Loading...
HomeMy WebLinkAbout104 Park Ave 12629 Interior remodel"y;jt'/F'Ahr.%rw+nnwat:•.. .�....rwr.+n.... Iir,jI/l l._,�C'«.. log IY TO: FROM: DATE: RE: CA,1rYMANN DRACA S I-4 ASSOCINI-11".S ARCS [I'I�L�CA'FS PLANNERS, INCA. POST OFFICE DRAWER 938 SANFORD, FLORIDA 32771 TELEPHONE 305-322-5472 WINTER PARK 305-631.6067 MEMO Dr. Vincent Roberts Mr. John Kader Mr. Fred H. Williams Carl 0.' Gutmann, Jr. 20 April 1977 Fire classification for joint tenant stair between Roberts Kader Building and Williams Building at First Street and Park Avenue, Sanford, Florida. 1. Separating walls between Roberts Kader building and joint stair 16" solid masonry from first floor through the roof. Wall classifi- cation one hour or better. 2. Separating walls between Williams building and joint stair 16" solid masonry from first floor through the roof. Wall classification one hour or better. 3. Openings from building area into the joint stair to be Glass "C" or better to provide equivalent one hour separation. 4. Existing openings in joint stair walls to be reduced to standard 31--0" x 6'-8" size with 2 x 4 wood stud framing and 5/8" fire code gyp board on both sides. Install standard hollow metal frame with class TIC" rated wood door in 3'-0" x 6'-8" opening. Carl 0. Gutmann, Jr. AIA COGjr/dkw 5UITE A00 SANFORD ATLANTIC NATIONAL BANK BUILDING MEMOERS OF THE AMERICAN INSTITUTE OF ARCHITECTS