HomeMy WebLinkAbout1621 Rinehart Rd 07-1300 Fire Alarm01-Q3-z CITY OF SANFORD PERMIT APPLICATION �) Application #7-: � �� -j („/ �� r Submittal Date: 02/21/07 RECEIVED Job Address: A Rinehart Rd. Sanford, FL 32771 Value of Work: $ 2,252.00 Q � f 2007 Parcel ID: Zoning: Historic District: Description of Work: Add Fire Alarm Devices for Tennant Build Out Square Footage: ......................................................................................................................... Permit Type: Building ❑ Electrical ❑ Mechanical ❑ Plumbing ❑ Fire Sprinkler/Alartn Pool ❑ Sign ❑ Electrical: New Service - # of AMPS Addition/Alteration ❑ Change of Service ❑ --Temporary Pole ❑ Mechanical: Residential ❑ Non -Residential ❑ Replacement ❑ New ❑ (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair -Residential ❑ Commercial ❑ Occupancy Type: Residential ❑ Commercial ❑ Industrial ❑ Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood lone: (FEINIA form required) ........................................................................................................................ Property Owner: Steve & Liz Tibstra Contractor: L.V Solutions, Inc Address: 1621 Rinehart Rd. Sanford, FL 32771 Address: 106 Commerce Street Suite 103 Phone: Bonding Company: Address: Architect/Engineer: Address: E-rnail: Plan Review Contact Person: Lake Mary, FI, 32746 Phone: 771-2020 State License Number: EF0000043 Mortgage Lender: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of it permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. l understand that it separate Permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEA ERS, TANKS, and AIR CONDITIONERS, etc. a OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVI MENTS TO YOUR PROPERTY. IF'YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this courtly, and there may be additional permits required from other governmental entities such as water management districts, stale agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the rcquirenrcnts� ri�a ten I,' _ S 713. Signature of Owner/Agent Date Signature of Contractor/Agent Dale Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID APPROVALS: ZONING: Special Conditions; Rev 02/2007 Pri ttractor/A e rt's Name Signa ure lum—ot"i-y4tat, Contractor/Agent is __t_'5Pcrso Produccd10 UTIL: FD , �'" ... ENG: -'-v-d7. UARREN J, DARWENT — Nolary Public - State of Florlda 4Y Comrrl&t W trxPIMS Apr 16, 201, Cornmbsirm # DD 540674 Bonded By Natlonal Notary Assn. i BLDG:_ V 16) BACK FLOW PREVENTER TAMPER SWITCH, ONLY IF IT REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION MONITOR MODULE - (SUPERVISORY ALARM) SEE KEYED - ( NOTE 5 T DUCT SMOKE DETECTORS TYPICAL FOR RTU CI HOPI V RPTI (2) HOUSE PHONE LINES IN 3/4"C TO TELEPHONE BOARD AHU SHUTDOWN 120V PLUS GIRD. FROM HOUSE PANEL FIRE ALARM RISER DIAGO RAM N.T.S. WATER GONG (WEATHER PROOF): BY OTHERS PROVIDE 120V FROM HOUSE PANEL 120 V. CIRCUIT SEPERATE FROM FACP OPERATION MATRIX PULL STATIONS SMOKE DETECTOR DUCT DETECTOR BACROW TAMPER MAIN BUILDING FLOW BUILDING TAMPERS BUILDING FLOWS CD > O zD O Z� OC Z� =� �� ��� CD CD z c n cn � � COr;O M 70 -T1 > -T1 � rTl -q Z7 _ L/-) Z �"cn Dorr-r�-C a�- � DZ7 7�Q7 �� M �� �� �� �7 =F_ 1 c 7- c� y c7 c> B DEVICE DESIGNATION L1.1 Device number on Circuit Loop or Notification Circuit Number L-Addressable Device N-Notification Device 2 FIRE ALARM LEGEND1 SYMBOL MANUFACTURER DESCRIPTION MOUNTING INFORMATION FACv FARADAY MPC-6000 FIRE ALARM CONTROL PANEL TOP of PANEL AT B' AFF. FA__P1 FARADAY RDC-2 FIRE ALARM ANNUNCIATOR PANEL TOP OF PANEL AT 4f-9• A.F.F. © FARADAY 8700-S MANUAL STATION RING �00 w7 B" r]M FARADAY 8701 MINATURE MONITOR MODULE 4• SQUARE Box ® FARADAY 8710 SMOKE DETECTOR V OCTAGON eox L�3 BY OTHERS DUCT SMOKE DETECTOR PROVIDED AM INSTALLM BY MECHANICAL CONTRACTOR MONITORED BY FACP FOR ALARM AND TROUBLE BY OTHERS BY OTHERS SPRINKLER FLOW .� BY OTHERS BY OTHERS VALVE TAMPER Q KNOX LOCK BOX MINIMUM a FAT JUNCTION BOX END OF LINE RESISTOR EM FARADAY 2834E-14-24 HORN STROBE 4• SQUARE Box Ig FARADAY 270OB-14-24 STROBE IV SQUARE BOX s • AFF NOTE: "E" NEXT TO DEVICE DESIGNATES THAT DEVICE AS EXISTING WIRE LEGEND SYMBOL USE DESCRIPTION A INITIATING 2 CONDUCTOR 18 AWG FPLR C MONITOR 2 CONDUCTOR 18 AWG FPLR D PIV 2 CONDUCTOR 14 AWG WEATHERPROOF E REMOTE INDICATOR 2 CONDUCTOR 22 AWG FPLR MYMFNS r U.-J a ' 75cd Relocat N6-5 B B15cd L N6-3 A+B 75cd J i� L1-119 2A+2B �', OPERATIONS/ t.._,_ .. -- -- - CORRID MANAGER N6.2 iia c ® i _.._ 75cd ewe I CLOSET r C• 7 Z I CUSTOMER/ 28 SERVICE q+26 I X N 7 Jc< II I I INVENTORY0 LOEA] NL: ewE COPY 12 11-125 A+8A+8 ----a+B- Uj ..f -I - I i f4DfSfk q>WAY A+2B II c ( `1" RETAIL I VERI °I A+28 0 z I,k �-.— I J I IQ 10 I ACFS L1. N6-1 E 110cd L1-12 I I t U � (RTU`4Tl I rru`4T i C' II II C - I IA yg I — L1-118 A+2g A+2B A+ 0 N7-1 WP �o 75cd � I K C L1-10 F M L1-102 A L1-01A � M L1-103 � 2 3 AM L1-104 _ FACP 2—�o--t M L1�105 6 7 1 1 i 1 � 1 1 1 � 1 1 N2.2 75cd 2 1 N3-3 1 1 15cd i. 1 iA+B 1 +$ A+B ) d I 5cd 75c1 E UST -4i E2B I I� E I I I© I E Gli ]-J L�— E l 1 1 0®b 1 1 1 A+2B 1 .V 1... I A+21 A+21 1 1 1 _ 1 � � 1 1 E 2B A A0' 1 N31 2-1 5cd 1 L - 75cd 1 I Lt-112 1 1 1 1 1 1 c° 8 t; . t - L1-109 9 KEYED NOTES FIRE ALARM CONTROL PANEL INSTALLED EITHER FLUSH OR SEMI FLUSH. 0 PROVIDE DEDICATED 120 VAC CIRCUIT FOR FIRE ALARM CONTROL PANEL. O3 ONE (1) j" CONDUIT WITH CABLES FOR CONNECTION TO TELEPHONE LINES FOR MONITORING. Q PROVIDE AND INSTALL KNOX BOX WITH TAMPER SWITCH CONNECTED TO FIRE ALARM SYSTEM. © THESE UNITS ARE 1600 CFM AND DO NOT REQUIRE DUCT DETECTORS. ® DUCT DETECTORS ARE MONITORED BY ADDRESSABLE MONITOR MODULE. DETECTOR WILL REPORT TO FACP AS SUPERVISORY SIGNAL. TAMPER SWITCH FOR BACKFLOW PREVENTER. COORDINATE WITH ARCHITECT FOR SITE LOCATION PRIOR TO ROUGH IN. GENERAL NOTES 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL ADOPTED CODES 2. RACEWAY, POWER AND GROUNDING REQUIREMENTS SHALL COMPLY WITH APPLICABLE SECTIONS OF DEVISION 16. 3. MINIMUM RACEWAY SIZE SHALL BE J". 4. PROVIDE REMOTE INDICATION OF TROUBLES AND ALARM OF ALL DUCT SMOKE DETECTORS IN LOCATIONS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.. 5. COORDINATE SHUT -DOWN OF ALL MECHANICAL AIR SYSTEMS WITH DIVISION 15. 6. COORDINATE CONNECTION OF SPRINKLER WATERFLOW SWITCHES, TAMPER SWITCHES AND BACKFLOW PREVENTER VALVE TAMPER SWITCHES WITH THE SPRINKLER CONTRACTOR. SWITCHES ARE FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR. PROVIDE CABLING, WIRING CONNECTIONS AND SUPERVISION TO ALL SWITCHES. 7. CONDUIT SHALL ENTER INTO THE FIRE ALARM PANEL ONLY IN ARES APPROVED BY THE EQUIPMENT MANUFACTURER. 8, ALL EXPOSED VERTICAL CABELING BELOW THE JOIST AND GIRDERS SHALL BE INSTALLED IN METALLIC CONDUIT. 9. ALL VISUAL NOTIFICATION CIRCUITS SHALL BE SYNCHRONIZED. 10. APPLICABLE CODES: NATIONAL FIRE ALARM CODE, NFPA 72, 2002 EDITION. A+2B 10 OF CE 11 / O \ / \ r N7., � / 75 1-tdP K Lc Li-102 1 LI.103 I 2 a L1-104 t Lt-105 r \ A+6B PERMIT #-n--1506 NI-2 75cd -- a+2B Lt1tQ& REVIEWED info { rd Fie Pr v DI, fax a c �7- 05 0 0� CM H1 N L O101 .03 _ CD LO N d' .... 90� U :0)9 vNj -�-+ CU -°ILL X �0 J 7 uO L a "w14. I-L11 � G) o 0) C0 1!�1 W © •i o� _jo al co C .r- w d 0 z 0 Ln I --I WW 1 C� E V1 I w z U N O y a DRAWING NO. SCALE: FA-101 1/4" = V-0" DRAWN BY: DATE: T. BLANC 02/21/07 APPROVED BY: DATE: AR �11{DM1.. DD'/�'��Wj��/f,E�),7N�T0 �� y�.('�� /�ffy2//21 /07 1Inc. sv Low Voltage Systems Contractor EF 0000043 U.L. SZ4158 106 Commerce Street, Suite 103 Lake Mary, Florida 32746 Phone: (407)771-2020 Fax: (407)771-2030 SEAL.