HomeMy WebLinkAbout413 W 1 St 01-1907 Electrical New construction Community Natl Bank#/3 AJ /S" 5r Application foil Site Development Perm t- i' Date To the Administrative official: 'rile undersigned hereby applies for a permit for the following described Work: Owner 00MANITY, NATION&L 5AWK Address:_41*3 Wi F11257 =eeT Nature cif' Work SITE Met 4 SHOWN ON SITE VL" Legal Deset4holl or Tax Identification Number of Property 3o - is Applicant's Name �4bLos©M P.;,& Applicant's Address 90 4 N [120 Applicant's Plione,Number 4,11_1V, Applicant's Fax Number 0,1 Fee 00 $3 5 1% of cost of Proposed work I Certify that the above information Is true and correct and I will coniply with all applicable codes and ordinances of the City of Sanford, Fl. Administrative Official Applicant Signature CALL ENGINEERING DEPARTMENT 72 HOURS IN ADVANCE TO SCHEDULE FOR CEItTIFICATE OF COMPLETION INSPECTION @ 330-5673** "NOTE" BUILDING PERMIT REQUIRED FOR ANY CONSTRUCTION ABOVE **CA i N -11 A- j__,q(j() A 77 GRADE ,70 PRIM TO DIGGING" 48 HOURS BEFORE YOU DIG Revision 0/5198 CALL SUNSHINE 1-800-432-4770 IT'S THE LAW IN FLOR117A - __r_1 'OWNER: AGENT: ilding Performance Method for Commercial Buildings Form 400A-97 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs FLA/COM-97 Version 2.2 NAME_COMMUNITY NAT. BANK BRANCH_ PERMITTING OFFICE: _413 W. FIRST STREET _Sanford _SANFORD, FL 32771 CLIMATE ZONE: _5 _COMMUNITY NATIONAL BANK PERMIT NO: _PENDING JURISDICTION NO:_691500 BUILDING TYPE: _Business (Office) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building .CONDITIONED FLOOR AREA: _1940 NUMBER OF ZONES: 1 'MAX. TONNAGE OF EQUIPMENT PER SYSTEM: 5 COMPLIANCE CALCULATION: METHOD A DESIGN CRITERIA RESULT ----------------- -------------- ------ A- WHOLE BUILDING 86.41 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING EXTERIOR LIGHTING 560.00 560.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 10.00 PASSES HEATING EQUIPMENT 1. Et 10.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Unconditioned Space 6.50 4.20 PASSES REHEAT SYSTEM TYPES USED ELECTRICAL SYSTEM .WATER HEATING EQUIPMENT ' 1. EF 15.00 0.88 PASSES ' PIPING INSULATION REQUIREMENTS 1. Non -Circulating s 1.50 1.42 PASSES ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: 'I hereby certify that the plans and specifications covered by this calcu- lation are in co ianQe with the .Florida Ene f'cienc e. PREPARED B DATE: I hereby certify that.thi building in compliance wi he' Irid Ene Efficiency Cod OWNER/AGENT: Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, Flo S. BUILDING OFFICIAL: DATE: 6- l - -6 1-01 reby certify(*) that the system design is in compliance with the Florida gy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE FIGHTING ITECT < ANICAL:BINGTRICAL: (*) Signature is required whe a Florida law requ res design to be performed by registered design professi nals. Typed names and registration numbers may .be used where all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLI1 CF ------GLAZING--ZONE 1 ----------------------------------------------- ation Type ---U SC VLT Shading------- Area(Sgft) f--------------------- ---- -------------- th Commercial 1.31 .85 .95 Continuous Ove 38 Guth Commercial 1.31 .85 .95 Continuous Ove 17 est Commercial 1.31 .85 .95 Continuous Ove 11 Total Glass Area in Zone 1 = 66 Total Glass Area = 66 402------- WALLS --ZONE 1 ------------------------------------------------ Elevation Type U Insul R Gross(Sgft) ----------------------------------------- ----- ------- ----------- North 4"Brick/8"CMU/3/4"ISO Btwn 24"oc 0.142 16 600 South 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 12 600 East 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 12 323 West 8"CMU/3/4"ISO Btwn 24"oc/5/8"Gyp 0.151 12 323 Total Wall Area in Zone 1 = 1847 Total Gross Wall Area = 1847 403------- DOORS --ZONE 1 ------------------------------------------------ Elevation Type U Area(Sgft) --------------------------------------------------- ----- ---------- North 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 42 South 1-3/4 Steel Door-Fiberglass/Mineral woo 0.60 21 Total Door Area in Zone 1 = 63 Total Door Area = 63 404------- ROOFS --ZONE 1 ------------------------------------------------ Type Color U Insul R Area(Sgft) Shngl/1/2"WD Deck/WD Truss/6"Ba Light 0.040 19 1940 Total Roof Area in Zone 1 = 1940 Total Roof Area = 1940 405.------FLOORS-ZONE 1------------------------------------------------- T pe Insul R Area(Sgft) Slab on Grade/Uninsulated 0 1940 Total Floor Area in Zone 1 = 1940 Total Floor Area = 1940 406------- INFILTRATION -------------------------------------------------- ICHECK Infiltration Criteria in 406.1.ABCD have been met. NCE [ECK -v- MECHANICAL SYSTEMS CHECK ------------------------------------------------------------ ---- --- -VAC load sizing has been performed. (407.1.ABCD) 407.------COOLING SYSTEMS----------------------------------------------- --- Type No Efficiency IPLV Tons ---------------------------- ------------- ------------------- 1. Split System 1 10 11 4.83 408.------HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr -------------------------------- --------------------------- 1. Electric Resistance 1 10 60000 409.------VENTILATION --------------------------------------------------- --- I CHECK Ventilation Criteria in 409.1.ABCD have been met. -AIR DISTRIBUTION SYSTEM ----------------------------------------'i CHECK' - ------------------------------------------------------- ------ ;Duct sizing and design have been performed. (410.1.ABCD) VAHU Type Duct Location R-value'. r--------------------------------------------------------- ---- Air Conditioners Unconditioned Space 6.5 CHECK r ------------------------------------------------------ ---- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. I PLUMBING SYSTEMS 411.-----PUMPS AND PIPING -ZONE 1 --------------------------------------- Type R-value/in Diameter Thickness --------------------------------------------------- 1. Non -Circulating 3.2 1.5 1.5 412.-----WATER HEATING SYSTEMS -ZONE 1 ---------------------------------- Type Efficiency StandbyLoss InputRate Gallons 1. <=12 kW 15 0 30 40 ELECTRICAL SYSTEMS CHECK 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- ---- Metering criteria in 413.1.ABCD have been met. 414------ MOTORS --------------------------------------------------- ----- Motor efficiencies in 414.1.ABCD have been met. 415------ LIGHTING SYSTEMS -ZONE 1 --------------------------------------- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) ---------- ----------------- ----------------- --- ------ ---------- Customer A 1 Stepped-3 Leve 4 None 0 5280 1940 Total Watts for Zone 1 = 5280 Total Area for Zone 1 = 1940 Total Watts = 5280 Total Area = 1940 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ------------------------------------------------------------------------ SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 Plans Review Sheet Date: 6/8/01 Business Address: 413 W. I" St. Occ. Ch. 26 Business Name: Community National Bank Ph. Contractor: Spolski Const. Ph. (407) 322-8424 Reviewed [ ] Reviewed with comment [ X ] Rejected Reviewed by: H. A. "Pete" Tucker, Fire Protection Inspector Comment: Plans reviewed as Business Occupancy. Fl) reserves right to require applicable code requirements if occupancy use changes. 1.1 Application — New Building. Type V Const., 1820 sq.ft. 1.2 Mixed — N/A 1.3 Special Definitions — N/N 1.4 Classification of Occupancy — Business 1.5 Classification of Hazard of Contents — Ordinary 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — O.K. 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — O.K., will field verify 2.8 Illumination of Means of Egress — O.K.; will field verify 2.9 Emergency Lighting — O.K.; will field verify 2.10 Marking of Means of Egress — O.K.; will field verify 2.11 Special Features — N/A 3.1 Protection of Vertical Openings — N/N 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "B" (Offices class "C") 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 3.4 Detection, Alarm and Communications Systems — N/A 3.5 Extinguishing Requirements — as per NFPA 10 3.6 Corridors — N/A - 4 Special Provisions - 5 Building Services 5.1 Utilities — as per LSC 7-1 5.2 HVAC — as per LSC 7-2 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: N/A Monitoring: Required by a U.L. listed Central Station for all mandated fire sprinklered properties Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: building has fire sprinkler system. 3-6.1 Key Box — N/A 3-7.1 Bldg. Address Number Posted and Legible — Required; will field verify 0 WEATHER HEAD — (1) 2' CONDUIT W1 (3) 3/0 CU, 200 A. I PHASE METER SOCKET O "4 CARD. (2) GRD. RODS FOOTER STEEL (1) 2' CONDUIT W1 (3) CU. 4 (1) "(o GRD. EXTERIOR INTERIOR SERVICE DROP I I 200 A. 1 PHASE NEMA 3R FUSED 200 A. 1 PHASE DISCONNECT 42 CKT. PANEL M.L.O. IF4 a a Z� W OO a !g -J ZU- 0 w Um� w W CL FILE HBANKIaS DATE: 26 APR 2001 DRAWR J.T.R. SCALE: DRAWN. FILE: WASTE WATER DIAGRAM J.T.R. HBANK,a4 white heart designs COMMUNITY NATIONAL SCALE: DATE- Terry M. Lodge BANK OF MID-FLORIDA '17" I'-0' 26 APR 2001 PERMIT � FiEBlE7ENTIAL F�E81dNER a co w 0 co � 0 3" VTR. �I r Jo Z I\ �W iW 2" 1 I II I 2" VTR. I 12" JI I W/C S INK 3 SINK 2" SINK 12° In W/C I1z 4 Q OO 2" C.O. 2" W 2 BUILDING LINE z Z) O ' C) 4" 2-WAY G.O. TEE W SLEEVE NSANKIaS TNROUGN FOOTER DATE 26 APR 2001 TO SEWER DRAW J.T.R. SCALE