Loading...
HomeMy WebLinkAbout2100 Country Club Rd (a) 2 17-3046 Roof Specs and plansv k fit _ in SCIS Home = Log In User Registration Hot Topics Submit Surcharge Stats It Facts Publications FBC Staff BCIS Site Map Links Search R. i Product Approval USER: Public User Application Detail q t FL # FL16440-RlO Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative f Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Carlisle SynTec Systems 1285 Ritner Highway P.O. Box 7000 Carlisle, PA 17013 717)245-7000 malpezzi@syntec.carlisle.com Joe Malpezzi malpezzi@syntec.carlisle.com Robert Patton 1555 Ritner Highway Carlisle, PA 17013 717)245-7264 Robert.PATTON@syntec,cariisle.com Roofing Single Ply Roof Systems Evaluation Repo, L room a Florlda Reglstered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC O8/24/2018 John W. Knezevich, PE Validation Checklist - Hardcopy Received Standard Year TAS 110 2000 TAS 114 2011 TAS 131 1995 Sections from the Code r Product Approval Method Method 1 Option D v Date Submitted 01/30/2017 Date Validated 02/06/2017 Date Pending FBC Approval 02/08/2017 Date Approved 04/04/2017 Date Revised 08/30/2017 of FL i Model, Number or Name Description — — 16440.1 i Carlisle Sure -Weld TPO Single Ply Thermoplastic (TPO) single ply roof systems for HVHZ. Roof Systems Limits of Use Approved for use in HVHZ: Yes Installation Instructions A Approved for use outside HVHZ: No FL16440 R10 II 2017 al FTtd6 p c , are - Weld TPOImpactResistant: N/A HVHZ FL1644Q-R10 Ddf Design Pressure: +N/A/-495 Verified By: Robert Nleminen PE-59166 Other: 1.) The design pressure noted in this application Created by Independent Third Party: Yes Evaluation Reports pertains to one assembly. Refer to ER Appendix for all assemblies and max. design pressures. 2.) Refer to ER Section FL16440 pM , Fr ri . - .. 5 for Limitations. 3.) This Product Approval is for HVHZ TPO HVHZ' FL16440-RI0.Ddf jurisdictions. Refer to FL24083 for Non-HVHZ. Created by Independent Third Party: Yes I s Contact U :: 2601 Blair Stone Road Tallahassee FL 3 399 Phone: 8 0-487-16 4 The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida :: PflyacY Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pubic -records request, do not send electronicmailtothisentity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section45S.275(Q, Florida Statutes, effective October 1, 2012, licensees: licensed under Chapter 455, F.S. must provide the Department with an email address if they haveone. The emaiis provided may be used for official communication with the. licensee. However email addresses are public record. If you do not wish to supply a personaladdress, please provide the Department with an email address which can be made aval fable to the public: To determine it you are a licensee under Chapter 455, F.S., Please click hen . Product Approval Accepts: Sao¢ Credit Card Safe r n_terdtek a. ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: E5450.02-801-44 Rendered to: Diamond Door Products Hempstead, Texas PRODUCT TYPE: Steel Outswing Door SERIES/MODEL: 4080 130mph Wind Rated Door ENO No. 72012 ' w `W= STATE OF :?\ 011111110 k DO.M SOW by: TyW W.,r w*V 2015.07.03 12:02:01-07'00' Test Date(s): 03/13/15 Through: 03/15/15 Report Date: 05/31/15 Revision 2: 07/02/15 Record Retention End Date: 03/15/19 1 2865 Market Loop Southlake, TX 76092 www.archtest.com . www.intertek.com/building p• 817.410.7202 f. 717.764.4129 I Ott s sf,,' i Architectural Testing 1.0 Report Issued To: 2.0 Test Laboratory: 3.0 Project Summary: . Diamond Door Products 52294 Hwy 290 West Hempstead, Texas 77445 Architectural Testing, Inc. 2865 Market Loop Southlake, Texas 76092 817) 410- 7202 Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 2: 07/02/15 Page 2 of 12 3.1 Product Type: Steel Outswing Door 3.2 Series/Model: 4080 130mph Wind Rated Door 3.3 Compliance Statement: Results obtained are tested values and were secured by using the designated test method(s). The specimen(s) tested met the performance requirements set forth in the referenced test procedures for a +1035 Pa (+40.76 psf), and -871 Pa (-34.30 psf) Design Pressure with missile impacts corresponding to Missile Level D and Wind Zone 3. 3.4 Test Date(s): 03/13/15- 03/15/15 3.5 Test Record Retention End Date: All test records for this report will be retained until March 15, 2019 3.6 Test Location: Architectural Testing, Inc. test facility in Southlake, Texas. 3.7 Test Specimen Source: The test specimen(s) were provided by the client. Representative samples of the test specimen(s) will be retained by Architectural Testing for a minimum of four years from the test completion date. 3.8 Drawing Reference: The test specimen drawings have been reviewed by Architectural Testing and are representative of the test specimen(s) reported herein. Test specimen construction was verified by Architectural Testing per the drawings located in Appendix C. Any deviations are documented herein or on the drawings. 3.9 List of Official Observers: M Name Company w; Robert Muller Diamond Door Products Clint Barnett Architectural Testing, Inc. Architectural Testing 4.0 Test Specification(s): Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 2: 07/02/15 Page 3 of 12 ASTM E 1886-05, Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missiles) and Exposed to Cyclic Pressure Differentials ASTM E 1996-12, Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes 5.0 Test Specimen Description: 5.1 Product Sizes: 4, Test Specimens #1 - #3: Overall Area: 4.3 m2 146.41 ft2) Width Hei ht millimeters inches millimeters inches Overall size 1524 60 2829 111-3/8 Door Leaf, 1219 48 2416 95-1/8 5.2 Frame Construction: The frame head and jambs were steel and measured 10- 1/4" wide by 3" deep. Each door utilized a steel Z purlin anchored between the buck and the door frame at the center. The Z purlin was anchored to the buck utilizing a 2" x 1-1/2" steel angle. The steel angle was anchored to the buck with three 3/8" x 3" bolts while the other side of the angle was anchored to the Z purlin with three 3/8" x 3/4" bolts. The bottom jambs were anchored to the bottom buck with two 3/8" x 3" bolts. The top Z purlin was anchored into the jambs in the same manner that the intermediate Z purlins were. The jambs had a 10" x 20" long c- channel with one located at the top jambs and the other located 16" off the bottom. The C channel was anchored into the jambs with#8 x 1" self -taping screws every 12". The channel also utilized a bracket that was anchored to the Z purlin with two 3/8" x 3/4" bolts and the bracket anchored to the c channel with # 8 x 1" self - tapping screws on all four corners. The threshold was anchored to the wood buck with 1" tap cons spaced every 6".. A steel skin was placed along the exterior portions of the jambs and the head. The skin was anchored to the head and jambs using#8 x 1" self -tapping screws. 5.3 Panel Construction: The door leaf was constructed with a top and bottom skin having folded lock edges. The doors contained a bonded polystyrene core. Flush top and bottom channels were welded to both face sheets. Two lock boxes were projection welded to the lock stile of the door leaf. Test Report No.: E5450.02-801-44 Report Date: 05/31/15ArchitecturalTesting Revision 2: 07/02/15 Page 4 of 12 5.0 Test Specimen Description: (Continued) 5.4 Material Thickness Description Thickness Head and Jambs 0.062" Exterior steel skin 0.035" Door Panel Skin 0.030" C- Channel 0.062". Z-Purlins 0.109" 5.5 Weatherstripping: Description Quantity Location 1/4" high two finger rubber 1 Row Aluminum kerf attached to frame jambs and head 1" high one finger rubber 1 Row Aluminum kerf attached to leaf bottom exterior skin 5.6 Drainage Sloped Sill 5.7 Hardware: Description Quantity Location Door handle assembly with lock 1 Door leaf mid -point Strike plate 1 Door jamb Hinge 3 5.8 Reinforcement: No reinforcement was utilized. 6.0 Installation: The specimen was installed into a 2 x 12 Spruce -Pine -Fir wood buck. The exterior perimeter of the door was sealed with sealant. Architectural Testing 7.0 Test Results: The results are tabulated as follows: ASTM E 1886, Large Missile Impact Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 2: 07/02/15 Page 5 of 12 Conditioning Temperature: 2VC (70°F) Missile Weight: 4218 g (9.30 lbs) Missile Length: 2.44 m (8'0") Muzzle Distance from Test Specimen: 5.18 m (17'0") Test Unit #1: Orientation within ±5° of horizontal Impact 1: Missile Velocity: 15.24 m/s (50.00 fps) Impact Area Center of door leaf Observations: Missile hit target area, no ruptures or penetrations Results: Pass Impact #2: Missile Velocity: 15.51 m/s (50.90 fps) Impact Area Top right corner of door panel Observations: Missile hit target area, no ruptures or penetrations Results: Pass Test Unit #2: Orientation within ±5° of horizontal Impact #1: Missile Velocity: 15.42 m/s (50.60 fps) Impact Area Center of door leaf Observations: Missile hit target area, no ruptures or penetrations Results: Pass Impact #2: Missile Velocity: 15.48 m/s (50.80 fps) Impact Area Bottom left corner of door panel Observations: Missile hit target area, no ruptures or penetrations Results: Pass Note: See Architectural Testing Sketch #2 for impact locations. Test Report No.: E5450:02-801-44 Report Date: 05/31/15 Architectural Testing Revision 2: 07/02/15 Page 6 of 12 7.0 Test Results: (Continued) ASTM E 1886, Large Missile Impact Conditioning Temperature: 21°C (70°F) Missile Weight: 4218 g (9.301bs) Missile Length: 2.44 m (8'0") Muzzle Distance from Test Specimen: 5.18 m (17'0") Test Unit #3: Orientation within ±5° of horizontal Impact #1: Missile Velocity: 15.51 m/s (50.90 fps) Impact Area Bottom left corner of door leaf Observations: Missile hit target area, no ruptures or penetrations Results: Pass Impact 2: Missile Velocity: 15.24 m/s (50.00 fps) Impact Area Center of door leaf Observations: Missile hit target area, no ruptures or penetrations Results: Pass Note: See Architectural Testing Sketch #3for impact locations. Architectural Testing 7.0 Test Results: (Continued) ASTM E 1886, Air Pressure Cycling Test Report No.: E5450.02-801-44 ReportDate: 05/31/15 Revision 2: 07/02/15 Page 7 of 12 Test Unit #1 Design Pressure: +1035 Pa (+40.76 pso -871 Pa (-34.30 psO POSITIVE PRESSURE Pressure Range Number Average Cycle Time Observations Pa ( psf) of Cycles seconds) 486 to 1214 3500 1.62 No damage beyond the allowable 8. 20 to 20.40) 0 to 1457 300 1.94 No damage beyond the allowable 0 to 24.50 1214 to 1942 600 1.65 No damage beyond the allowable 20. 40 to 32.60) 728 to 2428 100 1.66 No damage beyond the allowable 12. 21 to 40.76) NEGATIVE PRESSURE Pressure Range Number Average Cycle Time Observations Pa ( psf) of Cycles seconds) 261 to 871 50 2.00 No damage beyond the allowable 10. 29 to 34.30) 436 to 697 1050 1.65 No damage beyond the allowable 17. 15 to 27.44 0 to 523 50 2.05 No damage beyond the allowable 0 to 20.60) 174 to 436 3350 1.52 No damage beyond the allowable 6. 86 to 17.15) Result: Pass Architectural Testing 7.0 Test Results: (Continued) ASTM E 1886, Air Pressure Cycling Test Report No.: E5450.02-801-44 ReportDate: 05/31/15 Revision 2: 07/02/15 Page 8 of 12 Test Unit #2 Design Pressure: +1035 Pa (+40.76 psi? -871 Pa (-34.30 pso POSITIVE PRESSURE Pressure Range Number Average Pa ( psf) of Cycles Cycle Time Observations seconds) 486 to 1214 8. 20 to 20.40) 3500 1.82 No damage beyond the allowable 0 to 1457 0 to 24.50 300 1.83 No damage beyond the allowable 1214 to 1942 20. 40 to 32.60) 600 1.65 No damage beyond the allowable 728 to 2428 12. 21 to 40.76) 100 1.77 No damage beyond the allowable NEGATIVE PRESSURE Pressure Range Number Average Pa ( psf) of Cycles Cycle Time Observations seconds) 261 to 871 10. 29 to 34.30) 50 2.00 No damage beyond the allowable 436 to 697 1050 1.65 No damage beyond the allowable 17. 15 to 27.44 0 to 523 0 to 20.60) 50 2.05 No damage beyond the allowable 174 to 436 6. 86 to 17.15) 3350 1.52 No damage beyond the allowable Result: Pass Architectural Testing 7.0 Test Results: (Continued) ASTM E 1886, Air Pressure Cycling Test Report No.: E5450.02-801-44 ReportDate: 05/31/15 Revision 2: 07/02/15 Page 9 of 12 Test Unit #3 Design Pressure: +1035 Pa (+40.76 psf) -871 Pa (-34.30 pso POSITIVE PRESSURE Pressure Range Number Average Pa ( psf) of Cycles Cycle Time Observations seconds) 486 to 1214 8. 20 to 20.40) 3500 1.62 No damage beyond the allowable 0 to 1457 0 to 24.50 300 1.94 No damage beyond the allowable 1214 to 1942 20. 40 to 32.60) 600 1.65 No damage beyond the allowable 728 to 2428 12. 21 to 40.76) 100 1.66 No damage beyond the allowable NEGATIVE PRESSURE Pressure Range Number Average Pa ( psf) of Cycles Cycle Time Observations seconds) 261 to 871 10. 29 to 34.30) 50 2.00 No damage beyond the allowable 436 to 697 17. 15 to 27.44 1050 1.65 No damage beyond the allowable 0 to 523 0 to 20.60) 50 2.05 No damage beyond the allowable 174 to 436 6. 86 to 17.15) 3350 1.52 No damage beyond the allowable Result: Pass Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Architectural Testing Revision 2: 07/02/15 Page 10 of 12 General Note: Upon completion of testing, the specimens met the requirements of Section 7 of ASTM E 1996. 8.OTest Equipment: Cannon: Constructed from steel piping utilizing compressed air to propel the missile Missile: 2A Southern Pine Timing Device: Electronic Beam Type Cycling Mechanism: Computer controlled centrifugal blower with electronic pressure measuring device Tape and film were used to seal against air leakage during structural testing. In our opinion, the tape and film did not influence the results of the test. r --. I Architectural Testingi Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 2: 07/02/15 Page 11 of 12 Architectural Testing will service this report for the entire test record retention period. Test records such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Architectural Testing, Inc. for the entire test record retention period. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen(s) tested. This report may not be reproduced, except in full, without the written approval of Architectural Testing, Inc. For ARCHITECTURAL TESTING, Inc. r Clint Barnett Technician CAB:hd a Tyler Westerling, P.E. Senior Project Engineer Attachments (pages): This report is complete only when all attachments listed are included. Appendix -A: Sketches (3) Appendix-B: Drawing (1) tltt 1 w'L .i . i.iili i i i Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Architectural re:"Q Revision 2: 07/02/15 Page 12 of 12 Revision Log Rev. # Date Pages) Revision(s) 0 05/31/15 N/A Original report issue 1 06/19/15 Cover Page Added Florida P.E. Seal. 1 06/19/ 15 " Page 11 2 07/02/15 Cover, 1 Replaced Andy Cost with Tyler Westerling. Change model# from 4070 to 4080 Architectural Testing Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 1: 06/19/15 Revision 2:07/02/15 Appendix A Sketches Test Specimen # I Impact locations 22L- Architectural Testing Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 1: 06/19/15 Revision 2:07/02/15 Test Specimen # 2 Impact locations Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Architectural Testing Revision 1: 06/19/15 Revision 2:07/02/15 td n rti P . Test Specimen 4 3 Impact locations Architecturai Testing Appendix B Drawing Test Report No.: E5450.02-801-44 Report Date: 05/31/15 Revision 1: 06/19/15 Revision 2:07/02/15 uMMIAMFOADE COUNTY i...0 ACCREDrTED E STEEL. ST R V C T V ' INC. METAL BUILDING MANUFACTURES ASSOCIATION LETTER OFCERTIFICATION VULCAN STEEL STRUCTURES, INC DATE: 08/29/17 Job Number 24934-2 , DESIGNED BY: VLB Customer Name: IRONROCK COMMERCIAL CONSTRUCT DETAILED BY: KD Job Location: SANFORD, FL 32771 CHECKED BY: BCP DESIGN PARAMETERS COMMENTS BUILDING DESCRIPTION: PIPE STANDS TO SUPPORT 4,620# NOMINAL WIDTH: 38.92 feet ROOF UNITS (1 PER BAY) NOMINAL LENGTH: 79.5 feet EAVE HEIGHT, BACK S.W: 35.86 feet AIR UNITS HANGING BELOW ROOF: EAVE HEIGHT, FRONT S.W: 36.67 feet 1,600# PER UNIT (2 UNITS PER BAY) ROOF SLOPE, LEFT: 0.25:12 ROOF SLOPE, RIGHT: DESIGN LOADS BUILDING CODE: FLORIDA BUILDING CODE 5TH EDITION (2014) - BUILDING FRAME SELF WEIGHT: INCLUDED SNOW ROOF DEAD, LOAD: 6.500 psf FLAT ROOF SNOW LOAD ,Pf 0 psf COLLATERAL LOAD: 5 psf GROUND SNOW LOAD Pg 0.00 psf. ROOF ' LIVE LOAD::. 20.00 psf SNOW LOAD IMP. FACTOR 1.00 FRAME LIVE LOAD: 13.23 / 12 psf THERMAL FACTOR, Ct. 1:00 SNOW LOAD, ROOF: 0 psf SNOW EXP. FACTOR Ce 1.00 WIND SPEED: (3 SEC GUST) 140 mph (Vult) 108. 4 mph (Vasd) INTERNAL PRESSURE COEFF. 0.18/ 0.18 WIND EXPOSURE: B CLOSURE " C, 0, P" Closed RISK CATEGORY II - Normal SEISMIC PARAMETERS SEISMIC - FORCE RESISTING SYSTEM: STEEL ORDINARY MOMENT FRAME ANALYSIS PROCEDURE EQUIVALENT LATERAL, FORCE PROCEDURE SITE CLASS (ASSUMED) D , SEISMIC IMPORTANCE: 1.00: ' SEISMIC DESIGN CATEGORY: A DESIGNED SPECTRAL ACCELERATION PARAMETER "SDS=''. - (SHORT PERIODS): 0.09 DESIGNED SPECTRAL ACCELERATION PARAMETER "SD1" - (1 SEC PERIODS): 0.06 MAPPED SPECTRAL RESPONSE ACCELERATION SS" - (SHORT PERIODS): 0.08 MAPPED SPECTRAL RESPONSE ACCELERATION S1" - (1 SEC PERIOD): 0.04 SEISMIC RESPONSE MODIFICATION COEFFICIENT. R" 3.5 SEISMIC RESPONSE COEFFICIENT: "Cs" - 0.029 TOTAL LONGITUDINAL BASE SHEAR 1.42 TOTAL TRANSVERSE BASE SHEAR 1.44 DRAWING RELEASE HISTORY DRAWING REVISIONS DATE SENT REASON FOR RELEASE REVISION DATE BY DESCRIPTION A B C D COVERING AND TRIM COLOR TABLE SHEETING ROOF PANEL: GAUGE PANEL TYPE COLOR 22 GA. B" DECK GALVANIZED FLORIDA PRODUCT APPROVAL NUMBERS W A L K D 0 0 R S 3070/ 4070 IMPACT RATED WIND RATED & KNOCKDOWN OR PRE -ASSEMBLED FL17900.1 3070/ 4070 NON -IMPACT RATED WIND RATED & KNOCKDOWN OR PRE -ASSEMBLED FL17900.2 6070/ 8070 IMPACT RATED WIND RATED & KNOCKDOWN OR PRE -ASSEMBLED FL18463.2 6070/ 8070 NON -IMPACT RATED WIND RATED & KNOCKDOWN OR PRE -ASSEMBLED FL18463.1 R I D G E V E N T S 12" THROAT RIDGE VENT WITH 12" THROAT FL12805.2 6- 3/4" THROAT RIDGE VENT WITH 6-3/4" THROAT FL12805.5 9" THROAT. RIDGE VENT WITH 9" THROAT FL12805.1 L O U V E R S FIXED GLASS LOUVER WITH FLIXED GLASS FL12256.1 ADJUST. GLASS ILOUVER WITH ADJUSTABLE GLASS FL12256.2 R O; L L U P D 0 0 R S 1100 SERIES MAX SIZE: 8'-8" X 14'-0" FL12765.1 1100 SERIES MAX SIZE: 10'-0" X 14'-0" FL12765.2 3100 SERIES MAX SIZE: 12'-0" X 20'-0" FL12765.3 3100 SERIES - MAX SIZE: 20'-0" X 20'-0" FL12765.4 750 SERIES MAX SIZE: 3'-0" X 12'-0" FL12675.5 750 SERIES MAX SIZE: 6'-0" X 12'-0" FL12765.6 750 SERIES' MAX SIZE: 8'-8" X 12'-0" FL12765.7 750 SERIES MAX SIZE: 10'--0" X 12'-0" FL12765.8 R 0 0 F P A N E L S BATTENLOK FL11819.1 DOUBLE- LOK FL11819.2 LOKSEAM FL11819.3 SUPERLOK FL11819.4 ULTRA- DEK FL11819.5 7. 2 PANEL FL1519.1 , PBR PANEL FL5346.1 PBU PANEL FL11868.2 W A L L P A N E L S AVP PANEL FL11917.3 FW- 120 PANEL FL11917.4 PBR PANEL FL5335.1 REVERSE PBR FL5335.1 SHADOWRIB PANEL FL11917.6 S 0 F F I T P A N E L S ARTISAN L-12 FL11919.1 S K Y L I G H T S PBR SKYLIGHT FL13793 W A L L L I T E S PBR I FL13787.1 BLDG# 2 BLDG#1 KEY PLAN MIAMI DADE PRODUCT APPROVAL NUMBERS R 0 L L U P D 0 0 R S 850 SERIES MINI MAX SIZE: 8'-8" X 12'-0" NOA-13-1203.05 3400 SERIES MAX SIZE: 12'-0" X 20'-0" NOA-13-0124.05 R 0 0 F P A N E L S PBR 122 GAGE & 24 GAGE NOA-12-0730.02 SUPERLOK 22 GAGE NOA-12-0911.02 SUPERLOK 24 GAGE NOA-12-0123.07 DOUBLE- LOK NOA-13-0425.14 W A L L- P A N E L S PBR 24 GAGEv, NOA-12-0123.06 ECO- FICIENT NOA-14-0306.03' S K Y L I G H T S PBRI NOA-12-0110.04 THE PROJECT DESIGNER IS NOT THE METAL BUILDING MANUFACTURER, THE METAL BUILDING. DESIGNER OR THE METAL BUILDING ENGINEER. THE ENGINEER WHOSE SEAL APPEARS ON THE METAL BUILDING PLANS IS A SPECIALTY ENGINEER AND NOT THE PROJECT DESIGNER OR THE PROJECT ENGINEER OF RECORD. THE ENGINEER WHOSE SEAL APPEARS ON THE METAL BUILDING PLANS DOES NOT HAVE FAMILIARITY WITH THE PHYSICAL JOBSITE LOCATION AND THEREFORE CANNOT BE IDENTIFIED AS, SERVE AS OR QUALIFY AS THE PROJECT DESIGNER. WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 V 4gTppp,ARKWAY O. No. 61323ae O o STATE OF _ v 0W//1RIGINAL SIGNATURE REQUIRED 41 A. GENERAL NOTES 1. MATERIALS ASTM DESIGNATION STRUCTURAL STEEL PLATE A529 OR A572 GRADE 50 or GRADE 55 COLD FORMED LIGHT GAGE SHAPES A1011 GRADE 55 BRACE CABLES A475 EHS HOT ROLLED MILL SHAPES ASTM A992 GRADE 50 ROOF AND WALL SHEETS A653 OR A792 GRADE 50 or GRADE 80 BOLTS A307, A325T, AND A490 A307 UNLESS NOTED 2. STRUCTURAL PRIMER SHOP PRIMER PAINT IS A MINIMAL NON —UNIFORM THICKNESS COATING OF A RUST INHIBITIVE RED —OXIDE COLOR PRIMER SATISFYING THE REQUIREMENTS OF TT—P-664. THIS PRIMER IS NOT TO BE CONSIDERED A FINISH COAT AND IS NOT INTENDED FOR LONG TERM EXPOSURE TO THE ELEMENTS. THIS PRIMER IS NOT WARRANTED OR REPRESENTED AS BEING COMPATIBLE WITH ANY TYPE OF FINISH PAINT SYSTEM. THE PRIMER COAT APPLIED AT THE FACTORY IS SUBJECT TO BLEMISHES, SCUFFS, SCRATCHES AND THE LIKE DURING SHIPPING AND DURING HANDLING AS PART OF THE ERECTION PROCESS. IT IS THE RESPONSIBILITY OF THE ERECTOR TO TOUCH UP ANY SUCH UNDESIRABLE CONDITIONS DURING OR AFTER THE ERECTION PROCESS. OBJECTIONS TO PRIMER APPEARANCE SHALL NOT BE SUBJECT TO REJECTION OR BE CONSIDERED A CAUSE FOR REJECTION. 3. A325 BOLT TIGHTENING REQUIREMENTS ALL HIGH STRENGTH BOLTS ARE A325T UNLESS SPECIFICALLY NOTED OTHERWISE. STRUCTURAL BOLTS SHALL BE TIGHTENED BY THE TURN —OF —THE —NUT METHOD IN ACCORDANCE WITH THE 14th EDITION AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325T OR A490 BOLTS". PER SECTION 8.1, (SPEC. 16.2) A325T BOLTSMAY BE INSTALLED WITHOUT WASHERS WHEN TIGHTENED BY THE TURN —OF —THE NUT METHOD. ALL HIGH STRENGTH BOLTS, EXCEPT AS NOTED OTHERWISE, ARE SUBJECT TO DIRECT TENSION AND MAY REQUIRE INSPECTION AS DEFINED BY THE APPLICABLE BUILDING CODE OR STANDARD. IT IS THE RESPONSIBILITY OF THE ERECTOR TO ASSURE PROPER TIGHTNESS. 4. BUILDER/CONTRACTOR RESPONSIBILITIES THE METAL BUILDING MANUFACTURER'S STANDARD PRODUCT SPECIFICATIONS APPLY AND UNLESS STIPULATED OTHERWISE IN THE CONTRACT DOCUMENTS, THE METAL BUILDING MANUFACTURER'S DESIGN, FABRICATION, QUALITY CRITERIA STANDARDS AND TOLERANCES WILL GOVERN THE WORK. IN CASE OF DISCREPANCIES BETWEEN METAL BUILDINGS MANUFACTURER STRUCTURAL PLANS AND PLANS FOR OTHER TRADES. THE METAL BUILDING MANUFACTURER'S PLANS SHALL GOVERN. IT IS THE RESPONSIBILITY OF THE BUILDER / CONTRACTOR TO OBTAIN APPROPRIATE APPROVALS AND NECESSARY PERMITS FROM CITY, COUNTY, STATE, OR FEDERAL AGENCIES, AS REQUIRED. APPROVAL OF METAL BUILDING MANUFACTURER'S DRAWINGS CONSTITUTES THE BUILDER / CONTRACTOR'S ACCEPTANCE OF THE METAL BUILDING MANUFACTURER'S INTERPRETATION OF THE CONTRACT PURCHASE ORDER. ONCE THE BUILDER / CONTRACTOR OR A/E FIRM HAS SIGNED MANUFACTURER'S APPROVAL PACKAGE, CHANGES FROM THE PURCHASE ORDER BY THE BUILDER WILL BE BILLED TO THE BUILDER / CONTRACTOR FOR MATERIAL, ENGINEERING AND HANDLING FEES. SUCH CHANGES MAY CAUSE THE PROJECT TO BE MOVED FROM THE FABRICATION AND OR SHIPPING SCHEDULE. A PENALTY FEE MAY BE CHARGED IF THE PROJECT MUST BE MOVED FROM THE FABRICATION AND / OR SHIPPING SCHEDULE, AS LONG AS THE MANUFACTURER'S DESIGN AND DETAILING APPROACH COMPLIES WITH THE PURCHASE ORDER. THE BUILDER / CONTRACTOR OR A/E FIRM ARE RESPONSIBLE FOR THE OVERALL PROJECT CONDITION. ALL INTERFACE AND COMPATIBILITY CONCERNING ANY MATERIALS NOT FURNISHED BY THE MANUFACTURER ARE TO BE CONSIDERED AND COORDINATED BY THE BUILDER / CONTRACTOR OR A/E FIRM. UNLESS SPECIFIC DESIGN CRITERIA CONCERNING THIS INTERFACE BETWEEN MATERIALS IS FURNISHED AS PART OF THE PURCHASE ORDER. THE METAL BUILDING MANUFACTURER'S ASSUMPTIONS WILL GOVERN. THE BUILDER / CONTRACTOR IS RESPONSIBLE TO INSURE THAT ALL OTHER PROJECT PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE REQUIREMENTS OF ANY GOVERNING BUILDING AUTHORITY. SUPPLYING SEALED ENGINEERING DESIGN DATA AND DRAWINGS BY THE BUILDING MANUFACTURER .DOES NOT IMPLY OR CONSTITUTE AN AGREEMENT THAT THE BUILDING MANUFACTURER OR ITS DESIGN ENGINEER IS ACTING AS THE ENGINEER OF RECORD OR DESIGN PROFESSIONAL FOR THE CONSTRUCTION PROJECT. THESE DRAWINGS AND DESIGN DATA ARE SEALED AS TO THE STRUCTURAL SYSTEM FURNISHED BY THE METAL BUILDING MANUFACTURER IN COMPLIANCE WITH ALL REQUIREMENTS OF THE PURCHASE ORDER. THE BUILDER / CONTRACTOR IS RESPONSIBLE FOR SETTING OF ANCHOR BOLTS AND ERECTION OF STEEL BUILDING COMPONENTS IN ACCORDANCE WITH THE METAL BUILDING MANUFACTURER'S "FOR CONSTRUCTION" DRAWINGS. TEMPORARY SUPPORTS OR BRACING REQUIRED FOR THE BUILDING ERECTION WILL BE THE RESPONSIBILITY OF THE ERECTOR TO DETERMINE, FURNISH, AND INSTALL. THE METAL BUILDING MANUFACTURER DOES NOT WARRANT STRUCTURAL INTEGRITY OF ANY COMPONENTS FIELD MODIFIED OR DESIGNED AND FABRICATED BY OTHERS. NEITHER DO WE ACCEPT DESIGN RESPONSIBILTY FOR THE EFFECTS NON STANDARD COMPONENTS DESIGNED BY OTHERS MAY HAVE ON THE SYSTEM IN GENERAL. AS TAKEN FROM THE FOURTEENTH EDITION OF THE AISC MANUAL PAGE 16.3-56 PARAGRAPH 7.14 — READS AS FOLLOWS THE CORRECTION OF MINOR MISFITS BY MODERATE AMOUNTS OF REAMING, GRINDING, WELDING OR CUTTING, AND THE DRAWING OF ELEMENTS INTO LINE WITH DRIFT PINS, SHALL BECONSIDERED TO BE NORMAL ERECTION OPERATIONS." RECOGNIZING THE FLORIDA BUILDING CODE REQUIRES EXPOSURE C AS THE DEFAULT WIND EXPOSURE. IT IS RESPONSIBILITY OF THE PROJECT DESIGNER TO DETERMINE, VERIFY AND PROVE EXPOSURE "B" IS APPLICABLE BASED ON THE BUILDING LOCATION AND THAT EXPOSURE B IS ACCEPTABLE TO LOCAL BUILDING/CODE OFFICIALS OR AUTHORITIES HAVING JURISDICTION. IT IS THE ABSOLUTE RESPONSIBILITY OF THE BUYER TO RETAIN SERVICES OF AN INDIVIDUAL OR FIRM PROPERLY QUALIFIED TO PERFORM THE DUTIES REQUIRED OF A PROJECT DESIGNER TO INCLUDE: A PROJECT DESIGNER IS RESPONSIBLE FOR DETERMINING THE SITING OF (DETERMINATION OF WIND EXPOSURE) AND SPECIFYING THE GEOMETRY, LOADS AND MATERIALS FOR A BUILDING PROJECT. A PROJECT DESIGNER IS RESPONSIBLE FOR DETERMINING GEOMETRY PARAMETERS INCLUDE DEFINITION OF WIDTH, LENGTH, HEIGHT, SLOPE, BAYS, INGRESS AND EGRESS REQUIREMENTS AS APPLICABLE AND NECESSARY FOR THE DESIRED OCCUPANCY USAGE CATEGORY. A PROJECT DESIGNER IS RESPONSIBLE FOR DETERMINING LOAD PARAMETERS INCLUDING DEFINITION OF THE BUILDING CODE AND APPLICABLE EDITION (YEAR), DETERMINATION OF IMPORTANCE FACTORS, DEFINITION OF ALL LOADS REQUIRED FOR THE DESIGN OF THE STRUCTURE INCLUDING DEAD LOADS, COLLATERAL LOADS, LIVE LOADS, WIND SPEED AND EXPOSURE. CATEGORY, HVAC UNIT LOADS, FLOOR AND OTHER APPLIED LOADS (IF APPLICA— BLE). NEITHER THE METAL BUILDING MANUFACTURER OR THE METAL BUILDING ENGINEER ARE RESPONSIBLE FOR LOAD OR EXPOSURE CATEGORY DETERMINATION. A PROJECT DESIGNER IS RESPONSIBLE FOR DETERMINING MATERIAL PARAMETERS INCLUDE DEFINITION OF ALL EXTERIOR COVERING MATERIALS AS WELL AS ALL INTERIOR SURFACES AND FINISHES. SPFCIAI NOTFS- BUILDING IS NOT STRUCTURALLY SOUND UNTIL ALL WALL COVERING, ROOF SHEETS, AND PERMANENT BRACING IS INSTALLED. BUILDER / CONTRACTOR IS RESPONSIBLE FOR SUPPORTS OR TEMPORARY BRACING DURING ERECTION, HE SHALL FURNISH, AND INSTALL THESE TEMPORARY SUPPORTS WHERE NECESSARY. TEMPORARY SUPPORTS ARE NOT PROVIDED BY THE METAL BUILDING MANUFACTURER. OUTSIDE VENDOR ACCESSORY NOTE: BUYER SHALL BE RESPONSIBLE TO COORDINATE, ASSURE AND VERIFY THAT THE STRUCTURE AND CLEARANCES AS PROVIDED BY BUILDING MANUFACTURER ARE COMPATIBLE WITH THE DOOR PROVIDED BY OTHERS. TUBE GUTTER TRIM VARIES) p STANDARD TRIM LAP DETAIL b NOTE: ALL TRIM CONTAINED ON THIS PROJECT, WILL HAVE OUR STANDARD 3" LAP AS SHOWN. ABOVE. (TRIM STYLE VARIES) BLDG#2 BLDG#1 KEY PLAN THE PROJECT DESIGNER IS NOT THE METAL BUILDING MANUFACTURER, THE METAL BUILDING DESIGNER OR THE METAL BUILDING ENGINEER. THE ENGINEER WHOSE SEAL APPEARS ON THE METAL BUILDING PLANS IS A SPECIALTY ENGINEER AND NOT THE PROJECT DESIGNER OR THE PROJECT ENGINEER OF RECORD. THE ENGINEER WHOSE SEAL APPEARS ON THE METAL BUILDING PLANS DOES NOT HAVE FAMILIARITY WITH THE PHYSICAL JOBSITE LOCATION AND THEREFORE CANNOT BE IDENTIFIED AS, SERVE AS OR QUALIFY AS THE PROJECT DESIGNER. WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULQAhL. PARKWAY cc '•• .0' 0.61323 o STATE OF •:'; ORIGINAL SIGNATURE REQUIRED MCHOR BOLT NOTES: HICK NUT W/FLAT WASHER\ SEE BUILDING PLANS ANCHOR BOLT SUMMARY _ MANUFACTURER RECOMMENDS USE OF STRAIGHT ROD ANCHOR BOLTS CONCRETE LINE \\ FOR PROJECTION wRIS HNUTANDWHERON BOTH ENDS AS OPPOSED TO J-BOLTS OR Total ANCHOR BOLTS WHH HOOKS BECAUSE OF BETTER PERFORMANCE Dia Len Pfaj RESULTS IN CONCRETE FOUNDATIONS. ETHER TYPE BOLT IS Qty Locate (I n) (In) (In) ACCEPTABLE AS DETERMINED BY THE FOUNDATION ENGINEER. ANY Z 9• DOOR JAMBS 5/8" DIA VALUESGNFNFORANCHORBOLTTOTALLENGTHSAND/OR BEND LENGTHS ME SUGGESTED LENGTHS ONLY. R IS THE RESPONSIBILITY 0 8 Endwall 5/8" 15.0 3.00 15' FOR ALL OTHER 5/8' OIA h DOOR THEY THEEA FUNCTION ENGINEER R DETERMINE THESE OTHER SINCE 0 120 Frame 3/4" 24.0 3.00 1HEY ME A NNCTION OF CONCRETE STRENGTH AND OTHER FACTORS. O JAMBS ACTING 15 E.W. COLUMNS HI NUT « 24" ALL OTHERS W/FLAT WAS ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36 (Ml OR GRADE 55' ANCHOR BOLTS 279'- 0" 15 79'- 6"STEEL LINE TO STEEL LINE 199'-6"STEEL LINE TO STEEL LINE 26'- 6". 26'-0" T-O' 20'-0" 20'-0' 7 14 20'- 0" 20'-O" 20'-0" 20'-0" 20"-0" 20'-0" 20'-0" 19'-6" 4: 5 8" 25'-10' - 26'-4" 8" 8" 19'-4" - 1W-10" 8" Low Eave 2" 2 _ 2. 2" 2. 2^ - 2. 2' i6 2" 2" 2" 2" 2" 2• 2" 2" 212 2" 2" 212 212 2" 2" 2' 2" Low E.- G- Wind -Bent Wind -Bent Wind -Bent A r" z w 0 J B w ni. C Wind - Bent Wind -Bent Wind -Bent _ _ C High Eave 2" 2" 2" 2" 2" 2" 2' 2" T8_ 2" 2" 2".2" 2" 2" 2" 2" 2" 2" 2" 2" Y 2" 2" 2" - 2" 2" 2 2 High Eave8" 25'-10" 6'-4" 8"" 19'-4" ,8'-10" 8' 4 5 26'- 6" 26'-0" 27'-0" 20'-0" 20'-0" 20'-0" 20'-0' 20'-0" 20'-0' 20'-0" 20'-0" 20,-0" 19'-6" FRAME LINE - DIMENSIONS 1 2 3 6 7 8 9 10 - 11 1 1:i T4 15 ANCHOR BOLT PLAN NOTE: All Base Plates ® 100'-0" (U.N.) 1 — 3H WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY UIII i1g4 n NO. 61323 SEE PLAN - a OUT TO our CONCRETE I L PANOL— FIELD LOCATED OPENINGS SEEPLAN _ i OUT T. OUT STEEL ®Y OTHERS) OTY DESCRIPTIONI BLDG# Z BLDG#1 ; STATE ,. w INSIDE. CLOSURE (OPTIONAU 3 3'-4'x7'-2' F.. '0 . 4..' c4 Pfif PROJECTION '' G• I BASE ANGLE 'f( p f i1Lryt,n}H, f f t 2' x4'x16GA. FINISHED FLOORKEY PLAN / /7J N444444tso%%+t, ORIGINAL SIGNATURE REQUIRED REVISIONS DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTI N 1/ 4' x I' REV. DESCRIPTIDNI DATE DTLR DATE CHKR APPD E I FINAL ERECTION PROJECT THE FATHER'S TABLE ANCHOR BOLT PLAN NAIL - IN ANCHOR ID 24934-2 DESIGN- VLB DRAFTS KD CHECKI PMS 2 36' O.C. (BY OTHERS) EX] FOR CONSTRUCTION E I FOR APPROVAL PROJECT DATE108/28/17 SHEET .1 OF 18 rnNCRFTF FD AND ANCHOR R 1 T PRO 1 TI N BASE WITHOUTSHEETING NOTCHTRIH E I THER, EXPLAIN SANFORD, FL 32771 ADDRESS 1. N ", m tn male •m Wm m a s w $ m m 0.1 a I' F1._ S F1 p I E7 D LEI 0 E u E E ); E ; E > E > E E o E D I b v\ i a h o E BLDG#2 E BLDG#1 ro n B A, Dev 99'-6' A« I I Dew 99'-6" 1 C1 ° D, aID19g7> eeiC1gO7 8.. I C > alCo C a iCn , aC , Cfe , C e tCn , CIa Q 4 Tr--.. COLUMN LINE H ENDWALL COLUMN: BASIC COLUMN REACTIONS (k ) Wind Wind Frm Col Press Suct E1PAT_LL-1- E1PAT_LL-2- Line Line Harz Horz Horz Vert Harz Vert 1 B -9.3 10.2 0.0 3.1 0.0 3.1 BUILDING BRACING REACTIONS t Reactions(k) Panel Shear Wall - Col -Wind - -Seismic- (lb7ft) Loc Line" Line Horz Vert Horz Vert Wind Seis Note F-SW C 2,3 3.0 8.2 0.4 1.0 b R-EW 4 h B-SW A 2,3 3.0 7.9 0.4 0.9 b b Wind bent in bay, base above finish floor h Rigid frame at endwoll 2 3 4 H QCOLUMN LINE V RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc._Bolt Base -Plate (n Elev. Line Line Qty Dia Width Length hick in) 1 A 4 0.750 8.000 14.75 0.500 6.0 1 C 4 0.750 8.000 17.00 0.500 6.0 1 B 4 0.625 6.000 13.00 0.500 6.0 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc._Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 2* A 4 0.750 8.000 20.00 0.500 -6.0 2* C 4 0.750 10.00 20.00 0.500 -6.0 2* Frame lines: 2 3 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc._Bolt Base -Plate (in Elev. Line Line Qty Dia Width Length hick in) 4 A 4 0.750 8.000 14.75 0.500 6.0 4 C 4 0.750 8.000. 17.00- 0.500 6.0 GENERAL NOTES 1.) APPLICATION OF ENGINEERS SEAL IS FOR METAL BUILDING ONLY AND DOES NOT REPRESENT THEPROFESSIONALOF RECORD. 2.) FOUNDATION DESIGN AND CONSTRUCTION ARE NOT THE RESPONSIBILITY OF THE MEYAL BUILDING MANUFACTURER. 3.) ANCHOR BOLTS SHALL BE ACCURATELY SET TO A TOLERANCE OF +/- 1/8"IN BOTH _ ELEVATION AND LOCATION. 4.) THE BUILDING REACTION DATA REPORTS THE LOADS WHICH THIS BUILDING PLACES aN THE FOUNDATION. THE FOUNDATION IS TO BE DESIGNED BY A QUALIFIED ENGINEER TO SUPPORT THE BUILDING REACTIONS IN ADDITION TO OTHER LOADS IMPOSED BY THE BUILDING USE OR OCCUPANCY WITH RESPECT TO JOB SITE CONDITIONS. 5.) ALL ANCHOR BOLTS TO BE ASTM F1554 GRADE 36 MIN. OR GRADE 55.(UNLESS NOTED) 6.) VALUES GIVEN FOR BENDS AND ANCHOR BOLT TOTAL LENGTHS ARE SUGESTED LENGTHS ONLY. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO DETERMINE THESE VALUES SINCE THEY ARE A FUNCTION OF CONCRETE STRENGTH AS WELL AS OTHER FACTORS. 7.) WIND REACTIONS ARE BASED ON Vult DESIGN LOAD DEFINITIONS RIGID FRAME LOAD CASE DEFINITIONS Wlncl_ Ll/Wlnd_Rl = Lateral wind load from the left/right with o negative Internal pressure cofficlent. Wlnd_ L2/Wlnd_R2 = Lateral wind load from the left/right with a positive Internal pressure cofficient. Wlnd- Lnl = Longitudinal wind load with a negative Internal pressure coefficient. Wind_ Ln2 = Longitudinal wind load with a positive Internal pressure coefficient. Seisrtic_ L/SPismlc_R =-Lateral Selsmic load from left/right, LWIND#_ L#E/ LWIND#_R#E = Longltudlnal wind loads for edge zones. F# UNB_SL_L/ F#UNB_SL_R = Unbalanced roof snow load with wind from the left/right. F# PAT_LL # = Pattern live load for continuous bears systems. Note, Bracing reactions .are not already Included In combination with any other load but must be added to basic reactions as desired by the foundation designer.' Cotlat = Collateral Load Endwall Load Case Definitions Rafter Wind_L/ Rafter Wlnd R = Lateral wind load from the left/right. Brace Wind_L/ Brace Wlnd_R = Lateral wind load from the left/rlght with the bracing loads added. Wind_ P/Wlnd_S = Wind Pressure/Suctlon due to longitudinal wind, Wlnd- Ln#. = Longitudinal wind load on the roof. Seismlc_ L/SeismIc_R = Lateral Seismic load from left/right. E# UNB_SL_L/ E#UNB_SL_R = Unbalanced roof snow load with wind from the left/right. E# PAT_LL # = Pattern live load for continuous beam systems. LWIND#- L/LWIND#_R = Longltudlnal wind loads for edge zones. VISIONS V T DESCRIP RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column Dead- ----Collateral- Live ------ Wind_Leftl- Wind_Rightl- Wind-Left2- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 1 A 0.0 1.8 0.1 1.5 0.0 1.6 5.6 7.2 7.1 0.0 8.5 5.5 1 C 0.0 2.4 0.1 1.9 0.0 1.6 5.9 8.8 7.2 18.8 7.4 13.7 1 8 0.0 3.4 0.0 6.3 0.0 4.0 0.0 22.8 0.0 6.7 0.0 23.4 Frame Column Wind_Right2- Wind-Longl- Wind_Long2- Seismic Left Seismic Right F1PAT_LL_l- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 1 A 4.2 1.8 5.3 5.2 5.3 5.2 0.1 0.1 0.1 0.1 0.0 1.7 1 C 5.7 13.9 2.9 11.5 2.9 11.5 0.2 0.4 0.2 0.4 0.0 0.1 1 B 0.0 6.2 0.0 4.5 0.0 4.5 0.0 0.3 0.0 0.3 0.0 2.0 Frame Column F1 PAT-LL-2- Line Line Horiz Vert 1 A 0.0 0.1 1 C 0.0 1.7 1 B 0.0 2.0 Frame Column Dead -----Collateral- Live ------ Wind_Leftl- Wind-Rightl- Wind_Left2- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 4 A 0.2 3.1 0.5 4.6 0.3 3.6 7.3 18.7 7.6 3.4 10.2 17.2 4 C 0.2 3.7 0.5 5.0 0.3 3.6 4.2 2.6 6.7 15.5 5.7 2.1 Frame Column Wind_Right2- Wind-Longl- Wind_Long2- Seismic-Left Seismic Right Line Une Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 4 A 4.7 4.9 4.9 7.5 4.9 7.5 0.1 0.3 0.1 0.3 4 C 5.3 10.8 3.2 13.7 3.2 13.7 0.2 0.3 0.2 0.3 Frame Column Dead -----Collateral- Live ------ Wind -Left 1- Wind_Rightl- Wind_Left2- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* A 0.5 5.3 1.3 9.5 0.7 6.1 10.3 25.8 12.6 5.8 16.1 23.1 2* C 0.5 5.7 1.3 10.2 0.7 6.1 4.6 2.2 8.7 23.5 6.9 6.7 Frame Column Wind-Right2- Wind_Longl- Wind_Long2- Seismic-Left Seismic Right Line Line Horiz Vert Horiz Vert - Horiz Vert Horiz Vert Horiz Vert 2* A 6.8 8.6 9.9 8.5 9.9 8.5 0.2 0.4 0.2 0.4 2* C 6.3 14.7 4.6` 19.5 4.6 19.5 0.2 0.4 0.2 0.4 2* Frame lines: 2 3 WIND LOADING PRESSURES CHART AREA <= 10 SQ.FT. FOR PAN GLVAUELSIFORVOUSLT E VOD E NEGT VE VEGGSATNE ZONE 1 (ROOF INTERIOR) 15 10 37 22 ZONE 2 (ROOF EDGE) 15 10 63 38 ZONE 3 (ROOF CORNER) 15 10 94 56 ZONE 4 (WALL INTERIOR) 34 21 37 22 ZONE 5 (WALL EDGE) 34 21 45 27 3070 34 21 37 22 NOTE i USE MAXIMUM STATED WALL PRESSURES FOR WINDOWS, LOUVERS, OR ANY OTHER SUCH TYPE ACCESSORY PENING IN THE METAL BUILDING WALL WHETHER R NOT THE ACCESSORY IS SUPPLIED BY THE METAL BUILDING MANUFACTURER, BLDG# 2 BLDG#1 KEY PLAN VULCAN STEEL STRUCTURES, INC I 1 FINAL ERECTION PROJECT THE FATHER'S TABL EXI FOR CONSTRUCTION ID 24934-2 I 1 FOR APPROVAL PROJECT SANFORD, FL 32771 11OTHER, EXPLAIN ADDRESS WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 tptptnt n n nnrrnprzr`.. AFL E . 0, GENSF• .O' N61323 0. STATEOF : cc i ..*• 4 FSS1D N AV 0/21NAL SIGNATURE REQUIRED IRONROCK COMMERCIAL CONSTRUCTIO DESIGN, VLB I DRAFT, KD DATE-0 / 28/17 SHI Dia= 5/8" .Dia= 3/4" j— j o f 8 —I i I F I I o 010 L15/8" 4° OI0 @ I_ 4" 1 5/8" EW SW 1 3/4" 1 3/4" 2" 2" See Plan See Plan DETAIL A Base EL. 99'-6" DETAILE Base EL. 99'-6" Dia= 3/4" BLDG'# 1 4" 4 SW 2" T2 " 8DETAIL B Base EL. 99'-6" Dia= 3/4" r l DETAIL C Base EL. 99'-6" Dia= 3/4" w 8 1- 74" 1 5/8" SW DETAIL D Base EL. 99'-6" I Ig Dia= 5/8" j a f0 9 e Dia= 3 w3/ 4° 010 4„ 4010 1 5/8" 1 5/8" EW 1 3/4"' 1 3/4• SW 2" 2" See Plan 8.. DETAIL Al Base EL. 99'-6" DETAIL E1 Base EL. 99'-6" Dia= 3/4" Dia= 3/4" w I I 8" to& 4» 4" 4. 4.. 1 5/8" SW SW See Plan DETAIL Cl Base EL. 99'-6" DETAIL F1 Base EL. 99'-6" Dia= 3/4" lo" 4" I— 4" SW 2" 2.. See Plan DETAIL D1 Base EL. 99'-6" REVISI NS REV, I DESCRIP WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 Unrururuernhrr,, r 0. 61323 ^ C e BLDG# 2 BLDG#1 STATE OF n p 5pr cl re' tt KEY PLAN ORI INAL SIGNATURE REQUIRED' DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION E I FINAL ERECTION PROJECT THE FATHER'S TABLE ANCHOR BOLT DETAILS EX] FOR CONSTRUCTION ID 24934-2 DESIGN-VLB I DRAFT KD CHECK PMS E I FOR APPROVAL E I OTHER, EXPLAIN PROJECT SANFORD, FL 32771 DATE 08/29/17 SHEET 3 ADDRESS SPLICE BOLT TABLE CAP PLATE BOLTS MEMBER TABLE TYP, FLANGE BRACE / GIRT C NNECTI N Web De th Web Plate Outside Flange Qty DFFSET nL Mark Start End Thick Len th W x Thk x Length Mark Top Bot Int Type Dia Length Mark Qty Type Dia Length 2'SE 1/2'xl 1/4 A307 BOLTS RF1-101 14.0 14.0 0.135 164.7 6 x 5 t6 x 228.0 SP-1 4 4 0 A325T 0.625 2.25 EC-101 4 A325T 0.625 2.25 TYP. U.N.) TYP, U.N.) 14.0/14.0 0.135 240.0 6 x 5/16" x 197.5 SP-2 4 4 0 A325T 0.875 3.50 I ° 14.0/14.0 0.188 21.0 6 x 5/16" x 15.9 o I RF1-102 W18X35 FLANGE BRACE TABLE FRAME. LINE 1 D ID SIDES MARK LENGTH OFFSET 1 1 FB41A 3'-5" 2'-8" 2 1 FB37.5A 3'-1 1/2" 2'-8" GENERAL NOTES: NOTICE TO ERECTOR A)lt is IMPORTANT that for members exceeding 30 ft. in length that a spreader bar be used when lifting. B)ALL flange braces and wind bracing must be installed prior to exterior finishes being applied. RF1-103 16.0/16.0 0.500 21.4 8 x 1/2" x 16.5 I"/ 16.0/1 6.0 0.135 240.0 8 x 1 /2" x 207.2 iRT 1BOLTS 16.0/ 16.0 10.135 173.7 8 x 1 /2" x 228.0 A307 EC-101 W12X22 A SECOND FLANGE FLANGE BRACE SEE FRAME CRDSS BRACE IS REQUIRED' i 1 5/8' IF '(2)' IS NOTED IN THE FLANGE BRACE TABLE. R.F. .COLUMN/RAFTER SEE FRAME CROSS SECTION FOR LOCATIONS, 6 BOLTS TOTAL ADDITIONAL HOLES ARE PRESENT FOR ALIGNMENT PURPOSES ONLY 8' 0" 8'-0" 6' 6" 1' -0 4'-0 4'-0 - JOIST SPACING 10 1/ 4' 7 ® 4'-10 3 8" PURLIN SPACING - a RF1 102 Ia GENERAL PLASTICS a STRUCTURAL INSULATION I I FOAM BLOCK. (BY OTHE S) O •- Q WU O UI iD rnU io Z O i I I I5 If MU R T 6., W x U 1)0 R T 6" 1'-2 11 16" 18'-1 3 16" 18'-0 3 8" V-5 1 8" CLEARANCE CLEARANCE - 19'-5 1/2" 19'-5 1/2" D 38'-11" OUT -TO -OUT OF STEEL I i O U MAIN FRAME ELEVATION: FRAME LINE 1 REVISI NS RFV. I DESCRIPTIONS - DATE D nside Flange v x Thk x Length 6 x 3 8 x 228.0 6 x 3/8' x 176.7 8 x 5/8" x 185.7 8 x 1 /2" x 228.0 WALTER E. WOOD P.E. FLORIDA P.E.# 61323 SOO PARKWAY ADELEL, GA GA 31620 pl\ppltr IrilUr No.613 BLDG#2 BLDG#1 STATE OF ;• KEY PLAN r rrrrrninttttlHIP tftt ORIGINAL SIGNATURE REQUIRED DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION E I FINAL ERECTION PROJECT THE FATHER'S TABLE RIGID FRAME ELEVATION EX] FOR CONSTRUCTION ID 24934-2 DESIGN, VLB . I DRAFTY KD CHECK- BCP E ] FOR APPROVAL E I OTHER, EXPLAIN PROJECT SANFORD, FL 32771 DATE- 08/29/17 SHEET 4 ADDRESS i i t. SPLICE BOLT TABLE Qty Mark Top Bot Int Type Dia Length SP-1 4 4 0 A325T 0.750 2.50 SP-2 4 4 0 A325T 0.875 3.50 FLANGE BRACE TABLE FRAME LINE 4 0ID SIDES MARK LENGTH OFFSET 1 1 FB41A 3'-5" 2'-8" 2 1 FB37.5A 3'-1 1/2" 2'-8" GENERAL NOTES: NOTICE TO ERECTOR A)lt is IMPORTANT that for members exceeding 30 ft. in length that a spreader bar be used when lifting. B)ALL flange braces and wind bracing must be installed prior to exterior finishes being applied. TYP. FLANGE BRACE / GIRT CONNECTION OFFSET 1/2'xl 1/4' 2-8' A307 BDLTSTYP, U.N.) U.N.) o o O I I o PURLIN/ GIRT \ 1/2'xl 1/4' A307 BOLTS A SECOND FLANGE FLANGE BRACE BRACE IS REQUIRED SEE FRAME CROSS IF '(2)' IS NOTED IN THE FLANGE BRACE TABLE. R.F. COLUMN/RAFTER SEE FRAME CROSS SECTION 6 BOLTS TOTAL FOR LOCATIONS, ADDITIONAL HOLES ARE PRESENT FOR ALIGNMENT PURPOSES ONLY 6'-6„ 1'-0. 4'04 0 JOIST SPACING I PURLIN SPACING 7 0 4'-10 3 8" cD I a N I UILRF2 102 n N GENERAL PLASTICS II STRUCTURAL INSULATION FOAM. BLOCK. (BY OTHERS) U I o z IL n R T 6„ W Z I tJ J Uo o U R 6„ 1 1'- 2 11 -16" - 36'-1 9 16" 1'-5 1/8" CLEARANCE 38'- 11" OUT -TO -OUT OF STEEL a A C MAIN FRAME ELEVATION: FRAME LINE 4 REVISIONS REV. DESCRIPTION- DATE D MEMBER TABLE Web Depth Web Plate Outside Flange Inside Flange Mark W x Thk x Len th W x Thk x Length StartEndThickLengthRF2- 1 01 1 4.0 1 4.0 0.135 164.7 6 x 5/16" x 228.0 6 x 3 8 x 228.0 14. 0/14.0 0.135 240.0 6 x 5/16" x 197.5 6 x 3/8" x 176.7 14. 0/14.0 0.250 21.0 6 x 5/16" x 15.9 RF2- 102 W18X35 RF2- 103 1 6.0/ 1 6.0 0.375 21.4 8 x 1 /2" x 16.5 8 x 5/8" x 185.7 1 6.0/1 6.0 0.135 240.0 8 x 1 /2" x 207.2 8 x 1 /2" x_ 228.0 1 6.0 1 6.0 O. T 35 1 73.7 8 x 1 2" x 228.0 V WALTER E. WOOD P.E. FLORIDA P.E.# 61323 d 500 VULCAN PARKWAY ADEL, GA 31620 AGE No. 61323 BLDG# 2 BLDG#1 ATE Q i Al IoNk KEY PLAN Z iNi i1p µRta ORI INAL SIGNATURE REQUIRED DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION R APP C I FINAL ERECTION PROJECT .THE FATHER'S TABLE RIGID FRAME ELEVATION CXI FOR CONSTRUCTION ID 24934-2 DESIGN VLB I DRAFT KD I CHECK BCP C I FOR APPROVAL PROJECT DATE, 08/29/17 SHEET 5 C ] EITHER, EXPLADDRESS AIN SANFRD, FL 32771 I SPLICE BOLT TABLE Qty Mark Top Bot Int Type Dia Length SP-1 4 4 0 A325T 1.000 3.50 FLANGE BRACE TABLE FRAME LINE 2 3 D ID SIDES MARK LENGTH OFFSET 1 2 FB39A 3'-3" 2'-8" 2 1 FB41A 3'-5" 2'-8" 3 2 FB41A 3'-5" 2'-8" 4 2 FB38.5A 3'-2 1/2" 2'-8" GENERAL NOTES: NOTICE TO ERECTOR A)It is IMPORTANT that for members exceeding 30 ft. in length that a spreader bar be used when lifting. B)ALL flange braces and wind bracing must be installed prior to exterior finishes being applied. TYP, FLANGE BRACE GIRT C NNECTI N OFFSET ( 2 B' 1/2'xl 1/4' TYP. U.N.)(TYP. A307 BOLTS U,NJ O I I o o oI PURLIN/ GIRT 1/2'xl 1/4' A307 BOLTS o A SECOND FLANGE 0 FLANGE BRACE SEE FRAME CROSS BRACE IS REQUIRED ONLY IF '(2)' IS NOTED IN THE FLANGE BRACE TABLE, R.F. COLUMN/RAFTER SEE FRAME CROSS SECTION 16 BOLTS TOTALFORLOCATIONS. ADDITIONAL HOLES ARE. PRESENT FOR ALIGNMENT PURPOSES ONLY Q 1 /4 12 3"-10 1/4' E 0 1 5/ 6•-6" 1"-0"" 4'-0" 4'-0"" - - JOIST SPACING 4"-10 1/ " 7 0 4'-10 3 8" PURLIN SPACING 1 I N a 2 2 2 3 _ RF3 102 d GENERAL PLASTICS IILIn STRUCTURAL INSULATION FOAM BLOCK. (BY OTHE S) i0 O w I n R pp U NZ z rl U W M R 1 1'-7 7 81' 35'-5 5 8" 1 "-7 7 8" CLEARANCE 38"-11" OUT -TO -OUT OF STEEL A C MAIN FRAME ELEVATION: FRAME LINE 2 3 REVISI NS RREV. I DESCRIPTD7N MEMBER TABLE Web De th Web Plate Outside Flange Inside Flange Mark W x Thk x Length W x Thk x LengthStartEndThickLength RF3-101 1 9.019.0 0.135 164.6 8 x 3/8" x 228.0 8 x 1 2 x 228.0 19. 0/19.0 0.135 240.0 8 x 3/8" x 197.3 8 x 1/2" x 176.6 19. 0/19.0 0.500 21.2 8 x 1/2" x 21.0 RF3- 102 W18X46 RF3- 103 19.0/19.0 0.500 21.6 10 x 3/8" x 19.4 10 x 1/2" x 185.4 19. 0/19.0 0.188 240.0 10 x 3/8" x 207.0 10 x 1/2" x. 228.0 19. 0/19.0 0.188 173.4 10 x 3/8" x 228.0 WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 111111p11111111/ fill f11/IV//, RE. P\'• , G E NStc , 0 0. 61323 a • qTATE OF BLDG#2 BLDG#1 o''•` AlCaR1dP' ffflifffffKEY PLAN ORIGINAL SIGNATURE REQUIRED DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUC TLR DATE CHKR APPD E ] FINAL ERECTION PROJECT THE FATHER'S TABLE RIGID FRAME ELEVATION EX] FOR CONSTRUCTION ID 24934-2 DESIGN-VLB I DRAFT KD I CHECK- I FOR APPROVAL PROJECT DATE+OB/29/17 SHEET 6 E I OTHER, EXPLAIN ADDRESS SANFORD, FL 32771 ERECTOR NOTE: THIS BUILDING HAS SPECIFIC ROOF AND/OR WALL FASTENER 11/2 REQUIREMENTS. PLEASE REVIEW THIS DETAIL PRIOR TO ERECTING u THE ROOF & WALL PANELS. FAILURE TO FOLLOW THESE SPECIFIC 1 /e 31/2' REQUIREMENTS COULD RESULT IN LOSS OF ROOF OR WALL PANEL(S). 21/2' 36' NOMINAL COVERAGE B DECK P-0' 1'-0• i 1'-1. ETAILA' 12-24 X 1-1/4 HVH S #5 V/V (IMPAX) PANEL FASTENER SPACING AT INTERMEDIATE SUPPORTS 6' 6' 6' I 6' 1 6' 1 6' 12-24 X i-1/4 HVH SD #5 V/V (IMPAX) PANEL FASTENER SPACING AT PANEL ENDS 14 STITCH FASTENERS' 20' /C DETAIL 'A' B DECK IER DETAIL F RTIAC LY ENCL VISIONS ROOF SLOPE 0' TO <3' WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 No.61323 = ci : i TATE OF %crif WALL FASTENER DETAIL PLAN KEY PLAN Z ejru{{{¢!!!!u00,1! ORIGINAL SIGNATURE REQUIRED DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTIDN C I FINAL ERECTION PROJECT THE FATHER'S TABLE EASTERNER DETAILS CXI FOR CONSTRUCTION ID 24934-2 DESIGN, VLB DRAFT, KD CHECK, BCP C I FOR APPROVAL PROJECT SANFORD, FL 32771 DATE>08/29/17 SHEET 7 C I OTHER, EXPLAIN ADDRESS 102 1 3/4" 1 3/4" r2"x 1 1/2" 25T BOLTS DETAIL "B" I MR-11 MB-12 _ BLDG#1 PS-12 PS-12 PS-12 PS-12 FBLDG#2TI BLDG#1 03 - - - - - - - - - - - - - - - - -3- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I - - - C RF1-1RF-103 RF3-103 RF2-103 KEY PLAN D JOISTS & BEAMS FRAMING PLAN WALTER E. WOOD P.E. FLORIDA P . E.61323 3/ 8" THICK PL 500 VULCAN PARKWAY 2) 3/4""x2 1/2" A325T BOLTS (TYP.) ADEL, GA 31620 1/ 2" CAP PLATE 3/8" THICK PL 1 4 2) 3/4"x2 1/2" W10x26 8" 1/4" 1/4" 1/4" 1/4" 8..````O.`{ pN 111" unCurprrrhrrrr0 A325TBOLTS (TYP.) W10x26 1/ 2"xl 1/2" 1/2"xl 1/2" ••R.• • E'• A325T BOLTS A325T BOLTS W10x45 W10x45 I I I I •• O N N o. 6132 6" WIDE x 12" x 1/2" THICK a = 3 =_ d PL. - BOLTS BY OTHERS I = i i/I D 6" HIDK PL.2,. x 1/2.. a •.: STATE OF 8" INSULATION BY OTHERS O 1. 5" "B" 10" PURLIN -' 'f OR. DP'•'\\k DECK PANEL RIGID RAFTER SECTION S1 5>NG 11((( 1tl1!1!!!!!lt GENERAL PLASTICS BOLTS BY OTHERS STRUCTURAL INSULATION RIGINAL SIGNATURE REQUIRED FOAM BLOCK. BY OTHERS GENERAL PLASTICS STRUCTURAL INSULATION DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION RIGID RAFTER FOAM BLOCK. (BY OTHERS) REVISIONS REV. DESCRIPTIDN, DATE DTLR DATE CHKR APPD E I FINAL ERECTION PROJECT ITHE FATHER'S TABLE 1 JOISTS & BEAMS FRAMING PLAN SECTION C SECTION D EXI FOR CONSTRUCTION ID 24934-2 DESIGN- VLB DRAFT; KD CHECK- BCP E I FOR APPROVAL PROJECT DATE;08/29/17 SHEET 9 E I OTHER, EXPLAIN ADDRESS SANFORD, FL 32771 1 4 79'-6" OUT -TO -OUT OF STEEL 2 3 26•-0" 27•-0" ROOF SHEETING PLAN PANELS: 22 C.. 1.5" "B" DECK - GALVANIZED m BLDG#2 BLDG#1 KEY PLAN r J7 WF-103 G-109 G-111 G-113 I n H G-10 G-110 G-112 n N t` I N t` n N I N O O 3 3 RF1' 103 RF3-103 - RF3-103 24'-3 13/16" CLEAR SIDEWALL FRAMING: FRAME LINE C Q i Q WALL PANEL BY OTHERS GENERAL NOTES: 1.) IF CABLE BRACING, WIND BENTS, WIND COLUMNS, OR WEAK AXIS DESIGN OF SIDE WALL COLUMNS WERE NOT PROVIDED IT HAS BEEN DETERMINED THAT DIAPHRAGM PANEL ACTION IS SUFFICIENT TO RESIST IN —PLANE WIND FORCES. TEMPORARY BRACING SHOULD BE PROVIDED BY ERECTOR UNTIL ALL WALL AND ROOF PANELS ARE INSTALLED. 2.) ADDITIONAL GIRTS MAY BE PRESENT IN THE END OR CORNER BAYS OF THIS WALL ELEVATION. THESE ARE REQUIRED TO SATISFY CODE —DEFINED CORNER ZONE WIND PRESSURES IN ORDER TO PROVIDE THE MOST ECONOMICAL BUILDING POSSIBLE, THESE GIRTS ARE NOT INCLUDED FOR THE FULL LENGTH OF THE WALL. NON —UNIFORM GIRT SPACING OR RESULTING APPEARANCE IS NOT A CAUSE FOR COMPLAINT OR REJECTION. OPEN TO REMAIN OPEN @ EXISTING SIDEWALL: FRAME LINE C REVISI N 24934-1 RF2-103 wr-ivi - vvr-iw 6 HJZJI J/`+ / WF-102 — WF-103 8 A325T 3/4; 2 1/2;; WF-101 — RF3-103 16 A325T 5/8 2 1/4 WF-in9 - RF.3-ln3 1 1R AW-,T 5/8" 2 1/4" WF—-6" ZF_i I 02 vv 1I VVVL0882- W JJ35' - V WF-103 W12X26 24'-3 13 16" E-101 1OE375D14 26'-5 1/'" E-102 1OE375D14 25'-11 1/2" E-103 t0E375D12 26'-11 1 2" G-108 8X25C14 25'-0 1 4" G-109 8X35Z12 25'-0 1/4" G-110 8X25C14 24'-3 1/2„ G-111 8X35Z12 24'-3 1/2„ G-112 8X25C14 25;-6 1/4 WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 24934-, 4 AEA.. 0.613'13 BLDG#2 BLDG#1 O• STATEOF :s. Q 0RIOP••'•' Az _ L c, S ONAL E '• KEY PLAN""rmsl, t;iuuNttlltttt FINAL SIGNATURE REQUIRED DRAWING STATUS C I FINAL ERECTION CXI FOR CONSTRUCTION E I FOR APPROVAL E I OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION DATE DTLR DATE CHKR APPD PROJECT THE FATHER'S TABLE SIDEWALL FRAMING ID 24934-2 DESIGN, VLB DRAFT, KD ICHECK BCP PROJECT ADDRESS SANFORD, FL 32771 DATE, 08/29/17 SHEET 11 3'-10 1/4" 4'-O" 4'-0" — — 4'-0" r 4'-0" I i 4'-0" 24934-1 4'-0" 4'-0" 79'-6"OUT-TO-OUT OF IIIIIII I RF2-101 Y I I I I I I I I I 24934-i I I I I GENERAL NOTES: 1.) IF CABLE BRACING, WIND BENTS, WIND COLUMNS, OR WEAK AXIS DESIGN OF SIDE WALL COLUMNS WERE NOT PROVIDED IT HAS BEEN DETERMINED THAT DIAPHRAGM PANEL ACTION IS SUFFICIENT TO RESIST IN —PLANE WIND FORCES. TEMPORARY BRACING SHOULD BE PROVIDED BY ERECTOR UNTIL ALL WALL AND ROOF PANELS ARE INSTALLED. 2.) ADDITIONAL GIRTS MAY BE PRESENT IN THE END OR CORNER BAYS OF THIS WALL ELEVATION. THESE ARE REQUIRED TO SATISFY CODE —DEFINED CORNER ZONE WIND PRESSURES IN ORDER TO PROVIDE THE MOST ECONOMICAL BUILDING POSSIBLE, THESE GIRTS ARE NOT INCLUDED FOR THE FULL LENGTH OF THE WALL. NON —UNIFORM GIRT SPACING OR RESULTING APPEARANCE IS NOT A CAUSE FOR COMPLAINT OR REJECTION. I.. I RF3-101 RF3-101 24'-3 13/16" 1 CLEAR SIDEWALL FRAMING: FRAME LINE A Q i Y WALL PANEL BY OTHERS SIDEWALL: FRAME LINE A REVISI NS REV. DESCRIPTION, Wi -IU'+ — V— 11 O HLJTWF-105 — W8A325 WF- 104 — R16 A325T 5/8'4r " 22 4 wp'-1n5 - R16 A325T 5/8" 2 1/4 2- VVr— I VJ WF-104 VV 1 GALO W10882 4Y —. 34'- 8 1 4" WF-105 W10882 34'-8 1/4" E-104 10E375D12 26'-11 1/2" E-105 1OE375D14 25'-11 1 2' E-106 10E375D14 26'-5 1 2" G-114 8X35Z12 25'-7 1/4" G-115 8X35Z13 25'-7 1/4 G-116 8X25Z12 24'-3 1/2„ G-117 8X35Z13 24'-3 1/2 G-118 BX25Z12 25'-1 1/4, f1-11 q RY S71 i 05'-1 1 /4" BLDG#2 BLDG# 1 KEY PLAN DRAWING STATUS VULCAN STEEL STRUCTURES, INC E I FINAL ERECTION PROJECT THE FATHER'S TABLE EX] FOR CONSTRUCTION ID 24934-2 E I FOR APPROVAL PROJECT SANFORD, FL 32771 E I OTHER, EXPLAIN ADDRESS WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 DER E• LJ, ., v GENs •pO NoNo.61323 9a peg 1: sT,ar or : AIVAJN t1l lit Ii11aH! UIHF't4.. ORI NAL SIGNATURE REQUIRED IRONROCK COMMERCIAL CONSTRUCTION SIDEWALL FRAMING DESIGN- VLB I DRAFT, KD CHECK- BCP DATE,08/29/ 1 ISHEET 12 1-OUT- Im m I I INN V)1 I I IN 12 ` al I Q I Ia_ — II RF1 102 L_ II G-, 02 III G-, 05 III I III GENERAL PLASTICS STRUCTURAL INSULATION ) IIIIIIIIIIII FOAM BLOCK. (BY OTHERS) II II IIII c-102 I c—tas II III II II II III p II III II III II II II , G-104G-102 41 I it III Ilo -III Oil IIIIIIiIII II IIWIIII III IIIIIIG-102 I It 1 G-104 III II III II II III II II II III II II I1 G-101 G-103 1wh II II III II III II III II II II III II II II II III II II jll II BA E3 ..--I II II EC-107 ENDWALL FRAMING: FRAME LINE 1 GENERAL NOTES: 1.) IF CABLE BRACING FOR END WALL IS NOT SHOWN ON ERECTION DRAWINGS IT HAS BEEN DETERMINED THAT DIAPHRAGM PANEL ACTION OR QUARTER —PANEL BRACING IS SUFFICIENT TO RESIST IN —PLANE WIND FORCES. TEMPORARY BRACING SHOULD BE PROVIDED BY ERECTOR UNTIL ALL WALL AND ROOF PANELS ARE INSTALLED. 2.) ADDITIONAL GIRTS MAY BE PRESENT IN THE END OR CORNER BAYS OF THIS WALL ELEVATION. THESE ARE REQUIRED TO SATISFY CODE —DEFINED CORNER ZONE WIND PRESSURES IN ORDER TO PROVIDE THE MOST ECONOMICAL BUILDING POSSIBLE, THESE GIRTS ARE NOT INCLUDED FOR THE FULL LENGTH OF THE WALL. NON —UNIFORM GIRT SPACING OR RESULTING APPEARANCE IS NOT A CAUSE FOR COMPLAINT OR REJECTION. 412 FLANGE BRACE TABLE FRAME LINE 1 V ID SIDES I MARK LENGTH OFFSET 1 . 1 1 FB38F 3'-2" 2'-8" ENDWALL: FRAME LINE 1 BLDG#2 BLDG#1 vzm KEY PLAN DRAWING STATUS rPROJECT AN STEEL STRUCTURES, INC I 1 FINAL ERECTION THE FATHER'S TABLE EX] FOR CONSTRUCTION 24934-2 1 7 FOR APPROVAL ECTEI THER, EXPLAIN SANFDRD, FL 32771 ESS Cl.- I U I YY LALL JY -J '/ I V G-101 8X25Z13 17'-9 3/16;; G-102 8X25Z14 17'-9 3/16 G-103 8X25Z13 17'-8 1/2„ G-104 8X25Z14 17'-8 1/2 WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL GA 31620 111p111t1111ul 7pN'gq„ R E. • fie,°•\GENSF'.0 No.61323 o '• STATE OF ORfpP•'ti' r ORIG NAL SIGNATURE REQUIRED IRONROCK COMMERCIAL CONSTRUCTION DESIGN, VLB I DRAFT] KD I CHECKS BCP DATE-08/29/17 SHEET 13 m m Ill _ _ Ill OF I I — — NI I I IN 1/4• 2 I 1/4• 2 I nRF102 c-106 cLlo7 II I WALL PANEL BY OTHERS I II ` " II II GENERAL PLASTICS I a I I STRUCTURAL INSULATION Il lli IIIIIFOAMBLOCK. (BY OTHERS) o Ir III G-106 G-107------ II o— — — — — — — I " II II A II III I II II II ` I II Ih to II III o I II II NII II I II Ilo II II W II " II II II II ii N I OPEN TO 24934-1 II II I I II II II III I II II II ` I II II II III I II II II I I I it II II_ I II I I — — — — — — — — "` I-- — — — — — — — — — — — — — — — — — — — — — — — — — — EC-102 ENDWALL FRAMING: FRAME LINE 4 ENDWALL: FRAME LINE 4 SEE SHEET NO.18 FOR SECTION A GENERAL NOTES: 1.) IF CABLE BRACING FOR END WALL IS NOT SHOWN ON ERECTION DRAWINGS IT HAS BEEN DETERMINED THAT DIAPHRAGM PANEL ACTION OR QUARTER —PANEL BRACING IS SUFFICIENT TO RESIST IN —PLANE WIND FORCES. TEMPORARY BRACING SHOULD BE PROVIDED BY ERECTOR UNTIL ALL WALL AND ROOF PANELS ARE INSTALLED. 2.) ADDITIONAL GIRTS MAY BE PRESENT IN THE END OR CORNER BAYS OF THIS WALL ELEVATION. THESE ARE REQUIRED TO SATISFY CODE -DEFINED CORNER ZONE WIND PRESSURES IN ORDER TO PROVIDE THE MOST ECONOMICAL BUILDING POSSIBLE, THESE GIRTS ARE NOT INCLUDED FOR THE FULL LENGTH OF THE WALL. NON —UNIFORM GIRT SPACING OR RESULTING APPEARANCE IS NOT A CAUSE FOR COMPLAINT OR REJECTION. BLDG#2 BLDG#1 KEY PLAN REVISIONS DRAWING STATUS VULCAN STEEL STRUCTURES, INC REV. DESCRIPTION- DATE DTLR DATE CHKR APPD C I FINAL ERECTION PROJECT THE FATHER'S TABLE CXI FOR CONSTRUCTION ID 24934-2 C I FOR APPROVAL PROJECT C I OTHER, EXPLAIN ADDRESS SANFORD, FL 32771 EC-lUZ W1UX15 9 -lU 9/lb G-106 8X25Z14 17'-8 3/8' 3 WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 310/ tQ\\ 1111111tIRtttttt , j 11/ O cc'• . OO': No. 61323 ylr j / o STATE OF IN AI EN ORIGINAL SIGNATURE REQUIRED IRUNROCK COMMERCIAL CONSTRUCTION ENDWALL FRAMING DESIGNS VLB I DRAFT- KD CHECK- BCP DATE: 08/29/17 ISHEET 14 END OF BUILDING 1/4" 2'x4'xl6GA, RAKE ANGLE r21112 S, D. SCREW EACH ROOF MEMBER 2) 1/2'xl 1/4' A307 BOLT/NUT R F PURLIN PLATE WELDED TO RAFTER RAFTER FLANGE BRACE 1/2'x1 1/4' A307 BOLTS RIGID FRAME RAFTER A 10 ROOF PURLIN TO EXPANDABLE ENDWALL RIGID FRAME SEE ENDWALL FOR BOLT SIZES LLLB ENDWALL COLUMN RIGID FRAME RAFTER TO ENDWALL COLUMN WALL PANEL 12 x 1 1/4' SDS INSIDE CLOSURE W/ WASHER 6' O,C,) I BASE ANGLE 2' x4'x16GA. FINISHED FLOOR 1/ 4' x 1' NAIL - IN ANCHOR @ 36' O.C. (BY OTHERS) BASE ANGLE WITHOUT BASE TRIM WITHOUT SHEETING NOTCH WITH BASE CLOSURES BC112 1/ 2" X 1 1/4' A307 BOLT/NUT RIGID FRAME RAFTER ANGLE B19 116 TO ENDWALL COLUMN ENDWALL COLUMN WELDED ANGLE LINL W tiLL U11-, 1 J 0--- 0 WELDED PLATE - SIDEWALL GIRT BLDG#2 BLDG#1 RIGID FRAME COLUMN KEY PLAN O WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY O ADEL, GA 31620 taaattatlUtnuutlr° rOprr --. asss RE. Y.• GENSF •p0O ' ENDWALL -' GIRT ``:• No. 61323 C Ej ENDWALL COLUMN TO WALL GIRT D13)CORNER COLUMN TO WALL GIRT o . STATE OF :'2` P - k/ t! v a TIONAV a j t O; R[1 111AL SIGNATURE REQUIRED REVISIONS DRAWING STATUS C 3 FINAL ERECTION CXI FOR CONSTRUCTION E 3 FOR APPROVAL C 3 OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC IRONROCK COMMERCIAL CONSTRUCTION REV. DESCRIPTION DATE I DTLR I DATET CHKRT APPD PROJECT THE FATHER'S TABLE DETAIL DRAWINGS ID 24934-2 DESIGN, VLB DRAFT. KD CHECK BCP PROJECT ADDRESS SANFORD, FL 32771 DATE 08/29/17 SHEET 15 r ENDVALL COLUMN C.i 11 CU BASE PLATE PLAN ELEVATI ON D BASE PLATE FOR ENDWaLL COLUMN 2 1/2' 3 3/4' BUILDING COLUMN PER DESIGN WIND BENT or WIND COLUMN H9 WIND BENT OR WIND COLUMN TO BUILDING COLUMN PURLIN/GIRT A307 1/4' I A307 B LTS TYP. U.N,) o 0 Zo l 0 0 l o o o 0 1/2'xl 1/4' A307 BOLTS 0 0 A SECOND FLANGE FLANGE BRACE BRACE IS REQUIRED NLY SEE FRAME CROSS IF '(2)' IS NOTED IN THE RIGID FRAME FLANGE BRACE REFERENCE. RAFTER SEE FRAME CROSS SECTI N FOR L CATIONS. 6 BOLTS T TAL ADDITI NAL HOLES ARE PRESENT FOR ALIGNMENT PURPOSES ONLY r ROOF PURLIN TO u C RIGID FRAME rA\/r C`TMlJT CID FRAME LUMN L/ L Ai 1/ `t A307 FIN NECK BOLTS TYP,) J 1 EAVE STRUT TO RIGID FRAME REVISIONS FLANGE EXTENSI N FRAME COLUMN COLUMN FLANGE BRACE o I 0 o I Illy WALL GIRT 1/2' X 1 1/4' BOLT/NUT WELDED PLATE H 6 WALL GIRT TO FRAME COLUMN 1/4" ID FRAME UMN 1 A307 FIN NECK BOLTS TYPJ J 7 EAVE STRUT T RIGID FRAME FLANGE EXTENSI N 11KMW11VU JIH UJ VULCAN STEEL STRUCTURES, INC C ] FINAL ERECTION PROJECT THE FATHER'S TABLE IX] FOR CONSTRUCTION ID 24934-2 C ] C ] FOR APPROVAL OTHER, EXPLAIN PROJECT ADDRESS SANFORD, FL 32771 BLDG#2 BLDG#1 KEY PLAN WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCAN PARKWAY ADEL, GA 31620 E No.6132 fTeATE OF : 2 OR I'D NA ORI INAL SIGNATURE REQUIRED IRONROCK COMMERCIAL C NSTRUCTION DETAIL DRAWINGS DESIGN- VLB I DRAFT- KD I CHECK- BCP DATE,08/29/17 ISHEET 16 RUT END OF BUILDING 1/4 # 12 S, D, SCREW I2'x4'xl66A, RAKE ANGLE II 1/2-xl 1/4- FIN NECK II BOLTS CTYPJ II II II I I SECTION ELEVATI N J23 EAVE STRUT TO RIGID FRAME CABLE FL-L C GRIP COLUMN OR RAFTER WEB HILLSIDE WASHER NUT EYEB LT END OF BUILDING 1/4' #12 S. D, SCREW 2'x4'xl6GA, SLOT IN WEB TO INSEF RAKE,ANGLE HILLSIDE .WASHER AND EYEBOLT J NUT EAVE STRUT EYEBOLT FLAT WASHER II 1/2'xl 1/4' FIN NECK I BOLTS CTYPJ CABLE ILLSIDE WASHER I II COLUMN OR RAFTER WEB FLO-LOC GRIP SECTION ELEVATI N J25 EAVE STRUT TO RIGID FRAME Q1 DIAG NAL CABLE, EYEBOLT END SIDEWALL COLUMN BLDG#2 BLDG#1 ANCHOR BOLTS C LUMN KEY PLAN WALTER E. WOOD P.E.- FLORIDA P.E.# 61323 Q I % 500 VULCAN PARKWAY SLOT IN INSERT WASHER & WEB T HILLSIDE EYEB LT WASHER ANCHOR I I O ADEL, 31s2o nwRi ,n„nnn,v. E, O BOLTS PO••v GENSFQ'; BASE PLATE FRAME LINE BASE PLATE = No.6132 PLAN ELEVATI N ATE OF O-LE B LT END LE R 2 ANCHOR BOLTS AT SIDEWALL- COLUMN S 2 INTERI R COLUMN ANCHOR BOLTS oo:oR,oP: <oR,oP:w` Q.'' J err / h' y ,,{{pp,,77 ORIGINA SIGNATURE REQUIRED REVISIONS DRAWING STATUS VULCAN STEEL STRUCTURES, INC IRONR CK COMMERCIAL CONSTRUCTION REV. DESCRIPTIDN, DATE DTLR DATE CHKR APPD E I FINAL ERECTION PROJECT THE FATHER'S TABLE DETAIL DRAWINGS EXI FOR CONSTRUCTION ID 24934-2 DESIGN- VLB DRAFT, KD CHECK, BCP E I FOR APPROVAL PROJECT DATE 08/29/17 SHEET 17 E I OTHER, EXPLAIN SANFORD, FL 32771 ADDRESS ERECTOR NOTE: C NNECTI N WILL VARY FROM THIS DETAIL DUE TO DESIGN LOADS AND BUILDING SIZE, REFERENCE CROSS SECTI N DRAWING FOR ACTUAL C NNECTI N TYPES, BOLTED— O O END PLATE O O :::]-- TOP BOLTS, SEE TOP FLANGE"'DRAWING FOR SIZE. O O INTERMEDIATE BOLTS, WEB THE NUMBER OF TOP OR BOTTOM BOLTS GREATER THAN FOUR, jo O BOTTOM BOTTOM BOLTS, SEE FLANGE O O DRAWING FOR SIZE, oBOLTS FOR RAFTER TO COLUMN C NNECTI N 8" 8" Luj nw O 1 548" RAKE ANGLE 2x4x16GA.) 1 2x 1 1 /4" SDS W/WASHER o (1 PER PURLIN) T 0 N 0 O CDI w rW=8 X I Of RIGID rnnnnr R Jrn c-rrrrrnirnc ERI R UMN DINTERI R COLUMN TO RAFTER LOW ROOF PURLIN NEAREST STUB L STD. FLANGE BRACE oLIQa N 5"x1/2" END PL 4) 5/8"x2 1 /4„ SECTION AA325TBOLTS DESCRI I1KH W 11VU a H i w - VULCAN STEEL STRUCTURES, INC C I FINAL ERECTION PROJECT THE FATHER'S TABLE CXI FOR CONSTRUCTION ID 24934-2 I I C I FOR APPROVAL OTHER, EXPLAIN PROJECT ADDRESS SANFORD, FL 32771 BLDG#2 BLDG#1 KEY PLAN WALTER E. WOOD P.E. FLORIDA P.E.# 61323 500 VULCIAANN RKWAY ER .... 0-, o. 6132 o : STATE OF OR 10 ORIGINAL SIGNATURE REQUIRED IRONROCK COMMERCIAL CONSTRUCTION DETAIL DRAWINGS DESIGN- VLB DRAFT, KD CHECK, BCP DATE:08/29/1 ISHEET 18