HomeMy WebLinkAbout301 Towne Center Blvd 96-1910 004126 Burger King indoor PlaygroundCITY OF SANFORD
FIRE DEPARTMENT
300 N. Park Ave.
Sanford, FL 32771
407) 302-2520 (407) 330-5677 FAX
Plans Review Sheet
Date: September 26, 2000 Business Address:301 Town Center Blvd..(Occ.
Assembly (Ch. #8) Business Name: Burger King Ph. (305) 378-3250
Contractor: Gershen Associates Ph. Unk
Reviewed [ ] Rid- ed 71thI to IN en[ ] RejectedritX
Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner
Comment: Post new occupancy load sign in a visible location per the engineer's
calculations on the blue prints (See page A-1) .
Fire Protection Systems: No new system installed.
7
Whole Building Performance Method for Commercial Buildings
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
W- Florida Department of Community Affairs
FLA/COM-97 Version 2.2
PROJECT NAME_BK 09975 PLAYGROUND ADDITIO
ADDRESS: 301 TOWNE CTR BLVD
SANFORD, FL.
OWNER: _BURGER KING CORP.
AGENT:
BUILDING TYPE: _Restaurant < 100 People_
CONSTRUCTION CONDITION: Existing Building
DESIGN COMPLETION: _Addition
CONDITIONED FLOOR AREA: _539
MAX. TONNAGE OF EQUIPMENT PER SYSTEM:
COMPLIANCE CALCULATION:
Form 40OA-97
PERMITTING OFFICE:
Sanford
CLIMATE ZONE: 5
PERMIT NO: 00-
JURISDICTION NO: 691500
5.
NUMBER OF ZONES: 1
METHOD A DESIGN CRITERIA RESULT
A. WHOLE BUILDING 68.54 100.00 PASSES
PRESCRIPTIVE REQUIREMENTS:
LIGHTING
LIGHTING CONTROL REQUIREMENTS PASSES
HVAC EQUIPMENT
COOLING EQUIPMENT
1. SEER 11.00 9.70 PASSES
HEATING EQUIPMENT
1. Et 1.00 N/A
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS
1. Unconditioned Space 4.20 4.20 PASSES
REHEAT SYSTEM TYPES USED
NO REHEAT SYSTEM is USED
WATER HEATING EQUIPMENT
PIPING INSULATION REQUIREMENTS
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
specifications covered by -this calcu-
lation are in compliance with the
Florida Energy Efficiency Code.
PREPARED BY:
DATE:
I hereby certify that this building is,
in compliance with the Florida Energy
Efficiency Code.
OWNER/AGENT:
DATE: .,
G"
I hereby certify(*) that the'system design
Review of the plans and specifica-
tions covered by this calculation
indicates compliance with the
Florida Energy Efficiency Code.
Before construction is completed,
this building will be inspected
for compliance in acc _ewtfi
Section 553.908, F tutes.
BUILDIN OFFICIAL:
DATE: -ZT3 -bco
is in compliance with the Florida
Energy Efficiency Code.
SYSTEM DESIGNER
ARCHITECT REGISTRATION/STATE
MECHANICAL: M eba.IPLUMBING1 (
ELECTRICAL: (_
LIGHTING I k3 V „
Signature is required where Florida law requires design to be performedbyregistereddesignprofessionals. Typed names and registration numbers maybeusedwhereallrelevantinformationiscontainedonsigned/sealed plans.
BUILDING ENVELOPE SYSTEMS COMPLIANCE
401.------GLAZING--ZONE 1------------------------------------------
q-
CHECK
v- Elevation Type U SC VLT ShadingArea(S ft)-
North Commercial 1.09 .7 .43 Continuous Ove 198SouthCommercial1.09 .7 .43 Continuous Ove 200
Total Glass Area in Zone 1 = 398
Total Glass Area = 398402.------WALLS--ZONE 1------------------------------------------------
Elevation Type U Insul R Gross(Sg ft)
South .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 355West .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 364
North .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 355
Total Wall Area in Zone 1 = 1074
Total Gross Wall Area = 1074
403------- DOORS --ZONE 1------------------------------------------------
Elevation Type U Area (Sgft)
North No doors 0.00 0
Total Door Area in Zone 1 = 0
Total Door Area = 0
404.------ROOFS--ZONE 1------------------------------------------------
Type Color U Insul R Area(Sgft)
WDTRUSSES,R-30 INS,GYP BOARD Medium .04 25 538
Total Roof Area in Zone 1 = 538
Total Roof Area = 538
405------- FLOORS -ZONE 1------------------------------------------------
Type Insul R Area(Sgft)
Slab on Grade/Uninsulated 0 538
Total Floor Area in Zone 1 = 538
Total Floor Area = 538
406------- INFILTRATION --------------------------------------------------
Infiltration Criteria in 406.1.ABCD have been met.
CH CK
MECHANICAL SYSTEMS
CHECK
HVAC load sizing has been performed. (407.1.ABCD)
407------- COOLING SYSTEMS-----------------------------------------------
Type No Efficiency IPLV Tons
1. Single Package 1 11 9. 5.00
408.------HEATING SYSTEMS-----------------------------------------------
Type No Efficiency BTU/hr
1. Electric Resistance 1 1 51000
409.------VENTILATION ---------------------------------------------------
Ventilation Criteria in 409.1.ABCD have been met. ICHECK
410------ AIR DISTRIBUTION SYSTEM----------------------------------------
CH CK
Duct sizing and design have been performed. (410.1.ABCD)
AHU Type Duct Location Rlvalue
1. Air Conditioners Unconditioned Space 4.2
CHECK
Testing and balancing will be performed. (410.1.ABCD)
411------ PUMPS AND PIPING -ZONE ----------------------------------------
Basic prescriptive requirements in 411.1.ABCD have been met.
PLUMBING SYSTEMS
411------ PUMPS AND PIPING -ZONE 1--------------------------------------- ---
Type R-value/in Diameter Thickness
1. Non -Circulating 0 75 0
412------ WATER HEATING SYSTEMS -ZONE 1---------------------------------- ---
Type Efficiency StandbyLoss InputRate Gallons
ELECTRICAL SYSTEMS
413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- --y/_KHHE
Metering criteria in 413.1.ABCD have been met.
414------ MOTORS--------------------------------------------------- --/--
Motor efficiencies in 414.1.ABCD have been met.
415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- ---
Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft)
Fast Food/ 1 On/Off 4 None 0 800 538
Total Watts for Zone 1 = 800
Total Area for Zone 1 = 538
Total Watts = 800
Total Area 538
Cr I
Lighting criteria in 415.1.ABCD have been met:
16. Operation/maintenance manual will be provided to owner.(102.1)
PROJECT TITLE BK 09975 PLAYGROUND ADDITIONPROJECT
TYPE Restaurant < 100 People
BUILDING LOCATION Sanford
BUILDING AREA (ft2) 539
HEATING ENERGY
Electric Resistance
COOLING ENERGY
Direct Expansion
Air Conditioner (PTAC)
DOMESTIC HOT WATER ENERGY
BUILDING MISCELLANEOUS
Lights
Equipment
SYSTEM MISCELLANEOUS
Fans
PLANT MISCELLANEOUS
TOTAL ENERGY CONSUMPTION :
BUILDING ANNUAL ENERGY USE
DESIGN BUILDING BASELINE BUILDING1 (o)
24.10 1 22.32
45.66
28.95 1 16.30
9.91 I 8.66
0.42 0.42
5.15 1 22.93
68.54 .1 100.00
PASSES ******
PROJECT TITLE BK 09975 PLAYGROUND ADDITION
BUILDING TYPE Restaurant < 100 People
BUILDING LOCATION Sanford
BUILDING AREA(ft2): 539
BUILDING DESIGN :
Exterior Lighting Power 0 W
EXTERIOR LIGHTING CRITERIA:
AREA AREA AREA OR ALLOWANCE
CODE DESCRIPTION LENGTH WATTS
Exterior Lighting Power Allowance 0.00 W
Not Applicable ****
LIGHTING SYSTEM CONTROL REQUIREMENTS:
SPACE NO. CONTROLS -
NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2
6 Fast Food/ 538.2 1 On/Off 4 None
PASSES ********
PROJECT TITLE BK 09975 PLAYGROUND ADDITION
BUILDING TYPE Restaurant < 100 People
BUILDING LOCATION Sanford
BUILDING AREA(ft2): 539
HVAC SYSTEM REQUIREMENTS:
TOTAL EQUIVALENT
CONTROL POINTS
NO. DESIGN CRITERIA
Oil 4 > 2
Cooling System
Type
Measure
1 #2
Minim.
1
Minim.
2
System
Eff.#1
System
Eff.#2
Result
for #1
Result
for #2
Single Pack. SEER 9.70 0.00 11.00 9.00 PASSES
Heating System Measure Minimum Req. Efficiency Result
Ele. Resis. Et 1.00 N/A
PASSES ********
AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS:
Zone # Duct Location Minimum R-Value Design R-Value Result
1. Unconditioned Space 4.20 4.20 PASSES
PASSES ********
PROJECT TITLE BK 09975 PLAYGROUND ADDITION
BUILDING TYPE Restaurant < 100 People
BUILDING LOCATION Sanford
BUILDING AREA(ft2) 539
WATER HEATING SYSTEM REQUIREMENTS
System Measure Minimum Maximum Design Design Result
Type EF / Et SL EF / Et SL
Not Applicable ****
PIPING INSULATION REQUIREMENTS:
Pipe Insulation Thickness(in)
System Type O.D.(in) Minimum Req. Design Result
Not Applicable ****
GUERREROIGONZALEZ ENGINEERS, INC.
r Michael C. Guerrero, P.E. Mechanical Engineer # 15235
V 4300 SW 73rd Ave. Suite #107A Miami, Florida 33155
Tel. (305) 262-3944 Fax. (305) 262-8211
BK 09975 Playground Addition
301 TowneCenter Blvd.
Sanford, Florida
ASHARE HANDBOOK, 1989 FUNDAMENTALS VOLUME, CHAPTER 26
COOLING LOAD CALCILATIONS: SUMMARY
CONDITIONS: INSULATION:
91 FDB, 79 FWB, OUTSIDE WALLS R-3
76 FDB, 50-60%RH, INSIDE ROOF R-19
TRANSMISSION: COOLINGLOAD, BTUH
SENSIBLE LATENT
WALLS: Q=AREA*U(THER. COEFF.)*Tdeq
Q=1074*.19*30 6122
DOORS: Q=0 0
ROOF: Q=538*.05*76 2044
GLASS: Q=398*1.1*15 6567
SOLAR INTERIOR SINGLE CLEAR
GLASS: Q=AREA*OSF*SH.COEFF.*O/H FACTOR
S Q=200*137*.7*.8 15344
N Q=198*.43*.7*.8 48
INTERNAL HEAT GAIN:
LIGHTS: Q=AREA*W/FTSQ*FACTOR
Q=538*1.8*3.4 3293
PEOPLE: Q=#PEOPLE*FACTOR
SEN. Q=16*250 4000
LAT. Q=16*230 3680
POWER: Q=AREA*FACTOR (Eq.)
Q=538*.5 269
VENTILATION:
Q=#PEOPLE*CFM*T. DIFF.*FACTOR
SEN. Q=16*20*15*1.08 5184
Q=#PEOPLE*CFM*HU.DIFF. *FACTOR LAT.
Q=16*20*50*.68 10880 DUCT
HEAT GAIN: Q=
FACTOR (R-6)*D.LG./100 Q=
1.4*900*30/100 378 TOTAL
SENSIBLE 43248 TOTAL
LATENT 14560 GRAND
TOTAL 57808 BTUH
1
G
HEATING LOAD CALCULATIONS
HEATING LOAD, KW
CONDITIO 70 FDB, INSIDE
47 FDB, OUTSIDE
HEATING:
TRANSMIT Q=AREA*U FACTOR*TEMP DIFF
GLASS: Q=374*1.13*23 9720
WALLS: Q=1054*.29*23 7030
ROOF: Q=528*.05*23 607
VENTILAT Q=FACTOR*CFM*T.DIFF./FACTOR-INTERNAL
HEAT GAIN (L.P.A.)
SENSIBLE Q=1.08*2000*.4*23-(5000+4600+4573) 5699
HUM LOA[ Q=FACTOR*SHD*CFM
Q=.67*10*2000*.4 5360
DUCT HEF Q=1.4*1200*30/100 504
TOTAL 28921
OR 9 KW
EQUIPMENT SIZING:
BASED ON THE COOLING AND HEATING LOAD CALCS.
USE 1-5 TON A/C UNIT (66,000 BTUH TOTAL/ 48,300 SEN.)
WITH A STRIP HEATERS TOTALING 10 KW.
Dfi-wia