HomeMy WebLinkAbout501 W 9 St Commercial review commentsCITY•OF SANFORD a BUILDING DIVISION COMMERCIAL REVIEW COMMENTS INTERIOR ALTERATIONS PROJECT: N(t _Soot . 14jk,,j_hb ✓t DATE: 4,)j..2q, (QQl ADDRESS: ,� /_ t j. 9'1 s� - SANFORD,L CONTRACTOR:,Y,,o- i/iq�i� iPAlc� Gc�jda -'LIC# eB�C.pl3�oS"Q- ADDRESS: j 16kel,e X; PHONE: (710) 74'$ ^/� SO J►�c�s�,r(i'�/ F-4 33a_18 1. Means of egress and occupant load shall comply to Section 1003 1997. S.B.C. 2 Means of egress and illumination shall comply to Section 1016.1,1016.2 and 1016.3 signs), 1997 S.B.C. 3. All corridors shall be a minimum of 4411, Table 1004,1997, S.B.C. LCOfY -er' 4. All restrooms shall comply to 1997, H.C.F.S, 553, Part 5. A 5. Interior finishes shall comply to Sec. 704, Table 803.3,1997, S.B.C. y)< 6. All electrical wiring service & fixtures shall comply to 1996, N.E.0 and Notice L amendments. -j- 7. All plumbing shall comply to 1994,S.P.C. 8. All mechanical equipment & duct systems shall comply to 1997, S.M.C. & 1997, Florida Energy Code. �8► 9. Firewalls or tenant separations shall comply to Table 413.3 & Table 704.1 & 704.1.4, penetrations shall be sleeved and fire caulked. F� 10. Stairs shall comply to Section 1006,1007,1007.1.2,1007.3,1007.4,1007.5,1007.5.3,1007.6,1007.7, 1007.8,1008.6, & 1015,1997, S.B.C. 11. Shall comply to 1994, N.F.P.A. -1. 12. Shall comply to Life Safety Code 101,1994. 04-k bcS/ �; ►l �$ Review By: i 5 V17 REQUIRED INSPECTIONS DURING AND UPON COMPLETION OF CONSTRUCTIOZ .d��I co, 1. Footer If r f ` N ivo�. Flo 't'4 K 5 rq (A)2. Underground electrical, mechanical and plumbing �iSIpF� L ef 3. Slab 4 ged 00 12. Z F!G ,I 4. Lintel and/or tie beam O '!�J / G v�GGT 5. Rough electrical �i E G� p 6. Rough mechanical F ` (5 4 7. Plumbing rough ,F� 1 , om (� ✓ O&�// 8. Tub Set 111(aC ✓�% 9. Framing 6 g i A 10. Insulation, walls and/or ceilings 11. Electrical final, mechanical final and plumbing final �. 12. Building final Date: ✓/ Signature: CITY OF SANFORD BUILDING DEPARTMENT SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PERMIT 000"1. Two (2) complete sets of plans and drawings to scale and to include; a. Site plan approved by Planning & Zoning and City Commission b. Boundary and building location survey C. Foundation plan d. Floor plan 1. Room or space identification 2. Indicate room dimensions 3. Specify door and window dimensions and types a 4. Indicate tenant separation and fire resistant walls. Complete UL design noted. -�'"- e. Four (4) or more elevations including finish floor(s) elevations, o f. Structure details -signed and sealed by engineer g. Architectural drawings signed and sealed by architect h. Electrical drawings -signed and sealed by engineer, if over 600 amps i. Mechanical drawings -signed and sealed when 15 tons or more and/or $5,000.00 .�i— j. Plumbing drawings -signed and sealed, shall comply to Florida Handicap Code. X 2. Plans shall show: 900' a. Square Footage b. Type of construction C. Occupancy classification (group) d. Occupant load e. Sprinklers, standpipes and alarm systems f. Fire protection requirements & NFPA requirements g. Life safety Code 101 -9 3. Three (3) sets of Florida Energy Forms 40OD-97 signed and sealed by architect or engineer. ffr-- 4. Arbor permit when trees are to be removed from property. Contact the City Engineer for details regarding the Arbor Ordinance and permit. e— 5. Soil analysis may be included on site plan or foundation -B-" 6. Soil analysis and/or soil compaction report. If soils appear to be unstable or if structure to be built on fill, a report may be requested by the Building Official or his representative. Utility Letters Required Inspections During and Upon Completion of Construction 1. Footer 2. Underground electrical, mechanical and plumbing 3. Foundation elevation survey 4. Slab 5. Lintels -tie beams-columns-cetls 6. Rough electrical 7. Rough mechanical 8. Rough plumbing 9. Tub Set 10. Framing 11. Tenant separation/firewall 12. Insulation, walls and/or ceilings 13. Electrical final, mechanical final, and plumbing final 14. Building final 15. Other OY sy DATE T SIGNATURE (By Owner or Authorize Agent) x'r CITY OF SANFORD FIRE DEPARTMENT 1303 South French Avenue Sanford, Florida 32771 (407) 302-1091 (407) 302-1097 FAX Plans Review Sheet Date: July 30, 1999 Business Address: SUI Business Name: Bell South Mobility Ph. Oce. Chap. 26 Contractor: H.E. Hennigh, Inc. Ph. (904) 757-3111 Reviewed [ ] Reviewed with comment C=. Rejected Reviewed by: Bart Wright, Fire Protection Inspector Comment: Reference letter dated 4/22/99 from Smoak Designs 1.1 Application — Renovation to existing business occupancy 1.2 Mixed - N/A 1.3 Special Definitions - N/A 1.4 Classification - Business 1.5 Classification of Hazard of Contents - Ordinary 1.6 Minimum Construction — N/R; 1.7 Occupant Load — 1/100 (egress capacity) 2.2 Means of Egress Components - O.K. 2.3 Capacity of Egress - O.K. 2.4 Number of Exits - O.K. 2.5 Arrangement of Egress - O.K. 2.6 Travel Distance - O.K. $f i R2.7 Discharge from Exits - O.K. 2.8 Illumination of Means of Egress - O.K. 2.9 Emergency Lighting - O.K.; will field verify 2.10 Marking of Means of Egress - O.K. for all uses; will field verify 2.11 Special Features -None noted 3.1 Protection of Vertical Openings — None noted 3.2 Protection from Hazards — N/A 3.3 Interior Finish - Class "C" 3.4 Detection, alarm and Communications Systems — N/R 3.5 Extinguishing Requirements — N/R 3.6 Corridors - N/A - 4 Special Provisions - None noted - 5 Building Services No comment 5.1 Utilities - 5.2 HVAC 5.3 Elevators, Escalators, Conveyors (4A-47) 5.4 Rubbish Chutes, Incinerators, and Laundry Chutes Sanford City Code - Chapter 9 Fire Sprinklers: N/R Monitoring: N/R Other: NFPA 1 3-5.1 Fire Lanes — N/A 3-6.1 Key Box - required; will field locate 3-7.1 Bldg. Address Number Posted and Legible — will field verify