Loading...
HomeMy WebLinkAbout610 W 9 St 147-876 ElectricalI* o o 20V CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: 17-e< 010 10 Documented Construction Value: $ 49,304.09 Job Address: 01 WEST 9TH STREET SANFORD Historic District: Yes No Parcel ID: 25-19-30-5AG-1009-0060 Residential X Commercial Type of Work: New [A Addition Alteration Repair Demo Change of Use Move Description of Work: INSTALL NEW 1000 AMP ELECTRICAL SERVICES FOR 16 UNIT APARTMENT Plan Review Contact Person: JOSEPH HILLERY SR Title: GC Phone: 407-330-7104 Fax: 407-328-8055 Email: JMHillery@RLHManagement.com Property Owner Information Name COASTLINE APARTMENTS LLC Street: 815 S FRENCH AVE City, State Zip: SANFORD FL 32771 Phone: 407-322-0216 Resident of property? : NO Contractor Information Name L&C ELECTRICAL SERVICES INC; LC GIBBS Phone: 407-468-1307 Street: 4813 LAKE RIDGE ROAD Fax: City, State Zip: ORLANDO FL 32808 State License No.: Architect/Engineer Information Name: N/A Phone: Street: City, St, Zip: Bonding Company: N/A Address: Fax: E-mail: Mortgage Lender: N/A Address: ER13013736 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: Th Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application a NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 0 %7 _ /2-/,. -/ ? Signature of Owner/Agent Date Contractor/Agent's Name a-6- I ' PAY 01sjo" , ANNETTE BLAND Lw-w Notary Public State o1 Flaids Notary Public State of FIorIOaMy Comm. Expires Dec 26.2017 Commission # GG 060623 Commission I FF 079286 My Comm. Expires Jan 16. 2018 N•`•`r Bat e0TIM*Na MItittlayA m Owner Agent is Personally nown toy Me or Contractor/Agent is ersonally Known to Me or Produced ID Type of ID Produced ID — Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Flood Zone: Min. Occupancy Load: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application 4 RLHIMLicense #: CGC 1512297 P.O. Box 625 Sanford, FL 32772-0625rMyGCOMLHManaQement.com CONSTRUCTION COMPANY Phone 407-330-7104 Reliable Luxury Habitations Fax 407-328-8055 Date: 12/06/17 Trade Contractor Purchase Order & Notice to Proceed Page 01 of 01 Trade Contractor: LC Gibbs Company Name:LBC Electrical Services, Inc Job Number: WO#701 Property Owner: coastline Apartment LLc Property Address: 610 W 9th Street Work Phone: 407-468-1307 Cell Ph. 407-468-1307 City: Sanford, FL 32771 Email: LCgibbs210@aol.com Fax Phone: City/County Permit #: 17-876 Contractor: Contact Person: Address: Email Address: Phone Number: Project Name: Project Location: RLH Construction JM HILLERY P.O. Box 0626, Sanford, FL 32772-0625 JMHillery(cD-rlhmanagement.com 407-330-7104 Maple Street Apartments Work Order #: RFQ-701 610 W 9th Street Sanford, FL 32771 Quote Due Date: 12/01/17 Project Manager(s): RT Hillery Scope: Please see Schedule A with inspection report and work order #4. Acceptance of Agreement After review of the above referenced property and scope of work your company shall furnish all Labor & Materials for a lump sum of $49,304.09 for stated work outlined in the attached Quote Work Order#: RFQ- 701 Date 12/01/17. All work will be in accordance with state and local codes and will be quality workmanship. Payment Schedule: 1st payment $19,721.65 2nd payment 14 791,22 3rd payment 14 791,22 1st payment 40%, 2nd payment 30% 3rd payment 1U. after final inspection passed Work shall start on: December 07, 2017 and shall be completed on or prior to: May 20, 2018 ; d all work is not completed and passed final inspection by Sp in on agreed completion date Trade Contractor agrees to pay a penalty up to $250 00 per day.) The stated prices, specifications and conditions are satisfactory and are hereby accepted. Signature: waned Date: 12/06/17 Trade Contractor Owner/Agent I authorize the above company to do the work as specified above. Signature: >IL zzj - _ Date: 12/06/17 RLH Authorize Agent PERMIT # ( CITY OF SANFORD BUILDING & FIRE PREVENTION- DIVISION EARLY START AUTHORIZATION — APPLICATION/PERMIT Project Name• (1 oAS M 14JF B'r r' % 1 %S Date: lfsZg 7 Project Address: tP ly S I Irc, STD'^ Contractor Name: EARLY START AUTHORIZATION CONDITIONS City of Sanford and the Owner/contractor listed agree to the following: I. A complete building permit application and plans shall be submitted at the time of the request for Early Start Authorization. 2. This Early Start Authorization is for interior work or other work as determined by the Building Official. 3. Work must comply with any and all other local, state and federal agencies related to the development and construction proposed and compliance with asbestos NESHAP regulations must occur for all demolition work. 4. Work shall not be concealed and must remain open for all necessary inspections. At the time of inspections, any work concealed shall be uncovered. 5. The contractor acknowledges that all subcontractors will be properly licensed and have current worker's compensation coverage. 6. All subcontractors are responsible for pulling their own permits. 7. Inspections of work for any construction trade will not be made until a permit has been issued for the trade. 8. The Early Start Authorization does not guarantee that construction plans will be approved as submitted. All work done prior to the issuance of the required permits shall be at the Owner's/Contractors risk. 9. The Owner/Contractor acknowledge that additional fees, including but not limited to impact and zoning fees, may be due at the time of building permit issuance, and or prior to Certificate of Occupancy. 10. The Owner/Contractor acknowledge that additional site improvements, including but not limited to installation of a grease trap, accessible parking and landscaping, may be required at the time of building permit issuance. 11. The Owner/Contractor agree to indemnify and hold the, City of Sanford/Agents free and harmless from any and all claims, causes of action, damages, losses penalties or costs, including but not limited to, all attorneys fees (whether from litigation or administrative proceeding, including cost and fees on appeal), with respect to any person or government authority arising out of, either directly or indirectly, the construction or operation at the premises covered by the Early Start Authorization, whether the liability, loss or damage is caused by, or arises out of, the negligence or the City of Sanford/Agents or its officers, agents, employees, or otherwise. 12. If the City of Sanford/Agents shall be subject to any claim, demand or penalty or become a party to any suit or other judicial or administrative proceeding by reason of any claimed act or omission by any party, or by reason of any act occurring on the subject premises, or by reason of any omission with respect to the construction or operation on the subject premises, the Owner/contractor shall indemnify and hold City of Sanford/Agents harmless against all judgments, settlements, penalties and expenses, including attorney's fees, court costs and other expense of litigation of defense relating to such claim or litigation or administrative proceeding, at the election of the City of Sanford/Agents, the Owner/Contractor shall also defend the City of Sanford. 13. It is understood and hereby acknowledged between the parties hereto that the City of Sanford/Agents shall not be liable for any act or other obligation to the Owner/Contractor. 14. This Early Start Authorization will terminate upon the issuance of a Building Permit for property covered under this Early Start Authorization; however, this agreement shall remain in effect for all events occurring prior to the issuance of the Building Permit. By signing this Early Start Authorization Application, the undersigned acknowledges and agrees to condition I through 14. I---- 3 ' ._/, Z Contractor Signature Owner Signature Date No woar pis f 1 PB yip —/ 7 S ve- 4p h , f COUNTY OF SEMINOLE I O 5 IMPACT FEE STATEMENT STATEMENT NUMBER: 17100003 BUILDING APPLICATION #: 17-10000318 DATE: May 25, 2017 BUILDING PERMIT NUMBER: 17-10000318 1 U lQ UNIT ADDRESS: W 9TH ST 610 25-19-30-5AG-1009-0060 I/y a too TRAFFIC ZONE:022 JURISDICTION: SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: N OWNER NAME: ADDRESS: 1•f p APPLICANT NAME: COASTLINE APARTMENTS LLC ADDRESS:ADDRESS: 815 S FRENCH AVE SANFORD FL 32771 I- U LAND USE: DEMO 2 SFR REBUILD APT BLDG TYPE E: DESCRIPTION: WORK CITY-SANFORD i - SPECI NOTES: 610 W. 9TH ST / DEMO 2 1989 SFR'S / REBUILD 16 UNIT APT BLDG FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUETYPEDISTSCHEDRATEUNITSTYPE ROADS-ARTERIA CO -WIDE ORD Apartment* 435.00 16.000 dwl unit 6,960.00 ROADS -COLLECTORS /A Apartment* .00 16.000 dwl unit FIRE RESCUE N 00 LIBRARY CO -WI ORD 00 Apartment* 54.00 16.000 dwl unit 864.00SCHOOLSCO -WIDE D AApsrtment* 2,100.00 16.000 dwl unit 33,600.00PIICCN/A LAW ENFORCE N/A 00 DRAINAGE N/A 00 CREDIT FEES: 00 SCI LIBRARY C Single Family Housing 54.00 2.000 dwl unit 108.00- SCI SCHOOLS R Single Family Housing 2,315.00 2.000 dwl unit 4,630.00- SCI ROAD ARTERIALS C Single Family Housing 705.00 2. 0 dwl unit 11410.00- AMOUNT DUE 35,276.00 RECEIVEDTBY: t 1 l H j, 1, SIGNATURE:97 PLEASE PRINT NAME) DATE: !< to — NOTE TO RECEIVING SIGNATORY&PLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY REESUIT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1-BLDG DEPT 3-APPLICANT 2-FINANCE 4-LAND MANAGEMENT NOTE** PERSONSEDARE T THIS IATRD/REENATHESEMOLEOUYROADIRE/RESCUESTATEMENTOF ISSUANCE OF A BUILDIfiIG PERMIT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. TH9 REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE POP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. INSPECTION SEQUENCE BP# 17-876 ADDRESS: 610 W. 91h Street BUILDING PERMIT Min Max Inspection Description 10 Footer / Setback Stemwall 10 Slab / Mono Slab 20 Lintel / Tie Beam / Fill / Down Cell Sheathing — Walls 30 Sheathing — Roof 40 Roof Dry In 50 Frame 60 Insulation Rough Firewall Screw Pattern 70 Dr all / Sheetrock Lath Inspection Building Ceiling Air Barrier Insulation Roof (Com' l) Building Ceiling Grid Final Roof Final Stucco / Siding Final Insulation Final Firewall Final Door Final Window Final Utility Building Final Screen Structure Final Pool Screen Enclosure Pre -Demo Final Demo Final Single Family Residence 1000 Final Commercial — Final Commercial — Addition / Alteration Final Commercial — Change of Use Final Building (Other) ELECTRICAL PERMIT Min Max Inspection Description 10 Electric Underground 10 Footer / Slab Steel Bond Electric Ceiling Rough Electric Wall Rough 20 Electric Rough Pre -Power Final 10 Temporary Pole 1000 Electric Final BI Min Max Inspection Description Rough Plumb 10 Plumbing Underground 20 Plumbing 2"d Rough 20 Plumbing Tubset Plumbing Sewer Plumbing Grease Trap Rough Plumbing Steam / Chill Water Rough 1000 Plumbing Final MECHANICAL PERMIT Min Max Ins ection Description 10 Mechanical Rough Mechanical Fire Damper Framing Mechanical Ceiling Rough Mechanical Fire Damper Annular Space Mechanical Insulation Wrap Mechanical Fire Damper Angle Light / Water Test Ck Welds Mechanical Grease Duct Wrap 1000 Mechanical Final REVISED: June 2014 BMP INTERNATIONAL, INC. MECHANICAL UNIT STEEL TIE -DOWN CLIP: ATI GRADE & RMTOP MOUNTED APPLICATIONS 75W MIN. WEIGHT, MECHANICAL UNIT PER SEPARATE TYP. I CERTIFICATION, tCENTER OF GRAVITY ! I ''•. ASSUMED TO ACT AT THE UJ^ GEOMETRIC CENTER OF THE I I MECHANICAL UNIT. SEE DES MECHANICAL UNIT MUST BE 5 SQUARE OR RECTANGULAR, i NO IRREGULAR SHAPES. » '`' I tCENTER OF / SCHEOU 1 GRAVITY/ IAREAANIAREA PRESSUT 0 I W I 5 1 Z 5F f • (, 3' MAX TYP.., 3' P n HOST STRUCTURE DESIGN /./•'ti. BY OTHERS, SEE DESIGN SCHEDULES FOR •` ALLOWABLE SUBSTRATES ^•.` .•` i/ . „g i - 3• MAX 3• MAX( % MECHANICAL UNIT TMP'/ I N TIE -DOWN ISOMETRIC TYPE OF CLIP AND NUMBE 001 ISOMETRIC PER CORNER WILL VARY PER CONNECTION TYPES CI•C4 OP TIE -DOWN CLIP DIRECTIVE EXAMPLE THE FOLLOWING O MFIE ILLUSTMATES THE PROCEDURE USED TO DETERMINE THE MAXIMUM ALLOWABLE ROOF -TOP INSTALLATION MECHANICAL UNIT THAT OONFOR04S TO THE OIMENSION RESTRICTIONS AND DESIGN CRITERIA LISTED HEREIN. SEE SHEETS 4-5 FOR MECHANICAL UNIT CRITERIA: CONSIDER THE INSTAUATON OF (1) MECHANICAL UNIT WRIT THE FOLLOWING CRIERIA- VUR-170 MPH. EXPOSURE YT 48• TALL 48• DEEP X 48• WIDE, 100 LB (WEIGHT AS VERIFIED BY OTHERS) INSTALLED TO 3000 PSI MIN CONCRETE W ITM (t)•2' CUP AT EACH CORNER OF UNIT (TOTAL OF (4) CUPS) PROCEDURE: 00 010-0 iN FOR 0SURFACE DESIGN EEL TIE -DOWN CUPS. E DETAIL 1/3 B 2/3 R CUP INFORMATION, xT i J M, FOR ANY GIVEN SCHEDULES.) PROCEDURE STEP RESULT I DETERMINE THE CONNECTION TYPE BASED ON THE OIAGR MS ON SMEET 2 CONNECTION TYPE 3 1 2 DETERMINE WHICH DESIGN SCHEDULE TABLE TO USE THIS INSTALLATION IS INTENDED FOR A VuR-170 MPH, EXPOSURE V. THIS DESIGN CRITERIA CORRESPONDS TO TABLE 5 7 DETERMINE LARGEST FACE AREA OF MECHANICAL UNIT TO BE INSTALLED 4B•a4B•-16PT' THIS UNIT HEIGHT OF 48• IS EQUAL TO THE MA)IMUN ALLOWABLE HEIGHT OF 48•. NOTM'THIS PRODUCT APPROVAL ALLOWS THE UNIT TO BE INSTALLED ON TOP 4 CHECK MAXIMUM LINT HEIWR1lESTRICROM OF AN A/C STAND THAT IS A NAXIHUM "- TALLH. IPAN A/CSTAND 15 urruzE0, CHECK TO SEE THAT TN! STAND DOES NOT EXCEED 30-IN NEIGNT S CHECK MINIMUM UNIT WIDTH RESTRICTION UNIT WIDTH IS 4B• WHICH IS GREATER THAN THE MINIMUM ALLOWABLE WIDTH OF N• THIS UNIT MAY BE INSTALLED AT ROOF HEIGHTS LESS THAN OR EQUAL TO 15 FT. 6 DETERMINE THE ALLOWABLE ROOF -TOP HEIGHT OF THE INSTALLATION ADDITIONALLY. THIS UNIT MAY BE INSTALLED ON ROOFTOP HEIGHTS GREATER THAN 60FT AND LESS THAN l00 FT. SEE (•) ON TABLE S FOR THE NUMERICAL VALUES OF THIS DESIGN EXAMPLE DESIGN NOTES: THIS PRODUCT HAS BEEN DESIGNED IN ACCORDANCE WITH ASCE 7.10 AND THE FHA A• BUILDING 000E FOR USE WITHIN AND OVTSIOE THE HIGH VELOCITY HURRICANE 20 INDICATED IN THE ACCOMPANYING DESIGN SCHEDULES. THE DESIGN CRITERIA USED 6, FORROOFTOPEIGHTS (H) S60 Ft AND SECTION LATE THE ALLOWABLE ROOF -TOP HEIGHTS 29 9 FOR ROOFTOP HEIGHTS (HASCE 7- 10 SECTION )a60 Fl B SECTION 29.4.1 FOR INSTALLATIONS AT GRACE (GCIL..0-3.10 WITHIN THE MVHZ, GC,k_,- 1.90 OUTSIDE THE MVHZ, (GC, I.S FOR ALL LOCATIONS (CONCURRENT). ALL OTHER DESIGN VARIABLES ARE IN A ANCIE WITH ASCE 7•l0 CHAPTERS 26 B 29. THE HEIGHTS LISTED IN THE DESIGN SCHEDULES REPRESENT THE ALLOWABLE HEIGHT OF THE BUILDING. THIS PRODUCT APPROVAL ALLOWS FOR EACH UNIT TO BE INSTALLED ON A MAXIMUM 30' TALL A!C STAND (CERTIFICATION BY OTHERS) ON TOP OF THE HEIGHTS LISTED IN THE DESIGN SCHEDULES. GENERAL NOTES: 1. THIS PRODUCT HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE B ASCE 7.10. THIS PRODUCT MAY BE USED WITHIN AND OUTSIDE THE HIGH VELOCITY HURRICANE ZONE. 2. NO 33.1/3% INCREASE IN ALLOWABLE STRESS HAS BEEN USED IN THE DESIGN OF THIS SYSTEM. 3. DESIGN IS BASED ON CLIENT PROVIDED PRODUCT AND DIE SHEETS FROM TEST REPORTS #TEL 01970387A. PTEL 019703878 BY TESTING EVALUATION LABORATORIES, INC.. NO SUBSTITUTIONS WITHOUT WRITTEN APPROVAL BY THIS ENGINEER SMALL BE PERMITTED. 4. MAXIMUM B MINIMUM DIMENSIONS AND MINIMUM WEIGHT OF MECHANICAL UNIT SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. ALL MECHANICAL SPECIFICATIONS CLEAR SPACE, TONNAGE, ETC) SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. S. FASTENERS TO 6E P 12 X W OR GREATER SAE GRADE 5 UNLESS NOTED OTHERWISE TAPCONS REFERRED TO HEREIN SHALL BE ITW BURDEX BRAND, CARBON STEEL ONLY, INSTALLED TO 3000 PSI MIN CONCRETE. SEE ANCHOR SCHEDULE FOR ANCHOR REQUIREMENTS. ALL FASTENERS SMALL HAVE APPROPRIATE CORROSION PROTECTION TO PREVENT ELECTROLYSIS. 6. ALL STEEL CUPS SHALL Be ASTM A283 STEEL (GRAVE 0) WITH FY-33 KSI OR BETTER. ALL STEEL MEMBERS SMALL BE PROTECTED AGAINST CORROSION WITH AN APPROVED COAT OF PAINT, ENAMEL OR OTHER APPROVED PROTECTION. G90•RATW COATING REQUIRED FOR ALL ODASTAL INSTALLATIONS, 7. ALL CONCRETE SPECIFIED HEREIN IS NOT PART OF THIS CERTIFICATION. AS A MINIMUM, ALL CONCRETE SMALL BE STRUCTURAL OONCREM 4• MIN. THICK AND SMALL HAVE MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI, UNLESS NOTED OTHERWISE. 6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 9. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY OTHERS. 10. THE ADEQUACY OF ANY EXISTING STRUCTURE TO WITHSTAND SUPERIMPOSED LOADS SMALL BE VERIFIED BY THE ONSITE DESIGN PROFESSIONAL AND IS NOT INCLUDED IN THIS CERTFICATON. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 11. THE SYSTEM DETAILED HEREIN IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SPECIFIC SITE. FOR SITE CONDITIONS DIFFERENT FROM THE CONDITIONS DETAILED HEREIN, A LICENSED ENGINEER OR REGISTERED ARCHITECT SMALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE IN CONJUNCTION WITH THIS DOCUMENT. 12. WATER - TIGHTNESS OF OUSTING HOST SUBSTRATE SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SMALL BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. 13. FOR AN EXPLANATION OF EXPOSURE CATEGORIES THAT ACCOMPANY THE VHdt WIND SPEEDS USED IN THIS APPROVAL, SEE SECTION 26.7.3 OF ASCE 7•I0. r-I 1JZ AM OZd= p Z vi a C Lu Via• x G m 15- 2378 CONNECTION TYPE Cl Z 1' CLIP • UTILIZE (1) AT EACH COINER FOR A TOTAL OF (4) PER UNIT PC, 2 i CONNECTION TYPE C3 2' CUTS • UTTUZE (I) AT eACN CORNER FOR A TOTAL OF (I) PER UNIT gig i 3' MAX TYP. , '\ 1' CUPS 3' MA TYP. UTILIZE (2) AT EACH CORNER FOR A TOTAL OF it t; few W 3' MAX TYP. 1 2' CUPS II01111/1AI/.E ANCHOR SCHEDULE: 1" CLIPS 2" CLIPS SUBSTRATE DESCRIPTION 1)-5/16'0 CARBON STEEL ITW BUILDER TAPCON, CONCRETE: 2Y.- FULL EMBED TO 4- THICK MIN, CONCRETE, 3W MIN, 3000 PSI MIN.) EDGE DISTANCE. 31' MIN, SPACING TO ANY ADJACENT ANCHOR. AWALUMINUM: ALL I' 1}P14 SAE GRADES MIN. SHEET METAL SCREW TO THICK, 6061 AWNINUM, PROVIDE (S) NIN. ALUMINUM) MI TE5 MIN. PAST THREAD MANE STEEL: 1)-A 14 SAE GRADES 0. 12A NIN. SHEET METAL SCREW TO THICK. 33 KSI STEEL, PROVIDE (S) MIN. STEEL) PITCHES MIN. PAST THREAD PLANE SUBSTRATE DESCRIPTIOMf Jf UI ZSl t)•S/16'O CARBON CONCRETE: RW BUILDa TA COI r V..' FULL EMBED TO V THICI MIN, CONOIem 3)1- MIN. " PSI PUM.) EOGQ 3N-MIN. Wei' 1ISJACNTI3000PACING T TOANY HV a ADJACENTANCHOR. U' S m AWMIUM: 2)•0II SAE GRADES j a( Z xx paa 0. 125' MIN. SHEET METAL 9CREW5 TO W AWM( NUM, PROVIDE (S) P 52 MIN' ALUMINUM) TM p1 NE 0 W w 3J+ 08 6 I 1 STEEL: ESAE S 0.125' MIN. SCREWS SHEET ETMETALSClEWSTOTHICK, 33 KSI STEEL, PROVIDE (S) EE i MIN. STEEL) PITCHES MIN. MST V i6 THREAD MANE Z 1. EMBEDMENT AND EDGE DISTANCE EMUOES FINISHES, IF A"UCASLE. J 2. ENSUREMINIMUMEDGEDISTANCEASNOTEDINANCHORSCHEDULE. 3 3. SEE DETAILS ON SHEET 3 FOR ANCHORS ATTACHING TO MECHANICAL UNIT. Q zOmn 0O 11 1, 4Q9l: G 9 Z p4k S I UNIT WIDTH W MAX 6' MAX Lu w z rn c CLIP OFFSET CLIP PAIR CUP OFFSET E 1 SPACING IF< a I 3' TYP MECHANICAL m i CUP-CJP UNIT PER SPACING SEPARATE CERTIFICATION I E' IiISI Otl MAX'- UTILIZE ( 4) CUPS EA SIDE TYP. OF UNIT FOR A TOTAL OF I j ( 0) PER UNIT I: 3• FINf j J 1CONNECTION TYPE C4 PS • UTILIZE ( 2) AT EACH CORNER FOR A TOTAL OF (8) PER UNIT 1 ALTERNATE ( 8) CLIP DETAIL lZJ / N. T. S. PLAN VIEW THIS DETAIL MAY BE USED AS AN ALTERNATE GEOMETRIC PATTERN FOR ALL CONNECTION TYPES THAT UTILIZE (2) CUPS AT EACH CORNER FOR A TOTAL OF (8) CUPS PER UNIT. ON/ NMLLD1V100 J: I 15-2378 G NT OFSW/RONt I i ar t FOR ANY CUP LONGER THAN 10' Air UTILIZE (5)412 SAE TYP. GRADE S SHEET METAL SCREWS, TYP. 0.o66•THIQ( ASTM A283 STEEL, TYP. v 3)-112 SAE GRADE S SHEET METAL SCREWS in FOR CLIPS UP TOS-"', LONG. UTILIZE (S)-/ 12 SHEET METAL SCREWS FOR CUPS LONGER THAN r, TYP. y: 0 HOLE, WITH OANCHORFROMI' CLIP ANCHOR 0.7 SCHEDULE, TYP. onHEa DIMENSIONS SIMILAR) 1 1" CLIP ISOMETRIC DETAIL 3 N.T.S. ISOMETRIC 0.07r OR 0.113'THICK ASTM A283 STEEL, TYP. 09 fo 3)-*12 SAE GRADE S SHEET METAL SCREWS FOR CUPS 4. RANG. UTILIZESHEET MET'_A_AL SCREWSS FORSCREWS CLIPS LONGER THAN 4', TYP. WO HOLES, NOT TO BE USED FOR ANCHORS, TYP. FACTORY -MILLED Wo HOLES: y UTILIZE (1) OR (2) ANCHORS 1 mom r CUP ANCHOR SCHEDULE, TYP. 0.50' 2 2" CLIP ISOMETRIC DETAIL 3 N.T.S. ISOMETRIC MECHANICAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 6063.76 MIN. ALUMINUM SHEET WITH Fty-30 KSI, 0.125' MIN. THICKNESS, STEEL HOUSING UNITS SHALL BE ASTM AGS3 Fy-33KSI MIN. STEEL, GRADE 33, 22GA MIN. (t-0.0299-). 0.06r THICK ASTM A203 STEEL CLIP, TYP. BASE OF UNIT SMALL BE FLUSH WITH EASE OF CUP, NO SPACE PERMITTED, TYP. 3)•i12 SAE GRADE 5 SHEET METAL SCREWS FOR CLIPS UP TO S- LONG. UTILIZE (0.812 SHEET METAL SCREWS FOR CUPS LONGER THAN S% PROVIDE (5) PITCHES MIN. PAST THREAD FLARE FOR EACH SMS, TYP. ANCHOR PER ANCHOR SCHEDULE SUBSTRATE PER ANCNoa SCHEDULEF//ff i 1" TIE -DOWN CLIP 3 ANCHOR DETAIL 3 3' - 1'-0' DETAIL CUP IS DESIGNED FOR FULL CONTACT WITH THE BASE OF EACH MECHANICAL UNIT, TYP. MECHANICAL UNIT BY OTHERS. ALUMINUM HOUSING UNITS SHALL BE 6063-TG MIN. 1LUMINUM SHEET WITH Fty-30 KSI, 0.125' MIN. THICKNESS, STEEL HOUSING UNITS SHALL BE ASTM A6S3 Fy-33KSI HIM. STEEL, GRADE 13, 22GA MIN. (t-0.029V). 0.072, OR 0.113' THICK ASTM A203 STEEL CUP TYP 3)-112 SAE GRADE 5 SHEET METAL SCREWS FOR CUPS 4' LONG. UTILIZE (4)-0tZ SHEET METAL SCREWS FOR CLIPS LONGER THAN 4'. PROVIDE (5) PITCHES MIN. PAST THREAD PLANE FOR EACH SMS. TYP. BASE OF UNIT SHALL-,,, (1) OR (2)ANCHORS BE FLUSH WITH BASE/ PER 3SCHEDULE OFCUP, NO SPACE EOULE PERMITTED. TYP. SUBSTRATE PER ANCHOR SCHEDULE z ( VARIES) 2" TIE -DOWN CLIP a ANCHOR DETAIL 3 r - FIF DETAIL CUP IS DESIGNED FOR FULL CONTACT WITH THE BASE OF EACH MECHANICAL UNIT. TYP. FRANK L UNNMO0. .E 1110N11RN% Y I,,, U Z H d n j Od Q 3p Z€ 29 t N Lu 2.1 Z OZ.4 a W m artNUNLmNNmo A 1 15- 2378 a Nra oasaumorN i 5 TABLE 1: Vult=175 MPH, EXPOSURE C FOR USE WITH A RISK CATEGORY 11 STRUCTURE IN THE HIGH VELOCITY HURRICANE ZONE-) ALLOWABLE TIE CI ROOFTOP HEIGHT (NJ DOWN CONFIGURATION TYPE CZ C3 CI MAXIMUM SURFACE AREA OF UNITYLARGEST FACE UNIT HEIGHT UNIT WIDTH 6 FT' 24' MAX 12' MIN N/A AT GRADE AT GRADE H S 200 FT 9 FT' 32- MAX 15' MIN N/A AT GRADE AT GRADE H s 60 FT 4FP 46' MAX 24' MIN ATGRADE H520OFT H53OFT H5200 FT 6Fr ATGRADE H340FTDE ATGRADE HS200FT 9 FT' N/A AT GRA AT GRADE H S 16D FT 12 FT' N/A I ATGRADE ATGRADE HS40 FT 16 FT' N/A ATGRADE N/A AT GRADE 20 Fr 60' N/A MAX IB' MIN N/A AT GRADE N/A AT GRADE 25 FT' ATGRAOE H/A AT GRADE 30 FT' N/A N/A N/A AT GRADE 36Fr N/A N/A N/A ATGRADE INU IAOIiq RRMI?110V: IV OC VXV WIInIN InG nYn<WnKJI Wnlwln OKVWMV MV MULMI-CAGE COUNTIES. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPLICABILITY OF THIS TABLE WITHIN CERTAIN FLORIDACOUNTIES TABLE 3 : Vult=170 MPH, EXPOSURE C FOR USE WITH A RISK CATEGORY 0 STRUCTURE') ALLOWABLE ROOFTOP HEIGHT (H) TIE - DOWN CONFIGURATION TYPE 1 MAXIMUM SURFACEAREAOF UNIT UNIT Cl C2 C3 C4 UNITS LARGEST HEIGHT WIDTH FACE GfT' 24'MAX IT MIN N/A H5200FT ATGRADE 60FT< HS160FT HS200FT 9 FT' 32' MAX 15' MIN N/A H 5 LS FT 60FT< H5200FT. AT GRADE H S 200 FT 4 FT' AT GRACE HS200FT H5200 FT H5200 FT 4B' MAX 24'MIN 60FT< H520DFT 6 FT' ATGRADE HSZW FT HS40 FT 60FT< HS200FT HS200FT 9FT' N/A H5200FT AT GRADE 60FT4H% SOFT HS200FT 12 FT' NIA AT GRADE N/A H5200FT 60FT4H9200FT 16 FT' N/A ATGRADE N/A H5200 FT 20 FT' N/A ATGRADE N/A I H S 201D FT 25 FT' NIA N/A N/A H 5 30 FT 60' MAX IB'MIN 60 FT<H S200 FT 30 Fr N/A N/A N/A AT GRADE 60FT< HS180FT 36 Fr N/A H/A N/A AT GRADE AS AN EXAMPLE. THIS TABLE IS PERMISSIBLE TO BE USED WITHIN PALM BEA04 COUNTY. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPUCA91UTY OF THIS TABLE WITHIN CERTAIN FLORIDA COUNTIES. TABLE 2 : Vult=175 MPH, EXPOSURE D FOR USE WITH A RISK CATEGORY 11 STRUCTURE IN THE HIGH VELOCITY HURRICANE ZONE,) ALLOWABLE TIE Cl ROOFTOP HEIGHT DI) DOWN CONFIGURATION TYPE CZ C3 C4 MAXIMUM SURFACE AREA OF UNITSLARGEST FACE UNIT HEIGHT UNIT WIDTH 6 FT' 24" MAX 12' MIN N/A ATGRADE AT GRADE H s 200 FT_ 9 FT' 3Y MAX 1S' MIN N/A ATGRADE N/A H s 30 FF 4 FT' 6FT' 4M MAX 21' MIN AT GRADE H5200 FT AT GRADE Hs200 FT N/ A HS15FT ATGRADE HSIOpFT 9 FT' N/A AT GRADE ATGRADE H S BO FT 12F, N/A ATGRADE N/A ATGRADE 16 FT' N/A ATGRADE N/A ATGRADE 20 FT' 25 FT, SOFT' — 60' MAX 4B'MIN N/ A AT GRACE H/A ATGRADE N/ A N/A N/A ATGRADE N/ A N/A N/A ATGRADE is; N/A N/A N/A ATGRAOE V: Iqp rVVnlwou= IV OC V49V "Ifni" Ing nvM Wn11.11 WNINN.I0KVWAKV ANY MIAMFDAOE COUNTIES. CHECK WITH LOCAL AUTHORITY RAVING JURISDICTION FOR THE APPLICABILITY OF THIS TABLE WITHIN CERTAIN FLORIDA COUNTIES TABLE 4: Vult=170 MPH, EXPOSURE D FOR USE WITH A RISK CATEGORY II STRUCTURE-) ALLOWABLE ROOFTOP HEIGHT (NJ TIE - DOWN CONFIGURATION TYPE MAXIMUM SURFACE AREA OF UNIT UNIT CI CZ C3 C4 UNWSLARGESTHEIGHTWIDTHFACE 6 Fr 24• MAX 1Z' MIN WA H S 200 FT AT GRADE 61FT< HSBO FT H S 200 FT 9 FT' 32, MAX 1S• MIN N/A AT GRADE 6OFT< HS200FT H/A I H S 200 FT 4Fr 4B' MAX 24'MIN 60 FAT GRAD 0R HS200 FT HS200FT H3200 FT 6FT' N/A HS20DFT 6OFT< H6200FT HS200FT SIM N/A Hsls FT 60FT4ms200FT AT GRADE N/ A HS 200 FT N S 200 FT 12FrN/A AT GRADE 60 FT <H S 120 FT N/ A N/A H/A H S 40 FT 16FT' 60FT4H9200FT 20 FT' N/A AT GRADE N/A r H S 40 FT 60FT4HS200FT N/ A N/A N/A RA ATI6025FT' 6V MAX 46' MIN FT < H FT 30 FT' N/A N/A N/A AT GRADE 60 FT<HS100 FT N/ A N/A N/A ATGRADE 36FrAS AN EXAMPLE, THIS TABLE IS PERMISSIBLE TO BE USED WITHIN PALM MACH COUNTY, CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPLICABILITY OF THIS TABLE WITHIN CERTAIN FLORIDA COUNTIES. kN: 1 F ry 4` 1 1ET1f1A1ua..•E., 33U,\ CI 5fu8 omo Q¢1W E8 Niul C wwwww iiiii O 15- 2378 I NT3 I I ocscATPITONI I ar 5 4 TABLE 5 : Vult=140 MPH, EXPOSURE B FOR USE WITH A RISK CATEGORY II STRUCTURE') ALLOWABLE ROOF -TOP HEIGHT (H) TIE,OOWN CONFIGURATION TYPE MAXIMUM SURFACEAREAOF UNIT UNIT Cl C2 Ci C4 UNITS LARGEST HEIGHT WIDTH FACE 6FT' 24•MAX 12- MIN 60fT<H5120HSISFT R H5200Fr Hs2WFT HS2WFr 9FT' 32'MAX IS* MIN ATGRADE Hs2WFT NS200 FT HS2WFT 4FT' I8' MAK 2/•MIN H5200FT H9200FT HS200Fr HS200FT 6FT' H540FT 60FrcHs2WFT H52WFr HS200FT H5200FT 9FT' AT GRADE 60FT4HS80FT HS200fF H52WFT H52WFT 12 FT' ATGRADE I HS2WFT HS40FT 60FT< H5200Ff H52W FT 16 FP N/A H S 200 FT H 515 FT 60 FT<HS 100FT H S 200 FT 20 FT' WA Ns200 FT H%lSPT H5200 FT 60FT< HS180FT 25Fr' H/A HS10FT ATGRAOE H52WFT 60* MAX 48'MIN 60 FT<HS200 rT 6OFT<HSBOFT 3o F'T' N/A H 515 FT 60 FT <H 9160 FT AT GRADE H S 200 Fr 36 FT' N/A AT GRADE AT GRAOE H S 200 Fr 60FT< H980FT AS AN EKAMPLE, THESE TABLES ARE PERMISSIBLE TO BE USED WITHIN BREVARO COUNTY. CHECK WITH LOCAL AUTHORITY HAVING JURISDICTION FOR THE APPUCABILITY OF THIS TABLE WITHIN CERTAIN FLORIDA COUNRES. TABLE 7 : Vult=140 MPH, EXI FOR USE WITH A RISK CATEGORY II STRUCTURE') MAKIMUM SURFACEAREA OF UNIT UNIT Cl UNIT' SLARGEST HEIGHT WIDTH FACE 6 FT' 24' MAX 12' MIN WA 9 FT' 32' MAX 1S' MIN WA 4 F.T, H 5 40 60fr< Hs 6 R, AT GRA 48• MAX 24' MIN 6OFr< HS 9 FT' WA 12 FT' NIA 16 FT' N/A 20 FT' N/A 25 FT' N/A 60' MAX 48' MIN 30 FT' N/A 36 FT' N/A TABLE 6 : Vult=140 MPH, EXPOSURE C jWw'll" Fob USE WITH A RISK CATEGORY R STRUCTURE-) AILOWABLEROOFTOPHEIGHT( HI YIYE G TIE- 0OYVII CONFIGURATION TYPE MAXIMUM SURFACE AREA OF UNIT UNIT Cl C2 tl CAS UT UNITfGESTHEIGHTWIDTH21TA 6FT' 24•MAX 12'MIN AT GRADE HS2WFT HS2WFr HS2WFY i 10M • 9FT' 32'MAK 15'MIN W rrr nnn N/ A H12WFT HSISFT HS2WR HS200FT' HS200 FT H5200 FT HS2WFT H5200 FT FT' cm Z6FT' AT GRADE 60fr< H5180FT H5200FT HS200FT HS200FT 2» is W 3 tj ATGRAOE HS2WFT 9FT' 48MAX24•MIN Z T HS 60FF200FT HS2WFTp/yq` Owb% 0 g WA H52WFT ATGRADE 60FT4H5 OFT HS20OFT 12fT' N/A 60 fTHSISFT HS2WFT AT GRADE H52W FT 16Fr 20Fr Z WA60FT4H5200FT AT GRADE HS200FTN/A AT GRADE 60 FT<HSIIO FT AT GRADE H5200FT 25FT' 1--I 60•MAX4YMW Q N/ A AT GRADE WAHS200FT30FT' I z i O w 36 FT' N/ A AT GRADE N/A H s 30 FT al.. 60FT<H5200FT I"I J Z dn Z t U Lu ALLOWABLE ROOF-TOHEIGHT (H) M TIE -DOWN CONFIGURATION TYPE d I a tl u o0 IH52WRHS30FT60FTcHS2WFT HS2WFT 5AT n H5200 FT D 60 FT< HRS 140 FT HS200 FTFT aa Y yyak6 NSZWFT HS2WFT HS200Fr FT H520OFr HS200FTHS200FTHSIWRHslSFT 60FT<HS2WFr HS2WFF p i i i H540FT AT GRADE HS2WFTg gly 60 FT<HS200 FT 60FT< H 560 FT 1 AT GRADE 60 FT <H S2WN/ A FT HS2W FT OT' IOIirtHW41L40FIIIWI 15- 2378 AT GRADE AT GRADE 60Fr<H52WFTHS2WFT SCAIlN KTAL rAGe 095soup "I AT GRADE N/ A H 5200FT60FT<HS80Fr WA N/A HS40 FT 60Fr<HS2WFT 5 WA N/A AT GRACE 60FT< H5200FT FORM R405-2014 PERMIT # FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical End Unit Builder Name: RLH Construction Street: 610 West 9th Street Permit Office: City of Sanford City, State, Zip: Sanford, FL. 32771 OFFICE Permit Number. Owner: Typical End Unit Jurisdiction: 691500 Design Location: "FL, Orlando County:: Seminole (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (696.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 696.00 ft' b. WA R= ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. WA R= ft 5. Is this a worst case? No 10. Ceiling Types (787.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 787.00 ft 6. Conditioned floor area above grade (82) 787 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. WA R= ft' 11, Ducts R W 7. Windows(50.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor. Dbl, U=0.33 50.00 ft' SHGC: SHGC-0.27 b. U-Factor. WA ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:15.00 c. U-Factor. NIA ft' SHGC: - 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 17.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (787.0 sqft.) Insulation Area EF: 0.650 a. Slab -On -Grade Edge Insulation R=0.0 787.00 ft' b. Conservation features b..N/A.- -- - R= -ft' -- None --- -------- c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.064 Total Proposed Modified Loads: 25.97 PASSTotalBaselineLoads: 28.87 I hereby certify that the plans and specifications covered by Review of the plans and t•tuE ST42, this calculation are in compliance with the Florida Energy specifications covered by this v0 FO,p Code. dw-t't' calculation indicates compliance with the Florida Energy Code. r°N• ;;_ `a. OV PREPARED BY. _ _ _ _ _ Before construction is completed W DATE: ._._- 03-17-17 ___ _~ ,___ _ this building will be inspected for V compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. i,, C •. with the Florida Energy Code. OD WE'ta OWNER/AGENT:.._._ ..._._ ... __..--________ BUILDING OFFICIAL: DATE: _.... DATE:---- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. J 3/17/201711:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Pagel of 5 PERMIT # 17 op CORM R405-2014 OFFICE FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical Inner Unit Builder Name: RL.H Construction Street: 610 West 91h Street Permit Office: City of Sanford City, State, Zip: Sanford, FL, 32771 Permit Number. Owner: Typical Inner Unit Jurisdiction: 691500 Design Location: FL, Orlando County:: Seminole (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(448.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 448.00 ft' 3. Number of units, if multiple family 1 b. N/A c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' R= ft' 5. Is this a worst case? No 10. Ceiling Types (777.0 sgft.) Insulation Area a. Under Attic (Vented) R=38.0 777.00 ft' 6. Conditioned floor area above grade (ft') 777 b. N/A R= fta Conditioned floor area below grade (ft3) 0 c. N/A A :• R= ft' 7. Windows(40.0 sgft.) Description Area 11. Ducts a. Suit -Attic, Ret: Attic, AH: Attic R ft' 6 225 a. U-Factor. Dbl, U=0.33 40.00 ft' SHGC: SHGC=0.27 b. U-Factor: N/A fta 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:15.00 c. U-Factor: N/A ffs SHGC: d. U-Factor. N/A fe 13. Healing systems kBtu/hr Efficiency SHGC: a. i lectric Heat Pump 17.2 HSPF:8.50 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (777.0 sgft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 777.00 ft' I b. Conservation features EF: 0.650 b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.051 Total Proposed Modified Loads: 25.16 PASSTotalBaselineLoads: 26.68 I hereby certify that the plans and specifications covered by Review of the plans and VUE STgT this calculation are in compliance with the Florida Energy specifications covered by this 04 OCode. calculation indicates compliance e y ,, <. .offwiththeFloridaEnergyCode. I-* O PREPARED BY: ______. _ Before construction is completed D DATE: this building will be inspected for V y° compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. COD WTS OWNER/AGENT:__ . _.____ _. ._ _._ BUILDING OFFICIAL: DATE: .- ------ ---........ - - - -- -- DATE: --- - -- - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 17/2017 11:56 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 Project Summary Job: R0317109 wrightsofC Date: 03-17-17 Entire House By: AD Florida SPECS Inc 815 S. French Ave. Sanford. FL 32771 Phone: 407-322-0216 Project• • For: Typical Inner Unit 610 West 91h Street, Sanford, FL 32771 Notes: Load Calculation was obtained from an electronic copy of drawing. Desiqn Information Weather: Orlando Sanford, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 39 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing _ Structure 5333 Btuh Structure 7917 Btuh Ducts 1091 Btuh Ducts 3391 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 1826 BtuhPiin Equipment load 6424 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 1a134—Btuh Method Construction quality Fireplaces Simplified Average 0 Area ft Heab'ng Cooling Volume ( ft3) 6215 6215 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 63 33 Heating Equipment Summary Make Goodman or Eqv Trade Split HP Model GSZ140181K AHRI ref 8242614 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 17 OF 8. 5 HSPF 172000 Btuh @ 47°F O 0 cfm 0 cfm/Btuh 0. 50 in H2O Backup: Aux Heat Input = 5 kW, Output = 17061 Btuh, 100 AFUE Latent Cooling Equipment Load Sizing Structure 1921 Btuh Ducts 626 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 2547 Btuh Equipment total load 15681 Btuh Req. total capacity at 0.73 SHR 1.5 ton Cooling Equipment Summary Make Goodman or Eqv Trade Split HP Cond GSZ140181K Coil ASPT29614A AHRI ref 8242614 Efficiency 12.5 EER, Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 15 SEER 13140 Btuh 4860 Btuh 18000 Btuh 600 cfm 0. 053 cfm/Btuh 0. 50 in H2O 0. 84 wri ht.SOft• 2017-Mer-1711:58:52 1"' 9 Right-SuNe® universal 2017 17.0.10 RSU07440 Pape 1 MCA ...h St Apartments%RO317109Typical Inner UnH.rup Cale - MJ8 House Front faces: W b- vim9 htsoft~ Manual S Compliance Report Job: R0317109 Date: 03-17-17 Entire House By: JND Florida SPECS Inc 815 S. French Ave. Sanford. Fl. 32771 Phone: 407-322-0216 Project Information For: Typical Inner Unit 610 West 9th Street, Sanford, FL 32771 Cooling Equipment Design Conditions - Outdoor design DB: 93.0°F - Sensible gain: 13134 Btuh Outdoor design WB: 75.2°lis- Latent gain: 2547 Btuh Indoor design DB: 75.0°F Total gain: 15681 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman or Eqv Model: GSZ140181K+ASPT29B14A Actual airflow: 600 cfm Sensible capacity: 13140 Btuh 100% of load Latent capacity: 4860 Btuh 191% of load Total capacity: 18000 Btuh 115% of load SHR: 73% Heating Equipment Design Conditions design DB: 40.9°F Heat loss: 7270 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman or Eqv Model: GSZ140181K+ASPT29B14A Actual airflow: 0 cfm Output capacity: 17200 Btuh 237% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 235% of load Temp. rise. 26 OF Meets are all requirements of ACCA Manual S. Entering coil DB: 80.5°F Entering coil WB: 64.7°F Entering coil DB: 70.0°F Capacity balance: 17 OF Economic balance: -99 OF 2017-Mar-17 11:58:52wrightsoft• Right -Suite® Universal 2017 17.0.10 RSU07440 Page 14CCP% ...h St Apartments1R0317109Typical Inner Unh.rup Cale - M.18 House Front faces: W wri htsoft" Duct System Summary 03- Job: 1109 9 Date: 17-17 Entire House By: JND Florida SPECS Inc -P-.-CT PcAl.,, '4V--4oGof 815 S. French Ave. Sanford. FL 32771 Phone: 407-322-0210 PERMIT Project• • For: Typical Unit 610 West 9th Street; Sanford, FL 32771 0j:j:jCE External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.40 in H2O 0.18 in H2O 0.22 in H2O 0.140 / 0.080 in H2O jr' 0.131-, in/100ft 0- cfm Cooling 0.40 in H2O 0.18 in H2O 0.22 in H2O 0.140 / 0.080 in H2O 0.131 in/100ft 600 cfm 168 ft Supply Branch Detail Table Name Design Btuh) Htg cfm) Clg cfm) Design FIR Diam in) H x W in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath c 200 0 10 0.160 4.0 Ox 0 VIFx 17.7 70.0 st2 Bedroom c 2947 0 147 0.139 8.0 Ox 0 VIFx 21.3 80.0 st2 Khchen C 2980 0 149 0.137 8.0 Ox 0 VIFx 27.5 75.0 st3 Living Rm c 2123 0 106 0.137 7.0 t)x 0 VIFx 22.1 80.0 st2 Master Bedroom C 3355 0 167 0.131 8.0 Ox 0 VIFx 26.9 80.0 st3 Meath c 114 0 6 0.150 4.0 Ox 0 VIFx 23.7 70.0 st3 MWic C 307 0 15 0.141 4.0 Ox 0 VIFx 24.5 75.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type cfm) cfm) FIR fpm) in) in) Material Trunk st2 Peak AVF 0 263 0.137 595 9.0 0 x 0 VinlFlx st1 st3 Peak AVF 0 337 0.131 618 10.0 0 x 0 VinlFlx SO st1 Peak AVF 0 600 0.131 720 11.4 12 x 10 RectFbg I Return Branch Detail Table Name Grille Size (in) Htg cfm) Clg cfm) TEL ft) Design FIR . Veloc fpm) Diam in) H x W in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x 0 0 600 60.7 0.131 561 14.0 0x 0 VIFx 2017-Mar-20 15:48:47 y wrightsoft• Right -Suite® Universal 2017 17.0.10 RSU07440 Pape 14M ...91h St Apanments%R0317109 Typical Ford Unil.rup Cat = MJ8 House Front faces: W wrightsoR- Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave, Sanford. FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03.17-17 By: JND 3 4 5 1 Room name 2 Exposed wall Room height Room dimensions Room area Living Rm 0 ft 8.0 ft heat/cool 12.0 x 14.3 It 172.0 ft' Hall 0 ft so R heeUcool 1.0 x 322 R 37 2 rya Ty Construclnumber ion U-value BtuNfP-•F) Or HTM BIUNtti) Area or perimeter (n) B) oor perv er (ft) B) Heat I Cod Gross WP/S Heat cool Gores WP/S Heart Cod 6 1qI L-,G R L--D F 13A-Sofa 4A5-20b .- •-- 13A-5ocs 11N0 _ 0.1i5 0.330 0.125 0N 9.026 w w_ n 3.84 9.60 3.64 1018 G_;M 28.78 24t3 2378 1.56 10.87 1.42 0.00 115 20 172 172 0 -- — 0 -- 95 20 172 0 0 •-•-- 0 0 344 205 1 0 0 0 0 0 147 218 0 0 0 32----3o 0 0 0 0 — - 0 0 0 0 0 0 2 o 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 679 610 24 46 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants ® 230 Appliancestother 0 0 900 0 0 0 Subtotal (lines 6 to 13) 679 1510 24 46 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 2096 43% 0 0 4 682 140 0 0 7 Isis 650 2D% 43% 0 0 24 0 0 0 0 46 0 0 Total room load Air required (Cfm) 822 0 2166 115 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed e1C A wriphtsolR' Rlght-Sulte® Universal 2017 17.0.10 RSU07440 2017-Mar-17 11:50:52 h St Apartments%R0317109Typical Inner Una.rup Cak = MJ8 House Front faces: W Page 5 wrightsoft- Right-J® Worksheet Entire House Florida SPECS Inc 815 S French Ave. Sanford. FL 32771 Phone: 407-322-0218 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bedroom 13.9 ft 8.0 ft heal/cod 1.0 x 134.9 ft 134.9 ft' Bath 0 ry 8.0 R heWCool 87 x 5.3 It 46.2 W Ty Constriction number U-value BttdYfl{'F) Or HTM at ft.) Area (ft) or perimeter (ft) load Btuh) Area (1111 or penmeter (ft) Load Btuh) Heat Cool Gross WP/S Heat Cod Gross N/P/S Heat Cool 6 11 1pf • G R L--D C — 13A-5ocs 4AS-2cb_ - • - - - 13A-50cs 11N0 18B-38ad_. -•-- •-- 0.125 0330 0.125 0.350 0.026 w vy_ n 3.64 9,80 3.64 10.18 0.78 2.48 23 :78 1.56 10.87 42 112 20 88 0 135 92 2 a8 130 395 192 920 0 102 401---- 0-- 228 476 137 0 191 t) 0 43 0 U 0 43 0 46 0 0 155 0 35 0 0 0 66 0 66 0 48 14_ 6 c) AED excursion 323 0 Envelope loss/gain 1349 1355 190 132 12 a) Infiltration b) Room ventilation 1116 0 382 0 0 0 0 0 13 Intemal gains: Occupants ® 230 Appliances/ other 1 230 0 0 0 0 Subtotal ( lines 6 to 13) 2465 1947 190 132 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 2M 43% 0 0 8 2473 508 0 0 355 2302 986 2096 0396 0 0 6 196 40 0 0 11 143 61 Total room load Air required (Um) 2979 0 3288 174 235 0 204 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A&- 44- wrightSarr Right -Suite® Universal 2017 17.0.10 RSU07440 2017-Mar-17 11.58.52 h St ApertmentslR0317109Typical Inner UnR.rup Calc - MJ8 House Front faces: W Page 4 wrightsoR- Right-lO Worksheet Entire House Florida SPECS Inc 815 S. French Ave. Sanford, FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Kitchen 0 " 8.0 It hea0/cod 13.3 x 123 ft 164.4 IN Landry 0 It 0 ft heat/cool 3.0 x 2.7 ft 8.0 no Ty ionConstruction U-value 8100L-F) Or HTM Btutwts) Area (W) or perimeter (ft) Load at Area (ft) or perimeter (fU Load Btuh) Heat Cod Gross N/P/s Heat cool Gross N/P/s Heat Cod 6 11 VVppII G PII -- D C__, F _ _ 13A-5ocs — ---- 4A5-2ob , . _ _ _ 13A-5ocs 11N0 i6B-38ad_„_ _,_•,— 0.125-w 0.330 0.125 0.026 0.989 w 3.64 9.80 364 10.18 0.76 28.78 248--.0_.0_..-- 23.78 1.56 10_87 1,42 0.00 0 0 0 184 164 0 0 0 164 0--------0 0 0 0 124 0 0 0 0 0 0 p 0 0 b p 0 00 0 6 c) AED excursion 0 0 Envelope loss/gain 124 233 6 11 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants ® 230 Appliances/other 0 0 150D 0 0 500 Subtotal (lines 6 to 13) 124 1733 6 511 14 15 Less external load Less transfer Redistribution Subtotal Duct toads 2016 43% 0 0 0 124 25 0 0 0 1733 742 2016 43% 0 0 6 0 0 0 0 511 0 0 Total room load Air required (dim) 150 0 2476 131 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i86, wrights4aft- Right -Suite® Universal 2017 17.0.10 RSU07440 2017-Mar-17 HP.58: e 3hStApartmenta1R0317109TypicalInnerUnit.rup Calc - We House From faces: W wrightsoft- Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave, Sanford, FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room cbmensions Room else Mwic 0 It 8.0 ft heal/cod 4.7 x 5.7 ft 25.4 ft' Mbath 0 ft 8.0 it he0Uc001 8.7 x 5.7 ft 49.1 ft' Ty CorkstW number asr U-VwBtWVRue F) Or Btwtta) or perimeter (ft) atrfi) or periArea meter (ft) Load at Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 11 V" 13A-50C3 R 0 C-..- 4A5; 20b-- --__ 13A- 5003 11N0 -•-•— _ JOB- 38ad •_- 27Acpl 0. 125 0. 330 0. 125 0, 35o 0. 026 0. 989 w w n 3. 64 9. 00 354 10. 18 O jB 248 23. 78 1. 56 10. 87 0 0 0 0 0 0-__.__.... 0---- 0 0 0 0 0 0 0 0 0 38 0 D- 0 0 49 0 0 0 0 49 0 0 0 0 37 0 0 0 0 0 1,42 28 2t3 20 0 6 c) AED excursion 0 0 Envelope Wss/ga^ 20 38 37 70 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants ® 230 Applia= s other 0 0 0 0 0 0 Subtotal ( lines 6 to 13) 20 38 37 70 14 15 ILess eta Wed Less transfer Redistribution Subtotal Duct Weds 20% 43% 0 0 0 20 4 0 0 0 38 16 20% 43% 0 0 6 43 9 0 0 12 81 35 Total room Wad Air required (cfm) 200 520 1166 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightSOft' Right-SuNeO Universal 2017 17.0.10 RSU07440 2017-Mar-17 11:58:52 A86` ... h St Apenmerts%R0317109T Page 2 Typical Inner UnN.rup Cak a MJ8 House Front feces: W wrightsoft- Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave, Sanford, FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Roan narne Exposed wall Room height Roan dimensions Room area Entire House Master Bedroom 25.3 ft 11.3 ft 0 It d 8.0 ftheal/ood 11.3 x 12 7 ft 776.9 W 143.6 ft" Ty Construction number U-value Btu1Vft'-'F) Or HTM B1utYft Area or perimeter (IQ AreaBtu) a penmeter (ft) B) Heat Cod Gross WP/S Heat Cod Gross WP/S Heat Cod 6 11 t P C__ F 13A-Sots 4AS2d) --• _ 13A-5ocs 11N0— 189-38ad, _ 22ACpl _ - -- 0.125 0.330 0.125 0.350 0.026 0.989 w vv n 3 80 8.60 3.64 10.18 0.78 28.78 2.48_ 23.70 1.56 10.87 1 42 0.00 203 40 245 20 777 777 163 5 225 2p 777 25 582 384 819 205 588 77.7 404 91 951 _-_ 20 351 0 218 _ 0 1102 _ 144 144 7i 2 0 0 257 192 0 0 175 476 0 0 204144109 6 c) AED excursion 646 323 Envelope loss/gain 3314 3672 MW 1178 12 a) infiltration b) Roan ventilation 2018 0 655 0 1 903 0 293 0 13 internal gains: Occupants a 230 Appliances/olher 3 690 2 2900 480 0 Subtotal (lines 6 to 13) 5333 7917 1787 1931 14 15 Less external load Less transfer Redistribution Subtotal Duct beds 2096 43% 0 0 0 5333 1091 0 0 0 7917 3391 2096 43% 0 0 7 1794 367 0 0 173 2103 901 Total room load Air regtured (dm) 6424 0 11308 600 2161 0 3004159159 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsOft- Right-SuileO Universal 2017 17.0.10 RSU07440 2017-Mar-17 11:58:52 h St Apartments%R0317109Typical Inner Unrt.rup Cale - MJ8 House Front faces: W Pape 1 wrightsoft, Project Summary Entire House Florida SPECS Inc 815 S. French Ave. Sanford. FL 32771 Phone: 407-322-0216 Project Information For: Typical Inner Unit 610 West 9th Street, Sanford, FL 32771 Job: R0317109 Date: 03-17-17 By: AD Notes: Load Calculation was obtained from an electronic copy of drawing. Design Information Weather: Orlando Sanford, FL, US Winter Design Conditions Outside db 41 OF Inside db 70 OF Design TD 29 OF Heating Summary Structure Ducts Central vent (0 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces Summer Design Conditidns Outside db 93 OF Inside db 75 OF Design TD 18 OF Daily range M Relative humidity 50 Moisture difference 39 gr/lb Sensible Cooling Equipment.Load Sizing 5333 Btuh Structure 1091 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh 6424 Btuh Use manufacturer's data Rate/swing multiplier Equipment sensible load Simplified Average 0 Area ft Heab'n Cooling Volume (ft3) 6277175 6215 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 63 33 Heating Equipment Summary Make Goodman or Eqv Trade Split HP Model GSZ140181K AHRI ref 8242614 Efficiency 8.5 HSPF Heating input Heating output 17200 Btuh @ 47°F Temperature rise 0 F Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 17 OF Backup: Aux Heat Input = 5 kW, Output = 17061 Btuh, 100 AFUE 7917 Btuh 3391 Btuh 0 Btuh 1826 Btuh 1.00 I 13134 Btuh Latent Cooling Equipment Load Sizing Structure 1921 Btuh Ducts 626 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 2547 Btuh Equipment total load 15681 Btuh Req. total capacity at 0.73 SHR 1.5 ton Cooling Equipment Summary Make Goodman or Eqv Trade Split HP Cond GSZ140181K Coil ASPT29B14A AHRI ref 8242614 Efficiency 12.5 EER, 15 SEER Sensible cooling 13140 Btuh Latent cooling 4860 Btuh Total cooling 18000 Btuh. Actual air flow 600 cfm Air flow factor 0.053 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Mer-17 11:58.52wrighttSOft* Right -Suite® Untversal 2017 17.0.10 RSU07440 Page 1 h St Apartmems1R0317109Typical Inner Unit rup Cale - MJ8 House From feces: W wrightSofC Manual S Compliance Report Job: R0317109 Date: 03-17-17 Entire House By: JND Florida SPECS Inc 815 S. French Ave. Sanford. FL 32771 Phone: e07-372-0216 Project• • For: Typical Inner Unit 610 West 9th Street, Sanford, FL 32771 Cooling Equipment Design Conditions V Outdoor design DB: 93.0°F Sensible gain: 13134 Btuh Entering coil DB: , - 80.5°F Oxidoor design WB: 75.2°F Latent gain: 2547 Btuh Entering coil WR.- 64XF Indoor design DB: 75.0°F Total gain: 15681 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturers Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman or Eqv Actual airflow: 600 cfm Sensible capacity: 13140 Btuh Latent capacity: 4860 Btuh Total capacity: 18000 Btuh Model: GSZ140181K+ASPT29814A 1000/9 of load 191 % of load 115% of load SHR: 73% Heating Equipment Design Conditions Outdoor design DB: 40.9°F Heat loss: 7270 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Goodman or Eqv Model: GSZ140181K+ASPT29B14A Actual airflow: 0 cfm Output capacity: 17200 Btuh 237% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 235% of load Temp. rise: 26 OF Meets are all requirements of ACCA Manual S. Entering coil DB: 70.0°F Capacity balance: 17 OF Economic balance: -99 OF 2017-Mar-17 11:58:52 C + wrightSoft' Right -Suns® Universal 2017 17.0.10 RSU07Ae0 Page 1 h St Apenments1R0317109 Typical Inner Unn.rup Calc . MJB House Fran laces: W FORM R405-2014 ENERGY PERFORMANCE LEVEL EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 610 West 9th Street, Sanford, FL, 32771 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 448.00 fta b. N/A 3. Number of units, if multiple family 1 c, N/A R= fta R= Its 4. Number of Bedrooms 2 d. N/A R= fta 5. Is this a worst case? No 10. Ceiling Types a. Under Attic (Vented) Insulation Area R=38.0 777.00 ft' 6. Conditioned floor area (ft3) 777 b. N/A R= fta c. N/A7. Windows" Description Area R= rta Ductsa. U-Factor. Dbl, U=0.33 40.00 Its a. a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 225SHGC: SHGC=0.27 b. U-Factor. N/A fta SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A fta a. Central Unit 18.0 SEERA5.00 SHGC: d. U-Factor. N/A ffa SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.333 ft. a. Electric Heat Pump 17.2 HSPF:8.50 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14. Hot water systems a a. Electrica. Slab -On -Grade Edge Insulation R=0.0 777.00 Its 1 gallons b. N/A R= fta EF: 0.65 c. NIA R= fta b. Conservation features None 15. Credits None certify that this home has complied with the Florida Energy Efficiency Code for Building onstruction through the above energy saving features which will be installed (or exceeded) SHE sr ATFonthishomebeforefinalinspection. Otherwise, a new EPL Display Card will be completed oF = i r , ased on installed Code compliant features. y i• , 3uilder Signature: 9 Date: ddress of New Home: City/FL Zip: WE,'' Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/17/2017 11:56 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 I M R405-2014 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan HeatinJan Venting Jan Feb fX Feb Feb Mar X Mar Mar l_ A r Apr Ma May X Jun Jun Jul Jul X Au Aug X Se Sep X Oct Oct Nov Nov Dec Dec Xlx] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ( WD) AM PM 78 -- 80 78 80 78 80 78 - 80 78 78 78 78 78 78 78 _ 78 80 78 80 78 80 78 80 78 Cooling ( WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM808080807878787878787878Heating ( WD) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating ( WEH) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 N 3/ 17/2017 11:56 AM EnergyGaugel) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Omt ID Frame Panes NFRC U_-Factor SHGC _ Area Depth Separation Int Shade Screening 1 W 1 TIM Low-E Double Yes 0.33 0.27 20.0 ft' 1 ft 4 in 0 ft 6 in Drapes/Winds Exterior 5 2 W 2 TIM Low-E Double Yes 0.33 0.27 20.0 ft° 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000254 518.2 28.45 53.5 .1856 5 HEATING SYSTEM System Type -- Subtype _ _ - Efficiency _ Capacity Block_ Ducts _ 1 Electric -Heat Pump Split HSPF:8.5 17.2 kBtu/hr 1 sys#1 COOLING SYSTEM System Type _ Subtype-- - - —` Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 18 kBtu/hr 600 cfrn 0.73 1 sys#1 HOT WATER SYSTEM System Type SubType Location_ - EF - -- Cap Use SetPnt - Conservation 1 Electric Tankless Mwic 0.65 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name - --- A System Model # Collector Motlel # Area FEF None None Volume f' DUCTS Supply — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 225 ftAttic 150 ft' Default Leakage Attic (Default) (Default) 3/17/2017 11:56 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 FLOORS Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Living Rm 1 ft 0 173 ft' 0 0 1 9 Slab -On -Grade Edge Insulatio Hall t ft 0 32 ft' 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 842 ft' 162 W Medium 0.65 No 0.9 No 0 22.6 ATTIC V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 777 ft' N N Y • CEILING Ceiling Type - - _ Space - R-Value Ins Type _ Area Framing Frac- - Truss Type -_ 1 Under Attic (Vented) Master Bedroom 38 Blown 144 W 0.1 Wood 2 Under Attic (Vented) Mwic 38 Blown 26 ft' 0.1 Wood 3 Under Attic (Vented) Mbath 38 Blown 49 ft' 0.1 Wood 4 Under Attic(Vented) Kitchen 38 Blown 164 ft' 0.1 Wood 5 Under Attic (Vented) Laundry 38 Blown 8 ft' 0.1 Wood 6 Under Attic (Vented) Bedroom 38 Blown 135 ft' 0.1 Wood 7 Under Attic (Vented) Bath 38 Blown 46 ft' 0.1 Wood 8 Under Attic (Vented) I Living Rm 38 Blown 173 W 0.1 Wood 9 Under Attic (Vented) Hall 38 Blown 32 ft' 0.1 Wood WALLS Adjacent SpaceCavity Width Height Sheathing Framing Solar Below Omt......-. To---Waft Type.-_ .—_.--R-Value-..-Ft-in- Ft-- Jn_ .._.-Area--- R,Value-_Fraction--Absor.-Grade% 1 W Exterior Concrete Block - Ext Intdbster Bedro 5 11 4 8 0 90.7 ft' 0 0 0.3 0 2 W Exterior Concrete Block - Ext InsuBedroom 5 14 0 8 0 112.0 ft' 0 0 0.3 0 3 N Exterior Concrete Block - Ext InsuBedroom 5 11 8 88.0 ft' 0 0 0.01 0 4 N Exterior Concrete Block - Ext Insul Bath 5 5 4 8 42.7 ft' 0 0 0.01 0 5 N Exterior Concrete Block - Ext InsuLiving Rm 5 14 4 8 114.7 ft' 0 0 0.01 0 DOORS Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Living Rm None 46 3 6 8 20 ft' 3/ 17/2017 11:56 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 PROJECT Title: R0317109 Typical Inner Unit Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 777 Lot 0 Owner. Typical Inner Unit Total Stories: 1 Block/SubDivision: 0 of Units: 1 Worst Case: No PlatBook: Builder Name: RLH Construction Rotate Angle: 0 Street: 610 West 9th Street Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford , Family Type: Single-family FL, 32771 New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp VV-_ - Design Location --- TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Orlando FL ORLANDO INTL_AR 2 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume V-------•-----• 1 Entire House 777 6216 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated_ 1 Master Bedroom 144 1152 No 2 1 1 Yes Yes Yes v I.%F V Tes Yes Yes 3 Mbath 49 392 No 0 1 Yes Yes Yes 4 Kitchen 164 1312 Yes 0 1 Yes Yes Yes 5 Laundry 8 64 No 0 1 Yes Yes Yes 6 Bedroom 135 1080 No 1 1 1 Yes Yes Yes 7 Bath 46 370 No 0 1 Yes Yes Yes 8 Living Rm 173 1384 No 0 1 Yes Yes Yes 9 Hall 32 256 No 0 1 Yes Yes Yes FLOORS 0 _ Floor Type -- - Space Perimeter Perimeter R-Value 0 Area 1 Slab -On -Grade Edge Insulatio Master Bedroom 11.3 ft 144 ft 2 Slab -On -Grade Edge Insulatio Mwic 1 ft 0 26 W 3 Slab -On -Grade Edge Insulatio Mbath 1 It 0 49 ft' 4 Slab -On -Grade Edge Insulatio Kitchen 1 It 0 164 ft' 5 Slab -On -Grade Edge Insulatio Laundry t It 0 8 Its 6 Slab -On -Grade Edge Insulatio Bedroom 13.9 ft 0 135 ft' 7 Slab -On -Grade Edge Insulatio Bath 1 ft 0 46 W Joist R-Value - --Tile Wood Carpet -- 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 3/17/2017 11:56 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical Inner Unit Builder Name: RLH Construction Street: 610 West 91h Street Permit Office: City of Sanford City, State, Zip: Sanford, FL. 32771 Permit Number. Owner: Typical Inner Unit Jurisdiction: 691500 Design Location: FL, Orlando . .. County:: Seminole (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(448.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ent Insul, Exterior R=5.0 448.00 ft' 3. Number of units, if multiple family 1 b. N/A c. N/A R= ft' R= ft' 4. Number of Bedrooms 2 d. N/A. R= ft., 5. Is this a worst case? No 10. Ceiling Types (777.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 777.00 ft 6. Conditioned floor area above grade (ft') 777 b. N/A R= ft' Conditioned floor area below grade (ft2)*4' 0 • c. R 7. Windows(40.0 sqft.) Description- Area 11 t.sDucts a. Sup: Attic, Ret: Attic, AH: Attic R ft' 6 225 a. U-Factor: Dbl, U=0.33 40.00 ft' SHGC: SHGC=0.27 b. U-Factor: N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:15.00 c. U-Factor. N/A ft' SHGC: ^ 13. Heating systems kBtu/hr Efficiencyd. U-Factor. N/A ' fta. Electric Heat Pump 17.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (777.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 777.00 ft' b. Conservation features i EF: 0.650 b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/ Floor Area: 0.051 Total Proposed Modified Loads: 25.16 PASS TotalBaselineLoads: 26.68 1 hereby certify that the plans and specifications covered by Review of the plans and STg2 this calculation are in compliance with the Florida -Energy specifications covered by this 0- V% Code. calculation indicates compliance 0 withtheFloridaEnergyCode. f+N„•.. ?.`:' PREPARED BY: _._ __ _ Before construction is completed DATE: ....... _-__ 03-17-17 _ _ _ _- this building will be inspected for o Ili compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance the Florida Energy Florida Statutes. Cpp withCode. WE OWNER/ AGENT: ____.-_..__. _...__._ BUILDING OFFICIAL: __ DATE: ._ -- - -- . .. --- DATE: -- -- - -- ------ Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/ 17/2017 11:56 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 Manual S Compliance Report Job: R0317109 Wrightsoft" Date: 03-17-17 Entire House By: JND Florida SPECS Inc 815 S. French Ave, Sanford, FL 32771 Phone: 407-322-0216 Project Information For: Typical End Unit 610 West 91h Street, Sanford, FL 32771 Cooling Equipment Design Conditions Outdoor design DB: 93.0°F Sensible gain: 13135 Btuh Entering coil DB: 79.4°F Outdoor design WB: 75.2°F Latent gain: 2567 Btuh Entering coil WB: 64.3°F Indoor design DB: 75.0°F Total gain: 15702 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Manufacturer: Actual airflow: Sensible capacity: Latent capacity: Total capacity: Split ASHP Goodman or Eqv- 600 cfm 13140 Btuh 4860 Btuh 18000 Btuh Model: GSZ140181K+ASPT29B14A 1001/6 of load 189% of load 1150/6 of load SHR: 730/6 Heating Equipment Design Outdoor design DB: 40.9°F Heat loss: 9209 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH Manufacturer: Goodman or Eqv Model: GSZ140181K+ASPT29B14A Actual airflow: 0 cfm Output capacity: 17200 Btuh 187% of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 0 cfm Output capacity: 5.0 kW 185% of load Temp. rise: 26 OF Meets are all requirements of ACCA Manual S. Entering coil DB: 70.0°F Capacity balance: 23 OF Economic balance: -99 OF 1 wrightsoft' Right -Suite® Universal 2017 17.0.10 RSU07440 2017-Mar-17 09 Page I Typical End.rup Cak MJB House Front feces: WAC& ...10 W 9Ih St Apartments%R0317109T Pepe wrightsoft Project Summary Entire House Florida SPECS Inc 815 S. French Ave. Sanford. Fl. 32771 Phone: 407-322.0216 Job: R0317109 Date: 03-17-17 By: JND For: Typical End Unit 610 West 9th Street, Sanford, FL 32771 Notes: Load Calculation was obtained from an electronic copy of drawing. Weather: Orlando Sanford, FL, US Winter Design Conditions Summer Design Conditions Outside db • 41 OF Outside db 93 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 39 gr/lb Heating Summary. Structure 7221 Ducts 1106 Central vent (0 cfm) 0 Humidification 0 Piping 0 Equipment load 8327 Infiltration Method Construction quality Fireplaces Sensible Cooling Equipment Load Sizing Btuh Structure 8591 Btuh Btuh Ducts 3435 Btuh Btuh Central vent (0 cfm) 0 Btuh Btuh Blower 1109 Btuh Btuh y Btuh Use manufacturer's data Rate/swing multiplier 1.00 Equipment sensible load 13135 Btuh Simplified Average 0 Area (W)Heatl8g Cool 07 Volume (ft3) 6297 6297 Air changes/hour 0.61 0.32 Equiv. AVF (cfm) 64 34 Heating Equipment Summary Make Goodman or Eqv Trade Split HP Model GSZ140181 K AHRI ref 8242614 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 23 OF 8.5 HSPF 172000 Btuh @ 47°F O 0 cfm 0 cfm/Btuh 0.50 in H2O Backup: Aux Heat Input = 5 kW, Output = 17061 Btuh, 100 AFUE Latent Cooling Equipment Load Sizing Structure 1932 Btuh Ducts 634 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 2567 Btuh Equipment total load 15702 Btuh Req. total capacity at 0.73 SHR 1.5 ton Cooling Equipment Summary Make Goodman or Eqv Trade Split HP Cond GSZ140181K Coil ASPT29614A AHRI ref 8242614 Efficiency 12.5 EER, 15 SEER Sensible cooling 13140 Btuh Latent cooling 4860 Btuh Total cooling 18000 Btuh Actual air flow 600 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Mar-17 09:39:55 c wrightsoft- RIpM-Suite® Universal 2017 17.0.10 RSU07440 page 1 10 W 91h St Apartments%RO317109Typical End. rup Cal MJ8 House Front faces: W wrightsoR, Right-JO Worksheet Entire House Florida SPECS Inc 815 S. French A", Sanford. FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room dinw%sroris Room area Entire House 56.3 ft 8.0 It d 787.1 H' Master Bedroo n 24.3 It 8.0 ft heaVcod 11.7 x IV ft 147.8 f s Ty construction U-value BtutWtl;-F) Or HTM Btuwnv) And (118) or perimeter (ft) Load Btuh) Area (ft) or perimeter (ft) Load Btuh) Heat Cod Gross WP/S Heat cool Gross N/P/S Heat cool 6 11 t_- L-G 1q1 R D c _ F ... 13A-5ocs - - 4A5 lob 13A-5ocs _ N 5lob -_-- 13A-5ocs 11N0 -- - ._- _ 16B-38ad 22A p1 _ -•- -- 0.125 0.330 0.125 0 330 s s- w w 3.54 9.80 3.64 246 9.20 248 23.78 1.56 10.87. 1.42 0.00 245 0 205 40 235 10 165 5 225 20 787 58 856 96 601 384 819 205 596. 1619 584 92 410 951 351 218 1116 0 101 0 93 20 0 0 148 146 91 10 79 2 332 96 257 192 0 112 99 227 92 182 476 0 0 210 0.12$ 0.350 0.026 0989 n- 9.60 3.64 10.16 0.76 28.7t1 245 20 707 787 0 0..--0 148 24 6 c) AED excursion 615 292 Envelope loss/gain 5176 4338 1699 1478 12 a) Infiltration b) Room ventilation 2045 0 664 0 883 0 287 0 13 Internal gains: Occupants ® 230 Appliances/other 3 690 29W 2 460 0 Subtotal pines 6 to 13) 7221 ew 2583 2224 14 15 Less external load Less transfer Redstribution Subtotal Dud loads 15% 4016 0 0 0 7221 11W 0 0 0 8591 3435 15% Q% 0 0 0 2583 3% 0 0 0 2=4 869 Total room load Air regrored (dm) I a= 1 0 12025 600 1 2978 1 0 3114 155 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. c Wrf ht1s011't- 2017-Mar-17 09,39:55 9 Right-Suile® Universal 2p17 17.0.10 RSU07440 Page 1 10 W 91h St Apartments%R0317109Typical End.rup Cak - M.18 House Front faces: W wrightsoft• Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave, Sanford, FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room dmensions Room area Mwic 5.7 ft 8.0 It heal/cool 0 x 5.7 ft 28.3 Its Mbath 0 ft 8.0 It heal/Cool 8.7 x 5.7 ft 49.1 fts Ty Constriction number U-value BtuWf 2-'F) Or HTM BtuWfts) Area (ft') or perimeter (ft) Load Stuh) Area (W) or perimeter (11) Load Btuh) Heat Cool Gross NIPIS meet Cod Gross WPIS Heat Cool 6 11 t--1: tQl G P L-D C _ 130k-5ocs -- - - 4A5.2ob.-- -•---- • 13A-5ocs 4AS2ob-----•- 13A-5ocs 168-38ad _ 0.125 0.330 0.125 0 330 0.125 0.350 0.026 0.989 a s-_ w w • n.. 3.64 9.60 3.64 9.60 3.64 10.18 0.78 2B.78 248 9.20 2.48 23.78 1.58 10.87 1 42 0.00 45 0 45 0 0 9 0 0 28 8 165 0 0 0 112 0 0 0 0 9 0 0 9 0 0 0 0 0 0 0 0 0 0 0 0 28 28 0 0 21 163 0 0 40 0 0 0 0 49 49 0 0 49 0 0 0 37 0 0 70 0 6 c) AED excursion 0 0 Envelope loss/gain 349 153 37 70 12 a) Infiltration b) Room ventilation 206 0 67 0 0 0 0 0 13 Internal gains: Occupants ® 230 ApploxxWolher 0 0 0 0 0 0 Subtotal (lines 6 to 13) 555 219 37 70 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 15% 40% 0 0 0 555 85 0 0 0 219 88 15% 40% 0 0 0 37 6 0 0 0 70 28 Total morn load Air required (cfm) I 640 ol 307 151 1 43 0 98 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 55 I.K - FId- WrightSOft`t- Right-SudsO Univemel 2017 17.0.10 RSU07440 2017-Mar-17 0Page 2 10 W 91h St Apanments1R0317109Typical End.rup Calc a M.18 House Front faces: W wrightsoft, Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave. Sanford. FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND I 2 3 4 5 Room narne Exposed wall Room height Roan dimensions Room area Kitchen I2.3 It 8.1) ft hwVcoci 13.7 x 12.3 ft 168.6 11112 Law" 0 " 8.0 ft heat/cool 3.0 x Z7 ft 0 "1 Ty Constniction munber U-value BtuWft-'F) Or HTM B1uNftI Area (tt') or penmeter (ft) Load Btuh) Area (ft) or perimeter (ft) Load Stuh) Heal Cool Gross WP/S Heal cool Gross N/P/S Heat cool 6 11 G 1L- 0 R c- 13A-5= 5 20b—_. 13A-5ocs 13A-5ocs 0.125 0.330 0.125 0.125 9.025 s k. w w-- 3.64 9.60 3.64 9.0 Z48 9.20 248 23. 99 0 99 0 0 359 o 0 245 o 0 0 0,__ 0 0 0 0 0 Q 0 P 0 0, 0 0 0 0 0 3.64 6 1.56 0 169 0 0 128.. 355 0 239 0 0 0 11169 2 8 8 6. 6 c) AED excursion 0 0 Envekve loss/gain 841 484 6 11 12 a) Infiltration b) Room ventilation 448 0 145 01 00 1 0 0 13 Internal gains: Occupants a 230 Appliances/ other 0 0 1500 0 0 500 Subtotal ( lines 6 to 13) 1289 2129 6 511 14 151 Less external load Less transfer Redistribution SLOlotal Duct loads 15% 40% 0 0 0 1289 197 0 0 0 2129 851 15%1 40% 0 0 0 6 1 0 0 0 511 204 T( Aal room loeid Air regained (drn) 1487 0 22980 149 7 01716 31 jCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. Old- wrightSaft' Right-SufteV Universal 2017 17.0.10 RSU07440 2017-Mar09:39:55 A105k ... 10 W 91h St Apartments%R0317109 Typ"I End. rup Cale - WO House Front faces: W Page 3 wrightsoR• Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave• Samford. FL 32771 Phone. 407-322-0216 Job: R0317109 Date: 03-17-17 By: JND 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bedrpom 13.9 ft 8.0 1t heWCool 1.0 x 134 9 ft 134.9 Its Bath 0 ft 8.0 ft heeVood 8.7 x 5.3 ft 46.2 its Ty Canstnidion number U-value BtuNfts---F) Or HTM Btwfts) Area (fts) or perimeter (ft) Load Btuh) Area (ft') or perimeter (ft) Load Btuh) Heat Cod Gross N/P/S Heat Cod Gross WP/S Heat Cod 6 11 f- G R - 1—p C-- F 130k-5ocs - 4A572ob 13A-5ocs - 13A-5ocs 11N0--. 16B_3880----- 22°! •- - - - 0.125 0.330 0125 0.330 0.125 0.350 s s w w n 3.64 9.60 364 9 60 3,64 10.18 076 28.78 7.48 9.20. 7-48 23.78 1.56 10.87.. 142 0.00 0 0 112 20 86 0 j35 135 0 0. 92 2 86 0 135 14 0 G 335 192 320 0 102 491 0 o 226 137 0 191 0 0 0 0 0 0 0 43 0 46 G 0 0 0 155 0 35 U 0 U 0 66 0 66 0 43'- 0 46. 0 A.026 0.989 6 c) AED excursion 323 0 Envelope bsWgain 1349 1355 190 132 12 a) Infiltration b) Room ventilation 508 0 165 0 0 0 0 0 13 Intemal gains: Octuparts ® 230 Appliances/olher 1 230 0 0 0 0 Subtotal pines 6 to 13) law 1750 190 132 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 1 15% 40% 0 0 0 1858 285 0 0 0 1750 700 15% 40% 0 0 0 190 29 0 0 0 132 53 Total room bad Air required (elm) 2142 0 2450 122 219 0 185 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htt50ft' 2017-Mar-17 09:39:55 Right Universal 2017 17.0.10 RSU07440 Popp 4 10 W 91h St AponmemstR0317/09 Typical End rup Cale - MJ8 House Front faces: W wrightsoft Right-M Worksheet Entire House Florida SPECS Inc 815 S. French Ave, Sanford, FL 32771 Phone: 407-322-0216 Job: R0317109 Date: 03.17-17 By: JND 1 2 3 4 5 Roan name Exposed wall Room height Room dimensions Roan area Living Rm O ft 0 ft heat/Cool 120 x 14.3 ft 177 0 ft' Hall O ft 8.0 ft heal/cod 10 x 372 ft 37-2 ft' Ty Constriction number U-value BtutVfti'F) Or Hw at 3) Area (W) or perimeter (ft) Load Stuh) Area (fts) or perimeter (ft) Load Stuh) Heat Caul Gross WP/S Heat Cod Gross WP/S Heat Cod 6 11 134-5ocs — — 4A520b----- 13A-5ocs 4AS20b--,—•__ 13A-5oCs 11N0---.--_ 16B-38ad.--- •-•-- 22&-cpl —. 0.125 0.330._s. 0.125 0_330 0.125 0.350 0 025 0.989 s- w w • n- 3.64 9-80--9.20----.0-- 3.64 9.60 3.64 10.18 0.76 28.78 2.48 Z48 23.78 1.56 10.67 1.42 O.QO 0 0 0 115 20 172 172 0 0 0 0 95 M 172 P 0 0---•0----- 0 0 344 205 130 0 0 0 147 218 244 0 0 0 0 0 0 0 32 0 0 0 0._— 0 0 0 0 0 0 0 0 0 0 46 0 1qJ R D C- - F —_ 0 0 32, 0..-- 0 0 24 6 c) AED excursion 0 0 Envelope loss/gain 679 610 24 46 12 a) Intimation b) Room ventilation 0 0 0 0 0 0 0 0 13 Intemal gains: Occupants a 230 Applenceslother 0 0 900 0 0 0 Subtotal (limes 6 to 13) 679 1510 24 46 14 15 Less external load Less transfer Redrstnbution SLOolal Duct loads 1596 4096 0 0 0 679 104 0 0 0 1510 604 15% 40%1 0 0 0 24 4 0 0 0 46 18 Total room load Air required (cfm) 783 01 2113 105 28 01 64 3 Calculations approved by ACCA to meet all requirements of Manual J Sth Ed. wrightS4aft- Right -Suite® Universal 2017 17.0.10 RSU07440 2017-Mar-17 0 Page 5 10 W 91h St Apartments%R0317109Typical End.rup Cak - M.18 House Front feces. W FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical End Unit Builder Name: RLH Construction Street: 610 West 9th Street Permit Office: City of Sanford City, State, Zip: Sanford. FL. 32771 Permit Number: Owner: Typical End Unit Jurisdiction: 691500 Design Location: FL, Orlando County:: SeminoletFlorida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (696.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 696.00 W b. WA R= ft 3. Number of units, if multiple family 1 c. N/A R= fN 4. Number of Bedrooms 2 d. N/A R= fta 10. Ceiling Types (787.0 sqft.) • Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 787.00 ft 6. Conditioned floor area above grade 787 b. N/A R= ft' Conditioned floor area below grade (ft 0 c. F• R= ft R fta 7. Windows(50.0 sqft.) Description Area 11. Duuctct s a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor. Dbl, U=0.33 50.00 ft' SHGC: SHGC=0.27 b. U-Factor. NIA ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:15.00 c. U-Factor: N/A ft: SHGC: 13. Heating systems r - kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 17.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (787.0 sqft.) Insulation Area EF: 0.650 a. Slab -On -Grade Edge Insulation R=0.0 787.00 fP b. Conservation features b. N/A R= ft' None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.064 Total Proposed Modified Loads: 25.97 PASS Total Baseline Loads: 28.87 1 hereby certify that the plans and specifications covered by Review of the plans and 0' 11M SrtT4. this calculation are in compliance the Florida Energy specifications covered by this j/ with Code. 4.1/' calculation indicates compliance with the Florida Energy Code. y • 1 z q••• ' t . O PREPARED BY. _ _ ___ _ _ _ _ DATE: ________-03-17_17_-_ _ Before construction is completed this building will be inspected for vi > compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. CODwiththeFloridaEnergyCode. wt' OWNER/AGENT: _._____ _._ .. __..__ -____ BUILDING OFFICIAL: DATE: _ - -. - --- - DATE: -- ---- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/17/2017 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: R0317109 Typical End Unit Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 787 Lot # Owner. Typical End Unit Total Stories: 1 BlockJSubDivision: of Units: 1 Worst Case: No PlatBook: Builder Name: RLH Construction Rotate Angle: 0 Street: 610 West 9th Street Permit Office: City of Sanford Cross Ventilation: No County: Seminole Jurisdiction: 691500 Whole House Fan: No City, State, Zip: Sanford, Family Type: Single-family FL. 32771 New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Orlando FL ORLANDO INTL AR 2 41 91 70 75 526 44 Medium BLOCKS Number Name Area Volume 1 Entire House 787 6296 SPACES Number -- Name Area Volume Kitchen Occupants Bedrooms InN ID Finished Cooled Heated 1 Master Bedroom 148 1184 No 2 1 1 Yes Yes Yes 2 Mwic 28 224 No 0 1 Yes Yes Yes 3 4 Mbath 49 392 No 0 1 Yes Yes ' Yes 4 (Kitchen 169 1352 Yes 0 1 Yes Yes Yes 5 Laundry 8 64 No 0 1 Yes Yes Yes 6 Bedroom 135 1080 No 1 1 1 Yes Yes Yes 7 Bath 46 368 No 0 1 Yes Yes Yes 8 Living Rm 172 1376 No 0 1 Yes Yes Yes 9 Hall 32 256 No 0 1 Yes Yes Yes FLOORS Floor Type Space_ Perimeter PerimeterR_Value JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bedroom 24.3 ft — 0 Area 146 ft' 0 0 1 2 Slab -On -Grade Edge Insulatio Mwic 5.7 ft 0 28 ft' 0 0 1 3 Slab -On -Grade Edge Insulatio Mbath 1 ft 0 49 fe 0 0 1 4 Slab -On -Grade Edge Insulatio Kitchen 12.3 ft 0 169 ft' 0 0 1 5 Slab -On -Grade Edge Insulatio Laundry 1 ft 0 8 ft 0 0 1 6 Slab -On -Grade Edge Insulatio Bedroom 13.9 ft 0 135 ft' 0 0 1 7 Slab -On -Grade Edge Insulatio Bath 1 ft 0 46 ft' 0 0 1 3/17/2017 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS Floor Type Space _ Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio Living Rm 1 It 0 172 ft' 0 0 1 9 Slab -On -Grade Edge Insulatio Hall 1 It 0 32 ft' 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested• Tested Insul. deg) 1 Gable or Shed Composition shingles 852 W 164 ft' Medium 0.65 No 0.9 No 0 22.6 ATTIC Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 787 ft' N N CEILING Ceiling Type Space _ _ R_-Value_ Ins Type_ Area Framing Frac Truss Type 1 Under Attic (Vented) Master Bedroom 38 Blown 148 W 0.1 Wood 2 Under Attic (Vented) MMc 38 Blown 28 ft' 0.1 Wood 3 Under Attic (Vented) Mbath 38 Blown 49 ft' 0.1 0.1 Wood 4 Under Attic (Vented) Kitchen 38 Blown 169 ft' Wood 5 Under Attic (Vented) Laundry 38 Blown 8 ft' 0.1 Wood 6 Under Attic (Vented) Bedroom 38 Blown 135 ft' 0.1 Wood 7 Under Attic (Vented) Bath 38 Blown 46 ft' 0.1 Wood 8 Under Attic (Vented) Living Rm 38 Blown 172 ft' 0.1 Wood 9 Under Attic (Vented) Hall 38 Blown 32 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below V ._#_ Ornt To Wall Type. Space. R-Value _ Ft. In . _ Ft_ In Area — R-Value .Fraction_ Absor...Grade% 1 S Exterior Concrete Block - Ext Inldhster Bedro 5 12 8 8 0 101.3 ft' 0 0 0.3 0 2 W Exterior Concrete Block - Ext Inld6ster Bedro 5 11 8 8 0 93.3 ft' 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Mwic 5 5 8 8 0 45.3 ft' 0 0 0.3 0 4 S Exterior Concrete Block - Ext Insul Kitchen 5 12 4 8 0 98.7 ft' 0 0 0.3 0 5 W Exterior Concrete Block - Ext InsuBedroom 5 14 0 8 0 112.0 ft' 0 0 0.3 0 6 N Exterior Concrete Block - Ext InsuBedroom 5 11 8 88.0 ft' 0 0 0.01 0 7 N Exterior Concrete Block - Ext Insul Bath 5 5 4 8 42.7 ft' 0 0 0.01 0 8 N Exterior Concrete Block - Ext InsuLiving Rm 5 14 4 8 114.7 ft' 0 0 0.01 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Living Rm None 46 3 6 8 20 ft' 3/17/2017 11:36 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. WallV Overhang Omt - ID Frame ---Panes NFRC U-Factor SHGC _ Area Depth Separation Int Shade Screening 1 S 1 TIM , Low-E Double Yes 0.33 0.27 10.0 ft' 1 ft 4 in 0 ft6 in Drapes/blinds Exterior 5 2 W 2 TIM Low-E Double Yes 0.33 0.27 20.0 ft' 1 ft 4 in 0 ft6 in Drapes/blinds Exterior 5 3 W 5 TIM Low-E Double Yes 0.33 0.27 20.0 fV 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 INFILTRATION Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) - 000254 524.7 _ 28.8 — 54.17 1855 - 5 HEATING SYSTEM System Type _ Subtype Efficiency -+- Capacity _- - Block Ducts 1 Electric Heat Pump Split HSPF:8.5 17.2 kBtu/hr 1 sys#1 COOLING SYSTEM System Type _ Subtype Efficiency - Capacity Air Flow SHR Block Ducts _ 1 Central Unit Split SEER: 15 18 kBtu/hr 600 cfm 0.73 1 sys#1 HOT WATER SYSTEM System Type SubType Location Use SetPnt Conservation- 1 Electric Tankless Mwic EF _ _Cap - - 0.65 1 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC I Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None -..-----_ ...... ft' -- DUCTS Supply - Return - Air CFM 25 CFM25 HVAC # Location R- Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 225 ft' Attic 150 ft' Default Leakage Attic (Default) (Default) 1 1 3/17/ 2017 11:36 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 I•VKM K4U5-ZU14 TEMPERATURES Programablje Ceiling Fans: Heatinglin Thermosta[[t: jjN X] Jan X] Feb jj r X] Mar Apr Apr M junayI r] Aug ri Sep X Oct Nov W Dec Venting Jan Feb XJJ Mar Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 76- 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/17/2017 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. 610 West 9th Street, Sanford, FL, 32771 1. New construction or existing New (From Plans) 9. Wall Types 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior b. N/A 3. Number of units, if multiple family 1 c. N/A 4. Number of Bedrooms 2 d. N/A 10. Ceiling Types 5. Is this a worst case?- No a. Under Attic (Vented) 6. Conditioned floor area (ft) . 787 b. N/A J. c. 7. Windows" Description Area NIA a. U-Factor. Dbl, U=0.33 50.00 ft' Ducts11 a. Sup: Attic, Ret: Attic, AH: Attic SHGC: SHGC=0.27 b. U-Factor. N/A ft' SHGC: 12. Cooling systems c. U-Factor. N/A ft' a. Central Unit SHGC: d. U-Factor. N/A fe 13. Heating systems SHGC: a. Electric Heat Pump Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 787.00 ft' a. Electric b. N/A R= ft' b. Conservation features c. N/A R= None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: _ City/FL Zip: Insulation R=5.0 R= R= R= Insulation R=38.0 R= R= Area 696.00 ft' It' fe ft Area 787.00 ft' ft' f R ft' 6 225 kBtu/hr Efficiency 18.0 SEER:15.00 kBtu/hr Efficiency 17.2 HSPF:8.50 Cap: 1 gallons EF: 0.65 None O-(UE sr42: COD WE Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/17/2017 11:36 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 N HVAC Layout Typical Job#: R0317109 Performed by J N D for: Typical Unit 610 West 9th Street Sanford, FL 32771 Florida SPECS Inc 815 S. french Ave Sanford, FL 32771 Phone: 407-322-0216 Scale:1 : 38 Page 1 RightSuite® Universal 2017 17.0.10 RSU07440 2017-Wr-2015:50:38 tSIR0317109 Typical End Unil.rup N HVAC Layout Typical Job#: R0317109 Performed by J N D for: Typical Unit 610 West 9th Street S anfard, FL 32771 Florida SPECS Inc 815 S. French Ave Sanford, FL 32771 Phone: 407-322-0216 Scale:1 : 38 Pape 1 RightSuile® Universal 2017 17.0.10 RSU07440 2017adar-2015:50:38 ts1R0317109 Typical End Unit.nip 1/2814015 Florida Building Code Online Business •Professional Regulation ra= florW DeparpWtd BCIS Home I Log In I User Registration Hot Topics Submit Surcharge I Slats is Facts Publications I FBC Staff BCIS Site Map I Links Search i Busines . l al Product ApprovalProfessiUSER: Public User PERMIT Regulation Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL17676-RI UT r' Revision 2014 Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. MI Windows and Doors 650 West Market Street Gratz, PA 17030 717) 365-3300 Ext 2560 bsitlinger@miwd.com Brent Sitlinger bsitlinger@miwd.com Windows Single Hung Certification Mark or Listing American Architectural Manufacturers Association Steven M. Urich, PE Validation Checklist - Hardcopy Received Standard AAMA/WDMA/CSA 101/I.S.2/A440 Method 1 Option A 07/14/2015 07/14/2015 07/23/2015 Year 2008 hNm:llOoridabtAlding.orgtprlpr_app dU.aspx?param=wGEVXCIwtDgvFGYZsjrZFR6fG1oOf5hOzkrKelOkRkLlv7RvdmK8e.q%3d%3d 114 7/28/2015 Florida Building Code Online Summary of Products FL # Model, Number or Name Description 17676.1 3540 SH 36x74 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 Rl C CAC APC 3540 Fin 36x74.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/12/2017 Design Pressure: +35/-50 Installation Instructions Other: LC-PG35. Units must be glazed in accordance with FL17676 R1 If Install - 3540 SH 36 x74 Fin.Ddf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.2 3540 SH 36x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 Fin 36x84.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2020 Design Pressure: +40/-50 Installation Instructions Other: LC-PG40. Units must be glazed in accordance with FL17676 R1 II Install - 3540 SH Fin 36x84 Ddf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.3 3540 SH 40x66 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 Fin 40x66 Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/26/2016 Design Pressure: +35/-45 Installation Instructions Other. R-PG35. Units must be glazed in accordance with FL17676 RI 11 Install - 3540 SH Fin 40x66 Ddf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.4 13540 SH 4063 Fin Frame Limits of use Certification Agency Certificate Approved for use in HVHZ: No F117676 R1 C CAC APC 3540 Fin 44x63 Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/26/2020 Design Pressure: +40/-47 Installation Instructions Other. R-PG40. Units must be glazed in accordance with FL17676 R1 II Install - 3540 SH Fin 4063 Ddf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.5 3540 SH 4072 Fin Frame Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17676 R1 C CAC APC 3540 Fin 4072 Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/O1/2017 Design Pressure: +35/-47 Installation Instructions Other: R-PG35. Units must be glazed in accordance with FL17676 RI I1 Install - 3540 SH Fin aaY» pdf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.6 3540 SH 4084 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 Rl C CAC APC 3540 Fin 44x84.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/12/2017 Design Pressure: +30/-30 Installation Instructions Other: LC-PG30. Units must be glazed in accordance with FL17676 RI II Install - 3540 SH Fin 44x84 Ddf ASTM E1300-04. Verified By: American Architectural Manufacturers Association https://Roridabt ilding.orgtpr/pr ppp dU.aspx?param=wGE\rAQwtDgvFGYZsjrZFR6fGlo0fSWzkrKelOkRkLlv7ftvdmK8eg%3d%3d 2/4 Validator / Operations Administrator) MI Windows & Doors, LLC P.O. Box 370 Gratz, PA 17030-0370 Attn: Rick Sawdey AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION EMMA The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests, and the reporting to the Administrator of the results of tests, accompanied by related drawings, by an AAMA Accredited Laboratory. 1. The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTEDAAMA/WDMA/CSA 101/I.S. 2/A440-08 LC-PG3W-911 x1867 (36x74)-H Negative Design Pressure = -50 psf COMPANY AND CODE CPD NO. SERIES MODEL & PRODUCT MAXIMUM SIZE TESTEDDESCRIPTION MI Windows & Doors, LLC 3540 SH (FIN) FRAME SASH Code: MTL 11355 PVC)(O/X)(IG)(INS GL) 911 mm x 1867 mm 860 mm x 919 mm REINF)(TILT)(ASTM) 3'0" x 6'2") 2'10" x 3'0") 2. This Certification will expire April 12, 2017 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Architectural Testing, Inc. Report No.: C7327.01-109-47 Date of Report: May 7, 2013 Date: September 3, 2013 Cc: AAMA JGS ACP-04 (Rev. 1 /11) Validated for Certification hl 4aL oci ted Laboratories, Inc. Authorized for Certification American Architectural Manufacturers Association ELEVATION 2' typ. I d 36• J12' o.e' I mox. 2' typ. TT 12' o.o. max. L_ r n Apt*. ALL FE Ea VHICH FLASF BY GTH AnChof See Section De, a Min Edge 7/16' SHEATHING 17 JAMB DETAIL HEAD- DETAIL IZE HEADER AS NEEDED CAULK UNDER HAILING FIN QNYIgE PERIMETER BEFORE FASTENING. SHIM AS REQUIRED MUST ACHIEVE 11--1/4SSHOWNPENETRATIOVATHN • SHEATHING) INTO STUD.s SILL DETAIL Notes: 1. Installation depicted based off of structural test report /C7327.01-109-47. 2. Wood screws ahog satisfy the National Design Specification for Wood Construction for material type and dimensional requirements. 3. Wood buck installations arc assumed 2x S—P—F (G=0.42) or denser. Buck width shall be greater than the window frame Width. Tapered or partial width tucks are not allowed. Wood buck shall be secured to the structure to resist oil design foods. 4. Wood screw lengths shall be sufficient to back guarantee 1-1/4' penetration into wood 5. Maximum shim thickness of 1/4' permitted at each fastener location. Shims shall be load bearing, non— oompr ssible type. 6. These drawings depict the details necessary to meet structural load requirements. They do not address the air infiltration, water penetration, intrusion or thermal performance requirements of the installation. 7. Installation shown is that of the test window for the size shown and the design pressure claimed. For window sizes smaller than shown, locate fasteners approx. 2' from comers and no more than If on center. Design pressures of smaller window sizes ore limited to that of the test window. S ZE AND OESIgr PRESSUOW FASUM TYPE AND SPACING SHOWN Wall ALLOW DESIGN PESII O UP TO +35/ —50 UMS UP TO 36" x 74' SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS) M nc INSTALLATION INSTRUCTIONS d FASTENER SCHEDULE — FIN— aow90 cow V. M.R. 12-14-09 e Windows & Doors 3540 Single Hung NONE I 1 Gratz, PA a „ o am 3540- 3240 SH FIN — 15 ' Florida Building Code Online Business •ProfessionalRegulation nor& Nparl[Mtj BCIS Home I Log In I User Reg,stration I Hot Topics I submit Surcharge Scats 8 Facts Pubbcations FBC Staff i SCIS Site Map I Links Search I Busines 01 i Ill *USER: product ApprovalProfessiPublicUserRegulationnircl ProductAoorovalMenu > Prodrrt or Application Searc!+ > Application List > Application Detail CE+cti 4 FL # FL12194-RI Application Type Revision Code Version 2010 PERMIT # (7- F 74 Application Status Approved Comments Archived Product Manufacturer Aluminum Coils, Inc. Address/ Phone/Email 5001 West Knox Street Tampa, FL 33634 813) 249-9743 grahman@aluminumcoilsinc. com Authorized Signature Gareth Rahman grahman@aluminumcoilsinc. com Technical Representative Address/ Phone/Emall Quality Assurance Representative Address/ Phone/Email Category Panel Walls Subcategory Soffits Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert J. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity PFS Corporation Quality Assurance Contract Expiration Date 12/31/2015 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of independence FL12194 R1 COI Trinity ERD Cl - Nieminen odf Referenced Standard and Year (of Standard) Standard Year AAMA 1402 1986 ASTM E330 2002 Equivalence of Product Standards Certified By Sections from the Code hhps:/ NloridabLdlding.org/pr/pr app dU.aspx?param=wGEVXQwtDquk24AUC%21EHMrNrkL4bysAliaTZZ%2fJiuPbVxGF%21D57kxp%3d%3d 1/2 7Q2WW15 , Florida Building Code Onlinei Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved Date Revised Surnmary of Products 12/15/2011 12/16/2011 12/22/2011 01/31/2012 06/26/2015 FL # Model, Number or Name Description 12194.1 Alumunum Coils Aluminum Soffit Aluminum soffit panels Limits of Use Installation Instructions Approved for use in HVHZ: No FL12194 RI II Al er121311FINAL ALUMINUM Approved for use outside HVHZ: Yes COILS FL12194-Rl.Ddf Impact Resistant: N/A FL12194 Rl 11 A2 er121311FINAL ALUMINUM Design Pressure: +48/-64.2 COILS FL12194-RI.Ddf Other. The design pressure noted herein relates to a specific Verified By: Robert Nieminen PE-59166 installation of the 16" x 12" panel. Refer to the ER Appendix Created by Independent Third Party: Yes for design pressures of other panels / attachments. Evaluation Reports FU2194 Rl AE er121311FINAL ALUMINUM COILS FL12194 RI.odf Created by Independent Third Party: Yes Da,, N-71 Contact :: 1940 North Monroe Street Tallahassee Fl. 32M Phone: 850-407-1824 The State of Florida is an AA/EEO employer, Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessimity Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronicmailtothisentity. Instead, contact the office by phone or by traditional mad. It you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emall address If they haveone. The smalls Provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply aPeWilliaddress, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455. F.S., please dick h=. Product Approval Accepts: 1 Credit CArt1 SAFE https:llfloridabL ildirg.orglprlpr ppp ol.aspx?param=wGEVXOwtDquk24AUC`Yo2(EHMrNrkL4bysAUaTZZ%2fJiuPbVxGF%2fD57kxg%3d%3d 212 18' BLANK 3 / 8 PROFILE 0 740" IN 0 238" F' CHANNEL (3/8-) ALUMINUM 0.016511 nominal thickness Exterior Research and Design, LLC. d/b/a TrinitylERD Certificate of Authorization #9503 Robert Nieminen, PE-59166 M125 IYP. QOTRINITYIERD 2.625 REF. 50 TYR D DODDD DDOOD DDDDDDN DDDDD m D 0 0 0 0 0 D D D D D VAN LQLWM DARFOu r e I UL h IOLNM FORMED IN Sew[ DIRECTION AS Wes) Evaluation Report A13360.02.09-R3 for FL32194-R1 Aluminum Coils, Inc. Revision 1: 12/13/2011 Appendix 1, Page 1 of 2 rTRINITYIERD Exterior Research and Design, LLC. d/b/a TrinitylERD Evaluation Report A13360.02.09-R1 for FL12194-R1 Certificate of Authorization ri9So3 Aluminum Coils, Inc. Robert Nieminen, PE-59166 Revision 1: 12/13/2011 Appendix 1, Page 2 of 2 1 COUNTY OF SEMINOLE IMPACT FEE STATEMENT STATEMENT NUMBER: 17100003 1 -_"_-.'• - DATE: September 26, 2017 BUILDING APPLICATION #: 17-10000318'•_., BUILDING PERMIT NUMBER: 17-10000318 L{ Iq9,7 0O SEP262017RUNIT ADDRESS: &.9TH ST 610- 25-19-30-SAG-1009-0060 TRAFFIC ZONE:022 JURISDICTION-:-- y SEC: TWP: RNG: SUF: PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: COASTLINE APARTMENTS LLC ADDRESS: 815 S FRENCH AVE SANFORD FL 32771 LAND USE: DEMO 4 SFR REBUILD APT BLDG TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 610 W. 9TH ST / DEMO 4 1989 SFR'S / REBUILD 16 UNIT APT BLDG FEE BENEFIT RATE UNIT CALC UNIT TOTAL DUE TYPE DIST SCHED RATE UNITS TYPE ROADS- ARTERIALS Apartment* ROADS - COLLECTORS Apartment* FIRE RESCUE LIBRARY Appartment* SCHOOLS PAwrtment * LAW ENFORCE DRAINAGE CO - WIDE ORD N/ A N/ A CO - WIDE ORD CO - WIDE ORD N/ A N/ A N/ A CREDIT FEES: SCI LIBRARY C Single Family Housing SCI SCHOOLS R Single Family Housing SCI ROAD ARTERIALS C Single Family Housing 435. 00 00 54. 00 2, 100.00 54. 00 16. 000 dwl unit 16. 000 dwl unit 16. 000 dwl unit 16. 000 dwl unit 4. 000 dwl unit 2, 315.00 4.000 dwl unit 705. 00 4.000 dwl unit AMOUNT DUE 6, 960.00 00 00 864. 00 33, 600.00 00 00 00 216. 00- 9, 260.00- 2, 820.00- 29, 128.00 STATEMENT RECEIVED BY: SIGNATURE: PLEASE PRINT NAME) DATE: 7 NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1-BLDG DEPT 3-APPLICANT 2- FINANCE 4-LAND MANAGEMENT NOTE** PERSONS ARE ADVISED THAT T IS IS A STATEMENT OF FEE "DUE ER THE SEMINOLE COUNTY ROAD, FIRE RESCUE, LIBRARY AND/OR EDUCATIONAL ISSUANCE OF A BUILDING PE IT. PERSONS ARE ALSO ADVISED THAT ANY RIGHTS OF THE APPLICANT, OR OWNER, TO APPEAL THE CALCULATION OF ANY OF THE ABOVE MENTIONED IMPACT FEES MUST BE EXERCISED BY FILING A WRITTEN REQUEST WITHIN 45 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE BUT NOT LATER THAN CERTIFICATE OF OCCUPANCY OR OCCUPANCY. TH REQUEST FOR REVIEW MUST MEET THE REQUIREMENTS OF THE COUNTY LAND DEVELOPMENT CODE. COPIES OF RULES GOVERNING APPEALS MAY BE PICKED UP OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE 170P LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. Sjj LA , V h THERMAITRU 0 THERMA TRU DOORS I IS INDYST111AL DO.. 9001MON. ON 43517 Smooth -Star" and "Benchmark by Therma-Tru" m 6'8' SINGLE AND DOUBLE OPAQUE OR GLAZED PANELS W/ & W/OUT SIDELITES INSWING / OUTSWING INSULATED FIBERGLASS DOOR WITH WOOD FRAMES General Notes 1. This tit onchoring drawing has been developed in ccrnplionce with the 20101aoaido Bulding Code (FBC) excluding the Ugh Velocity HL-Cone IOale-. See the Certification Agency Certificate far sizes. specifications and Mtir% 105M MAX. OVERALL MAW WIDTH 1 2 3 3 3 3 Kt Kt s T 2 3 4 s 3 6 8 B 6 B ti DOUBLE W/ SrtTE M oxxo MAX DESIGN PRESSURE S5.0 -55.0 2. Product anchors shoo be as fated and spiced as shown on detok Anchor embedment to base material shall be beyond wad dressing, stucco, foam, brick and other wag cove+k+fs• 37-W MAX 3. Wood screws shall be installed fdbw hg Installation instructions of ANSU AFdPA NDS 2ODS, I-I I OVERALL WIDTH AD other fastener types to be installed following fastener manufacturers installation Instructions 4. Fastener embedment depths, edge distances and center -center distances shall be as specified by the fastener monufocturer but in no Instance stall they be less than shown in this drown. 3 1 1 1 1 e _" S. Where shims are used they must be a 1i fyd / sfit7' matw d Ih of corroes with the 3 a requirements of the 2DIO FBC. rr I b. Positive and negative design pressure requirements for use with this drawing shag be detemdned by others for spedfic jobs In accordance with the governing code. 7. Site conditions not covered by this drawing are subject to further engineering analysis. TAf1IE OFCONIENTS SHEEP 0 DE CRIP11oN I Typicol elmlion design pressures & general notes 2 Buek oncho" 3 korne 4 Frame orscto" d b®of materials Hortroritco 6 vertical cross secom 6 Vertical emu sections SINGLE x MAX DESIGN PRESSURE 67.0 -67.0 74-V MAX OVERALL WIDTH t 3 3 3 3 DOUBLE xx MAX DESIGN PRESSURE S5.0 -55.0 6&W MAX. eOVERALL WIDTH ee-1123 3 3 5 SWCLE W/ SIDWrES Oxo MAX DESIGN PRESSURE 40.0 -40.0 S3W MAX. OVERALL WIDTH 1 2 3 I s 3 K KA T ; L _4 it SWGLE W/Swaa Ox MAX DESIGN PRESSURE 40.0 -40.0 tOCr HARDWARE AM 4 SERIES RW KSETSIGNATURE SERIES LATCH RWIXSETt1G1uNRe SERIES M DMDSOIT uoz o E avw 3A8300., 1a Cr MASONRY OPENING 2X BUCK 4" 4" I 48" 1, I 6 „ p II 7.4 II WON IIp SHOWN FORSHOWN p MULLIONJ TYP. II REFERENCE p SHOWN FOR f I HEAD REFERENCE II do JAMBS II SEE NOTE 1 p II p II II II II ASTRAGAL II II p SHOWN FOR II II REFERENCE II II G II II p II f MASONRY J OPENING 2X BUCK U a2 p o 4 1 1 1-4. II I II MULLION 4 II SHOWN FOR TYP II REFERENCE HEAD I I JAMBS SEE NOTE 1 II II II II II II II MASONRY OPENING 2X BUCK mZCdo i mlmr t I I I I) MULLION I I 4 II SHOWN FORTyp. II II REFERENCE II HEADII II JAMBS II SEE NOTE 1 II II II I MULLION I I SHOWN FOR I I II REFERENCE II II II b— 4; rf4- NOTES:14. t. 1/4" Hco Concrete screws anchoring 2x buck require 0 minimum 1"clearance to mosorvy edges, 0 1.1/4"minimum t ' p embedment and o minimum 4" clearance to odpcent e 4 p concrete screws. Substitution of equol concrete screws from o 4 MASONRY q different supplier moy hove different edge dstonce and MASONRY OPENING TYP• HEAD IA center dstoncerequirements. Concrete screw locotbmofthe OPENING TYP• HEAD JAMBS lll ASTRAGAL, comer;, of mullion tocotbm, and of oskogol locolions moy be do JAMBS SEE NOTE 1 p SHOWN FOR odlusted to mointain the minimum edge dstonce to mortor SEE NOTE 1 2X BUCK p REFERENCE joints. It concrete screw locolions noted as MAX. ON CENTEIr p must be 0CMIed to mointoin the minimum edge distance to rx morfor joints, odd ibnof concrete screws may be required to enwre the mmdmum on center dimension is not exceeded. 2X BUCK n p p p LU 2. 2X buck min. S.G. 2 0.55. o p 0 fs N. T.S. JK rr. LFS w xoa 15225. 5-68 2 of _rL 1 ro -E" 3" C• 63FF—i Fes- 3" I I I I — MULLION nl11° SHOWN FOR ;; 11 REFERENCE A W/2X BUCK INSTALLATION OC o 9 W/1X BUCK INSTALLATION a TYP. HEAD R JAMBS SEE NOTE I — SEE NOTE 1 w nl ns nl 18 C• •D E• VIEW C'-"C' SINGLE DOOR W SIDELITES i^ Kh. ly IN PAIRS C' 3 TYP. v 3. T aoSEEDETAIL4SEE= 4' o I an\DN u' EE OTE 1 1 6. 1 1 VIEW 'E"-'E' VIEW 'D'-b" 90M r// WWM4. OORRWGA= FAsnM3¢ IMm /so fhP. Au. Smeuiz To DOOR A"cmaynow) NOTES: 1. 1/4" IIW concrete screws anchoring from& and/or sir require o minirrwm 2.1/2' clearance to masonry edges, a I.1/1` mk*rwm embedment and a minimum 3' clearance to adjacent concrete screws. Substitution of equal concrete screws from a different supplier may have different edge distance and center distonce requirements. Concrete screw locotions at the Comm, and of mullion locolions, may be adjusted to maintain the minimum edge distance to mortar joints. If concrete screw locations noted as MAX. ON CENTER" must be ad)usted to maintain fhe mum edge distance to mortorjoints, additional concrete screws may be required to ensure the maximum on center dimension is not exceeded. 2. 3/ 16• ITW concrete screws anchoring from& and/or sill require a minimum 2-5$ clearance to masonry edges, a 1-1/1' minimum embedment and a minimum 2-1/I' clearance to adjacent concrete screws unless otherwise rioted by concrete screw manufacturer. 3. The sidefle is direct set Into the jamb with (12) #8 x 2' pfh. wood screws. There are (4) at each vertical jamb, from the top down at 13.S*. 31' 48.5' & 66. There ore (2) at the header of 1' from the outside comers of the hams. There are (2) of the si0 4' from the outside comers. d• For optional sidelite construction with staples, sldeGfe Is direct set into the jamb with (I) 7/i X t?/ i 16 go. staples along each jamb (6' from ends and equoly spaced thereafter). a A. ems L I t t` N i MULLION SHOWN FOR _ o REFERENCE. IW/ 2X BUCK INSTALLATION M1 Ch W/ IX BUCK INSTALLATION oU TYP. HEAD k IAMBS Zp SEENOTE1SEE NOTE 1 in 16 n w — SEE DETAIL 72' ro• A' SINGLE DOOR W SIDELITE VIEW 'B"-'B' W/ 2X BUCK 2 INSTALLATION W/ 1X BUCK INSTAL. L4TIO 12 1 C SEE NOTE t t DETAIL " 1' N - I y1 of tsn( N x W/ 2X BUCK v INSTALLATIONu S w/ 1x BUCK — c4 INSTALLATION TYP. BSHEAD R GE SL JAM SEE NOTE 1 —11 SEE NOTE 1 0 16 SEE J$ DETAIL ' 1 . p \ pa 5 n + p m r' I G V A' SINGLE DOOR VIEW A'- A' W/ 2X BUCK 2 INSTALLATION W/ 1X BUCK 11 INSTALLATION SEE NOTE 2 DETAIL ' 2" W. JK ° Dr.- LFS ; w° co,: ° 15225. 5-68 3 or 6 C c' VIEW C"—'C' E" faINn$N 6PAIRS 30 > 3" 3 3' YN I I F 1 fn\] SEE NOTE 3I A W/2X BUCK I -T SHEET3SEEDETAIL '3"INSTALLATION I ASTRAGALS I MULLION SHOWN FOR I SHOWN FOR REFERENCE I REFERENCE ONLY I SEE NOTE 1 16 I SHEET 3 I 16 5 p s I 1 E' DOUBLE DOOR W/SIDELIIES W/ 1X BUCK y INSTALLATION TYP. HEAD x NOTE a SEEBS1SHEET 3 SEE DETAIL ' 4' 16 wa o I c; N 12 EE NOTE 1 SHEET3L T v VIEW E.—"E• 9MW W/ WW94L CO MxAIM rASMA ; MW /w OW Au Waff TO WM Are oawO=M) Item DESCRIPTION Moteriol A 10 x 2-19- PFH WOOD SCREW STEEL B f0 X 1-3 4 PFH W000 SCREW STEEL C 10 X 1 PFH WOOD SCREW STEEL 1 10 x 3 4 LG. PFH WOOD SCREW Hine to Frame I'SSTEEL10 x 2 LG. PFH WOOD SCREW STEEL 3 x 2-112' LG. PFH WOOD SCREW STEEL 4 1 4" x 2-3 4 PFH ELCO CONCRETE SCREW STEEL 5 1 4 x 1-3 4 ITW PFH CONCRETE SCREW STEEL 9 1 4 x 3-3 4 ITW PFH CONCRETE SCREW STEEL 11 3 16 x 3-1 4 ITW PFH CONCRETE SCREW STEEL 12 1 4 x 3-1 4 ITW PFH CONCRETE SCREW STEEL 13 MASONRY - 3. 192 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 16 1 4 X 2-1 4 PFH IX CONCRETE SCREW STEEL 20 HEADER JAMB 4.656 X 1.25 THERMA-TRU SUGAR PINE SG >= 0.34 W000 21 3 4 THK. PRESSURE TREATED SIDELITE PAD WOOD 30 1 2 X 1 X 25 GA. CORRUGATED FASTENER STEEL a W/2X BUCK 2 INSTALLATION A" 3" r 6. 3' T--IHF I I SEE DETAIL Yy/ 2X BUCK A 3' INSTALLATION W/1X BUCK 9 INSTALLATION o V ASTRAGAL, SHOWN FOR HEAD k v o REFERENCE I SEE NOMBTE 1 I ONLY SHEET3I SEE NOTE1 I SEE NOTE 1 - I SHEET 3 SHEET316 I 16 SEE DETAIL II 1. 5 0 5 I u A' WHO n. 2N n1 i{ N 01 Oi y11A i J yy pp3 E ggo 0 o 111"', W/ 1X BUCK INSTALLATION 12 1 C 9 SEE NOTE1W/2X BUCK SHEET 3 INSTALLATION 3 t W/1XBUCK110DETAIL '1' INSTALLATION SEE NOTE 2 SHEET 3 DETAIL ' 3' B ATTACH ASTRAGAL THROW BOLT STRIKE PLATE TO FRAME AS SHOWN. 1 C 1 DETAIL '4' 2-1/2" MIN. FROM 2-1/r MIN. FROM 13 MASONRY EDGE MASONRY EDGE — TYP.) (TYP.) TX BUCK 5" W N INTERIOR EXTERIOR 1 HEAD JAMB ToSlm Ixi, mown 4 09•\/L` zzDT a0 t.2s INTERIOR 2 HEAD JAMB S To Wood ft. ftwing ou mn BUCK INTERIOR O i •' EXTERIOR m Or 25'MAX m SHIM SPACELL—LISIpm. 1.25* MIN. EMB. EMB. TYP. 4 VERTICAL SIDE JAMB S To x nung zoN cs U EXTERIOR INTERIOR EXTERIOR 1' MIN. FROM 1' MIN. FROM MASONRY EDGE MASONRY EDGE — TYP.) ITYP.) INTERIOR o.tsMw. CSWK 0.27 MAX. SHIM SPACE I.Is MIN. EMB. S VEMCAL SIDE JAMB S i Z m A EXTERIOR 3 HEAD JAMB S Tbx4g olovm N.T.S. 5 Or. JK m er. LFS 3 No WL. n 15225.5-68 c r-Lor6 o I MEw7MLil 2.1 /T MIN. FROM 2.1 /2' MIN. FROM f- MASONRY EDGE MASONRY EDGE rrP.) (TYP.) 1 VERTICAL CROSS SECITON b Inswing configwot. INTERIOR P 4mS 13 2-1/7'MIN.FROM 2-1/2MIN FROM MASONRY EDGE— MASONRY EDGE y TYP) (TYP.) 4 VERTICAL CROSS SEC110N b Inswng conngurotion EXTERIOR 1 2-1/7' MIN. FROM 2-1IT MIN. FROM MASONRY EDGE MASONRY EDGE TYP.) (TYP.) 2 VERTICAL CROSS SEC110N b Outswing conngml'ion o N n \ INTERIOR EXTERIOR PO suzea = ZO id lt X5 21 2.1/2" MIN•fROM 2.1/2" MIN. FROM MASONRY EDGE MASONRY EDGE . TYP.) (TYP.) i 0 3 VEIMCAL CROSS SECTION m ' EXTERIOR INTERIOR EXTERIOR INTERIOR 2-1 /T MIN. FROM— 2-1 /7• MIN. FROM f MASONRY EDGE MASONRY EDGE — ITYP.) (TYP ) 1 VERTICAL CROSS SECTION b Outswing connguration 2-1/2"MIN. FROM 2-1 IT MIN. FROM t MASONRY EDGE MASONRY EDGE— TYP ) ITYP.) VEIMCAL CROSS SECTION b Outswing connguiotion N.T.S. a er JK m er LFS ; n 15225.5-68 c L cr 6 a OFFICE Business ProfessionEd Regulation T rrl ram® rv'.tN dlUfieflI? Busines glib Professional BCIS Home ; Log In ; User Registration Produt t Approval Hot Tbp3Cs Submit Surcharge Slats 6 Fact$ Publications j FBC stall ! SCIS Site Hap Unks 1 Search USER, PUDIIC User Regulation J Plbauct Approval Menu > Product Application arch Se > doollcation U5[ > Application Detail PERMIT # , S 7 ( , er FL # FL2346-R5 Application Type Affirmation Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Warrior Roofing Manufacturing Address/ Phone/Email 3050 Warrior Road Tuscaloosa, AL 35404 205) 553-1734 Ext115 Steven@WarriorRoofing. net Authorized Signature Steven Crew Steven@WarriorRoofing. net Technical Representative Steven Crew Address/ Phone/Email 3050 Warrior Road Tuscaloosa, AL 35404 205) S53-1734 Ext1024 Steven@ W arriorFtoofing. net Quality Assurance Representative Steven Crew Address/ Phone/Email 3050 Warrior Road Tuscaloosa, AL 35404 205) 553-1734 Ext1024 Steven@WarriorRoonng. net Category Roofing Subcategory Underiayments Compliance Method Test Report Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 10/05/2019 Validated By Jesus Gonzalez, P.E. 1 Validation Checklist - Hardcopy Received Certificate of independence FL2346 R5 CQJ PRI CMT Cert of Ind o ndence.odf Referenced Standard and Year (of Standard) Standard Year ASTM D226 2006 ASTM D4869 2005 Equivalence of Product Standards Certified By I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes- No . N/A Product Approval Method Method 1 Option B Date Submitted 02/13/2015 Date Validated 02/13/2015 Date Pending FBC Approval Date Approved 02/19/2015 Summary of Products FL A Model, Number or Name Description 2346.1 ft 15 and #30 roofing felt ASTM D 226 Tested Limps of Use Installation Instructions Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A FL2346 R5 If Installationinstruction .ocif Verified By: PRI Construction Materials Technologies, LLC Test Reports FL2346 RS TR I SA Test Reoort.odf Other: Primary roof covering should be installed FL2346 R5 TR 30A Test Reoort.odf immediately after felt. Roofing felt is not intended to be an unprotected weathering surface. 2346.2 15w and 30w roofing felt ASTM D 4869 Tested Limits of Use Installation Instructions Approved for use In HVHZ: No FL2346 RS 11 Installation lnstructions.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Verified By: PRI Construction Materials Technologies, LLC Test Reports FL2346 RS TR 1Sw Test Reoort.ocif Other: Primary roof covering should be Installed FL2346 R5 TR 30w Test R oort.ndf immediately after felt. Roofing felt is not intended to be an unprotected weathering surface. eack Host Sys :: 1940 Herth Monroe Street. Tallahassee FL 32399 phone: 850-487.1824 The State of Florida is an AA/EEO arnployer. Copyright 2007.2013 state of Florida.:: Privacy Statement :; Aocesslbility Statement ;: Refund Statement Under Florida law. email addresses are public records. If you do not want your e-mail address released In response (o a public records request. do not send electronic mall to this entity. Instead, contact the office by phone or by traditlonal mail. If you have any questions, please contact 950.487.1395. •Purswm m Section 455.27S 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter aSS, F.S. must provide the Depanment with an email addressed they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. IF you 00 not wish to supply a personal address, phase provide the Department with an email adorns which can be made available to the public. To determine If you are a licensee under Chapter eSS, F.S., please click bM. Product Approval Accepts: art rmmmmmm CreditSA d 01 caeorrEo CONSTRUCTION MATERIALS TECHNOLOGIES CR, C r LABORATORY TEST RESULTS Report for: Warrior Roofing Manufacturing 3050 Warrior Road Tuscaloosa, AL 35405 Attention: Steven Crew Product ID(s): #30 Manufacturer: Warrior Roofing Manufacturing Tuscaloosa, AL) PRI-CMT Project No.: WRMI-008-02-02 Source: Warrior Roofing Manufacturing Date Received: Jul. 24, 2008 Date(s) Tested: Jul. 29, 2008 — Aug. 8, 2008 Purpose: Evaluate Warrior Roofing Manufacturing's (Tuscaloosa, AL) #30 for compliance with ASTM D 226: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. Test Methods: Testing was completed as described in ASTM D 226-06, -05, and -97a: Standard Specification for Asphalt -Saturated Organic Felt Used in Roofing and Waterproofing. Test methods assigned or referenced include ASTM D 70: Standard Test Method for Density of Semi -Solid Bituminous Materials Pycnometer Method); ASTM D 146: Standard Test Methods for Sampling and Testing Bitumen -Saturated Felts and Woven Fabrics for Roofing and Waterproofing: and ASTM D 6136: Standard Test Method for Kerosine Number of Unsaturated (Dry) Felt by Vacuum Method. Sampling: The sample received from Warrior Manufacturing on July 24, 2008 was a full factory labeled roll of felt. WRMI-008-02-02 PRI-CMT Accredilations: IAS TL-189: Miami -Dade 11-0429.05: Florida TST5878: Los Angeles TA24819: CRRC The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report PRI Corstriclron bloteriah Technologies LLC 6408 Saeger Onve Tampa, FL 33610 Tel: $13-621.5777 Fax 813.621.5840 o-n4l materi&tes6ny@orirml corn webRe W01.hwa rncml com Warrior Roofing Manufacturing ASTM D 226 for 30 Page 2 of 3 Results of Testing: PropertyI Requirement Result I Type 11 Physical Requttrtaments ' - Breaking Strength (Ibf/in-width) 20 specimens; 1" x 6" x thickness; Cond. 2h @ 73.4t3.6"F & 50±5%RH; Test 73.4±3.6"F• Rate=tin/min ASTM D 146 Longitudinal (with fiber grain) 66 z 30 40 Transverse (across fiber grain) 30 z 15 t 20 Pliability (Pass/Fail] 10 specimens; 1" x 8" x thickness; Cond. 10-15min in water @ 77±1.80F; Test 90" around radius in 2s ASTM D 146 radius radius Longitudinal (with fiber grain) Pass No Failures No Failures Transverse (across fiber grain) Pass No Failures No Failures Loss on Heating (weight %) 2 specimens, 12" x 6" x thickness; Test Cond. 221±59F for 5h±3min ASTM D 146 2 54 s 4 Dimensions and Masses Width of Roll (in) ASTM D 146 36 36 36 I Variation, % 0.3 0.7 0.7 Area, min (ft) ASTM D 146 216 432 216 Moisture at Point of Manufacture (%) ASTM D 146 NT 5 4.3 5 4.1 As Received' 3.0 5 4.3 5 4.1 Net Mass of Saturated Felt (lb/100ft2) ASTM D 146 27.3 Z 11.5 z 26 Mass of Saturant (Ib/100ft) ASTM D 146 15.9 z 6.2 z 15.0 Percent Saturation (%) ASTM D 226 150 120 a 150 Saturation Efficiency (%) ASTM D 226 NA t 70 Mass of Desaturated Felt (lb/100ft) ASTM D 146 10.6 z 5.2 10.0 Ash (%) ASTM D 146 4.0 510.0 510.0 Continued on Following Page The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any forth can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility not makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRl ConsMxk-n Materrals Talmo" -.es L L C 6108 8Wger Dore Tampa. FL 33610 Tel: 813-621.5777 Fa> 813621.SM t•wwl. material xting&itml con WebSrle' hop 96,*w.prirmtcom Warrior Roofing Manufacturing ASTM D 226 for 30 Page 3 of 3 NT- Not Tested; NA- Not Applicable Statement of Compliance: The product tested is compliant with ASTM D 226: Standard Specification for Asphalt -Saturated Organic Felt Used In Roofing and Waterproofing as Type II (No. 30). -_ Signed: Signed: Brad rz_ybows i Managing Director Date: 11 /c( / 1 Date: Report Issue History: Issue ft Date Pages I Revision Description (if applicable) Original 07/24/2008 3 NA Revisionl 11/09/2011 3 Revised to exclude reference to Florida Building Code 2007. Reissued. END OF REPORT The test results, opinions, or interpretations are based on the material supplied by the client. This report is for the exclusive use of stated client. No reproduction or facsimile in any form can be made without the client's permission. This report shall not be reproduced except in full without the written approval of this laboratory. PRI Construction Materials Technologies LLC assumes no responsibility nor makes a performance or warranty statement for this material or products and processes containing this material in connection with this report. PRI Corstnxion Materials iechno"ies LLC 6408 8xiger ()rive Tampa, FL 33610 Tel; 813.6215777 Far, 03.621.58A0 e•mW: maWri&testil1Q@P MLoom 'NebSite: h;tp lrxMx.pncmlcom WARRIOR® ROOFING MANUFACTURING P. 0. BOX 40185 • TUSCALOOSA, AL 35M • PHONE (206) 553.1734 • FAX (205) $53.1755 193 LEROY ANDERSON ROAD • MONROE. GA 3MS • PHONE (770) 207-0695 • FAX (770) 207-0775 323 DEVELOPMENT AVENUE • CHAMBERSBURG, PA 17201 • PHONE (117) 7094123 • FAX (717) 7094W Roofing Felt Installation Recommendations Be aware that roofing felt should not be walked upon prior to fastening into position. Proper safety equipment is recommended for all installations. Also, the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking, from edge to edge. Overhang is not required. Anchor the top corner of the felt after it has been properly positioned and roll the felt out across the roof. Pay careful attention to roll the felt out smoothly, avoiding wrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. The middle and bottom edge should also be fastened no less than every eight inches. Fasteners should be applied no less than every eight inches along the eaves. The next course of felt should also be aligned with the roof edge and should overlap the previous course two inches (sometimes referred to as head lap). In the event you get to the end of a roll prior to getting to the opposite edge of the roof, begin a new roll with a four inch overlap over the end of the prior roll (sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course, fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the roof. Otherwise, overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys, lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley, be certain to start at the bottom and overlap each subsequent length a minimum of two inches as you move up the valley to insuie•piopwater shedding. '=._,.• -:w =:tM_ l`-}' `i r Cy/{•' ••! 1-:. •• • y1. •• In the event some wrinkles are created while fastening down a course of felt, slice the wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering (ex. Shingles) is recommended immediately after felt installation. NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. 7R82015 Florida Building Code Online 1 r flcrda ' K i'p wrientt: SCIS Home Log In User Registration i Hot Topics Submit Surcharge ; Stats 8 Facts publications FBC Staff SCIS Site Map . Links Search Busines ; Professirral product Approval UsPERMIT# 7, 7C USER: public War Regulation PICCIM Approval Menu > Product or ADDlltation Search > Application List > Application Detail FL # FL1956-R11 Application Type Revision Code Version 2014 Application Status Approved OFFICE Comments Archived Product Manufacturer Address/ Phone/Email Authorized Signature Technical Representative Address/ Phone/Email Quality Assurance Representative Address/ Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Product Approval Method Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. TAMKO Building Products, Inc. PO Box 1404 Joplin, MO 64802 417) 624-6644 Ext 2305 kerri_ eden@tamko.com Kerri Eden kerri-. eden@tamko.com Kerri Eden PO Box 1404 Joplin, MO 64802 417) 624-6644 Ext2305 kerri_ eden@tamko.com Roofing Asphalt Shingles Certification Mark or Listing UL LLC Robert 1. M. Nieminen, PE Validation Checklist - Hardcopy Received Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Method 1 Option A helps:// floridabUlding.org/pr/pr app dU.aspx?Wam=wGEVXC) v Dqs%2fmGFoyT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2bKOdb01OIBWlo3d%3d 1/4 7/2 O15 Florida Building Code Online Date Submitted 03/20/2015 Date Validated 04/02/2015 Date Pending FBC Approval Date Approved 04/06/2025 FL 0 Model, Number or Name Description 1956.1 Elite Glass -Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FI_1956 RI C CAC Tamko S ry Conf FL 1956 env odf Approved for use outside FL1956 R11 C CAC ui certification 10_++-12 df HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other. Asphalt shingles shall be FL1956 R11 ii Glass Seal Elite Glass Seal aoD inst Ddf used only on roof slopes of 2:12 Verified By: Robert Nieminen 59166 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.2 1 Glass -Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 RI C CAC Tamko Sery Conf FL 1956 2012.odf Approved for use outside FL1956 g++ r_ ror_ :::=_t:_rir_.:__ f HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 li Glass Seat Elite Glass Seal aoo inst Ddf used only on roof slopes of 2:12 Verified By: Robert Nieminen PE 59166 or greater. Nails must be used Created by Independent Third Party: No as the method of attachment. Evaluation Reports Created by Independent Third Party: 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL1956 R11 C ror Tamko S_ • Conf FL 1956 2012 vdfIApprovedforuseoutsideFL19561111Crorutrartifirztlnin-++_+i ..ar Impact Resistant: N/A 10/10/2015 r Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 1131 11 Heritage D F 3 P ago inst Ddf used only on roof slopes of 2:12 FL1956 R11 1I Heritage F ago inst odf or greater. Nails must be used FL1956 R31 If Heritage T ago inst odf as the method of attachment. Verified By: Roberti. M. Nieminen FL 59166 Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 R31 C C.or Tamko Sery Conf Fl. 1956 2012Ddf Approved for use outside FL1956 R11 C CAC UL certification 10-11-12 Ddf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 i1 heritage 30 ago inst aoril 10 Ddf used only on roof slopes of 2:12 r rSt : aurii 10 oo'f or greater. Nails must be used Verified By: Robert Nieminen PE 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: 1956. 5 1 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL1956 III C CAC Tamko Sery Canf FL 2956 2012 odf Approved for use outside FL1956 RI I C ror t n certification 10 11 1? ndf HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 10/10/2015 Design Pressure: N/A Installation Instructions Other: Asphalt shingles shall be FL1956 R11 it heritage sn ann inct aoril 10 odf used only on roof slopes of 2:12 FL1956 R11 iI heritage 50 ago Inst f aoril 10.odf or greater. Nails must be used Verified By: Robert Nieminen PE 59166 as the method of attachment. Created by Independent Third Party: No Evaluation Reports Created by Independent Third Party: blipsJilloridabuilding. org/pr/pr app du.aspx7param=wGEVXCroADgs%2fmGFovT6raQ%2b%2bCX5ulUhEA3ULv8xAB4z%2hKAdhcNnlFavc(.W6.,-*i gyre Application Instructions for TA HERITAGEO 30 BU16DING PRODUCTS LAMINATED ASPHA6T SHING6ES Dallas, TX 9 Tuscaloosa, AL • Phillipsburg, KS • Joplin, MO THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY, THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER (BELOW 40°F), CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT: It is not necessary to remove the plastic strip from the back of the shingles. 1. ROOF DECK These shingles are for application to roof decks capable of receiving and retaining fasteners, and to Inclines of not less than 2 In, per foot. For roofs having pitches 2 in. per foot to less than 4 in. per foot, refer to special instructions titled "Low Slope Application". Shingles must be applied properly. TAMKO assumes no responsibility for leaks or defects resulting from improper application, or failure to properly prepare the surface to be roofed over. NEW ROOF DECK CONSTRUCTION.• Roof deck must be smooth, dry and free from warped surfaces. It is recommended that metal drip edges be installed at eaves and rakes. PLYWOOD: All plywood shall be exterior grade as defined by the Engineered Wood Association. Plywood shall be a minimum of 3/8 in. thickness and applied in accordance with the recommendations of the Engineered Wood Association. SHEATHING BOARDS: Boards shall be well -seasoned tongue - and -groove boards and not over 6 in. nominal width. Boards shall be a 1 in. nominal minimum thickness_ Rnards chap ho nrnnorh, 2. VENTHATION Inadequate ventilation of attic spaces can cause accumulation of moisture in winter months and a build up of heat in the summer. These conditions can lead to: 1. Vapor Condensation 2. Buckling of shingles due to deck movement. 3. Rotting of wood members. 4. Premature failure of roof. To insure adequate ventilation and circulation of air, place louvers of sufficient size high in the gable ends and/or install continuous ridge and soffit vents. FHA minimum property standards require one square foot of net free ventilation area to each 150 square feet of space to be vented, or one square foot per 300 square feet if a vapor barrier is installed on the warm side of the ceiling or if at least one halt of the ventilation is provided near the ridge. If the ventilation openings are screened, the total area should be doubled. IT IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION. S. FASTENERS WIND CAUTION: Extreme wind velocities can damage these shingles after application when proper sealing of the shingles does not occur. This can especially be a problem if the shingles are applied In cooler months or in areas on the roof that do not receive direct sunlight. These conditions may Impede the sealing of the adhesive strips on the shingles. The inability to seal down may be compounded by prolonged cold weather conditions and/ or blowing dust. In these situations, hand sealing of the shingles is recommended. To insure immediate sealing, apply 4 quarter -sized dabs of TAM -PRO'' Premium SBS Adhesive or TAMKO Tam -Seal Adhesive on the back of the shingle 1 In. (25mm) and 13 in. (330mm) in from each side and 1 in. (25mm) up from the bottom of the shingle. Press shingle firmly into the adhesive. For maximum wind resistance along rakes, cement shingles to the underlayment and each other in a 4 in. (102mm) width of TAM -PRO SBS Adhesive or TAMKO Tam -Seal Adhesive. Caution: Apply ONLY a thin uniform layer of adhesive less than 1/8 in. (3mm) thick. Excessive amounts can cause blistering of the shingles and may soften the asDhalt in staining. Shingles must also be fastened according to the fastening instructions described below. Correct placement of the fasteners is critical to the performance of the shingle. If the fasteners are not placed as shown in the diagram and described below, this will result in the termination of TAMKO's liabilities under the limited warranty. TAMKO will not be responsible for damage to shingles caused by winds in excess of the applicable mph as stated in the limited warranty. See limited warranty for details. FASTENING PATTERNS: Fasteners must be placed 6-1/8 in. from the bottom edge of the shingle, penetrating through the common bond, and located horizontally as follows: 1) Standard Fastening Pattern. (For use on decks with slopes 2 in. per foot to 21 in. per foot.) One fastener 1 in. back from each end and one 13-1/2 in. back from each end of the shingle for a total of 4 fasteners. (See standard fastening pattern illustrated below). STANDARD FASTENING PATTERN FASTENERS NAIL ZONE COMMON BOND EXPOSURE 5.518" I 1=-q I -- 12-1/2"-+-12-3/E" —- 12-1/2" H" Continued) Central District 220 West 4th St., Joplin, MO 64801 800-641-4691 » Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District tamko.com 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 1 TAMKO 6016DIN0 PRODUCTS CONTINUED from page 1) HERITAGEO 30 LAMINATED ASPHALT SHINGI6ES Dallas, TX • Tuscaloosa, AL * Phillipsburg, KS • Joplin, MO 2) Mansard Fastening Pattern. (For use on decks with slopes greater than 21 in, per foot.) One fastener 1 in. back from each end and one fastener 8-1/2 in. back from each end and one fastener 16 In. back from each end for a total of 6 fasteners per shingle. (See Mansard and High Wind Fastening Pattern Illustrated below.) MANSARD AND HIGH WIND FASTENING PATTERN FASTENERS NAIL ZONE COMMON BOND n [7 R EXPOSURE55W 3) High Wind Fastening Pattern. (For High Wind Application requirements) One fastener 1 in. back from each end. One fastener 8-1/2 in. back from each end and one fastener 16 in. back from each end for a total of six (6) fasteners per shingle. In addition to this shingle fastening pattern requirement for High Wind Application, TAMKO also requires the use of the following TAMKO products: TAMKO felts or underlayments; TAMKO Moisture Guard Plus underlayment at all eaves, rakes, and valleys: TAMKO or TAM -PRO cements and coatings products where required; TAMKO ventilation where required, TAMKO starter shingles if available in area, and TAMKO Hip and Ridge shingles installed on all hips and ridges. Along rakes, cement shingles to the underlayment and each other in a 4 in. (102 mm) width of TAM - PRO SBS Adhesive or TAMKO Tam -Seal Adhesive. Also, see local building codes for proper nailing application. High Wind Application Is offered on new construction or complete tear -off applications only. It is not offered for recover applications. If High Wind Application MPH, as stated on Table I in the Limited Warranty, reverts to the Standard Application Wind Warranty MPH limit. (See Mansard and High Wind Fastening Pattern illustrated above.) NAILS: TAMKO recommends the use of nails as the preferred method of application. Standard type roofing nails should be used. Nail shanks should be made of minimum 12 gauge wire, and a minimum head diameter of 318 in. Nails should be long enough to penetrate 3/4 in. into the roof deck. Where the deck is less than 314 in. thick, the nails should be long enough to penetrate completely through plywood decking and extend at least 1/8 in, through the roof deck. Drive nail head flush with the shingle surface. Properly often tmpropCV orwen Yd roinOWnotcr underdrlrsn oterdrlvm Cooked Aspholl Shbvtos j.1/a•nerrrWl Weight, good penMUon Inodepuate too desp. cuts Irodepusto and Irish MN shbl& surface P"MUen loro Wngle ant:horoge STAPLES: If staples are used in the attaching process, follow the above instructions for placement. All staples must be driven with pneumatic staplers. The staple must meet the following minimum dimensional requirements. Staples must be made from a minimum 16 gauge galvanized wire. Crown width must be at least 15/16 in. staple crown width is measured outside the legs). Leg length should be a minimum of 1-1/4 in. for new construction and 1-1/2 in. for reroofing thus allowing a minimum deck penetration of 3/4 in. The crown of the staple must be parallel to the length of the shingle. The staple crown should be driven flush with the shingle surface. Staples that are crooked, underdriven or overdriven are considered improperly applied. Properly Driven Improperly Driven Iea H unde*A" owak;ven crooked S al Deddng CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE NAIL ZONEICOMMON BOND AS SHOWN IN THE DIAGRAM ABOVE. 4. UNDERLAYMENT UNDERLAYMENT: An underlayment consisting of asphalt saturated felt must be applied over the entire deck before the installation of TAMKO shingles. Failure to add underlayment can cause premature failure of the shingles which is not covered by TAMKO's limited warranty. Apply the felt when the deck is dry. On roof decks 4 in. per foot and greater apply the felt parallel to the eaves lapping each course of the felt over the lower course at least 2 in. Where ends join, lap the felt 4 in. If left exposed, the underlayment felt may be adversely affected by moisture and weathering. Laying of the underlayment and the shingle application must be done together. Products which are acceptable for use as underlayment are: A non-Derforated asphalt saturated organic felt which meets ASTM: D226, Type I or ASTM D4869, Type I Any TAMKO non -perforated asphalt saturated organic felt TAMKO TW Metal and Tile Underlayment, TW Underlayment and Moisture Guard Plusm (additional ventilation may be required. Contact TAMKO's Technical Services Department for more information.) In areas where ice builds up along the eaves or a back-up of water from frozen or clogged gutters is a potential problem, TAMKO's Moisture Guard PlusP waterproofing underlayment (or any specialty eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent water damage. Contact TAMKO's Technical Services Department for more information. TAMKO does not recommend the use of any substitute products as shingle underlayment. S. APPLICATION INSTRUCTIONS STARTER COURSE: A starter course may consist of TAMKO Shingle Starter, self-sealing 3-tab shingles or a 9 inch wide strip of mineral surface roll roofing. If self-sealing 3-tab shingles are used, remove the exposed tab portion and install with the factory applied adhesive adjacent to the eaves. Attach the starter course with approved fasteners along a line parallel to and 3 in. to 4 in. above the eaves edge. The starter course should overhang both the eaves and rake edges 1/4 in. to 3/8 in. Central District 220 West 41h St., Joplin, MO 64801 800-6414691 ++fog Visit Our Web Site at Northeast District 4500 Tamko On. Frederick, MD 21701 800-366-2055 Southeast District tamko.eom 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 2 NEW ETA:M:MK0fl BUILDING PRODUCTS CONTINUED from page 2) I ERITAGIC® 30 LAMINATED ASPHA6T SHINGLES Dallas, TX o Tuscaloosa, AL * Phillipsburg, KS • Joplin, MO SHINGLE APPLICATION: Start the first course with a full size shingle and overhang the rake edge 1/4 in. Cut 10-3/8 in. from a full shingle to form a shingle 29 in. long. Use this to start the second course (see diagram below). Cut a 23 in. long shingle to start the third course. Use the remaining 16-3/8 in. piece of shingle to start the fourth course and use the remaining 10-3/8 in. piece to begin the fifth course. Continue up the rake in as many rows as necessary using the same formula as outlined above. The butt of the shingle should be aligned with the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. exposure (see shingle application drawing illustrated on this panel). When you make your final cut at the roof's edge, flip any pieces that are 8 in. or longer back onto the roof. These pieces can be worked In anywhere without creating zippers or color variations. NOTE: Do not align joints of shingle courses when working in cut pieces. Joints should be no closer than 4 in. from one another. l33/9• repeat 3y'r i 23.• roko 3rdwutis httr Course' Y3e_..L:•23. 29! tit Como F. 10.91a" r l0v0 mow. J.C. rev t ateo.n. stilly. l.—ko 1P aeo6103V P.COaselW W-00New002Wam a to 3T by k AS 2aayeo' ioi, tnio. A. yN Can w. WsNnil.a wan two wN maa M1.auaa. 3CGf CIA ' ,Aura• rqn Ma/ -Y Ole toys. Y we felt sR d1oiu rnatof ATht"ogo,doCMbeimoI,WAtrq• C081anbm.rm, a" N. * aeasM..OtiannnWow17W1 XON:;ry eMI 01COIVofshiCWMo. eel NS'hblb.t aMCIDc.ura..wrenrm to cut poaa hlnN aM.W W ne etew Uun.• born en..eom.r. 6. LOW SLOPE APPLICATION On pitches 2 in. per foot to 4 in. per foot cover the deck with two layers of asphalt saturated felt. Begin by applying the felt in a 19 in. wide strip along the eaves and overhanging the drip edge by 1 /4 to 314 in. Place a full 36 in. wide sheet over the 19 in. wide starter piece, completely overlapping it. All succeeding courses will be positioned to overlap the preceding course by 19 in. If winter temperatures average 25OF or less, thoroughly cement the felts to each other with TAM -PRO or TAMKO Plastic Roof Cement from eaves and rakes to a point of a least 24 in. Inside the interior wall tine of the building. As an alternative, TAMKO's Moisture Guard Plus® self - adhering waterproofing underlayment may be used In lieu of the cemented felts. 7. MANSARD ROOF OR STEEP SLOPE ROOF If the slope exceeds 21 in, per foot (60), each shingle must be sealed with TAM -PRO SBS Adhesive or TAMKO Tam -Seat Adhesive immediately upon installation. Spots of cement must be equivalent in size to a $.25 piece and applied to shingles with a 5-5/8 in. exposure, use 6 fasteners per shingle. See Section 3 for the Mansard Fastening Pattern. 8. RE -ROOFING Before re -rooting, be certain to inspect the roof decks. All plywood shall meet the requirements listed in Section 1. Nail down or remove curled or broken shingles from the existing roof. Replace all missing shingles with new ones to provide a smooth base. Shingles that are buckled usually indicate warped decking or protruding nails. Hammer down all protruding nails or remove them and refasten in a new location. Remove all drip edge metal and replace with new. If re -roofing over an existing roof where new flashing is required to protect against Ice dams (freezelthaw cycle of water and/or the backup of water in frozen or clogged gutters), remove the old roofing to a point at least 24 in. beyond the interior wall line and apply TAMKO's Moisture Guard Plue waterproofing underlayment. Contact TAMKO's Technical Services Department for more Information. Measurements will vary when nesting over an existing 5 in. exposure single roof: Call TAMKO Technical Services for further information. The nesting procedure described below is the preferred method for reroofing over existing metric size shingles with a 5-5/8 in. exposure. See description below: Starter Course: Remove the tabs and an additional portion from the head of a full size shingle so that its height is equal to the exposure of the existing shingles. Position the resulting strip over the existing roof edge (with the factory -applied adhesive strip along the eaves). Cut approximately 6 in. from the rake end and apply the remaining portion at the eaves. Continue the starter strip by applying full length shingle strips cut to height as above, evenly along the existing roof at the eaves. The existing roof should overhang the eaves far enough to carry water off into the gutter. If this is not the case, cut and apply the starter strip so that it will provide sufficient overhang for proper drainage. First Course: Remove an amount from the butt edge of a full-size shingle so that the remaining portion of the shingle fits between the butts of the existing third course. This course must also be applied evenly along the eaves edge of the new starter strip. Central District 220 West 4th St., Joplin, MO 64801 800-6414691 11M9 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District tamko.coim 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp., Dallas, TX 75216 800443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 800-530-8868 3 TAMKO BUWDING PRODOC9'S CONTINUED from page 3) LAMINATED ASPHALT SHINGLES Dallas, TX a Tuscaloosa, AL a Phillipsburg, KS • Joplin, MO Second and SucceedingCourses: Remove 10-3/8 in. from the rake end of the first shingle in the second course, and continue with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old shingle in the course above. This method should create an exposure of 5-5/8 in. after the first course. When beginning the succeeding courses continue to follow the Heritage application instructions. See section 5). Drip No 9. VALLEY APPLICATION Over the shingle underlayment, center a minimum 36 in. wide sheet of TAMKO Nail -Fasts, Moisture Guard Plus° or a minimum 50 lb. roll roofing in the valley. Nail the felt only where necessary to hold it in place and then only nail the outside edges. PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING SHINGLES TO FORM VALLEY. After valley flashing is in place: Apply the first course of shingles along the eaves of one of the Intersecting roof planes and across the valley. Note: For proper flow of water over the trimmed shingle, always start applying the shingles on the roof plane that has the lower slope or less height. Extend the end shingle at least 12 in. onto the adjoining roof. Apply succeeding courses in the same manner, extending them across the valley and onto the adjoining roof. Press the shingles tightly into the valley. Use normal shingle fastening methods. Note: No fastener should be within 6 in, of the valley centerline, and two fasteners should be placed at the end of each shingle crossing the valley. To the adjoining roof plane, apply one row of shingles vertically facing the valley and 2 in. back from the valley centerline. Note: For a neater installation, snap a chalkline over the shingles for guidance. To complete the valley, apply shingles on the adjoining roof plane by positioning the tip of the first shingle of each row at the 2 in. point from the centerline where the edge of the vertical shingle has been applied, covering the vertical shingle. FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT. trroaleyMml <-,S A..,VWgant&lr* place ap Of ShAtY. an the eeppoo of tM.en,cu eti+Ip10 es26KhbocA C::= canstwgb. onsano mbing 10. HIP AND RIDGE FASTENING DETAIL Extend ero 9"lo 12'- ur br/ano vaaey centone Noasteners-.- A" 6' ar cMtenew Apply the shingles with a 5 in. exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing winds. Secure each shingle with one fastener on each side, 5- 1/2 in. back from the exposed end and 1 in. up from the edge. TAMKO recommends the use of TAMKO Hip 8 Ridge shingle products. Where matching colors are available, it is acceptable to use TAMKO's Elite Glass -Seal shingles cut down to 12 in. pieces. Fasteners should be 1/4 in. longer than the one used for shingles IMPORTANT PRIOR TO INSTALLATION, CARE NEEDS TO BE TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING SHINGLE IN COLD WEATHER. Direction of prevailing wind plart 5' exposure here- Fastener 5. xposure THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS, INC. ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER' S INSTRUCTIONS. TAMKOO, Moisture Guard Plus9. Nail Fast®. TAM -PRO+ and Heritaga are registered trademarks of TAMKO Building Products, im, Information Included in these application Instuctions Vras current at lime of printing. To obtain a copy of the most current version of Mesa application Instructions, visit us online at tamkc.com or call us at ag0.641-4691. Central District 220 West 4th St„ Joplin, MO 64801 800-6414691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District tamko. Com 2300 35th St., Tuscaloosa, AL 35401 800-228-2656 Southwest District 7910 S. Central Exp., Dallas, TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver, CO 80216 Rim 800- 530-8868 4 October 10, 2012 Tamko Building Products 220 W 4th Street PO Box 1404 Joplin, MO 64801 Contact Name: Kerri Eden Email Address: Kerri EdenOtamko com Subject: UL Third Party Inspection Service for Florida Quality Assurance Expiration Date: October 10, 2015 Reference: File R2919 Dear Ms. Eden: This letter is to confirm that Tamko Building Products has an agreement with UL LLC to conduct audits at your plant to verify Florida Quality Control requirements at the following locations: Tamko Building Products 601 N. High St Joplin MO 64801 Tamko Building Products 7910 S Central Expy Dallas TX 75216 Tamko Building Products 1598 Hwy 183 Phillipsburg KS 67661 Tamko Building Products 4500 Tamko Dr Frederick MD 21704 Tamko Building Products 2300 35`h St Tuscaloosa AL 36401 Quality Control System and Products will be inspected according to Florida Product Approval ReportFL1956toensurethemanufacturer's quality documentation is well defined, fully documented andeffectivelyimplemented. A minimum of two (2) inspections per year will be conducted. This service has been establishedunderfileR2919. UL LLC 333 Pfingsten Road. Northbrook, IL 60062.2096 USA T: 847.272.8800 / F: 847.272.8129 / W: UL com If you have any questions, please call me at 314-578-3406. Kind regards, A&ee-&, J. Kay Chancellor Project Coordinator Product Safety UL LLC 333 Pfingsten Road Northbrook, IL 60062-2096 USA M:314-578-3406 F: 847-664-6157 W: ul.com October 1 I, 2012 Tamko Building Products Inc Ms. Ken: i Eden 220 W 4th St PO Box 1404 Joplin, MO 64801 RE: TAMKO Shingles Dear Ms. Eden: This is to confirm that the attached shingle matrix pertains to Tamko produced shingles. All the products have been tested and meet the criteria for the standards mentioned. They are covered byUL's Follow -Up Service Program under Tamko's File R2919. The Listing Mark of Underwriters Laboratories Inc. on the product is the only method provided by UL toidentifyproductsmanufacturedunderitsListingandFollow -Up Service. Combination Listing/Classification Mark — A Listing Mark combined with a Classification Mark is provided on products that have additionally been investigated in accordance with various supplemental standards. Please refer to_theJabels_on_the-product. Should you have any questions, please feel free to contact the writer. Very truly yours, William G Marshall (Ext. 42735) Sr. Engineering Associate Fire Protection Division 3019A Reviewed By: Alpesh Patel (Ext. 42522) Staff Engineer Fire Protection Division 3019A Phillipsburg, RS Product Name ASTt! ASTM ASMI M. hSTV CSA D2462 D2162 DE281 2290 D7158 123.5 Class Class Class Class F H H H Glass -Seal (AR) Elite Glass -Seal QA) Heritage X x X X X X Heritage 20 (AR) X X x x x X Heritage )M (AR) Heritage 50 (AR) x x X x X x Heritage Premium x X X X x X Heritage Vintage (AR) X X X X X x Heritage Vintage Y. A 12 is 12 Hip and Ridge Dallas, TX Product Name ASTN AM ASTM III, ASTw CSA D3462 D3162 DE282 2390 D7158 122.5 Class Class Class Class F H H H Glass -Seal (ARJ Elite Glass -Seal (AR) Heritage X X x x X x Heritage 20 (AR) x x X X X X Heritage XL (AR) x X X X X Heritage Wwdgate x x X X x X Heritage 50 (AR) X X x X x X Heritage Premium X x x X X X Heritage Vintage (AR) Heritage IR x i( Y. x x X Shingle Yatrix Frederick, XD Product Name bSTN. AST' nSTK UL ASTu CSA D3462 D3161 D6281 2390 D7158 122.5 Class Class Class Class F H H H Glass -Seal (AR) X X X X X Elite G?ass-Seal (AR) x x X x X Heritage x x x X X x Heritage 30 (AR) x X x x x x Heritage U (AR) X x Heritage Woodgate f Heritage 50 (AR) X x x X x x Heritage Premium X x x x x x Heritage Vintage (ZR) 12-1/4 1 12 Hip and Ridge X X UL Product Race 2218 Glass -Seal (AR) Elite G:ass-Seal (M) Heritage Heritage 20 MR) Heritage XL (AR) Heritage 50 (AR) Heritage Premium Heritage Vintage (3R) X 12 X :2 Hip and Ridge Tuscaloosa, AL ASTM AMME ASTM IIL ASTiS CSA D2462 02161 D6281 2290 07158 123.5 Class Class Class Class F H H H x x x x x X x x x x X x X x X x x x x x X X x x x x x x x x x x x x xx Product Name Glass -Seal (AR) Elite Glass -Seal (AR) Heritage Heritage 30 (AR) Heritage XL (AR) Heritage 50 (AR) Heritage Premium Heritage Vintage (AR) 12 X 12 Hip and Ridge 12-1/4 x 12 Hip & Ridge Joplin, 143 ASTM 03462 ASTM D3161 Clas s F X - X X X X X X 06381 as H X X I ---- X X UL 2390 Class H X X X X AM. 07158 Class H X X X X CSA 123.5 X X S C UCI< EnginE=E=rinq Speclalty Structural Engineering CBUCK, Inc. Certificate of Authorization u8064 Evaluation Report PERMIT 1ce "MMI-2" Off Ridge Vento1q: Ridge Vent Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 877) 358-7663 for Florida Product Approval FL 16568.1 R1 Florida Building Code 5th Edition (2014) Per Rule 61G20-3 M-ethod: 2 - B Category: Roofing Sub - Category: Roofing Accessories that are an Integral Part of the Roof System Product: "MMI-2" Off Ridge Vent Material: Steel Support: Wood Deck Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Youry Demosthenes Report No. 14-104-MM12-StORV-ER_14 Date: 2 / 26 / 15 Contents: Evaluation Report Pages 1— 7 sm A. Irsys+c f.e.euN 1181u`, P . Or- No 31242 w= STATE OF j111111 1. 1 ' N h Fred EY• l,mc:l euc ne.. V.E MUCK, Inc. 2015.03.0210:57:51-05'00' 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net FL li: FL 16568.1 R1 Date: 2 / 26 / 15 CBUCK EnQ1neering Report No.:25-104-MM2-St0RV-ER_14 Page of 7 Specialtt j Structural Engineering MUCK, Inc. Certificote of Authorization a8064 Manufacturer: Product Name: Product Category: Millennium Metals, Inc. MMI-2" Off Ridge Vent Roofing Product Sub -Category Roofing Accessories that are an Integral part of the Roofing System Compliance Method: State Product Approval Rule 61G20-3.005 (2) (b) Product/System "MMI-2" Off Ridge Vent Description: Steel off ridge vent for shingle roofs mechanically attached to Plywood Deck. Product Assembly as Refer to Page 4 of this report for product assembly structural components: Evaluated: 1. Off Ridge Vent 2. Fasteners 3. Roof Cement Support: Type: Wood Deck Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: 15/32 (min.) or greater plywood, or Wood plank (min. specific gravity of 0.42) Slope: 2 : 12 or Greater Performance: Wind Uplift Resistance Design Uplift Pressure: - 75 PSF Allowable design pressure for allowable stress design (ASD) with a margin of safety of2to1. CHUCK EngineerInQ FL #: FL 16568.1 RI Date: 2 / 26 / 15 Report No.: 15-104-MM2-StORV-ER_14 Page 3 of 7 Speclalttj Structural Engineering OUCK, Inc. Certificate of Authorization #8064 Performance Standards: The following test protocols were performed to demonstrate compliance with the intent of the code as this product is not addressed specifically in the code. ASTM E330-02 — Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014), Section 1709.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements of Scope: the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. Refer to applicable building code section for ventilation requirements. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). CBUCK Engineering FL #: FL 16568.1 RI Date: 2 / 26 / 15 Report No.: 15-104-MM2-St0RV-ER 14 Page 4 of 7 Specialty Structural Engineerinq CBUCK, Inc. Certificate of Authorization #8064 Components/Materials Ridge Vent: "MMI-2" Off Ridge Vent by Manufacturer): Material Type 1: Steel Thickness: 26 gauge (min.) Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: ASTM A792 coated, or ASTM A653 G90 galvanized steel Nominal Dimensions: Width: 24„ Height: 4-1/2- Lengths: 2' , 4', 6', 8' and 10' Fastener(s): Base Fastener: Purpose: Attaches Ridge Vent Base Flange to Deck Type: Annular Ring Shank Roofing Nails Size : 11 gauge x 1-1/2" Corrosion Resistance: Per FBC Section 1506.5 Standard: Per ASTM F 1667 Alternate Fastener: Purpose: Attaches Ridge Vent Base Flange to Deck Type: Hex -Head Wood Screw Size : #10 x 1-1/2" (min.) Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 - Standard: Per ANSI/ASME B18.6.4 Roof Cement: Type: Asbestos -free asphalt based roof cement w/ SBS rubber Application Size: 1/4" thick minimum Standard: Per ASTM D 3019 Type III and ASTM D 3409 FL #: FL 16568.1 Rl Date: 2 / 26 / 15 C 8211UCK Engineering Page Report No.: 15-104 7- MM2-StORV-ER 14 ISpecialty Structural EnginPprinq CBUCK, Inc. Certificate of Authorization a8064 Installation: Installation Method: Refer to drawings on Pages 6-7 of this report.) Prepare deck opening by trimming any shingles & nails that may interfere with ridge vent installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should be a 1/4" thick and extend 2" onto roof underlayment. (Install cement in compliance with manufacturer's installation guidelines.) Position vent flange beneath loosened shingles and align with deck opening. Attach vent top, bottom and side flanges to deck with nails or screws spaced 4" o.c. and 1-1/2" from each end. Minimum fastener penetration thru bottom of support, 3/16". Install the "MMI-2 Off Ridge Vent" assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide -for -attachment. Referenced Data: 1. ASTM E330-02 Uniform Static Air Pressure Difference Test Architectural Testing, Inc.(FBC Organization #TST ID: 1527) Report #: D0249.02-450-18, Report Date: 8 / 29 / 13 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID:1824) Millennium Metals Licensee # 423 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE 1916) FL #: FL 16568.1 R1 Date: 2 / 26 / 15 C®UCK Eng1neerInQ RReBpeort No.: 11S-104-MM2-StORWER 14 Specialty Structural Engineering CBUCK, Inc. Certificote ofAuthorizotion u8064 Installation Method Millennium Metals, Inc. MMI-2" Steel Off Ridge Vent Attached to Wood Deck 4 Win I Val 5.1/ 2' Profile Drawines 18- V 4" 1.2" Side View (Not To Scale) Typical Fastener(s) 11 Gauge Ring Shank Roofing Nail OR 10 min. Wood Screws MMI-2" Steel Off Ftidge Vent Typical Fastener(s) 11 Gauge Ring Shank Roofing Nail OR 10 min. Wood Screws Plywood Deck Lower Slope Front) Typical Side View (Not To Scale) 3 Higher Slope Back) 1, FL #: FL 16568.1 R1 Date: 2 / 26 / 15 CB CK Engineering RRege rt No.: i of MM2-StORV-ER 14 Specialty Structural Engineprinq MUCK, Inc. Certificate of Authorization a8064 Installation Method Millennium Metals, Inc. MMI-2" Steel Off Ridge Vent Attached to Wood Deck 1 1/2" o.a. 1 W" 4" o.c. 4" o.c. Typical, Maximum T Typical Fastener(s) 111 Gauge Ring Shank Roaring Nail Base FlangeOR 10 min. Wood Screws Top Plan View (Not To Scale) Typical Fastening Pattern) Nominal Lengths 4 FL 6 FL 8 Ft. ,ae 10 Ft. ya a Typical Fasteners) 11 Gauge Ring Shank Roofing Nail OR Tom, - # 10 min. Wood Screws Typical Ridge Vent Assembly Isometric View (Not To Scale) 7n812015 Porida Depavientd aels Nome ! Login I User Registration I Hot Topics E Busines Professi gal Product Approval USER: public user Regulation Florida Building Code Online D9PR -. IlaQl7ip9%{.Dtl PR plYIf lO q'. rAfhAcYpBist Cubmit Surcharge StaltS Facts Publications FBC Staff SCIS Site Map Links Search PERMIT Product Approval Menu > Product or Application Search > Application List > Application'Detail FL # FL4904-117 Application Type Affirmation Code Version 2014 Application Status Approved Comments OFFICE Archived Product Manufacturer Masonite international Address/Phone/Email 1955 Powls Road West Chicago, IL 60185 615) 441-4258 sschrelber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Documentation from approved Evaluation or Validation Entity Product Approval Method Certification Mark or Listing National Accreditation & Management Institute National Accreditation & Management Institute, Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 1 affirm that there are no changes In the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Yes No N/A Method 1 Option A https://Boridabuilding.orglprlprppp o.aspx?param=wGEVXQMDgtelutwHNbbISciO%2baWgLuY,XbtTsEXplAQolo3d 114 7/28/2015 Florida Building Code Online Date Submitted Date Validated Date Pending FBC Approval Date Approved Products 04/29/2015 04/29/2015 05/04/2015 FL # Model, Number or Name Description 4904.1 Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S and O/S Single Door Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +76.0/-76.0 Other: Evaluated for use In locations adhering to the Florida Building Code Including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 3'-0" x 6'-B" max nominal size. When large missile impact resistance is required, hurricane protective system is NOT required. See DWG-MA-FLO128-05 for details. 4904.2 I Wood -edge Steel Side -Hinged Door Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70.0/-70.0 Other: Evaluated for use In locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 3'-0" x 8'-0" max nominal size. When large missile Impact resistance Is required, hurricane protective system is NOT required. See DWG-MA-FLO129-05 for details. Certification Agency Certificate FL4904 R7 C CAC NI006110.0l.odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL4904 R7 II FL0128.Ddf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4904 R7 AE 504A.odf Created by Independent Third Party: Yes 8'-0" Opaque I/S and O/S Single Door Certification Agency Certificate FL4904 R7 C CAC NI006110.0 _odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL4904 R7 iI FL0129.odf Verified By: National Accreditation & Management institute Created by Independent Third Party: Evaluation Reports FL4904 R7 AE 503A.odf Created by Independent Third Party: Yes Wood -edge Steel Side -Hinged Door 6'-8" Opaque I/S and O/S Door w/ or w/o Sidelites Units Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-55.0 Other: Evaluated for use in locations adhering to the Florida Building Code Including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 6'-8" max nominal size. When large missile impact resistance is required, hurricane protective system Is NOT required on opaque panels, but is required on glazed panels. See DWG- MA-FL0128-05. Certification Agency Certificate FL4904 R7 C CAC NI006110.0l.odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL4904 R7 II FL0128.Ddf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4904 R7 AE 502A.0f Created by Independent Third Party: Yes 4904.4 I Wood -edge Steel Side -Hinged Door 18'-0" Opaque I/S Door w/ or w/o Sidelites Units Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +45.0/-50.0 Other: Evaluated for use in locations adhering to the Florida Building Code including the High Velocity Hurricane Zone, and where pressure requirements as determined by ASCE 7, Minimum Design Loads for Buildings and Other Structures, does not exceed the design pressures listed. 12'-0" x 8'-0" max nominal size. When large missile impact resistance is required, hurricane protective system is NOT required on opaque panels, but is required on glazed panels. See DWG- MA-FL0129-05. Certification Agency Certificate FL4904 R7 C CAC NI006110.02.odf Quality Assurance Contract Expiration Date 12/31/2020 Installation Instructions FL4904 R7 II FL0129.Ddf Verified By: -National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports FL4904 R7 AE 501A.odf Created by Independent Third Party: Yes 4904.5 I Wood -edge Steel Side -Hinged Door 18'-0" Opaque O/S w/ or w/o Sidelites Units hhps:l loridabuildng.orglpr/pr appdU.aspx?param=wGEVXQMDgtelulwHNbb$ScIO%2baWoLtMiTsl7(o1AO%3d ra 0(YJQ7?l?C SIDE -HINGED WOOD -EDGE STEEL DOOR UNIT 6 =8' DOUBLE DOOR WITH / WITHOUT SIDELITES CWERAL NOTES I EVALUATED FOR USE IN LOCATIONS AMICRINC TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES. DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS. BUT IS REQUITED ON GLAZED SIDEUTES. 3. 01 PIE HVHZ. FACTORY PRIMED DOORS MUST BE PAINIED IN ACCORDANCE WITH SECTION 2220 OF VIE FBC. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM EBA. S. PLASTICS TESTING OF UTE FRAME MATERIAL: TMT MCMIDUn. .-1. e SELF ICHITION TEMP ASTM 01929 740 T > 650 T RATE OF BURNING I AST" 0635 1 0.77 IN WN SMOKE DENSITY I ASTM D28/3 13.4% TENSILE STRENGTH- I ASTM 063E J.7.50% OIFF nLnY n 77 gHlnr,JYl114 450o HOURS x[NON ARC METHOD I 149' Ata. OWftL FRALIE 1TM 21' MAX 36.375" MAX. 01 0. PANEL WIDTH _ 37.5' MAX. W/ASTRAGAL I FRAME WIDTH n d m W h o we e to O n IF IT/ •I /i p1 00 00 00 00 I ®0 00 as as 00: :00 Lull00. 00 aasas11SINGLEDOOR UNIT DOUBLE ODOR UNIT Am -LE -MR -muff SINGLE ODOR- I V.NIT SINGLE DOOR UNI w/ IDEUTE_S MTN SIDELITE WITH SIDFUTE TASLE OF CONTENTS SHEET IIIDESCRIPTION I TYPICAL FLEVATIONS h GENERAL NOTES ANCHORING LOCATIQmg h DCTNLS 3 1ANCHORING LOCATIONS k DETAILS AOJLIpIpIoiLLMI CIS>awtcnTb: o e - -'y RImcATdBY. bleRota[_i„ DOUBLE DOOR Umff W/SID 1TES L0 o 00 U O Q 00 OTr_ j z 3C Q 2 4U C UUj U 0) V1 Lu 4r : eVy— st" N.T.S. atic. or. $MIS al.. m. KURT SALTHAZOR elwwc IIOQ FLORIDA P£ OIIG- w-nolaa 856533 r 3' yl '- SEE DETAIL 3. I ITS 3" c 3 G• 131JIat- 'E" 3 SEE DETAIL c" 1 I I 16" 6' 6' 6" 11 I S B D 6' 3' 6' 6' 3- c a 't x —I 3 1 S• — — S' 3' G' SEE DETAIL 6' W n SEE D' j f8 x 2-1/2" § 10 x 2" 18 x 2-1/2" 110 x 5/8" 18 x 2-1/2" 110 x I" 0 110 x S/8" I10 x 3/4" 10 x 2 . DETAIL " " STRA FRAME / DOOR ATTACH ASTRAGAL RETAINER BOLT DETAIL "D' DETAIL "C" STRIKE PLATE TO FRAME AS SHO VN. TYPICAL I AG 1PM mbIlAlO 0.9621 CftTxAmft l• rnn rra_L'y t. 37j' — a Wep i Lr IN WING THRESHOLD OUTSWING THRESHOLD I ' EE DETAIL C. 6' ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGAL 16 (1/S• TEMP. OASS) DON 993 W/ OPTIONAL R SUM S INSERTAU61. 11EE1 011 9MtYl SPACER1n" STEEL 6 x 1-1/2• POTS OW 995 rXIERIOB 21111h09 TYPICAL GLAZING OFTAIL a to O 00 U 6 Q 0 IDO RO W OQ W Z 2 t U a ^ r/1 g LJ s or SCC DUAL C' S1iT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SCALED BY LUIS R. LOMDS. PE FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE 10 WOOD SCREWS OR 3/16" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". 2. MULLIONS TO BE 2-1/2" X 4-3/8" STRUCTURAL GRADE FJ PINE ON CONTINUOUS HEAD AND SILL UNITS. BACK TO BACK JAMB UNITS JOINED WITH 1" X 1/2" LONG CORRUGATED FASTENERS LOCATED 3" FROM EACH END AND MAXIMUM 7" O.C. OR #10 X 2" FLAT HEAD WOOD SCREWS LOCATED 6" FROM EACH END AND MAXIMUM 12" O.C. 3. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2- MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 4. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 5. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 171 LBS. 3' I N N II I I to UI Y SEE OETNL S111. 2 o. W wAx02 C o r1 I 3- 6' cc OD Y r 3- 3-1 O topQ 0(r-i11II II III6' 6• I R to SO W a(5 o u NUzNrn 3 N o U, B Ot II II II II I 3 8 s o yI 3.6 6 I- 6 3' F— u 10b o 1. JKWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES 1 1.50' I— 1.25' woum! MIN 0.25' MIN • i CL JIs1H `u SHIM om 7 1I f)5 CL —I.Adit.M*IWO scut: M.T.S. CMtWi011 fib _ van 1. i c _ R y aft. or; SwS 0.teRnxe a¢_ ! auc. or TYPICAL WOOD BUCK TYPICAL MASONRY ouC-w-nol:s. ANCHOR INSTALLATION ANCHOR INSTALLATION I _ _ S"MT 3 or 3 NOTICE OF PRODUCT Company: Masonite International 1955 Powis Road West Chicago, IL 60185 Product: Wood -Edge Steel Opaque lnsi w/Wood Frame unless noted) Specification: TAS 201/202/203 CATION n Certification No.: N1006110.01 Certification Date: 07/23/2005 Expiration Date: 12/31/2020 Revision Date: 11/21/2014 or Outswing Door w/ and w/o Non -impact Rated Sidelites The "Notice of Product Certification" is only valid if the NAMI Certification Label has beep applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certificationlcriteria has been satisfied. This product has been approved for listing within NAMI's Certified Product Listing at www.Nonticertification.coni. NAMI's Certification Prlogram is accredited by The American National Standards Institute (ANSI). Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number & Outswine Opaque Size Pressure Pressure Rated Comments X I/S Opaque 3'0" x 6'8" 76476 2.86 psf Yes NCTL-210-2929-1 Single I Maximum Panel Size: 3'0" x 61" Anchor Detail-MA-FLO 128-OS X O/S Opaque 3'0" x 6'8" 76/-76 8.25 psf Yes NCTL-210-2929-I Single I Maximum Panel Size: 3'0" x 61" Anchor Dctail-MA-FLO129-05 XX 1/S Opaque 6'0" x 61" SS/-55 2.86 psi' Yes NCTL-210-2930-1 Double I Maximum Panel Size: 3'0" x 6'8"/Sidelitc: 3'0" x 6'8" Anchor Dctail-MA-FL0128-0S XX O/S Opaque 6'0" x 61" 55/-55 8.25 psf Yes NCTL-210-2930.1 Double I Maximum Panel Size: 3'0" x 6'8"/Sidclitc: 3'0" x 6'8" Anchor Detail-MA-FL0128.05 XO/OX 1/S Opaque Door 6'0" x 61" 551-33 2.86 psf Door -Yes NCTI,210.2930-1 Single w/Sidelite Glazed Sidelite Sidclitc-No Maximum Panel Size: 3'0"x 6'8"/Sidelite: 3'0" x 6'8" Anchor Detail-MA-FLO128-05 XO/OX O/S Opaque Door 6'0" x 61" 55/-55 8.25 psf Door-Ycs NCTL-210-2930.1 Single w/Sidelites Glazed Sidelite I Sidelite-No Maximum Panel Size: 3'0" x 6'8"/Sidelitc: 3'0" x 6'8" Anchor Derail-MA-171.0128-03 OXO 1/S Opaque Door 9'0" x 6'8" 551-55 2.86 psi' Door -Yes NCTL-210.2930.1 Single w/Sidelites Glazed Sidclitcs I Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidclitc: 30" x 6'8" Anchor Dctail-MA-FLOI28-05 OXO O/S Opaque Door 9'0" x 61" 551-55 8.25 psf Door -Yes NCTL-210-2930-1 Single w/Sidclitcs Glazed Sidelites Sidclitcs-No Maximum Panel Size: 3'0"x 6'8"/Sidelite: 3'0" x 61" OXXO I/S Opaque Doors 12'4" x 6'8" 55/-55 2.86 psf' Doors -Yes Anchor Detail-MA-FLO128-03 NCI'L-210-2930-1 Doublc w/Sidelites Glazed Sidclitcs Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidclitc: 3'0"x 6'8" OXXO O/S Opaque Doors 12'4" x 61" 551-55 8.25 psf' Doors -Yes Anchor Derail-MA-171-0128-05 NCTL-210-2930-1 Double w/Sidclitcs Glazed Sidclitcs I Sidelites-No Maximum Panel Size: 3'0" x 6'8"/Sidclitc• 3'0" x 6'8" Anchor Detail-MA-FLO128-05 National Accreditation & Management Institute,11104794 George Washington Memorial Highway/1-laves VA 23072 Tel: (804) 684-5124/Fax: (804) 684-5122 NAMI AUTHORIZED SI 1 NATURE: Luis R. Lomas P. E- 1 of2 1432 Woodford Rd. Manufacturer: Masonite Lewlsw1/ e. NC 27023 Report #: 504A 336- 945.9695 Date: 12/29/09 Product: Single Door 3'x6'8• Scone: This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the product described herein. These calculations comply with requirements of the Florida Building Code. Drawings verification: This analysis verifies anchoring for the following drawings: DWG- MA-FLO120-05 DWG-MA-FLO130-05 DWG-MA-FLO153-06 DWG-MA-FLO168-07 DWG- MA-FLO122-05 DWG-MA-FLO132-05 DWG-MA-FLO155-06 DWG-MA-FLO170-07 DWG- MA-FLO124-05 DWG-MA-FLO134-05 DWG-MA-FLO156-06 DWG-MA-FLO172-07 DWG- MA-FLO126-05 DWG-MA-FLO140-05 DWG-MA-FLO160-07 DWG-MA-FLO174-07 DWG- MA-FLO128-05 DWG-MA-FLO151-06 DWG-MA-FLO162-07 DWG-MA-FLO175-07 Anchors to be auallfied: 1. # 10 Wood screw, for installation in wood frame substrates. 2. 3/16• ITW Tapeon, for masonry installation Anchor capacity in shear condition: Fastener type, #10 wood screw (NOS 2005,11.3) Side member: Douglas Fir -Lurch Main member: Spruce -Pine -fir Side member thickness: t, = 1.000 in Main member thickness: t• = 1.500 in Side member dowel bearing strength: Fes : 4.650 psi Main member dowel bearing strength: Fir, n 3.350 psi Minimum required penetration, 1.330 in Screw bending yield strength: Fry o 80,000 psi Duration Factor: ce = 1.6 Tabulated lateral design value: Z• 107.0 Ibs Allowable Design Value: Z'= 171 Ibs/anchor Mode IV Fastener type: 3/1V ITW Topeon N.O.A.07-1126.10 Substrate: Hollow block Minimum embedment: 1.25 in Minimum edge distance: 1.13 in Minimum C to C spacing: 2.25 In Tabulated shear design value: Z c 112 lbs Actual C To C spacing: 3.00 in Minimum edge distance: 2.63 in C to C spacing factor. 1.00 Tabulated shear design value: Z = 197 Ibs Actual edge distance: 2.50 in Design• wlue•perimerpolotion. Z=-189'Ibs Allowable Design Value: Z'= 189 lb her Minimum anchor capacity: 171lbs/anchor Note: Anchors with the least capacllir Is used for calculations to qualify anchors with higher capacity. Anchor calculations. minimum required anchors Pressure against stops with bump threshold: 36. 38 Design pressure: 85.0 psf f _ f Max. Anchor AreaLoadInd. At- Zone z O.C. Cap. Load Result i 79.25 (ft) (Ibs) (in) (in) ( Ibs) Q1Y (Ibs) r A2 At 2.3 195 N/A N/A 171 2 98 OK At Az 7.7 656 6.00 18.00 171 5 131 OK Single. Pressure away from stops: 36. 38 Design pressure: 85.0 psf Area Load Ind. Max' Anchor Al I At Zone z O.C. Cop. Load 10K t 79. 25 (in) (Ibs)Itt Ibs) At 10.0 851 6.00 18.00 171170 1 I I I Ll0 i NJ •'''• q% r G E N SF ftir 4.- TATE0 51 •= Jo OF • ` i Luis R. Lomas P.E. jO': , Z 0 RIOP • FL No.: 62514 e tS • .. • G 1f7/2010 Lu/s R. Lomas A E. 1432 Woodford Rd. Manufacturer Masonite Lewisvlrle, NC 27023 Report #: 504A 336-945.9595 Date: 12/29/09 Single. Pressure against stops with saddle threshold: 11 36.38 Design pressure: 85.0 psf i 79.25 A2 A2 i Zone Area zft) Load pbs) Ind. in) Max. O.C. in) Anchor ResultCap. Ibs) QtY Load Ibs) Ai 2.3 195 N/A N/A 171 2 98 OK AZ 8.9 753 6.00 18.00 171 5 151 OK Anchor Locations: 36.38 -- 18.19I 6.00 TYP. = 6.00 TYP. Note: Anchor locations indicated in this document are the minimum required for the described product exposed at the design pressure indicated herein. - 2of2 Vt 1 ILO i,/ E IV 51- j--4 - TAT OF • OR1DP Go, Luis R. Lomas P.E. FL No.: 62514 1/7/2010 job Address: 610 W. 9th Steet MAR 3 0 2017 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: ( 17— / to Documented Construction Value: S. 835,000 Historic District: Yes No Parcel ID: 25-19-30-512-1009-0060 & 25-19-30-512-1009-0080 Residential Commercial El Type of Work: New El Addition Alteration Repair Demo Change of Use Move Description of Work: New 16 Unit Apartment Complex Plan Review Contact Person: Bob Horian Title: Phone: 407-688-7644 Fax: 407-688-7920 Email: bob(cD-suncorprops+rties.com Property Owner Information Name Coastline Park LLC Phone: 407-322-0126 Street: 815 S. French Ave Resident of property? : City, State Zip: Sanford, FL 32771 Contractor Information Name RLH Construction Phone: 407-330-7104 Street: PO Box 0625 City, State Zip: Sanford, FL 32772 State License No.: CGC 1512297 Architect/Engineer Information Name: WDS Design Group Street: 2612 Herbison Dr. City, St, Zip: Orlando, FL 32810 Phone: 407-298-4679 40•:::.. E-mail: wshaffer8Qcfl.rr.com Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 511 Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 3/27/17 Signature of Owner/A Date RT Hillery Print caner/Agent's Name Signature ofl6 tF6( Date f o aar -& Notary Public State of Florida My Commission Expires 11/27/2020 Owner/ 6® gi0q_MyGM19D own to Me of Produced ID y( Type l Oi'we 0 1.1 Z 3/ 27/17 Signature of Contractor/Agent Date J. M. Hillery Sr. Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/ Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps, Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION FIRE PLAN REVIEW SERVICE FEES PHONE: 407.688.5052 FAX: 407.688.5051 DATE: PERMIT NUMBER: -7, t / BUSINESS/PROJECT NAME: ADDRESS: (., /0 CONTACT NAME: Y-S-1-i PHONE:\`M / ) (jg > PLAN REVIEW INFORMATION CONSTRUCTION [ ]C/O [ ] FIRE ALARM [ ] FIRE SPRINKLER [ ] HOOD [)PAINT BOOTH [ ]TANK DOES 20% REDUCTION IN FIRE IMPACT FEES APPLY: YES NO TOTAL FEES: COUNTY OF SEMINOLE $ 9 IMPACT FEE STATEMENT ' / /q , po STATEMENT NUMBER: 17100003 DATE: September 26, 2017BUILDINGAPPLICATION #: 17-10000318' BUILDING PERMIT NUMBER: 17-10000318 UNIT ADDRESS:4:9TH ST 610 SET 2'j 201725-19-30-SAG-1009-0060 , TRAFFIC ZONE:022 JURISDICTION: ---- SEC: TWP: RNG: SUF:-D-(6 PARCEL: SUBDIVISION: TRACT: PLAT BOOK: PLAT BOOK PAGE: BLOCK: LOT: OWNER NAME: ADDRESS: APPLICANT NAME: COASTLINE APARTMENTS LLC ADDRESS: 815 S FRENCH AVE SANFORD FL 32771 LAND USE: DEMO 4 SFR REBUILD APT BLDG TYPE USE: WORK DESCRIPTION: CITY-SANFORD SPECIAL NOTES: 610 W. 9TH ST L DEMO 4 1989 SFR'S / REBUILD 16 UNIT APT BLDG FEE BENEFIT RATE TYPE DIST SCHED UNIT RATE CALC UNITS UNIT TYPE TOTAL DUE ROADS-ARTERIALS CO -WIDE ORD Apartment* ROADS- COLLECTORS N/A 435.00 16.000 dwl unit 6,960.00 Apartment* 00 16.000 dwl unit FIRE RESCUE N/A 00 LIBRARY CO -WIDE ORD 00 Apartment* 54.00 16.000 dwl unit 864.00SCHOOLSCO -WIDE ORD KKSSPAAurtment* N/A 2,100.00 16.000 dwl unit 33,600.00 LAW ENFORCE N/A 00 DRAINAGE N/A 00 CREDIT FEES: C 00 SCI LIBRARY Single Family Housing 54.00 4.000 dwl unit 216.00- SCI SCHOOLS R Single Family Housing 2,315.00 4.000 dwl unit 9,260.00- SCI ROAD ARTERIALS C Single Family Housing 705.00 4.000 dwl unit 2,820.00- AMOUNT DUE 29,128.00 STATEMENT LRECEIVEDBY: T f,J SIGNATURE: -7 PLEASE PRINT NAME) DATE: T` 7 NOTE TO RECEIVING SIGNATORY/APPLICANT: FAILURE TO NOTIFY OWNER AND ENSURE TIMELY PAYMENT MAY RESULT IN YOUR LIABILITY FOR THE FEE. *** DISTRIBUTION: 1-BLDG DEPT 3-APPLICANT '(q(po_ -Zg 2-FINANCE 4-LAND MANAGEMENT 4pag(n NOTE** TIC - % L(-O = SEMINOLEACOUNTYIROADED THFIRE_/_RESCIS UE, STATEMENT AND/OR EDUCATIONAL THE ISSUANCE OF A BUILDING PERMIT. PERSONS -ARE. -ALSO -ADVISED --THAT ANY RIGHTS OF THE APPLICANT. OR OWNER. OF -OCCUPANCY OR OCCUPANCY. TH$ REQUEST FOR t'v11in;5 yr XULAZ5 UUVERNING APPEALS MAY BE PICKED UP OR REQUESTED, FROM THE PLAN IMPLEMENTATION OFFICE: 1101 EAST FIRST STREET, SANFORD FL, 32771; 407-665-7356. PAYMENT SHOULD BE MADE TO: SEMINOLE COUNTY OR CITY OF SANFORD BUILDING DEPARTMENT 1101 EAST FIRST STREET SANFORD, FL 32771 PAYMENT SHOULD BE BY CHECK OR MONEY ORDER AND SHOULD REFERENCE THE COUNTY BUILDING PERMIT NUMBER AT THE 'SOP LEFT OF THIS STATEMENT. THIS STATEMENT IS NO LONGER VALID IF A BUILDING PERMIT IS NOT*** ISSUED WITHIN 60 CALENDAR DAYS OF THE RECEIVING SIGNATURE DATE ABOVE DETAIL OF CALCULATION AVAILABLE UPON REQUEST. CALL 407-665-7356. ten \° J I 11 D ECEIVE MAR 3 0 2017 CITY OF SANFORD BUILDING & FIRE PREVENTION BY• _ PERMIT APPLICATION rWe . Application No: Vto y Documented Construction Value: Job Address: 610 W. 9th Steet Historic District: Yes No Parcel ID: 25-19-30-512-1009-0060 & 25-19-30-512-1009-0080 Residential Commercial El Type of Work: New x Addition Alteration Repair Demo Change of Use Move Description of Work: New 16 Unit Apartment Complex Plan Review Contact Person: Bob Horian Title: Phone: 407-688-7644 Fax: 407-688-7920 Email: bob(cD-suncorproperties.com a Property Owner Information Name Coastline Park LLC Phone: 407-322-0126 Street: 815 S. French Ave Resident of property? : City, State Zip: Sanford, FL 32771 Contractor Information Name RLH Construction Phone: 407-330-7104 Street: PO Box 0625 City, State Zip: Sanford, FL 32772 State License No.: CGC 1512297 Architect/Engineer Information Name: WDS Design Group Street: 2612 Herbison Dr. City, St, Zip: Orlando, FL 32810 Bonding Company: Address: 7 Phone: 407-298-4679 Mortgage Lender: 7 --/4 %- Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST, INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as o -that date: 511 Edition (2014) Florida Building Code Revised: 5/ v•J /J A I+ L Permit Application 10tQ ' V/ f50 G 4ulo Z 5 •iq•30•i12 0 L 0• 0• 0• 11086.29 x 12• _ 139035.48 0 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: 1 certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. zL r, Z(f!t 3/27/17 Signature of Owner/ADate BT Hillery Print weer/Agent's Name 3 z 5 17 Signs I Date A Notary Public State of Florida My Commission Expires 11/27/2020 Owner/ 6 re@Tttown to Me o ZProduced IDTeoJLOr',J Z, 3,/27/17 Signat of Contmctor/Ageth V Date J. . Hille Sr. Pri C ntractor/Agent's Name Signature of Notary -State of Florida Date o ANNETTE BLAND a Notary Public - Slate of Florida sir , fir Commission 0 GG 060623 C tr'bBStt i gehVijomm. E>e d f & n to Me or Pr ePC UT 1 UP y BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical E?"' Mechanical Plumbing Gas Roof Construction Type: yd Occupancy Use: X-.2 Flood Zone: _ Total Sq Ft of Bldg: //F Yz Min. Occupancy Load: of Stories: d,y,,_y- New Construction: Electric - # of Amps l Plumbing - # of Fixtures 1( Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: WASTE WATER: ENGINEERING: FIRE: BUILDING:' % COMMENTS: Revised: June 30, 2015 Permit Application U.11, -.t I MAR 3 0 2017 CITY F SANFORD BUILDING & FIRE PREVENTION BYPERMIT APPLICATION Application No: Documented Construction Value: $ 835,000 Job Address: 610 W. 9th Steet Historic District: Yes No Parcel ID: 25-19-30-512-1009-0060 & 25-19-30-512-1009-0080 Residential Commercial El Type of Work: New El Addition Alteration Repair Demo Change of Use Move Description of Work: New 16 Unit Apartment Complex Plan Review Contact Person: gob Horian Title: Phone: 407-688-7644 Fax: 407-688-7920 Email: bob0suncorproperties.com Property Owner Information p Name Coastline Park LLC Phone: 407-322-01 6 4- -- Street: 815 S. French Ave Resident of property? : City, State Zip: Sanford, FL 32771 Contractor Information Name RLH Construction Phone: 407-330-7104 Street: PO Box 0625 Fax: 407-328-8055 City, State Zip: Sanford, FL 32772 State License No.: CGC 1512297 Architect/ Engineer Information Name: WDS Design Group Street: 2612 Herbison Dr. Phone: 407-298-4679 1 110* ::•. City, St, Zip: Orlando, FL 32810 E-mail: wshaffer8Qcfl.rr.com Bonding Company: Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5"Edition (2014) Florida Building Code Revised: June 30, 2015 ' / I ' ! 15y,50 Permit Application 5/ . 5137, s0 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 3/27/17 Signature of Owner/ADate ET Hillery Print caner/Agent's Name Wa. 3IL9 f7 SignatureofiIJ6(Fl6fflfiCr"ryeCQDate o P• r'k Notary Public State of Florida My Commission Expires 11/27/2020 Owner/ 61DSbnM 6@aWbJown to Me o Produced ID ' i( Type of ID L Ori- 3/27/ 17 Signature of Contractor/Agent Date J.M. Hillery Sr. Print Contractor/ Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Construction Type: Total Sq Ft of Bldg: /y 6? J-,2 New Construction: Electric - # of Mechanical [r Plumbinge Gas Roof 0— Use: /r'- Z Flood Zone: Occupancy Load: I Fire Sprinkler Permit: Yes [INo # of Heads of Stories: o N Plumbing - # of Fixtures Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: -47 WASTEWATER: ENGINEERING: COMMENTS: FIRE: BUILDING: Revised: June 30, 2015 Permit Application important r-otnts The BVD is not intended to apply to alterations or repairs to existing buildings. Because the scope of alterations or repairs to an existing building varies so greatly, the Square Foot Construction Costs table does not reflect accurate values for that purpose. However, the Square Foot Construction Costs table can be used to determine the cost of an addition that is basically a stand-alone building which happens to be attached to an existing building. In the case of such additions, the only alterations to the existing building would involve the attachment of the addition to the existing building and the openings between the addition and the existing building. For purposes of establishing the Permit Fee Multiplier, the estimated total annual construction value for a given time period (1 year) is the sum of each building's value (Gross Area x Square Foot Construction Cost) for that time period (e.g., 1 year). The Square Foot Construction Cost does not include the price of the land on which the building is built. The Square Foot Construction Cost takes into account everything from foundation work to the roof structure and coverings but does not include the price of the land. The cost of the land does not affect the cost of related code enforcement activities and is not included in the Square Foot Construction Cost. Square Foot Construction Costs 9. b. Group (2015 International Building Code) IA IB IIA IIB IIIA IIIB IV VA VB A-1 Assembly, theaters, with stage 233.95 225.89 220.42 211.39 198.92 193.15 204.70 181.63 174.97 A-1 Assembly, theaters, without stage 214.40 206.35 200.88 191.84 179.53 173.76 185.16 162.23 155.58 A-2 Assembly, nightclubs 182.86 177.56 173.06 166.05 156.54 152.22 160.22 141.73 136.94 A-2 Assembly, restaurants, bars, banquet halls 181.86 176.56 171.06 165.05 154.54 151.22 159.22 139.73 135.94 A-3 Assembly, churches 216.47 208.41 202.95 193.91 181.79 176.02 187.23 164.50 157.85 A-3 Assembly, general, community halls, libraries, museums 180.57 172.51 166.04 158.00 144.89 140.11 151.32 127.59 121.94 AA Assembly, arenas 213.40 205.35 198.88 190.84 177.53 172.76 184.16 160.23 154.58 B Business 186.69 179.79 173.86 165.19 150.70 145.02 158.70 132.31 126.48 E Educational 197.52 190.73 185.77 177.32 165.32 156.97 171.23 144.39 140.26 F-1 Factory and industrial, moderate hazard 111.86 106.71 100.58 96.68 86.77 82.81 92.61 72.75 68.09 F-2 Factory and industrial, low hazard 110.86 105.71 100.58 95.68 86.77 81.81 91.61 72.75 67.09 H-1 High Hazard, explosives 104.68 99.53 94.40 89.50 80.80 75.84 85.43 66.78 N.P. H234 High Hazard 104.68 99.53 94.40 89.50 80.80 75.84 85.43 66.78 61.12 H-5 HPM 186.69 179.79 173.86 165.19 150.70 145.02 158.70 132.31 126.48 1-1 Institutional, supervised environment 187.63 181.26 176.01 168.60 155.33 151.11 168.69 139.15 134.82 I-2 Institutional, hospitals 314.17 307.27 301.34 292.67 277.18 N.P. 286.18 258.79 N.P. I-2 Institutional, nursing homes 217.67 210.77 204.84 196.17 182.68 N.P. 189.68 164.29 N.P. 1-3 Institutional, restrained 212.42 205.52 199.59 190.92 177.93 171.25 184.43 159.54 151.71 14 Institutional, day care facilities 187.63 181.26 176.01 168.60 155.33 151.11 168.69 139.15 134.82 M Mercantile 136.25 130.95 125.45 119.44 109.43 106.11 113.60 94.63 90.83 R-1 Residential, hotels 189.35 182.99 177.74 170.33 156.80 152.58 170.42 140.62 136.29 R-2 Residential, multiple family 158.84 152.48 147.23 139.81 127.05 122.83 139.91 110.87 106.54 R-3 Residential, one- and two-family ° 148.17 144.14 140.42 136.90 131.89 128.41 134.60 123.40 116.15 R-4 Residential, care/assisted living facilities 187.63 181.26 176.01 168.60 155.33 151.11 168.69 139.15 134.82 S-1 Storage, moderate hazard 103.68 98.53 92.40 88.50 78.80 74.84 84.43 64.78 60.12 S-2 Storage, low hazard 102.68 97.53 92.40 87.50 78.80 73.84 83.43 1 64.78 59.12 U Utility, miscellaneous 80.38 75.90 71.16 67.61 60.99 57.00 64.60 48.23 45.92 a. Private Garages use Utility, miscellaneous b. For shell only buildings deduct 20 percent c. N.P. = not permitted d. Unfinished basements (Group R-3) = $21.00 per sq. ft. r eEn+o e earnr, aa,, Parcel: 25-19-30-5AG-1009-0060 Owner/Address: GODINHO, ANSELMO & AUGUSTA 1882 REX CT LONGWOOD, FL 32750-3796 Situs: 610 W 9TH ST SANFORD, FL 32771 Facility Code: Facility Name: Subdivision: 1999 Parcel Detail Sheet 09/26/2017 09:54 AM Legal: LOTS 6 + 7 BLK 10 TR 9 TOWN OF SANFORD PB 1 PG 62 Exemption Code Description Granted Assessment Information Prior Year RE Appraised Addition Total Land Value 10,039 10,039 Extra Features Building Value 51,258 51,258 Cost/Market Just Value 61,282 61,297 0.0 61,297 0.0 Income Just Value Correct Assd/Admin Value Classified Value . SOH Adjustment Total Assessed Value 61,282 61,297 0.0 61,2971 0.0 Extra Feature Information Code Description Units RCN jOvdjAdjjAct1EffjCapj Ap rVal Bdg Total: Unknown S' 5 20V 25-19-30-SAG-1009-0060 Site Date: O1/O1/2017 Building Date: 01/21/2015 Land Date: 03/09/2015 Tax Di r 4: SANFORD- 17-92 REDVDSTg DOR Use esc: 01: SINGLE FAMILY CPI: 1.60 Market Area: 01 Nbad Comm: E&I Num: Pet Num: Demo: Income Ind: Income Ltr: Taxable Information Taxing Authority Description Millage Values Assessed Exempt Taxable 0100 COUNTY GENERAL FUND 0 61,297 61,297 0400 SCHL SCHOOL 0 61,297 61,297 1000 CITY SANFORD 0 61,297 61,297 1200 JSJWM 1 01 61,2971 61,297 9800 ICOUNTY BONDS 1 01 61,2971 61,297 Land Information Cd Ag Mkt Rate Ag Rate Area Fmt D/Tft264h A r Value Ad) Reason Just Value AF 65 0 0 117 1 10,039 1 10,0391Total: 10,039 10,039 Sales Information Code Deed Description Date Book Amount WI QC PCC SQ WD WARRANTY DEED 02/O1/2017 08869 220,000 V 02 SQ WD WARRANTY DEED 12/O1/2004 05557 0422 110,000 1 02 SQ WD WARRANTY DEED 05/O1/1998 03428 63,400 1 03 SQ WD IWARRANTY DEED 02/01/1985 101617 0477 71,300 I 00 SU QD JQUIT CLAIM DEED 02/01/1985 01617 0476 100 1 loo SU QD IQUIT CLAIM DEED 07/01/1980 01287 0992 100 I 100 Date I Notes 17 08:54 AM ZONED: GC-2 BUT IN PLANNING STAGES TO BUILD 16 UNIT APARTMENT COMPLEX 1 Pag-e 1 oAS CVA CIP16 1999 ParcelDetail Sheet 2s- 1930-SAG-1009-0060 Site Date: Ol/Ol/2017 09/ 26/2017 09:54 AM Building Date: 01/21/2015 Land Date: 03/09/2015 Perm0nf6rmation_ Statu toe^-- M VR 1- ,VaeT st.pOo07 D S 04/07/2016 01072 2017 4,210 DEMO. 2 FAMILY HOMES. PAD PER PERMIT: 610 W 9TH ST 07 D S 07/19/2007 02753 2008 1,S00 REPLACE ELECTRICAL 07 D S 07/17/2003 02526 2004 1,000 DEMOLISH SFR 07 D S 05/01/1999 1 02215 1999 200 REPLACE WINDOWS; 6101/2 W 9th ST Is_ Page 2 of 5 PRAISER gr..+o e oasnr. aa Parcel: 2519305AG10090060 Base Area'k-911)t dg Adj SgFt: 908 Bldg Type:.,O1xSINGLE*FAK4IbY*1 Living Area:a89,10 Act Yr Bit: 1930 Adj Rate: 30.83 Eff Yr Bit: 0 TO Points:.83 Cap Y . 1930 Adj Points:.83 Arch Mo Base Rate: 33.75 NBHD Fac: 1 RCN: 27,994 DEPR-RCN: 12,947 Apnpnoavesw Seq 100 Code Actual= 17 Year fl 1 OSPU:Unknown 56Totals56 1999 Parcel Detail Sheet Ovd Code: 0 Dep %: 46.25 Floors: 1 Fixtures: 3 Height: Rooms: Bedrooms: Bathrooms: 09/26/2017 09:54 AM 25-19-30-SAG-1009-0060 Site Date: 01/01/2017 Building Date: 01/21/2015 Land Date: 03/09/2015 ru ral-_.. Coley Eleme'` Description s . Z tMM?;~,.7' ^'. VA KrP.01Ms0 O Ir 0001 PIERS 4 0103 WD W/O SUB 5 0204 SIDING GRADE 3 31 0300 NONE 0 0402 GABLE/HIP 10 0501 ROLL-TOP ROOFING 2 0608 PINE/SOFT WOOD 4 0705 MIN WALLS 20 0802 W/F FURN 2 0903 AVERAGE 5 Total Points i :' 3 10-11 41 Page 3 of 5 rFln SER 1999 Parcel Detail Sheet 25-19-30-SAG-1009-0060 I Site Date: 01/01/2017 09/26/2017 09:54 AM Building Date: 01/21/2015 Land Date: 03/09/2015 Parcel: 2519305AG10090060 Base Area:.952%W Bldg No: 2 Adj SgFt: 1,126 Bldg Type: 01:.5_IN6LE FAAAILY Living Area: 9 Act Yr Blt: 1946 Adj Rate: 31.75 Eff Yr Blt- 946 TO Points:.87 Cap 1946 Adj Points:.87 Arch Mo 1 Base Rate: 33.75 NBHD Fac: RCN: 35,751 DEPR-RCN: 23,685 A enda es Code Actual§Md-jo Year FL 1 OEPF: Unknown10EPU: 120 96 2 Unknown 130 78 Lotals 250 174 Ovd Code: 0 Dep %: 66.25 Floors: 1 Fixtures: 3 Height: Rooms: Bedrooms: Bathrooms: Striictural_Elements_ _ 0001 PIERS 4 0103 WD W/O SUB 5 0204 SIDING GRADE 3 31 0300 NONE 0 0402 GABLE/HIP 10 0500 CORRUGATED ROOF 5 0608 PINE/SOFT WOOD 4 0704 WOOD WALLS 23 0800 NONE 0 0903 AVERAGE 5 Total Points RY; °fix' _ . k'7,v"e Page 4 of S P/ IPPRAISER Parcel: 2519305AG10090060 Base Area: JVI)P Bldg No:qw Adj Sgft: 800 Bldg Type: '01 gSINGI!ETFA MI' LY Living Area: 720 Act Yr Blt: 1941 Adj Rate: 30.47 Eff Yr "It: 41 TO Points:.81 Cap Yr 1941 Adj Points:.81 Arch Mo i Base Rate: 33.75 NBHD Fac: 1 RCN: 24,376 DEPR-RCN: 14,626 A ends es Code Actual Adj Year FL 1 OEPU:Unknown 1 133 80 To_tals 133 80 1999 Parcel Detail Sheet Ovd Code: 0 Dep %: 60.00 Floors: 1 Fixtures: 3 Height: Rooms: Bedrooms: Bathrooms: 09/26/2017 09:54 AM 25-19-30-SAG-1009-0060 Site Date: 01/01/2017 Building Date: 01/21/2015 Land Date: 03/09/2015 Stiuctural_Elements _ Code Desc Iption w`: 0001 PIERS 4 0103 WD W/O SUB 5 0204 SIDING GRADE 3 31 0300 NONE 0 0402 GABLE/HIP 10 0501 ROLL-TOP ROOFING 2 0608 PINE/SOFT WOOD 4 0705 MIN WALLS 20 0800 NONE 0 0903 AVERAGE 5 Total P.olnts oiij r 81', Page 5 of 5 APPER DELETED ••• Parcel: 25-19-30-512-1009-0080 Owner/Address: REFERENCE, ONLY Situs: Facility Code: Facility Name: Subdivision: MARTINS ADD A C 015 Parcel Detail Sheet n 09/26/2017 09:58 AM Legal: ASSESSED WITH 25-19-30-SAG-1009-0060 LOTS 89+1OBLK10TR9 Exemption Code. I Description Granted Assessment Information Prior Year RE Appraised Addition Total Land Value Extra features Buildin .Value Cost/Market Just Value. Income lust Value Correct Assd/Adman Value . Classified:Value SOH Ad usiinent N6ri=HX A8 usirhent P&G'Ad•ustmeni - Total Assessed,Val'ue' 25-19-30-512-1009-0080 Site Date: 06/08/2009 Building Date: 01/01/2004 Land Date: 11/05/1975 Tax District: S4: SANFORD-17-92 REDVDST DOR Use Desc: N.: Unknown CPI: 80 Market Area: 69 Nbad Comm: E&I Num: Pet Num: Demo: a Ind: 7 Income Ltr: Taxable Information ' Taxing Authority Descri on Millage Values _ Assessed Exempt Taxable' O100 COUNTY GPCERALFUND 0 0400 SCHL SCHOOL 0 5000 CI ANFORD 0 1200MWM 1 0 9800 COUNTY BONDS 1 0 Larid Information . Ag Mkt'.Rite Ag Rate Area• Firit D/T Depth A r Value Ad Reason Just Value., 1Cd. AL I 1 01 1 11 01 1 0 1 Total: Extra Feature lnfortnation I: Sales Information . d I Code' Desctiption ` : '• Ovd I Adj I Act I Eff I CaV A prVal I Bdg Code Deed Descri tton Date Book Page Amount . V/1 QC PCC Units RCN Total:"—` G 16 25-19-30-5AG-1009-0060 25-19-30-SAC-1009-0060 TRY 98 15 7e, 1!CT;,96 mat neat CODINNO ANSELMO 6 AUCUSTA i'LEC:,LOT8..fi'.r,;;T.r::8LK10' TR 9 610 M NINTH ST 88 ROA OS13 BLOC s 2: 623 8TN ST N IN 30-19-31 addl q.TtO,MN`O,F 8,ANFORD NYS add2 1992 REX CT css LONCMOOD, FL 32750 3T96 609 ATM ST M PB..'1P6 f 62 SAND PSr,1 9;.30 5.1,21.1;0,09,M0090 _: •, pad SANFORD, FL 327T1 LOT8: •8 9 + 10''BLK •1'0 TR; .9{ td do;? ekt demo (-exaps------> nbad status int% act blda-date land 1.00 IMPROVED 50 P 33 08149? 30 date do -date ti nr VAH 051393 NOR 0?0299 - 54 0:1: 01 10 Amendment-10 1:9.97 Re-A1999 ad --%--- Additions ex _---___-- TotaBl 8 ___ Larid•'V'al•u 1°0039 /0039 10039 a SFe tu'o safiii-Wldd•nas- V•aelu-t 50650 51243 S1243 Income.. V•a lue«.., Totfa l" Just)AV:a.00 06.9914 61282 .9 61282 .9 Coe' riet AssdeAdmin V Classified Value Amend. 10 Ad,lust.m9n;t,„_ Tofs: l: 'Ass.rs"d; VaiVut 60689 _: 61292 .9 61282 .9 1. 70% Amend 10 C&P LAND ------ ---- ----- ---- ---------------------------> Code Land At AS At . .Ars.a t Dep,t h-,- Value %Ad) oud Reason AF 65 0 :1_?,00,0.P6,^,j 10039 Tot Just Val: 10039 Tot Cl s Val. 10039 t----------------- SALES -------- ------ ----> t-------------------- EXTRA FEATURES - ------ ------- Type Date Hook Pats Aat VI Pcd Ln Code Dose Area RCN Oud Hlt/Eff-'Now Dtpr-RCN Bid SO MD 990501 03429 1?24 63400 1 C•3 Tot RCN: Tot DEP RCN: SO MD 850201 0161? 04?? MOO I E O SUD5007101992 10i O. 0297 00IOi O i r - CIO77 cn f :`3 :;pcn FORM 14405-2014 1i-q f PERMIT # i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical Inner Unit Builder Name: RLH Construction Street: 610 West 9th Street Permit Office: City of Sanford City, State. Zip: Sanford, FL , 32771 Permit Number. Owner. Typical Inner Unit Jurisdiction: 691500 Design Location: FL, Orlando County:: Seminole (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (448.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 448.00 ft° 3. Number of units, if multiple family 1 b. N/A c. N/A R= ft' R= ft' 4. Number o/ Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (777.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 777.00 ft° 6. Conditioned floor area above grade (ft') 777 b. N/A R= ft' Conditioned floor area below grade (ft3) 0 c. N/A x R= ft' 7. Windows(40.0 sgft.) Description Area 11. Ducts a. Sult-Attic, Ret: Attic, AH: Attic R ft' 6 225 a. U-Factor. Dbl, U=0.33 40.00 ft' SHGC: SHGC=0.27 b. U-Faclor. N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:15.00 c. U-Factor. N/A ft: SHGC: d. U-Factor. N/A fe 13. Heating systems Electric kBtu/hr Efficiency a. Heat Pump 17.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems 8. Floor Types (777.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 777.00 ft° I b. Conservation features EF: 0.650 b. N/A R= ft' None a -N/A R= ft' 15. Credits None Glass/Floor Area: 0.051 Total Proposed Modified Loads: 25.16 PASSTotalBaselineLoads: 26.68 1 hereby certify that the plans and specifications covered by Review of the plans and ST,12 this calculation are in compliance with the Florida Energy specifications covered by this 0 v Code.-- calculation indicates compliance y '. r = .e with the Florida Energy Code. n+,,,'^••. } s O PREPARED BY: _. Before construction is completed DATE: _.._-..-_ Q3-17l17 _ -__ __. " this building will be inspected for 09 compliance with Section 553.908 1 hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'pD WE OWNER/AGENT:-_ . _. -_. _...._.- BUILDING OFFICIAL: -. . DATE: _ ._ _. ...... _ .. _.- DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1017 11:56 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 x-, AfT PERMIT FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0317109 Typical End Unit Builder Name: RLH Construction Street: 610 West 91h Street Permit Office: City of Sanford City, State, Zip: Sanford, FL, 32771 Permit Number: Owner: Typical End Unit Jurisdiction: 691500 Design Location: •' FL, Orlando County:: Seminole (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (696.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.0 696.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. N/A R= fl' 4. Number of Bedrooms 2 d. N/A R= ft' 10. Ceiling Types (787.0 sqft.) Insulation Area 5. Is this a worst case? _ No a. Under Attic (Vented) R=38.0 787.00 fl 6. Conditioned floor area above grade (ft2) 787 b. N/A R= ft' A - V c. N/A R= ft' Conditioned floor area below grad6 (ft') 0 11 Duds R ft' 7. Windows(50.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 225 a. U-Factor. Dbl, U=0.33 50.00 ft' SHGC: SHGC=0.27 ft' 12. Cooling systems kBtu/hr Efficiencyb. U-Factor. N/A a. Central Unit 18.0 SEER:15.00 SHGC: c. U-Factor: N/A ft' SHGC: - 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 17.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.270 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (787.0 sqft.) Insulation Area EF: 0.650 a. Slab -On -Grade Edge Insulation R=0.0 787.00 fN b. Conservation features b. N/A R= ft' None c. N/A R= fe 15. Credits None Glass/Floor Area: 0.064 Total Proposed Modified Loads: 25.97 PASS Total Baseline Loads: 28.87 1 hereby certify that the plans and specifications covered by Review of the plans and OE-VAE ST47 this calculation are in compliance with the Florida Energy specifications covered by this indicatesCode. calculation compliance with the Florida Energy Code. On."••• `:= t. O PREPARED BY: ._..__-__ _.._. _ DATE: Before construction is completed this building will be inspected for V I i .p-` a compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. COOwiththeFloridaEnergyCode. WE OWNER/AGENT: _ ._-____ . _._ .. ___. _ _-__.__ BUILDING OFFICIAL: __ . DATE: - -- - - - - --- - ----_---...._...- DATE: -- - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/17/2017 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 SCPA Parcel View: 25-19-30-5AG-1009-0060 Page 1 of 2 PATAL6 rxw+acooum; wna Parcel information Property Record Card Parcel: 25-19-30.5AG-1009-0060 Owner: COASTLINE APARTMENTS LLC Property Address: 610 W 9TH ST SANFORD. FL 32771 r Value Summary Parcel 25.19-3D-5AG-1009.0060 Owner COASTLINE APARTMENTS LLC Property Address 610 W 9TH ST SANFORD, FL 32771 Mailing 815 S FRENCH AVE SANFORD, FL 32771 Subdivision Name SANFORD TOWN OF Tax District S4-SANFORD- 17-92 REDVDST DOR Use Code 10-VAC GENERAL -COMMERCIAL Exemptions 6 7 j 2 1 2 9 c v 3 3/ mj 4 5 g 10 4 L-Seminolop-ouall GIS i Legal Description LOTS 6 + 7 BLK 10 TR 9 TOWN OF SANFORD PB 1 PG 62 LOTS 8 9 + 10 BLK 10 TR 9 A C MARTINS ADD rPB 1 PG 62 I Taxes Taxing Authority County General Fund Schools City Sanford SJWM(Saint Johns Water Management) County Bonds Sales 2017 Working 2016 Certified Values Values Valuation Method Cost/Markat i Cost/Market Number of Buildings 0 0 Depredated Bldg Value Depredated EXFT Value Land Value (Market) 61,666 61*566 Land Value Ag Just/Markel Value •' 61.566 61.566 Portability Adj— Save Our Homes Adj s0 — fis0 28.508 s31,513Amendment1Adj P&G Adj __ 1 s0 _ i r s0_ _ Assessed Value 33.058 30,053 Tax Amount without SOH: 5840.57 2016 Tax Bill Amount $840.57 Tax Estimator Save Our Homes Savings. $0.00 TRIM Notice HEID Does NOT INCLUDE Non Ad Valorem Assessments Assessment Value Exempt Values Taxable Value 533,058 s0 $33.058 0 $61.566 33.058 s0 $33.058 33,058 $0 $33,058 533,058 --- SO -- $33.058 Description Date Book Page Amount Qualified Vadlmp WARRANTY DEED WARRANTY DEED -- — — - 2/1/2017 1211/2004 -- 5/1/1998 08869 05557 — 03428 0422 0363 -- 1724 220.000 110,000 63.400 Yes I Vacant Yes -- — Improved Yes -Improved -- Yes Improved WARRANTY DEED WARRANTY DEED 2/1/1985 01617 04 7 71.300 QUIT CLAIM DEED 2/1/1985 01617 0476 100 No --- Improved - - - No I ImprovedQUITCLAIMDEED7/1/1980 01728 Q9 3 a100 Find Comparable Sales Land Method ` Frontage Depth Units Units Price land Value SQUARE FEET 0001 0.00 307631 $2.001 61,566 Building Information http://parceidetail.scpafl.org/ParcelDetailInfo.aspx?PID=2519305AG 10090060 9/25/2017 SCPA Parcel View: 25-19-30-5AG-1009-0060 Page 2 of 2 Permits Permit # Description Agency Amount CO Date Permit Date 01072 DEMO. 2 FAMILY HOMES. PAD PER PERMIT: 610 W 9TH ST I SANFORD 4.210 i 4f7/2016 02753 REPLACE ELECTRICAL DEMOLISH SFR REPLACE WINDOWS: 610 1/2 W 9TH ST SANFORD I SANFORD J SANFORD s1,5007/19/2007 1. 000 , 7/17/2003 200 ; 511/1999 02526 02215 Extra Features Description Year Built Units Value New Cost No Extra Features http:// parceldetail.scpafl.org/ParcelDetailInfo.aspx?PID=2519305AG 10090060 9/25/2017 Billing Department IREMODEL BUILDING CONTRACT P.O. Box 625 RLH r Sanford, F1,32,772-0625 MvGC(a)RLHMN1anaana2ememenGcom CONSTRUCTION COMPANY License N: CBC1251684/CGCI512297 Reliable Luxury Phone 407-330-7104 Habitations Fax 407-328-8055 Work Write Up/JOB SCOPE AND PRICING Date: March 29, 2017 Page 1 of 2 Client: Coastline Apartments Address: 815 S. French Ave Cti /State/Zi : Sanford, FL 32771 Job Number: NA Report No: N/A Property Address: 610 W. 91 St. Fax Phone: 407-328-8055 Work Phone: 407-322-0126 City: Sanford Cell Ph.: Email: Claim or Policy No. N/A 1 Insurance amount: N/A After review of the above referenced property, including specifications, supplied by the owner; our firm shall furnish all labor and materials for a lump sum of S 835.000.00 for stated work listed in the job scope below: CONSTRUCTION DESCRIPTION OF WORK TO BE COMPLETED ESTIMATED DIVISION CODES COST Division New Light Commercial Construction. 16 Apartment Building Complex TOTALS 1 835 000.00 All work will be in accordance with state and local codes and will be quality workmanship. We look forward to working with you on this project and should you have any questions, concerns, please do not hesitate to contact US. This price is good for fourteen days, after that it will be subject to repricing of current market. No price shall be honored after fourteen days. COASTLINE APRTMEN'rs CONTRACT Billing Department REMODEL BUILDING CONTRACTP.O. Box 625 RLHiws- Sanford, FL 32772-0625 MvCCt7RLHMana2ement.com Page 2 of 2 CONSTRUCTION COMPANY License #: CBC12516P/CGC1512297 Reliable Luxury Habitations Phone 407-330-7104Fax407-328-8055 RLH Construction Company proposes to furnish the material and labor necessary to complete the above referenced job. Please see the attached Job Scope and Pricing for details: (SEE PAGES 1-2) 1. PAYMENT TERMS: All labor and materials quoted in "Total Cost Of Job" above shall be invoiced to customer. Full amount of invoice shall be due and payable within 15 days of the invoice date. Invoices for which payment is not paid by due date shall be deemed to be Past Due and shall incur a service charge of $100 and interest will begin accruing from the invoice date at the rate of 18% per annum (1.5% per month), on the unpaid balance until paid in full. Furthermore, customer shall be deemed to be in Default Of Contract until full payment of invoice and service charge and interest has been paid on Past Due invoice. 2. DEFAULT OF CONTRACT: Failure to pay invoice in accordance with PAYMENT TERMS shall be deemed to put customer in Default Of Contract with respect to all of the terms of this Contract and with respect to the obligation of Customer under this Contract. RLH Construction Company shall have the right to immediately cease all work, demobilize from this job and all other jobs being performed for customer, with no liability to RLH Construction Company Customer shall be responsible for all costs and -expenses and collections costs and expenses, including a reasonable sum for profit and overhead, for such demobilization and any subsequent agreed upon remobilization, all of which must be paid in advance of remobilization. In the event an attorney is retained to enforce the terms of this Contract, Customer shall pay all legal fees, costs and expenses incurred for the employment of counsel, whether based upon suit being filed or not, and all such fees, costs and expenses at the trial level and upon appeal. In the event of suit, Customer stipulates and agrees to waive venue as provided under Chapter 47, Florida Statutes, and agrees venue for all litigation between the parties shall be in the appropriate court having jurisdiction located in Seminole County, Florida. 3. GUARANTY OF CONTRACT: Notwithstanding any term, title, or qualification set forth by the signature of the Customer or Customer's employee or agent signing this Contract, said individual shall be personally bound by and liable for the obligations of Customer to RLH Construction Company, as set forth in this Contract. 4. CHANGES TO CONTRACT: This Contract may not be changed or modified except by a written agreement signed by both parties hereto. Thank you for the opportunity to quote this project. By signing below you are agreeing to pay the Total Cost of Job according to the terms of this contract for the Work desired as identified in the Job Scope. CONTRACTOR: Prepared and Presented by: OWNER/Agent(S):Reviewed and Accepted by: R . ! anf Joseph Hillery, Vice President Date: SIN117 RT. Hillery Date: A10117 COASTLINE APRTMENTS CONTRACT ECERVE MAR 3 0 2017 CITY OF SANFORD BUILDING & FIRE PREVENTIONSTPERMITAPPLICATION Application No: Documented Construction Value: S. 835,000 Job Address: 610 W. 9th Steet Historic District: Yes No Parcel ID: 25-19-30-512-1009-0060 & 25-19-30-512-1009-0080 Residential Commercial El Type of Work: New Addition Alteration Repair Demo Change of Use Move • Description of Work: New 16 Unit Apartment Complex Plan Review Contact Person: Phone: 407-688-7644 Fax: 407-688-7920 . Email: bob()_suncorproperties.com Property Owner Information Name Coastline Park LLC Phone: 407-322-0126 Street: 815 S. French Ave Resident of property? : City, State Zip: Sanford, FL 32771 Contractor Information Name RLH Co str c Phone: 407-330-7104 Street: PO Box 0625 Fax: 407-328-8055 City, State Zip: Sanford, FL 32772 State License No.: CGC 1512297 Arch itect/E ng 1 neer Information Name: WDS Design Group Street: 2612 Herbison Dr. City, St, Zip: Orlando, FL 32810 Bonding Company: Address: Phone: 407-298-4679 E-mail: wshaffer8a( o, cfl.rr.com Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5"Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in at,cordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, ctfedit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. r&45 3/27/17 Signature of Owner/A Date ' RT Hillery Print caner/Agent's Name Signature oflNN#yL19RtF6fS Date o,. 901.t,^ Notary Public State of Florida My Commission Expires 11/27/2020 0wner/6@ S10q &y6@aWb&pwn to Me of Produced ID yC Type of ID .L Or I . 0 ZU 3/27/17 Signature orContractor/Agent Date J.M. Hillery Sr. Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Flood Zone: Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures, Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: 1A VC G't;°1FIRE: COMMENTS: Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application Revision Response to Comments,,,--- omments' U" JUL 3 1 h4b--,- Permit # Submittal Date Project Address: /y / ld Contact: Ph: Email: Trades encompassed in revision: Building Plumbing Electrical Mechanical Waste Water Department Utilities Waste Water Planning Engineering Fax: City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov General description of revision: ROUTING INFORMATION Fire Prevention building 7. -2 Approvals N1110 MiTek' RE: 738245 - 738245 Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values *esstaklieft, y others. PERMIT MpR30 Site Information: Customer Info: Suncor Properties Lot/ Block: Address: 610 W. 9th Street City: Sanford Y• SA, Inc. 6904 Parke East Blvd. Project Name: Model: 16 Unit Townhome Tampa, FL 33610-4115 Subdivision: State: Florida Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 Wind Speed: 140 mph Roof Load: 37.0 psf Floor Load: N/A psf OFFICE This package includes 21 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. I Seal# Truss Name Date No. I Seal# russ Name Date 1 IT10660405JAl 3/16/17 118 1 T1 06604221 PB1 3/16/17 12 I T10660406 I A2 13/16/17 119 I T1 0660423 I P62 1 3/16/17 I 13 IT10660407IA3 13/16/17 120 1 T10660424 I V1 1 3/16/17 1 4 T10660408 1 A4 3/16/17 121 IT10660425IV2 3/16/17 5 T10660409 A5 3/16/17 I I 1 1 6 T10660410 A6 3/16/17 7 T10660411 A7 3/16/17 18 I T10660412 I 131 1 3/16/17 19 I T106604131 B2 13/16/17 10 T10660414 1 B3 3/16/17 11 T10660415 CJ1 3/16/17 12 T10660416 1 CM 3/16/17 113 I T10660417 1 CJ5 13/16/17 114 T106604181 ER 1 3/16/17 15 T10660419 EJ9 3/16/17 16 T10660420 HJ7 3/16/17 117 1 T10660421 1 MG1 1 3/16/17 The truss drawing( s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by American Builders Supply, Inc.. Truss Design Engineer' s Name: Velez, Joaquin My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSIlTPI 1, Chapter 2. 11 111/11' Q N 68182 • op ccZ O :•• TAT E OF : 0 S/.p N A1- E 111111111 Joaq nVel PE No.68182 Mir USA,1 . Ft. Cert %M. 6904 arks 6W. Tampa Fl. 33610 Date: March 16, 2017 Velez, Joaquin 1 of 1 Job Truss Truss Type oty ply 7-38245T 106738245AtHellHipGirder4tobReferenceotronal I Th Ma 16 0-435 2017 P 1 American Builders Supply, writer Haven. Florida 33880 7.640 s Apr 19 2016 PATek IfMuslfras. nc. u r e9e ID:r11OCSOkwZVhwYIOSTM4_yznGrl-ZkN2OyBxO4eO43c1 fUWGcrrgCoZ31 Y4YIveSzaScO t•4-0 7.0.12 0-0-0 16.1.15 23.2.1 30.4-0 1-4-0 7.0.12 1.11.4 7.1.15 7-0.3 7-1-15 7x10 MT20HS - r Scale = 1:68.3 30 = 20 II 700 = 8x14 = 19 20 5 21 22 23 6 724 25 26 a to 27 - 14 13 rr — - 5x10 MT20HS i 2x4 11 6x6 = 7x10 MT20HS WB = 7x10 = Sx10 MT20HS 11 7x10 = 7: ih0-0 16.1.15 23.2.1 304-0 7.0 12 1.11.4 7.1.15 7-0.3 7.1-15 Plate Offsets (X Y)-- 12:0.4-3 0.3.01,14:0.6-12,0-2-121,17:0.4.0,0-4-81,19:Egge 0-3.81 I10:0-3-8 0.4-4) 111:0.3.0 0-4-121 113:0.2-0,0.4-81,115:0-2-0.0-0.01 LOADING (psi) SPACING- 2-0-0 CSI. DEFL, in poc) Wait Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) -0.53 11.13 >687 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(TL) -0.92 11.13 >394 180 MT20HS 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.96 Horz(TL) 0.10 18 n/a We BCDL 10.0 Code FBC2014/fP12007 (Matrix-M) Weight: 204 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x6 SP N0.2 'Except' TOP CHORD Structural wood sheathing directly applied or 2-1-12 oc puffins, except 1-4: 2x4 SP M 30 end verticals. BOT CHORD 2x6 SP 240OF 2.0E BOT CHORD Rigid ceiling directly applied or 6-7-1 oc bracing. WEBS 20 SP No.3'Except* WEBS 1 Row at midpt 8-10 8.9,6-11: 20 SP No.2, 4.11,8-10: 20 SP M 30 OTHERS 20 SP No.3 REACTIONS. (Ib/size) 2=2757/0-8.0, 18=3078/0-2-8 Max Harz 2=188(LC 40) Max Uplift2-1092(LC 4), 18=-1384(LC 4) Max Grav 2=3001 (LC 29), 18=3699(LC 35) FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-7328/2619, 3-4=•7175/2595, 4-19=-8271/3038, 19.20=-8272/3038, 5-20-8272/3038, 5.21=-8271/3036, 21.22=-8271/3036, 22-23=-8271/3036, 6-23=-8271/3036, 6.7-5898/2202, 7-24=-5898/2202, 24-25— 5898/2202, 25-26— 589W202, 8-26=-589W202,9-15=-154/1007,8-15-154/1007 BOT CHORD 2-27-2462/6742, 2.28=-2471/6754, 14.28=-2471/6754, 14-29=-2471/6754, 13-29-2471/6754, 13-30=-2385/6555, 30-31=-2385/6555, 31.32=-2385/6555, 12-32=-2385/6555, 12.33-2385/6555, 11-33=-2385/6555, 11-34=-2202/5898, 34.35-2202/5898, 35-36=-2202/5898, 10-36-2202/5898, 10-37=-176/461, 37-38=-176/461, 38-39=-176/461, 39.40=-176/461, 9-40=-176/461 WEBS 3-14=-64/464,3-13=-577/253,4.13=-567/1924,4-11=-744/2090, 5.11-503/382, 6-11-942/2802, 6.10=-1433/803, 8-10=-2277/6134 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; VU11=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6 Opsf; h=151t; Cat. II; Exp B; Encl., GCpl=0.18; MW FRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 6) 'This truss has been designed for a live load of 20.Ops1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 18 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 18. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1092 lb uplift at joint 2 and 1384 lb uplift at joint 18. 10) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the WARNING • Vadly deOgn parametars and READ NOTES ON THIS AND WCLUOEO MREK REFERANCE PAGE MIF7473 mv. IMIW15 BEFORE USE. Deslgl valkl fa use only with MIleliS Conr eCtors. IM deSIgn it based afdy urxxl parameters shown. and Is for an trxrlvkkxD 1AAcling cofnponenl, not a buss syslem. Before tae. the I"ding deslpnef rust verity the af)0lcc llty of design txnameters arxl txopefly hcofporalo tuts dt-4n Into the overall buildhtp design. Bracing hx9coled Is to ixevent Ixfckling of IndlMucil truss web aril/or chord mofnbers only Addlllonal terllpotary and permanent bracing Welk' Is always regal ed for stability and to Ixevenl collapse with 1wssOtle personal hpay aril properly damage. For general guidance regadng Me fabrk:01601% storage, delivery. Crocaon and brachlg of trusses aril truss systems, seeANSLI Pl l Quality Criteria, DS6-89 and SCSI 8ullding Component 6904 Parke East Blvd Safety Information OvallalAe horn buss Plate h slllute. 218 N. lee Street. Sulte 312, Alexa cJda. VA 22314. Tampa, FL 33610 Job rues ruse Type N 738245 Tt0660405 73824S Al Hall Hip Girder 1 Job Reference ironal AMOIICOn UUlgerB bUPPry• yr hied nWv..rgrgo J,woV ...-..•.r• •-•-.•-. _.•..._--...--•..._. ..._.. . _ __._ ____ ID:r??OCSOkwZVhwYlOSTM4_yznGrl-ZkN2OyBxO4eO43e1 fUWGcrrgcoZ31 Y4YIveSzaSCO NOTES- 11)'Semi-rigid pltchbreaks with lixed heels' Member end fixity model was used In the analysis and design of this truss. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 37 lb down and 60 lb up at 9.0-0, 22 lb down and 60 lb up at 11.0.12, 33 lb down and 89 lb up at 14-11-4, 22 lb down and 60 lb up at 17-5-4, 22 lb down and 60 lb up at 19-5-4, 24 lb down and 64 lb up at 21-5-4, 24 lb down and 64 lb up at 23.8-12, 22 lb down and 60 lb up a1 25.8-12, and 22 lb down and 60 lb up at 27-8-12, and 38 lb down and 65lb up at 29-10-12 on top chord, and 622 lb down and 238 lb up at 7-0-12, 336 Ib down and 1O01b up at 9-0-12, 336 lb down and 1001b up at 11-0-12, 597 lb down and 213 lb up at 12-11-4, 2671b down and 28 ib up al 14-11-4, 597 lb down and 213 Ib up at 16-0.12, 3361b down and 100 Ib up at 17-5-4, 336 Ib down and 100 Ib up at 19-5-4, 342 Ib down and 107 Ib up at 21-5.4, 342 lb down and 107 lb up at 23.8.12, 336 lb down and 100 lb up at 25.8-12, and 336 lb down and 100 lb up at 27-8-12. and 344 lb down and 91 lb up at 29-10-12 on bottom chord. The designtselection of such connection device(s) is the responsibility of others. 13) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Unllorm Loads (pit) Vert: 1.4=-54, 4-8=-54, 2-9=-20 Concentrated Loads (Ib) Vert: 4=-18(F) 8=-38(F) 9=-215(F) 14=-595(F) 13=-207(F) 11=-412(F) 19=-18(F) 20=-32(F) 21_ 18(F) 22=-18(F) 23=-20(F) 24=-20(F) 25=-18(F) 26=-18(F) 30=-207(F) 32=-412(F) 33=-18(F) 34-207(F)35=-207(F)36=-220(F) 37=-220(F)38= 207(F)40=-207(F) Q WARNING • Val7y dWgn perwWm end READ NOTES ON TW ANDWCLUDEO NrrEK REFERANCE PAGE N47473 rev. I&MWIS BEFORE USE. Design valid to use orgy with WIek® connectors. 11* design Is based only upon pusametem shown, and Is to an Individual building component, not a truss system Betoto use. the building doslgnet must verily the applkab illy of design paraneters and property Incorporato this design Into the overall pOding design. &acing Irnticalod Is to prevent buckling of hntividttai Inns web and/a chord members only. Adcllllonal temporary and permanent pacing WOW Is always regtrred for stability and to povenl collapse with pow1ble personal Injury and popedy darnage. for general guidance regarding the lapktallon. stdrago, dlollvery, erection and pacing of trusses and truss s IG"s. seeANSI/TPI I Quality Cdtwla, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avCW>le from htas Rate Institute, 218 N. Lee Sheet. Sidle 312, Alexandria. VA 22314. Tampa. FL 33610 Job Truss Type Uty Ply 739245 T106604p6 739245 A2 JTrussHallHip 4 1 Job Reference lional ewn- w. .n Tk„ U.. C nf. 7•u 9M7 P.n. 1 Amerwan aurldere 5uppq. winter noven, rrorrao aaeev .,....-- ID:r??OCSOkwZVhwYIOSTM4_yznGrl-1 xxObICZBNmFrCBVYNPIppliPb9moKniIC2TAuzascP 1.4-0 6.6-5 11-0-0 17.4.3 23.9.5 30.4.0 1-0 "-5 4.5.11 64-3 6.4-3 67.11 Scale . 1:56.4 30 = 4x4 = 30 5x6 = 6x6 II 4x4 = 2x4 11 US = 06 = 3x4 = firs = LOADING (psi) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2014lrP12007 CSI. TC 0.68 BC 0.82 W B 0.48 Matrix-S) DEFL. in Veri(LL) -0.43 Vert(TL) -0.69 Horz(rL) 0.07 loc) Wall Ud 8-9 >839 240 9-11 >526 180 17 We Na PLATES GRIP MT20 244/190 Weight: 162 lb FT is 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD 20 SP M 30 BOT CHORD Rigid telling directly applied. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpi 6.8 7-8: 20 SP No.2 OTHERS 20 SP No.3 REACTIONS. (Ib/size) 2=1204/0-8-0, 17=1080/0-1-8 Max Horz2=227(LC 12) Max Uplitt2-300(LC 8), 17=-344(LC 8) FORCES. ( lb) - Max. CompJMax. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-18=-2244/651, 18.19=-2178/659, 3-19=-2161/668, 3-4-1868/563, 4-5=-1693/557, 5. 20=-1589/456, 6-20=-1589/456, 8-13-242/925, 7.13=-242/925 BOT CHORD 2-21=-695/1690, 2-22=-758/2010, 12-22=-758/2010, 12-23=-758/2010, 11-23-758/2010, 10- 1 1=-578/1787,10.24=-578/1787, 9-24=-578/1787, 9.25=-422/1254, 8-25=-422/1254 WEBS 3.12— 8/317, 3.11-434/236, 4-11— 41/444, 5-9=-350/241, 6.9-87/595, 6.8=-1400/484 NOTES 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=151t; Cat. II; Exp B; Encl., GCpi=018; MW FRS (envelope) gable end zone and C-C Extedor(2) -1-4.0 to 4-8-0, Interior(1) 4-8-0 to 11-0.0, Exterior(2) 11-0-0 to 19-5-13 zone; C-C for members and forces t3 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3.6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 17 considers parallel to grain value using ANSIIrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 17. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 300 lb uplift at joint 2 and 344 lb uplift at joint 17. 8) This buss has been designed for a moving concentrated load of 250.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) This truss design requires that a minimum of 7/167 structural wood sheathing be applied directly to the top chord and K" gypsum sheelrock be applied directly to the bottom chord. WARMING- VorW deeryn peremerere and READ NOTES ON MS AND WCLUDED Uf EK REFERANCE PAGE M4473 rov. 16=14015 BEFORE USE. Design valld lot use only with Mlletd® connectors. this design Is based orgy upon Ixlramelers shown. and Is fa an Individual bulding component, not o Russ system. Before use, the lxlkilng designer mull verify the cw1cobllN of design parameters and Ixopedy Incorporate 0% design Into the ovetcdl Additional temporary and permdxent bracing MiTek' btNcMVdesign. Blactng tnalcated Is to rxevenl buckling of In1d11vkAlcd it=web and/or chord members orgy. 6 dwoys redadrod lot stability and to fxevenl collgne vAth possible personal aVt+y cod property damage. For general guidance regadng the lalxk: atkm. sfofoge. ddivary. erection and bracing of trusses aril Inns systems. soeANS1/TPI I Dually Criteria, D$9.99 and SCSI Wilding Component 6904 Parke East Blvd Safety Informalon ovallable from buss Rate Institute. 218 N. Lee Street, State 312. Alexandria. VA 22314. Tampa, FL 33610 Jo runs Truss Type ry 738245 Tt0660407 738245 1'3 Hall Hip 4 1 Job Reference lional 7 PAmericanBuildersSupply, IN or Haven, Fbrdo 33880 7 640 s Apr 18 2016 MrTek Indusuies. Ina Thu Mar 16 06 24:T, 201 age 1 ID:r??OCSOkwZVhwY108TM4_yznGrl-W 7VppeCByhu6JMmhS4w_L1 gtxJ? W kXhvrXsnOjLzaSeO 1.4.0 63.5 13.0-0 18.8.3 24.4.5 30.4.0 r 1.4 0 6.3.5 6•8.11 5 6 3 5 8-3 5 11.11 nz 4x4 = 20 It 4x6 = 30 = US = Sx6 = 1e 30 = 3x4 = 6 30 = 3x4 = 6x6 II 6x6 = Style = 1:56.4 17 d LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in loc) Wall L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) -0.32 9-11 >999 240 MT20 244/19D TCDL 7.0 Lumber DOL 1.25 BC 0.71 Vert(R) -0.51 9.11 >714 ISO BCLL 0.0 ' Rep Stress Incr YES WB 0.61 Horz(TL) 0.07 17 We n/a BCDL 10.0 Code FBC2014/rP12007 Matrix-S) Weight: 170lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD 20 SP M 30 BOT CHORD Rigid ceiling directly applied. WEBS 20 SP No.3 *Except* WEBS 1 Row at midpi 6-8 7-8: 2x4 SP No.2 OTHERS 20 SP No.3 REACTIONS. (lb/size) 2=120210-8.0, 17=108210.1.8 Max Horz2=265(LC 12) Max Uplift2=-296(LC 12), 17>339(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-18=-2310/664, 3-18=-2204/674, 3-4_ 1725/512, 4-5=-1533/529, 5.19— 1267/365, 6.19— 1267/365, 8.13= 250/945, 7.13=-250/945 BOT CHORD 2-20=-551/1518, 2-21= 80at2079, 12-21=-80a/2079, 12.22=-B08/2079, 11-22=-80WO79, 10-11=-476/1462, 10.23— 476/1462, 23.24=476/1462, 9-24=-476/1462, 9-25=-323/982, 25-26= 323/982, 8.26= 3231982 WEBS 3-12=0/355, 3-11=-594/299, 4.11=0/379, 5-9_ 422/240, 6.9— 114/639, 6.8— 1234/415 NOTES- 1) Wind: ASCE 7-10; VUlt=140mph (3-second gust) Vasd=108mph; TCDL=4,2ps1; BCDL=6.Opsf; h=151t; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Exlerior(2) -1-4-0 to 4-8-0, Interior(1) 4-8-0 to 13.0-0, Exterior(2)13-0-0 to 21-5-13 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psl bottom chord live load nonconcurreni with any other live loads. 4) ' This truss has been designed for a live load of 20.Opst on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0.0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsl. 5) Bearing at joint(s) 17 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 17. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 296 lb uplift at joint 2 and 339 lb uplift at joint 17. 8) This truss has been designed for a moving concentrated load of 250.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 14" gypsum sheetrock be applied directly to the bottom chord. WARNING. V4rIy design parameters and READ NOTES ON THIS AND INCLUDED 4i!!EK REFERANCE PAGE MI.7473 rev. IOMW IS BEFORE USE Design valkl for use only with Mllek®connectois. this design E based) only ul»n paametem shown. and Is far an hdlvkkml Ixdding component, not a htat system. Belau tee. the 1>tdalng deslgnrn mull verity lho opplk:at-Ally of design pdaamolers and properly Wor1>oralo this dosign Into the overall IxdW1g design. aachg Indicated Is to prevent bucldpng of IndWtrd tngs wet> and/or chord members only. Additional lempotar , and permanent bracing WOW Is always rogt0ed for slal>Illly and to prevent collapse wllh possible personal k*ffy and property damage. For (general guidance regarding the fabrication, storage. delivery. oreclbn and bracing of inNses and ins) syslems st.-eANSI/IPI I Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information ovdlable groin liters Rate Instltute. 218 N. Lee Slioel. Sudte 312. Aloxardria. VA 22314. Tampa, FL 33610 Job russ rush Type oty Ply 73824s T10660408 738245 A4 ROOF TRUSS 4 tI Job Reference (Optional) c.n TA„ us, tC na Dc•7a'lnt7 P.n. t American ounceiaaupPy-.,a,.oven, r-M. ,a.wtry -' - I D:r??OCSOkwNhwY108TM4_yznGrl•SVdZEKERT18pZgw4DVySOSwBgpBb?bT8?AG7nDzaScM 19.2.5 r14•q 6 1.13 t1.OA /7A0 t7.2.5 21.2.5 p 232.5 i 2S2.5 , 27.2.5 24.2.5 t•-0 bt•13 4.10.3 600 0.2.5 2.0.0 2.0.0 2•e-0 2•aV 2.4e t-t•tt 2•0-0 30 Sole = 1:81.8 THIS COMPONENT IS TO BE USED IN 30 = CONJUNCTION WITH A RIGID DIAPHRAGM. 3x4 = THIS DIAPHRAGM MUST BE CAPABLE OF TRANSFERRING ROOF LOADS TO THE GROUND 3x4 = WITH NEGLIGIBLE LATERAL DEFLECTIONS. SX6 7- 6x6 II 9 M.11,11--ill 4V 11-0ar ac 6ayp ..12 ,. 10 ,. e 7x8 = 4x6 = Sx6 = 5x6 = 40 = LOADING ( psi) SPACING- 2-0-0 CSI. DEFL. in poc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.26 12-13 >999 240 MT20 244/19D TCDL 7.0 Lumber DOL 1.25 BC 0.81 Vert(fL) 0.54 12-13 >672 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.87 Horz(TL) 0.10 36 rVa n1a BCDL 10.0 Code FBC2014/rP12007 Matrix-S) Attic 0,17 12.13 464 360 Weight: 256lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No 2 TOP CHORD Structural wood sheathing directly applied, except end verticals, and BOT CHORD 20 SP M 30 4.0.0 oc puffins (6-0-0 max.): 7-8. WEBS 2x4 SP No.3 Except* BOT CHORD Rigid ceiling directly applied. 6. 17: 20 SP No.2 WEBS 1 Row at midpt 5.31, 9-16, 10-31 OTHERS 20 SP No.3 JOINTS 1 Brace at JI(s). 8, 15, 16, 31 REACTIONS. ( Ib/size) 2=1357/0-8-0, 36=1291/0.1-8 Max Horz 2=455(LC 12) Max Uplif12-204(LC 12), 36=-158(LC 12) Max Grav2=1417(LC 2), 36=1384(LC 2) FORCES. ( Ib) - Max. CompJMax. Ten. - All forces 250 pb) or less except when shown. TOP CHORD 2-37=-2879/222, 3-37=-2811/231, 3-4=-2635/95, 4-5-2590/109, 5-38=-1040/117, 6- 38=-977/118,9-32-167/1212, 17-32=-168/1212,8.17=-162/1236 BOT CHORD 2.39=-696/1893, 2AO=-573/2609, 14.40=-573/2609, 14-41=.573/2609, 13-41— 5732609, 13. 42— 344/2371. 42-43— 344/2371, 43-44-3442371, 12.44-344/2371, 11- 12-3462357, 11.45-346 2357, 10-45=-3462357, 10-46=-259/1284, 46-47-259/1284, 9.47=-259/1284 WEBS 3-14-31/ 3D2, 3-13=-427236, 13-18=0/579, 5-18=0/614, 5.31=-1400290, 12-31=0/468, 7-16=-392/376, 9-16=-1649287, 10-16=0/853, 6-15=-879/369, 15-16-8e8/362, 10-31-1291/127, 16.31=-36823 NOTES- 1) Wind: ASCE 7- 10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2pst; BCDL=6.Opsl; h=1511; Cat. 11; Exp B; Encl., GCpl=0.18; MWFRS (envelope) gable end zone and C-C Extedor(2)-1-4-0 to 4-8-0,Interior(1) 4-8-0 to 23-2-5, Exterlor(2) 23.2-5 to 29-10-12 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) 150.01b AC unit load placed on the bottom chord, 14-0-0 from left end, supported at two points, 5-0-0 apart. 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord In all areas where a rectangle 3.6-0 tall by 2-0-0 wide will lit between the bottom chord and any other members, with BCDL = 1 O.Opsl. 7) Ceiling dead load ( 5.0 psi) on member(s). 6-15, 15-16, 16.17, 18-31 8) Bottom chord live load (40.0 psi) and additional bottom chord dead load (0.0 psl) applied only to room. 12-13 9) Bearing at joint( s) 36 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection ( by others) of truss to bearing plate at joint(s) 36. 11) Provide mechanical connection ( by others) of truss to bearing plate capable of withstanding 204 lb uplift at joint 2 and 158 lb uplift at joint 36. 12) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the 0 WARNING - Vadly dodpn pwamoters and READ NOTES ON TNLS AND INCLUDED M TEK REFERANCE PAGE N67473 rev. 1""016 BEFORE USE. Design vol d rot use only with M1106 conneclors 1Ns design Is based only t4»n parameters sLwwn. and Is to an frxiivkkral txrlding component. not ust vedly the appllCOb1lIY of desixaelors and properly incorporate 11* design Into the Overall a cuss system. Belowtae, the Wilding designer must design prm AWHOnal temporary and permanent brachV MiTek' LxUd rvj design. BrachgIndicatedIstopreventbreklirlgofIndividualtrussweband/or chard members onlY• is always to it/ red for stability and to prevent collapse with possible personal Irtluy and property damage. for general gtddarlce regarding tine faUrlcallon, storage. delNery. erection and brachg of Irussos and truss systems. seoANSI/TVI I Ouatily Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Solely Information avallabie from huss Plate Instlluto, 218 N. Lee Sheol. Surge 312. Alexandria. VA 22314. Ter pa. FL 33610 Job I russ Type ty 73824s T1066040B 738245 A4 ITrUSSROOF TRUSS 41 Job Reference o trfmal e,•_ ........ 1•w.. u.,. to ne 7e9D Jnt1 Dnn D Arnerlten Builders Supply. wlnl/l Maven. mown jitraw .— o.- 1.1 o........._.-.. ..._.. ___ ID:r??OCSOkwZVhwYlOSTM4_yznGrl-SVdZEKERT18pZgw4DVySOSw8gpBb?bT8?AG7nDzaScM NOTES- 13) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and W gypsum sheetrock be applied directly to the bottom chord. 14) Graphical purtin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. 15) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. Q WARNING - Vanity design pamaralers and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIF7473 rov. 100MIS BEFORE USE. Design valid for use only vAlh Mllek®conneCtors. Inls design S based only upon prsarneters shfown, and Is for an frxJlvkhfal txBtlbg component, not o inns syslem. Before rise, the Ixilalng designer must verily the applicablity of design rxxametefs and property Incorporate M dospgn lnlo the over,,, Ac"llond krnpora and permanent bracing MlxOdngdoslgn. ®acing Irxdkoled Is to pxevenl Ixrclding of indivklual buss web and/or chord members only. y Is always reWied for stolAlty and to prevent collapse wllh p ossltilo persona, Whey and property damage. For general gt,daltoe rogaalng the latxlaallon, storago. delivery, erection and Ixacing of misses arKI Inns systems seeANSI/IPI I QwUly Cdterla, DSB-89 and 6CS1 Building Component ITBK• 6904 Pake East Blvd. Safety trxormaBon avalable from Irtns Rate Institute. 218 N. Lee Street, Sulle 312. Alexandra. VA 22314. Tampa. FL 33610 Job Truss Truss Type oty Ply 738245 Tt0660409 738245 AS ROOF TRUSS 112 1 Job Refererce o tional n pint) Dwn. t American Guilders supply. winter Haven. rrortao sseev I--. —1 ....... .._.,,.. ....__......._. ..._ ..—.._ -_._ ..._ -- .. _o_ - I D:r??OC SOkwZVtwYIOSTM4_yznGr I-wiBxRg F4 EcGgAgVGnDThzISMH DV9k2J HDgOgJgzaScL rtd-0 6.1.13 tt-0-0 _ 17-" 23.2.5 30.4,0 _ t-a-0 6.1.13 4-t0-3 6.0-0 6.2.5 7.1-N il 3x4 = Scale = 1:77 6 3x4 = 3x4 = 4x8 7x6 II 40 = 20 II 7x8 = 20 II 40 = 3x8 = 4x6 = 4 VP d LOADING (psi) SPACING- 2-0.0 CSI. DEFL. In (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.75 Vert(LL) 0.27 12-13 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(TL) 0.53 12-13 >686 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.89 Horc(TL) 0.08 21 n/a n1a BCDL 10.0 Code FBC2014/TPI2007 Matrix-M) Attic 0.17 12-13 459 360 Weight: 221 lb FT = 200% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3.3-10 oc puffins, except BOT CHORD 20 SP M 30 end verticals, and 4-0-0 oc puffins (6-0-0 max.): 7-8. WEBS 20 SP No.3 BOT CHORD Rigid ceiling directly applied or 9-2-7 oc bracing. OTHERS 20 SP No.3 WEBS 1 Row at midpi 5-15, 7-9, 10-15, 7-15 JOINTS 1 Brace at JI(s): 8,15 REACTIONS. (lb/size) 2=1319/0-8-0, 21=1179/0.1.8 Max Horz2=455(LC 12) Max Upl1112-227(LC 12), 21-225(LC 12) Max Grav 2= 1384 (LC 2), 21=1308(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-22=-2788/276, 3-22=-2720/285, 3-4=-2556/176, 4-5=-2511/189, 5-23=-82825, 6.23-732/35, 6.7-837/170, 9.17=-197/1161, 8.17=-197/1161 BOT CHORD 2-24= 688/1906, 2-25=-6232523, 14.25=-623/2523, 14-26=-623/2523, 13.26=-623/2523, 13.27= 4462300, 27-28=-446 2300, 28-29=-4462300, 12.29=-4462300, 11.12— 4482288, 11-30— 448/2288, 10.3D=-44e/2288, 10-31— 175/800, 31.32=-175/800, 9-32=-1751800 WEBS 3.14-14/310, 3.13= 423/207, 13.16--W554, 5-16=0/585, 5-15=-1604/323, 12-15--0/488, 6.15=-360/313, 7-10=-111/1154, 7-9-1290279, 10-15=-1789/352 NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.0psf; h=1511; Cat. 11; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Exlerior(2) -1-4-0 to 4.8.0, Interior(1) 4-8-0 to 23.2-5, Exterior(2) 23-2-5 to 29-10-12 zone-,C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) 150.01b AC unit load placed on the bottom chord, 14-0-0 from left end, supported at two points, 5.0-0 apart. 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load o1 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = IO.Opsf. 6) Ceiling dead load (5.0 psi) on member(s). 15.16 7) Bottom chord live load (40.0 psi) and additional bottom chord dead load (0.0 psi) applied only to room. t 2.13 8) Bearing at joint(s) 21 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 21. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 227 lb uplift at joint 2 and 225 lb uplift at joint 21. 11) This truss has been designed for a moving concentrated load of 250.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 12) 'Semi -rigid pitchbreaks including heels' Member end fixity model was used in the analysis and design of this truss. 13) Graphical puffin representation does not depict me size or bne onenianon of ine punm along the top anwvr uutivnr t.nvru. Q WARNWO - ysrtry ditagn parameters and READ NOTES ON THIS AND WCLUDEO M17EK REFERANCE PAGE M174473 rov. 100MIS BEFORE USE. Deslgn valld la use only vAlh MileW connectors. INS design Is based only upon pmanefers shown. and Is lot an individual rxulding component. not a Suss system. 9elote use. the txdlding dkAlgrlcp mtsl verily the oWlcabllly of design Ixsanelers and ptopenty hconponalo this design Into the overall Additional temporary and ponnanent btactng WOW building design. BrachgIndicatedIstopreventbuddingofindividualtrusswebanal/or chord members only. Is always io% dned Ion stablllty and to prevent collaixe vAlh powlllu personal hMy and propedy damage. Fa general gtfdlatce regarding the Iddrlcallm storage. delivery. erection and boocing of musses and truss systems. seeANSVIPII Quality Cdlerlo. DSB-89 and SCSI Building Component 6904 Ponke East Blvd Safety Information available bom buss Rae InsllNle. 218 N. tee Street. Sulle 312. Alexan drkr. VA 22314. Tongo, FL 33610 Job russ Truss Two Qty Ply 710660409 738245 AS ROOF TRUSS 112 1 1138241JobReference(optional) nn.c. vT_,.,_-_..._.... Tom...... .e ne.- nfin» 0.n.I American ousoers auppry. vnmm Haven. rrorge 0o uv- I D:r??OCSOkwZVhwYIOSTM4_yznGF I •wiBxRgF4 EcGgAq VGnDThzf SMH DVgk2J HDgOgJgzaSeL Q WARNING • Vail y desgn parnmetera and READ NOTES ON THIS AND INCLUDED AMEK REFERANCE PAGE MD7473 rev. 100"016 BEFORE USE. Design vaild lot use orgy vAth MllekO Conneclors. ais design Is based only upon rynarnelers slwwn, and Is for an 4xllvldial building component, not a frtra system. Before use• the txdld8ng designer must verify the applicability of design parameters and properly Incorporate M design Into the overall binding design. Bracing Indicated Is to prevent budding of Individual tnrss web and/or chord members only Additional tempadny and permanent bfuc-I lg MOW Is always required la slat -Ally and to prevent collapse wllh possiblo personal trtfury and property damage For general gu ldolce regarding the fabrIcallm storage. delivery. eFecllon and bracing of trusses and Inns systems. seeANSI/IPI I Quality Cdterlo, DS11-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information avdilable from buss Plate Institute. 218 N. lee Street. Sulle 312. Alexandria VA 22314. Tampa. FL 33610 Job cuss Truss Type Uty ply 738245 710660410 738245 A6 PIGGYBACK BASE 60 1 7 Job Reierenee Lanai ht! r..w..-,.:.. me n,,, Mew a nc24'41 2017 Penn t American Budder, Supply. winter Haven. Frorraa 33aav ....o_...._-......._ ..._.._. .-_—_ --- --o- ID:r??OCSOkwZVhwYlOSTM4_yznGrl•OukJe?Gi?wOXo_4SKw_WW I?XgdrXTUJRSUID66zascK 1.4 8-4.7 15-e-2 23.2.6 30.4.0 1.4.0 8-4.7 7.3.11 7.6.3 7.1-11 30 = Scale = 1:75.6 30 = 30 = Sx6 = 74 II 30 18 S 4x4 5.00 12 2x4 \\ 34 17 2 21 25 26 _ 30 = 4x6 = 30 = 3x8 = 6x6 = LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.71 Vert(LL) -0.51 8-9 >713 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Verl(TL) -0.81 8-9 >446 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.91 Horz(TL) 0.04 16 n/a We BCDL 10.0 Code FBC2014/TPI2007 Matrix-S) Weight: 184 lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied, except end verticals, and BOT CHORD 20 SP M 30 4-0-0 oc pudins (6.0.0 max.): 6.7. WEBS 20 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied. 7-8.20 SP No.2 WEBS 1 Row at midpt 6-8 OTHERS 20 SP No.3 REACTIONS. (lb/size) 2=120810.8-0, 16=1076/0-1.8 Max Horz2=455(LC 12) Max Uplitt2=-329(LC 12), 16=-312(LC 12) Max Grav2=1208(LC 1), 16=1126(LC 2) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 pb) or less except when shown. TOP CHORD 2-17=-2123/509, 3-17-2039/522, 3-4=-1884/457, 4-18= 1874/459, 5-18=-1760/481, 5- 6=-1074/264, 8-12=-294/985, 7-12=-294/985 BOT CHORD 2.19=-855/2292, 2-20=-820/1888, 11-20=-820(1888, 11-21=-538/1296, 10-21=-538/1296, 10- 22— 538/1296, 22-23— 538/1296, 9-23-538/1296, 9-24-253/650, 24-25— 2531650, 25. 26=-253/650, 8-26=-253/650 WEBS 3-11=-384/309, 5-11=-176/656, 5-9— 724/422, 6-9=-231/960, 6.8=-1021/417 NOTES 1) Wind: ASCE 7-10; VU11=140mph (3-second gust) Vasd=108mph; TCDL=4.2pst; BCDL=6.Ops1; h=15f1; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Exlerior(2) -1-4-0 to 4-8-0. Intenor(1) 4-8.0 to 23-2-5, Exteffor(2) 23-2-5 to 29-10-12 zone; C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This Iniss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0.0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Bearing at joints) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verity capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 16. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 329 lb uplift at joint 2 and 312 lb uplift at joint 16. 8) This truss has been designed for a moving concentrated load of 250.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 14" gypsum sheetrock be applied directly to the bottom chord. 10) Graphical purfin representation does not depict the size or the orientation of the purfin along the top and/or bottom chord. Q WARNWG • Vadly deslpn parameters and READ NOTES ON THIS AND INCLUDED AMTK REFERANCE PAGE Mp-7473 rev. 1010Z015 BEFORE USE. Design valid lot use only vAlh Mllek® corvnectots lhls design is based only uPon ryltarneters shown. and Is for an IndIvkkial building component not a buss system. Bolas trse, the building designer mast verily Ito appikablily of design momlers arid ixopetly incorporate 8t6 design Into the overall IxOding design. Bracing indicated Is to rxevenl budding of Individual inns wob and/or chord members only. Add liorial lempaary aril pennanenl tracing WOW is always iegtlied lot stablllly and to prevent collapse vAlh poss"o personal Wtay, and property, damage. Fa general guidance regarding the talxlcatlon, storage, delivery, election aril bocbng of trusses and Ins systems, weANSVFPII Cully Criteria, DSB-89 and SCSI Buliding Component 6904 Parks East Blvd Safety Information avallable from Iris Piste InstlMe. 218 N. Leo Sheel. State 312. AbexancM. VA 22314. Tampa. FL 33610 Job russ Truss Type oty Pry 738245 T106604t1 738245 A7 Piggyback Base 8 1 w Job Reference (optional nnl9 Dwww American Builders supply, winter naven,rrorldaxnmv •o+.w••••••••••••••••••••••••w•••• •••-••^•••---- ._,_. I D:r??OCSOkwZVhwYlOSTM4_yznGrl-s4lisLGKmDX007HudW924Y1r0ACCx_ahSVnOYzaScJ 7.10.73 1S•5-0 22.17.3 30.4.14 37.10.9 45.4.12 52.10.15 60.9.12 7-70.13 7.6.3 7.6.3 7.5-11 7.5 11 7 7 6.3 7./0.13 6x12 = 20 II 6x12 = Scale = 1:108.6 33 34 20 35 t9 183637 17 38 39 16 40 41 IS 4243 14 13 44 12 45 11 1 WO i 20 11 Sx6 = 40 = 7x8 = 4x4 = 40 = 20 11 40 = Sx6 = LOADING (psi) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2014/TPI2007 CSI. TC 0.68 BC 0.95 W B 0.94 Matrix-M) DEFL. in (loc) Wall Ud Vert(LL) 0,54 16-17 >999 240 Verl(TL) -0.86 15.16 >844 180 Horz(Q 0.33 11 We We PLATES GRIP MT20 244/190 Weight: 445 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x6 SP No.2 'Except' TOP CHORD Structural wood sheathing directly applied or 2.9.10 oc purlins, except 5-7: 2x6 SP 240OF 2.0E 4.0.0 oc pudins (5.4.13 max.): 5.7. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 20 SP No.3 WEBS 1 Row at midpt 4.17, 5-17, 6-16, 7-15, 8-15 REACTIONS. (Ib/size) 1=2249/Mechanical, 11=2249/Mechanical Max Horz 1=185(LC 12) Max UpIIII1=-1090(LC 8), 11=-1090(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-27-5202/4150, 2-27=-5116/4163, 2-3— 4494/3661, 3.28=-4420/3661, 4-28— 4354/3675, 4.5=•3739/3138, 5.29=-3622/3128, 6-29=-3622/3128, 6-30=-3622/3128, 7-30-3622/3128, 7-8=-3739/3138, 8-31=-4354/3675, 9-31=-4420/3661, 9.10=-4494/3661, 10-32=-5116/4163, 11-32=-5202/4150 BOT CHORD 1.33=-3781/4764, 1-34=-3781/4764, 20-34=-3781/4764, 20-35=-3781/4764, 19-35— 3781/4764, 18-19=-3232/4080, 18-36— 3232/4OBO, 36-37— 3232/4080, 17.37=-3232/4080, 17.38-2596/3398, 38-39=-2596/3398, 16-39=-2596/3398, 16-40-2581/3398, 4041=-2581/3398, 15-41=-2581/3398, 15.42=-3217/4080, 42-43=-3217/4080, 14-43=-3217/4080, 13-14=-3217/4080, 13-44=-3766/4764, 12-44=-3766/4764, 12-45=-3766/4764, 11.45-3766/4764, 11-46=-3766/4764 WEBS 2-20=-236/401, 2-19=-751/682, 4-19=-479/539, 4-17=-928/843, 5-17=-750/826, 5-16-336/600, 6-16=-449/300, 7-16=-336/600, 7.15=-750/826, 8-15-928/843, 8-13=-479/539, 10.13=-751/681, 10-12=-236/401 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUIt=140mph (3-second gust) Vasd=108mph; TCDL=4.2pst; BCDL=6.Opsf; h=15ft, Cat 11; Exp B; Encl., GCpf=0.18; MW FRS (envelope) gable end zone and C-C Exlerlor(2) 0.0.1210 6-0-12, Interior(1) 6.0-12 to 22-11-3, Extedor(2) 22.11.3 to 46-4.6, Interior(1) 46-4.6 to 60.9.0 zone; porch tell and right exposed;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) WARNING: This long span truss requires extreme care and experience for proper and safe handling and erection. For general handling and erection guidance, see Guide to Good Practice For Handling, Installing 8 Bracing of Metal Plate Connected Wood Trusses SCSI-1"), jointly produced by SBCA and TPI. For project specific guidance, consult with project engineer/archftecVgeneral contractor. MiTek or TRENCO assumes no responsibility for truss manufacture, handling, erection, or bracing. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0.0 wide will lit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1090 lb uplift at joint 1 and 1090lb uplift at WARNING • Verily design pararrretors and READ NOTES ON THIS AND WCLUDED MmrK REFERANCE PAGE IIBF7473 rev. 1a•CM15 BEFORE USE. Design valid for use only vAlh Wlek® Conneclois. it& design Is based only upon parameters shown, and Is for an Individual buldIng Componenl, not a atiss syslern. Before use. lie btdldhng designer mtfst verify the applicability of design parameters and property hncorporato IMt design Into the overall biddingng design. Bracing Indicated Is to prevent bucldhng of Individual truss web and/or chord members orgy. Additional temporary and permanent bating WOW Is always te%dred for stalltllly and to proven) collapse with possible personal Wiry and property damage. For general gtddance reoaldN the falxkafkxn, storage. delivery. erection and IxocbV of masses and Russ systems. seeANSI/1PI I Cuo9ty, Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information ovaltahfe from trust Plate Instlfrfte. 218 N. lee Street. Sulto 312, Alexandria. VA 22314 Tampa, FL 33610 Job- I rush TFuss Type oty Ply 736245 710660411 738245 A7 Piggyback Base O Job Reference (optional) AreenCen aarrosFs sWP%• winter maven. rwrwo o,waa- ID:r??OCSOkwZVhwYIOSTM4_yznGfi-KHs43hHyXXTF1 HDrSLIObl4ubOWRxNDkvoEKw_zaScl NOTES- 9) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other five loads. 10)'Semi-rigid pitchbreaks with fixed heels' Member end fixity model was used In the analysis and design of this truss. 11) Graphical puffin representation does not depict the size or the orientation of the puffin along the top and/or bottom chord. 0 WARNING • Vodly design paramoton and READ NOTES ON THIS AND INCLUDED NREK REFERANCE FADE N* 7473 rev. I66MIS BEFORE USE. Design valid lot use orgy vAth Wlek® connectors. Irgs design Is based orgy upon pmanelers shown. and Is for an hdlvkAral bidding component. not a buss system. Before use. the iddng designer mtal vedh' the applicability of design parameters and IroperlY hcorpaate this design Into the overall budding design. Wachg Indicated h to prevent bucldt ng of IndNklrral lniss web and/or chord members only. Additional lempaay and permanent bracing MiTek' Is always iegtbed for stability and to prevent collapse vAth possible personal hluy and properly damage. For general gtddance regarding the lobilcallon, storage. delivery, cvecflon and bracing of Inlsses aril Russ systerns. weANSI/TPI I Quality Cdterla, DSO.89 and SCSI Building Component 6904 Perks East Blvd Safety Information available Rom lnm Nale hstltule. 218 N. lee SRaet. Suite 312. Alexandria. VA 22314. Tompa, FL 33610 Job runs Truss Type oty ply 736245 T106604t2 738245 B1 GABLE B t Job Reference tional AlnerrCan MIME 4UPP9. nmter Woven. rgwo...___... xx__...._ _ _ ID:r??OCSOkwZVhwYIOSTM4_yznGrl-KHs43hHyIFIHDrSL1Obl4 rOfOxaTkvoEKw zaSel 1.4-0 3.8-0 7.4-0 21:0 1.4-0 3.8-0 3.8-0 1 d-0 40 = Scale. 1:19.0 la 30 = LOADING SPACING- 2-0-0 CSI. DEFL. in poc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.28 Verl(LL) 0.02 6-14 999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.33 Verl(TL) 0.02 6-14 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.10 HOrz(TL) 0.00 4 n/a We BCDL 10.0 Code FBC2014/TP12007 Matrix-S) LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 WEBS 20 SP No.3 OTHERS 2x4 SP No 3 REACTIONS. (lb/size) 2=344/0-3-8, 4=344/0-3-8 Max Harz 2=40(LC 16) Max Uplitt2= 174(LC 8), 4=-174(LC 9) Max Grav2=405(LC 27), 4=405(LC 39) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3— 365/433, 3.4_ 365/433 BOT CHORD 2-19=-247/324, 6-19=-247/324, 6-20=-247/324, 4.20=-247/324 WEBS 3-6=-143/254 PLATES GRIP MT20 244/190 Weight: 31 lb FT = 20%6 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. NOTES- 1) Unbalanced rool live loads have been considered for this design. 2) Wind: ASCE 7-10; VU11=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.0psf; h=1511; Cat. 11; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Comer(3) zone; cantilever left and right exposed; porch left and right exposed;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qua111ied building designer as per ANSVTPI 1. 4) Gable studs spaced at 2.0.0 oc. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0.0 wide will lit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 2 and 174 lb uplift at joint 4. 8) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and Y4" gypsum sheetrock be applied directly to the bottom chord. Q WARNING - Verily design parameters end READ NOTES ON TN1S AND INCLUDED mrrEK REFERANCE PAGE M1167473 rev. 1&0"016 BEFORE USE. Design valkl for use only with Mllek® connectors. Ihh design Is based only upon parameters shown, and Is la an L dlMdrud building component, not a Cuss systom. Before use. the txdldlnp designer must verily the apitlk;ablity of design parameters and property Itaoq)orole this design Into the overall building design. Bating Indicated Is to lxevent buckling of Individual Irus web and/or chord members only Addtlonal temporary and permanent biacing MiTe k' 6 always requlied for stability and to prevent collapse wllh possUe personal bhhay and rxoperty damage. For general guidance regading TO lalxk;allon storage. delivery, erecllon and Ixacklg of trusses and trim systems seeANSI/FPI I CuaBly Cdfoft, D$8-89 and BCSI 8ullding Component 6904 Parke East Blvd. Safety Information avaMlble from bus Rate Institute. 218 N. lee Steel. Suite 312, Alexandria, VA 22314. Tampa. FL 33610 Job russ Truss Type Qty ply 738245 T106604t3 738245 82 Common 16 1 1 Job Reference o Gonal uT. r..w...•.:.. .... Tr,., u"..e na•vree 0n17 vnn. t rnencan verroes ouppry, mmm nerm•. v.w.v —vv - - -- - - ID:r??OCSOkwZVhwY108TM4_yznGrl-oTOSH1 lalrn6f Ro102Yd7Vd9bq?Fg t jt8S_uTRzaScH 1.4.0 3.8-0 7-4-0 e-B-0 1.4-0 3-8-0 3-8-0 1.4-0 40 = 30 = Scale = 1:19.0 la LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in loc) Vdetl Ud PLATES GRIP TCLL 20. 1 Plate Grip DOL 1.25 TC 0.28 Vert(LL) 0.02 6.10 999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1,25 BC 0.33 Ver(TL) 0.02 6-10 999 180 BC LL 0.0 ' Rep Stress Incr YES WB 0.10 Horc(rL) 0.00 4 We n1a BC DL 10.0 Code FBC2014lrP12007 Matrix-S) Weight: 29lb FT = 20°b LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (Ib/size) 2=344/0.3.8, 4=344/0-3-8 Max Horc 2=40(LC 16) Max Uplitt2=-174(LC 8), 4=-174(LC 9) Max Grav2=405(LC 27), 4=405(LC 39) FORCES. pb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-365/433, 3.4=-365/433 BOT CHORD 2-15=-247/324, 6-15= 247/324, 6.16= 247/324, 4-16= 247/324 WEBS 3.6=-143/254 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUII=140mph (3-second gust) Vasd=108mph; TCDL=4.2pst; BCDL=6.0psf; h=1Sit; Cat. It; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Comer(3) zone; cantilever left and right exposed; porch tell and right exposed;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Ops1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will tit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss 10 bearing plate capable of withstanding 174 lb uplift at joint 2 and 174 lb uplift at joint 4. 6) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and YZ" gypsum sheetrock be applied directly to the bottom chord. WARNING - Verily dedgn parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE 61/1-7473 rev. 140=15 BEFORE USE Design valid for use only with Mllek®connoclors. Ills design Is based only upon paameters shown, and Is fa an Individual building component. nor a buss system. Beforo use, the bxdld ing designer must verify the applicability of design p alatneters and properly Worpaate 0% doslgn Into tho overall Additional lempotary and pwmanenl tracing WOWbridingdesign. Biocing Indicated Is to prevent bucldIng of IndIviclual Irtas web and/or chord members only. Is always recpulred lot stablilly and to prevent collapse with possible personal IMry and property damage. For general guidance tegarding the fabrication. storage. delivery. eiecllon arxl [racing of musses and inm systems. sdwANSI/TPI I Quality Crltedo, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Tango. FL 33610 Safety Information available tram ltuss Plate Inslilute. 218 N. lee Street. Sully 312. AlexarvJrla. VA 22314. Job TFUSS Truss Type oty Ply 739245 Tt06fiO4t4 738245 83 Common Geder B e L 1 Job Reference (optional) AmencCan 9u110019 soppy, wtnrer Haven, rraroe a.wev ID:r??OCSOkwZVhwY108TM4_yznGrl-HI_gUNJC38vzHbNDZm3sgjAMIDK5PRYON6jn?tzaScG 1.4.12 3.7.4 7.2-8 B•7.4 1.4.12 3.7.4 3.7.4 1.4-12 Scale = 1:21.9 40 = r9R 20 11 20 11 LOADING (psf) SPACING- 2.0.0 CSI. DEFL. in loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.13 Veri(LL) 0.01 7-8 999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.42 Vert(R) 0.02 7.8 999 180 BCLL 0.0 ' Rep Stress Incr NO WS 0.32 Horz(TL) 0.00 6 We Na BCDL 10.0 Code FBC2014/TP12007 Matrix-M) Weight: 100lb FT = 20%, LUMBER- BRACING - TOP CHORD 2x4 SP N0.2 TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc puffins, except BOT CHORD 2x6 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 1-1-4 except (jl=length) 9=0-3-8, 7-_0-3.8. Ib) - Max Horz 10=-52(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 10= 238(LC 4), 6=-240(LC 5), 9=-990(LC 4), 7=-981(LC 4) Max Grev All reactions 250 lb or less at joint(s) except 10=459(LC 1), 6=465(LC 1), 9=2115(LC 1), 7=2097(LC 1) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2.3=-1709/829, 3.4_ 1709/829, 2.10= 1445l709, 4-6=-1445l709 WEBS 3-8=-579/1165,2-8=-768/1654,4-8=-768/1654 NOTES- 1) 2-ply truss to be connected together with 10d (0.131'XW) nails as follows: Top chords connected as follows: 20 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6.2 rows staggered at 0-5.0 oc. Webs connected as follows: 20 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face In the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2pst; BCDL=6.Opsf; h=1511; Cat. II; Exp B; Encl., GCpl=0.18; MW FRS (envelope) gable end zone; end vertical left and right exposed; porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1 60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSVTPI 1. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 238 lb uplift at joint 10, 240 lb uplift at joint 6 990 lb uplift at joint 9 and 981 lb uplift at joint 7. 10) This truss has been designed for a moving concentrated load of 250 Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 11) 'Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used in the analysis and design o1 this truss. 12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2229 lb down and 1110 lb up at 2-5-7, and 2229 lb down and 1110 lb up at 4-8-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Q WARNING - Verily daWfin prnmofom and READ NOTES ON THIS AND INCLUDED NREK REFERANCE PAGE M67473 rov. ISVXWIS BEFORE USE. Doslgn v.k1 For use only v4th Mllek®conneclas. "design Is based only upon paranelers shown. and Is for an IndivkArd bolding component nol a Was system. Belote trio, rho building deslgnor mint verity the appllcaLtliy, of design parameters and properly Waiporato this design Into the over.' btAding design ®acing Indicated Is to pevenl Ixrcidbhg of Indlvkftral truss web and/or chord members only. Additlonrll lemlwrary and permanent brocbtg M iT.ek' 6.ways impked to slab91ty and to prevenl coticpse wllh possible personal Iniury and popany damage• rot genoal guldahce regarding the krtxicatlon. storage. delivery, erection aryl bracing of trusses and inns systems, seeANSI/Tpll Quality Criteria, DSB-89 and SCSI BuUftg Component 6904 Parke East Blvd. safety Information available bon bras Plate Inslltute. 210 N Loa Streel. SWIe 312. Aloxandria. VA 22314. Tompa. FL 33610 Job rush Truss Type ty P y 7382R5 Tt0660414 73e245 83 Common Girder 9 e L tionalJobetereneeo LAn J1r. mG I •5 9mf7 Dwn'J Amerman BYrraere Supply. winter maven. frorraa JJeev .,.---- 1..___._.._.__...___.-_-_.--__ ------ I D:r??DCSOkwZVhwYlOSTM4_yznGrl-Hf_q UNJC38vzHbN DZm3sgjAMIDK5PRYON61 R?tzaScG LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vern 1.2= 54, 2-3=-54, 3-4=-54, 4-5=-54, 6-10=-20 Concentrated Loads (lb) Vert: 12=-2229(B) 13=-2229(B) Q WARNWG - VwNy doelyn parameters and READ NOTES ON TIBS AND WCLUDEO NrrEK REFERANCE PAGE ND7473 rev. IMW IS BEFORE USE Design valid lot use orgy with Mllek® connectors. Ihls design Is lased orgy upon Imamelers shnown, and Is lot an Indmducd binding component. nor o Was syslein. Before uso. the txDding designer rntist verity the aWIcalAlN of design laramelers and properly incorporate this design Into the overall 1x0dtng design. machg Indicated K to prevent buckling of IrKfWtxg Iruss web and/or chord membets orgy Addtlonal temporary and permanent bracing M iTe k' Is always recpbed rot statAlly and to prevent collapse vAth poss"o personal I fury and properly damage. For general guidaoe regarding the fabricatlort, storage, delivery, erectkxn and Ixcrcfrng of Inasos and Inns systems seeANSI/TPIT Cuailly C4tedo, D$11-89 and I1CSI BulklIng Component 6904 Poke East Blvd. safety =Motion ovdlable from buss Plate Inslikile, 218 N. Lee Stroet. Suite 312. Alezanddo. VA 22314. Tampa. FL 33610 Job Truss Truss Type oty Ply 738245 Tt0660415 736245 CJ1 Jock -Open 6 1 Job Reference o Lionel r.... Tr... u... m nc De -AK inn Dnn. i AmeIKOn Bur Idols Supply. Wolof noven, I D: r??OCSOkwZVhwYIOBTM4_yznG rl-Hf_gU NJC38vzHbN DZm3sgjALhDODP VTON61 R?tzaScG 1.4-0 1-" 1.4-0- 1-0_0 Scale = 1:6.8 30 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in Qoc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) 0.00 5 999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(TL) 0.00 5 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0,00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC20141TP12007 Matrix-M) Weight: 5 lb FT = 20% LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 REACTIONS. (lb/size) 3=3/Mechanical, 2=147/0-8.0, 4=-SJMechanical Max Horz2=40(LC 12) Max Uplift3=-2(LC 12), 2=-83(LC 8), 4=-5(LC 1) Max Grav3=7(LC 3), 2=147(LC 1), 4=14(LC 8) FORCES. Qb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; Cat. 11; Exp B; Encl„ GCpi=0.18; MW FRS (envelope) gable end zone and C-C Corner(3) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL= 1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will lit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2 lb uplift at joint 3,83 lb uplift at joint 2 and 5 lb uplift at joint 4. 6) ' Semi -rigid plichbreaks with fixed heels' Member end lixity, model was used in the analysis and design of this truss. Q WARNING - Verily doWtn pwameron and READ NOTES ON THIS AND INCLUDED MftEK REFERANCE PAGE MF7177 MV. 1493MIS BEFORE USE Design valid to use only with MlleM connectors. Inls design is based only upon paa metem stwwn. and Is lot an Individual building component, not a truss system Beloto use. the building designer must verify the applicability of design MOnfelors arnl Ixolxrty h1COrl0101e IhIS design Into the overall brltdng design. Brocing Indicated Is to prevent buciding of Individual truss web and/of chord members only. Addllonal lemporary and permanent bracing WOW Is always required for stability and to prevent collapse vAlh possible personal IVW and property damage. Rx general guidance fogadhng the labrk; atbn. storage, delivery, election and bracing of inrsses and Iniss syslems, weANSI/IPI I Cuatify Criteria, DSO-89 and SCSI Wilding Component 6904 Parke East Blvd. Safety Information available horn If= Plate Institute, 218 N. foe Street. Suite 312, Alexandria. VA 22314. Tomps. FL 33610 Job Truss Truss Type 738245 Tt0660416 738245 CJ3 Jack -Open 10tya 1 Job Reference o Uonal tM Tx.. u.. — nt: *. Ac 9nt7 Pwnw t AmetKan outraere Juppy. warner never. nonce oaoov ID:r??OCSOkwZVhwYIOSTM4_yznGrl-ISYCi1JggS1quyO7Ta5DwiWRdm68yjAemT XJzaSeF 1.4.0 3." 14.0 3-" 20 = LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in loc) Well Ud TCLL 20.0 Plate Grip DOL 1,25 TC 0.20 Vert(LL) 0.00 7 999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.05 Vert(rL) 0.01 4-7 999 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a rl/a BCDL 10.0 Code FBC2014lrP12007 Matrix-M) LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 REACTIONS. (lb/size) 3=57/Mechanical, 2=205/0-8-0, 4=27/Mechanical Max Harz 2=76(LC 12) Max Uplift3=-43(LC 12), 2=-75(LC 12) Max Grav3=57(LC 1), 2=205(LC 1), 4=44(LC 3) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 pb) or less except when shown. Scale = 1:11.1 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3.0-0 oC pudins. BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. NOTES- 1) Wind: ASCE 7-10; VUlt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf,, BCDL=6.Opsf; h=1511; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Corner(3) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43lb uplift at joint 3 and 75 lb uplift at joint 2. 6) 'Semi -rigid pitchbreaks with lixed heels' Member end fixity, model was used in the analysis and design of this truss. 0 WARNING - Verify design penmetem and READ NOTES ON THIS AND INCLUOEO MrrFK REFERANCE PAGE A07473 rov. l aV302015 BEFORE USE. Deslgn vall d for use only vAlh W lek® connectors. lids design 6 based oNy u pm parameters shown, and Is lot an Indh kAral butdi ng component. not a Miss system. Before tore, the building designer must verily Iho applicability of design puvameters and property hcotpotale this design Into the overall Addlllortal temporary and permanent boating MiTek' b/ding design. Bracing indicated Is to prevent buciding of Individual Intss web and/or chord members orgy. Is always regutied lot slotAlly and to prevent collapse with possible personal Wtey and p ioperty damage. For goneral guidance regarding the IaMk:c lion. storage. dellvety. erection and txoolng of intsses and Intss syslmns. woANSIMI I Quality Criteria, DS8-69 and BCSI Building Component 6904 Parke East Blvd. Safety Information avdWble torn Truss Rote Institute. 218 N Leo sboet. StAlo 312. Alexandria. VA 22314. Tango, FL 33610 Job Truss Truss I ype Oty Ply738245 T10660417 738245 CJS I'ack-Open 8 1 Job Reference (optional) American aurlflers supply. wMier Moven. Fiemae 3JeeV ..v.v.-v,. v^T. • ._,_. ID r110CSOkwZVhwYlOOTM4_yznGrl-ISYCi)JggSlquyO7Ta5DvAV1dkJ8y)AcmT XJzaSeF 5.0-0 1 4.0 - - 5.0.0 , 2x4 = LOADING (psi) SPACING- 2-0.0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 TCDL 7.0 Lumber DOL 1.25 BC 0.17 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2014lrP12007 Malrix-S) LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 REACTIONS. (lb/size) 3=1 01 /Mechanical, 2=292/0-8-0, 4=44/Mechanical Max Horz2=114(LC 12) Max Up11113— 78(LC 12), 2=-97(LC 12) Max Grav3=101(LC 1), 2=292(LC 1), 4=74(LC 3) FORCES. (Ib) - Max. Comp./Max. Ten.. All forces 250 (lb) or less except when shown. Scale = 1:15.3 DEFL. in poc) Well Ud PLATES GRIP Verl(LL) 0.02 4-7 999 240 MT20 244/190 Verl(TL) 0.04 4.7 999 180 Horz(TL) 0.00 2 n/a We Weight: 18lb FT = M0 BRACING - TOP CHORD Structural wood sheathing directly applied BOT CHORD Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10; Vull=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpl=0.18; MW FRS (envelope) gable end zone and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions shown, Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0-0 wide will lit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 78 lb uplift at joint 3 and 97 lb uplift at joint 2. 6) This truss design requires that a minimum of 7/16' structural wood sheathing be applied directly to the top chord and W gypsum sheetrock be applied directly to the bottom chord. wARNWG . Verily design par4merore and READ NOTES ON THIS AND WCLUDED MITEK REFERANCE PAGE NIF7473 rev. 109302015 BEFORE USE. Design valid for use only wllh Mllek® connectors. INs design E based only ut»r1 paameters shown. and Is for an Individual Wilding component. not a lims system. Before use. the LxdldIng designer must verily the opplIcaWlly of deslpn parameters and properly incorporale this design Inlo The overall IxBdIng design. BrachU Indicated Is To prevent Ixrckling of Individual Inrss web and/or chord members only. Addillonal Temporary and permanent black* WOW It always required la staWlly and to Ixevenl collapse wllh possmle personal In W and property damage. For general guidance regarding Brie storage, delivery. erectlon and bracing o1 Trusses and truss system& X*ANSI/IPI I Quality Crilerlo. DSB-89 and SCSI SulmIng Component 6904 Parke East Blvd. Safety IMamollon ovdiloble from Truss Plate Institute. 218 N. lee Street, Sullo 312. Alexandria. VA 22314. Tempo. FL 33610 Job Truss Truss Type ty 738245 T10660418 738245 EJ7 Jack -Open 4 1 s..n-w. Job Reference o ironal e ,n.e wT.L r..A........ 1.... Tn,. LM, f. nR 7I•77n17 Pnnwt American Builders supply. winter Pleven. Peondo 3J**V-- ID:r11DCSOkwZVhwYlOSTM4_yznGrl-D26bv3KTbm9hWvXchB5KISFe31 t8tPzJgOCY3mzaSeE A-4.0 7.0-0 1.4-0 7.0-0 Scale = 1:19.6 3x4 = 7.0-0 7-0-0 Plate Offsets MY) 12:0.1 2 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. In poc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.40 Verl(LL) -0.18 4-7 >470 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(Q -0.27 4-7 >304 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 2 n/a n1a BCDL 10.0 Code FBC2014lrP12007 Matrix-S) Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 20 SP No.2 BOT CHORD Rigid ceiling directly applied. REACTIONS. (lb/size) 3=144/Mechanical, 2=382/0.8-0, 4=60/Mechanical Max Horz 2=151(LC 12) Max Upllll3=-112(LC 12), 2=-120(LC 12) Max Grav3=144(LC 1), 2=411(LC 25), 4=303(LC 27) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (Ib) or less except when shown. BOT CHORD 2-9=-835/1371 NOTES- 1) Wind: ASCE 7.10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opst; h=1511; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Extedor(2) -1.4-0 to 4.8.0, Interior(1) 4-8.0 to 6.11-4 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.OpsI on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will lit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift at joint 3 and 120 lb uplift at joint 2. 6) This truss has been designed for a moving concentrated load of 250.0Ib live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 14" gypsum sheetrock be applied directly to the bottom chord. 0 WARNING - Verity des/pn parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE w7473 rov. 1603 V I S BEFORE USE. Desim valkl lof use orgy vAlh Milek® connectors. tints design Is based orgy upon parameters shown, and Is for an trndlvkAral building component. rot a Olin bsystem. Belore use. the uildtrng designer must verity the apolcabllly of design "amelans aril Ixoporly tricapoiate this design Into the overall Ac"llonal lempaay and Immanent bracing WOWbuildingdesign. Bating Indicoled Is to prevent bucklbV of Individual truss web and/or chord members only. It always required for stability and to Ixevenl collapse wllh possible personal trN+Y and lxopeny damage. For general guidance iegosding tine kAxlcallon, storage, delivery, orecibn and bracing of Irtmes and him systems. seeANSI/IPI I Quality Criteria. DSB-89 and SCSI Building Component 6904 Pork* East Blvd. Tempo, FL 33610 Salary Information available kom Olin Plate Institute. 218 N. Lee Street. Sulle 312, Alexandria. VA 22314. ob Truss Truss Type City Ply 738245 T106604t9138245EJ9JACK -OPEN 44 t Job Reference (optional) n 1 Dwn AFF19man ourraers ouppry. rvmler nvven, rgnve .a.wov..-_--..r.._-_._.._._.._..___...__._.._ _ _ - ID:r11OCSOkwZVhwY108TM4_yznGrl•D26bv3KTbm9hWvXchB5K18F1w1 xttOCJgOCY3mzaSeE 5.4.3 9-0.0 5.4-3 3.7.13 3x9 = 30 = LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Veri(LL) 0.31 6.9 342 240 TCDL 7.0 Lumber DOL 1.25 BC 0.67 Ven(TL) 0.52 6-9 207 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.11 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC2014/TP12007 Matrix-S) LUMBER - TOP CHORD 20 SP N0.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (Ib/Size) 4=72/Mechanical, 2=435/0-8-0, 5=227/Mechanical Max Horz2=188(LC 12) Max Uplift4— 63(LC 12), 2=-116(LC 12), 5=-80(LC 12) Max Grav4=72(LC 1), 2=441(LC 26), 5=356(LC 25) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-10-3151137 BOT CHORD 2- 11-303/1708, 2.12=-27t3/264, 6.12=-278/264 WEBS 3.6=- 311/327 Scale, 1/2'= T PLATES GRIP MT20 244/190 Weight: 36 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. NOTES- 1) Wind: ASCE 7-10; VUlt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psh BCDL=6.opsl; h=1511; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Extedor(2) -1-4-0 to 4-8.0, Interior(1) 4-8.0 to 8-11.4 zone;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.(>0 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will lit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 63 lb uplift at joint 4, 116 lb uplift at joint 2 and 80 lb uplift at joint 5. 6) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 7) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and *"gypsum sheetrock be applied directly to the bottom chord. Q WARNING - yed/ y dadyn peramerere and READ NOTES ON THIS ANDWCLUDED MrTEK REFERANCE PAGE MA7473 rov. IO'MOIS BEFORE USEDesign valid la use only vAlh Wlek®conneclon. Itds design Is Iced only upon "amelets shovn', andis lot an Individual tAAdhng component not a flboss system. Below use, the ildIngdesignermustveritytheapplkcANlryparametersaiOfdesigndpropertyIncorporatethisdesignIntotheoverdlbuildingdesign. Bracing Indk:ated Is to txevenl brckWV of IrndNklucd truss web and/or chord members only. Addlllonal lempotory and permanent Ixacing WOW It always recRdred for stability and to txevent collcrw with possible personal h W and property damage. For genetal guidance tegadlng the fdxlcatlon, storage. delivery. eroctlon and Mating of trusses and Inns systerms. WeANSIffPI I Quality Critoda, DS5-69 and SCSI Building Component 6904 Parke East Blvd. Safety Infarmatron avdlablo Dom Russ Rate Institute. 218 N. Leo Sheet. Suite 312. Alexandria. VA 22314. Tampa. FL 33610 Job T russ Truss Type Oty Ply 738245 710660420 738245 HP Diagonal Hip Glider 4I 1 Job Reference (optional) C•JA w0 Tar) Dwn American Builders supply. winter Haven. Ylorrao JWVV .., - -1... ...... ..-..-•-...___...-_. ..._. I D:r??OCSOkwZVhwYlOSTM4_yznGrl-hEgz6PL5M3HY626oEucZlLnrORNdcpVT34y5cCzaScD t-10.10 5.10.6 9.10.1 1.10.10 5.10.6 3.11.11 Scale = 1:22.7 2x4 = 3x4 = 5.10.6 941-9 5.10-6 3.10-3 0.1.8 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. In pot) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Ven(LL) 0.02 7-10 999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.31 Vert(TL) 0.06 7-10 999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.24 Horz(TL) 0.01 6 We n1a BCDL 10.0 Code FBC2014RP12007 Matrix-M) Weight: 41 lb FT = M0 LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP No.2 WEBS 20 SP No.3 REACTIONS. (lb/size) 4=93/Mechanical, 2=407/0.10-15, 6=304/Mechanical Max Horz 2=162(LC 22) Max Uplilt4=-71(LC 4), 2=-217(LC 4), 6— 89(LC 8) Max Grav4=93(LC 1). 2=478(LC 19), 6=304(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-11=-606/155, 11-12=-594/160, 3-12=-564/166 BOT CHORD 2.14— 240/570, 14-15= 240/570, 7-15= 240/570, 7.16_ 240/570, 6.16= 240/570 WEBS 3-6=-627/265 NOTES- 1) Wind: ASCE 7.10; Vull=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads. 3) - This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 4, 217 lb uplift at joint 2 and 89 lb uplift at joint 6. 6) 'Semi -rigid pitchbreaks with fixed heels' Member end fixity model was used In the analysis and design of this truss. 7) Hanger(s) or other connection devlce(s) shall be provided sufficient to support concentrated load(s) 72 lb down and 57 lb up at 1-6.1, 72 Ib down and 57 Ib up at 1-6-1, 23 Ib down and 35 Ib up at 4.4-0, 23 Ib down and 351b up at 4-4-0, and 40 Ib down and 78lb up at 7.1-15, and 40 Ib down and 78 Ib up at 7.1.15 on top chord, and 151b down and 9 lb up at 1-6-1, 15 Ib down and 9 Ib up at 1.6.1, 5 Ib down and 1 lb up at 4-4-0, 5 lb down and 1 lb up at 4-4-0, and 20lb down at 7-1-15, and 20 lb down at 7-1-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the lace of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase--1.25, Plate Increase=1.25 Uniform Loads (pit) Van: 14=-54, 5-8=-20 Concentrated Loads (Ib) Vert: I1=113(F=57, B=57) 13=-49(F=-25, B=-25) 15=-9(F=•5, B=-5) 16=-32(F=-16, B=-16) Q WARNING. Verily d@Wgn porametem and READ NOTES ON THIS AND INCLUDED Nr7EN REFERANCE PAGE Mll-7473 rov. IM302015 BEFORE USE. DWJgn valid for use only with Mllek® connectors. tNs design Is lxsed only upon paameters shown. and Is for an Individual bu0ding component. not o truss system. Belore lose, the lxllclaV designer must vedy, the opplicc"Ity, of deAp Mameters and plopelly Incorpotale Ihb design Into the overall btOding design. Biacing Indicated b to rxevent bucldirtg of h,dfvlducj If m web and/or Chad members only. Additional lemporary and permanent Ixacing M iTek' Is always rest lied la stalAlly and to prevenl collcgxe with possMe personal InMy and rxoperly domage• For general gt*kF)ce ragarcing the Wlxlc(ril u staago, delivery, ereCllon and brachtg of intros cord tnrst systems. SeeANSIMI I Quality Criteria, DSB-89 and SCSI Bullding Component 6904 Polka East Blvd Safety IMormallon ovaltable from Irt= Role Inslllute. 218 N Leo Street. Sulle 312. Alexa cM. VA 22314. Tampo, FL 33610 Job Truss Truss Type ty 8245 T1066042tljb 730245 MGt Ho" Hip Girder 4 t Reference o tional Mlenrten Hulloore Supply, w mrer.oven. mma oxev ....,.ow••o.,,•••••-•- -. ...- ..._.._. .___._. .___.. _v_. I D:r??OCSOkwZVhwY108TM4_yznGr I-9RDLKIMj 7N PPICh?ocBogZK_2rZeLGdcl khf8ezaScC 1.4-0 7-0.0 B-0-0 7-0-0 2-0-0 40 = 4xa = 20 It 7.0-0 tt-0-0 7-0.0 2-" Scale = 1:22.2 Plate Offsets (X,Y)•- 12:0-2-2 Edge] 13.0.5-0 0-2-01 LOADING (psi) SPACING- 2.0-0 CSI. DEFL. in loc) Vdell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.43 Veri(LL) 0.13 6-9 809 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Verl(TL) 0.20 6.9 528 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.25 HOrz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2014/TP12007 Matrix-M) Weight: 42 lb FT = 20% LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD BOT CHORD 20 SP No.2 WEBS 20 SP No.3 BOT CHORD REACTIONS. (Ib/size) 2=516/0-8.0, 5=615/Mechanical Max Horz2=153(LC 8) Max Uplift2= 174(LC 8), 5=-218(LC 8) Max Grav2=516(LC 1), 5=642(LC 25) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown TOP CHORD 2-3=-480/110 BOT CHORD 2-10=-507/1202, 2-11=-146/377, 6-11=-146/377, 6-12=-148/399, 5-12=-148/399 WEBS 3-6=-32/645, 3-5=-752/279 Structural wood sheathing directly applied or 5.6.2 oc pudins, except end verticals. Rigid ceiling directly applied or 10.0.0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psh BCDL=6.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will lit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 2 and 218 lb uplift at joint 5. 7) This truss has been designed for a moving concentrated load of 250.Olb live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other live loads. 8) 'Semi -rigid pitchbreaks wilh lixed heels' Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 90 lb down and 114 lb up at 7-0.0 on top chord, and 315 lb down and 105 lb up at 7-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert: 1-3=-54, 3.4=-54, 5.7=-20 Concentrated Loads (Ib) Vert: 6=-315(B) 3=-90(B) Q WARNING - Vorlly dodyn pitremoters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE UP-7473 rev. 10022016 BEFORE USE. DesIM Vatic! for use only vAth WOW oonneClas. Rtls design Is based only upon 1':arameters shown. and Is for an hdMduat building cornporxml, not a buss system. Before use. Itio building designer rnusl verity the applicability of design gxxorneters and popery bncowiale this design Into Ilia overall building design. Bracing Irxilcated is to prevent bmidtrig of IndMdual truss web and/or chord members only. Additional lempaary and pemanenl bracing M ITek' is always tecalred for stability and to pevent collcpso with posslile personal Iryuy and property damage. For general guidance regarding 8ne fablcatlon, storage. dotivery. eiec lion and bracing of trusses and tnm syslerns, soeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Pmke East Blvd. Safety Information avdlahle floin truss Rate Institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314 Torripa, FL 33610 Fuss Truss Type oty ply 739245 T10660e22 738245 Pat PIGGYBACK 176 t Job Reference o ironal I n o e•ep 2017 v 1 American BYlldeq SuppN. W inter Haven. Fbrrdo 33980 76 s Apr to 2016 lv4Tek Industries. nc. T u Mot 16 6.2 . aps I D:r??OCSOkwZVhwYlOSTM4_yzn(3r l •9R DLKIMj7N PPICh?ocSogZKyxrhjLJSclkhf 8ezaScC Scale = 1:18.3 20 11 5 2X4 = 2x4 11 7./•11 7.1.11 LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in hoc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.01 4 n/r 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(TL) 0.01 4 FVr 120 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 Na n1a BCDL 10.0 Code FBC2014lrP12007 Matrix) Weight: 24 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc purlins, except BOT CHORD 2x4 SP No.2 end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid telling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 5=243/6-0-6, 2=254/6-0-6 Max Harz 2=128(LC 12) Max UplifiS= 112(LC 12), 2=-65(LC 12) FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; VUlt=140mph (3-second gust) Vasd=108mph; TCDL=4.2psi; BCDL=6.Opsi; h=1511; Cal. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Exlerlor(2) 0-5-7 to 6-5-7, Intenor(1) 6.5.7 to 7-5-11 zone;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psi on the bottom chord in all areas where a rectangle 3.6-0 tall by 2.0.0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 112 lb uplift at joint 5 and 65lb uplift at joint 2. 6)'Semi-rigid pitchbreaks including heels' Member and fixity model was used In the analysis and design of this truss. 7) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. WARNING • Verify dedyn parameters and READ NOTES ON THIS AND INCLUDED Mr7EK REFERANCE PAGE M/F7473 rov. 1411132016 6EFORE USE Design valkf for use only Win Mltek® connectors. this design Is Iwsed orgy upon paramelers shown. and Is for an Individual building component. not a Into system. Before use, the building designer must verily the) applicablilly of design parameters and properly incotlorole It & design Into the overall building design Bracing indicated Is to prevent luclding of individual truss web and/or chard members only. Additional lempotary and permanent bracing M iTek' Is always togtdred for stability and to prevent collapse wllh posse personal Iryuy and properly damage. For general guidance regarding the fabricatkm, storage. delivery. erection and Mating of trusses atxl Inns systems. seeANSI/IPI I Quality Crlloda, OSS-89 and lCSI Building Component 6904 Parke East Blvd. Safety Information avdlatNe from true Plate Institute. 218 N. lee Sheet. Sidle 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type oty Ply 738245 T10660423 738245 PB2 Piggyback 9 1 Job Reference o ironal n nn.e rr-,. ,-..-...-- ,-- Tom.. -. e ne..f.CM 9n,7 Dwww American vulraera .lupply. W ime, RDVan, •w- ._ ...__ . _ --,- _ _ -- I D:r??OCSOkwZVhwY108TM4_yznGrl•ddnjX4NLuhXGNMGBMJf 1 Nmt82E 1 s41ZmW ORCg4zaScB 7.5.11 14.11-6 7.6.11 7-5.11 Scale = 1:25.5 06 = 30 = 6 30 = 20 11 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.48 Vert(LL) 0.03 5 Nr 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0,39 Ven(TL) 0.05 5 rt/r 120 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 4 We n1a BCDL 10.0 Code FBC2014/TP12007 Matrix) Weight: 46lb FT = 20% LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 2x4 SP No.2 OTHERS 20 SP No.3 REACTIONS. (lb/size) 2=243/12.8.13, 4=243/12-8-13, 6=526/12-8-13 Max Horz 2=57(LC 12) Max Uplitt2=-96(LC 12), 4=-106(LC 13), 6— 86(LC 12) Max Grav2=249(LC 23), 4=249(LC 24). 6=526(LC 1) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 pb) or less except when shown. WEBS 3-6=-337/234 BRACING - TOP CHORD Structural wood sheathing directly applied or 6.0.0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vull=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.0psf; h=1511; Cat. 11; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Extedor(2) 0-5-7 to 6-5-7, Interior(1) 6-5-7 to 7-5-11, Exterfor(2) 7-5-11 to 13-5-11 zone;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 96 lb uplift at joint 2,106 lb uplift at joint 4 and 86 lb uplift at joint 6. 7) 'Semi -rigid pitchbreaks Including heels' Member end fixity model was used in the analysis and design of this truss. 8) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. WARNING. Vedry dodgn panmafoni and READ NOTES ON 7N1S AND WCLUDED MREK REFERANCE PAGE MD-7473 rev, 14119 I S BEFORE USE Design vtlkl for use ordy with liAlek® connectors. Ms design 61xxW orgy upon "ameters shown. and is for to incOvId al hullcIN component not 0 Miss system. Before rso, the txdltYng designer mint verify tho apoicabllly of design IxaOmetem and proporly htcorpa0le Ihlt design Into the oveldl truss orgy. AddllkxO temporary aW pennanonl bracingbtAclingdesign. 130ctng Irdlcoled Is to Ixovenl buckling of IMMdrxd web and/ol chord members is alwcrys iequkod lei slafAlty and to prevent colla xe wllh pwssflzile porwr>m hAay rnW Ixoperly damage. For general gtddmce regading the IcdxlcoliDa storage, dollvery, eiecllon and bochig of frusses and Inns systems, RwANSI/FPII ouaBfy Criteria. DSO-89 and BCSI Bulldhp Component MiTek* 6904 Parke East Blvd. Safely Information ovallable hom truss P1010 hulllule. 218 N. Leo Sheet. Sulle 312. Alezandrb. VA 22314. Tampa. FL 33610 russ TrUSS Type Oty Ply 738245 T10660424 738245 V1 Volley 8 1 Job Referenceeo Uonal 7 I I Th Me 16 06.24 50 2017 Pe * 1 AmericanBuildereSupply. Winter Haven. Florida 33880 7 640 s Apr 19 2016 M ek rMusares. nc u r B ID: r??OCSOkwZVhwYIOSTM4_yznGrl•ddnjX4NLuhXGNMGBMJII NmiD1E5T4msmW ORCg4zaSCB 4• 8.14 9.5.13 4$ 14 4.8.14 Scale = 1.17.6 40 = e o 4 20 G 2x4 11 20 10 a-5.3 LOADING ( psi) SPACING- 2-0-0 CSI. DEFL. In Qoc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) rVa rVa 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.15 Vert(TL) We rVa 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 3 n/a rVa BCDL 10.0 Code FBC2014/rP12007 Matrix) Weight: 29 lb FT = 20°L LUMBER- BRACING - TOP CHORD 20 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 20 SP No.3 REACTIONS. ( lb/size) 1=130/9-4-10, 3=130/9.4-10, 4=331/9.4-10 Max Harz 1=-32(LC 13) Max Uplift 1 =-47(LC 12), 3=-53(LC 13). 4=-55(LC 12) Max Grav1=133(LC 23), 3=133(LC 24), 4=331(LC 1) FORCES. ( lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; Cat. II; Exp B; Encl., GCpi=0.18; MW FRS (envelope) gable end zone and C-C Extedor(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL= 1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0.0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) o1 truss to bearing plate capable of withstanding 47lb uplift at joint 1, 53 lb uplift at joint 3 and 55 lb uplift at joint 4. 7)' Semi-ngid pitchbreaks Including heels' Member end fixity model was used in the analysis and design of this truss. Q WARNING. Vanity design parameters and REAO NOTES ON 7711E ANO WCLUOEO M7rEK REFERANCE PAGE MLL7473 rev. rOD3wt5 BEFORE USE. Desl( p1 valid lot use only vAth Mllek® conneclas. n* desIgn is based orgy upon paameters showrx and Is for an hdlvkAxb bolding component. not a htas system. Before tze, the tx/Icing designer mtal verify the aWicablily, of design Ixaanelets and Ixopery Incaporato this deslgn Into the overall I" cling design Bracing Inadicaled Is to Ixevent Ixrclding of kxdlvldual Inns wob and/or chord members orgy. Addllonal temporary and perrnamnl bracalg M iTek_ Is always required for stability and to lxevent tousle vAlh possible personal hltsy and ixoperty damage. For general guidance regardng the labrIcollm storage, dolivosy. erection and bracing of trusses and Innss systems seeANSI/IPI I Quality Crllorto, DSB-89 and SCSI Building Component 6904 Pork* East Blvd. solely Womrallon ovaltable Dom buss Rate Irsillulo. 218 N. Lee Street, Suite 312, Alexandria. VA 22314. Tempo. FL 33610 Job Truss Truss Type oty Ply 73a245 710660425 73e245 V2 Volley 6 1 I Job Reference(optional) American Builders Supply, winter htoven. Frarrao 33960 , wv o np, , e 20,6 ,... e., ,...,.>,.......... ..,v ..W..,. ID:r??OCSOkwZVhwYIOBTM4_yznGrl•5pL51ONz1 16?WrNwOAGw POLeOapDVvl2AICXZaScA 2.8.14 5.5.13 2-8-14 2.8.14 20 2x4 11 40 = 20 Scale = 1:10.5 Tsq LOADING (psi) SPACING- 2-0-0 CS1. DEFL. in poc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Ven(LL) n1a n1a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.23 Ven(TL) n1a Na 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 3 rVa n/a BCDL 10.0 Code FBC2014/TP12007 Mainx) Weight: 15lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5.5-13 oc puffins. BOT CHORD 20 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 1=72/5.4.10, 3=72/5.4-10, 4=150/5-4.10 Max Horz1= 16(LC 13) Max Uphill=-28(LC 12), 3= 31(LC 13). 4=-18(LC 12) Max Gravl=280(LC 29), 3=280(LC 31), 4=326(LC 30) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=140mph (3-second gust) Vasd=108mph; TCDL=4.2psf; BCDL=6.Opsf; h=151t; Cat. II; Exp B; Encl., GCpl=0.18; MW FRS (envelope) gable end zone and C-C Exterior(2) zone;C-C for members and forces 8 MW FRS for reactions shown; Lumber DOL=1.60 plate gnp DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.0psl on the bottom chord in all areas where a rectangle 3.6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28lb uplift at joint 1, 31 lb uplift at joint 3 and 18 lb uplift at joint 4. 7) This truss has been designed for a moving concentrated load of 250.01b live located at all mid panels and at all panel points along the Bottom Chord, nonconcurrent with any other five loads. 8) 'Semi -rigid pitchbreaks Including heels' Member end fixity model was used in the analysis and design of this truss. WARNWO • Vonfly dadpn panamoters and READ NOTES ON 7NdS AND WCLUDED MrrEK REFERANCE PAGE 01,11167,1173 rev. IQ93101S BEFORE US& Design valid to use orgy vAth Mnek® connectors. Ms design is based orgy upon paiameters shown, and Is to an Individual tAdldhtg component. not a pus syslem. Before use, the IAAdh o deslgnei must verify the apptlicatAlly of design parameters and properly hncotpoialo Ot6 design Into the overall building design. ®acing Indicated Is to revenl [)tickling of Individual Inns web and/or chord manners only. Addlllonal tompoiary and permanent bracing M iTek' is always requited Iar stalAlry, and to prevent collapse vAlh possUe personal ",Fly and property danoge. To; general Guidance tegadng the Ic"Icallon, storage. delivery, erection and txochng of trusses and Inns systems. seeANSI/IPI I Quality CAtodo. DSB-09 and SCSI f luBChng Component 6904 Parke East Blvd. Safety Information available from pus Rate Institute, 218 N. Lee Street. Suite 312, Alexandria. VA 22314. Ten". FL 33610 Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets ore indicated. Dimensions ore in ff-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-'hdr For 4 x 2 orientation, locate plates 0-149' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings Ono (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPII : National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths Drawings not to scale) 1 2 3 TOP CHORDS JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSUTPI 1 section 6.3 These truss designs rely on lumber values established by others. 2012 MiTek® All Rights Reserved M!Tek e MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-brocing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design boding shown and never stock materials on Inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor. property owner and oil other Interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment In accord with ANSI/TPI 1. 8. Unless otherwise noted. moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, at green lumber. 10. Comber is a non-structurol consideration and is the responsibility of truss fabricator. General practice Is to comber for dead load deflection. 11. Plate type, size. orientation and location dimensions Indicated ore minimum plating requirements. 12. Lumber used Shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purllns provided at spacing Indicated on design. 14. Bottom chords require lateral bracing at 10 tt. spacing, or less. If no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of on engineer. 17. Install and rood vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. THIS INSTRUMENT PREPARED BY: Name: J.M. Hillery Address: 815 S. French Ave. Sanford, FL 32771 NOTICE OF COMMENCEMENT State of Florida County of Seminole/ /- Permit Number: 1 / 7 6 Parcel ID Number: t..111 0, u e 1111111111111111111 GRANT L OUNTYCLERK, OFCI IRCUITCOURT NOLE C& COMPTROLLER BK, 8835 Ps 1124 (1P9s) CLERK' S 0 2017031340 RECORDED 03/30/2017 08:47:18 AM RECORDINGFEES $10.00 RECORDED BY tsmith 5- 19-30--5,4(p— 100 t- 0040 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) GENERAL constructing DESCRIPTION new 1 story Unit Apartment Complex . %%I c; vo rY P P p..iL.— OWNER INFORMATION: Name: Coastline Address: 815 S. French Ave. Sanford, FL 32771 vo-Q Fee Simple Title Holder (if other than owner) Name: V CONTRACTOR: • Name. RLH Construction f. Address: PO Box 0625 Sanford, FL 32772 Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: Address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as Provided in Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Commencement (The expiration date Is 1 year from date of recording unless a different date Is specified) WARNING TO OWNER,• ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. RT. Hillery gnalure owner's Printed Name Florida Statute 713.13(1)(9):' The owner must sign the notice or commencement and no one else may be permitted to sign in his or her stead' State of';tCr f (6, County of &L,i n01 e , The foregoing Instrument was acknowledged before me this 2-q day of iCL" 20 1 11 Qc> byh1g- 41 YW9%A'% 1 t'lN Who Is personally known to me Name of person making statement ) 1 ( ORwhohasproducedIdentificationIAtypeofidentificationproduced:f u y u tit— Frances M. Rivera -Reyes Notary Public State of Florida My Commission Expires 11127/2020 kin f,f; rniri`i pt, t4_1(& Notary Signalfte Nov 03 17 04:55p Catapano Plumbing Inc 4077307008 p.1 CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: -. q 10 Documented Construction Value: S 72, &6&Uyo Job Address: W • Historic District: Yes No Parcel ID: Residential DCommercial Type of Work: New Addddition ID Alteration Repair Demo Change of Use Move Description of Work: !-A 1,31"to 'Ut. L /% V,&,, r /.14ozeL_ ,/3, t%'w fir' Plan Review Contact Person: Phone: —% Dyy Fax: "le 7-- % "%mo' Email: < Property Owner Information Name . I "11S /t. " Phone: Street: City, State Zip: Title: s" Resident of property? : Contractor Information Name 1 U %"\ ip Phone: V ` J' - Coo Street: • ko • \ •gypp cb ` Fax: '`, • 0' 1 oCi(:( City, State Zip:U-AC [9 L c t Ska State License No.: Architect/ Engineer Information Name: Phone: Street: Fax: City, St, Zip: Bonding Company: Address: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT vIAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COX, MENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, beaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date or application and the code in effect as of that date: 51' Edition (2014) Florida Building Code Revised: June 30. 2C 15 Permt Application 1 Nov 0317 04:55p Catapano Plumbing Inc 4077307008 p.2 TICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. s, Signature of 0•xnerfAgent Date Print Owner,Agent's Name Signature oPNotar)- State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID Signature of /ntractor/Age Date Print Contr r tb Name i ture o otary•State of Florida Date IVE TE MOSQUERA W COMMISSION 0 00138110 D1ARE3:0atober2,2021 Produced ID Ty of rD BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas[] Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Alin. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads Fire Alarm Permit: Yes No APPROVALS: ZONING: UTILITIES: ENGINEERING: COMMENTS: FIRE: WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application Nov 0317 04:56p Catapano Plumbing Inc CATAPANO PLUMBING INC P O BOX 678521 ORLANDO FL 32867 407-730-7000 FAX 407-730-7008 t y antcatacanoDbellsouth.not Anthony Mobile 407-947-4772 4— ,f PROPOSAL, Proposal Submitted To: Worts Performed At 4077307008 p.3 ce.e Icl•l l W.SM 1 Stow eMl M69-• Pbmttlny Meelc•l G•• au. uunu.. N•tw,M •e0 V O•• uN Xtl* • Date: 10/27t2017 Sheet No: Name: RLH Construction Project: Maple Project 1 16 Unit A t $Id Address: Location: 610 W. SPn Street Date of Plans: 2J14/17 Phone: Architect: WDS Design We hereby propose to famish the materials and perform the labor necessary forthe completion of Plumbing as follows: PVC/CPVC 5' out waste and water' standard residential fixtures: 32 toilets, 32 lays, 32 tubs, 16 water beaters, 16 washer boxes, 16 kitchen sinks, & 6 hose bibs 16) A/C chases NO sewers, water services, grease traps, condensates, gas, or concrete work All material is guaranteed to be as specified, and the above work to be performed ut accorterce with the dra specifications submitted for above work and completed in a substantial workmanlike manner for the sum of. s***********•*+si*r****+*++*******.********** Dollars $72,000.00 Any alterations or deviation from the above specifications involving extra costs will be --cocuted only upon written order, and will become an extra charge over and above estimate. All agreements contingent upon strikes, accidents, or delays beyond our control. RESPECTFULLY SUBM]= Catapano Plwnbing, Inc. Notc: this propeaol may W withdrawn byus irra accepted within 10 days Acceptance of Proposal The above prices, specifications and conditions are satisfactory and are hereby accepted. You arree authorized to do the work as specified. . /' i Date. l 3 7 Signature: s C'ryQza,oPl v t6ru °l FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Application Number . . . . . 17-00000876 Date 11/06/17 Application pin number . . . 576468 Revision number . . . . . . . 2 Property Address . . . . . . 610 W 9TH ST Parcel Number . . . . . . . . 25.19.30.512-1009-0080 Application type description NEW 5 & MORE FAMILY BUILDINGS Subdivision Name . . . . . . Property Zoning . . . . . . . GENERAL COMMERCIAL Application valuation . . . . 1497100 Application desc NEW 16 UNIT APARTMENT COMPLEX Owner Contractor COASTLINE apartments llc RLH CONSTRUCTION 815 S FRENCH AVE PO BOX 625 SANFORD FL 32771 SANFORD FL 32772 407) 322-0126 (407) 330-7104 Structure Information 000 000 NEW 16 Construction Type . . . . . VB Occupancy Type . . . . . . RESIDENTIAL USE GROUP Flood Zone . . . . . . . . NONE Other struct info . . . . . FIRE ALARM 1 PLUMBING FIXTURES 25.00 NUMBER OF STORIES 1.00 FIRE SPRINKLER SYSTEM 1 SQUARE FOOTAGE 14052.00 NUMBER OF UNITS 16.00 Permit . . . . . . PLUMBING PERMIT - COMMERCIAL Additional desc . . Phone Access Code 1011253 Permit pin number 1011253 Permit Fee . . . . 912.00 Issue Date . . . . 11/06/17 Valuation . . . . 72000 Expiration Date . . 5/05/18 Qty Unit Charge Per Extension 150.00 6.0000 EA FIXTURES,WATERHEATR,DRAIN,TRAP 900.00 1.00 6.0000 EA SEWER 6.00 1.00 6.0000 EA WATER PIPING 6.00 Special Notes and Comments All projects within the City shall use WastePro for debris removal. Please contact WastePro at 407.774.0800. Normal hours for inspections are from 7:30 through 4:30 Monday through Thursday. Please be aware you must contact the Building Official to schedule a Friday or after hours inspection. This is required since not every inspector is licensed to do every type inspection. Communication is the key, so please contact the Building Official if you have any questions at 407.688.5058 or at dave.aldrichosanfordfl.gov April 6, 2017 1:37:48 PM blaker. Water impact fee $12758.50 Sewer impact fee $28737.50 Other Fees . . . . . . . . . 01-APPLCTN FEE -BUILDING 25.00 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. I _r 1 1, 1, J I-) FIRE INSPECTIONS CITY OF SANFORD 407.562.2786 BUILDING & FIRE PREVENTION BUILDING INSPECTIONS 300 N PARK AVE 855.541.2112 SANFORD FL 32771 DRIVEWAYS -SIDEWALK 407.688.5080 Page 2 Application Number . . . . . 17-00000876 Date 11/06/17 Application pin number . . . 576468 Revision number . . . . . . . 2 Other Fees . . . . . . . . . 01-APPLCTN FEE -PLUMBING 25.00 01-BLDG PLAN REVIEW 4491.00 01-EARLY START AUTHORIZED 250.00 01-FIRE INSPECT -NEW CONST 640.00 01-FIRE IMP-RS 7-2017 3365.16 01-LIBRARY IMPACT FEE 648.00 01-PARKS IMP-RS SINGLE 13035.48 01-POLICE IMP-RS 07-2017 4498.80 01-SEM CNTY RD IMPACT FEE 4140.00 01-SCHOOL IMPACT FEE 24340.00 WD IMPACT:COMMERCIAL 12758.50 SD IMPACT:COMMERCIAL 28737.50 01-BLDG DCA SURCHARGE 1513.32 01-BLDG DBPR SURCHARGE 2270.36 Fee summary Charged Paid Credited Due Permit Fee Total 912.00 00 .00 912.00 Other Fee Total 100738.12 100689.94 .00 48.18 Grand Total 101650.12 100689.94 .00 960.18 Oper: ANTONINIL Type: OC Drawer: 1 Date: 11/07/17 01 Receipt no: 20185 20 619 W 99TH ST 876 SANFORD, FL 32771 BP BUILDING PERMIT RECEIPTS S%0.18 CC CREDIT CARD $960.18 Total tendered $969.18 total payment s960.18 FAILURE TO COMPLY WITH MECHANIC'S LEIN LAW CAN RESULT IN THE PROPERTY OWNER PAYING TWICE FOR BUILDING IMPROVEMENTS. Trans date: 11/07/17 Time: 14:51:09 NOTE: ALL FEES MUST BE PAID PRIOR TO C.O. BEING ISSUED. NOTE: PLEASE BE ADVISED ALL PERMITS MUST BE INSPECTED. City of Sanford Building Division P.O. Box 1788 Sanford, Florida 32771 Phone: 407.688.5150 Fax: 407.688.5152 PLAN REVIEW COMMENT 0 Ad bpi s Date: April 13, 2017 Project: Apartment Building Contact Person: Bob Horian Job Address: 610 W. 9'h Street Contact Phone Number: Application Number: 17-876 Contact E-mail: bob@suncorproperties.com Contact Fax Number: ARCHITECTURAL 1. No UL rating for party walls page 7 detail 2. 2. No UL details for penetrating tenant walls if applicable, ductwork, piping, electrical etc. 3. Cannot locate detail for typical framing of interior walls or type of material, wood, metal stud etc. 4. Sheet 1. Wall details appear not to be for this job. Wood walls with anchor bolts, thickened slab at garage. No garage. STRUCTURAL 1. See above. MECHANICAL 1. Cannot locate an exhaust duct plan for bathrooms. Will require exhausting to outside of building. 2. No details for HVAC drain pan and condensation drain detail. PLUMBING 1. Most apartment buildings I have reviewed have one main plumbing system. Other departments may have some comments on this when they review your plans. ELECTRICAL 1., Proposed Building will require a Main Distribution Center. See NEC section 230.71. Section 230.72 requires grouping of disconnects. 2. Riser Diagram to show Main Distribution Center, Subpanel feeds. 3. Electrical Plan to provide electrical load calculations for sizing Main Service. 3. Plans to contain Unit panel legend indicating all circuits, panel manufacturer, voltage rating, circuit breaker sizes and total load on panel. 4. Cannot locate location of unit panel on plans. Advise. 5. Section R314 ( Residential Code ) requires smoke detectors to be outside each separate sleeping area in the immediate vicinity of the bedrooms. Not indicated on plans. 5. No emergency lighting for corridors on plans. 6. Submit two complete sets of plans addressing all above items. Please direct any questions you may have to Joy Deen at 407.688.5064 or fax to 407.688.5152. You may also contact me by e-mail at joy.deen@sanfordfl.gov. Respectfully, Joy Deen, Plans Examiner ARTICLE 230 — SERVICES 230.82 230.72 Grouping of Disconnects. A) General. The two to six disconnects as permitted in 230.71 shall be grouped. Each disconnect shall be marked to indicate the load served. Exception: One of the two to six service disconnecting means permitted in 230.71, where used only for a water pump also intended to provide fire protection, shall be per- mitted to be located remote from the other disconnecting means. r rvmnto,in .----__a_._ %i,"ni.rhn. r.- . e7'3 itittC_Piia en! g g;ne_ in._n.,_e t no.c. t2 la''8tto'tw B) Additional Service Disconnecting Means. The one or more additional service disconnecting means for fire pumps, emergency systems, legally required standby, or op- tional standby services permitted by 230.2 shall be installed remote from the one to six service disconnecting means for nKmal service to minimize the possibility of simultaneous interruption of supply. ' C) Access to Occupants. In a multiple -occupancy build- ing, each occupant shall have access to the occupant's ser- vice disconnecting means. Exception: In a multiple -occupancy building where elec- tric service and electrical maintenance are provided by the building management and where these are under continu- ous building management supervision, the service discon- necting means supplying more than one occupancy shall be permitted to be accessible to authorized management per- sonnel only. 230.74 Simultaneous Opening of Poles. Each service dis- connect shall simultaneously disconnect all- ungrounded service conductors that it controls from the premises wiring system. 230.75 Disconnection of Grounded Conductor. Where the service disconnecting means does not disconnect the grounded conductor from the premises wiring, other means shall be provided for this purpose in the service equipment. A terminal or bus to which all grounded conductors can be attached by means of pressure connectors shall be permit- ted for this purpose. In a multisection switchboard, discon- nects for the grounded conductor shall be permitted to be in any section of the switchboard, provided any such switch- board section is marked. 230.76 Manually or Power Operable. The service dis- connecting means for ungrounded service conductors shall consist of one of the following: 1) A manually operable switch or circuit breaker equipped with a handle or other suitable operating means 2) A power -operated switch or circuit breaker, provided the switch or circuit breaker can be opened by hand in the event of a power supply failure 230.77 Indicating. The service disconnecting means shall plainly indicate whether it is in the open'.OW or closed ; on , position. 230.79 Rating of Service Disconnecting Means. The ser- vice disconnecting means shall have a rating not less than the calculated load to be carried, determined in accordance with Part III, IV, or V of Article 220, as applicable. In no case shall the rating be lower than specified in 230.79(A), B), (C), or (D). A) One -Circuit Installations. For installations to supply only limited loads of a single branch circuit, the service disconnecting means shall have a rating of not less than 15 amperes. B) Two -Circuit Installations. For installations consisting of not more than two 2-wire branch circuits, the service disconnecting means shall have a rating of not less than 30 amperes. C) One -Family Dwellings. For a one -family dwelling, the service disconnecting means shall have a rating of not less than 100 amperes, 3-wire. D) All Others. For all other installations, the service dis- connecting means shall have a rating of not less than 60 amperes. 230.80 Combined Rating of Disconnects. Where the ser- vice disconnecting means consists of more than one switch or circuit breaker, as permitted by 230.71, the combined ratings of all the switches or circuit breakers used shall not be less than the rating required by 230.79. 230.81 Connection to Terminals. The service conductors shall be connected to the service disconnecting means by pressure connectors, clamps, or other approved means. Connections that depend on solder shall not be used. 230.82 Equipment Connected to the Supply Side of Ser- vice Disconnect. Only the following equipment shall be permitted to be connected to the supply side of the service disconnecting means: 1) Cable limiters or other current -limiting devices. 2) Meters and meter sockets nominally rated not in excess of 600 volts, provided all metal housings and service enclosures are grounded in accordance with Part VII and bonded in accordance with Part V of Article 250. 3) Meter disconnect switches nominally rated not in ex- cess of 600 volts that have a short-circuit current rating 2011 Edition NATIONAL ELECTRICAL CODE 7"5 ELECTRICAL 3. No electrical load calculations for sizing main service. 2. Sheet 3. Electrical table indicates panel location in garage. There are no garages on the plans. 3. Sheet 3. Inner unit, end unit details. No walls shown in details. 4. Sheet 3. Electrical panels indicate AC compressor wattage higher than Air Handler Units. Advise. 5. Sheet 3. Main Service. No conduit or wire sizes from main service to meters. If this a meter center then provide manufactures specifications. 6. Sheet 3. Electrical Panel indicates main lug only. This will not work without a main disconnect at meter location. 7. Sheet 3. Conflicting diagrams feeds from meter to units. 8. Sheet 3. Indicates 1/0 Al THW feed from meter to unit. Appears not large enough for panel feed of 143.60 amps. See table 310.15 (B) (7). 9. Submit two complete sets of revised plans addressing all above comments. Please direct any questions you may have to Joy Deen at 407.688.5064 or fax to 407.688.5152. You may also contact me by e-mail at joy.deen@sanfordfl.gov. Respectfully, Joy Deen, Plans Examiner City of Sanford Building Division P.O. Box 1788 Sanford, Florida 32771 Phone: 407.688.5150 Fax: 407.688.5152 PLAN REVIEW COMMENT Date: June 21, 2017 Project: Apartment Building Contact Person: Bob Horian Job Address: 610 W. 91h Street Contact Phone Number: Application Number: 17-876 Contact E-mail: bob@suncorproperties.com Contact Fax Number: ARCHITECTURAL 1. Sheet 2. Blurred, cannot read. STRUCTURAL 1. No comment. MECHANICAL —/ t x( 1. Cannot locate any supply duct plans. 1 did not Foinment on this on the original plan review. PLUMBING 1. No comment. Deen, Joy From: Sent: To: Subject: Attachments: Joy Deen City of Sanford Plans Examiner PH: 407.688.5064 Fax: 407.688.5152 Deen, Joy Monday, April 17, 2017 10:03 AM bob@suncorproperties.com' 17-876 17-876.pdf eC Deen,Joy From: Sent: To: Subject: Attachments: Joy Deen City of Sanford Plans Examiner PH: 407.688.5064 Fax: 407.688.5152 Deen, Joy Wednesday, June 21, 2017 10:43 AM bob@suncorproperties.com' 17-876B 17-876B.pdf Deen, Jo From: Deen, Joy Sent: Wednesday, August 02, 2017 10:22 AM To: 'bob@suncorproperties.com' Subject: 610 W. 9th Street permit number 17-876 I sent you a plan review comment letter on June 21, 2017 and have not heard back from you. Please bring me up to date. 17al, /-IJ Cf l 1 W.D.S. Design group 2612 Herbison dr Orlando, FI 32810 JULY 27, 2017 City of Sanford Ref: Maple Project 9tn Street Project Application No. 17-876 Project Corrections 1.) PLEASE SEE SHEET 3 BOTTOM OF PAGE FOR CALCULATIONS 2.) PLEASE SEE ELECTRICAL LAYOUT, IN HALLWAY E.P. IS INDICATED WHERE THE ELECTRICAL PANEL IS LOCATED 3.) PLEASE SEE DETAIL PAGE FOR TYPICAL FRAME WALL DETAIL. 4.) PLEASE SEE ELECTRICAL CALCULATIONS ON BOTTOM OF ELECTRICAL PAGE S.) PLEASE SEE -ELECTRICAL RISER -DIAGRAM -ON THE ELECTRICAL PAGE 6.) PLEASE SEE GANG BOX DETAIL FOR THE MAIN. SHUT OFF ON THE ELECTRICAL PAGE. 7.) PLEASE SEE ELECTRICAL RISER DIAGRAM, BOTH INDICATE A 2/0 WIRE SIZE 8.) PLEASE SEE NOTES AT THE GANG BOX DETAIL AND ALSO NOTES ON THE ELECTRICAL RISER DIAGRAM Steven A THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY SA. t ENH e p n e rHEPNERUSINGADIGITALSIGNATUREE. EPNERPRINTED COPIES OF THIS DOCUMENT = ARE NOT CONSIDERED SIGNED AND AR0106 SEALEDANDTHESIGNATUREMUSTBEsyL RespectfullyVERIFIEDONANYELECTRONICCOPIESSteven Hepner—04'00' form works architecture p o box 540344 orlando, fl 407.4 .1 9 • C City of Sanford Engineering And Planning Department O ' IAPPROVALNOTICE1877-11 To: Larry Poliner — RCE Consultants, LLC Email: rceconsultants@cfl.rr.com From: Michael T. Cash, Planning Engineer City of Sanford Planning and Development Services Date: October 5, 2015 You should receive 1 page(s) including this cover sheet Subject: Approved ENGINEERING PLANS for: Maple Avenue Apartments On October 5, 2015, the Development Review Team approved the ENGINEERING PLANS for MAPLE AVENUE APARTMENTS, received October 5, 2015 located at 610 W. 91h Street. Approval of these plans is subject to specific conformance with the City of Sanford's Land Development Regulations and any special conditions approved by the City Commission as may be outlined below. It is the responsibility of the developer to correct any deficiencies with the plans as constructed which result in a failure to comply with all applicable City, State and Federal regulations. Approval of these plans does not constitute a waiver of any code requirements nor does it relieve the developer of the responsibility to meet those requirements. This approval is subject to the following stipulations: 1. All construction must meet all City of Sanford Codes and Land Development Regulations. 2. All other permits required for this project must be obtained. An EPA Notice of Intent (NOI) for Stormwater Discharge Associated with Industrial Activity Under an NPDES Permit must be filed with EPA for all sites which are one (1) acre and greater. 3. As-builts and Certificate of Completion from the engineer of record as specified at the Pre - Construction meeting to be submitted to the City prior to C.O. 4. All easements and right of way dedications, if any, must be conveyed to the City prior to Site Development Permit issuance. 5. The developer shall provide landscaping adjacent to the dumpster enclosure. Coordinate with Sabreena Colbert for planting specifics. Prior to the issuance of a Site Development Permit, a completed Site Development permit application and a contractor's or engineer's certified cost estimate shall be submitted for review and approval. In addition, a pre -construction conference is required and will be scheduled by this office no earlier than 72 hours after receipt of the Site Development permit application and cost estimate. The Site Development permit and approved plans will be released at the pre -construction meeting upon receipt of the permit fee. Building Department Permits may not be released prior to the issuance of the Site Development Permit. This approval is good for a period of one year. A Site Development Permit must be obtained and construction started within that time period or this approval will expire. If you have any further questions, you may contact my office at (407) 688-5148. T:\Development Review\06-Post Approval-PreCon\Approvals\2015\Maple Avenue Apartments - 610 W 9th Street.apr.2015.docx