HomeMy WebLinkAbout1201 W P Ball Blvd 04-3205 04-2272 Correspondence Fire inspection Super Targetr! r SAN `FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 Plans Review Sheet Date: August 26, 2004 Business Address: 1201 W.P. Ball Blvd Occ. Ch. #36 Mercantile Business Name: Super Target and Garden Center Ph. ( ) Contractor: Eagle Fire Protection Inc. Ph. (407) 656-8387 FAX (407)656-9405 Reviewed [ ] Reviewed With Comment X ] Rejected [ ] „.. Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Instillation of Five (5) types of design area. Ordinary Hazard Group # 1, Ordinary Hazard Group Two (#2) 12' height max storage. Class IV Rack Storage 2204 total fire sprinkler head installation Application— Per N.F.P.A. #13-1999 Ed, AND BACK FLOW PREVENTER ,Contractor shall have a class # 1 and nor} #5 _ _ .,..r+nna.� ,.. .. .� •. r � ��w�..„.i&s'x�, „ t .; , n , x.. ➢ Design System #1= General Sales Area (No Stockpiles over 12') (ft) ordinary group #2 Density .3 Wet Central Model # EC-14 %" k-Factor 14 Temp. 155 Degrees ➢ Design System #3= General Sales Area (No Stock piles over 12') (ft) ordinary 13 Density .3 Wet Central Model # EC-14 %" k-Factor 14 Temp. 155 Degrees All SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2526 ➢ Design System #3A= Food Service Area (No Stock piles over 12') (ft) ordinary group #2 Density .3 Wet Central Model # EC-14 %" k-Factor 14 Temp. 155 Degrees ►: ➢ Design Systems #4= General Sales Area (No Stock piles over 12') (ft) ordinary group #2 Density .1 Wet Central Model # EC-14 %" k-Factor 14 Temp. 155 Degrees ►9 ➢ Design Systems #5= Stock Room Ceiling Height Varies Stock Height (?)Density .3 Wet Central Model #EC-14 3/a" k-Factors 14 Temp. 155 Degrees 0 ➢ Design System # 1-B Garden Center Ceiling Height varies Stock Height (12')Ord. Group #2 . Density .45 Wet Central Model #EC-25 1" k-Factors 25.2 Temp. 155 Degrees ➢ Design System #1-C "Stock Room" Ceiling Height varies Stock Height (15')ft max height ➢ Density .2 Wet Viking Model # M -1/2" k-Factor 5.6 Temp. 155 Degrees a ➢ Design System #4-A1 "Stock Room" Ceiling Height varies Stock Height 15'max height ➢ Density .45 Wet Central Model # EC-25 -1" k-Factor 25.2 Temp. 165 Degrees ➢ Central EC-14-EX-COV SSP 3/4" 155 Reek K-14 593 Heads ➢ Viking M1/2" Brass SSU 155 K=5.6 65 Heads ➢ Central EC-25-EX-COV SSU 1" 165 K-25.5 206 Heads 2 • Do not block access to hose cabinets , and fire inspector test valves 3 Component Performance Method for Commercial Buildings ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs PROJECT NAME—MDS004096 ADDRESS: OWNER: AGENT: FLA/COM-97 Version 2.2 WILLIAMS/SCOTSMAN BUILDING TYPE: Business (Office) CONSTRUCTION CONDITION: New construction DESIGN COMPLETION: _Finished Building CONDITIONED FLOOR AREA: _672 MAX. TONNAGE OF EQUIPMENT PER SYSTEM: COMPLIANCE CALCULATION: Form 40OB-97 PERMITTING OFFICE: _ORANGE COUNTY CLIMATE ZONE: 5 PERMIT NO: _ JURISDICTION NO: 581000 3 NUMBER OF ZONES: 1 METHOD B DESIGN CRITERIA RESULT ------ ----------------- ENVELOPE PERFORMANCE ------ 47.75 -------- 74.50 PASSES OTHER ENVELOPE REQUIREMENTS PASSES LIGHTING INTERIOR LIGHTING 585.60 1323.00 PASSES EXTERIOR LIGHTING 0.00 150.00 PASSES LIGHTING CONTROL REQUIREMENTS PASSES HVAC EQUIPMENT COOLING EQUIPMENT 1. SEER 10.00 9.70 PASSES HEATING EQUIPMENT 1. Et 1.00 N/A AIR DISTRIBUTION SYSTEM INSULATION REQUIREMENTS 1. Ventilated 6.00 6.00 PASSES REHEAT SYSTEM TYPES USED NO REHEAT SYSTEM is USED WATER HEATING EQUIPMENT 1. EF 1.50 0.92 PASSES PIPING INSULATION REQUIREMENTS 1. Non -Circulating w/o H 1.00 1.00 PASSES ---------------------------------------------------------------------------- COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Florida Energy"' iciency Code. PREPARED BY: DATE: U I hereby ce. 'i y that this building is in comp1i_a;:. w th 't-ne Florida Energy Efficiency ,CCcde . OWNER/AGENT: DATE: Review of the plans and specifica- tions covered by this calculation indicates compliance with the Florida Energy Efficiency Code. Before construction is completed., this building will be inspected for compliance in accordance with Section 553.908, Florida Statutes. BUILDING OFFICIAL: DATE: _ _ _ I hereby certify(*) that the system design is in compliance with the Florida Energy Efficiency Code. SYSTEM DESIGNER REGISTRATION/STATE ARCHITECT : MECHANICAL:_ PLUMBING _ ELECTRICAL:_ LIGHTING (*) Signature by registered be used where is required where Florida law requires design to be performed design professionals. Typed names and registration numbers may all relevant information is contained on signed/sealed plans. BUILDING ENVELOPE SYSTEMS COMPLIANCE CHECK 401------- GLAZING --ZONE 1 ------------------------------------------------ v- Elevation Type U SC VLT Shading ---- ---- ---- -------------- Area(Sgft) ---------- --------- North --------------- Commercial 1.13 1.0 1.0 None 35 West Commercial 1.13 1.0 1.0 None 27 West Commercial 1.13 1.0 1.0 None 0 East Commercial 1.13 1.0 1.0 None 0 Total Glass Area in Zone 1 = 62 Total Glass Area = 62 402------- WALLS --ZONE 1------------------------------------------------ --- Elevation --------- Type -------------------------------- U Insul R ----- ------- Gross(Sgft) ----------- East Frame Wall + 3" InS. 0.081 0.0 96 West Frame Wall + 3" InS. 0.081 0.0 96 North Frame Wall + 311 InS. 0.081 0.0 448 South Frame Wall + 3" InS. 0.081 0.0 448 Total Wall Area in Zone 1 =_ 1088 Total Gross Wall Area = 1088 403------- DOORS --ZONE 1------------------------------------------------ --- Elevation Type U ----- Area(Sgft) ---------- --------- East ------------------------------------------ 1-3/4 Steel Door -Solid Urethane foam co 0.40 40 Total Door Area in Zone 1 = 40 Total Door Area = 40 404.------ROOFS--ZONE 1------------------------------------------------ --- Type Color U Insul R ------ ----- ------- Area(Sgft) ---------- ------------------------------------ STD. TRUSS' Light .0526 19 672 Total Roof Area in Zone 1 = 672 Total Roof Area = 672 405------- FLOORS -ZONE 1------------------------------------------------ --- Type Insul R ------- Area(Sgft) ---------- ------------------------------------------------ Floor over Unconditioned Space/Insulated 11 672 Total Floor Area in Zone 1 = 672 Total Floor Area = 672 406.------INFILTRATION -------------------------------------------------- --- CHECK Criteria in 406.1.ABCD have been met. IInfiltration MECHANICAL SYSTEMS CHECK HVAC load sizing has been performed. (407.1.ABCD) 407.------COOLING SYSTEMS----------------------------------------------- --- Type No Efficiency IPLV ------------- ------------------- Tons ---------------------------- 1. Single Package 1 10.0 0.0 3.00 408.------HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr 1. Electric Resistance 2 1.0 35000 409.------VENTILATION --------------------------------------------------- --- CHECK Ventilation Criteria in 409.1.ABCD have been met. I 410------ AIR DISTRIBUTION SYSTEM----------------------------------------- --- CH.E,CK ------------------------------------------------------------ ---- --- Duct sizing and design have been performed. (410.1.ABCD) AHU Type Duct Location R-value ---------------------------------------------------------------- 1. Packaged Constant Volume Ventilated 6 CHECK ---------------------------------------------------------- --- --- Testing and balancing will be performed. (410.1.ABCD) 411.-----PUMPS AND PIPING -ZONE ----------------------------------------- --- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411------ PUMPS AND PIPING -ZONE 1--------------------------------------- --- Type R-value/in ---------- Diameter -------- Thickness --------- ------------------------ 1. Non -Circulating w/o Heat 3.63 0.75 1.0 412------ WATER HEATING SYSTEMS -ZONE 1----------------------.------------ --- Type Efficiency StandbyLoss InputRate Gallons 1. <=12 kW 1.5 0.0 3.5 6 ELECTRICAL SYSTEMS CHECK 413------ ELECTRICAL POWER DISTRIBUTION---------------------------- ----- --- Metering criteria in 413.1.ABCD have been met. ----- --- Motor efficiencies in 414.1.ABCD have been met. 415------ LIGHTING SYSTEMS -ZONE 1--------------------------------------- --- Space Type No Control Type 1 No Control Type 2 No Watts Area(Sgft) Reading, T 1 On/Off 2 None 00 526 636 Toilet and 1 On/Off 2 None 00 60 36 Total Watts for Zone 1 = 586 Total Area for Zone 1 = 672 Total Watts = 586 Total Area = 672 CHECK Lighting criteria in 415.1.ABCD have been met. 16. Operation/maintenance manual will be provided to owner.(102.1) ---------------------------------------------------------------------------- SANFOR.D FIRE.DEPARTMENT FIRE PREVENTION DIVISION IL 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 302-2520- Pager (407) 918-0395 Plans Review Sheet Date: November 24, 2004 Business Address: W..1201 W. P. Ball Blvd Occ. Ch. New Mercantile Business Name: Target Store #1966 Ph. ( ) Contractor: Bob Sanders Electric Ph. (407) 467-0055 Fax. (407)324-8028 Reviewed [ ] Reviewed with comment [X ] Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Fire alarm instillation inside a new Mercantile Occupancy 1.1 Application — New installation of one (1) pull stations, multiple smoke detectors, and multiple duct detectors; multiple horn/strobes through out store • Knox box required (see application attached) • 75 disables of sound shall be available inside structure (per N.FPA. #72) • Monitoring phone lines shall be 31jx type • Battery calculations verified • Final function test required by Sanford fire department • Additional Horn Strobes maybe required if visual, and (or) decibel sound is not per N.F.PA. #72 • Fire Suppression system shall be tied into the main fire alarm system as full activation • 48 hour notice required on inspections • Place fire alarm system off test and have live for finial 1