HomeMy WebLinkAbout1401 W Seminole Blvd 18-3618 Fire alarme r= U SYMBOL : DESCRIPTION BRAND MODEL sox CODE WIRE TYPE PANELS & ANNUNCIATORS NAC# EXISTING 4009 IDNET NAC EXTENDER PANEL, BEIGE,12Q VAC / W/ 10AH BATTERY SIMPLEX 4009-9201 2081-9274 2FG NOTIFICATION APPLIANCES : . MULTI -CANDELA CHIME/STROBE, WALL MOUNT, RED, FIRE, CLEAR LENS WHEELOCK CH70 24MCW FR 4C 4L V MISCELLANEOUS DEVICES SA EXISTING, SYNC FLASH MODULE CLASS B WHEELOCK DSM-12/24-R " DS i 0KA EXISTING, END -OF -LINE RESISTOR IOK (EOL) SIMPLEX 4081-9008: NR SS ❑P . EXISTING, 120/240V -15A PARALLEL PROTECTOR ; DITEK, DTK-120/240HW-SS NR BA CKBOX CODES CODE I BOX SPECIFICATIONS CODE BOX SPECIFICATIONS 4A 4 SQ. BOX 1112 DEEP 1E SINGLE GANG BOX 21/2 DEEP 4B 4" SQ. BOX 11/2" DEEP W/ COVER _1F I SINGLE GANG BOX 21/2" DEEP W/COVER 4C 4" SQ, BOX 11/2" DEEP W/ 11/2" EXT. RING 1G SINGLE GANG BOX 2 3/4" DEEP 4D 14" SQ. BOX 21/8" DEEP 1H ISINGLE GANG BOX 31/T' DEEP 4E 4" SQ. BOX 21/8" DEEP W/ COVER 2A I DOUBLE GANG BOX 2" DEEP 4F 4" SQ. BOX 21/8" DEEP W/ 1112" EXT. RING 211 1 TWO GANG BOX 21/2" DEEP 4G 4" SQ. BOX 21/8" DEEP W/ SINGLE GANG COVER 2C TWO GANG BOX 2 3/4" DEEP 4H 4"SQ. BOX 21/8" DEEP W/ TWO GANG COVER' 5A 15 GANG BOX 21/2" DEEP 4J 4 SQ. BOX 21/2" DEEP 6A 16 SINGLE GANG BOXES 31/2" DEEP 4K 4" OCT. BOX 11/2" DEEP 6B 16 GANG BOX 4L 4" OCT. BOX 11/2" DEEP W11112" EXT, RING 6C 6 GANG BOX 21/2' DEEP 4M 1411/16" SQ. BOX 21/8" DEEP 6D 16 GANG BOX 31/2" DEEP 4N T411/16" SQ, BOX 11/2" DEEP W/ 1112 EXT. RING FBO I FURNISHED BY OTHERS 4P 1411/16" SQ. BOX 21/8" DEEP W/ 11/2" EXT, RING MFG I SUPPLIED BY MANUFACTURER 4Q 77SQ, BOX 11 22" DEEP W/4098-9832 ADAPTER MDW I MOUNTS TO DUCTWORK 4R 4" SQ. BOX 11/2" DEEP W/RACO 787 OR EQUIV. MBD I MOUNTS IN BOX BEHIND DETECTOR 4S 4" SQ. BOX 11/2" DEEP W/4098-9863 ADAPTER WM ]WALL MOUNT 1A JSINGLE GANG BOX 11/2" DEEP DT DESK TOP MOUNT 1B SINGLE GANG BOX 2" DEEP, DS I REFER TO.PRODUCT DATASHEET 1C TSINGLE GANG BOX 21/8'` DEEP NR INO BACKBOX REQUIRED 1D SINGLE GANG BOX 21/8" DEEP W/COVER I TRM 3.5" WIDE SNAP TRACK W/MOUNTING SCREWS FOR ADDITIONAL BACK BOX OPTIONS, REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND INSTALLATION INSTRUCTIONS, FIPRAE ALARM WIRE LIST ACCEPTABLE CABLE TYPES " n. s Z T Z k o CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES K REMOTE TEST SWITCH/LED (2) 2 COND. STRANDED 14 AWG X X X M IDNET UTP SOLID 18 AWG X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA NOTES 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * '40%. FILL PER N.E.C. 3/4" 0,21 SQ INCH * 1-1/2" 0.82 SQ INCH * SUBSCRIPT "u"; UNSHIELDED CABLES MIXED WITH 1" 0,34 SQ INCH * 2" 1.34 SQ INCH * SHIELDED CABLES OF SAME CIRCUIT DESIGNATION. **OUTDOOR AERIAL CABLE REQUIRES MESSENGER ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED'CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. EN LKAL N TES : ... ::� "A. w. .... a .! .. .. .. ,. ..r �. .-..,.-.':1.r. .-,,,... .....v..-,:,_..: w; �,. ..,w:.,. rhL:• :I�'Pr ..c^A_ et: ..Y. rn. ,:, . -,r.. -. eP s,. .„>,„T . :,,.- -�., .w:L ,. .� ;.. x .. .. ..:- „�• k; ', :.:L ::. '1.. 1;:A: 1.1«.r „x CENTRAL FLORIDA REGIONAL HOSPITAL 4000 NAG Standby! Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 400979201 1. 14009.IDNET NAC EXTENDER, 120 VAC 010850 0.m50 0.1850 ©.1850 Panel Totals 0.0850 0.1850 Notification Appliances Setting CH70-241VICW.FR 10 MULTI CD CHIME STROBE, WALL JV1NT, RED 75 a0000 0.0000 0.1650 1.moo Peripheral Totals: 0.0000 1,6500 Added Current for E:PS.Conversiron of 24 to 29 Volt I DNac Devices 0.0000 0.0000 RUI Totals: 0 0.0000, 0,0000 Address Totals 0 Addresses 0.0000 ' 0.00Ji r t: System€ Totals : Standby 0.0850 Alarm Standby Standby Alarm Iar Battery Set#1 (Cabinet/Charger#1) Current Total Current Total Select ALL Power Supplies an thls battery seta 40,0 Q.0850, 1.8350 Sub Total 0,0$50 : 1 0350 Total 0.0850 • Standby Time = 24 Hes x 0,0$�0 2.040 0 Standby Ni. Alarm -time = 5 M.n 0:08:333 x 1.835 - 0.1529 Alarm h Additional Spare Battery 9% + 0.0000 _ , � 2.1929 Battery Discharge Factor-_ 20% 0.✓;386 Minimum Battery Required 2081,9272 &.2AH (2x) 2.6315 Battery Supplied 2081-927410AH (2x) System Totals represent total system current requirements. Those currents ma be distributed between multi le battery sets Y p_ y q .. y. _ p .tY or power suppiies as shown above, Plan .Circuit Description Load V1 1ST FLOOR CORRIDOR SIG1 0.660A V? 1ST FLOOR CORK 'M_CH T1068 SUFPLY T1047 SIG2 0.990 I I 1.650 FLORIDA FIRE PREVENTION CODE SIXTH EDITION 2017Representative s ( ) Saes a rese► to ive r i S Keviewed -NFPA 1, FIRE CODE, 2015 EDITION -NFPA 101, LIFE SAFETY CODE, 2015 EDITION DAVID R CICIRELL I MARK KANNEMEYER DCICIRELLI@SIMPLEXGRINNELL.COM mark.kannem.eyer@jci.com Y J PHONE:321-59.3=2254 PHONE:407-235-1163 FLORI_DA BUILDING CODE, SIXTH EDITION (2017) -INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION -NFPA 70, r NATIONAL ELECTRIC CODE 2014 EDITION -NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2013 EDITION Drawings Prepared By Luis Perez 'sea oee-e - lul .g r rd .p r z xt@jci,com SPRINKLER PROTECTION: OCCUPANCY TYPE(S). PHONE: 407 235 1100 I-1 Institutional Group BUILDING IS FULLY SPRINKLE D Aft S C E 0' r PROVIDE AND INSTALL 6 NEW CHIME STROBE WALL ON EXISTING FIRE ALARM SYSTEM AS SHOWN Site 0N DRAWINGS, GS CENTRAL FLORIDA REGIONAL HOSPITAL 1401 W SEMINOLE BLVD ALL WIRING TO 6E CLASS B. SANFORD, FL, 32771 + + c s 9 AUTOMATIC FIRE ALARM SYSTEM. SHALL TRANSMIT THE ALARM, SUPERVISORY AND TROUBLE SIGNALS Johnson Controls iri TO AN APPROVE) SUPERVISING STATION, THE SUPERVISING STATION SHALL BE LISTED AS EITHER , t UUFX OR UUJS UNDERWRITERS LABORATORY OR SHALL MEET THERE REQUIREMENTS OF FACTORY Q 6$30 SHADOWRIDGE DRIVE, SUITE 212 MUTUAL RESEARCH' APPROVAL STANDARD 3011, SUPERVISION OF SYSTEM AND LEASED TELEPHONE ORLANDO, FL 32812 LINES SHALT_ BE ARRANGED BY THE OWNER. PHONE: 407-235-1100 FAX: 407-235-1150 SERVICE: 407-235-1100 AFF =ABOVE FINISHED FLOOR NEC NA ELECTRIC CODE PANEL DESIGNATOR AH1 = AUTHORITY HAVING JURISDICTION NFPA NATIONAL FIRE PROTECTION ASSOCIATION + FA: = FACP NON -NETWORK ALM = ALARM NIC = NOT IN CONTRACT ANN = ANNUNCIATOR NPU = NETWORK PROCESSING UNIT + . #: = NODE NUMBER BMS = BUILDING MANAGEMENT SYSTEM NTS NOT TO SCALE T#: = TRANSPONDER NUMBER C CEILING MOUNTED #;T# = NODETRANSPONDER NUMBER = PAP = PRE -ACTION PANEL - CD -CANDELA RATING RC EXISTING TO DC"r)Vr AND CUVFR . _ + N#. -NAC EXTENDER NUMBER ^� DET = ETECTOR RD = EXISTING DEVICE TO BE RELOCATED CIRCUIT.DESIGNATOR V DEPICT GENERAL LOCATIONS F LIFE I 1, THESE DRAWINGS D IC G NERA 0 S 0 SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN DGP = DATA GATHERING PANEL RL - RELOCATED DEVICE A#: # = EPS NUMBER:IDNAC CHANNEL NUMBER lE� THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWING. E - EXISTING TO REMAIN RR -REMOVE EXISTING &REPLACE WITH NEW _..... N EUL = END OF LINE SCC =STATUS COMMAND CENTER :.. r . ,,. -• .•.: IT Ll ER ,.- .. - �. ... ,n...,.,.D#:_.�f?.I�.Q$;« 1 C1J __ 1 �_ -+ F# FIRE PHONE"CIRCUIT ('4 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK = SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE, _ = EPO = EMERGENCY POWER OFF SLC = SIGNALING LINE CIRCUIT FAA FIRE ALARM ANNUNCIATOR SMK SMOKE • _ H# AUDIBLE (HORN) CIRCUIT NUMBER, 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO : Q _ - FACP -FIRE ALARM CONTROL PANEL SUPV -SUPERVISORY .. M# IDNET LOOP NUMBER ACCOMMODATE THE RELOCATION OF EQUIPMENT OR DEVICES AUTHORIZED L Q / C S WHICH ARE AFFECTED BY ANY AUTHOR E CHANGE. ALL CHANGES SHALL BE _ FATC = FIRE ALARM TERMINAL CABINET TAC = TRUEALERT ADDRESSABLE CONTROLLER � _ P# - POWER CIRCUIT NUMBER CLEARLY INDICATED ON THE RECORD DRAWINGS. W NG5 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BEAT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 5, THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK -ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL" THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT, 6. UPDATE THE AS -BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS -BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 DAYS AFTER FINAL TEST. 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. F 8, DO NOT APPLY POWER EXCEPT IN iH_6 PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE, 9,. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST, ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER, 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED: r1_. INSTALLATION, 0F DEVICES SHALL BE INACCORDANCE WIFHMANUrACTU ER'S INrTRUvTIONrr POWER LIMITED AND NON -POWER LIMITED MITED rIEL D WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO'APPLICABLE CODES & STANDARDS' FOR SPECIFIC CODE REFERENCES. 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE S# = SPEAKER CIRCUIT NUMBER FBO =FURNISHED BY OTHERS TRBL TROUBLE FCC =FIRE COMMAND CENTER TS = TAMPER SWITCH+ V# =VISUAL CIRCUIT NUMBER _ FSD =FIRE SMOKE DAMPER TYP =TYPICAL • Z# = ZONE NUMBER FTR =FIRE ALARM TRANSPONDER LION =.UNLESS OTHERWISE NOTED 'DEVICE NUMBER H HIGH HUMIDITY VCC = VOICE COMMAND CENTER BRANCH / ISOLATED LOOP DESIGNATOR: (' IU - HT = HEIGHT VT = VALVE TAMPER • (L#) IDNET ISOLATED LOOP NUMBER HVAC = HEATING VENTILATION & AIR CONDITIONING W WATTAGE (#) = IDNAC BRANCH NUMBER IMS = INFORMATION MANAGEMENT SYSTEM W/ = WITH _ 3 LU + (E#,#) EPR NUMBER:BRANCH NUMBER MAX = MAXIMUM W/O = WITHOUT _cc = . EPS = ENHANCED POWER SUPPLY CL = MIN MINIMUM WF WATERFLOW N/A = NOTAPPLICABLE WP WEATHERPROOF 1:T2:A21-1 E1:1 2, IDNAC ADDRESSABLE NOTIFICATION CIRUICT _ _ 3. EPR ENHANCED POWER REPEATER NAC NOTIFICATION APPLIANCE CIRCUIT XP - EXPLOSION PROOF __JUJI 4 t S"S gUENKE OkF OPERATIONIS III - WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON -POWER LIMITED WIRE. Tvtals: 360 Ft. 0.99€ii 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP, -- . 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR: # 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WLT LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS y 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL CODES, WHERE APPLICABLE, 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. CTRL. UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT, 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22, MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CO S • 000NDUIT F. A CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTING WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR TO TH AS VERBAL E V CONDITION OF EXISTING CONDUITS. 5 e o o o �` 1� �` 1`b cY` ti� O �,�• �� C� �- �1 • J �. '� chi O `� � `� O `� `Z` �` �`-� C� O �. �• ® F� Q~ NAC Nl.V2 75 75 5 NAC _• V275 775 75 10K .O - NEW NEW. NEW NEW NEW NEW t. • _ C V a<1' r _ P P rr F• P � � P P O � � � J `� �X` P O �, F F � �• F �• � F � �� VT' Q 2 V a SYSTEM INPUTS A B C D E F G H I J K L M N 1 0 1 P Q, R- Sd T. U I I W I X Y 1 Z 1 AA I AB AC AD AE AF AG AH Al Al REMARKS 1 G L V2 Distributed Load Voltage Drop Allowable ° Ciro • 21.6% Per Wire: es. t R F . 0003140 @ 75 Celsius Wire Gauge: 14ga Min. Device Voltage: 16 vdc Starting Volta e. 2 .4vdc % Voltage Drop 5.64% U � p Ckt,:Capticityl 2.A Normal Operation .. Device # PIE , . Setting Distance (Feet) Device Current Voltage e C3rta.p: of a e At Device V2-1 CH70-24MCW-FR 75cd 40 0165 0.249 20.15 V2-2 OH70-24MCW-FP 75cd 35 0.165 6.430 19.97 V -3 Ci70-24MC -Fy 75 cd 70 0.165 0.720 A 0 .68 V2-4- CH70-24MCW-F R 5t 7 u 60 0.165 0.907 1 9.4 V2-5 CH70.24MCW-FR 75cd 80 0.165 1.072 19.33 V2-6 CH70-24MCW-F 7 ec1 75 0165 1.150 19.25 F_ a. LU v c� i r� a A B C D E F G H I J K L I M N 0 P R S T U V W X Y Z AA AB AC I AD I AE AF AG AH Al AJ DRAWN BY: L. PEREZ CHECKED BY: M. KANEMMEYER PERMIT 9 �..r=�.a. ISSUE DATE: 7/12/18 N.I,C. JOB #: SANP ORO FtRf DEP TMO �F-1 ii ` I r"J1 PROJECT #; 291:507611401 JOHNSON CONTROLS © 2018 r I P PLANS AFC iiEV11�111iII�U �LC!LD _ _ s A THESE P O T 6 _ P CONDITIONALLY ACC EPTIEO " IFOIR . A9J� � �U1�3 SYSTEM: OC)NI� OOFFICEE T �'IwRM{'�: AN ISSUED PERMIT SHALL BE � .,,.; . FIRE ALARM SYSTEM DEEMED PERMISSION TO Rk c b �'' ��'G C 3 s j$w L a / 4 E A J K 3 C WITH WORK AND NOT AS AUTHORITYSHEET: 7 4 A T CP TO VIOLATE, CANCEL, ALTER on SP.T. ASIDE ANY OF THESE PROVISIONS -OF 4 0 4 s P TE HNICAL CODES N` R ALt' Y GENERA J- A 0 THE G O '" L INFORMATION - ISSUANCE OFAPERMIT PI IwV' `iTH REVIEWED BY: L S P E . c I FIRE PREVENTION DIVISION, FROM o MATT MINNETTO E REQUIRING ' �4 s F E EC�It,tIRI l THEREAFTER +�, CORRECTION Q I�ROI�$ ON THE � ::�--' . - � I- Z Z MX , TI R 4T<1R 1ST FLOORQV ----_•v- �-�-- _- _. I ST FLOOR PLANS, C ONSTRUO 014 O SANFORD FIRE DEPT. 1 VIOL.ATtC)NS OF THE CODE . DATE: 11 SMOKE SENSOR/DETECTOR . 1 a 1 1 a 1 e a• m 1 2 MANUAL PULL STATION 2 3 HEAT SENSOR/DETECTOR • ® ® • 3 4 DUCT SENSOR/DETECTOR ® o • , . • 4 5 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR . ® • ® ® ®; .® • • a • o 5 6 ° ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR,) 0777p • 6 7 ELEVATOR MECH. ROOM HEAT DETECTOR ® • ® ® • • ® Q 7 8 ELEVATOR MECH. ROOM SMOKE DETECTOR • • e • • • • • -e g . ® m 8 9 ELEVATOR SHAFT HEAT DETECTOR • • • ' • • g 10 ELEVATOR SHAFT SMOKE DETECTOR • • • • • • • • • • • • 10 11 ELEVATOR POWER MONITOR • ® • • • . 11 12 WATERFLOW SWITCH • • « • . • • 12 13 TAMPER SWITCH • ® • ® ® . 13 14 POST INDICATOR VALVE SWITCH • • • • • • 14 151 FIRE ALARM AC POWER FAILURE • • •_4 • • 15 > 161 OPEN CIRCUIT OR GROUND FAULT • • • • 16 17 FIRE ALARM SYSTEM LOW BATTERY s • 4_17 18 CLASS B NOTIFICATION CIRCUIT (NAC) -SHORT • • • • • 1 g 1111 VI L011L IIULK.0 LV MCI. D � tll.l,C LIII VI um Lulls. u1dWlll dllulul uw 11IIUIliiduun.CVuLdiileu nulelil ule user ai lees W Lne following terms aria coriaiiions: i ne eleC conic information in me drawing r N � N y y y r .i 9 t t t aw rig may De suolect to mtenuonal or unintennonai alteration. Any use, reuse, copying mogincation or alteration of the intormatron contained herein shall beat the sole risk of the user. This information may not be sold or transferred to any third party, used on other or additions to the project for which r P t A A projects p) t hi. t was prepared, o, used for completion of this project by any third party: Johnson Controls disclaims all liability for the use or reuse altered files h the user or an third art and such use will be a user's sole risk User shalt; to the extent permitted b taw, defend indemnify, and hold Johnson Controls harmless from an and all claims damage Y Y Y. party P Y fy, y am ge or injury arising directly or indirectly therefrom, a, { Q V V L 2 - Fr)11� cn m CD C w C7 0 k tA.. J NEW - 1 EOL NAC1—V2 a n n — — 10K cr) y r NEWFIRE ALARM SYMBOL v SaL T� 7 � MIL ' SUPPLY vo I r/ r//// CHAIN A SYMBOL I DESCRIPTION BRAND MODEL sox CODE WIRE TYPE PANELS & ANNUNCIATORS NAC# EXISTING 4009IDNET NAC EXTENDER PANEL, BEIGE,120 VAC / W/ 10AH BATTERY SIMPLEX 009 49201 2081-9274 MFG NOTIFICATION APPLIANCES MULTI -CANDELA CHIME/STROBE, WALL MOUNT, RED, FIRE, CLEAR LENS WHEELOCK CH70-24MCW-FR 4L 4 V MISCELLANEOUS DEVICES SA EXISTING, SYNC FLASH MODULE CLASS B WHEELOCK DSM-12/24-R DS 10K-V* EXISTING, END -OF -LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 NR SS P EXISTING,120/240V -15A PARALLEL PROTECTOR DITEK DTK-120/240HW-SS NR RACKROX CODES CODE I BOX SPECIFICATIONS CODE BOX SPECIFICATIONS 4A 4" SQ. BOX 11/2" DEEP 1E ISINGLE GANG BOX 21/2" DEEP 4F 4" SQ. BOX 1112". DEEP W/ COVER 1F I SINGLE GANG BOX 21/2" DEEP W/COVER 4C 4" SQ. BOX 11/2" DEEP W/ 11/2" EXT. RING 1G SINGLE GANG BOX 2 3/4" DEEP 4D 4" SQ. BOX 21/8" DEEP: 1H SINGLE GANG BOX 31/2" DEEP 4E 4" SQ, BOX 21/8" DEEP W/ COVER 2A I DOUBLE GANG BOX 2" DEEP 4F 4" SQ. BOX 21/8" DEEP W/ 110" EXT, RING 2B ITWO GANG BOX 21/2" DEEP 4G 4" SQ. BOX 21/8" DEEP W/ SINGLE GANG COVER 2C TWO GANG BOX 2 3/4` DEEP 4H 4" SQ. BOX 21/8" DEEP W/ TWO GANG COVER SA 15 GANG BOX 21/2" DEEP 4J 4" SQ. BOX 21/2" DEEP, 6A 16 SINGLE GANG BOXES 31/2" DEEP 4K 4" OCT. BOX 11/2" DEEP 6B 16GANG BOX 4L 4" OCT, BOX 11/2" DEEP W/ 11/2" EXT, RING 6C 16 GANG BOX 21/2" DEEP 4M 411/16" SQ, BOX 21/8" DEEP 6D 16 GANG BOX 31/2" DEEP, 4N 1411/16" SQ. BOX 11/2" DEEP W/ 11/2" EXT. RING FBO FURNISHED BY OTHERS 4P 411/16" SQ. BOX 21/8° DEEP W/ 11/2" EXT. RING MFG SUPPLIED BY MANUFACTURER 4Q 4" SQ. BOX 11/2" DEEP W/4098-9832 ADAPTER MDW MOUNTS TO DUCTWORK 4R 4" SQ. BOX 11/2" DEEP W/RACO 787 OR EQUIV, MBD MOUNTS IN BOX BEHIND DETECTOR 4S, 4" Q. BOX 11/2" DEEP W/4098-9863 ADAPTER WM IWALL MOUNT . 1A SINGLE GANG BOX 1112" DEEP DT DESKTOP MOUNT 10 ISINGLE GANG BOX 2" DEEP DS REFER TO PRODUCT'DATASHEET 1C SINGLE GANG BOX 21/8" DEEP NR NO BACKBOX REQUIRED -1D SINGLE GANG BOX 21/8" DEEP W/COVER TRM 3.5" WIDE SNAP TRACK W/MOUNTING SCREWS FOR ADDITIONAL BACK BOX OPTIONS, REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND INSTALLATION INSTRUCTIONS, FIRE ALARM WIRE L1540T ACCEPTABLE CABLE TYPES 0 o CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES v K REMOTE TEST SWITCH/LED (2) 2 COND. STRANDED 14 AWG X X X M IDNET UTP SOLID 18 AWG X X CONDUIT SIZE I MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA NOTES 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH x *40% FILL PER N.E.C. 3/4" 0.21 SQ INCH x 1-1/2" 0.82 SQ INCH * SUBSCRIPT "u": UNSHIELDED CABLES MIXED WITH 1,, 0.34 SQ INCH 4 2" 1.34 SQ INCH SHIELDED CABLES OF SAME CIRCUIT DESIGNATION. **OUTDOOR AERIAL CABLE REQUIRES MESSENGER ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS,ARE AVAILABLE UPON REQUEST. _ I 1 .o \ U N \ J J m ,o N1:V2-2 NEW 75 r 1 m r I ® SCALE: I/8u =V-Ou I • ® a� Q C. o 1 -� • (D w � un r~) q0 a REVISI 1 • Lh a DRAWfV BY: L. PEREZ CHECKED BY: M. KANEMMEYER ISSUE DATE: 7/12/18 JOB #: PROJECT #: 1 291:607611401 7JOHNSON CONTROLS ©2018 �lI • Q h� SYSTEM: ' FIRE ALARM SYSTEM` . r SHEET: , DEVICE PLACEMENT PLAN N KEY PLAN SCALE: NTS P 1 art used an other Important notice to user: B accepting or using this drawing and/or the information contained herein the user agrees to the following terms and conditions: The electronic information In the drawing ma k�_ subject to intentional or unintentional alteration.. An use, reuse; copying modification or alteration of the Information contained herein shall be at the sole risk of the user, This information may no. be sold or transferred .o an third party, u L / PY 9 Y P Y P 9 9 9 g 9 ;. 9 Y J T T _ P p � r T A fT the p d such use well be a user's sale risk. Usershall to the fullest extent permitted b iaw, defend, indemnify, and hold Johnson Controls harmless from an and all claims for loss damage or injury arisen direct) or indirect) therefrom. protects or additions .o tn.. prole_. ror which it was prepared, or used for completion of this project by any third part}. Johnson Controls disclaims all liability for .n� use or reuse of altered files by the user or any third party an p y fy, y y J ry g y y SYMBOL I DESCRIPTION BRAND MODEL Box CODE wlRE TYPE PANELS &,ANNUNCIATORS EXISTING 40091DNET NAC EXTENDER PANEL, BEIGF, 120 VAC / W/ 10AH BATTERY SIMPLEX 4U09-9201 2081-9274 MFG NOTIFICATION APPLIANCES MULTI -CANDELA CHIME/STROBE, WALL MOUNT, RED, FIRE; CLEAR LENS WHEELOCK CH70 24MCW-FR 4C 4L V INITIATING DEVICES El SINGLE ACTION MANUAL PULL STATION SIMPLEX 4099 9004 4G lE M O ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR WITH STANDARD BASE ' SIMPLEX4098-9714 HEAD 40%-9792 BASE 4K 4R M MODULES & RELAYS TRACK MOUNTEDSINGLER LAY DPDT W/ ENCLOSURE, INC SIMPLEX 2088-9010 TRM R RELAY IAM SIMPLEX 4090-9002 4H M R MISCELLANEOUS DEVICES 10KN EXISFWG, END-OFAINE RESISTOR IOK (EOL) SIMPLFX 4081-9008 NR JB JUNCTION BOX BY OTHERS BY OTHERS F80 BACKBOX CODES CODE I BOX SPECIFICATIONS CODE BOX SPECIFICATIONS ;.. 4A 4" SO. BOX 11/2" DEEP 1E SINGLE GANG BOX 2112"DEEP 4B 4" SQ. BOX 11/2"_DEEP _W/ COVER IF SINGLE GANG BOX 21/2" DEEP W/COVER 4C 4" SQ. BOX 1_1/2 `DEEP W/ 11/2" EXT, RING 1G SINGLE GANG BOX 2 3/4" DEEP 4D 4" SQ. BOX 21/8" DEEP 1H SINGLE GANG BOX 31/2" DEEP 4E 1 4" SQ. BOX 21/8" DEEP W/ COVER 24 DOUBLE GANG BOX 2" DEEP 4F 4"SQ.BOX 21/8" DEEP W/ 11/2" EXT, RING 2B ITWO GANG BOX 21/2" DEEP 4G 4" SQ. BOX 21/8" DEEP W/ SINGLE GANG COVER 2C TWO GANG BOX 2 3/4"- DEEP 4H 4" SQ. BOX 21/8" DEEP W/ TWO GANG COVER 5A 15 GANG BOX 21/2' DEEP 4J 4" SQ, BOX 2112"DEEP 6A 16 SINGLE GANG BOXES 31/2" DEEP 4K 4" OCT. BOX 1112" DEEP 6B 6 GANG BOX 4L 4" OCT. BOX 11/2" DEEP W/ 1112" EXT. RING 6C 6 GANG BOX 21/2" DEEP 4M 411/16" SQ. BOX 21/8" DEEP 6D 6 GANG BOX 31/2" DEEP 4N 1411/16" SQ. BOX 1112" DEEP W/ 1112" EXT. RING FBO: FURNISHED BY OTHERS 4P 4 DAV SO. BOX 21/8" DEEP W/ 11,1T EXT. RING MFG SUPPLIED_BYMANUFACTURER ' 4q 4" SQ. BOX 11/2" DEEP W/4098-9832 ADAPTER MDW MOUNTS TO DUCIWORK 4R 4" SQ. BOX 1112" DEEP W/RACO 787 OR EQUIV, MBD MOUNTS IN BOX BEHIND DEFECTOR 45 4".SO, BOX 1112" DEEP W/4093-9863 ADAPTER WM WALL MOUNT lA I SINGLE GANG BOX 1112" DEEP DT DESKTOP MOUNT 16 SINGLE GANG BOX2"DEEP DS REFER TO PRODUCT DATASHEET 1C TINGLE GANG BOX 21/8" DEEP j NR NO BACKBOX REQUIRED ID SINGLE GANG BOX 21/8" DEEP W/COVER I TRM 3,5" WIDE SNAP TRACK W/MOUNTING SCREWS FOR ADDITIONAL BACK BOX OPTIONS, REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS AND INSTALLATION INSTRUCTIONS. : ::' .. / 7 ... ALARM WIRELIST ACCEPTABLE CABLE TYPES a . a ca o H CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES K REMOFE TEST SWITCHAED (2) 2 COND. STRANDED 14 AWG X X X M IDNET UTP SOLID 18 AWG X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA NOTES 1/2" 0,12 SQ INCH " 1 1/4'" 0.60 SQ INCH' *40% FILL PER N.E.C, 3/4" 021 SQ INCH * 1-1/2' 0,82 SQ INCH * SUBSCRIPT " u", UNSHIELDED CABLES MIXED WITH 0.34 SQ INCH' 2" 1.34 SQ INCH * ` SHIELDED CABLES OF SAME CIRCUIT DESIGNATION. **OUTDOOR AERIAL CABLE REQUIRES MESSENGER ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST, z z z, z/ z z r _ _ OL D OF L # 1 EN E E IN SLC SIGNALING LINE CIRCUIT F FIRE PHONE CIRCUIT U N EP0 = E`MERGENCY POWER -ER0FF SMK _SM E H # _- B AUDI LE (HORN) CIRCUIT NUMER GENERAL NOTES� NEW FAA =FIRE ALARM ANNUNCIATOR SUP = SUPERVISORYM# IDNET LOOP NUMBER 0-4 Mx-' +1 FACP_ FIRE ALARM CONTROL PANEL LAC - TRUEALERT ADDRESSABLE CONTROLLER P# POWER CIRCUITNUMBER 0. 9- s FATC ; FIRE ALARM TERMINAL CABINET " TRBL =TROUBLE F MAIN S SPEAKER CIRCUIT NUMBER V M K r _ ; + FBO FURNISHED BY OTHER TS TAMPER SWITCH , MX XX 1 ELECTRICAL C L 1: THESE DRAWINGS DEPICT GENE AL LUCA IO S 0 LIFE � E LE TRI A , R N F LI SAFETY EQUIPMENT FIELD DE C S' 0 0 T Y MEN & FI L VIE . EXACT ROUTING OF C NDUITS I5 TO BE DETERMINED ED IN Q RM N . F # U V VI CIRCUIT NE W _ SAL IR UIT NUMBER r _ _ FCC FIRE COMMAND D CENTER E FIELD B S ` R M AN T R TYP TYPICAL THE FIE Y THE INSTALLING CONTRACTOR0 SUIT .0 DITIO S L CHANGE" R00 Z T T N .A GE SHALL CLEARLY 0 M N L HA HA L BE L ARLY INDICATED ON THE RECORD DRAWINGS: taK N R _C NLV3 � I . Z ZONE NUMBER 5D - S 0 D S NE N M ER Z, SHOULD Y CONDITIONS E IS UI 0 S - F FIRE M Kr; AMPER UON UNLES OTHERWISE NOTED ANEXIST THAT DIFFER FROM WHAT I I D C O S D US F R M W A N I ATED N THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS I T 761EW IA S N E O T THE V M 6 DEVICENUMBER, ,; I E TRANSPONDER DE R R LA C CCU D- 'SHOWN THE CONTRACTOR SHALL CONTACT J M , FT F ALARM TRAN P N R VC VOICE COMMAND CENTER 0 0 , RA R TAT HNSUN CONTROLS IN A TIMELY MANNER SO AS 0 0 NOT T IMPAIR THE CONSTRUCTION SCHEDULE. .: B ISOLATED ELECTRICAL:.. : _ - . _ : RANCH I ATED OOP DESIGNATOR: G U D Y _ V H HI H H MI IT VT VA_V_ TAMPER I, :3 CONTRACTOR S RESPONSIBLE F G J v ONTRA TUR I RE PON IBL_ FOR MAKING AND OBT AINING APPROVAL 0 D .. - _. T P VA_ FOR A__ NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO I - _ _ - _ ' , ' ¢ -L 2 e F HT HEIGHT GE # W W 0 WATTAGE L IDNET ISOLATED LOOP UMBER 0 N ROOM NEW r - ACCOMMODATE THE RELOCATION OF EQUIPMENT D U _ r M AN DEVICES D R V WHICH ARE AFFECTED BY AN AUTHORIZE CHANGE: ALL CHANGES SHALL BE / I F Y G V C >W MX XX 1 cr , _ _ HVAC HEATIN ENTILATION &AIR ONDITIONING WITH O I NA RANCH NUMBcR _ C � P N 1 A- - � S F F '� CLEARLY DC � _ 3 L RLY INDICATED ED U RECORD DRAWINGS. GS S � �. A AT N THE R R RAW N I ., W 0 IMS INFORMATION MANAG E T S S EM Ui I EM N Y T WITH 0 z z z a ,V9 O` RM E# E PR NUMBER.6 ANC U _ _. _ R H NUMBER F x M NEW x p ( rr F �a c� �� _ � MA MAXI U T EDP 0 APPROVED _ L DRAWINGS S L B X M M WF WATERFLOW , 4 A AMP ET F APPR V D FIR ALARM RAWIN S SHALL B AT THE JOB SITE AND SHALL E USED FOR INSTALLATION _ '. E T N R . _ I _ VM �, _.� P 1 EPS ENH ANCED C 0 M 106 I HAN EDP POWER SUPPLY T + M c� '. MX XX 1 �r r s nx r 'O. x x 1 -: MIN MINIMUM „ ,. WG ..WIRE GUARD _ 75 z - z z ' -F 5. THE POWER CIRCUIT TO THE FACP AND TOz N T FIRE L 0_ SUPPLIES S S B C B BREAKER, HE F R ALARM POWER R P E HALL E ON A DEDICATED 120V 20A RANCH CIRCUIT AND FIRE PUMP 75 ,� ,� _. - 2 IDNACADDRESSABLE0 N r � 1.T�.A2:1 1. E11 TIFICATION CIRCUIT N, w 1 V3 5 � t-- N NEW -� A OT APPLICABLE N 0 F F / ` WP WEATHERPROOF i, - _ NEW : SHALL H VE A RED MARKING, LOCK -ON 0 PROVISION D S B IDENTIFIED L V M R N P N AN SHALL E I_ IFIE S "FIRE CIRCUIT CONTROL." 0 A K R I HA NT A F R ALARM R T NTR L THE LOCATION OF THE CIRCUIT _:. _, � : ca _ ` R ROOM rnx x i a _ 3. EPR ENHANCED 0 - � x � FPOWER REPEATER r r� NAC NOTIFICATION APPLIANCE CIRCUI E 0 F NEW W- ; ` NLV3 3 � v � T XP XPLOSI N PROOF DISCONNECT (CIRCUIT 1 UNNECT MANS IBC IT BREAKER) SHALL U .-.� - �r - R A E PERMANENTLY IDENTIFIED H E L CO I x H P LAN NTLY AT THE FIR ALARM CONTROL UNIT. E I` _ V � -- � W I _ 2 _ DU D M G_ G G N NETWORK DISPLAY UNIT 6. UPDATE THE AS -BUILT DR AWING A G S� DAILY 0 PROGRESS. T R WIN T AI Y WITH JOB PRO RE S. RETURN E AS -BUILT DRAWING SET 0 J0 SO CO L� 0 E R THE TT N CONTROLS LATER THAN / AH N R N T T ' ` a M - - , VIM "��Q �. , i VIM VM � D PA F AY5 AFTER FINAL TEST. A I F t1� . T ate. /. THE CONTRACTOR WILL MAINTAIN ALL AREAS 0 �- A F THE BUILDING IN A NEAT AND WORKMANLIKE MANNER, IL FtdAVM 4 0� 0� G 0 J8 (3- a.: o 0 r- '4E OF SYSTEMSEqUEN UI D APFACTORY NOT PLY POWER EXCEPT IN THE PRESENCE OF A JO SO E HN N REPE\ESENTATIV . NEW r-, 15 4: c o B F E j: ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING G 5 D D _ H B IL iN I CLEANED AN ACCEPTED SHALL BE COVERED TO PROTECt FROM DUST. ANY FALSE _ >< X n NLV3 4 75 x x LA U Mx XX 1 VM ALARMS DUE TO S ,: DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE IRE INSTALLER. 3 .� .. .� E R N F ALARM I TALLER. N1,V z J I Q NEVI M VM , NEW NEW NcW 1 1 Iv NEW _ _0. E THE FIR ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE G 0 L CEILING, D SS A E INTEGRITY F ALL WALL, C I ING AN ROOF ASSEMBLIES ANY TIME THAT WORK IS ` ° \ MK xX i V CTRL. UNIT ANNUN C M T N NITIONOTIFICATION � N A A N : IRS CONTROL _FIRE SAFETY NTR L PEN MX XX+_ . M _I NOT ACTIVELY BEING PERFORMED. _ LW F S To lce. c) 11. INSTALLATION OFDEVICES S L _LIMITEDM 1 !a . A N L BE INACCORDANCE U S 0 b HA WITH MANUFACTURER'S S INSTRUCTIONS. NS. POWER LIMITED AND NON PO EFIELD W RFI _ I .3 a N 1f 1 � EMERGENCY 1 ,." M ALAR :, MAIN I G 0 , W RI UST I L D S � N M BEINSTALLED E WITHIN THE FACP ENCLOSURE IN ACCORDANCE I MANUFACTURER'S INSTRUCTIONS D NEW A WITH MAN FACTURER IN TRUCTI NS AN APPLICABLE ELECTRICAL � a�J ABOVE ➢iTW GENERATOR Mx xx TELL ENERAT ft F 0 Mx xX 1 ELECTRICAL o OD q- C ES. REFER TO'APPLICABLE LI ABLE -COD D S D S � .--- PP ES & STANDAR S FUR SPECIFIC CODE REFERENCES. C - M � ROOM O R c� M rLU � F M O C ROOM 2 F TROUB LE C� LF 9 _ ROOM 1 ti F � 12. A WIRING 0ALL W SHALL B S I HA L E INSTALLED ACCORDING TO ELECTRICAL � 1 A , T1069 O F h F MX XX 1 C� ; _ r C, p F \ c EMERGENCY O � 13, FIRE ALARM CIRCUITS SHALL BE I ENTIFIE IN ACCO D C, > ti .,,❑I R A Cr C C`, D N WITH APPLI ABLE ELECTRI AL CU ES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE _ M O F 1 C� O ti F O NE W O G _ ti O SUP RVI 0 � E � P _ _ v WI GENERA R �Cn T APPLICABLE BL ELECTRICAL C U H P A E LE TRI AL CODE SECTIONS FOR POWERlI LIMITED AND NON -POWER ER LIMITED WIRE. 0 + _ �, M T T R ti ': P W MX xX l � ti � _ J Q � - MX _ � XX F Q , � ti C, /J _ O S � F O J \ G .G C INSTALLED DUCTS, V V 14 FIRE ALARM ABLE IN TALLE IN TS PLENUM AND OTHER SPACES USED OR ENVIRONMENTAL ROOM .. � . \ � � � SP E R T P R A F NMEN AL AIR SHALL BE PE FPLP. TYPE F , O � � O Q � O � ti P Q a STORAGE `z a � Q c F 5_ U. FIRE ALARM CABLE INSTALLED I -. N THE IC US D PENETRATING TH VERTICAL RUNS AN P N TRATING MORE THAN ONE FLOOR OR CABLES 5 INSTALLED 1 � A E IN ALLE I � c T N VERTICAL RUNS IN ti _- O : FUEL PUMPS � � O C., O < � X SHAFTS SHALL BE TYPE F LR. 1 , P Q O _ _ O _ � w ti H � O F 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER LOCATIONS NSSHALLBEUL LISTED FOR WET LOCATIONS' NS. � � O O O \ ti 1 ti Q 17. FIRE ALARM CIRCUITS EXTENDINGBEYONDO � F DI 0 ONE AND RUN UTDOORS SHALL BE I L N APP APPLICABLE ELECTRICAL 0 0 Q � A P F i ti J CODES WHEREAPPLICABLE. . O \> O J O O Q F J � C, 4 � F O O F F F_Q P i F \� O � 18. ALL WIRING, INCLUDING G SHIELDS MUST BE DRY AND OF SHORT ANDGROUNDS.LU JF F Jt F P F F F F F F �a O - J C L _ ti t J t F L L O � G\ _ F Cr C.. � C, (.. C, C, O O : a 1 � 1 PARTIALl L �� P _9. ALL S SHIELDED S P O �\ �, � WIRE U S �` H R MUST HAVE SHIELD CONTINUITY AT FULLIE LENGTH oFT E WIRE. F F � Q �- � � e N T H R F_F F � _F � _ _.._ _ _F -F F-� F F F� 2 S _ CAE.18 0 k 1 r U. 20. 0 SYSTEM ' SYS U L SSYSTEM INPUTS ONLY CAN BE RUN IN THE SAME / M T B C D E F G J L 0 - A H I N S K M_. _ P R T U V_ W- X_, Y Z AA AB A_ AD AE AG ` nlatroc � r�rntn AF AH AlAI AJ REMARK ` ®-SMOKE - SENSOR/DETECTOR _ cnmmmmmmmmmn non® MANUAL®A • ovmmmo®a�moommmmmmmvtrmm mnrnmmmm�mmmm®o© ®HEAT SENSOR/DETECTORdo®mm®ontsomoomm®-mmma�mimm®mmmm mmmmA® o , • • moom®rrcirrm®rrnomr nmmmmmmmm®a■■■■®rmsrm mn ono ® • • : mommmmdmmmnmmmmmo mmmmnmmmmmmmmmo nnn r� . o : � • • • mermsi®rdaim■roommmmomm®®�®®®mmmmnmmnresaa® � ® .,• 1 DETECTOR orormmmmomomomommmmmmmmmnmmmmmmmmmmmmrom ELEVATOR • • DETECTOR oommm orcnormcncirmammam�amormcnmmmmmm-mm aaa�ro ® , • DETECTOR mmmrmiironmmnnmmmmmmmmmommmmmmmmmme�iimnno ®ELEVATOR SHAFT SMOKE DETECTOR oommmmmrrcrrrcnm nm■nmmmromnmomomm mmmmmmcnnnnm ® • .. • • M#NITOA mmrarrarmmm®-mormmrmmmmmmmrr=nmmmm ®mmmmmmmmm® m oeanrrn�nmmEnn nmoommmmommm mnmm mmmmmmmmnnm ® TAMPERm®momm®®mmomrormmmmmmmmmmmmmmmmmmmmmmo® m POST INDICATORmmorommommmo®rcirmmmm mmmmmmmmmmmm®mmmmd�m. mFIRE ALARM AC POWER , mmmmnanm®mmmommom®m®®mmor®®®nrr®smmm®mmm® m CUIT • . GROUND FAULTmmmmmommmm®mm�smmm®m®mmmmmmmmmmmmmmmr0m ® • ALARM • BATTERY m mmn�rrommmm�nmm®mmmmmmmmmmm®.mmmm®mmm®® m :• • • m�iimmnnmmmmnmmnmmmmmmmmmmmm®mmmmr mmm®m C _ �K : 7 7 7 l: L A 8 C D E F G I L K L M N 0: P Q R n� U V W X Y Z AA AB AC AD AE' AE AG A AI AJ CALCULATIONS r M O Z Z Z7- 1-Z Z�-z T >--v , � M EXISTING I-DNE T T I r Q Qry �0h F s s or oh o ..NAC N1. 1 V 4 - ::'1, t`b .\ rib .., r� .'\.,o .'\, t_� r`_i�. .. _'ti 1. _.1 , � 10K ,, M 4009 ti /CE,� XtiIS-TI N G CIRCUIT/ � `y N-A C Nly.V 1 /N�1�Y V:.1 q O O Q V r f \ _ t ! i e � i F � � _ r , 4 2 V� r� Y V l 3 /� C "� �.. `� : "� '� j '; � T D D '!- S 1 4' � C � _ _ \ F, F o . \ t_ k� L-- _� \ r c CONTROL -T,rMP CONTROL EXHAUST FAN EX AUSTFAN C AL D G r F N C1 T ENTR LDRI ARi; 10 AL ! yF?L 4D09: AC , F RL N VOLTAGE DROP SUMMARY ,... P M RY M A ass 5 are :. P capacity YF vw , ; ��. StandbY Tatal AJarm Total M_a.d..ule .. t Description �t.Y n Current r nt Standby CUrr®ntAlarm PlnN:I.C: C cm De scription tlon L jd : 1Dro p P vvs1 i5 FLOOR q CORRIDOR„IOi 0.660A 3.71 / 67.0.00 Pan@l rUI r@1t _ T FLOOR RR MECH T10 6 SUPPLY T10a7 SI 2 .9A 5. 50.501 FLOOR ELECTRICAL RM FIRE slGa o.990 a.5a° 50 50 :EXTENDER120 VAC 40U92U1 1 '4009IDNET NA,Lt80 85r 0�850 04R50 V4 SPARE SIGa O.000A 0.00/ 100NA 0 E IS G X TIN 2 ao Panel Totals -0.085 6 A N,I.C. - 0 0:185.0 v : OC D M L A TE IN PLANT Notification Appliances. No of a set ting n �I? t 4J 0PRAI NF10 61 E T 0 r c c H70241�1 W R 1fi (v�JLTICQCHIIvL� TROB WALL- T D F S MN R E 7 0000 0.1650 2.6 00 0 4 2 T _. _ . __ 5 U;OGO tJ, V C`. P Peripheral Totals .O,O000 1.6 0 40 ` _ ., Added urrentful EPS Conve t 19 D e _ r ro f 4 o Vr, t l av evic. s s. na 2 I DN 0 U.UU U 0.0U00 .. RL Totals 0 0.0000 0U ' Q:0000 Address Tota s 0 Addresses <: t 0.0000 0.0000 a w ",. 5 sfom Totals Standby Y Y 0 _0850 Alarm 8 5D 2, 2 _ N . I : C . StandbY Y Standb Alarm Alarm Eatte Y Se#1: IC^abi etlC ar4e r71) Curs t. Tcal Current Total 6 S lect AL.L Power 'Su alien on this batter 'set: 4000 _ 0.08 0 2.825 0 . I P A : S b Total u 0.08a 50 0 8 50 2, 2 P T 6 E T T otal 0'.0 5 Ii 0 2.8250 1 4 E A J K ' C StandbyTime = 24 HLs x OQaO _ 2.0400 StandbyA1_3 V3 Distributedo- o a e Drop P Allowable Dro /0 P . , Wire au e. 9 Starim Voltage: Ca ci Ckt Capacity p Y - 6 o 21. / 6 14 a r3 20,4vdc 2.A ;: ' Wire Res, Pe Ft . r Min, Device Volta e. s o Voltage Drop 7 0 0.003 0 5 Celsius 14 C 1svaG 4.54/ orrnaOperation Device # PIE) Settin 9 Distance Feet Device i Current Voltage 9 Drop oage J Device V3-1 CH70-24MC -F W R 7 5c d 82 0.1fi5, 0,510 19.89 V3-2 C 7 -Z C _ H Q QM W FR 75cd 25 .1 5 0,165 0.639 9 1 .76 V3-3 CH70-24MCW-FR 75cd 19 0.165 0.718 19.68 V3-4 - 70 2 CH 4MCW FR c 75 d 3 4 ' 0.165 0.852 19.55 V -5 3 C H70 24MCW FR 176cd 20 0.165 0,893 19.51 V3-6 - C 0 H7 24MCW FR c 75 d 31 0.165 0.925 19.47 F- a q - x a REVISIOND 1 DRAVJN BY: L PEREZ , CHECKED BY: M. KANNEMEYE R ISSU_F DATE 9 14 18 JOB #; .� PROJECT 191., 6U8U80001 JOHNSON CONTROLS ;O 2018 SYSTEM: