HomeMy WebLinkAbout4035 W 1st St Fire inspection New construction Night OwlSANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: December 7, 2005 Business Address: 4035 West First Street Occ. Ch. Business Occupancy 38 Business Name: Night Owl Ph. () FAX () Contractor: McKee Construction Ph. (407) 323-1150 FAX (407) 323-9304 Architect: O.B. Architectural Dynamics Reviewed p Reviewed with comment [X] Rejected Reviewed by: Timothy Robles, Fire Protection Inspector/plans Examiner Comment: Plans reviewed as Business Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler System require per local city ordinance. Fire sprinkler system shall be monitored per City of Sanford local ordinance. Fire sprinkler contractor to submit design criteria for sprinkler system. Fire alarm system will be required to have horn strobes and pull stations through -out, New code requirement to notify each tenant 1.1 Application — New Building. 15,00 sq. ft. , Type IV- fire sprinkler protected 1.2 Mixed — N/A 1.3 Special Definitions — Meets F.F.P.C. - 6.1.11.1 (Record keeping/Business transactions). 1.4Classification of Occupancy —Business F.F.P. C. 1.5 Classification of Hazard of Contents — Ordinary/6.2.2.2. 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 302-2526 2.3 Capacity of Egress — One person per 100 sq ft (50 or more occupants shall comply with 44' isle ways) 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — Two separate EXITS 2.6 Travel Distance — O.K., Does not exceed 93' ft 6" inches 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — Ok, will field verify? 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features —N/A 3.1 Protection of Vertical Openings - Shall be constructed as a smoke barrier with degree of compartments 3.2 Protection from Hazards — N/N 3.3 Interior Finish - Class "A "or "B " 3.4 Detection, Alarm and Communications Systems Required fire sprinkler monitoring per City Fire Code 3.5 Extinguishing Requirements —as per NFPA 10 —Two Q 3A rated fire extinguishers required in this building in each lease able unit (See blue prints) 3.6 Corridors — Rated wall required between buildings. One -hour fire rated corridors exception Fire Sprinkler System) 4 Special Provisions 5 Building Services 5.1 Utilities - Additional fire hydrant required per L.D.R. (250' FT from principle building) 5.2 HVAC - shall comply with N.F.P.A. # 90 A & #90B over 2000 C.F.M. duct detectors required (blue prints show none over 1,200 c.fm) 2 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 302-2526 5.3 Elevators, Escalators, Conveyors: 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: blue prints required, Monitoring: Required by a U.L. listed Central Station for all mandated fire Sprinklered properties, per city code chapter #9 Provide at lease one horn strobe per tenant space for independent notification. Other: NFPA 1 3-5.1 Fire Lanes — Not Required 3-6.1 Key Box — Required; will field veri , see application, and see blue prints for location 3-7.1 Bldg. Address Number Posted and Legible - Required; will field veri , see blue print for visible location