HomeMy WebLinkAbout2 Red Cleveland Blvd Plans new construction Dollar Rent A Car Airport.. f. .. '. .. :.. ., .. -. _: .. .. .. , y ._. .. F ..... ... ... . .., . .:: as
J
I
a
I®
STORM DRAINAGE STRUCTURE SCHEDULE
FDOT
TYPE
FDOT
INDEX :NO,
TOP
- ELEV
INVERT `ELEV
COMMENTS
NORTHING.
EASTING
233
49,00
46.10
7759.80
5699.98
2
F
233
49.00
45x67 E & 43.80 S
7759.80
5572.98
3
P-5
200/211
48,65EP
43,14 N & `S
ALT B BOTTOM
7577.86
5572.98
4
P-5
200/211
49,65 EP
43.07 N & 42.52 SE
ALT B BOTTOM
7559.86
557198
5
P-5
200/211
48.85 EP
45.95
ALT, B BOTTOM
7577.86
5832,8.8`
6
P-5
200/211
48.85.:EP
45.94 N & SW
ALT ' B . BOTTOM
- '7558.86
5832.98
7 •.'
P-6
200/211
48.45 EP
45,66 NE, 42,24 NW &, S
ALT B BOTTOM `x
7469.86
5726.31
8
F
233
48,00
41.56 N & SW
7233.58
5726.31
9
EXISTr
-
44.29
40,60 NE &. SW
EXIST INLET
7018.83
5559.63
10
P-6
200/,211
49.40 EP
46.5
ALT B' BOTTOM
7469.86
5491.31.
11
F
233'
48,00
46.26 N & 45.76 SW
723358
5491.31
12 -
P-7
200/201
48.45
46.38. NW, 45.46 NE & ' 41.11 SW ,
ALT B BOTTOM, TYPE I FRAME
7123.77
5395.13"
13 '
P-5
200/211
49.35 EP
46.45
ALT B BOTTOM "
7186,18,
5346,31
14 -
P-5
200/211 '
48.05 EP
45,15
ALT B BOTTOM '_
7525,92
6077.60
15
MES
200/201
-
45.11
755831
6120.05
16 `
P-6
200/211
46.75 EP
43.85
ALT B BOTTOM
7220.08
6095,50
MES
200/201
-
43.73'
7210.11
6149.86 '
18
C
232 :
45.5.0
42.60
6813,89
5872.31 `
19 `'
P-6
200/211
47.00 EP-
42.16 NW & SW
ALT B BOTTOM
6881,61
5884,32
20`
EXIST,
- `
-
MATCH EXIST. APPROX. 41.86
REMOVE STRUCTURE '& EXTEND 'PIPE
6864.83
5869.68
21
P-6
200/211
60,18
45,42 ,
7577.86
5207.29
22_1
EXIST,
-50.20
44.94, E & W
EXIST INLET
7577.86
4976.07
23 '
P-7
2,00/201
50,60
44.25 E- & S
`- 7569.43
4,876.35
24.,
P-7
200/201 -
50.50
43.56 N & 43.06 W
=
7464.86
4876.35
25
P-6
200/211
47.50 - EP
44.10
ALT B , BOTTOM
715358
5282.31
. 26
P-6
200/211
47.50 , EP
43.91 -E & W
ALT , B BOTTOM
715 31.5 8,
.5136.31
27
P=6
- 200/211
.47.50 EP
43.27 E & 42.72 NW
ALT .B BOTTOM _
.7153.58,
4990,31
28':
P-6
:200/211
48.50 EP
42.57 BE & W
ALT, B BOTTOM
7198,36
48621,00
P76
200/211, -
48.00 EP
42.41 E & 5W
ALT, B, BOTTOM „ .
7195.36
4718.06
30
EXIST.
-
46:58
42.35 NE &` SW ;(EXISTING
EXIST INLET
7153.11
4689.7$
31
MES .
200/201
IMATCH EXIST.. APPROX, = 39.62
6672,43
6101.63
IN NO.
DRAW GPAVEMENT
_0
0 .ATE E F
0 T 0 S ;..ARE V T LI E F
TU LOCATIONS I N, 6 ST UC
AND E
, „
L45112
,
., .. -.,
•
J. .
f
OF SHEET
`
-
e.
v'
,
a
,
r v
z
- i„ t
:4
r.
c.
,
: s
,
�M1
`S 1
5
x
v
g 4
z
r qq
't �
"Ahl
0s1
no
225 AMP MAIN LUGS PANEL LP 1 A MODEL: 5QUAKt-u, Nt.Hts, IJV i i urn r ttv
14 KAIC (MIN) BOLT -ON BRANCH BREAKERS FIRST FLOOR LIGHTING TYPE: NEMA-1, SURFACE MOUNT, 42 POLE
225 AMP COPPER BUS 480'f 277 VAC, 30, 4W RATING: 65 KAIC MIN SERIES RATED.
SERVICE
LOAD
KVA
COND
DIA
WIRE
AWG
TRIP
AMPS
CKT
NO.
BRK
PLS
PHASE/
POLE #
BRK
PLS
CKT
NO.
TRIP
AMPS
WIRE
AWG
COND
DIA
LOAD
-KVA
SERVICE
LTG 102,103
2.88
1/2,
12
20
1
1
1
A
2
1
20
2.50
FUTURE CANOPY LTG
LTG 120,122,102,105
2.12
1 /2
12
20
3
1
3
B
4
1
20
2.50
FUTURE CANOPY LTG
LTG 100,106-1 14,121,STR 1
2.92
1 /2
12
20
5
1
5
C
6
1
20
2.50
FUTURE CANOPY LTG
LTG 101
3.48
1 /2
12
20
7
1
7
A
8
1
20
2.50
FUTURE CANOPY. LTG
LTG 117,1 18,101,STAIR2
3.56
1 /2 1
12
20
9
1
9
B
10
1
20
2.50
FUTURE CANOPY LTG
LTG 109
3.00
1 /2
12
20
11
1
11
C
12
2 1
12_[_20
.8
1 -1/2
2.53
PKG LOT LTG
LTG 116
3.00
1 /2
12
20
13
1
13
A
14
-
-
20
8
-
2.53
PKG LOT LTG
CANOPY LTG
3.52
1 /2
12
20
-15
1
15
8
16
2
16
20
8
1-1/2
1.38
PKG LOT LTG
CANOPY LTG
2.46
1 /2
12
20
17
1
17
C
18
-
-
20
8
1.38
PKG LOT LTG
CANOPY LTG
2.46
3/4
12
20
19
1
19
A
20
2
20
20
8
1 -1/2
1.84
PKG LOT LTG
CANOPY LTG
CANOPY LTG
1.32
2.46
-
-
12
12
20
20
21
23
1
1
21
23
8
22
24
-
2
-
24
20
20
8
8
-
1 -1/2
1.84
1.84
PKG LOT LTG
PKG LOT LTG
SPACE
0.00
25
1.84
PKG LOT LTG
SPACE
0.00
27
]A26
0.00
SPACE
SPACE
0.00
29
30
0.00
SPACE
SPACE
0.00
_
31
A
32
0.00
SPACE
SPACE
0.00
133
8
34
0.00
SPACE
SPACE
0.00
35
C
36
0.00
SPACE
SPACE
0.00
37
A
38
0.00
SPACE
SPACE
10.00
39
B
40
0.00
SPACE
SPACE
0.00
41
C
42I
L
1 0.00
1 SPACE
CONN PHASE: A: 23.03 KVA B: 18.74 KVA C: 19.09 KVA N: 23.03 KVA
CONN TOTAL: 60.86 KVA / 73.20 A x 1.25 = 91.50 A DF: 1.00
DEMAND TTL: 60.86 KVA / 73.20 A x 1.25 = 91.50 A N: 103.93 A
0 GROUND FAULT INTERRUPT CIRCUIT BREAKER
SHUNT TRIP CIRCUIT BREAKER, ONE ADDL. SPACE READ.
I
LIGHTING CONTACTOR PARKING LOT LIGHTING MARK LC2
U�
12 POLE, 277V/60/10, 20 AMP CONVERTABLE CONTACTS
120V/60/10 COIL, ELECTRICALLY HELD, IN A NEMA-1 ENCLOSURE.
SQUARE-D, CLASS 8903, TYPE LG-120U, OR APPROVED EQUAL'
POLE
CNTC
PANEL &
POLE
CNTC
PANELc
to
NO.
TYPE
SERVICE
CKT. NO.
N0,
TYPE
SERVICE
CKT. NO.
A
1
N.O.
PARKING LOT LTG
LP1-12
2
N.O.
PARKING LOT LTG
LP1 -20
-
f
3
N.O.
PARKING LOT LTG
LP1-14
N.O.
PARKING LOT LTG
LP1-22
.„
. �.
...
,:
:'.
�.
,.
,' ,,, ..
F, ..: ..
�'
\.
', ,. ,
,.. . - ,.
'-,-
_:
,, .. ::-
..
_�
_ _ ,
1 1/Z' PRE -FORS`" tE® METAL
CONC. FOOTING - SEE 5TRUC.
DU)G'S. FOR 51ZE 4 REINF,
4' CONC. SLAB W14?Xb
10/10 LUIP. ON & MIL. VAPOR
5ARRIER W1 TERMITE TREATED
CLEAN COPAPACTED EARTH FILL
77777
.,
30'-011
SL/
F _j F-5 F-5 —11
II II
I,
II I
II II
11 II
I1 II
I
ll CAR WASH �l
5LAB
,I II
I1 F-I Fin. Floor Elev. 100.0' I)
I
,I II
II II
I
II II
II
F-5 � �I
------ F-1- ----
12" 28' -0"
F-1
MONOLITHIC 5LA3 PLAN FOR GAR WASH
SCALE 1/8" = 1'-0"
a
I
MONOLITHIC CONCRETE SLAB PLAN
SCALE 1/6" = 1'-0"
i
BOLTS BY MFG.
(0" GONG. SLAB
S HAIRPIN X 20'
3 S GONT.
/_ (o 05 X ' `'t'2 11
r — _
314011 5 05X 3( 11
DETAIL F-L
S HAIRPIN (TYP.)
•: 1 . a - -
4 05 X 30"
4 '0 5 X 30"
_ 31_011
DETAIL F-3
*5 HAIRPIN ITYPJ
(o PrO X 42 " E A. WY.
DETAIL F-5
-i05 X42"
41-011 DETAIL F-4
FOOTiNG DETAILS
SCALE 3/6" = I'-0"
FOOTING SCHEDULE
MARK
WIDTH
LENGTH
REINFORCING NOTES:
F-1
1'-0"
CONT.
3 05 CONTIN. 03 is 48" C/C
F-2
3'-6" .
4'-0"
5 05 L.W. t 6
F-3
V-0"
V-0"
4 S. EA. WY.
F-4
4'-0"
5'-011
6 "5 L.W. t 1 05 S.W.
F-5
4'-0"
4'-0"
6 05 EA. WAY
HAIRPINS TO BE 05 X 20' BENT AROUND COLUMN
ANCHOR BOLTS.
Maw
35'-0"
12"
L
STRUCTURAL DESIGN CRITERIA
CODES:Standard Building Coda, 1991 Edition
Building Code Requirements For Reinforced Concrete (ACI 318-6S)
Specifications for Structural Concrete for Building (ACI 301-89)
,415C Manual of Steel Construction (Ninth Edition)
�.
2OPSF
'N1
1\';
LiVE LOADS:ROOF:
125 F'SF
La
Floor:
.�
jn N
WIND LOADS:
(5B.C.)WInd Velocity 100 M.P.N., Use Factor: 1.0
z
CONCRETEAII Concrete 3000 PSI
W
�'
ill
LU
STRENGTHPea Gravel Concrete for Filled Cells Only 2000 PSI
*28 DAYSaDo not use for Concrete Columns or Tis Beams)
LU >
LU
REINFORCING: Welded wire fabric shall conform t., ASTM A185
All barsASTM 615-60 60,000 PSI
:5 j LL
V
reinforcing
All tIa6ASTM 615-40 40,000 PSI
U)
' C3
stirrups and
LU cc
SOIL BEARINGAIIowa ble Boll bearing pressure
2500m PSF
LU 10
VALUE:after compaction:
�.'
Sea Soils Report and Specifications for Compaction requirements.
I
STRUCTURAL NOTES
W
C
®U)
CONCRETE:
All concrete shall be poured In accordance with the ACI 318-8S Code, ACI 301 Specifications,
Recommended Practice for Measuring, Mixing,
and ACI 304-6S Proposad Revision and
Transportation, and Placing Concrete. All Concrete shall place with slump per Specifications.
Areas In
Concrete Slabs on fill shall be poured on soil compacted as per 6011 engineer's report-
LL
excess of 600 square feet shall have control joints between construction joint. Maximum slump
For concrete case In footings and for slabs on grade shall be 4". Vapor barrier beneath concrete
slabs on grade shall be 6 mil polyethylene.
1.
All slabs on grade should be 4" thick, reinforced with 6x6 / WI.4 x WiA WWF placed in the
upper third unless otherwise indicated.
PUMPED CONCRETE:
IF the contractor uses a concrete pump, a concrete pump design mix and type of equipment to
1
Z
be used shall be submitted for review. All slumps and testing for pumped concrete shall be
W
Q
taken at the discharge end of the hose.
o
REINFORCING STEEL
00
4-j CD
00
M
U
All reinforcing steel shall be new deformed bars fray From rust, scale and oil and shall meet
4+
W
ASST. A-615. ReinForcing for Footing$ shall be supported on precast concrete pads, top
CC/r7
Q
reinforcing shall be positively supported by temporary stringers. Dowels For columns and Filled
U
cells shall be secured in place by using additional cross -reinforcing tied to footing reinforcing.
the
r-
CD
Splices in reinforcing where permitted shall be the following minimum, except as shown on
drawings:
r—
W
Footings, Walls, Columns, B®ams, Slabs26 dia. or 2'-0 min.
Cn
q
Welded Wire Mesh ------------------- 8"
�
Q
Temperature Reinforcing - ---20 dia. or P-0 min.
CONCRETE COVERAGES:
w �-
Footings: Top --------------- 2" clr.
_Q
-
a
Bottom and unformed edges --- 3" clr.M
u
MEMO
Slabs: Top and bottom reinforcing---- 3/4 clr.
Q �,
W
Shop Drawings for bar placement shall be submitted For review prior to Fabrication.
o (In
EMr_3EDMENTS SLEEVES, AND OPENINGS:
U
�" CIO o
IM
vi
�? W
it is the responsibility of the Contractor to coordinate the location and installation of anchorage
U N
Q
4
devices cast into the structural frame for the support of the material and equipment that is
iLn
furnished and installed by various trades. Provide dovetail anchor slots where shown on the
drawings. All shall be spaced not less than 4 diameters on center, and outside diameter shall
U~;
not exceed i/3 the slab thickness. Aluminum pipe or condult shall not be embedded In
W
a
d
concrete. All penetrations through beams and slabs must be sleeved.
Q
U
Q.
Pitch concrete slabs where required for drainage. Concrete shall not be less drawings.
Cora drilling will not be permitted.
drawings larger than 1 h'? " O.D. shall
ILSleeves
N '
or condult not shown on the structural and
Q
i1j
reeive written approval prior to placement. Sleeves shall be located a minimum of 1'-0" from
c
I -
d '
the face of any column. Sleeves shall be spaced a minimum of 3 diameters O.D_
D
All anchors , inserts, and plate embeds for the support of steel shall be placed in accordance
with these drawings.
11VLiJUVp�
.:.;
�80 wan ast falrbankft evaonua auito
Wl��7ER PARK FLORDA 3e7188 TEL �407-8•4y-8�38
l
I
4
PROVIDE 3/4" SHUT—OFF VALVE AND
UNION AT CONNECTION TO HEATER.
HOT WATER SUPPLY LINE, SIZE AS
LISTED ON PLAN.
PROVIDE RELIEF VALVE, SIZED FOR
150 PSI WORKING PRESSURE PER
ASME STANDARDS.
ELECTRICAL PIGTAIL AND RECEPTACLE
PROVIDED BY ELEC CONT, COORDINATE
REQUIREMENTS AND. LCN WITH G.C.
ELECTRIC WATER HEATER AS SPECD.
DRIP PAN MADE OF 18 -Ga. GALV.
STEEL, PROVIDED BY PLUMBER
COLD WATER SUPPLY LINE, SIZE AS
LISTED ON PLAN.
PROVIDE 3/4" SHUT—OFF VALVE,
UNION AND 1 /2" DRAIN VALVE AT
CONNECTION TO WATER HEATER.
RELIEF VALVE DISCHARGE LINE AND
DRAIN LINE ROUTED THROUGH FLOOR
AND OUT OF BUILDING AT REMOTE
LOCATION. COORDINATE LCN WITH
G.C. AND OWNER.
UNDER COUNTER ELECTRIC
WATER HEATER DETAIL
(N.T.S.)
PLUMBING FIXTURESCHEDULE
-
--
P1
HANDICAP WATER CLOSET — FLUSH VALVE, TYPE: UNIVERSAL—RUNDLE, 1.5 GPF
P9
SINGLE COMPARTMENT SINK: ELKAY MODEL No: ECC-2522, 20 GA., 302 SST, SELF
VITREOUS CHINA WATER SAVER TOILET, 16 HIGH, COLOR — WHITE
RIMMING,. 3-1/27 DRAIN OPENING, 3 HOLES ON 4+CENTERS.
SEAT: CENTOCO MODEL 500 SERIES, OPEN FRONT SEAT, COLOR — WHITE.
FAUCET: T&S BRASS MODEL No: B-865-4, g CENTERS, HOT & COLD INLETS.
FLUSH VALVE: ZURN MODEL TO MATCH W.C.., 1" IPS SUPPLY, CHROME FINISH.
.1/2"
6" GOOSENECK, CHROME FINISH
GRID.` DRAIN: ELKAY MODEL No: LK-35, 1-1 /2" TAILPIECE.
P2A
WATER CLOSET - FLUSH VALVE FLOOR MOUNT TYPE: UNIVERSAL—RUNDLE, 1.5 GPF
STOPS: 3/8" SOLID BRASS CHROME PLATED.
P—TRAP. 1-1 /2" CAST BRASS (17 GAUGE), CHROME PLATED.
VITREOUS CHINA WATER SAVER TOILET, 18" HIGH, COLOR — WHITE
SEAT: CENTOCO MODEL 500 SERIES, OPEN FRONT SEAT, COLOR — WHITE.
FLUSH VALVE: ZURN MODEL TO MATCH W.C., 1" IPS SUPPLY, CHROME FINISH..
EWH1
ELECTRIC WATER HEATER — 15 GAL: RHEEM MODEL No: EGSP-15, POINT —OF —USE
TYPE, 2-3000 WATT HEATER ELEMENTS, WIRED FOR NON —SIMULTANEOUS OPERATION,
P3
HANDICAP URINAL: UNIVERSAL—RUNDLE MODEL No: UR-4993, BALI VITREOUS
208 VOLT SINGLE PHASE, WTIH WALL MOUNT KIT(AS-36111A) AND THERMOSTATIC
CONTROL SET FOR 120 DEGREE OUTLET TEMPERATURE.
CHINA WATER SAVER SIPHON JET URINAL WITH FLUSHING RIM, INLET: 3/, "
SPUD, OUTLET: 2' N.P.T. INSIDE THREADED CONNECTION, COLOR — WHITE.
FLUSH VALVE: ZURN MODEL: Z-6003, SUPPLY: 3/4" IPS, CHROME.
FD
FLOOR DRAIN — 6" DIA (ROUND FACE) STRAINER: ZURN MODEL No: ZB-415—P—
CARRIER SYSTEM: ZURN MODEL No: Z-1222, PLATE TYPE WITH BEARING PLATE,
1 /2', D.C.C.I. BODY ASSEMBLY, POLISHED BRONZE TOP, 1 /2" TRAP PRIMER
FLOOR MOUNTED URINAL SUPPORT.
CONNECTION, WITH CAST IRON DEEP SEAL TRAP ZURN MODEL No: Z-1000.
PROVIDE PIPE SIZES AND AUXILIARY INLETS (AND SIZES) AS LISTED ON PLAN.
P4
HANDICAP LAVATORY — WALL HUNG: UNIVERSAL—RUNDLE MODEL No: U—R 4642,
CLAYTON VITREOUS CHINA, FOR CONCEALED ARM CARRIER, 4" CENTERS, WHITE.
HB
HOSE BIBB: WOODFORD MODEL No: 24P, SOLID BRASS, 3/4" FPT SUPPLY
FAUCET: SYMMONS MODEL No: S-60—H, 4" CENTER, SLOW —CLOSING OMNI
CONNECTION, WITH VACUUM BREAKER.
TEMPERATURE METERING FAUCET, 3/8" O.D.INLETS, BLADE HANDLES, CHROME.
GRID DRAIN: McGUIRE MODEL No: 155WC, 1-1 /4" OFF —SET TAILPIECE.
STOPS: 3/8" SOLID BRASS CHROME PLATED STOPS.
P—TRAP: 1-1/4" CAST BRASS (17 GAUGE), CHROME- PLATED P—TRAP.
CONCEALED ARM .CARRIER: ZURN MODEL No: Z-1231 OR Z-1231 —D FOR BACK—TO—
BACK INSTALLATIONS.
INSULATE HOT AND COLD WATER SUPPLY LINES AND WASTE CONNECTION WITH TRAP
WRAP KIT 500R, OR McGUIRE EQUAL.
P4A
LAVATORY — WALL HUNG: UNIVERSAL—RUNDLE MODEL No: U—R 4642,
CLAYTON VITREOUS CHINA, FOR CONCEALED ARM CARRIER, 4' CENTERS, WHITE.
FAUCET: SYMMONS MODEL No: S-60—A, 4' -CENTER, SLOW —CLOSING OMNI
TEMPERATURE METERING FAUCET, 3/8" O.D. INLETS, CHROME.
GRID DRAIN: McGUIRE MODEL No: 155A, 1-1/4" STANDARD TAILPIECE.
STOPS: 3/8" SOLID BRASS CHROME PLATED STOPS.
P—TRAP: 1-1/4" CAST BRASS (17 GAUGE), CHROME PLATED P—TRAP.
CONCEALED ARM CARRIER: ZURN MODEL No: Z-1231 OR Z-1231—D FOR BACK—TO—
BACK INSTALLATIONS.
REFER TO SPECIFICATIONS FOR
ADDITIONAL
REQUIREMENTS
7" onl n WATC0 AIAIAI Tn of m runtn
, r
Plumbing Life Legend
:.
01129 "
Floor Plan
-- — — Roof Plan
Cold Water, Supply
, ,
y
.
a\
--- ---- Cold Water Line, Underground
— 116 F Hot Water, Supply,
— — — -- — — -- Sanitary Sewer Vent
Sanitary Sewer Line
�.
1-1 /2" VENT THROUGH ROOF WITH WEATHER TIGHT
FLASHING AND PIPE SUPPORT AS REQUIRED BY
LOCAL CODES. ENSURE STACK EXTENDS MORE THAN
10" ABOVE ROOF.
1 —1 /2" VENT THROUGH ROOF WITH WEATHER TIGHT
FLASHING AND PIPE SUPPORT AS REQUIRED BY
LOCAL CODES. ENSURE STACK EXTENDS MORE THAN
10" ABOVE ROOF.
1-1/2� 1
� I
I i i
1-
3„ I 11 —1 /2' I P4A
i
I I ;
FD I '4 ( 2
P2A 2 P3
3" P4
2
3„
"
1 2" 4"
P1T
`4„
!'
►N
4"
Fuel Service Building
P1
3"
Verrando Engineering,, Co.
325 S.Y. 60th Avenue, Ocala, FL 34474
904/854--2664 FAX; 904/237-5217
PROJECT: 0341 DRAWING No: 02561 PLOTDATE: 10-31--95
FD
WINTER PARK, FLORIDA $2780 TEL. 407-e47-ee3e
1
,
F
01698
SUSPEND FAN FROM BUILDING STRUCTURE
USING THREADED ROD OR GALVANIZED
STEEL STRAPS.
GALVANIZED STEEL DUCT, SIZE
AS SHOWN ON PLANS AND PER
SPECIFICATIONS.
FLEXIBLE BATT INSULATION
PER SPECIFICATIONS
GYPSUM BOARD CEILING PER---'
ARCHrrECT'S DETAILS.
MOUNTING ANGLE AS PROVIDED BY
MANUFACTURER.
COORDINATE FAN LOCATION IN THE FIELD
WITH INSTALLED CEILING GRID LAYOUT TO
ENSURE FAN IS CENTERED ON LIGHT FIXTURE
BETWEEN WALL AND LIGHT.
RESTROOM EXHAUST FAN AS LISTED ON
SCHEDULE. PROVIDE TIME DELAY OFF RELAY,
SQUARE-D MODEL NO: JCK-27 WITH BASE, OR
APPROVED EQUAL. CONNECT TO SWITCHED
LIGHTING CIRCUIT IN RESTROOM PER ELECTRICAL
PLANS. FAN SHALL OPERATE FOR 10 MINUTES
AFTER LIGHT SWITCH HAS BEEN SHUT OFF.
RESTROOM EXHAUST FAN DETAIL
(N.T.S.)
N
01698
SUSPEND FAN FROM BUILDING STRUCTURE
USING THREADED ROD OR GALVANIZED
STEEL STRAPS.
GALVANIZED STEEL DUCT, SIZE
AS SHOWN ON PLANS AND PER
SPECIFICATIONS.
FLEXIBLE BATT INSULATION
PER SPECIFICATIONS
GYPSUM BOARD CEILING PER---'
ARCHrrECT'S DETAILS.
MOUNTING ANGLE AS PROVIDED BY
MANUFACTURER.
COORDINATE FAN LOCATION IN THE FIELD
WITH INSTALLED CEILING GRID LAYOUT TO
ENSURE FAN IS CENTERED ON LIGHT FIXTURE
BETWEEN WALL AND LIGHT.
RESTROOM EXHAUST FAN AS LISTED ON
SCHEDULE. PROVIDE TIME DELAY OFF RELAY,
SQUARE-D MODEL NO: JCK-27 WITH BASE, OR
APPROVED EQUAL. CONNECT TO SWITCHED
LIGHTING CIRCUIT IN RESTROOM PER ELECTRICAL
PLANS. FAN SHALL OPERATE FOR 10 MINUTES
AFTER LIGHT SWITCH HAS BEEN SHUT OFF.
RESTROOM EXHAUST FAN DETAIL
(N.T.S.)
N
b
p
a4
v4
4
p
p
b
p
p
v
v
b
` b
O
1
.
v�
v�
4
p
b
p
b
p
v
v�
CONCRETE BLOCK WALL PER
ARCHITECTS DETAILS.
PROVIDE GALVANIZED STEEL WALL
CAP FOR DUCT SIZE; LISTED ON
PLAN, MOUNTED AT ELEVATION
LISTED ON PLAN OR AS DETER-
MINED BY ARCHITECT IN THE
FIELD.
OPENING SIZED PER MANU-
FACTURER'S SPECIFICATIONS.
SEAT FLANGE IN BED OF
POLYURETHANE CALKING
COMPOUND. ENSURE ALL
JOINTS ARE WATER TIGHT.
STUCCO (WHERE SPECIFIED
BY ARCHITECT).
WINDOW SILL AS SPECIFIED BY ARCH.
CONCRETE LINTEL PER ARCHITECTURAL
DETAILS, COORDINATE WITH G.C. FOR
OPENING SIZE AND HEIGHT
PACKAGE TERMINAL HEAT PUMP
(PTHP) UNIT AS SPECIFIED, REFER
TO EQUIPMENT SCHEDULE AND SPECS
FOR ADDITIONAL REQUIREMENTS.
ELECTRICAL POWER RECEPTACLE FOR
HEAT PUMP, TO BE INSTALLED IN WALL
BELOW UNIT AS SHOWN. UNIT TO BE
PROVIDED WITH APPROPRIATE PIGTAIL
FOR VOLTAGE AND AMPERAGE OF UNIT.
COORDINATE RECEPTACLE REQUIREMENTS
WITH ELECTRICAL CONTRACTOR.
ELECTRICAL CONTRACTOR TO PROVIDE
RECEPTACLE TO MATCH HEAT PUMP
COORDINATE NEMA CONFIGURATION AND
PLUG TYPE PRIOR TO INSTALLATION
REFER TO ELECTRICAL PLANS FOR
CIRCUIT REQUIREMENNS.
ELECTRICAL CONTACTOR TO PROVIDE
CONDUIT CONNECTION TO UNIT FROM
THERMOSTAT. COORDINATE CONDUIT
CONNECTION AND T-STAT LOCATION
WITH ELECTRICAL CONT. IN THE FIELD.
02073
U U U U U U U
I}K w Q}C
T
T I T i
• •
PTAC UNIT SCHEDULE
MARK PTAC1 PTAC2 PTAC3
MANUFACTURER_
TRANE
TRANE
TRANE
MODEL NO.
PTEB 15
PTEB 15
PTEB 09
TYPE
STRAIGHT DX.
STRAIGHT . DX.
STRAIGHT DX.
FAN (58' LAT):
AIRFLOW CFM
260
260
215
SPEED
HIGH
HIGH
HIGH
FRESH AIR CFM
55
55
40
COMPRESSORS:
NUMBER
1
1
1
CAPACITY STEPS %
0-100
0-100
0-100
COOLING:
CAP. ® ARI MBH
14.60
14.60
9.10
EER / SEER
8.9/NA.
8.9/NA.
10.4/NA,
HEATING:
CAPACITY MBH
14.10
9.90
8.50
C.O.P. / H.S.P.F.
1.00/NA,
1.00/NA,
1,00/NA,
ELECTRICAL:
VOLTS/PH/HZ
208/1/60
208/1/60
208/1/60
SUP HEAT KW
3.75
2.63
2.50
HTR. MODEL NO.
NA.
NA.
NA.
CONNECTION TYPE
SINGLE PT.
SINGLE PT.
SINGLE PT.
DEMAND KW
4.61
3.25
2.80
MCA AMPS.
27.7
19.5
16.8
BKR AMPS,
30
20
20
PHYSICAL:
DIM, HxWxL
16x22x43
16x22x43
16x22x43
WEIGHT LBS. 1.59 159 1.1.31
NOTES:
1.
2,
3.
C Plan 1!8®� it -ow
d
Wz
Q
4
�•
IL
66;
X
Verran'do
Engineering,Co.
325 S.W. 60th
Avenue, Ocala, FL 34474�
a"
,.
04/$54--2
9 664
F
FAX: 904/237-�5217
�
PROJECT: 0341 DRAWING
No: 02650 PLOTDATE: 10-31-95
2 E+ ®� w,�u# foirbar�6c evonuo - ouite n
WINTER PARK,FLORIDAs FLoft 2760 Tom. re or' aa� �
' #s
IT
— —
— — — —
— —
—FS
r,
PROVIDE GROUND, NEU, HOT,
HOT RETURN FOR RELAY, HOT
FOR LIGHT, IN 34' RIGID METAL
CONDUIT. PROVIDE NEMA-1
SEAL OFFS AT POWER PANEL.
Power Plan 1/8V 0 i9-O®
z
%
H
z
-
H
w
w
z
�
z
pC
z
pC
"
H
H
H
I
H
I H
JH
H
!
i : t
LOCKER/
VENDING
ROOM
I /Alf m it-111V
FUEL TANK MONITOR PROVIDED
BY OTHERS. PROVIDE 3/4"
CONDUIT `PI/ FOUR(4) WIRES
SHIELDED CABLW W/ GROUND.
MEN'S
TOILET
l_J__ -- S EIRV I C E ARE,
SUSPENDED QUAD OUTLET
TO OPERATE SHOP EUIPMENT
(DIRLLS, VACUUMS, GRINDERS ETC.)
w
u�
z
,cq
u
u}}
�
QL
0
STO R IT
I
COVER DRIVE—THRU
SERVICE AREA
2 1/8' DEEP JUNCTION BOX, BOLTED TO
BUILDING FRAME OR RIGID STRUCTURE
EMT CONDUIT SIZE AS SHOWN ON PLANS
ZINK PLATED
)PEN EYEBOLT
FLAT PLATE COVER WITH 1 /2" K.O.
10-24 THDS. a
ZINK PLATED STEEL, CORD CONNECTOR
HUBBELL NO.: SHC-1024-ZP
ZINK PLATED
NYLON CABLE TIE, 3/1 C' WIDE (MINIMUM)
SPACED EVERY 24'
STEEL CHAIN,
SINGLE JACK
RADE SIZE 16
RUBBER JACKETED CORD, 3 - 12 AWG,
(MINIMUM)
65/30 STRAND COPPER CONDUCTORS.
ALPHA NO.: 1967/3 OR APPROVED EQUAL
LOCATE EYE BOLT TO MAINTAIN BOX
LEVEL AND PERPENDICULAR TO FLOOR
ZINK PLATED
ZINK PLATED STEEL, CORD CONNECTOR
)PEN EYEBOLT
HUBBELL NO.: SHC-1024-ZP
10-24 THDS.
4 11 /16" SQUARE, 2 1 /8" DEEP, STEEL
JUNCTION BOX WITH 1/2" K.O.'S
APPELTON NO.: 4SP-JD OR APPROVED
EQUAL.
lol
I /2" RAISED, 2 DUPLEX RECEPTACLE
col
COVER. APPELTON NO.: 8492, OR
it 11
APPROVED EQUAL
0 0
-
DUPLEX RECEPTACLE, 15 AMP, 120 VOLT
MINIMUM
COORDINATE MOUNTING HEIGHT WITH OWNER
Verrando
Engineering, Co.
325 S.W. 60th
Avenue, Ocala, FL .34474
SUSPENDED
QUADRUPLEX RECEPTACLE
904/654-2664
FAX: 904/237-5217
DETAIL
(N.T.S.)
PROJECT: 0341 DRAWING
No:. 02543 PLOTDATE: 11—01-95
FS 1 !29
I
2003 wrest !alrb+anke. avenue suites
WINTER PARK, FLORIDA 32760 TIC 407-047-60015
u i
:
225 AMP MAIN BREAKER PANEL 71 MODEL: SQUARE-D, NQOD, BOTTOM (FEED
10 KAIG (MIN) BOLT -ON BRANCH BREAKERS TYPE: ' NEMA-3R, SURFACE MOUNT, 42 POLE
225 AMP COPPER BUS 208Y 120 VAC, 30, 4W RATING: 10 KAIC MIN FULLY RATED.
SERVICE
LOAD
KVA
COND
DIA
WIRE
AWG
TRIP
AMPS
CKT
NO,
BRK
PLS
PHASE/
POLE #
BRK
PLS
CKT
NO.
TRIP
AMPS
WIRE
AWG
COND
DIA
LOAD
KVA
SERVICE
FUEL DISP. #1
1.80
3/4
12
20
1
1
1
A
2
1
2
20
12
3/4
1.80
FUEL DISPENSER #2
EWH 1
1.50
3/4
10
30
3
2
3
B
4
- 2
4
30
10
3/4
2.31
PTAC -1
-
1.50
-
10
30
-
-
5
C
6
-
-
30
10
-
2.31
-
FUEL DISP. #3
1.80
3/4
12
20
7
1
7
A
8
1
8
20
12
3/4
1.80
FUEL DISPENSER #4
OFFICE #2, STORAGE REC
0.90
1/2
12
20
9
1
9
8110
2
'10
15
12
3/4
1.63
PTAC-2
OFFICE #1 REC
1.08
1/2
12
20
11
1
11
C
12
-
-
15
12
-
1t63
-
TOILETS REC
0.72
1/2
12
20
13
1
13
A
14
2
14
20
12
3/4
0.72
PTAC-3
LOCKER ROOM REC
0.54
12
20
15
1
15
B
16
-
-
20
12
-
0.92
-
VENDING
0.18
.1/2
3/4
12
20
17
1
17
C
18
1
18
20
12
3/4
0.36
EXTERIOR RECP.
VENDING
0.18
-
12
20
19
1
19
A
20
3
20
15
12
3/4
0.94
CAR LIFT #1
VENDING
0.18
-
12
20
21
1
21
B
22
-
-
15
12
-
0.94
-
EXHAUST FANS
1.39
3/4
12
20
23
1
23
C
24
-
-
15
12
-
0.94
-
QUAD REC
0.72
3/4
12
20
25
1 1
25
A
26
3
26
15
12
3/4
0.94
CAR LIFT #2
QUAD REC
0.72
-
12
20
27
1
27
B
28
-
-
15
12
-
0.94
-
QUAD REC
0.72
-
12
20
29
1
29
C
30
-
-
15
12
-
0.94
-
TIRE BALANCER
0.20
3/4
12
20
31
1
31
A
32
2
32
30
10
3/4
1.08
FUEL PUMP
OIL PUMP
1.08
3/4
12
20
33
1
33
B
34
-
-
30
10
-
1.08
-
SPACE
0.00
1
35
C
36
0.00
SPACE
PANEL CW
9.59
Z
4/0
LUGS
37
3
37
A
38
0.00
SPACE
SUB -FEED LUGS
9.59
-
4/0
LUGS
-
-
39
B
40
0.00
SPACE
-
8.82
-
4/0
LUGS
I -
I -
1411
C
42
0.00
SPACE
CONN PHASE: A: 22.29 KVA B: 22.33 KVA C: 19.87 KVA N: 22.33 KVA
CONN TOTAL: 64.49 KVA / 179.01 A x 1.25 = 223.76 A DF: 1.00
DEMAND TTL: 64.49 KVA / 179.01 A x 1.25 = 223.76 A N:232.60 A
0 GROUND FAULT INTERRUPT CIRCUIT BREAKER
* SHUNT TRIP CIRCUIT BREAKER, ONE ADDL. SPACE REQD.
225 AMP MAIN BREAKER PANEL FS2 MODEL: SQUARE-D, NEHB, BOTTOM FEED
17 KAIC (MIN) BOLT ;ON BRANCH BREAKERS TYPE: NEMA-3R, SURFACE MOUNT, 42 POLE
225 AMP COPPER BUS 480Y 277 VAC,30, 4W RATING: 17 KAIC MIN FULLY RATED.
SERVICE
LOAD
KVA
COND
DIA
WIRE
AWG
TRIP
AMPS
CKT
NO.
BRK
PLS
PHASE/
POLE #
BRK
PLS
CKT
NO.
TRIP
AMPS
WIRE
AWG
COND
DIA
LOAD
KVA
SERVICE
AIR COMPRESSOR
2.10
3/4
12
15
1
3
1
A
2
3
2
40
8
3/4
5.82
VACUUM #1
-
2.10
-
12
15
-
-
3
B
4
-
-
40
8
-
5.82
--
--
2.10
-
12
15
-
-
5
C
6
-
-
40
8
-
5.82'
-
SERV BAY/OFF.1,2/STOR•
2.24
1/2
12
20
7
1
7
A
8
3
8
40
8
3/4
5.82
VACUUM #2
TOIL/LOCKER/FUEL STA.
1.92
1/2
12
20
9
1
9
B
10
-
-
40
8
-
5.82
-
SPARE
1.00
20 1
1
11
C
12
-
-
40
8
--
5.82
-
SPARE
1.00
20
1
13
A
14
1
20
1.00
SPARE
SPARE
1.00
20
1
15
8
16
1
20
1.00
SPARE
SPARE
1.00
20
1
17
C
18
1
20
1.00
SPARE
SPACE
0.00
19
A
20
0.00
SPACE
SPACE
0.00
21
8
22
0.00
SPACE
SPACE
0.00
23
C
24
0.00
SPACE
SPACE
0.00
25
A
26
0.00
SPACE
SPACE
0.00
27
8,28
0.00
SPACE
SPACE
0.00
29
C
30
0.00
SPACE
SPACE
0.00
31
A
32
0.00
SPACE
SPACE
0.00
33
6
34
0.00
SPACE
SPACE
0.00
35
C
36
0.00
SPACE
STEP DOWN -
21.21
1-1/4
3
100
37
3
37
A
38
0.00
SPACE
TRANSFORMER -
20.17
-
3
100
-
-
39
B
40
0.00
SPACE
NEMA-3
21.67
-
3
100
-
-
41
JC�4:2
0.00
SPACE
CONN PHASE: A: 39.19 KVA B. 37.83 KVA C: 38.41 KVA N: 39.19 KVA
CONN TOTAL: 115.43 KVA / 138.84 A x 1.25 = 173.55 A DF: 1.00
DEMAND TTL: 115.43 KVA / 138.84 A x 1.25 = 173.55 A N: 176.85 A
0 GROUND FAULT INTERRUPT CIRCUIT BREAKER
* SHUNT TRIP CIRCUIT BREAKER, ONE ADDL. SPACE READ.
225 AMP MAIN BREAKER PANEL CW MODEL: SQUARE-D, NQOD, BOTTOM FEED
10 KAIC (MIN) BOLT -ON BRANCH BREAKERS TYPE: NEMA-3R, SURFACE MOUNT, 30 POLE
225 AMP COPPER BUS 208Y/120 VAC, 30, 4W RATING: 10 KAIC (MIN) FULLY RATED.
SERVICE
LOAD
KVA
COND
DIA
WIRE
AWG
TRIP
AMPS
CKT
NO.
BRK
PLS
PHASE/
POLE #
BRK
PLS
CKT
NO.
TRIP
AMPS
WIRE
AWG
COND
DIA
LOAD
KVA
SERVICE
WASHER #1
3.04
3/4=
8
40
1
3
1
A
2
3
2
40
8
3/4
3.04
• WASHER #2
-
3.04
-
8
40
-
-
3
B
4
-
40
8
-
3.04
-
-
3.04
-
8
40
-
-
5
C
6
- I
-
40
8
- 1
3.04
-
AIR COMPRESSOR
2.10
3/4
10
30
7
3
7
A
8
0.00
SPACE
-
2.10
-
10
30
-
-
9
8
10
0.00
SPACE
-
2.10
1 -
10
1 30
-
-- -
11
C
12
0.00
SPACE
CONROLLER
1.00
3/4
12
20
13
1
13
A
14
0.00
SPACE
SPARE
1.00
20
1
15
B
16
0.00
SPACE
LIGHTING
0.64
1/2
12
20
17
1
17
C
18
0.00
SPACE
SPACE
0.00
19
A
20
0.00
SPACE
SPACE
0.00
21
B
22
0.00
SPACE
SPACE
0.00
23
C
24
0.00
SPACE
SPACE
0.00
25
A
26
.0.00
SPACE
SPACE
0.00
1
27
B
28
0.00
SPACE
SPACE
0.00
29
C
130L
0.00
SPACE
CONN PHASE: A: 9.18 KVA B: 9.18 KVA C: 8.82 KVA N: 9.18 KVA
CONN TOTAL: 27.18 KVA / 75.44 A x 1.25 = 94.31 A DF: 1.00
DEMAND TTL: 27.18 KVA / 75.44 A x 1.25 = 94.31 A N: 95.63 A
0 GROUND FAULT INTERRUPT CIRCUIT BREAKER
# SHUNT TRIP CIRCUIT BREAKER, ONE, ADDL. SPACE REQD.
3/8' = 1'-0'
3 2 1 0 3 6
2/2 10 CONCRETE TRAFFIC LID
AB' CONCRETE BLOCK SCREEN WALL WITH CAP-
\ o / I SEE CENTRAL FLORIDA TERMINALS, INC. (CFT) PLANS & SPECIFICATION
\ 9
\ / I 22 CAR WASH MACHINE (RYKO NOVA 2000, I-NS SYSTEM)
\ o
/ / , �3 RINSE WATER ARCH FRESH WATER
— I I A4 WASHWATER COLLECTION TRENCH -DROP 1/4''/1'-0'
SLOPE TO SUMP 1/4'/1'�0' - I 2/2 y A5HIGH PRESSURE/LOW VOLUME STAGE BUMP FOR FINAL RINSE
I 66 FRESH WASHWATER DISTRIBUTION MANIFOLD
I SAND TRAP DAM :��,
4 I 4' HIGH (Typical) I 4 I I OIL ABSORBANT - PILLOW, SOCK OR MAT
i I I
I I I I I A9FRESH WATER SUPPLY - 2' PVC
1050 GALLON PREFABRICATED CONCRETE ,OIL/WATER SEPARATOR
Q I I A WASTEWATER DISCHARGE TO LIFT STATION
I I 1' PVC PIPE 2SAND
WIDEP DAM
HIGH I 1' PVC PIPE
I I I N PLACE (TD P)ED I I w � I I I
a
I � I o
I I .
I I I I ( GENERAL NOTES
I I A I I A o 0 1. FLOOR CONSTRUCTIONi 5' CONCRETE SLAB 6' ABOVE GRADE REINFORCED W/6x6/
I o 0 0 o I W2,9xW2.9 WWF ON COMPACTED SUB GRADE, ASPHALT
I I I w TRANSITION TO GRADE. SEE CENTRAL FLORIDA TERMINALS,
I o I INC., (CFT) SPECIFICATION AND DRAWINGS,
I I i ti I 2. SLOPE SLAB AS REQIURED TO DRAIN, MAINTAIN MINIMUM .SLAB THICKNESS
INDICATED TYP,
I I 3. FOUNDATION DESIGN REACTION SCHEDULE- SEE CFT SHEET
4, PROVIDE ELECTRICAL SERVICE TO CARWASH STALLS AS SPECIFIED IN CFT
Ao I I o o I I o I SHEET
i 5, PROVIDE 3 PHASE, -a30V, 40 AMP SERVICE TO EACH CARWASH UNIT, 2 CARWASH
UNITS TOTAL.
a I 6. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH OF 3000 PSI
I CARWASH I A CARWASH I I IN 28 DAYS OR 2040 PSI IN 7 DAYS.
CONTROL PANEL I o I CONTROL PANEL I I 7. ALL REINFORCING BARS SHALL BE NEW BILLET STEEL GRADE 60, DEFORMED
I I IN ACCORDANCE WITH THE LATEST ASTM SPECIFICATIONS WITH DEFORMATIONS
CONFORMING TO ASTM A-615 WITH A MINIMUM YIELD STRENGTH OF 60,000 PSI,
8. DESIGN AND CONTRUCTION OF CONCRETE" SHALL BE IN ACCORDANCE WITH THE
I w I I I BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI-318-71) OR
LATEST REVISION AS PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE,
I 4 I I 9. SLAB AND SUMP HAVE BEEN DESIGNED FOR A MIN, SOIL BEARING PRESSURE
2/2 OF 2500 P.S,F,.
I o I I I IO.BACKFILL UNDER -SLABS, TANKS, AND PIPES SHALL BE COMPACTED IN LAYERS
I/ NOT OVER 6' THICK TO 99% OF THE MAX. DRY DENSITY AS INDICATED BY THE
MODIFIED PROCTOR COMPACTION TEST, (ASTM D-1557)
11.ALL PVC PIPE AND FITTINGS SHOWN ON THE DRAWINGS SHALL BE TYPE 1, SCH. 80
WHITE,
12.CARE SHOULD BE TAKEN TO PROPERLY JOIN ALL PVC PIPE AND FITTINGS FOR MAX,
STEEL GRATING W/ANGLE IRON I JOINT STRENGTH, CUT PIPE SQUARE, BEVEL, DEBURR, & CLEAN ENDS, APPLY
/ \ SEAT ANGLE FRAME EMBEDDED \ PURPLE PRIMER TO PIPE ENDS AND SOCKETS THEN CEMENT JOINTS IMMEDIATELY
1 1/2' PVC THEREAFTER,
I CORNERS OF EMBEDDED FRAME.
CONCRETE. WELD ALL .IT SHALL BE THE RESPONSIBILITY OF THE CONTACTOR TO VERIFY ALL DIMENSIONS
1/2' I . I 13AND ELEVATIONS GIVEN ON THE DRAWINGS PRIOR TO INSTALLING CONCRETE, PIPING
/ GRATING TO BE RATED FOR \ I AND EQUIPMENT.
1 1/2' CW I \ H-10 LOADING. FRAME AND �� 14.ALL PIPING TO HAVE PIPE SUPPORTS AT A MAX, OF 5'-0' SPACING.
COORDINATE LOCATIONS I GRATING SHALL BE GALVANIZED
I / STEEL AND FLUSH WITH CON- \
l CRETE SURFACE, SEE DETAIL
4 SHEET 3/3,
SHUT OFF VALVE 2 C w
AB
& VALVE BOX I \ \
ELECTRICAL SERVICE 2
SEE NOTE 5 2/2
18' 1613'-0' 2'-8' 13'-0' 16' 18'
4
3 4' 4' !
lie
a
j
PROJECT MANAGER, D . KNOTHE SCAMP AUTO RENTAL 1, INC,
" PROJECT NO:
DESIGNED 'BYE
ATL
R. DDRIA 1934 McCDY ROAD DRLANDO,, FL 32809 106705
AS Scientific Technologies, Inc. ,
. DRAWN BY e SHEET .
1120 Edgewater Drive, suite 10, Orlando Florida 32a04 CAR WASH AREA,, & WAS,FIWATER COLLECTION SYSTEM ND
SHEET CHK'D BY CAR WASH FACILITY
Phone (407) 425-5696
REV. APPROVED Br� C 1/2
❑RLANDO SANFORD AIRPORT
NOS DATE DRWN CHKD REMARKS DATE
'il
Vent"��
cU
W
U�
SLAB CROSS SECTION 2
3/8'
BUILDING
a e
4
NOTE] REFER TO ARCHITECTURAL DRAWINGS FOR p,' ,; If
ROOF -SLAB SPECS, —SCREEN WALLS A.�? ,•
d e 4 .4 _
a
17
+
�.
''
CL,�
654