Loading...
HomeMy WebLinkAbout201 W 1st St 16090 Plans Remodel Sem. Mental Hlth Cntr- ANDREW KUTZ - ARCHITECTS 9/18/81 Building Official City of Sanford Sanford, Florida 32771 Subject: 201 West first St. Suite 102 AEGIS (Seminole County Mental Health Center Inc.) Clear Mr. Wynn: I have inspected the above referenced locAtion regarding occupancy separation construction and find that: The demising wall to the west is 811 concrete or concrete block backed up by a similar wall on the exterior of'A.the abutting building which provides a 3 hour fire resistance rating accourding to.S. STD. BLD Code Appendix B table 3 page B-11. Similarly, the Eastern wall between the space and adjacent corridor appears to be 811 concrete block with a gypsum finish on both sides which according to "Appendix B" constitutes a 2 hour or more fire rating. The ceiling/floor structure above this space appears to be of varied types of construction including concrete on metal deck and wood floor over wood joists, with a suspended acoustical the ceiling over the entire space. Of this construction that which appears to be the lesser of resistance ratings .does seem to comply with Appendix B Table 7 Item D, page B45 for a one hour rating - however the ceiling tile has not been established non-combustible and there do seem to be a few minor broaches where the floor system has not been completely draft -stopped. In view of the continued use of this space as a separate occupancy within this building over the past number of years, and the con- struction observed (noted previously) it is assumed there is the one hour required separation between this space and those above. The North and South walls of this space are exterior non -abutting walls and do not therefore require rated construction for occupancy separation. Since- ely yo , Andrew Kutz, AK;aj cc: John Nestor (AEGIS) 1.3-alint Construction 2004 FRENCH AVE ,SANFORD.FLA 32771 (305)323.8746 i ,. , _ a �. J 4Z,4, is all j 112 161