HomeMy WebLinkAbout261 Venetian Bay Cir - BR18-002881 - SOLARifCITY OF
S/ll 1 ORD
FIRE DEPARTMENT
PX' Building & Fire Prevention Division
PERMIT APPLICATION
Application No: It 8`CP88
Documented Construction Value: $ 21,800
Job Address: 261 Venetian Bay Circle, Sanford FL 32771 Historic District: Yes Noz
Parcel ID: 23-19-30-502-0000-0920 ResidentialD Commercial
Type of Work: New Addition Alteration Repair Demo Change of Use Move
Description of Work: Install New 6.49KW Photovoltaic Solar Electric
Plan Review Contact Person: Jim Smith Title: Permit Technician
Phone:813-230-1287 Fax: Email: limcsmith007CCgmail .com Property
Owner Information Name
Freeman, Sarah & George Phone: 407-474-3830 Street:
261 Venetian Bay Circle Resident of property? : yes City,
State Zip: Sanford FL 32771 Contractor
Information Name
Gulf Electrical Service LLC Phone: 813-230-1287 Street:
4897 W. Waters Avenue Suite E Fax: City,
State Zip: Tampa FL 33634 State License No.: EC13001255 Name:
Street:
City,
St, Zip: Bonding
Company: Address:
Architect/
Engineer Information Phone:
Fax:
E-
mail: Mortgage
Lender: Address:
WARNING
TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Application
is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced
prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in
this jurisdiction. 1 understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces,
boilers, heaters, tanks, and air conditioners, etc. FBC
105.3 Shall be inscribed with the date of application and the code in effect as of that date: 611 Edition (2017) Florida Building Code Revised:
January I, 2018 Permit Application
NOTICE: In addition'to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records of this county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance of permit is verification that 1 will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ]CC Valuation Table in effect at the time the permit is issued, in
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
el-cih l 6-22-18
Signature of Owner/Agem Date
Sarah Freeman
Print Owner/Agent's Name
Rkxl;r_ Da-, " k A rs_o4_&-22-18
Signature of Notary -State of Florida Date
a , bz-) &\ 6-22-I8
Signatu o ontra or/ gent Date
Daniel Yates
Print Contractor/Agent's Name
can . crho a d a _ 6-22-18
Signature of Notary -State of Florida Date
Owner/Agent is Personally Known to Me or Contractor/Agent isPersonally Known to Me or 19, Produced
ID _ Type of ID Fl_1pMProduced ID Type of 1D BELOW IS
FOR OFFICE USE ONLY Permits Required:
Building Electrical Mechanical Plumbing Gas Roof Construction Type:
Occupancy Use: Total Sq
Ft of Bldg: Flood Zone:
Min. Occupancy
Load: # of Stories: New Construction:
Electric - # of Amps Fire Sprinkler
Permit: Yes No # of Heads d,.t8- .
vi APPROVALS: ZO1NG: UTILITIES: ENGINEERING: FIRE:
Plumbing - # of
Fixtures Fire Alarm
Permit: Yes No WASTE WATER:
BUILDING: 5F - -
s COMMENTS: OK &
V /ssjoly// Su/a, oA eyoA " 4 o;,*,, %..e Revised: January
I, 2018 Permit Application
6/17/201 s " SCPA Parcel View: 23-19-30-502-0000-0920 AAMINUMCFA
PAPP
ME6 GCW40La
oo W".. nnna P—
MlLdr y Record Card Parcel:
23-19.30.502-0000-0920 Property
Address: 261 VENETIAN BAY CIR SANFORD, FL 32771 Parcel
Information Parcel
23-19-30-502-0000-0920 Owner(
s) FREEMAN, GEORGE M FREEMAN,
SARAH B Property
Address 261 VENETIAN BAY CIR SANFORD, FL 32771 Mailing
261 VENETIAN BAY CIR SANFORD, FL 32771 Subdivision
Name VENETIAN BAY Tax
District S7-SANFORD DOR
Use Code 01-SINGLE FAMILY Exemptions
00-HOMESTEAD(2005) 00
50.00 60.00 P
0
m
CD
Z
w
cn 0
r-
o CD
N
50.
00 50.00 35.00 ro Seminole
Countv GIS htip://
parceidetailscpafl.org/ParcelDetailinfo.aspx?P]D=23193050200000920 1/2
General Contracting • Energy Management
Uc. # CRC1327012 • www.EHSFL.com
844) 778-8810 • service@ehsfl.comHS097WestWatersAve., (Suite E) • Tampa, FL 33634
Efficient Home Services
Buyers Name(s) Sarah Freeman Date 6/6/2018
Address 261 Venetian bay cir
city Sandford state FL Zip Code32771 County USA
Home Phone 4074743830
Email
We hereby submit specifications:
Cell Phone
com
PROPOSAL — CONTRACT
22 panels 6.49kw
We propose to furnish material and labor — complete in accordance with the above specifications for the sum of:
21,821 Dollars
with payments to be made as follows: Service 6059.
Any afteration or deviation from above specifications, involving extra costs will be
executed only upon written order, and will become an extra charge over and above the
estimate. All agreements contingent upon strikes, accidents, or delays beyond our
control.
At ed A ent for Efficient Nome Services
Note: This proposal maybe wftravm by us 9not awepted within 3 days
BUYERS RIGHT TO CANCEL `This is a home solicitation sale, and if you do not want the goods or services, you may cancel this agreement by providing
written notice to the seller in person, by telegram or by mail. This notice must indicate that you do not want the goods or services and must be delivered or
postmarked before midnight of the third business day after you sign this agreement. This notice must be mailed to. EFFICIENT HOME SERVICES, 4897
West Waters Ave., Suite E., Tampa, FL 33634. If you cancel this agreement, the seller may not keep all or part of any cash down payment' Florida Statute
713.001-713.37: According to Construction Lien Laws, those who work on your property or provide materials and services are not paid in full have a right to
enforce their claim for payment against your property. This claim is known as a Construction Lien. Ifyourcontractor fails to pay subcontractors or material
suppliers, those who are owed money may look to your property for payment, even ifyou paid your contractor in full. If you fail to your contractor, your
contractor may also have a right to file a lien on your property. This means if a lien is filed on your property, this property could be sold against your will to
pay for labor, materials or other services that your contractor may have failed to pay. To protect yourself, you can require your contractor to furnish you with a
written lien release after project completion and monies paid to the contractor. If the contractor provided you with a'Notice to Owner', this notice must be
posted on your property, it this action is applicable.
ACCEPTANCE OF PROPOSAL
By signing this agreement, customer hereby authorizes Efficient Home Services to apply for and sign for permit on the customer's behalf. This authorization
is only valid for permits obtained relevant to contracted work and unfit final inspection occurs. The above prices, specifications and conditions are satisfactory
and are hereby accepted. You are authorized to do the work as specified. Payments will be made as outlined above. All our installations include (1) year of
free service. By signing this contract, customer also expressly acknowledges and agrees that (1) this contract constitutes the entire agreement of the parties
hereto with respect to its subject matter and supersedes all prior and contemporaneous representations, proposals, discussions, and communications,
whether oral or in writing: and (II) no other promise or agreement of any kind has been made to or with the customer by any person or entity to causethe
customer to execute this document. This contract may be modified only in writing and shall be enforceable in accordance with its terms when signed by each
of the parties hereto. For additional terms and conditions see back page. ,QL' 29/
Date of Acceptance: 6/6/2018 Signature
J
Signature
N GRANT MALOYr SEMINOLE COUNTY
CLERK OF CIRCUIT COURT 6 COMPTROLLER
BK 9162 Ps 12 QP9s)
Permit Number CLERK'S : 2018074000
Tax Folio/Parcel ID: 23-19-30-502-0000-0920 RECORDED 06/27/2018 10:23::25 All
RECORDING FEES $10.00
NOTICE OF COMMENCEMENT RECORDED BY hdevore
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter
713, Florida Statutes, the followingInformation is provided in this Notice of Commencement: O : t1. Description of property: (legal description of property, and street address if available) LOT 92 VENETIAN BAY PB 63 PGS P `, .• ; ,; fa '
84 - 88
261 Venetian Bay Cirle, Sanford FL 32771
2. General description of
3.Owner Information:
Install New
a. Name and address: rreeman, saran oc ueor8e; zo
b. Phone number: 407-474-3830
c. Name and address offee simple titleholder (Ifother than owner):
ki
4.Contractor: Gulf Electrical Service LLC; 4897 W. Waters Avenue Suite E, Tampa FL 33634
v
a. Name and address:
b. Phone number: 844-778-8810
5. Surety:
a. Name and address: N/A
b. Amount of bond 5:
6. Lender:
a. Name and address: N/A
c. Phone number:
b. Phone number:
7. Persons within the State ofFlorida designated by Owner upon whom notices or other documents may be served as provided by Section
713.130)(07, Florida Statutes:
a. Name and address: N/A
b. Phone number:
8. In addition to himself, owner designates the following person(s) to receive a copy ofthe Lienor's Notice as provided In Section 713.13(1)
b), Florida Statutes:
a. Name and address: N/A
b. Phone number.
9. The expiration dateofthe notice of commencement is one (1) year from the dateofrecording unless a different date is specified
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE
OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION
713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVMENTS TO YOUR
PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE
THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING IWORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
lGg- _70M_e07 Owner
Signature of Owner or Owners Authorized Officer/Director/Partner/Manager Signatory'sTitle/Office
STATE OF FLORIDA, COUNTY 6.
The foregoing Instrument was acknowlwdged before me this 6th dayof June 20 18
by Sarah Freeman (name of person) as Owner (type of authority: e.g., officer, trustee, attorney In fact)
for
who has produced FL DMV
allotary Public State of Florida
James C SmithMyCortimissionGG197445
Expires 03118f2022
Document Prepared By.
James Smith 8604 E Sligh Ave
Tampa FL 33610
name of party on behalf of whom Instrument was executed), who Is personally know to me or
as Identification. ,
na re of Notary c
Verification Pursuant to Section 92.525, Florida Statutes
Under penalties ofperjury; Ideclare that I have read the foregoing and
that the facts stated i are true to the best ofmy knowledge and belief
Signature of Natural Pe6on Signing Above
r
LIMITED POWER OF ATTORNEY
Altamonte Springs, Casselberry, Lake Mary, Longwood, Sanford,
Seminole County, Winter Springs
Date: 6/13/2018
I hereby name and appoint: James Smith
an agent of: Gulf Electrical Service LLC
Name of Company)
to be my lawful attorney -in -fact to act for me to apply for, receipt for, sign for and do all things
necessary to this appointment for (check only one option):
KI The specific permit and application for work located at:
261 Venetian Bay Circle, Sanford FL 32771
Street Address)
Expiration Date for This Limited Power of Attorney: 6/13/2019
License Holder Name: Daniel Yates
State License Number: EC130g1255
Signature of License Holder:
STATE OF FLORIDA
COUNTY OF
The foregoing instrument was acknowledged before me this 13th day of June ,
20 18 , by Daniel Yates who is7Q personally known to
me or o who has produced as
identification and who did (did not) take an oath.
Notary Seal)
PATRICIA A NASRALLAH
MY COMMISSION # FF24.1182
EXPIRES June 17.2019
14GI)798-01b3 FlondaNtmrrySorvke corr.
Rev. 08.12)
Signature
Patricia Nasrallah
Print or type name
Notary Public - State of Florida
Commission No. FF241182
My Commission Expires: 6/17/19
RECORD COPY
Install 6.49KW Photovoltaic Solar Electric
Freeman, Sarah & George
261 Venetian Bay Cirle, Sanford FL 32771
407-474-3830
New 6.49KW Photovoltaic Solar Electric
22 SW295 Solar Panels
SE5000H Inverter
Ironridge Roof Mount Rail System
Gulf Electrical Service LLC
Daniel Yates - EC13001255
453 N Dixie Ave, Titusville FL 32796
321) 917-4961
DANIYAT7@aol.com
18-2881
Panels
22 Roof Mounted
Panels (Flush)
A minimum 3'-0"
to be maintained
from any panel to
edge of roof
REVIEWED POR CODE COMPLIANCE
PLANE EXAMINER
l -la ---
DATE
ISSUED SHALL BE CONSTRUED TO BE A
LI 0 PROCEED WITH THE WORK AND NOT AS
ITY TO VIOLATE, CANCEL. ALTER OR SETAOFTHEPROVISIONSOFTHETECHNICALCRSHALLISSUANCEOFAPERMITPREVENT
ILDING OFFICIAL I ROM THEREAFTER
G A CORRECTION OF ERRORS IN PLANS, IL CTION OR VIOLATIONS OF THIS CODE
I
PROPERTY VIEW
@J
2 E
Q OWU
C
F- w
z
t7 r0
N Ew
N
F- v
Q
z 3
O 3
N L
E
9 8 7 6 5 4 3 2
RESIDENTIAL GENERIC STRUCTURAL PLAN. CERTIFY THAT THE SHEETING&FRAMING OF THIS STRUCTURE WILL SAFELY
ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND
W 0 DESIGNED FOR V -200 MPH., 0 Z ULT- NO PLANS ON FILE -EACH PERMIT REQUIRES SIGNED & COMMON SOLAR COMPONENT EXAMPLES SHOWN -
APPEARANCE MAY VARY.
THIS IS ATTESTED TO BY MYIPMENTDEADONiwsORAWINGgTTHEUFPERRIGFIT REANOSEAL FBC 2017 (6"' EDITION) FLORIDA BUILDING CODS. E
3 RISK II, EXPOSURE D. RAISED SEAL PLAN FROM EOR1O.i
IRONRIDGE PV RAIL GENERIC INSTALLATION PLAN
1. THIS 15 A SINGLE SHEET GENERIC STRUCTURAL PLAN. ELECTRICAL PLAN IS
SEPARATELY SEALED DOCUMENT.
2. THIS PLAN OFFERS THREE INSTALLATION METHODS.
a. FRAMING METHOD. SEE DRAWINGS.
b. SHEETING METHOD. SEE DRAWINGS.
C. STANDING SEAM/PBR (PURLIN-BEARING) METAL ROOF. USE
CLAMP/BRACKET OF CHOICE;
ACE. http://www.pmcind.com/aceclamp/
S-5. https://www.s-5.com/products/clamps-brackets/s-5-u-clamps/
https://www.s-5.com/products/clamps-brackets/proteabracket/
3. CONTRACTOR SHALL MAKE CLEAR TO AH1 WHICH INSTALLATION DETAILS
WILL BE USED.
4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE.
5. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY
MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE.
ADJOINING MODULES SHALL SHARE MID CLAMPS. MODULES MAY BE
LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION.
6. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF
FRAMING. SEE ROOF ATTACHMENT SPAN TABLE @ LOWER RIGHT
7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE.
8. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF
ATTACHMENT BY MORE THAN 1'
9. RAILS SHALL ATTACH TO ROOF THRU L-FEET AS SHOWN HEREON. L-FEET
REQUIRE FLASHINGS WHICH CAN BE SF -SO (SELF -FLASHING, SHEETING ONLY)
SHOWN HEREON OR MIN 4" x 8" x 26 GA. GALV , 0.032 ALUM, OR INDUSTRY
STANDARD OEM FLASHINGS OVER ATTACHMENTS LAGGED INTO ROOF
FRAMING, E.G. SOLAR MOUNT, IRONRIDGE FLASHFOOT1or2, OTHER
ACCEPTABLE TO AHJ.
10. SF -SO ROOF ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO
SHEETING ALONE, HAVE BEEN SO TESTED AND ARE RATED AT 900-POUNDS
ALLOWABLE PER ROOF ATTACHMENT.
11. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA
PRODUCT CONTROL APPROVED (PCA) POLYURETHANE ROOF SEALANT.
12. LONG L-FEET &/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF
CLEARANCE.
13. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION:
allen@gezelmanpe.Com
ENGINEERING NOTES.
OS ALE NTS
I
IRONRIDGE RAIL.
APPEARANCE
MAY VARY
1
J
JI3/8 - 16 x 3/4
IRONRIDGEHEXHEADBOLTI
3/8-16 1 STANDARD
FLANGE BOLT OR FOR 7-IN
J/ 4 L-FOOT.
FOR1-
GALVANIZED MIN. 4 #14 X 2"
PLATE I SMS _SS
I PER ATTACHMENT
r 4
EPDM
GASKETIZL g ---3/8" SS BOLT
1l
O2 SHEETING- ONLY, SELF -FLASHING ROOF ATTACHMENTULE. NTS
9 1 8 1 7
GROUNDING PV MODULE GROUNDING
MID -CLAMP MID -CLAMP
PV RAIL
PV RAIL 3/8 - 16 x 3/4
HEX HEAD BOLT
3/8 - 16 FLANGE NUT
L-FOOT ROOF
SS METAL PLATE,
TILE
SQUARE OR ROUND /
ROOF
SHEATHING
EXISTING ASPHALT FOAEXISTING
SHINGLE
ROOF \- FLORIDA PRODUCT FRAMING 4-
MINIMUM APPROVED SEALANT ADHESIVEM
12
X 2-INCH, EXISTING FOUR # 14 CPS SCREWS SS,
SMS UNDERLAYMENT 1" BEYOND BOTTOM OF DECK
SHINGLE,
TILE, SINGLE PLY FLAT TILE ROOF ATTACHMENT O3
sUU:Nt5 0 4SCALE. NTS PV
MODULE PV RAIL EXISTING
ASPHALT IRONRIDGE \\
SHINGLE ROOF FLASHFOOT
SEE.
FIGURE 100 ROOF
SHEATHING
EXISTING
5/
16" CRS. LAG W/ 3" THREAD EMBEDMENT FRAMING IN
BLOCKING, JOIST, OR TRUSS 05
14-SHFOOT2 SHINGLE ROOF ATTACHMENT sure.
NTs PV
RAIL MID -
CLAMP EXIST -
3/8 - 16 x 3/4 HEX HEAL BOLT PV RAIL ROOF
TILE 3/8 - 16 FLANGE NUT - PV
MODULE EXIST. METAL DECKING
SERRATED
L — ON ROOF ROOF
MOUNT SHEATHING ROOF
SHEATHING -' OPTIONAL
FILL CAVITY WITH WATER TILE
ROOF DOW FOAM PROOFING STANDOFF
WATER PROOFING OR
LONG WITH SONOLASTIC EXISTING FRAMING L-
FOOT MIN. 4 #14 X 2" SMS -SS NE OR EQUAL 5/16" CRS. LAG W/ 3" THREAD EMBEDMENT 1"
BEYOND BOTTOM OF DECK POLYURETHANE CAULK IN BLOCKING, JOIST, OR TRUSS FRAMING -
METAL ROOF ATTACHMENT', BARREL
TILE ROOF ATTACHMENT ROOF COVERING COULD BE SMINGLE.TIIE, OR SINGLE -PLY. 06
SULE. Nit I D7 SCALE. NTS E
Flat
Roof Hip Roof (7° < B <_ 27°) PZ2:
ROOF PERIMETER(MIN.
3' 8 LEAST OF 40% EAVE HEIGHT
OR 10% BUILDING LJW. PZ3:
OUTSIDE CORNERS L&
W= PZ2 a =
PZ2 WIDTH., h = EAVE HEIGHT. Gable
Roof (B S Roof7Gable 7 ) GaIJIB Roof (7° < A 545°) I
tBLOr 2v9GIl !at_ D2U11 e' Z0r18E 08
ASCE 1-10 COMPONENT & CLADDING LAND PRESSURE ZONES. SCALL: NTS. I
5 Proper
Flashing Placement I1' — ®
TYPICAL SHEETING-ONLY.SELF-FLASHING. J _
SOLAR ROOF ATTACHMENT WITH OPTIONAL, UUU®
REDUNDANT WATERPROOFlNGAPPEARANCE MAY
VARY-DVNSOR RND/ETC. I
9
COMPLETED ATTACHMENT WREDUNDANT
REWNDANT WP TARGET SELFFLASHING ATTACHMENT
PHOTOS SCALE. IT'
12 I
m
d
2
3/
16 S5 PROTEA BRACKET 1 5/
8 1 1111E - 3 511E
1 <,.L 5/
16'
MINIMUM ACE CLAMP 3-INCH
THREADEMBEDMENT ,U
10
IRONRIDGE
FLASHFCi 11 APPROVED METAL ROOF CLAMPS & BRACKET SOLE_ NTSS—E- NTS IRONRIDGE Roof
Mount System XR10 Rail
XR100 Rail SIR11X10 W11 Bonded Splices r All
A low -
profile mounting rall The ultimate residential A heavyweight mounting All ralis use Internal splices for regions
with light snow solar mounting rail. roll for commercial pro]&=. for seamless connections. 8'seenrling
capability 8'spanning capability 12'spanning capability Self-dnlling screws Moderate load
capability Heavy load capability Extreme loac capability Varying versions for rails Clear and
black finish Clear and black finish Char anod¢ed finish Forme secure bonding UFOs stopper
aiaevee Grounding Lugo Mlorolnvertar lilts FisehFoot2 Slotted
L-Feet sending Hardware Fluah Standoffs a t
t 1 t FLORIDA ROOF
ATTACHMENT SPACING (FEET): ROOF HEIGHT < 30-FT & ROOF SLOPE < 30° WIND (MPH)
PZ7 P72 PZ3 IRONRIDGE RAIL 110 8
6 4 XR-10 120 8
6 2 XR-10 130 6
4 2 XR-100 140 6
4 2 XR-100 150 6
4 2 XR-100 160 6
4 1 2 XR-1000 170 1
4 4 XR-1000 180 4
2 XR-1000 12 IRONRIDGE
ROOFMOUNT SYSTEM COMPONENTS CNE'. W! 4 1
3 1 2 1 1 —144
ENGINEER
ALLEN
GEZELMAN
16502 HANNA
RD. LUTZ. FLORIDA
33549 PH.813
909 1956 A AI
len
@Gezelman PE. corn www.GezelmanPE.
com PE 59180
JUN 08
2018 EICELI Y
zz_
O
LU
Q
W J LU
0
00
2=
z
a
p
CONTRACTOR: APPROPRIATE
LICENSE
OR
OWNER/BUILDER
ID ILI
AI-
IR-
6 15.APR.
18 F 1
PHOTOVOLTAIC 3YSTEU APPROVAL CERTIFICATE
ASYARDEDTO: CERTWICATIONB: BT 17.023U
Me Sky Solar Energy OESSGHATION: SEWWH r tn SW295
IISSW Co10tMDr 9783113 SYSTEM SUE: 6,490WdC
ti1tZW Gataen. FL 34779 DATE: 2017-M14
ht4 JAMWb0u'SIty50i<3 er9y.00GV EXPIRATION: 2D22-mu
etcrxal oe•att rale bno+ina lseitaa aaaetrsKx+a atEareva ee hrntito axrrpuaerss ara aaac tcoatea eleck+cac xta malac)
aatm,bpe=4Wczmnatancwxkx2 sanViePV'Wturn:.
a Ccr4A raccwaM AroMm basis, ar4Cmntbwboats;
aamt. antat vv. nozwrawsmW4tca -daG awtpaxra* pr 0-1-V
a Raarkj and $wxbcn daO dzcorwvcb; .
oPo" CCconntown toaye Lw,,.
a PY m Aft sand cgtt ffvt omumumOnswr onoLmv wxftX two. '
a PY OC OVA and system O*W)Mq oxtoov ovwx" ek Mv* ccroWmt UZC1;
a 01%9 d fWA oftcWn b UOYLV Otf (GFDQ c'.*V andVaCb a
aBattyatrttV andcaDksages QI30P7cXkX
i
knptc=rHam litntto W.Ptcwt8O%v—l: onyx
RMOtFlH1i0t1 Calta iYrtfAasbOQ
CCc
A4dmta: Pbom towrber:.
FW133 C.rrb'J=f LteMe fArratf:
Fkr43 C,Ora'xtart am= Type:
000W a O culc3l a om f. ateac'.e =tcrr.
1tc'ebywVyVWV tPV tyzWnhmbeen tot4ed11at9acaaroance %M tat Haftmv E.3tctxgCow. r.
I
a Daft
00" Suppryslog cc
I.
faAHerd
Sao a„«s .'
150A Panelboard
with 150A main
breaker tirinimu!
Q150A-2
O Mµ,
10
30A;1
1
existing
grourrding
electrode
6600 Watt DC Photovoltaic System Electrical Diagram
Solaredge SE 5000H-U5 Inverter with
Two Strings of So(arworid SW295 Modules and Solaredge P300 Optimizers
295 SW-
295
4) irto Awr. PV wua 2-8, 2-11
1) cc B" copper
Sw-
295
1 2 (4) #10 AWG THHNMMN-2
1) 98 AWG THHN/THY H-2
Nema 311 2-B.24;L 1-G
Junction 31C EMT, FMC('inside structur
LFNC. PVC (outside structure)
Box 690.31 E
Solaredge SE5000H 44
st. Transforrnedess inverter w
integrated DC disconnect
AC
1-P- i-W
8 AWG THHNITHWH-2
LFNC, or
441- 1-W
8 AWG THHNITI WH-2
V Ifrequired by Utility 3: 30A 240V AC Disconnect with label'
On-siteUtilityGeneration DC Disconnect L Disconnect
Switch Requirements Vmpp
330 vdc PV
AC Disconnect Label Requirements Vmax 500 vdc Operating
Current: 21A impp '15.5 A Operating
vatage: 24ov Imax 30 A Bran
w A&3tftWW co C*W *dsgene*
Maximum
1 T modules per string
and minimum 8 ma 14
per string as per Solaredg Fact
CO." Solarworld
sw295 Mon cations
atarctnpltpowar.
30o wpm: 295Wp sttax.
input t>CVottage:4a YOG Vol 39,7V Max
InputcurrenMPPT Max
output Voltage: t
12.SA Vnrpp; 32.4V Range: WG Ise: 9.61 A Y8CItnpp: 9.10A Atacoutputar€rerrf; i5A 8
Notes:
All work to meet or exceed NEC 2011 t
Junction box to be located within the array boundary. Junction box must be minimum Nema 3R UL listed enclosure.
Free air conductors must be installed in raceway if readily accessible as per 690.31(A). 2
he minimum volume of the Nema 3R enclosure for the transition of PV wire to THWN-2 wire shall be 42
cubic inches. Heyco 5 wire Masthead gland seals or similar connector are required as strain relief for
PV wire into Nema 311 junction box at array, Interconnection
with 30 Amp 2 pole OCPD via 2011 NEC 705,12(D)(2)Load Side Connection. The 30 A backfed
breaker must be located at the opposite end of the bus from the 150 A main supply breaker t
The required PV Backfed breaker plus the main breaker rating must be less than or equalto 120%of the
Main service bus rating. 10512(D)(2) 5
Optional Supply Side connection via 705.12A using parallel lime taps in a NEMA 3R box (as required) using
NSi IPCSd002, Ilsco IPC-KUP-L orNSI Tork IPLD 31t1.33 Multi -Tap Connecto€'orequivaient PV
service disconnecting means for "optional" supply side connection must have neutralf' EGC bond within
and rturst be listed as -suitable for use as service equipment" 230.66 7
The fuses in the disconnectfor the`suppty side option must be rated to handle the maximum short- circuit
current available at the supply terminals. 110.5.110.10 Oyer -current protection for the supply side connected
conductors shall be located within 10 feet of the connection to the service:. 705.31 tS
Grounded conductor shall be routed with ungrounded conductors, to PV Service disconnecting means as per
250.24(C) if -Supply Side" option is used, 9
For "Supply Side option" Continuous or irreversibly spliced Grounding Electrode conductor installed per
25024(D): Grounding Electrode Conductor shall be specifiedas per 250.64 and sized per 250.66 DO
The following label is required on meter can and main panelboard "Services fed from dual power sources Utility
and Photovoltaic system" a"PV input Do not relocate this OCPD- labelrequired adjacent to backfed breaker. 705,12(cro 12 ding
of module to rang and module to module accomplished through WEEB washers or self grounding mid -clamps.
130 3 "Warning: DC conductors of this system are ungrounded and maybe energized" required on the 0 DCDisconnect690.35E 14- "warning:
Photovoltaic Power Source" label required on conduit per 690 31(E)(3)(4) IS- Total
voltage drop % for all circuits based on listed conductors is 1.65%based on: A 100
foot round trip PV wide open air rum to Nema 311 junction box 8.150
round trip source circuits (THWN-2) to termination in DC disconnect C.30
feet round trip Inverter Output circuit to point of interconnection, D. Conductors
should be sized for max 2%voltage drop to decrease possible inverter shutdown
and production losses due to AC voltage rise at the inverter.
Sunmodule;/" Plu's H u' to
SWA 290 300 MONO
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC)'
SWA 290 SWA 295 SWA 300
Maximum power Pm„ 290 Wp 295Wp 300 Wp
Open circuit voltage V., 39.6 V 39.8 V 40.0 V
Maximum powerpointvoltage VmPP 31.9 V 32.3 V 32.6 V
Short circuit current 1„ 9.75 A 9.78 A 9.83 A
Maximum power point current ImPP 9.20 A 9.25 A 9.31 A '
Module efficiency qm 17.3 % 17.59 % 17.89 %
Measuring tolerance (P,,,,„) traceable toTUV Rheinland: +/- 2% STC:1000W/m, 25'C, AM 1.5
PERFORMANCE AT 800 W/M2, NOCT, AM 1.5
SWA 290 SWA 295 SWA 300
Maximum power Pm„ 219.6 Wp 223.6 Wp 226.7 Wp
Open circuit voltage V° 36.7 V 36.9 V 37.0 V
Maximum power point voltage Vmpp 29.5 V 29.9 V 30.2 V
Short circuit current I„ 7.99 A 8.01 A 8.06 A
Maximumpower point current ImPP 7.43 A 7.47 A 7.52 A
Minor reduction in efficiency under partial load conditions at 25 °C: at 200 W/m2, 97% (+/-3%) of the STC efficiency (1000 W/m') is achieved.
PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION
Powersorting -0 Wp /+5 Wp pvE \ E 171 00%rill
1000VMaximumsystemvoltageSCll/NEC N9" :".noa° o
Maximum reverse current 25 A 37.8 (961)
Number of bypass diodes 3
Operating temperature -40 to +85 "C
4.20 } 00106,65)1 4x =
Maximum design loads (Two rail system)" 113 psf downward, 64 psf upward 7.12 00.26(6.6)
Maximum design loads (Three rail system)' 178 psf downward, 64 psf upward 180.85)
Please refer totheSunmodule installation instructions for the details associated withthese load cases. ii' 0.35(9)
COMPONENT MATERIALS 0
Cells permodule 60 m
Cell type MonocrystallinePERC g ^
Cell dimensions 6 in x 6 in (156 mm x 156 mm) O
Front Tempered safety glass with ARC (EN 12150) O
Back Multi -layer polymer backsheet, white a
Frame Black anodized aluminum
J-Box IP65
Connector PV wire (UL4703) with Amphenol UTX connectors
Module fire performance (UL 1703) Type 1 00.35(9)
DIMENSIONS / WEIGHT THERMAL CHARACTERISTICS 11.32
287.50)
Length 65.95 in (1675 mm) NOCT 46 `C
Width 39.40 in (1001 mm) TC I„ 0.07 %/C II1.-- 39.4 (1001)
Height 1.30 in (33 mm) TC -0.29 %/C II 1.30 (33)
Weight 39.7lb (18.0 kg) TC P-PP -0.39 %/C All units provided are imperial. SI units provided in parentheses.
ORDERING INFORMATION CERTIFICATES AND WARRANTIES
Ordernumber Description IEC61730 IEC61215 UL1703
Certificates
82000482 Sunmodule Plus SWA 290 mono (black frame) IEC 62716 IEC 60068-2-68 IEC 61701 o
82000430 Sunmodule Plus SWA 295 mono (black frame) Product Warranty 20years o
82000432 Sunmodule Plus SWA 300 mono (black frame)
Warranties"
Linear Performance Guarantee 25years
Supplemental warranty coverage available through SolorWorld Assurance'
Warranty Protection Program - www.solorworld-uso.com/assurance r
0
SolarWorld Americas Inc. reserves the right to make specification changes without notice. This data sheet complies with the requirements of EN S0380.
t
for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US /
SE7600H-US
USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL-TURKEY-SOUTH AFRICA-BULGARIA www.solaredge.us
solar— 1 Single Phase Inverters for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ SE760OH-US
SE3000H US''I" ,''SE3800H US,,,i f`SE5000H US, SE6000H US r tSE7,606H;;U5 ,
Y lYav;r
Rated AC Power Output 3000 3800 5000 6000 7600 VA
Max. AC Power Output 3000 3800 5000 6000 7600 VA
AC Output Voltage Min.-NomMax. (183 - 208 - 229) Vac AC
Output Voltage Min: Nom.-Max. (211 - 240 - 264) I ...... ........
I ..... I. Vac
AC
Frequency (Nominal) 59'.3 - 60 - 60.51'I Hz Maximum
Continuous Output Current 208V 24 ................. A Maximum
Continuous Output Current 240V . 12.5 16 21 25 32 I A GFDI
Threshold 1 A Utility
Monitoring, Islanding Protection, Country
Configurable Thresholds Yes
tlNPUT,
a „, t ,a Maximum
DG Power 4650 5900 7750 9300 11800 W Transformer -
less, Ungrounded ........................................ Yes Maximum...
Input,.. Vo.ltage480 Vdc Nominal
DC Input Voltage No380 400 Vdc Input
Current 208V 13.5 ...... Adc ximum
Input Current 240V til...................... Maximum8.5..... 10.5 13.5 16.5 20 I........ .................... .................... Adc Max.
Input Short Circuit Current 45 Adc .... I....
Reverse -
Polarity Protection ................................. Yes I ......
Ground -
Fault Isolation Detection 600kn Sensitivity Maximum
Inverter Efficiency ....................... 99. ( 99.2 CEC
Weighted Efficiency 99 Nighttime
Power Consumption 2.5 W FADDITIONALFEAT,
ES Supported
Communication Interfaces pp ....rage ......
ANSI ...... ..... .. .. ... .. ....... .. F.. g
Cellular (optional) RS485, Ethernet, Zi Bee(optional), 131..............................................
nRevenueGradeData, ANSI C12.20 Optional Rapid
Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STSfVDA'
RD,COMPLIANCE,=,'q ( izl ,a 4.,1 rt lian Safety ................................................................................................................................
UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T I_L: Connection
Standards IEEE1547, Rule 21, Rule 14 ( HI) Grdi............................................................................................................................................................................. Emissions
FCC Part 15 Class B tINST?
LLATIONSPECIFICAT;IO,NS.-`_`it AC
Output Conduit Size / AWG Range 0.75-1" Conduit / 14 6 AWG DC
Input Conduit Size / # of Strings / AWG Range 0.75-1' Conduit /1-2 strings / 14-6 AWG Dimensions
with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 ................................. in / mm Weight
with Safety Switch22 / 10 25 1 / 4 26.2 / 11.9 I................
lb / kg Noise
25 ....... _................ .............. ........ <50 dBA Natural
convection
and Cooling
Natural Convection internalfan user
replaceable)...
Operating
Temperature Range 13 to +140 / -25 to +60 °' (-40'F / -40°C option)i51 F /'C Protection
Rating NEMA 3R (Inverter with Safety Switch) hI
For other regional settings please contact SolarEdge support l
l A higher curree may be used; the inverter will limit its input current to the values stated 631
Revenue grade nt
invsourcerter
P/N: SExxxxH-USOOONNC2 Icl
Power de -rating from 50'C Isl-
40 version P/N: SDM-USOOONNU4
solar
SolarEdge Power Optimizer
Module Add -On For North America
P300 / P320 / P400 / P405
n
ME
USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA -AUSTRALIA -THE NETHERLANDS-UK-ISRAEL WWW.SOIBYedge.US
solar=@ S®IarEdge P®wer Optimizer
Module Add -On for North America
P300 / P320 / P400 / P405
P320'AaP400 P405P300 'f high power for 72 & 96=cell for thm film
yb_,u,o
for 60 cell modules)
n ,. 60-cell-rnodules;,` modules), modules) ,_
1}, q i'<r P',# aINPUT, . rtx4+. r a ,. t i
Rated Input DC Powerltl 300 320 400 405 W
Absolute Maximum Input Voltage 48 80 125 Vdc
Voc at lowest temperature
MPPT Operating Range ............................................. 48...................................... 80...................12:5 . 105............ Vdc.....
Maximum Short Circuit Current (Isc) 10 I 11 10.1 Adc
Maximum DC Input Current.......................12:5...................... 13.75....................................12:63............................. Ad .....
Maximum Efficiency, ............ ....... 99.5
WeightedEfficiency..................... 98:8 ............................................................
Overvoltage Category II
OUTPUT DURING OPERATION (POWER,OP7IMIZER CONNECTED4T0OPERAT.ING SOLAREDGE"IN1/ERTER)nx,
Maximum Output Current 15.. Adc
Maximum Output Voltage 60 85 Vdc
OUTPU,T DURING,STAND'BY (POWER OPTI_'MIZER`EDiSCQNN,ECTED.FROM,SOLAREDGEsINU,ERTER OR SOLARED;GE,I,NVERTER-OF,F.)
Safety Output Voltage per Power 1 VdcOptimizer
STANDARD`COINIPLIAIVC.E tJ. ,=q Nf
EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
SafetY............................... IEC62109:1 (class II safety), UL1741
RoHS Yes
INSTALLATIOIV.SPECIFICATIONSft
Maximum Allowed System Voltage 1000 Vdc
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
128x152x27.5/ 128x152x35/ 128x152x50/
Dimensions(WxLxH) mm/in
5x5.97x1.08 5x5.97x1:37 5x5.97x1.96
Weight (including cables)......................................760 1.7 830 / 1.8 ............1064 / 23...........r./ Ib
Input Connector MC4 Compatible
Output Wire Type /Connector Double Insulated; MC4 Compatible
Output Wire Length 0 95 / 3 0 I 1.2 / 3 9 m / ft
Operating Temperature Range 40 +85 / -40 -+185 C /'F
Protection.Rating IP68 / NEMA6P
Relative Humidity 0 100
M Rated STC power ofthe module. Module of up to +5% power toleranceallowed.
Minimum String Length 8 10 18
Power 0 timizers
Maximum String Length 25 25 SOPowerOptimizers)
Maximum Power per String ........................... 5250............................... 6000..............................12750.................... W
Parallel Strings of Different Lengths Yes
or Orientations
ICI It is not allowed to mix P405 with P300/P400/P600/P700 in one string.
i .. aDec
FLASHED PV ROOF -MOUNT: Cf3M81NERIENCt4SURE
Basic 'Features
Starred Sea rniess, Construction
18 Gauge Galvanized Steel
Powder Coated Surfaces
Flashes into the roof deck
0 3 Roof deck knockotits ..T, .76. V
5 Cantering dimples for entry/exit
fittings or conduit
2 Poston Ground tug installed
e Mounting Hardware Included
socUr Mo" $D 0783
SolaDeck UL54 Type 3R Enclosures
Available Models
Me" SD 0783 - (Y tixea W RA
Model SO 0766- (6' sWod Din Ral)
SolaDeck UL 1741 Combiner/Enclosures
Modes $0 0783.41 and $a 070.41 bb00o *rsd ETL 14*d ULsm 1741
acmdrq to 0* lit STD 1741 for ph+oWoltaic om biser enciaaums.
Max Rated - 600VOC. 120AM PS
Model SD 0783-41 X Fixed Din Rail fastened using Nodock System
Typical System configuration
4- Din Rai Mounted Fuse Holders 600WC 30 AMP
1• Power Distribution Block'600VDC 176AMP
1. Bus Bar with Ut
Mod*) SD 0786.41 6' Slottod Din Rail fastened using stool studs
Typical System Configuration
4- Din Rai Mounted Fuss Holders 60OVDC 30AMP
4- Oin RaR Mound Terminal Blocks
Bus Bars with UL lug
Fvso tvl m aid WmkW 0*03
Owed h a* tid Host t* kX Igo ar
Moog*b4 And OX* 600 WC 30AMP
110C txkno to)4gra. MW$OAMP
9W ow ra vloknxd tMkni bloc"
ord 600 V 176AMP WC for Po w
aamen Blacks, two cW90 wra
coiar 4t6tm ato WOW
otYXkA or forgs bza is,
W& d row for ftm
MOON $0 0783.41. r IMO 1 Mood so 07664 t. WW wkh
W RBI rrbtrritod hrko trsldors an Roil mw tad Lase hddvs,
tarst>w ord pow dsrbt ot Lamina bJoft WW W$ bars.
bk>«
RSTC Enterprises, Inc 2219 Heimstead Road Eau Cliare, tM 54703
Forproductinfomation caa 1 f866j367-7782
REQUHR E D NSPEC'TION SEQUENCE
Min Max, ]Ins2eetionn. DescrIttion
Electric, Underground
Footer [Slab Steel Bond
Electric Rough
T.0 G.
Pre -Power Final
Electric Final
Minn Max I<nsecdon IlDescn°ipti®nn Plumbing
Underground _ Plumbing
Sewer Plumbing
Tub Set Plumbing
Final Min
Mam I<ns a tionn llDescri • tion Mechanical
Rough,'. Mechanical,
Final, Min
Maw' lCns eetn®n. Description Gas
Underground Gas
Rough - Gas
Final
Gulf Electrical Service. ELC.
453 N Dixie Ave, Titusville FL 32796
813-230-1287
State Licensed Electrical Contractor EC13001255
September 11,18
TO: City of Sanford
300 N. Park Ave., Sanford, FL 32771
CONTRACTOR'S PERMIT CANCELLATION LETTER
I, Daniel Yates: license holder for Gulf Electrical Services LLC, Florida License Number: EC13001255,
hereby request the cancellation of a customer cancelled project, Permit 4: 18-00002881 for the
address listed below:
Freeman, Sarah. & George
261 Venetian Bay Circle, Sanford FL 32771
407-474-3830
The customer cancelled the project after we had secured this permit, so please cancel this permit.
No work was performed or will be performed on this permit.
Contractor's Signature
Contractor's (Printed) Name: Daniel Yates
STATE OF FLORIDA
COUNTY OF HILLSBOROUGH
The foregoing instrument was acknowledged before me this 11th day of September 2018
by Daniel Yate ho is personally known to m r has produced identification
Notary Signature
Notary Printed Name: ichael Tyner Rigtess.otFlorida
rn GG 239750
2022