Loading...
HomeMy WebLinkAbout110 Belgian Way - BR18-003649 - WINDOWSJob Addre Parcel ID: CITY OF Sk FORJYU621 20 PERMIT APPLICATION BUILDING DIVISION Application No: 3- 304 " Documented Construction Value: $ 6 ( 96 I' Q0 Historic District: Yes No[--] Residential ommercial Type of Work: New Addition Alteration Repair ElDemo Change of UseEl Move Description of Work: I I w h&ws 5, -6- Si?1L COr1ofm uoi% xTi y6C Yilvnw RqM., l..)w 1A 11_6 r fn0MW71ff- o040 ad SNGC moo wr/) 04 • a6 Plan Review Contact Person: An L el 11A, Title: /Q Arm; m i Phone: 7-%, 10 - j597 Fax:-Y30'/S98' Email: CWb q( /OaOJ' U nd)OWS•COO) v Property Owner Information Name X Narc im# s Phone: go7- 376— 5310a Street: 110 PAa i nki WM Resident of property? : yes City, State Zip: I VZ • -307 7 5Contractor Information Name rc oQ1lll 6— f-wk#_ Phone: qQ7 _93-I599 Street: lea NWYIMq hadA S(ni 46 621 Fax: L 07- 930--15 9 S City, State Zip: (()OOA o I State License No.: eGC I50L 010 Architect/Engineer Information Name: Phone: Street: Fax City, St, Zip: E- mail: Bonding Company: / Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. d--'i. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6" Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that 1 will notify the owner ofthe property ofthe requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done applicable laws regulating construction and zoning. i7< `L61 0Z/ /8 ign re of er/Agent Date Signature of Contractor/Agent Date o e' N' e S Dew' G- (3ax r Print Owner/ a Print Co /Ag t' Name- Signatur of No rY to of4 o a Date Signa re'f r "•;= H. NATHAgMEISTER i MYCOMMISSI N#FF168625 d!A ? EXP ES November 16, 2018Osi„ Ow r IL IS f I ff"M Me or Contractor "' 'ais Re rW irrtcvtlto a or jakProtd1CE"C'$1f31DF 1.C• Produced ID Type of ID EXPIRES November 16, 2018 407) 398.0153 FloridallotarYServiCe.com BELOW IS FOR OFFICE USE ONLY Permits Required: Building [2 Electrical Mechanical Plumbing Gas Roof Construction Type: Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: Flood Zone: of Stories: New Construction: Electric - # of Amps Plumbing - # of Fixtures Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: ENGINEERING: COMMENTS: UTILITIES: FIRE: Fire Alarm Permit: Yes []No WASTE WATER: BUILDING: -51 '-1149 REQUIRED INSPECTION SEQUENCE B P# - Addi , UMQs I U$1' • n 1 I[ax Insfeecdom IIDescri Lion Footer / Sefback Stemwall ' Foundation / Form Board Survey Slab / Mono Slab- Pre our Lintel / Tie Beam / Fill / Down Cell Sheathing _ Walls- ancuunng— ADM, RoofDry In Frame Insulation Rough In Firewall Screw Pattern i Drywall / Sheetrock Lath Ins ection Final Solar Final Roof,-. Final Stucco -/,Siding Insulation Final Final Utili ' ' Building Final Door Final Window Final Screen.Room Final. Pool Screen Enclosure Mobile Home Building Final Pre -Demo Final Demo Final' Single! Famil ; Residence Final. Building (Other) Electric Underground Footer [Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final e Iffin Ida' Ilnseection IIDesc iEtion Plumbing Underground Plumbing Sewer Plumbing Tub Set Plumbing Final 4l^.eVd:r lC ic;iRlvLLCC '^.c• 'i' 1'.:•*ns' t F' ^;•i min Max IMSIRectiom DescriRtion Mechanical Rough Mechanical. Final Dun I Max Gas Underground Gas Rough Gas Final REVISED: June 2914 Grant Maloyy Clerk Of The Circuit Court & Comptroller Seminole County, FIL Inst #2018068777 Book:9200 Page:582; (1 PAGES) RCD: 8/27/2018 10:59:23 AM REC FEE $10. 004t THIS INS aYName•jAddress ZOccNOTICEOFCOMMENCEMENT` State of FloridaCountyofSeminoleWoPermitNumber. Parcel ID Number. (g —2n-31—.S — 0000- n x = ccW The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance withtJ Chapter 713. Florida Statutes, the following Information Is provided In this Notice of Commencement. DES RIPTION OF PROPERTY: (Legal description of ther,erty an street addres If a liable) i- al f3 Ke,rs _rts tna 4) R % 60 G ,27 -2 9 GENERAL DESCRIPTION OF IMPROVEMENT: iblIlY. X1 S(l'y. -for S%L9 OWNER INFORMATION: _ Address: IIIJ Uelokajn n-fora. r Fee Simple Tide Holder Of other than owner) Name: tj Address: Address: Persons within the State of Florida Designated by Owner upon whom notice or other documents may be served as provided by Section 713.13(1)(b), Florida Statutes. Name: 0-141VYt A - In addition to himself, Owner Designates ! 11u1.r"10A7 /vlLr tS""— of 24X I&I' 11 7iS GWd Q0005 To receive a copy of the Llenors Notice as Provided In Section 713.13(1)(b), Florida Statutes. Expiration Date of Notice of Cominr encem nt (The expiration date is 1 year from date of recording unless a different date Is specified) 1113/ ] WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE MENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPE ON. If - IOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BFFORIE CO NG WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. that 1 have read the foregoing and that the facts stated in It are We tom- 0 !iltnw AA ownn. rs vdnted 713. 13(1o):' The ormer mum slpn the nadw of oommen=n*W and no one efts may be pemdeed to den In his or hm tteaV State of Fbht c A' County of -4x— J "00\L The foregoing 1instrument was acknowledged before me this _j5_ day of (. 20 Ig by wme i OR 39e- 0t 53 H. NATHAN MEISTER MY COMMIS':ION #FF1 SW25 EXPIRES November 16. 2018 Who Is personally known to me Ificedon produced: s J Nwary b'Ipnatue N1 LINHTED POWER OF ATTORNEY Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford, Seminole County, Winter Springs Date: I hereby name and appoint: !'trldA W Oki I#,1 \`S ay?o )4t; t OUbin& 9freS an agent of. YAPI-1- \ '%AdUVN S CMA 'S-S M S Namc of Company) to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things necessary to this appointment for (check only one option): 0' The specific permit and application for work located at: V / (Street Address) Expiration Date for This Limited Power of Attorney: la% 31 I1 License Holder Name:Cr • 12 0.k PX State License Number: Signature of License 11 STATE OF FLORIDA COUNTY OF 5CM1 ot The foregoing instrument was acknowledged before me this. 200 , by 1-'%OJSI2 C'T-• (CIX ky- to me or o who has produced identification and who did (di Notary Seal H. NATHAN ME" f MY COMMISSION #FF168625a.: i•B EXPIRES November 16, 2018 07) 388-0153 FlorldallotaryService.com Rev. 08.12) Print or type name day of , who is &15ersonally known Notary Public - State of F106 CommissionNo. MdXAD My Commission Expires: a .I >01T as pe pLopeny Record Card R Parcel: 18-20-31-505-0000-0210 ary o,=ooiwrivr Property Address: 110 BELGIAN WAY SANFORD, FL 32773 Parcel Information rValue Summary Parcel 18-20-31-505-0000.0210 Owner(s) MICHAELIS, ROBERT - Tenancy by Entirety MICHAELIS, NANCY J - Tenancy by Entirety Property Address 110 BELGIAN WAY SANFORD, FL 32773 Mailing 110 BELGIAN WAY SANFORD, FL 32773 Subdivision Name BAKERS CROSSING PHASE 1 Tax District Si-SANFORD DOR Use Code 01-SINGLE FAMILY Exemptions I 00-HOMESTEAD(2004) 60 60 60 60 60 6( U) f` 2 2 2 3 33 60 62.62 7 - ef_LGIAN WAY , 60 60 55. Legal Description LOT 21 BAKERS CROSSING PH 1 PB 60 PGS 27 - 29 Taxes 2018 Working Values 2017 Certified Values Valuation Method Cost/Market Cost/Market Number of Buildings 1 1 Depreciated Bldg Value 149,942 S137,408 Depreciated EXFT Value 11,253 S11,769 Land Value (Market) 37,000 34,000 Land Value Ag Just/Market Value •' 198.195 183,177 Portability Adj Save Our Homes Adj 70,712 58,316 Amendment 1 Adj 0 P&G Adj 0 0 Assessed Value 1 $127,483 1$124,561 Tax Amount wRhout SOH: $2,700.OD 2017 Tax Bill Amount $1,589.00 Tax Estimator Save Our Homes Savings: $1,111.00 Does NOT INCLUDE Non Ad Valorem Assessments Taxing Authority Assessment Value Exempt Values Taxable Value County General Fund, 127,403 50,000 77,483 Schools 127,483 25,000 102,483 City Sanford 127,483 50,000 S77,483 SJWM(Saint Johns Water Management) 127,483 50,000 77,483 County Bonds 127,483 50,000 77,483 Sales Description Date Book Page Amount Qualified Vac/Imp QUIT CLAIM DEED 4/1/2017 08913 1328 100 No Improved WARRANTY DEED 3/1/2003 04825 1222 164,400 Yes Improved WARRANTY DEED 5/1/2001 04087 1769 24,500 Yes Vacant And comperaw Seal" Land Method Frontage Depth Units Units Price Land Value LOT 1 I S37,000.00 1$37,000 Building Information Is Bed/Bath count incorrect? Click Here. d I Description I Year Built Fixtures Bed Bath Base Area Total SF Living SF Ext Wall Adj Value Repl Value Appendages Actual/Effective Baxter Windows B Boors Energy Efficient Windows Et Doors 102 Drennen Rd. Suite B11 Fs B12 CGC: 1522010 Office: 407-930-1599 Orlando, Ft. 32806 www.BaxterWindows.com Site Address: /to To Whom It May Concern: 3o 3 The Windows referenced for installation with the attached building permit paperwork all comply with current Energy Star requirements and building codes; 1. According to FBC, Section 5, June 30, 2017 and subsequent. 2. Requirements per 2017 FBC Energy Conservation R503.1.1.1, Table R402.1.2 with U-Factor maximum of 0.40 and SHGC maximum of 0.25 David G. Baxter, License Holder Baxter Windows LLC 102 Drennen Rd, Suite B11 Orlando FI 32806 407-930-1599 RECORD COPY City of Sanford Building and Fire Prevention Product Approval Specification Form Sulcoti Permit # # 1 8- 3 6 4 9 ANFCRp Project Location Address As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the information and product approval number(s) on the building components listed below if they are to be utilized on the construction project for which you are applying for a building permit. We recommend that you contact your local product supplier should you not know the product approval number for any of the applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product Approval can be obtained at www.floridabuildina.ora. The following information must be available on the jobsite for inspections: 1. This entire product approval form 2. A copy of the manufacturer's installation details and requirements for each product. Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 1. Exterior Doors Swinging Sliding DIVISION Sectional Roll Up LICENSE TO PROCEED WITH HE WORK AND NOT AS Automatic MINER AUTH THF TFQHNICAL Other CODES, NOR SHALL ISSUANC OF A PERMIT PREVENT 2. Windows DATE ER PLANS Single Hung CONSTRUCTION OR VIOLA IONS OF THIS CODE Horizontal Slider Casement Double Hun S1rft n k0ln S 0 51 -L3 Fixed Awning Pass Through Projected Mullions Wind Breaker Dual Action Other June 2014 Category / Subcategory Manufacturer Product Description Florida Approval # including decimal 3. Panel Walls Siding Soffits Storefronts Curtain Walls Wall Louver Glass block Membrane Greenhouse E.P.S Composite Panels Other 4. Roofing Products Asphalt Shingles Underla ments Roofing Fasteners Nonstructural Metal Roofing Wood Shakes and Shingles Roofing tiles Roofing Insulation Waterproofing Built up roofing System Modified Bitumen Single Ply Roof Systems Roofinq slate Cements/ Adhesives / Coating Liquid Applied Roofing Systems Roof Tile adhesive Spray Applied Polyurethane Roofing E.P.S. Roof Panels Roof Vents Other June 2014 M& Category / Subcategory Manufacturer Product Description Florida Approval # include decimal 5. Shutters Accordion Bahama Colonial Roll u Equipment Other 6. Skylights Skylights Other 7. Structural Components Wood Connectors / Anchors Truss Plates Engineered Lumber Railing Coolers/Freezers Concrete Admixtures Precast Lintels Insulation Forms Plastics Deck / Roof Wall Prefab Sheds Other S. New Exterior Envelope Products Applicant's Signature Applicant's Name h d -* VW i Please Print) June 2014 WINDOW MEASUREMENTS NAME: Michaelis it OF STORIES: DATE: TYPE OF CONSTRUCTION: CB/Stucco Finish TYPE OF WINDOWS: SIZE(WxH) MDL LE OBS TP GRI ATTERN L/H FS SQ' U.1 351/4 70 3/8 TF V 00, 17.227 105.625 351/4 701/2 TF V 17.258 105.750 351/4 701/2 17.258 105.750 351/4 613/8 15.024 96.625 513/8 611/2 21.941 112.375 35 3/8 611/2 15.108 96.875 351/8 613/8 14.971 96.500 511/4 613/8 21.844 112.625 513/8 613/8 21.897 112.750 351/8 611/4 14.940 96.375 351/8 611/2 15.001 96.625 Total 192.469 OnlyTP 34.48S U173 I U193 I U1101 I U1 10 I U11130 I U1131+ OF WINDOWS Iof Drawing Screwed in: Stucco: I 1 11 copyright©H. Nathan Meister, 2012 Obscured Mulls Tempered 2 Brick: 6/27/2018 ' I • ' . Florida Building Code Online Business & Professional Regulation rem r®ar® BCIS Mpme I Log In I user "[Stratton I Mot Topes I Submit Surcharge I Slats a Facts I RrblimUoni I Contad US I SCIS Ale Map I links kaRhrdProductApproval USER: Rr611c then RvOud Aeerwal Menu > praAud ar Aoollouon Srarcfi > Apoloum Urt > Appllollon Oahu FL # FL5167-R27 Application Type Revision Code Version 2017 Application Status Approved Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Simonton/Ply Gem Windows Address/Phone/Email 3948 Townsfair Way, Suite 200 Suite 200 Columbus, OH 43219 614)532-3596 luanne.harris@plygem.com Authorized Signature Luanne Harris luanne.harris@plygem.com Technical Representative Luanne Harris Address/Phone/Email 3948 Townsfair Way Suite 200 Columbus, OH 43219 614)532-3596 luanne.harrls@slmonton.com Quality Assurance Representative AAMA Address/Phone/Email 1827 Walden Office Square Suite 550 Schaumburg, IL 60173 847) 303-5664 webmaster@aamanet.org Category Windows Subcategory Double Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By American Architectural Manufacturers Association Referenced Standard and Year (of Standard) Standard AAMA 450 AAMA/WDMA/CSA 101/I.S.2 A440 AAMA/WDMA/CSA 101/I.S.2 A440 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 04/13/2018 Date Validated 04/24/2018 Date Pending FBC Approval Date Approved 05/02/2018 https:// loridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXOwtDgtZMlu87gOKmCtAC9nEO%2bU7riJo6lJsUK4xcc-5eOw6i nQ%3d%3d Year 2010 2005 2008 1/5 6127/2018 Florida Building Code Online Other: 44x63 (+/-25 PSF), 46x84 (+/-25 PSF), 36x72 (+/-30 PSF), FL5167 R27 C CAC 43-35 DH 5201 R35 frjLLlldf 4Bx80 (+/-35 PSF), 52x71 (+/-35 PSF) Quality Assurance Contract Expiration Date 01/24/2021 Installation Instructions FL5167 R27 II IN0105 43-35 DH 2X.pd( FL5167 R27 II IN056843 43-35 DH 1X.Qd( Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5167 R27 AE EvalRenort-IND568-R3.odf Created by Independent Third Party: Yes 5167.12 43-35 (TWo-Step Sill) and 43-50 (Three- 6100 VantagePointe, Asure, PerfeXion Silver Vinyl Double Hung Twin with Step Sill) Transom Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL5167 R27 C CAC 43-35 DH Twin w Transom 73x111 R35 (=),rjW FL5167 R27 C CAC 43-50 DH AAMA 450 R35 73x111 fr.=LRdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure: +35/-35 01/24/2021 Other: 73x111 Installation Instructions FL5167 R27 li IN053S 43-3SO43-50 DH Twin with Transom 2X.W Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 51.67.13 43-40 and 43-45 Reflections SOSO, Reflections 5300, 6100 VantagePointe, Perfexion Gold Vinyl Double Hung Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL5167 R27 C CAC 43-40 DH 32x62 RSO.I& Approved for use outside HVHZ: Yes FL5167 R27 C CAC 43-40 DH 36x63 R45.pdj Impact Resistant: No FL5167 R27 C CAC 43-40 DH 36x72 R30.Rdf Design Pressure: N/A FL5167 R27 C LAC 43-40 DH 3604 R50.12df Other: 36x72 (-14-30 PSF), 52x71 (a•/-35 PSF), 48x80 (+/-35 PSF), FL5167 R27 C CAC 43-40 DH 44x63 R PG45.U& 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), 32x62 (+/-50 PSF), 36x74 FL5167 R27 C CAC 43-40 DH 44x63 R35.Rdj 50 PSF) FL5167 R27 C CAC 43-40 DH 4Bx80 R35.odf FL5167 R27 C CAC 43-40 DH 5201 R35.odf FL5167 R27 C LAG 43-45 DH 52x71 R35.pdf FL5167 R27 C CAC 43-45 waiver to 43-40.wg Quality Assurance Contract Expiration Date 09/12/2021 Installation Instructions FL5167 R27 II IN0432b 43-40 43-45 DH 2X.a& FL5167 R27 II IN0434-R6 43-41) 43.45 DH 1X.pdj Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5167 R27 AE EvalRenort-INO434-R6.odf Created by Independent Third Party: Yes 5167.14 43-50 (Three -Step Sill) 6100 VantagePointe, Asure, PerfeXion Silver Vinyl Double Hung Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL5167 R27 C CAC 43-50 DH 32x62 R50 lSXLLW Approved for use outside HVHZ: Yes FL5167 R27 C CAC 43-50 DH 36x63 R45 fsXU,Cdi Impact Resistant: No FL5167 R27 C LAC 43-SO DH 36x74 R50 (=LRjff Design Pressure: N/A FL5167 R27 C LAC 43-50 DH 44x63 R4S (SA),pdj Other: 52x71 (+/-3S PSF), 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), FL5167 R27 C CAC 43-SO DH S201 R35 (=),I cif 32x62 (+/-SO PSF), 36x74 (+/-50 PSF) Quality Assurance Contract Expiration Date O1/25/2021 Installation Instructions FL5167 R27 II IN0432 43-50 DH 2X.RQ( FL5167 R27 11 IN0569-R3 43-SO DH 1X.pdf Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports FL5167 R27 AE EvalRenort-IND569-R3.W Created by Independent Third Party: Yes 5167.15 75-75, 75-09, 07-75, 07-09, 07-10 and Reflections 5500, Generations, Impressions 9800, 6500 VantagePointe, 07-20 PerfeXion Platinum Vinyl Double Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5167 R27 C CAC 07-09-10-20 and 08-09-10-20 Waiver.Rd[ Approved for use outside HVHZ: Yes FL5167 R27 C CAC 07-10 07-20 to 07-09 Walver.pd[ Impact Resistant: No FL5167 R27 C CAC 07-75 DH 48x80 R PG35.p& Design Pressure: N/A FL5167 R27 C CAC 07-75 DH 53x74 R PG30.gdj Other: 48x80 (+/-25 PSF), 53x74 (+/-30 PSF), 48x80 (+/-35 PSF), FL5167 R27 C CAC 07-75 DH S3x80 R PG40.D& 52x71 (+/-35 PSF), 53x80 (+/-40 PSF), 36x63 (+/-SO PSF), 36x74 FL5167 R27 C CAC 07-75 waiver to 07-09.12dj SO PSF), 36x72 (+/-SS) FL5167 R27 C GAG 75-75 DH 36x63 R PGSO.aW FL5167 R27 C CAC 75-75 DH 3602 R PGSS.pd[ FL5167 R27 C CAC 75-75 DH 36x74 LCSO.Rdj FL5167 R27 C CAC 75-75 DH 48x80 LC PG25.odf FL5167 R27 C CAC 75-75 DH S201 R PG35.W FL5167 R27 C CAC ACP-05 SIM 07-75 DH HS PW frame 07-09.pdj FL5167 R27 C CAC ACP-05 SIM 75-75, 07-09, 07-7s,_07-09, 75-10. 75-20 DH frame.pW Quality Assurance Contract Expiration Date 03/25/2020 Installation Instructions FL5167 R27 II IND113 75-75 75-09 07-75 07-09 07.10 07-20 DH Z&Px FL5167 R27 II IN0132-Rll 75-75 75-09 07-75 D7-09 07-10 07.20 DH hitps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXowIDgtZMlu87gOKmCtAC9nEO%2bU7riJo6lJsUK4xcc5eOw61nQ%3d%3d 4/5 Validator / Operations Administrator) Simonton Windows 1 Cochrane Dr. Pennsboro, WV 26415 Attn: Tina Seese AAMA CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory. SPECIFICATION RECORD OF PRODUCT TESTED AAMAIWDMA/CSA 101/I.S.2/A440-08 R-PG50'-813x1575 (32x62)-H COMPANY AND CODE CPD NO. SERIES MODEL & PRODUCT MAXIMUM SIZE TESTEDDESCRIPTION Simonton Windows 43-40 DH FRAME SASH 10390 PVC)(X/X)(OG)(INS GL) 813 mm x 1575 mrn 737 mm x 778 mmCode: SIM TILT)(ASTM) 2'8" x 5'2") 2'5" x 21711) This Certification will expire January 30, 2022 (extended from January 30, 2017 per AAMA 103-15) and requires validation until then by continued listing in the current AAMA Certified Products Directory. Product Tested and Reported by: Architectural Testing, Inc. Report No.: C5630.01-109-47 Date of Report: February 15, 2013 JGS/JTS ACP-04 (Rev.6/16) Evaluated for Certification: August 12, 2016 4te rdLaboratories, Inc. Authorized for Certification: August 12, 2016 T Ameri Architectural Manufacturers Association URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 1N0434-R6 December 1, 2017 Product Description: Double Hung Vinyl Window Series 43-40 / 43-45, X/X configuration Manufacturer: Simonton Windows, 1 Cochrane Ave., Pennsboro, WV Statement of Compliance: This report evaluates the above -listed product per the requirements ofFAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 61h Edition (2017) Florida Building Code outside the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Installation drawing IN0434-R6, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports C2276.01-109-47, C3522.01-501-47, C3526.01-501-47, C5630.01-109-47, and D2310.01-501-47 by Architectural Testing, Inc, with testing performed: AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support IN0434-R6, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to installation drawing IN0434-R6. Limitations of Use: This product: May be used in the configurations and product sizes as indicated in IN0434-R6 Is non -impact and requires the use of impact protective devices in windborne debris regions May not be used in the High Velocity Hurricane Zone Requires white PVC extrusions in accordance with the product testing, IN0434-R6, and with current listing as an AAMA Certified Profile Licensee under AAMA 303 Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Simonton Windows or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. P pRE W1VE ' VP: SF.y. Lucas Z. vTurner J No 56201 2017-12-01 11:05+19:00 a ; = 12/1/2017 STATE OF : Qj 0 tV Lucas A. Turner, P.E. O A t QPCN.•,, FL PE #58201 NSS,ONA MODEL DESIGNATION: Stmonlon Double Hung Series 43-40 / 43-45 Vents window MA)aMUM OVERALL NOMINAL SILL• See Size Chart DESIGN PRESSURE RATIN •: See Sze Chart USABLE CONFIGURATIONS: KX r N RAI O SCRIPTION: The head. sill. and side jambs ore extruded PVC. The wall thickness through which the anchor screw penetrates is o minimum of 0.070' SIZE CHARF OVERALL SIZE OP RATING111DTHIHEIEVlf 36' 72' 330 PSF a4' 36' 335 PSFae' 10' 52' 71, M. 63' 315 PSF K4 63' 32' F2 i50 PSF 36' 1 7a' Rv NO P.E. SEAL REWIRED INSTALLATION SUPPORTED BY AAMA TEST REPORTS 1 a 1 .mm Iw MCI I.st. rrOTL l .min IrafC7 la a la - - SILICONE 2K BUC` • CAULK 9UCONC CAULK 1 /, YAX. SIaM 7K BUCK: SILICONE CAULK 1/a' MAIL saw HEAD s K 2 11r UlN vow SCREW wTH I-W MIN. EMBEDMENT INTO WOOD MIN. EDGE DIST.. SEE NOTES Lk SILICONE CAULK SILICONE CAULK SUCONECAULK 2x BUCK SILL Qv - JAMB NOTES, I. This mstallauon has been evaluated for use us tactoons adhering to the Fionda Building Coda and where pretture requirements as determined by ASCE 7 Mmarium Design leads for Buildings and Other Structures do not exceed the design pressure ratings herein, lei use outside theH.VA.Z. 2. All Inseriol and exlerhw perimeter surfaces of the windovrmust be caul ell. 3. Ambors shall be as specified and spaced as shown. Anchw embedment to base material shall be beyond wall dressing or stucco and imowoud. K. The responsibility for seleNon of Simonson products to meet any applicable local laws, building coda, Ordinances, or other safety requirements rests soletV wits the andlltect, budding owner, w contractor. S. Shim* are optional. Max. shim stall Is 1/4'. 6 Wood bucks (by others) muss be engineered and anchored properly to transfer loads toshe structure. 7. Screws should be aminimum of 3/4' from the edge of the wood. B. When used in areas requiring Impact proteetion, this DrodU" REWIRES the use of approved impact resistant shutters or other external protection 9. Flashing should be applied using the ASTM E 2112 method appropriate for the opening Into which the window Is being Installed. IO Installation screws must be at Trost 3P4* from The edge of the wend.. 11. Clazing shallcomply wlth ASTM E 1300. 12 Use 100%Pure sihtone caulk compliant wish AAMA 000 Section I • Sealant Specificallons for use with Archltequral Fenestration Roducts. Make sure surfata are completely free from all old caulk, damaged wood, wood Fibers. grease, col dirt, ruts, mold or similar contaminants Vacuum and clean opening surfaces completely. A fully primed surface Is recommended, bus not rtquived. Cleaning of all surfacesshould bedone the same day ofwhich The silicone caulk is to applied. Fw more details visht Smionton.Com 13. Caulk application. recommended air and surface temperatures at the dine of application are to be between aD and 90 degrees F Insure all contact surfaces are dean and ciry hncludrnp the new whndowls) Use a backer rod on all joints >3/4* deep and/or wider Than 1/4•. Finished soul joint should be a minimum of 3/$' deep and make full onew w ctactwishboththeninwdoand susicturalopeningsurfaces. Silicone FOUR, should be Forced Intoloint owcompressed to assure full contact on both surfaces and to expel aria air pools. Ittrtr N G ten rrr.a Yei raaye. Owiwwrir Irrrwee / r i .vn Mwtw) N N)w nyra Y Ili w wN MIIw yr.... mi,...h.. IV „ wednr M W rrgawl wi w grWY 1 a'eArae \,twhr MY nr1YNrrwsarY,[.e w •lyre Y o ww w V 1MIarw slMNmhovawn rhsw . Dedir war r onlw nrahn wtot not e innlae ri r M IMFsw Ax n nT h N 1 n1sww,.rr - `wave, tee. .ia e wv .To ... .a•w .a-u m L.m! MODEL OESIGNATON SmmmR Double Hung Swim 13•10 / 10+5Vln)1VAndw 1zZ •a MAXIMUM OVERALL NOMINAL SM See sift E].0 J`\9. 1GENa'•., 7)/01/)0+7 2 r 11• VJCNRNE V.[ •opmw N DESIGN PRESSURE RATING. Lucas Sam FL A SeeSlraC1un - R PE / ME 0 7umer70FNERCNcmE[M"c • USABLE CONFIGURATIONS X 2017.12-01 soi i c COASULIIIG.IIC ' wam ewN z 11,05+19.00 '9t, aTAra of i1tr: 12-.OA / jAaAAAx, GENERAL DE9CRP110N. The hoed. NI, mid $I* pmbs mo extruded PVC The "I IMUImaaONA N\?yC NO „, 941-330L .5 J Duough vtoch Dw r exhor wlpe11a11abes0a -U. DI 0 1/7. d v uOERgR SASH 1RAIX kHLT5A54 RTo q J AUIW NAx DVEPMiFRA1E INDIN -••I J SIZL• CHART OVERALL SIZE DP RATING WIDTH W HEIGHTK 06' 77 19D PSF 11• or 175 PSF IB• a0' Sr 71, ae' ar tAS PSF 11• ELT 67 50 PSF JB' 7A• 6u057AA1E DY OVER$ SKCGNIE CAULK 6EE NOTES taa it Z 81E4T i SUEOr/E ROTES 54sa le SHEETtY'NAILSMN HEAD 1 MIN EMBED' SEE TITLE 1, SLEET 2 Sa1CONE CAULK LAL a18STRATE SEE NOICSI$ US aY DINERS SNFE12 lY• t1AK eWN SLICONE CAW( INSTALLATION FABTFNERS tN•MAIL BALM aRC011E CAW( SCE NOTES 159 1e SEE I ISLE I, SIEE72 SECNDTESIla to bNEET2 SHEET 2 IIR1 EDGE 001. SUBSTRATES11YOTNERS7 r SEE IAIDE 1. SHEET) SILL mL1CWEGVAII f BEE NOTES IS& le. SNEER JAMB eww.sr I. 1. w uwoN.w a.e1M Ai\1ftJdID1 C] a . YLIa rro SIMONTON' Had \ V iN I! MODEL NA)aNWA OVERALnLNOMINAL SRE n l^b Hung 6odiy a117 Vinyl Window J9;1 OFUEI ';4,pyry 1 2C17F •i'as LUUS A TUPNCR. PE. DESIGN PRESSURE RATG• Saw Chad Sa701 'yP!. R PE I illaa e IUNNLN I, LULLWHU a USABLE CONFIGURATIONS. INC.NS. % '9; Oraii Ov 'O4i2 (COA / 29779) X 1233 JA6NA AYG GENERAL DESCRPnoN. The limit, sit. and silo jdrOs rw extruded PVC Thu well IhWlosa 1'ryBrONlnt.rr.. N IN9aO 1J Pin-t-t57 tlwplpli wavdl tie onclls avow I1pMnita • o mNmum d 0test. TABLE I. INSTALLATION rA sTEnCils tAE E JNG NOTES: 1. This Installation has been evaluated for use in locations adheringto the Florida WildingCode outside theHVH7, and .mere pressure requirements as determinedby ASCE7Minimum Design Loadsfor Buildings and Other Structures do nos exceed the design pressure mdrigs hvein. 2. For anchorage requirements in various substrates see Table 1. A minimum distance of 3• shall be maintained between any two installation fasteners. 3. All interior and exterior perimeter surfaces of the window, must be caulked. a. Mchos type. size. spacing, embedment. and edge distance shall be as specified In these drawings. S. Anchor embedment to substrate shall be beyond wall dressing or stucco. For masonry openingswith woodbucks lessthan 1.1/2' thick, embedment shall bebeyond woodbucks, d used, and Into masonry aubacram. Wood bucks with masonry are optional. 6 Wood or masonry openings, bucks. and buck fasteners• by others, shall be propertydesgned and installed to transfer wind loads to the structure. 7. The respon"ItIlity for selection of Simonton products to meet arty applicable local laws• building codes, ordinances, or other safety requirements rests solely withthe architect, building Owner. or contract". a. Shims are required where gaps of greater than 1/1 Vexistbetween opening and frame. Max. shim stack is 1/40, Shims shall bebadbearing andcapableof transferring loadstothe substrate. 0. When used in areas requiring Impact protection• this product REQUIRES the use of approved impact resistam shutters orother internalprotection. 10. Sealing and gashing by others should be applied using the ASTM E 2112 methodology appropriate for the opening into which the product is being InsialkD Overall voter penetration resistance of the installed product is not addressed in this drawing and is rim responsrhilrry of others. 11. Glazing shall complywIh ASTM E 1300 Oa. 12. All fasteners penetrating into pressuretreated wood shall becapableof prewriftnp corrosion due to reactionwith pressuretreatment chemicals. Any disshnbarmaterials That comeImo contact stall be protected to prevent reactions In accordance with code requirements. 13. A Wind bad duration factor Cd . 1.6 wasused Mr the amlysls of wNd %c- only 14. Products shall be constructed as specilled In test reports 02310.01.501 J7. C3526.01.501•47 andC3522.01.501 •a7 by AtchhecturalTesting, Inc - Springdale. PA andC5630.01.109 47and C2276. 01.109-47 by Architectural Testing, Inc - York, PA. 15. Use 100%pit, silicone caulk compliant with AAMA 800 Section I - Sealant Specifncallons for use with Architectural Fenlesirabon Products. Make sure surfaces are completely free from all old caulk, damaged wood, wood fibers, grease, all din, rust, meld or similar contaminants. Vacuum and clean opening surfaces completely A fully primed surface is recommended• but not required. Cleaning of all surfaces should be done the same day of which the silicone caulk is to applied. For more details visit Smonton com. 16. Caulkapplication: recommended air and surface temperatures at The time ofapplication are to be between 40 and 90 degrees F. Insure NI contactsurfaces are clean and dry Includingthe new wndowts). Use a backer rod on all joints a3/a' deep and/or wider than 1/4'. Finished caulk joint should be a mlmmum of 3/b' deep and make full contact With both the newwrdw and structural opening surfaces. Silicone caulk should be forced Into joint or compressed to assure full contact on both surfaces and to expel any air packets. SIMONTON- a Naafi a r. r rw. ew rr .Arl.•.r Iit.i.V IMI! e.w,.w.ee...e..w....--wax. oe.. .,tie w. r.W.wsrr w.ww Irn.v« n •.ewe etas m e.1 YwewrWer Yrw.wp. xxsar CbM, rues wlwsooirazlesla ettoanrK i. c wain O irwrtrr.en.w4tnwO SUBSTRAiC 7YPC INC•10R TiPE NH. _YOCD IN A CONfliClE 2 M^d uN 3 16' Rw 1,V'C0N 7-t 2' 1 t •a' 0 u1171W,r 1 Y AC'CO Nl l.0 J/lam Rw IAPWN C 7 pss RN N W90 3/16 RW TAPCpN 1-J/a 3/a. ER M.D O7^ f tJWOOD SCREW I J/a' 3/•' y IG GAL 000G, taw L 1 f0- ta w 'Ems S• Lr-ORIWNG SCREW RIII TNRr,JI 1/7' F l a ALUM. a- WN. 4 1 G - N rUll TNRC-0 1/2 16YWN