HomeMy WebLinkAbout1295 - 1511 W. Airport Blvd 06-88, 06-902 Window a_c unit Brioa9s+i1i A zEber,
46'
Florida EnerQY Efficiency Code For Building Construction
Florida Department of Community Affairs
EnergyGauge F1aCom v 2.11 FORM 40OA-2004
Whole Building Performance Method for Commercial Buildings
Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500)
Short Desc: BRIOBLDG#4 Project: BRIO BUILDING #4 - TENANT
Owner:
Address: 1295 WEST AIRPORT BLVD
BRIO COMMERCE CENTER BUILDING #4
City: SANFORD
State: FL PermitNo: 0--
Zip: 0 Storeys: 1
Type: Office *Conditioned Area: 150 • denotes lighted
Class: Renovation to existing building * Cond + UnCond Area: 150 area. Does not include
wall crosection areas
Max Tonnage: 0.7 (if different, write in)
Compliance Summary
Component Design Criteria Result
Gross Energy Use 93.77 107.21 PASSES
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
None Entered
PASSES
None Entered
PASSES
None Entered
Yes/No/NA
IMPORTANT NOTE: An input report Print -Out from EnergyGauge Com of
this design building must be submitted along with this Compliance Report.
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004
I hereby certify that the plans and
specifications covered by this calculation are
In compliance with the Florida Energy
Efficiency Code. .—
PREPARED BY: GUS BOBES JR P.E.
Review of the plans and specifications covered by this
calculation indicates compliance with the Florida Energy
Code. Before construction is completed, this building will be
inspected for compliance in accordance with Section
553.908, F.S.
BUILDING OFFICIAL:
DATE: DATE:
I hereby certify that this building is in compliance
with.the Florida Energy Efficiency Code.
OWNER AGENT,
DATE:
If required by Florida law, I hereby certify (') that the system design is in
REGISTRATIONcompliancewiththeFloridaEnergyCode.
No.
ARCHITECT:
ELECTRICAL SYSTEM DESIGNER:
LIGHTING SYSTEM DESIGNER:
MECHANICAL SYSTEM DESIGNER:
PLUMBING SYSTEM DESIGNER:
Signature is required where Florida Law requires design to be performed by registered design professionals.
Typed names and registration numbers may be used where all relevant information is contained on signed/sealed
plans.
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 2
Project: BRIOBLDG#4
Title: BRIO BUILDING #4 - TENANT
Type: Office
Total
Whole Building Compliance
Design
88.24
93.77
Reference
100.00
107.21
ELECTRICITY(MBtu/kWh/$ 88.24 100.00
1,756.00 2,019.00
93.77 107.21
AREA LIGHTS 22.06 25.00
429.00 505.00
22.91 2682
MISC EQUIPMT 16.18 16.18
330.00 330.00
17.62 17.52
SPACE COOL 33.82 30.88
680.00 624.00
36.31 33.13
VENT FANS 16.18 27.94
317.00 560.00
16.93 29.74
Penalties (if any): Modified Points: = 88.24
External Lighting Compliance
Description Category Allowance Area or Length ELPA CLP
W/Unit) or No. of Units (W) (VV)
Sgft or ft)
None
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 3
I i 1
Project: BRIOBLDG#4
Title: BRIO BUILDING #4 - TENANT
Type: Office
WEA File: Orlando.TMY)
Lighting Controls Compliance
Acronym Ashrae
ID
Description Area No. of Design Min Compli-
sq.ft) Tasks CP CP ance
PrOZolSpl 16 Office - Open Plan 150 1 2 1 PASSES
PASSES
Project: BRIOBLDG#4
Titles: BRIO BUILDING #4 - TENANT
Type; Office
WEA File: Orlando.TMY)
System Report Compliance
PrOSyl System I Constant Volume Packaged No. of Units
Terminal System i
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System PTAC 7000 to 8000 Btu/h 11.00 11.00 PASSES
Cooling Mode)
Air Handling Air Handler (Supply) - 0.50 0.90 PASSES
System -Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design Min Design Min Category Comp
No Eff Eff IPLV IPLV liance
None
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 4
M
Project:, BRIOBLDG#4
Title: BRIO BUILDING #4 - TENANT
Type: Office
WEA File: Orlando.TMY)
Water Heater Compliance
Description Type Category
Design Min Design Max Comp
Eff Eff Loss Loss liance
Water Heater 1 Electric water heater > 12 fkW] 0.85 0.02 267.41 PASSES
PASSES
Piping System Compliance
Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
F] .SF.F]
None
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 5
1 T '
Project: BRIOBLDG#4
Title: BRIO BUILDING #4 - TENANT
Type: Office
WEA File: Orlando.TMY)
Other Required Compliance
Category Section Requirement (write N/A in box if not applicable) Check
Infiltration 406.1 Infiltration Criteria have been met
System 407.1 HVAC Load sizing has been performed
Ventilation. 409.1 Ventilation criteria have been met
ADS 410.1 Duct sizing and Design have been performed
T & B 410.1 Testing and Balancing will be performed
Motors 414.1 Motor efficiency criteria have been met
Lighting 415.1 Lighting criteria have been met
O & M 102.1 Operation/maintenance manual will be provided to owner
Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it
Report 101 Input Report Print -Out from EnergyGauge FlaCom attached?
3/8/2006 EnergyGauge FlaCom v 2.11 FORM 40OA-2004 6
EnergyGauge F1aCom v 2.11
INPUT DATA REPORT
Proiect Information
Project Name: BRIOBLDG#4 Orientation: North
Project Title: BRIO BUILDING #4 - TENANT Building Type: Office
Address: 1137 WEST AIRPORT BLVD Building Classification: Renovation to existing building
BRIO COMMERCE CENTER BUILDING #4
State: FL No.of Storeys: I
Zip: 0
GrossArea: 150
Owner:
Zones
No Acronym Description Type Area Multiplier Total Area
lsf] lsfl1PrOZolZoneICONDITIONED150.0 1 150.0
Spaces
No Acronym Description Type Depth Width Height Multi Total Area Total Volume
lftl lftl lftl plier lsfl Icfl
3/8/2006
EnergyGauge F1aCom v 2.11
1
In Zone: PrOZol
j 1 Prozo1Sp1 Zo0Sp1 Office - Open Plan 12.50 12.00 9.00 1 150.0 1350.0 Q
y
Lighting
No Type Category No. of Watts per Power Control Type No.of
Luminaires Luminaire W] Ctrl pts
In Zone: PrOZol
In Space: PrOZo1Sp1
1 Recessed Fluorescent - General Lighting
No
2 70 140 Manual On/Off 2vent
Walls
No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value
IN ft] plier stl Btu/hr. sf. F] Capacity lb/cf] [h.sf.FBtu]
Btu/sf.F]
In Zone: PrOZol
1 PrOZo1Wa2 Metal 12.00
siding/R 11 Batt/0.5"
12.00 1 144.0 North 0.0957 0.7570 16.80 10.45
Gyp
2 PrOZo 1 Wa2 Metal 13.00
siding/RI 1 Batt/0.5"
12.00 1 156.0 West 0.0957 0.7570 16.80 10.45
Gyp
3 PrOZolWa3 0.5 Piy/35/8" Mtl 25.00 10.00 1 250.0 North 0.0798 0.5388 7.98 12.54std@24"oc/R 11 /0.51'
Gyp
FF"' Windows
No Description Type Shaded U SHG Vis.Tr W H (Effec) Multi Total Area
Btu/hr sf F] ft] ft] plier ISf]
In Zone: PrOZol
In Wall: PrOZo1Wa2
1 PrOZo1Wa2Wi1 SINGLECLEAR No 1.0018 0.81 0.88 6.00 7.00 1 42.0
3/8/2006
EnergyGauge FlaCom v 2.11
2
Doors
No Description Type Shaded? Width H (Effec) Multi- Area Cond. Dens. Heat Cap. R-Value
ft] [ft] plier sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] (h.sf.FBtuj
In Zone:
In all:
Roofs
No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value
IN IN plier sf] deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu]
In Zone: PrOZol
I PrOZoIRfl Mtl Bldg Roof/R-19 12.00 13.25 1 159.0 0.00 0.0492 1.34 9.49 20.34Batt
Skylights
No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area
Btu/hr sf F) ft] IN [sf] [Sfl
In Zone:
In Roof:
Floors
No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value
ft] [ft] plier st] Btu/hr. sf. F] [Btu/sE F] [lb/cf] [h.sf.F/Btu]
In Zone: PrOZol
t PrOZo I F1I Concrete floor, 12.00 13.25 1 159.0 0.5987 9.33 140.00 1.67carpetandrubber
pad
3/8/2006 EnergyGauge FlaCom v 2.11
3
Systems
PrOSyl System i Constant Volume Packaged Terminal
System
No. Of Units 1
Component Category Capacity Efficiency IPLV
I Cooling System (PTAC 7000 to 8000 BUA (Cooling 8000.00 11.00
Mode))
2 Air Handling System -Supply (Air Handler (Supply) - 265.00 0.50
Constant Volume)
Plant
Equipment Category Size Inst.No Eff. IPLV
Water Heaters
W-Heater Description Capacit Cap.Unit I/P Rt. Efficienc Loss
1 Electric water heater 50 [Gal] 16382 [M] 0.8500 [Ef] 0.0200 Btu/h]
Ext-Lighting
Description Category No. of Watts per Area/Len/No. of units
Luminaires Luminaire [sf/ft/No]
Control Type Wattage
W]
El
Piping
No Type Operating Insulation Nomonal pipe
Temperature Conductivity Diameter
F] [ Btu-in/h.sf.F] [inj
Insulation
Thickness
inj
Is Runout?
aia+cvvo EnergyGauge FlaCom v 2.11 4
Fenestration Used
Name Glass Type No. of
Glass
SHGCConductance VLT
Panes
Btu/h.sf.Fl
ApLbWndl SINGLE CLEAR 1 1.0018 0.8150 0.8810
Materials Used
Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat
Used [h.sf.FBtul IN Btu/h.ft.Fl lb/cfl Btu/Ib.FI
187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000BOARD,1/21N
151 Matil51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000
41N
178 Madl78 CARPET W/RUBBER PAD Yes 1.2300
211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900N,.
12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.200023Mat1236in. Insulation No 20.0000 0.5000 0.0250 5.70 0.
2000IL
4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.100094Mat194BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.35003/SIN
Constructs Used
3/8/2006 EnergyGauge FlaCom v 2.11 5
No
1004
Name Simple
Construct
Concrete floor, carpet and rubber pad No
Massless Conductance Heat Capacity
Construct [Btu/h.sf.Fj [Btu/sf.F]
No 0.60 9.33
Density
ib/cfj
140.00
RValue
h.sf.FBtu]
16703
Layer Material
No.
Material Thickness
ftj
Framing
Factor
1
2
151
178
CONC HW, DRD, 140LB, 41N
CARPET W/RUBBER PAD
0.3333 0.00
0.00
No
1015
Name Simple
Construct
0.5 Ply/35/8" Mtl std@24"oc/R11/0.5" Gyp No
Massless Conductance Heat Capacity
Construct [Btu/h.sf.F] [Btu/sf.F]'
No 0.08 0.54
Density
lb/cfj
7.98
RValue
h.sf.FBtu]
12.5383
Layer Material
No.
Material Thickness
IN
Framing
Factor
1
2
3
211
12
187
POLYSTYRENE,EXP.,1/2IN,
3 in. Insulation
GYP OR PLAS BOARD,1/2IN
0.0417
0.2500
0.0417
0.00
0.00
0.00
No
1020
Name Simple
Construct
Metal siding/RI 1Batt/0.5"Gyp No
Massless Conductance Heat Capacity
Construct [Btu/h.sEF] [Btu/sf.F]
No 0.10 0.76
Density
Ib/cfj
16.80
RValue
h.sLFBtu]
10.4535
Layer Material
NO'
Material Thickness
IN
Framing
Factor
1
2
3
4
12
187
Steel siding
3 in. Insulation
GYP OR PLAS BOARD,1/21N
0.0050
0.2500
0.0417
0.00
0.00
0.00
3/8/2006
EnergyGauge F1aCom v 2.11
6
No Name Simple Massless Conductance Heat Capacity Density RValue
Construct Construct [Btu/h.sf.F] [Btu/sf.F) Ib/cfJ [h.sf.F/Btu]
1047 MtI Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3366
Layer Material Material Thickness Framing
No. ft] Factor
1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.00
2 23 6 in. Insulation 0.5000 0.00
3/8/2006 EnergyGauge FlaCom v 2.11 7
0
GE AWimces
AJESWAS6 — GEC 115 Volt Window/Well Mount Heat and Cool Unit
Feeftires and Benefits
6,000 BTU
4100 BTU hea,,
1380 Watts beat
10 EEF
1, 15 Volts
Mechanical conttDis
Variable position -thermostat
four-way air diiection,
Up-fron,,, washable air filter
2 CooI,,2 heat/2 tan only speeds
Mode+ AJES06LSB — Cameo Mile
SPedficabm CreaNd IM
39M
I
0
E Appliances
AJES061.S8 — GEI 115 Vott Window/Wall Mount Heat and Cool Unit
Wall Case Dimensions (in inchas
16-7T .
26
Nate: Wher, installing slide -out chassis units in through -the -wall
applications, keep louvers free. Do not restrict air Now areas.
Note: This unit is note intended to be the primary source of heat.
S"K ificmbn Cralaw 11C
39M
Parallel
1 15 Amp
a
IBIIP¢5 B! LdK1L`P L:tP7 P
NSP'J aP bw MBSS'Bi1.4 LBtlPrr+ 3PlS
an hi. BC Y idlFwtlxro
1.1.dM d Yx 53MiU^,..
For answers io your Monmram`GE Profoe' v
GE' awliance amsiiors. visit our websn at
GEAtmiiance.s corr. or call
GE Answer ;.enTP" sennu,. R+R626.2Nf
ow
Gf Applialem
AJESOSLSB — GE11115 Volt Window/Wall Mount Heat and Cool Unit
Dimensions din imAes)
Make frame if desired or caulk
between case and siding
Frame Construction
Brick Block and Brick
Frame Construction
5pWAlcation crMaUad 111111113
am
Lintel
OUTSIDE
Caulking —
Drip Rail
Plaster Line wstaWaion m 'ano tine: A find to onerim c 26 /F x 15 3t4` Ilea'
of intrusions is reouired. Keen clearance of G' trorr side wails Brici
veneer or frarne walls should have woord muldinc surrrindm rase to TrimMoldingprovidefrmaniionmvornscrews, < ase can ne `asrenez d .ti, ,: if
desired) ancr, o1 blocv walls wftr, screws sunk nn. iea-, exoans or snnel Now
Units snould oe caulked on all four sides of case to tiw buiiorna INSIDE
exterior to assure building inteorm Two
WaN tans tor, Teaaea 00n town on When
the art conditioner is affetea as a tenant omurn; these wall cases
provide protection against outside elemenis. Flexible
Mounting Position open
cells with
mortar or
insulation RAB47 —
rrcatdes wall case, am -nor grille and steer closure owels RAB40—
irt:ltaies wall case, exterwr grille. steel clowre panel and two
layers of i nsu aiion. Rtaadwd
YWII! Can RAW Solid-
sitled wall case fabricated of galvanued steel witrtra ed enamel finish. Welded
areas are coated with a seelm cornootnd tc heio resist rust and
corrosion. Po"r gasket suntxarls opening tc assure fight weather sea..
Akimiram grille W13i is included. Panels on interior and between cam
and grille vowde weather prose *n prior t0 rastaletrorn of chassis.
orovide firm anchoring with screws. Case can be fastened drrectiv to
trcK or tim walls with smws sunk in lead expansion sheds ap3r^i
ietl : i; 6Dt" 9i+
WR5 f.9 URMrw:Tx: Rim. ApCw. ®
L Lame—, 100. &UP
For answers
10 your MonoOrarr' GE Profile' r, GE appliance
ouestitms visit our website a GEApplrances.corr
rn ca G: Answer
Center' servrm 800.62e.200CC