HomeMy WebLinkAbout550 W 1 St 03-1678 New construction Eckerds Fire inspectionF- AD F- 'D SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: April 3, 2003 Business Address: 550 West First Street Occ. Ch. 34(Mercantile) Business Name: Eckerd Drug Store Ph. (813) 253-3535 Contractor: Unknown at time of submittal Ph. O Architect/Engineer: Lyman Davidson Dooly, , inc Ph. (813) 288-9299 Ph. (813) 228-8046 Reviewed [ ] Reviewed with comment _ _[ X ]I Rejected [ Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner floc - Comment: Plans reviewed as (Mercantile) Occupancy (14, 581 sq. ft. ) FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections ( design criteria not stated). If separate certified contractor does underground fireline, plans to be submitted for review, permitting, and inspections. Sealed letter from Engineer of Record stating design criteria for sprinkler system needs to be submitted with construction plans. Fire Alarm plans to be submitted for review, permitting, and inspections. 1.1 Application — New Building. Type V> Fire sprinkler protected 1.2 Mixed — N/A 1.3 Special Definitions — Bulk merchandise retail 1.4 Classification of Occupancy — (Mercantile) 1.5 Classification of Hazard of Contents — (Mercantile) Class "B " 1.6 Minimum Construction — See Sanford build depts. Comments 2.2 Means of Egress Components — The rear exit in the storage area shall have ,yellow stripping on floor 44" showing delineated path of travel. 2.3 Capacity of Egress — Per table 7.3 in (F.F.P. C.) sales floor (])per 30 sq. ft. Storage one person (1) per 300 sq. ft 2.4 Number of Exits — Additional EXIT SIGN REQUIRED (See Blue Prints) 1 r- 'i T F 'D i SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 2.5 Arrangement of Egress — No stora e allowed in the 44" isle exit access see blue Tints', g g --g— --- -- L_. ___P ) 2.6 Travel Distance — Exits were placed less than 200' (ft), from any point of travel inside building. 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify; with 2.9 Emergency Lighting — Two more emergency lights required I > "main electrical shut off'; 2>Pharmacy 2.10 Marking of Means of Egress —Additional Exit sign required 2.11 Special Features — (Reserved) 3.1 Protection of Vertical Openings — Shall comply with sec8.2.5 ofF.FP.C. 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "A" &`B" only allowed inside store 3.4 Detection, Alarm and Communications Systems —'as per NFPA 72 with phone monitoring% 1 pull station/ I smoke detector; 3.5 Extinguishing Requirements —as per NFPA 10; five (8)>4A rated fire extinguishers required, ;see page A-1.1 (additional one (1) required in Pharmacy, &upstairs mezzanine; 3.6 Corridors — See Sanford building dept. for construction requirment 4 Special Provisions 5 Building Services 5.1 Utilities — New fire hydrant required within 250' ofprinciple building. 5.2 HVAC — as per LSC 9-2 ;(tie all duct detectors into main fire alarm panel) see B-P Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: Required; also see 3.5 above Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered_properties Other: NFPA 1 2 F -D F D SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 3-5.1 Fire Lanes — Required by F.D. C hose connection 3-6.1 Key Box — Required; will field verify; see application 3-7.1 Bldg. Address Number Posted and Legible — Required; will field verify; see on blue Printsi