Loading...
HomeMy WebLinkAbout1403 Medical Plaza Dr 19324 Plans New medical officeB.O. 3RUNING 44 142 57188 REFLECTED CEILINGPLAN'. FLOOR FLAN SUITE .106 0 51 LEGEND. LAY -IN LIGHT FIXTURE CEILING MOUNTED LIGHT FIXTURE EXIT LIGHT �p DIFFUSER ® EXHAUST FAN �E-L--' EMERGENCY LIGHTING 0 �■ 4 ►4 r_ AA_ I A7 V7i RR o NTS EXAM ROOM A C LOSET 102 '31zl"ADJU5TABLE' SHELVE STAIJDARDS ARE TO-. BE FLUSH MOUNTED ON SIDE L �I ELECTRICAL` TELEPHONE OUTLETS II'_0„ J C OFFICE 10Ca U. C. REFRIG. r- Q I i = = m G ADJUSTABLE 2�4" SHELVES, IZ' ,DEEP, PLASTIC LAMINATE OH ALL ' SURFACES . I I -- 0„ j el A OFFICE 105 N N 9" RADIUS BOTH SIDES m END OPEN PANELCop N » J 5,_ 0„ 0 LAB III F LAB III LAB III U. C. LIGHT OPEN TO CORK. 10'-5 „ PASS WINDOW PASS -THRU STAINED WOOD SHELF STAINED WOOD SHELF KNEE END SPACE 'cv PANEL PI BUSINESS OFFICE 109 AiBUSINESS OFFICE 109 NOTES L ALL DIMENSIONS ARE TO BE VERIFIED IN FIELD. 2. ALL O.FE. IS TO BE VERIFIED WITH OWNER. 3. CASEWORh IN EXAM ROOMS, CLOSET 102, AND LAB II I,' IS TO BE PLASTIC LAMINATE ON ALL EXPOSED SURFACES; COLORS TO BE `SELECTED BY .OWNER. 4. CASEWORK IN OFFICES 105 E IUG AND t:5U MESS OFFICE 109 15 TO BE STAINED WOOD FINISH; COLORS TO BE SELECTED BY OWNER. 5. PROVIDE CABINET HARDWARE SAMPLES FOR APPROVAL BY OWNER. 0,�MFfF 7 GRESHA, SMITH AND PANERS DOOR A i V DFRAME SCHEDULE. DOOR SYMBOL DOOR FRAME FIRE RAT'G LABEL HARDWARE REMARKS SIZE, WIDTH HEIGHTI THICK MA7 TYPE GLASS UNDER CUT MAT TYPE DETAILS SET NO. KEYSIDE SPACE SPACE MARK JAMB HEAD SILL 100 A 3'-0" G'-8" I3iq" 1n/ F - HM 101 A 3'-O" G'-8,, 1 3/4" F - HM 101 B E'- O„ G'- 8„ 1 3/4 „ W F - H M 104 A 3'-0" (o'-8" 1 1344" W F - HM. 105 A 3'-0" Cc`8" 13/4" W F - HM 10 & A 3,- 0„ (o,-8., 1 3/4„ W F - HMI 107 A 5,-0,, G.-8" 1 3/4" W F _ HM 108 A . 3'-0„ Co._8„ 1 -Y4" W F - HM 109 A 3'-0" G'- 8"1 1 4'4" W F - " HM III A 2'-G,, S., 13iq" W F - HM 113 A 3'-0" &-8'' 1 24" W F - HM 115 A 2,- Cam 1 3/4'' W F - H M DOOR LEGEND W. WOOD - STAINED HM. HOLLOW METAL F GRESHAM, SMITH AND PARTNERS FINISH SCHEDULE SPACE FLOOR BASE WALLS CEILING ACSY SE7 NO. REMARKS _ NUMBER NAME MAT COL MAT C.OL NoritN soutH EAST WEst MAT COL MAT COL MAT COL MAT GOL MAT COL 100 WAITING A B B B 13 B 101 EXAM C B B B B B 102 CL05ET C B J J J J 103 TOILET C B B B B B 104 EXAM C B B B B B 105 OFFICE A B B B B B IOCo OFFICE A B B B B B 107 EXAM C B B B B B 105 EXAM C B B B B B 109 BUSINESS OFFICE A B B B b B 110 COR K C B B 5 B B III LAB C B B B B B 112 CORR. C B B B B B — 113 TOILET. C B B B 15 B 114 CLOSET C 15 J J J J 1 1 5" CORR. C B B B B B FINISH AND r,0L ?R LEGEND FLOOR BASE WALLS CEILING WAINSCOT A. Carpet'.' arpet" A. Carpet A. Carpet A. Lay -in 2 x 4 A. Carpet B. Vinyl Asbestos B. Rubber B. Vinyl #1 B. Lay -in 2 x 2 B. Marble C. Sheet Vinyl C. Vinyl C. Vinyl #2 C. Concealed Spline C. Vinyl D. Conductive D. Conductive D. Vinyl (w/iedlar)' D. Drywall -Paint D. Epoxy E. Quarry Tile E. Quarry Tile E. Quarry Tile E. Drywall -Epoxy E. Quarry Tile F. Ceramic Tile F. Ceramic Tile F. Ceramic Tile F. Plaster -Paint F. Ceramic Tile G. Brick Pavers G. Brick G. Brick G. Ceramic Tile G. Brick H. Terrazzo Fl. Terrazzo H. Paint (Enarnel) H. Exterior Drywall H. Paint J. Wood J. Wood J. Paint (Latex) J. Stucco J, Paneled K. Existing K. Existing K. Paneling K. Wood K. Existing L. Exposed L. Exposed L. Existing;. L Existing L. Exposed M. Glazed Tile M. Glazed Tile M. Exposed M. Exposed M, Glazed Tile N. Concrete Sealer N. Sheet Vinyl N. .Glazed Tile N. Cement Abestos N. Plastic Laminate O. Rubber O. Paint O. 'Plastic Laminate O. Metal Clad Panels O. Plaster P. Traffic Bearing P. Slate P... Epoxy Q. Slate, Q, Waterproof Q..Plaster R. Waterproof Coating Coating. R.:-Paper S. , Radial Rubber Z. Solid Vinyl S. Textile Walicovering _ T. Solid .Vinyl Tile T. Acoustical Wallcovering U. Fabric Wrapped Panels U_ cc Z Z Z 0 ca U O ° O a � v •j i Co Z 2 tCS CCS C _v Ul (t E Ln •C: CC E LD C: L ®' C� t�3 a coo ti C: v Ce CE J w a 0 a Z 0 w LC o 1 Li I I I i CASEWORK SCHEDULES A3'01k' FILE 63307 DArE 711. 1. 318 3 ti r f BRUNING 44-142 57188 LL 'Q a ► z y . m o w 'o 0 a �.r MECHANICAL SPECIFICATIONS } CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE, OPERATIONAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEM IN ACCORDANCE WITH DRAWINGS. 2 ALL WORK SHALL BE FIELD COORDINATED AND DIMENi 3 SIONED. ROUTING OF DUCTWORK, DIFFUSERS, REGIS- TERS, ETC. SHALL BE COORDINATED WITH LIGHTING, a f CABINETS, ETC. i i • UNLESS'OTHERWISE NOTED, CONTRACTOR SHALL OBTAIN AND PAY ALL REQUIRED PERMITS AND INSPECTION FEES. INSTALLATION AND PRODUCTS SHALL COMPLY WITH ALL STATE, LOCAL AND HEALTH DEPARTMENT CODES, BUILDING ' CODES, APPLICABLE LIFE SAFETY CODE, AND STATE AND LOCAL., ORDINANCES. DUCTWORK INSULATION SHALL COM A - PLY WITH NF'PA 90A AND 90B. ALL EQUIPMENT SHALL BE EXAM EXAM U.L. LISTED AND INSTALLATION SHALL COMPLY WITH L- 107 I I 108 1 U.L. STANDARDS WHERE APPLICABLE. 11 ALL WORK AND EQUIPMENT SHALL BE GUARANTEED FOR ONE 1 1 _ YEAR FROM THE DATE OF FINAL ACCEPTANCE. COMPRES- FENN ZEFHY2 // �T 1 SOR SHALL BE WARRANTED AN -ADDITIONAL 4 YEARS. / ALL DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ® THE LATEST EDITION OF SMACNA LOW VELOCITY DUCT OFFICE \ < / 01A scD BUSINESS CONSTRUCTION STANDARDS, 24 GAUGE MINIMUM. ALL 106 IQ/2L� D ''' �\ V� `f J / H CFM II OFFICE LONGITUDINAL JOINTS SHALL BE TAPED WITH 2 WRAPS OF i s ZIS CFM i ( M �y 1--, r--, -8 `1' 109 "HARDCAST" HEAVY DUTY DUCT TAPE. FLEXIBLE DUCT F, III loll$ i L SHALL BE WIREMOLD TYPE WGC AND SHALL NOT EXCEED 4 M L__J FEET IN LENGTH. WHERE SHOWN, RIGID ROUND DUCT II it 2GbO CFM C ��I SHALL "BE RUN BETWEEN MAIN AND FLEX DUCT. 10 xJ IN SOFFIT �" ANEMo5TAT LEX. CGN . _ 113 7i1711 SPIN -IN FITTINGS WITH MANUAL VOLUME DAMPERS MODEL X�HD (TYFI (M.V.D.) SHALL BE USED AT ROUND DUCT TAKE -OFFS. i` ) Il�xla 0- 12x1� � � M I 112 WHERE DIFFUSERS ARE SHOWN TAPPED INTO RECTANGULAR ^ b DUCTS'.` ;41_ lollI�-INIw/Pi-\Mf E� CEILING DIFFUSERS SHALL BE EQUAL TO ANEMOSTAT TYPE j X I�jXIL� �''-• 4- �I�X PDL WITH OPPOSED BLADE DAMPERS. RETURN GRILLE S'HALL'BE EQUAL TO ANEMOSTAT MODEL XRC3HD-81. WITH CORR II AQEMGY�TAT MODE I011� 1" T.A. FILTER. EXHAUST GRILLES SHALL BE EQUAL TO I 115 8� X12C .�-1D-8I 2�X ANEMOSTAT MODEL RCGC50. ALL DIFFUSERS AND GRILLES 7i1� T WOO CFM W�FILT LAB lO/Z4 SCD C ORR SHALL HAVE BAKED ENAMEL OFF-WHITE FINISH. • 2ox ---- 111 37SCFM ALL DUCT DIMENSIONS SHOWN ARE I-NSIDE CLEAR UNLESS 71I+ ESS r , OTHERWISE SPECIFIED. DUCTS SHALL BE EXTERNALLY WRAPPED WITH 1-•1/2" FIBERGLASS FLEXIBLE DUCT INSULATION WITH VAPOR BARRIER UNLESS .OTHERWISE AUX. Di2A10 FA1A D 11 SET _ 8 2� SC I�CF� INDICATED. . COI DE NSAT � D2 I I I , SEE SFECS. ' 81�� HVAC UNIT'SHALL BE SPLIT SYSTEM HEAT PUMP BY L CARRIER OR EQUAL BY TRANE. AIR HANDLER CARRIER 7— B - - 40QB060'2000 CFM 208/1/60 WITH 7.5 KW 208/3/60 j EXAM T �2��� AUXILIARY HEATER. OUTDOOR UNIT 38BQ006, 208/3/60, f� OFFICE i p.,.1 104 1 WITH CRANKCASE HEATER AND ANTI SHORT CYCLE. COIL 103 105 CF MAX. d II 105 SECTION SHALL BE MINIMUM OF 3-ROWS WITH MAXIMUM IDX� IN OFFI7 8 2 SCD 8 SC /�� ZE�� �� 8i1$ G FLEX DUCT :.FACE VELOCITY OF 500 FPM. UNIT SHALL BE COMPLETE ANEMOSTAT MODEL D / ", � EXAM 1O0 (TYP) WITH T-STAT, SUB -BASE WITH FAN -ON -AUTO • HEAT-OFF- XSHD GRILLE ��� �F 14 Cf �/ #z-� � \ 101 t-� COOL -AUTO. SYSTEMS SHALL BE PROVIDED � WITH' ALL \ \ 8/ 24SCD NECESSARY OPERATING AND SAFETY CONTROL DEVICES AND F TT / / �I X, FAN \ // / \ 150 CFH FUSED SAFETY DISCONNECTS. LOCATE OUTDOOR UNIT ON CLOSET \� CONCRETE PAD ON, GRADE. SEE SITE PLAN. PROVIDE REFR GERANT PIPING SIZED IN ACCORDANCE WITH MANU- �v/ 102 FACTURER' S RECOMMENDATIONS. PROVIDE 1" CONDENSATE DRAIN PIPE WITH TRAP TO FLOOR DRAIN FROM HVAC UNIT. PROVIDE AUXILIARY DRAIN PAN WITH 1" DRAIN PIPE TO DRAIN SEE PLUMBING DRAWINGS FOR DRAIN LOCATION. TOILET EXHAUST FAN SHALL BE EQUAL TO PENN ZEPHYR MODEL Z6, 90 CFM @ .25 IN. S.P., MAXIMUM NOISE LEVEL OF 3.0 SONES. EXHAUST FAN SHALL BE SWITCHED FROM LIGHT SWITCH AND DUCTED AS SHOWN ON THE DRAW- INGS. PROVIDE ROOF CAP EQUAL TO PENN MODEL SL20. j PROVIDE PRIMED ROOF CAP AND PAINT TO ARCHITECT'S l SPECIFICATIONS. i s i FLOOR PLAN SUITE 106 PLAN MECHANICAL, 1 .0 ► 5, 1 4 i V 0 s I , � W J NORTH Q :f KEY PLAN: FIRST FLOOR j. i I 70 ,j cz z cz 0 p Lin CTJ r. Vrr�,, 0 Ln -C cz LD 41S 44 C tLS C) O Q w cC f... - U � (U 0 2 'E 0 V) O ll. p 4— cc V v! m Q � o LL z L H � W w U Y Z > a� Q W N 2 co0 O Z c O cc W CC Q Z 0 � � J W W -� J r J W) > N W N Z w Q 0 I 0 z O W Lr 0 I I I FILE DATE7- I a 3'_3 I a i I k I I S i i I s, I I w W �- CIO, C, o, T3 COIF) t�1EGT 1J E\\l WASTE L-1 f`lE � 70 EX 15T1 NG NMASTE MAI tJ A5 i S1v � G, To P-- 3 51 N K . , , A =L I I 1 -.1 1 11 - - - - -1 I I X� I EXAM I T Zo P 3�`cx��� 0 I w iZrI I 108 --� I it �2I r T /n11 %21 2'� / ` P I%2 1 OFFICE BUSINESS 106 �' �Y � � OFFICE • III /2 I I L P-I CC RR 211 �1 II ..411 P-2 -P-4 -- -- ------ — k L—J V CORR 41 2' siNK �' EXI STI ,l i 4" RWL 115 FRot•Ci %4" `\/A�TCORR IP 5 P-lam P 8LA 3 811 110-AA, I ---- /' 'IV 1* g" I -ILJ it .� , „CIS r /2411 411 EXISM,16 4' I/4 I% �2 2 I I VENT- STL CK 41, I OFFICE I g" XA 04 coN�11�cT Tv EX �sT 105 4 I%21 2 P-21 211 II�IG-I C,\\/, V,4L�/EI� WAITING CAP Fr--,p A-�11 100 211 w 2 P-1 \ 101 X ■ ■ , 4 �� P 5 w _ 102 2 I I PLUMBING LEGEND SYMBOL DESCRIPTION COLD WATER - HOT WATER - • COLD WATER (BELOW FLOOR) •• HOT WATER (BELOW FLOOR) —W— WASTE LINE ABOVE FLOOR --W-- WASTE LINE BELOW FLOOR ---V ---- VENT LINE ABOVE OR BELOW FLOOR C.O. CLEAN OUT ABOVE FLOOR `—" C.O, CLEAN OUT UP FROM BELOW FLOOR PIPE TURNED UP PIPE TURNED DOWN pTq i GATE VALVE SHOWN THUS - lb WATER OR WASTE RISER (DENT. " to 4 CHECK VALVE P-t, ECT. FIXTURE IDENTIFICATION -SEE SPECS C.W, COLD WATER' H.W. HOT WATER Y.T.R., VENT THRU ROOF r (TYP.) FLOOR LEVEL ON RISER -s`--r'---P' EXISTING COLD WATER LINE -0--vi-W-wk-Pbo EXISTING WASTE LINE —RWL® RAIN WATER LEADER ®® SW— - STORM WATER LINE OF" or" SW +ldOP110 EXISTING STORM WATER ...... 0-. - EXISTING GAS LINE G GAS LINE U o CL e (V I 'j • I I� ��rtt ♦v I cz 0 0 roar 0 � cTJ I U FIXTURE CONNECTION SCHEDULES (DENT. FIXTURE W. H.W. P- I WATER cEa-E-ET FwG" TA K FLooR MTb. P-2 LWATo;Z• e WALL U 6') 1/2!1 1/ Pw SI►J 65. D O -I W NEcK P-4 . SINK LA13 S5, W LAB PAUG 2 ' 2" PL5 WATB4Z EAT�1Z ELEG, 30GA1-, 1,5K\V I" [' X P-/'o Hu6p?,AI� 5n18UQ 2"AT5, w m-EP 5EALTRA X X 2" P- 7 �VATER COOLee ' 2 >C R-a F-i�" E7n u►s eR CA51 ET ASc, X X >C P- 9 Fi-00R SA.S�ki 24"x 56..x Co" ' 2" ' 2 , L N C l U V '- o '.- j U 4) o O li._ p N � V � To P-I P- 2 yE'JT T-o 4" VF NY F�►5ER CAF-1�F i� ' FLOOR PLAN SUITE 106 PLUMBING PLAN 0 5�. I � Q cc u. Z o J N J w > s Z > a� Q w z m 'z m O w Z m 9 W W J J z I >10 N W cv Z I i Q II W w J 1 1 F - JG%�j KEY PLAN: FIRST FLooR I FIB I Q V J LAMPS SYMBOL DESCRIPTION L TYPE MANUFACTURER & CATALOG NO. REMARKS NO. TYPE ® oU� TL T Fob' r'EGO LI/aH71hJG 1✓IXTUz} a OUTLET BIZ bf2Ac-K-PT L-lc* H 71 f\I t::7-I-.TUIRI✓ m A "b I Imo( K412 # T-' 244 -++0 4 F40 GW . a J L. 1 X:IAX" L16HT,A1zKoL4,6 INDICA.715- QIR4=_c-Tl®N` a B F;qo GW �z G i��D • 0 o J�INGT'I®N,�7yC,4�l��D A� F2�G21..1112Ep � a S C N-�&FzI�vToh4e :W-781-C-ncc> 2 I ©ow WALL 5?.4b1Glza�T / A I OLbl`LS7 ---"'.� GIN © P•f?x.-�! � GEyI L I NGi' off. I N I�.LL D ► IzK�"�`oNE ICJ 5c�, 51 - ra I G W (5,L0o 2 0r L-JGfH T ,----'-.. cc;1 C)u l GC7NG AI. DIN . � Lc .) 1✓Lvo lz' A) 61J .----c--.. GvN TP?Z:> , W 121 H &/ ,&os Rom` lb FUe2 4. z 3 �"�► HoMr=�UN To PArI Ll o�fzb F D'f N��A`r' L1 -ALL _. wLJNJT -rDp HTD, E-I—(f--� e-c;NDUI T TeLe fmHc W r- I'' U, �� r F-I h�i' U�EE� pollTELr I oNe c JTL. "(, 14'' A,�f, �inl=I�.Ia.LL,K p,,s411 a,�F,, L;fU F'LE✓v, '�2_r,Caf=74,GLe , 1¢11,6,, . TG I s IW' UrDF:-rz. t;; - LV�-_-42 X FZeeepT-'GLr,-, MTD_ AE3G ofeP 412 A, FF-, e-xk+&u�-T �p,N O THfzMc�57AT ELECTRICAL NOTES A - LI�H'TING-r F'aN�l-ESvl�,I"2CC� WORK UNDER THIS DIVISION INCLUDES THE FOLLOWING: I I EXAM EXAM �� �IJ�I�L-F=`�ETYI^l,,.gl(�© - - - -I - - - 107 I 108 1 A.5-1pz. FINI�H�fJLG~�� LIGHTING FIXTURES AND POWER RECEPTACLES. POWER, INTERLOCK AND v CONTROL WIRING FOR MECHANICAL SYSTEMS. 1 __- L L-1NLIE-4.,47 OTHFe2 llI_11;� Nczvl�CD o / 1 50 o A51l Go a U NT't=9Z RACEWAYS AND WIRING FOR OWNER -FURNISHED EQUIPMENT AND EQUIPMENT a FURNISHED UNDER OTHER DIVISIONS. EMPTY RACEWAYS FOR TELEPHONE SYSTEM (AND DICTATION SYSTEM, IF PROVIDED) . OFFICE 1 ,` BUSINESS < CE COMPLETE DISTRIBUTION SYSTEM FOR LIGHTING AND POWER INCLUDING 1O9 NECESSARY FEEDERS, PANELBOARDS, BRANCH CIRCUITS AND CONTROL y i i SWITCHES. _ �. GROUNDING. T E 3 WORK SHALL BE INSTALLED IN ACCORDANCE WITH EDITION OF NATIONAL ELEC- , CORR TRICAL CODE IN EFFECT IN AREA, WITH STATE AND LOCAL ELECTRICAL AND BUILDING CODES, AND WITH SPECIAL CODES HAVING JURISDICTION OVER B� B SPECIFIC PORTIONS WITHIN THE COMPLETE INSTALLATION. Cl {ZE=Ci�j`�AGLE EE ELECTRICAL SERVICE SHALL BE 120/208 VOLTS, 3 PHASE, 4 WIRE UNLESS D - i T I-,►_ - �r2 OTHERWISE INDICATED. I `__j E CORK WIRE AND CABLE: B B dR BRANCH CIRCUIT WIRING NO. 10 AND SMALLER SHALL BE COPPER, o_9 PA'I�IEL o-E,5 1 1O E SOLID, TYPE THW OR THHN/THWN. NO CONDUCTOR SHALL BE SMALLER 1 THAN N0. 12. FEEDER AND POWER WIRING N0. 8 AND LARGER SHALL BE COPPER, CLO ET 1---� STRANDED, TYPE THW OR XHHW . I r_ - E i D -q ' CONTROL WIRING SHALL BE NO. 14, TYPE THHN/THWN. DI i LIGHTING, POWER AND CONTROL WIRING SHALL BE INSTALLED IN CONDUIT - - - INDICATED. PVC SCHEDULE 40 OR RIGID GALVANIZED CONDUIT SHALL BE EXAM _ USED WHERE RUN UNDERGROUND OR WHERE -CAST IN GROUND FLOOR CONCRETE. OFFIC 104W 3 TURN UP ALL PVC CONDUITS WITH RIGID GALVANIZED ELBOWS. USE RIGID 1O5 / GALVANIZED WHERE EXPOSED TO POTENTIAL MECHANICAL DAMAGE OR WHERE RUN _ _ _/� WAI OUTDOORS EXPOSED TO WEATHER. ELECTRICAL METALLIC TUBING SHALL BE / \ AM 100 USED'WHERE CONCEALED IN WALLS, WHERE RUN EXPOSED IN EQUIPMENT ROOMS i ! \ 1 1 AND WHERE INSTALLED ABOVE CEILINGS. PANELBOARDS SHALL BE DEAD -FRONT TYPE EQUIPPED WITH THERMAL -MAGNETIC / SE 1 MOLDED CASE CIRCUIT BREAKERS. i \ _ — - 1 I v SAFETY SWITCHES AND DISCONNECTS SHALL BE GENERAL DUTY, HORSEPOWER _ _ _ RATED. PROVIDE REJECTION FUSE CLIPS AND UL CLASS "RK5" TIME DELAY DUAL ELEMENT FUSES IN ALL FUSED DISCONNECTS SERVING MOTORS. TELEPHONE SYSTEM (AND DICTATION SYSTEM, IF PROVIDED) SHALL CONSIST F-1 OF OUTLET BOXES, EMPTY CONDUITS AND RACEWAYS,.AS SHOWN ON DRAWINGS. 11 DEVICE PLATES SHALL BE IVORY SMOOTH UREA EXCEPT ON DARK COLORED PANELED WALLS; USE BROWN PHENOLIC ON THESE. OUTLET BOXES SHALL BE GALVANIZED STEEL. PROVIDE EMERGENCY LIGHTING WHERE REQUIRED BY NFPA 101, 26-2.9.1 AND AUTHORITY HAVING JURISDICTION. PROVIDE FIRE ALA_RM__aY_STEM-AS_RE_ UIRED BY NFPA 101, 26-3 .4 , NFPA 101, 7-6, AND SHETHORITY HAVING JURISDI lQ0N.. L FLOOR PLAN SUITE 106 ELECTRICAL LIGHTING PLAN k 1, 6LL FI XTURE.A.=, TYI-s nAu Ut,1 LESS oTHl~R-W 16E Nr�'ED, KEY PLAN: FIRST FLOOR BRUNING 44-142 57188 i �Q i F/ w P - 36 A �UL GoresD, UNIT FLOOR PLAN SUITE 106 ELECTRICAL POWER PLAN 0 BRANCH CIRCUIT BREAKERS CIR. NO. AMPSJ POLES MIN' S.I.C. 1,3,5,? 20 I lovoo 2 ID 12,14 IS 17 403 IS 40 3 23,25 20 24 2l0 11, 1 3, 27-30 20/6P EXISTING INCOMING 400 AMP SERVICE • ENT ELEVATION 1 ELECTRICAL ROOM NO SCALE 1, I'll G, H. 40 Pvc, Tc;, MAI ► l TE L . ac), 1t4 TELEhHc>Na pocp". 2. TYF'. TeLEPHoNF- oUTL15j w/ 1116 STU613ED W/ GoN N FGT'P� 5L;,(oH I f NORTH KEY ;PLAN: FIRST FLOOR I ui ILL 'Q 0 m co W .� v a o cc a '> i CAS z o C�$ co • O Ljol (d U co rZ � cC3 O ca co05 _E Cd ° O LL p .� . j. 0 C '? O � Z � d m LL z w U� w > � U 2 Z>� Q w N z (n o o . O 0 w Q w 0 z W W J J z J ,o N W N Z cr a z O W L B O. I FILE y DATE ���3aL[ f�l��