HomeMy WebLinkAbout2334 Tudor Rose Dr 18-3523 SWIMMING POOLAUG 16 2018CITY OF SANFORD BUILDING & FIRE PREVENTION PERMIT APPLICATION Application No: Documented Construction Value: S 63,000.00 Job Address: 2334 Tudor Rose Dr. Sanford, FL 32773 Historic District: Yes No Parcel ID: 17-20-31-5VC-0000-0190 Residential Commercial Type of Work: New X Addition Alteration Repair Demo Change of Use Move Description of Work: Installing In -Ground Gunite Swimming Pool Plan Review Contact Person: Shawn Fred Phone:407-366-4600 Fax:407-359-1916 Title: Permitting Supervisor Email: Shawn@AtlaspoolsofcentralFL.net Property Owner Information Name David & Keri Jensen Phone: 407-902-8507 Street: 2334 Tudor Rose Dr. City, State Zip: Sanford, FL 32773 Resident of property? : Contractor Information Name Atlas Pools of Central FL (Bruce Wemple) Phone: 407-366-4600 Street: 3024 Kananwood Ct. STE 1016 City, State Zip: Oviedo, FL 32765 Name: Street: City, St, Zip: Bonding Company: Fax: 407-366-5023 Yes State License No.: CPC1457252 Architect/Engineer Information Phone: Fax: E-mail• YV Mortgage Lender: Address: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has P commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code 1 N Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance ofpermit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I ::k (of l°IlIt Sigl " ture tier/,A((ent Date O AVI 0 Print Owner/Agent's Name Signature of KIENNETH M LAUVER III MY COMMISSION # FF235363 EXPIRES June 20, 2019 14C/1.34L-0'S3 FlOfdaNO'YSC:CICC.:AAr_- Owner/Agent is Personally Known to Me or Produced ID Type of t4cerige- Signature of Contractor/Agent Date Print Contractor/Agent's Name cp/gIle Signature of Notary -State of Florida Date tKENNETH M LAUVER III MY COMMISSION # FF235363 EXPIRES June 20, 2019 40I) 3W-0'03 Flordallo[a' c^;ico.cwr Contractor/ Agent is 7 Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: Ae UTILITIES: ENGINEERING: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: SF 4 -1 (- t $ COMMENTS: OK fo Cy.+J ruc an / - 4 _ sa/.r a+;n-+Oa01 a1 en jJ/sy . Revised: June 30, 2015 Permit Application DocuSign Envelope ID: A75B751A-E499-4D96-9182-E32EC75F32C4 RECORD COPY JOB NAME J Jensen, LOCATION MAP SX8 6" TD 6 SR 6 RB 6 SR er T T' i pth Std Depth Swim Out REVIEWED FOR CODE COMPLU PLANS EXAMINER DATE A PERMIT ISSUED SHALL LICENSE TO PROCEED W11 AUTHORITY TO VIOLATE, ASIDE ANY OF THE PROVI; CODES, NOR SHALL ISSUAI THE BUILDING OFFICIF j REQUIRING A CORRECTIC CONSTRUCTION OR VIO i HOMEOWN11 ERSAESPONSIBILITIES: PRIOR TO START OF CONSTRUCTION ALL LANDSCAPING-, SPRINKLER SYSTEMS, AND ANY ATLAS POOLS OF CENTRAL FLORIDA.° INC. UNFORESEENSTUMPSINAREA&M ACCESS AND POOL CONSTRUCTION MUST BE REMOVED BY HOMEOWNER...IF POOL IS TO 3024 KANANWOOD CT., SUITE 101fi, OVIEDO, F- HAVEAGASHEATEROFANYTYPE, ARRANGE FOR DELIVERY OF STORAGE TANKAND OR HOOKUP IS THE RESPONSIBILITY AND 407)`273-4600 (407) 366 02765 234600Fax (407) 36CPCi EXPENSEOFTH'EHOMEOWNER...AS IS ANY.RESODDING OR LANDSCAPING. AFTER THE CONSTRUCTION DEPARTMENT. COMPLETES AN AND ASSESSES THE -SITE, SOME CHANGES" MAY BE WEB SITE: h1:10 /1 +rww.atlaspoolsofcentralfl.com CPC1457252 INSPECTIONREQUIRED. ( I.E. RETAINING WALL DUE TOSLOPE OF YARD, HOUSE SETBACKS, AND UTILITY EASEMENTS). POOL CONTRACT PRICE WILL THEN.BE ADJUSTED ACCORDINGLY IF ANY ADDITIONAL IS REQUIRED. HOMEOWNER/HOME BUILDER IS RESPONSIBLE FOR POOL: MAX. WIDTH: is FT. MAX. LENGTH: 35 FT DEPTH 3.5 TO 7 HAVING DECK TREATED FOR TERMITE PROTEGTIONAFTER DECK HAS BEEN FORMED, POOL: SURFACE.AREA: _482 SOFT. PERIMETER: 91 LF FINAL PLACEMENT OF MAIN DRAINS, .SKIMMER, RETURNS, DECK=O-DRAIN, AND EQUIPMENT TBD BY -ATLAS POOLS. SPA: SU:RFACE.AREA:: 3 SOFT: PERIMETER: LF ANY PREVIOUS :DRAWINGS:, SKETCHES, PICTURES OR.3-D RENDERINGS SHOWING POTENTIAL POOL PROJECT$ ARE VOID, PREP WORK EXCAVATION TYPE: 8ft Access DECKING TYPE: Paver SF IT IS :UNDERSTOOD: BY THE HOMEOWNERS T WHEN PURCHASING BOTH A SPAAND A SEPARATE WATER FEATURE FOR THE REMOVALOF DIRT. Yes TOP EXISTING: I 242 SF POOL, THAT BOTH O'FTHESE WILL NO N AT THE SAMETIME UNLESS YOU PURCHASE A _SECOND PUMP/MAIN DRAIN MISC. OTHER. - aF ITEMSSYSTEM TO OPERATE THEM INDEPENDEN I L_ REMOVALQFSTUMP'S: # SIZE: DECK-.O-,DRAIN: 42 LF IT IS UNDERSJ.TOODBY THE HOMEOWNERS THAT WHEN.YOUARE INSTALLING YOUR_OWN WINDOW/DOORALARM, • fLD SAFETY F LOADS._ REMOVALOFCONCRETE. 5- `` ' FE. NGETO BE REMOVED BY._ FOOTERS YES N O wa' 15 FENCING, OR YARD FENCE FOR THE CHILD SAFETY REQUIREMENTS, THAT THESE MUST BE DONE TO CODE AN IOR TO THE FENGETa BE REPLACED BY: " SIZE. azasw®sa ianzri4ar _ LF POOL COMPANY APPLYING THE POOL FINISH TO YOUR POOL. ATLAS POOLS NOT'TO BE LIABLE FOR THESE ITEM STRUCTURAL - WORK TURNDOWNS. 6" 225 LF 12" 3 LF 45' - 6' Round Spa. ANGLE OF REPOSE' ENGINEERING: Yes 18' LF 24' LF 13' 3' 15r 4 Tfierapy JetS BEAM SIZE: e" _ STEP RISERS: 6 LF 10 4 LF IV, TD 6" TD 12)12 Footer Color Blobritd Light RAISED BEAMS 18 LF 24'- - LF Bubbler fi" LF 12" LF 18" LF 24" LF CANTILEVER TOTAL): -- LF 6 SR aft Gfanite SpiiiWay OTHER EDGE: Bdck Bull•;Nose Coping 181 LF Spa Air BIOWei' SUNSHELF SHALLOW ' END: 1ITSTEP: N/A - 9- STEP: -Yes COLOR BAND: YES NO: - BUBBLER? N/A ANCHOR. N/A EQUIPMENT & ACCESSORIES 6 RB ( t OTHER LOCATION AND DEPTH: - - Pentair CCRP 200 FILTERSIZE:. 02RBMAINPUMP. P8f1 j1nteniFlo'VSF_ '3 HP u n STEPS I SWIMOUT OVER so LF[ -LF ADDTL PUMPS: 48" Sheer Witerfall Bench I x8 Footer ADDITIONAL BENCH: LIGHTS: 4 y TYPE co6_cbomar TILE. STD INATERUNE-(6' X61 EDGETILE`YES NO— En 12 SR DECO TILES: CHLORINATORnit"nn eenlChlai1C40 i +12 RB iI?COLOR: POsINTERIOR. FINISH. 0-81. iie, BPien CONSTRUED TO BE A THE WORK AND NOT AS ANCEL. ALTER OR SET NS OF THE TECHNICAL E OF A PERMIT PREVENT FROM THEREAFTER OF ERRORS IN PLANS, tTIONS OF THIS CODE 3.6' Color Globrite Light Paver Deck. Thick Pavers On Lanai Homeowner Providing Window.&Door:Aiarms iaUif_p QANFO,O 18-3523 Bond. Beam THERAPY SPA' HEAT PUMP wn Brick Bull Nose 8 OUTSIDE 24 SIZE ' SF SOLAR PANELS #- SIZE AUTO Coping S: BENCH, & # s JETS rRETURNI WATERFEATURES; Std. Depth Steps & Sunsheff FOR SPA: FLOOR:. YB`' WALL _ 48^ Sfie_er'WatedallSun Shelf Second Ste P BRAND: PO"" - TYP.E'Goh"0 -- SAFETY'FENCE: LF DAM WALL: e FT. SPILLWAY* "WIDE POOUSPA CONTROL:.- Eaytouch Sceen Lola FENCE.IS. PAVERS.. DIRT —AUTO GATE. YES NO_ WINDOW/DOOR ALARMS BLOWER, Y84HEATER: PROPANE Yes BTUS 460k TOTAL•GALLONAGE-POOLAPPROX: 12245' NAT. GAS BTUs TOTAL GALLONAG&SPA APPROXi a7a__ PLUNIBINd RUN POOI t / SPA_ 40 ELECTRIC RUN ( METER TO EQUIP) 30 - -• LF I DS ._ BUYER PLEASE INITIAL- BUYERS APPROVE THE ABOV SPECIFICATIONS s PentairVS .3hp.: Pump Perltedr266 C• F,Ilter AND.EQUIPMENTLOCATION: I Intellichidir ic4o PFIEPARED By..Brad Ghambeis EXCLUSIVELY FOR: wag $ N I EAsyioUdh 4 Screen NAME. David & Ken, -Jensen o ; Logic Controls 2334 Tudor Rose Dr. Sanford 32773 CITY: ZIPADDRESS: yIdIaStertemp. 40Qk HOME PHONE: 407=901-8507 yyORK: C€I I Propane GaS Heater EMAIL; davidllensen@atLnet I Auto Valve For Waterfall Cit Of Sanford I Spa Air' BIQWei PERMIT TO BE SECURED FROM' j LOT 19 BLOCK: 81 SUBDIVISION. Kensington Reserve PLAT BOOK: oB 1fs iad yc_ `PR OF. ABM 777 6/20/2018 I :14 PM CUSTOMERS SIGNAUR DATE: 40DA32CBD74B431... Scale: 1/ 5" = 1 ft. CUSTOMERS SIGNATURE: DATE` _ 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. GENERAL NOTES For pool plan, size, deck, and special details, see Contractor's Pool Plan. Pool Walls shall be 5" thick and Floors shall be 6" thick and shall be pneumatically applied Concrete with a Compressive Strength of 3,000 psi in 28 days. Concrete`< Decks shall be 2,500 psi. Concrete construction will conform to ACI Standard 318. All Pool design, construction and workmanship shall be in conformity with the requirements of Florida Building Code, 6th Edition, 2017 (FBC) Accessibility; FBC Building; FBC Residential, and; ANSI/APSP/ICC-3, ANSI/APSP/ICC-4, ANSI/APSP/ICC-5;ANSI/APSP/ICC-6 and ANSI/APSP-7; ANSI/APSP-15 and the Adopted National Electric Code 2014 (NEC) and Chapter 42 and Chapter 45 of the Florida Building Code, 6 th Edition, 2017, Residential. All Pool Piping to be Schedule 40 PVC, bearing the mark of NSF Approval unless otherwise noted. All Reinforcing Steel to conform to ASTM 615, Grade 40. Reinforcing shall be #3 bars at 12" on center in each direction, w/ 15" lap joints in walls and floors up to 6'. Where the pool depth is over Eft (measured vertically down from the Waterline), use #3 bars at 6" on center in each direction in the areas that exceed Eft in depth. 6" WATER COPING WAI R LINE TILES POOL LINE ,', DRAIN COVER/GRATE VtTl STEPS X w 5 MUST CONFORM TO POOL THE LATEST EDITION w LIGHT OF ANSI/ASME Cnn 112.19.8 POOL STEPS: ' '`'- RISERS: 12" MAX. DUAL SUCTION OUTLET AND APPROVED GRATE TREAD: 10" MIN. (240 SQ. IN. MIN.) WITH 3'-0" OF SEPARATION CENTER LINE TO CENTER LINE OR APPROVED CHANNEL DRAIN POOL SECTION SETPOOLSTO CENTERETTRPOF OINT STEEL GRID AT THE LONGITUDINAL) CONCRETE DECK (OPTIONAL) W/ SLIP RESISTANT TOPPING ON COMPACTED GROUND W/ ALL ORGANIC MATERIAL REMOVED. 4" NOM. THK. W/ FIBER MESH OR 5" NOM. THK. W/ #3 REBARS. WATER LINE 14" MIN. N 18" MAX. UNDISTURBED S01 LS NO VOIDS) SWIM - OUT DETAIL DECK OVER POUR OR 8 ") BRICK COPING If Concrete is cast against Bare Earth without a Separation Barrier, the minimum 1-#3 BAR CONT. IN 5" THK WALL. 4'-0" JUNCTION BOX cover shall be 3". With a Barrier (Steeltex) between Concrete and Earth, the USE 2-#3 BARS CONT. IN 8"x8" BY OTHERS) WAT R minimum cover shall be %". BOND BEAMS) LINEAll A. MetallicPoolFittingswithin5' of the inside wall and deck reinforcing steel to be asTO TRANSFORMER6„O 1-#3 BAR to the Pool Reinforcing Steel with #8 AWG Copper Wire. The #8 Copper WATER LINE BY OTHERS) WATEbonded C2BARIIN5" Wire to be run internally and externally with the NEC approved PVC Light Conduit z oz LINECONT. MIN. THICK BOND form the Light Niche to the Junction Box. Completion of the pool grounding to the TILBEAM Electrical Panel Ground to be by Electrician. Bond all Sheathed Cables, Raceways, Metal Piping and all Fixed Metal Parts not separated by a permanent barrier, if within 5'-0" Horizontally from Water andMARBLE U.L. APPROVED 120 VAC/30OW POOL12'-0" Vertically of Maximum Water Level. PLASTER LIGHT W/ GFI OR 12V/40OW MAX. POOL 1Y2" COVER Equipotential Bonding to be accomplished in accordance with Article 680 of the FINISH LIGHT W/ LOW WATER CUT-OFF IN U.L. OVER ALL BARS Adopted National Electrical Code 2014 (NEC). APPROVED GREY PLASTIC FORMING SHELL SEE NOTE #5) Pool or Patio shall bear only on Rock or Clean Sand, which shall be compacted to OR APPROVED EQUAL W/ #8 AWG BOND provide a Structurally Safe Bearing Capacity. Any Unsuitable Material encountered in WIRE PER N.E.C. ALTERNATE BEAM excavation shall be removed in its entirety and the area shall be backfilled with acceptable material and properly compacted. Where unsuitable Material cannot be STEELTEX ( OPTIONAL) 3 BARS ® 12" O.C. EACH WAY FINISH DETAIL removed, the pool must be redesigned. POOL STRUCTURAL DETAILS TheContractormustprotectExistingStructuresfromfailurebyacceptablemethodsDISTANCE LESS NEW OR if required, The Engineer accepts no responsibility for the safety of Existing VARIES 18" THAN 1 ON 1 1 EXISTING Structures, The Design Engineer assumes no responsibility for pool construction in Easements or COPING SEE SEAT STRUCTURE iiii Required Setback areas. Pool Contractor and/or Owner shall verify the layout and WATER PLAN all dimesions shown prior to construction. LINE 12. Contractor shall determine the location of all Utilities in relation to the Pool and its 5 EquipmentandensureminimumclearancesinaccordancewithLocalRegulationsTHERAPY and Ordinances. LINES 13. Contractor shall provide adequate Temporary Fencing around the construction area o0 4" to prevent unauthorized entry into the Pool Area. RETURN 14. If a water supply is provided, a minimum 3" Atmospheric Break will be provided. io LINES 15. All Structural, Filtration and Electrical details outlined in these drawings also relate GUNITE to Spa Construction. #3 BARS ® REBOUND 16. All Pool and Spa Heaters shall be equipped with an On/Off Switch mounted for 12" O.C.E.W. 2) 8"0 ANTI -VORTEX easy access to allow the Heater to be Shut Off without adjusting the Thermostat DRAINS SEPARATED BY 3' settings and to allow restarting without relighting the Pilot Light. 17. WARNING! To empty the Pool for any reason, the Hydrostatic Uplift Pressure must SPA STRUCTURAL DETAILS beeliminated. The Owner must consult a Contractor experienced in eliminating Uplift Pressure. 1 MAIN DRAIN LINE 2 SKIMMER LINE E3WASTELINED 3 4 RETURN LINE 5 PRESSURE CLEANING CLINE (OPTIONAL) A HAIR & LINT STRAINER 5 B B RECIRCULATION PUMP 4 C FILTER A D IN -LINE CHLORINATOR OPTIONAL) E HEATER (OPTIONAL) FIL TER SYSTEM SPILLWAY PER CONTRACTORS POOL COPING-* PLAN 3 BARS ® 6" O. C. EACH WAY 6" WALL - THICKNESS MARBLE — PLASTER FINISH TYPICAL WALL AND FLOOR WITHIN 6x6 GLASS -BLOCK ANGLE OF REPOSE MOUNTEDIN2.500 psi CEMENT ( IF SPECIFIED) WATERLINE TILES INTERIOR POOL FINISH 3 REBAR 0 12" O. C.E.W. RAISED SPA DETAIL CONTRACTOR MUST PLACE L STEEL IN THE POOL WALL AT NO MORE THAN ..ON CENTER IN BOTH DIRECTIONS IN THIS CR CAL AREA. ALSO THE POOL SHELL WALL SHALL CONSTRUCTED TO 6" THICKNE THE STEEL MAT/ANTHICKER SHELL WALL SHALL EXTEND ALONG RITICAL AREA AND TO A POINT WHICH IS GR HAN THE MINIMUM REQUIRED AS DETERMINED THE 1 ON 1 + 1 METHOD. PLAN EXPIRES 1 YEAR FROM THE SIGNATURE DATE OR THE EFFECTIVE DATE OF A MAJOR FLORIDA BUILDING CODE CHANGE WHICHEVER IS SOONER JULY 09 2018 Date ALailongineering Services, Inc. rry 13. Schnaper, P.E. FL: PE NO. 32046 2431 Aloma Ave., Ste. 124 Winter Park, FL 32792 4. 07) 275-1099 LADDERS ARE TO BE CROSS BRACED PER MANUFACTURERS SPECS S. S. LADDER -,---.I ESCUTCHEON PLATE 1//-DECPOOL KWATER LEVEL EXPANSION SLIP RESISTANT JOINTS AS WEDGE REQUIRED TREADSURFACEANCHORADDITIONAL CONCRETE AS REQUIRED FOR 3" MIN. TO 6" MAX STURDY INSTALLATION BETWEEN TREAD 8 BARE, SOLID, COPPER AND POOL WALL RUBBER tom CONDUCTOR TO SHELL BUMPER REINFORCING TYPICAL LADDER DETAIL c f #8 AWG COPPER WIRE TIME TO SERVICE CLOCK SPST TOGGLES I W. P. 1 4'- SWITCH DISC. I JUNCTION 12V POOL BOX TRANS. DECK R ALL ELECTRICAL WORK SHALL CONFORM WITH ART. 680 OF THE VWATER12INY2" LATEST ADAPTED NEC. CONDUIT OW MAX. POOL LIGHT W/ LOW CUT- OFF OR 120 V.A.C. W/ GFI PER NEC, ELECTRICAL DIAGRAM 1016 Kananwood Ct w Oviedo FL 3.2'7fi5 407) 3,66-4600 CK1457252 Swimming Poo/ Specification For: DAVID JENSEN 2334 TUDOR ROSE DR SANFORD FL 32773 I TURNDOWN NOTES i COMPACTED CONCRPOOL DECK 1. Detail is based on NO surcharge behind the Turndown and the Ground away from SUBGRADE the Turndown is Level (>4 to 1). Turndown may abut Ribbon Footer and be tied into Footer if Appropriate, with #3 Rebar. ' C 2. Turndown shall bear on Rock, Clean Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling 1-#5 BAR CONTINUOUS or Shifting. 1-#3 BAR CONTINUOUS 1-#5 BAR VERTICALLY AT A" ON CENTER 4- co z 3. All Reinforcing Steel is to Conform to ASTM 615, Grade 40. 8 r 4"0 CONCRETE PILASTER i ---- 4. Concrete shall contain Fiber Mesh and have a 28 Day Compressive Strength of AT 5'-0" ON CENTER WITH 2,500 PSI. 1-#3 BAR VERTICALLY 5. All Construction to Conform to Florida Building Code, 6th Edition, 2017, FBC — Building and FBC Residential. 6. Refer to Contractor's Plan on file with the Building Department for Details on --- Turndown Location. 7. If the Base of the Turndown does not extend into the Old (Existing) Ground, a 4"0 Pilaster will be required every 5'-0" that will be either 2'-0" into the Ground or to 6" into the Indigenous Material, Whichever is Deeper. The Pilaster will have a 3 Rebar tied into the #5 Rebar in the base of the Vertical Pour. 8. A Deck Turndown is NOT intended to be a substatute for a Retaining Wall. If the Vertical Dimension from the Top of the Concrete Deck to the Old (Existing) Ground reaches 36" for a 6" Turndown, 42" for a 12" Turndown, 48" for a 18" turndown, 54" for a 24" Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown should not be used. 9. For a Paver Deck, if the Vertical Dimension from the Top of the Deck to the Old Existing) Ground reaches 24" for a 6" Turndown, 30" for a 12" Turndown, 36" for a 18" Turndown, 42" for a 24" Turndown, for more than 20% of the Turndown Length or the Finished Grade Slope exceeds (steeper than) 4' Horizontally and 1' Vertically, a Turndown shall not be used. 10. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must coordinate Design and Construction of the Turndown Requirements with the Screen Contractor to Ensure it meets their Requirements. FOOTER NOTES 1. If a Screen Enclosure is to be installed, the Swimming Pool Contractor must Coordinate Design and Construction of any required Footer with the Screen Contractor. 2. Footer shall bear on Rock, Sand or Structurally Sound Soils (>1,500 PSF) that shall be compacted to provide Optimum Bearing Capacity and prevent Settling or Shifting. 3. Concrete shall have a 28 Day Compressive Strength of 2,500 PSI with Fiber Mesh or 6x6-10x10 W.W. Mesh. 4. (3) #3 Rebars is Equivalent to (1) #5 Rebar. 5. A Footer may be installed with a Brick Paver Pool Deck if required by the Jurisdiction or at the Option of the Contractor and may be placed over the Top of the Footer or Abutting the Side of the Footer. BRICK PAVER POOL DECKPROPOSED FINISHED GRADE n. I- it 11= X CONCRETE PAVERS ON CONCRETE DECK CONCRETE DECK MAY BE CONSTRUCTED WITH A FOOTER PROPOSED FINISHED GRADE (COMPACTED) 4 MIN. 1 Ni rEXISTINGGRADE z I I=111I- CONCRETE DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK iI GRADE NO FOOTER COMPACTED PAVER BRICK PAVER BASEe•MATERIAL• POOL DECK D' COMPACTED SUBGRADE ' 1-#5 BAR CONTINOUS 8" 4"0 CONCRETE PILASTER AT 5'-0" ON CENTER WITH1-#3 BAR VERTICALLY 1-#3 BAR CONTINUOUS 1-#5 BAR VERTICALLY AT 36" ON CENTER A = 6" to 24" a B= Y4 x A (4.5" to 18") PROPOSED FINISHED GRADE (COMPACTED) m 4 4 MIN. 1 in oI EXISTINGrGRADEAll _ R z 11-11 - 6 4" PAVER DECK TURNDOWN PROPOSED CONCRETE FINISHED POOL DECK GRADE r7 O g" I 1-#5 BAR CONTINUOUS 8" x 8" FOOTER CONCRETE CONCRETE FINISHED FINISHED PROPOSED POOL DECK PROPOSED POOL DECK GRADE R GRADE R I I • • , • —III- —I I ,' ° " I— I I 12" 2-#5 BARS ° 2-#5 BARS CONTINUOUS 12" CONTINUOUS I-^nri-n • n» _ _ nrnn°rrn BRICK PAVER 20POSED POOL DECK FINISHED GRADE _ N II —III - 2-# 5 BARS 12" CONTINUOUS 12" x 12" FO0TER WZ PA VER DECK OPTIONAL EDGE BRICK PAVER RESTRAINT PROPOSED POOL DECK FINISHED GRADE I- 1 1 1- COMPACTED COMPACTEDPAVERBASESUBGRADEPAVER DECK WITHOUT FOOTER OPTIONAL- CONCRETE OR PLASTIC EDGE RESTRAINT MAY BE ED TO THE DECK PERIMETER AS NEEDED TO SECURE PAVERS BRICK PAVER 20POSED POOL DECK FINISHED GRADE r, i 1=1 11= g" I 1-#5 BAR CONTINUOUS PROPOSED FINISHED GRADE - R 8" x 8" Fc W1 PA VER BRICK PAVER POOL DECK 12" 2-#5 BARS CONTINUOUS 8" x 12" FOOTER W/ PA VER DECK JULY 09 2018 ilo` Engine6ring Services, Inc. Larry: B. Sch'naper, P.E. FL , PE ,# 32046 2431 Aloma Ave. Ste 124 Winter' Park, FL 32792 Office: ,( 407) 275-1099 BRICK PAVER POOL DECK SEE PAVER DECK TURNDOWN DETAIL FOR INFORMATION NOT SHOWN PAVER SECURED TO TOP OF TURNDOWN BY PAVER INDUSTRY STANDARDS ALTERNATE PAVER ON TURNDOWN DRAINAGE SWALE- A - a A = 6" to 24" B = - x A (4.5" to 18") 1-# 3 BAR CONTINUOUS 1-# 5 BAR VERTICALLY D' AT 36" ON CENTER 1-# 5 BAR CONTINUOUS BRICK PAVER D' POOL DECK D COMPACTED PAVER BASE MATERIAL 8" COMPACTED SUBGRADE ALTERNATE PAVER LOCATION 1016 Kananwood Ct Oviedo FL 32765 407) 36-6-46M CPC1457252 Swimming Pool Specification For: Scale: None DAVID JENSEN 2334 TUDOR ROSE DR SANFORD FL 32773 DESCRIPTION AS FURNISHED; Lot 19, KENSINGTON, RESERVE, as recorded in Plat Book 81, Pages 86 through 92, Public Records of Seminole County, Florida, PLOT PLAN FOR / CERTIFIED TO: Ryan Homes/NVR Inc, TC, l.BTO Water LOT 18 ACT C D INAGE AREA N 9°48'54" E 60.00, 10.00' 18.7' 21,3' ).Do' M LANAI 21.3' PROPOSED MODEL Ul SANTA ROSA — B 2 CAR GARAGE RIGHT I ..., 'C W\MORNING RM. W/LANAI 10.00' F-- 18.7' / ENTRY 10,00' I 17 16' DRIVE 32.84' 25,50' 25,50' 26,17' 10' UTIL IESMT ' 4' CONC S/W CURE3 ....... \ 13'B-)S 8904.854)) TV 60, 00' TUDOR ROSE DRIVE 50' PRIVATE RIW) 7. S1 Ta- T>eck- 1 Qi •-i I To Wtx4er Pao Eq . O 0 Ld 0 6.50' LOT 20 i7:E io S i r6k4L1 lob = (01900 Sq-(4 ' I Lxjs41'''x Mme& uoaS z: 2 uS 7%a 4 Deck. c I j 1-70 S14+ A3C w"o aiA MropA coa5 = '31(62S I NORTHWEST CORNER LOTyhh22KENSINGTONRESERVE PROPOSED = FINSHED SPOT GRADE ELEVATIONS PLOT PLAN ONLY NOT A SURVEY BUILD.ING' SET6ACKS: AS FURNISHEC PER DRAINAGE PLANS f= PROPOSED DRAINAGE FLOW PLOT PLAN AREA CALCULATIONS FRONT = 25 C'0 IMPERVIOUS COVERAGE = 2,455f SQUARE FEET OR 35,6Y SIDEREAR— 5'FOR 40''LOTSLOTGRADINGTYPEB PROPOSED FINISH FLOOR PER PLANS = 26,1' 5 Q05 Q(L LOT CONTAINS 6,900i SQUARE FEET LIVING AREA CONTAINS 1',714f SQUARE FEET SIDE = 7.5' FOR 60' LOTS SIDE = 10' FOR 75' LOTS CONC/LANAI/PORCH CONTAINS 741t SQUARE FEET SIDE STREET = 25' GRUSE N11Z_rZ'R—SCOTT & ASSOC,, INC, — LAND 1STURVE- RS LEGEND - LEGEND - P • PLAT PA,L, . POINT ON LINE 5400 E. COLONIAL DR. ORLANDO, FL, 32807 (407)-277-3232 FAX (407)-658-1436 F • FIELD TYP, • TYPICAL NOTES; I. P, • IRON PIPE P.R.C. . POINT OF REVERSE CURVATURE 1, THE UNDERSIGNED DOES HEREBY CERTIFY THAT THIS SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF IR •IRON ROD P,C,C, POINT OF COMPOUND CURVATURE C,H, a CONCRETE MONUMENT RAD, + RADIAL PROFESSIONAL SURVEYORS AND MAPPERS IN CHAPTER SJ-17 FLORIDA ADMINISTRATIVE CODE PURSUANT iQ SECTION 472.027, FLORIDA STATU SETI.R. . 1/2' I,R, w/NLB 4596 N.R, •NON-RA IAL 2, UNLESS EMBOSSED WITH SURVEYOR'S SIGNATURE AND ORIGINAL RAISED SEU., THIS SURVEY MAP OR COPIES ARE NOT VALID. RECpO' .RECOVERED W.P. CALCULATED PO[NT 3, THIS SURVEY WAS PREPARED FROM TITLE INFORMATION FURNISHED TO THE SURVEYOR. THERE MAY BE OTHER RESTRICTIONS P.O.B. • POINT OF BEGINNING CALL, •CALCULATED OR EASEMENTS THAT AFFECT THIS PROPERTY, P,O,C, .'POINT OF COMMENCEMENT P,R,H, „• PERMANENT REFERENCE MONUMENT 4. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOC47ED UNLESS OTHERWISE SHOWN. 4sNAILCENTLINEDISKF,F, BUILDINGSETBACK ELELINE VATION5, THIS SURVEY IS PREPARED FOR THE SOLE BENEFIT OF THOSE CERTIPIED TO AND SHOULD NOT BE RELIED UPON BY ANY OTHER ENTITY. t = NAIL 1. DISK B.S,L, • BUILDING FLOOR ELEVATION R1W = RIGHT-OF-WAY B.M. - BENCHMARK 6. DIMENSIONS SHOWN' FOR THE LOCATION OF IMPROVEMENTS HEREON SHOULD NOT RE USED TO RECONSTRUCT BOUNDARY LINES, ESHT, • EASEMENTB,B, = BASEBEARING 7. BEAR6NGS, ARE BASED ASSUMED DATUM AND ON THE LINE SHOWN AS BASE BEARING (B.B.) DRAIN. •DRAINAGEUTIL, UTILITY B, ELEVATIONS, IF SHOWN, ARE,, BASED ON NATIONAL CEDDE770 VERTICAL DATUM OF T929, UNLESS OTHERWISE NOTED. CL,FC, CHAIN LINK FENCE 9. CERTIFICATE OF AUTHOMIATI0N• No, 4596. WD.FC. • WOOD FENCE C/I CONCRETE BLOCKI P,C. POPONT OF CURVATURESCALE P,T, I 1" = ZO'-- 4 DRAWN BY. MLT NY OF TANGENCYDESC, • DESCRIPTION CERTIFIED BY,' DATER RADIUS ORDER, No. L • ARC LENGTH PLOT PLAN 12-14-17 5627-17 D • DELTA C = CHORD C' B' • CHORD BEARING , NORTH . THIS SUILDINC/ PROPERTY DOES NOT LIE WITHIN THE ESTABLISHED 100 YEAR FLOOD PLANE AS PER `FIRM" 70 RUSENM ER, 4714 ZONE 'X" MAP > 12117CO09OF (09-28-07) JAM E W. SCOTrR.L.S TV 4801 City Of Sanford Residential Pool / Spa / Hot Tub Safety Act Requirement Date 6/13/2018 Property Address 2334 Tudor Rose Dr, Sanford, FL 32773 Lot 19 Subdivision Kensington Reserve I hereby acknowledge that failure to equip a new residential swimming pool with at least one of the following pool safety features as required in Section 515.27, Florida Statutes, shall constitute a misdemeanor of the second degree, punishable as provided in s. 775.082 or s. 775.083. The pool must be isolated from access to the home by an enclosure that meets the pool barrier requirements of s. 515.29; ( Yao4 Fetc L,+knak wiU Vie.- +-ekC-Uob,.3) The pool must be equipped with an approved safety pool cover; All doors and windows providing direct access from the home to the pool must be equipped with an exit alarm that has a minimum sound pressure rating of 85 decibels at 10 feet; or All doors providing direct access from the home to the pool must be equipped with a self -closing, self - latching device with a release mechanism placed no lower than 54 inches above the floor. Company Name: Atlas Pools of Central FL Address: 3024 Kananwood Ct. STE 1016 License No: CPC 1457252 Signature of Contractor Bruce Wemple Printed Name of Contractor Oviedo, FL 32765 Phone No. 407-366-4600 I hereby acknowledge that the above referenced contractor has furnished me a document containing the requirements of Chapter 515, Florida Statutes, and a copy of the publication produced by the department under s. 5Ultovides information on drowning prevention and the responsibilities of pool ownership. Date: (o JAIZei i Signature 4f ner Printed Name of Owner June 2014 YardGard%20YG0'3[1].txt YARGARD YG03 GATE, DOOR, WINDOW ALARM YardGard(TM) Alarms are designed to alert you upon unsupervised entry to your yard or pool area. YardGard(Tm) meets- or exceeds state and local barrier alarm codes. Hardware is included for mounting on gates, doors, and windows. convenient single. button pass / reset opperation 7-second delay allowed •for adult pass -through 1.20 da, alarm siren - irinimum 95 dB at 10 feet Auto low battery ch-irpAllhardwareincluded for gate, door or wi ndaw mount Listed by C-17L 'to UL Standard, 2017 Water—resistant Alwayys on device as renu•i red by barrier codes, Can be, manually reset or Will clU tomat i cal l y reset in 3 i-wi nutes -to conti nuc, sirenAlarmgoesoffimmediatelywhentriggeredasrequiredbybarriercodes o'pera•tes on one 9-Volt battery (no-t 1 nc I . ) ai 17 ngual i nstal l at•i on/oper'ati on 'manual (Engl i sh/French) Page 1. Pentair TDH Calculator Page 1 of 2 0 PENTAIR TDH CALCULATOR Pool Information Flow Rate: 36 GPM Total Piping Lengths: Suction Lift: 0 Ft Inlet Side: 40 Ft Discharge Side: 40 Ft Maximum Pipe Velocity Allowed: Piping Sizes: consult your local code) Inlet Piping: 2.445 In Branch Piping: 6 Ft/Sec Discharge Piping: 2.445 In Inlet Piping: 8 Ft/Sec Discharge Piping: 10 FUSec Piping Head Loss at 36.00Gal/Min: not incuding fittings or valves) Inlet Piping: 0.37 Ft Discharge Piping: 0.37 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Suggested Minimum Pipe Sizes: Flow Rate: 36.00 Gal/Min Branch Piping: 1.5 In Your Head Loss: 15.72 Ft Inlet Piping: 1.5 In Maximum Flow Rate Discharge Piping: 1.5 In at Maximum RPM: 113.15 Gal/Min Ensure the drain cover max flow rating is not exceeded. Head Loss at 72.71 Ft Maximum Flow Rate: System Head Pressure Curve 30 25 20 015 10 5 0 l i i F. IntelliFlo Variable Speed, VS+SVRS, VF, or VSF - 1600 rpm clean SystemZd Desired Operation Point 0 10 Gu su 4V v Volumetric Flow Rate (GPM) https://www.pentairpartners.com/marketing/tdh/index.aspx 8/15/2018 Pentair TDH Calculator Page 2 of 2 Selected Components Components Head Loss at Name Quantity 36.00Gal/Min IntelliChlor IC - 40 1 0.81 2" x 2.5" 3 way valve 3 0.31 Main Drain 1 0.39 Clean and Clear RP 1 0.65 MasterTemp 1 10.90 3/4inch Return 3 1.20 Skimmer 2" 1 0.29 Piping Name 90 degree elbow Tee Through Tee Branch Pumps Name IntelliFlo Variable Speed, VS+SVRS, VF, or VSF Inlet Discharge Head Loss at Quantity Quantity 36.00Gal/Min 6 6 0.77 0 2 0.09 1 0 0.14 Quantity 1 All Pentair trademarks and logos are owned by Pentair, Inc. IntelliFloO, IntelliCommO, EasyTouchO, IntelliTouchO, SunTouchO, and Eco SelectTM are registered trademarks and/or trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Unless expressly noted, names and brands of third parties that may be used in1his document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving ourproducts and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. https://www.pentairpartners.com/marketing/tdh/index.aspx 8/15/2018 Swimming Pool Energy Efficiency. Compliance Information Note: These Requirements apply ONLY to the Filtration Pump ANSI 1 ASPC / ICC-15 2011 Flnrnr r'.alri dnfinn z- Pool water volume 12, Z45- 1360 = 3y • 01 gpm - this is the calculated flow rate Note: for pools under 13,000 gals. the calculated flow rate or 36 gpm whichever is greater = the filtration flow rate Note: Is there an Auxiliary load on the filtration pump? F] Yes X No If so, what is the calculated auxilliary flow rate - gpm Flow rate (low speed) 3(,o gpm @ _ rpm Minimum suction side pipe size @ 6 fps I in. Minimum suction side branch pipe size @ 6 fps I S in. Minimum return side pipe size @ 8 fps 1 ' in. Minimum return side branch pipe size @ 8 fps 1 in. Determine Fllter Size: Filter Factors (GPM/SF): I X I Cartridge (0.375) F D E (2.0) 1-1 Sand (15) Filter Size: A .//s ue375 = 9 0 ;D Flow Rate) (Filler Fact) (Filter Size) L3 1` ` Zoe Filter Make and Model ) Pump Controls: Filtration pump has no auxiliary load- standard time clock NA Filtration pump with auxiliary load -Control model for low speed default within 24 hrs Heater Model: P"i2 / LA - yppK Make,M/odel and Size) Gas Heater Efficiency Rating 't ®L (No Pilot Light) Heater Pump Efficiency C.O.P ANSI 5 & ANSI 7 Compliance Work Sheet Determine Simplified TDH: Distance from pool to pump in feet: 2' Friction loss (in suction pipe) in 3' Friction loss (in return pipe) in Determine Simplified TDH (CONTINUED): inch pipe per 1 ft. @ ------ inch pipe per 1 ft. @ 4.-------- x--------- = ------- Length of Suct. Pipe) (Ft of head/1 ft of Pipe) (TDH Suct. Pipe) 5.-------- x--------- _ ------ Length of Return Pipe) (Ft of head/1 ft ofPipe) (TDH Return Pipe) 154s +o>J0, gpm = ---- -- (from pipe flow/friction loss chart) gpm = ------- (from pipe flow/friction loss chart) TDH in Piping: Filter 1 Heater loss in TDH All other losses Total Dynamic Head (TDH): '7 Z,1 Determine Pipe,Sizes: Branch Piping to be 3 inch to keep velocity @ 6 fps max. at Trunk, Skimmer & Suction Piping to be 2 • S inch to keep velocity @ 8 fps max. at Return Piping to be 2• S inch to keep velocity @ Q fps max. at Pump Selection: as Listed on Curve(A } or C (circle one) 113.15 gpm System Flow Rate. 113.1 S- gpm System Flow Rate. 113.1 S gpm System Flow Rate. Filtration Pump (Prom/ T;4eu FCU VSF Maximum Flow Rate Main Drain Cover Determine the Number and Type of Required In -Floor Suction Outlets: Check all that apply. 0 3 -0' @2 4e"0,j,} suction outlets @ Q Q Q 3 suction outlets @ channel drain @ Total Head In Feet Conversion Chart Inches Mercury (Vacuum Gauge) 0 1 2 4 1 6 8 1 10 1 12 14 1 16d34.2 0 0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 1 2.3 4.6 6.8 9.1 11.4 13.6 15.9 18.1 20.4 2 4.6 6.9 9.1 11.4 13.7 15.9 18.2 20.4 22.7 3 6.9 9.2 11.5 13.7 16.0 18.2 20.5 22.8 25.0 4 9.2 11.5 13.8 16.0 18.3 20.5 22.8 25.1 27.3 5 11.5 13.8 16.1 18.3 20.6 22.8 25.1 27.4 29.6 6 13.9 16.1 18.4 20.6 22.9 25.2 27.4 29.7 31.9 7 16.2 18.4 20.7 23.0 25.2 27.5 29.7 32.0 34.3 36.5 8 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 38.8 9 20.8 23.1 25.3 27.6 29.8 32.1 34.3 36.6 38.9 41.1 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7, 38.9 41.2 43.4 11 25.4 27.7 29.9 32.2 34.5 36.7 39.0 41.2 43.5 45.8 12 27.7 30.0 32.2 34.5 36.8 39.0 41.3 43.5 45.8 48.1 13 30.0 32.3 34.6 36.8 39.1 41.3 43.6 45.9 48.1 50.4 t 14 32.3 34.6 36.9 39.1 41.4 43.6 45.9 48.2 50.4 52.7 r6 15U 34.6 36.9 39.2 41.4 43.7 45.9 48.2 50.5 52.7 55.0 2 16 37.0 39.2 41.5 43.7 46.0 48.3 50.5 52.8 55.0 57.3 17rn 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 n 18a 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 19 43.9 46.2 48.4 50.7 52.9 55.2 57.4 59.7 62.0 64.2 20 46.2 48.5 50.7 53.0 55.2 57.5 59.8 62.0 64.3 66.5 21 48.5 50.8 53.0 55.3 57.6 59.8 62.1 64.3 66.6 68.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 24 55.4 57.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 25 57.8 60.0 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78.1 26 60.1 1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 1 78.1 80.4 27 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 80.5 82.7 28 64.7 66.9 69.2 71.5 73.7 76.0 78.2 80.5 1 82.8 85.0 29 67.0 69.3 71.5 73.8 76.0 78.3 80.5 82.8 85.1 87.3 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92.0 32 73.9 76.2 78.4 80.7 83.0 85.2 87.5 89.7 92.0 94.3 33 76.2 78.5 80.7 83.0 85.3 87.5 89.8 92.0 94.3 96.6 34 78.5 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.6 98.9 35 80.9 1 83.1 85.4 87.6 89.9 92.2 94.4 96.7 1 98.9 101.2 NOTE: FIELD TDH MUST BE EQUAL TO OR HIGHER THAN THE CALCULATED TDH. 113.15 gpm Make and Model) 19-7 gpm max. flowZcoF!w/ gpm max, flow gpm w/ ports Flow and Friction Loss Per Foot Schedule 40 PVC Pipe Velocity - Feet Per Second Pipe Size 6 fps 8 fps 10 fps 1" 16 gpm 0.14' 21 gpm 0.23' 26 gpm 0.35' 37 gpm 0.08, 50 gpm 0. 14' 62 gpm 0.21' 2" 62 gpm 0.06, 82gpm 0.10, 103 gpm 0.16, 2.5" 88 gpm 0.05 117 gpm 0.09, 146 gpm 0.13' 3" 136 gpm 0.04' 181 gpm 0.07' 227 gpm 0.10, 4" 234 gpm 0.03' 313 gpm 0.05, 392 gpm 0.07' 6" 534 gpm 0.02' 712 gpm 0.03' TDH Calculation Options For each pump Check one. Simplified Total Dynamic Head (STDH) Complete STDH Worksheet - Fill in all blanks. Total Dynamic Head (TDH) Complete Program or other calcs. Fill in required blanks on worksheet & attach calculations. Maximum Flow Capacity of the new or replacement pump. IS Ig Mate V Contractors Signature CPC1457252 Contractors Cart. No. 407-366-4600 ContractorsTelephone No. owner sLe llSe(1 233H Tajo/ D-. A ` F( Scale: None 3trn-5 TRADEGRADE UNNU9 IntelliFlo VSF Pump INTELLIELO° VSF . HIGH PERFORMANCE PUMP select" Eight programmable speed or flaw settings and built-in tinter Rotatable keypad with optional wall mount kit (sold separately) Top -mounted field wiring compartment is easier to access and conneci Totallyenctosed fan -cooled design for increased performance and long life Applkrpe • Menus are easier than ever to use Effify enty . Precisely maintains system flow requirements Compatible with Pentair Automation This product may be protected by one or more of the following US Patents and all corresponding foreign counterparts: 7,686,587; 7,854,597; 8,043,070; 8,469,675; 81573,952; D5681340; D606,562; D611,430 IntelliFlo VSF pump is the first variable speed and flow pump that adjusts to changes in flow conditions to maintain its preprogrammed flow rate to run optimally throughout the entire filtration cycle. It's like having cruise control foryour pump. Ordering Information 10a 90- 80. 0 7D 6 u_ 60- a 50 40- 0 y 30- H - 20- 10- 0 INTELLIELO° VSF HIGH PERFORMANCE PUMP (CONT'D) Dimensions and Performance mmMMMEMM19.4-mmi r BBBBBBBBIB------------- 0 20 40 60 80 100 120 140 160 Volumetric Flow Rate in GPM Full Load Prinjy Listings and Port Size CartonProductModelVoltagekWHPSFSFHPFREQAmps , Certifications (NPT) Wt. [Lbs.) o • o 011056 IntelliFLOVSF 230 16 3.2 3 1.32 3.95 50Hz/60Hz UL', NSF2, APSP2 in. x 2 in. 55 SS•' Note: IntelliFlo VS+SVRS minimum speed is 1100 RPM r. , m- s,n^7• a--r, .•.'.ylg Y'- ,. --. - x..r .-,.> --. ..•. . _ + , t- },..:.. n.. s 1 1 r S21109 IntetliCom2''Reted9' 30V`DCwith4inpiil 350122 Communication Cable - 50 ft. - Included with pump 2 357156 Chemical Resistant Lid 1 T 356904Z Keypad Relocation Kit 2 [1 .in b 010. 8in 11201-0154 2 in. x 2 in. Union (2 in. NPT mate x 2 in. female NPT quick connect) ' Note: two required per pump (sold individuatly) 2 [275m1 m] 2 BinI " [ 71mm] indicates that pump bears a UL mark signifying evaluation to U.S. a 'APSP' Pump has been evaluated to ANSI/APSP/ICC-15 and California Standards UL1081 for Permanently Connected Swimming Pool and Spa Title 20 and is certified to use on Residential Swimming Pool Filtration Pumps and to Canadian Standards CAN/CSA C22.2 No. 108-01 Liquid Systems. Pumps For Swimming Pools Only (Enclosure 31. Product may have been evaluated to other state and local regulatory NSF' indicates that pump bears a mark signifying evaluation to NSF standards. Listing status may change. Always confirm status with Standard 50 For Self -Priming Centrifugal Pumps For Swimming Pools appropriate agency if in doubt. Only. Note: Pump must be used with current collectors when installed on spas or hot tubs in Canada. 1[4in 11 31[301 n Referto catalog page 50 fora selection of 2-Pole GFCI breakers which offer 6 milliamp personnel protection while meeting 2008 to current NEC Standards for Pool Pumps. 23.4in 7. 8in 199mm] G See page 501 for replacement parts. rR HIGH FLOW SAFETY DRAIN HIGH FLOW SAFETY DRAIN CERTIFICATE OF CONFORMITY SDX HIGH FLOW SAFETY DRAIN Submerged Suction Outlet For Single or Multiple Drain Use For Use on Wall and Floor No Sump Required The SDX High Flow Safety Drain is a 10" diameter frame and grate or bulkhead style drain fitting. It includes a back plate and cover that is affixed to a frame, a bulkhead or an existing drain sump. SDX Retro replaces most existing drain covers up to 1 0" in diameter. FLOW RATING FLOOR WALL One SDX or SDX Retro 200 GPM 192 GPM Square Inches of opening = 43.201 sq. inches Velocity @ 200 GPM = 1.485 fps PLACE OF MANUFACTURE: Paramount Pool & Spa Systems 295 E. Corporate Place Chandler, AZ 85225 USA 480) 893-7607 NAME OF THIRD PtARTY LABORATORY: IAPMO R&T LAB - TEST RECORD DOCUMENTATION: IAPMO R&T 5001 E. Philadelphia Street Ontario, CA 91 761 909) 472-41 04 Test Report —March 17, 2011 LIFE SPAN: 5 YEARS FROM DATE OF INSTALLATION COMPLIANT WITH: Virginia Graeme Baker Pool and Spa Safety Act ASME Al 1 2.19.8-2007 ANSI/APSP - 7 IAPMO Listed SDX Model Numbers: Concrete XXX-162-2212-XX Vinyl XXX-172-2212-XX Fiberglass XXX-182-2212-XX Retro XXX-192-2212-XX Retro Vinyl XXX-1 59-221 2-XX Retro Equalizer XXX-1 57-221 2-XX NSFlAN5180 Install Date ASME NA Replacement 5 years from installed date NOTE: Suction Safety Standards require that drain grates used to cover sumps must have the suction pipe cut at least 1.5 times the pipe diameter behind the drain cover. There is NO SUMP requirement for SDX because the patent- ed design provides uniform suction regardless of pipe location. If the pipe is too close to the back of the cover, it may restrict water flow to the pump, potentially reducing hydraulic efficiency, but this does not pose a suction safety hazard. This is confirmed by the IAPMO Test Report. This Product must be installed in accordance with all applicable Federal, State and Local Codes. R EV06301 1 JOIN I ti\ , 1 I11 ,I 1 IIr1/i/1/i%i!./i• . tee ••/'1 i\fin A 1111M.- NX MW 1 1111,1`I `1 t1.` 4A6W//jI6iII ,i 011j!1 1111 411, PENTAIR Select ry1 PENTAIR POOL/SPA CONTROL,SYSTFMS EasyTouch Features include: UltraTemp® Heat Pump integration Support for 2 VS or 2 VF Pumps Supports 8 Feature circuits MagicStream® Laminar support IntelliChem® Controller support Now works with ScreenLogic20 Interface IntetliBrite° Pool and Spa Light support SpaCommand® Spa -Side Remote support and control of IntelliFlo° Pump Optional Controllers for added convenience: Indoor Control Panel (for 4 EasyTouch System or 8 circuit systems), a Wireless controller [for 4 or 8 circuit systems), a QuickTouch° 114-function wireless remote, a 4-button spa side remote, and SpaCommand spa -side remote. iPhone°, iPad"-, Pod touch' Mobile Digital Device or Android° Device All functions controlled with easy, one -button access from the self-contained load center or optional controllers. No need to memorize operating sequences, open and close valves, or reset time clocks and thermostats. Built-in diagnostics include automatic verification of the display, microprocessor, switches, indicators, relay outputs, valve outputs, sensor inputs, and communication ports as well as a diagnostic screen that reports failures for troubleshooting and repair purposes Includes 150 amp breaker base with space for ten 1-inch breakers UL and cUL approved Dimensions: 26 in. H x 17 in. W x 5-1/4 in. D The EasyTouch Control System family offers control for homeowner's looking for an easy to use pool/spa control system. EasyTouch allows full control of all pool/spa features including advanced features such as colored lighting and IntelliChlor`2" Salt Chlorine Generator support. Every EasyTouch system includes an easy to use control panel that is built into the outdoor enclosure. This control panel allows for full system setup, programmability, and everyday operation. In addition, there are several other available remote interface choices. The EasyTouch systems come in a variety of configurations: Pool only or Spa only, Pool/Spa with shared equipment, and also integrated with Pentair Aquatic Systems' IntelliChlor salt chlorine generator. Ordering Information Product Model 520591 EasyTouch 4P - Single Body (base system - no ICP, no actuators) 520703 EasyTouch 8P - Single Body (base system - no ICP, no actuators) 520538 EasyTouch 4 - Pool/Spa (base system - no ICP, 2 actuators) 520540 EasyTouch 8 - Pool/Spa (base system - no ICP, 2 actuators) o- 520592 EasyTouch 4PSC-IC20-Single Body (includes SCG integration & IC20 cell) 520593 EasyTouch 4PSC-IC40 -Single Body [includes SCG integration & IC40 cell) 520704 EasyTouch 8PSC-IC20-Single Body (includes SCG integration & IC20 cell) 520705 EasyTouch 8PSC-IC40-Single Body (includes SCG integration & IC40 cell) 520542 EasyTouch 4SC-IC20 - Pool/Spa [includes SCG integration & IC20 cell, 2 actuators) 520543 EasyTouch 4SC-IC40- Pool/Spa (includes SCG integration & IC40 cell, 2 actuators) 520544 EasyTouch BSC-IC20 - Poot/Spa [includes SCG integration & IC20 cell, 2 actuators) 520545 EasyTouch BSC-IC40 - Pool/Spa (includes SCG integration & IC40 cell, 2 actuators) 521150 EasyTouch 8SC-IC60 - Pool/Spa (includes SCG integration & IC60 cell, 2 actuators) oCHPSi 520914 EasyTouch 4P-C - Single Body [salt ready system, cell must be ordered separately) 520915 EasyTouch 8-C - Pool/Spa [salt ready system, cell must be ordered separately) 520911 IntelliChlor IC20 Cell for Canada 520912 IntelliChlor IC40 cell for Canada See page 369 for replacement parts. PENTAIR ASTERTEP°, HEATER HIGH PERFORMANCE ECO-FRIFNDLY HEATERS 0 Cur Select Eft"., • cnnseiva . i 4 PENTAIR MasterTemp High Performance Heater Heats up fast so no long waits before enjoying your pool or spa Best -in -class energy efficiency* Manual gas shut-off when service is required Eco-friendly MasterTemp Heater is certified for Low NOx emission and outperforms industry standards Rotating digital display allows for easy viewing Tough, rustproof exterior handles the heat and weathers the elements Certified for outdoor and indoor installations For Air Intake Kit order part number 461031 MasterTemp heaters offer all the efficiency, convenience and reliability features you want in a pool heater, plus a lot more. As easy to use as your home heating system, plus, user-friendly indicator lights make system operation and monitoring a snap. The compact design and super -quiet operation won't intrude on your poolside leisure time. Heavy-duty (HD) unit with cupro- nickel exchanger stands up to the harshest of applications, like low pH, high flow or heavy use. Ordering Information Product Gas Type BTU 1000's) Carton Oty. Carton Wt. 460792 Natural 175 1 128 460793 Propane 175 1 128 460730 Natural 200 1 128 460731 Propane no 1 128 461000 Natural 200 ASME 1 138 461001 Propane 200 ASME 1 138 460732 Natural 250 1 133 460733 Propane 250 1 133 460771 Natural 250 ASME 1 140 460772 Propane 250 ASME 1 140 461020 Natural 250 ASME HD 1 140 460806 Natural 25OHD 1 136 460734 Natural 300 1 136 460735 Propane 300 1 136 460736 Natural 400 1 136 460737 Propane 400 1 136 460805 Natural 40OHD 1 136 460775 Natural 400ASME 1 149 461021 Natural 400 ASME HD 1 149 460776 Propane 400ASME 1 149 Note: The MasterTemp Heater is certified for tow NOx emissions. Standard Copper Heat Exchanger 84 % Efficient. Heavy Duty (HD) Cupro-Nicket Heat Exchanger 82% Efficient. GLOBRITE° WHITE AND COLOR LED LIGHTS UNDIRWATIR LID LIGHTS FOR SWIMMING POOLS AND SPAS 4 PENTAIR The brightest and most efficient LEDs available Can be placed in as little as 4 in. of water even in the floor pointing up Does not require grounding or bonding for quick and easy installations 5 brilliant fixed colors and 7 pre-programmed tight shows Compatible with IntelliTouch® or EasyTouch® Control Systems for advanced control features Compatible with gunite, fiberglass and vinyl pools 5 GloBrite LED Light ® Fiberglass Niche Select tR-kcy • G u! PENTAIR a' GloBrite LED Light $' Ua Vinyl Niche GloBrite LED Light Concrete Niche GloBrite LED Lights use advanced technology for energy -efficient, high quality light displays, delivered with enhanced LED brightness and superior optics, while using 18% less energy than other shallow water LED lights. Globrite lights are compatible with IntelliTouch and EasyTouch control systems and IntelliBrite 5g LED pool lights. GloBrite LED lighting is a brilliant way to showcase and enhance pool features like baja shelves, steps, beach entries and shallow water features. Note: Only GloBrite white lights have two dimming levels. GloBrite color lights cannot be dimmed. Ordering Information Cord Carton CartonProductVoltageWattageLength Qty. Wt: (Lbs.)' Ft.) 0'•CO 0• 1 602053 12 15W 30 1 5 602054 12 15W 50 1 6 602055 12 15W 100 1 9 602056 12 15W 150 1 12 Product Description Cord Carton CartonProductVoltageWattageLengthQty. Wt. (Lbs.) Ft.I 0: 1 602102 12 15W 30 1 5 602103 12 15W 50 1 6 602104 12 15W 100 1 9 602105 12 15W 150 1 12 Carton Qty. Carton Wt. (Lbs.) 620040 Gunite Niche for GloBrite (includes white, blue, black, grey and tan rings) 1 1.3 620039 Vinyl Niche for GloBrite (includes white, blue, and grey rings) 1 1.3 620041 Fiberglass Niche for GloBrite (white) 1 1.3 620093 Fiberglass Niche for GtoBrite (blue) 1 1.3 620094 Fiberglass Niche for GloBrite (grey) 1 1.3 9LMKITS 619993 1 GtoBrite Color 100 ft. with 300W Transformer+ Gunite Niche 1 25 619994 2 GtoBrite Color 100 ft. with 30OW Transformer+ 2 Gunite Niches 1 40 620051 1 GloBrite Color 100 ft. with 30OW Transformer +",Fiberglass Niche 1 25 620052 2 GloBrite Color 100 ft. with 30OW Transformer+ 2 Fiberglass Niches 1 40 620080 1 GloBrite Color 100 ft. with 30OW Transformer + Vinyl Niche 1 25 620081 2 GloBrite Color 100 ft. with 30OW Transformer+ 2 Vinyl Niches 1 40 GLOGRITE° WHITE AND COLOR LED LIGHTS (CONT'D) UNDERWATER FFD'LIGHTS FOR SWIMMING POOLS AND SPAS Ordering Information Product Description e: 602106 2 GloBrite White 100 ft. with 300W Transformer+ 2 Gunite Niches 602107 2 GtoBrite White 100 ft. with 300W Transformer+2 Fiberglass Niches 602108 2 GloBrite White 100 ft. with 300W Transformer+ 2 Vinyl Niches RM&R Q'SCAPEAND •ee 619962 12V-14V 100W 619963 12V-14V 30OW All Pentair UL Listed underwater lights are certified for use in fresh water with up to 6,000 ppm salinity. Dimensions and Certifications c uL us See page 480 for replacement parts. Carton Oty. Carton Wt. (Lbs.l PENTA114 INTELLICHLOV SALT CHLORINE GENERATOR Select RENTAIR IntelliChlor Salt Chlorine Generator Cell IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely, effectively, and automatically. Same sanitation performance as manual chlorine addition without the drawbacks. No need for customers to buy, transport and store chlorine compounds. Ordering Information Product Description 44 Minnie Full diagnostic capabilities, including cell life tracking that communicates remaining hours of cell life in real-time. Captures all performance data daily (production settings, hours of operation, chlorine output, cell cleaning cycles, salt readings, and water temperature averages). Push-button operation and easy -to -view displays enable fast checking of salt levels, cell cleanliness, sanitizer output, and water flow Automatic shut-off feature protects the unit and prolongs cell life under low water temperature conditions On -time cycling helps prevent calcium and scale build-up to maximize cell life Ability to commuhicate with IntelliTouch®, EasyTouchO, and SunTouch® Automation Systems 110 VAC or 220 VAC wiring (110 VAC only for IC151 Include 2 in. unions (IC15 unions adapt to 1 1/2 in.) Certified to UL 1081 standard for safety NSF approved Health Canada approved 520888 IntelliChlor IC15 Cell for Smaller Pools (US Version] - includes External Power Supply 521171 IntelliChtor Replacement External Power Supply for IC15 Carton Qty. Carton Wt. (Lbs.) 520554 IntelliChlor IC20 Celt (US Version) 1 7 520555 IntelliChlor IC40 Cell (US Version] 1 14 521105 IntelliChlor IC60 Cell (US Version] 1 16 520556 IntelliChlor Power Center [US Version] 1 13 522109 IntelliChlor IC15 (Canadian Version) 1 9 520911 IntelliChlor IC20 Cell (Canadian Versionl 1 7 520912 IntelliChtor IC40 Cell (Canadian Version) 1 14 520910 IntelliChlor Power Center (Canadian Version) 1 14 520588 IntelliChtor pass -through cell for winter or start-up 1 3 520594 IntelliChlor diagnostic wand 1 1 520595 IntelliChlor replacement unions (contains 2 0-rings, 2 couplers, 2 nuts) 1 1 520670 IntelliChlor Acid Washing Kit (includes closed -end union cap, O-ring, and coupling nut] 1 1 520734 15 foot extension power cord 1 1 520736 IntelliChlor Flow Switch replacement kit 1 1 521147 IntelliChlor Orings - Pack of Ten 1 1 521248Z IntelliChlor Power Center fuse holder replacement.w/fuse 10A 250V 1 1 521034Z IntelliChlor Power Center PC100 surge board replacement 1 1 521377 IntellipH canisterwith controller 1 18 IntelliChlor IC15 Replacement Reducer Unions - 2 in. to 1-1/2 in. (contains 2 0-rings, 2521495 1 1couplers, 2 nuts) 521633 IntelliChtor Debris Cross Guard - Pack of 5 1 1 10010 IntelliChlor Power Center fuse for IC15 OA 250V) 1 1 10006 InteltiChtor Power Center fuse for IC20, IC40, IC60 UOA 250V1 1 1 522745 IntelliChlor Power Center automotive style fuse replacement (10A/ 58V Mini -blade) 5 1 522431 IntelliChlor Surge Board PC100 Europe 1 1 CITY OF SANFORD BUILDING & FIRE PREVENTION UG018 PERMIT APPLICATION F Application No: Documented Construction Value: $ 600.00 Job Address: 2334 Tudor Rose Dr. Sanford, FL 32773 Historic District: Yes No Parcel ID: 17-20-31-5VC-0000-0190 Residential 0 Commercial Type of Work: New I Addition Alteration Repair Demo Change of Use Move Description of Work: Installing Pool Wiring for Swimming Pool Being Built By Atlas Pools of Central FL. Plan Review Contact Person: Shawn Fred Phone:407-366-4600 Fax:407-359-1916 Title: Permitting Supervisor Email: Shawn@AtlaspoolsofcentralFL.net Property Owner Information Name David & Keri Jensen Phone: 407-902-8507 Street: 2334 Tudor Rose Dr. City, State Zip: Sanford, FL 32773 Name Resident of property? : Contractor Information Emcee Electric (Michael Calhoun) Phone: 407-312-5410 Street: 460 N. Milwee St. City, State Zip: Longwood, FL 32750 Name: Street: City, St, Zip: Bonding Company: Address: Fax: Yes State License No.: EC0002325 Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 51h Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records ofthis county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance ofpermit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/Agent is Personally Known to Me or Produced ID Type of ID 4 8r, S l'e Signature of Contractor/Agent Date ZG r_l Print Contractor/Agent's Name Signature of Notary -State of Florida Date 00 ICEIVN ETH (ifl LAUVER III MY COMMISSION # FF235363 EXPIRES June 20, 2019 4C/139e-D'S3 FlowlallolpjScroco.:orr Contractor/Agent is Personally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas[] Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: June 30, 2015 Permit Application POWER OF ATTORNEY I hereby name and appointS&w6 T d 4-- Vte-/GJOAr45to be my lawful attorney in fact to act for me and apply to the Sa4--nr Building Department for a(n) Electrical permit for work to be performed at a location described as: Lot: 19 Subdivision: ter, Ten-y , Z33y -TZJx--, 1Pc— e Dr. &w,FC 32n3 Owner of Property and Address) to-31-Svc.- Olq O Parcel ID) And to sign my name and do all things necessary to this appointment. alhoun EC0002325 460 N. Milwee St., Longwood, FL 32750 407)312-5410 STATE OF FLORIDA; COUNTY OF SEMINOLE The foregoing instrument was acknowledged this 1!- day of , 201 0 by Michael Calhoun o is personally know to m or has produced type of identification) as identification. 11(/yG(/i r Signature of Notary Public, State of Florida K=HAR M1Ay 3536319 Kenneth M. Lauver III Print, Type, or Stamp Commissioned Name of Notary Public SCPA Parcel View: 17-20-31-5VC-0000-0190 Page 1 of 2 tenon CIA Property Record Card Parcel: 17-20-31-5VC-0000-0190 7 Property Address: 2334 TUDOR ROSE DR SANFORD, FL 32773 Parcel Information Value Summary Parcel 17-20-31-5VC-0000-0190 Owner(s) NVR INC Property Address 2334 TUDOR ROSE DR SANFORD, FL 32773 Mailing 1450 CENTREPARK BLVD #340 WEST PALM BEACH, FL 33401 Subdivision Name KENSINGTON RESERVE Tax District S1-SANFORD DOR Use Code 00-VACANT RESIDENTIAL Exemptions 60 60 60 60 21 j 20 0,9; 18 17 to r cn cn 60 60 60 60 60 2018 Working 2017 Certified Values Values Valuation Method Cost/Market Cost/Market Number of Buildings 0 0 Depreciated Bldg Value Depreciated EXFT Value Land Value (Market) 67,000 14,000 Land Value Ag Just/Market Value `" 67,000 14,000 Portability Adj Save Our Homes Ad' 0 0 Amendment 1 Adj 0 0 P&G Ad' 0 0 Assessed Value 67,000 14,000 Tax Amount without SOH: $266.00 2017 Tax Bill Amount $266.00 Tax Estimator Save Our Homes Savings: $0.00 Does NOT INCLUDE Non Ad Valorem Assessments j Legal Description LOT 19 KENSINGTON RESERVE PB 81 PGS 86-92 r---'-------------- -------- - = - - - - -. _-. e - - i Taxes i Taxing Authority I Assessment Value I Exempt Values I Taxable Value County General Fund i $67,000 i $0 $67,000 Schools $67,000 $0 I $67,000 1 -._ City Sanford $67,000 $0 $67,000 SJWM(Saint Johns Water Management) $67,000 $0 I $67,000 1 County Bonds $67,000 I $0 $67.000 j Sales Description Date Book Page Amount Qualified Vac/Imp SPECIAL WARRANTY DEED 1 4/1/2018 09120 E 0954 151,000 j Yes i Vacant L Find Comparable 5a1 I Land Method Frontage Depth Units Units Price Land Value LOT I i 1 $67.000.00 $67,000 Building Information - Permits___._..._._ Permit # Description Agency Amount CO Date Permit Date 02382 SCREEN ROOM I SANFORD 763 I 16/28/2018 00919 NEW HOME i SANFORD 357,748 I 13/29/2018 Permit data doesnotoriginate from the Seminole County PropertyAppralser's office. For details orquestions concerning a permit, please contact the building department ofthe taxdistrict In which thepropertyis located http://parceldetail. sepafl. org/PareelDetailInfo.aspx?PID=1720315VC0000019O 8/15/2018 POOL INSPECTION SEQUENCE BP# POOL PERMIT Min Max Inspection Description 10 20 Pool Plumbing Rough 20 Pool Foundation 30 Main Drain Piping 40 Pool Deck 50 Child Safety Act 60 1000 Plumbing Final 1000 Pool Final Address: ELECTRICAL PERMIT' Min Max Inspection Description 10 Light Niche Bonding 20 Pool Bonding Grid 1000 Electric Final REVISED: June 2014 Q .M3]I I hereby name and appoint '36,wn Pop k 4-1 keL ia4so be my lawful attorney in fact to act for me and apply to the Sae-4JL Building Department for a( n) wVInir Q Poopermit for work to be performed at a location described as: Lot: Subdivision: Owner of Property and Address) o, - 2a- 31- ! -v c -0000 -Ott o Parcel ID) And to sign my name and do all things necessary to this appointment. Bruce M. Wemple — CPC1457252 3024 Kananwood Ct Ste 1016 Oviedo, F1 32765 407-366- 4600 STATE OF FLORIDA; COUNTY OF SEMINOLE The foregoing instrument was acknowledged this day of - , 201 by Bruce M. Wemple o is personally known to or has produced type of identification) as identification. k Signature of Notary Public, State of Florida Kenneth M. Lauver III Print, Type, or Stamp Commissioned Name of Notary Public KENt EiH 14 LAUYER III Y' My CONIMISSION # FF235363 EXPIRES June 20. 2019 4L 0' S3 Flor cWNo7a1Sc:'K° cur SEAL This Instrument Prepared by Joseph C. Russo, Esq. Joseph C. Russo P.A. 3708 west Euclid Ave. Tampa, FL 33629 Return to: Victoria Root NVR Settlement Services, Inc. 1409 Tech Blvd., Suite 202, Tampa, FL 33619 as a necessary incident to the fulfillment of conditions contained in a title insurance commitment issued by it: Property Appraisers Parcel I.D. (Folio) Number(s): 17-20-31-5 VC-0000-0190 File No.: 532-52685-18 SPECIAL WARRANTY DEED Icf i" ea crigin! This Special Warranty Deed made the day of PUS} 20 19, by NVR, INC., a Virginia corporation, whose post office address is 4307 Vinela d Road, Suite H-16, , Orlando, FL 32811, hereinafter called the Grantor, to David L JENSEN and Keri L JENSEN, tenants by the entirety whose post office address is 2334 Tudor Rose Drive, Sanford, FL, 32773, hereinafter called the Grantee, WITNESSETH: That Grantor, for and in consideration of the sum of $ 10.00 Dollars, and other valuable considerations, receipt of which is hereby acknowledged, by these presents does grant, bargain, sell, alien, remise, release, convey and confirm unto Grantee, all that certain land situate in Seminole County, Florida, vim All that lot of land situate in Seminole County, Florida, more particularly described as Lot 19 as shown on plat entitled, "KENSINGTON RESERVE" and recorded with the Clerk of the Circuit Court, Public Records of Seminole County, Florida in Book 81, Pages 86-92. TOGETHER with all ofthe tenements, hereditaments and appurtenances thereto belonging or in anywise appertaining. TO HAVE AND TO HOLD the same in fee simple forever. AND Grantor hereby warrants the title to said land and will defend the same against the lawful claims of all persons claiming by, through or under the said Grantor, but against none other. Wherever used herein the terms "Grantor" and "Grantee" Includedall the parties to this instrument, and the heirs, legal representatives and assigns ofindividuals, and the successors and assigns ofcorporation.) 7 IN WITNESS WHEREOF, the Grantor has caused these presents to be executed in its name, and its corporate seal to be hereunto affixed, by its proper officers thereunto duly authorized the day and year first above N%Titten. I. NVR, Inc,, a Virginia corporation CH By: Name: ck Gargasz Title: ice President Signed, sealed and delivered in the presence of: Witness Signature: Witness Printed Name: Witness Signature' Witness Printed Name: STATE OF FLORIDA COUNTY OF ORANGE The foregoing Instrument was acknowledged before me thisy day of + 1 v 20_ tdo, by Nick Gargasz who is the Vice President of NVR, Inc., a Virginia corporation, on behalf of the corporation. He is personally known to me or has produced a driver's license(s) as identification. Printed Name: NOTARY PUBLIC Serial No.: My Commission expires: SLY Pub MEAGAN LYNNE FOWLER MY COMMISSION R GG 063253 EXPIRES: January 17.2021 E ofF-°p Bonded ThruBudget 40tary Serves fc rf 2 tE 4 ATLAS POOLS OF CENTRAL FLORIDA, INC. 3024 Kananwood Ct., Suite 1016 • Oviedo, FL 32765s- r PA (407) 366-4600 • (407) 273-4600 • Fax (407) 366-6023 AGREEMENT CPC1457252 1. PARTIES: Agreement between ATLAS POOLS OF CENTRAL FLORIDA, INC, hereinafter called the Contractor, David & Keri Jensen Hereinafter called the Owner 2. AGREEMENT: The Contractor agrees to build a residential swimming pool on the premisesdescribed as follows: Add 2334 Tudor Rose Dr. Sanford FL 32773 Lot 19 Kensington Reserve PB 81 PGS 86-92 3. PRICE and TERMS: 1) Total Contract Price Sixty Three Thousand Four Hundred Eighty Dollars 01100 63,480.00 ) payable as follows: 1) $ 6348.00 10% payable upon signing of this instrument as a deposit. 2) $ 19,044.00 30% upon completion of dig and steel. 19,044.003) $ 30 % upon completion of the concrete shell. 15,870.004) $ 25 % upon plumbing, extras, and after rough deck is poured. 5) $ N/A (if applicable) after fence or screen has been installed. 6) $ 3174.00 5% balance of contract price, prior to initial chlorination of the pool but, in any event, prior to the utilization of the pool by the Owner. Extras and/or Change Orders are in addition to the contract price and shall be paid when signed by the Owner. Progress payments are payments for completed work, and if not paid within 10 days from their due date they shall bear interest at the rate of 1 B% per annum until paid. 4. CONSTRUCTION SPECIFICATIONS: Contractor will install aswimming pool and appurtenant structuresand equipment in accordance with the plot plan and these construction specifications. Contractor reserves the right to substitute like or similar material, equipment orfixtures. The plot plan is intended to be a representation of the pool to be built and is not intended to represent an "as built" drawing, because pool location, elevation of pool, location of decking and enclosures are subject to changes due to set -back requirements, locations of existing improvements, soil conditions and other conditions beyond the control ofthe contractor. All measurements in the contract and on the plot plan are approximate and the pool dimensions contained in the contract may vary from the "as built" measurements. Deviations up to 3 inches are acceptable. Therefore, the parties agree that it is impossible to ascertain actual damages in the event of deviation from specified pool dimensions. The parties agree to adjust the contractprice of an amount calculated by multiplying the percentage reduction of surfacearea times one-half (1/2) of thetotal contract price fordiminished watersurface area, and $50.00 for eachvertical inch of depth deficiency measured onlyatthe main drain and shallowest portion of the pool as liquidated damages to owner resulting from said variations, if any. Depth is measured from the floor of the pool to the top of the water line tile. Any additional soil needed for decking or normal grading in excess of what is dug from the pool, is at the home owner's expense. Anyand all additions required by building department would be at owners expense. If a diving board or slide is installed, there is no liability assumed for injuries as a consequence of use or misuse of the diving board or slide. If a diving board or slide is installed later, there is no liability to the pool contractor and it shall cancel all warranties. EXISTING Sprinklers: Removal Homeowner Rerouting: Homeowner Planting: Removal Homeowner Resodding: Homeowner Fencing: POOL SHAPE Freeform Elevation Level Shallow Depth 3.5 Greatest Depth ' Greatest Width 16 Greatest Lenath 35 Interior Finish Stonescapes Pavers Homeowner Reinstalling: Homeowner 3 Color LED Globrite Pump Pentair VS 3hp Pump Filter Pentair 200cc Fliter Chlorinator Intellichlor IC40 Automation Easytouch 4 Screen Logic Heater Mastertemp 400k Auto Vac. System Valve Only Vac. Head, Hose, Brush Included Pole and Test Kit Included Tile 6x6 Termite Treatment Homeowner Screen N/A Additional Work: Eft Round spa with3ft Granite Spillway & Bubbler. Raised Decks on rear of pool with 48" sheer waterfall w/ Auto Valve. Underwater Light Handrail N/A Skimmer 1 Main Drain 2 Returns 3 Auto Timer N/A Shallow end Steps & Swimout Included Safety Barrier Homeowners 5. BUYERS RIGHT TO CANCEL: The Contractor shall not be obligated to commence construction of this pool until three (3) days after the signing of this contract by the Owner. Since this contract may be construed as a Home Solicitation Sale, purchaser is hereby notified of his right to cancel under the Home Solicitation Sales Act. This is a Home Solicitation Sale. If you do not want the goods or services contracted for, you may cancel this agreement by mailing a notice to seller. This notice must indicate that you do not want the goods and services and must be postmarked by midnight of the third day after you signed this agreement. If you cancel this agreement, the seller may keep all or part of the cash down payment. 6. OFFER AND AGREEMENT: This Contract Shall be deemed an offer to ATLAS POOLS OF CENTRAL FLORIDA, INC., and shall be null and void unless accepted by a duly authorized officer of the Contractor within ten (10) days of the date and year noted the Owners' signatures. The Salesman has no authority to bind the Contractor. All agreements and understandings are contained in this contract and the Owner warrants that there are no agreements or understandings other than are set forth in this document. Acceptance of the terms of this contract by Contractor is to be communicated to the Owner by transmitting a copy of this contract to them showing acceptance by the sellers by the execution of a duly authorized officerof the Contractor or by commencing construction. NOTICE TO PURCHASER DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ IT OR IF IT CONTAINS ANY BLANK SPACES You are entitled to an exact copy of this contract that you have signed and hereby acknowledge th it was completed and signed on the 1 Pth day of June / 2018 Presented by Brad Chambers OWNER Salesman OWNER Accepted by ATLAS POOLS OF CENTRAL FLORIDA, INC. STREETADDRESS 2334 Tudor Rose Dr. CITY. STATE & ZIP Sanford FL 32773 PHONE NUMBER 407-902-8507 NOTICE: SEE REVERSE SIDE FOR IMPORTANT WARRANTIES AND CONCLUSION OF CONTRACT. AP-SN01 12110 Reorder MBF407-557-7414 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 2601 BLAIR STONE ROAD TALLAHASSEE FL 32399-0783 850) 487-1395 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! F nda pyfAfTEOF FLRl-DEPARTMENT OV,':BUSIN.: SSANID PbR®SSIONAL R;EGULATION ? CPC145715, 2a _ ISSUEDi08/08/2018 RESIDENTIAAL POOL/ A CONTRAC&TOR WEMPLE BR,UCE,M-W;s '. . ATLAS POOLS OF CENTRAL FLORIDA INC 03 x5rx a Cdvri Y 1+WSignature..°cLICENSEDUNDERCHAPTERt4891FL40R'IDA STATUTES EXPIRATION DATE "AUGU 31r 2020 SEMINOLE COUNTY BUSINESS TAX RECEIPT JOEL M.. GREEN'BERG, SEMINOLE COUNTY TAX COLLECTOR PO BOX 1630 SANFORD, FL 32772 ) 407-665-1000 WWW.SEMINOLE000NTY_TAX VALID THROUGH 09/30/18 BRUCE M WEMPLE ATLAS POOLS OF CENTRAL FLORIDA INC 3024 KANANWOOD CT #1016 OVIEDO, FL 32765 BRUCE M WEMPLE .(OFFICER) Receipt #: OLHS2017082301105 Amount Paid; $ 45.00 Account #:155277 REGULATED License # - CPC1457252 Qualifier- BRUCE WEMPLE BUSINESS OWNER„ PLEASE NOTE THE FOLLOWING: Date Paid:08/23/2017 DISPLAY THE ABOVE -RECEIPT PROMINENTLY: This Business Tax Receipt shall be displayed conspicuously at the place of business in such a manner that it can be open to the view, of the public and subject to inspection by all duly authori2ed officers of the County. Upon failure to do so the: business shall be subject to the payment of .another business tax for the same business or profession. RENEW THIS TAX BEFORE IT EXPIRES: Pursuant to Florida Statutes, all Business Tax Receipts shall be issued by the Ta-x Collector beginning July 1 St of each year, and .it shall expire on September 30th of the succeeding year: Those Business Tax 'ReIce pts issued as renewal accounts beginning October 1st shall be delinquent and subject to a delinquency penalty of 10% for the month of October, plus an additional 5% pena:lty for each month of delinquency thereafter until paid; provided that the total penalty shall not exceed 256/6 of the business tax for the delinquent establishment (Florida Statute [FS) 205.053 [1l). A 25% penalty Shall be illiposed on any individual engaged in.any new business-Qr profession without first obtaining a Seminole County Business Tax receipt ((FS) 205..053 [2)j. This Business Tax. Receipt is' Only a receipt for business taxes paid. It does not permit the taxpayer to violate any existing regulatory or zoning laws of the state, county; or .municipality, nor does it exempt the taxpayer from any other required Licenses, registrations, certifications, or permits.. Business Tax requirements are subject to legislative change. REPORT ALL CHANGES The holder of this Busi.ness-Tax Receipt is required to report a change in the fallowing: Ownership, ,Business Location, .Mailing Address, or any other i:nformati.on that would alter the status of the current yea r's information: This includes, but is not limited to, the Joss of or a change in a State or Regutatory License which was used to qualify for the business identified on the current County Business Tax Receipt. If you have anythanges to report, contact the Business Tax. Department at 407-66S4636. BRUCE M 'WEMPLE ATLAS POOLS OF CENTRAL FLORIDA INC 3024 KANANWOOD CT #1016 OVIEDO, FL .32765 A o® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 7/30/2018 THIS CERTIFICATE'IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Insurance by Ken Brown, Inc. 707 Pennsylvania Ave Ste 1300 Altamonte Springs FL 32701 CONTACT NAME: PHONE FAx C, Ex : 321-397-3870 A/C No): 321-397-3888 E MA L ADDRESS: certificates@insbykenbrown.com INSURERS AFFORDING COVERAGE NAIC # INSURERA: Amerisure Ins Company 19488 INSURED ATLAS-2 Atlas Pools Of Central Florida Inc. INSURER B : Amerisure Mutual Ins. CO 23396 3028 Kananwood Ct, #1016 INSURER C : Oviedo FL 32765 INSURER D INSURER E INSURER F : COVERAGES CERTIFICATE NUMBER: 1039544603 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER EFFMM/DD/YYYY MMPOLICYLICYEXP DD/YYYY LIMITS A X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE X OCCUR CPP11565872601 4/1/2018 4/1/2019 EACH OCCURRENCE 1,000,000 DAMAGE TO RENTED PREMISES Ea occurrence 100,000 MED EXP (Any one person) 5,000 PERSONAL & ADV INJURY 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: POLICY X PRO - POLICY LOC OTHER: GENERAL AGGREGATE 2,000,000 PRODUCTS - COMP/OP AGG 2,000,000 A AUTOMOBILE LIABILITY X ANY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS X HIRED ( NON -OWNED AUTOS ONLY AUTOS ONLY CA11981212301 4/1/2018 4/1/2019 COMBINED SINGLE LIMIT Ea accident 1,000,000 BODILY INJURY (Per person) BODILY INJURY (Per accident) PROPERTYDAMAGE Per accident B X UMBRELLA LIAB EXCESS LIAB X OCCUR CLAIMS -MADE CU21003880302 4/1/2018 4/1/2019 EACH OCCURRENCE 1,000,000 AGGREGATE 1,000,000 DED I X I RETENTION $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANYPROPRIETOR/PARTNER/EXECUI I = OFFICER/MEMBER EXCLUDED? Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below N / A WC131539223 4/1/2018 4/1/2019 PER OTH- X I STATUTE ER E.L. EACH ACCIDENT 1,000,000 E.L. DISEASE - EA EMPLOYEE 1,000,000 E.L. DISEASE - POLICY LIMIT 1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. City of Sanford Building Dept. P.O. Box 1788 Sanford FL 32772 AUTHORIZED REPRESENTATIVE 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD i RICK SCOTT, GOVERNOR JONATHAN ZACHEM, SECRETARY i Florida STATE OF FLORIDA DEPARTMENT OF BUSINESS,,ANWPROFESSIONAL REGULATION ELECTRICALFCONTRQCtTORS LICENSJNG BOARD THE ELECTRICAL5 CONTRACTOR,HEREIN=IS CERTIIFF.IED UNDER THE A STATUTESPROVISI:N49-6FEf RTIER 4-89-FLORIDA C L,HO:UN M_ICH`AWL-MR EMCEE"'ELECTRIC*LLCM- ;. NMILNUEEST° LONGWOOD r FL^32-,750 f o LICENSE t MBER: b O',02325 EXPIRATIOFIrQATE Al1,GUST 31, 2020 Always verify licenses online at MyFloridal-icense.com ! I i Do not alter this document in any form. This is your license It is unlawful for anyone other than the licensee to use this document. BUSINESSTAX,_RECEIPT CITY OF LONGWOOD • Phone: (407)260-3440 w2018201;9175W. WARREN AVENUE http://www.longwoodfl LONGWOOD, FL32750 ryksr3 Recept # 19-00416 Issued Date:O7/17/18 Effectroe Date 10/01/18 Expiratlon,Date r0`9/30/.19 HOME OFFICE%ONE (1) EMPL'OYEELicensexTe Bins' ,5me EMCEE:ELECTRIC;'LLC a FLQR! qkevtasinessLo`caton: 460 N-1V1B1LWEE ST fir} OALHO,UN, MICHAEL S. c SEAL io y f 460 N MILWEE ST 10, NG.:WOOD FL 32750 ''-•. o` all FINANCE DIRECTOR: RECEIPT MUST BE CONSPICUOUSLY DISPLAYED AT BUSINESS LOCATION. EMCEE ELECTRIC, LLC CALHOUN, MICHAELS. 460 N MILWEE ST LONGWOOD, FL 32750 gYSTORIC E R " CERTIFICATE OF LIABILITY INSURANCE DATE(M/ 2018 Y) 08/15/018 THIS CERTIFICATEiS ISSUED AS A -MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Leslie BrianteNAME: Gentry Insurance Agency PHONE (407)886-3301 FAX (407)886-9530 AIC.No Ext : A/C No E-MAIL Leslie@gentryins.comADDRESS: 175 East Main Street INSURERS) AFFORDING COVERAGE NAIC # PO BOX 2046 INSURERA: Owners Insurance Company 32700APOPKAFL32704-2046 INSURED INSURER B : Auto -Owners Ins Co 18988 INSURER C : Markel Insurance 38970EmceeElectricLLC INSURER D : 460 N Milwee Street INSURER E : INSURER F: Longwood FL 32750 COVERAGES CERTIFICATE NUMBER: Master 2018 REVISION NUMBER: THIS IS TO CERTIFY THATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER POLICY EFF MM/DD/YYYY POLICY EXP MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE 1,000,000 CLAIMS -MADE OCCUR PREMISES Ea occurrence 50,000 MED EXP (Any one person) 5,000 PERSONAL & ADV INJURY 1,000,000A7268482707/15/2018 07/15/2019 GEN'LAGGREGATE LIMITAPPLIES PER: GENERAL AGGREGATE 2,000,000 X POLICY O-, JPRO LOC PRODUCTS - COMP/OP AGG 2,000,000 OTHER: AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident 300,000 BODILY INJURY (Per person) XANYAUTOB OWNED SCHEDULED AUTOS ONLY AUTOS 4239239500 07/15/2018 07/15/2019 BODILY INJURY (Per accident) PROPERTY DAMAGE Per accident HIRED NON -OWNED XAUTOSONLYXAUTOSONLYHired/ borrowed UMBRELLA LIAB OCCUR EACH OCCURRENCE HCLAIMS-MADE AGGREGATE JEXCESSLIABD RETENTION $ C WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y/ N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/ MEMBER EXCLUDED? El MandatoryinNH) NIA MWC0104119-02 12/14/2017 12/14/2018 H XSTATUTEERE. L. EACH ACCIDENT 100,000 E. L. DISEASE - EA EMPLOYEE 100,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT 500,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space Is required) tKI IFII;AI t MULUtK City of Sanford Building Dept P. O. Box 1788 Sanford SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE FL 32772-1788 Iq @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County, FLInst #2018100649 Book:9203 Page:784; (1 PAGES) RCD: 8/31/2018 2:20:54 PM THIS INSTRUMENT PREPARED BY: Name: Atlas Pools of Central FL, Inc. Address: 302$ Kananwood Ct. STE 1016 Oviedo, FL 32765 NOTICE OF COMMENCEMENT Permit Number: Parcel ID Number: 17-20-31-5VC-0000-0190 The undersigned hereby gives notice that improvement will be made to.certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available) Lot 19 Kensington Reserve PB 81 PGS 86-92 2334 Tudor Rose Dr. Sanford FL 32773 2. GENERAL DESCRIPTION OF IMPROVEMENT: Installing In -Ground Gunite Swimming Pool 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LESSEE CONTRACTED FOR THE IMPROVEMENT: Name and address: David & Ked Jensen 2334 Tudor Rose Dr. Sanford FL 32773 Interest in property: Owner Fee Simple Title Holder (if other than owner listed above) Name: 4. CONTRACTOR: Name: Atlas Pools of Central FL, Inc. Phone Number: (407) 366-4600 Address: 3024 Kananwood Ct. STE 1016 Oviedo, FL 32765 6. SURETY (If applicable, a copy of the payment bond is attached): Name: N/A Address: Amount of Bond: 6. LENDER: Name: N/A Phone Number: Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Name: N/A Phone Number: 8. In addition, Owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration is 1 year from date of recording unless a different date is specified) 1 Year WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Signs ure of er or Lessee• or owners or Lessee's (Pdnt Nameand Provide Signatorys Tille/Office) Au orized fficatlDirector/Partner/Manager) State of Florida County of Seminole The foregoing instrument was acknowledged before me this day of J lJr.4.r 20 lie by t 7enSef', Who is personally known tome OR Nameofperson makingstatement who has produced identification I] type of Identification produced: KENNETH M LAUVEH III MY COMMISSION # FF235363 EXPIRES June 20, 2019 tdi•/1'S9C-0'D'S Fmndado•1Senico.:o r Drivers License