HomeMy WebLinkAbout196 Towne Center Cir 18-2675 PlansS MINO TOWNS CENTER -SPACE 196 TOWNS CENTER CIRCLE, SANFORD, FLORIDA, 32771 PROJECT CODE INFORMATION THE BUILDING SHALL BE IN COMPLIANCE WITH THE MOST RECENT VERSION OF THE FOLLOWING CODES, ALL WITH INCLUDED SANFORD AMENDMENTS: 2017 FLORIDA BUILDING CODE 2017 FLORIDA FUEL GAS CODE 2017 EXISTING BUILDING CODE 2017 FLORIDA TEST PROTOCOLS 2017 FLORIDA PLUMBING CODE 2017 FLORIDA ACCESSIBILITY CODE 2017 FLORIDA MECHANICAL CODE 2017 FLORIDA ENERGY CODE 2017 NATIONAL ELECTRICAL CODE ANSI A117.1 2003 2010 AMERICANS WITH DISABILITIES ACT (ADA) NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS O.S.H.A. EXISTING BUILDING INFO AREA TYPE NOTES EXISTING/RENOVATION ALTERATION LEVEL 2 CISTALLATION OF RESTROOM. OCCUPANCY CLASS OCCUPANCY CLASS NOTES UERLA TI R T 0 SQUARE FOOTAGE AREA OCC. SO. FT. % OF AREA NOTES UNALTERED M 4,686 98% EXISTING SPACE RENOVATED M 104 2% NEW M 0 0% TOTAL 4,790 100% GROSS AREA WITHIN EXTERIOR WALLS ELEMENT REQUIRED PROVIDED NOTES SPRINKLER SYSTEM NO YES PORT. FIRE EXTINGUISHERS YES YES FIRE ALARM & DETECTION NO NO CONSTRUCTION TYPE OCCUPANCY CONST. TYPE NOTES M IIB UNPROTECTED BUILDING MATERIALS ELEMENT TYPE RATING NOTES STRUCTURAL FRAME IIB - EXISTING UNALTERED BEARING WALLS (EXT) - EXISTING UNALTERED BEARING WALLS (INT) - NONE NON -BEARING WALLS (EXT) - EXISTING UNALTERED NON -BEARING WALLS (INT) - EXISTING UNALTERED / NEW FLOOR CONSTRUCTION - EXISTING UNALTERED ROOF CONSTRUCTION - EXISTING UNALTERED P U G FIXTURES OCCUPANTS MALE FEMALE 07. OF FIXTURES TO BE MALE / FEMALE NOTES 73 37 36 REQUIRED PROVIDED MALE FEMALE MALE FEMALE WATER CLOSETS 1 PER 500 1 1 1 1 LAVATORIES 1 PER 750 1 1 1 1 BATHTUBS/SHOWERS NONE 0 0 DRINKING FOUNTAINS 1 PER 1000 1 2 (HIGH & LOW HC) SERVICE SINK NONE 1 1 DIRECTORY ADDRESS CONTACT WASHINGTON PRIME GROUP OWNER 111 MONUMENT CIRCLE CHARRISE WHITE INFORMATION SUITE 3500 TEL: 317-986-8517 INDIANAPOLIS, IN 46204 TENANT INFORMATION MY LITTLE TOWN KIDS LARSON DESIGN GROUP ARCHITECT: 1000 COMMERCE PARK DRIVE ROBERT J. GEHR, AIA, NCARB ARCHITECT SUITE 201 PROJECT CONTACT: WILLIAMSPORT, PA 17701 KARA DEMMIEN TEL: 570.244.2064 SCOPE. OF WORK GENERAL INSTALLATION OF RESTROOM. ARCHITECTURAL INSTALLATION OF NEW INTERIOR PARTITIONS FOR RESTROOM AND INSTALLATION OF NEW FINISHES. STRUCTURAL EXISTING, NO MODIFICATIONS MECHANICAL EXISTING AIR HANDLER UNIT(S) TO REMAIN, NEW DUCT WORK AS NOTED. ELECTRICAL EXISTING SERVICE & PANEL TO REMAIN. INSTALLATION OF NEW LIGHTS, & POWER RECEPTACLES AS NOTED. PLUMBING INSTALLATION OF NEW PLUMBING FIXTURES, WATER CLOSET, & LAVATORY. DEFERRED SUBMITTALS • FIRE SPRINKLER MODIFICATIONS FIRE SPRINKLER NOTE: CHANGES ARE REQUIRED TO THE EXISTING FIRE SPRINKLER SYSTEM UNDER THIS SCOPE OF WORK, THE FIRE SPRINKLER SUB -CONTRACTOR SHALL SUBMIT TO THE BUILDING AND FIRE DEPARTMENTS A FIRE SPRINKLER PLAN AND CALCULATIONS DOCUMENTING THE REVISIONS TO THE EXISTING SYSTEM. THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY STEPS TO PROTECT THE INTEGRITY AND OPERATION OF THE EXISTING SYSTEM DURING CONSTRUCTION. ALL WORK SHALL COMPLY WITH NFPA 13, 1999 EDITION.. l •;s A01 DRAWING INDEX SHEE 0 DESCRIPTION REVISIONS GENERAL INFORMATION G1.0 COVER SHEET/CODE INFORMATION 1 07/20/2018 G1.1 EGRESS/LIFE SAFETY PLAN 1 07/20/2018 G1.2 ADA ACCESSIBILITY DIGRAMS G2.0 SYMBOLS & ABBREVIATIONS G3.0 SPECIFICATION/GENERAL NOTES DEMOLITION PLAN D1.0 DEMOLITION FLOOR PLAN 1 07/20/2018 ARCHITECTURAL A1.0 FLOOR PLAN & INTERIOR ELEVATIONS 1 07/20/2018 A2.0 WALL TYPES DETAILS / DOOR SCHEDULES 1 07/20/2018 A3.0 REFLECTED CEILING PLAN 1 07/20/2018 MECHANICAL M0.1 MECHANICAL SPECIFICATIONS MD1.0 MECHANICAL DEMOLITION PLAN 1 07/20/2018 M1.0 MECHANICAL FLOOR PLAN 1 07/20/2018 PLUMBING PO.1 PLUMBING SPECIFICATIONS PD1.0 PLUMBING DEMOLITION PLAN 1 07/20/2018 P1.0 PLUMBING PLAN & DETAILS 1 07/20/2018 ELECTRICAL E0.1 ELECTRICAL SPECIFICATIONS ED1.0 ELECTRICAL DEMOLITION PLAN E1.0 POWER PLAN 1 07/20/2018 E2.0 LIGHTING PLAN 1 07/20/2018 E3.0 FIR PANEL SCHEDULES & DETAILS PARTMENT 1 07/20/2018 THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR PERMIT. AN ISSUED PERMIT SHALL BE DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THE FIRE PREVENTION DIVISION FROM THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHER VIOLATIONS OF THE CODE. REVIEWED BY: MATT MINNETT SANFORD FIRE DEPT. 'DATE: O Jsz1_1x A PE Rf AIT I;> ;i, tt t7 ; H?ii,L BE CONSTRUED TO BE A Lii_ +_.i � 7 TO P g0C,CEED WITH THE WORK AND NOT AS A J 2�18 a': T Ht�PIl '' TO VIOLATE, CANCEL, ALTER OR SE`( ANY Fri f � J- THE PROVISIONS OF THE TECHNICAL 1 .,R S -I..AL1. ISSUANCE OF A PERMIT PREVENT �a �. � -';r c U,LDftdu OFFICIAL FROM T!-![REAFTEFi ice; ilillf !f dl r A CORRECTION OF ERRORS IN Pi.ANS, CONS RUCTiON OR VIOL4,110NS OF THIS CODE / / f PERMIT #� _. 0 It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. F_ a 0 z w J U uo z _O cn LO I— > z w w or, 0 U U) n. 0 Cr) cn a� 0 c 0 L co _J n n N CD C1 a J LL Z in E O o Cp U N (D d (A I� o rn o �Lz LU Za �,� � �Q) 3� a) :3 W -0 0 E (n • W o U a W cn L �a J U �- in — cc O o �Z CDo M c a, U a' L aa- Fn N rn (1)K E L O cV Z E Ur`"� CU V)�� On O a Z " o = 0 X T J d LLi PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG COVER SHEET CODE INFORMATION SHEET NO. G1.0 EXIT #2 rnr,- I (IyE�GRESS PLANSLE: 3/16"=1'-0" MEANS OF EGRESS ELEMENT REQUIRED NOTES PROVIDED DOORS 0.2" PER OCCUPANT FOR 36" MINIMUM (NON SPRINKLER) 1140" EACH MEANS 44" MIN AT STOCKROOM AISLE OF EGRESS 7.4" TRAVEL DISTANCE 250 FT MAX (SPRINKLER) RE: TRAVEL DISTANCE TOTAL EXITS 2 EXITS 1-500 OCCUPANTS = 2 EXITS 2 OCCUPANT LOAD ATTRIBUTED TO EXIT MINIMUM CALCULATED —i REQUIRED OPENING WIDTH PLAN LEGEND i� -♦ — — -+ I TRAVEL ROUTE FROM SPACE TO EXIT z I EXIT DOOR �— WIDTH PER OCCUPANT LOAD FACTOR PROVIDED CLEAR OPENING WIDTH MAXIMUM CAPACITY OCCUPANCY TABLE OCCUPANCY S.F. TYPE S.F. PER PERSON S.F. UNIT BUSINESS 100 GROSS MERCANTILE 60 GROSS STORAGE 300 GROSS UNOCCUPIED 0 1. VERIFY EXISTING/INSTALL NEW TACTILE EXIT SIGNAGE AS REQ'D BY CODE: G1.2 FOR MOUNTING HEIGHTS 2. VERIFY EXISTING/INSTALL NEW ADA EXIT ROUTE SIGNAGE AS REQ'D BY LOCAL CODE. RE: 2/G1.2 3. VERIFY EXISTING/INSTALL NEW ADA ACCESSIBILITY SIGNAGE AS REQ'D BY LOCAL CODE. RE: 2/G1.2 4. G.C. TO ACQUIRE FIRE EXTINGUISHERS FROM DTLR'S VENDOR. MINIMUM REQUIREMENT IS 1-TYPE 3A: 40B: C (5LBS) PER 75'-0" OF TRAVEL OR 1 PER 3,000 S.F. OF BUILDING AREA. WHEN MOUNTING ADJACENT TO DOOR OPENING, MAINTAIN 12" CLEAR TO DOOR OPENING FOR ADA COMPLIANCE. PREFERRED LOCATIONS SHOWN, FINAL LOCATION, MOUNTING HEIGHT AND QUANTITY BY FIRE INSPECTOR. G.C. TO VERIFY FIRE MARSHALL REQUIREMENTS FOR INSPECTION AND TAGGING. G.C. TO PROVIDE INSPECTION AND TAG IF NECESSARY. 5. EXISTING SECURITY GRILLE TO BE OPENED AT ALL TIMES WHILE SPACE IS OCCUPIED. It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. H Q IL 1-- z W J U 6-5 (n z O_ N � f- z w w 0 O U W n (n fn O C N C 0 In 0 —1 AT 1 ` N In C� 0, J U. Z In E 0 0 C0 U d �LL M 0 0)0 I�rn �L z w N rn OW ��' WC ~U J a LL con WV > 03 ao �3 O o 3 �Z 0 d- C,4 W U� 11 N V rn �� ( lj Z E or,PO 3 Cc0 CIno No E Z In r cc 1: J 3 a U- PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG EGRESS/LIFE SAFETY PLAN SHEET NO. G1.1 12" MIN. OF P40 LETTERS AND NUMBERS: MOUNTED SIGNAGE FIN. FLOOR ' PULL SIDE PROVIDE THIS COMPRESSED CARPET 1/4' MAX. Co� ADDITIONAL SPACE IF 1. LETTERS AND NUMERALS SHALL BE RAISED 1/32' (0.8 MM) MINIMUM, A. DOOR MOUNTED SIGNAGE: X � BELOW THRESHOLD LEVEL 48" THE DOOR HAS BOTH ? UPPERCASE, SANS -SERIF OR SIMPLE SERIF AND SHALL BE ACCOMPANIED 2 W z 24" A LATCH AND A NTH GRADE 2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8' 1. (UNISEX) _12' DIAMETER CIRCLE 1/4• THICK WITH 1 /4 " N = E E � f 4 _ (16 MM) HEIGHT, BUT NO HIGHER THAN 2" (50 MM) PICTOGRAMS SHALL BE THICK TRIANGLE SUPERIMPOSED WITHIN CIRCLE TERI CLOSER � ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY a t t� BELOW THE PICTOGRAM. THE BORDER DIMENSIONS OF THE PICTOGRAM O 18 SHALL BE 6' (152 MM) MINIMUM IN HEIGHT. (ADAAG SEC. 4.30.4) 2. SIGNS ARE CENTERED ON THE DOOR 60• FROM THE TRANgITION BETWEEN FLOOR FINISHES t0 FLOOR. A NTERI R INTERNATIONAL SYMBOLS FOR 4. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH -TO -HEIGHT ACCESSIBILITY RATIO BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH -TO -HEIGHT RATIO R. WALL MOUNTED SIGNS X Z Z BETWEEN 1:5 AND 1:10. (ADAAG SEC. 4.30.2) 2 � " ' Z_ 1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY IS 201 PICTOGRAM TO COMPLY INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE 2 i.� in yylTy{ 703 g 5. THE CHARACTERS AND BACKGROUND OF SIGNS SHALL BE EGGSHELL, MATTE, OF THE DOOR. THE BORDER DIMENSION SHALL BE A 1 48""° OR OTHER NON -GLARE FINISH. CHARACTERS AND SYMBOLS SHALL Z „ " z SYMBOL OF ACCESSIBILITY MINIMUM OF 6' IN HEIGHT. NOTE: IF NO WALL SPACE IS 00 12 0o CONTRAST WITH THEIR BACKGROUND -EITHER LIGHT CHARACTERS ON � It 5 TO COMPLY WITH 703.7 AVAILABLE, SIGN IS TO BE PLACED ON THE NEAREST g 12" 1 N. d IN. = ( DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. ADJACENT WALL, PREFERABLY ON RIGHT. _ HIGH FORWARD REACH LIMIT �o TEXT NOT IN PICTOGRAM (ADAAG SEC. 4.30.5) FlED (5/6' TO 2' TALL) X DOOR THRESHOLD a 00 2. VERBAL DESCRIPTION AS TO REST ROOM USAGE (I.E. Q � 18" WOMEN 6. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO MEN'S REST ROOM) IS TO BE PLACED DIRECTLY BELOW (X) O W THE VIEWING DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM THE SYMBOL OF ACCESSIBILITY. 2 IN. t- < GRADE 2 BRAILLE HEIGHT IS MEASURED USING AN UPPER CASE X. LOWER CASE CHARACTERS a 1 PUSH SIDE o = ARE PERMITTED. (ADAAG SEC. 4.30.3) 3. FLOOR. ARE CENTERED ON THE WALL 60" FROM THE 7. BRAILLE SHALL BE CONTRACTED (GRADE 2) BRAILLE AND SHALL COMPLY iv PROVIDE THIS WITH SECTION 703.4. (ICC/ANSI SEC. 703.4.1) 4. MOUNTING LOCATION ALLOWS A PERSON TO APPROACH (X) ADDITIONAL SPACE IF REOLNRED ADA SIGNAGE WITHIN 3' OF THE SIGN WITHOUT ENCOUNTERING 0 THE DOOR HAS BOTH WALL--SIGNAGE (TYP.) 8. BRAILLE SHALL BE BELOW THE CORRESPONDING TEXT. IF TEXT IS PROTRUDING OBJECTS OR STANDING WITHIN THE SWING 77 A LATCH AND A TWO HINGED TWO HINGED MULTILINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. BRAILLE OF A DOOR' DOORS IN SERIES DOORS IN SERIES SHALL BE SEPARATED 3/8' (9.5 MM MIN. FROM ANY OTHER TACTILE X CLOSER CHARACTERS AND 3/8" (9.5 MM) MIN. FROM RAISED BORDERS AND �a FRONT APPROACH DECORATIVE ELEMENTS. BRAILLE PROVIDED ON ELEVATOR CAR CONTROLS Ail SHALL BE SEPARATED 3/16'_ (4.8 MM) MIN. EITHER DIRECTLY BELOW OR (Z) It is a violation of the law for ® ADJACENT TO THE CORRESPONDING RAISED CHARACTERS OR SYMBOLS. any person, unless acting under pi (ICC/ANSI SEC. 703.4.4) (Z) �" the direction of a licensed LEVEL CHANGES SIGN LOCATIONS: NOTES: 48" Architect,veo,to a9teereano item in Surve r 1. 1/2" MAXIMUM TOTAL HEIGHT WITH 1/4" MAXIMUM VERTICAL any way. Plans, maps, 9. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY CHANGE AT EDGE. specifications, studies, and PERSONS WITH DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR NOTES: reports not containing a red ink „ GENERAL RESTROOM SIGNAGE LEADING TO AN ACCESSIBLE ROUTE OF TRAVEL SHALL BE IDENTIFIED 2. 1:2 SLOPED BEVEL REQUIRED IF LEVEL CHANGE IS OVER seal imprint on the cover sheet 18 WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF ACCESSIBILITY 1/4' VERTICAL 1. X SHALL BE S 25 INCHES; Z SHALL BE 2 X. accompanied by an original signature by the licensed MI AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE 2. WHEN X S 20 INCHES, THEN Y SHALL BE 48 INCHES MAXIMUM. professional may have been TO PERSONS ALONG APPROACHING PEDESTRIAN WAYS. ICC BC SEC. 1110 3. LEVEL CHANGES OF MORE THAN 1/2" MUST BE RAMPED AND P y PULL SIDE PULL SIDE ( ) COMPLY WITH RAMP REQUIREMENTS. fraudulently altered and shall Z Z � 3. WHEN X IS > 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. not be considered an original z 10. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, copy. Copyright Protected 2018, SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE MAXIMUM FORWARD REACH OVER AN OBSTRUCTKN Larson Design Group. 10 Z " " OF THE DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF PROVIDE TACTILE THRESHOLDS + 24 MI 36 MIN.: THE DOOR, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACE ON SIGNAGE AS PER ANSI lul :2ItcoTHE NEAREST ADJACENT WALL. MOUNTING HEIGHT SHALL BE 60" (1525 MM) CODE SECTION 703 LEVEL CHANGES ABOVE THE FINISH FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING 00 LOCATION FOR SUCH SIGNAGE SHALL BE So THAT A PERSON MAY %INTERNATIONAL INTERNATONAL APPROACH WITHIN 3• (76 MM)OF THE SIGNAGE WITHOUT ENCOUNTERING a SCALE: NTS PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. a TDD SYMBOL SYMBOL OF (ADAAG SEC. 4.30.6) `� X ACCESS FOR :E0 ACCESSIBLE _ HEARING IMPAIRED 11. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL Q- es 4" MAX WIDTH ANY AMOUNT 18 PUSH SIDE PUSH SIDE g o� MI _ _ ARE REQUIRED. (ICC/IBC SEC. 1110) "MI .r 12. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES LLq 4 `Ed FOR PUBLIC USE SHALL HAVE INFORMATION POSTED IN THE LOBBY AS M PART OF THE BUILDING DIRECTORY. 30" INTERNATIONAL SYMBOL OF ACCESSIBILITY: Q * 48" MIN. IF DOOR HAS 54" MIN. 13. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES. 14. WHITE FIGURE ON BLUE BACKGROUND, COLOR # 15090 ON CLEAR FLOOR SPACE HIGH AND LOW BOTH A LATCH AND A _ �i PARALLLIMITS EL APPROACH SIDE REACH FEDERAL STANDARD # 595A. N CLOSER 15. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL N DOORS AT PROPOR noNs FOR > > \ \ zo RAISED INTERNATIONAL SYMBOLS FOR DESIGNS AND COLORS MAY BE APPROVED. OPPOSITE WALLS LATCH APPROACH HINC;� APPROACH Z z FIG (A) FIG (B) >1 DMIN. " ACCESSIBILITY BRAILLE: (ICC/ANSI TABLE 703.4.3) 24' MAX. 30" 1MAX.30" lN- S 16 DOTS TO BE 0.09" (2.3 MM) TO 0.1- (1.5 MM) ON CENTER IN EACH CELL = o 9" 9" 17. 0.241• (6.1 MM) TO 0.3" (7.6 MM) SPACE BETWEEN CELLS HORIZONTALLY. 'a w 0A, QUIRED DOOR CLEARANCES 18. 0.395" (10.0 MM) TO 0.4" (10.2 MM) SPACE BETWEEN CELLS HORIZONTALLY. POST Z EXITROUTE Z TO 2 FIELD T4LL) 5/6• 19' DOTS RAISED 0.025" (O.6 MM) TO 0.037" (0.9 MM) ABOVE BACKGROUND. UOR LATCH SIDE Q Q 0 W LE: NTS EXIT 20. DOTS BASE DIAMETER TO BE 0.059' (1.5 MM) TO 0.063" (1.6 MM). TACTILE SIGNAGE MOUNTING = HEIGHTS ato a ':}f GRADE 2 BRAILLE = X e X V) e a Q r TACTILE SIGNAGE + SYMBOLS CANE RANGE 12" MAX CANE RANGE a . 1 1/4' MI n SIDE REACH OVER AN OBSTRUCTION 1 /2• MA Gl­_ N (1 1/2 SCALE: NTS FIG (C) FIG (D) iz o KING, TYP. FORCALL GRAB BAR U LOCATION �4' MIN DIA (!��SCA_LE: PROTRUDING OBJECTS 5 REACH REQUIREMENTSow I- � 2" MAX DIA o �0 WALL ClRCU_AR 0 O 60" 36" * 56" AT WALL -HUNG TOILETS MINIMUM 6" TOE KICK 4'-0" DRINKING FOUNTAIN NOTES FOR LOW HARDWARE DOORS Z DRINKING FOUNTAIN: HARDWARE. ENTRANCES. THRESHOLDS.Q. SPACE (TYP) 15" 15' HAND ACTIVATED DOOR OPENING HARDWARE IS ALL PRIMARY ENTRANCES TO BUILDINGS AND THRESHOLDS ARE REQUIRED TO BE NO MORE o VERIFY KNEE &TOE A. THE SPOUT SHALL PROVIDE A FLOW OF REQUIRED TO BE CENTERED BETWEEN 34 AND 44 INCHES FACILITIES ARE REQUIRED TO BE MADE ACCESSIBLE. A THAN 1/2 INCH HIGH. BEVEL OR SLOPE THE EXPOSED EDGE WATER AT LEAST 4" O VERIFY KNEE &TOE CLEARANCES WITH HIGH SO AS TO HIGH. LATCHING AND LOCKING DOORS THAT ARE HAND PRIMARY ENTRANCE IS DEFINED AS "...ANY ENTRANCE TO A AT AN ANGLE NOT EXCEEDING 45 DEGREES SO THAT NO c ALT DOOR CLEARANCES WITH SPECIFIED FIXTURE b oACTIVATED AND WHICH ARE IN A PATH OF TRAVEL HAVE TO FACILITY WHICH HAS A SUBSTANTIAL FLOW OF PEDESTRIANS " LOCATION � SPECIFIED FIXTURE I fcus ALLOW THE INSERTION OF A CUP OR SINGLE VERTICAL CHANGE OF ELEVATION EXCEEDS 1/4 INCH. 'Rn RE: MECH BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE TO ANY SPECIFIC MAJOR FUNCTION OF THE FACILITY. RE: MECH NGLASS UNDER THE FLOW OF WATER. 1. EXIT DOORS, TOILET ROOM AND CHANGING ROOM DOOR TO b HIG HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, REVOLVING DOORS CAN NOT BE USED AS A REQUIRED z_ z_ z 00 _ OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE ENTRANCE FOR THE HANDICAPPED. RECESSED DOORMATS ARE BE OPENABLE FROM INSIDE WITHOUT SPECIAL KNOWLEDGE, 0 * NO FIXTURE * ' Z z 30 x48 ao B. CONTROLS SHALL BE FRONT MOUNTED WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING REQUIRED TO BE ANCHORED TO PREVENT INTERFERENCE WITH FORCE OR NEED OF KEY. vOi MAY OVERLAP CLEAR `� OR SIDE MOUNTED NEAR THE FRONT HARDWARE. LOCKED EXIT DOORS ARE REQUIRED TO OPERATE WHEELCHAIR TRAFFIC. 2. SEE SPECIFICATION SHEET FOR RESPONSIBILITIES. CLEARANCE FLOOR EDGE. SPOUTS SHALL BE NO HIGHER AS DESCRIBED ABOVE IN THE DIRECTION OF EGRESS. DOOR WIDTHS AND HEIGHTS. x �30" „ AREA THAN 36" MEASURED FROM THE FLOOR CLOSERS. REQUIRED EXIT DOORWAYS ARE 3• ALL HARDWARE TO BE LEVER TYPE. 60" - < _ MIN" IMUM' MINIMU OR GROUND SURFACES TO THE SPOUT THE MAXIMUM EFFORT TO OPERATE DOORS CANNOT REQUIRED TO HAVE A CLEAR OPENING NOT LESS THAN 32 ENTRANCE SIGNS. OUTLET. EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS INCHES WIDE. FOR HINGED DOORS, THE OPENING IS ALL BUILDINGS ENTRANCES THAT ARE MINIMUM i�l Z - iv Z FOR INTERIOR DOORS. REQUIRED FIRE DOORS MAY REQUIRED MEASURED WITH THE DOOR AT A 90 DEGREE ANGLE FROM ACCESSIBLE TO AND USABLE BY PHYSICALLY HANDICAPPED z z UP TO 15 POUNDS PRESSURE. THE PRESSURE IS TO BE ITS CLOSED POSITION. AT LEAST ONE OF A PAIR OF DOORS, PERSONS SHALL BE IDENTIFIED WITH AT LEAST ONE n g g C. WALL AND POST MOUNTED MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT THE INCLUDING AUTOMATIC DOORS, HAS TO PROVIDE THE 32 INCH STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, co CANTILEVERED UNITS SHALL HAVE A CENTER PLANE OF SLIDING OR FOLDING DOORS. CLEAR OPENING. DOOR HEIGHTS ARE REQUIRED TO BE A AS REQUIRED TO BE VISIBLE TO PERSONS ALONG LAVATORY DRINKING CLEAR KNEE SPACE BETWEEN THE -� z n E URINAL COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MINIMUM OF 80 INCHES. APPROACHING PEDESTRIAN WAYS. lL 0 0 WATER CLOSET WATER CLOSET AMBULATORY CLEARANCE FOUNTAIN PLAN BOTTOM OF THE APRON AND THE MAY BE UTILIZED TO MEET THE REQUIREMENTS. IF A DOOR W co 0 CLEARANCE STALL CLEARANCE STALL CLEARANCE FLOOR OR GROUND AT LEAST 27" HIGH, HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER ;n � a 39"-41" 36" 30" WIDE, AND 17-19" DEEP. SUCH SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF U) 0 aa) N 0 •� 15" 15" UNITS SHALL HAVE A MINIMUM CLEAR 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO LL rn O n 0) 24 �> MOVE TO A POINT 3 INCHES (75 mm) FROM THE LATCH, j[ Z tL (V C FLOOR SPACE 30 X 48 TO ALLOW A �� .-. DRINKING MEASURED TO THE LEADING EDGE OF THE DOOR. Z •� 12" 42' 0 FOUNTAIN PERSON IN A WHEEL- CHAIR TO N Go 0 q PARTITION w%o < wo Q Q APPROACH THE UNIT FACING FORWARD. 2 to wT x :D � VC x Q o ran x Q o o �' D. THE FOLLOWING KNEE CLEARANCE IS O J Q it N CO CO _ "MIN Q Tt F W Q z � o� z U) 15' z - 0 REQUIRED UNDERNEATH THE FOUNTAIN: �� W Ir ■ .? � - o > o > o MIN• M 0- 27" MIN. FROM THE FLOOR TO THE J V !10 3 x 0 m ~ 0° I- - ~ O UNDERSIDE OF THE FOUNTAIN WHICH LEVER 34" TO Y o M ►`D M 1� g 0 W O W o r` f- 44" A.F.F. I EXTENDS 8 MIN. MEASURED FROM THE �1J a o 18" ? 15" `�I � 7 "Ld FRONT EDGE UNDERNEATH THE JCL 0 MIN. FOUNTAIN BACK TOWARDS, THE WALL; C °' Q rn " LEVER OR U SHAPED W 0 N LAVATORIES DRINKING FOUNTAIN IF A MIN. 9" OF TOE CLEARANCE IS HANDLE MOUNTED AT U .N 0 a r j WATER CLOSETS ELEVATION PROVIDED, A MAX. OF 6 OF THE 48 34 TO 48 AFF Z (D E o o M WATER CLOSET STALL URINALS TOE CLEARANCE OF CLEAR FLOOR SPACE REQUIRED AT E 0 r, o THE FIXTURE MAY EXTEND INTO THE CO v 0 uI r- TOE SPACE. (10" MIN. BOTTOM � ` 0 o z In TOILET ROOM FIXTURES HEIGHTS + CLEARANCES 9 RAIL J = a 2'-8" CLEAR DOOR HARDWARE DETAIL EQ. EQ. (:�) 01 SCALE: NTS z �16" 719-91 LILJ O X N X X 0 J m-w QZ 0O Ito< � O_ _ m -H - N -00 Z x t` Q LL _ Ln o _ _ - Q \ 0 _ _ - JOf 00 cCD r�Li p T �O O�"ON 0 �od O �� M TOILET SEAT SURFACE SANIIITACOAT SOAP NAPKIN BABY TOILET PULLS at SURFACE CHILD MIRROR @DISPENSER COVER O OWE ED PAPEROHOOK ODISPENSER OF DISPOSAL OG CHANGING OTISSUE OI OMOUNTED FIRE PROTECTION ACCESSIBILITY REQUIREMENTSTOILET PROJECT No. 11979-002 (WOMEN'S ONLY) STATION DISPENSER PARTITIONS EXTINGUISHER SEAT DISPENSER A. ALL CONSTRUCTION SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE DRAWN BY EBG 2010 2010 2010 2010 2010 2010 ADA 2010 STANDARDS 305 2010 ADA STANDARDS 2010 STANDARDS 2010 STANDARDS 308 DESIGN GUIDELINES ESTABLISHED BY THE 2010 ADA STANDARDS FOR STANDARDS STANDARDS STANDARDS STANDARDS STANDARDS STANDARDS OF & 308 OF ACCESSIBLE DESIGN, 404.2.7 & 604.8.2.2 ACCESSIBLE DESIGN (2010 STANDARDS) . 603.3 308 213.3.7, 603.4 308 ACCESSIBLE DESIGN, SEE SECTIONS 604.7 & COORDINATE W APPv'D BY 308 HEIGHT OF SHELF IN / B. UTILIZE EXTREME CARE TO ENSURE THAT ALL TOLERANCES, DIMENSIONS, AND RJG & 308 SEE SECTIONS 604.7 DOWN POSITION 34" 609.3 PARTITION MFG CLEARANCES ARE CONSTRUCTED ACCURATELY. _ ACCESSORY MOUNTING DIAGRAMS & 609.3 MAX AFF ADA ACCESSIBILITY C. TAKE ANY AND ALL ACTIONS NECESSARY TO CORRECT CONDITIONS WHICH ARE 7 SCALE: 1/4"=1'-0" IN THE OPINION OF THE STATE ACCESSIBILITY INSPECTOR IN VIOLATION OF NOTE: NOT ALL HANDICAP COMPONENTS MAY BE DIAGRAMS GUIDELINES AS THE DIRECT & SOLE RESULT OF DEVIATIONS FROM THE USED IN THIS PROJECT. THIS SHEET IS SHEET NO. CONSTRUCTION DOCUMENTS OR INADEQUATE CONSTRUCTION CONTROL &, OR, PROVIDED FOR GENERAL REFERENCE ONLY G 1.2 TOLERANCES. ABBREVIATIONS SYMBOLS A C F K P ® AT C TO C CENTER TO CENTER FA FIRE ALARM K KIP (THOUSAND POUNDS) / PER (BETWEEN WORDS) UGND & AND CANTIL CANTILEVER FB FLAT BAR KB KFT KNEE BRACE THOUSAND FT POUNDS P PAR PUMP PARALLELK UH A AMPERE, COMPRESSED AIR CAP CAPACITY FC BR FACE BRICK KLF KIPS PER LINEAR FOOT PB PUSH BUTTON UL A/C AIR CONDITIONING CB CATCH BASIN FD FLOOR DRAIN KO KNOCK OUT PBO PROVIDED BY OTHERS UN AB ANCHOR BOLT CBORE COUNTERBORE FDC FIRE DEPARTMENT KPL KICK PLATE PC PLUMBING CONTRACTOR UNC ABAN ABANDON ( ) ED CC CUBIC CENTIMETER CONNECTION KSI KIPS PER SQUARE INCH PIECE UNEX ABT ABOUT CCTV CLOSED CIRCUIT TELEVISION FDMPR FIRE DAMPER KV KILOVOLT PCC PRECAST CONCRETE UNFIT ABUT ABUTMENT CLSM CONTROLLED LOW STRENGTH FDN FOUNDATION KVA KILOVOLT -AMPERE PCF POUNDS PER CUBIC FOOT UNF ABV ABOVE CEM MATERIAL CEMENT FE FEC FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET KW KILOVAR PEC PHOTO ELECTRIC CELL UNIV UNO AC ALTERNATING CURRENT CER CERAMIC FF EL FINISHED FLOOR ELEVATION KW KILOWATT PERF PERFORATED UR ACC ACI ACCESSIBLE AMERICAN CONCRETE INSTITUTE CERTS CERTIFICATES FGL FIBERGLASS PERP PI PERPENDICULAR PHASE ACM ALUMINUM COMPOSITE MATERIAL CFM CUBIC FOOT (FEET) PER FIN FINISHED L PIBO PROVIDED AND INSTALLED ACS ACCESS MINUTE FIN FLR FINISHED FLOOR — BY OTHERS ACT ACOUSTICAL CEILING TILE CFS CUBIC FOOT FEET PER ( ) FL FLOOR LINE L LEFT PL PLATE, PROPERTY LINE ADDL ADDITIONAL SECOND FLA FULL LOAD AMPS LAD LADDER PLAM PLASTIC LAMINATE V ADDM ADDENDUM CG CENTER OF GRAVITY FLG FLANGE, FLOORING LAM LAMINATE PLF POUNDS PER LINEAR FOOT VAR ADH ADHESIVE CHFR CHAMFER FLJ FLOOR JOIST LAV LAVATORY PL GL PLATE GLASS ADJ ADJACENT, ADJUSTABLE CHKD CHECKED, CHECKERED FLR FLOOR LBS POUNDS P PLYWOOD VAV AFF ABOVE FINISHED FLOOR CLG HT CEILING HEIGHT FLR PL FLOOR PLATE LF LINEAR FEET PMF PRE -MOLDED FILLER, VB AFG ABOVE FINISHED GRADE CI CAST IRON FOC FACE OF CONCRETE LG LENGTH PROBABLE MAXIMUM FLOOD AGGR AGGREGATE CIP CAST -IN -PLACE, CAST IRON FOF FACE OF FINISH LH LEFT HAND PNL PANEL AHD AHEAD PIPE FOM FACE OF MASONRY LL LIVE LOAD PR PAIR VCB AHU AIR HANDLING UNIT CJ CONSTRUCTION JOINT FOS FACE OF STUDS LLBB LONG LEG BACK TO BACK PREFIN PSHED AISC AMERICAN INSTITUTE OF STEEL CL CENTER LINE FPM FOOT (FEET) PER MINUTE LLH LONG LEG HORIZONTAL PSI POOUNDUND S PER SQUARE FOOT VCT CONSTRUCTION CLG CEILING FPS FOOT (FEET) PER SECOND LLV LONG LEG VERTICAL PSI POUNDS PER SQUARE INCH VEL VEST ALT ALTERNATE CLJ CONTROL JOINT FR FRAME LONG LONGITUDE, LONGITUDINAL PSIA POUNDS PER SQUARE INCH VEST ALUM ALUMINUM CLO CLOSET FRP FIBER REINFORCED PLASTIC LPCR LOW PRESSURE CONDENSATE RETURN ABSOLUTE AMER STD AMERICAN STANDARD CLR CLEAR, CLEARANCE FS FAR SIDE, FEDERAL LIPS LOW PRESSURE STEAM PSIG POUNDS PER SQUARE INCH VIF ANC ANCHOR, ANCHORAGE CLWG CLEAR WIRE GLASS SPECIFICATION LPT LOW POINT GAGE VIN ANOD ANODIZED CM CENTIMETER FT FOOT FEET ) LS LUMP SUM PT PAINT, PRESSURE TREATED VSD VTR APPD APPROVED CMP CORRUGATED METAL PIPE FTG FOOTING LVL LAMINATED VENEER LUMBER, LEVEL PTD PAINTED APPROX APPROXIMATE CMU CONCRETE MASONRY UNIT FVNR FULL VOLTAGE LVR LOUVER PTN PARTITION APPV APPROVE CO CLEAR OPENING NON -REVERSING LWC LIGHTWEIGHT CONCRETE PTW PRESSURE TREATED WOOD ARCH ARCHITECT, ARCHITECTURAL COL COLUMN FVR FULL VOLTAGE REVERSING LWIC LIGHTWEIGHT INSULATING CONCRETE PVC POINT OF VERTICAL ARR ARRANGEMENT CONC CONCRETE CURVE, POLYVINYL CHLORIDE W ASAP AS SOON AS POSSIBLE CONF CONFERENCE ASSY ASSEMBLY CONN CONNECTION, CONNECTOR W/ ASTM AMERICAN SOCIETY OF TESTING CONSTR CONSTRUCTION G M O W/0 AND MATERIALS CONT CONTINUE, CONTINUATION, WB AUTO AUTOMATIC CONTINUOUS G GIRDER, GROUND, GROUND MA MAINTENANCE QA QUALITY ASSURANCE WBL AUX AUXILIARY COORD COORDINATE WIRE, NATURAL GAS MAS MASONRY QC QUALITY CONTROL WC AVG AVERAGE CORP CORPORATE, CORPORATION GA GAUGE OR GAGE MATL MATERIAL QT QUARRY TILE, QUART WD AWG AMERICAN WIRE GAGE CORR CORRIDOR, CORRUGATED GAB GRADED AGGREGATE BASE MAX MAXIMUM QTY QUANTITY WF AWS AMERICAN WELDING SOCIETY CPT CARPET WG AZ AZIMUTH CRS COLD ROLLED STEEL GALV GALVANIZED MBTUH THOUSAND BRITISH THERMAL WH CS CARBON STEEL GB GRAB BAR UNITS PER HOUR WHM CSK COUNTERSINK GC GENERAL CONTRACTOR MC MECHANICAL CONTRACTOR R WL B CSMT CASEMENT GF GROUND FACE MOMENT CONNECTION R RADIUS, RISER WO CTB CERAMIC TILE BASE GFCI GFI / GROUND FAULT CIRCUIT MCB MAIN CIRCUIT BREAKER B/B BACK TO BACK CTF CERAMIC TILE FLOOR INTERRUPTION MCC MOTOR CONTROL CENTER RA RC RETURN AIR REINFORCED CONCRETE WP BC BOLT CIRCLE CTJ CONTRACTION JOINT GL GIRT LINE, GLASS, MECH MECHANICAL RD ROOF DRAIN WSCT BD BOARD CTR CENTER GROUND LEVEL MED MEDIUM RE: REFER TO WU BFILL BACK FILL CTW CERAMIC TILE WAINSCOT GOD GROUND MEMB MEMBRANE RECPT RECEPTACLE WWR BITUM BITUMINOUS CTWALK CATWALK GOVT GPH GOVERNMENT GALLONS PER HOUR MEZZ MFD MEZZANINE MANUFACTURED REINF REINFORCING BK BACK CU CU IN COPPER CUBIC INCH GPM GALLONS PER MINUTE MFR MANUFACTURER REM REMOVABLE BL BASE LINE, BUILDING LINE CU FT CUBIC FEET GPS GALLONS PER SECOND MH MANHOLE REQD REQUIRED BLDG BLK BUILDING BLOCK CU M CUBIC METER GR GRADE MI MALLEABLE IRON MILE REV RFG REVISION ROOFING X BLKG BLOCKING CU MM CUBIC MILLIMETER GR BM GRADE BEAM MIL ONE THOUSANDTH INCH RH RIGHT HAND A BM BEAM, BENCH MARK CUB CUBICLE GRTG GRATING MIN MINIMUM RM ROOM XMFR BOC BOTTOM OF CURB CU YD CUBIC YARD GT GIRDER TRUSS, GROUT MISC MISCELLANEOUS RO ROUGH OPENING XS BOD BOTTOM OF DUCT CYL CYLINDER GWB GYPSUM WALLBOARD MLDG MOLDING, MOULDING RPM REVOLUTIONS PER MINUTE XXS BOF BOTTOM OF FOOTING GWR GLYCOL WATER RETURN MLO MAIN LUGS ONLY RT RIGHT GWS GLYCOL WATER SUPPLY MM MILLIMETER BOP BOS BOTTOM OF PIPE BOTTOM OF STEEL D MO MASONRY OPENING RTU RWC ROOFTOP UNIT RAINWATER CONDUCTOR MR MOISTURE RESISTANT BOT BOTTOM MTD MOUNTED BOW BP BOTTOM OF WALL BASE PLATE DEEP,DEPTH, PENNY(NAIL) H MTL METAL YD BRCG BRACING DB D B MV MERCURY VAPOR BRG BEARING DBL DOUBLE H HIGH N BRG PL BEARING PLATE DC DDC DIRECT CURRENT DIRECT DIGITAL CONTROL HC HOLLOW CORE S SOUTH BRK BRICK DEG DEGREE HCA HEADED CONCRETE ANCHOR N NORTH (S) SLOPES ZD BRKT BS BRACKET BOTH SIDES DEMO DEMOLISH. DEMOLITION HDR HEADER NA NOT APPLICABLE SC SOLID CORE BSMT BASEMENT DET DETAIL HDW HARDWARE NAAMM NATIONAL ASSOCIATION OF SCHED SCHEDULE BTU BRITISH THERMAL UNIT DF DRINKING FOUNTAIN H HEEXX HARDWOOD HEXAGONAL NATL ARCHITECTURAL METAL MFR. NATIONAL SECT SECTION BTUH BRITISH THERMAL UNIT PER DFT DRY FILM THICKNESS HEX HD HEXAGONAL HEAD NC NORMALLY CLOSED SENS SENSIBLE HOUR DH DOUBLE HUNG FIG HOT GAS, HEAT GAIN, NEC NATIONAL ELECTRICAL SHN SHOWN BTWN BETWEEN DIA DIAMETER MERCURY CODE, NECESSARY SHT SHEET BVL BEVELED DIAG DIAGONAL, DIAGRAM HGR HANGER NEMA NATIONAL ELECTRICAL SHT MTL SHEET METAL BW BOTH WAYS DIFF DIFFERENCE HK HOOK MANUFACTURERS ASSOCIATION SHTHG SHEATHING DIM DIMENSION HM HOLLOW METAL NESC NATIONAL ELEC SAFETY CODE SIM SIMILAR DL DEAD LOAD HORIZ HORIZONTAL NF NEAR FACE SJI STEEL JOIST INSTITUTE DMPR DAMPER HP HORSE POWER NIC NOT IN CONTRACT SLBB SHORT LEG BACK TO DN D DOWN DOMESTIC HPS HIGH PRESSURE SODIUM NO NUMBER BACK DP DEW POINT HPT HIGH POINT NOM NOMINAL SPEC SPECIFICATION) DR DOOR HS HIGH STRENGTH NPT NATIONAL TAPER PIPE (THREAD) SPF SPRUCE -PINE -FIR DS DISCONNECT SWITCH, HSB HIGH STRENGTH BOLT NS NEAR SIDE SQ SQUARE DOWNSPOUT HSS HOLLOW STRUCTURAL SHAPE NTS NOT TO SCALE SQ FT SQUARE FOOT DWG DRAWING HT HVAC HEIGHT HEATING, VENTILATION AND O SQ IN SQUARE INCH AIR CONDITIONING SQ MI SQUARE MILE HVY HEAVY OA OUTSIDE AIR SS SANITARY SEWER E HW HOT WATER OC ON CENTER SST STAINLESS STEEL HWR HOT WATER RETURN OD OUTSIDE DIAMETER STD STL STANDARD STEEL E EAST HWS HOT WATER SUPPLY OF OUTSIDE FACE STIF STIFFENER EA EACH HWY HIGHWAY OFM OUTSIDE FACE OF MASONRY STIR STIRRUP EAT ENTERING AIR TEMPERATURE HZ HERTZ OPH OPPOSITE HAND STOR STORAGE EC ELECTRICAL CONTRACTOR OPNG OPENING STRUCT STRUCTURAL EER ENERGY EFFICIENCY RATIO OPP OPPOSITE SQ YD SQUARE YARD EF EACH FACE OR OUTSIDE RADIUS SYMM SYMMETRICAL EFF EFFICIENCY OSB ORIENTED STRAND BOARD EJ EXPANSION JOINT IBC INTERNATIONAL BUILDING OSHA OCCUPATIONAL SAFETY AND EL EACH LAYER, ELEVATION CODE HEALTH ADMINISTRATION T ELEC ELECTRIC/ELECTRICAL IBO INSTALLED BY OTHERS OVHD OVERHEAD — ELEV ELEVATOR ID INSIDE DIAMETER OWJ OPEN -WEB JOIST EMB EMBANKMENT IE THAT IS OZ OUNCE T TREAD EMBED EMBEDMENT IF INSIDE FACE T&B TOP AND BOTTOM EMER EMERGENCY IJ ISOLATION JOINT T&G TONGUE AND GROOVE EMT ELECTRICAL METALLIC TUBING IN INC INCH INCORPORATED, INCREASE TB TC TOWEL BAR TERRA COTTA, TOP CHORD ENCL ENCLOSURE INCL INCLUDE TEMP TEMPORARY EOD EDGE OF DECK INFO INFORMATION THD THREAD EOS EQ EDGE OF SLAB EQUAL INSUL INSULATE INSULATION THK THICKNESS EQL SP EQUALLY SPACED INTMD INTERMEDIATE THRES THRESHOLD EQUIP EQUIPMENT INT INTERIOR THRU THROUGH ERV ENERGY RECOVERY IPS IRON PIPE SIZE TO TOC TOP OF TOP OF CONCRETE VENTILATOR IR INSIDE RADIUS TOF TOP OF FOOTING ES EACH SIDE, EDGE OF TOG TOP OF GRATING SHOULDER, ELECTROSTATIC TOG TOP OF JOIST ESP EXTERNAL STATIC PRESSURE J TOS TOP OF STEEL EVAP EVAPORATOR — TRS TRUSS EW EWC EACH WAY ELECTRIC WATER COOLER J-BOX JUNCTION BOX TRTD TREATED EXC EXCAVATE JAN CLO JANITOR'S CLOSET TS TUBE STEEL EXP EXPANSION JST JOIST TOD TOP OF DUCT EX EXISTING JT JOINT TOW TOP OF WALL TV TELEVISION EXT EXTERNAL, EXTERIOR TYP TYPICAL EXT GR EXTERIOR GRADE U UNDERGROUND UNIT HEATER UNDERWRITER'S LABORATORIES UNLESS NOTED UNIFIED COARSE THREAD UNEXCAVATED UNFINISHED UNIFIED FINE THREAD UNIVERSAL UNLESS NOTED OTHERWISE URINAL VENT, VOLT, VOLTAGE VARIABLE, VARIATION, VARIES VARIABLE AIR VOLUME BOX VACUUM BREAKER, VINYL BASE VACUUM CIRCUIT BREAKER, VINYL COVER BASE VINYL COMPOSITION TILE VELOCITY VERTICAL VESTIBULE VERIFY IN FIELD VINYL VARIABLE SPEED DRIVE VENT THRU ROOF W WASTE, WATT, WEST, WIDE WITH WITHOUT WET BULB, WOOD BASE WOOD BLOCKING WATER CLOSET WOOD WIDE FLANGE WATER GAUGE, WIRE GUARD WATER HEATER WATT HOUR METER WIND LOAD WALL OPENING, WHERE OCCURS, WORK ORDER WORK POINT WAINSCOT WINDOW UNIT WELDED WIRE REINFORCING X BY (BETWEEN DIMENSIONS) CROSS BRACING TRANSFORMER EXTRA STRING DOUBLE EXTRA STRONG Y YARD Z ZONE DAMPER DRAWING NUMBER _J(0 Ao.0 SHEET NUMBER 0 A0.0 I I I A 1 A0.0 N-0) A0 0 0 0 FIRST FLOOR A0.0 D .0 B 100.00 DETAIL BUILDING SECTION EXTERIOR INTERIOR FLOOR MARKER SECTION MARKER ELEVATION ELEVATION ELEVATION MARKER MARKER MARKER TAG "4 CORRIDOR 001 Di 1 O (A� ❑1 01 1 000 DOOR WINDOW WALL COLUMN EXISTING KEY DEMO REVISION ROOM NAME TAG TAG TYPE TAG GRID TAG COLUMN NOTE KEY NOTE AND NUMBER GRID TAG NOTE OMENOMME IIIIIIIIIIII ACOUSTIC�FINISH WOOD ASPHALT ROOFING INSULATION GRANULAR (LOOSE OR BATT) SUBBASE PLYWOOD CONCRETEBRICK ...... :::::: •. PRECAST) • 'MASONRY CONCRETE • • EARTH OR STEEL CONCRETEBACKFILL WALL LEGEND EXISTING TO REMAIN OR NEW LOW WALL ASSEMBLY NEW STUD WALL ASSEMBLY 111111111111 WALL / SOFFIT ABOVE FIRE RATINGS � ■ � 1-HOUR FIRE RATED ASSEMBLY ■ ■ 2-HOUR FIRE RATED ASSEMBLY ll� ■ ■ ■ 3-HOUR FIRE RATED ASSEMBLY m ■ ■ ■ ■ m 4-HOUR FIRE RATED ASSEMBLY NOTE: NOT ALL ABBREVIATIONS AND SYMBOLS MAY BE USED IN THIS PROJECT. THIS SHEET IS PROVIDED FOR GENERAL REFERENCE ONLY OF Flo 4 It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. V) z O I_ > z w w 0 0 U w W V) LU a 0 a. w U N E2 c0 0 J LL 0 0 cp U 'e) o rn0 Y ►Norn W Q CO . a� a) 3 , w -0 O J 0 L IL En WV 03 �3 =o �c O 3 J W L 0 O ■ 0- '- cv W ° co C ' ¢ rn U .N �0N°' K)� Z 0 0�'? E 3 C 0 a 0 ` o v Z ii coC)= = XX J LL 11 PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG SYMBOLS & ABBREVIATIONS SHEET NO. G2.0 GENERAL NOTES DIVISION I GENERAL REOUIREMENTS/GENERAL CONDITIONS (CONT.) DIVISION V METALS DIVISION VIII DOORS + WINDOWS (CONT.) DIVISION IX FINISHES (CONT.) 1. VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS. BRING ANY DEVIATIONS TO THE I. GUARANTEE: A. METAL STUDS B. ACCESS DOORS: F. VINYL COMPOSITION TILE: ATTENTION OF THE TENANT'S PROJECT MANAGER. 1. A WRITTEN GUARANTEE SHALL BE PROVIDED ON ALL LABOR AND MATERIALS FOR A 1. 20 GA. MINIMUM AT NON -SALES WALLS, AT STOREFRONT OR WALLS WITH DECKS ABOVE. 1. PROVIDE FLUSH TYPE METAL DOORS MIN 16" X 20", OR AS SPECIFIED ON THE 1. REFER TO RESPONSIBILITY SCHEDULE AND FINISH SCHEDULE PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF THE SUBSTANTIAL COMPLETION 2. 25 GA. MINIMUM, AT 16" O.C. MAXIMUM, AT TYPICAL PARTITIONS UNLESS OTHERWISE DRAWINGS, MANUFACTURED FORM # 16 GA. STEEL, COMPLETE WITH FLUSH FLANGE TYPE 2. ALL EDGE CONDITIONS AT TRANSITIONS TO BE FLOATED UP FOR SMOOTH EVEN 2. ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE. CONTRACTOR SHALL FIELD OF THE PROJECT. NOTED. FRAMES MANUFACTURED FROM # 16 GA. STEEL, WITH ANCHORS. TRANSITION. VERIFY ALL DIMENSIONS PRIOR TO COMMENCING THE WORK. FAILURE TO DO SO SHALL PLACE 2. THE TENANT'S REPRESENTATIVES SIGNATURE AND DATE OF ACCEPTANCE IS REQUIRED 3. CONTRACTOR SHALL PROVIDE ALL FASTENERS, SCREWS, BOLTS, CLIPS, ANCHORS, 2. INSTALL ACCESS DOORS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED 3. ALL SUBFLOORS TO BE MOISTURE TESTED AND RESULTS COMPARED TO FULL RESPONSIBILITY FOR ANY ERRORS UPON THE CONTRACTOR. IN ORDER TO ACTIVATE THIS GUARANTEE. THIS GUARANTEE SHALL COVER ALL OF THE ANGLES, BRIDGES, BRACKETS, SLEEVES, ETC. AS REQUIRED. VALVES, AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION AND AS APPROVED BY MANUFACTURERS RECOMMENDED INSTALLATION GUIDELINES. ANY PROBLEMS DUE TO GENERAL AND SUBCONTRACTOR'S WORK. ALL DEFECTS DISCOVERED DURING THIS THE TENANT'S PROJECT MANAGER. MOISTURE TESTING TO BE REPORTED TO TENANT'S REPRESENTATIVE IMMEDIATELY. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL SETBACKS, AND/OR GUARANTEE PERIOD SHALL BE REPAIRED TO THE OWNER AND/OR TENANT'S SATISFACTION B. METAL STANDARDS 3. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN THE SPECIFIED WALL AND 4. 1/8" X 12" X 12" VINYL RESILIENT TILES WITH 4" HIGH X 1/8" THICK, TOP -SET, EASEMENTS, EXISTING UTILITIES, AND ANY UNDERGROUND OR SURFACE STRUCTURE OR AT CONTRACTOR'S EXPENSE AT NO COST TO THE OWNER AND/OR TENANT. 1. FURNISH AND INSTALL PER PLANS AND MANUFACTURER'S RECOMMENDATIONS. CEILING MATERIALS. STRAIGHT VINYL BASE (PRE FORMED CORNERS ARE REQUIRED). SEE FINISH SCHEDULE. CONDITIONS PRIOR TO COMMENCING THE WORK. 4. ACCESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS, CEILING -FLOOR OR 5. FILL ALL CRACKS, JOINTS, ETC., IN SUB -FLOOR WITH CRACK FILLER APPROVED BY J. SUPERVISION: C. STRUCTURAL STEEL, AND/OR HEAVY GAUGE METAL FRAMING CEILING -ROOF ASSEMBLIES SHALL BE UL FIRE RATED LISTED AND LABELED. FLOORING MANUFACTURER, 4. UPON COMPLETION OF THE WORK, PROVIDE A WALL FRAME WITH CLEAR PLEXI FACE OVER 1. PROVIDE A FULL TIME, QUALIFIED SUPERVISOR ON THE JOB SITE. ANY WORK 1. INSTALL FRAMING, CONNECTION PLATES, SCREWS, BOLTS, ETC. AS SHOWN IN PLANS AND 5. FINISH TO MATCH ADJACENT SURFACES. 6. INSTALL ALL MATERIALS WITH WEATHERPROOF TYPE ADHESIVES AS RECOMMENDED BY THE MANAGER'S DESK CONTAINING THE CERTIFICATE OF OCCUPANCY. REQUIRED TO BE COMPLETED DURING NON -BUSINESS HOURS SHALL BE INCLUDED IN THE DETAILS. 6. PROVIDE KEYED LOCK AT ALL PANELS IN COMMON AREAS. FLOORING MANUFACTURER FOR MATERIALS AND SURFACE INVOLVED. 5. SECURE AND PAY FOR ALL PERMITS AND LICENSES NECESSARY FOR THE EXECUTION OF BID. 2. PROVIDE A JOB SITE TELEPHONE AND FAX MACHINE DURING THE CONSTRUCTION D. PROTECTIVE CORNER GUARDS 1. PROVIDE AND INSTALL METAL CORNER GUARDS 2"x2"x42" AT ALL OUTSIDE CORNERS OR ( ) C. STOREFRONT: 1. FURNISH ALL NECESSARY MATERIALS, LABOR AND EQUIPMENT FOR THE COMPLETE G. FIBERGLASS REINFORCED PANELS 1/8-: / THE WORK. PERIOD. NOTIFY TENANT'S REPRESENTATIVE IMMEDIATELY OF TELEPHONE AND FAX AS SPECIFIED IN THE PLANS; SPACKLE AND SAND SMOOTH. INSTALLATION OF FRAMING AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 1. REFER TO RESPONSIBILITY SCHEDULE AND FINISH SCHEDULE. 2. PROVIDE AND INSTALL FIBERGLASS REINFORCED PANELS ON SURFACES AS SHOWN ON 6. SEE RESPONSIBILITY SCHEDULE TO CLARIFY RESPONSIBILITIES FOR SPECIFIED WORK. NUMBERS. 3. COORDINATE AND SCHEDULE ALL NON -BUSINESS HOUR WORK WITH BUILDING E. REVEALS 2. ALL GLASS FRAMING SHALL BE SET IN CORRECT LOCATIONS AS SHOWN IN THE DETAILS AND SHALL BE LEVEL, SQUARE, PLUMB, AND IN ALIGNMENT WITH OTHER WORK PLANS. MANAGER. 1. INSTALL METAL REVEALS; SIZE AND LENGTH AS INDICATED ON PLANS. PROVIDE IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND APPROVED 3. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SPECIFICATIONS BLOCKING OR BACKING AS REQUIRED TO SECURE IN PLACE. SHOP DRAWINGS. H. WALK -OFF MAT: T.B.D. (ROLL -UP TYPE) K. UTILITIES: 1. PROVIDE ALL TEMPORARY UTILITIES (INCLUDING, BUT NOT LIMITED TO, WATER, 2. PAINT OR FINISH PER PLANS. 3. PROTECT STOREFRONT FROM DAMAGE BEFORE, DURING, AND AFTER INSTALLATION. DMSION I GENERAL REOUIREMENTS/GRCONDITIONS ENEAL SEWERAGE, ELECTRICAL POWER, FUEL AND TELEPHONES) AND THE COSTS ASSOCIATED WITH THESE. PROVIDE TENANT'S REPRESENTATIVE WITH ALL UTILITY COMPANY NAMES, F. EXPANSION JOINTS 1. INSTALL PER PLANS AND MANUFACTURER'S RECOMMENDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR A COMPLETE AND OPERATIONAL TENANT SPACE DIVISION IX FINISHES INCLUDING, BUT NOT LIMITED TO ALL FINISHES, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE NUMBERS, CONTACTS AND ACCOUNT NUMBERS (TENANT WILL TRANSFER ACCOUNTS TO 2. USG 093 FOR CEILINGS AND WALLS, AS MAY BE INDICATED IN THE DRAWINGS. PROTECTION. THEIR NAME AT TURNOVER).AL 3. 100 OR 200 SERIES AS REQUIRED FOR APPLICATION (OPTIONAL 1" DEPTH) WITH DIVISION X SPECIALTIES A. GYPSUM DRYWALL A. LAVATORY FIXTURES: ELASTOMERIC FILLER TO MATCH FINISH AS MANUFACTURED BY CONSPEC SYSTEMS INC., A. COORDINATION: L. TRASH REMOVAL: 877-CONSPEC. 1. INSTALL ALL GYPSUM DRYWALL SYSTEMS COMPLETE WITH PARTITION FRAMING, CEILING 1. REFER TO MECHANICAL DRAWINGS. 1. OBTAIN A COPY OF THE TENANT CONTRACTOR GUIDELINES HANDBOOK AND COMPLY WITH 1. PROVIDE FOR DAILY REMOVAL OF ALL TRASH, RUBBISH AND SURPLUS MATERIALS SUSPENSION SYSTEMS, AND RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON THE REQUIREMENTS. NOTE IN PARTICULAR THE INSURANCE REQUIREMENTS, UTILITY LOCATIONS, RESULTING FROM CONSTRUCTION, FIXTURING, AND MERCHANDISING OF THE DEMISED G. SUSPENSION SYSTEM DRAWINGS AND AS SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURER'S B. LAVATORY ACCESSORIES: CONSTRUCTION PROCEDURES, TEMPORARY BARRICADE WALLS, CONSTRUCTION MATERIAL PREMISES. 1. PROVIDE AND INSTALL UNISTRUT SPACE FRAME GRID SYSTEM PER MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. 1. REFER TO ARCHITECTURAL DRAWINGS. STORAGE, HAUL OFF AND PERMIT INFORMATION. SPECIFICATIONS AS REQUIRED FOR LIGHTING, CEILING ACCESSORIES OR MECHANICAL 2. GYPSUM DRYWALL: U.S. GYPSUM 5/8" THICK FIRE CODE SHEETROCK (TYPE "X") PANELS 2. INSTALL IN -WALL BLOCKING AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. 2. COORDINATE WORK WITH WORK OF OTHER TRADES, THE LANDLORD'S FORCES, OTHER M. CLEAN UP AT TURNOVER: SYSTEMS SUSPENSION. OF STANDARD QUALITY OR EQUAL. 3. INSTALL ACCESSORIES OVER FINISHED WALL SURFACE. TENANT CONTRACTORS, AND TENANT STORE OPERATIONS IN ORDER TO AVOID CONFLICTS AND 1. PROVIDE A PROFESSIONAL CLEANING SERVICE FOR ALL AREAS OF THE STORE AT THE 2. SUPPORT FROM STRUCTURE WITH THREADED RODS AND NUTS AS REQUIRED OR DETAILED. 3. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE. EXPEDITE THE COMPLETION OF THE PROJECT. COMPLETION OF THE PROJECT AND BEFORE TURNING THE PROJECT OVER TO THE 3. CONTACT UNISTRUT CORPORATION 800-468-9510. 4. ACCESSORIES AND TRIM: U.S. GYPSUM BOARD OR GOLD BOND SYSTEM OF COMPONENTS C. SIGNS/SIGNAGE: 3. FURNISH LABOR, MATERIALS, EQUIPMENT AND APPLIANCES NECESSARY TO COMPLETE THE TENANT. WORK TO INCLUDE, BUT NOT BE LIMITED TO ALL CEILING SURFACES, FLOOR AND PERFORATED TAPE. ALL METAL TRIM SHALL BE PERFORATED FLANGE TYPE FOR 1. REFER TO ELECTRICAL PLANS. INSTALLATION OF ALL ITEMS FURNISHED BY OTHERS. AND WALL SURFACES, BOTH INTERIOR AND EXTERIOR. THE STORE IS TO BE CLEAN AND COMPOUND FINISH. 2. ALL TEMPORARY SIGNS AND BANNERS ARE PROVIDED BY OTHERS. INSTALL ALL B. PROTECTION: READY FOR MERCHANDISING. 2. STOREFRONT IS TO BE CLEAN OF ALL DUST, GLUE, GROUT, AND MISAPPLIED PAINT. 5. PROVIDE A LEVEL 4 FINISH PRIOR TO THE APPLICATION OF THE FINAL FINISHES. REFER TEMPORARY SIGNS AND BANNERS PER OWNER'S DIRECTION. DIVISION VI WOOD +PLASTICS TO THE GYPSUM ASSOCIATION GUIDELINES FOR A DESCRIPTION OF THE DESIRED LEVEL. 3. STOREFRONT SIGN PROVIDED BY OTHERS. 1. ERECT A TEMPORARY BARRICADE AT THE STOREFRONT ONLY IF REQUIRED BY THE 3. HVAC FILTERS TO BE CHANGED FOLLOWING THE CLEANING. 4. COORDINATE INSTALLATION WITH TENANT'S VENDOR. GUIDELINES.. A. CARPENTRY & BLOCKING: B. CEILING SYSTEMS 2. PROTECT THE PROPERTY OF ADJACENT TENANTS, COMMON AREAS, AND NEUTRAL PIERS AT N. INSURANCE: 1. BEFORE USING WOOD FRAMING OR BLOCKING OF ANY TYPE, CONFIRM CODE 1. FURNISH AND INSTALL CEILING SYSTEMS COMPLETE WITH SUSPENSION SYSTEM AND ALL TIMES. ANY DAMAGE THAT OCCURS AS A RESULT OF DEMOLITION 1. SECURE, PAY FOR AND MAINTAIN, DURING CONSTRUCTION, ALL OF THE INSURANCE RESTRICTIONS. IF USE OF WOOD IS PERMITTED BY REQUIREMENTS, ADHERE TO THE RELATED ACCESSORIES AS INDICATED ON DRAWINGS.DIVISION DIVISION A EOUIPMENT (OR CONSTRUCTION) IS TO BE REPAIRED TO LIKE NEW CONDITION. POLICIES REQUIRED. WORK SHALL NOT COMMENCE UNTIL ALL REQUIRED INSURANCE HAS FOLLOWING GUIDELINES: USE NEW LUMBER BEARING GRADE AND TRADEMARK OF ASSOCIATION UNDER WHICH IT 2. ALL LIGHT GAUGE METAL FRAMING AND CEILING SUSPENSION COMPONENTS FOR SOFFITS, A. RECEIVE AND INSTALL PER MANUFACTURER'S INSTRUCTION ALL EQUIPMENT AND FIXTURES. BEEN OBTAINED AND CERTIFICATES OF SUCH INSURANCE HAVE BEEN DELIVERED. a. GYPSUM BOARD AND LAY -IN CEILINGS SHALL BE ANCHORED TO THE STRUCTURAL JOISTS C. CONTRACT CONSIDERATIONS: LANDLORD MUST BE NAMED AS "ADDITIONAL INSURED". CERTIFICATE OF INSURANCE WAS PRODUCED. AND BEAMS ONLY. PROVIDE AND INSTALL ANY ADDITIONAL FRAMING REQUIRED. B. AUDIO SYSTEM 1. SCHEDULE OF VALUES SHALL COVER WORK PERFORMED BY CONTRACTOR, EACH SUBCONTRACTOR AND ALL b. LAYOUT, CUT, FIT AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTALL 3. SUSPENSION SYSTEMS SHALL BE ADEQUATE TO SUPPORT LIGHTING FIXTURES CEILING a. SUBMIT A PRINTED SCHEDULE ON FORM INCLUDED WITH BID PROPOSAL. MAJOR SUPPLIERS. BLOCKING, NAILERS, FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS REQUIRED. GRILLES, DIFFUSERS, AND OTHER TYPICAL CEILING ACCESSORIES. 1. REFER TO ELECTRICAL PLANS. b. INCLUDE A DIRECT PROPORTIONAL AMOUNT OF OVERHEAD AND PROFIT WITH EACH LINE BRACE, PLUMB, AND LEVEL MEMBERS IN TRUE ALIGNMENT AND RIGIDLY SECURE IN PLACE 4. PROVIDE SYSTEM COMPONENTS FROM SINGLE MANUFACTURER. 2 PROVIDED BY OTHERS. COORDINATE INSTALLATION WITH TENANT'S VENDOR. ITEM. 0. INDEMNIFICATION: WITH SUFFICIENT NAILS, SPIKES, SCREWS AND BOLTS AS NECESSARY. 5. INSTALL CEILING AND SUSPENSION SYSTEMS IN STRICT ACCORDANCE WITH c. REVISE SCHEDULE TO LIST APPROVED CHANGE ORDERS, WITH EACH APPLICATION FOR 1. TO THE FULLEST EXTENT PERMITTED BY LAW, INDEMNIFY AND HOLD HARMLESS THE c. FURNISH AND INSTALL ROUGH AND FINISHED PLYWOOD, FURRING SUPPORTS, ETC. MANUFACTURER'S RECOMMENDATIONS AND ALL APPLICABLE BUILDING CODE REQUIREMENTS. PAYMENT. LANDLORD, TENANT, AND ARCHITECT AND THEIR AGENTS AND EMPLOYEES FROM AND d. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS, BOLTS, ETC. AS REQUIRED FOR FINISHED CEILING SHALL BE LEVEL, WITH JOINTS SNUG AND SQUARE, AND IN PERFECT DIVISION Al FURNISHINGS AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING BUT NOT LIMITED TO, CARPENTRY WORK. CONDITION. 2. PAYMENT AND WAIVER OF LIENS: ATTORNEYS FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE e. ALL EXISTING OR NEW WOOD SHALL BE FIRE RETARDANT AND MUST BE IDENTIFIED WITH 6. MATERIALS AND FINISHES: A. REFER TO THE RESPONSIBILITY SCHEDULE. a. PAYMENT APPLICATION FORMS: SUBMIT PER THE OWNER'S REPRESENTATIVE'S WORK, PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LOSS OR EXPENSE IS ATTRIBUTABLE A UL LABEL CERTIFYING THIS CLASSIFICATION. a. REFER TO REFLECTED CEILING PLAN FOR SPECIFIED MATERIALS AND FINISHES. REQUIREMENTS. TO BODILY INJURY, SICKNESS, DISEASE OR DEATH, OR TO INJURY OR TO DESTRUCTION b. LEAVE ONE CASE OF CEILING TILES FOR LATER REPLACEMENT. B. RECEIVE, ASSEMBLE AND PLACE OFFICE AND NON -SALES EQUIPMENT AND FIXTURES. b. U1ILIZE SCHEDULE OF VALUES FOR LISTING ITEMS IN APPLICATION FOR PAYMENT. OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF) INCLUDING THE LOSS OF USE B. MILLWORK: REFER TO RESPONSIBILITY SCHEDULE. c. ALL PAYMENTS FOR THIS PROJECT ARE TO BE ALLOCATED FOR THIS PROJECT ONLY FOR RESULTING THEREFROM. 1. RECEIVE AND INSTALL ALL OWNER PROVIDED FINISHED MILLWORK, CABINETS, PANELING, C. PAINTING AND FINISHING PAYMENTS TO SUB -CONTRACTORS, MATERIAL SUPPLIERS, AND AGENTS AUTHORIZED BY DOORS AND FRAMES, ETC., SHOWN ON DRAWINGS AS DIRECTED. 1. PROVIDE A SATISFACTORY FINISH THROUGHOUT UNLESS SPECIFICALLY STATED C. RECEIVE ASSEMBLE AND PLACE INSTALL ALL SALES AREA FIXTURES. / SPECIFIC CONTRACTORS TO PERFORM WORK OR SUPPLY MATERIALS TO THIS PROJECT. SUBMIT P. BACKGROUND COMPUTER -AIDED CONTRACT DESIGN DOCUMENTS: 2. CUT FIT AND INSTALL ALL MILLWORK AND SET PLUM AND TRUE IN ACCORDANCE WITH ALL M OTHERWISE. DIVISION XIII SPECIAL CONSTRUCTION PARTIAL WAIVERS OF LIENS INCLUDING SUBCONTRACTORS AND MATERIAL SUPPLIERS. 1. IN THE EVENT THAT THE GENERAL CONTRACTOR OR ANY SUBCONTRACTORS REQUIRE ASSEMBLY/INSTALLATION DRAWINGS PROVIDED. 2. USE ONLY THE PAINT AND RELATED MATERIALS SPECIFIED. d. SUBMIT A UPDATED CONSTRUCTION PROGRESS SCHEDULE. BACKGROUND DRAWINGS, COPIES OF THESE DRAWINGS MAY BE PROVIDED SUBJECT TO 3. BACK CUT FLAT TRIM TO PREVENT WARPING. DRILL WHERE NECESSARY TO PREVENT 3. COVER ALL SURFACES THOROUGHLY. IF THE NUMBER OF COATS SPECIFIED DOES NOT THE FOLLOWING CONDITIONS: SPLITTING. ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED MATERIAL TO GIVE 3. CHANGE PROCEDURES: " a. A SEPARATE AGREEMENT TITLED USE OF COMPUTER -AIDED DESIGN DOCUMENTS 4. CONFIRM BLOCKING REQUIREMENTS WITH VENDORS PRIOR TO CLOSING UP ALL SATISFACTORY COVERAGE. SEE FINISH SCHEDULE. , A. NO ANTICIPATED WORK UNDER THIS SECTION. CONFIRM WITH TENANTS REPRESENTATIVE. a. OWNER'S REPRESENTATIVE WILL ADVISE OF MINOR CHANGES IN THE WORK NOT INVOLVING MUST BE SIGNED BY THE CONTRACTOR/SUBCONTRACTOR BEFORE THE TRANSFER OF THE ASSEMBLIES. 4. PREPARE BY CLEANING ALL SURFACES FREE OF LOOSE DIRT AND DUST. PREPARE ALL AN ADJUSTMENT TO CONTRACT SUM/PRICE OR CONTRACT TIME. FILES. METAL SURFACES IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN SPECIFICATIONS. DIVISION XIV CONVEYING SYSTEMS b. MAINTAIN DETAILED RECORDS OF WORK DONE ON TIME AND MATERIAL BASIS TO b. CONTRACTOR MUST AGREE TO USE THE PROJECT FILES ONLY FOR THE LIMITED 5. PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED SUBSTANTIATE COSTS FOR CHANGES IN THE WORK. PURPOSE AS DESCRIBED IN THE AGREEMENT. PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT TO PRODUCE AN EVEN c. CHANGE ORDER FORMS: SUBMIT PER THE OWNER'S REPRESENTATIVE'S REQUIREMENTS. c. CONTRACTOR MUST AGREE TO REIMBURSE WJCA INC. OR THE TENANT FOR THE USE DIVISION VII THERMAL -I- MOISTURE PROTECTION RESULT IN THE FINISH COAT. DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCEEDING d. EXECUTION OF CHANGE ORDERS: OWNER'S REPRESENTATIVE WILL ISSUE CHANGE ORDERS OF THE DOCUMENTS PER THE AGREEMENT. CONTRACTOR MAY REIMBURSE WJCA INC. COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RE -COAT TIME. A. NO ANTICIPATED WORK UNDER THIS SECTION. CONFIRM WITH TENANT'S REPRESENTATIVE. FOR SIGNATURES OF PARTIES AS PROVIDED IN THE CONDITIONS OF THE CONTRACT. DIRECTLY OR MAY AGREE TO CREDIT TENANT AN AMOUNT AGREED UPON WITH ARCHITECT A. VAPOR BARRIER: 6. PUTTY ALL NAIL HOLES, COUNTER SUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE e. SUBMIT A UPDATED CONSTRUCTION PROGRESS SCHEDULE. &TENANT'S REPRESENTATIVE. 1. PROVIDE AND INSTALL 10 MIL. POLYETHYLENE BELOW ALL REQUIRED PATCH AREAS AT APPLYING FINISH. SLAB ON GRADE CONDITIONS AND 4 MIL. POLYETHYLENE AT WALLS THAT RECEIVE BATT 7. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. DIVISION XV MECHANICAL 4. ALTERNATIVES: Q. DAMAGED FREIGHT (TENANT FURNISHED MATERIALS): INSULATION. 8. BEFORE STARTING FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES, LIGHTING a. ACCEPTED ALTERNATIVES WILL BE IDENTIFIED IN OWNER -CONTRACTOR AGREEMENT. 1. OPEN BOXES CARTONS WITH OBVIOUS DAMAGE / B. CRACK BRIDGING: FIXTURES AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. b. ALTERNATES MUST BE SUBMITTED WITH BID PROPOSAL, AS SEPARATE ADD OR DEDUCT 2. INSPECT FREIGHT BEFORE SIGNING THE FREIGHT BILL, NOTE SPECIFICALLY THE ITEM(S) PROVIDE AND CRACK BRIDGING AS MANUFACTURED BY NATIONAL 1. PROVIDE AND INSTALL 9. PAINT ALL REGISTERS, LOUVERS, GRILLES, EMERGENCY LIGHTS, SPEAKERS, TRIM LIGHTS, EXPOSED PIPING, ACCESS DOORS, VENTS, FIRE EXTINGUISHER CABINETS, EQUIPMENT A. REFER TO MECHANICAL DRAWINGS FOR SPECIFICATIONS. ITEMS. BASE BID SHALL INCLUDE ALL ITEMS AND MANUFACTURERS AS ENUMERATED ON DRAWINGS AND/OR SPECIFICATIONS. DAMAGED. INC.0 APPLIED CONSTRUCTION PRODUCTS, I800-633-4622 OR APPROVED EQUAL. PRODUCTS, MOUNTING BOARDS ETC. UNLESS FACTORY FINISHED. PAINT TO MATCH ADJACENT WORK c. COORDINATE RELATED WORK AND MODIFY SURROUNDING WORK AS REQUIRED. 3. AFTER THE DAMAGE IS NOTED ON THE FREIGHT BILL, HAVE CARRIER'S DRIVER ALSO UNLESS OTHERWISE NOTED OR DIRECTED. DIVISION XVI ELECTRICAL SIGN IN ORDER TO VERIFY THAT BOTH PARTIES AGREE TO THE EXTENT OF THE DAMAGE. C. BATT INSULATION: 10. MAKE FINISH WORK UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, SAGS, 5. CLOSE OUT: 4. WHEN DAMAGE IS DISCOVERED UPON UNPACKING THE FREIGHT, INSPECT ALL PACKING 1. PROVIDE AND INSTALL A MINIMUM OF R-13 FRICTION FIT (OR AS DICTATED BY CODE), AND DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER THE FINAL TEN PERCENT RETENTION ON THIS PROJECT MUST INCLUDE SIGNED AND FOR SIGNS OF DAMAGE OR ABUSE. THE FREIGHT BILL IS TO BE NOTED WITH THE FULL BATT INSULATION AS MANUFACTURED BY OWENS-CORNING FIBERGLASS OR EQUAL AT MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. A. REFER TO ELECTRICAL DRAWINGS FOR SPECIFICATIONS. a. EXECUTED WAIVERS OF LIEN INDICATING 100% COMPLETION AND 100% PAYMENT IN FULL BY SPECIFIED DAMAGE. WITHIN 48 HOURS OF TAKING RECEIPT OF ALL EXTERIOR WALLS AND WHERE INDICATED IN THE DRAWINGS. ALL SUB -CONTRACTORS AND MATERIAL SUPPLIERS. 5. CONTACT THE TENANT'S REPRESENTATIVE D. CARPET: b. PROVIDE A LIST OF ALL SUBCONTRACTORS, INCLUDING ADDRESS AND PHONE NUMBERS MATERIALS TO INFORM THEM OF ANY LOSS. FAX ALL REQUIRED DOCUMENTATION TO D. WATERPROOF MEMBRANE: 1. REFER TO RESPONSIBILITY SCHEDULE AND FINISH SCHEDULE. INSTALLED IN A PICTURE FRAME ON BACK OF THE MANAGER'S OFFICE DOOR. TENANT'S REPRESENTATIVE. 1. PROVIDE AND INSTALL A (M) 30 MIL. (MIN.) WATERPROOF MEMBRANE. 2. CARPET AND ADHESIVE SHOULD BE CONDITIONED ON SITE AT A TEMPERATURE OF NO c. SUBMIT OPERATION MANUALS, MAINTENANCE INSTRUCTIONS, ETC. 6. IF TENANT'S CONTRACTOR FAILS TO FOLLOW THIS PROCEDURE, TENANT'S CONTRACTOR 2. EXTEND A MINIMUM OF 6" UP VERTICAL SURFACES IN TOILET ROOMS OR AS REQUIRED. LESS THAN 60 DEGREES. ALL SUBFLOORS MUST BE SMOOTH AND LEVEL, FREE OF DIRT, d. THE GENERAL CONTRACTOR SHALL PROVIDE ASBUILT DRAWINGS TO THE OWNERS SHALL BE RESPONSIBLE FOR ALL COSTS RELATED TO THE REPLACEMENT OF MISSING OR WAX AND OLD ADHESIVES. REPRESENTATIVE THAT REFLECTS ALL CHANGES TO THE PROJECT DURING THE CORES OF DAMAGED TENANT FURNISHED MATERIALS. E. FIRESTOPPING: 3. PROVIDE PREMIUM MULTI PURPOSE 1000 ADHESIVE TO ASSURE FULL WARRANTY CONSTRUCTION AT THE COMPLETION OF PROJECT. 1. PROVIDE AND INSTALL UL TESTED FIRESTOPPING ASSEMBLIES AS ARE APPLICABLE FOR PROTECTION IN ALL DIRECT GLUE APPLICATIONS. USE A MINIMUM OF 1/8 X 1/8 X 1/8 EACH CONDITION ENCOUNTERED. IN THE ABSENCE OF TESTED ASSEMBLIES, PROVIDE INCH V NOTCHED TROWEL FOR APPLICATION. ONE GALLON WILL HANDLE 10-15 YARDS OF D. QUALITY OF WORK: FIRESTOPPING ASSEMBLIES AS RECOMMENDED BY THE FIRESTOPPING SYSTEM CARPET. A DRYING TIME OF 30-40 MINUTES IS CRITICAL BEFORE PLACING THE CARPET 1. ALL WORK SHALL BE PERFORMED IN A SAFE AND WORKMANLIKE MANNER IN ACCORDANCE MANUFACTURER'S STAFF ENGINEERS AND AS APPROVED BY AUTHORITIES HAVING INTO THE ADHESIVE. DIVISION 11 SITE CONSTRUCTION WITH ACCEPTED CONSTRUCTION STANDARDS AND O.S.H.A. REQUIREMENTS. ALL CONSTRUCTION JURISDICTION. 4. PROVIDE AND INSTALL TRANSITION STRIPS. TRANSITION STRIPS MUST BE NEW SHALL BE IN STRICT ACCORDANCE WITH THE PLANS UNLESS A VARIANCE IS APPROVED BY THE 2. PROVIDE FIRESTOPPING MATERIALS AND THICKNESS AS REQUIRED TO MAINTAIN THE FIRE MATERIALS AND MUST CONFORM TO ALL CODE REQUIREMENTS AND INDUSTRY QUALITY A. VERIFY EXISTING CONDITIONS AND LOCATIONS OF UTILITIES, ROOF DRAINS, HVAC TENANT AND ALL AUTHORITIES HAVING JURISDICTION. RATINGS OF THE ASSEMBLIES INTO WHICH THE MATERIALS ARE INSTALLED. STANDARDS. 2. ALL EQUIPMENT AND MATERIALS UNDER THE CONTRACT ARE TO BE NEW UNLESS OTHERWISE EQUIPMENT, ETC. PRIOR TO COMMENCING THE WORK. 3. STRICTLY MATCH UL TESTED ASSEMBLIES. 5. COMPLETED INSTALLA1ON TO BE FREE OF STAINS OR SNAGS DUE TO CONSTRUCTION SPECIFIED IN THE PLANS. 4. INSTALL FIRESTOPPING WITHOUT GAPS AND VOIDS OF ANY KIND. WORK. B. DEMOLITION: 5. INSPECT FIRESTOPPING WORK AND REPAIR OR REPLACE WORK WHICH HAS BEEN E. CODE COMPLIANCE: 1. SCOPE OF WORK - THIS PORTION OF THE WORK INCLUDES ALL LABOR, MATERIALS DAMAGED, DISTURBED, OR REMOVED BEFORE FIRESTOPPING IS CONCEALED OR ENCLOSED. 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE CERTAIN THAT ALL WORK IS IN AND SERVICES NECESSARY FOR THE REASONABLY INCIDENTAL TO COMPLETE ALL 6. PROVIDE ANCHORAGE ACCESSORIES AND OTHER COMPONENTS AS NEEDED TO PROVIDE COMPLIANCE WITH ALL CODES, ORDINANCES, AND REGULATIONS OF ALL CONSTITUTED PUBLIC DISMANTLING, DEMOLITION, AND SALVAGE AS SHOWN AND NOTED ON THE DRAWINGS AND COMPLETE, EFFECTIVE FIRESTOPPING SYSTEMS COMPLYING WITH UL TESTED ASSEMBLIES. AUTHORITIES HAVING JURISDICTION. THIS INCLUDES BUT IS NOT LIMITED TO LOCAL BUILDING SPECIFIED HEREIN. IN GENERAL, THE ITEMS TO BE PERFORMED UNDER THIS SECTION CODE REQUIREMENTS, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, SHALL INCLUDE, BUT ARE NOT LIMITED TO: REMOVAL OF ALL EXISTING ACOUSTICS AND F. FIRE CAULKING: O.S.H.A., AND THE BEST TRADE PRACTICES. GYPSUM WALL BOARD, CEILING AND FRAMES, LIGHT FIXTURES, FLOORING, DOORS AND 1. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE WALLS, FURRED OUT COLUMN ENCLOSURES, AND STOREFRONT AND AS SPECIFIED ON THE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR E. RESILIENT SHEET FLOORING: F. DIMENSIONS: DRAWINGS. EQUAL. 1. REFER TO RESPONSIBILITY SCHEDULE AND FINISH SCHEDULE 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE MEASURED FROM FINISHED FACE TO 2. DISCONNECTION OF SERVICES: 2. ALL EDGE CONDITIONS AT TRANSITIONS TO BE FLOATED UP FOR SMOOTH EVEN FINISHED FACE OF MATERIALS, FACE OF STOREFRONT, OR LEASE LINE. a. EXISTING SERVICES THAT WILL BE DISRUPTED BY CONSTRUCTION WORK SHALL BE G. ACOUSTICAL INSULATION: TRANSITION. 2. VERIFY ALL PROPOSED DIMENSIONS WITH FIELD CONDITIONS. ADVISE TENANT'S RE-ROUTED AS NECESSARY TO PROVIDE TEMPORARY CONTINUATION SERVICE. 1. PROVIDE AND INSTALL ASTM C665, UNFACED, 0.32 K-VALUE, WIDTHS TO COORDINATE 3. ALL SUBFLOORS TO BE MOISTURE TESTED AND RESULTS COMPARED TO REPRESENTATIVE OF ANY DISCREPANCY BETWEEN THE DRAWINGS AND ACTUAL JOB CONDITIONS b. DISCONNECTED SERVICES SHALL BE PLUGGED AND SEALED IN AN APPROVED MANNER WITH FRAMING FOR FRICTION FIL, THICKNESS SHOWN OR IF NOT SHOWN, FILL CAVITY. MANUFACTURERS RECOMMENDED INSTALLATION GUIDELINES. ANY PROBLEMS DUE TO BEFORE BEGINNING THE WORK. c. SPRINKLER SHUT DOWN SHALL BE COORDINATED WITH THE BUILDING PRIOR TO MOISTURE TESTING TO BE REPORTED TO TENANT'S REPRESENTATIVE IMMEDIATELY. 3. ALL ANGLES SHALL BE 90 OR 45 DEGREES UNLESS OTHERWISE NOTED IN THE EXECUTION OF WORK. 4. RESILIENT SHEET FLOORING WITH INTEGRAL 4" HIGH, RADIUSED COVE BASE. SEE FINISH CONSTRUCTION DOCUMENTS. 3. ABANDONED ELECTRICAL WIRING: SCHEDULE. a. CONDUITS AND OTHER UTILITIES ENCOUNTERED IN THE PROGRESS OF THE DEMOLITION 5. FILL ALL CRACKS, JOINTS, ETC., IN SUB -FLOOR WITH CRACK FILLER APPROVED BY G. SHOP DRAWINGS & SUBMITTALS: THAT ARE TO BE ABANDONED SHALL BE DISCONNECTED AND THE ENDS PLUGGED IN AN FLOORING MANUFACTURER, 1. SUBMIT THE NUMBER OF OPAQUE REPRODUCTIONS WHICH CONTRACTOR REQUIRES, PLUS APPROVED MANNER. ANY ABANDONED UTILITIES INTERFERING WITH WORK UNDER THIS 6. INSTALL ALL MATERIALS WITH WEATHERPROOF TYPE ADHESIVES AS RECOMMENDED BY TWO COPIES, TO TENANT'S REPRESENTATIVE FOR APPROVAL. CONTRACT SHALL BE REMOVED ONLY TO THE EXTENT THAT THEY INTERFERE WITH NEW DIVISION VIII DOORS ♦ WINDOWS FLOORING MANUFACTURER FOR MATERIALS AND SURFACE INVOLVED. 2. SUBMITTALS MUST BE SCHEDULED SO AS NOT TO IMPEDE THE PROGRESS OF THE WORK. CONSTRUCTION. 3. MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AND OTHER A. DOORS AND HARDWARE: DATA. SUPPLEMENT MANUFACTURER'S STANDARD DATA TO PROVIDE INFORMATION SPECIFIC TO 1. FURNISH AND INSTALL ALL DOORS, FRAMES, HARDWARE AND RELATED PARTS AND DIVISION III CONCRETE THIS PROJECT. MATERIALS AS INDICATED ON DRAWINGS AND RESPONSIBILITY SCHEDULE. 4. INDICATE SPECIAL UTILITY AND ELECTRICAL CHARACTERISTICS, UTILITY CONNECTION 2. HOLLOW METAL FRAMES: K.D. MINIMUM 16 GA. SIZE, SHAPE AND PARTITION TYPE PER A. PATCHING (WHEN REQUIRED) REQUIREMENTS, AND LOCATION OF UTILITY OUTLETS FOR SERVICE FOR FUNCTIONAL EQUIPMENT DOOR SCHEDULE. AND APPLIANCES. 1. INSTALL MINIMUM 3000 PSI CONCRETE FILLER AND PATCHING WHERE EXISTING SLAB 3. LABELED DOORS: PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE STATE 5. IDENTIFY VARIA11ONS FROM CONTRACT DOCUMENTS AND PRODUCT OR SYSTEM LIMITATIONS HAS BEEN REMOVED FOR UNDER SLAB CONDUITS, PLUMBING, ETC. AND LOCAL BUILDING CODES, WHERE REQUIRED. WHICH MAY AFFECT THE CONSTRUCTION PROGRESS. 4. FABRICATE AND ERECT TRUE, PLUMB, AND SQUARE AS SPECIFIED AND DETAILED AND 6. DIRECT ALL SUBMITTALS TO THE TENANT'S REPRESENTATIVE. B. CONCRETE SLAB AS PER MANUFACTURER'S RECOMMENDATIONS. 1. INSTALL MINIMUM 3000 PSI CONCRETE WITH 6" X 6" - W1.4 X W1.4 W.W.F. AT MID 5. AUTOMATIC SLIDING DOORS, ALUMINUM DOORS AND FRAMES WITH SIDELIGHTS, TRANSOM H SAMPLES: LEVEL OVER 6 MIL. VAPOR BARRIER (AT SLAB ON GRADE CONDITIONS OR ADHERE TO AND ACTIVE DOOR LEAVES, OVERHEAD OPERATOR AND EMERGENCY BREAKOUT PER APPLICABLE 1. SUBMIT THREE COPIES OF SAMPLE TO TENANT'S REPRESENTATIVE FOR APPROVAL WHEN REQUIRED BY INDIVIDUAL SPECIFICATION SECTION. LOCAL CODE REQUIREMENTS. INSTALL CONTROL JOINTS AT MAXIMUM 200 SF. ) BUILDING CODES. 6. SEE DOOR SCHEDULE FOR SPECIFIC INFORMATION AND HARDWARE. 2. INCLUDE IDENTIFICATION ON EACH SAMPLE WITH FULL PROJECT INFORMATION. DIVISION IV MASONRY It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. V) z O V) > w w L 0 0 U W W V) a 0 a w U m 0 0Lj Q C14in 0 n 0 c rn co m O c E2 ca J N co 0 J IL 0 0 CO (0 U d e d � N N O 0 _ Y z M CD o W00 OW �V' WC ~U J LL (1) Q WU � 0 CL 03j 0 E;3 CCWW o• W c °' Q 6 Z 03: a r 0 Lo 0 Z ii cuo -= 0 r -j 3 a. u- PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG SPECIFICATION/GENERAL NOTES SHEET NO. G3.0 4 24" 36" 0 i CV C f -P1---' 12" 28" 18" VERT MAX W1 9 � � Cal 427 " 13 O 8" D1 — 2 RR ELEVATION SCALE: 3/8"=1'-0" '-- EX 4'-8" 18" VERT h l—. 42"-\ O d I 0 CV tx PIPE PROTECTION KIT. Q SEE FIXTURE NOTES 15" 6 RR ELEVATION SCALE: 3/8"=1'-0" a af M O O o Qf O U m< 0� xN act MO Q M � rLvvr� rLHiv 3 RR ELEVATION SCALE: 3/8"=1'-0" EX ' EX - � RR ELEVATION SCALE: 3/8"=1'-0" a d mnv. 4 RR ELEVATION SCALE: 3/8"=1'-0" EX EX EX c . FA ",P1--, 4'-6" 0 o O` l 18" o VERT m Q ° LL. O \ " x cn ti, 36" 9 42 MO 0 MW M r- 24" d Q lt m O a o� W1 �� m i o B1 ^ N PIPE PROTECTION KIT. 15" 18" B1 SEE FIXTURE NOTES 5 RR ELEVATION SCALE: 3/8"=1'-0" EX. B.O. CLG 8 -0 36" o� 70 N Ln L/ 8 RR ELEVATION RR ELEVATION SCALE:3/8"=1'-0" 9 SCALE:3/8"=1'-0" OF 0 KEYED PLAN NOTES:01 ❑�, s��,�, 1 1. INFILL EXISTING OPENING WITH LIKE MATERIALS, TO MATCH EXISTING SURROUNDING WALLS. 2. EXISTING DOOR TO REMAIN. PROTECT DURING DEMOLITION AND CONSTRUCTION. 3. EXISTING COLUMN TO REMAIN. 4. EXISTING MOP SINK AND HOT WATER ABOVE TO REMAIN. REF: P1.0. 07 20 201 i 5. ADA CLEAR FLOOR AREA (TYP.). 6. INSTALL NEW MIRROR. 7. INSTALL NEW TOILET ROOM SIGNAGE. 8. INSTALL NEW GRAB BARS. 9. INSTALL NEW TOILET PAPER DISPENSER. 10. INSTALL NEW BABY CHANGING STATION. 11. INSTALL NEW UTILITY HOOKS. It is a the lar 12. INSTALL NEW SOAP DISPENSER. any person, u�nlessf acting under the direction of a licensed Architect, Engineer or Land 13. INSTALL NEW CHILD SEAT. Surveyor, to alter an item to any way. Plans, maps, specifications, studies, and 14. INSTALL NEW PAPER TOWEL DISPENSER. reports not containing a red ink seal imprint on the cover sheet accompanied by an original 15. RFI OCATFD SINK. PATCH N. RFPAIR TO "I IKF CONDITION" WHFRF DFMO IS RFOUIRFD TO signature by the licensed professional may have been fraudulently altered and shall not be considered an original GENERAL NOTES copy. Copyright Protected 2018, Larson Design Group. A. VERIFY INTERIOR AND EXTERIOR DIMENSIONS, NOTIFY ARCHITECT IMMEDIATELY WITH DISCREPANCIES. B. REFER TO A2.0 FOR DOOR SCHEDULE AND FOR FINISH KEY. C. DIMENSIONS SHOWN ARE CLEAR DIMENSIONS GYP BD TO GYP BD. D. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALING ON THE CONSTRUCTION DOCUMENTS. DO NOT SCALE. E. UPON POSSESSION OF THE PREMISES, DIMENSIONS OF SPACE SHALL BE VERIFIED G.C. SHALL SUBMIT NOTED DISCREPANCIES TO THE ARCHITECT/ENGINEER, TENANT PROJECT MANAGER, AND REQUIRED VENDORS WITHIN 3 DAYS OF THE START OF CONSTRUCTION. z F. PATCH & FIRE STOP GYP. BD. PARTITIONS AS REQUIRED BY LOCAL CODES. o G. APPROVED FIRE EXTINGUISHERS SHALL BE FURNISHED AND INSTALLED BY GC AS w w REQUIRED BY LOCAL AUTHORITY. 0 0 H. ALL SALES AREA WALLS TO BE FLUSH, LEVEL, AND SQUARE. w I. EXISTING CONDITIONS TO REMAIN TO BE PATCHED, REPAIRED, OR REPLACED TO BRING TO "LIKE NEW" CONDITIONS, VERIFY REUSE WITH LANDLORD MANAGER. a 0 J. REF: G1.2 FOR ALL ADA DETAIL MOUNTING HEIGHTS 0 K. PROVIDE ALL NECESSARY BLOCKING FOR ALL WALL MOUNTED ITEMS. w U L. DOOR TRIM VENDOR SUPPLIED MOLDING. 00 0 M. INSTALL NEW ADA COMFORMING WHEELCHAIR ACCESSIBLE LAVATORY P-TRAP AND o a ANGLE VALVE ASSEMBLIES. N o 4OTE: ,LL RESTROOM PLUMBING FIXTURES/ACCESSORIES 0 BE INSTALLED PER 2010 ADA STANDARDS. 4OTE: JSULATE ALL EXPOSED HOT WATER AND DRAIN INES. LEGEND SYMBOL DESCRIPTION EXISTING PARTITION NEW WALL CONSTRUCTION X WALL TYPE (SEE WALL TYPE SCHEDULE ON SHEET A2.0) XXX DOOR DESIGNATION (SEE DOOR SCHEDULE ON SHEET A2.1) RESTROOM ACCESSORIES SCHEDULE DESCRIPTION MANUFACTURER / CATALOG NO. GRAB BARS BRADLEY CORPORATION SERIES 812 - 1 1/2"0 STANDARD FINISH, OR EQUAL TOILET PAPER DISPENSER BRADLEY CORPORATION #5224 OR EQUAL MIRROR BRADLEY CORPORATION #781 - 18"W x 30" H PAPER TOWEL DISPENSER BRADLEY CORPORATION #250-15 OR EQUAL SOAP DISPENSER IMPERIAL BAG & PAPER CO. GOJO CHROME DISPENSER #1919-04 BABY CHANGING STATION KOALA CORPORATION #KB208-01, SURFACE MOUNTED, BABY CHANGING STATION & IDENTIFYING DOOR PLAQUE. FINISH: GRAY CHILD PROTECTION SEAT KOALA CORPORATION #KB102, SURFACE MOUNTED, BABY CHANGING STATION & IDENTIFYING DOOR PLAQUE. FINISH: GRAY UTILITY HOOK BOBRICK #B-670, SURFACE MOUNTED, STAINLESS STEEL, BRIGHT POLISHED FINISH, 1 /2"x2", FLANGE 2%2" UNDERSINK PIPE COVER TRUEBRO LAV. SHIELD #2018-AS-L1 20%18" FIXTURE NOTES: A. REF: G1.2 FOR ALL ADA DETAIL MOUNTING HEIGHTS B. ALL ADA CONFORMING, WHEELCHAIR ACCESSIBLE LAVATORY P-TRAPS AND ANGLE VALVE ASSEMBLIES TO BE COVERED WITH THE MOLDED, ANTIMICROBIAL TRUBRO, INC "LAV-GUARD" UNDERSINK PROTECTIVE PIPE COVER MODEL #103. C. ALL PLUMBING ACCESSORIES TO BE SUPPLIED & INSTALLED BY G.C. D. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING PLUMBING FIXTURES & EXISTING ACCESSORIES (INCLUDING LANDLORD INSTALLED PLUMBING FIXTURES & ACCESSORIES) COMPLY WITH PLANS & HANDICAPPED CODES AND LAWS. CONTRACTOR SHALL VERIFY COMPLIANCE TO FLOOR PLAN, ENLARGED PLANS & ELEVATIONS THIS SET. NOTIFY ARCHITECT WITH ANY DISCREPANCIES. n N CA $ J LL in E 0 0 cD U V, N n O O� LL CM O M LU Z� co) ao� � 0 W t"' W e W LLLL N Q J v W 0 � ao 03 �J E a:0 3 3 L C J ` 0 • 0 CL (D n '? Z E O 3 U En L o v Z cco_O Obi r -�0�aLL PROJECT NO. 11979-002 DRAWN BY EBG APP\,D BY RJG FLOOR PLAN SHEET NO. A1.0 MATERIAL SCHEDULE ABRV MATERIAL MANUFACTURER STYLE/COLOR SIZES NOTES FLOORS F1 VCT ARMSTRONG #51809 "DESERT BEIGE" 12"x12" 1 BASE B1 RESILIENT BASE G.C. SELECTION "BLACK" 4" COVE -- PAINT P1 PAINT SHERWIN WILLIAMS "WHITE" (G.0 SELECTION) -- 2 WALLS W1 FRP MARLITE COMPANY #P-100 WHITE 4'x8' SHEET 4 CEILING T-C, ACOUSTICAL ARMSTRONG #770 "CORTEGA" (WHITE) 2'x4' 3 COLOR LEGEND NOTES 1. 2. 3. 4. MATTE FINISH SEMI -GLOSS ENAMEL FINISH INSTALL IN PRELUDE-ML "WHITE" GRID SYSTEM PEBBLE WITH MATCHING WHITE TRIM AT EDGES, ALL TRIMMED EDGES TO BE MITERED. HOLD FRP CONNECTORS 4" AFF. NOTE: G.C. TO VERIFY ALL FINAL FINISH AND COLOR SPECIFICATIONS WITH TENANT/CLIENT PRIOR TO INSTALLATION. INTERIOR MATERIALS FIRE + SMOKE INDEX RATINGS MATERIAL FLAME SPREAD SMOKE DEV. INDEX CLASSIFICATION PAINT 15 5 1 VINYL TILE .45 450 OR LESS 2 LAY IN CEILING 25 10 1 WALL BASE .45 450 OR LESS 2 FRP 150 424 2 VINYL COMPOSITION TILE .45 450 OR LESS 2 SEALER 10 10 1 CLASS 1: FLAME SPREAD 200: SMOKE DEVELOPMENT 0-25 CLASS 2: FLAME SPREAD 450: SMOKE DEVELOPMENT 26-75 CLASS 3: FLAME SPREAD 450: SMOKE DEVELOPMENT 76-266 H-1 METAL STUDS BRACE CHART METAL STUD SIZE MAXIMUM UNBRACED HEIGHT 3 5/8" X 25 GA. 11'-3" 3 5/8" X 20 GA. 14'-0" 3 5/8" X 16 GA. 18'-0" 6" X 25 GA. 16'-0" 6" X 20 GA. 21'-0" 6" X 16 GA. 25'-0" NOTES 1. ALL METAL STUDS TO BY BY CONSOLIDATED FABRICATIONS CORP. (CFC) ISS EST-3064P. ALLOWABLE UNBRACED HEIGHT AS PER CHART ABOVE 2. ALL CONNECTION AND FASTENERS TO BE AS PER DETAILS. ALL MANUFACTURERS AND ICC ESR# TO BE STRICTLY ADHERED TO BY G.C. UNLESS APPROVAL FOR EQUAL SUBSTITUTION IS RECEIVED FROM THE BUILDING DEPARTMENT. 3. ALL GYPSUM BOARD TO BE 5/8" TYPE "X" THROUGHOUT. ATTACH WITH 1" TYPE S DRYWALL SCREWS 12" O.C. VERTICALLY AT STUDS AND 8" O.C. AROUND PERIMETER. UNLESS NOTED OTHERWISE SALES HOLD GWB 1/2" SHY OF DECK - PROVIDE SEALANT AS REVD, FULL LENGTH OF WALL SECURE W 1' S-12 STEEL P HEAD SCREWS 0 24" O.C. 3 A2.0 RESTROOM BOTTOM OF DECK (1) LAYER 5/8" GWB. STOP 6' ABOVE ACT CEILING. 3 A2.0 RESTROOM SECURE W/1" S-12 STEEL PAN HEAD BOTTOM OF DECK OZ 0 SCREWS 0 24' O.C. U LLI (1) LAYER 5/8" � GWB. STOP 6" �o ABOVE ACT CEILING. i \-- ACT CEILING \- ACT CEILING ACT CEILING REF: A3.0. REF: A3.0. REF: A3.0. EXISTING WALL 3-5/8" METAL STUDS 0 16' O.C. 6" METAL STUDS 0 16" O.C. 5/8' GYP. BOARD 5/8" GYP. BOARD BOTH SIDES (NO GYP REQ'D AGAINST BOTH SIDES -� EXISTING WALL WALL BASE WALL BASE AS SCHEDULED AS SCHEDULED FLOOR FINISH 4 FLOOR FINISH AS SCHEDULED AS SCHEDULED A NON -RATED WALL -TERMINATE 0 DECK n WALL TYI�E� SCA 2 M METAL STUD WITH (2)- #8 TIES TO UNDERSIDE OF DECK. B NON -RATED WALL -_.TERMINATE 0 DECK 0 X/ I '--UNDERSIDE OF DECK (4) #8 TEK SCREWS METAL STUD DIAGONAL BRACING TO STRUCTURE AT 48" O.C. ALTERNATE DIRECTION BRACING ATTACHMENT DETAIL SCALE: Y=1'-0" CONNECTIONS SHOULD BE TO TOP OF BAR JOIST OR VIA ADDITIONAL STL. OR UNISTRUT WHERE NECESSARY. \-CONTINUOUS DEEP LEG DEFLECTION CONTINUOUS TRACK WITH (1) TRACK (1 1 /2" MIN.DEEP LEGS). TEK #12 SCREW (ESR# 1976 CONNECT TO BOTTOM OF PURLIN WITH IN EACH FLANGE OF EACH (2) TEK #12 SCREWS (ESR# 1976) STUD 0 16" O.C. DECK (-3-ATTACHMENT DETAIL SCALE: Y=1'-0" 3 5/8" METAL STUDS 0 16" O.C. USE 6" METAL STUDS IN PARTITIONS CONTAINING PLUMBING LINES .rr/-#8 SCREWS EA. SIDE OF STUD TO TRACK (TYP.) CEMCO METAL STUD TRACK (TYP.) ICC # ESR 3016 A, Xr:-CONCRETE SLAB 177 DIA. HILTI POWDER ACTUATED FASTENER WITH 3/4'" EMBEDMENT AT 24" O.C. ICC # ESR 1663 FLOOR ATTACHMENT DETAIL SCALE: Y=1'-0" DOOR SCHEDULE DOOR NOTES DOOR FRAME FIRE RATING 1. ALL HARDWARE REPRESENTS THE INTENDED QUALITY, EXISTING EXISTING SIZE DETAIL HDW SET DOOR NOTES STYLE AND APPEARANCE. CONTRACTOR TO PROVIDE DOOR NO ROOM NEW RE -WORK NO -WORK MAT TYPE MATL TYPE LABEL HARDWARE CUT SHEETS TO TENANT PROJECT W H T HEAD JAMB SILL 2. MANAGER PRIOR TO CONSTRUCTION. ALL LOCKS TO BE PROVIDED WITH "BEST 7-PIN" INTERCHANGEABLE CORES AND CYLINDERS 101 SALES • 3'-0" 7'-0" 1 3/4" ALUM -- -- -- -- -- -- -- -- 3,4 102 STOCKROOM • 3'-0" 7'-0" 1 3/4" HM -- -- -- -- -- -- -- -- 3,4 3. AT EXISTING DOORS -REPLACE DAMAGED OR MISSING 103 OFFICE • 3'-O" 7'-0" 1 3/4" HW -- -- -- -- -- -- -- -- 3 HARDWARE, REPLACE LOCK CYLINDERS AND PROVIDE TENANT WITH (2) NEW KEYS 104 FITTING ROOM • 3'-0" 7'-0" 1-3/4" HW -- -- -- -- -- -- -- -- 3 4. PROVIDE ANY REQUIRED SIGNAGE AT EXIT OF SERIVCE 105 FITTING ROOM • 3'-0" 7'-0" 1 3/4" HW -- -- -- -- -- -- -- -- 3 5. 6. DOOR. CONTACT LANDLORD REPRESENTATIVE. PAINT DOOR & FRAME TO MATCH ADJACENT WALL. INSTALL DOOR STOPS WHERE A DOOR WOULD STRIKE 106 RESTROOM • 3'-0" 7'-0" 1 3/4" HW -- -- -- -- -- -- -- -- 3 107 RESTROOM • 3'-0" 7'-0" 1 3/4" WD A H.M. 1 H-1 J-1 S-1 -- 1 1,2,5,6,7,8 A WALL OR OTHER PART OF CONSTRUCTION WHEN OPEN. HARDWARE NOTES 7. INSTALL NEW DOOR CLOSING HARDWARE SO THAT HDW #1 CLOSING SPEED FROM 70' OPEN TO 3" FROM THE • HINGES: BALL BEARING HINGES: PBB BB81 4 LATCH IS 3 SECONDS MINIMUM AND THAT THE SPEED 1 /2" X 4 1 /2" FINISH: SATIN CHROME FROM 90' OPEN TO 12' FROM THE LATCH IS 5 • PRIVACY LOCK SET: "SCHLAGE" AL40S SECONDS MINIMUM (PER 2010 ADA STANDARDS). IN FINISH: SATIN CHROME • CLOSER: DOR-O-MATIC SC81 FINISH: NECESSARY, ADJUST DOOR CLOSER(S) TO REQUIRE ALUMINUM LESS THAN 5 LBS OF FORCE TO OPERATE. • DOOR STOP: IVES TYPE 436 FINISH: SATIN CHROME 8. UNDERCUT DOOR 1" • KICKPLATE: HIAWATHA 10"04" FINISH: SATIN STAINLESS • SILENCER: IVES, NO. 20 5/8" GYP. BD. TYP. EA. SIDE METAL STUDS CAULK EACH SIDE H.M. FRAME (TYP.) DOOR AS SCHED FRAME DETAILS - SCALE: 1-1 /2"=1'-0" J-1 5/8" GYP. BD. TYP. EA. SIDE STEEL STUDS CAULK EACH SIDE H.M. FRAME (TYP.) DOOR AS SCHED S-1 4S SCHED -RAME BEYOND EET A1.0 FOR MATERIAL A. 6 DOOR TYPES C.i HOLLOW METAL P4 (AS REQ'D PER ELEVATIONS 2" " & SCHEDULE) 1. 2 FRAME TYPES o2.1aT Nil i L 's f9> r 4 It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. to z 0 1- > w w M� M 0 U LLI F_ Q 0 a F_ w J U 00 0 �� 00 cl a J IL z E 0 0 00 (0 U 6 E co a Cl) a c � 'vrn 0 rno 3W LV, WC J 0 B LL rn W J 0 a o V F- W: 0 `O 3 JZ �o W C ID E-�c5"4 0 ot,M z E 3 c 0 U) 0 E LZLJ 00 CU 0 0Job r a PROJECT NO. 11979-002 DRAWN BY EBG APPv'D BY RJG WALL TYPES & DETAILS SHEET NO. A2.0 REFLECTED CEILING LEGEND SYMBOL DESCRIPTION NEW 2X4 ACT CEILING I I EXISTING 2X4 ACT CEILING 01 NEW 2X4 LED PANEL LIGHT L� EXISTING 2X4 LIGHT 0'-0" FINISHED CEILING HEIGHT NEW EMERGENCY SIGN NEW SUPPLY DIFFUSERS. �^ EXISTING SUPPLY DIFFUSERS. 0 NEW EXHAUST DIFFUSERS. z EXISTING EXHAUST DIFFUSERS. GENERAL NOTES A. GC TO VERIFY ALL CONDITIONS AT CEILING AREAS PRIOR TO INSTALLATION OF NEW MATERIALS. NOTIFY ARCHITECT OF ANY EQUIPMENT, PIPING, OR OTHER OBSTRUCTIONS THAT MAY INTERFERE WITH DESIGNATED WORK. B. ELEVATION HEIGHTS SHOWN ARE MEASURED ABOVE BLDG FINISHED FLOOR UNLESS NOTED OTHERWISE. C. REFER TO LIGHTING PLAN FOR MORE INFORMATION ON LIGHTING. D. EXISTING CEILING SYSTEM TO REMAIN UNLESS NOTED OTHERWISE. REPLACE ANY DAMAGED ACT / GYP CEILING SYSTEM. E. ALL NEW CEILING TILES TO MATCH EXISTING. F. REFER TO MECHANICAL PLANS FOR MORE INFORMATION ON MECHANICAL EQUIPMENT. KEYED NOTES: ❑X 1. EXISTING ACT CEILING TO REMAIN. PATCH & REPAIR AS REQUIRED. OF Ptti Ins .��- ''•. ��;' G 221 It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. V) z O_ V) U) I- > w W 0 0 U W U) fn Ljj Q 0 a Z) F- z w J 0 LN H \ �0 0 V F REFLECTED CEILING PLAN J U. C 0 Q Cf) (0 0 2 ( d 03�4) Mo 'm YQ o W r U)N 00 a 0W ai W LN W° J • LL i a W � V Ca 0 3 CC cc 3 0 -Y 3 L L' I� I'`� • J 0 d- (0 W c°a Vi CL U 'v�i � Z L O N E Only 3 c v c- L o No E Z li Mo -= J0311 U- r PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY R,JG REFLECTED CEILING PLAN SHEET NO. A3.0 �ej:L121c1/11KC47,1 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS (IF PROVIDED AS PART OF THE CONTRACT) ARE A PART OF THIS CONTRACT. 2. HE TERM "CONTRACTOR" SHALL MEAN THE "MECHANICAL CONTRACTOR HIRED TO COMPLETE THE WORK OUTLINED IN THESE PLANS AND SPECIFICATIONS" UNLESS OTHERWISE SPECIFIED. 3. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO REVIEW ALL DRAWINGS FOR ALL OTHER TRADES. 4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ITS SUBCONTRACTORS WITH A FULL SET OF BID DOCUMENTS INCLUDING SPECIFICATIONS AND MUST COORDINATE ITS WORK AND INSPECTIONS AND THE WORK AND INSPECTION OF THEIR SUBCONTRACTORS WITH ALL OTHER TRADES ON SITE TO CONFORM WITH THE GENERAL CONTRACTOR'S TIME SCHEDULE. 5. BY SUBMITTING A QUOTATION OR PROPOSAL THE MECHANICAL CONTRACTOR EXPRESSLY STATES AND WARRANTS THAT. ALL DRAWINGS AND SPECIFICATIONS HAVE BEEN THOROUGHLY REVIEWED, CONTRACTOR HAS BECOME FAMILIARIZED WITH JOB SITE CONDITIONS AND IS TOTALLY QUALIFIED TO PERFORM ALL OF THE WORK REQUIRED. 6. BEFORE SUBMITTING A FINAL PROPOSAL THE CONTRACTOR SHALL EXAMINE THE SITE OF THE PROPOSED WORK TO DETERMINE THE EXISTING CONDITIONS THAT MAY AFFECT THE PROPOSAL. IF DISCREPANCIES ARE NOTED BETWEEN THE DOCUMENTS AND THE EXISTING CONDITIONS THE ARCHITECT SHALL BE NOTIFIED AND THE CONTRACTOR SHALL RECEIVE CLARIFICATION BEFORE SUBMITTING A BID. THE SUBMISSION OF A PROPOSAL SHALL INDICATE THAT ALL CHARGES AND COSTS MADE NECESSARY BY EXISTING CONDITIONS ARE INCLUDED AND THAT THE COMPLETE SYSTEM AS DESCRIBED HEREIN WILL BE FURNISHED AT THE PROPOSED COST. 7. WHEN USED, THE TERM "PROVIDED BY CONTRACTOR" SHALL BE INTERPRETED AS MEANING "FURNISHED AND INSTALLED BY CONTRACTOR" WITH THE EXCEPTION WHERE ITEMS ARE "PROVIDED BY TENANT" SHALL BE INTERPRETED AS MEANING "FURNISHED BY TENANT (INSTALLED BY CONTRACTOR)", EXCEPT WHERE NOTED OTHERWISE. 0 1. THE MECHANICAL SUBCONTRACTORS QUOTING ON THEIR SPECIFIC SCOPE OF WORK/SERVICES TO CONTACT THE LOCAL BUILDING DEPARTMENT/AGENCY TO DISCUSS CODE ISSUES/IDIOSYNCRASIES REGARDING THEIR SERVICES AND THE QUOTE ASSOCIATED WITH THE SERVICES TO THE GENERAL CONTRACTOR FOR THIS PROJECT. THIS CONTRACTOR TO BE FAMILIAR NH THE SITE WHERE SUCH SERVICES/WORK WILL BE PERFORMED THIS SPECIFIC USE AND THE IDIOSYNCRASIES ASSOCIATED NH THE QUOTES ANY ITEMS HEALTH STHAT ARE NOT NECESSARILY SHOWN INDICATE HON DRAWN GS/S P ECI FI CATIONS. 2. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS TRANSPORTATION INCIDENTALS AND DETAILS NECESSARY TO PROVIDE COMPLETE AND FULLY FUNCTIONAL MECHANICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS IF SUPPLIED AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH LANDLORD AS REQUIRED. FIELD VERIFY PIPE AND DUCTS SERVING THE OT�NANQTUSPACEN PRIOR TO SUBMIISS ON OF IBID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN HOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS BUT WHICH IS NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF THE CONTRACT. 4. WHERE THE DRAWINGS AND / OR SPECIFICATIONS CALL FOR ITEMS WHICH E NGLORE'STEMNCDNDESRBEDTRESPONSIBLEFORPROVIDIITHYSASESIGDANDCION HE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 5. THE CONTRACTOR SHALL OBTAIN AND COMPLY WITH DETAILED REQUIREMENTS OF LEASE EXTRACTS FROM THE LANDLORD AND TENANT. 6. COORDINATE LOCATIONS OF ALL AIR OUTLETS WITH ALL WALLS LIGHTS, SPRINKLER HEADS, CEILING TILES AND DECORATIVE CEILING FIXTURES PRIOR TO INSTALLATION. 7. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ISCRESPONSIBLOE FOR OPERATION, SERVICE SUFFICIENT ACCESS TO ALLLEEQUIPMENTCFORHACTOR SERVICE. CFiANNTHE INGOANDAPATCH NG REQUUIRED FOR ANY WORK UNIDER GfHISH COOT ACT. CUTTING SHALL HAVE PRIOR APPROVAL BY HE TENANT'S CONSTRUCTION MANAGER AND THE LANDLORD OR LANDLORD'S REPRESENTATIVE. PATCHING SHALL MATCH FINISH OF SURROUNDING AREA. C. CODES 1. ALL WORK SHALL BE PERFORMED IN A NEAT AND PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. ALL WORK SHALL CONFORM TO THE LATEST ANDPORDINANCES• OTHE LATEST EDI11ONS ROTE ASHRAE STANDARDS ATNHE LIIFE SAFOETY CODE THE APPLICABLE BUILDING CODE, UNDERWRITERS LABORATORIES, THE NATIONAL ELECTRICAL CODE NFPA 70 90A AND 96 AND ALL OTHER APPLICABLE CODES ENFORCED BY AUTHORITIES HALING JURISDICTION. THE CHANGES REQUIRED BY ANY APPLICABLE CODES SHALL BE INCLUDED IN THE BID. AFTER THE CONTRACT IS ISSUED TO THE I ZONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE TENAND. LICENSES. PERMITS. INSPECTIONS AND FEES 1. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED OR RELATED TO THIS WORK. 2. FURNISH TO HE TENANT'S CONSTRUCTION MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. E. DRAWINGS 1. DRAWINGS PLANS AND SPECIFICATIONS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE MECHANICAL SYSTEMS. BECAUSE OF THE SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL DUCT AND PIPE OFFSETS FITTINGS AND ACCESSORIES THAT MAY BE REQUIRED. THE MECHANICAL CONTRACTOR MUST OBTAIN APPROVED CONSTRUCTION DRAWINGS FROM THE GENERAL CONTRACTOR BEFORE BEGINNING ANY WORK. 2. THE LAYOUT SHOWN ON THE DRAWINGS IS BASED ON A PARTICULAR MAKE OF EQUIPMENT. IF ANOTHER MAKE OF EQUIPMENT IS USED WHICH REQUIRES MODIFICATION OR CHANGE OF ANY DESCRIPTION FROM HE R D AWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE AS PART OF THIS WORK, FOR MAKING ALL SUCH MODIFICATIONS AND CHANGES INCLUDING HOSE INVOLVING OTHER TRADES WITH THE COST HEREOF INCLUDED IN THE BID. IN SUCH CASE CONTRACTOR SHALL SUBMIT DRAWINGS AND SPECIFICATIONS PRIOR TO STARTING WORK SHOWING ALL SUCH MODIFICATIONS AND CHANGES. THE PROPOSAL SHALL BE SUBJECT TO THE APPROVAL OF HE TENANT'S CONSTRUCTION MANAGER. F. EXISTING LEASE SPACE CONDITIONS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING MECHANICAL WORK IN THE SPACE NOT SHOWN TO BE REUSED IN THE NEW TENANT SPACE. 2. THE CONTRACTOR SHALL INCLUDE AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING FIRE PROTECTION PLUMBING FIXTURES PIPING HVAC UNITS, REFRIGERANT RECAPTURE EXHAUST FANS DUCTWORK, ETC. AND ASSOCIATED ROOF CURBS NOT TO BE REUSE6 ON THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ROFDOUSESALEDDTEPTCENTEDOFOOCRBHLBREMO�tl) AND ROOF AHD PRIOR TO REUSE OR RECONFIGURATION ON PLANS. ROOF PATCHING SHALL BE PERFORMED AT THE CONTRACTOR'S EXPENSE BY A ROOFING CONTRACTOR APPROVED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF ABOVE THIS SPACE) NOT APPLICABLE TO THE NEW WORK OR PART OF THE LANDLORD'S OR ANOTHER TENANT'S ACTIVE SYSTEM MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH THE EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS OR EQUIPMENT IN THE FLOOR EMBEDDED IN CONCRETE OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT REUSED IN THIS PROJECT. IF REQUIRED BY THE LANDLORD OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF EMOL111ON PRIOR TO BID AND INCLUDE IN BID PROPOSAL. 3. ACTIVE LANDLORD OR OTHER TENANT SERVICES ENCOUNTERED IN WORK SHALL BE PROTECTED AND SUPPORTED. IF EXISTING SERVICES NOT ANTICIPATED REQUIRE RELOCATION, CONTACT HE TENANT'S CONSTRUCTION MANAGER IMMEDIATELY. ALL COSTS FOR REPAIR OF DAMAGES TO ACTIVE LANDLORD OR OTHER TENANT SERVICES DURING CONSTRUCTION SHALL BE PAID FOR BY THE CONTRACTOR CAUSING THE DAMAGE. 4. TIE-INS AND MODIFICATIONS TO EXISTING LANDLORD SERVICES MUST BE DONE WITH MINIMUM INTERRUPTION OF LANDLORD OPERATION AND DURING HOURS SPECIFIED BY THE LANDLORD. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING EXACT WORKING HOURS OF THIS WORK NH THE LANDLORD PRIOR TO SUBMITTING THEIR BID. THE CONTRACTOR SHALL INCLUDE IN THEIR BID ALL PREMIUM TIME REQUIRED TO PERFORM MODIFICATIONS DURING OTHER THAN NORMAL WORKING HOURS. ALL SUCH WORK MUST BE COORDINATED NH THE LANDLORD. 5. EQUIPMENT AND MATERIALS IN TRANSIT SHALL UTILIZE FREIGHT ELEVATOR OR STAIRS. SAID EQUIPMENT OR MATERIALS SHALL BE DISASSEMBLED AS REQUIRED TO MEET THE RESTRICTIONS IMPOSED BY THE BUILDING OR ITS COMPONENT CONSTRAINTS AND THEN REASSEMBLED IN THE NEW WORK AREA. 6. ALL WORK SHALL BE DONE WITH A MINIMUM OF NOISE AND DISTURBANCE TO BUSINESS ROUTINE. ALL WORK SCHEDULES SHALL BE COORDINATED WITH AND APPROVED BY, THE TENANTS CONSTRUCTION MANAGER. 7. SINCE THESE ARE SECURE FLOORS, ALL DELIVERIES WORKERS WORK OPERATORS REQUIRED BY THE CONTRACT ETC. RE Q OR FOR WORK PERFORMED IN ANY AREA OR SITE BUILDING SHALL BE IN STRICT CONFORMANCE TO THE RULES AND REGULATIONS OF THE OWNER. 8. CONTRACTOR SHALL PROTECT THEIR WORK AND EQUIPMENT FROM DAMAGE, ACCEPTANCE OF BUILDING BY OWNER AND ARCH TECT SHALLL BE REPLACEDRBYO RESPECTIVE CONTRACTOR AT NO CHARGE TO TENANT. 9. IT IS SPECIFICALLY THE INTENTION OF THIS SPECIFICATION TO HOLD THE CONTRACTOR RESPONSIBLE FOR ALL DAMAGE DONE TO ANY EXISTING FACILITIES, EQUIPMENT PAINTING, OR ARCHITECTURAL AND STRUCTURAL FEATURES OF THE BUILDING by EITHER THEIR OWN WORKMEN OR BY ANY OF THEIR SUBCONTRACTORS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE DONE BY THEIR OWN WORKMEN OR SUBCONTRACTORS AND THE OWNER AT THEIR DISCRETION, MAY WITHHOLD PAYMENTS EQUAL TO THE REASONABLE COST OF THE REPAIRS. 10. THIS CONTRACTOR OR THEIR WORKMEN SHALL NOT BE PERMITTED TO USE ANY PART OF THE EXISTING BUILDING AS A SHOP WITHOUT THE APPROVAL OF THE OWNER AND ARCHITECT. 11. WHERE HE WORK MAKES TEMPORARY SHUTDOWN OF SERVICES UNAVOIDABLE, THEY SHALL BE MADE AT NIGHT OR AT SUCH TIMES AS WILL CAUSE THE LEAST INTERFERENCE WITH THE ESTABLISHED OPERATING ROUTINE. 12. THIS CONTRACTOR SHALL ARRANGE THE WORK SO AS TO ASSURE THAT SERVICES WILL BE SHUT DOWN ONLY DURING THE TIME ACTUALLY REQUIRED TO MAKE THE NECESSARY CONNECTION TO THE EXISTING WORK. THIS CONTRACTOR SHALL GIVE AMPLE WRITTEN NOTICE IN ADVANCE TO THE OWNER OF ANY REQUIRED SHUT DOWN. MTRRENSCO CNXSHLL,BEPREUBWOPUREBEQUIPENFFOUSI�OTRACTAOTCtEDYTARALIINOY BOXING AS SOON AS DELIVERED TO THE SITE AND SHALL BE KEPT CLEAN AND DRY. THE MOTORS UNITS, FIXTURES FANS, DUCTWORK AND MOVING PARTS SHALL BE KEPT COVERED SO AS TO ELIMINATE DIRT DUST AND OTHER MATERIALS ENTERING THE PARTS DURING ERECTION AND CONSTRUCTION WORK ON THE BUILDING. SHOULD IT BE FOUND THAT ANY PARTS ARE DAMAGED DUE TO CARELESSNESS ON THE PART OF THE CONTRACTOR IN NOT PROVIDING PROPER PROTECTION, SUCH PART OR PARTS SHALL BE REPLACED BY HE CONTRACTOR AT THEIR OWN COST AND EXPENSE. ALL TEMPORARY DUCTS PIPING AT ALL STIMES '' SHALL BE PROPERLY PROTECTED WITH �l �l;;� :1►L�II yl�1l�Z�Z loll&, H. TRADE NAMES AND MANUFACTURERS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM STANDARD FOR THE BdSE BID. MANUFACTURERS CONSIDERED AS AN EQUIVALENT OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO REVIEW IN WRITING ANY UNAUTHORIZED EQUIPMENT SHALLABERSUBJOECT TOACCEPTANCE. REMOVALCAND REPLACEOMENT AT THE CONTRACTOR'S EXPENSE. I. SHOP DRAWINGS 1. SUBMIT THREE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR ALL EQUIPMENT AND DUCT FABRICATION DRAWINGS TO THE TENANT'S CONSTRUCTION MANAGER FOR REVIEW PRIOR TO ORDERING EQUIPMENT. SUBMISSIONS MUST BE EARLY ENOUGH TO ALLOW HE TENANT'S CONSTRUCTION MANAGER EIGHT WORKING DAYS FOR REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS USING HE MANUFACTURER'S LISTED ON THE DRAWINGS. SHOP DRAWINGS SHALL INCLUDE ALL DATA THAT PERTAINS TO THE REQUIREMENTS SET FORTH ON THE DRAWINGS AND IN THE SPECIFICATIONS. THE SUBMITTAL SHALL INCLUDE BUT NOT BE LIMITED TO CUTS OR CATALOGS INCLUDING DESCRIPTIVE LITERATURE AND CHARACTERISTICS OF EQUIPMENT SHALL SHOW MAJOR DIMENSIONS ROUGHING -IN DATA, CAPACITY CURVES PRESSURE DROPS CODE COMPLIANCE, I OTOR AND DRIVE DATA AND ELECTRICAL DATA. OBSERVE SPEbAL INSTRUCTIONS WHEN REQUIRED. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL AND SUBCONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS OR INDICATE WHERE EXCEPTIONS TAKE PLACE. LACK OF SUCH CONTRACTOR'S REVIEW WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY TENANT'S CONSTRUCTION MANAGER. ALL SHOP DRAWINGS MUST APPEAR IN THE OPERATION AND MAINTENANCE MANUALS LEFT ON SITE AT JOB COMPLETION. 2. TENANT'S CONSTRUCTION MANAGER'S OR ARCHITECT'S REVIEW OF SHOP DRAWINGS OR SCHEDULES SHALL NOT RELIEVE THE CONTRACTOR FROM THESHOPIDRAWINGSEFROMStHE CONSTRUOCTIO DOCUMENTDEFICIENCIES OR DEVIATIONS IN 3. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND / OR THEIR SUBCONTRACTORS TO FURNISH SHOP DRAWINGS AND SUBMITTALS ON ANY AND ALL EQUIPMENT QUIPME T�ONSTf�UCT1 PERS, CONTROLS ETC. TO THE ARCHITECT FOR THEIR REVIEW PRIOR J. RECORD DRAWINGS - (CONFIRM REQ'D WITH TENANT & LANDLORD) 1. THE CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS AND SPECIFICATIONS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS LOCATIONS OF CONCEALED PIPING VALVES AND DUCTS, REVISIONS ADDENDUM'S AND CHANGE ORDERS SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED LQUIPMENT SUBSTITUTIONS AND CONTRACTOR'S COORDINATION WITH OTHER TRADES AND EXACT ROUTING OF ALL SANITARY AND DOMESTIC WATER PIPING UNDER FLOOR. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS ANb CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. THE DRAWINGS ARE TO BE TURNED OVER TO HE TENANT. ' COE\:L1►11010w,":WIMN lit 1. THE MECHANICAL CONTRACTOR SHALL INCLUDE IN THE PROPOSAL A ONE YEAR GUARANTEE WARRANTY ON ALL EQUIPMENT MENT AND MATERIAL INSTALLED OR REFURBISHf'D ALL MATERIALS AND WORK UNDER THE CONTRACT AND SHALL MAKE MATEf�IAL OD OR ,EQUIPREPLACE NT WHICH MAT AY BEWDISCOVERED WITHIANY N EAEPER OD OFKi 2 MONTHS FROM THE DATE OF WRITTEN ACCEPTANCE OF THE INSTALLATION BY THE TENANT'S CONSTRUCTION MANAGER. IN CASE OF REPLACEMENT OR REPAIR OF EQUIPMENT DUE TO FAILURE WITHIN THE GUARANTEE PERIOD, HE GUARANTEE ON THAT PORTION OF WORK SHALL BE EXTENDED FOR A PERIOD OF 12 MONTHS FROM HE DATE OF SUCH REPLACEMENT OR REPAIR. THIS GUARANTEE, WARRANTY IS TO INCSATTISFACTLABOR R YOOPERAT ON NOR A TPERIOD* OF ONE YEAR TOMAINTAIN FROM SYSTEM DATE OF ACCEPTANCE OF HE SYSTEM BY HE TENANT. IT SHALL ALSO INCLUDE ONE SUMMER TO WINTER CHANGEOVER AN D ONE WINTER TO SUMMER CHANGEOVER, A NEW SET OF FILTERS AT THE TIME OF STARTUP AND TWELVE (12) MONTHLY FILTER CHANGES DURING THE FIRST YEAR. THE NORMAL PREVENTATIVE MAINTENANCE WORK SHALL BE PERFORMED AT THE TIME OF THE FILTER CHANGES. USE ONLY #40 PLEATED TYPE AIR FILTERS. �471:1(:nlTM10W.:1 1. ONE COPY OF EACH OPERATION AND MAINTENANCE MANUAL FOR ALL EQUIPMENT FURNISHED ON THE JOB SHALL BE PROVIDED TO THE TENANT BOUND TOGETHER IN A 3 INCH, THREE RING BINDER. THE BINDER SHALL INCLUDE BUT NOT BE LIMITED TO INSTALLATION, MAINTENANCE AND OPERATING INSTRUCTIONS, PAMPHLETS OR BROCHURES, REVIEWED SHOP DRAWINGS AND WARRANTIES OBTAINED FROM EACH MANUFACTURER OF PRINCIPAL ITEMS OF EQUIPMENT. M. SLEEVES 1. THE CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH ITS SURFACE EXCEPTT kLOOR EEVES OR PENEOTRATEDTHEAFLOOR, CUT U SHALL EXTEND XTEND 2 INCHES ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH APPROVED SEALANTS RATED FOR THE APPLICATION SO AS TO MAINTAIN THE FIRE RATING OF THE ASSEMBLY. CONFORM TO THE U.L. ASSEMBLY RATING OF THE FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SWOON EDGES. FOR OTHER THAN MASONRY IP NG RSLEEVES SHALL BE022 GAUGE GALVANIZED STEEEL FOR CONCEALED VERTICAL 4. DUCT SLEEVES SHALL BE MINIMUM 14 GAUGE STEEL. N. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS C-CLAMPS NH RETAINING CLIPS CHANNELS, HANGER RODS, ETC. NECESSARY FOR THE INSTALLATION OF WbRK. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK. DUCTWORK SHALL NOT BE SUPPORTED FROM ROOF DECKING AND/OR BRIDGING BUT SHALL BE SUSPENDED FROM THE TOP CHORD OF BAR JOISTS, STEEL OR OTPER STRUCTURE. DUCTWORK SHALL CLEAR ALL SPRINKLERS AND OTHER OBSTACLES AND SHALL BE HUNG AS HIGH AS POSSIBLE IN WORK AND STORAGE AREAS. WHERE INTERFERENCE'S OCCUR IN ORDER TO SUPPORT DUCTWORK OR PIPING THE CONT RACTOR MUST INSTALL TRAI'E ZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE REQUIREMENTS AND/OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6 INCH LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI -ELECTRICALLY SEPARATED FROM ONE ANOTHER. P. ACCESS DOORS 1. FURNISH STEEL ACCESS DOORS AND FRAMES MINIMUM 16 INCHES BY 20 INCHES OR AS REQUIRED FOR ADEQUATE ACCESS TO THE GENERAL CONTRACTOR FOR ALL LOCATIONS WHERE NECESSARY TO PROVIDE ACCESS TO CONCEALED VALVES AND OTHER EQUIPMENT REQUIRING SERVICE OR INSPECTION. LOCATION, TYPE SIZE AND NUMBER WILL BE DETERMINED BY THE CONTRACTOR AND APPROVED By THE TENANT CONSTRUCTION MANAGER TO SUIT EQUIPMENT REQUIREMENTS. GENERAL CONTRACTOR WILL INSTALL ACC ESS DOORS AND FRAMES. 2. ACCESS DOORS LOCATED IN FIRE -RATED WALLS, FLOORS, CEILING -FLOOR, OR CEILING ROOF ASSEMBLIES SHALL BE FIRE RATED, U.L. LISTED AND LABELED. 3. ACCESS DOORS SHALL BE FLUSH TYPE, MANUFACTURED FROM 14 GAUGE STEEL COMPLETE WITH FLUSH FLANGE TYPE FRAMES MANUFACTURED FROM 16 GAUGE STEEL, PROVIDED WITH ANCHORS. ACCESS DOORS SHALL BE SUITABLE FOR INSTALLATION IN WALL OR CEILING MATERIALS SHOWN IN ROOM FINISH SCHEDULES. PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, DAMPERS, FIRE DAMPERS EXPANSION JOINTS PULL BOXES SHOCK ABSORBERS DRAINS MOTORS, FANS, PUMPS AND ANY OTHER ITEM REQUIRING SERVICE. DOORt IN PLASTER OR CONCRETE SURFACES SHALL HAVE A RECESSED DOOR WITH CONCRETE OR PLASTER FACING. DOORS IN CARPETED OR TILED AREAS SHALL BE RECESSED WITH TILE FACING. NO ACCESS DOORS ARE REQUIRED IN 2' X 2' AND 2' X 4' LAY -IN ACOUSTIC TILE CEILING. PROVIDE COLORED PINS TO DENOTE ACCESS TILES. FURNISH SCREWDRIVER OPERATED,CWITHS FRAMES AND PCAM LTYYPEUCAYCH LWI4TH HEAD" STEEL STUD. DOORS SHALL BE NOT LESS THAN 12" X 12" FOR HAND ACCESS. DOORS IN WALLS AND CEILING SHALL BE PRIME COATED CARBON STEEL. FURNISH FIRE RATED DOORS FOR FIRE RATED CONSTRUCTION. RATING OF DOOR MUST BE SAME RATING AS CONSTRUCTION. Q. ELECTRIC MOTORS 1. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT, UNLESS HEY ARE FACTORY INSTALLED ON THE UNIT. ALL STARTERS AND ASSOCIATED WIRING AND SAFETY SWITCHES FOR SUCH MOTORS SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL SPECIFICATIONS. 2. DESIGN CONSTRUCTION AND PERFORMANCE CHARACTERISTICS OF MOTORS SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF LATEST NEMA ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL BE SUITABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10 PERCENT, 40 DEGREES C AMBIENT TEMPERATURE AND HAVE A SERVICE FACTOR OF NOT LESS THAN 1.15. R. LOW VOLTAGE (24 VOLT) WIRING 1. THE CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIRED FOR THEIR EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE THIS A COMPLETE FUNCTIONAL SYSTEM. 2. ALL WORK IS TO CONFORM TO THE ELECTRICAL SPECIFICATIONS AND THE REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 3. ANY CONDUIT REQUIRED BY CODE OR THE LANDLORD WILL BE INSTALLED BY THE ELECTRICAL SUBCONTRACTOR. 4. SMOKE DETECTORS AND REMOTE TEST STATION I. IONIZING TYPE ARE TO BE USED ON THE RETURN SIDE OF THE AHU AND PHOTO -TYPE ARE TO BE USED ON THE SUPPLY SIDE. ON ALL OTHER TYPES OF HVAC UNITS WHERE SMOKE DUCT DETECTORS ARE REQUIRED, USE FIELD INSTALLED IONIZING TYPE IN RETURN DUCTWORK AND PHOTO -TYPE ON THE SUPPLY LOCATED BEFORE HE FIRST TAKEOFF. ONCE ACTIVATED, THE SMOKE DETECTOR WILL SHUT DOWN HVAC UNIT. ii. SMOKE DETECTORS SHALL HAVE THEIR OWN REMOTE KEY TEST STATION SYSTEM WITH AUDIBLE AND VISUAL ALARM, SIMPLEX MODEL 4098-9842 OR APPROVED EQUIVALENT. ALARM TO HAVE CANDELA SETTING OF 75 AND A HIGH VOLUME HORN TONE SETTING. ALARM SYSTEM MAY BE DELETED WHERE NOT REQUIRED BY LANDLORD OR BY LOCAL CODE. A. HEATING, VENTILATION AND AIR CONDITIONING 1. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL MECHANICAL AND ELECTRICAL PLANS AND SPECIFICATIONS TO SEQUENCff, COORDINATE AND INTEGRATE THE VARIOUS ELEMENTS OF THE HVAC SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCE'S AND CONFLICTS. B. HVAC EQUIPMENT (REFER TO PLANS FOR SCHEDULE OF EQUIPMENT) 1. PRIMARY HVAC UNITS ARE TO BE AS SCHEDULED. EQUIVALENTS MAY BE SUBSTITUTED WITH WRITTEN APPROVAL ONLY. ALL COMPRESSORS ARE TO INCLUDE A 5 YEAR EXTENDED WARRANTY. 2. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT WITH ALL DEVICES, APPURTENANCES AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED. 3. EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. R CTIONS. ALL AIR CONDITIONING EQUIPMENT MUST HAVE A CONDENSATE DRAIN AND BE TRAPPED IN ACCORDANCE WITH MANUFACTURER'S DATA. SEE DRAWINGS FOR ADDITIONAL DETAILS. 4. SECONDARY DRAIN PANS ARE REQUIRED TO BE INSTALLED BENEATH ALL INDOOR AIR CONDITIONING EQUIPMENT NH THE EXCEPTION OF AIR TERMINAL BOXES. SECONDARY PANS ARE TO PROTECT ENTIRE UNIT. PROVIDE CONDENSATE PUMPS AS REQUIRED. CONDENSATE SHALL BE DIRECTED TO MOP SINK, LAVATORY TRAP OR OTHER APPROVED DRAIN. C. TOILET EXHAUST FANS 1. WHERE SHOWN ON DRAWINGS PROVIDE A TOILET EXHAUST FAN COMPLETE WITH GRAVITY BACKDRAFT DAMPER. ALL DUCTWORK, ROOF OPENINGS AND CAPS NECESSARY TO PROVIDE A COMPLETE EXHAUST SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR. REFER TO PLANS FOR APPLICABILITY. D. VIBRATION ISOLATION DEVICES 1 VIBRATING EQUIPMENT HUNG FROM STRUCTURE SHALL BE ISOLATED WITH RUBBER AND SPRING DEVICES. VIBRATING EQUIPMENT SUPPORTED FROM FLOOR OR DECK SHALL BE ISOLATED WITH HOUSED SPRING MOUNT DEVICES. 2. EXAMINE DEAD LOAD AND OPERATING LOAD CONDITIONS WHEN SELECTING DEVICES. ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOID "GROUNDING" THE ISOLATOR. 3. CHECK HANGER ROD SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVICE AND HE UPPER AND LOWER ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. 4. CONSULT MANUFACTURER FOR APPLICATION DATA. G. CURBS AND STEEL FRAMING FOR SUPPORT 1. THIS CONTRACTOR WILL PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING REQUIRED TO INSTALL ALL HVAC EQUIPMENT. CURBS SHALL BE A MINIMUM OF 14 INCHES HIGH AND OF THE SAME MANUFACTURER AS THE EQUIPMENT SUPPORTED. INSULATE UNDER THE COMPRESSOR SECTION TO PREVENT CONDENSATION. ALL CURBS MUST BE INSTALLED SO THAT THE TOP OF CURBS ARE "DEAD" LEVEL. ALL PENETRATIONS OF EXISTING STRUCTURE SHALL BE DONE IN ACCORDANCE WITH THE LANDLORD'S GUIDELINES AT THIS CONTRACTOR'S EXPENSE. ALL CONNECTIONS TO ROOFTOP EQUIPMENT SHALL BE INSIDE THE CURB (CONDENSATE DRAIN, POWER WIRING, CONTROL WIRING, ETC.). H. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED 1. NO DUCTWORK SHALL BE FABRICATED PRIOR TO APPROVAL BY HE TENANT'S CONSTRUCTION MANAGER. DEVIATIONS FROM DESIGN MUST BE APPROVED BY TENANT'S CONSTRUCTION MANAGER PRIOR TO FABRICATION OR INSTALLATION. ALL DUCT MAINS ARE TO BE RECTANGULAR. ALL DUCT BRANCHES TO DIFFUSERS ARE TO BE ROUND SPIRAL DUCT. 2. ALL DUCTWORK SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH SMACNA LOW VELOCITY AND "HVAC DUCT CONSTRUCTION STANDARDS MANUAL" LATEST EDITION AND ASHRAE USING PRIME SHEETS OF GALVANIZED STEEL. CONFORM TO THE REQUIREMENTS IN THE REFERENCED STANDARD FOR METAL THICKNESS, REINFORCING TYPES AND INTERVALS, TIE ROD APPLICATIONS AND JOINT TYPES AND INTERVALS. ALL SQUARE ELBOWS SHALL BE PROVIDED WITH DOUBLE WALLED VANES ON MAXIMUM 3" CENTERS. PROVIDE SEAL CLASS "C" ON ALL TRAVERSE JOINTS UNLESS SUPERSEDED BY MORE STRINGENT LOCAL CODES. ALL DUCT CONNECTIONS ARE TO BE RIGID AND LEAK FREE ASSEMBLIES. 3. DURING THE CONSTRUCTION PHASE OF THE PROJECT ANY DUCTWORK INSTALLED IS TO BE COMPLETELY SEALED UP OF ANY OPENINGS, EITHER AT THE BEGINNING OR END OF A DUCT RUN OR AT A BRANCH, COLLAR DIFFUSER OR REGISTER TO AVOID DIRT OR OTHER CONTAMINANTS FROM ENTERING THE SYSTEM. 4. EXCEPT WHERE OTHERWISE INDICATED, CONSTRUCT DUCT SYSTEMS TO 2 INCH WATER GAUGE PRESSURE CLASSIFICATION VERIFY WHETHER RETURN OR EXHAUST DUCT IS POSITIVE OR NEGATIVE PRESSURE). PRESSURE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING JOINTS AND APPLY SEALANTS AS REQUIRED TO FABRICATE A SYSTEM THAT DOES NOT EXCEED 5 PERCENT LEAKAGE OR LESS AS STATED BY PRESSURE CLASS RATINGS IN SMACNA STANDARDS. 5. AS A MINIMUM, CROSSBREAK ALL FLAT SURFACES OR REINFORCE WITH A BEAD APPROXIMATELY 3/8 INCH WIDE BY 3/16 INCH DEEP ON 12 INCH CENTERS TO PREVENT VIBRATIONS. 6. INSTALL RIGID ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA STANDARDS. NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY LANDLORD. 7. WHERE DUCTS PASS THROUGH ROOFS FLOORS AND FIRE RATED PARTITIONS, PROVIDE AS MINIMUM 1 1 /2 INCH BY 1 1 %2 INCH BY 1 /8 INCH STEEL ANGLE FRAMES AT EACH SIDE OF OPENING. THE ANNULAR SPACE BETWEEN DUCT AND ANGLE FRAMES SHALL BE CAULKED WITH SILICONE SEALANT OR FIREPROOFED AS REQUIRED BY THE ASSEMBLY FIRE RATING. CONTRACTOR TO PROVIDE FIRE OR COMBINATION FIRE / SMOKE DAMPERS AT EACH PENETRATION WHERE REQUIRED BY CODE. 8. ALL TRAVERSE JOINTS AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR TIGHT WITH DAP CIVIC DUCT SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTED WITH SHEET METAL SCREWS. 9. SOFT ELASTOMER BUTYL GASKETS WITH ADHESIVE BACKING SHALL BE USED TO SEAL FLANGED JOINTS. 10. DUCT TRANSITIONS SHALL NOT EXCEED 30 DEGREES SLOPE EXCEPT AS SPECIFICALLY NOTED OTHERWISE. 11. PROVIDE ACCESS TO ALL MOTORIZED DAMPERS FIRE DAMPERS FIRE SMOKE DAMPERS CONTROLS AND OTHER ITEMS IN DUCTWORK THAT REQUIRE SERVICE OR INSPECTIdN. IF THE ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA, IT MUST BE APPROVED BY THE TENANT'S CONSTRUCTION MANAGER PRIOR TO WITH PLASTER LAY-IN MAY BEAUSED RETURN CCAIRESS DIFFUSERS GRILLES AND REGISTERS 12. ALL BRANCHES AND TAKEOFFS SHALL BE EQUIPPED WITH MANUAL VOLUME CONTROLLING DEVICES HAVING AN INDICATING AND LOCKING DEVICE. I. FLEXIBLE CONNECTIONS 1. FLEXIBLE COLLARS SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT (FANS, ROOFTOP UNITS, WATER SOURCE HEAT PUMPS, AIR PROVIDE SPLEXIBLEOCONNECTIONSSWHEREEDUCTSNCROSSTBUILLDING CASINGS. 2. FLEXIBLE CONNECTIONS SHALL BE CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF FABRIC. PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF VIBRATION. 3. FLEXIBLE CONNECTIONS ARE TO BE RATED FOR THE OPERATING PRESSURE OF THE SYSTEM. 4. FINAL CONNECTIONS TO EXHAUST FAN(S) SHALL BE WITH A HEAVY AIRTIGHT ACID RESISTANT FIRE RETARDANT FIBERGLA S D NEOPRENE CONNECTOR, A MINIMUM OF SIX �6� INCHES IN LENGTH. THE CONNECTOR SHALL BE FASTENED TO EQUIPMENT AND DU WITH TWO FLEXIBLE REMOVABLE BRASS STRAPS OR ALTERNATE APPROVED METHOD. J. THERMOSTATS 1. MOUNT THERMOSTATS 4'-0" ADA COMPLYING1, THERMOSTAT SENSORS 5-0" ABOOPERATINGFLOORS AND SET INSTRUCTIONSTO TENANT RE RESLTATITEMPERATURE, ETC. TURN OVER 2. THERMOSTATS SHALL BE PROVIDED WITH KEY OPERATED SECURITY COVERS AND DESCRIPTIVE NAMEPLATES. K. FLEXIBLE AIR DUCT 1. FLEXIBLE DUCT FOR CONNECTIONS SHALL BE A FACTORY FABRICATED ASSEMBLBARRIER. YHEnININER SLEEEVEOF NSHALLINNER BE CONSTVE RUCTED OF A CONTINUAND AN UOUS MOISTURE COATED SPRING STEEL WIRE HELIX FUSED TO A CONTINUOUS LAYER OF FIBERGLASS IMPREGNATED AND COATED VINYL. A 1 1 /4" THICK LAYER OF INSULATING BLANKET OF FIBERGLASS WOOL SHALL ENCASE THE INNER SLEEVE AND BE SHEATHED WITH AN OUTER MOISTURE BARRIER OF A BIDIRECTIONAL REINFORCED METALIZED VAPOR BARRIER. THE FLEXIBLE DUCT SHALL BE RATED FOR A MAXIMUM WORKING VELOCITY OF 6000 FPM AND SHALL BE LISTED BY THE UNDERWRITERS LABORATORIES UNDER THEIR UL-181 STANDARDS AS A CLASS 1 DUCT AND SHALL COMPLY WITH NFPA STANDARD - 90A. THE FLEXIBLE DUCT SHALL BE THERMAFLEX M-KC OR APPROVED EQUIVALENT. FLEXIBLE DUCT SHALL ROUTE FROM SHEET METAL DUCTWORK TO CEILING DIFFUSERS ONLY. THERE SHALL BE NO EXPOSED FLEXIBLE DUCT. 2. FLEXIBLE AIR DUCT MAY ONLY BE USED IN VERTICAL APPLICATIONS WITH PRIOR APPROVAL FROM THE TENANT'S CONSTRUCTION MANAGER. 3. FLEXIBLE DUCT SHALL NOT EXTEND OVER 5 FEET IN LENGTH AT ANY ONE LOCATION. L. SUPPLY AND RETURN AIR TAKEOFF FITTINGS 1. RECTANGULAR DUCT A. PROVIDE 45 DEGREE RECTANGULAR TAKEOFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. 2. SPIRAL DUCT A. PROVIDE SADDLE OR DIRECT CONNECTION OF A BRANCH DUCT INTO A LARGER DUCT. THE DIAMETER OF THE BRANCH SHALL NOT EXCEED TWO THIRDS OF THE DIAMETER OF THE MAIN. PROTRUSIONS INTO THE MAIN ARE NOT ALLOWED. N. DAMPERS 1. Ra=MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. 2. WHERE ACCESS TO BALANCING DAMPER IS RESTRICTED OR IN AREAS WITH SHEET ROCK CEILINGS YOUN G REGULATORS SHALL LL BE USED. 3. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR AND RELIEF AIR DUCTS ARE TO BE OPPOSED BLADE E. ALL RECTANGULAR DAMPERS IN RETURN AIR DUCTS TO BE PARALLEL BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. 4. ALL MOTORIZED DAMPERS NOT FURNISHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPERS. 0. DIFFUSERS, GRILLES AND REGISTERS 1. PROVIDE DIFFUSERS, GRILLES AND REGISTERS AS SCHEDULED. DEVICES TO BE COMPLETE WITH FRAMES AND ALL ACCESSORIES. ALL DIFFUSERS GRILLES AND REGISTERS IN SHEET ROCK CEILINGS TO BE PROVIDED WITH PLASTER FRAMES. FINISH TO BE COORDINATED NH INTERIOR FINISHES. 2. INSTALL ALL AIR DEVICES AS LOCATED ON THE ARCHITECTURAL REFLECTED CEILING PLAN OR THE MECHANICAL PLAN. P. DUCTWORK INSULATION 1. ALL NEW SUPPLY AND RETURN AIR DUCTWORK WITHIN 10' OF HVAC UNIT SHALL BE ACOUSTICALLY LINED. DUCT SIZES SHOWN ON THE DRAWING ARE INTERNAL FREE AREA SIZES. INTERNAL LINER SHALL BE 1 V2" THICK DUCT LINER EQUIVALENT TO JOHNS MANVILLE "PERMACOTE LINACOUSTIC f R VALUE" = 6.3) AND SHALL BE APPLIED TO HE DUCTWORK WITH FIRE RESISTIVE ADHESIVES AND CADMIUM OR COPPER PLATED MECHANICAL FASTENERS. 2. ALL OUTSIDE AIR AND UNEXPOSED DUCTWORK WITHIN BUILDING, EXCEPT WHERE ACOUSTICALLY LINED, SHALL HAVE 2 INCH, FIBERGLASS DUCT WRAP INSULATION WITH FSK FACING EQUIVALENT TO JOHNS MANVILLE "MICROLITE XG TYPE 75" (INSTALLED "R VALUE" = 5.6). 3. LEADING EDGES OF DUCT INSULATION SHALL BE OVERLAPPED BY ADJOINING INSULATION FOR 6" MINIMUM AND THEN SEALED WITH FOIL VAPOR BARRIER ADHESIVE AND DUCT MASTIC SO THAT NO FIBERGLASS INSULATION IS VISIBLE. 4. ALL INSULATION ON EXISTING PIPING OR DUCTS THAT IS WETTED, DAMAGED, DISTURBED OR REMOVED SHALL BE REPLACED. 5. INSTALL INSULATION PRODUCTS IN ACCORDANCE NH MANUFACTURER'S WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 6. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING OF NO HIGHER THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM C 411 OR AS REQUIRED BY LOCAL CODES. 7. NOT REQ'D A. SERVICE: RECTANGULAR SUPPLY -AIR AND RETURN -AIR DUCTS. 1. MATERIAL: INSULATION BOARD, 6 PSF MINIMUM AND PLAIN FACING. 2. THICKNESS: 2 INCHES. 3. NUMBER OF LAYERS: TWO. TOTAL THICKNESS = 4" 4. VAPOR RETARDER REQUIRED: YES. A. INORGANIC GLASS FIBERS PREFORMED AND BONDED BY THERMOSETTING RESIN. 1. MUST COMPLY NTH ROQINUINSULATION APPROVED EUVALENt. A. INSULATION INSTALLED OUTDOORS: FLAME SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPED RATING OF 50 OR LESS. B. APPLY INSULATION AS FOLLOWS: A. APPLY TWO -LAYER INSULATION WITH JOINTS TIGHTLY BUTTED AND STAGGERED AT LEAST 3 INCHES. SECURE LAYERS WITH ADHESIVE, MECHANICAL FASTENERS OR BANDING. FASTENERS SHALL BE LOCATED A MAXIMUM OF 3" FROM EACH EDGE AND NO GREATER THAN 12" APART. B. ON EXPOSED APPLICATIONS FINISH INSULATION WITH A SKIM COAT OF INSULATION. WHENDDRY,LIC-SETTINd CEMENTAPPLY FLOOD COAT TOOF LAGGIING ADHESIVE LANSURFAE OF D PRESS ON ONE LAYER OF GLASS CLOTH OR TAPE. OVERLAP EDGES AT LEAST 1 INCH (25 MM). APPLY FINISH COAT OF LAGGING ADHESIVE OVER GLASS CLOTHOR TAPE. THIN H FINISH COAT TO ACHIEVE SMOOTH FINISH. OUTDOOR JACKET: POLYGUARD PRODUCTS, INC. 'ALUMAGUARD 60' OR MFM BUILDING PRODUCTS CORP. 'FLEXCLAD 400". Q. SYSTEM CLEANOUT 1. UPON COMPLETION OF INSTALLATION, CLEAN ENTIRE SYSTEM BEFORE INSTALLING AIR OUTLETS. CONTRACTOR TO PROVIDE A CERTIFICATION THAT CLEANING WAS ACCOMPLISHED PRIOR TO PROJECT CLOSEOUT. 2. FILTERS MUST BE IN UNITS AT ANY TIME FANS ARE OPERATED. R. SYSTEM TESTING, ADJUSTING AND BALANCING 1. TESTING ADJUSTING AND BALANCING OF ALL WORK SHALL BE COMPLETED BY AN INDEPENDENT CONTRACTOR WHO IS CURRENTLY LICENSED BY THE ASSOCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB_ ). NO OTHER BALANCE REPORTS WILL BE REVIEWED OR ACCEPTED. ALL BALANCING WORK MUST BE COMPLETE AND DONE IN ACCORDANCE WITH THE MOST RECENT STANDARDS OF THEIR SOCIETY. PAYMENT OF ALL COSTS FOR TESTING SHALL BE MADE BY HE HVAC CONTRACTOR. 2. THE CONTRACTOR SHALL INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANCING. THE COMPLETE AIR BALANCE SHALL TAKE PLACE WITH OUTSIDE AIR DAMPERS IN MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN PLUS OR MINUS 5 PERCENT PULLEYS OR ITHEEADDITIONEOFF DAMPERSAREQUIRQEDIT O ACHIEVE SPECIFIEDVFLbBELTS, RATES SHALL BE PROVIDED BY THE HVAC CONTRACTOR WITH NO ADDITIONAL COST TO HE TENANT. 4. THE BALANCE REPORT SHALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: AAABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. B INSTRUMENTATION LIST WITH LAST CALIBRATION DATES. C MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. D AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS M ASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNITS. E MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE R ADINGS FOR EACH LEG. F MOTOR AND FAN RPM, SHEAVE SIZES AND BELT SIZES AND LENGTHS. G OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. H WATER BALANCE DATA INCLUDING GPM WITH INLET AND OUTLET TEMPERATURE A D PRESSURE READINGS. I) MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J) FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED . K) IN EXED PLAN WITH DIFFUSER AND RETURN LOCATIONS. 5. ALL CONTROL SEQUENCES SHALL BE TESTED AND OPERATING STATUS RECORDED IN THE REPORT. 6. THREE COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED THROUGH THE GENERAL CONTRACTOR TO HE TENANT'S CONSTRUCTION MANAGER FOR REVIEW AND COMMENT. 7. THE BALANCING CONTRACTOR SHALL PERFORM ALL APPLICABLE TESTING AND BALANCING FUNCTIONS REQUIRED FOR THE SYSTEM DESIGNED IN THESE DRAWINGS. THE BALANCING CONTRACTOR SHALL RECHECK ANY ITEMS THAT HE TENANT DEEMS NECESSARY AT NO ADDITIONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OPERATION AND MAINTENANCE MANUAL. S. FINAL HVAC INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE THE TENANT SHALL HAVE THE RIGHT TO HAVE AN INDEPENDENT HVAC CONTRACTOR INSPECT THE FINISHED HVAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE Td BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATIONS REQUIREMENTS AT NO ADDITIONAL COST TO HE TENANT. T. INDOOR AIR QUALITY 1. NO ANALYSIS HAS BEEN MADE NH REGARD TO SOURCES OR POTENTIAL SOURCES OF INDOOR OR OUTDOOR AIR CONTAMINANTS OR LEVELS OF CONTAMINATION. 2. IT IS THE RESPONSIBILITY OF THE GENERAL AND MECHANICAL CONTRACTOR TO FORETENISUNFIDRNRCTTONTS IF ANY SOURCE OR POTENTIAL SOURCE IIDENTIFIED. 3. PRIOR TO ENCLOSING SPACES SUCH AS PLUMBING CHASES, AIR SHAFTS AND RETURN AIR PLENUMS CLEAN ALL AREAS THOROUGHLY. THE CONTRACTOR SHALL GUARANTEE THAT THE PLENUM CHAMBER USED FOR RECIRCULATING OF AIR WILL BE OF TIGHT CONSTRUCTION AND THAT ALL SOURCES OF CONTAMINATION FROM TRAPS, WILL BE ENCLOSED SOOTHAT NO CbNTAMINATEDI AIR WILLS BE RECIIRCULATEED. 4. PRIOR TO COMMENCING CONSTRUCTION ACTIVITIES SHUT OFF THE HVAC SYSTEM, BLOCK OFF ALL AIR GRILLS DIFFUSERS AND OTHER OPENINGS OUTSIDE THE IMMEDIATE CONSTRUCTION AREA. OPENINGS TO ADJACENT TENANT SPACES SHALL BE COVERED WITH FILTER MEDIA TO PREVENT DUST AND OTHER AIRBORNE CONTAMINANTS FROM PASSING TO ADJOINING SPACES. 5. CONTRACTOR TO INSTALL TEMPORARY EXH AUST SYSTEM TO VENTILATE CONSTRUCTION SITE AND KEEP SITE UNDER SLIGHT NEGATIVE PRESSURE DURING ALL HOURS OF CONSTRUCTION, EVEN IF AFTER NORMAL BUSINESS HOURS. 6. CONTRACTOR TO INSTALL TEMPORARY BARRIERS TO PROTECT ADJACENT SPACES FROM DUST PARTICULATES, VAPORS AND NOISE. WHERE TEMPORARY BARRIERS ARE INSTALLED ALWAYS MAINTAIN FIRE EXITS AND EXITWAYS. ®� �g 0, 3 , / ; 0 ,\ v 11 I 11 �. ,i �> . ,_ it It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. I- a 0 0- I- z w J U ao (10 z 0 IF- > z w w c�.- M :2 ,,,� 0 U LLI V) V) Ld I- Q 0 CL 0 c ca c 0 L co J N N c co 9, U_ 0 ' c2(1)0 CO U o e (C!a 8 0 aa) c o � Y z 'vrn o 0 w N rn r- rn Z� Q a) I 0 'U, �a, 3W 0� N WC � LLU) Q a.- L_ L _j o Ill U Q.I� O 3 H ir O 0 3 3 ro JI- W >` o 0a,(0N . `Z c °' Q a co 0 N 6;M .8 " M Kj Z 0 or,r`? E 3: c v a � or�, `o vZ� coo-_ rn -103 a r PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG MECHANICAL SPECIFICATIONS SHEET NO. M 0 . 1 OF P40 GENERAL NOTES A. CONTRACTOR SHALL VERIFY ALL CONDITIONS & �Q 2 2.5 DIMENSIONS AT THE JOB SITE AND NOTIFY THE z ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS, OR DISCREPANCIES BEFORE BEGINNING ANY WORK. �� 92168 B. MECHANICAL CONTRACTOR SHALL COORDINATE THE �V .� REQUIRED VOLTAGE OF THE ROOF TOP UNITS WITH G�►� ELECTRICAL CONTRACTOR PRIOR TO ORDERING. PRODUCT €D AT' DATA SHALL BE SUBMITTED TO TUESDAY MORNING'S 7 20 20i AUTHORIZED REPRESENTATIVE FOR APPROVAL, PRIOR TO ORDERING. / C. SUPPLY AND RETURN GRILLE FACES AND TRIM COLOR Lt SHALL MATCH CEILING COLOR. D. PROVIDE CONICAL SPIN IN FITTING WITH INTEGRAL VOLUME � I � DAMPERS AT EACH TAP. I E. ALL SIDEWALL SUPPLY DIFFUSER VANES ARE TO BE TURNED DOWN 35 DEGREES. STOCKROOM F. FLEXIBLE PORTIONS OF DUCT ARE NOT TO EXCEED 6'-0" j 102 f IN OVERALL LENGTH. G. ALL EXPOSED DUCTWORK AREA SHALL BE INSULATED DUCT. NO EXCEPTIONS OR ALTERNATIVES. H. INSTALL NEW CLEANABLE MERV 8 AIR FILTERS UPON TURN OVER TO OWNER. It is a violation of the law for any person, unless acting under V the direction of a licensed I Architect. Engineer or Land FI ING KEYED NOTES. Surveyor, to alter an Item in any way. Plans, maps, specifications, studies, and ROM 1. FULL SIZE EXHAUST DUCT. CONNECT BACK TO THE NEAREST reports not containing a red ink seal imprint on the cover sheet 104 EXISTING SANITARY VENT. EXHAUST FAN TO TIE INTO OCCUPANCY accompanied by an original signature by the licensed j SENSORS. professional may have been 1 ( 2• UNDER CUT DOOR 1 /2" fraudulently altered and shall not be considered an original copy. Copyright Protected 2018. 3. CONNECT NEW SUPPLY DUCT TO EXISTING. VERIFY EXACT LOCATION Larson Design Group. 4 Ll IN FIELD. 5 4. EXISTING SUPPLY DIFFUSER TO REMAIN. CLEAN AS REQUIRED. RESTROOM FI NG 5. EXISTING EXHAUST FAN DIFFUSER TO REMAIN. CLEAN AS REQUIRED. 106 a R��M 105 Q 66 3 J 75 1 g"0 � Q / 0 Q 6� I E1 �1 OFFICE I) 103 a o �5 A 6 fi U w 50 1 I o \ 2 w R 6x4 i w cn - RESTROOM SALES Q 0 � 107 101 w 0 0 \ H r 0 r o z — — — n 0 `Ln V - O 1 r N E2 C, 0 MECHANICAL PLAN m 0 1 0 fr E �a 0 O c M o rno rn Nez LU rn Q N (D 'v1 00 N 3 W U s V) W C O LL J 1� ■ U N � WV Qo O3 3 p �c o 3 J Uli�c0oC4 W C 0Q rn U .5L-dNCn M Kj Z � � p�I'7 �"Oo �0 Z 0 to Np o N o = 3:: a. PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG MECHANICAL PLAN SHEET NO. M1.0 SYMBOL LEGEND SYMBOL DISCRIPTION (TYPE NECK) (CFM QTY) DIFFUSER TABLE SUPPLY AIR DIFFUSER (12x12) EXISTING AIR DIFFUSER —i BALANCING DAMPER EXHAUST AIR GRILL (12x12) EXISTING EXHAUST AIR GRILL EXHAUST FAN SCHEDULE MARK MANUFACTURER MODEL # FAN ELECTRICAL WEIGHT NOTES/ CFM (TOTAL) T.S.P. ("WC) HP V-PH-CY MCA MOCP (LBS) ACCESSORIES EF-1 GREENHECK GC-168 150 0.25 129W 120-1 1.0 15 - 1,2,3 NOTES: 1. RESTROOM FAN SHALL BE INTERLOCKED WITH RESTROOM LIGHTS BY RELAY SWITCH INSTALLED BY THE ELECTRICAL CONTRACTOR. 2. EXHAUST FANS SHALL HAVE GRAVITY BACKDRAFT DAMPERS AND INSECT SCREENS 3. OVERALL SYSTEM STATIC PRESSURE SHALL NOT EXCEED THOSE LISTED FOR EACH FAN UNIT. AIR DISTRIBUTION SCHEDULE MARK MANUFACTURER MODEL # DESCRIPTION SIZE DEFLECTION BORDER COLOR REMARKS A TITUS TMS SUPPLY DIFFUSER 12x12 4—WAY LAY —IN WHITE 2 B TITUS 50F EXHAUST GRILLE 12x12 EGG GRATE LAY —IN WHITE 1 NOTE: 1 BUTTERFLY DAMPER TITUS AG-85 2 OPPOSED BLADE DAMPER TITUS AG-15—AA. •�� OF PL o GENERAL REQUIREMENTS A. GENERAL 1. CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY SITE ENGINEERS AND/OR OWNER. 2. VISIT SITE, CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. 3. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY ADJUSTED. 4. CONTRACTOR SHALL PROVIDE HIS OWN CLEAN-UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH DAILY. 5. CONTRACTOR SHALL PROTECT HIS WORK, HIS EXISTING AND ADJACENT PROPERTY AGAINST WEATHER. 6. CONTRACTOR SHALL PROTECT HIS WORK, MATERIALS, APPARATUS AND FIXTURES FROM DAMAGE. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, SHALL BE REMOVED AND REPLACED WITH NEW MATERIAL AT THE CONTRACTOR'S EXPENSE. 7. ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S PERMISSION FOR ANY SERVICE SHUTDOWNS. 8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF CONSTRUCTION AND THE SAFETY OF WORKMEN. 9. NO PIPING, DUCTWORK, WIRING, ETC. SHALL BE INSTALLED OR ROUTED ABOVE ELECTRICAL PANELS AND EQUIPMENT. 10. THE CONTRACTOR SHALL COORDINATE AND OBTAIN A WRITTEN APPROVAL IDENTIFYING THE ELECTRICAL CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING OF EQUIPMENT. NO ADDITIONAL PAYMENT WILL BE MADE FOR LACK OF CONTRACTOR COORDINATION OF ELECTRICAL CHARACTERISTICS. 11. DURING CONSTRUCTION THE CONTRACTOR MAY UNCOVER AN EXISTING CONDITION THAT WILL HAVE TO BE MODIFIED. ANY SUCH WORK WHICH COMES UNDER THE JURISDICTION OF THIS CONTRACTOR SHALL BE DONE BY THIS CONTRACTOR WITHOUT EXTRA COST TO THE OWNER, AS THOUGH FULLY DETAILED ON PLANS AND/OR DESCRIBED IN THE SPECIFICATIONS. 12. ALL DIMENSIONS, MEASUREMENTS AND PROJECT CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR. REFER ALL DIFFERENCES, IN WRITING, TO THE OWNER'S REPRESENTATIVE FOR CONSIDERATION PRIOR TO PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BEAR THE COST OF RECTIFYING WORK NOT APPROVED BY THE OWNER'S REPRESENTATIVE, CAUSED BY LACK OF COORDINATION AND OR NOTIFICATION. 13. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE WITH LOCAL CODE REQUIREMENTS, OTHER SPECIFICATION SECTION REQUIREMENTS, AND MANUFACTURER RECOMMENDATIONS. B. CODES, PERMITS, STANDARDS AND REGULATIONS 1. CONFORM TO ALL APPLICABLE CODES (LOCAL, STATE, NATIONAL CODES, NFPA, OSHA, ETC.). GOVERNMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND APPLICABLE STANDARDS. 2. OBTAIN PERMITS AND PAY ALL FEES, ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. C. DRAWINGS 1. THE SYSTEMS AS SHOWN ON PLUMBING DRAWINGS ARE DIAGRAMMATIC. CONFIRM ALL DIMENSIONS BY FIELD MEASUREMENT. 2. THE EXACT LOCATIONS FOR FIXTURES, EQUIPMENT AND PIPING WHICH IS NOT COVERED BY DRAWINGS, SHALL BE OBTAINED FROM THE SITE ENGINEERS OR HIS REPRESENTATIVE IN THE FIELD AND THE WORK SHALL BE LAID OUT ACCORDINGLY. D. BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS. 1. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE OF DEFECTS AND U.L. LABELED. 2. BASE BID MANUFACTURERS ARE INCLUDED IN THE SPECIFICATIONS OR LISTED IN THE NAME OR MAKE OF ANY ARTICLE, DEVICE, MATERIAL, FORM OF CONSTRUCTION, FIXTURE, ETC. STATED IN THIS SPECIFICATIONS, WHETHER OR NOT THE WORDS "OR APPROVED EQUAL" ARE USED, SHALL BE KNOWN AS A "STANDARD". 3. ALL PROPOSALS SHALL BE BASED ON "STANDARDS" SPECIFIED. 4. THE EQUIPMENT SCHEDULES ON THE DRAWINGS INDICATE MANUFACTURERS EQUIPMENT MODEL NUMBERS THAT THIS DESIGN HAS BEEN BASED ON. THE USE OF OTHER MANUFACTURES EQUIPMENT THAT IS LISTED AS ACCEPTABLE ALTERNATES AND REFLECTS ANY ADDITIONAL COST OF SUCH CHANGES SHALL BE PAID BY THE CONTRACTOR. 5. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS SUBMITTED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO EVALUATE IT AND CERTIFY THAT THE SUBSTITUTION IS EQUIVALENT IN ALL RESPECTS TO THE BASE SPECIFICATIONS. 6. COORDINATE ALL APPROVED SUBSTITUTIONS. ANY COSTS RESULTING FROM SUBSTITUTION SHALL BE THE RESPONSIBILITY OF AND PAID FOR BY THE CONTRACTOR. APPROVED SHOP DRAWINGS DO NOT ABSOLVE THIS CONTRACTOR FROM THIS RESPONSIBILITY. E. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THIS CONFORM THESE REQUIREMENTS PRIOR TO STARTING WORK. F. WARRANTY 1. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR (1) YEAR FROM DATE OF ACCEPTANCE. 2. EXTEND ALL MANUFACTURERS' WARRANTIES TO OWNER. 3. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. IN THE CASE OF REPLACEMENT OR REPAIR DUE TO FAILURE WITHIN THE WARRANTY PERIOD, THE WARRANTY ON THAT PORTION OF THE WORK SHALL BE EXTENDED FOR A MINIMUM PERIOD OF ONE (1) YEAR FROM THE DATE OF SUCH REPLACEMENT OR REPAIR. G. SHOP DRAWING SUBMITTALS 1. SUBMIT SHOP DRAWINGS FOR PLUMBING SYSTEMS, INCLUDING BUT NOT LIMITED TO FIXTURES AND EQUIPMENT WITH ADEQUATE DETAILS AND SCALES TO CLEARLY SHOW CONSTRUCTION. INDICATE THE OPERATING CHARACTERISTICS FOR EACH REQUIRED ITEM. CLEARLY IDENTIFY EACH ITEM ON THE SUBMITTAL AS TO MARK, LOCATION AND USE, USING SAME IDENTIFICATION AS PROVIDED ON THE CONSTRUCTION DOCUMENTS. 2. CONTRACTOR SHALL REVIEW AND INDICATE HIS APPROVAL OF EACH SHOP DRAWINGS PRIOR TO SUBMITTAL FOR REVIEW. SHOP DRAWINGS WILL NOT BE REVIEWED BY THE ENGINEER UNLESS THE CONTRACTOR'S APPROVAL IS NOTED. DO NOT START WORK OR FABRICATION UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER AND RETURNED TO THE CONTRACTOR. 3. SUBMITTALS WILL BE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND NOT FOR DIMENSIONS OR QUANTITIES. THE SUBMITTAL REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR PURCHASE OF ANY ITEM IN FULL COMPLIANCE WITH THE CONTRACT DOCUMENTS OR ITS COMPLETE AND PROPER INSTALLATION. 4. WHERE SUBMITTALS VARY FROM THE CONTRACT REQUIREMENTS, THE CONTRACTOR SHALL CLEARLY INDICATE ON SUBMITTAL OR ACCOMPANYING DOCUMENTS THE NATURE AND REASON FOR THE VARIATIONS. 5. EACH MANUFACTURER OR HIS REPRESENTATIVE MUST CHECK THE APPLICATION OF HIS EQUIPMENT AND CERTIFY AT TIME OF SHOP DRAWING SUBMITTAL THAT THE EQUIPMENT SPECIFIED HAS BEEN PROPERLY APPLIED AND CAN BE INSTALLED, SERVICED AND MAINTAINED WHERE INDICATED ON THE DRAWINGS. ADVISE ENGINEER IN WRITING WITH SUBMITTAL DRAWINGS OF ANY POTENTIAL PROBLEMS. THE MANUFACTURER SHALL BE RESPONSIBLE FOR ANY CHANGES THAT MIGHT BE NECESSARY BECAUSE OF PHYSICAL CHARACTERISTICS OF EQUIPMENT THAT HAVE NOT BEEN CALLED TO THE ENGINEER'S ATTENTION AT THE TIME OF SUBMITTAL. BASIC MATERIALS AND METHODS A. GENERAL 1. THIS SECTION INCLUDES BASIC PLUMBING MATERIALS AND METHODS TO COMPLEMENT OTHER SECTIONS IN THIS SPECIFICATION AND REQUIREMENTS INDICATED ON THE MECHANICAL DRAWINGS. B. SUPPORTS AND HANGERS 1. INSTALL HANGERS, SUPPORTS, CLAMPS AND ATTACHMENTS AS REQUIRED TO PROPERLY SUPPORT PIPING FROM BUILDING STRUCTURE. THE INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF MSS SP-69 AND SP-89. C. ESCUTCHEONS 1. FIT ALL PIPE PASSING THROUGH WALLS, FLOORS OR CEILINGS IN FINISHED ROOMS WITH STEEL OR BRASS ESCUTCHEONS. WHERE SURFACE IS TO RECEIVE A PAINT FINISH, MAKE ESCUTCHEONS PRIME PAINTED; OTHERWISE MAKE ESCUTCHEONS NICKEL OR CHROME PLATED. WHERE PIPING IS INSULATED, FIT ESCUTCHEONS OUTSIDE INSULATION. D. IDENTIFYING DEVICES AND LABELS 1. PROVIDE METAL EQUIPMENT NAMEPLATES PERMANENTLY FASTENED TO EQUIPMENT WITH PERATIONAL DATA ENGRAVED OR STAMPED. 2. IDENTIFY ALL PIPES AND VALVES UNEXPOSED AREAS, AND ACCESSIBLE CEILINGS AND SHAFTS. 3. COLOR CODE IDENTIFICATION BANDS OR MARKER BACKGROUNDS TO IDENTIFY CONTENTS OF PIPE AND DIRECTION OF FLOW LOCATED NEAR EACH VALVE AND FITTING, ON BOTH SIDES OF PIPE PASSING THROUGH WALLS AND ON LONG RUNS AT NOT OVER 20 FOOT INTERVALS. E. CUTTING, PATCHING AND DRILLING 1. PATCH AND FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT, DAMAGED OR MODIFIED AS A RESULT OF THE INSTALLATION OF THE MECHANICAL SYSTEMS. 2. EXACT LOCATION OF ROOF TOP MECHANICAL UNITS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER. CONTRACTOR SHALL FURNISH AND INSTALL ALL SUPPLEMENTAL SUPPORT STEEL FOR EQUIPMENT AND ROOF PENETRATIONS AFTER APPROVAL OF STRUCTURAL ENGINEER. INSULATION A. PLUMBING INSULATION (AS MANUFACTURED BY OWENS CORNING, KNAUF, SCHULLER OR CERTAINTEED) 1.INSULATE ALL ABOVE GRADE HOT AND COLD WATER PIPING WITH MOLDED FIBER GLASS HAVING AN ALL SERVICE JACKET. B. INSULATION THICKNESS SCHEDULE: 1) LESS THAN 2" DIAMETER PIPE: 1" THICK-HW ANDZ' THICK-CW; 2) 2"-8" DIAMETER PIPE: 1-1/2" THICK. 1.INSULATE ALL ABOVE -GRADE, HORIZONTAL RAIN CONDUCTORS AND ROOF DRAIN SUMPS WITH ONE (1) INCH THICK MOLDED FIBER GLASS HAVING TYPE ASJ JACKET AND MANUFACTURED BY OWENS-CORNING FIBERGLASS COMPANY. 2.INCLUDE INSULATION OF FITTINGS AND VALVES. KEEP VAPOR BARRIERS INTACT. APPLY TO MANUFACTURER'S RECOMMENDATIONS. PIPING AND VALVES A. GENERAL 1. LABEL ALL PIPING AND SHOW DIRECTION OF FLOW EVERY 20 FEET ON CENTER. B. CONNECTIONS TO EQUIPMENT 1. PROVIDE VALVED WATER CONNECTION FOR EQUIPMENT. 2.INCLUDE ACCESSORIES REQUIRED BY CODE, DRAWING OR MANUFACTURER'S INSTRUCTIONS. C. SANITARY AND STORM SEWERS 1. PVC PIPING SHALL NOT BE INSTALLED UNLESS PERMITTED BY CODE. 2. SANITARY/STORM SEWER AND VENT MATERIAL SHALL BE AS FOLLOWS: 3. AS PART OF THE FINAL INSPECTION PROCESS, THE GENERAL CONTRACTOR SHALL SCHEDULE AND PAY FOR A COMPLETE SEWER LINE VIDEO INSPECTION. PROVIDE A DVD COPY OF THE ENTIRE VIDEO INSPECTION TO THE OWNER. D. ABOVE GRADE SANITARY/STORM SEWER AND VENT MATERIAL SHALL BE AS FOLLOWS: (EXISTING TIE-IN FOR ROOF DRAIN IS SCH 40 PVC) 1. NO -HUB CAST IRON PIPE CISPI 1-301-78. 2. PVC-DWV PLASTIC ASTM D1785 WITH ASTM D2665 DWV SOLVENT WELD SOCKET FITTINGS. 3. SCHEDULE 40 GALVANIZED STEEL PIPE, ASTM A120-83 WITH CAST IRON SCREWED FITTINGS ANSI B16.22 1983. E. SITE STORM AND SANITARY SEWERS 1. UP TO 15" - PVC PLASTIC ASTM D3034 SDR 35 WITH ASTM D3212 GASKET JOINTS. F. DOMESTIC WATER PIPING 1. INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL FITTINGS, VALVES, HANGERS AND OTHER ACCESSORIES INCLUDING WATER METER AND BACKFLOW PREVENTER. EXTEND DOMESTIC WATER PIPING TO ALL FIXTURES AND EQUIPMENT REQUIRED FOR COMPLETE INSTALLATION. 1. INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FOR ISOLATION OF FIXTURES AND EQUIPMENT. VALVES TO BE FULLY COMPATIBLE WITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO, CRANE OR MILWAUKEE. INCLUDE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE. 2. DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: a. ABOVE GRADE - TYPE "L" HARD COPPER ASTM B88-832 WITH WROUGHT COPPER FITTINGS ASTM B16.22 1980 AND NON -LEAD OR ANTIMONY SOLDER JOINTS. b. BELOW GRADE - TYPE "K" SOFT COPPER WITHOUT JOINTS. C. FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. d. DOMESTIC HOT AND COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL NOT BECOME EMBEDDED IN THE FLOOR SLAB. 4. ALL PIPING UNDER CONCRETE FLOOR SHALL BE TYPE "K" SOFT COPPER, CONTINUOUS. NO SPLICES OR FITTINGS WILL BE ALLOWED. 5. EXTREME CAUTION MUST BE TAKEN SO THAT NO COPPER PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB. 6. ALL PIPING UNDER CONCRETE FLOORS SHALL BE COVERED INSIDE A PVC PIPE G. PIPE SUPPORTS 1. PIPE SUPPORTS FOR HOT PIPE SHALL BE ANVIL FIG. 181 OR EQUAL. 2. PIPE SUPPORTS FOR NATURAL GAS SHALL BE ANVIL FIG. 260 OR EQUAL. PLUMBING SYSTEMS AND EQUIPMENT 0 ISO 114P A. GENERAL �`� e G ® AO' oOr 1. CONTRACTORS BIDDING THIS PROJECT SHALL VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THEIR WORK. SUBMISSION OF A BID ON THIS PROJECT SHALL BE CONSTRUED AS HAVING SUCH KNOWLEDGE. 2. VERIFY EXACT CONDITIONS IN FIELD AND COORDINATE WITH THESE DRAWINGS AND OTHER TRADES BEFORE BEGINNING NEW WORK. 3. DETERMINE EXACT LOCATIONS FOR ALL EQUIPMENT, PIPING, CONDUITS AND DUCTWORK IN FIELD. 4. COORDINATE WORK OF THIS CONTRACT WITH OTHER TRADES. CONFLICTS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE SITE ENGINEERS. SITE ENGINEERS RESOLUTION TO CONFLICTS SHALL BE FINAL. 5. ANY DISCREPANCIES BETWEEN WHAT IS SHOWN ON DRAWINGS OR SPECIFIED AND THE ACTUAL CONDITIONS IN THE FIELD SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE SITE ENGINEERS BEFORE PROCEEDING. 6. BUILDING AND SURFACES DAMAGED DURING INSTALLATION SHALL BE REPAIRED, REPLACED, AND/OR RESTORED TO ORIGINAL CONDITION AFTER COMPLETION OF WORK AND BEFORE ACCEPTANCE BY OWNER. B. EQUIPMENT It is a violation of the law for any person, unless acting under the direction of a licensed 1. PLUMBING CONTRACTOR TO FURNISH ALL PLUMBING EQUIPMENT INDICATED AND/OR SCHEDULED ON THE DRAWINGS Architect, Engineer or Land Surveyor, to alter an item in COMPLETE WITH BASES, ISOLATORS, SUPPORTS AND OTHER REQUIRED ACCESSORIES, any way. Plans, maps, 2. INSTALL COMPLETE AND PLACE IN PROPER OPERATION PER MANUFACTURER'S RECOMMENDATIONS, LUBRICATE AND reports�n�ottionscontainingea' eddink ADJUST AS REQUIRED. FURNISH AND INSTALL CLEAN SET OF FILTERS PRIOR TO BALANCING. seal imprint on the cover sheet accompanied by an original 3. EQUIPMENT TO BE MADE AND MODEL AS SCHEDULED UNLESS ALTERNATE EQUIPMENT OF EQUIVALENT QUALITY AND signature by the licensed professional may have been PERFORMANCE IS LIAS A SUBSTITUTIOPRIOR TO fraudulently ACCEPTANCE WITHOUT QUALIFICATION BY OWNER, ENGINEER AND BIDDING. tl S TE ENGINEERS. ARE SUBJECT TO copy. Copyright Protected 2018, not be considered an original Larson Design Group. PLUMBING INSTRUMENTS AND CONTROLS A. GENERAL 1. AFTER INSTALLATION, CHECK ALL EQUIPMENT AND PERFORM START UP IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 2. ALL PIPING SHALL BE TESTED AND FREE OF LEAKS AS REQUIRED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 3. WORK THAT IS SCHEDULED TO BE CONCEALED OR INSULATED SHALL REMAIN UNCOVERED UNTIL REQUIRED TESTS HAVE BEEN COMPLETED. IF THE CONSTRUCTION SCHEDULE REQUIRES, ARRANGE FOR TESTS ON SECTIONS OF THE SYSTEM AT A TIME. 4. BALANCE ALL SYSTEMS, CALIBRATE CONTROLS, CHECK FOR PROPER OPERATION AND SEQUENCE UNDER ALL CONDITIONS AND MAKE ALL NECESSARY ADJUSTMENTS. 5. INSTRUCT OWNER IN OPERATION OF SYSTEMS AND SUBMIT OPERATING AND MAINTENANCE MANUAL FOR ALL 0 EQUIPMENT AND SYSTEMS. V) 6. SUBMIT AIR AND WATER BALANCE REPORT FROM INDEPENDENT AABC OR NEBB CERTIFIED SUBCONTRACTOR FOR z w ALL AIR AND WATER SYSTEMS PER AABC OR NEBB STANDARDS.of 0 0 TESTING, ADJUSTING, AND BALANCING w A. BALANCING, START UP AND INSTRUCTIONS - a 1. AFTER EQUIPMENT IS PLACED IN OPERATION, SYSTEMS SHALL BE BALANCED WITH REPORT SUBMITTED TO OWNER. a. 2. START UP AND PLACE ALL SYSTEMS IN OPERATION AND TAG ALL SWITCHES AND CONTROLS WITH PERMANENT I - LABELS INSTRUCT OWNER ON PROPER OPERATION AND PREVENTATIVE MAINTENANCE OF SYSTEM. w J U 0 � F- o N a p 0 C.D c 0 a� c co J N J LL 0 0 cp U N O M o �LZ L 0 M o' r.,� �w°' 3cn OW s N W �0 J a > � WV C Jo • p 3 CL r~3 Ir O= O 3 J L ono • �n-�N C a) t° o V) 0 � Z E o 3 C 0 U) E z No cp n, �0==X J , 3,. it iai PROJECT NO. 11979-002 DRAWN BY EBG APPV'D BY RJG PLUMBING SPECIFICATIONS SHEET NO. P0.1 GENERAL NOTES: A. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ANY REMOVAL OR INSTALLATION. B. ALL PLUMBING LINES NOT BEING REUSED ARE TO BE REMOVED, CAPPED —OFF OR TERMINATED BELOW SLAP, ABOVE CEILING, OR WITHIN REMAINING WALLS. C. CONTRACTOR TO VERIFY EXACT TIE IN POINT AND INVERT. D. CAMERA LINES AS REQ'D TO VERIFY DIRECTION OF FLOW. VERIFY EXACT LOCATION IN FIELD. E. CONTRACTOR TO VERIFY EXISTING WATER RISER, BACKFLOW PREVENTER, DOUBLE CHECK VALVE, AND METER ARE EXISTING. VERIFY CODE AND WATER AUTHORITY COMPLIANCE. MODIFY EXISTING / INSTALL NEW IF / AS REQ'D. KEYED NOTES x0 1. REMOVE EXISTING LAVATORY AS SHOWN. PREPARE FIXTURE FOR RELOCATION. REF: P1.0. 2. SAWCUT / TRENCH AS REQ'D TO CONNECT NEW SANITARY LINE BACK TO EXISTING. G.C. TO VERIFY EXACT LOCATION IN FIELD. REF: 2/D1.0 FOR POUR BACK DETAIL. 3. EXISTING MOP SINK AND WATER HEATER ABOVE TO REMAIN. 4. EXSTING PIPE TO REMAIN. 5. EXISTING WATER CLOSET TO REMAIN. CLEAN AS REQUIRED. DEMOLITION PLAN(A)PLUMBING SCALE: 1 /4"=V-0" of P4c O 0092168 V = 0 /201 El It is a violation of the law for any person, unless acting under the direction of a licensed Architect. Engineer or Land Surveyor, to alter an item in any way. Plans, mops, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. z O U) �5 w w 0 0 U W Z) En fn Ld H Q EL H- Z W J U 00 O LU \ I -- O Q CN n O O .- Z CL 0 O rL^ V 0 L c _J AT 1 ` N 1 (h J L z ro E Oo (p U L N 0 Q) l� 0 c Y Z Q% O L W Cl) 'a' 3 U OW J fn L LU LL r°n W0 ac ao 03 ir �3 pro 3 J >L . M ■ a_N ��(0 c Qco� in r j Z C O V In O OO E2O0Z� CU O - _ Jo a r PROJECT NO. 11979-002 DRAWN BY EB G APPYD BY RJG PLUMBING DEMOLITION PLAN SHEET NO. PD1.a OF E4 0� 5 9t� ~ 188 0 i 2 1 20 201 _ Ln 1\ y WH 2 > O 2"V P4 6 L----� 5 > 3 �I P3 2 3'V ( N I > IN RESTROOM STOCKROOM - - - - 4,. 3 �- i P2 -, P4 106 102 0 `� 2" 4„ ,. 3 2" it is a violation of the low for i any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an Item in 4" any way. Plans. maps, specifications, studies, and reports not containing a red Ink SANITARY PIPING RISER seal imprint on the laver sheet accompanied by an original signature by the licensed Z Q professional may have been SCALE: fraudulently altered and shall l� not be considered an original copy. Copyright Protected 2018, P1 1 Larson Design Group. " SALES RESTROOM 101 107 G� 2 2 4 � 4 00, / =I /I I _ , 04 i� i PIPING PLAN 1 \ ( U)o ALE: 3 8 =1 —0 I I- > �SC ANITARY / W �,, � I \ O \ i \ o w N ( (n U) LLI I i- - — — — Z LLJ U a y� �I \ v \ o a P3 EWH N N o o P1 Z CL RESTROOM STOCKROOM F I� c 1 \ P 0 c 0 DOMESTIC WATER RISER OE:)1 P1 4 SCALE: 3/8" =1'—O" 1—� n cl SALES J to E U. � 00 101 L (0 Q co 0: �'0 ( a Y Q W a) Co W ® 1 P2 OW c. W 0 J LL ai . > W a > O 3 0 °- o 3 / � pro 3 W 2 o0, o . LEGEND C N DOMESTIC WATER PIPING PLAN � W a i 2 SCALE: 3/8"-1'-0" SANITARY SEWER W Q M to Z 0 � o r ��i, - DOMESTIC COLD WATER O 5 LO o 0 00EWLi z DOMESTIC HOT WATER o o KEYED NOTES ❑x GENERAL NOTES - - 0 J o a 1. INSTALL NEW PLUMBING FIXTURE IN LOCATION A. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR - - - - - - PLUMBING VENT r SHOWN. VERIFY SIZE AND POINT OF CONNECTION IN TO ANY INSTALLATION. FIELD. B. THE PLUMBING SYSTEM (SANITARY, WASTE �I�— UNION 2. EXISTING MOP SINK AND WATER HEATER ABOVE TO DISTRIBUTION) AND ALL ASSOCIATED EQUIPMENT WILL REMAIN. FIXTURE SHALL BE CLEANED AS REQUIRED BE INSTALLED AND MAINTAINED IN ACCORDANCE TO LIKE NEW CONDITION. SHOULD ANY FIXTURES WITH THE FULL REQUIREMENTS OF THE PLUMBING G ELBOW - TURNED DOWN REQUIRE REPLACEMENT, CONTRACTOR SHALL CODE. IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE AND C. DO NOT RUN PIPING ABOVE ELECTRICAL PANELS OR o ELBOW - TURNED UP SUBMIT A WRITTEN COST PROPOSAL TO REPLACE IN CODE REQUIRED CLEARANCE SPACES. COORDINATE INCLUDING A TIME ESTIMATE TO COMPLETE REPAIRS. ALL ROUTES WITH ALL TRADES PRIOR TO TEE - TURNED DOWN CONTRACTOR SHALL ALSO ROD DRAINS TO INSURE INSTALLATION. PROPER FLOW. D. CONTRACTOR TO VERIFY EXACT TIE IN POINT AND 3• CONNECT NEW 4" SANITARY LINE TO EXISTING MIN. INVERT IN FIELD. o TEE -TURNED UP 4" SANITARY LINE. VERIFY SIZE AND POINT OF E. VENTS THROUGH ROOF SHALL NOT BE LOCATED CONNECTION IN FIELD. WITHIN 10'-0" OF OUTSIDE AIR SUPPLIES. VENTS GATE VALVE 4• CONNECT NEW 1/2" WATER TO EXISTING 1/2" MIN. SHALL BE LOCATED NO CLOSER THAN 5'-0" TO ANY �� COLD WATER AND HOT WATER LINE. VERIFY SIZE PARAPET. BALL VALVE AND POINT OF CONNECTION IN FIELD. F. MINIMUM U/G WASTE PIPING SHALL BE Y. 5 CONNECT BACK TO NEAREST EXISTING SANITARY G. CONTRACTOR TO VERIFY EXISTING WATER RISER, CHECK VALVE PROJECT NO. 11979-002 VENT LINE. VERIFY EXACT LOCATION IN FIELD. BACKFLOW PREVENTER, DOUBLE CHECK VALVE, AND METER ARE EXISTNG. VERIFY CODE AND WATER �>cSHUT-OFF VALVE DRAWN BY EBG 6. EXISTING LAVATORY TO BE RELOCATED. FIXTURE AUTHORITY COMPLIANCE. MODIFY EXISTING / INSTALL IN VERTICAL LINE SHALL BE CLEANED AS REQUIRED TO "LIKE NEW" NEW IF / AS REQ'D. APPN'D BY RJG CONDITION. SHOULD ANY FIXTURES REQUIRE T WCO WALL CLEANOUT REPLACEMENT, CONTRACTOR SHALL IMMEDIATELY H. CAMERA LINES AS REQ'D TO VERIFY DIRECTION OF NOTIFY OWNER'S REPRESENTATIVE AND SUBMIT A FLOW. VERIFY EXACT LOCATION IN FIELD. -O 0 DOUBLE CLEANOUT PLUMBING PLAN & WRITTEN COST PROPOSAL TO REPLACE INCLUDING A DETAILS SHEET NO. TIME ESTIMATE TO COMPLETE REPAIRS. CONTRACTOR ® EXISTING METER SHALL ALSO ROD DRAINS TO INSURE PROPER FLOW. 1 NPLAN ORTH P1O PLUMBING FIXTURE SCHEDULE CONNECTIONS MARK DESCRIPTION MANUFACTURER MODEL # NOTES WASTE VENT COLD HOT FURNISH ADA CLOSET &TANK, ADA OPEN FRONT SEAT, FLOOR FLANGE, CLOSET BOLTS &CAPS, WAX P1 WATER CLOSET ZURN Z5560 4" 2" 1/2" - RING, SUPPLY STOP &TUBE. FLUSH CONTROL MUST BE LOCATED ON THE WIDE SIDE OF THE WC (SIDE OPPOSITE THE WALL) Z5340 METERING FURNISHED WITH LAVATORY, ZURN Z86660 GOOSE. P2 LAVATORY ZURN FAUCET ON 4" 2" 1-1/2" 1/2" 1/2" NECK FAUCET, SELF CLOSING/METERING WALL CENTERS HANGER KIT, SUPPLY STOP AND TUBES, DRINK KIT & TAILPIECE. P3 EXISTING MOP -- BASIN P4 RELOCATED - LAVATORY � EXISTING WATER HEATER EXISTING WORK A. PRIOR TO CONSTRUCTION & INSTALLATION, CONTRACTOR TO VERIFY EXISTING CONDITIONS AND NOTIFY ARCHITECT/ENGINEER OF CONFLICTS OR CONDITIONS WHICH INTERFERE WITH INSTALLATION AS SET FORTH IN CONTRACT DOCUMENTS. B. CONTRACTOR RESPONSIBLE FOR ALL NEW FLOOR OPENINGS, EXCAVATIONS, AND PENETRATIONS,UNLESS SPECIFICALLY NOTED. UNLESS SPECIFICALLY NOTED, UPON COMPLETION, ALL PENETRATIONS TO BE SEALED TO MAINTAIN FIRE RATING AS SPECIFIED ON ARCHITECTURAL DRAWINGS. C. ALL CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS CLEARLY INDICATED AS PART OF ANOTHER PRIME CONTRACT. D. COORDINATE ANY NEW ROOF PENETRATIONS WITH THE OTHER TRADES. E. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. F. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. G. MAINTAIN ACCESS TO EXISTING BOXES AND OTHER INSTALLATIONS REMAINING ACTIVE AND REQUIRING ACCESS. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL. H. EXTEND EXISTING RACEWAY AND BOX INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. 1. CLEAN AND REPAIR EXISTING COMPONENTS TO REMAIN OR TO BE REINSTALLED. J. PROVIDE ACCESS TO EXISTING WIRING CONNECTIONS REMAINING ACTIVE AND REQUIRING ACCESS. MODIFY INSTALLATION OR INSTALL ACCESS PANEL. K. EXTEND EXISTING CIRCUITS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. L. RING OUT CIRCUITS IN EXISTING PANEL AFFECTED BY THE WORK. WHERE ADDITIONAL CIRCUITS ARE NEEDED, REUSE CIRCUITS AVAILABLE FOR REUSE. INSTALL NEW BREAKERS. M. TAG UNUSED CIRCUITS AS SPARE AND SWITCH BREAKER TO THE "OFF" POSITION. N. WHERE EXISTING CIRCUITS ARE INDICATED TO BE REUSED, USE SENSING MEASURING DEVICES TO VERIFY CIRCUITS FEEDING PROJECT AREA OR ARE NOT IN USE. 0. PROVIDE NEW UPDATED DIRECTORIES WHERE MORE THAN THREE CIRCUITS HAVE BEEN MODIFIED OR REWIRED. P. IDENTIFY SALVAGE ITEMS IN COOPERATION WITH OWNER. REMOVE AND PROTECT ITEMS TO BE SALVAGED AND TURN OVER TO OWNER. Q. CAREFULLY REMOVE EQUIPMENT, MATERIALS, OR FIXTURES WHICH ARE TO BE REUSED. MINOR ELECTRICAL DEMOLITION A. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND EXISTING RECORD DOCUMENTS. REPORT DISCREPANCIES TO ARCHITECT/ENGINEER BEFORE DISTURBING EXISTING INSTALLATION. B. CEASE OPERATIONS IMMEDIATELY WHEN STRUCTURE APPEARS TO BE IN DANGER AND NOTIFY ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED. C. VERIFY WIRING AND EQUIPMENT INDICATED TO BE DEMOLISHED SERVE ONLY ABANDONED FACILITIES. D. PROVIDE TEMPORARY EGRESS SIGNAGE AND EMERGENCY LIGHTING. E. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. REMOVE CONDUIT, WIRE, BOXES, AND FASTENING DEVICES TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. F. INSTALL TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. G. REMOVE EXPOSED ABANDONED WIRE, CABLE, CONDUIT, GROUNDING AND BONDING COMPONENTS, FASTENERS AND SUPPORTS, AND ELECTRICAL IDENTIFICATION COMPONENTS, INCLUDING ABANDONED COMPONENTS ABOVE ACCESSIBLE CEILING FINISHES. CUT EMBEDDED CONDUITS AND SUPPORT ELEMENTS FLUSH WITH WALLS AND FLOORS. PATCH SURFACES DAMAGED BY REMOVAL OF EXISTING COMPONENTS. H. DISCONNECT ABANDONED CIRCUITS AND OUTLETS AND REMOVE ABANDONED RACEWAY, OUTLETS, BOXES, WIRE, AND CABLE INCLUDING ABOVE ACCESSIBLE CEILING FINISHES. CUT RACEWAY FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES. REMOVE CONCEALED ABANDONED RACEWAY TO ITS SOURCE. I. RECONNECT EQUIPMENT BEING DISTURBED BY RENOVATION WORK AND REQUIRED FOR CONTINUED SERVICE TO NEAREST AVAILABLE PANEL. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. J. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. K. CLEAN AND REPAIR EXISTING EQUIPMENT TO REMAIN (AFFECTED BY THE SCOPE OF THE PROJECT) OR TO BE REINSTALLED. L. PROTECT AND RETAIN POWER TO EXISTING ACTIVE EQUIPMENT REMAINING. M. CAP ABANDONED EMPTY CONDUIT AT BOTH ENDS AND MARK AS SPARE. RACEWAY AND BOXES A. PROVIDE RACEWAY AND BOXES LOCATED AS INDICATED, AND AT OTHER LOCATIONS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, AND COMPLIANCE WITH REGULATORY REQUIREMENTS. RACEWAY AND BOXES ARE SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. PROVIDE RACEWAY TO COMPLETE WIRING SYSTEM. B. UNDERGROUND MORE THAN 5 FEET OUTSIDE FOUNDATION WALL: PROVIDE SCHEDULE 80 PVC. PROVIDE CAST METAL BOXES OR NONMETALLIC HANDHOLES WHERE REQUIRED. C. UNDERGROUND WITHIN 5 FEET FROM FOUNDATION WALL: PROVIDE RIGID STEEL CONDUIT OR THICKWALL NONMETALLIC CONDUIT (SCHEDULE 80 PVC). PROVIDE CAST METAL OR NONMETALLIC BOXES. D. IN OR UNDER SLAB ON GRADE: PROVIDE THICK WALL NONMETALLIC CONDUIT. PROVIDE CAST OR NONMETALLIC METAL BOXES. E. OUTDOOR LOCATIONS, ABOVE GRADE: PROVIDE RIGID STEEL CONDUIT. PROVIDE CAST METAL OR NONMETALLIC OUTLET, PULL, AND NEMA-3R RATED JUNCTION BOXES. F. IN SLAB ABOVE GRADE: PROVIDE THICKWALL NONMETALLIC CONDUIT. PROVIDE CAST NONMETALLIC BOXES. G. WET AND DAMP LOCATIONS: PROVIDE THICKWALL NONMETALLIC CONDUIT. PROVIDE CAST METAL OR NONMETALLIC OUTLET, NEMA-3R RATED JUNCTION, AND PULL BOXES. PROVIDE FLUSIMOUNTING OUTLET BOX IN FINISHED AREAS. H. CONCEALED DRY LOCATIONS: PROVIDE ELECTRICAL METALLIC TUBING. PROVIDE SHEET -METAL BOXES. PROVIDE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. PROVIDE HINGED ENCLOSURE FOR LARGE PULL BOXES. 1. MINIMUM RACEWAY SIZE: 3/4 INCH UNLESS OTHERWISE SPECIFIED. J. ARRANGE RACEWAY AND BOXES TO MAINTAIN HEADROOM AND PRESENT NEAT APPEARANCE. GROUP RELATED RACEWAY, SUPPORT USING CONDUIT RACK; PROVIDE SPACE ON EACH FOR 25 PERCENT ADDITIONAL RACEWAYS. K. RACEWAY ROUTING IS SHOWN IN APPROXIMATE LOCATIONS UNLESS DIMENSIONED. ROUTE TO COMPLETE WIRING SYSTEM. L. DO NOT SUPPORT RACEWAY WITH WIRE, PERFORATED PIPE STRAPS, CEILING SUPPORT WIRES OR OTHER PIPING SYSTEMS. M. ROUTE EXPOSED & ABOVE ACCESSIBLE CEILINGS RACEWAY PARALLEL AND PERPENDICULAR TO WALLS. N. DO NOT CROSS CONDUITS IN SLAB. 0. INSTALL NO MORE THAN EQUIVALENT OF THREE 90 DEGREE BENDS BETWEEN BOXES. INSTALL CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS. INSTALL FACTORY ELBOWS FOR BENDS IN METAL CONDUIT LARGER THAN 2 INCH SIZE. P. AVOID MOISTURE TRAPS; INSTALL JUNCTION BOX WITH DRAIN FITTING AT LOW POINTS INCONDUIT SYSTEM. Q. INSTALL FITTINGS TO ACCOMMODATE EXPANSION AND DEFLECTION WHERE RACEWAY CROSSES SEISMIC, CONTROL AND EXPANSION JOINTS. R. INSTALL SUITABLE PULL STRING OR CORD IN EACH EMPTY RACEWAY EXCEPT SLEEVES AND NIPPLES. S. CLOSE ENDS AND UNUSED OPENINGS IN WIREWAY. T. INSTALL PULL BOXES AND JUNCTION BOXES ABOVE ACCESSIBLE CEILINGS AND IN UNFINISHED AREAS ONLY. U. IN ACCESSIBLE CEILING AREAS: INSTALL OUTLET AND JUNCTION BOXES NO MORE THAN 6 INCHES FROM CEILING ACCESS PANEL OR FROM REMOVABLE RECESSED LUMINAIRE. V. LOCATE FLUSH MOUNTING BOX IN MASONRY WALL TO REQUIRE CUTTING OF MASONRY UNIT CORNER ONLY. COORDINATE MASONRY CUTTING TO ACHIEVE NEAT OPENING. W. DO NOT INSTALL FLUSH MOUNTING BOX BACK-TO-BACK IN WALLS; INSTALL WITH MINIMUM 6 INCHES SEPARATION. INSTALL WITH MINIMUM 24 INCHES SEPARATION IN ACOUSTIC RATED WALLS. X. DO NOT FASTEN BOXES TO CEILING SUPPORT WIRES OR OTHER PIPING SYSTEMS. Y. SUPPORT BOXES INDEPENDENTLY OF CONDUIT. Z. USE FLUSH MOUNTING OUTLET BOX IN FINISHED AREAS. AA. SET FLOOR BOXES LEVEL AND FLUSH WITH FINISH FLOORING MATERIAL AB. INSTALL CONDUIT TO PRESERVE FIRE RESISTANCE RATING OF PARTITIONS AND OTHER ELEMENTS. AC. ROUTE CONDUIT THROUGH ROOF OPENINGS FOR PIPING AND DUCTWORK OR THROUGH SUITABLE ROOF JACK WITH PITCH POCKET AD. ALIGN ADJACENT WALL MOUNTED OUTLET BOXES FOR SWITCHES, THERMOSTATS, AND SIMILAR DEVICES. ELECTRICAL SPECIFICATIONS A. ALL ELECTRICAL WORK TO CONFORM TO: 1. NFPA 70 (NATIONAL ELECTRIC CODE) - CURRENT VERSION 2. NECA (NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION) - STANDARD OF INSTALLATION 3. NETA ATS (INTERNATIONAL ELECTRICAL TESTING ASSOCIATION) - ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER DISTRIBUTION EQUIPMENT AND SYSTEMS. 4. NFPA 72 (NATIONAL FIRE PROTECTION ASSOCIATION - NATIONAL FIRE ALARM CODE). 5. ALL APPLICABLE LOCAL CODES. B. ALL WORK SHOWN ON THIS DRAWING IS THE RESPONSIBILITY OF THE CONTRACTOR, UNLBaffARLY INDICATED AS PART OF ANOTHER PRIME CONTRACT. C. PROVIDE TEMPORARY POWER REQUIRED FOR ALL TRADES. D. MATCH OWNERS EXISTING STANDARD EQUIPMENT. E. COORDINATE WORK TO MINIMIZE OUTAGE DURATION. F. OBTAIN ALL REQUIRED PERMITS & INSPECTIONS. G. PROVIDE FOR ELECTRICAL INSPECTIONS AND SUBMIT REPORTS TO THE OWNER. H. SUBMIT 0&M MANUALS TO OWNER UPON COMPLETION OF WORK. I. PROVIDE TRAINING SESSION FOR DESIGNATED MAINTENEANCE PERSONNEL. J. PROVIDE SUBMITTALS FOR ALL ELECTRICAL EQUIPMENT, EXCLUDING WIRE, CONDUIT, AND FASTENERS. 1. HANDHOLES. 2. PANELBOARDS - SHOP DRAWINGS (INDICATE OUTLINE AND SUPPORT POINT DIMENSIONS, VOLTAGE, MAIN BUS AMPACITY, INTEGRATED SHORT CIRCUIT AMPERE RATING, CIRCUIT BREAKER AND FUSIBLE SWITCH ARRANGEMENT AND SIZES) AND CATALOG DATA SHOWING SPECIFIED FEATURES OF STANDARD PRODUCTS. 3. ENCLOSED SWITCHES - SWITCH RATINGS AND ENCLOSURE DIMENSIONS. 4. DEVICES - MANUFACTURER'S CATALOG INFORMATION SHOWING DIMENSIONS, COLORS, AND CONFIGURATIONS. 5. LUMINAIRES (INCLUDING EMERGENCY & EXIT FIXTURES) - CATALOG INFORMATION SHOWING DIMENSIONS, RATINGS, AND PERFORMANCE DATA. K. SELECT MATERIALS, SIZES, AND TYPES OF ANCHORS, FASTENERS, AND SUPPORTS TO CARRILOADS OF EQUIPMENT AND RACEWAY, INCLUDING WEIGHT OF WIRE AND CABLE IN RACEWAY. GROUNDING SYSTEMS A. GROUNDING SYSTEM RESISTANCE: 25 OHMS. B. GROUNDING SYSTEMS: 1. MECHANICAL CONNECTORS: BRONZE CONNECTORS, SUITABLE FOR GROUNDING AND BONDING APPLICATIONS, IN CONFIGURATIONS REQUIRED FOR PARTICULAR INSTALLATION. C. EXOTHERMIC CONNECTIONS: EXOTHERMIC MATERIALS, ACCESSORIES, AND TOOLS FOR PREPARING AND MAKING PERMANENT FIELD CONNECTIONS BETWEEN GROUNDING SYSTEM COMPONENTS. D. WIRE: STRANDED COPPER. E. GROUNDING ELECTRODE CONDUCTOR: SIZE TO MEET NFPA 70 AND LOCAL MUNICIPALITY REQUIREMENTS. F. INSTALLATION: 1. EQUIPMENT GROUNDING CONDUCTOR: INSTALL SEPARATE, INSULATED CONDUCTOR WITHIN EACH FEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG, BUS, OR BUSHING. 2. DO NOT FASTEN SUPPORTS TO PIPES, DUCTS, MECHANICAL EQUIPMENT, OR CONDUIT. 3. OBTAIN PERMISSION FROM ARCHITECT/ENGINEER BEFORE USING POWDER -ACTUATED ANCHORS OR DRILLING OR CUTTING STRUCTURAL MEMBERS. HANGERS AND SUPPORTS A. ANCHORS & FASTENERS TO BE CORROSION RESISTANT. B. ANCHOR AND FASTEN ELECTRICAL PRODUCTS TO BUILDING ELEMENTS AND FINISHES AS FOLLOWS: 1. CONCRETE STRUCTURAL ELEMENTS: PROVIDE EXPANSION ANCHORS. 2. STEEL STRUCTURAL ELEMENTS: PROVIDE BEAM CLAMPS AND SPRING STEEL CLIPS. 3. CONCRETE SURFACES: PROVIDE EXPANSION ANCHORS. 4. HOLLOW MASONRY, PLASTER, AND GYPSUM BOARD PARTITIONS: PROVIDE TOGGLE BOLTS AND HOLLOW WALL FASTENERS. 5. SOLID MASONRY WALLS: PROVIDE EXPANSION ANCHORS. 6. SHEET METAL: PROVIDE SHEET METAL SCREWS. 7. WOOD ELEMENTS: PROVIDE WOOD SCREWS. C. SUPPORTS: 1. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR FORMED STEEL MEMBERS. RIGIDLY WELD MEMBERS OR INSTALL HEXAGON HEAD BOLTS TO PRESENT NEAT APPEARANCE WITH ADEQUATE STRENGTH AND RIGIDITY. INSTALL SPRING LOCK WASHERS UNDER NUTS. 2. INSTALL SURFACE MOUNTED CABINETS AND PANELBOARDS WITH MINIMUM OF FOUR ANCHORS. 3. IN WET AND DAMP LOCATIONS INSTALL STEEL CHANNEL SUPPORTS TO STAND CABINETS AND PANELBOARDS 1 INCH OFF WALL. 4. INSTALL SHEET METAL CHANNEL TO BRIDGE STUDS ABOVE AND BELOW CABINETS AND PANELBOARDS RECESSED IN HOLLOW PARTITIONS. BUILDING WIRE AND CABLE A. PROVIDE PRODUCTS AS FOLLOWS: 1. SOLID CONDUCTOR FOR FEEDERS AND BRANCH CIRCUITS 10 AWG AND SMALLER. 2. STRANDED CONDUCTORS FOR CONTROL CIRCUITS. 3. CONDUCTOR NOT SMALLER THAN #12 AWG FOR POWER AND LIGHTING CIRCUITS. 4. CONDUCTOR NOT SMALLER THAN #16 AWG FOR CONTROL CIRCUITS. 5. 10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS LONGER THAN 75 FEET. 6. 10 AWG CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS LONGER THAN 200 FEET. B. WIRING METHODS: PROVIDE THE FOLLOWING WIRING METHODS: 1. CONCEALED DRY INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 2. ABOVE ACCESSIBLE CEILINGS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 3. WET OR DAMP INTERIOR LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. 4. UNDERGROUND LOCATIONS: USE ONLY BUILDING WIRE, TYPE THHN/THWN INSULATION, IN RACEWAY. C. WIRE AND CABLE ROUTING INDICATED IS APPROXIMATE UNLESS DIMENSIONED. INCLUDE WIRE AND CABLE LENGTHS WITHIN 10 FT OF LENGTH SHOWN. D. COMPLETELY AND THOROUGHLY SWAB RACEWAY BEFORE INSTALLING WIRE. E. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. F. SPECIAL TECHNIQUES --BUILDING WIRE IN RACEWAY: 1. PULL CONDUCTORS INTO RACEWAY AT SAME TIME. 2. INSTALL BUILDING WIRE 4 AWG AND LARGER WITH PULLING EQUIPMENT. G. SPECIAL TECHNIQUES - CABLE: 1. PROTECT EXPOSED CABLE FROM DAMAGE. 2. SUPPORT CABLES ABOVE ACCESSIBLE CEILING, USING SPRING METAL CLIPS OR CABLE TIES TO SUPPORT CABLES FROM STRUCTURE OR CEILING SUSPENSION SYSTEM. DO NOT REST CABLE ON CEILING PANELS. 3. USE SUITABLE CABLE FITTINGS AND CONNECTORS. H. SPECIAL TECHNIQUES - DIRECT BURIAL CABLE: 1. TRENCH AND BACKFILL FOR DIRECT BURIAL CABLE INSTALLATION. INSTALL WARNING TAPE ALONG ENTIRE LENGTH OF DIRECT BURIAL CABLE, WITHIN 3 INCHES OF GRADE. 2. USE SUITABLE DIRECT BURIAL CABLE FITTINGS AND CONNECTORS. 1. SPECIAL TECHNIQUES - WIRING CONNECTIONS: 1. CLEAN CONDUCTOR SURFACES BEFORE INSTALLING LUGS AND CONNECTORS. 2. MAKE SPLICES, TAPS, AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITH NO PERCEPTIBLE TEMPERATURE RISE. 3. TAPE UNINSULATED CONDUCTORS AND CONNECTORS WITH ELECTRICAL TAPE TO 150 PERCENT OF INSULATION RATING OF CONDUCTOR. 4. INSTALL SPLIT BOLT CONNECTORS OR MULTI -TAP BLOCKS FOR COPPER CONDUCTOR SPLICES AND TAPS, 6 AWG AND LARGER. 5. INSTALL SOLDERLESS PRESSURE CONNECTORS WITH INSULATING COVERS FOR COPPER CONDUCTOR SPLICES AND TAPS, 8 AWG AND SMALLER. 6. INSTALL INSULATED SPRING WIRE CONNECTORS WITH PLASTIC CAPS FOR COPPER CONDUCTOR SPLICES AND TAPS, 10 AWG AND SMALLER. 7. TERMINATE EXISTING ALUMINUM CONDUCTORS WITH TIN-PLATED, ALUMINUM -BODIED COMPRESSION CONNECTORS ONLY. FILL WITH ANTI -OXIDANT COMPOUND BEFORE INSTALLING CONDUCTOR. 8. INSTALL SUITABLE REDUCING CONNECTORS OR MECHANICAL CONNECTOR ADAPTORS FOR CONNECTING ALUMINUM CONDUCTORS TO COPPER CONDUCTORS. J. GROUND CONDUCTORS: 1. FOR 6 AWG AND SMALLER: GREEN. 2. FOR 4 AWG AND LARGER: IDENTIFY WITH GREEN TAPE AT BOTH ENDS AND VISIBLE POINTS INCLUDING JUNCTION BOXES. K. ALL WIRING SHALL BE #12 CU UNLESS SPECIFIED OTHERWISE. IDENTIFICATION A. IDENTIFY ELECTRICAL COMPONENTS AS FOLLOWS: 1. ENGRAVED LAMINATED PLASTIC NAMEPLATE FOR EACH ELECTRICAL DISTRIBUTION, CONTROL EQUIPMENT ENCLOSURE, AND COMMUNICATION CABINET. 2. CLOTH TYPE WIRE MARKER FOR EACH CONDUCTOR AT PANELBOARD GUTTERS, AND PULL BOXES. 3. RACEWAY MARKER FOR EACH RACEWAY WHERE IT STUBS ABOVE THE CEILING OR BELOW THE FLOOR. 4. UNDERGROUND WARNING TAPE ALONG LENGTH OF EACH UNDERGROUND RACEWAY OR CABLE, 3" BELOW FINISHED GRADE. TAPE TO BE 4-INCH WIDE PLASTIC TAPE, DETECTABLE TYPE, COLORED YELLOW WITH SUITABLE WARNING LEGEND DESCRIBING BURIED ELECTRICAL LINES. SEALING AND FIREPROOFING EMERGENCY LED LIGHTING A. INSTALL FIRESTOPPING TO MAINTAIN ALL RATINGS AT ALL FIRE SEPARATIONS. A. MANUFACTURERS: B. FIRE RATED SURFACE: 1. AS SPECIFIED BY LIGHT FIXTURE SCHEDULE. 1. SEAL OPENING AT AS FOLLOWS: B. PRODUCT DESCRIPTION: SELF-CONTAINED LED EMERGENCY LIGHTING UNIT, WITH SELF -TEST DIAGNOSTICS. C. INSTALL 12 GAGE STEEL SLEEVE THROUGH OPENING AND EXTENDING BEYOND MINIMUM OF 1 INCH ON C. BATTERY: 12 VOLT, NICKEL -CADMIUM TYPE, WITH 1.5 HOUR CAPACITY. EACH SIDE OF BUILDING ELEMENT. D. BATTERY CHARGER: DUAL -RATE TYPE, WITH SUFFICIENT CAPACITY TO RECHARGE DISCHARGED BATTERY TO FULL CHARGE WITHIN TWELVE HOURS. D. SIZE SLEEVE ALLOWING MINIMUM OF 1 INCH VOID BETWEEN SLEEVE AND BUILDING ELEMENT. E. HOUSING: WHITE PLASTIC. E. PACK VOID WITH BACKING MATERIAL. F. INDICATORS: LAMPS TO INDICATE AC ON AND RECHARGING, VOLTMETER TO INDICATE BATTERY VOLTAGE. F. SEAL ENDS OF SLEEVE WITH UL LISTED FIRE RESISTIVE SILICONE COMPOUND TO MEET FIRE RATING OF G. TEST SWITCH: TRANSFERS UNIT FROM EXTERNAL POWER SUPPLY TO INTEGRAL BATTERY SUPPLY. STRUCTURE PENETRATED. H. AIM AND ADJUST LAMP FIXTURES TO PROVIDE OPTIMAL COVERAGE. 1. WHERE CABLE TRAY, BUS, CABLE BUS, CONDUIT, WIREWAY, OR TROUGH PENETRATES FIRE RATED SURFACE, INSTALL FIRESTOPPING PRODUCT IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED EXIT SIGNS INSTRUCTIONS. A. MANUFACTURERS: G. NON -RATED SURFACES: 1. AS SPECIFIED IN LIGHT FIXTURE SCHEDULE. 1. SEAL OPENING THROUGH NON -FIRE RATED ROOF OPENING AS FOLLOWS: B. PRODUCT DESCRIPTION: EXIT SIGN FIXTURE, WITH SELF -TEST DIAGNOSTICS. H. INSTALL 12 GAGE STEEL SLEEVE THROUGH OPENING AND EXTENDING BEYOND MINIMUM OF 1 INCH ON C. FACE: STENCIL FACE WITH RED LETTERS. EACH SIDE OF BUILDING ELEMENT. D. DIRECTIONAL ARROWS: UNIVERSAL TYPE FOR FIELD ADJUSTMENT. I. SIZE SLEEVE ALLOWING MINIMUM OF 1 INCH VOID BETWEEN SLEEVE AND BUILDING ELEMENT. E. MOUNTING: AS INDICATED ON DRAWINGS OR UNIVERSAL, FOR FIELD SELECTION. J. INSTALL TYPE OF FIRESTOPPING MATERIAL RECOMMENDED BY MANUFACTURER. F. BATTERY: 12 VOLT, NICKEL -CADMIUM TYPE, WITH 1.5 HOUR CAPACITY. 1. EXTERIOR WALL OPENINGS BELOW GRADE: ASSEMBLE RUBBER LINKS OF MECHANICAL SEAL TO G. BATTERY CHARGER: DUAL -RATE TYPE, WITH SUFFICIENT CAPACITY TO RECHARGE DISCHARGED BATTERY TO FULL CHARGE WITHIN TWELVE HOURS. SIZE OF CONDUIT AND TIGHTEN IN PLACE, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. H. LAMPS: LED. I. INPUT VOLTAGE: 120 VOLTS. PANELBOARDS G. POSITION EXIT SIGN DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. A. MANUFACTURERS: 1. EATON/CUTLER-HAMMER. 2. GE ELECTRICAL. FI 3. SIEMENS/ITE. A 4. SQUARE D MODEL. B. BOLT -ON CIRCUIT BREAKER TYPE, DISTRIBUTION ,LIGHTING AND APPLIANCE BRANCH CIRCUIT PANELBOARD. B C. PANELBOARD BUS: COPPER CURRENT CARRYING COMPONENTS, RATINGS AS INDICATED ON DRAWINGS. FURNISH COPPER GROUND BUS IN EACH PANELBOARD; FURNISH INSULATED GROUND BUS AS INDICATED ON DRAWINGS. C D. MINIMUM INTEGRATED SHORT CIRCUIT RATING: 22,000 AMPERES RMS SYMMETRICAL FOR 240 VOLT PANELBOARDS; 65,000 AMPERES RMS SYMMETRICAL FOR 480 VOLT PANELBOARDS. E. MOLDED CASE CIRCUIT BREAKERS: NEMA AB 1, BOLT -ON TYPE THERMAL MAGNETIC TRIP CIRCUIT BREAKERS, D WITH COMMON TRIP HANDLE FOR ALL POLES, LISTED AS TYPE SWD FOR LIGHTING CIRCUITS, TYPE HACR FOR AIR CONDITIONING EQUIPMENT CIRCUITS, CLASS A GROUND FAULT INTERRUPTER CIRCUIT BREAKERS AS INDICATED ON DRAWINGS. DO NOT USE TANDEM CIRCUIT BREAKERS. E F. ENCLOSURE: NEMA PB 1, TYPE 1 G. CABINET BOX: 6 INCHES DEEP, 20 INCHES WIDE FOR 240 VOLT AND LESS PANELBOARDS, 20 INCHES WIDE FOR F. 480 VOLT PANELBOARDS. H. CABINET FRONT: SURFACE DOOR -IN -DOOR TYPE, FASTENED WITH HINGE AND LATCH, HINGED DOOR WITH FLUSH LOCK, METAL DIRECTORY FRAME, FINISHED IN MANUFACTURER'S STANDARD GRAY ENAMEL. OUTER PANELBOARD TRIMS SHALL COVER ALL LIVE PARTS. SWITCHING DEVICE HANDLES SHALL BE ACCESSIBLE. I. SURFACE TRIMS SHALL BE SAME HEIGHT AND WIDTH AS BOX. FLUSH TRIMS SHALL OVERLAP THE BOX BY 3/4 G OF AN INCH ON ALL SIDES. H J. INSTALL RECESSED PANELBOARDS FLUSH WITH WALL FINISHES. I. K. HEIGHT: 6 FEET TO TOP OF PANELBOARD; INSTALL PANELBOARDS TALLER THAN 6 FEET WITH BOTTOM NO J. MORE THAN 4 INCHES ABOVE FLOOR. L. INSTALL FILLER PLATES FOR UNUSED SPACES IN PANELBOARDS. M. PROVIDE TYPED CIRCUIT DIRECTORY FOR EACH BRANCH CIRCUIT PANELBOARD PER ARICHTECTURAL ROOM DESIGNATIONS. REVISE DIRECTORY TO REFLECT CIRCUITING CHANGES TO BALANCE PHASE LOADS. N. MARK UNUSED CIRCUIT BREAKERS AS SPARE AND SWITCH TO OFF POSITION. 0. MEASURE STEADY STATE LOAD CURRENTS AT EACH PANELBOARD FEEDER; REARRANGE CIRCUITS IN PANELBOARD TO BALANCE PHASE LOADS TO WITHIN 20 PERCENT OF EACH OTHER. MAINTAIN PROPER PHASING FOR MULTI -WIRE BRANCH CIRCUITS. ENCLOSED SWITCHES K A. MANUFACTURERS: L. 1. CUTLER -HAMMER. 2. SQUARE D. M 3. GE ELECTRICAL. N 4. SIEMENS. 0 B. PRODUCT DESCRIPTION: NEMA KS 1, TYPE HD WITH EXTERNALLY OPERABLE HANDLE INTERLOCKED TO PREVENT P OPENING FRONT COVER WITH SWITCH IN ON POSITION, ENCLOSED LOAD INTERRUPTER KNIFE SWITCH. HANDLE Q LOCKABLE IN OFF POSITION, WITH PROVISIONS FOR THREE PADLOCKS. C. SWITCH MECHANISM: TO BE QUICK -MAKE, QUICK -BREAK SUCH THAT, DURING NORMAL OPERATION OF THE SWITCH,R THE OPERATION OF THE CONTACTS SHALL NOT BE CAPABLE OF BEING RESTRAINED BY THE OPERATING HANDLE AFTER THE CLOSING OR OPENING ACTION OF THE CONTACTS HAS STARTED. D. FUSE CLIPS: DESIGNED TO ACCOMMODATE NEMA FU 1, CLASS R, J FUSES. S. E. ENCLOSURE: NEMA CONFIGURATION TO MEET CONDITIONS T. 1. INTERIOR DRY LOCATIONS: TYPE 1. 2. EXTERIOR LOCATIONS: TYPE 3R. 3. INDUSTRIAL LOCATIONS: TYPE 4X. F. SERVICE ENTRANCE: SWITCHES IDENTIFIED FOR USE AS SERVICE EQUIPMENT ARE TO BE LABELED FOR THIS APPLICATION. FURNISH SOLID NEUTRAL ASSEMBLY AND EQUIPMENT GROUND BAR. G. FURNISH SWITCHES WITH ENTIRELY COPPER CURRENT CARRYING PARTS. H. SWITCH RATING: HORSEPOWER RATED FOR AC AS INDICATED ON DRAWINGS. I. SHORT CIRCUIT CURRENT RATING: 200,000 RMS SYMMETRICAL AMPERES WHEN USED WITH OR PROTECTED BY CLASS R OR CLASS J FUSES (30-600 AMPERE SWITCHES EMPLOYING APPROPRIATE FUSE REJECTION SCHEMES). J. HEIGHT: 5 FEET TO OPERATING HANDLE. U. K. INSTALL FUSES FOR FUSIBLE DISCONNECT SWITCHES. WIRING DEVICES A. MANUFACTURERS: 1. PASS & SEYMOUR LEGRAND. 2. HUBELL. 3. LEVITON. 4. GENERAL ELECTRIC. B. PRODUCT DESCRIPTION: NEMA WD 1, HEAVY-DUTY, AC ONLY SPECIFICATION GRADE SWITCH/RECEPTACLE. ALL DEVICES TO BE SPECIFICATION GRADE OR BETTER. C. BODY / HANDLE: IVORY PLASTIC WITH TOGGLE HANDLE. D. RATINGS: MATCH BRANCH CIRCUIT AND LOAD CHARACTERISTICS, MINIMUM 20A. E. GFCI RECEPTACLE: CONVENIENCE RECEPTACLE WITH INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER TO MEET REGULATORY REQUIREMENTS. F. WP RECEPTACLE: (WEATHERPROOF) TO BE GFI PROTECTED. WALL PLATES A. MANUFACTURERS: 1. PASS & SEYMOUR LEGRAND. 2. TAYMAC 20510 (WEATHERPROOF -IN -USE). 3. HUBELL (BELL/RACO). 4. LEVITON. 5. GENERAL ELECTRIC. B. INSTALL DECORATIVE PLATES ON SWITCH, RECEPTACLE, AND BLANK OUTLETS IN FINISHED AREAS. DECORATIVE COVER PLATE: NYLON. C. INSTALL JUMBO SIZE PLATES FOR OUTLETS INSTALLED IN MASONRY WALLS. JUMBO COVER PLATE: NYLON. D. WEATHERPROOF COVER PLATE (RECEPTACLE): IMPACT RESISTANT PLASTIC PLATE WITH HINGED AND GASKETED DEVICE COVER. COVER TO BE RATED FOR WET LOCATION WHILE IN USE, AND TO BE LOCKABLE. E. WEATHERPROOF COVER PLATE (SWITCH): GASKETED CAST METAL PLATE WITH HINGED AND GASKETED DEVICE COVER OR LEVER SWITCH MECHANISM. (P&S CA-31G/HUBBELL/BELL/RACO 5125 OR EQUAL) F. KITCHEN AREAS: 302/430 STAINLESS STEEL, WEATHERPROOF FOR STARTUPS. G. INSTALL GALVANIZED (STAMPED) STEEL PLATES ON OUTLET BOXES AND JUNCTION BOXES IN UNFINISHED AREAS, ABOVE ACCESSIBLE CEILINGS, AND ON SURFACE MOUNTED OUTLETS. H. INSTALL DEVICES PLUMB AND LEVEL. I. INSTALL SWITCHES WITH OFF POSITION DOWN. J. INSTALL RECEPTACLES WITH GROUNDING POLE ON TOP, OR TO THE LEFT (IF MOUNTED HORIZONTALLY. K. CONNECT WIRING DEVICE GROUNDING TERMINAL TO OUTLET BOX WITH BONDING JUMPER AND BRANCH CIRCUIT EQUIPMENT GROUNDING CONDUCTOR. L. CONNECT WIRING DEVICES BY WRAPPING SOLID CONDUCTOR AROUND SCREW TERMINAL. INSTALL STRANDED CONDUCTOR FOR BRANCH CIRCUITS 10 AWG AND SMALLER. WHEN STRANDED CONDUCTORS ARE USED IN LIEU OF SOLID, USE CRIMP ON FORK TERMINALS FOR DEVICE TERMINATIONS. DO NOT PLACE BARE STRANDED CONDUCTORS DIRECTLY UNDER DEVICE SCREWS. M. ADJUST DEVICES AND WALL PLATES TO BE FLUSH AND LEVEL. INTERIOR LUMINAIRES A. ALL FIXTURES TO BE SPECIFICATION GRADE OR BETTER. B. PERFORMANCE REQUIREMENTS: FOR AREAS OF ASSEMBLY, SUBMIT POINT -BY -POINT LIGHT LEVEL CALCULATIONS TO VERIFY COMPLIANCE WITH DESIGN LEVELS. C. PROVIDE COMPLETE INTERIOR LUMINAIRE ASSEMBLIES, WITH FEATURES, OPTIONS, AND ACCESSORIES AS SCHEDULED. D. INSTALL SUSPENDED LUMINAIRES USING PENDANTS SUPPORTED FROM SWIVEL HANGERS. INSTALL PENDANT LENGTH REQUIRED TO SUSPEND LUMINAIRE AT INDICATED HEIGHT. E. SUPPORT LUMINAIRES LARGER THAN 2 X 4 FOOT SIZE INDEPENDENT OF CEILING FRAMING. F. INSTALL SURFACE MOUNTED LUMINAIRES PLUMB AND ADJUST TO ALIGN WITH BUILDING LINES AND WITH EACH OTHER. SECURE TO PREVENT MOVEMENT. G. EXPOSED GRID CEILINGS: SUPPORT SURFACE -MOUNTED LUMINAIRES ON GRID CEILING DIRECTLY FROM BUILDING. FASTEN SURFACE MOUNTED LUMINAIRES TO CEILING GRID MEMBERS USING BOLTS, SCREWS, RIVETS, OR SUITABLE CLIPS. H. INSTALL RECESSED LUMINAIRES TO PERMIT REMOVAL FROM BELOW. I. INSTALL RECESSED LUMINAIRES USING ACCESSORIES AND FIRESTOPPING MATERIALS TO MEET REGULATORY REQUIREMENTS FOR FIRE RATING. J. INSTALL CLIPS TO SECURE RECESSED GRID -SUPPORTED LUMINAIRES IN PLACE. K. CONNECT LUMINAIRES TO BRANCH CIRCUIT OUTLETS USING FLEXIBLE CONDUIT. MAXIMUM LENGTH FIXTURE WHIP TO BE 5 FEET. L. MAKE WIRING CONNECTIONS TO BRANCH CIRCUIT USING BUILDING WIRE WITH INSULATION SUITABLE FOR TEMPERATURE CONDITIONS WITHIN LUMINAIRE. M. AIM AND ADJUST LUMINAIRES TO PROVIDE LIGHT LEVELS CONSISTENT WITH DESIGN. RE ALARM SYSTEM SYSTEM DESCRIPTION: NONCODED ADDRESSABLE SYSTEM, WITH AUTOMATIC SENSITIVITY CONTROL OF CERTAIN SMOKE DETECTORS AND MULTIPLEXED SIGNAL TRANSMISSION, DEDICATED TO FIRE -ALARM SERVICE ONLY. SUBMITTALS 1. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. 2. SHOP DRAWINGS: FOR FIRE -ALARM SYSTEM. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. FIELD QUALITY -CONTROL REPORTS 1. OPERATION AND MAINTENANCE DATA: FOR FIRE -ALARM SYSTEMS AND COMPONENTS TO INCLUDE IN EMERGENCY, OPERATION, AND MAINTENANCE MANUALS. INSTALLER QUALIFICATIONS: 1. PERSONNEL SHALL BE TRAINED AND CERTIFIED BY MANUFACTURER FOR INSTALLATION OF UNITS. 2. INSTALLATION SHALL BE BY PERSONNEL CERTIFIED BY NICET AS FIRE -ALARM LEVEL II TECHNICIAN. OBTAIN FIRE -ALARM SYSTEM FROM SINGLE SOURCE FROM SINGLE MANUFACTURER. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. FIRE -ALARM SIGNAL INITIATION SHALL BE BY ONE OR MORE OF THE FOLLOWING DEVICES: 1. MANUAL STATIONS. 2. HEAT DETECTORS. 3. SMOKE DETECTORS. 4. AUTOMATIC SPRINKLER SYSTEM WATER FLOW. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. IDENTIFY ALARM AT FIRE -ALARM CONTROL UNIT AND REMOTE ANNUNCIATORS. TRANSMIT AN ALARM SIGNAL TO THE REMOTE ALARM RECEIVING STATION GENERAL REQUIREMENTS FOR FIRE -ALARM CONTROL UNIT: 1. FIELD -PROGRAMMABLE, MICROPROCESSOR -BASED, MODULAR, POWER -LIMITED DESIGN WITH ELECTRONIC MODULES, COMPLYING WITH UL 864 AND LISTED AND LABELED BY AN NRTL. 2. ADDRESSABLE CONTROL CIRCUITS FOR OPERATION OF MECHANICAL EQUIPMENT. 3. ALPHANUMERIC DISPLAY AND SYSTEM CONTROLS: ARRANGED FOR INTERFACE BETWEEN HUMAN OPERATOR AT FIRE -ALARM CONTROL UNIT AND ADDRESSABLE SYSTEM COMPONENTS INCLUDING ANNUNCIATION AND SUPERVISION. DISPLAY ALARM, SUPERVISORY, AND COMPONENT STATUS MESSAGES AND THE PROGRAMMING AND CONTROL MENU. 4. KEYPAD: ARRANGED TO PERMIT ENTRY AND EXECUTION OF PROGRAMMING, DISPLAY, AND CONTROL COMMANDS AND TO INDICATE CONTROL COMMANDS TO BE ENTERED INTO THE SYSTEM FOR CONTROL OF SMOKE -DETECTOR SENSITIVITY AND OTHER PARAMETERS. ADDRESSABLE INITIATION DEVICES THAT COMMUNICATE DEVICE IDENTITY AND STATUS. SMOKE SENSORS SHALL ADDITIONALLY COMMUNICATE SENSITIVITY SETTING AND ALLOW FOR ADJUSTMENT OF SENSITIVITY AT FIRE -ALARM CONTROL UNIT. TEMPERATURE SENSORS SHALL ADDITIONALLY TEST FOR AND COMMUNICATE THE SENSITIVITY RANGE OF THE DEVICE. ANNUNCIATOR AND DISPLAY: LIQUID -CRYSTAL TYPE, 1 LINE(S) OF 40 CHARACTERS, MINIMUM. INITIATING DEVICE, NOTIFICATION APPLIANCE, AND SIGNALING LINE CIRCUITS: NFPA 72, CLASS B. AUTOMATICALLY TRANSMIT ALARM, SUPERVISORY, AND TROUBLE SIGNALS TO A REMOTE ALARM STATION. GENERAL REQUIREMENTS FOR MANUAL FIRE -ALARM BOXES: COMPLY WITH UL 38. BOXES SHALL BE FINISHED IN RED WITH MOLDED, RAISED -LETTER OPERATING INSTRUCTIONS IN CONTRASTING COLOR; SHALL SHOW VISIBLE INDICATION OF OPERATION; AND SHALL BE MOUNTED ON RECESSED OUTLET BOX. IF INDICATED AS SURFACE MOUNTED, PROVIDE MANUFACTURER'S SURFACE BACK BOX. DOUBLE -ACTION MECHANISM REQUIRING TWO ACTIONS TO INITIATE AN ALARM, PULL -LEVER] TYPE; WITH INTEGRAL ADDRESSABLE MODULE ARRANGED TO COMMUNICATE MANUAL -STATION STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE -ALARM CONTROL UNIT. STATION RESET: KEY- OR WRENCH -OPERATED SWITCH. GENERAL REQUIREMENTS FOR SYSTEM SMOKE DETECTORS: 1. INTEGRAL ADDRESSABLE MODULE: ARRANGED TO COMMUNICATE DETECTOR STATUS (NORMAL, ALARM, OR TROUBLE) TO FIRE -ALARM CONTROL UNIT. 2. BASE MOUNTING: DETECTOR AND ASSOCIATED ELECTRONIC COMPONENTS SHALL BE MOUNTED IN A TWIST -LOCK MODULE THAT CONNECTS TO A FIXED BASE. PROVIDE TERMINALS IN THE FIXED BASE FOR CONNECTION TO BUILDING WIRING. 3. SELF -RESTORING: DETECTORS DO NOT REQUIRE RESETTING OR READJUSTMENT AFTER ACTUATION TO RESTORE THEM TO NORMAL OPERATION. 4. INTEGRAL VISUAL -INDICATING LIGHT: LED TYPE INDICATING DETECTOR HAS OPERATED AND POWER -ON STATUS 5. PHOTOELECTRIC SMOKE DETECTORS: 6. DETECTOR ADDRESS SHALL BE ACCESSIBLE FROM FIRE -ALARM CONTROL UNIT AND SHALL BE ABLE TO IDENTIFY THE DETECTOR'S LOCATION WITHIN THE SYSTEM AND ITS SENSITIVITY SETTING. AN OPERATOR AT FIRE -ALARM CONTROL UNIT, HAVING THE DESIGNATED ACCESS LEVEL, SHALL BE ABLE TO MANUALLY ACCESS THE FOLLOWING FOR EACH DETECTOR: 1. PRIMARY STATUS. 2. DEVICE TYPE. 3. PRESENT AVERAGE VALUE. 4. PRESENT SENSITIVITY SELECTED. 5. SENSOR RANGE (NORMAL, DIRTY, ETC.). HEAT DETECTORS, GENERAL REQUIREMENTS FOR HEAT DETECTORS: COMPLY WITH UL 521. REMOTE ANNUNCIATOR 1. ANNUNCIATOR FUNCTIONS SHALL MATCH THOSE OF FIRE -ALARM CONTROL UNIT FOR ALARM, SUPERVISORY, AND TROUBLE INDICATIONS. MANUAL SWITCHING FUNCTIONS SHALL MATCH THOSE OF FIRE -ALARM CONTROL UNIT, INCLUDING ACKNOWLEDGING, SILENCING, ESETTING, AND TESTING. 2. MOUNTING: FLUSH CABINET, NEMA 250, TYPE 1. 3. DISPLAY TYPE AND FUNCTIONAL PERFORMANCE: ALPHANUMERIC DISPLAY AND LED INDICATING LIGHTS SHALL MATCH THOSE OF FIRE - ALARM CONTROL UNIT. PROVIDE CONTROLS TO ACKNOWLEDGE, SILENCE, RESET, AND TEST FUNCTIONS FOR ALARM, SUPERVISORY, AND TROUBLE SIGNALS. EQUIPMENT INSTALLATION 1. COMPLY WITH NFPA 72 FOR INSTALLATION OF FIRE -ALARM EQUIPMENT. 2. INSTALL WALL -MOUNTED EQUIPMENT, WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES (1830 MM) ABOVE THE FINISHED FLOOR. LOCATE DETECTORS NOT CLOSER THAN 3 FEET (1 M) FROM AIR -SUPPLY DIFFUSER OR RETURN -AIR OPENING. LOCATE DETECTORS NOT CLOSER THAN 12 INCHES (300 MM) FROM ANY PART OF A LIGHTING FIXTURE. 4. FIRE -ALARM CONTROL UNIT: SURFACE MOUNTED, WITH TOPS OF CABINETS NOT MORE THAN 72 INCHES (1830 MM) ABOVE THE FINISHED FLOOR. 3. GROUND FIRE -ALARM CONTROL UNIT AND ASSOCIATED CIRCUITS; COMPLY WITH IEEE 1100. INSTALL A GROUND WIRE FROM MAIN SERVICE GROUND TO FIRE -ALARM CONTROL UNIT. 3. ENGAGE A FACTORY -AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN FIRE - ALARM SYSTEM. OF It is a violation of the law for any person, unless acting under the direction of a licensed Architect, Engineer or Land Surveyor, to alter an item in any way. Plans, maps, specifications, studies, and reports not containing a red ink seal imprint on the cover sheet accompanied by an original signature by the licensed professional may have been fraudulently altered and shall not be considered an original copy. Copyright Protected 2018, Larson Design Group. n 00 ►5 n 0 C� c rn c 0 E2 cc J n o M J B- 0 0 Cp U W 0 LL i ro 04 �LZ rn0 rn GN �c LM W 00 U N -t N W a� :3 w v V) W c HU J a LL c°n W V .2: 0 03 fr. Y O 3 JZ (o W U .- N a N E K� `o ZE r, PO 3 �°�'�� Lo E Z N o - _ rn T -j03a PROJECT NO. 11979-002 DRAWN BY EBG APPv'D BY RJG ELECTRICAL SPECIFICATIONS SHEET NO. EO. 1 1 f E r i S f