HomeMy WebLinkAbout3941 W 1 St 06-758 SignCITY OF SANFORD PLIOUT APPLICATION
RECEIVED
Permit #: V! { _ `s�— - Date:- 11/11/2004� H
.lob Andress: 3941 W. S t-ate—Ra)ad-46 Sanford, FL 32771 'V
Description of Work: Install (1) 5' x10' Ground Sign TOTAL SQ FT 50.00
Historic District: _ Zoning:. Value of Work:
Permit 'Type: Building Electrical-- Mechanical Plumbing _— Fire Sprinkler/Alarm Pool
Electrical: New Service — ft of AMPS _ Addition/Alteration _ Change of Service Temporary Pole _
Mechanical: Residential Non -Residential Replacement Ncw (Duct Layout & Energy Cale. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines_— it of Gas Lines _
Plumbing/New Residential: # of Water Closets _ Plumbing Repair — Residential or Commercial _
Occupancy Type: Residential Commercial Industrial Total Square Footage:
Construction Type: # of Stories: # of Dwelling Units: — Flood Zone: _ (FEM- A form required for other than X)
�+•momomsamrw -—�..-......__._... -wm amwonm __ -- - - uswwaxaw:iowawa®x®omo,®
Parcel #: 28-19-30-506-0000-0120 (Attach Proof of Ownership & Legal Description)
Owners Natne&Address: The Recovery Room of Central Florida, Inc.
3941 W. State Road 46_ Sanford, FL 32771 phollC:_407-936-0051
Contractor Name & Address: Charles Wi ngo Signs, Inc. _
P.O. Box 1172 Apopka, FL 32704-1172 State License Number: ES12000114 _
Phone &Fax: 407-886-8131/407-RP6-1406 Contact Person: _Charles S. Wingo Phone: 407-886-8131
Boading Coatpany: n/a
Address: n/a
Mortgage Lender: n/a
Address: n / a
Architect/Engineer: __ Richardson Enqineering _ _ Phone: 407-425-4002
Address: 131 Zelma Street Orlando, FL 32803 Fax: 407-841-7932
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be perforated to meet standards of all laws regulating construction in this jurisdiction. 1 understand theta separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT CN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICF,: In addition to th irern ! C9-6f1IM pZT—Mit, then ay be additional restrictions applicable t tis prog� y ra ma e fou in the public records of
this county, and th aayy be additional permits required other governmental entities such ter/management districts tat ncies, or federal agencies.
Accepianc f pen i i .verific. that I w' sotifythe nor of the property of the r uire et:yS tort ter. L _
11/11/2005 11/11/2005
of-5wnd'r/Agent Date Signature of Contractor gent D `�Illlllllf�/
W. �����
�.N` P�� �di n o har1 es S. Wino ��'ONS&S W. MHOZ,
�p110 �C�J�nt'sName Print Contractor/Agent'sNa ` Co��••'MMIs3roy'•,9����
11/11/2005 Fr/'�bt`r
t * 'Sig�ltamre ofT&&Statc of Florida Date Signature of Notary -State of Florida Date
• w p m * a
#DD 481509 % � z #pp
s o• . o r 0 481509
9• �a: �'°ndadth� p�0;`'' pQ� i9 • Vli • p�```�
/ZUB(/ G/�� �ts X Per}�ona11 Known to Me or Contractor/Agent's X Perponall Known to�{�G�•�•w`••••w F����
//// 4ll�la�1yed ID _11! a Produced i ID n / a y
—tt //lHNilii11�1
APPLICATION APPROVED BY: Bldg: Zoning: _ Z' I L / Utilities: FD:
(Initial & Date) (Initial & Date) (Initial & Date) (initial & Date)
Special Conditions:
01e- }„ lv.', Q olne
"A t
c! Ion
0
z
0
N
W
y "
Q� W
<C l�
LL Q
0-
Li �..
z
D E-1
pq 0
Q �
i-- Q
V
� a-
ry
71
(SEE SHEET 6 )
x
w
SOILS
LEGEND:
DEVELOPMENT
NOTES
9.
PARKING
1.5 SPACES PER EMPLOYEE
TOTAL REQUIRED = 10 PEOPLExi.5 - 15 SPACES
1.
OWNER
THE RECOVERY ROO,!
TOTAL PROVIDED = 16 SPACES
GEORGE TORN
4765 S. SEMORAN BLVD.
10.
SITE
TOTAL LAND AREA = 2.28 AC
20
WAKKA
ORLANDO, FLORIDA 32822
PROPOSED BLDG. AREA = 23,030 S.F.
PH. 407-277-6411
PROPOSED PAVED AREA = 43,883 S.F.
CONC. PAD AREA 1,375 SF
BASINGER
2.
SURVEYOR
KITNER SURVEYING
DUMPSTER AREA 144 S.F.
g
O
DELRAY
2597 SANFORD AVE14UE
TOTAL IMPERVIOUS AREA = 68,432 S.F.
SANFORD, FLORIDA 32773
TOTAL GREEN AREA = 30.899 S.F.
EAUGAWE
PH. 407-322-2000
PERCENT IMPERVIOUS = 68.9%
13
IMMOKALEE
3.
ENGINEER
JOHN HERBERT, P.E.
AMERICAN CIVIL ENGIAEERING CO.
11.
SETBACKS
FRONT REQ. 175 FT. PROVIDED 175 FT. (MIN.)
207 N. MOSS ROAD, SUITE 211
SIDES REQ. 10 FT. PROVIDED 52 FT.& 10 FT. (MIN.)
WINTER SPRINGS, FLORIDA 32708
REAR REQ. 20 FT. PROVIDED 255 FT. (MIN.)
PH. 407-327-7700
12.
FIRE
A HYDRANT AND SPRINKLER SYSTEM PROVIDED
4.
ZONING
P.D.
5.
BUILDING
CONCRETE & METAL CONSTRUCTION - TYPE IV
13.
SIDEWALKS
5' CONCRETE SIDEWALK PROVIDED ALONG S.R. 46
235.00' x 95.00' x 16.00' H
6.
PROPOSED STREET ADDRESS: 3941 SR 46 W.
14.
FIRE LANES
FIRE LANE PROVIDED IN THE FRONT
7.
TAX I.D. NO.:
28-19-30-506-0000-0120
15.
STORMWATER MANAGEMENT
SITE IS NOT IN 100 YR FLOOD ZONE
AS PER FEMA
8.
PROPOSED USE:
AUTOMOTIVE SALES & REPAIR
235.00' x 98.00' x 16.00' H
3
rtOINdS 40 All)
111IM91AgN SNdld
331AAO
16. TRAFFIC CONTROi, DEVICES ALL MARKINGS SHALL COMPLY WITH 'THE F.D.O.T. ROADWAY
AND TRAFFIC DESIGN STANDARDS, MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES, THE CIY OF SANFORD LAND
DEVELOPMENT CODE AND THE NEW F.H.W.A. "OLDER ROAD
USER STANDARDS", 6" EDGE LINE, LANE LINES AND
SINGLE CENTERLINE PATTERNS. ALL DOUBLE PATTERNS
SHALL BE 4". RPM's AT 20' CENTERS WITHIN 200' OF
INTERSECTIONS, 40' SPACING OTHERWISE.
17. TRAFFIC OPERA-i L NS ENGR BEFORE COMMENCING CONSTRUCTION IN THE R.O.W., THE
CON TRACTOR SHALL CONTACT THE F.D.O.T. PUBLIC
WORKS DEPT. AND SECURE ALL RIGHT OF WAY PERMITS
PRIOR TO COMMENCING WORK IN THE R.O.W.
1111111in
I
w
cn
0
W
O
il"
T CQ
o
yl'
V)
V)
18.
SODDED AREAS
ALL DISTURBED AREAS WITHIN THE RIGHT OF WAY AND ALL
POND SIDE SLOPES SHALL BE SODDED.
DATE; .,
!
!
19. WETLANDS THERE ARE NO WETLANDS ON THIS SITE.
20.
DOOR ELEVATIONS
ALL ENTRANCE DOORS AS SHOWN ON PLANS ARE AT PAVED
PARKING ELEVATION, NO SLOPE FROM THE H.C. SPACE TO
PROPOSED ENTRANCE SHALL EXCEED 12:1 & 50:1 FOR
-
PARKING SPACE AISLE. THERE ARE NO CURB RAMPS.
21.
ROOF DRAINS
R0017 DRAINS TO FLOW TO THE PAVEMENT
22.
IRRIGATION PLAN
ALL LANDSCAPE AREAS ARE TO BE IRRIGATED WITH A WATER
CONSERVATION IRRIGATION SYSTEM WITH RAIN SENSORS AND TIMER
N J. HERBERT, 1; P.E.
STATE OF FDA
REG. NO. 39
23.
FLOOR AREA RAT 0
0.231
or
2
C:\]Dk#OHNDWG\PROJECT-A\05355\A05355MASTER.dwg, 10/13/2005 2:31:06 PM