Loading...
HomeMy WebLinkAbout330 Seminole Blvd 04-494 New construction Trail head building fire inspectionAll T - = Nftoo; wF REVISIONS PERMIT # ()4-- lq G DATE sue- SOQ ADDRESS CONTRACTOR PH # -4v 7= 77/— FAX # -7 `7j - DESCPRITION OF REVISIONS MAY 0 5 Anna UTILITIES FIRE BLDG r SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2.520 / FAX (407) 302-2.526 Pager (407) 918-0395 Plans Review Sheet Date: November 18, 2003 Business Address: 330 E. Seminole Ave. Occ. Ch. 36 New Mercantile Business Name: Trail Head Building Ph. () Contractor: E.D.C. Ph. (407) 771-4442 FAX. (407) 771-4452 Comment: Plans reviewed as Mercantile Occupancy Class "C". Fl) reserves right to require applicable code requirements if occupancy use changes. Application — New Building. 2,910 sq. ft. New Mercantile occupancy 1.1 Mixed — N/A 1.2 Special Definitions — N/N 1.3 Classification of Occupancy — Class "C" (LESS THAN 3,000 sq. ft.) 1.4 Classification of Hazard of Contents — Ordinary per 6.2.2.2. F.F.P.C. 1.5 Minimum Construction — N/R (NO SPECIAL REQUIRMENTS) 2.2 Means of Egress Components -isles shall be maintained at all tames 2.3 Capacity of Egress — O K Less than 40occupants 2.4 Number of Exits — One (1) See exception #36- 2.4. Less than 75' (ft) Maximum according to blueprints 60' (ft) 2.5 Arrangement of Egress — O.K., will field verify, per section 7.5>F.F.P. C. 2.6 Travel Distance — Shall not exceed 75' 36- 2.4. t Y SANFORD FIRE DEPARTMENT SA FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 302-2526 Neer (407) 918-0395 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features -Reserved 3.1 Protection of Vertical Openings — Provide a basic degree of compartments 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "B" "A" or "C" allowed per 10.2.8.1 3.4 Detection, Alarm and Communications Systems — Not required 3.5 Extinguishing Requirements — aer NFPA10, two (2)` 3A10 B C fire"extznguashers requiresp 3.6 Corridors — 4 Special Provisions 5 Building Services 5.1 Utilities — as per sec 9-1 5.2 HVAC — as per sec 9-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 FireSprinklers:E Not required Monitoring: Not required. Other: NFPA 1 3-5.1 Fire Lanes — Not required 3-6.1 Key Box — Not required 3-7.1 Bldg. Address Number Posted and Legible: Post address on building 6" in size see blueprints) 2