HomeMy WebLinkAbout1050 Central Park Dr 01-1067, 01-1200 Fire prevention division Direct furnishingsSANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 Plans Review Sheet Date: 1/23/01 Business Address: 1050 Central Park Dr. Occ. Ch. 28 Business Name: Direct Furnishings (J. Rowe, Owner) Ph. (407) 328-6364 Contractor: McKee Const. Ph. (407) 323-1150 Reviewed [ ] Reviewed with comment [ X ] Rejected [ ] Reviewed by: H. A. "Pete" Tucker, Fire Protection Inspector Comment: Plans reviewed as an Industrial Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. If separate certified contractor does underground fireline, plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Fire Alarm plans to be submitted for review, permitting, and inspections. Epoxy room to meet requirements of NFPA 33. Contractors states that room will have separate ventilation system. 1.1 Application — New Building, Type IV Const., 16,205 sq.ft. 1.2 Mixed — N/A 1.3 Special Definitions — N/N 1.4 Classification of Occupancy — Industrial 1.5 Classification of Hazard of Contents — Ordinary (See Comments) 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — O.K. 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — O.K. 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K. 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify r 2.11 Special Features — O.K. 3.1 Protection of Vertical Openings — N/N 1 v 4 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, FI. 32772 407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 3.2 Protection from Hazards — See Comments 3.3 Interior Finish — Class "B" 3.4 Detection, Alarm and Communications Systems — as per NFPA 72 3.5 Extinguishing Requirements — as per NFPA 10 3.6 Corridors — N/A 4 Special Provisions 5 Building Services 5.1 Utilities — as per LSC 7-1 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; also see 3.5 above Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: building has fire sprinkler system. 3-6.1 Key Box — Required; will field verify 3-7.1 Bldg. Address Number Posted and Legible — Required; will field verify 2 PR' CT TITLE Direct Furnishing BUILDING TYPE Service Establishments BUILDING LOCATION Sanford BUILDING AREA (ft2) 15546.8 BUILDING ANNUAL ENERGY USE 0------------------------- DESIGN BUILDING BASELINE BUILDING M i CIOi----------------------------------------------------------------------------- HEATING ENERGY Electric Resistance Electric Furnace COOLING ENERGY Direct Expansion Air Conditioner (PTAC) DOMESTIC HOT WATER ENERGY Electric DHW System(s) BUILDING MISCELLANEOUS Lights Equipment SYSTEM MISCELLANEOUS Fans 8.48 8.55 3.72 21.64 2.43 1.60 42.20 13.94 3.81 30.27 2.43 7.36 PLANT MISCELLANEOUS TOTAL ENERGY CONSUMPTION ; 46.42 ; 100.00 PASSES ****** PROJECT TITLE Direct Furnishing BUILDING TYPE Service Establishments BUILDING LOCATION Sanford BUILDING AREA(ft2): 15546.8 BUILDING DESIGN Exterior Lighting Power 0 W EXTERIOR LIGHTING CRITERIA: AREA AREA AREA OR ALLOWANCE CODE DESCRIPTION LENGTH WATTS Exterior Lighting Power Allowance 0.00 W COMPf,IANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifica- specifications covered by this calcu- tions covered by this calculation lation are in compliance th the indicates compliance with the Florida Ener Effi a C D Florida Energy Efficiency Code. PREPARED BY Before construction is completed, DATE-0 Q this building will be inspected for compliance in accorda with I hereby certify that this'building is Section 553.908, Flori tutes. in compliance with the Wior da Enercry BUILDING OFFICIAL: ; , Efficiency Cr, la, DATE: OWNER/AGENri DATE I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT : MECHANICAL: PLUMBING ELECTRICAL: LIGHTING Signature is required where Florida law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401.------GLAZING--ZONE 1------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft)l East Residential 1 1 1 Continuous Ove I 451 West Residential 1 1 1 Continuous Ove 451 South Residential 1 1 1 Continuous Ove 681 South Commercial 1 1 1 Continuous Ove 371 Total Glass Area in Zone 1 = 1951 401.------GLAZING--ZONE 2------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft)l North Residential 1.23 1 1 None I 01 Total Glass Area in Zone 2 = 01 401.------GLAZING--ZONE 3------------------------------------------------ v- Elevation Type U SC VLT Shading Area(Sgft)l North Residential 1.23 1 1 None I 01 Total Glass Area in Zone 3 = 01 Total Glass Area = 1951 402.------WALLS--ZONE 1------------------------------------------------ I --- Elevation Type U Insul R Gross(Sgft)l East 5/8"Stco/8"CMU/3/4''ISO BTTi7N24"oc 0.149 4.2 I 2501 West 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4.2 2501 South 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.149 4.2 5001 Adjacent 3/4"Stco/2x4@16"oc+RllBatt/',t"Gyp '0.070 11 2601 Total Wall Area in Zone 1 = 12601 402 WALLS --ZONE 2------------------------------------------------ I --- Elevation Type U Insul R Gross(Sgft)l South 5/8"Stco/8"CMU/3/ 4"ISO BTWN24"oc 0.149 4.2 I 611 West 5/8'1Stco/8''CMU/3/4"ISO BTWN24"oc 0.149 4.2 2941 West Mtl Bldg wall/R-11 Batt .084 11 2201 West Mtl Bldg wall/R-11 Batt .084 11 461 Adjacent 3/4"Stco./2x4@16"o.c+RllBatt/1-i"Gyp 0.080 11 10921 Total Wall Area in Zone 2 = 17131 402.------WALLS--ZONE 3------------------------------------------------ I --- Elevation Type U Insul R Gross(Sgft)l North 5/8"Stco/8''CMU/3/4"ISO BTWN24"oc 0.41 0 9601 East 5/8"Stco/8"CMU/3/4"ISO BTWN24"oc 0.41 0 11201 West 5/8"Stco/8'10M0/3/4"ISO BTWN24"oc 0.41 0 11201 South 5/8"Stco/8"CMU/3/4°'ISO BTWN24"oc 0.41 0 3361 South Mtl Bldg wall/R-11 Batt .084 11 2521 North Mtl Bldg wall/R-11 Batt .084 11 7201 East Mtl Bldg wall/R-11 Batt .084 11 8401 West Mtl Bldg wall/R-11 Batt .084 11 8401 Total Wall Area in Zone 3 = 61881 Total Gross Wall Area = 91611 403.------DOORS--ZONE 1------------------------------------------------ I --- Elevation Type U Area(Sgft)l Adjacent 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 I 211 Total Door Area in Zone 1 = 211 403.------DOORS--ZONE 2--------------------------------------------------- Elevation Type U Area(Sgft)1 1 Acljacent 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 631 Total Door Area in Zone 2 = 631 i403.------DOORS--ZONE 3------------------------------------------------ I --- Elevation Type U Area(Sgft)1 I North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 421 West 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 211 South 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 2601 Total Door Area in Zone 3 = 3231 Total Door Area = 4071 404.------ROOFS--ZONE 1------------------------------------------------ I --- Type Color U Insul R Area(Sgft)1 I Mtl Bldg Roof/R-19 Batt Light .051 19 15021 Total Roof Area in Zone 1 = 15021 404.------ROOFS--ZONE 2------------------------------------------------ I --- Type Color U Insul R Area(Sgft)1 1 Mtl Bldg Roof/R-19 Batt Light .051 19 11131 Total Roof A-rea in Zone 2 = 11131 404.------ROOFS--ZONE 3----------------------------------------- Type Color U Insul R Area(Sgft)1 I Mtl Bldg Roof/R-19 Batt Light .051 19 129321 Total Roof Area in Zone 3 = 129321 Total Roof Area = 155471 405.------FLOORS-ZONE 1------------------------------------------------ I --- Type Insul R Area(Sgft)1 I Slab on Grade/Uninsulated 0 15021 Total Floor Area in Zone 1 = 15021 405.------FLOORS-ZONE -----------------------------------------I Type Insul R Area(Sgft) I Slab on Grade/Uninsulated 0 11131 Total Floor Area in Zone 2 = 11131 405.------FLOORS-ZONE 3------------------------------------------------ I --- Type Insul R Area(Sgft)1 I Slab on Grade/Uninsulated 0 129321 Total Floor Area in Zone 3 = 129321 Total Floor Area = 155471 406.------INFILTRATION -------------------------------------------------- ICHECKI Infiltration Criteria in 406.1.ABCD have been met. I I MECHANICAL SYSTEMS CHECK I-----1--- HVAC load sizing has been performed. (407.1.ABCD) I 407.------COOLING SYSTEMS ----------------------------------------------- Type No Efficiency IPLV Tonsl I 1. Split System 1 10 0 5.001 2. Split System 1 10 0 4.001 3. No Cooling System 0 0 0 0.001 408.------HEATING SYSTEMS -----------------------------------------------1--- Type No Efficiency BTU/hrl 1. Electric Resistance 1 1 I 341301 2. Electric Resistance 1 1 341301 3. No Heating System 0 0 01 409.------VENTILATION --------------------------------------------------- I--- ICHECKI Ventilation Criteria in 409.1.ABCD have been met. I I 410.-----AIR DISTRIBUTION SYSTEM----------------------------------------1--- CHECKI I-----1--- Duct sizing and design have been performed. (410.i.ABCD) I I AHU Type Duct Location R-value) I. Air Conditioners Unventilated I 61 2. Air Conditioners Unventilated 61 3. None (Unconditioned Zone) No Ducts 01 I-----1--- CHECKI Testing and balancing will be performed. (410.1.ABCD) I I 411.-----PUMPS AND PIPING -ZONE -------------------------•----------------I--- Basic prescriptive requirements in 411.1.ABCD have been met. I I PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE Type 1. Non -Circulating 411.-----PUMPS AND PIPING -ZONE Type 1. Circulating 411.-- -PUMPS AND PIPING -ZONE Type 1. Circulating 412.-- -WATER HEATING 1----------- ---------------------------I--- R-value/in Diameter Thickness 1 6 .75 1.51 2-------------- ------------------------I--- R-value/in Diameter Thicknessl i 0 0 01 3--------------------------------------- i--- R-value/in Diameter Thicknessl I 0 0 01 SYSTEMS -ZONE 1---------------------------------- I --- Type Efficiency StandbyLoss InputRate Gallonsl I 1. <=12 kW .91 .9i 9500 301 412.-----WATER HEATING SYSTEMS -ZONE 2---------------------------------- I --- Type Efficiency StandbyLoss InputRate Gallonsl 1 412.-----WATER HEATING SYSTEMS -ZONE 3 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallonsl I ELECTRICAL SYSTEMS CHECKI 413.-----ELECTRICAL POWER DISTRIBUTION ---------------------------- Metering criteria in 413.1.ABCD have been met. l i 414.-----MOTORS ---------------------------------------------------i-----1--- Motor efficiencies in 414.1.ABCD have been met. I l 415.-----LIGHTING SYSTEMS -ZONE 1 --------------------------------------- Space Type No Control Typed No Control Type 2 No Watts Area(Sgft)l r__ Reading, T 1 On/Off 6 None 0 2720 15021 Total Watts for Zone 1 = 27201 - Total Area for Zone 1 = 1502I 415.- ---LIGHTING SYSTEMS -ZONE 2 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I 1 Carpentry 1 On/Off 6 On/Off 6 1520 11131 Total Watts for Zone 2 = 15201 Total Area for Zone 2 = 11131 415.-----LIGHTING SYSTEMS -ZONE 3--------------------------------------- I --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)I I Material H 1 On/Off 12 None 0 9200 129321 Total Watts for Zone 3 = 92001 Total Area for Zone 3 = 129321 Total Watts = 134401 Total Area = 155471 ICHECKI Lighting criteria in 415.1.ABCD have been met. I I 1-----i--- 16. Operation/maintenance manual will be provided to owner.(102.1)1 I r-- Not Applicable **** 11GHTING SYSTEM CONTROL REQUIREMENTS: TOTAL EQUIVALENT SPACE -------- NO. --------- CONTROLS -------- CONTROL POINTS NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 NO. DESIGN CRITERIA 32 Reading, T 1502.0 1 ;On/Off 6;None 0; 6 > 2 42 Carpentry 1112.8 1 ;On/Off 6;0n/Off 6; 12 > 2 47 Material H 12932.0 1 ;On/Off 12;None 0; 12 > 6 PASSES PROJECT TITLE Direct Furnishing BUILDING TYPE Service Establishments BUILDING LOCATION Sanford BUILDING AREA(ft2): 15546.8 HVAC SYSTEM REQUIREMENTS: Cooling System; Measure ;Minim.;Minim.; System ; System ; Result ; Result Type ;#1 #21 #1 #2 ; Eff.#1 ; Eff.#2 ; for #1 ; for #2 Split Sys. ;SEER 10.001 0.001 10.00 ; 0.00 PASSES Split Sys. ;SEER 10.00; 0.00; 10.00 1 0.00 ; PASSES Heating System; Measure ; Minimum Req.; Efficiency ; Result Ele. Resis. ; Et 1.00 N/A Ele. Resis. ; Et ; 1.00 ; N/A PASSES ******** AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS: Zone # Duct Location Minimum R-Value Design R-Value Result 1. Unventilated 6.00 6.00 PASSES 2. Unventilated 6.00 6.00 PASSES 3. No Ducts 0.00 0.00 N/A PASSES ******** PROJECT TITLE Direct Furnishing BUILDING TYPE Service Establishments BUILDING LOCATION Sanford BUILDING AREA(ft2) : 15546.8 WATER HEATING SYSTEM REQUIREMENTS System ;Measure; Minimum ; Maximum ; Design ; Design ;Result Type ; ; EF / Et ; SL ; EF / Et ; SL ; Electric <= 12kW; EF ; 0.8900 0.0000 ; 0.910 ; 0.910 ;PASSES PASSES ******** PIPING INSULATION REQUIREMENTS: Pipe Insulation Thickness(in) System Type ; O.D.(in); Minimum Req. ; Design ; Result Non-Circulating 1 0.75 1 0.601 1.50 PASSES PASSES ******** N-Master(c) COMMERCIAL HEAT LOSS / GAIN Based on ACCA MANUAL N MANUAL N Copyrighted (c) 1988 by ACCA Project name Direct Furnishing -Showroom Address Lot 12 Sanford Central Park City/State Sanford Owner Builder McKee Construction HVAC contr.: Barnes Htg & Ac COOLING PARAMETERS Geographical Location State FLORIDA City Sanford North Latitude Elevation 28 ° / 14 Ft. Above Sea Level Relaltive Himidity 50 % Grains / Lb.(inside) 64 Outdoor Dry Buld Deg F°) 93 ° Outdoor Wet Bulb Deg F°) 76 ° Indoor Dry Bulb Deg F°) 75 ° Indoor Wet Bulb Deg F°) 62.3 ° Outdoor Humidity Ratio 110 Daily Range 16 ° Peak Load Time 1600 Hours Temperature Differance Td)(Deg F°) 18 ° Cooling Load Td Correction (Deg F°) 3°(+) HEATING SUMMARY COOLING SUMMARY TOTAL LOSS : 29687.52 TOTAL SENSIBLE 43920.43 LATENT GAINS 4315.2 TOTAL GAIN : 48235.63 SENSIBLE OVERSIZE @ 20- 8784.086 HVAC Equipment Heating Manufacturer Carrier Htg System 10 kw 34.1 MBTU COP/HSPF 1 Cooling Clg System 5 Ton @ 60.0 MBTU S)EER 10 Air Handler Verticle @ 2000 cfm HTG AIR FLOW FACTOR = .067368 CLG AIR FLOW FACTOR = .045537 ZONE CFM 729.423 ZONE CFM 2000.005 SENSIBLE HEAT RATIO = .91 GLASSSOLAR---------------------------------------------------------- ---- TYPE GLASS FACES AREA Sc U-VALUE LOSS/BTUH GAIN/BTUH SINGLE CLEAR East 45.4 1 1679.8 1679.8 SINGLE CLEAR South 104.7 1 3873.9 2617.5 SINGLE CLEAR West 45.4 1 1679.8 8172 GLASSCONDUCTION ---------------------------------------------------------- SINGLE CLEAR 45.4 1 638.6 621.19 SINGLE CLEAR 104.7 1 1468.8 1428.75 SINGLE CLEAR 45.4 1 638.6 621.19 WALLS----------------------------------------------------------------------- WALL FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH East 204.6 4.2 15 1135.53 1104.84 TYPE :8in.CONC.N/W BLK South 395.3 4.2 15 2193.92 1600.96 TYPE :Bin.CONC.N/W ELK West 204.6 4.2 15 1135.53 644.49 TYPE :8in.CONC.N/W ELK ADJACENT 239 11 07 216.6535 376.425 TYPE :WOOD FRAME -ADJACENT WALL SUB TOTAL 4681.633 3726.715 DOORS----------------------------------------------------------------------- DOOR FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH North 21 n/a 36 945 120.96 TYPE :STEEL CEILINGS------------- ------------------------------------------- AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH TYPE : WITH SUSPENDED CEILING ROOF COLOR: LITE 1502 19 05 2778.7 6008 FLOORS---------------------------------------------------------------------- SLAB PERIMETER 126 0 81 4082.4 000.00 STRUCTURAL SUB TOTALS 22485.23 25013.61 OTHER SENSIBLE GAINS PEOPLE 6 N/A 1500 FLOUR/LIGHTING 2720 Watts N/A 9403.86 ICAND/LIGHTING 0 N/A 0 INTERNAL GAINS N/A 3000 VENTILATION 90 CFM 3330 1749.6 ROOM SENSIBLE 25815.23 40667.07 DUCT LOSS & GAIN 3872.285 3253.365 TOTAL SENSIBLE 29687.52 43920.43 LATENT GAINS PEOPLE N/A 1500 VENTILATION N/A 2815.2 TOTAL LOAD 29687.52 48235.63 F__ - N-Master(c) COMMERCIAL HEAT LOSS /GAIN Based on ACCA MANUAL N MANUAL N Copyrighted (c) 1988 by ACCA Project name Direct Furnishing -Epoxy { Address Lot 12 Sanford Central Park { City/State Sanford { Owner { Builder McKee Construction I HVAC contr.: Barnes Htg & Ac { COOLING PARAMETERS Geographical Location ----> State FLORIDA City : Sanford North Latitude / Elevation { 28 ° / 14 Ft. Above Sea Level Relaltive Himidity { 50 % Grains / Lb.(inside) { 64 Outdoor Dry Buld (Deg F°) I 93 ° Outdoor Wet Bulb (Deg F°) I 76 ° Indoor Dry Bulb (Deg F°) { 75 ° Indoor Wet Bulb (Deg F°) { 62.3 ° Outdoor Humidity Ratio { 110 Daily Range { 16 Peak Load Time { 1600 Hours Temperature Differance (Td)(Deg F°) { 18 ° Cooling Load Td Correction (Deg F°) 30(+) HEATING SUMMARY COOLING SUMMARY TOTAL LOSS : 29410.2 TOTAL SENSIBLE 25526.61 LATENT GAINS 11257.2 TOTAL GAIN : 36783.8 SENSIBLE OVERSIZE @ 20% 5105.321 HVAC Equipment Heating Manufacturer Carrier Htg System 10 kw 34.1 Mbtu COP/HSPF 1 Cooling Clg System 4 Ton @ 48.0 MBTU S)EER 10 Air Handler Verticle @ 1600 cfm HTG AIR FLOW FACTOR = .054403 CLG AIR FLOW FACTOR = .06268 ZONE CFM = 722.6093 ZONE CFM = 1600.008 SENSIBLE HEAT RATIO = .69 GLASSSOLAR--------------------------------------------------------------- TYPE GLASS FACES F AREA Sc U-VALUE LOSS/BTUH GAIN/BTUH SINGLE CLEAR North 100 0 0 0 i GLASS CONDUCTION---------------------------------------------------------- SINGLE CLEAR 100 0 3 2.92 WALLS----------------------------------------------------------------------- ViALL FACES AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH South 61.36 4.2 15 340.55 248.51 TYPE :8in.CONC.N/W BLK South 46.02 11 07 119.19 128.86 TYPE :STEEL FRAME West 293.6 4.2 15 1629.48 924.84 TYPE :Bin.CONC.N/W BLK West 220.2 11 07 570.32 1078.98 TYPE :STEEL FRAME ADJACENT 1029 11 07 932.7885 1620.675 TYPE :WOOD FRAME -ADJACENT WALL SUB TOTAL 3592.329 4001.865 DOORS--------------------------------------------------------------------- DOOR FACES AREA R-VALUE U-VALUE LOSS BTUH GAIN BTUH North 63 n/a 36 2835 362.88 TYPE :STEEL CEILINGS-------------------------------------------------------------------- AREA R-VALUE U-VALUE LOSS/BTUH GAIN/BTUH TYPE WITH SUSPENDED CEILING ROOF COLOR: LITE 1112.8 19 05 2058.68 4451.2 FLOORS---------------------------------------------------------------------- SLAB PERIMETER 166.74 0 81 5402.376 000.00 STRUCTURAL SUB TOTALS 16694.08 8842.205 OTHER SENSIBLE GAINS PEOPLE 6 N/A 2250 FLOUR/LIGHTING 320 Watts N/A 1106.34 ICAND/LIGHTING 1200 N/A 3771.6 INTERNAL GAINS N/A 3000 VENTILATION 240 CFM 8880 4665.6 ROOM SENSIBLE 25574.08 23635.75 DUCT LOSS & GAIN 3836.113 1890.86 TOTAL SENSIBLE 29410.2 25526.61 LATENT GAINS PEOPLE N/A 3750 VENTILATION N/A 7507.2 TOTAL LOAD 29410.2 36783.8 Whole Building Performance Method for Commercial Buildings i ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION I Florida Department of Community Affairs Form 40OA-97 FLA/COM-97 Version 2.2 PROJECT NAMEDirect Furnishing PERMITTING OFFICE: ADDRESS: _ Lot 12 Sanford Central Park _Sanford Sanford CLIMATE ZONE: 5 OWNER: PERMIT NO: AGENT: JURISDICTION NO: 691500 BUILDING TYPE: Service Establishments CONSTRUCTION CO_NDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _2614.8 NUMBER OF ZONES: 3 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5 COMPLIANCE CALCULATION: METHOD A DESIGN CRITERIA RESULT A. WHOLE BUILDING 46.42 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 10.00 PASSES 2. SEER 10.00 10.00 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A 2. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Unventilated 6.00 6.00 PASSES 2. Unventilated 6.00 6.00 PASSES 3. No Ducts 0.00 0.00 N/A REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 0.91 0.89 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating 1.50 0.60 PASSES D 50 Ca,r Pa-+-f- fir. re ,F v r n + sh y s Zv. M 0 106-7t ol -tam