Loading...
HomeMy WebLinkAbout312 W 1 St 99-2947 Interior Remodel Federal Trust bankt tJ :'1trl ft a l—tf sf,.Iff aVv. Lf -4'1-L V f--0 lu y 14, 1999 City of Sanford BuIldinq Department P.O. Box 1788 Sanford, Florida 32772.-1788 aanteGroup Inc. Via Fax 407.330,S677 Architecture and Construction Attn: rvir. Biil culbeit'son, pkim Examiner l;e: Fedpra) Trust Bank 604 N SelcherRc,ir1. .I Jae 100 312 West First Street Ctp,rwater, flo ri.t J37G;-Z103 Sanford, Honda voice 727.443.1061 Dear Mr. Culbertson. fvc 727.432.0609 v v,,y q„ir,.Urauia corn This letter is to cunrion our telephone conversation of July 19, 1999 regarding the above project. The *Vllovving leans vv'ere disczisiwd: 1. dole No. 2 or? Drawing No. A-! %Ayiii'l,,,:rlpvned to delete the phrase'"see i iUmbing drawings for additional infort71.9tiorf' 2. Tempered glass will be used only at the new Storefront doors, it will not be used at the new windows. hch. lieu. M W07237 FL ConVxtw Ur CC, (0106 3- Note 9 on Drawing M-t will be deleted as it is not required. Revised tJi,iYving5 will be Sent to you for i7tseilion into your record It You lic-M! further questions of conimients, picise conitaci me - Sincerely, 11 an"Group, Inc. richard Adelson. Architect President ii r CITY OF SANFORD BUILDING DIVISION COMMERCIAL REVIEW COMMENTS INTERIOR ALTERATIONS PROJECT:vtzrofz, ADDRESS: 3( Z Gv• Frzs 5-/ SANFORD, FL CONTRACTOR: Flml icf, Lo,c/ I.r/G+ LIC# i3G a S%SSW ADDRESS: (G,J 5-,Z00 PHONE: (7,7) 6774 jar 1. Means of egress and occupant load shall comply to Section 1003 1997. S.B.C. 2 Means of egress and illumination shall comply to Section 1016.1, 1016.2 and 1016.3 signs), 1997 S.B.C. 3. All corridors shall be a minimum of 44", Table 1004,1997, S.B.C. e— 4. All restrooms shall comply to 1997, H.C.F.S, 553, Part 5. 5. Interior finishes shall comply to Sec. 704, Table 803.3,1997, S.B.C. 6. All electrical wiring service & fixtures shall comply to 1996, N.E.0 and Notice L amendments. 7. All plumbing shall comply to 1994,S.P.C. 8. All mechanical equipment & duct systems shall comply to 1997, S.M.C. & 1997, Florida Energy Code. ems 9. Firewalls or tenant separations shall comply to Table 413.3 & Table 704.1 & 704.1.4, penetrations shall be sleeved and fire caulked. 10. Stairs shall comply to Section 1006,1007,1007.1.2,1007.3,1007.4,1007.5,1007.5.3,1007.6,1007.7, 1007.8,1008.6, & 1015, 1997, S.B.C. 11. Shall comply to 1994, N.F.P.A. -1. 12. Shall comply to Life Safety Code 101,1994. i Review By: e-j"k- REQUIRED INSPECTIONS DURING AND UPON COMPLETION OF CONSTRUCTION: 1. Footer 2. Underground electrical, mechanical and plumbing 3. Slab 4. Lintel and/or tie beam 5. Rough electrical 6. Rough mechanical 7. Plumbing rough 8. Tub Set 9. Framing ( 10. Insulation, walls and/or ceilings b04c e--ky('s twi 11. Electrical final, mechanical final and plum 12. Building final Date: /! Signature 3 CITY OF SANFORD BUILDING DEPARTMENT SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PERMIT 1. Two (2) complete sets of plans and drawings to scale and to include; 1A- o A/p- a. Site plan approved by Planning & Zoning and City Commission b. Boundary and building location survey C. Foundation plan d. Floor plan e' 1. Room or space identification 2. Indicate room dimensions 3. Specify door and window dimensions and types 4. Indicate tenant separation and fire resistant walls. Complete UL design noted. e. Four (4) or more elevations including finish floor(s) elevations, f Structure details -signed and sealed by engineer g. Architectural drawings signed and sealed by architecth. Electrical drawings -signed and sealed by engineer, if over 600 ampsi. Mechanical drawings -signed and sealed when 15 tons or more and/or 5,000.00 C1/' j. Plumbing drawings -signed and sealed, shall comply to Florida Handicap Code. 11 2. Plans shall show: a. Square Footage b. Type of construction c. Occupancy classification (group) d. Occupant load o,tml N e. Sprinklers, standpipes and alarm systems f. Fire protection requirements & NFPA requirements Life Ono' 3. g. safety Code 101 Three (3) sets of Florida Energy Forms 40OD-97 signed and sealed by architect or engineer. 4. Arbor permit when trees are to be removed from property. Contact the C t 5. City Engineer for details regarding the Arbor Ordinance and permit. Soil analysis may be included on site plan or foundation 131y,4_ 6• Soil analysis and/or soil compaction report. If soils appear to be unstable or. if structure to be built on rill, a report may be requested by the BuildingOfficialorhisrepresentative. olth'7. Utility Letters Required Inspections During and Upon Completion of Construction 1. Footer 2. Underground electrical, mechanical and plumbing 3. Foundation elevation survey 4. Slab 5. Lintels -tie beams -columns -cells 6. Rough electrical 7. Rough mechanical 8. Rough plumbing 9. Tub Set 10. Framing 11. Tenant separation/firewall 12. Insulation, walls and/or ceilings 13. Electrical final, mechanical final, and plumbing final 14. Building final / 15. Other DATE--y " /J — SIGNA or Authorized Agent) r-. CITY OF SANFORD FIRE DEPARTMENT 1303 South French Avenue Sanford, Florida 32771 407) 302-1091 (407) 302-1097 FAX Plans Review Sheet Date: July 13, 1999 Business Address 3j12V Business Name: Federal Trust Bank Ph. Occ. Chap. 26 Contractor: Florida Concepts Ph. (727) 447-6776 Reviewed [ ] Reviewed with comment JJ'[ X]Rejected Reviewed by: Bart Wright, Fire Protection Inspectoro 0 Dy/- Comment: 1.1 Application — Alteration to an existing business occupancy 1.2 Mixed - N/A 1.3 Special Definitions - N/A 1.4 Classification — Existing business LSC chapter 27 1.5 Classification of Hazard of Contents - Ordinary 1.6 Minimum Construction — N/R; applicant notes type II const. (SBCCI); Type 1 (332) NFPA 1.7 Occupant Load — 1/100 sq. ft. (for egress capacity) 2.2 Means of Egress Components - O.K. 2.3 Capacity of Egress - O.K. 2.4 Number of Exits - O.K. 2.5 Arrangement of Egress - O.K. 2.6 Travel Distance - O.K. 2.7 Discharge from Exits - O.K. 2.8 Illumination of Means of Egress - O.K. 2.9 Emergency Lighting — N/R 2.10 Marking of Means of Egress - O.K. for all uses; will field verify 2.11 Special Features -None noted 3.1 Protection of Vertical Openings —None noted 3.2 Protection from Hazards — N/A 3.3 Interior Finish - Class "C" 3.6 Corridors - N/A 4 Special Provisions - None noted 5 Building Services - No comment 5.1 Utilities 5.2 HVAC 5.3 Elevators, Escalators, Conveyors (4A-47) 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes Sanford City Code - Chapter 9 Fire Sprinklers: N/A to build out Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes —N/A to build out 3-6.1 Key Box — N/A to build out 3-7.1 Bldg. Address Number Posted and Legible — N/A to build out