Loading...
HomeMy WebLinkAbout1133 Rinehart Rd 07-1024 Horn strobescrate ; o-A — \ C3 ea`` CITY OF SANFORD PERMIT APPLICATION Permit # : Job Address: Description of Work: Historic District: Zoning: Date: Value of Work: $ 7 10 Permit Type: Building Electrical Mechanical Pluming Fire Sprinkler/Alarm rl- Pool Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: i/ of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential or Cortunercial Occupancy Type: Residential Commercial Industrial Total Square Footage: Construction Type: # of Stories: # of Dwelling Units. Flood "Lone: (FEMA form required for other than X) Parcel #: (Attach Proof of Ownership & Legal Description) Owners Name & Address: Contractor Name & Address:,,C Phone & Fax:1AQn "�rw Bonding Company: Address: Mortgage Leader: Address: Phone: '-S'D�7-0 State License Number: Contact Person:, \ p V ,I 1 SCJ � ri2 I l Phon0A 01 Fn &S -"'cox-- '(- I Q W Architeeffugmeer: Phone: Address: Fax: _ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER- YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management 'stricts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requ.r mmee' is f Flot'C a L� w, FF'' 713 / 1 Q/ �. Signature of Owner/Agent Date Signature of CorUractor/Arent Date Print Owner/Agent's Name nt Con for/Agent's Name 0-1 Signature of Notary -State of Florida Date Signature of No • -State of Florida at'q Vicky Spinella * My Commission D0306446 vt/ t0 na` Expires April07 2008 Owner/Agent is _ Personally Known to Me or Contractor/Agent is I_ Personally Known to Me or Produced ID Produced ID APPLICATION APPROVED BY: Bldg. Zoning: Utilities: FD: 1� (Initia &Date) (Initial & Date) (Initial & Date) (Initial & Date) Special Conditions: C� N EXISTING PANEL : I I I� ................................................. �1 N-36 I i I N-30 N 34 N3111, 33 N-28 N-32 I � I I I / i ......... ........ \ -33 I J -33 M-7 M-7(f J ..........OIN......................__' WS ..... 7 N-35 j 1 NOTE 3. (TYPICAL) _N-36 -35 M-40 TV �rN-1 Iv M-40 TV NOTE 4. ,_....' . CONVEYOR OVEN N-14(16) NEMA 1 30 3P FUSED 20 240V (3)#12, (1)#12 GND IN 3/4" EMT C. EQUIPMENT SCHEDULE I.D. NO. DESCRIPTION VOLTAGE LOAD CONNECTION WIRE AND CONDUIT CASH REGISTER 120V 15A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. E3 SWING DOOR REFRIGERATOR REACH -IN 120V 7.2A NEMA 5-15P (2)#12, (1)#12 GND IN 3/4" C. Es UNDER COUNTER WORK TOP REFIGERATOR 120V 3.9A NEMA 5-15P (2)#12, (1)#12 GND IN 3/4" C. L7 PIZZA PREP TABLE 60" 120V 7.9A NEMA 5-15P (2)#12, (1)#12 GND IN 3/4" C. E8 > PIZZA PREP TABLE 67" 120V 8.6A NEMA 5-15P (2)#12, (1)#12 GND IN 3/4" C- C PIZZA CONVEYOR OVEN, DOUBLE STACK 208V 10A DISC SW. (3)#12, (1)#12 GND IN 3/4" C. E11 . EXHAUST HOOD W/INT. FIRE SUPPRESSION 120V 15A J-BOX (2)#12, (1)#12 GND IN 3/4" C. TEA BREWER 120V 29.6A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. E13 ` TEA BREWER 120V 29.6A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. Eta ' ICE MAKER SODA DISPENSER 120V 3.5A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. : E15 i ICE MAKER 120V 7.8A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. (E16n) COMMERCIAL MICROWAVE OVEN 120V 15A NEMA 5-15P (2)#12, (1)#12 GND IN 3/4" C. E17 % ELECTRIC WATER HEATER 208V 4.5KW DISC SW. (2)#10, (1)#12 GND IN 3/4" C. PIZZA HOT BAG SYSTEM 120V 9.4A NEMA 15R (2)#12, (1)#12 GND IN 3/4" C. Ezo ,, WALK-IN FREEZER EVAPORATOR 208V/1 P 13.2A DISC SW. (2)#12, (1)#10 GND IN 3/4" C. ( E2o WALK-IN FREEZER CU 208V/1 P 6.5A DISC SW. 2)#12, (1)#10 GND IN 3/4" C. E20 ; WALK-IN COOLER EVAPORATOR 208V/1 P 8.7A DISC SW. 2)#12, (1)#10 GND IN 3/4" C. ( E20`, WALK-IN COOLER CU 208V/1 P 2.2A DISC SW. 2)#12, (1)#10 GND IN 3/4" C. NOTES: 1. COORDINATE DEVICES TO BE MOUNTED IN MILLWORK WITH 5. PROVIDE SINGLE GANG JUNCTION BOXES FOR SIGN POWER TO BE ARCHITECTURAL DRAWINGS. CONTROLLED BY TIME SWITCH. PROVIDE (2)#12, (1)#12 GND IN 3/4" EMT C. COORDINATE INSTALLATION WITH ARCHITECTURAL DRAWINGS. 2. PROVIDE PLYWOOD TTB AND PAINT TO MATCH WALL FINISH. PROVIDE CONDUIT AS NECESSARY TO ROUTE TELEPHONE SERVICE TO SPACE FROM 6. PROVIDE (2)#12, (1)#12 GND IN 3/4" EMT C. FOR EACH CIRCUIT AND BUILDING CONNECTION POINT, MINIMUM OF (1) 2" EMT C. CONNECT TO EXHAUST HOOD ELECTRICAL TERMINAL CABINET. PROVIDE (2)#12, (1)#12 GND IN 3/4" EMT C. FROM EXHAUST HOOD ELECTRICAL 3. PROVIDE SINGLE GANG JUNCTION BOXES INSTALLED IN CHANNEL TERMINAL CABINET TO EXHAUST AND SUPPLY FANS LOCATED ON ROOF. ADJACENT TO TABLES WITH (2)#12, (1)#12 GND IN 3/4" EMT C. COORDINATE INSTALLATION WITH ARCHITECTURAL DRAWINGS. PROVIDE 7. PROVIDE CONNECTION OF WALK-IN FREEZER EVAPORATOR TO CONNECTION TO DUPLEX RECEPTACLE WITH FLEX CONDUIT. CONDENSING UNIT AS RECOMMENDED BY MANUFACTURER. PROVIDE DISCONNECT SWITCH AND INSTALLED AS SHOWN ON FREEZER SHOP 4. PROVIDE DUPLEX RECEPTACLE AND SINGLE GANG JUNCTION BOX FOR TV DRAWINGS. POWER AND SIGNAL. PROVIDE (2)#12, (1)#12 GND IN 3/4" EMT C. COORDINATE INSTALLATION WITH ARCHITECTURAL DRAWINGS. RTU CONNECTION SCHEDULE MARK VOLTAGE DISCONNECT STARTER PANEL FEEDER AND CONDUIT SIZE NOTES RTU-13A 208/3 NEMA313 60A, FU, 3P N/A M (3)#8, (1)#10GND IN 3/4"C. 1 RTU-14A 208/3 NEMA3R 60A, FU, 3P N/A N (3)#8, (1)#10GND IN 3/4"C. 1 UtNtNAL IVU I t: COORDINATE- WITH DIVISION 15 THE EXACT `.VOLTAGE AND RATING OF HVAC EQUIPMENT TO BE PROVIDED. NOTES: 1. PROVIDE DUAL ELEMENT FUSES SIZED AS RECOMMENDED BY EQUIPMENT MANIJFAC.TIJRFR. HOOD FAN CONNECTION SCHEDULE MARK VOLTAGE DISCONNECT STARTER PANEL FEEDER AND CONDUIT SIZE NOTES EF-1 208/3 NEMA3R 30A, FU, 3P NEMA 0 M (3)#10, (1)#12GND IN 3/4"C. 1,2 SF-1 208/3 NEMA3R 30A, FU, 3P NEMA 0 M (3)#10, (1)#12GND IN 3/4"C. 1,2 UtzNtKAL NU I t: COORDINATE WITH DIVISION 15 THE EXACT VOLTAGE AND RATING OF EQUIPMENT TO BE PROVIDED. NOTES: 1. PROVIDE DUAL ELEMENT FUSES SIZED AS RECOMMENDED BY EQUIPMENT MANUFACTURER. 2. PROVIDE STARTER AND CONNECT TO HOOD CONTROLS. SYM. QTY. Description of symbol HornStrobe Strobe only Manual pull station 2 2 Scope of work: Install 2 pull stations and 4 horn strobes as required by NPA 72 standard. All wiring to run back to facp in seperate unit. Programing and testing to be done by Comercial Systems Group as to maintain alarm warranty. wire used on job for nac circuit is 12/2 nplr and 16/4 nplr for intelligent alarm circuit. 1 POWER/SYSTEM _ Z E-110 S PLAN craig j. kosuta and associates, inc. 509 n. Virginia avenue winter park, florida 32789 p 407.647.7558 f 407.647.7339 10 license no. AAC002189 © copyright 2004 craig j. kosuta and associates, inc. all rights reserved worldwide. Project For: V J Z O Q N Q N I UJ W n Z L.L O U� L.L L.L Q Q0 W W w LL o O Z o z LL W 0 I A knox box type exterior security key box is required on this building. Call 407-302-2516 for information. NFPA 1 - section 18.2.2.1 OFFICE 1114,611 ili I I us-Alfza 4' 2' 0 4' SCALE:1/4"= V-0" Revisions: No.: Date- Description- J � Q I oo� �, 1 c 0�w�o co �-o�° A CNNLd N •L a� > \T� 0 O NmQ�Mrn � C > lal -.-� C� pi O I N C Nd� � w Ja�D0 OBI Q N~ rroJec-t uata: Project No.: 05-0035.01 Issue Date- 12/01 /06 Drawn By: JSR Checked By: NVA Approved By: NVA Sheet Contents: POWER/SYSTEMS PLAN