Loading...
HomeMy WebLinkAbout717 W 1 St 17-970 Int_ext. remodelCOVER PORCH / / CLG. HGT. ® AS EXISTING CLG. HGT. AS EXISTING BEDROOM#2 FAMIL ]ROOM / O S. D. O S. D. QD CLO. // \ \ CTCLG, HGT. @)AS EXIST] ] ` BA 400M CLG. HGT. ®AS EXISTING DINING ROOM / CLO. OS.D. OS.D. CLG. HGT. ® AS EXISTING, BEDROOM #2 i KITCHEN / Ld / BREAKFA`_ z LL AREA 4 I �� -�\ 60"AFF CLG. HGT. AS EXISTING I � 14'-6" UTILITY IOS.D. OS.D.\ ROOM / \\ EXISTING WALL // UNDECIDED T _l$I_ 2-6 3/4" --- A/C UNIT �/ ROOM I I 0 I Q I I I __-T3'-10" V I 0) I COVER PORCH CLG. HGT. ® AS EXISTING FAMILY ROOM CLG. Hjr� _N 10 SAS RXIaTIVIG EXISTING 3'X5' WINDOW TO REMAIN REF. L KITCHEN BREAKFAS AREA CLG. HgT'%KS X#QG CLG, HGT. ® AS EXI`. BATHROOM o—r) BEDROOM;f2 CLG. HGT. ® AS EXISTING T1-11 INTERIOR SHEATHING TO BE INSTALLED BY V I T1-11 INTERIOR ,---SHEATHING TO BE INSTALLED BY CONTRACTOR Ir � WH I CLG. HGT. ® AS EXISTING EXISTING AHU WALL OPENING RELOCATE TO BE CLOSED AND rI CLG. HGT. ®AS EXISTING 2'-6 3/4" EXISTING AHU REMOVED.HARDI-PLANK ADDED UTILITY DISCONNECTED TO EXTERIOR W/ J"SHEATHING I \ W/DuPont'"'Tyvek DHomeWrop. -8" ROOM \ EXISTING OPENING TO 0 EXISTING WALL UNIT TO BE - BE FRAMED BY 2X REMOVED.OPENING TO BE ��UNDECIDED MEMBERS W/ 1/2° CLOSED UP BY CONTRACTOR ROOM GYP. BOARD BOTH GARAGE SIDES CLG. HGT. ®AS EXISTING GARAGE -*2'-4., EXISTING WOOD SIDING -- T1-11 INTERIOR SHEATHING TO BE REMOVED & NEW LOCATION r TO BE INSTALLED BY HARDI-PLANK TO BE OF AHU + CONTRACTOR ADDED CONTRACTOR TO COVER EXISTING AHUk�_ QEXPOSED SHEATHING t W DuPontT"'T ek®HomeWra 1F1 / YV P EXISTING 2"X4" POST W/ HARDI-PLANK ATTACHED —To'! AREA TO BE WORK ON EXISTING FLOOR / ELECTRICAL PLAN EXISTING GYP. BOARD /� \ FASTEN T BATTEN / \ EXISTING MTS-12--!-- SIMPSON STRONGTIE STRAP ® EA. RAFTER W/ 10D NAILS \ PROPOSED 1/2" GYP. / BOARD ADD R-15 INSULATION :���_ BETWEEN EA. STUDS DETAIL B EXISTING ARCHITECTURAL SHINGLES EXISTING 2"X4" BLOCKING — EXISTING 2"X4" DBL TOP PLATE EXISTING 2"X6"RAFTER PROPOSED HARDI-PLANK (NOT 0418.04.) FASTEN TO DuPont"TYVEK®H TO 3/4' SHEATHING (SEE A1.2 FOR DETAILS) Scale: 1"-1'-0" EXISTING 2"X4" STUD - WALL ® 16" O/C PROPOSED 1/2" GYP. - BOARD EXISTING BASE TRIM - 3/4" SUB FLOORING ( - FINISH TO OWNERS SPECIFICATIONS) / Scale: 1/4"-1'-0" PROPOSED HARDI-PLANK (NC 0418.04.) FASTEN TO DuPont'"TYVEKOI TO 3/4" SHEATHING (SEE A1.2 FOR DETAILS) —ADD R-15 INSULATION BETWEEN EA. STUDS j EXISTING 2"X4" BASE PLATE ' EXISTING 2"X8" CONTINUOUS 1 RIM FASTEN TO 4"X4" POST W/ 16D NAILS EXISTING 2"X8" // EXIST FLOOR JOIST DETAIL A G 4X4 POST EXISTING INSULATION EXISTING 2"X8" FLOOR JOIST EXISTING 16"X16" - CONC. PIER Scale: 1"-1'-0" DEMOLITION PLAN Scale: 1/4"-V-0" DETAIL B - `\ DETAIL 3/4" SUB FLOORING \ ( FINISH TO OWNERS SPECIFICATIONS) d I\ I � EXISTING `A JOIST EXISTING 2"X8" HANGER FLOOR JOIST III -III �_ 7 I= I ! AREA TO BE WORK ON EXISTING ARCHITECTURAL SHINGLES EXISTING MTS-12 SIMPSON STRONGTIE STRAP ® EA. /\ RAFTER W/ 10D NAILS TIMBER BM HGT. — 9-- 5„ Y I ADD R-15 INSULATION BETWEEN EA. STUDS =DE NK (NOA 07- ITYVEK�HO'v1 WF EXISTING 2"X4" STUD WALL 16" O/C EXISTING 2"X4" BASE PLATE NAILED TO J" SUB FLOORING W/ 16D NAILS \� FIN_ FL. LEVE- L 2'-63/4'� `F EXISTING 2"X8" CONTINUOUS / '_ RIM FASTEN TO 4"X4" POST W/ 16D NAILS EXISTING 4" - �T neT n- +7-�EXISTIN I IT I T-T-NG- a JE 5764 NORTH ORANGE BLOSSOM TRAIL # 209, 32810 CONTACT: 407-860-5126 Notes: ELECTRICAL LEGEND DEFINITION NOTES 125V OUTLET 20 AMP SINGLE POLE FSYMBOL ll I1 110V OUTLET 1/2 OF OUTLET 110V OUTLET N1RED TO SWITCH EOUIPED WITH GFl 110V OUTLET GROUND FAULT (TAMP STANT �J &/III\ 220V OUTLET 4 WIRE CONNECTION WP EXTERIOR UL �INTTEERRRUPATFRT GFF1 WATERPROOF OUTLET SWITCH $3 SWITCH 3-WAY OPER. $4 SWITCH 4-WAY OPER. WALL 4 MOTED LIGHUNT y.( ( ) CEILING LIGHT VAPOR %Co VP PROOF IGHT (01 RECESSED CAN �- WALL SCONCE PREWRE 1 CFM PER O VENT. FAN SQ. Fr. VENT. FAN 1 CFM PER W/UGHT SQ. FT. VANITY UGHT FIXTURE BUILDER) (SPEC'S TBO BY 4'X 2-BULB WRAP FLUESCENT AROUND 2' FLUORESCENT 4' FLUORESCENT 4' TRACK UGHT F-----.,�—n� d®d PANEL METER SMOKE BAD. BAD( -LP OO S.D. DETECTOR W/ HARDWIRE S.D. WALL MOUNTED BATL BACK-UP W� HARDWIRE SMOKE DETECTOR BATT. BACK-UP MONOXIDE/ W/ HARDWIRE ®S/COCARBON SMOKE DETECTOR INTER CCO NECATED COMBO DISTANCE 13E OF NOT LESS THEN 4' FROM WALL k�( PENDANT ucHr 4 ATURAL GAS OUTLE e TELEPHONE JACK WATER HEAT. souR IcrlmoN CE TO BF EI FVATED MIN, DISCONNECT Ia' aFF. AIR. COND. A/C DISCONNECT TV.TELEVISION JACK REQUIRED TO O J-BOX BE SUPPORTED IN ACCORDANCE WABSUCHAFORD S INSPECTION CEILING BOX REQUIRED TO CEILING BE SUPPORTED FANLIGHT IN ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION FLOOD LIGHT AHU AHU DISCONNECT REV: DESCRIPTION: HARDI-PLANK ADDED PROPOSED FLOOR/ ELECTRICAL PLAN Q EXISTING WINDOW TO REMAIN SECTION A PROFESSIONAL SEAL: Scale: 1/4"-1'-0" CONSTRUCTION ISSUE `��� C gM E N�9',��i .` No 79154- * ; 1/3/2018 * - �'. STATE OF O R { PO ODE OMPLIANCE TO0NA'?��� ENGINEER: ` TANER S. HAMZAWI TE LICENCE NO. 79154 MOMENT ENGINEERING, INC. CIVIL & STRUCTURAL DESIGN 201 17th Street Suite 3021 S NF RD. UiL C D� Atlanta, 1 30363 APR T ,iS SHA S GO T LED ycynE A Tel #: 561-603-5894 UC r E ;O 0 EED I A T WWORK Aj�JtD NOT CONTRACTOR / OWNER: �JTHr 011 '9T • VI 7$y C Mlj ALj(rR gA T IDEA YOF/TH RQQ01 NS9FT ETi( IC9 WOODRUFF ALLEN C OOR H L IU NCE Qf A ERJvSI RE ENT BU D !G O F IAL F O HF,A AFTE SITE: RE IRIN CDR CT ION �F FRQ INP Ns, 717 WEST 1ST STREET, CONST CTION OR VIOLATIONS 0 THIS C DE SANFORD, FLORIDA �JILDw^ TITLE: FLOOR PLAN SANF'.)%?D SCALE AT AT: DATE: DRAWN: # 1 7- 9 7 D �F�;,;i NOTED 1/3/2017 E.ROILE Scale. 1/2"-1'-0" PROJECT NO: DRAWING NO: A 1.0 BY: DATE: 11/10/17 11/10/17 T.H ION DO LOAD CALCULATIONS ONE FAMILY DWELLING WITH HEAT PUMP (NEC CODE #D2 HOUSE PLAN: 1 0 IMODEL 1337 SQ. FT. GENERAL LIGHTING 3VA. PE13SQ, FT. 4011 2 20AMP APPLIANCE CIRCUITAT 1500 VA EA. 3,000 1 LAUNDRY CIRCUIT AT 1,500 1 RANGE'' AT NAME! PLATE RATING ORCOOKTOP/OVEN 12,000 1 WATER HEATER 4,500 1 DISHWASHER 1,200 1 CLOTHES DRYER 5,000 1 DISPOSAL 500 1 IMICROWAVE 1,500 1 1 REF, 1,200 SUBTOTAL OF GEN ERAL LOAD 34411 FIRST 10 KVA OF GENERAL LOAD AT 100% 10,000 REMAINDER OF GENERAL LOAD AT40% 124411 IVA.X 0.4 1 9764.4 TOTAL NET GENERAL LOAD 19,764 4TON HEAT PUMP #128 AMP X 240 VA 6720 10 KW ELECTRIC HEAT AT 65% 6500 N ET GEN ERAL LOAD 19,764 NET TOTAL H EAT 13220 TOTAL LOAD 32,984 CALCULATED LOAD FOR SERVICE 321 0 VA/ 240 AMP SERVICE REQUIRED V, I 137}AMP NOTE: ALL BREAKERS SERVING HABITABLE RECEPTACLES SHALL BE ARC -FAULT TYPE PER NEC 210-12=REQUIREMENTS. NEUTRAL CALCULATION, LIGHTING, APPLIANCE LAUNDRYLOADS:I 3000 VA @ 100/ REMAINDER @ 35% NET LOAD RANGE: 12,000 @ 70% DRYER: 5, 000 @ 70% ;TOTAL NEUTRAL AMPACITY: 18489/240 78A tt2 AL MIN IMUM N EUTRAL CONDUCTOR. 14,283�VA i 1 6,949 VA 8 400,VA 3, 500j VA 18,849yVA {„ I- - TIMBER BM HGT @ AS EXISTING FIN. FL. LEVEL @ AS EXISTING --�rll-il-Ili MBER BM HGT @ AS EXISTING N. FL. LEVEL @ AS EXISTING 94-M- T- 11-L1- I PROVIDE 3 #1 CU, 1 #6 CU GND 2" CONDUIT OR PROVIDE 3 #2/0 AL, 1 #4 AL GND IN 2" CONDUIT. (CONDUIT TO TERMINATE ABOVE SOFFIT ® OVERHANG.) EXISTING 150 AMP ELECTRICAL RISER COMBINATION SERVICE 150 AMP NOT TO SCALE. DISCONNECT SWITCH AND 120/240 VOLT M ELECTRIC METER IN 1 PHASE GENERAL NOTES: NEMA 3R ENCLOSURE MLO A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY PANEL WITH APPLICABLE PROVISIONS OF THE 2008 NATIONAL ELECTRICAL CODE, LOCAL CODES, AND ALL LOCAL POWER COMPANY 150A/2P REQUIREMENTS. MCB B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS NOTED OTHERWISE. TELEPHONE SERVICE CABLE TELEVISION ENTRANCE EQUIPMENT SERVICE ENTRANCE EQUIPMENT POWER COMPANY TRANSFORMER INTERSYSTEM BONDING GRADE PROVIDE 150 AMP, 120/240 VOLT, 1 PHASE SECONDARY ELECTRICAL SERVICE. PROVIDE 3 #1 COPPER (CU) IN 1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 #2/0 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. TERMINAL AT LOW VOLTAGE CONNECTIONS — 1 #4 CU SERVICE GROUND CONNECTED TO CONCRETE ENCASED FOOTER STEEL PER NEC 2008 250.52(3). 5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD � t _= 11111 T REMAIN �= �PROPOSEDRIGHT ELEVATIO Scale: 1/4"-1'-0" EXISTING WALL UNIT TO BE REMOVED.OPENING TO BE — CLOSED UP BY CONTRACTOR EXISTING AS X ARCHITECTURAL EXISTING SHIN CHIMNEY TIMBER BM HGT AS EXISTING EXISTING EXISTING 2"X4" TIMBER TIMBER FRAME TRIM RAILING AROUND BRICK COLUMN FIN. FL. LEVEL @ AS EXISTING EXISTING ATTIC VENTS EXISTING LATTICE TRIM EXISTING FRONT ELEVATION Scale: 1/4"-1'-0" TIMBER BM HGT 19 AS EXISTING — — TIMBER BM HGT @ AS EXISTING o c ( -- EXPOSED EXPOSE / EXTERIOR SHEATHING EXPOSED J EXTERIOR SHEATHING FIN. FL. LEVEL @ AS EXISTING c c� AHU C �STING REAR VIEW 2 Scale: 1/4"-1'-0" EXISTING LEFT ELEVATION Scale: 1/4"-1'-0" r @ AS EXISTING WHIPS HARD] —PLANK \Dl—PLANK SIDING AHU PROPOSED REAR ELEVATION 6 Scale: 1/4"-1'-0" J E 5764 NORTH ORANGE BLOSSOM TRAIL # 209, 32810 CONTACT: 407-860-5126 Notes: REV: DESCRIPTION: QENCLOSED AREA. HARDI—PLANK ADDED EXISTING WINDOW TO REMAIN QHARDI—PLANK ADDED AND WOODEN SIDING REMOVED PROFESSIONAL SEAL: CONSTRUCTION ISSUE "�00� S.t'HA41'',i �\CENsic:,X "'.' No 79154 * ; 1/3/2018 •, STATE OF ENGINEER: TANER S. HAMZAWI LICENCE NO. 79154 MOMENT ENGINEERING, INC. CIVIL & STRUCTURAL DESIGN 201 17th Street Suite 3021 Atlanta, GA 30363 Tel #: 561-603-5894 CONTRACTOR / OWNER: WOODRUFF ALLEN C SITE: 717 WEST 1ST STREET, SANFORD, FLORIDA TITLE: h SANFOFZD 5.1 2 :PAa�r ELEVATION PLANS SCALE AT Al: NOTED DATE: 1/3/2017 DRAWN: E.ROLLE PROJECT NO: DRAWING NO: A2.0 BY: DATE: 11/10/17 11/10/17 T.H ON OD