Loading...
HomeMy WebLinkAbout1151 Rinehart Rd 05-813 Fire mainPermit # : C) — R)k Job Address - T CITY OF SANFORD PERMIT APPLICATION Date: Z - g - 0 Description of Work:-r—Al 51 1L F/PF M 0,, A A 6 DG / Historic District: Zoning: Value of Work: $_ 60 5 Sd• O d Permit Type: Building Mechanical: Residential Non -Residential — Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets Occupancy Type: Residential Commercial Construction Type: # of Stories: Parcel#: iJP Owners Name & Address: Contractor Nan e & Phone & Fax: Bonding Company: Address: Mortgage Lender: _ Address: Architect/Engineer: Address: Alarm Pool Addition/Alteration Change ofS—erviceTemporaryPole Replacement New (Duct Layout & Energy Calc. Required) of Water & Sewer Lines # of Gas Lines Plumbing Repair — Residential or Commercial Industrial Total Square Footage: 600 of Dwelling Units: Flood Zone: (FEMA form required for other than X) Attach Proof of Owt ership & Phone: — i 7 late License Number: da 1 r T`. Phone: r Fax: 7000©O/ a©0 / X07 ;W -3 3 - Application is hereby made to obtain a permitto do th&work i l as i di ted. I rtify that no'work or installation has commenced prior to the issuance of a permit and that all work will be perfAwd to me t ds o r u in consinretion:•in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK; ME L S, RNACES, BPILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements4 FloridaLien Law, FS 713. Z Signature of Owner/Agent Date Sig ature of Contractor/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is _ Produced ID Personally Known to Me or APPLICATION APPROVED BY: Bld :1) 1 12- ZO 0 t Zoning: Initial & Date) Special Conditions: VI 1046167- S- C 12A1r/ Print Contractor/Agent's- ame 12-,9 ` iinaturofNqttoofFVIAM. JOHNSONDate MY COMMISSION # DD 285622 EXPIRES: March 23, 2008 0 Contractor/AgS visto° e P f i't1 61at brticat roduced ID -55-7-(00.37 Z U Utilities:J' FD: Initial & Date) (Initial /&: Datey Initial & Date) o t k) 2^ , J c 3'-6" MIN. AMES 3000SS DOUBLE DETECTOR BACKFLOW PREVENTER FJ f i PIPE STAND FINISHED ( TYPICAL) GRADE PROVIDE ELECT. SUPERVISED TAMPER SWITCH (TYPICAL) COORDINATE WIRING BY ELECTRICAL CONTRACTOR 2-#4 CONTINUOUS TYPICAL) GALVANIZED ANCHOR FLANGE (TYPICAL). BACKFLOW PREVENTER DETAIL 1\1 TQ DOUBLE DETECTOR DETNL PENDENT DEFLECTOR RETURN BEND DETAIL NTS RINEHART ROAD ESCUTCHEON DROP NIPPLE LENGTH VARIES) REDUCING COUPLING CEILING SPRINKLER PENDENT DEFLECTOR PENDENT SPR NKEER DETAIL NTS d . 0 L y 1 L .i. Z7 .' 1Ca sa% Y• — Crain [-ire Sp rinklers Corp. 5518 Force Four Pkwy., Orlando, Florida 32839 Phone (407) 438-4767 * Fax (407) 438-4794 Toll Free (800) 370-8843 * E—Mail CFSC@Bellsouth.net Florida State Certification 099405000192 Florida State Certification 62267000012001 General Notes TRAPEZE HANGER DETAL NTS EXTERIOR WALL FINISHED GRADE MIPd. 5'-0" — POINT OF TRANSITION FROM 4" STAINLESS STEEL IN -BUILDING RISER TO AWWA C900 PVC. FOR CONTINUATION REFER TO FLOOR PLANS. M CLAMP L 7 T IIY ULVV 1\I.J LI\ EL. 97'-0" BASE OF R SER DETAIL NTS TOP BEAM CLAMP ALL THREAD ROD PIPE HANGER RING TOP BEAM CLAMP HANGER DETAIL NTS AFF R EL. 100'-0" REDUCING COUPLING 1" SPRIG LENGTH VARIES) T UPRIGHT SPRINKLER DETAIL NTS TO SUPPLY — TO YARD MTD. FIRE DEPT CONNECTION FIRE SPRINKLER SYSTEM RISER DETAIL NTS TYPICAL LAYOUT FOR GENERAL LAYOUT REFERENCE ONLY - NOT PART OF UNDERGROUND SUBMISSION A ENDF SER DETA L2 ' R SE= DETA L 4" DR 14 "BLUE ,BRUTE" PVC PIPING STAR "PVC STARGR P" M.J. WEDGE ACTON RESTRAINT NTS REMOVE PLUG AND CONNECT TO LUG PIPE RESTRA N 1 EXIST. 8" G.V. EXIST. 8 WM 4" G. V. 8"x8"x4" TEE --- - I - TO METER BANK 1. All Pipe Locations are to be Field Measured Prior to Fabrication and Installation by Sprinkler Contractor. z. All Dimensions Shown are Center To Center 3. High Temperature Heads are to be Field Located Where Required. 4. All Pipes and Hangers are to be Installed per NFPA #13. 5. Hangers are to be U.L. Listed and F.M, Approved. C:\Documents and Settings\MIKE\My Documents\2004_drawings\Rhinehart Retail\FINAL.dwg, 12/6/2004 5:50:43 PM, HP DesignJet 650C(C2859B) by HP DCDA ASSEMBLY GALVANIZED SCHEDULE 40 PIPE USED HERE W, i 12" MIN. TOP OF INLET CONN. SEE SPECIFICATIONS FOR LABEL NOMENCLATURE. FIRE DEPT. CONN., 2 -WAY SHOWN; SEE SPECIFICATIONS FOR EXACT TYPE TO BE INSTALLED. IDENTIFICATION BASE PLATE. SEE SPECIFICATIONS FOR LABEL NOMENCLATURE. FINISHED GRADE 1 4" WAFER CHECK VALVE WITH BALL DRIP VALVE; PROVIDE GRAVEL BASE FOR DRAINAGE FREE STANDING EDC DETAIL NTS NOTE: 1, MOUNTING HEIGHT SHALL COMPLY WITH AUTHORITIES HAVING JURISDICTION. GENERAL NOTES: 1, TOTAL AREA PROTECTED EACH SYSTEM: AS NOTED ON PLANS, 2. 1" TO 1q' PIPE: SCH.40 STEEL, THREADED FITTINGS. 3. 1T TO 6" PIPE: SCH.10 STEEL, GROOVED FITTINGS. 4. ALL SCH.10 PIPING 1ji" AND UP TO HAVE SHOP WELDED OUTLETS. 5. PLANS HAVE BEEN CONFORMED TO NFPA 13 (2002 ed) sec.14.1.3. 6. BRANCH PIPING ELEVATIONS ARE GENERALLY 7" BELOW BOTTOM OF STEEL JOISTS, WITH 1" SPRIGS AS NECESSARY TO LOCATE UPRIGHT SPRINKLER DEFLECTORS WITHIN 10" OF THE CEILING. 7. MAIN PIPING ELEVATIONS ARE GENERALLY 14" BELOW BOTTOM OF STEEL JOISTS. NOTE: ALL ALARM SWITCHES INDICATED ON THESE PLANS (TAMPER SWITCHES, FLOW SWITCHES, ETC.) SHALL BE MONITORED PER AHJ CODES. FIRE ALARM DRAWINGS COORDINATING INSTALLATION OF THESE COMPONENTS BY OTHERS; WIRING AND CONDUIT BY OTHERS. DESIGN CRITERIA: 1) ORDINARY HAZARD GROUP I : 0.15 GPM PER SQ. FT. OVER 1500 SQ. FT., 130 SQ. FT. MAXIMUM HEAD SPACING, 250 GPM HOSE ALLOWANCE. OCCUPANCIES HAVING CONDITIONS SIMILAR TO MERCHANTILE OR RESTAURANT SERVICE, MECHANICAL OR ELECTRICAL ROOMS. CODES REFERENCED IN THE DESIGN OF THIS FIRE SPRINKLER SYSTEM: UNDERGROUND: NFPA 24 (2002 ed.); ABOVE GROUND: NFPA 13 (2002 ed.); NFPA 14 (2000 ed.) ABBREVIATIONS AFF Symbols Symbol Description O Hydraulic Reference Points Eis et] Elev. Below Top of Steel s-61 Elev. Above Finished Floor TOS 20-0) Elev. of Top of Steel TYP Ceiling Height L Denotes Hanger Location 0 Rise up or down GALVANIZED SCHEDULE 40 PIPE USED HERE W, i 12" MIN. TOP OF INLET CONN. SEE SPECIFICATIONS FOR LABEL NOMENCLATURE. FIRE DEPT. CONN., 2 -WAY SHOWN; SEE SPECIFICATIONS FOR EXACT TYPE TO BE INSTALLED. IDENTIFICATION BASE PLATE. SEE SPECIFICATIONS FOR LABEL NOMENCLATURE. FINISHED GRADE 1 4" WAFER CHECK VALVE WITH BALL DRIP VALVE; PROVIDE GRAVEL BASE FOR DRAINAGE FREE STANDING EDC DETAIL NTS NOTE: 1, MOUNTING HEIGHT SHALL COMPLY WITH AUTHORITIES HAVING JURISDICTION. GENERAL NOTES: 1, TOTAL AREA PROTECTED EACH SYSTEM: AS NOTED ON PLANS, 2. 1" TO 1q' PIPE: SCH.40 STEEL, THREADED FITTINGS. 3. 1T TO 6" PIPE: SCH.10 STEEL, GROOVED FITTINGS. 4. ALL SCH.10 PIPING 1ji" AND UP TO HAVE SHOP WELDED OUTLETS. 5. PLANS HAVE BEEN CONFORMED TO NFPA 13 (2002 ed) sec.14.1.3. 6. BRANCH PIPING ELEVATIONS ARE GENERALLY 7" BELOW BOTTOM OF STEEL JOISTS, WITH 1" SPRIGS AS NECESSARY TO LOCATE UPRIGHT SPRINKLER DEFLECTORS WITHIN 10" OF THE CEILING. 7. MAIN PIPING ELEVATIONS ARE GENERALLY 14" BELOW BOTTOM OF STEEL JOISTS. NOTE: ALL ALARM SWITCHES INDICATED ON THESE PLANS (TAMPER SWITCHES, FLOW SWITCHES, ETC.) SHALL BE MONITORED PER AHJ CODES. FIRE ALARM DRAWINGS COORDINATING INSTALLATION OF THESE COMPONENTS BY OTHERS; WIRING AND CONDUIT BY OTHERS. DESIGN CRITERIA: 1) ORDINARY HAZARD GROUP I : 0.15 GPM PER SQ. FT. OVER 1500 SQ. FT., 130 SQ. FT. MAXIMUM HEAD SPACING, 250 GPM HOSE ALLOWANCE. OCCUPANCIES HAVING CONDITIONS SIMILAR TO MERCHANTILE OR RESTAURANT SERVICE, MECHANICAL OR ELECTRICAL ROOMS. CODES REFERENCED IN THE DESIGN OF THIS FIRE SPRINKLER SYSTEM: UNDERGROUND: NFPA 24 (2002 ed.); ABOVE GROUND: NFPA 13 (2002 ed.); NFPA 14 (2000 ed.) ABBREVIATIONS AFF ABOVE FINISHED FLOOR DWG DRAWING CONT CONTINUED LINO UNLESS NOTED OTHERWISE N/S NO AUTOMATIC SPRINKLER Revisions: REQUIRED IN THIS SPACE TYP TYPICAL FDC FIRE DEPARTMENT CONNECTION PIV POST INDICATING VALVE POS POINT OF SERVICE HYD FIRE HYDRANT F.C. FLUSHING CONNECTION DN DROP NIPPLE RN RISER NIPPLE CFSC CRAIN FIRE SPRINKLERS CORP. CENTER LINE PIPING LEGEND Number of Sprinklers Drawing Fire Protection Details, Underground Title Job: DIKEOU RETAIL 1101 Rhinehart Rd Sanford, FL Total This Sheet o Total This Job 513 Symbol Description Contract No. Revisions: Date: Drawn By Mike Alicea Scale NO SCALE Contractor: CPH ENGINEERS 500 W. FULTON ST SANFORD, FL 32772 W WDate12/01/04 Approval By MC/Hc