HomeMy WebLinkAbout3500 Sanford Ave 24476 Electrical Load calc, revisions needed Father Flanagan's boys town350o SRNFom Ap
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Section 9 Compliance Program --Residential Point System Method
Version 2.0 January, 1989
Department of Community Affairs
Printout generated by EPI89 and submitted in lieu of Form 900-A-89
THIS COMPLIANCE FORM IS VALID IF SUBMITTED BEFORE JANUARY 1, 1990
-------------------------------------------------------------------------------
PROJECT NAME:J 6 � A- , jj. PERMITTING OFFICE:
AND ADDRESS: rd
CLIMATE ZONE: 4 6
BUILDER: PERMIT NO.:
OWNER: JURISDICTION NO.: Z,-q /S00
-------------------------------------------------------------------------------
BUILDING OFFICIAL
COMPONENT VALUE CHECKLIST
STRUCTURE TYPE:
Single -Family
PREDOMINANT EVE OVERHANG
Length:
2.00
PORCH OVERHANG
Length:
2.00
WINDOWS
Single Clear
Total Area:
348.0
WALLS
1. Ext NormWtBlock Int
Area:
2832.0
R-Value:
3.0
DOORS
1. Ext Wood
Area:
84.0
2. Adj Wood
Area:
21.0
CEILINGS
1. FLAT Under Attic
Area:
2640.0
R-Value:
19.0
FLOORS
1. Slab -on -Grade
Perim:
204.0
R-Value:
0.0
DUCTS
In Cond. Space
Length:
ALL
COOLING
1. Central A/C
SEER:
8.00
Multizone:
Credit
HEATING
1. Strip Heat
STRIP:
1.00
Multizone:
Credit
HOT WATER
Bedrooms:
8
1. Electric
EF:
0.89
INFILTRATION
Practice:
2
Conditioned
Floor Area:
5216.0
AS BUILT POINTS
/ BASE POINTS
94041.2 107289.5
* 100 = EPI
87.7
M
----------------------------------------
In Accordance with Sec. 553.907 F.S.,
I Hereby certify that the plans and
specifications covered by this calcu-
lation are in compliance with the
Florida Energy Code.
OWNER/AGENT:
DATE:
----------------------------------------
Review of the plans and specifications
covered by this calculation indicates
compliance with the Florida Energy
Code. Before construction is completed
this building will be inspected for
compliance in accordance with Section
553.908 F.S.
BUILDING OFFICIAL:
DATE • //-,2 74 i
SUMMER CALCULATIONS
BASE __= I AS -BUILT
GLASS ------------
ORIEN
AREA
x BSPM =
POINTS
I TYPE SC
ORIEN
AREA
x SPM
x SOF
= POINTS
-------------------------------------------------------------------------------
E
114.0
102.0
11628.0
SGL
CLR
E
99.0
109.2
0.87
9357.3
SGL
CLR
E
15.0
109.2
0.93
1517.9
S
120.0
90.9
10908.0
SGL
CLR
S
30.0
100.2
0.79
2381.4
SGL
CLR
S
30.0
100.2
0.89
2667.6
SGL
CLR
S
30.0
100.2
0.91
2740.8
SGL
CLR
S
30.0
100.2
0.93
2801.0
W
114.0
102.0
11628.0
SGL
CLR
W
99.0
109.2
0.87
9357.3
SGL
CLR
W
15.0
109.2
0.93
1517.9
-------------------------------------------------------------------------------
.15 x COND. FLOOR /
TOTAL GLASS
= ADJ. x
GLASS =
ADJ GLASS
GLASS
AREA
AREA
FACTOR
POINTS
POINTS I
POINTS
-------------------------------------------------------------------------------
.15 5216.0
348.0
2.248
34164.0
76810.1 I
32341.3
AREA x BSPM
= POINTS
I TYPE R-VALUE
AREA
x SPM =
POINTS
-------------------------------------------------------------------------------
WALLS-----------
Ext 2832.0 1.00
2832.0
Ext NormWtBlock Int 3.0
2832.0
1.40
3964.8
DOORS -----------
Ext 84.0 4.80
403.2
Ext Wood
84.0
7.20
604.8
Adj 21.0 1.60
33.6
Adj Wood
21.0
2.40
50.4
CEILINGS----------
UA 2640.0 0.60 1584.0
FLOORS ----------
Slb 204.0 -31.80-6487.2
Under Attic
19.0
2640.0
1.10
2904.0
Slab -on -Grade
0.0
204.0
-31.90
-6507.6
INFILTRATION ---------
5216.0 10.90 56854.4 1 Practice #2 5216.0 10.90
56854.4
TOTAL SUMMER POINTS
132030.1 I 90212.
TOTAL x
SYSTEM
= COOLING
TOTAL
x CAP x
DUCT x
SYSTEM x
CREDIT =
COOLING
SUM PTS
MULT
POINTS
COMPON
RATIO
MULT
MULT
MULT
POINTS
----------------------
132030.1
0.43
56772.9
-------------------------------------------------
190212.1
1.000
1.000
0.430
0.900
34912.
*******************************************************************************
WINTER CALCULATIONS
BASE ___
__=
AS -BUILT
GLASS ------------
ORIEN AREA x BWPM
= POINTS
TYPE
SC
ORIEN
AREA
x WPM
x WOF =
POINTS
-----------------------
E 114.0 -5.6
-638.4
--------------------------------------------------
SGL
CLR
E
99.0
-2.2
0.27
-59.8
SGL
CLR
E
15.0'
-2.2
0.60
-19.8
S 120.0 -14.0
-1680.0
SGL
CLR
S
30.0
-10.9
0.85
-277.9
SGL
CLR
S
30.0
-10.9
0.93
-305.1
SGL
CLR
S
30.0
-10.9
0.95
-311.0
SGL
CLR
S
30.0
-10.9
0.96
-314.6
W 114.0 -5.6
-638.4
SGL
CLR
W
99.0
-2.2
0.27
-59.8
SGL
CLR
W
15.0
-2.2
0.60
-19.8
-------------------------------------------------------------------------------
.15 x COND. FLOOR
/ TOTAL GLASS
= ADJ. x
GLASS =
ADJ GLASS I
GLASS
AREA
AREA ,
FACTOR
POINTS
POINTS
POINTS
-------------------------------------------------------------------------------
.15 5216.0
348.0
2.248
-2956.8
-6647.7 I
-1367.9
AREA x BWPM = POINTS I TYPE R-VALUE AREA x WPM = POINTS
------------------------------------------------------------
-------------------
WALLS-----------
Ext 2832.0 1.10
DOORS -----------
Ext 84.0 5.10
Adj 21.0 4.00
CEILINGS----------
UA 2640.0 0.60
FLOORS ----------
Slb 204.0 -1.90
3115.2
Ext NormWtBlock Int 3.0 2832.0
428.4 I Ext Wood
84.0 Adj Wood
1584.0
-387.6
Under Attic
Slab -on -Grade
3.80 10761.6
84.0 7.60
21.0 5.90
19.0 2640.0 1.00
0.0 204.0 2.50
638.4
123.9
2640.0
510.0
INFILTRATION ---------
5216.0 4.10 21385.6 Practice #2 5216.0 4.10 21385.6
TOTAL WINTER POINTS
19561.9 I 34691.6
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TOTAL x
SYSTEM
= HEATING
TOTAL
x CAP x
DUCT
x SYSTEM
x CREDIT
= HEATING
WIN PTS
MULT
POINTS I
COMPON
--------------------------------------------------
RATIO
MULT
MULT
MULT
POINTS
---------------------------
19561.9
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
1.14
22300.6
134691.6
1.000
1.000
1.000
0.900
31222.5
*******************************************************************************
WATER HEATING
*******************************************************************************
BASE ___ __= AS -BUILT
NUM OF x MULT = TOTAL I TANK VOLUME EF TANK x MULT x CREDIT = TOTAL
BEDRMS RATIO MULT
----------------------- --------------------------------------------------
8 3527.0 28216.0 I 40 0.89 1.000 3488.3 1.00 27906.7
*******************************************************************************
SUMMARY
*******************************************************************************
BASE __= I =_= AS -BUILT
COOLING HEATING HOT WATER TOTAL I COOLING HEATING HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS POINTS + POINTS + POINTS = POINTS
-------------------------------------------------------------------------------
56772.9 22300.6 28216.0 107289.5 134912.1 31222.5 27906.7 94041.2
*****************
* EPI = 87.7
*****************
A. J. Electric
Residential • Licensed • Commercial 7662 Jester Court
Orlando, Florida 32807
(407) 678-3073
Cr>Nn,ec�ek ua- &S
StS-ta_ sa� I.C, kao w
Z- �S�U�f1t�ne�
1 Club u�
LU
�5 GAL
A 2� ti s�e4?S�
-3168OU3
D
A- f6A+ (A k
CRLCUCA-IAAC.owtiPkL.nad EIS; ikrhPS,
p
NCARB Certificate Holder
October 27, 1989
Richard A. Cohen
Fire Marshall
1303 S. French Ave.
Sanford, Florida 32771
Re: Residential Living Units for Father Flanagan's Boys Town
Dear Mr. Cohen:
Per our conversation on October 26, 1989, pertaining to your preliminary
review of the referenced construction documents, the following is submitted as
an addendum to same.
1) A automatic fire suppression system per NFPA-96 shall be installed in the
exhaust hood over the kitchen range/oven.
2) The existing bed room doors shall be removed and replaced with 1-3/4"
solid core wood doors with closers.
3) Emergency lights shall be installed in the new hallways and opposite
exterior exits per item #27 on sheet A-7.
4) Smoke detectors shall be installed in all bed rooms as shown on first
floor plan, sheet A-6, in kitchen and in multi -purpose room on second
floor. See referenced symbol on A-7.
5) A fire alarm system shall be installed per sheet A-6 on both floors. FA
indicating alarm and P.S. FA indicating pull station.
6) Fire extinguishers shall be installed per your direction.
7) All interior finishes are existing painted gypsum wall board and should
meet class "A" finish requirements.
8) The new vinyl composition tile and carpet shall meet the class 1-SBC
requirements and so be certified by the general contractor.
9) A 2'6" X 6'8" X 1-3/4" solid core wood door with closer and latchset
shall be installed at the new interior stairwell on the first floor.
Please contact me if you have further questions and/or requirements for
approving this project.
qY truly s.
David J. Moore, AIA
cc: Boys Town
P.O. BOX 2414 WINTER PARK FLORIDA 32789 305-629-2996