FACTOR = .067368 CLG AIR FLOW FACTOR = .045537
ZONE CFM 729.423 ZONE CFM 2000.005
SENSIBLE HEAT RATIO = .91
GLASSSOLAR---------------------------------------------------------- ----
TYPE GLASS FACES
AREA Sc U-VALUE LOSS/BTUH GAIN/BTUH
SINGLE CLEAR East 45.4 1 1679.8 1679.8
SINGLE CLEAR South 104.7 1 3873.9 2617.5
SINGLE CLEAR West 45.4 1 1679.8 8172
GLASSCONDUCTION ----------------------------------------------------------
SINGLE CLEAR 45.4 1 638.6 621.19
SINGLE CLEAR 104.7 1 1468.8 1428.75
SINGLE CLEAR 45.4 1 638.6 621.19
WALLS-----------------------------------------------------------------------
WALL FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH
East 204.6 4.2 15 1135.53 1104.84
TYPE :8in.CONC.N/W BLK
South 395.3 4.2 15 2193.92 1600.96
TYPE :Bin.CONC.N/W ELK
West 204.6 4.2 15 1135.53 644.49
TYPE :8in.CONC.N/W ELK
ADJACENT 239 11 07 216.6535 376.425
TYPE :WOOD FRAME -ADJACENT
WALL SUB TOTAL 4681.633 3726.715
DOORS-----------------------------------------------------------------------
DOOR FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH
North 21 n/a 36 945 120.96
TYPE :STEEL
CEILINGS------------- -------------------------------------------
AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH
TYPE :
WITH SUSPENDED CEILING
ROOF COLOR: LITE 1502 19 05 2778.7 6008
FLOORS----------------------------------------------------------------------
SLAB PERIMETER 126 0 81 4082.4 000.00
STRUCTURAL SUB TOTALS 22485.23 25013.61
OTHER SENSIBLE GAINS
PEOPLE 6 N/A 1500
FLOUR/LIGHTING 2720 Watts N/A 9403.86
ICAND/LIGHTING 0 N/A 0
INTERNAL GAINS N/A 3000
VENTILATION 90 CFM 3330 1749.6
ROOM SENSIBLE 25815.23 40667.07
DUCT LOSS & GAIN 3872.285 3253.365
TOTAL SENSIBLE 29687.52 43920.43
LATENT GAINS
PEOPLE N/A 1500
VENTILATION N/A 2815.2
TOTAL LOAD 29687.52 48235.63
F__ -
N-Master(c)
COMMERCIAL HEAT LOSS /GAIN
Based on ACCA MANUAL N
MANUAL N Copyrighted (c) 1988 by ACCA
Project name Direct Furnishing -Epoxy {
Address Lot 12 Sanford Central Park {
City/State Sanford {
Owner {
Builder McKee Construction I
HVAC contr.: Barnes Htg & Ac {
COOLING PARAMETERS
Geographical Location ----> State FLORIDA City : Sanford
North Latitude / Elevation { 28 ° / 14 Ft. Above Sea Level
Relaltive Himidity { 50 %
Grains / Lb.(inside) { 64
Outdoor Dry Buld (Deg F°) I 93 °
Outdoor Wet Bulb (Deg F°) I 76 °
Indoor Dry Bulb (Deg F°) { 75 °
Indoor Wet Bulb (Deg F°) { 62.3 °
Outdoor Humidity Ratio { 110
Daily Range { 16
Peak Load Time { 1600 Hours
Temperature Differance (Td)(Deg F°) { 18 °
Cooling Load Td Correction (Deg F°) 30(+)
HEATING SUMMARY COOLING SUMMARY
TOTAL LOSS : 29410.2 TOTAL SENSIBLE 25526.61
LATENT GAINS 11257.2
TOTAL GAIN : 36783.8
SENSIBLE OVERSIZE @ 20% 5105.321
HVAC Equipment
Heating
Manufacturer Carrier
Htg System 10 kw 34.1 Mbtu
COP/HSPF 1
Cooling
Clg System 4 Ton @ 48.0 MBTU
S)EER 10
Air Handler Verticle @ 1600 cfm
HTG AIR FLOW FACTOR = .054403 CLG AIR FLOW FACTOR = .06268
ZONE CFM = 722.6093 ZONE CFM = 1600.008
SENSIBLE HEAT RATIO = .69
GLASSSOLAR---------------------------------------------------------------
TYPE GLASS FACES
F
AREA Sc U-VALUE LOSS/BTUH GAIN/BTUH
SINGLE CLEAR North 100 0 0 0
i
GLASS CONDUCTION----------------------------------------------------------
SINGLE CLEAR 100 0 3 2.92
WALLS-----------------------------------------------------------------------
ViALL FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH
South 61.36 4.2 15 340.55 248.51
TYPE :8in.CONC.N/W BLK
South 46.02 11 07 119.19 128.86
TYPE :STEEL FRAME
West 293.6 4.2 15 1629.48 924.84
TYPE :Bin.CONC.N/W BLK
West 220.2 11 07 570.32 1078.98
TYPE :STEEL FRAME
ADJACENT 1029 11 07 932.7885 1620.675
TYPE :WOOD FRAME -ADJACENT
WALL SUB TOTAL 3592.329 4001.865
DOORS---------------------------------------------------------------------
DOOR FACES AREA R-VALUE U-VALUE LOSS BTUH GAIN BTUH
North 63 n/a 36 2835 362.88
TYPE :STEEL
CEILINGS--------------------------------------------------------------------
AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH
TYPE
WITH SUSPENDED CEILING
ROOF COLOR: LITE 1112.8 19 05 2058.68 4451.2
FLOORS----------------------------------------------------------------------
SLAB PERIMETER 166.74 0 81 5402.376 000.00
STRUCTURAL SUB TOTALS 16694.08 8842.205
OTHER SENSIBLE GAINS
PEOPLE 6 N/A 2250
FLOUR/LIGHTING 320 Watts N/A 1106.34
ICAND/LIGHTING 1200 N/A 3771.6
INTERNAL GAINS N/A 3000
VENTILATION 240 CFM 8880 4665.6
ROOM SENSIBLE 25574.08 23635.75
DUCT LOSS & GAIN 3836.113 1890.86
TOTAL SENSIBLE 29410.2 25526.61
LATENT GAINS
PEOPLE N/A 3750
VENTILATION N/A 7507.2
TOTAL LOAD 29410.2 36783.8
Whole Building Performance Method for Commercial Buildings
i ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
I Florida Department of Community Affairs
Form 40OA-97
FLA/COM-97 Version 2.2
PROJECT NAMEDirect Furnishing PERMITTING OFFICE: ADDRESS: _
Lot 12 Sanford Central Park _Sanford Sanford
CLIMATE ZONE: 5 OWNER:
PERMIT NO: AGENT:
JURISDICTION NO: 691500 BUILDING
TYPE: Service Establishments CONSTRUCTION
CO_NDITION: New construction DESIGN
COMPLETION: _Finished Building CONDITIONED
FLOOR AREA: _2614.8 NUMBER OF ZONES: 3 MAX.
TONNAGE OF EQUIPMENT PER SYSTEM: 5 COMPLIANCE
CALCULATION: METHOD
A DESIGN CRITERIA RESULT A.
WHOLE BUILDING 46.42 100.00 PASSES PRESCRIPTIVE
REQUIREMENTS: LIGHTING
LIGHTING
CONTROL REQUIREMENTS PASSES HVAC
EQUIPMENT COOLING
EQUIPMENT 1.
SEER 10.00 10.00 PASSES 2.
SEER 10.00 10.00 PASSES HEATING
EQUIPMENT 1.
Et 1.00 N/A 2.
Et 1.00 N/A AIR
DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1.
Unventilated 6.00 6.00 PASSES 2.
Unventilated 6.00 6.00 PASSES 3.
No Ducts 0.00 0.00 N/A REHEAT
SYSTEM TYPES USED NO
REHEAT SYSTEM is USED WATER
HEATING EQUIPMENT 1.
EF 0.91 0.89 PASSES PIPING
INSULATION REQUIREMENTS 1.
Non -Circulating 1.50 0.60 PASSES
D 50 Ca,r Pa-+-f- fir.
re ,F v r n + sh y s Zv.
M 0 106-7t ol -tam