HomeMy WebLinkAbout150 Specialty Pt 18-2986 Plans Int. remodelPARCEL I.D. # 28-19-30-516-0000-0110 8 0120 OWNER/DEVELOPER: ROBES, LLC PAUL SEBOR 751 CRICKLEWOOD TERRACE LAKE MARY, FLORIDA 32746 TELEPHONE: (407) 416-0369 E-MAIL: paul@seborgroup.com ENGINEER: CASTILLO ENGINEERING SERVICES 2381 CREST RIDGE COURT SANFORD, FLORIDA 32771 TELEPHONE: (407) 474-9181 FAX: (407) 328-5397 E-MAIL: rick@rcengineering.cc CONTACT: RICK CASTILLO, P.E. PROJECT MANAGER: JHR CONSULTANTS, INC. 312 FOREST AVE ALTAMONTE SPRINGS, FL 32701 TELEPHONE:(407) 262-9176 FAX: (407) 262-9170 E-MAIL: jackreynolds@embargmail.com CONTACT: JACK REYNOLDS CONTRACTOR: WOOD KNOT CONSTRUCTION CO. 1191 STANLEY STREET LONGWOOD, FL 32750 TELEPHONE: (407) 830-9912 FAX: (407) 831-6981 E-MAIL: greg.edebohls@gmail.com CONTACT: GREG EDEBOHLS LTil 1 :1 --A A&I mW VMAK N Icilm RAZILMWA �11+y:1W:\LOCATION :l•1:1� .. APPLICABLE CODES im 901 In LID] :9- 150 SPECIALTY POINT SANFORD, FLORIDA 32771 Df4*WY K:- UALTY PC 0-'Right-of-We (Aaphdt Road) —� A ��'r"w _ 3*1-�1 f qF 5 SOEMNIC \ �4'56' W 149.ar 1r1 - � 1 Raaea 1R o a un.y EaSemenl N ! �G SUITE 234 SUITE 222 SUITE 210 SUITE 198 SUITE 186 SUITE 174 SUITE 162 SUITE 150 Z 1 1COVERM 5 SIDEWALK COVERED 57 SIDEWALK illlll: & c�i►►ul 1 sm f. 1 1 1 . 17MTi 5 GONC. SIDEWALK. - - - • • . '.. 10 oraina8e a U.ty Easement S 0.14'S8• E 200.00' (P) S 0.14'59' E 219.50' (P) Z - 2017 6th ed. FLORIDA BUILDING CODE (BUILDING) - 2017 6th ed. FLORIDA BUILDING CODE (PLUMBING) - 2017 6th ed. FLORIDA BUILDING CODE (MECHANICAL) - 2017 6th ed. FLORIDA BUILDING CODE (ACCESSIBILITY) - 2017 6th ed. FLORIDA BUILDING CODE (ENERGY CONSERVATION) - 2017 6th ed. FLORIDA FIRE PREVENTION CODE - 2014 NATIONAL ELECTRICAL CODE - ALL APPLICABLE STATE, FEDERAL AND LOCAL CODES & ORDINANCES WILL APPLY UPSALA ROAD ARCHITECTURAL_ SITE PLAN DESIGN CRITERA CONSTRUCTION TYPE: TYPE II B, UNPROTECTED, FIRE SPRINKLED SINGLE STORY BUILDING NON COMBUSTIBLE BUILDING HEIGHT: 22' FRONT EAVE HEIGHT, 17'-6"REAR EAVE HEIGHT MIXED OCCUPANCY CLASS: BUSINESS (B) AND STORAGE (S-2) MULTI TENANT BUILDING OCCUPANT LOAD CALCS FOR ENTIRE BUILDING BUSINESS: 9,453 SF/l00 = 95 PEOPLE WAREHOUSE: 500 GROSS S.F./ PERSON 12,867/500 = 26 PEOPLE OCCUPANCY LOAD =121 PEOPLE G►e s��fe sl a !� �a it ll s74� Q.c� INDEX OF DRAWINGS BUILDING PLANS _- CS 1 COVER SHEET A-1 2 FLOOR & LIFE SAFETY PLAN (UNITS 174 & 210) MECH 3 ELECTRIC AND PLUMBING PLAN (UNITS 174 & 210) HVAC 4 HVAC PLAN (UNITS 174 & 210) ELEC 5 PANEL SCHEDULES AND RISER DIAGRAM SANFORD FIRE DEPARTMENT THESE PLANS ARE REVIEWED AND CONDITIONALLY ACCEPTED FOR JUL — 2018 PERMIT. AN ISSUED PERMIT SHALL BE n DEEMED PERMISSION TO PROCEED WITH WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET ASIDE ANY OF THESE PROVISIONS OF THE TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT THEREVIEWED BY: FIRE PREVENTION DIVISION FROWATT MINNETTO THEREAFTER REQUIRING A CORRECTION OF ERRORS ON THE PLANS, CONSTRUCTION OR OTHERS-ANFORD FIRED PT. VIOLATIONS OF THE CODE. DATE: �� o� NOTES TO CONTRACTOR: • THIS IS A BUILDER'S SET OF DRAWINGS PREPARED TO A LEVEL OF COMPLETION SATISFACTORY FOR BUILDING PERMIT PURPOSES AND CODE COMPLIANCE. THESE PLANS ARE ADEQUATE FOR CONSTRUCTION BY A LICENSED KNOWLEDGEABLE AND EXPERIENCED CONTRACTOR FAMILIAR WITH THIS TYPE OF CONSTRUCTION AND THE 2017 FLORIDA BUILDING CODE, 6TH EDITION. • THE GENERAL CONTRACTOR AND HIS SUB CONTRACTORS SHALL CAREFULLY STUDY AND COMPARE CONSTRUCTION DOCUMENTS FURNISHED BY THE ENGINEER AND THE OWNER PRIOR TO START OF CONSTRUCTION. ANY ERRORS, INCONSISTENCIES OR OMISSIONS DISCOVERED DURING PLAN REVIEW OR CONSTRUCTION SHALL BE REPORTED TO THE DESIGN PROFESSIONAL IMMEDIATELY. ANY FAILURE TO REPORT SUCH DISCOVERIES SHALL BE THE CONTRACTOR'S LIABILITY. CITY STAMPS v p'.s liii y�rtir� BUILDING DING )._)IV'QIOi\I OFFICE PERMIT #_ lif- c,25q� CAST/�����s�i 4 No 2590 S TAT E F •• 111 JUL 0 3 2018 ERMOCRATES E. CASTILLO, P.E. DATE FL. REG. # 52590 co z W 0 U COME 111111 ollecom W U r 0 ti = F— M F— W Z �O Quo Q ��0 W U�LL > 0 -Q LL� LL U w 0 U 00-0 Woo 0 z m Q W Cn Cn C' ca N p- U E _z v) o a� � Z N o� z W E ti cV 0 Q > a o r- H Q !A d. Ncfl A CD �ww�Y W Z Z O IT z Ov O = •a Q u- • • �' _ --i W -� ch Q F— u- W DATE: SCALE: 5/20/18 NTS DRAWN: JHR APPROVED: RC SHEET NAME: cs SHEET: 1 OF 5 J� CL Design No. U=105 \onbearing Wall Rating-- I HR. r2) C3 r ; L i. Floor and Ceiling Runners - nn I , Nc:i hmrel <h•r. •, n nu - :'ti in tide imm), 1-1 l in i ;, , , lion mr• (min \, 70 %ISG tchcn Item =( i u ,L •. .,t,l, attach,•.t to ti,4 r and ceilin�; n'itit Lr+tellers ;,•i,, i ' l i _. Steel Studs— C h.nnicl hal•,•1, - m - nu;rt ! 1 -1, to. balk retu ut,..,,rn;-d r r, I'll.: 1`(i tchrn thin dt- t, u.ed; ..; d, :ec,• pa„•,'. '_. it,- 0( Batts anti I3tankets' — It)ption,111 \Ito,!,i er, a,i "I ;;la— !1'. Not, pal nalh' or completeit. tilling .tud r.r.;i`: SmBall- and HlankeL,(IVIZ),.,i r i,un r„A (J.I if!ea,tul .[tir-. ,A, Fillet, Sprayed' — :A, an alte!ntl I+al[ n,i Bunk t Lan, ~prat a pplir,i ,rlluktx m,uiau„I m,trri.0 hb,'r 14 AT} !i<d Wilk ,cairr it, ,intirleieh fill tht- rnrl,.t'I'd , IN u•.:,...c.,rd.m r ,th :it. I I,lu G„n ma ildlon, -lipplit"i ,„i i t \ i dr. ic•i ,;I ,t ;it I1, 5 GRL[\FIt3flt L 1_ C -c ... a: ;,!v,•<3,,, ,, ;r:>,:,.: !run GI win Huard`-- =.<i in. :':u.I-. -'. it :, r<i, ,it L,ehr,l t, ,A.i H:J+.sod l!ittir and Celliny; track a ith i ui. tong, I, p, tc,! ,crui, - ,im ,i + in OC. d, n• rules (it botr o and 12 in. (tt: i, 0), iieid of it .rtanl. Lich mite t4d to ti ally and [t },'n•,I n rti,Iv,+r[ dc, Ot tare t\h -n ,t ached t,i item o iresiti,-;,t ,immic.i ti .\ ilurritac :harmd,;. „allia,at<i c.irCtr,111,161t'd i„ n:rrlrn.; .110WI, i::cith i III i,at icp,. =tacl ,cn•t., ,I,accd i' in. I It _ AMERICVN GYPSLM CO i;ik•,:„.:.:ACi:C-C. B3;IiiNG NEW BLALDI`NC. MAI FRI3l S CO 13141 A\t RICA INC Bi,13 CEL01Fx- "Ir}u 1 C aNADIAN GYPSUM COMPANY , A', t_ !i.t CONTINENTAL GYPS U:\1 C,ONIPA\` --Iv t <:-t (t + l;t,;,,cGv ,,AC 1c C. G-i' G1PSUnI CORP, SUB OF CaORGiiA-PACIFIC (:t)RP-I,1„, iAAIFS HARDiL GYPSUM (NC - 1 \!A\ ••C" ,r I'It r. I'ARCF NORTH A\IP.RiC A INC - I_Cdi +. I ,I<( ICI-ChA I (;I. _-t. Iti(4 LION \L C YP$l 41 Cn l !,,+ 3 ,. ,: i St i "41 { ORC H S -IS-- \tlia-IVI_ `NA III IWO GYPSUM, IN OF P IFIC COAST BUILDiNG PRODUCTS INC—I,I Fil 5 lei GYPSUM INDUSTRY CO I TI i,pe' v S \\DARD GYPSUNI 1 1. C kri, a I i MPl i INLAND FORrs'r P!t( 11C t i ti CORPira, UNITFD STATES C YI"SU,3 CO — lPlr, \R. C. tl,\ I1' .\i l -\ 11 I .\R. SC \ �l IV 1\ l,( .•r U56 iFhICO S A DF C V ic),c IP( `... ,1 LSTR NC i , . r , ; , OCI ,f Gypsum Board t:\ tltlri it, t t em ; u Ihs k 4.1n camel, „qh lc,ehd .quo;, or Lr,<u•, _ - atpil I il'rit ntalh \, t u!om ,e tr , „r IIJ ,ta u I qt "X"M 01,,nl n r +icii l 411,k. I S I i r.t taut d no!ur, butt r ittl_ ,n uppu ire i i i 111 id 1 ,ta <.ui .•r t i. tt , l,-d pt 4ccl Ytad , alnd li'lor nt :It 1 In I'm!: I, } e <uei r ,, c d>+ut 0( ,it appk,d , .,`ntalh vi rX r$nt r.ic, t told b„tt rat d', � , d i r;. , i r t the field :, h, n2rt• r, q'I!i d ,crticalh. C:\�i•\MAN GYPSUM ,:( \IPA`•:, <- R,k il' \L. UN1rrt D STATESP l\I c Viv C, I F\-C:. li'-\it. P-\� 11C-,U: USG \iFCICC) 5 a , -\ PC - \It G�Psunt 13naId ..1- ;; # r,i thick. -I it „i,i n t..lh: .. d. .-d , : !:.•, ,ih n..i,•n,lii incrca,r,l l,: t-1 : -': i[r. C JI AN (:)'i SUlI CC3UP\Nl UNITED SiAI"L'SGYPSUM O ir} J: 1:" V., l USG MEXICO 1,A DF C V e> :UV ill AR. 4C . Gypsum Board 0- ua , r� rn•r _ r it, In I I ant r : 5 in ,. Thick I, } u, I ntI r h. ,i L: i.t s-D t„ ,h•, yrsc�' !�t I,r...,th...i± .r,.:,n.: :h• ,..:>- n.:,:'nr.J,:' LNI1'IDSD1rF';C,,7'SC\t joint rape and Coutpoiatd \ , + i , u . ,i "NIapplivd in ctni,eal e' m rr laatr n,ni .dI I..­ 'ti ,. coma n a ? t. u k: 1 r I t, r{, etllli .rr.a•, � o. Resilient Charnel -- ir},t, i .i- r, , \l i tY+iir IlI I homi t. I; ,', -I TTI 11 tIj.IN ,t.•al I, IV t I, ith . Steel Pratuim; :\lembors lNol tihm,io' — n ,it,:!;.::• + fwm lurrin n!n,...,nd rc, la_nt _�,,ta: i-.a>„ r,-.,..•r. Purring Chan u,els -- i.,r.u,.' al A bide ht - na. dr,•r,-}'a:r,i _1 , ; ,t ,�,,;:•; r.:Icctal i, iu,i-\s, ha: na1 seem,'d t ,tud.. ,!escribedr„ itcnt 1•- b. Stecl Framing Member.,,::nr :L.:nor1,,IWill .a n Iaud< iL', n, !. C li} . ,a„• P ;' K -. ti r ,r. rr or I, u PAC INfFRN. \I It1 t"i; -' 13adrity; Iac li ': ia-+il„.:!:n"i ALai}- 1 FIRE WALL U 46 5 21'-6" METAL ROOF DECK PURLINS "X" BD. TO EXTEND PASS PURLINS TO ROOF DECK SEAL SEAMS W/3M FIRE RATED CAULK 3-5/8" 20ga. "C" CHANNEL ATTACH TO PURLINS W/#8, SELF TAPPER SCREWS ONE HOUR FIRE WALL UL DESIGN #U465 5/8" "X" BD. BOTH SIDES 3-5/8", 20go. MTL. STUDS 16" O/C 18'-6" - 21'-O" R-13 INSULATION- 0 CONDITIONED SPACE ONLY 20ga. "C" CHANNEL ATTACH TO SLAB W/1" PINS, 32" O/C EXIST. 5" THK. SLAB BFIRE WALL SECTION #U465 12 1 /2 METAL ROOF DECK W/PURLINS - q i R-30 INSULATION AGAINST If I METAL ROOF PANELS 1 Ij I I Ijw to Ij I I ATTACH "C" CHANNEL TOP j PLATE TO PURLINS W/ II I I #8 SELF TAPPING SCRREWS II I 1 1 II I II I q I 1 I if I WIRES ATTACHED TO ROOF PURLINS q I TO SUPPORT TILE CEILING GRID h I Ij I i I 1 1 /2" DRYWALL j TO ROOF DECK p I I I THIS SIDE ONLY h ~—R-10 INSULATION AGAINST I I If METAL WALLY PANELS I R-13i INSULATION 11 LINTEL COURSE W/(1) i I Y I#5 CONT.1 1 -,-,�t"f H=I CEILING ON GRID ACOUSHUAL E 1I�II, Fk =H II II ► " F, I 8-8 11 Ir -;H o +#1' 11 11 PROP. NON BEARING 25ga. MTL. PROP. 3-5/8" 20 GA. „ 3-5/8" MTL. STUDS. 16O/C O ► " =H 4 11 STUD WALL 16" O/C 20 GA. W/ 1 /2" DRYWALL 0 11 W/ 1 /2" DRYWALL ► 10 -0 " 3: of 0 H = L 91-6m I Q 0 z 3: 0 Irk -H r 111 lj R-13 IN WALLS R-13 IN WALLS a i f 1j w-H H "C" CHANNEL BOTTOM PLATE O F_ II 11 I #1: ATTACH TO SLAB W/1" PINS. 32" O/C (TYP) o o m CD 11 If L---------------- 5 ---- SLAB TYPICAL INTERIOR �E�XERIOR WALL SECTION / O / of ��-------1— — — — — — — — — — — — -----� -- --- ® —------------� ' II I II a � II ' II � II i I 1 I II ' II t 19'-2" I VV I I ' It IIII I IIII (' II�i O UTILITY SINK O I i l I o© Ell © �© © � NII L 3070 HC BATHROOM / $1O CLOSET I I 9'-6" CEILING CABINETRY BY OTHERS © (2)5 TON M I j FOR DETAILS _8" H AIR HANDLERS ` T 11'-6" ' BREAK ROOM STORAGE J® 9'-6" CEILING CLOSET 11' i ° oil W-6" CEILING 9'-6" CEILING II SALES 2 3 FRAMED 9'-6" CEILING OPENING 0 t 6 -s 2870 1 ' j SEE MECH FOR DETAIL HC BATHROOM O I 9'-6" CEILING 3 770 SERVICE/FLEX 11' SPACE i I 9'-6" CEILING p '' I , CONSTRUCTION 11 9'-6" CEILING 14'-4" OFFICE MANAGER 9'-6" CEILING 2' O O 0 W-6" CEILING SUITE 150 FLOOR AREA CALCULATIONS OFFICE AREA 2,885 S.F. WAREHOUSE AREA 1,030 S.F. TOTAL AREA 3,915 S.F. SHOWROOM 9'-6" ACOUSTIC TILE CEILING 7'-10"- 3070 ' y 3070 U 1 26'-2' O 9'-6" CEILINGI 1 EXIT 0 SALES 1 9'-6" CEILING 1 12'-4" CAD 12'-10" 9'-6" CEILING 10'-4" RECEPTION 9'-6" CEILING Jill 26'-4"litill Jill 2'-6" 1111 II JOHN'S OFFICE 14' 9'-6" ACOUSTIC TILE CEILING I I I I FRAME OUT WALLS TO HIDE ALL COLUMNS OR FRAME OUT INDIVIDUAL COLUMNS �I iI FLOOR AND LIFE SAFETY PLAN SUITE 150 LIFE SAFETY NOTES 1. INSTALL EMERGENCY LIGHTING TO PROVIDE A MINIMUM ONE FOOT CANDLE FLOOR ILLUMINATION. EMERGENCY LIGHTING SYSTEM SHALL BE SO ARRANGED AS TO PROVIDE THE REQUIRED ILLUMINATION AUTOMATICALLY IN THE EVENT OF ANY INTERRUPTION OF NORMAL LIGHTING SUCH AS ANY FAILURE OF PUBLIC UTILTIY OR OTHER OUTSIDE ELECTRICAL POWER SUPPLY, OPENING OF A CIRCUIT BREAKER OR FUSE OR ANY MANUAL ACT, INCLUDING ACCIDENT. A FIRE INSPECTION SHALL WITNESS AN OPERATIONAL TEST ON THE EMERGENCY LIGHTING PRIOR TO FINAL BUILDING APPROVAL 2. LOCKING DEVICES ON REQUIRED EXIT DOORS SHALL NOT REQUIRE THE USE OF A KEY FROM INSIDE THE BUILDING. 3. PROVIDE FIRE EXTINGUISHERS HAVING A MINIMUM RATING OF 2A iOBC FOR EVERY 3,000 S.F. EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF THE EXTINGUISHERS SHALL NOT BE MORE THAN 5 FT. ABOVE THE FLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS THAN V FROM THE FLOOR. TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. FLOOR PLAN NOTES 1. THE OWNER AND GENERAL CONTRACTOR ARE RESPONSIBLE FOR SELECTING AND INSTALLING ALL FLOORING, WALL FINISHES, PAINT COLORS, LIGHTING FIXTURES, PLUMBING FIXTURES AND OTHER FURNISHINGS. 2. ALL PROPOSED WALL DIMENSIONS ARE FROM FINISHED WALL TO FINISHED WALL UNLESS NOTED OTHERWISE. 3. ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE WITH ALL APPLICABLE GOVERNING MUNICIPAL AND REGULATORY AGENCIES, CODES AND REQUIREMENTS. IT SHALL BE UNDERSTOOD THAT ALL INTENDED WORK IS SUBJECT TO REVIEW AND INTERPRETATION BY THE ADMINISTRATIVE AUTHORITY HAVING JURISDICTION. IN NO CASE SHALL WORK BE PERFORMED WiTHOUT THE REVIEW AND WRITTEN APPROVAL OF SAID AUTHORITY. THE CONTRACTOR AND OR OWNER SHALL BE RESPONSIBLE FOR ALL FEES RELATED TO THE ISSUE OF PERMITS, INSPECTIONS AND CERTIFICATES NECESSARY FOR THE EXECUTION AND COMPLETION OF THE WORK. 4. THIS TENANT SPACE IS FOR SOUTHERN POOLS LIFE SAFETY REQUIRED EXITS # OF EXITS REQUIRED (OFFICE) i TOTAL # OF EXITS PROVIDED (OFFICE) i # OF EXITS REQUIRED (WAREHOUSE) 1 TOTAL # OF EXITS PROVIDED i MAX.A L DISTANCE ACTUAL TRAVEL DISTANCE TO EXIT FROM FURTHEST POINT 90 MAX. WAREHOUSE (S-2) TRAVEL DISTANCE TO EXIT 250' ACTUAL TRAVEL DISTANCE TO EXIT FROM FURTHEST POINT 50' OCCUPANCY CLASSIFICATION MIXED OCCUPANCY CLASS: BUSINESS (B) and STORAGE (S-2) OCCUPANCY LOAD FOR SUITE 150 PER 2017 FBC, 6TH ED, TABLE 1004.1.2 OFFICES (BUSINESS) 2885/100 S.F. = 29 OCCUPANTS WAREHOUSE STORAGE (S-2) 1030/500 S.F. = 2 OCCUPANTS TOTAL OCCUPANTS = 31 LIFE SAFETY LEGEND ® ABC FIRE EXTINGUISHER (HANGING) EXIT LIGHT W/ BATTERY BACKUP EMERGENCYT LIGHT W/ BATTERY BACKUP EXIT DIRECTIONAL EXIT LIGHT W/ BATTERY BACKUP - go- "al TRAVEL DISTANCE 8t DIRECTION ROOM FINISH SCHEDULE NO ROOM NAME FLOOR BASE WALLS CEILING N S E W MATERIAL HGT 9 1 OFFICES/RECEPTION TILE VINYL GYP GYP GYP GYP ACOUSTICAL 9'-6" 3 MEN/WOMEN HC TILE VINYL GYP GYP GYP GYP ACOUSTICAL 9'-6" 1 BREAKROOM TILE-f VINYL GYP I GYP I GYP GYP ACOUSTICAL 9'-6" ALL FINISHES TO MEET CLASS "A" FIRE RATING (FLAME SPREAD RETARDANT) DOOR AND HARDWARE SCHEDULE SYMBOL QTY. DOOR TYPE SIZE HARDWARE AO 18 SOLID CORE WOOD DOOR W WOOD FRAME 3'x7' LEVER/ THUMB LOCK ©1 SET DBL. WOOD FRENCH DOORS W/ WOOD FRAME 30"xT LEVER ONLY WALL LEGEND INTERIOR MTL. FRAMED WALL NON BEARING 1 HOUR FIRE RATED WALL NON BEARING EXIST. CMU EXTERIOR WALLS � CAS'rk //os No 59� �7'• ST. E OF � O • e �s 40 JUL 0 3 2018 ERMOCRATES E. CASTILLO, P.E. DATE FL. REG. # 52590 N z W IY W Q m T_ 1 N 1 M I rW V/ Z � 0� J 2 W ti W F- ZM Q U. a W Q0 U W �.�.. �LL LL J a w O 0 06 C:) Z w w V_ 00 m0 W -J ` �/ / u_ U z 0 z FF-- J 0 O E 04 Q — E m u" rn E i � Z U) a>! -v wwroc: o Q to : N 5, a� c4 1W- z o WzOvm_ Oma=, v� 04 1._ J �( ,- --t W Q i co d F- tL W C7 5� DATE: 5/20/18 SCALE: 1/4" = 1' DRAWN: JHR APPROVED: RC SHEET NAME: A-1 SHEET: 2 OF 5 54" MIN. 36" MIN. 12' 42" MIN. 12' MINI 12' MIN. TGRAB BAR GRAB BAR TOILET PAPER L _ J ENLONGATED TOLIET SEAT 0 33" t + O N I N I GRAB BAR AT GRAB BAR AT BACK WALL SIDE WALL 36' 18" 18' MIN. 6" 12" 12" TO WALL 6" PLUMBING! WALL PAPER TOWEL DISPENSOR I _ —— MIRROR USHER HANDLE � I --- i \ I INSULATION 1 Q 7._O" 0 I I LAVA RY 1 iv l CLEAR FLOOR SPA L_ M SPACE 30'x " z 48"x 66" 6' � � I 8" 6" 1 �------ --U MIN. MA I I 17" MIN. ----- ------ J 3070 LAVATORY CLEARANCE OUT SWING DOOR HANDICAP BATHROOMS PLUMBING FIXTURE COUNT FOR SUITE 150 PER 2017 FBC, 6TH ED, TABLE 1004.1.2 OFFICES (BUSINESS) 2885/100 S.F. = 29 OCCUPANTS WAREHOUSE STORAGE (S-2) 1030/500 S.F. = 2 OCCUPANTS TOTAL OCCUPANT LOAD = 31 OCCUPANTS PER TABLE 403.1 (FBC-PLUMBING OCCUPANY B (1) WATER CLOSET & LAVATORY PER SEX PER FIRST 2" VTR I_ 25 PEOPLE, (1) SEVICE SINK AND (1) DRINKING FOUNTAIN —I— SUITE 150 \ 2" VTRI_ I STUBOUT M W.C. LAV. SINK PJDF SUITE 162 h, ., / \ LAV. V. UTILITY SINK W/STUDER )F BREAKR00M NK W/STUDER VENT 0 EXIST. PVC SAN. LINE TO SANITARY SEWER SYSTEM PLUMBING RISER ELECTRIC AND REFLECTIVE CEILING PLAN SUITE 150 GENERAL ELECTRIC NOTES 1. ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR SHALL ENSURE THERE IS AMPLE POWER AND CORRECT PHASING FROM EXISTING TRANSFORMERS PRIOR TO DOING ANY ELECTRICAL WORK 2. PROVIDE WORK NOT SPECIFICALLY SHOWN OR SPECIFIED, YET REQUIRED TO INSURE PROPER AND COMPLETE OPERATIONS OF ALL SYSTEMS AND TO SATISFY THE DESIGN INTENT IN THE WORK AND TO COMPLY WITH ALL APPLICABLE CODES & REGULATIONS 3. LABOR FOR THE INSULATION OF MATERIALS AND EQUIPMENT FURNISHED UNDER THE ELECTRIC CONTRACTOR'S SCOPE OF WORK SHALL BE PERFORMED BY EXPERIENCED MECHANIS OF THE PROPER TRADE AND ALL WORKMANSHIP SHALL BE FIRST CLASS AND SHALL BE INCOMPLIANCE WITH THE SPECIFIC CONTRACT DRAWINGS 4. ALL DESCREPANCIES ON DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER/ ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION 5. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE FOLLOWING CODES AND STANDARDS: 2014 FLORIDA BUILDING CODE, 5TH ED., NATIONAL FIRE ASSOCIATION, NATIONAL ELECTRIC CODE, 2011, NATIONAL ELECTRICAL MANUFACTURES ASSOCIATION. NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION, AMERICAN NATIONAL STANDARDS INSTITUTE, UNDERWRITERS LABORATORIES, AND ALL LOCAL CODES AND ORDINANCES. 6. THE CONTRACT SHALL OBTAIN AND FURNISH ALL PERMITS, AND ARRANGE FOR ALL REQUIRED INSPECTIONS 7. THE CONTRACT DRAWINGS INDICATE THE GENERAL ARRANGEMENTS OF CIRCUITS AND OUTLETS, SWITHCH LOCATIONS, PANEL BOARDS, CONDUITS AND OTHER WORK. FIELD VERIFY ALL DIMENSIONS PRIOR TO STARTING WORK. 8. FIELD COORDINATE EXACT ELECTRICAL CONNECTION POINTS TO EQUIPMENT PRIOR TO ROUGH IN OF ELECTRICAL COMPONENTS 9. THE CONTRACTOR SHALL PROVIDE ALL CHANNEL AND ANGLE SUPPORTING SYSTEMS, HANGERS, ANCHORS, SLEEVES, BRACKETS, FABRICATED ITEMS, AND HARDWARE AS REQUIRED TO PROVIDE SECURE SUPPORT, PER N.E.C. FOR ALL ELECTRICAL COMPONENTS 10. IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED & READY FOR OPERATION 11. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE GENERAL LOCATION OF OUTLETS, EQUIPMENT, AND THE CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND SPACES PERMIT. WHERE CONDUIT RUNS ARE NOT SHOWN ON THE DRAWINGS, COORDINATE CONDUIT RUNS WITH OTHER TRADES. SIMPLIFY INSTALLATION WHERE EVER POSSIBLE, BUT SUBJECT APPROVAL BY DESIGNER AND OR OWNER. IT IS NOT WITHIN THE SCOPE OF THESE DRAWINGS TO SHOW ALL NECESSARY OFFSETS, BENDS, AND OBSTRUCTIONS. THE DRAWINGS ARE NOT INTENDED TO BE SCALED REFER TO WRITTEN DIMENSIONS. 12. WHERE DISCREPANCIES OCCUR, THE DEIGNER/ENGINEER SHALL BE NOTIFIED PRIOR TO DOING THE WORK. 13. SEAL ALL PENETRATIONS OF FIRE RATED WALLS WITH U.L. APPROVED FIRESTOPPING MATERIAL TO PROVIDE AN EQUAL RATING. 14. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS TO PREFORM ALL WORK NECESSARY FOR THE COMPLETE EXECUTION OF THE ELECTRICAL WORK AS SHOWN ON THE DRAWINGS 15. PANEL SCHEDULES AND RISERS ARE GENERIC. ELECTRICIAN TO ENSURE PANELS AND RISERS MEET CURRENT CODES AND COMPLY WITH 2O14 NEC. ELECTRICAL SCHEDULE. DESCRIPTION ITEM REMARKS 2'x4' DROP IN LIGHT ® (4) LED FLUORESCENT CAN LIGHT STATIONARY/ SWIVEL LED 2'x4' HANGING LIGHT N LONG 6 BULB LED ® WAREHOUSE ONLY EXIT LIGHT W/ EMERGENCY LIGHTS BATTERY BACK UP EMERGENCY LIGHTS IFZ� BATTERY BACK UP EXHAUST FAN (a VENT TO EXTERIOR OF BLDG. 50 CFM DUPLEX OUTLET q? 120 VOLTS GFI OUTLETS �G 120 VOLTS WALL SWITCH (2-WAY) 3 3 POLE WALL SWITCH (1-WAY) SINGLE POLE CAT 5 OUTLET OWNER TO LOCATE SINGLE OUTLET ® 220 VOLTS ♦ ENS -- No >i 1 •• e 52 0 if ATE o • ����. j>� f ,i. + •i A U EN.e�� JUL '0 3 2018 °j tof�►►r'��e co Z O W w T_ Ill z vJ Q 0 a" _ (j NW z L.L W J U� 06 LL U 0— L.L OU W W ♦♦w _I VJ W N 1 co I— I-- Z M 0 Q F- 0 LL Q J 0 W a. Of U) 0 O LL Z � Q In 0 E N � co U Z E f— _I � cc LL E Z rn o� �wIZ- J Z N N uj cv o QU):N U) m 0 U) Z o S wZZ0 q- U Law a �W MQF- DATE: 5/20/18 SCALE: 1 /4" = 1 APPROVED: RC SHEET NAME: ERMOCRATES E. CASTILLO, P.E. DATE FL. REG. # 52590 ELEC SHEET: 3 OF 5 DUCT PLACEMENT DETAIL INLINE SUPPLY BRANCH 21 SUPPLY BRANCHES E AIR Flow PERPENDICULAR SUPPLY TRUNK NOTE: 14--N ALL SUPPLY DUCTS MUST HAVE A MIN. OF 2' DISTANCE BETNEEN EACH COLLAR MIEN APPLICABLE EXCEPTION: MIEN BRANCHES ARE S1RAK,HT AND PUFUU 1LAR FROM EACH OTHER. MIN. R-6, 1 1/2" FIBERGLASS DUCT OR FLEX IN AT11C OR UNCOND. SUPPORTS PER,, FBCM 603.10 FLEXIBLE DU CEILING EXHAUST FAN DETAIL GOOF CURB FLAT ROOF CAP ROOF CEILING/ROOF FLASHING ^MIN. 4" EXH. DUCT FRAMING 4" EXHAUST DU SUPPLY DUCT SPIN -IN FITTING WITH VOLUME DAMPER REDUCING FITTING SUPPLY DUCT \-AIR GUIDE 24"X24" LAY -IN DIFFUSER (TYPICAL) EXTERIOR LINER SEAL AND FASTEN TO DUCT TRUNK AS PER 2014 FBCM SECTION 603 TYPICAL DUCTWORK BRANCH CONNECTION DUCT HANGER WIRE 12 GAUGE WIRE SUPPORTS DUCT INSULATION—P FBCM SECTION 604 DUCT WORK 3" MAX. EXTENSION EA. SIDE TYPICAL DU LEGEND ® SUPPLY DIFFUSERS ®—RETURN AIR DIFFUSER —THERMOSTAT Hi —BALANCE DAMPER O/A RIGID DUCT RETURN FLEX DUCT SUPPLY FLEX DUCT LSUPPORTS PER FBCM 603.10 ANGER CHANNEL 1.5" WIDE (min.) ORK SUPPORT DETAIL Install as per 2017 FBCM Secure condensing unit to concrete pad with 1' wide galvanized sheetmetal straps min. 22 gauge, f10 screws 3/4' long with gasketed washers/ Ta[cpm 1/4' x 1 1/2' . For units between 2e and 36', three screws shall be used per side. 4" concrete pad Provide 4 pvc sleeve of-- pennetration and seal ends watertight Refrigerant lines metal-\ straps secured to IN Building wall Protective metal jacket — paint to match Arch. Condensing -Unit ■ A" - Neoprene vibration isolators Condensing Unit Mounting Detail LTA FAN CEILING GRILLE / O O�t� ------ ----- ---- 12'xl4' OHD----�-- -- ------ ----- -- — II L200 AMP PANEL II II 5" DUCT FOR OUTSIDE AIR I 1 VENT TO OUTSIDE W/BIRD I I SCREEN 153 CFM O/A II II 1/2" PVC CONDENSATION I I DUNE TO BE IN SAME CHASE I AS REFRIGERANT LINES. CONDENSATION LINE TERMINATES IN GRASS AREA I II I1 Im IIII AHU #2 4 ton IIII Carrier or Eqv. � IIII STUB OUT UTILITY SINK ONLY III I El r AHU 11 4 ton LW or Eqv. I EF-1 70 cfm 1 OVIR W/4 duct 22x12 RIGID 1 GID 8x4 20"flex 40 cfm 6"flex 2424 9"flex 1533 cm 6"flex 2•0 flex 269 cm �X�,24x4 2424 2424 2424 1533 cm II I 221 cfm 202 cfm 9 flex x^0 8x4 I 30 cfm 6 2424 OEF-1 70 cfm V [R W/4"duct c2 � II N II 12"flex 14"flex o 9"flex 2424 220 cfm 2424 2488 cfm 01 SUITE 150 2424 III I 6»flex 8 flex 2424 8 III) 2424 117 cfm 8"flex IIII II 151 cfm N 24x24 24x24 X 184 cfm co HI 2 x 24 2"flex 14"flex 2424 I i 9"flex 24 x 24 8"flex424 220 c fm 10 I I II 2424 151 cfm N 24 x 24 24x24 X 14 8"flex 171 0 IIII ill 24x24 III T 180 cfm i I II 18"flex 18"flex 2424 12x12RIGID I "flex T121x 07x24 cfm 17,ex 24x24 12"flex 24x24 III 289 cfm IIII IIII 2424 2424 1111 345 cfm 345 cfm I II II HVAC PLAN SUITE 150 GENERAL HVAC NOTES (COMPLIANCE W/2017, 6th ed. F.B.C.M.) 1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, A MIN. OF 4 INCHES ON EACH SIDE IS SUFFICIENT. 2017 F.B.C.M. SEC. 603.1.3 2. ALL DUCT SYSTEMS INSTALLED IN "NON -CONDITIONED" AREAS SHALL BE CONSTRUCTED WITH APPROVED MATERIAL AND OF A VALUE OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB & MASTIC "OR" APPROVED TAPES THAT EXTEND NOT LESS THAN 1 INCH AND LABELED IN ACCORDANCE WITH THE UL-181 A, PART 1 FOR DUCT BOARD OR UL 181 B, PART 1 FOR FLEX. ALL CLOSURES 100% AND INSTALLATIONS SHALL BE INSTALLED AS PER 2017 F.M.C.M. CHPT. 6, SEC. 603 ALL THRU-WALL, FLOOR & CEILING PENETRATIONS INTO THE DUCT SECTION SHALL CONTAIN A BRANCH DUCT FABRICATED OF RIGID FIBROUS GLASS DUCT BOARD OR RIGID METAL AND IS SEALED TO BOTH DUCT SECTION AND GRILLE SIDE WALL SURFACE. THE BRANCH DUCT SHALL BE FABRICATED AND ATTACHED IN ACCORDANCE WITH M603.3 OR M603.4.2 RESPECTIVE TO THE DUCT TAPE USED. 3. ALL DUCT TRUNK 90 DEGREE TURNS OR TEES, SHALL HAVE TURNING VANES. 3 PIECE OR 45 DEGREE TURNS CAN BE USED IN PLACE OF 90 DEGREE TURNS AND DO NOT NEED TURNING VANES. 4. ALL REGISTERS, GRILLES & DIFFUSERS MUST BE TESTED IN ACCORDANCE WITH ASTM E 84, AND VOLUME DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN DUCTS OR AT EACH INDIVIDUAL REGISTER, GRILLE OR DIFFUSER. 5. AIR HANDLERS (OVER 2000 CFM) SHALL HAVE A SMOKE DETECTOR INSTALLED IN THE SUPPLY. F.B.C.M. 2017 CHAPTER 6, SEC. 606.2.1. WHEN TWO AIR HANDLERS SHARE A COMMON SUPPLY OR RETURN "AIR DUCT' OR "PLEMUN" AND THE TOTAL CFM'S ARE GREATER THAN 2000, A SMOKE DETECTOR SHALL BE INSTALLED IN THE SUPPLY AND RETURN AS PER F.B.C.M. 2017 SEC. 606.2.3 AND BE IN ACCORDANCE W/NFPA 72 SMOKE DETECTOR TEST STATIONS SHALL HAVE A TROUBLE INDICATOR LIGHT, INUNDATING ANY AIR DUCT TROUBLE PER NFPA 90A 2014, CHPT 6. NOTE: A "PLEMUN" CAN NOT BE USED AS AN OCCUPANCY SPACE OR STORAGE AREAS. AS PER NFPA-90A, SEC. 4.3.10.1.1 6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO F.B.C.M. 2014 CHAPTER 6. 7. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT OUTLET, OR SANITARY SEWER VENT OUTLET. ALL OUTDOOR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS THAT CLOSE WHEN VENTILATION NOT OPERATING. F.B.C.M. 2017, SEC. 403.5 8. ALL EXHAUST DUCTS, SHALL BE CONSTRUCTED OF METAL AND COMPLY WITH F.B.C.M. 2017 CHAPTER 5, SEC. 501.4 9. ALL EXHAUSTED BATHROOMS, CLOSETS & STORAGE ROOMS SHALL HAVE UNDER CUT DOORS OR A METHOD FOR MAKE UP AIR TO BE RETURNED EQUAL TO THE AMOUNT OF CFM'S EXHAUSTED. F.B.C.M. 2017 CHAPTER 6, SEC. 601.4 10. CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO A STREET, ALLEY OR OTHER AREA AS TO CAUSE A NUISANCE. MUST TERMINATE A MIN. OF I &' FROM EXT. WALL CONDENSATE DRAIN LINE SHALL NOT BE LESS THAN 3/4 INCH DIAMETER AND SHALL NOT DECREASE IN SIZE. 2017 F.B.C.M. CHPT. 3, SEC.307 PER AUTHORITY OVER JURISDICTION CONDENSATE DRAIN MAY DRAIN TO A STORM SYSTEM, UTILITY SINK, OR SEWER BY APPROVED MEANS. ALL HORIZONTAL PRIMARY DRAIN LINE WITHIN UNCONDITIONAL AREA SHALL BE INSPECTED PER FBCM 2014 CHPT. 3, SEC.307 AUXILIARY DRAIN PAN OR SECONDARY DRAIN LINE MAY BE REQUIRED WHERE DAMAGE TO ANY BUILDING MAY RESULT FROM OVERFLOW OR STOPPAGE. AUXILLARY DRAIN PAN MUST HAVE A MIN. DEPTH OF 1.5" AND BE A MIN. 3" LARGER THAN UNIT OR COIL AND HAVE SEPARATE DRAIN LINE. AN AUX. PAN W/O SEPARATE DRAIN LINES SHALL BE EQUIPPED WITH WATER LEVEL DETECTION DEVICE FOR SHUT OFF PRIOR TO OVERFLOW. ALTERNATIVE TO SEPARATE DRAIN LINE: A WATER LEVEL DETECTION DEVICE THAT WILL SHUT EQUIPMENT PRIOR TO OVERFLOW OF PAN WATER LEVEL DETECTION DEVICE SHALL CONNECT TO DRAIN PAN AT A HIGHER LEVEL THAN THE PRIMARY DRAIN CONNECTION. CONDENSATE DRAIN LINE CAN BE STRAPPED WITH 2" NYLON STRAP AND SUPPORTED EVERY 10' VERTICAL AND 3' HORIZONTAL 11. REFRIGERANT PIPING FOR REFRIGERANT LINES SHALL BE INSULATED TO A THERMAL RESISTIVELY OF AT LEAST R=4HR. SUCTION LINE MUST BE INSULATED IN ACCORDANCE WITH ASTM E96. AS PER THE F.B.C.R. 2017 CHAPTER 3, SEC. 307 12. ALL AIR DISTRIBUTION COMPONETS WILL BE INSTALLED IN ACCORDANCE TO 2017 F.B.C.M. 13. IF HVAC EQUIPMENT OTHER THAN SPECIFIED BY DESIGNER IS SUBSTITUTED, ITS CAPABILITIES OF BTU HEAT REMOVAL MUST BE EQUAL TO THE EQUIPMENT SPECIFIED BY THE HVAC DESIGNER. THE HVAC DESIGNER WILL NOT BE RESPONSIBLE FOR ANY SYSTEM NOT INSTALLED ACCORDING TO PLANS. H.V.A.C. EQUIPMENT SCHEDULE SUITE A/C MFG-MODEL 'OR EQUAL' NO. "OR EQUAL" SENSIBLE LATENT TOTAL-BTUH COOLING/HEATING SEER CFM 150 AHU #1 CARRIER CH14NBO48/FB4CNP048 34.5 11.5 4.0 TONS 48,000 10 KW 45,500 14 1531 150 AHU #2 CARRIER CH14NB048/FB4CNP048 34.5 11.5 4.0 TONS 48,000 10 KW 45,500 14 1541 OUTSIDE AIR CALCULATION SUITE S.F. AREA CFM/PRSN + CFM/FT2 MIN. CFM AHU #1 1529 5.0 X 12 + .06 X 1529 151 AHU #2 1356 5.0 X 12 + .06 X 1356 141 AIR BALANCE SCHEDULE AHU1 OUTSIDE AIR INTAKE CFM +151 SUITE 150 SUPPLY AIR CFM +1531 RETURN AIR CFM —1612 EXHAUST CFM —70 TOTAL SUITE PRESSURE "0" CFM AHU2 OUTSIDE AIR INTAKE CFM +141 SUITE 150 SUPPLY AIR CFM +1541 RETURN AIR CFM —1612 EXHAUST CFM —70 TOTAL SUITE PRESSURE "0" CFM EXHAUST FAN SCHEDULE FAN MFG. TYPE CFM VOLTS DUCT DIA 2 BROAN OR CEILING 70 120 4" A T EXHAUST FAN UNITS MUST COMPLY WITH SEC. 307 OF THE F.B.C.M. 2017 FOR AUX. DRAIN PAN OR FLOAT SWITCHES. FRESH AIR: UNITS MUST BE EQUIPPED WITH AUTOMATIC SHUTOFF DAMPERS WHEN UNITS ARE NOT IN USE. 07 Z O U) ul x r- I N I th �♦W VJ D 0 2 W ti Z Z M CL U �0 C) `` LL = I) 0 0 U-)Z �08 0 ti E N O CM V Z E LL 0 Z fn N d � c�CDtiUa N T J W W ~ N O >aco Q U) +! N >+ U) Z I-WWm 0PZo 0 Woos U O 2 a _ WQW J W 2 MQI-aW DATE: 5/20/18 SCALE: 1 /4" = 1' DRAWN: JHR APPROVED: RC R 1 . �;% JUL 0 3 2018 SHEET NAME: HVAC ERMOCRATES E. CASTILLO, P.E. DATE FL. REG. # 52590 SHEET: 4 OF 5 ``,ASi''�, E S� o '�i ` No 52590 !' STAT F ;��e PANEL SCHEDULE FOR UNIT 150 SURFACE MOUNT 208 120V, 3 PH 4W 200 AMP SIEMANS TYPE "EQ" BRANCH CIRCUIT 10,000 A.I.C. INTEGRATED BRANCH CIRCUIT CIR.# BKR H NEUT GND. WIRE COND DESCRIPTION LOAD LOAD DESCRIPTION COND GND. NEUT H BKR CIR.# KVA KVA WIRE 1 20 12 12 12 1 /2"MC OFFICE RECEPTICALS 1.5 1.5 WAREHOUSE RECEPTICALS 1 /2"MC 12 12 12 20 2 3 20 12 12 12 1 /2"MC OFFICE RECEPTICALS 1.5 1.5 WAREHOUSE RECEPTICALS 1 /2"MC 12 12 12 20 4 5 20 12 12 12 1 /2"MC OFFICE 1.5 1.5 WAREHOUSE 1 /2"MC 12 12 12 20 6 RECEPTICALS LIGHTS 7 20 12 12 12 1 /2"MC OFFICE 1 5 1 5 WAREHOUSE 1 /2"MC 12 12 12 20 8 RECEPTICALS LIGHTS 9 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 1.5 WATER COOLER 1 /2"MC 12 12 12 20 10 11 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 1.5 REA M GFI RECEPTICAL 1 /2"MC 12 12 12 20 12 13 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 1.5 OUTSIDE GFI GFI RECEPTICAL 1 /2"MC 12 12 12 20 14 15 20 12 12 12 1 /2"MC OFFICE 1.5 16 LIGHTS 33 BLANK BLANK 34 35 30 10 0 10 /4"MC ACU 2.5 BLANK 36 37 30 10 0 10 4 /'MC BLANK 38 39 40 10 0 10 /4"MC AHU 5.0 5.0 EWH 3/4-MC 10 8 3 30 40 41 40 10 0 1 10 /4"MC EWH 3/4"MC 10 8 3 30 42 EQUIPMENT SERVED CONN. LOAD DF DEMAND LIGHTING 9.0 KVA TOTAL 125% 11.3 KVA RECEPTACLES - GENERAL 13.5 KVA DEMAND 100% 13.5 KVA A/C, CONDENSING & HWH 12.5 KVA AMPS 100% 12.5 KVA TOTAL EQUIPMENT SERVED 35.0 KVA 1 200 132.50 KVA TOTAL DEMAND LOAD 37.3 KVA (1000)/1.73 x 208v = 103.6 AMPS TOTAL CONNECTED LOAD I PANEL SCHEDULE FOR UNITS 162, 186, 198 &: 222 SURFACE MOUNT 208/120V, 3 PH/4W/150 AMP SIEMANS TYPE "EQ" BRANCH CIRCUIT 10,000 A.I.C. ONTEGRATED BRANCH CIRCUIT CIR.# BKR H NEUT GND. COND DESCRIPTION LOAD LOAD DESCRIPTION COND GND. NEUT H BKR CIR.# WIRE KVA KVA WIRE 1 20 12 12 12 1 /2"MC _ LIGHTING OFFICE (OFFICE) 1.5 1.5 WAREHOUSE RECEPTICALS 1 /2"MC 12 12 12 20 2 3 20 12 12 12 1 /2"MC LIGHTING OFFICE (OFFICE) 1.5 1.5 WAREHOUSE RECEPTICALS 1 /2"MC 12 12 12 20 4 5 20 12 12 12 1 /2"MC RECEPTICALS 1.5 1.5 WAREHOUSE 1 /2"MC 12 12 12 20 6 (OFFICE) LIGHTS 7 20 12 12 12 1 /2"MC _ RECEPTICALS 1.5 1.5 WAREHOUSE 1 /2"MC 12 12 12 20 8 (OFFICE) LIGHTS 9 20 12 12 12 1 /2"MC WATER COOLER 1.5 1.5 OUTSIDE GFI R CC EPT FAL 1 /2"MC 12 12 12 20 10 11 20 12 12 12 1 /2"MC - _ 12 13 15 20 20 12 12 12 12 12 12 1 /2"MC 1 /2"MC _ 14 33 BLANK BLANK 34 35 - BLANK -- - BLANK 36 37 - BLANK BLANK 38 39 40 1 10 0 10 3/4"MC AHU 5.0 2.5 ACU 3/4"MC 10 8 3 30 40 41 40 10 0 10 3/4 "MC3 3/4"�Cl 8 30 42 EQUIPMENT SERVED CONN. LOAD DF DEMAND LIGHTING 6.0 KVA TOTAL 125% 7.5 KVA RECEPTACLES - GENERAL 9.0 KVA _ DEMAND 100% 9.0 KVA A/C, CONDENSING & HWH TOTAL EQUIPMENT SERVED 7.5 KVA 22.5 KVA AMPS 200 100% 7.5 KVA 24.0 KVA TOTAL DEMAND LOAD 24.0 KVA (1000)/1.73 x 208v = 66.7 AMPS TOTAL CONNECTED LOAD _ PANEL SCHEDULE FOR UNITS 162, 186, 198 & 222 SURFACE MOUNT 208 3 PH, 4W/150 AMP //120V, SIEMANS TYPE "EQ" 10,000 A.I.C. (INTEGRATED) CIR.# BKR POLES TRIP GND. COND DESCRIPTION LOAD CALCS DESCRIPTION COND GND. TRIP POLES BKR CIR.# _ WIRE AMPS WIRE 1 20 1 8 12 MC 1.5 1.5 LIGHTING MC 12 8 1 20 1 2 _ WAREHOUSE _ 3 20 1 8 12 MC 1.5 15 LIGHTING MC 12 8 1 20 4 WAREHOUSE 5 20 1 8 12 MC 1.5 1.5 RECEPTICALS (WAREHOUSE) MC 12 8 1 20 6 7 20 1 8 12 MC 15 15 RECEPTICALS (WAREHOUSE) MC 12 8 1 20 8 9 20 1 8 12 MC 1.5 GFI RECEPTICALS MC 12 8 1 20 10 11 40 3 8 10 3/4 _ AHU _(OUTSIDE)__ CU 3/4 10 8 3 30 12 5.0 2.5 13 40 3 8 10 3/4 AHU Cu 3/4 10 8 3 30 14 EQUIPMENT SERVED CONN. LOAD DF DEMAND LIGHTING 6.0 KVA TOTAL 125% 7.5 KVA RECEPTACLES - GENERAL 9.0 KVA DEMAND 100% 9.0 KVA AHU AND CU 7.5 KVA AMPS 100% 7.5 KVA TOTAL EQUIPMENT SERVED 22.5 KVA 200 24.0 KVA TOTAL DEMAND LOAD 24.0 KVA(1000)/1.73 x 208v = 66.7 AMPS TOTAL CONNECTED LOAD PANEL SCHEDULE FOR UNITS 174 & 210 SURFACE MOUNT 208//120V, 3 PH/'4Wj200 AMP SIEMANS TYPE "EQ" BRANCH CIRCUIT 10,000 A.I.C. INTEGRATED BRANCH CIRCUIT CIR.# BKR H NEUT GND. COND DESCRIPTION LOAD Lj OAD DESCRIPTION COND GN NEUT NUT H BKR CIR.# WIRE KVA I KVA WIRE 1 20 12 12 12 1 /2' MC OFFICE 1.5 _ WAREHOUSE 1 /2"MC 12 12 12 20 2 RECEPTICALS OFFICE RECEPTICALS WAREHOUSE 12 4 3 20 12 12 12 1 /2"MC 1.5 1.5 1 /2"MC 12 12 20 RECEPTICALS RECEPTICALS 5 20 12 12 12 1 /2"MC OFFICE RECEPTICALS 1.5 1.5 WAREHOUSE LIGHTS 1 /2"MC 12 _ I 12 12 20 6 - 7 20 12 12 12 1 /2"MC KITCHEN 1.5 1.5 WAREHOUSE 1 /2"MC 12 1 12 12 20 8 RECEPTICAL LIGHTS 9 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 1.5 WATER COOLER 1 /2"MC 12 12 12 20 10 11 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 1.5 _ GFI RECEPTICALS (OUTSIDE) 1 /2"MC 12 12 12 20 12 13 20 12 12 12 1 /2"MC OFFICE LIGHTS 1.5 BLANK _ 14 15 - BLANK - ---BLANK 16 _T 33 BLANK BLANK 34 35 30 10 0 10 3/4"MCI BLANK 36 ACU 2.5 37 30 10 0 10 3/4"MCI BLANK 38 39 40 10 0 10 3/4"MCI EWH - 3/41MC 10 8 3 30 40 AHU 5.0 5.0 i 40 10 0 10 3/4"MC EWH 3/4C "M 10 8 3 30 42 EE:IMENTSERVED CONN. LOAD DF DEMAND - -- --- ---� 9.4 KVA -- -- - LIGHTING 7.5 KVA TOTAL 125% RECEPTACLES - GENERAL 12.0 KVA DEMAND 100% 12.0 KVA A/C, CONDENSING & HWH 12.5 KVA AMPS 100% 12.5 KVA TOTAL EQUIPMENT SERVED 32.0 KVA 200 33.9 KVA TOTAL DEMAND LOAD _ 33.9 KVA(1000)/1.73 x 208v = 94.2 AMPS TOTAL CONNECTED LOAD 200 A 150 A 200 A 150 A 200 A 150 A 200 A 150 A 100 A TENANT TENANT TENANT TENANT TENAN TENANT TENANT TENANT TENANT PANEL PANEL PANEL PANEL PANEL 1 PANEL PANEL PANEL PANEL #234 1 , 222 #210 #198 #150 #162 #174 #186 HP MODEL #37MM42OR12 OA 2.5" CONDUIT W/(4) 250 ALUM. W/#4 Cu GROUND © (9) METER BASES W/ FUSIBLE DISCONNECTS © (3) 3.5" CONDUITS W/(3) SETS OF 4x 500 MCM ALUM. W/ THHN 75°C INSULATION OD 2.5" CONDUIT W/(4) 250 ALUM. W/#4 Cu GROUND TO EA. BAY 0 3/0 cu TO NEUTRAL AND GROUND. BLOCK IN WIRE WAY O (2) 5/8" x 10' GROUND RODS 6' APART (MIN). © 3/0 Cu WIRE TO TIE INTO FOOTER STEEL H0 3/0 Cu GROUND WIRE TO METAL BLDG. MAIN FRAME STEEL F210 F198 1200 AMP MAIN DISCONNECT 3 PH W/SHUNT TRIP & SURGE ;OTECTION DEM MODEL # 3MC B 120OR N186 p I P f174 I FROM - TRANSFORMER 310 co TO FR Fp pTFR .cr�l RF 150 -MODEL #35MM120R12 MODEL #37MM42OR 12 ELECTRIC RISER �y lu u.._.- --- -- -� -- rUNISTRUT RACK FOR 220 POWER,®� �®® GFI AND DISCONNECT PER UNIT balm- 4000, 0 60' 60' `I E 00, � D c I0 U a MECH. E] ❑ 10CLOSET CLOSET MECH. MECH. MECH. a e9. �C OSET CLOSET C OSjETD � CLOSET CLOSET CLOSET 0 OR/, SUITE 234 SUITE 222 SUITE 210 SUITE 198 SUITE 186 SUITE 174 SUITE 162 SUITE 150 --14 e, A_/C CONDENSOR LOCATIONS, REFRIGERANT LINES & ELECTRIC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ° �> ° S ,i N 52590 - �z. STATE 4�j fill JUL 0 3 2018 co z w W U) C) W J O� W W Q U W W U z UL CL LL U O- L.L 0(.) U W W W 0 ti H ti Z N Q O aL .J 0 :5 LL U 0 U)O LL U-) Q U) ti E N O M U Z E m Fes- �" rn E Z cn uN O�o� J Z_ ^ rn � W � ►`' N O < u) : N 5, (A Z F- w ij ti m - p wzo wzO'T � U oa �v_ � 2 NF-J 0 Q F- u_ w Y v i 96 DATE: 5/20/18 SCALE: 1 /4" = 1 DRAWN: JHR APPROVED: RC SHEET NAME: ELEC ERMOCRATES E. CASTILLO, P.E. DATE FL. REG. # 52590 SHEET: 5 OF 5