HomeMy WebLinkAbout3090 Orlando Dr Load 19938 Calc1 4 t - FLORIDA MODEL ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION l SECTION 5 BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH ADMINIS?'IcRED BY THE DEPARTMENT OF COMMUNITY AFFAIRS CODES AND STANDARDS SECTION STATISTICS: RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS PROJECT NAME: EMPIRE BANK ADDITION JURISDICTION: ADDRESS: CITY, ZIP CODE: Sanford JURISDICTION NO. BUILDER: h ( w2' i 00 ZONE: `i OWNER: E e. OA m e CCU p .r BUILDING CLASS IFICATION(SI: BUILDING VALUE: S 7 Ooo BUILDING INFORMATION COMPONENT. R-VALUE OF INSULATION ONLY AREA WALLS CBS X FRAME OTHER R- 3.75 1274 . GROSS AREA CBS FRAME OTHER R- 1464 GLASS CLEAR TINTED (o SC- 186 ROOFICEILING WOOD © CONCRETE OTHER_—. R- 25 1624 FLOOR OVER UNCOND. SPACE WOOD CONCRETE OTHER R- . 0 SYSTEM INFORMATION AIR CONDITIONER EFFICIENCY EER/COP- 8.4 HEATING SYSTEM TYPE STRIPE] HEAT PUMP GAS ® OIL [j SOLAR HEATING SYSTEM EFFICIENCY EER/COP- 2.5 HOT WATER SYSTEM TYPE ELECTRIC HT. REC. GAS OIL SOLAR UACTUAL- . 20 OTTVACTUAL- 11.7 VALLOWABLE- 37 OTTVALLOWABLE- 30. 3 CERTIFIED BY: DATE: 1212 83 COMMERCIAL ENERGY CODE'COMPLIANCE CHECKLIST FOR BUILDING -DESIGN BY .COMPONENT PERFORMANCE APPROACH: C,' BE FILED..WITH BUILDING PERMIT APPLICATION CODE; TYPICAL WALL AND CEILING SECTIONS SHALL'SUPPLEMENT, THIS COMPLIANCE THIS FORM BUILDING VALUES BUILDING INFORMATION GROSS SQUARE FEET CONDITIONED/HEATED FLOOR SPACE 1624 WALL AREAS: TOTAL OPAQUE AREA - Aw. 1234 TOTAL GLASS AREA Ag. 186 I TOTAL DOOR AREA - Ad 40 GROSS WALL AREA (TOTAL OF ABOVE) - A 1.460 ROOF AREAS: TOTAL OPAQUE AREA - Aw 1624 TOTAL -SKYLIGHT AREA Ag - U VALUE CALCULATION UW U OF OPAQUE -AREA = .14 Ug= U OF GLASS AREA = _5 7 U3= U OF DOOR AREA _ _59 Uo= U OF OVERALL:i "WALL/GLASS/DOOR = _20 Uw U OF CEILING ROOF AREA =_n4 Ug= U OF SKYLIGHT AREA. _ - Uo= U OF OVERALL CEILING/ROOF _ Uo= U OF FLOOR OVER UNHEATED SPACE NOTE: SUPPLEMENTAL INFORMATION IS NECESSARY TO SHOW TRADE-OFF BETWEEN CEILING/ROOF ASSEMBLY AND WALL/ GLASS/DOOR ASSEMBLY -OVERALL U VALUES. CIV CALCULATIONS UwAWTDeWALLCONDUCTIONCOMPONENT.- UfAf6t GLASS CONDUCTION COMPONENT = A n .37* 4 46 over 3 storyl i i t = SUMMER DESIGN DRY BULB - 780) ` From SECTION 302.1(b) Af SF SC GLASS RADIATION COMPONENT._ A = -=- j NOTE: FOR GLASS, NOT EQUAL WALL p SIDES, SUBSTITUTE FOR RADIATION COMPONENT ABOVE, THE ORIENTATION RADIATION COMPONENTS. GLASS ORIENTATION' N _ 1.58 RADIATION COMPONENT NW/NE - FOR EACH DIRECTION' E/W = 5.49 SE/SW = Af OSF SC S = A 30.3 i OVERALL OTTV '.( SUM OF COMPONENTS) 11.71 GLASS MFR. & MODEL # INTERIOR SHADING DEVICE I Page 1 i i 3 LyMMERC IAL CONTINUED: WINDOW AND DOOR INFILTRATION. WINDOW INFILTRATION RATES 5 WINDOW MFR.. & MODELA DOOR INFILTRATION RATES Table 5-3 DOOR MFR. & MODEL # MECHANICAL SYSTEMS REHEAT COMPLIANCE WITH CODE (503.3) HVAC EQUIPMENT PERFORMANCE Tables 5-4,5-5, EER`OR COP (UNDER 65,000 BTU/HR.) 8.4 7.5 EER OR COP (65,000 BTU/HR. AND OVER) MFR. & MODEL f Weatherking RH44-3B AIR TRANSPORT FACTOR 8.0 CHECK HVAC CONTROLS FOR COMPLIANCE sect. DUCT SYSTEM INSULATION R VALUES 4 34 R-at 15 PIPING INSULATION.THICKNESS i 1/211 Table 5-9 ; r CRVICE WATER HEATING NOT REQUIRED CHECK PERFORMANCE EFFTCIENCY a 5G4.2 SWIMMING POOL CONTROL COMPLIANCE 504.2 (b) 3 CONSERVATION OF HOT WATER SHOWER FLOW RATE 3 GPM LAVATORIES (PUBLIC) FLOW LIMITED TO 0.5 GPM OUTLET TEMPERATURE ELECTRICAL POWER AND LIGHTING (NON-RESIDENTIAL) a CHECK COMPLIANCE OF: POWER FACTOR CORRECTION. sect. 505.2 VOLTAGE DROP LIGHTING SWITCHING METERING (INDIVIDUAL) LIGHTING,BUDGET NOTE: FIXTURE SCHEDULE SHALL;INCLUDE NUMBER AND WATTAGE OF EACH FIXTURE WITH TOTAL WATTAGE 1.5w/ftz I OF THE BUILDING. I FACADE LIGHTING AS PERCENT OF BLDG. a - 1% 2% e i CII: CERTIFY THAT THIS BUILDING COMPLIES WITH THE ENERGY CODE. i I Page 2