HomeMy WebLinkAbout301 Towne Center Blvd 96-1910 004126 Burger King indoor PlaygroundCITY OF SANFORD FIRE DEPARTMENT 300 N. Park Ave. Sanford, FL 32771 407) 302-2520 (407) 330-5677 FAX Plans Review Sheet Date: September 26, 2000 Business Address:301 Town Center Blvd..(Occ. Assembly (Ch. #8) Business Name: Burger King Ph. (305) 378-3250 Contractor: Gershen Associates Ph. Unk Reviewed [ ] Rid- ed 71thI to IN en[ ] RejectedritX Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Post new occupancy load sign in a visible location per the engineer's calculations on the blue prints (See page A-1) . Fire Protection Systems: No new system installed. 7 Whole Building Performance Method for Commercial Buildings ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION W- Florida Department of Community Affairs FLA/COM-97 Version 2.2 PROJECT NAME_BK 09975 PLAYGROUND ADDITIO ADDRESS: 301 TOWNE CTR BLVD SANFORD, FL. OWNER: _BURGER KING CORP. AGENT: BUILDING TYPE: _Restaurant < 100 People_ CONSTRUCTION CONDITION: Existing Building DESIGN COMPLETION: _Addition CONDITIONED FLOOR AREA: _539 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: COMPLIANCE CALCULATION: Form 40OA-97 PERMITTING OFFICE: Sanford CLIMATE ZONE: 5 PERMIT NO: 00- JURISDICTION NO: 691500 5. NUMBER OF ZONES: 1 METHOD A DESIGN CRITERIA RESULT A. WHOLE BUILDING 68.54 100.00 PASSES PRESCRIPTIVE REQUIREMENTS: LIGHTING LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 11.00 9.70 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Unconditioned Space 4.20 4.20 PASSES REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT PIPING INSULATION REQUIREMENTS COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by -this calcu- lation are in compliance with the Florida Energy Efficiency Code. PREPARED BY: DATE: I hereby certify that this building is, in compliance with the Florida Energy Efficiency Code. OWNER/AGENT: DATE: ., G" I hereby certify(*) that the'system design Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed, this building will be inspected for compliance in acc _ewtfi Section 553.908, F tutes. BUILDIN OFFICIAL: DATE: -ZT3 -bco is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER ARCHITECT REGISTRATION/STATE MECHANICAL: M eba.IPLUMBING1 ( ELECTRICAL: (_ LIGHTING I k3 V „ Signature is required where Florida law requires design to be performedbyregistereddesignprofessionals. Typed names and registration numbers maybeusedwhereallrelevantinformationiscontainedonsigned/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE 401.------GLAZING--ZONE 1------------------------------------------ q- CHECK v- Elevation Type U SC VLT ShadingArea(S ft)- North Commercial 1.09 .7 .43 Continuous Ove 198SouthCommercial1.09 .7 .43 Continuous Ove 200 Total Glass Area in Zone 1 = 398 Total Glass Area = 398402.------WALLS--ZONE 1------------------------------------------------ Elevation Type U Insul R Gross(Sg ft) South .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 355West .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 364 North .5 STUCCO,8"CMU,R-3,.5 GYP B. .19 3 355 Total Wall Area in Zone 1 = 1074 Total Gross Wall Area = 1074 403------- DOORS --ZONE 1------------------------------------------------ Elevation Type U Area (Sgft) North No doors 0.00 0 Total Door Area in Zone 1 = 0 Total Door Area = 0 404.------ROOFS--ZONE 1------------------------------------------------ Type Color U Insul R Area(Sgft) WDTRUSSES,R-30 INS,GYP BOARD Medium .04 25 538 Total Roof Area in Zone 1 = 538 Total Roof Area = 538 405------- FLOORS -ZONE 1------------------------------------------------ Type Insul R Area(Sgft) Slab on Grade/Uninsulated 0 538 Total Floor Area in Zone 1 = 538 Total Floor Area = 538 406------- INFILTRATION -------------------------------------------------- Infiltration Criteria in 406.1.ABCD have been met. CH CK MECHANICAL SYSTEMS CHECK HVAC load sizing has been performed. (407.1.ABCD) 407------- COOLING SYSTEMS----------------------------------------------- Type No Efficiency IPLV Tons 1. Single Package 1 11 9. 5.00 408.------HEATING SYSTEMS----------------------------------------------- Type No Efficiency BTU/hr 1. Electric Resistance 1 1 51000 409.------VENTILATION --------------------------------------------------- Ventilation Criteria in 409.1.ABCD have been met. ICHECK 410------ AIR DISTRIBUTION SYSTEM---------------------------------------- CH CK Duct sizing and design have been performed. (410.1.ABCD) AHU Type Duct Location Rlvalue 1. Air Conditioners Unconditioned Space 4.2 CHECK Testing and balancing will be performed. (410.1.ABCD) 411------ PUMPS AND PIPING -ZONE ---------------------------------------- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1--------------------------------------- --- Type R-value/in Diameter Thickness 1. Non -Circulating 0 75 0 412------ WATER HEATING SYSTEMS -ZONE 1---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons ELECTRICAL SYSTEMS 413.-----ELECTRICAL POWER DISTRIBUTION---------------------------- --y/_KHHE Metering criteria in 413.1.ABCD have been met. 414------ MOTORS--------------------------------------------------- --/-- Motor efficiencies in 414.1.ABCD have been met. 415.-----LIGHTING SYSTEMS -ZONE 1--------------------------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Fast Food/ 1 On/Off 4 None 0 800 538 Total Watts for Zone 1 = 800 Total Area for Zone 1 = 538 Total Watts = 800 Total Area 538 Cr I Lighting criteria in 415.1.ABCD have been met: 16. Operation/maintenance manual will be provided to owner.(102.1) PROJECT TITLE BK 09975 PLAYGROUND ADDITIONPROJECT TYPE Restaurant < 100 People BUILDING LOCATION Sanford BUILDING AREA (ft2) 539 HEATING ENERGY Electric Resistance COOLING ENERGY Direct Expansion Air Conditioner (PTAC) DOMESTIC HOT WATER ENERGY BUILDING MISCELLANEOUS Lights Equipment SYSTEM MISCELLANEOUS Fans PLANT MISCELLANEOUS TOTAL ENERGY CONSUMPTION : BUILDING ANNUAL ENERGY USE DESIGN BUILDING BASELINE BUILDING1 (o) 24.10 1 22.32 45.66 28.95 1 16.30 9.91 I 8.66 0.42 0.42 5.15 1 22.93 68.54 .1 100.00 PASSES ****** PROJECT TITLE BK 09975 PLAYGROUND ADDITION BUILDING TYPE Restaurant < 100 People BUILDING LOCATION Sanford BUILDING AREA(ft2): 539 BUILDING DESIGN : Exterior Lighting Power 0 W EXTERIOR LIGHTING CRITERIA: AREA AREA AREA OR ALLOWANCE CODE DESCRIPTION LENGTH WATTS Exterior Lighting Power Allowance 0.00 W Not Applicable **** LIGHTING SYSTEM CONTROL REQUIREMENTS: SPACE NO. CONTROLS - NO. DESCRIPTION AREA TASKS TYPE 1 NO. TYPE 2 6 Fast Food/ 538.2 1 On/Off 4 None PASSES ******** PROJECT TITLE BK 09975 PLAYGROUND ADDITION BUILDING TYPE Restaurant < 100 People BUILDING LOCATION Sanford BUILDING AREA(ft2): 539 HVAC SYSTEM REQUIREMENTS: TOTAL EQUIVALENT CONTROL POINTS NO. DESIGN CRITERIA Oil 4 > 2 Cooling System Type Measure 1 #2 Minim. 1 Minim. 2 System Eff.#1 System Eff.#2 Result for #1 Result for #2 Single Pack. SEER 9.70 0.00 11.00 9.00 PASSES Heating System Measure Minimum Req. Efficiency Result Ele. Resis. Et 1.00 N/A PASSES ******** AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS: Zone # Duct Location Minimum R-Value Design R-Value Result 1. Unconditioned Space 4.20 4.20 PASSES PASSES ******** PROJECT TITLE BK 09975 PLAYGROUND ADDITION BUILDING TYPE Restaurant < 100 People BUILDING LOCATION Sanford BUILDING AREA(ft2) 539 WATER HEATING SYSTEM REQUIREMENTS System Measure Minimum Maximum Design Design Result Type EF / Et SL EF / Et SL Not Applicable **** PIPING INSULATION REQUIREMENTS: Pipe Insulation Thickness(in) System Type O.D.(in) Minimum Req. Design Result Not Applicable **** GUERREROIGONZALEZ ENGINEERS, INC. r Michael C. Guerrero, P.E. Mechanical Engineer # 15235 V 4300 SW 73rd Ave. Suite #107A Miami, Florida 33155 Tel. (305) 262-3944 Fax. (305) 262-8211 BK 09975 Playground Addition 301 TowneCenter Blvd. Sanford, Florida ASHARE HANDBOOK, 1989 FUNDAMENTALS VOLUME, CHAPTER 26 COOLING LOAD CALCILATIONS: SUMMARY CONDITIONS: INSULATION: 91 FDB, 79 FWB, OUTSIDE WALLS R-3 76 FDB, 50-60%RH, INSIDE ROOF R-19 TRANSMISSION: COOLINGLOAD, BTUH SENSIBLE LATENT WALLS: Q=AREA*U(THER. COEFF.)*Tdeq Q=1074*.19*30 6122 DOORS: Q=0 0 ROOF: Q=538*.05*76 2044 GLASS: Q=398*1.1*15 6567 SOLAR INTERIOR SINGLE CLEAR GLASS: Q=AREA*OSF*SH.COEFF.*O/H FACTOR S Q=200*137*.7*.8 15344 N Q=198*.43*.7*.8 48 INTERNAL HEAT GAIN: LIGHTS: Q=AREA*W/FTSQ*FACTOR Q=538*1.8*3.4 3293 PEOPLE: Q=#PEOPLE*FACTOR SEN. Q=16*250 4000 LAT. Q=16*230 3680 POWER: Q=AREA*FACTOR (Eq.) Q=538*.5 269 VENTILATION: Q=#PEOPLE*CFM*T. DIFF.*FACTOR SEN. Q=16*20*15*1.08 5184 Q=#PEOPLE*CFM*HU.DIFF. *FACTOR LAT. Q=16*20*50*.68 10880 DUCT HEAT GAIN: Q= FACTOR (R-6)*D.LG./100 Q= 1.4*900*30/100 378 TOTAL SENSIBLE 43248 TOTAL LATENT 14560 GRAND TOTAL 57808 BTUH 1 G HEATING LOAD CALCULATIONS HEATING LOAD, KW CONDITIO 70 FDB, INSIDE 47 FDB, OUTSIDE HEATING: TRANSMIT Q=AREA*U FACTOR*TEMP DIFF GLASS: Q=374*1.13*23 9720 WALLS: Q=1054*.29*23 7030 ROOF: Q=528*.05*23 607 VENTILAT Q=FACTOR*CFM*T.DIFF./FACTOR-INTERNAL HEAT GAIN (L.P.A.) SENSIBLE Q=1.08*2000*.4*23-(5000+4600+4573) 5699 HUM LOA[ Q=FACTOR*SHD*CFM Q=.67*10*2000*.4 5360 DUCT HEF Q=1.4*1200*30/100 504 TOTAL 28921 OR 9 KW EQUIPMENT SIZING: BASED ON THE COOLING AND HEATING LOAD CALCS. USE 1-5 TON A/C UNIT (66,000 BTUH TOTAL/ 48,300 SEN.) WITH A STRIP HEATERS TOTALING 10 KW. Dfi-wia