Loading...
HomeMy WebLinkAbout1000 WP Ball Blvd 06-463 Fire alarmCITE' OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091. * FAX #: 407-330-5677 DATE: �_ :'� -� PERMf' N: BUSINESS NAME / PROJECT: 13 ADDRESS: 9( --, ice'; F, /iS �►,ti PHONE NC�`)� JCS dn FAX NO.: C_ -�-�. CONST. INSP. [ ] C / O INSP.:[ ] REINSPEC"PION (] PLANS REV1E W�<p F. A. F.S. [ ] HOOD [ ] PAINT BOOTFI (J BURN 13F.MIT [ J TENT PERMIT f ] TANK PERMIT [ ] OTHER ,r TOTAL FEES: $ C) (PER UNIT SEE BELOW) �C COMMENTS: Address / Bldg. ## / Unit ## 1. 2. 3. 4, 5, 6. 7. 8. 9. 10. it. 12. 13. 14. 15. 16, 17, 18. 19. 20, Square Footage Fees per Bldg. / Unit Fees must be paid to Sanford Building Department, 300 N. Park Ave„ Sanford, FL 32771 Phone N -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of Sanford Florida Sanford Fire Pv r—retee 6YDivision - Applicant's Signature �- GENERAL • NOTES 1, THE INSTALLING CONTRACTOR MUST PROVIDE THE FIRE `ALARM CONTRACTOR WITH ACCURATE MARKED UP DRAWINGS SHOWING ALL JUNCTION BOXES, TERMINAL CABINETS, DEVICE LOCATIONS, CABLE ROUTING, ETC. FOR THE USE IN MAKING "RECORD DRAWINGS". THE FIRE ALARM COMPANY WILL REVISE DRAWINGS ACCORDINGLY. 2, CONDUIT ROUTING AND CONDUIT SIZE SHALL BE DETERMINED BY THE CONTRACTOR, IN C'ONJUNCTIO11 WITH (NEC), AND INDICATED ON THE RECORD DRAWINGS. CONDUIT FILL SHALL NOT EXCEED 40 0. 3. FIRE ALARM WIRII`1G SHALL. BE INSTALLED PER NEC, MANUFACTURERS INSTRUCTIONS, AND THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ). 4. SMOKE DETECTORS SHALL BE MOUNTED IN ACCORDANCE WITH NFPA 72. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR --FLOW NOR CLOSER THAN THREE FEET (3 FT) OF ANY AIR SUPPLY DIFFUSER, 5. ALL. WORK SHALL BE DONE IN ACCORDANCE WITH ADOPTED EDITIONS OF U.B.C. TITL'S 19, TITLE 24, NFPA, AND AMERICANS WITH DISABILITIES ACT (ADA) AS REQUIRED BY THE GOVERING AGENCIES, 6, PRIMARY POWER SOURCE (120VAC) TO FACP AND POWER SUPPLIES MUST BE ON A DEDICATED BRANCH CIRCUIT, FROM THE EMERGENCY GENERATO (IF APPLICABLE), WITH THE DISCONNECTING MEANS MARKED "FIRE ALARM CONTROL CIRCUIT". THE LOCATION OF THE DISCONNECT MUST BE. IDENTIFIED AT THE FACP AND POWER SUPPLIES. ALL FIRE ALARM CIRCUIT BREAKERS MUST BE CLEARLY MARKED AND MECHANICALLY SECURED TO PREVENT ANY UNAUTHORIZED TAMPERING. 7, WHEN POWERING UP THE FACP (DR REMOTE POWER SUPPLIES BE SURE TO' APPLY AC VOLTAGE BEFORE DC VOLTAGE, WHEN POWERING (DOWN, REMOVE DC SUPPLY BEFORE AC DISCONNECT, 8, DEVICE POLARITY MUST BE OBSERVED, 9, ALL INITIATIP-IG AND NOTIFICATIOI'�l CIRCUIT WIRIhIG MUST BE SUPERVISED FOR CIRCUIT INTEGRITY. 10. ALL WIRING, INCLUDING `:SHIELDS, MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 11, STROBE DEVICES SHALL BE SYNCHRONIZED. 12, AUDIBLE DEVICES SHALL USE SYNCHRONIZED TEMPORAL (CODE 3) TONE. 1 3, ALL DEVICES SHALL BE OPTIONALLY LABELED WITH THEIR ADDRESS OR CIRCUIT NUMBER. ALL ADDRESSING SHALL BE NOTED ON THE RECORD DRAWINGS. 14. PROVIDE WEATHERPROOF NEMA ENCLOSURES TO ALL DEVICES THAT ARE EXPOSED TO THE ENVIRONMENT. 15, DIFFERENTIAL PRESSURE TESTING FOR DUCT DETECTORS MUST BE PERFORMED BY THE MECHANICAL CONTRACTOR AFTER AIR HANDLER SYSTEMS HAVE BEEN BALANCED. A WRITTEN COPY OF THESE TESTS SHALL BE TURNED OVER TO THE ENGINEER PRIOR TO SYSTEM FINAL. 16, ALL DUCT DETECTORS TO BE INSTALLED PER MANUFACTURER INSTALLATION INSTRUCTIONS AND ALL APPLICABLE NFPA, UBC AND UMC STANDARDS. 17. ELECTRICAL CONTRACTOR TO PROVIDE ALL CONDUIT AND STANDARD BACK —BOXES AS REQUIRED TO COMPLETE THE PROJECT. 18, ALL JUNCTION BOXES MUST HAVE RED COVERS AND MARKED "FIRE ALARM" IN LEGIBLE LETTERING. 19, ALL FIRE ALARM DEVICES MUST BE INSTALLED IN A PROPER BACK BOX. NO DEVICE SHALL BE INSTALLED WITHOUT A BACK --BOX, 20. PROVIDE PROPER GROUI`'IDING OF FIRE ALARM PANEL AND REMOTE POWER SUPPLIES BY MEANS OF GROUND ROD, OR COLD WATER C:OPPER PIPE IS ACCEPTABLE IF WATER METER f-S STRAPPED, 21, INITIATING DEVICE CIRCUITS (IDC) AND NOTIFICATION APPLIANCE CIRCUITS (NAC), ARE TWO WIRE CLASS "B". T--TAPPING IS NOT ALLOWED ON ANY OF THESE CIRCUITS. 22, SIGNALING LINE CIRCUITS (SLC) ARE TWO WIRE DATA COMMUNICATINS CIRCUITS, T--TAPPING IS ALLOWED ONLY AS INDICATED 01,,1 THE DRAWINGS, BATTERY CALCULATION WORKSHEET FIRE ALARM CONTROL PANEL NUMBER CURRENT TOTAL OF PER DEVICE CURRENT DEVICE DEVICES ALARM SUPV. ALARM SUPV. Unirn0de 10 1 0.245 0.065 0,245 0.065 Annunciator 1 0,04 1 0.023 004 0.023 PLIII Stations 4 0 0 0 0 Smoke Detector 1 Q.1 0.0009 0.1 0.0009 Duct Detector 3 0,07 0.015 0.21 0.045 Remote 'Test Device 3 0.Q08 0.012 0, 0.036 VVgter Flow 11 0 0 0 0 Tamper 1 0 0 0 0 Lock Box_ I 0 0 0 0 LED-101M 1 0.Q17 0 0.017 0 Power Supervision Relays I 0.025 0.025 0.025 0.025 0 0 0, 0 0 0 0 0 0 0 0 0 Q 0 0, 0 �� TOTAL$ � � 0.6371 0.1949 A. TOTAL SUPERVISORY' CURRENT � � 0,1949 � _ _ E (24 OR 60 HOURS) B. STANDBY Wf1M --- � 24 , C. TOTAL SUPERVISORY CURRENT X STAND BY TIME 4.6776 D. TOTAL ALARM CURRENT 0.637 I. ALARM IN HOURS (5 MIN = 0.084 FIRS) 1 0.084 F, TOTAL ALARM CU RRE INT X ALARM TIME 0.05351 G. RECORED AMPERE HOURS Add line C & F 4,73-111 H. TOTAL REQUIRED AMPERE AFTER A 1.2 DERAvf 1NG FACTOR 5.67733 (INSTALLED BATTERY WILL BE 8 AH FIRE ALARM DEVICE LEGEND QTY PER FLOOR SYMBOL DESCRIPTION MANUFACTURER MODEL PART NUMBER BACK -BOX INFORMATION G 2 3 4 EOL , END OF LINE DEVICE Re=RESISTOR FIRELITE 10 0 0 0 0 PROVIDED WITH FRCP PANEL RI=RELAY SYSTEM SENSOR PAM2 1 0 0 0 0 FACP FIRE ALARM cot,iTROL PANEL FIRELITE UNIMODE-10 ADT—UNIMODE-10 1 0 0 0 0 N/A FCPS REMOTE POWER SUPPLY FIRELITE FCPS-24F 1 0 0 0 0 N/A FSA FIFE SYSTEM ANNUNCIATOR ALARM FIRELITE ADT--LED-10 ADT—LED-10 1 0 0 0 0URFAGE: EMI —FLUSH: ;:3—GANG, 2 3/16" DEEP (MIN) (SEE NOTE' 23) ' FIRE. LITE P/N 10103 FAG FIRE ALARM COMMUNICATOR FIRELITE N/A N/A — --' — -- — COMM.UNICATOR INTEGRAL TO PANEL ❑�� PULL STATION FIRELITE N/A BG 12 4 0 0 0 0 C0 HEAT DETECTOR R/F=RATE OF RISE/FIXED 13,E HD— 01 0 0 0 0 0 SURFACE: OCTAGANOL OR 4» X4» X1--1/2' R/F=RATE OF RISE/FIXED 200 HD—r02 0 0 0 0 0} SEMI -FLUSH: OCTAGONAL OR DIRECT MOUNT (USE REVERSIBLE MOUI',ITING PLATE INCLUDED F=FIXED 135 HD—�03 0 0 0 0 0 WITH DETECTOR) F=FIXED 200 HD-604 0 0 0 0 0 FK_B_1 KNOX BOX (iF REQUIRED) 1 0 0 0 0 C?)�R SMOKE/HEAT DETECTOR N/A N/A 0 0 0 0 0 , SMOKE DETECTOR SURFACE; OCTAGANOL OR 4"X4"X1-•-1 /2" — P=PHOTOELECTRIC 2151 N/A 1 0 0 .0 0 SEMI —FLUSH: (DCTAGONAL OR DIRECT MOUNT (USE REVERSIBLE MOUNTING PLATE INCLUDED 1=IONIZATION SYSTEM SENSOR 1151 N/A 0 0 0 0 0. WITH DETECTOR) DUCT SMOKE DETECTOR INSTALLED BY OTHERS N/A DH100ACDCLP 3 0 0 0 0 SYSTEM SENSOR V FLOW DETECTOR BY OTHERS N/A N/A 1 0 0 0 0 PRESSURE DETECTOR BY OTHERS N/A N/A 0 0 0 0 0 t� TAMPER DETECTOR BY OTHERS N/A N/A 1 0 0 0 0 77 L"J MINI —HORN N/A N/A N/A 0 0 0 0 0 HORN/Sl•ROBE < SYSTEM SENSOR N/A P1224MC 5 0 0 0 0 - `:SEMI —FLUSH: STANDARD 4"X4"X1-1/2" OR 2"X4*'X1 —7/8" BOXES l 'JXXc SURFACE; SEE DETAIL WP HORN/STROBE � XXc N/A N/A 4P1224MCK (7 0 0 0" 0 - - - - SURFACE; USE WBB WEATHERPROOF ^BACK —BOX ,0� ;{ ,c STROBE SYSTEM SENSOR N/A S1.224MC 7 0 0 ;Ord 0 SEMI —FLUSH: STANDARD 4"X4"X1-1/2" OR 2"X4"X1-7/8" BOXES SURFACE: SEE DETAIL XX�. C STROBE SYSTEM SENSOR N/A S1224MCK .4 0 0 '0" 0 SURFACE: USE WBB WEATHERPROOF BACK —BOX '—] RTC S REMOTE ALARM INDICATING/TEST SYSTEM SENSOR N/A RTS451 3 0 0 0 '0 KHS ANSUL DEVICE BY OTHERS N/A N/A 3 0 0 0 0 CONNECT FAN SHUTDOWN RELAX` R BY OTHERS N/A N/A 1 0 0 0 0 CONNECT BATTERY CALCULATION VVORKSHEET PS '#1 NUMBER CURRENT TOTAL OF PER DEVICE CURRENT DEVICE DEVICES ALARM SUPV, ALARM SUPV. FCPS . 1 Q,145 0,065 0,145 0,065 0 0 0 0 Horn Strobe 75cd 5 0,167 0 0.835 0 Strobe 75cd 11 0.16 Q 1,76 0 0 0 0 0 Fan Relay `I 1 0 1 0 0 0 0 0 0 Q 0 0 Q 0 0_ TT . 0 Q 0 _0 0 0 0 0 0 Q 0 0 0 0 _. 0 0 0 0 0 0 Sync Module 1 0.0'11 0 0,011 0 TOTALS 3.751 0.065 A. TOTAL SUPERVISORY CURRENT 0.065 24 B. STANDBY TIME (24 OR 60 HOURS) C. TOTAL SUPERVISORY CURRENT X STAND BY TIME 1.56 D, TOTAL ALARM CURRENT _­7­7 3.751 E. ALARM TIME IN HOURS (5 MIN = Q.084_HRS) im ^0 084 F. TO""I"AL ALARM CURRENT XALARNI TIME I Q.31508' G. REQUIRED AMPERE HOURS Add line C & F 1.{37508 H. TOTAL REQUIRED AMPERE AFTER A 1,2 DERATING FACTOR � , 2.25.01 BATTERY BACKUP 7 AH BUILDING INFORMATION GENERAL DESCRIPTION: SINGLE STORY RESTAURANT OCCUPANCY TYPE: OCCUPANCY LOAD: 218 11 NEW ❑ EXISTIIN(; IN ASSEMBLY ❑ DETENTION/CORRECTIONAL ❑ EDUCATIONAL ❑ ONE—TWO FAMILY DWELLING []DAY—CARE ❑ LODGING or ROOMING ❑ HEALTH C�RE ❑ HOTEL/DORMITORY ❑ AMBULATORY HEALTH CARE ❑ APARTMENT ❑ RESIDENTIAL BOARD & CARE ❑ MERCANTILE ❑ BUSINESS ❑ INDUSTRIAL SPECIAL STRUCTURE/HIGH--RISE DOES STRUCTURE HAVE AUTOMATIC 'SPRINKLER S"(STEM? N 0 ❑ PARTIAL M FULL R'E�IEV�� five P-ter Dive Date, DRAWING' SCHEDULE FA-1.0 GENERAL FIRE ALARM INFORMATION FA-1.1 FIRE ALARM LA`(OUT FA--1.2 FIRE ALARM Pk,IEL & DEVICE WIRING DIAGRAMS FIRE ALARM DETAILS OPERATION MATRIX I r r r' r i r• :a r s' including s if a for a and d A � r 1 r This de i n i, udin � is t is drawings, � n �i n once s 's t property T 't f i 'r r r r r e c t i he r e t of � Security S �.e ns In„ DT and is furnisted on a „anfide r a' with ha x re understanding a r' i •v'I I basis, s ss d u Je s � a recipient r r'r� •r t nt i t e t n.i n that k, will not be Bald transferred, copied, or used the detriment 1 i 'g r 9 9 F • �] � P : a k d d la e det r er t of � T without written rrru.slan. The re.i 7ren further agrees - no o �..-I � P r specific ' purpose � r r �, •^- _ ,—.._�..— p P y_ y y � �' • �P 9 _ P _— � � p`a {, t g es t t .i 4ose the vanterrt°y to any .other. party except far the $pa.ific purp�„v cantra,tjd for ,vith ADT. ADT makes no rape3�entations as to the operability or accuracy of any systerrrs, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. 70 a a TO F ACP TO iN/,AU FK _HS1 FK-H-Sl lip FACP I 75c 0 75c ,I �I75c, 61 This design including specifications, drawings, and design concepts is the property of ADT Security Systems, Inc. (AI and is furnished on a confidential basis, with the expressed TO FACP ,I IV I r I J Mount Lock Box 6A.F.F. 0 FE07L Z7 KB Re FE-0- -L] Z Re 4 75c[T-� 75c V1' IIIi-ILE VTU_1 (e) R that it will not be sold, transferred, copied, or used to the detriment of ADT without written permission. The recipient further agrees not to disclose the contents to any other party except for the 107 a UNIMODE-10 RISER DIAGRAM PS FACP F SA L Z 1 L�O Re mo--Li Z 2 Re FE-0-LI Z 3 Re L-] 1--1P ni Z 4 11 P FE—O - R e P Elp FE-0-LIZ5 Re �F- _�I __1 - FE07L IMZR'e RTU-3 RTU-2 Rl RT U - 1 MUA-1 [K::B:i [wo-L7 _iZ Re J<HS K �HS KHS Z'9 EOL R e 75c 75c WP C) WP WP WP 75c 7r>c « 75c,'L]Re NAC 1 7 Sc Sc")c 75c 75(-., 75c 75c 75c 75c 75c 75c - 75c IELIRe NAC2 OFFICE WALL ELEVATION CONDUIT -] IAC_;CESS _Vtt WALL RJ31 PHONE JACKS (BY FOCUS OWNER) CADET 6" DEDICATED 1 20VAC FCPS REMOTE UNIMODE TEST 200PLUS STATIONS tin 3" THERMOSTATS V-1 1" 4'- 3 4 - 6 AFF AFF 00 SAFE DEDICATED 120VAC REQUIRED FOR FA SYSTEM PLUG-IN POWER TRANSFORMER WIRE TYPE LEGEND IDC 18/2 FPL/R/P NAC 14/2 FPL/R/P FSA 16/4 FPL/R/P 24VDC AUX POWER 14/2 FPL/R/P RTS (2) 22/4 FPL/'R/P AUDIO 14/2 FPL/R,/P contracted for with ADT. ADT makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. TRI CON CONSULTING ENGINEERS 777 S. Harbour Wand BNd, STE 870, TAMPA, FL 33602 813.227.9190 FAX 813 .227. 9195 Certificate of Authorization No. 00008363 SEAL DENNIS E. VANN FL. PE, #57620 SMOKEY BONES STORE #7632 1000 WP Ball Blvd. Sanford, Fl Stamp Area: REVISIONS No. Date Description 1.0 03/22/05 REVISED FLOOR PLAN 1.5 10/10/05 SUBMITTALS i tyro Ire & tecurity CAEi ADT Security Services, / 8607 Roberts Inc. Systems Sales & Dr, Atlanta, Go. Engineering 30328 678-585-5800 Budding Type P-5 R rawn Y: EFJ Dote: 03 14/05 Checked By: MDS Date. 03/14/05 DWO File Name: SB SanfordFL BAFA Sales Consultant: Pete Mar shah Title: Fire Alarm Layout Scale: 1/411= 1 1 Sheet: FA- 1. 1 16/4 AWG --� SET DIPSWITCH — 6 TO ON/OPEN BAAd9 OOVa7NAWN-� C ( r1 A a N C Cj ®a M N ®a _____ 4- C,,®a O+� tv N 0 a 00 OJ ADT-LED- 10 REMOTE ANNUNCIATOR N miral Mwli MIN IN J INSTALL 120 Ohm TERMINATING RESISTOR C- W 3 0 a. 0 U W 1% W m L W U C-i I I 1 000otm m d )j ®®®® L UN MODE-10 CONTROLS and INDICATORS r-]AC POWER [TROUBLE �JALARM ❑SUPERVISORY RESET SILENCE MODE F-11 M F 3 1 F F]� F FE ][71 7 o [91F D ] EVENT FAIaFBIFcI FRONT PANEL SWITCHES RESET SILENCE MODE UP ARROW (ACK) DOWN ARROW (ACK) 1 st EVENT ENTER/STORE DIGITS 0 thru 9 LETTERS A thru F PANEL. INTERCONNECT DETAIL_ 0 fl 00 0) — W W W W W W W W W W z z z z z z z z z z U 0 0 O O O O O 0 0 NONE.■mm■mmo■ 011112-2 10 9 DISPLAYS ALARM — RED LED TROUBLE — YELLOW LED SUPERVISORY — YELLOW LED AC POWER — GREEN LED FOUR, SEVEN SEGMENT DISPLAYS — RED PRIMARY PHONE LINE ACTIVE — RED LED SECONDARY PHONE LINE ACTIVE — RED LED 'KISSOFF' SIGNAL FROM CENTRAL STATION — GREEN LED SILENCE — YELLOW LED MODEM — GREEN LED LOCAL SOUNDER A PIEZO SOUNDER PROVIDES SEPARATE AND DISTINCT SOUNDS FOR ALARM, TROUBLE, SUPERVISORY AND CRITICAL PROCESS MONITORING CONDITIONS PHONE CONNECT ON DETAIL DMARC LINE 3 RED-0 nu GREEN 3BACK B V) TELCO YELLOW. LACK W LINES rM RJ CORD o LINE 4 Cl- � RE iu Q GREEN RE (Q a ,(� GREEN 0 �•lOq( � � 3BU%Y( U' YELLOW �� LACK YELLOW 0 LACK RJ CORD RJ CORD PRIMARY SECONDARY PRIMARY LINE LINE LINE IM PRIMARY 0 PRIMARY — O PORT PORT SECONDARY PORT UNIMODE BURGLAR PANEL PANEL NOTES: 1. THE UNIMODE PANEL WILL NEVER SEE A LINE FAULT IF IT IS WIRED BEFORE THE BA PANEL. 2. THE BA PANEL WILL NEVER SEE A LINE FAULT IF IT IS WIRED TO THE UNIMODES SECONDARY LINE. 3. BA PANEL WILL SEE LINE FAULT IF UNIMODE SEIZES SECONDARY LINE FOR MORE THAN ABOUT TWO MINUTES, WHICH IS OK. SYSTEM OUTPUTS 12AWG SUPPLIED BY EC +- - TB1 O 0 O V� J1 0 0 d p, 13 0 [:]AC POWER TROUBLE ALARM ❑SUPERVISORY RESET SILENCE MODE F-110 ❑OD FElEloo o F]F81 F91 FD EVENT [ Al M EB] E] SNORE Q a 0 z 0 U W V) O 0 TELCO PRIMARY LINE TELCO SECONDARY LINE TRANSFORMER 1 — TRANSFORMER 2 (IF REQUIRED) — BATTERY — OFFICE/PANEL SMOKE DETECTOR WIRING & TERMINATION DETAIL TB5 H TERM 6 PANEL SMOKE DETECTOR TB5 TERM 5 OPERATION MATRIX SYSTEM OUTPUTS CONTROL UNIT NOTIFICATION MISC. ANNUNCIATOR G<5 �P JQ of Pr'\�Q o0 PS �J G O O 0 P� PG G� "�� QG C�� '�� Q�F � G�J '�Q-°•�a '��.�C� °��0� ,r`� C,,�J A B C D E F G H I J K 1 SPRINKLER WATERFLOW 1 2 SMOKE DETECTOR • . • . • • 2 (EXCLUDING ELEVATOR SD) 3 MANUAL STATION0 9 0 0 03 4 DUCT SMOKE DETECTOR 0 0 0 0 0 40 4 5 VALVE TAMPER 0 e 0 5 6 FIRE ALARM SYSTEM AC • . • . 6 POWER FAILURE 7 FIRE ALARM SYSTEM LOW • 0 • • 7 BATTERY 8 OPEN CIRCUIT 0 0 0 8 9 GROUND FAULT « 9 10 WIRE —TO —WIRE SHORT • • • • 10 (SLC & NAC) 11 WIRE —TO —WIRE SHORT (IDC) 11 12 LOSS OF CARRIER 12 13 FIRST FLOOR ELEVATOR • 0 • • • 0 119 13 SMOKE DETECTOR 14 SECOND FLOOR ELEVATOR • • • • • 14 SMOKE DETECTOR 120VAC/20A DEDICATED CIRCUIT SUPPLIED BY EC O0 � o 00 o 00000 W D` a a. cn r7 CV U U U U a a a z z z z 0 ECPS--24FS6 SYSTEM WIRING DIAGRAM FOR 4-WIRE DUCT SMOKE DETECTORS ({) F AVAILABLE POWER INPUTS AVAILABLE POWER INPUTS TO UNIMODE- l u RESETTABLE POWER (-) W9 10 10 A B C 9 A B C VO&� &0m 24V 120 24V 120 VAC VAC 1220/240 1220/240/ J VAC I VAC 0 1 ALARM FAN AUXILIARY SHUTDOWN SHUTDOWN, I I FOR MFAN XSHUTDOWN, ETCILIARY S I l GR W 16 6 ,11c�7� 7 18 8 16 6 17 7 18 8 q (- iQ_ _ I I C (� PAM--2 NO' NC C NO C NC NC NO NO C NC ! OR Y BU 0° 4 1 1 tp -< [> C! ALARM AUXILIARY CONTACTS SHOWN ALARM AUXILIARY CONTACTS SHOWN IN STANDBY I IN I CONTACTS TRANSFER DURING ALARM CONTACTS TRA SFERD DURING ALARM AS INDICATED BY ARROWS AS INDICATED BY ARROWS SUPERVISORY TROUBLE CONTACTS I I SUPERVISORY TROUBLE CONTACTS 14 3 -o--. 14 3 TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS CONTACTS OPEN WHILE DETECTOR PCB OR POWER IS REMOVED OR WHEN TAMPER FEATURE TIMES OUT REMOVED OR WHEN TAMPER FEATURE TIMES OUT OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL OPEN CONTACTS SIGNAL TROUBLE CONDITION TO PANEL ALARM CONTACTS SHOWN I ALARM 5 CONTACTS SHOWN INITIATION OPEN IN CONTACTSCLOSECONTACTS STANDBY INITIATION OPEN IN STANDBY CLOSE CONTACTS 4 4 IN ALARM CONTACTS 4 Q IN ALARM MULTIPLE FAN SHUTDOWN (INTERCONNECT) 1 6 A B C 1 6 A B C 0 E (D0 0 O 0 O 12 16 12 16 FAN CONTROL DETECTOR 1 DETECTOR 2 SYSTEM SYSTEM CONTROL 1 FAN CONTROL POOWRER [CONTROL POWRER THERMOSTAT U? OTO I THERMOSTAT DETECTORS MAXIMUM 1 6 A B C O 0 O O 12 16 SYSTEM A B C D E F G H I J K I FAN CONTROL CONTROL POWER I THERMOSTAT Construction. f r in herein nl specifically identified o rinformation ntu ess s e c 'I' f m m assemblies, o other contained ed This desi n including specifications, drawings, and design concepts is the property of ADT Security Systems, Inc. (ADT), and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transferred, copied, or used to the detriment of ADT without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with ADT. ADT makes no representations as to the operability or accuracy a any systems, subsystems, as ep y 9 9 9 DETECTOR 10 EOL RESISTOR SPECIFIED BY MANUFACTURER TRICON CONSULTING ENGINEERS 777 S. Harbour Island Blvd, STE 870, TAMPA, FL 33602 813 .227.9190 FAX 813 . 227.9195 Certificate of Authorization No. 00008363 SEAL_ DENNIS E. VANN FL. PE. #57620 SMOKEY BONES STORE #7632 1000 WP Ball Blvd. Sanford, FI Stamp Area: REVISIONS No. Date Description 1.0 03 22 05 REVISED FLOOR PLAN 1.5 10/10/05 SUBMITTALS tyro teire 8c , curity ADT Security Services, 8607 Roberts Inc. Systems Sales & Dr. Atlanta, Ga. Engineering 30328 678-585-5800 Building Type P-5R rawn y: EFJ ate: 03 14 05 Checked y: MDS Date 03 14 05 DWG File Name: SB SanfordFL BAFA Sales Consultant: Pete Marshall Title: Fire Alarm Panel & Device Wiring Diagrams Fire Alarm Devices & Operation Matrix Scale: NTS Sheet: FA-1.2