Loading...
HomeMy WebLinkAbout105 E End Ct 07-1180 PoolPermit # Job Address: Description of Work: P�U L w 1 .` 'total Square Footage Historic District: Zoning: ( vlllue of Work: Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool CITY OF S ANFORD PERINfIT APPLICATION eo IQte: 2— I— Olt- �OUJ Electrical: New Service — # of AMPS Mechanical; Residential Non -Residential — Plumbing/ New Commercial: # of Fixtures Plumbing/New Residential: # of Water Closets — Occupancy Type: Residential Commercial Addition/Alteration Change of Service Temporary Pole _ Replacement New (Duct Layout & Energy Calc. Required) # of Water & Sewer Lines It of Gas Lines Industrial Plumbing Repair — Residential or Commercial Construction Type: �J # of Stories: It of Dwelling Units; Flood Flood Zone: (FEMA form required !) Owners Name & Address: Cl �/5 �/t/L�G� CL'/� C Phone:) Contractor Name & Address:�t ! �r,/�b� N '3G( /���1 L 3 'T 7 D 7 State License Number: _[`K'4�y, `fit l 'lot Z1yrt �6C�o act Person: /�t�1 ✓J 1 (�Y �J�' Phone: �7 �� 7 Phone & Fax: _tu Bonding Company: Address: Mortgage Lender: _ Address: Architect/Engineer: Phonc: 11 'Z Address: I D.,C) rL Fax: 04 & Application is liereby made to obtain a permit to do the work and installations as indicated. 1 certify that n �vork or installation has commenced prior to the issuance of a permit and that all work will be perronned to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit ]trust be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, IIEA'fERS,'I'ANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that till work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE'I'0 RECORD A NOTICE OF COMMENCEMENT MAY RESULTIN YOUK PAYING TWICE FOR IMPROVEMEN'I'S TO YOUR PROPERTY. IF YOU INTEND To OBTAIN FINANCING, CONSUL; I' WIT11 YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additioial permits required front other governmental entities such as wider orurrgenicut districts, state agencies, or federal agencies. Acceptance of f em it is verificatioII notify the owner I property n a w] Sigi of Owner/A�ent Date t -e Print caner Agent's N une ^ Signature of NotarylStatc of Hurida 'Da te(,/ waY �v� Nola Puitli, "ate of Florida � `r; Rua J Purcell is M Commission DD408593 wud�/�geiiits XUllis:i4Ah2_t#.1_ib_w_n to Me o Produced ID APPROVALS: ZON1 ' c G d flL: FD USpecial Conditions: Rcv 03/2006 of the require] 'nts of Flori Li a FS V . 2t�'7 S 6rt ]re oft f 'onln or/Agent Date Prim/t CContractor/Agent s Name ry / '; — 9yv ignature of Note -Stale of Florida Dale �,p:m Pv,, �Plotaty Public State of Florida Reed J Purcell t? My Commission D0408593 Con zTclo Agenlia4' Me or, i _ Produccd� lD jy�'�"""�/T, �`d%.IP ENG: BLDG:_ Windows and doors that open into the swimming pool/spas area without a fence barrier to prevent direct access shall be protected in accordance with FRC R 4101.17.1.9 Equipotential Bondinq grid Shall be provided for the first 3-feet of the perimeter of paved surfaces of swimming pools and spas. 2005 NEC Article 680.26(C). SCREEN ENCLOUSURE 48" HIGH CHILD SAFETY FENCE 1 PDOLDAsS1GiV.iVAs'T The residential swimming pool barrier and or its compliant safety components shall be in pace prior to filling of the pool. FRC R4101.17 ' Structural plan review is limited to a general survey for code compliance. No review is implied nor was taken to ve rify structural adequacy N 89" 56' 18" E 6U' i �T-6" UTI ITY EASEMENT- `I I Fi I SCREEN ENCLOUSURE DOORS TO BE SELF CLOSING AND SELF LATCHING 1 I It. 4 in. r� r POOL EQUIPMENT ELECTRIC METER Code violations found during inspection are required to be corrected. Plan/permit issuance does not grant approval of a code violation. 2004 FBC109.1 NOTES: IF WATER SOURCE IS A PRIVATE WELL- PRE -FILTER WATER TO FILL POOL ALL METALLIC ITEMS WITHIN 5'-0" OF WATER's EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (u.l. listed) FROM POOL STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' MIN. AND 20' MAX, FROM POOL IF ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR PROPERTY GATES TO BE SELF CLOSING AND SELF LATCHING PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP @ 48 TIMES DIAMETER ESTABLISH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENCY, ALLOW MIN. 10' HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO POOL WATER. DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE POSITIVELY SLOPED FOR DRAINAGE PROVIDE WEEP HOLES AND DEWATERING PUMPS AND ANY OTHER METHODS NECESSARY TO PREVENT THE POSSIBILITY OF THE POOL FLOATING DUE TO HYDROSTATIC UPLIFT PRESSURE WHEN THE POOL IS EMPTY. BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TO ASSURE THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO THAT NO VOIDS EXIST PROVIDING A FIRM BEARING FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) THIS IS NOT A DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BREAKER LOCATE POOL RETURNS DOWN 18" MIN. BELOW THE POOL BEAM POOLDESIGNAET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: SrRUC'rURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) 'THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNi TE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A.T.S.M..15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S,F,•PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. rl Or KAREN M.fRS 1000 E ATLA TIC B VD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 POOL AREA PLAN TITLE TOL.ER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scab: 1 in = 20ft. Oin. DATE 2/2/2007 PAGE 1 OF 4 WALKING ROOM— I 8" SCREEN BEAM i � --------------------------- FIRE P11'� i 8 ft. 7 in. I +18" I I I I I I � I I i z I I � m I , Q i . I POOLDE,SIGiV. NL1' I, , I t I I CA 1 l t I \ / I ` ' I CV �� PLANTER / t PLANTER I all ti , tI 2 J R 3' 0,. ; t -- - +18 i gin 3' DEEP % �n R 5'-6,. —� 2 . 2 in. Q I N I \- 5'-6" DEEP I U. Y �ON �O `Q lb R 9'-0" \ V' / 20" 5 ft. 5 in. , 1' 13 ft. 10 in. 91. 7 ft. 8 --- r 7 t I ' WALKIN ROOM 8" SCREE V BEAM I I ' t I 1 / \ / I RESIDENCE 1 IIEVIEWED PLANS CITY I I I z co C9 I m I POOLDESIGN.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@swirnmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B,C. 2)'THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) -THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNI7E/SHO"TCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A,'T,S.M.•15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING To COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. KARE AKERS 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 LAYOUT PLAN TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scale: 1/4" = V-0" DATE 2/2/2007 PAGE 2 OF 4 .e- NOTE: ALL EMBEDDED ITEMS TO BE INSTALLED PRIOR TO GUNITE: 1. MAINDRAINS AND LINES 2. SKIMMER 3. LIGHT NICHES 4. RETURN LINES 5. CLEANING LINE , 6. SPA PLUMBING IF INSTALLED INSIDE WALL r 7. BOND WIRE 6. WATER FEATURE LINES AND ANY OTHER THROUGH WALL LINES AND FIXTURES I POOL i EQUIPMENT I I i I 2" RETURN LINES 2" WATERFALL LINE POOL LIGHT 1-1/2" VENT LINE 2" MAIN DRAIN LINE 2" UNDERPRESSURE LINE 2" SKIMMER LINE 2" CLEANER LINE POOLDESIGNAET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 Info@ swi rnm ingpool plan. corn CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1600 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM 'TO A.C.I 318.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 6) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO kns.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B,C . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. r n //ff �� 4 C/�e_ ve, ,p� KAREwlK S 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 P.E. 59993 PLUMBING PLAN TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 Scale; 1 /4" = 11-011 DATE 2/2/2007 PAGE 3 OF 4 POOL ELECTRICAL DETAIL TO SERVICE - G.F.I. OUTLET I t r I I I I SWITCHES—p 'i I I N 3 #12s IN 1/2" CONDUIT \ I JUNCTION BOX locate b" min, abov water line. 111111 ALL ELECTRICAL TO COMPLY TO N.E.C, ALL EQUIPMENT INSTALLED PER MANUFACTURER SPECIFICATIONS �I —I 3 #12s IN 1/2" CONDUIT 12v TRANSFORMER 1-11 PER 2005 NEC (680.26C "EQUIPOTENTIAL BONDING GRIP"): 3' WIDE GRID OF SOLID COPPPER 48 AWG WIRE BURIED IN SAND, GRID SHALL BE 12" CIC WITH MAX SIZE SQUARE OF 16". COPPER CONDUCTORS SHALL BE •TERMINATED AT EACH CROSSING BY EXOTHERMIC WELDING, LISTED PRESSURE CONNECTORS, LISTED CLAMPS OR OTHER LISTED MEANS. SCREEN FOOTER DECK DETAIL. N " " 36X 8STEM WALL �.. I m.-11111111=1111111�1111111= IIIIII� 1111= IIIIII'�` r COMPACTED FILL INrI �G 1, I 18" X 12" FOOTER W/ 2 #5 CONT. �• - - I #8 AWG BARE SOLID COPPER BONDING JUMPER SHALL BE / INSTALLED IN AT LEAST FOUR (4) LOCATIONS EQUALLY I SPACED AROUND PERIMETER OF THE POOL OR SPA. t` '-----------------------___---- ----- #t3 AWG INSULATED COPPERWIRE EPDXY EPDXY COATED (IN LIGHTCORD CONDUIT) (IN CONDUIT) STRUCTURAL DETAIL INTERLOCKING BRICK PAVERS �(-- BULLNOSE BRICK COPING SLOPE DECK 118" PER FOOT FROM POOL. CONT 18" MIN. FROM TOP OF LIGHT TO WATERLINE --_._,_,___COAT BOND CONNECTION W/ APPROVED POTTING COMPOUND \300 WATT 12v REMOVABLE UNDERWATER UL LIGHT ANTI -ENTRAPMENT POOL DETAIL ' VENT LINE TO BE tft MIN. ABOVE POOL WATER ................................ 11 drg max Smooth Troweled ; E Plaster Interior 8" AntiVortex Main Finish I ! °.' LLL Drain Grate Shall Be Secured In Place 6" Thick Walls LU So That Tools Are z �' Required For Removal z ANTI- �ENTRAPMENT PER PLAN MAIN DRAINS TO HAVE ANSI I ASME A112.19.$M ANTI VORTEX �IME CLOCK �6" WALLS ° MAIN DRAIN LINE COVER � � o 6'220v 6" FLOOR PEBBLE TECOR #8 AWG INSULATED COPPER POOL STEEL OVERLAP �-�MOND BRITE o WIRE GROUND TO POOL @48 TIMES DIAMETER #3 STEEL@ 12' 0/ m PLASTER FINISH Gravel Sump° STEEL HORIZONTAL & 0 ° ° 0 1.5 HP VERTICAL PROVIDE 3" MIN COVER TO DIRT ° AND 2" MIN. COVER TO WATER POOL PUMP ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #6 SOLID /NSULA'TED WIRE (Ud. //sled) FROM POOL 8 AM P STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITI4 BRASS GROUND LUGS......G.F.1. OUTLET 10' MIN. AND 20' MAX. FROM POOL FILTER DETAIL 1,5 HP POOLPUMP FILTER B AMP 75 GPM 325 S,F,- U, Uam� 1.5 Zqo ¢Wo g �z i N ❑LU 3 WAY W VALVE �) S Z (V m W N o ;o 1y 3 WAY m z VALVE %0 N 0' POOL N MAIN DRAINS D mmi , 71 A ;�u z r— r— r G rn A.- JUNCTION BOX 5' MINIMUM FROM MINIMUM 11 DEGREES MAX. ANGLE FROM PLUMB \ 4'-0" POOLDESIGN.NGT 27'.0" 8" #3s 16" O/C 36" X 8" STEM WALL, STEEL REINFORCED AND FILLED I CONCRETEBLOCK Ij, + CV ���PPP _ 18" X 12" FOOTER =n — I W/ 2 #5 CONT. STEM WALL DETAIL 6" CERAMIC TILE 0 42" R 0 12„ 12 ! 7' m SLOPE OF POOL BOTTOM NOT TO EXCEED V IN 7' �Z ---- 8" ANTIVORTEX MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS ARE REQUIRED FOR REMOVAL HYDROSTATIC VALVE WITH WELLPOINT GRAVEL SUMP 3'-0" SHEAR DESCENT WATER FAIL POOL MAIN DRAIN ° ° ° Threaded Plug 0 0 ° -VENT IS nESIeNEo r0 EVACUATE SUCTION IN 3 SEC. OR LESS PER 424 -Tt115 SAFETY VACUUM RELIEF SYSTEM IS A NON- DETAIL POOL MAIN DRAINS TO BE o Hydrostatic ValVe ° W/ WellPoint o ° o MECHANICAL VENT SYSTEM THAT WILL LIMIT THE AN TRSMISSION OF SUCTION AT THE OUTLET TO A MAX. OF 4.5"OF MERCURY INSTALLED V APART PUMPING FLOW RATES 60 TDH VENT PIPE SIZE MAX LENGTH HP FLOW RATE 3/4 hp = 55 pm -112' 2g LF 1.0 hp = 7a gpm 1-1/2" 40 LF 1.5 hp = 90 m 1-1/2" 49 LF 2.0 hp = 95 qpni 1.1/2" 61 LF 2.5.hp = 115 cgprn 1.1/2" 62 LF 3.0 h = 150 gpm 1.1/2" 76 LF BASED UPON STA-RITE MAX-E-PRO SELF PRIMING PUMP w r. WP dF P0-0—L dEAV c 1/4" TAP CON BOLTS 4" THICK CONCRETE SLAE 1/4" TAP CON BOLTS PIPE PRESSURE FLOWS CT 0 FLOW SIZE CAPACITY (10FPS) CAPACITY (SFPS) 1.5" 60 gpm 49 gpm 2.0" 10o ppm 80 ppm 2.5" 150 gprn t10 gpm 3.0" 220 gpin 180 qpm r —1 L 1 CAPTILE EDGE OF CONTRASTING COLOR SWIMOUT DETAIL EQUIPMENT ANCHORAGE DETAIL POOL SPECIFICATIONS LENGTH 27'-0" WIDTH 14'-0' MIN. DEPTH 3'-0" MAX. DEPTH AREA 300 Sq. Ft. PERIMETER 72 Ft. GALLONS 9,300 TURNOVER RATE 1.9 HOURS INLETS 3 LIGHT(S) 300 W 12V PUMP 1.5 HP FILTER CARTRIDGE 325 S.F.- SKIMMERS 1 I MAIN DRAINS 2 POOLDESION.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: STRUCTURAL 1) PLANS DESIGNED PER 2004 F.B.C. 2) -THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSR 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH, IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 4) ALL CONCRETE SHALL CONFORM TO A.C.I 316.02, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEAL CONFORMING TO A.T,S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I, STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V,C, MIN. POOL PIPING TO COMPLY WITH F.B,C . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. /l 07 1000 E ATLANTIC BLVD SUITE 100 POMPANO BEACH, FL 33060 I.E. 59993 DETAILS TITLE TOLER RESIDENCE DESCRIPTION 105 E END COURT SANFORD, FL 32771 DATE 2/4/2007 PAGE 4 OF 4