HomeMy WebLinkAbout500 W Fulton St 05-2237 New constructionJ^,7_1 CITY OF SANFORD PERMIT APPLIC ATION (Construction Trailer)
Permit # : lJ Date: 0 4 -14 - 0 5
`Job Address: 500 W. Fulton Street Sanford, FL 32771
Description of Work: office Building Improvements
Historic District: Zoning: Value of Work: $
Permit Type: Building X Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool
Electrical: New Service — it of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines 1# of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial
Occupancy Type: Residential Conimereial X Industrial 'Total Square Footage:
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than h
Parcel fl: 2 5 -19 - 3 0- 3 0 0- 0 0 9 A- 0 0 0 0 (Attach Proof of Ownership &Legal Descrlptrou)
Owners Name&Address: Sanford Fulton Holdings, LLC.
500 W. Fulton Street Sanford, FL 32771 Phone: 407-322-6841
ContraetorNiuue&Address: CPH Constructors, LLC.
500 W. Fulton St. Sanford, FL
State License Number:
Phone &flax:407-322-6841 / 407-330-O&PactPersou: Sarni Fl-Behiri Phone: 407-322-6841
Bouding Company: N / A
Address:
Mortgage tender: United Heritage Bank
Address: 3001 W. Lake Mary Blvd. Lake Mary, FL 32746
ArchitectlEnginee, CPH Engineers, Inc. Phone: 407-322-6841
Address: 500 W. Fulton St. Sanford, FL 32 771 Fax: _
Application is hereby made to obtain a permit to do the work and hrstallations as indicated. I certify that no work or installation has commenced prior to the
issuance ofa permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit trust be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, IIEA'fERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all ofthe foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
AT"fORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of
this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies.
Acceptance of p unit is verification that I will rwtity the owner of the property of the requirements of Florida Lien Law, FS 713. /
Allvm
Sign- e l -wirer/ gent `)ate Si natureot'C t acto A en Date
�/f1►Yl- TK=
Prin40wner/Agent 's Name Print Contractor/Agent's Name
Signature oI'N ry-State of Flo ida Date Signature ofNotar -State ofFlo 'da Date
P Kimberley S Meton vas P Kimberley S Melton
My Commission DD08Z139 My Commission DwaV34
V � c F (pines February 04, 2006 Q Exp'lree February 04, 201A
Owner/Agent is � Personally l�nown o Me or Contractor/Agent is ^ Personally Krro�tito Me or
Produced ID y Produced ID
APPLICATION APPROVED BY: Bldg: Zoning: �+/� �S�Utilities: FD:
(initial & Date) / (Initial & Date) (initial & Date) (Initial & Date)
Special Conditions: Zt»�! �itC���f fften
It
TOP = 10, 00
N IN V.(:;�'2"RCP)'':':' 78 \
S INV.(42„RCPj=3.70 hh�
t.STANDING WATER) \
In
41.00 --........ _.
I
�.00> �........
CURB >�
INLET
1.3' X 5'
MASONRY
WALL
SET PK NAIL AND
DISK LB 3778 IN WALK
CORNER OF WALL 6' WOOD FRAME FENCE
AT 1.8'E,, O.6'N. w
3
B
I�
I
w
p
W
�?
Q
W I
W
U
w
LO
1'
0vi:#
ZONING SC-3 - APARTMENT USE
N 0"00 00 E
SITE DATA
POINT OF
E i "INN (. PARCEL A = 1.76 Ac.
BIN
EXISTING IMPERVIOUS AREA = 0.42 Ac. BUILDING HEIGHT: 27' 8"
TI-I: A C T C PROPOSED IMPERVIOUS AREA = 1.41 Ac. = 80% WIDTH: 62' TO 40'
FUTURE PARKING ® 1 /200 SF BLDG. AREA
PARCEL B = 2.21 Ac.
EXISTING IMPERVIOUS AREA = 0.24 Ac. NOTE: THE IRRIGATION SYSTEM SHALL
PROPOSED IMPERVIOUS = 1.28 Ac. = 57.92% USE EXISTING RECLAIMED WATER
PARKING REQUIRED ® 1 /200 SF BLDG. AREA
BUILDING AREA = 19,700 SF OFFICE SPACE
PARKING SPACES REQUIRED = 99
PARKING SPACES PROVIDED = 99
HANDICAP SPACES REQUIRED = 4
HANDICAP SPACES PROVIDED = 4
PARCEL ADDRESS: 500 WEST FULTON STREET
OPEN SPACE = 0.67 Ac. = 39.3% (WET DETENTION
EXCLUDED BELOW ELEV. 7.00)
SOILS - URBAN LAND PER SEMINOLE COUNTY SOILS
SURVEY (SEE SITE SPECIFIC SOILS REPORT)
RIBS(
CROSS ACCESS WILL BE PROVIDED
BETWEEN PARCELS A AND B
RB __\ I
348.38'(M) 348'(D)
FUTURE PHASE II
PARKING
90 Owl
ir�i�' ���
0*1$5)3E
121 �M & D
RETENTION
PARCEL B
N 90'00'00" E
C,,, -- VERTICAL CURB -
11
5 SPACES 5 SPACES
160.06' (M & D)
A E 3'R
3aR \3,R 3'R 3'R
UTILITY: CITY OF SANFORD SEWER AND WATER -4- ---
ESTIMATED WATER DEMAND: 450 GPP S FLUSH (`� _ N89'53'54"E �
EXISTING AND PROPOSED ZONING: SC-3 w 175,99' - 64.00
TAX PARCEL ID NUMBER: 25193030001SO0000 NOTE; ,
3 R 3 R x€ 10'R
AND 25193030009C0000 ...._® APR £ , 10'R
WETLANDS: NONE 1. NEW BUILDING SHALL T TO I 10 R I
100 YEAR FLOOD ELEVATION: ZONE X FEMA MAP EXISTING WATER AND S VICE
2. SITE NOT LOCATED LLFIELD 8 SPACES SPACES
No. 12117CO035E _ " , " " " • ' • ' • '
EXISTING VEGETATION: GRASS IN OPEN AREAS PROTECTION ZONE
PROPOSED USE: PROFESSIONAL OFFICE 3. STOP SIGN SHALL B H I 3'R o 3'R
I DENSITY: 1 UNIT/LOT INTENSITY AND STOP B BE 24 -- - - 3
WHITE THERMOPLASTIC M _ W..„ 5' SID.EWAL o o i
.................................................................... 229.8........ ..................................................................................................................................................... ............... .................................................... �.. 3 R o �
INTEGRAL CURB AND SIDEWALK r
STEPS PERVIOUS
I-T'OP = 10.98 �WALK� I STEM WALL PAVERS I w
W s11N11 VV.(I5"C,MP )•=5.93
l Ot- = 11,21
IN INV.(42"RCP)''=5,16
>' =' c INV•,(42"RCp) 5.31
INV(8"PVC)~_81
GRA_1` IN: ET
tf.50
IW\I V(8"PVC)=7,61
C O.
01
ACE
ii
z
tw I
I
G. J >...
c�-
v1
�
I
PARCEL A WOOD
BRIDGE`
GRA T E INLETS
WITH 0.4' CONCRETE
CURBING -•
CLEAN OL1'T'•.,,,
r
SI'AC:E >
CJ
CONCRETE
tZ W
f FI,t1 M E: \ METAL _.. 0' LO Q I
2 2 0-
�\ '`ON •lDCT,: � .. ... __.. TiNL; aTi�I"iY._............„„.................._...._..._
1
32OAKRETENTION
I r7
A7R'EA fl? ,,.,Ob:...R:'D
„CONCRETE
IS �
C.. I
I
`,1= NISH FLOOR
'�`-
v
0
s
A:'I• ROXIMA1 .. ,�✓ ._ I La ELEVA LION=12.94
10
00
I !
TOIL OF BANK C„}
G<)
�
Cn
w
00
:
m 3
4, I
(,,
Lo
W
. -.
.a..
..I•' A ES I
n_ . o
U
Z I V) ("
W O
k,ONt:I•?F,. ' E.h, EXISTING
W J 18
,4F'HAL T I='APR Kii`J C AI-'E.
z C:ONG`RE-E U L0 . - (%� = w 20'
a
1. z FINISH FL_C� f€ a m F_ _ 3'R -
-,
` 0,7' MASONR EI.. `,iATION=16.71? (SAVE)
W N as
WALL 1 3,
ONCRETE .STEPS u
.......................
4ND EN'T'I�Y 3 R
�� 4 BUMPER
•
SPACES ���'t;` A..r,
BLOCK
_-_._.. o
(:D() t:.:' .,f * PAVE�.'.ME:GO HC,RAMP
CONCRETE :: n BRICK LO
Lq
WATER LIGHT 0',f...E '� 'ft = TO BE RELOCATED BY PAVERS ° N
FAUCET — ......... FLORIDA POWER CORP. _ 3 R
it <I � �
--•••••• `` TO BLDG. FIRE SR
1 ` EXIST. SANITARY SPRINKLER S M
HANDICAP .Sf... 3 20'R
SIGN -„' 040 I SEWER LATERAL 7' 10'R
a' REDUCED PRESSURE —�
BACKFLOW PREVENTER
FILL AND LANDSCAPE
15' 3' HIGH
ETAI.. SIGN
15
SIGN EASEMENT
.. .............uw.
CONCRETE WALK
STOP
'rf i. S:G
01
I
STOR
S 90*00,00" W
EDGE OF PAVEMENT'
235.28'
STORMl�
RIt� Ir:I-I
ENCLOSED
DUMPSTER
12'X12'CON(
6' CONCRETE PAD
;.PAD
VERTICAL
CURB I
�
rti
00
�
w
U
N
Ln
�
N p
O
vi
0I —
Lu
Z
5W
MG
li
a
a
1
V
�n
N
CO
iv
O
°O
N
ado
cD
Cl)
E
O
o
Z
OOD
N
(1)
cv
1,-N
p
CO
O
K
O
m
2
(h
cd
o
m
ch
C
'N
0
U
5
LL
i ,
Q,
c
o
L
O
W
LL
c
CD
N
a
Q
ip
77
7
-6
X
V
O
O
D-�
O
"
o
,�
a
mLL
N
u)
w
U
c
O
3
w
S
W
O
z
;
Q
Of
U
z
Q
0
}�
F-
(�
rr
Ldp
L�
0
of
O
U
�
O
w
O
U
W
a
CL
a-
�
QN
N
o
O
I
O
i
N
I
O
of
N
N
N
z®®a®
+'
r
O
O
r
O
O
r
O
O
�
O
O
W
a.
z
m
Z
m
;�
ti
!rl
Lo
Lo
ca
3
O
011
m
18'
N
�i/
W (_
N Z
0
N
a
?
L)
Q
m
(1)m
c
D
c
3
m2'
tY]
2
U
m
Qi
O
Cl.
o
o
m
cn
M
Z■
SR
a
Z
-
f
r�A(SAVE)
Z
3'R
3'R g
r
j
V♦ 0
5 M
1i
I
o
a
O
DWLL
Z
Z W
PERVIOUS
a
Z 0
Lu w
ofLo PAVERS
O
W 0
Z
LL
V)
WOOD FRAME
�
('j Z Z
TO CITY OF SANFORD INTEGRAL
Lu FENCEZ Z a
3 THIS AREAui
to _
SPECIFICATIONS CURB S89'S2'42"W a 17.3' W W
LLI EXIST. CPH SIGN
_... _f--
-� ,.—..... TO REMAIN 2 � 34 i> 41.00' (n
i n
--
u� A= :N N o a
RECLAIMED
- 2 BLOW -OFFS PLUG ... _....... H,NDICA:'� ' 18.,?' "'� NTRY 3 o "i:.,, 4T - o -- W
r,T
�dATit R LINE 7 CONCRETE FOR FUTURE EXTENSION ,,•- -_- ..:.: �: • � � .> � C ' 1 `'VERTICAL R-23.00 10 R � � � 3'R ....... .-, ....... � _._-. n _ � V
CURBING �1 PJ
t.l �i: .
I e+` , N
FH & V L=36.13 STOP c�
.,�. f ..... -� !••: ,t•f .�.. ;:f, �> f��°,K CURB q.�_ TAN_ CF,S'f'-�---
�:FT 23.00
SIGN S90'00 00 W 47.37'
•
N�� E CONCRETE WALK
K IGA .IC�P: (*- E " .., 8"D.I.WM �0" 508.44'(M) 508.50'(D) ' „ ... .
(X " r.^ L� ' '\ -, - `; w ; y i i n r f ,.......,...,. ....... ....... «....,. ......, ............ t r
LIGHT / 2 _8 ,AN _vEa'I h LINES P,�I _
35 R m o
O
t_. _.. r .... _. _.................... r�................ O N Ln
POLE i 8 DR 11 W W N � CL
PAVEMENT 116 POLYETHYLENE ,.- �` :�; I ��' -- � U
Cc_: `CRET CUPEiI G II
EDGE OF f'AVf;=MENT�' SAW-CJT AND REMOVE EXIST. _...W._.W..........................._..___.........._..............._............-..-...-......-.............._.._..._._.._... .... .-_._.......�._.__...... -
i� ® SIDEWALK CONNECT AND EXTEND 1 0 /4�CVT TO XIST. CONNECT TO EXIST. CLEANOUT CONNECT TO O 6 Lu o0
i INV. 9.25f FIELD VERIFY EXIST. SIDEWALK ai z N
1 — EXIST. WATER METER PRIOR TO CONSTRUCTION _
__ _._ .........._. _ s) ai
._... "..... �T ,._ ...-__...� _.... �-.�. _..._ _._..--. _ RAISE TOP OF EXIST. CLEANOUT -.. �__ ._ ...._.._.__-.__.- � Q LL
RAISE TOP OF EXIST. TO NEW SIDEWALK GRADE
i CLEANOUT TO NEW VERTICAL CURB
ii S •-', S WALK GRADE
66° RGHT OF W XY I � � Exls RECORD DRAWING _• _ a �
//11 T. SANITARY Z
V THIS RECORD DRAWING IS BASED ON INFORMATION RECEIVED BY THE CONTRACTOR AS
i� SEE SHEET 10 OF 10 SEWER LATERAL TO LOCATION AND DETAILS OF THE FACILITIES ACTUALLY CONSTRUCTED. THE ENGINEER
HAS PROVIDED LIMITED INSPECTION OF ONSITE CONSTRUCTION AND HAS OBSERVED THAT
ZONING SC-3 FOR OFF -SITE WATER THE READILY VISIBLE FEATURES ARE INSTALLED IN GENERAL ACCORDANCE WITH THIS
00, MAIN ROUTE DRAWING. 0
..._.........___--- --- ------- _------ ............. _ - ------ .._.......................
--
,............. HOWARD L. WRAY, JR., P.E.
f 55557