HomeMy WebLinkAbout114 Circle Hill Rd - BR18-004715 - PATIO DOOR12/04/2018 05:33PM 4076340400 LISACOOK DECKERDOORS PAGE 20
CITY OF SANFORD
BUILDING & FIRE PREVENTION
PERMIT APPLICATION
Application No: -
Documented Construction Value: $ 1857.69
Job Address: 114 Circle Hill Rd. Sanford, FL 32773 Historic District: Yes No
Parcel fD: 04-20-30-514-0000-0080 Residential X® Commercial
Type of Work: New Addition Alteration Repair Demo Change of Use Move
Description of Work: Replace rear patio door unit size for size
Plats Review Contact Person:
Phone: Fax: Email:
Title:
Property Owner Information
Name Jades and Melanie Held Phone: 407-280-4554
Street: 1307 Live Oak St. Resident of property? :
City, State ,Zip: New Smyrna, p1, 321 68
Name Daniel T. Decker
Street: 724 Brooks Court
City, State Zip: Winter Springs, FL 32708
Name:
Street:
City, St, Zip:
Bonding Company:
Address:
Contractor Information
Phone: 407-696-0830
Fax: 4Q7-696-7356
State License No.: CBC1250499
ArchitectfEngineer Information
Phone:
Fax:
E-mail: T
Mortgage Lender:
Address:
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAX RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON TIME JOB SITE BEFORE THE !FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OFCOMMENCEMENT.
Application is hereby made to obtain a permit to dd the work and installations as indicated. 1 certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction
in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc.
FRC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: Sei Edition (2014) Florida Building Code
Rcuised: June 30, 2015 Permit Application (
12/04/2018 05:33PM 4076340400 LISACOOK DECKERDOORS PAGE 21
In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be
found in the public records ofthis county, and there may be additional permits required from other governmental entities such as water
management districts, state agencies, or federal agencies.
Acceptance ofpermit is verification that I will notify the owner of the property of the requirements ofFlorida Lien Law, FS 713.
The City of Sanford requires payment of plan, review fee at the time of permit submittal. A copy of the executed contract is required
in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal.
The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, it)
accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value,
credit will be applied to your permit fees when the permit is issued.
QWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning.
Signature ofOwner/Agent
Print Owner/Agent's Name
Signature ofNowy-State of Florida Daze
Owner/.A.geat is Personally Known to Me or
Produced ID Type of ID
Daniel T. Decker
P i or/Agent's Name
W4,
Si ofN State of Florida Date
ELIZABETH GOOK
h1v COMMISSION # GG 189555
EXPIRES: Jamaary 10, 2021
C(N..d Thru Natary Public Underwriters
COntraCtor/.Fig IN
Produced ID Type of ID
BELOW X_ R OFFICE USE ONLY
Permits Required. Building Electrical Mechanical Plumbing Gas Roof[]
Construction Type: Occupancy Use: Flood Zone:
Total Sq Ft of Bldg: Min. Occupancy Load: # of Stories:
New Construction: Electric - # of Amps Plumbing - # of Fixtures
Fire Sprinkler Permit: Yes No [] # of Heads Fire Alarm Permit: Yes No
APPROVALS: ZONING: UTILITIES: WASTE WATER:
ENGINEERING: FIRE: BUILDING:
M&
el
COMMENTS:
Revised: June 30, 2015 Permit Application
I hereby name and appoint:
LIMITED POWER OF ATTORNEY
0
Print Name of Appointee)
Decker Doors, Inc.
Company Name ofAppointee)
to be my lawful attorney -in -fact to act for me in applying to
Government commercial / Residential Permitting for a permit enabling workYo be performed at the location
below — described and to sign my name and do all things necessary to this appointme nt:
Section
20 Township
Range
Subdivision
Block
90 Lot
Project Address)
Fill (Owner of Property)
certified contractor signature)
Certified Contractor: Daniel T. Decker
printed name)
State ofFlorida
County of Orange
Sworn toand subscribed before noethis dayof by Daniel
T. Decker _(name of person acknowledged) who is personally known to me. Notary
Public) Commission
expires: FORM
power of attorney/042501/dv 7
7 EAondedl
12/04/2018 05:33PM 4076340400 LISACOOK DECKERDOORS PAGE 22
RECEIVED 12/04/2016 11:47AM 4076340400 LISACOOC DECKERDOORS
2018-12-04 10:43 Home Depot 0264 COS 4073/331117 >> 4076340400 P 1/1
Home Improvement Agreement: Page 2
I,
Descdptiori of Work -to be Performed....
A detailed description of the work to be performed is included In the paragraph entitled Scope of Work
or Specification which is included In this Agreement,
Anticipated Delivery Date Tin>cWTiro $0tW We - _..._ .. .
Approximate Start Date: ITUD Approximate Finish Date: Tep All dates are approximate
and subject to change based on unforeseen events including inclement weather, permitting delays, anddelaysinoonfrrm! g insurance coverage of Your claim for any repair, if applicable.
Electronic' Records Ati'thorimboi n
You are entitled to a paper copy of this Agreement if you choose. If you consent to an e-mailed copy,
your consent applies to this Agreement and all subsequent documents and written communications
related to this Agreement. By contacting your Service Provider, you may update your email address,
withdraw your consent, or obtain a paper copy of the Agreement or related documents at no charge. By
providing your consent and verifying your email address above, you confirm that you have access to a
computer that can receive and open emalls and pat= documents.
I do do not Consent to receive only electronic records related to this transaction.
Contract fte and Payrrierlt Schid4he
Payment of the Contract Price is due upon signing unless a different payment schedule Is required by
low, specified below or in a payment addendum.
Contract Price: $ Includes all applicable taxes, Excludes finance charges."
Sales Tax: $ o.00 (If applicable, total amount of taxes Included in Contract Price)
Maximum deposit ONLY applicable in MD, MA, ME (33%), NJ, Wl (99%)
Deposit % Deposit Amount $ Remaining Balance $
IFinanceRharges _.....----- ..,......._...__.._. .._...... ............ ........ ...
Aity'interest payment% or other finance charges will be' datermined by Customers separate cardholder
or loan agreement, to which Home Depot is NOT a party, and will be In addition to Customer's payment
under this Agreement. Customer is subject to the terms and conditions of the cardholder or loan
iagreament, as applicable. No funds should be made payable to Service Provider, however, Service
Provider may collect Customer's payments made payable to Home Depot.
Insurance proceeds will will not be used to pay some or all of the total amount of sale.
A60*e'ptamce iw Authorization' ............__. _......._...
By signing below, you authorize Home Depot to: (a) arrange for Service Provider to perform any
Services or (b) order and arrange for the delivery of special order merchandise, Including special
order merchandise that may be custom made, as specified In this Agreement. Do not sign if blank or
Incomplete. (Service Provider's or permitting information may need to be provided to You later.) By
signing, you acknowledge that: (1) You have read, understand, and accept this Agreement in its entirety,
including the General Conditions and State Supplement, if any: (ii) You are receiving a complete copyofthisAgreement; (iii) all rights and interests under this Agreement are solely vested in the personlistedas "Customer" above; and (iv) Electronic signatures will be deemed originals for all purposes.
X t2ro trzv a
Customer's Signature Date
X The Fttxns Depot Digital $ignattre t210112016
The Home Depot Digital Signature Date
Call The Home Depot at 1.800-466.3337 for help
12/04/2018 05:33PM 4076340400 LISACOOK DECKERDOORS PAGE 23
RAA -$T67fPropertyRecordCardt -7
Parcel: 04-20-30-514-0000-0080
Property Address! 114 CIRCLE HILI, RD SANFORD, FL32773
Pamal Information
Parcel 04-20-30-514,0000-0080
Owneqs) HELD, MELANIE J
HELD, JAMES D
Property Address 114 CIRCLE HILL RD SANFORD, FL 32773
Mailing 1307 LIVE OAK ST NEW SMYRNA, FL 32168.7738
Subdivision Name MAYFAIR CLUB PH 2
Tax District 11-SANFORD
DOR Use Code 01-SINGLE FAMILY
Exemptions
50 99.54
00
CID
it
50 50.11
Legal Description
LOT 8
MAYFAIR CLUB PH 2
PB 54 PGS 84 & 85
Taxes
Value Summary
2019 Working 2018 Certified
Values Values
Valuation Method Cost/Market Cost(Market
Number at Buildings
Depreciated Bldg value 163,560 ri155.461
Depreciated EXFT Value
Land Value (Market) 35,000
Land Value Ag
just/Market Vali,io 198,560 190.467
Portability Adj
Save Our Homaa AdJ
Amendment
0 0
1 Adj so 0
P&G Adj
Assessed Value
Tax Amount without SOH: $3,574.94
2018 Tax Bill Amoi,i[a $3,574.94
Tax Estimator
Save Our Homes Savings: $0.00
Does NOT INCLUDE Non Ad Valorem Assessments
Taxing Authority Assessment value Exempt Values Taxable Value
County General Fund 198,560 0
4
8, $195 60 ;
Schools 0 198,560
198,560CitySanford 0
1... , I
SJWM(Saint Johns Water Management). 198,560 0
County Bonds 198 0
sales
Description
WARRANTY DEED
SPECIAL WARRANTY DEED
Find Cemi tgabk Bolas
Land
Method Frontage
LOT T
Qualified VaulmpDatePageAmount
1211t2002 DAM 1196 $160.000 Yes improved
M IZQ $109,300 Yes Improved
Depth Units Units Price Land Value
35,000,00 135.000
Building Information .......
jcorrect? Cli H
Year Built07;ZrIption Fixtures Bed Bath NaSo Area I Total SF Living SF Ext Wall Adj Value Repl Value AppendagesActual/Elfective
I SINGLE 1999 7 1,87411 2,290 1,874 i CB/STUCCO) $163,560 175.871
PERMIT# Z
a
cx-
G
OFFICE
FL # FL22363-R2
Application Type Revision
Code Version 2017
Application Status Approved
Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Masonite International
Address/Phone/Email 1955 Powis Road
West Chicago, IL 60185
800)663-3667
sschreiber@masonite.com
Authorized Signature Steve Schreiber
sschreiber@masonite.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
Referenced Standard and Year (of Standard) Standard Year
ASTM E1886 2005
ASTM E1996 2009
ASTM E330 2002
TAS 202 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 12/01/2017
Date Validated 12/04/2017
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRg6J4gMSl%2b6PsUbsDh5sB24Q%3d%3d 1/5
1/14/2018 Florida Building Code Online
Date Pending FBC Approval
Date Approved 12/06/2017
Summary of Pro ucts
FL # Model, Number or Name ; Description
22363.1 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant. Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, in luding the High Velocity Hurricane Zone, and
where pressure r quirements do exceed the design pressures
listed. 3'-0" x 6' " max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG MA-WL0187 for details.
6'-8" Opaque I/S Single Door
Certification Agency Certificate
FL22363 R2 CAC N10137i7 17-R1 Odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FLO187.Qdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514010A.Ddf
F 2L2363R2AE14014A.Ddf
Created by Independent Third Party: Yes
22363.2 Fiberglass Side -Hinged Door Unit j 6-8" Opaque O/S Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resists t: Yes
Design Pressuro: +60/-60
Other: Evaluate for use in locations adhering to the Florida
Building Code, in uding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 6'4' max nominal size. Hurricane protective
system required im HVHZ, but not in the Wind Borne Debris
Region. See DWGt'MA-WL0187 for details.
22363.3 ; Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for u e in HVHZ: Yes
Approved for u e outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0187 for details.
22363.4 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0189 for details.
Certification Agency Certificate
FL22363 R2 C CAC N101371717-R1 pdf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FL0187 Ddf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL223 3 R2 AE 514010A Ddf
FL22363 R2 AE 514014A.Ddf
Created by Independent Third Party: Yes
6-8" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
1`1_223 3 R2 C CAC NI013717 17-R1 Ddf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL223632II F1_0I87 Rdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514008A.pdf
FL22363 R2 AE 514012A.Ddf
Created by Independent Third Party: Yes
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FLZZZ 6 R2 C CAC NIQ 31717OIR1odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FLQ189.gdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FLZ2363 R2 AE 514QQQA,,p
FL22 R2 AE 401A pdf
Created by Independent Third Party: Yes
22363.5 Fiberglass Side -Hinged Door Unit 6'-8" 3/4-Lite Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6'-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0193 for details.
Certification Agency Certificate
FL22363 R2 C CAC NI013717Q4-R .W Quality
Assurance Contract Expiration Date 05/
31/2021 Installation
Instructions FL22363
R2 II FLQ193.12df Verified
By: National Accreditation & Management Institute Created
by Independent Third Party: Evaluation
Reports FL22363
R2 A 4_ 00A Ddf https://
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRg6J4gMSl%2b6PsUbsDh5sB24Q%3d%3d 2/5
1/14/2018 Florida Building Code Online
FL22363 R2 Ar 5jA 2A pdji
Created by Independent Third Party: Yes
22363.6 j Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed, 12'-0" x 6'-8" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0195 for details.
6'-8" Impact Glazed I/S or O/S Single or Double Door w/ or
w/o Sidelites
Certification Agency Certificate
FL22363 R2 C CAC N 13717 05-RI todf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FL0195 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party: Yes
22363.7 Fiberglass Side -Hinged Door Unit 8'-0" Opaque I/5 Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-65
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
Certification Agency Certificate
FL22363 R2 C CAC N1013717 18-R1 pdf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II l L4ll t df
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514009A odf
FL2-2363 R2 AE 514013A.odf
Created by Independent Third Party: Yes
22363.8 Fiberglass Side -Hinged Door Unit j 8'-0" Opaque O/S Single Door
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 3'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
22363.9 j Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ, but not in the Wind Borne Debris
Region. See DWG-MA-WL0188 for details.
22363.10 i Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +40/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
See DWG-MA-WL0190 for details.
Certification Agency Certificate
FL2236a R2 C CAC N1013717 18-Rl,gdf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 I _ELQjB3adf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514009A.odf
Created by Independent Third Party: Yes
8'-0" Opaque I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FLZ23363 R2 C CAC NI0I3717 18-R1 odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL ?7 263 R2 II FL0188 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514007A.i coif
FU2363 R2 AE 514011A.Ddf
Created by Independent Third Party: Yes
8'-0" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22363 R2 C CAC N1013717 08-R1 pdf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
F R2 lI FL0190 odf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514007A.Ddf
FL22363 R2 AE 514011A.odf
Created by Independent Third Party: Yes
22363.11 Fiberglass Side -Hinged Door Unit 8'-0" Impact Glazed I/S Single or Double Door w/ or w/o
Sidelites
https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRg6J4gMSl%2b6PsUbsDh5sB24Q%3d%3d 3/5
1/14/2018 Florida Building Code Online
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +40/-45
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0196 for details.
22363.12 Fiberglass Side -Hinged Door Unit
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +45/-40
Other: Evaluated for use in locations adhering to the Florida
Building Code, excluding the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system not required in the Wind Borne Debris Region. See
DWG-MA-WL0196 for details.
22363.13 HPC Fiberglass Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +47/-47
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 8'-0" max nominal size. Hurricane protective
system required in HVHZ and in the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG-MA-WL0192 for
details.
22363.14 HPC Fiberglass Side -Hinged Door
Unit
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: Evaluated for use in locations adhering to the Florida
Building Code, including the High Velocity Hurricane Zone, and
where pressure requirements do exceed the design pressures
listed. 12'-0" x 6-8" max nominal size. Hurricane protective
system required in HVHZ and the Wind Borne Debris Region.
Door top rails stamped "HPC". See DWG-MA-WL0191 for
details.
Certification Agency Certificate
22363 }Z C CAC NI01 i717.09 Rl.odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FL0196.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R AE 514007A.rdf
FL22363 R2 AE 514011A.gdf
Created by Independent Third Party: Yes
8'-0" Impact Glazed O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22563 R2 C CAC NI013717.09-Rl.odf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 B2 II FL0196,12Qf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514007A.pdf
FL22363 R2 AE 514011A.Ddf
Created by Independent Third Party: Yes
8'-0" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
FL22¢ R CAC NI013717,07-R1,p f
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 II FL0192.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
FL22363 R2 AE 514007A.Ddf
2363 R AE 514011A.Ddf
Created by Independent Third Party: Yes
6'-8" Glazed I/S or O/S Single or Double Door w/ or w/o
Sidelites
Certification Agency Certificate
F AC NI013717.Q2-Rj.pdf
Quality Assurance Contract Expiration Date
05/31/2021
Installation Instructions
FL22363 R2 11 FL0191.pdf
Verified By: National Accreditation & Management Institute
Created by Independent Third Party:
Evaluation Reports
j RZ 8E 514008A.i?df
FL2 363 $Z 8L 51401 A.D0f
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee Ft 32 9999 Phone: 850.487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 state of Florida.:: Privacy Statement :: Acc s i ili Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, If you have any questions, please contact 850.487,1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Acce'Atplts: MM
t'l llt"11.„Si 21tit.1
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPOv7Ro8yOHRg6J4gMSl%2b6PsUbsDh5sB24Q%3d%3d 4/5
NOTICE OF PRODUCT CERTIFICATION
l Company: Masonite International Corporation Certification No.: N1013717.04-R1
1955 Powis Road Certification Date: 05/12/2017
West Chicago, IL 60185 Expiration Date: 05/31/2021
Revision Date: 11/20/2017
Product: Fiberglass Glazed Inswing or Outswing Door w/ and w/o Non -Impact Rated Sidelites
3/4 Lite of Less Doors w/ and w/o Full-Lite or Less Sidelites (w/Wood Frame or Worldwide
Composite Frame' unless noted)
Specification: TAS 202-94/ASTM E330-02 Glazing: Insulating Glass (Tempered)
The "Notice of Product Certification" is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents
product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within N.AMI's Certified Product Listingatwww.Namicertification.com. NAMI's Certification Program is accredited by The American National fitandardc lnctifido tpNcn
Inswing Glazed
Configuration or or
Outswing Opaque
X
Maximum
Size
Structural
Resign
Pressure
Water
Test
Pressure
Missile
Impact
Rated
I Test Report Number
Drawing Number &
Comments
US Glazed 3'0., x 6'8" 50/-50 0.0psi No iATi \'C' 1012.01-1GR Single
3.4-1_ite Max Maximum Panel Size 3'0" x 6'8" Anchor
Details DWG-M 1-F'i.019>-17 X
OIS Glazed 3 0" x 6'8" 501-50 3.75 psi' No ATLNC 1012.07 16R/w 1813iW-1843 Single
3s4-Lite Max 6,0 psf i Maxinniin Panel Size. 3'0' x 6's" 8,
25 psi" i .Anchor Detail--DW6-MA-F1-0393-17 j Glazed
Double
3,4-Lite Max 6'
0" x 6'8" 50/-50 0 psf No i ATi ,,xc 1012.01 i6t Maximum
Panel Size 3 0" x 6 8'" Anchor
Details -DWG, ,MA-FL0193-l? XX
O/S I— Glazed 6'0" x 6'8" r50.%%-50— 3.75 psf' No ATLNC 1012.01-16R; 1813tW-lW, Double
I 3;4-Lite Max 6.0 psf ` Maximum Panel Size 30" x 6'8" 8,25
psf' Anchor Dclails-DW'G-MA-1-1.0193-17 kOiOX F'
S Glazed Single W.
Sidelite 3/4-Lice Max 6 0"
x 6'8" i 501-5U 0 psi' Door -No Sidelite-No
ATLNC 10I2.
01 16K Maximum Panel
Size: 3'0" x 6'8'- Full-Irte
Max S%1, O/S
Anchor Detail;-
DWG-MA-FL0193-17 XO/OX
Glazed 6'0" x 6'8" 50/-50 3.75 psi' Door -No ATLNC 101101-16RJW-Ix13: W-1843 Single w,/
Sidelite 3r4-Lite Max fi.0 psf" Sidelite-No Maximum Panel Siz: 3'0"' x 6'8" Full-Lite
Max S/L 8.25 psf' Anchor Detail -DWG-M A-FLU193-17 US Glazed
90" x 6 0 ATi vC 1012.01 I6R0XO - -- — Sinole W/
Sidelite. I 3=4-Lite Max Sidelites-No Maximum Pane? Size. 3*0".x t+'8" I—__ l
all-Lite Max S/l: Oxo OIS
Glazed 9'0," x OX, 50/-50 3,75 psP Door -No Anchor Detail-
Dt'G-MA 1`1,0193-1 ;' ATLNC 1012
03 I6R w 1113Wi843 Single w/Sidchlea
3 4-Lite Max 0.0 psf Sidelites-No Maximum Panel Size O x 6'8" Full -Lice Max
SiL 8.25 psi ` 9,0 psi
Anchor Details-DWG-
MA-bL0793-17 OXXO liS Glazed
1 2'4" x 6'8" j 501-30 0 psi' i)oor-No A`l LINC 1012 of 16R Double w/Sidelites
j '4-Lite Max if Sidelites-No Maximum Pan Sizc 0" x 6'8' 1 full-Lite
Max &I OXXO oIS Glazed
Glazed l'4"x 6.8.. 50/_50 3 ypsi' Door -No Anchor Deiail DWG-
MA-hl 0193-1 7 ATLNC llli 21
1fiiU1 1873;W'-lsa3 Double w/Sidelites
3 4-Lire Max 6.0 psf Sidelitse-No Maximum Panel Siz: ; 0°' x 6 R„ Full-Lite Max
S/L 8.25 psi Anchoi Dctasls DWG-A4A-FL0i93-1? 8.25psf' 1 -
Denotes Bumper
Outswing I hreshold 2 -Denotes L-Series Outswing Threshold 3-Ni-Gam Outswing Threshold 4-W-1815 5-worldwide Pro T4 Threshold National Accreditation & Management
Institute, Ine./4794 George Washington Memorial Highway/11ay'es, VA 23072 Tel: (804) 684-
5124/Fax: (804) 684-5122 NAMI AUTHORIZED SIGNATURE:
L. Roberto Lomas P. E.
1432 Woodlord Rd.
Lewisville, NC 27023
Manufacturer: Masonite
Report #: 514012A
434-688.0609 Date: 10/10/2017
rllomasCaNdomaspe-com
Test Report: N/A
Product: Double Door with and without sidelites 12'x6'8" (composite frame)
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code.
Anchor capacity in shear condition:
Solid members w/ 6 w/out gap:
a. With threads present in shear plane
Fastener type: #10 wood screw
Nominal diameter: O: 0,190 in
Root diameter: Or: 0,152 in
Minimum required penetration: p: L140 in
Side member: PVC
Side member thickness: t,= 1000 in
Side member dowel bearing strength: Fu = 10,000 psi
Side member dowel bearing length: I, = 1,000 in
Mode 1. Mode I, Mode II
qm = 636.5 Ibs/in qs = 1900 Ibs/in A: 0,0005
P = 725.61 Ibs P = 1900 Ibs R: 1.07
Ko = 2,400 Ko = 2,400 C:-681.799
Z.= 302 Ibs Z,= 792 Ibs P = 510 Ibs
Ko = 2.400
NDS 2012, NOS 2015, TR12)
Gap: g: 0.0000 in
Moment orm: 0.0000 in
Screw bending yield strength: F,a = 80,000 psi
Main member: Spruce -Pine -Fir (G=0.42)
Main member thickness: t. = 1,500 in
Main member dowel bearing strength: F,,,, = 3,350 psi
Main member dowel bearing length. I. = 1.140 in
Mode III. Mode III, Mode IV
A: 000066 A: 000092 A: 0,00105
8: 0,57 8: 0.5 8: 0.000
C:-253,623 C 521,824 C -93.6
Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs
P = 324 Ibs P = 529 Ibs P = 299 Ibs
Min. Design value: Z= 125 Ibs Z= 212 Ibs Ko = 2A00 Ko = 2.400 Ko = 2,400
Duration Factor: Co = 1.6 Z= 135 Ibs Z= 221 Ibs Z= 125 Ibs
Allowable Design Value (ZCt,): Z.= 199 Ibs/anchor
Fastener type: 1/4 ITW Topcon Tabulated values
N.Q.A.16-1222.06
Substrate: Hollow block
Minimum embedment:
Actual edge distance:
Actual C To C spacing:
Allowable Design Value:
1.25 in
2,50 in
edge
distance
clog (in)
2.00 4.00
2.00 130 l61
4.00 163 202
3,00 in
Z. 155 Ibs/anchor (per interpolation when needed)
Fastener type: #10 Self topping screw (Calculations per 2615 Aluminum Design Manual, section J.5.5)
Nominal screw diameter: D: 0.190 in Screw root area: A, 0.0151 inn
Actual edge distance: de: 1.085 in Screw shear ultimate strength: F,,, 54.0 ksi
Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member material: Vinyl PVC Main member material: 6063.T5 aluminum
Thickness: t, 1.000 in Thickness: t, 0,052 in
Ultimate tensile strength: F,,,, 14 ksi Ultimate tensile strength: F,,,z 22 ksi
Nominal strength per bearing (side member): Rn = 20t,F, Rnl = 5320 Ibs (Eq J.5.12)
Nominal strength per bearing (main member). Rn = 2Dt?Fw2 Rn2 = 435 Ibs (Eq J.5-12)
Nominal strength per tilting: Rn = 4.2(t,"D)"F.u, Rn = 478 Ibs (Eq J.5-13)
Nominal screw shear strength: Rn = A,F,,,/1.25 Rn = 654 Ibs (Eq J.5-14)
Safety factor: o = 3
Allowable shear and bearing capacity: P. 145 Ibs/onchor
Fastener type: 910 Self tapping screw Calculations per AISI-5100-12, sections A2.3.2 and E4.3.1)
Nominal screw diameter: 0: 0,190 in Screw shear ultimate strength: F,. 54,0 ksi
Screw root area: Ar 0.0151 inn Per table J3.2 of 2010 Steel Construction Manual 14th Edition
Side member material: Vinyl PVC Main member material: Metal framing
Thickness: t, 1.000 in Thickness: t, 0.(—
Ultimate tensile strength: F„ j 14 ksi Ultimate tensile strength: F.E
Nominal strength per tilting: Rn = 4.2(t,'D)`2F„2 An: 1001 Ibs (Eq E4.3.1-1) R , L
Nominal strength per bearing (side member): Rn = 2.7Dt,F„ i Rol: 7182 Ibs (Eq E4.3.1-2 and -4) e • • • 'sy
Nominal strength per bearing (main member): Rn = 2.70tEF„z Rn2 = 1280 Ibs (Eq E4.3.1-3 and -5) C E N S+ (Pf.<e
Nominal screw shear strength: Rn = A,F,,,/1.25 Rn: 654 Ibs
Safety factor: 0= 3 4 • *' " Allowable shear and bearing capacity: P„ 218 Ibs/anchor e
s • .
m anMinimanchor capacity: 145 Ibs/onchoir A n F • j
Note: Anchors with the least capacity Is used for calculations to qualify anchors with higher capacity- 0 f1 4
10R
rQNALmilt i
1 of 4
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514012A
434-688-0609 Date: 10/10/2017
rI lOn1 a sCu)lriom aspe. com
Anchor calculations. minimum reouired anchors
36.38 36.38 Design pressure: 60.0 psf
F-A-1-77-A-1-71 T
AY 13 Y 79.25
AlAt At
72.75
37.50 36.38 36.38 37.50
Al A4 A4 Al
Y Y_ yY
Y Y
Y
Y
Al A4 A4 Al
79.25
147.75
Anchor Locations:
Zone
Area
2ft)
Load
Ibs)
Ind.
i^)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs) QtY
Load
Ibs)
Ai 2.3 138 N/A N/A 145 1 138 OK
A2 7.7 463 6.00 21.00 145 5 93 OK
Aj 7.7 463 N/A N/A 145 4 116 OK
Design oressure: 60 0 osf
Zane
Area
2ft)
Load
Ibs)
Ind.
in) O.C.
Anchor
ResultCap.
lbs) Q
Load
Ibs)
A, 2.4 146 N/A N/A 145 2 73 OK
A2 7.9 473 6.00 21.00 145 5 95 OK
A3 7.8 468 N/A N/A 145 4 117 OK
A4 2.3 138 N/A N/A 145 1 1 138 OK
AS 7.7 463 1 N/A N/A 145 1 4 116 OK
Double door
36,38
6.00 TYP. -- 6
I
i
L... F ——
6.00
I
MAX
O.C.
a_f____..
79.25
t__-
6.00
2of4
00 TYP. --- 18.19 TYR ---+-+
3.00 TYP. i ---
i
N " ,..,./lfq r1'•'`
r
C'EfVs''•''
7
a TAT OF
4t.7w
fv// 9ONAit.`
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E.
1432 woodtord Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514012A
434-688-0609 Date: 10/10/2017
rIIomasCa Irlomaspe.corn
Double door with sidelites
i.....-._..._ _.._ ..... 37.50 ...._ _ __ __. _._. 36.36 _.. __ ...,..... _._ 36.38 . _...._...._ ....._.___. ___... ... _ 37.50
4---- 18.75 TYP. ---•-I
6.00 TYP. + 6.00 TYP. .......+.+.- 18.19 TYP.
3.00 TYP. {......
i 6.00
i,
is,
MAX
O.C.
79.25
6.00
3of4
TAT OF .•<v o. r .'cZORVDt
ONAI.
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberta Lomas P. E.
1432 Woodford Rd.
Lewisville, NC 27023
434.688-0609
dlomasCaNdomasoe.com
Manufacturer: Masonite
Report #: 514012A
Date: 10110/2017 Installation Instructions: 1. FOR
ANCHORING THROUGH
FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO
ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE
ANCHORS AS SHOWN BELOW. 2. FOR ANCHORING THROUGH
FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE
A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE
ANCHORS AS SHOWN BELOW. 3. FOR ANCHORING THROUGH
FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH
TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 1/
2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW. 4. ALL FASTENERS TO
BE CORROSION RESISTANT. 5. INSTALLATION ANCHORS SHALL
BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS
SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE
MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC
GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE
STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED
BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL
18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI 052" THICK MINIMUM 6.
ANCHOR LOCATIONS SHOWN
IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE DESCRIBED PRODUCT EXPOSED AT
THE DESIGN PRESSURE INDICATED HEREIN, 7. WOOD FRAMING AND
MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO
STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD. 8. 1X BUCK OVER
MASONRY/CONCRETE IS OPTIONAL. 9. WHERE SHIM OR
BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH FRAME IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY
FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 10.
WHERE WOOD BUCK
THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE, UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD
BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 11. WHERE
1X BUCK
IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION
OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF
RECORD. 12. BUCKS SHALL EXTEND
BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED, 4of4 TAT OF
0
RtOP'
nol ALW
Luis R.
Lomas P.
E. FL No.: 62514 10/
10/2017
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville. NC 27023
Manufacturer: Masonite
Report #: 514008A
434-688-0609 Date: 10/10/2017
rllomas(alldomasRe. com
Test Report: N/A
Product: Double Door with and without sidelites 12'x6'8" (wood frame)
Scope:
This analysis provides calculations, quantities, and spacing requirements for installing product to substrate, and it applies only to the
product described herein. These calculations comply with requirements of the Florida Building Code.
Anchor capacity in shear condition:
Solid members w/ d w/out gap:
a. With threads present in shear plane
Fastener type: #10 wood screw NOS 2012, NUS 2015, TR12)
Nominal diameter: 0: 0.190 in Gap: g: 0.0000 in
Root diameter: Dr: 0.152 in Moment arm: 0.0000 in
Minimum required penetration: p: 1.140 in Screw bending yield strength: F,b = 80,000 psi
Side member: Douglas Fir -Larch (G=0.50) Main member: Spruce -Pine -Fir (65=0.42)
Side member thickness: t, = 1.000 in Main member thickness: tm = 1.500 in
Side member dowel bearing strength: F, = 4,650 psi Main member dowel bearing strength: F,,,, = 3,350 psi
Side member dowel bearing length: I, = 1.000 in Main member dowel bearing length: Im = 1.140 in
Mode I. Mode I, Mode II Mode III• Mode III, Mode IV
qm = 636.5 ibs/in qs = 884 Ibs/in A: 0.0007 A: 0.00096 A: 000107 A: 0.00135
P = 725.61 Ibs P = 884 Ibs 8: 1,07 R: 057 8: 0.5 8: 0,000
Ko = 2.400 Ko = 2.400 C:-427.674 C:-253.623 C: 267.699 C: 93.6
Z = 302 Ibs Z,= 368 Ibs P = 331 Ibs Ms = 46.8 in-Ibs Mm = 46.8 in-Ibs
Ka = 2.400 P = 297 Ibs P = 319 Ibs P = 263 Ibs
Min. Design value: Z= 110 Ibs Z= 138 Ibs Ko = 2.400 Ko = 2.400 Ko = 2.400
Duration Factor: Co = 1.6 Z= 124 Ibs Z= 133 Ibs 2= 110 Ibs
Allowable Design Value (ZCo): Z'= 175 Ibs/anchor
Fastener type: 1/4 ITW Topcon Tabulated values
N.O.A. 16-1222.06
Substrate: Hollow block
Minimum embedment: 1.25 in
Actual edge distance: 2.50 in
edge
distance
spacing (in)
2.00 1 4.00
2.00 1301 161
4.00 163 202
Actual C To Cspacing:
Allowable Design Value:
3.00 in
Z..= 155 Ibs/anchor (per interpolation when needed)
Fastener type: 10 Tek screw
Substrate: 18 GA, Steel
Tabulated design value: Z= 1266 Ibs
Safety factor: Fs= 4
Allowable Design Value (ZFs): Z'= 316 Ibs/anchor
Minimum anchor capacity: 155 Ibs/anchor
Note: Anchors with the least capacity is used for calculations to quality anchors with higher capacity.
Anchor calculations, minimum required anchors
36.38 36.38 Design pressure: 60.0 psf
Al Al r
AzY - YAz 79.25
I
l
72.75
37.50 36.38 36.38 37,50
At
Y A3
Y
A4
Y AS
A4
Y A3
Al
Y
A3 Y A5
Al
147.75
1 of 4
79.25
Zane
Area
2ft)
load
Ibs)
Ind.
i^)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs)Qty
load
Ibs)
Ai 2.3 138 N/A N/A 155 1 138 OK
A2 7.7 463 6.00 21.00 155 5 93 OK
A3 7.7 463 N/A N/A 155 3 154 OK
Design pressure: 60.0 psf
Zone Area
2ft)
Load
Ibs)
Ind,
i^)
Max.
O.C.
in)
Anchor
ResultCap.
Ibs)
Load
Ibs)
Al 2.4 146 N/A N/A 155 1 146 OK
A2 7.9 473 6.00 21.00 155 5 95 OK
A3 7.8 468 N/A N/A 155 4 117 OK
A4 1 2.3 1 138 N/A N/A 155 1 138 OK
A5 7.7 463 N/A N/A 155 3 154 OK
TAT Q F
0R101: • 1'•,
70NAL771ltt(iti
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P.E.
1432 Woodford Rd. Manufacturer: Masonite
Lewisville, NC 27023 Report #: 514008A
434-688-0609 Date: 10/10/2017
dlornasCcillrlornaspe.corn
Anchor Locations:
Double door
79.25
2 of 4
6.00 TYP. r--
6.00
6.00
36,38 36.38
6.00 TYP. 18.19 TYP. —
3,00 TYP,
P. - LN•
No
TAT OF
0
is
0e
4.
ip
0N Al.
tlltt
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E.
1432 Woodford Rd.
Lewisville. NC 27023
Manufacturer: Masonite
Report #: 514008A
434.688.0609 Date: 10/10/2017
rIIomas(d-)Idomasoe.com
Double door with sidelites
37.50 ... _.. ..__.._......- _. __.. 36.38 36.38.. _.. .. -'*" __.. _. _..__. 37.50
18.75 TYP.
i
6.00 TYP -- --, 6.00 TYP. ..___..,.._._ 18.19 TYP....
i
3,00 TYP ---+ i
79.25
6.00
3of4
1 , • • • /
1
wTATOF
F• lORtaP •-\
QNAL '`
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
L. Roberto Lomas P. E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
r1lomas0lrlomaspe.com
Manufacturer: Masonite
Report #: 514008A
Date: 1011012017
Installation instructions:
1. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 112"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
2. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
3. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE 410 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN BELOW.
4. ALL FASTENERS TO BE CORROSION RESISTANT.
5, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PS1 MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (048") FY=33KSI/FU=52KSi OR ALUMINUM 6063-T5 FU=30KS1
052" THICK MINIMUM
6. ANCHOR LOCATIONS SHOWN IN THIS DOCUMENT ARE THE MINIMUM REQUIRED FOR THE
DESCRIBED PRODUCT EXPOSED AT THE DESIGN PRESSURE INDICATED HEREIN.
7. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY
OF THE ARCHITECT OR ENGINEER OF RECORD.
8. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
9. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" UNITS MUST BE ANCHORED THROUGH
FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER
STRUCTURAL SUBSTRATE MATERIAL.
10. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. UNITS MAY BE ANCHORED THROUGH
FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS.
11. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
12. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
4of4
Luis R. Lomas P.E.
FL No.: 62514
10/10/2017
MASONITE.
314-LrTE FIBERGLASS "R UNIT
6-8"DOUBLE DOOR WITH / WITHOUT SIDELITES
Q N )TFC
1. EVALUATED FOR USE IN LOCATIONS ADHERING TO
THE FLORIDA BUILDING CODE AND WHERE PRESSURE
REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM
DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES,
DOES NOT EXCEED THE DESIGN PRESSURES LISTED.
2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ).
HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS. REQUIRED,
3, WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION,
HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED.
4. POLYURETHANE CORE FLAME SPREAD INDEX OF So
AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84.
PLASTICS TESTING;
TEST DESCRIPTION DESIGNATION FACING UTE FRAME
SELF IGNITION TEMP ASTM D1929 1 752 -f > 65) 'F B42 'F > 850'F
RATE OF BURNING RSTM D635 1 0.56 IN4 1.28 MININMIN
LSMOKE DENSITY I ASTM D2843 53.4%
LtN:S::ILr STRE.GT.--T. M38 12%Dllf
PLASTICS TESTING OF WORLDWIDE COMPOSITE FRAME (WHERE USED}
TEST DESCRIPTION DESIGNATION RESULT
SELF IGNITION TEMP ASTM D 1929__ 779 :F > 650 -F
RATE OF BURNING ASTM D635 1 0.0 IN.
SMOKE DENSITY ASTM D2114.3 1 39.01
LENS!LE STRENGTH* ASTM
COMPARATIVE TENSILE STRENGTH AFTER WEATHERING
4500 HOURS XENON ARC METHOD I
149 - WK. OVERALL FRAME WIDTH
21 - MAX .36 375" MAX. 21" MAX
UL.D. PANEL WIDTH D.L.D. 37.5' MAX.
WIASTRAGAL i FRAME WIDTH
o
El 11Elfl
SCALE N.T.S.
w, _sr: SW!
KURT BALTHAZ R
FLORIDA P.E.
56533 DWG-MA-FLOt9d
swo I OF
31
SEE DETA
C*
3.
8 x 2"
8 x 2'
T
N5WING THRE LH=
Ka
10 x 5/8-
10 x 5/8"
10 x
10 x 2-112
10 x 1"
10 x 518*`
Q L "
0.962"j
C73L---..
T
BUMPER Ol/S--jtjRE5±DLD
O
SEE DETAIL_
cx
6'
D-UAIL
ATTACH ASTRAGAL RETAINER BOLT
STRIKE PLATE TO FRAME
AS SHOWN,
I I I
1.482" 1. 75" j1 0.7 1.437"fj
T T T
Z-SERJES Q45-LHf?E5hoL) I blQd-DAM--Q/S THR SHO T4 QZS IdU—SHOLD
EE DETAIL
C"
6-
ASTRAGAL RETAINER BOLT HOLE
MUST BE DRILLED THROUGH
THE THRESHOLD & INTO THE
STRUCTURE DEEP ENOUGH
FOR A 1,375" THROW
DETAIL "E" ASTRA
DASMM V.WtDM
emcee2 An=
TYPICAL 21.62ING
NQN-IMPACT CLASS
Do
N. T. S.
sws
11C 140,
MA-r,0;93-
F 01-3
SEE DETAIL
C' SHT. 2
8UACbMj-NT QIL ET& 1.
ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED
AND SEALED BY ROBERTO LOMAS, PE FLORIDA #
62514) WITH THE LOWEST (LEAST) FASTENER
RATING FROM THE DIFFERENT FASTENERS BEING
CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD
FASTENERS ANALYZED FOR THIS UNIT INCLUDE 10
WOOD SCREWS, 1/4- TAPCONS, AND #10 TEK SCREWS. A
PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR
LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2-. WOOD
SCREW EDGE DISTANCE MIN 3/4-. TEK SCREW EDGE DISTANCE
MIN 112-. 2.
ANCHORING INTO STEEL STRUCTURE MUST BE SUFFICIENT TO ACHIEVE
3 THREADS MINIMUM BEYOND STEEL INTERIOR SURFACE 3"
R
A - --,- H --DU l -F 1.
KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES
980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT
5-1/2- CENTERLINE. 1.
25 2. 4" X 4" FULL MORTISE BUTT HINGES. MIN0.25 — r--------
1-Xl/2- CORRUGATED #IOX2- WOOD SCREW HIM1,
25' 3' FROM EACH END 6" FROM EACH END MIN
AND 7" DC AND 12" OC 0,
25' MAXSMJi TYPICALMASONRY
CL All HIM
AC%C —1 1-
1 CAULK 1 ACRYLIC
ANCHOR INSTALLATION
LATEX LL—t— CAULKCL 3. THE
WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&
PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-
112" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT
OF 1-1/4-. 4. WOOD
BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS
TO STRUCTURE. 5. MINIMUM
DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. T 7t
1XSUCK
MASONRY COMBINATION WOOD COMBINATION WOOD 7- 1 1,
50
1. - -
I ANCHOR
INSTALLATION MULLION (BOXED) MULLION (BOXED) MIN 1_ 651; --
LAI — O25" MAX SHIM CLTYPICALWOOD
BUCK
ANCHOR INSTALLATION 30&
OX2-1/
2" 0 SCREWS EACHENDINTEGRAL
WOOD MULLION (
CHS) 4
lOX2-1/
2- D SCREWS EACH
END ii
INTEGRAL WW
MULLION (
CHS) 17
N.T.
S.
s Sl cw,
sy" OF