HomeMy WebLinkAboutRevco Drug Store (a)w:� �--12' CONC. BLOCK
cn TIGHT TO ROOF DECK
cr
ar n.
w 5/8" FIRE RATED GYP. BO.
cr w
`n FL. TO CL'G. PAINTED.
a� X .Q
w
v caa� v -
O Y CC
cp
cc
w M W
Z lL d '
H O L1..
L.L
ftti•. ,I
lL LL hC7.. 1...
., -cc !
sr Q LL =
a
r'` s Cu
O
iB o _� t o
LJ J ,
a a 7 aco
CD X
18 tU. h
� q .
a a
-
'v B'-0"
NOTE: 43'-0"
a CURTIAN WALL DOES NOT
CD
..7 TURN w/RAISED FLOOR.
3 r
THIS IS TO BE LOCATION
E \ 0 0, 3 OF COLUMNS IF REQUIRED
co NO DEVIATION FROM THESE
5' -- I 1 " SALES AREA MEASUREMENTS.
w FROST PROOF HOSE \ , CL ' G . HT. 11 ' -O " A.F.F.
cn I
_ BIBB W/CONTROL ON
n IRiERIOR OF STORE
� O w � f
i 3f? O.r
Q I 3' -5'
to o.
_rn ` I F.E. 0UTIAN WALL . ,y :,c•
2 RAINT RX & LOCKER 2
COATS; WHITE LATEX
ILSEMI=GLOSS ENAMEL
o QCUG HT * AB.
\
SALES AREA FLOOR !�o
El
O G
RX DEPT •
12 " RAISED FL.
o ooti cql
®� \ y yFc� F
4' q
1 s1,y� 5/8" FIRE RATED GYP. BD.
�.1 FL. TO CL'G. PAINTED.
SECURITY LOCKER 2'X4" STUD WALL TO WINDOW SILL r
HT. W/5/8' FIRE 'RATED GYP. FTIGHT
i2 CONC. BLOCK
VFJ-i n� m„-r„ „Tm"n TO ROOF DECK
-CANOPY
o
!
co
is
CD
5"
13'-0"
f
t
{
.
•
a
-
STORAGE ROOM
2*4 STUD'WALL FLOOR TO TIGHT TO
HOLD CL'G. A5 CLOSE TO ROOF
ROOF DECK ww/5/8° FIRE RATED GYP.
FRAMING AS POSSIBLE
BD. BOTH'SIDES PAINTED.
f
y ,
Y r
yt Y
i
43 -0
UNIT HEATER
3
C -• SUSPENDED
FROM CL'G.
'
RED TILE FOR
.,
FIRE LANE
BLACK VINYL
A EDGE STRIP
LESSOR TO FURNIS'i & INSTALL 12 GAL. ELECT.
3
c;
H.W.H. MTD. ON SHELF 7'-O' A.F.F.
F.E.
F.E. 0
6
v
m
8 }
cn
a
O
cc
`--/
n
J
Z
a
/
coco
U
�
'LESSOR TO FURNISH & INSTALL 20"X28"
w
CAST IRON ENAMELED SERVICE SINK
_
'�°
1
3
ca
;i
WALL MTD,� w/RIM GUARD, H&C WATER,
o
EO
Jzu
DRAIN, VENT, ETC.
.'
as
N
8
1
,
io
m
J
3
4
6 6
LESS* TO FURNISH & INSTALL 1/20
Sol
5 "
COLD WTR. DRAIN VENT ETC. & HALSEY
o
a 5
Q
TAYLOR 'WTR. COOLER #S3C1
TRASH
ROOM,
a
9
'REVCO', 'DISCOUNT', 'PRESCRIPTIONS', ETC. RED LETTERS
WHITE BACKGROUND
BLUE BORDER—, I
R.FjV\ 1�I PRESCRIPTIONS
� urwl'ru nmc
CL'G. HT. B'-Om A.F.F. aQ/
IECEIVED LEASE EXHIBIT :C{.
DESIGNED STRUCTURES, INC.
P. 0. Box 426
Lake Mary, FL 32746
REVCO REQUIREMENT DRAWINGS
rJUN f 0 1983 DO NOT USE FOR CONSTRUCTION
L.H.
lw
DISCOUNT
BEAUTY AIDS
SCALE: 1/4' � 1'-0' DRAWN BY:
RUGS
"�" I i�i
VITAMINS Sk
vc
DATE REVISED:
DISCOUNT _
CONSTRUCTION PLAN
Df1GS BLUE.LETTERS
WHITE BACKGROUND
DRUG CENTERS
DRAWING NIEA
RECESSED SIGN .
(4'-0' X 9'11
i OF 3
CL
O
Z
a CL
W LU
Z C121
w w
CC x _Ile
O H a
LL. I— LLJ
C) L m
7-1cn
0 Q O
_�cv
-7:) Cn r+
J
(21
ca _
C3
w H
Ljj
w z
CC
cc U) w
Y
O O W
>G
o H 0-
m U) Q
o = N
Zu cc
W Cv
D o
J
_
w
Y
a
w
_
m
m
M
a
C]
cu
I—
C
w
J
Cl
M
U-
C)
C)
cc
CL
w
t--
a
w
3
2'-0" A.F.F.
I
•
N
•
6'-0" l0'-0" i0'-0"
10'-0"
10'-0"
i0'-0"
10'-0"
i0'-0"
i0'-0"
i0'-0"
10'-0"
Cn
4'-0" CWc
5' -0H (7
I
'
CD
U- H O
W > u
I— J
D
H W W
_' = °c
cn
•
Cc � m
_ C)
J W W
J U- m En
F--
a W Y En
m U H
O W
>_
1
a
En a / F- cm Z
Lo
Cc
-
0°
42' -0"
Cn (9 J
o U-
Lu
W
" Lu En
U- J \
0 •cx CD Fa- W
C] rn to �--
•
a O CV H a
En
=) O
En
D
co
p
2'-0' A.F.F. OUTLET RUN CONDUIT FROM MALL
w
w/LOCKOUT @ E.P. i8 FROM FL. & 12
EQ . EQ .
FROM EDGE OF WALL.
iz
=o EL
C.R. OUTLETS REF.
m
cc
w
w
DETAIL SH. 03A OF 3
0
W
O
li CQ1 L _
Imo . Phi M OUTLET p
Q C Q
'2 1-36 FLUOR LT •
_ r
�r FIXT. BOTTOM ROM
o1 o is
F--
a
W
WC,'
J
CC
U u-
s
PLASTIC SIGN FACE W
a
LD i ►-
w
2'-O' A.F.F. OUTL
w/LOCKOUT @ E.P.
co
p
DUPLEX OUTLETS MTO. IN OR ON
COUNTER BY LESSOR AFTER EQUIP.
IS SET BY REVCO. 00 NOT RUN
-� �
. . / E IN SAME CONDUIT wC.ROUTLETS
•
a:�
W
(, lL �
gyp,.
W LL' 60 W 4
W `` �►
OUTLET 14-48' FLUOR. LITE FIXTS.
w cu
2 ROWS REF. DET. if-3 OF 3
o
EQ EQ ,1% F
1
1
I
c
`O
co
p CWiAIN MALL
EQ. @ EQ.
DUPLEX OUTLETS MTD.
•
IN OR ON COUNTER
AFTER EQUIP. IS SET.
H.M.N. OUTLET VERIFY
M. w/)FG.
'o
60 W 108
D
D
D
D
D
D
D
2'-0' A.F.F. 20 AMP
3-36' FLUOR LT.
BREAKER
A
FIXT. BOTTOM ROM
TO L.P. C
C
C
C
C
C
C
C
ON TRASH "100 M.
O N.M.H. OUTLET VERIFY o<A
f-36' FLUOR LT. FIXT.
`�
{
Rm. C''6.
J CNAR. r11Fs.
TOP ROM NOT SHw
cv
NOTE:
1. ALL SURFACE MOUNTED FLUOR. LITE FIXTS.
TO BE MOUNTED FROM 1-1/2" SPACERS TO ALLOW
AIR CIRCULATION TO PREVENT BALLASTS
FROM BURNING.
2. ALL ELECTRICAL EQUIPMENT IS TO BE
FURNISHED & INSTALLED BY LESSOR.
0
0
1
cn
C1J
DOOR
SCHEDULE
DOOR, HARDWARE
DOOR
NUMBER
FRAME
I OPENING
ITHICKNESS1
MATERIAL
I THRESHOLD.
ILABEL
I FINISH
I
I REMARKS
No.
DESCRIPTION
ol
6
It000 �ti�� ���cY
�C, c
,0
P
To�o� tipti��,� QQ'
Q `T
I
"KAWNEER" #204 CLOSER, STYLE "L' PUSH BAR, BUTT HINGES WITH LOCKPINS, FLUS4 MAXIMUM
SECURITY CYLINDER LOCK. DOOR 1A TO HAVE PUSH BAR ON INTERIOR ONLY (NO EXTERIOR
HARDWARE)• DOOR iB TO HAVE PUSH BAR AND/OR PULL BAR BOTH SIDES.
II
DOOR CLOSER, LOCKSET: "SCHLAGE" A51PD-TUL iO-KA 2
III
DOOR CLOSER, KICKPLATE (S) , PASSAGE LATCH: ",$CHLAGE" A10 S-TUL10
IV
DOOR CLOSER,"SCHLAGE" LOCK #B252PD, LOCK FROM STOCK ROOM ONLY.PINS REM'ED FRAM RUBBISH
ROOM SIDE . DOOR PULL, STOCK ROOM SIDE .STANLEY #482J4, 7 7/8" L.1 pp. LAWRENCE HDWR . SO.
SPRING BOLTS 6' L 1" SO.#SC286ZN 18' FROM TOP AND 18" FROM BOTTOM.
!A s ie
2
3
4
5
•
•
•
•
®
•
0
®
®
•
•
•
•
•
•
•
•
•
•
0
1
1
•
®
O
®
•
O
O
•
•
O
•
0
0
O
•
I
II
III
IV
v
KANNEER OR APPROVED EQUAL
V
180 DOOR CLOSER & HINGES, "SCHLAGE" LOCK #B252P0, LOCK FROM RUBBISH ROOM SIDE ONLY, PINS
REMOVED FROM OUTSIDE DOOR PULL STANLEY #482J4 7 7/8" L. (RUBBISH ROOM ONLY) (1) PAIR
LAWRENCE HDWR. S . SPRING BOLTS 6" L. 1" SO. #SC286ZN 18" FROM TOP AND 18' FROM BOTTOM,
LOCK PINS ON BUTTS.
7
B
•
®
•
®
•
A
•
•
O
•
•
•
•
•
O
O
0
•
•
•
O
vI
VII
VIII
'KAWNEER OR APPROVED EQUAL
VI
180 DOOR CLOSER '& HINGES, PANIC HARDWARE ALARM LOCK 70R PUSH BAR BATTERY OPERATED LATCH
TYPE, PINS REMOVED FROM OUTSIDE. BUTTS TO HAVE LOCK PINS. 1 PR. LAWERENCE HDWR. S .
SPRING BOLTS 6' L. i" SO. #SC286ZN, 18' FROM TOP AND 18" FROM BOTTOM.
V I I
STYLE "L" PUSH BAR ON VESTIBULE SIDE ONLY! NO HARDWARE ON INTERIOR. FLUSH MAXIMUM
SECURITY CYLINDER LOCK. OVERHEAD DOUBLE ACTING CLOSER. 180 PIVOT HINGE IN THRESHOLD
USE PLASTIC BREAKAWAY STOP ON ALUM. JAMB. (DOOR TO SWING IN ONLY).
VIII
DOOR CLOSER, KICKPLATE(S), PRIVACY LOCK.
4T
b
ROOM FINISH' SCHEDULEc#
Ct REF. DET. CL
HEATHER STRIPPI
ROOM # FLOOR BASE WALL (S) WALL FINISHES CEILING L'G. FIN. CL'G. HT,
_ . HIDE
DGE1 LOCK LOCKPINS DOOR PU I
SCN A6E LOCK 'MITT g' LOCK
1B32PO ON BUTTS
LAifm HRObff. LAilm 11m.
tsc290 WV.) #Sc2 o tM.)
OUTSIDE YESTIBULE I O O 1 10 *1 1 1 • 10 1 1 1• • • TRASH Rai. STOCK PA. EXTERIOR INTERIOR
INSIDE:YESTIBULE 2 0 1 0 0• 0 1 0 01 10 1 SIDE SIDE
SALES AREA 30 1 0 O 0 O O O 01 1 10 ® 1 10
RX DEPT 4 0 0 O 0 O 0 0 0 1 1 10 0 10
RX SECURITY LOCKER , 5 0 0 • O 0 0 1 is 0 0 DOOR 04 DOOR #5
STORAGE ROOM 6 01 1 01 1 010 0 • 0 0 •
MEN'S TOILET 7 0 ® 0 0 0 O 0
WOMEN'S TOILET 8 0 • 1 0 O 01 •
TRASH ROOK 8 0 O 0 0 O 1 • 0 109
DRIP CAP
REF. DET. CL
*ATO smPP
135'
HITIF,I Kul
01
LOCKPINS A 'ALARM LOB(' 7OR
� iBNSTLMAIN SERVICE PANEL DN �TTSELECTRICAL SYMBOLS oo
OPEMI6)
LAIi}lCE tfplRE.
HIMSE fSC2B61?i tTiP.) SIM LENIEL
�• = FLUSH FLOOR OUTLET
} = EXTERIOR INTERIOR
TELEPHONE OUTLET
= ISOLATED/INSULATED
INCANOESCENT�FIXTURE w/ GLASS DRUM
• _INCANDESCENT FIXTURE w/PULL CORD ``',-GROM: BUSS
DOOR 06 DRIP CAP DETAIL
.C. o o o o o O
N NO SCALE
DUPLEX.CONVENIENCE OUTLET
GOQSE'NECK FIXTURE w/ WIRE GUARD WEATHERPROOF
.. FEEDER MIRE FROM SERVICE PANEL TO G L I D D E N EQUIVALENT
-= JUNCTION BOX DISTRIBUTION PANEL TO BE RM IN CHIT.
P & L (COLORS MATCHED IN
H.W.H. OUTLET VERIFY 'CHARACTERISTICS 'w/ MFG. _ COLOR & NUMBER SPRED SATIN)
ISOLATED/INSULATED CIRCUIT BREAKERS
=WIRE GUARDED INCANDESCENT LT. FIXTURE GRO(M BUSS VALUE DETERMINED BY TYPE B 698 M VIVID BLUE 77 - 34
Q❑ = ELECTRICAL BELL o 0 0 0 0 o AM NUMBER OF DEVICES IN BRANCH. t Y 0274 W IVORY MIST 70 - 25
IS(X..ATED 6ROl) RECEPTACLES 0221Y ORANGE BERRY 72 - 47
❑ = PUSH BUTTON VHUBBLE (210 AMP.) 1536i ORANGE YG510Y ENVY' S EYES 3496 OT. FORMULA
`= EXHAUST FAN ° 18 LY
2P40YGR
I -----I = SINGLE TUBE FLUOR-. LT. FIXT. (TUBE LENGTH AS NOTED) 2 NT
A DETERMINED BY DER 0236Y MAIZE GOLD 3495 OT. FORMULA
= 48' . SURFACE MOUNTED 4 LAMPS FLUORESCENT LT. FIXT. OF CASH REGISTERS 48 RD
IP46 LY
96" SURFACE MOUNTED 4 LAMPS FLUORESCENT LT. FIXT. C i PW
= 48' SURFACE MOUNTED 2 LAMPS FLUORESCENT LT. FIXT. 0216Y MIDNIGHT SUN 3495 QT. FORMULA
n 96" SURFACE MOUNTED 2 LAMPS FLUORESCENT LT. FIXT. IP32LY
O
IP32RD
EMERGENCY LIGHTING BATTERY UNITS i FR
Y321 Y BURNISHED GOLD 3495 OT. FORMULA
NOTE: ALL FLOUR: LT. FIXTS. TO BE MOUNTED FROM 1 1/2" SPACERS, EQUIPPED w/ o IP32 YOX
ENER"G'SAVER BALLASTS & "G.E. SLIMLINE ENER"G"SAVER" REDUDCED WATTAGE
1P 32 W
F96 T 2 CW/WM. 16 RD
= THERMOSTAT ° 50 LY
,�, Y0306A SUNLIGHT MESA 3495 QT. FORMULA
= EXIT LIGHT (RED) iPYOX 1PLY
DISTRIBUTION PANEL
�R = INCANDESCENT ,RECESSED WATERPROOF LIGHT 48 RO
32NT 32W
Q = SINGLE HEAD WALL MOUNTED BATTERY PACK EMERGENCY LIGHTING CASH REGISTER OUTLET WIRING DIAGRAM
i. ALL ROOF OPENINGS LARGER THAN 12'Xi2" TO HAVE STEEL BAR GRATING(S).
2. 'MARLITEm PLANKING INDICATED ON PLANS & ELEVATIONS TO BE 1/4" 16"
WIDE TONGUED & GROOVED EDGES, "NATURAL OAK, 4' SCORE, #326—S4
3. PAINT ALL COLUMNS (IF ANY) WHITE ENAMEL 4'-6' A.F.F. TO CEILING
& BEIGE FLOOR TO C —6" A.F.F.
4. NO INTERIOR COLUMNS IN STORES OF 60'-0" WIDTH OR LESS,. NO PILASTERS
ON ANY WALLS IN STORES OF ANY WIDTH.
5. PARTY WALLS TO BE 12" MASONRY SEALED TIGHT TO ROOF DECK.
6. MINIMUM OF 6' INSULATION w/R19 RATING ABOVE CEILING.
7. INTERIOR SIDE OF,QUTSIDE MASONRY WALL TO HAVE iX3 FURRING w/i"
STYROFOAM INSULATION OVER FURRING & 1/2" FIRE RATED GYP. BO. OVER
STYROFOAM INSULATION, PAINTED.
B. TREAT CONCRETE FLOOR IN RUBBISH ROOM w/MATERIALS FROM ONE OF THE
FOLLOWING MANUFACTURERS:
a) "BROWN CO., INC." CEMENT SEAL COAT (CLEAR)
b) "PORTER PAINT CO." #3200 CLEAR ACRYLIC FLOOR SEALER
9. TERRAllO FLOOR FORMULA: 60% GEO WHITE
30% OXBLOOD RED
10% OLD YELLOW
w/WHITE CEMENT & POLYMER
(CONTACT 'REVCO" FOR SAMPLE)
ALL TERRAllO FLOORS TO BE STRIPPED & SEALED.
TERRAllO FLOORS (8'-0" SQUARES) TO HAVE BRASS DIVIDER STRIPS.
10. ALL TILE FLOOTS TO BE CLEANED & WAXED.
11. ALL EXPOSED DRYWALL AREAS TO RECEIVE 4" DARK BROWN VINYL TOPSET BASE.
12. ALL WHITE PAINT TO BE MOORE'S DULAMEL SEMI —GLOSS (SEE PLAN)
i3. BROOM CLEAN PREMISES OF ALL EXCESS DEBRIS.
14. H.V.A.C. UNIT(S) TO BE "CARRIER" OR "SINGER",•"REVCO" TO APPROVE DESIGN.
15. UNIT HEATER SPECS.: 20,000 B.T.U. — ELECT. / 25,000 B.T.U. — GAS
16. ALL H.V.A.C. UNITS TO HAVE MINIMUM WARRANTY OF 5 YEARS.
0. ALL FLUORESCENT TUBES (EXCEPT IN CURTIAN WALL) TO BE G.E. SLIMLINE
ENER—G—SAVER , REDUCED WATTAGE F96T12/CW/WM
18. BALLASTS TO BE F96 'SLIMLINE G.E. MAXI -MISER II HIGH PERFORMANCE
BALLASTS" OR EQUIVALENT.
19. DRYWALL CEILING AREA OF OUTSIDE VESTIBULE TO BE CONSTRUCTED w/SECURITY
PROTECTION. i'X1"X1/8" DIA STEEL GRATING ON 2X4FRAMING 12" O.C.,
WHERE APPLICABLE.
20. TOILET ROOM WALLS TO BE COVERED FLOOR TO CEILING w/WHITE MARLITE
824 GOLD FLAKE.
21. WATER CLOSETS TO BE AMERICAN STANDARD BOWL 2222.016 , SEAT BLK. #10
FLUSH VALVE SLOAN #110 , OR APPROVED EQUAL.
22. LESSOR TO FURNISH THE FOLLOWING TOILET ROOM ACCESSORIES:
a. SANITARY NAPKIN DISPENSER & RECEPTICAL IN WOMENS ROOM
KIMBERLY CLARK CORPORATION #K70740 OR APPROVED EQUAL (w/FREE MECHANISM)
b. SOAP DISH
c. MIRROR ABOVE EACH LAV.
d. METAL TRASH CAN
e. SIGN READING 'MEN AND/OR WOMEN" ON -DOOR
f. TOILET PAPER HOLDERS
g. GRAB BARS FOR HANDICAPPED
23. HARD PAVE REAR OF 'REVCO* STORE. FROM REAR WALL TO A MINIMUM DISTANCE
OF 50' BY THE WIDTH -OF STORE w/A MINIMUM 10' WIDE ACCESS ROAD.
24. LESSOR TO FURNISH FIRE EXTINGUISHERS AS INDICATED ON PLAN.
FE = 5 LB. ABC DRY CHEMICAL FIRE EXTINGUISHER
FE = 10 LB. ABC DRY CHEMICAL FIRE EXTINGUISHER
i0
25. WEATHER STRIPPING AT ALL EXTERIOR DOORS.
26. VESTIBULE FLOOR TO BE "SAF-T-TRED' GROOVED RUNNER CEMENTED DOWN
#1000-G MARBLEIZED MAHOGANY COLOR 'R.C. MUSSON RUBBER CO."
3A OF 3
0
41