Loading...
HomeMy WebLinkAbout341 Specialty Pt 17-916 New addition10"x12" RA DUCT BENEATH SA DUCI 1 O"xl O"SA DUCT ABOVE RA DUCT 10" OUTSID9 AIR 400 CFM WITH,;NEYWELL ARD10TZ.10" TERMINATE IN WALL 61:3. 1" PUMPED CONDENSATE 'DOWN ALO G EXTERIOR WALL. TER INATE 2" ABOVE CONCRETE ��PLASH BLOCK. PERMIT #--Z-Z--- ,REviEWED FOR c - ompl-IANCF- pip, EXAMINER ,'DATE ;\)xLDING s At4r- opto ,o,,, & R _O \Z co cO Q3V113 v � s � -v:N cl) mlu z 0 cn r-- uJ UJ STEEL JOIST 3/8" ALL THREAD ROD — CONNECTED TO STRUCTURE ABOVE " ALL THREAD 10 GA. STEEL REPLACABLE FILTER WIRE HANGER REF. PIP(N DISCONNECT OR CIRCUIT BREAKER Tj- b FAN z su�M DUCT OWI rip 2" x 2" KENDOR BOLTED USING 37' ALL THREAD FLOAT SWITCH AUXILLARY DRAIN PAN CONDENSATE DRAIN AND P—TRAP HORIZONTAL AIR HANDLING UNIT MOUNTING DETAIL NOT TO SCALE A/C UNIT MAXIMUM SAG 1/27 PER FOOT OF SUPPORT SPACING FLEX DUCT DRAIN CONNECTION (3/4" MINIMUM) CLEANOUT WITH THREADED PIPE CAP CONDENSATE TRAP DETAIL N.T.S. CMD—m BRANCH DUCT — W MANUAL DAMPER WITH QUADRANT LOCKING LEVER L : 1/4 W;(4 MIN_) SUPPLY DUCT AIR FLOW RETURN DUCT AIR FLOW TRUNK LINE BRANCH DUCT TAKEOFF DETAIL N.T.S. 45DEGTAP METAL OR FABRIC STRAP 20 MINIMUM NOTES: 1). DUCT SHOULD EXTEND STRAIGHT FOR SEVERAL INCHES FROM A CONNECTION BEFORE BENDING. 2). SUPPORT SYSTEM MUST NOT DAMAGE DUCT OR CAUSE OUT —OF —ROUND SHAPE. 3). DUCTS SHALL BE PER THE FBC MECHANICAL 2010 AND UL 181 RATED. FLEXIBLE DUCTWORK SUPPORT DETAIL I4I3T TO SCALE SEE DUCTWORK AND ACCESSORIES NOTES FOR SPECIFICATION OF DUCT MATERIALS. FASTENING SYSTEM. AND SEALING METHODS .......LNG TYPICAL CHANNEL STRAP AND SADDLE AND STRAP DUCT HANGING DETAIL HANGING DETAIL NOTE: ALL STRAP SHALL BEE A MINIMUM OF 1-1/2,26 GA GALVANIZED STEM WITH A 6 FT MAXIMUM SPACING. METHODS OF HANGING RIGID FIGERGLASS DUCTS N.T.S. HMCDUCT—FG ALTERNATE FOR LOW CLEARANCE N.T.S. CEILING TILE SUSPENDED T-BAR CEILING GRID NOTE: 1. ALL REFRIGERANT PIPE AND INSULATION SHALL BE INSTALLED SECTION BY SECTION AT THE SAME TIME AND IN CONJUNCTION WITH THE INSTALLATION OF THE PVC REFRIGERANT PIPE CHASE. 2. ALL REFRIGERANT PIPING INSTALLED IN THE PVC CHASE SHALL BE CAPPED AND PRESSURE TESTED ACCORDING TO SPECIFICATIONS PRIOR TO INSTALLATION OF CONCRETE SLAB. 3. ANCHOR CONDENSING UNIT TO CONCRETE SLAB AS FOLLOWS. PROVIDE ONE 1-1/2" 16 GA GALV. STEEL. STRAP AT EACH CORNER. SECURE STRAP TO UNIT WITH WITH (2) 3/4-f lO SHEETMETAL SCREWS. SECURE STRAP TO CONCRETE SLAB WITH 1/4"DIA X 2-3/4" RED HEADS. CONDENSING UNIT (TO BE INSTALLED ON 1" THICK NEOPRENE ISOLATION PATS) FLEXIBLE SEAL TIGHT ATTACHED TO ELEC— TRICAL CONDUIT ELECTRICAL CONDUIT FOR LOIN VOLTAGE CONTROL WIRING GRADE PIPE CHAf2T a,cnom PIPE SIZE PVC REFRMERAW PIPE CHASE S12E slir TD 1-S 4 1-7 TO 2 Ir 3-1 TO 4-1 8' SEE NOTE #3 llY R �­. a r .r w HARD -DRAWN COPPER. PVC REFRIGERANT PIPE CHASE.CUT OFF V ABOVE GRADE AND SEAL W/FOAM FILL INSULATION CONDENSING UNIT PIPING DETAIL ICES. CU—PC2 HANGER MIRE OR STRAP 5'-d' MAX DISTANCE BETWEEN SUPPORTS MAX. SAG 1/2' PER FOOT OF SUPPORT SPACING. SPIN -IN W// MANUAL DA(�IPER 1-1 GAIV.STEEL BAND RIGID AIR DUCT_ CLAMPTO MATCH DUCT SEE "METHODS OF DIAMETER HANGING DUCTS' FOR REQUIREMENTS INSULATED I FLEXIBLE DUCT UL-181 CLASS 1 . AIR DIS^F1UST3t FIN.CIUNG INSTALL STEEL DUCT NOTE CLAMPS ON BOTH INNER AND OUTER JACKETS. SEAL INNER JACKET AIR -- ALL STRAP SHALL BE A TIGHT WITH MASTIC. NYLON ORAW8ANDS MINIMUM OF 1-1/2% 26 MAY BE USED IN NON PLENUM AREAS. GA. GALVANIZED STEEL HANGER "RE SHALL BE FLEXIBLE DUCT DETAIL A MINIMUM OF 22 GA- N.T.C. F1E)OUCT CONCRETE OR WOOD INSULATED DUCT INSERT DUCT (VARIES) IN WALL t FRAME WAU— CAP SLEEVE AND SEAL JOINT. / USE FOIL DUCT TAPE & MAKE 2 PASSES i WALL CAP 6" SHEET METAL EXTENSION COLLAR 26 GAUGE COLLM SUPPLY AIR GRILLE N.T.S. CD-1 SUPPLY AIR GRILLE r SEAL EXTERIOR & INTERIOR PENETRATIONS W/ WEATHER 'PROOF CAULK ALL AROUND MAINTAIN MINIMUM SAFE AIR TIGHT DISTANCE OF 48" BETWEEN PENETRATIONS TO BE BOTTOM OF WALL CAP AND PREPARED BY BUILDER PRIOR GRADE TO INSTALLATION. WALL DUCT PENETRATION DETAIL :v DING NOT TO SCALE SANFORD 6� -pARIoo- M-2 v s s o_ C�ze� CC) c� N N � CZ o _Ns vSZ 1,J X S � < Rk— S M Z O W Uj F- 4A A a o cf) w cy II OPL4 MU00 �QM� �W,-, U) m • • U) W . . z W C]' W 3"o Z < 3: < w- 0 <t 0 0 OFFICES OFFICE SPACES 1 1 5 380.00 0.06 5 1.90 0.00 32 DAYCARE (SICK ROOM) 3 10 0.18 25 0.00 0.00 0 CLASSROOMS (AGES 5-8) 1 10 0.12 25 0.00 0.00 0 CLASSROOMS (AGE 9 +) 1 1 10=_730.00 0.12 35 25.55 0.00 343 STAGES, STUDIOS (d) 1 10 0.06 70 0.00 0.00 0 TOTAL VENTILATION REQUIRED REQUIRED 409 EXHAUST RATE SCHEDULE PER ASHRAE IAQ 62.1- 2010, TABLE 6A SPACE ROOM'! ID AIR CLASS SQFT OF AREA CFM PER UNIT READ CFM PER SQFT NOT USED NOT USED NOT USED TOTAL EXH CFM PER SPACE TOILET, PUBLIC Rest Room 2 2 42.00 50/70 - - - 0 TOILET, PUBLIC 1 1 2 1 2 1 0.00 50170 - - - 0 WOODWORK SHOP / CLASSROOMS 2 0.5 - - - 0 TOTAL EXHAUST REQUIRED REQUIRED 0 DEC SPLIT SYSTEM HEAT PUMP SCHEDULE SYSTEM 1 SPACE SERVED OFFICE & TRANING MANUF TRANE AHU MODEL TEMM013481-141 DIMENSIONS W x 27" x 22" WEIGHT 170 # 10KW HEATER BAYHTR1510LUGB FUSE/AMP 52/60 HP MODEL 4TWR6048H1000A FUSE / AMP 50 DIMENSIONS 46" x 38" x 35" WEIGHT 271 # ELEC 120/208-1-60 COOLING BTUH 481,000 HEATING BTUH 401800 CFM 1,600 OA 400 SEER 16 EER N/A LINESET 3/8" x 7/6' CONDENSATE 3/4" T-STAT HONEYWELL- THS32OU1000DAG F77TWM- NUMBER 7563672 v s _o N � CZ �v o0 s s s _ C/) M z O W W Ij,j Cn m � W 06 Z F- O Q � 0