Loading...
HomeMy WebLinkAbout2020 McCracken Rd 01-1567 and 01-1569 Fire inspection Calvary Temple of PraiseSANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 Plans Review Sheet Date: 4/16/01 Business Address: 2020 McCracken Rd. Occ. Ch. 29 Business Name: Calvary Temple of Praise Ph. (407) 324-0126 Contractor: Ph. Reviewed [ ] Reviewed with comment [ X ] Rejected [ ] Reviewed by: H. A. "Pete" Tucker, Fire Protection Inspector Comment: Plans reviewed as Storage Occupancy. FD reserves right to require applicable code requirements if occupancy use changes. Exit doors need to swing in the direction of egress. Exit Lighting and Emergency Lighting not noted on plans, will field verify. (Pavilion not subject to Life Safety Review) 1.1 Application — New Building. Type V Const., 1200 sq.ft. 1.2 Mixed — N/A 1.3 Special Definitions — N/N 1.4 Classification of Occupancy — Storage 1.5 Classification of Hazard of Contents — Ordinary 1.6 Minimum Construction — N/R 2.2 Means of Egress Components — O.K. 2.3 Capacity of Egress — O.K. 2.4 Number of Exits — O.K. 2.5 Arrangement of Egress — O.K., will field verify 2.6 Travel Distance — O.K. 2.7 Discharge from Exits — See Con-iments 2.8 Illumination of Means of Egress — See Comments 2.9 Emergency Lighting — See Comments 2.10 Marking of Means of Egress — See Comments 2.11 Special Features — N/A 1 w , '( SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 407 302-1022 / FAX (407) 330-5677 Pager (407) 918-0388 3.1 Protection of Vertical Openings — N/N 3.2 Protection from Hazards — N/N 3.3 Interior Finish — Class "C" 3.4 Detection, Alarm and Communications Systems — N/A 3.5 Extinguishing Requirements — as per NFPA 10 3.6 Corridors — N/A 4 Special Provisions 5 Building Services 5.1 Utilities — N/A 5.2 HVAC — N/A 5.3 Elevators, Escalators, Conveyors (4A-47) — N/A 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes — N/A Sanford City Code — Chapter 9 Fire Sprinklers: N/A Monitoring: N/A Other: NFPA 1 3-5.1 Fire Lanes — Required if building is more than 150' from street; exception: building has fire sprinkler system. 3-6.1 Key Box — N/A 3-7.1 Bldg. Address Number Posted and Legible —N/A 2 r4' -F r 4-41% CITY OF SANFORD FIRE DEPARTMENT 1303 South French Avenue Sanford, Florida 32771 407) 302-1091 (407) 302-1097 FAX Plans Review Sheet Date: 11/9/98 Business Address: 2020 McCraken Occ. Chap. 8; 26 Business Name: Calvary Temple of Praise Ph. Contractor: Collage Design, Inc. Ph. 829-2257 Reviewed [ ] Reviewed with comment [ X ] Rejected[ ] Reviewed by: Bart Wright, Fire Protection Inspecto> b Uu5t- tt f Qat Comment. Sit,Aian and approvaus not granted at timeµof this, review 1.1 Application - New Business1735 sq ft.; New Assembly 9397 sq. ft. 1. 2 Mixed - N/A 1. 3 Special Definitions - N/A 1. 4 Classification of Occupancy - Assembly; Business 1. 4.1 Sub -classification - Class "A" > 1,000 1. 5 Classification of Hazard of Contents - Ordinary 1. 6 Minimum Construction - SBCCI Type IV Protected; LSC 101 Type I1 (000) 1. 7 Occupant Load - 1342 in assembly area; (1:7 sq. ft.; ref. No fixed seating) 2. 2 Means of Egress Components - 2.2.2.3 requires fire/exit hardware; detail,sheet omits`reference-to same; handrail at.baptismal pool shown at 32", must be 34" - 38'; pocket door (sliding type) at copy room not acceptable per 5-2.14.1 2. 3 Capacity of Egress - Section 2.3.3 requires main entrance/exit to accommodate '/z the total occupant load. Capacity of front entrance/exit i060 persons. Main entrance must be.increased. 2. 4 Number of Exits -Inadequate based an 2.3, above. (1342 occ. Load divided by 180 persons per each 3.0 opening = 7 exits 2. 5 Arrangement of Egress - Inadequate see 2.3 2. 6 Travel Distance - Inadequate see 2.3 2. 7 Discharge from Exits - as shown O.K. 2. 8 Illumination of Means of Egress - O.K. a ) , 4 wM ' `_% 2.9 Emergency Lighting - Add emergency lights to sound room and finance office; we will field verify. 2.10 Marking of Means of Egress - O.K.; field verify 2.11 Special Features -None noted 3.1 Protection of Vertical Openings - None noted 3.2 Protection from Hazards - None noted 3.3 Interior Finish - Finish schedule does not mention classification of finishes specified. Minimum is class "A" in lobby area; and class `B" elsewhere. 3.4 Detection, alarm and Communications Systems - Voice/Evac required; see LSC for full discussion of requirement. This is in addition to monitoring of sprinkler system (see 3.5"below); applicant (alarm; contractor, can verify location of FACP with AH7) 3.5 Extinguishing Requirements - Required by LSC and City Code 3.6 Corridors - N/A 4 Special Provisions 5 Building Services 5.1 Utilities 5.2 HVAC No cooking equipment noted 5.3 Elevators, Escalators, Conveyors (4A-47) 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes Sanford City Code - Chapter 9 Fire Sprinklers: Required Monitoring: Required by Central Station Listed Company Other: NFPA 1 3-5.1 Fire Lanes - N/A 3-6.4 Key Box,, -Required; field verify, 3-7.1 Bldg Address Number Posted and Legible - Required; field verify