Loading...
HomeMy WebLinkAbout2101 E Lake Mary Blvd 03-1408, 03-1409 Roof and Stair hand rails InvacareLv LAKP AWY 6?1-o g�—Y-skmool D3—/�FoP M1r*R-• 11-2003 21: 1 G GLE ASSOCIATES 407 G5e 4410 P.01i07 a GLE AsSocIA-FEs, INC. Architects - Engineers - Endronmental Consultants March 11, 2003 Mr. Bob Bott City of Sanford Building Code Compliance Office 300 N. Park Avenue Sanford, Florida 32771 RE: Additions and Renovations to Invacare 2101 E. Lake Mary Blvd. Sanford Florida GLE Project No.: 03000-04076 Dear Mr. Bott This letter responds to your letter of February 24, 2003 regarding Building Code Plan Review for the above -referenced project. 1.0 Roof Ton Equipment RTV -6 1.1 Comment Roof top equip. within 10' of roof edge required 42" guardrail RTV-6 Response A 6' long guardrail will be set on the parapet wall and will be 42" above the roof with a intermediate rail centered so a 21" sphere will not pass through. Guardrail will be centered on equipment. Fabrication will be same as interior guardrails. See supplemental drawing A-101 2.0 Interior Stairs and Guardrail 2.1 Comment Stairs not accessible to public, guardrails required to prevent passage of 21" sphere 1320 N. Semoran Boulevard - Suite 203 - Orlando, FL 32807 - 407/658-4151 - Fax: 407/658.4410 Architect AA 0002369 - Engineer EB 0005483 - Asbestos ZA 0000034 - Geology GB 0000297 OIAP-11-2003 21:17 GLE ASSOCIATES 407 G5e 4410 P.02i07 Response Intermediate rail is shown on plans for guardrail but covered with tick mark of dimension line. Will clarify with sketch. Intermediate rail will be added to stair hand rail. All intermediate rails will be installed to prevent passage of 21" sphere. See supplemental drawing A-101 3. 0 Openings in Tilt -up Panels 3.1 Comment Submit detail of opening in existing tilt -up panels where sawcut, submit re-inforcement. Response See attached letter from our structural engineer Glenn Amore, P.E. 4.0 Smoke Detector in Supply and Return 4.1 Comment Air handler 2,000 CFM or greater smoke detector in supply & return. Response Smoke detector will be added if not shown in the supply and return of air Handlers 2000 CFM or greater. 5.0 Life Safeq Plan 5.1 Comment Submit life safety plan showing exits & travel distances & proximity to burn off ovens. Response Exit is within the 250' requirement of a sprinkled building. See supplemental drawings A-102 (2 pages) Full size drawing can be furnished if required. MAR-11-2003 21:17 GLE ASSOCIATES 407 GSS 4410 P.03/07 Please do not hesitate to contact us if you have questions concerning any of our responses to your comments. Sincerely, GLE Associates, Inc. David A. Miller Project Manager C. David Strong, Owner Strong Construction Paul Visnoski, Invacare R. Quinn Turner, GLE Project File WworklArch103000 Projects\04076 Invacare Constniction AdministrationVesponse to City of Sanford review 03-10-0240c MAR-11-2003 21:17 GLE ASSOCIATES 407 G58 4410 PIPE P05T5 rn � I I I T`"FIGAL 42" HIGH GU,4RD R,41L STEEL PIPE HAND RAIL BOTH 51DE5 OF STAIR WELD TO 5TRIW-,ER 4'-0' OZ WITH PIPE POSTS PROVIDE INTERMEDIATE RAIL IN CENTER T I'PIGAL 5TAIR HAND RAIL PROVIDE 4' X 4' X 1/4' STEEL PLATE WITH 4 5/5' 0 ANCHOR5 TOP OF PARAPET PIPE P05T5 INTERMEDIATE RAIL CENTERED ON P05T , TOP OP ROOF -- 42 " PIG- 4 GU,4}RD R,41 L AT PARAPET SUF)FLEMENTAL EDfRAUJINe:1 �' aar�r�w�ie.,•a�a onwiaR��o. wao,Rao� p.K�:o auuaanetm as" t..rerd�se 4tooa gaia� seen uaJ �w MAR-11-2003 21:18 Amore Enginee Structural Enain"rs ing, Inc. GLE ASSOCIATES 407 658 4410 P.05i07 To: David Miller (CLE Associates) CC: Bob Bett (City of Sanford Bldg. Dept) From: Marc Graper, P.E. (Amore Engineering) Date: February 26, 2003 Subject: Invacare Addition/Renovation - Bldg Dept Comments Project #: 02-100 Plans Review Comments. (3) Submit detail of opening in existing tilt up panels where sawcut, submit reinforcement Note. comments (1), (2), (4), and (5) do not apply to the structural design, and shall not be addressed herein. Response: Upon review of the existing 7-in, thick concrete tiitwall and the proposed penetrations' sizes and locations, it has been determined that none of the proposed sawcut penetrations require any additional structural reinforcemenL Please call, if there are any questions/concerns. 2277 Lee Read, Suite 225 Wlnttr Park. Florida 32769 rhome (407) 6474 MO Fax (407) 647.6119 FEB-26 -2003 14 : 00 APO f a7 r; t 1 q MAR-11-2003 21:18 GLE ASSOCIATES 407 658 4410 P.06i07 II I X M o O a I •I !• x r.• 4'-0' &PPLEMMAL DRAM �!!�/11iR11�YKtbl NVACARE '°'pa 'a GU Anoatte4 IAG SrMF010,:{.0WA OWmalft. GM Man alP�y. wlAo®r ue�egs cra�eooaam>Ams� aav�� ai�ffi fJQR'gdMoIaM�10 ® on !dam wsao 4wlo A-102 MAR-11-2003 21:18 GLE ASSOCIATES 407 Gt>b 441U r.UriUr 110-.t a I �lti • • WeftWWA DRAIUMRam WACAW a w.ra+r+r /� .r/� WMV, A fL�MWWAIMW. B+IMI�•B/MYlfi�ihlMliQIwO+ UPA-102 K RA1 �YOl61f�E:[O 013M00. RLRG� ]i001 lYIJ Neil [MKO TOTAL P.07 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1.788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: February 24„ 2003 Business Address: 2101 E. Lake Mary Blvd. Occ. Ch. # 40 Industrial Business Name: INVACARE CORP. Ph. (� Fax () Contractor: G.L.E. Associates Inc. Ph. (407) 658-4151 Fax (407)658- 4410 eviewed with co�m�ment ] Rejected Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner - New addition to existing Industrial Occupancy 4179 sq. ft. Comment: Fire department will require the following fire code items to be addressed prior to permitting. I.I.- Relocation of existingfire hydrant 1. Provide Sign by fire hydrant stating "NO PARKING FIRE LANE" 2. Paint fire hydrant red 3. Provide "crash ballads" around fire hydrant for protection 4. Provide Blue Reflective fire hydrant marker on pavement in front of fire hydrant 5. Paint on ground in front of fire hydrant NO PARKING 1.2- Provide Floor Plan 1. Life safety diagram showing path of travel out of building around the Oven area 2. Fire sprinkler blue prints required for permitting on the 4179 sq. ft. new addition 1 ---------------