HomeMy WebLinkAbout108 Westwood Ct - BR18-004340 - WINDOWS AND DOOR REPLACEMENTStreet: 820 E ALTAMONTE'DR Fax; 407-201-2278
City, State Zip;: ALTAmONTE SPRINGSFL 32701 Statelicense No.: CRC1.330822
Architect/Errgirieer Information
Name-, _NIA Phone:
Street:.,Fax:
City, Sty, Zip:,, E-mail
Bonding Company. N/A Mortgage Lender:
Address:- Address
WARNING TO OWNER: YOUR FAILURE TO RECORD A;:NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMLNTS TO VOUR PROPERTY. A NOTICE OF COMMENCEMENT 'MUST ?BE
RECORDED AND POSTED, ON THE JOB SITE BEFORE THE FIRSTINSPECTION. IF-, YOU INTEND TO. OBTAIN FINANCING,
CONSULT WITH. YOUR LENDER, OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:,
Application
is hereby made to obtain a permit to do the work and installations as indicated. I ccrtify that no work or installation',has commenced
prior to the issuance of a permit and that all work will ;;be 00formed to meet standards of.all laws regulating construction inthisjurisdiction. I understand that a separate permit must he secured far electrical work, plumbing,.. signs, wells, pools, furnaces, boilers, heatets,tanks, and air conditiouers„etc: FBG
105:3 Shall be inscribed with the date of application and the code in effect as of that date: 5t6 Edition (2014) Florida Building Code Revised:
June 30, 201S Permit, Application
management districts,,
restrictions applicable to this property that may. be
1ired.:ft.0rh_otfi6r rngoVemental entities suc'h..as. water
Acceotance of vermit is verification that I will notify the, owner of the property ofthe requirements of Florida Lien Law, FS -7,13
The City of Sanford requires payment o.f.'a plan review fee at theliffie"bf-pOftnit submittal. A copy of the executed contract is required: red
in order to calculate a plan review. charge:and will be considered the
1.
estimated construction value,of thejob, at the iime,of s'limittal, u
Thie Actual cohstruction.valuc.will'be figured based on the current,,ICIC Valuation Table in effea-at the time the permit is issued; in
Accordance with local, ordinance, ,Should calculated charges figured off the executed contract exceed the actual zebristiuctidn value, credit will be 'ied, issued. applied your permit fees when the permit is
OWNER'S'. AFFIDAVIT: I certify 'llhat,all'of the foregoing infoemationis accurate and that all work will
be done in compliance with all applicable. laws regulating construction and zoning.
E. lr6-r.,;tWt!n b6tepergen
ERIK JONES
Notary Public - State of FloridaazCommission0FF920J409
My Comm. Expires Sep 21, 2019C
Owner/Agent is, Personal y:.FnQwn tjWe,.or
Prod Type of ID L"e" Produced 11) yp
S71atu ofContraciortAgetit DX-7
I - , Ud
Print Conkactor/Agcnt's Nome
s afts ofNato ry-Sttiw of Floria DateipIu
OS Millie Hawkins
qIII
V-
1
ok NOTARY PUBLICSTATEOFFLORIDA
Comm# GG245440PV00CEis' Expires 8/5/2022
Contractor/Agent is" Personally Known4o.Me or
Produced ID,- "Type of ID,
Permits Required: Building Electrical-M Me chanicai 0 Plurh6ihg[I GasE] Roof
Construction Type:, Occupancy Use: -Zone: Flood'
Total. Sq Ft of Bldg,:_ 'Min.,Occupancy Load: ofStori&. New
Construction: Electric - # of Amps Plumbing - # of Futures vsFire
Sprifikleir Permit- Yes [] NoEl kof Heads Fite Alarm Perm - it: YesNo APPROVALS: ZONING:,
UTILITIES,-- WASTE WATER:. ENGINEERINGBUILDING:; : FIRE,
BUILDIN COMMENTS:, Revised: -June
30.
20 . 15 Pennit,APPfication
REQUIMEIID INSP ECTI
I JIlIllI t' 1 AA Il®IlIl ](D Il'Il It®IlIl.
Footer / Setback
Remwall !
Foundatioii / Form Board.'Survey
Slab-/*M-ozio STab Pre our
Lintel / Tie- Beam / Fill / Down Cell
j Sheathing— 1- aHs'
Sheathing'' Roof
Roof Dry 111
Frame
IInsulation Rough Tn
Firewall Screw Pattern
Drywall / Sheetrock
jLath Ins : ection
Final Solar (
Final Roof .I:
Final Stucco / ,Siding
Insulation Final
Final Utility; Building'
Final Door
Final Window
Final Screen.Room
FinalPool Screen Enclosure'
Mobile Home Building Final
Pre: Demo
Final Demo I
Final' Single OamuTy,. Residence Final.
Building Other i (
N-
SIEQUIENCIE: Addiress:
I
i
1
J[nm max Isms 6,cdonDescri lido Electric.
Underground F'
ooter /' Slab Steel Bond Electrzc
Rough T.
U.G. Pre -
Power Final Electric
Final min
Max 41
x "•dl 2:+_')1r. 'r,'.
hnspe
flom AD1{e sEEA:2floim Plumbing
Underground Plumbing
Sewer • . Plumbing
Tub Set 1
Plumb'ingFinalI
i
p51{,,{.•'+
aC,':a::I/,1y`gAlx:.ji(j. iL'1.•4'MW*.xICI li1`714Orate..: L j.L;y:•.j,l.../'ry j iMnn
Max I<Ms ec6m Desemfl tnom Mechanical
Rough Mech.
ancal. Final 1
II IlIl1M('}Y I I IlIls 1®m. ]ID s 1Cll $'Il m I
Gas Underground - Gas
Rough Gas.
Final R
EWS ED, June 2014
Grant Maloy, Clerk Of The Circuit Court & Comptroller Seminole County FL
Inst #2018121389 Book:9236 Page:946; (1 PAGES) RCD: 10/22/2018 10:50:52 AM
REC FEE $10.00
riY r(:1:s]lt a'II -
NOTICE OF COMMENCEMENT
State of Florida
County of Seminole
Permit Number: Parcel 0 Number. 12-20-30-501-0000-0590
The underelpned hereby elves notice that Improvement will be made to certain real property. and in accordance with
Chapter 713. Florida Staknes, the following Infomwflon Is provided in this Notice of Commencement.
DESCRIPTION OF PROPERTY: (Legal description of the property and street address if available)
LOT 59 198 WESTWOOD CT MNFORD, FL 32773
SOUTH PINECREST 2ND ADD
PB 10 PG 89
OF IMPROVEMENT:
WINDOWS AND/OR DOORS SIZE FOR SIZE
OWNER INFORMATION:
Name: BALL, ELIZABETH K & JOHN C
Address: 108 WESTWOOD CT SANFORD, FL 32773
Fee Simple Title NoMer (N other then ewer) flame:
Address:
CONTRACTOR:
Name: Samuel Odvstein/New South Winnow
Address: 820 E Altamonte Drive, Altamonte Springs, FL 32701
Persons within the She d Ftorids Designated by Owner upon whom notice or other docurnenis may be served
as provided by Section 713.13(1)(b), Florida Stabdes.
No":
Address:
in addition to himsW, Owner Designates
To receive a copy ofthe Uenor's Notice as Provided in
Section 713.13(1Xb), Florida StahAes.
Expiration Daft of Notice of Commencement (The otplration dote is 1 year from date of recording unless a
d9ter0et date is specftd)
WARMIMQ TO OWNED ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF
COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART t, SECTION 713.13,
FLORIDA STATUTES. AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A
NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
IMPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalties of perjury. I declare that I have read the foregoing and that the facts stated In It an tare
to t1w4mat of my knowledge and belief.
11C-l?
Owwa ow wrs PrYded Now
R&IOs Rw to 713.1301tg> "The amw must sign fie nodts dcommrxwmitl end no one dse may be pa mlded to sego In his orher swad.'
Stated Fk> w _County of 45e",wteje
The foregolnil Insaument//was acknow N dged before me this _ day of k cicr S
by El-'bC 1,,// C . Who Is personallyknown to me
Name d person msMing etatemena
OR who has produced Ideniffication type of ItleiLtication produced: _ I+ L +.' w f r e Se
ERIK JONES
Notary Public - Suit of Florida
Cotnnllsslon a FF 920409
1„
My Comm. Expires Sep 21, 2010
eA _
D City oSanford
Building and Fire Prevention
Product Approval Specification Form
Permit #
Project Location Address PL
As required by Florida Statute 553.842 and Florida Administrative Code 9N-3, please provide the
information and product approval number(s) on the building components listed below if they are to be
utilized on the construction project for which you are applying for a building permit. We recommend that
you contact your local product supplier should you not know the product approval number for any of the
applicable listed products. Be aware that windows, skylights, and exterior doors must be tested in
accordance with the Florida Building Code, Section 1714.5. More information about Statewide Product
Approval can be obtained at www.floridabuilding.org.
The following information must be available on the jobsite for inspections:
1. This entire product approval form
2. A copy of the manufacturer's installation details and requirements for each product.
Category / Subcategory Manufacturer Product
Description
Florida Approval #
include decimal
1. Exterior Doors
Swinging
Sliding
Sectional
Roll Up
Automatic
Other
2. Windows
Single Hun
Horizontal Slider
Casement
Double Hun
Fixed
Awning
Pass Through
Projected
Mullions
Wind Breaker
Dual Action
Other
June 2014
Category / Subcategory Manufacturer Product
Description
Florida Approval #
including decimal
3. Panel Walls
Siding
Soffits
Storefronts
Curtain Walls
Wall Louver
Glass block
Membrane
Greenhouse
E.P.S Composite
Panels
Other
4. Roofing Products
Asphalt Shingles
Underla ments
Roofing Fasteners
Nonstructural
Metal Roofing
Wood Shakes and
Shingles
Roofing tiles
Roofing
Insulation
Waterproofing
Built up roofing
System
Modified Bitumen
Single Ply Roof
Systems
Roofing slate
Cements/
Adhesives /
Coating
Liquid Applied
Roofing Systems
Roof Tile
adhesive
Spray Applied
Polyurethane
Roofing
E.P.S. Roof
Panels
Roof Vents
Other
June 2014
Category/ Subcategory Manufacturer Product
Description
Florida Approval #
include decimal
5. Shutters
Accordion
Bahama
Colonial
Roll up
Equipment
Other
6. Skylights
Skylights
Other
7. Structural
Components
Wood Connectors /
Anchors
Truss Plates
Engineered Lumber
Railing
Coolers/Freezers
Concrete Admixtures
Precast Lintels
Insulation Forms
Plastics
Deck / Roof
Wall
Prefab Sheds
Other
8. New Exterior
Envelope Products
Applicant's Signature
Applicant's Name LIL'Oe
Please Print)
June 2014 3
eau ut 820 East Altamonte Dr. aAltamdiRe Springs, FL 32701
407-261-2277 "407-261-2278 fax
WINDOW so1.UT1ONS www.NewwpSouthWindow.com
Made in the South forthe South. Date C_ /_;/ P
To _4::_1;-7 a_
1-,
4 .4 kl 9,o— E-mail c T rt a rr,
1 U! /"k C!+ Home Phone CellPhone
c— —77? V 7y
City cJ State F - Zipe V Business (1 . / Mrs.) 2)-J - b J (e"d Lr'- :/ Replacement
Windows • Entry &Patio Doors . Storm Doors • Impact Resistant Windows & Doors WHOLESALE &
RETAIL WINDOW CONTRACT NewSouth
Window Solutionsaarees to measure, manufacture or furnish and service thefollowina custom made windows for the amount STIPULATED BELOW: All
NewSouth Vantage Series Windows include Double Pane, LoE glass with Argon gas, and 12 point fusion welded corners. R
eVantage windows are Sashlite'"'sealed andvacuum testedwith a foam, enhanced sash and frame. S?
99it ligfu!exterior onll G `' inL:dor Cob ,._ 7an Cotots mayvary sligtay horn sample 6niWq GW9ilionitwnolewinooh11eOTsn (h _ Y write
in mbN OUANTITY
OBSCURE GLASS YES LOCATION:
ouAHn7r
PVC COILTRLAA COLOR:
TEMPEREDGLASS
O YES LOCATION:
NO wTLR1UTownscwpsAsYLLvnnwurcA0O5Lenroz
mLL Li
Vantage 7antage cl Mantage DOUBLE
HUNG VANTAGE SERIES HALF -
SCREEN) CASEMENT FULL
XREENI onFullScreen2
LITESLIDER VANTAGE SERIES IHALF-
SCREEN) DOUBLE CASEMENT TWO
FULL SCREENSI i
Full screen PICTURE
INn
SCREEN) F1WINDOWVANTAGE SERIES DOUBLECASEMENT WITH
FIXED CENTER 3
LITE SLIDER PICTURE
WINDOW AWNING & HOPPERTILT WINDOW IFULLSCnEENI
VANTAGESERIES1
WOSCREENSI Cobr option al White or Tan only. PICTURE
WINDOW WITH DOUBLE
RUNGS PATIO
DOORS O 5/0 a 6/e (591/7 a 791/2") 0
WE) x SM (/1 1 /2- X 791 /2") Indicate
the WO X 8/0 (71 1/2- x 951/2-) VANTAGESERIESdirectionofslide08MX6/6 (95 V2- X 791/2-) IWOHALFSCREENS). I OXO DI OX 09/0 X(1/6 11071/2-X 791/2-) G
HALF EYEBROW ,/mil GTRAP RAW
SHAPEDWINDOWS (NOT FOAM ENHANCED) ROUND r IOTHERIN SPACE Ilj..._..i'
J
GRID
STYLES Q STANDARD CONTOUR BRASS/GOLD/PENCIL Was thishome built prior to1978? Yes ElNo crlonlal
Prafne. i O open Prahte If yes, the undersigned agress to the terms and conditions
of the NewSouth Lead Safe Work Practices
Addendum. e
naiuR TOTAL
NUMBER OF WINDOWS ON THIS ORDER: OTHER:
Customer
agrees tc allow New outh to display a yard sign until 30 days after completion. TWO YEARS FREE IN HOME SERVICE BUYER'
S RIGHT TO CANCEL Total price' S rn BUYER
MAY CANCEL THIS CONTRACT BY DELIVERING WRITTEN NOTICE TO
THE SELLER AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD Down payment S BUSINESSDAYAFTERTHEDATEOFTHISTRANSACTION. BUYER MAY USE
THIS CONTRACT AS THAT NOTICE.BY WRITING "I HEREBY CANCEL" AT.
THE BOTTOM AND ADDING BUYER'S NAME AND ADDRESS..THE. Balance payable on NOTICE
MUST BE DELIVERED TO THE SELLER ATTHE ADDRESS SHOWN Installation/Delivery S V 22 7 ABOVE.
O Bank Financing +Gash on Completion All
material is guaranteed to be as specified. All work is to be completed in a workmanlike manner according to standards and practices. This contract
is valid only with proper signatures. NewSouth shall not be held responsible for time and material delays, strikes, acts of God or any other
matters beyond its control. Owner agrees that the equity in this property is security for this contract. Since this contract calls for made to order
goods, it is not subject to cancellation except as stated above. Start installation approximately weeks from above date. Verbal promises
can cause misunderstandings, therefore this contract constitutes the entire understanding of the parties, and no other understanding, collateral,
verbal or otherwise; shall be binding, unless signed by both parties. NewSouth to remove and haul away all job related debris. All sales
and discounts allotted. All charges included above.Thank you for your order. x
x Buy
ig ture epresentative x
x Buyer
ignature NewSouth Manufacturing Authorized Officer
820 E. Altamonte Springs Dr.
Altamonte Springs, FL, 32701ivewaouinPhone: (407) 261-2277
WINDOW OWTION Fax: (407) 261-2278
Contact Email : milliehawkins@newsouthwindow.com
To Whom It May Concern:
I, Samuel Ochstein, hereby authorize the following named person (s) to sign my name on my behalf to
apply for and purchase permits for New South Window Solutions of Orlando.
This list is to replace all others previously issued, which are now to be considered null and void.
TYLER LEE
FRED BROWN
DAN FINK
JUSTIN SHAW
ELAINE LEWIS
Job Address: 108 WESTWOOD CT SANFORD, FL 32771
Sincerely,
Samuel Ochstein
CRC1330822
State of Florida, County of _SEMINOLE
Iq
This foregoing instrument was acknowledged before me this J__L day of C - 2018, by
Samuel Eli Ochstein, who is personally known to me and did not take an oath.
otpRyAss Millie Hawkins
aQ ° NOTARY PUBLIC
STATE OF FLORIDA
Comm# GG245440
ONCE 19 Expires 8/5/2022
MILLIE HAWKINS BiVAD_
Print name Notary Signature and seal
Notes, RECORD COPY
Window Spwiflcoonl and D+eUllf
Purm-d to Convict wit, NewS A WMdDw SWuttons
Cvstatier:
H SrQ Y7 Sri y. ICj 1— t+1
a-
First Floorrp
pit CIA,
vJ6i3If i> of
wumracr tmae: rr - . _[ U eaynory Heg: /_ [ . tii P+-
Custo 2r Approval:
rarnes Screens Insu ' Gloms tkui tons
TYPE aYrtnrLocationcelw
t EXTANT
M xHt
Sates Memre
iwxa4x_H__
013 iin S" Make Size
Z rx u x i xW
S4. ko x (0 : x
I x Jt
REVIEWED FOR CODE COMPLIANCE
151=
PLANS EXAMINER
DATE
iFQRD BUf DING DIVISION
A PERMIT ISSUED SHALL BE CONSTRUED TO BE A
LICENSE TO PROCEED WITH THE WORK AND NOT AS
AUTHORITY TO VIOLATE, CANCEL, ALTER OR SET
ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL
CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT
THE BUILDING OFFICIAL FROM THEREAFTER
REQUIRING A CORRECTION OF ERRORS IN PLANS,
CONSTRUCTION OR VIOLATIONS OF THIS CODE
S
o 04
1t1EN1.
4,34 0
8/28/2018 , Florida Building Code Online
1ffiPONsnss ianal Regulatan
BCIS Home I Log In I User Registration
FI lida
11j, Product Approval
USER: Public Userr
I.W, o-'eap
Hot Topics I Submit Surcharge I Stats & Facts I Publications
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL16842-R4
Revision
2017
Approved
9
NewSouth Window Solutions
4901 oak fair bivd
tampa, FL 33610
513)284-0129
danochstein@newsouthwindow.com
Vivian Wright
rickw@rwbldgconsultants.com
Windows
Horizontal Slider
Contact Us I B
Evaluation Report from a Florida Registered Archii
Professional Engineer
u Evaluation Report - Hardcopy Received
Lyndon F. Schmidt, P.E.
PE-43409
National Accreditation and Management Institute
12/31/2018
Ryan 1. King, P.E.
Validation Checklist - Hardcopy Received
FL16842 R4 COI (c) Certificate of Independenc
Standard
AAMA/ W DMA/CSA 101/I. S. 2/A440
AAMA/W DMA/CSA101/I.S.2/A440
AAMA/W DMA/CSA101/I.S.2/A440
ASTM E1886
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA°/`3d%3d 1/6
8/28/2018 Florida Building Code Online
ASTM E1996
ASTM E1996
ASTM E1996
TAS 201, 202, 203
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page [ a
Method 1 Option D
04/ 11/2017
10/20/2017
10/23/2017
12/12/2017
FL # Model, Number or Name Description
16842.1 a. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizont,
Nail Fin Installation (XO or OX configu
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.1.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.1 for Design Pressure Ratings, any FL16842_R4_AE (b) Eval 16842.1.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.2 b. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizont;
Flange Installation (XO or OX configur.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.2.)f
Verified By: Lyndon F. Schmidt, P.E. 4ApprovedforuseoutsideHVHZ: Yes
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.2.pdd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.3 c. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli
Impact Rated Fin Installation (XO or OX configuratio
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.3.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.3.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.4 d. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli,
Impact Rated Installation (XO or OX configurations)
Limits of Use Installation Instructions
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 2/6
8/28/2018 Florida Building Code Online
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.4.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.4.pd
Created by Independent Third Party: additional use limitations, installation instructions and product
particulars.
16842.5 e. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli
Impact Rated - HVHZ Fin Installation (XO or OX configuratio
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.5.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.5.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.6 f. Series 9000 Model 9550 Slider XO - Extruded Vinyl "Impact" Horizontal Sli,
Impact Rated - HVHZ Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.6.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.6.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.7 g. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizont,
XOX Nail Fin Installation (XOX, configuratio
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.7.if
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.7.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.8 h. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizont;
XOX Flange Installation (XOX, configuratior
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.8.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.8.pdd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.9 i. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sli,
XOX - Impact Rated Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.9.pd
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.10 j. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Slip
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 3/6
8/28/2018 Florida Building Code Online
XOX - Impact Rated Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.10.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.10.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.11 k. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact" Horizontal Sli
XOX - Impact Rated - HVHZ Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.11.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.11.p
additional use limitations, installation instructions and product
particulars.
Created by Independent Third Party:
16842.12 I. Series 9000 Model 9500-3 Slider Extruded Vinyl "Impact" Horizontal Sli,
XOX - Impact Rated - HVHZ Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.12.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: Yes Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.12.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizont;
Nail Fin Installation (XX, configuration
Limits of Use installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.13.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.13.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.14 In. DuraGard Slider XX Extruded Vinyl "Non -Impact" Horizont:
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.14.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.14.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.15 o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont;
Nail Fin Installation (XOX, configuratio
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (j2) Inst 16842.15.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.15.p
Created by Independent Third Party:
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 4/6
Florida Building Code Online
additional use limitations, installation instructions and product
particulars.
16842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont,
Flange Installation (XOX, configuratior
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.16.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.16.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.17 q. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizont;
Nail Fin Installation (XX, configuration
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.17.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R4 AE (12) Eval 16842.17.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.18 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizont;
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (2) Inst 16842.18.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.18.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.19 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont;
Nail Fin Installation (XOX, configuratio
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.19.pd
Verified By: Lyndon F. Schmidt, P.E. 4ApprovedforuseoutsideHVHZ: Yes
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.19.p
additional use limitations, installation instructions and product Created by Independent Third Party:
particulars.
16842.20 t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact" Horizont,
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.20.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 4
Impact Resistant: No Created by Independent Third Party:
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R4 AE (2) Eval 16842.20.p
Created by Independent Third Party: additional use limitations, installation instructions and product
particulars.
Go to Pagerr j
Back Next
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 5/6
8/28/2018 Florida Building Code Online
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Qgpyjjght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility !S
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a pub
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please cor
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the I
if they have one. The emails provided may be used for official communication with the licensee. However email addresses are
to supply a personal address, please provide the Department with an email address which can be made available to the pL
licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
F90-1 9 M
P
i6c, :itJ A+61 [ 's
r fi. P =_
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 6/6
EPWINDOWSOLUTIONS
M III
ewSouth
V\
4901 OakFairBlvd., Tampa, FL 33610
DuraGard Slider XX
WO N-'IYIml. rr
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 6th Edtion (2017) Roddo
Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone'
HVHZ).
2. Productanchors shall beas fisted and spaced asshown on details. Anchorembedment
to base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product is required to be
protected with an impact resistant covering that complies with FBC Sections 1609.1.2 &
R301.2.1.2.
4. For 2x stud framing construction, anchoring of these units shall be the some as that
shown for 2x buck masonry construction.
5. Site conditions thatdeviate from the details ofthis drawing require furtherengineering
analysis by a licensed engineeror registered architect.
TABLE OF CONTENTS
SHEET# DESCRIPTION
1 Typical elevations, design pressures & general notes
2 Vertical & horizontal cross sections
3 Vertical & horizontal cross sections
4 Buck & frame anchoring
5 Bill of materials, glazing details and components
FRAME WIDTH
1
DESIGNRRESSURE
FRAME
DIMENSION
DAY'UGHi
DIMENSION
G(ASS
TYPE
72.0" x 65.0" 32.56" x 511.S" Gt 30.0 30.0
72.0" x 56.0" 32.56" x 49.5" Gl 35.0 35.0
Imo'/'•• y J'mWM)
000
N Ew Z.p Z8mu
O o 3a L m
a 4
m Gi a W
z0
Q c WS d
SCALE: N.T'.S.
MG. BY: JK
CHK. BY: LFS
DRAWNG NO.:
FL-16842.14
SHEET 1 OF S
D Z i
NOTE: Sheet MetalScrews must penetrate a D
ts
1` A
L min. of 3 threads through at least 2 sheets ofX mg 4_0 1
metal (maintain a min. 3/6' edge distance). J' ci ro
C
INTERIOR n
cz 4m
roEc
a °' zoUN
B
t S i c=o
X X 8 ua 9m`ao
1
o C
v o a Na maa12
2 E a
K
M
1
LL EXTERIOR o No
Z 3 OU
2 3 HORIZONTAL CROSS SECTION 2
2 Steel Stud Construction Z m .y
G1 N u U
q 1-IIN' MIN. EXTERIOR INTERIOR I o
6 IJv1B. RrPJ o
a a
V
s" g C
1 3 2 UU
J mT
a 6
T1 O.:.O Q- EJ
nv
NN
14
g
WW
rn
oZ
is ill
N
y o CaQINTERIOR w F
G1
AzzzEXTERIOR
w Gl o°
DATE: 3120112a3DEc oSCAE: N.T.S. 3
E Z a owc. er: JK m
0H1• e1 1 HORIZONTAL CROSS SECTION D 2 VERTICAL CROSS SECTION m OiUWINC NO.:
FL-16842.14 a
2 2X Buck Masonry ConstructionZ Z 2X Buck Masonry Construction w
i
h
SHEET _L OF $
A
D /
X X
d'
oE . .. da a
i '•. % f. e1 ro
G A Z rar p * 11'. Z o 'm o
8 C U N ZJ
711 Z l
C Rj 8 E.9 mcWupoo. o m maa2Km
a
v ,
ui
0 El j o d
3
2 ItzV)
NO
G1 ^ o
F J ,)
2 3 EXTERIOR INTERIOR o w vN
3 3 t I VERTICAL CROSS SECTION o `er'
3 a
EXTERIOR INTERIOR 0
EXTERIOR INTERIOR
a a
5 m
3 2 3 2 E?
o 3 0 0 o o
8 W. o
1 Q oa
o El oE Sd d
E a w i
a N N Q j
d
DATE. 3120112 z
0
sca.E: N.T.S. 5
DWG. BY. JK m
2 VER17CAL CROSS SECTION r 3 VERTICAL CROSS SECTION Gwc. ar: LFS
3 Masonry s0 v Masonry sill IXUWING No.: rc
FL-16842.14 0n
sNEEr 3 ov 5
2X SUB
BUCK
MASONRY
OPENING
4"
TYP.)
4 (TYP•)
2X BUCK ANCHORING
8iL
a CONCRETE ANCHOR NOTES:
0 1. Concrete anchor locations at the comers may be ocyusted to mofntatn the mfn.
edge distance to mcdarjolnts.
2. Concrete anchor locations noted as "MAX. ON CENTER' musf be ocFXsted to
Z maintain the min. edge distance to mortarjoints, addtionalconcrete anchors
Z may be mgL*edtoenswe the "MAX. ONCENTER' dhnenston are notexceeded.
a 3. Concrete anchor table:
o
m WOODSCREW INSTALLATION NOTES:
z 1. Maintain aminimum 5/8' edge dMance. 1"enddistance, & I"o.c. spacing of
woodscrews to prevent the splittingofwood.
ANCHOR ANCHOR.'MIN. CLEARANCE N. CLEARANCE.
TYPE SIZE EMBEDMENT 70 MASONRY 76 ADJACS
ANCHOR. .:
rrW
TAPCON
ELCO aULTRACON 1/4' 1-1/P 1' 4'
i R
h U
6 O
c s . F — N
TYP.) rT i T\\\ o nUN•
8(flP.) ^ v -- i
Em zSeo
FRAME
2X SUB
BUCK
MASONRY
OPENING
F 2X BUCK
G 1XBUCK
L STEEL STUD
TYP.
FRAME ANCHORING
ro e yg 9otavoa " maaT
i EE'L az
a.
a
ALE N.T.S.
VC. BY: JK m
W. ar: LFS 3
NO NO.: [C
FL-16842.14 0
im 4 of 5 " A
BILL OF MATERIALS
rrEM3 mcRIPTR7N MATERW
A 1 X BUCK (SG >= 0.42) WOOD
B 2X BUCK (SG >= 0.42) WOOD
C 1 /4" MAX. SHIM SPACE
D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL
E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE
F 10 X7' PPH SMS (1-1/7' MIN. EMBEDMENT) STEEL
G 1 /4" X 23/4" HH ELCO OR ITW CONCRETE SCREW WOOD
K 6 X 1-1/4" PFH SMS STEEL
L 10 PPH SELF -DRILLING SMS STEEL
X STEEL STUD Min. Thk .033" (ASTM A653 GRADE 33 Fr33 Id min., Fu=45 W min.) STEEL
1 FRAME PVC
2 SASH' PVC
3 GLAZING BEAD' PVC
4 GLASS SETTING BLOCK PVC
5 PULL STILE* PVC
6 LOCK STILE' PVC
7 MEETING STILE' PVC
8 ANTI -LIFT & SILL TRACK`
10 GLAZING SILICONE (DOW 11991 jjAgLUM1411REINFORCEMENT (6063 - T5)
LOCK ASSEMBLY (TRUTH)
THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY
EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS".
7/8" O.A. GLASS THK.
1/8"ANNEALED GLASS
AIR SPACE
1 /8" ANNEALED GLASS
R
Gl GLAZING DETAIL
9
fn
o- I 0.22'
0.05'
0.56"
GLAZING BEAD
446E
FRAME
444F
0.93" -(---1
1"
6 LOCK S71LE494E
1.23" - l
F-
I
0.09"
REINFORCEMENT
480
1
O F .
48"
L
I I- 0.07'
8 ANT1.UFTRSILL TRACK206
0.28 -1
a 1`
O O
2 SASH424E
0.9•
5 PULL SnLE4753
Off. •• ••
t'_
nn
i N''• g O: °o
Y.. ` Fran
n z
N O
E\\
V
g E m z v o
c )
9 a. NQro mOtmda
au:
E oz
d . w cV
MEETING w
493B rc. BY. JK
IK. BY: LFS ;
CAWING NO.: a,
FL-16842.14 c
d
IEEE 5 OF 5 Q
9/28/2018 r Florida Building Code Online
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Scats & Facts I Publications ( Contact Us ' BCIS Site Map I Links I Search
b
a
ry jl ; ;Product Approval
qq {
USER: Public User
tt iti;Fxm
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL16842-R4
Revision
2017
Approved
0
NewSouth Window Solutions
4901 oak fair blvd
tampa, FL 33610
513)284-0129
danochstein@newsouthwindow.com
Vivian Wright
rickw@rwbldgconsultants.com
Windows
Horizontal Slider
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
O Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan 1. King, P.E.
U Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL16842 R4 COI (c) Certificate of independence.pdf
Standard Year
AAMA/ W DMA/CSA 101/I. S.2/A440 2008
AA MA/ W DMA/CSA 101/I. S.2/A440 2005
AAMA/ W DMA/CSA 101/I. S. 2/A440 2011
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2005
ASTM E1996 2009
TAS 201, 202, 203 1994
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf°/a2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 1/5
9/28/2018
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page =
Method 1 Option D
04/11/2017
10/20/2017
10/23/2017
12/12/2017
Page 1 / 20 0
FL # Model, Number or Name Description
16842.1 a. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window
utilizing a Nail Fin Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.1.pd
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.1 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.1.q f
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.2 b. Series 9000 Model 9500 Slider XO Extruded Vinyl "Non -Impact" Horizontal Sliding Window with
Flange Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.2&df
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.2 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.2.12df
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.3 c. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a
Impact Rated Nail Fin Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.3.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.3 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 66842.3.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.4 d. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window with Flange
Impact Rated Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.4.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.4 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.4.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.5 e. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a
Impact Rated - HVHZ Nail Fin Installation (XO or OX configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.5.Qf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant. Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.5.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.6 f. Series 9000 Model 9550 Slider XO Extruded Vinyl "Impact' Horizontal Sliding Window with Flange
Impact Rated - HVHZ Installation (XO or OX configurations)
hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d°/`3d 2/5
9/28/2018 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.6.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.6 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.6.gdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.7 g. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact' Horizontal Sliding Window
XOX utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.7.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.7 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.8 h. Series 9000 Model 9500-3 Slider Extruded Vinyl "Non -Impact" Horizontal Sliding Window with
XOX Flange Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.8.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.8 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.8.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.9 i. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a
XOX - Impact Rated Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.9.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.10 j. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window with Flange
XOX - Impact Rated Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.10.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.10.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.11 k. Series 9000 Model 9550-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window utilizing a
XOX - Impact Rated - HVHZ Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (¢) Inst 16842.1i,pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R4 AE (12) Eval 16842.11.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.12 I. Series 9000 Model 9500-3 Slider Extruded Vinyl "Impact' Horizontal Sliding Window with Flange
XOX - Impact Rated - HVHZ Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16842 R4 II (b) Inst 16842.12.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.12.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.13 m. DuraGard Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window
utilizing a Nail Fin Installation (XX, configuration)
https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA°/"3d%3d 3/5
9/28/2018 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16842 R4 II (b) Inst 16842.13.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.13.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.14 n. DuraGard Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window (XX,
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (11) Inst 16842.14.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.14 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.14.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.15 o. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window
utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.15.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.15.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window with
Flange Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 1 8842.16.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.16 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.16.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.17 q. Sashlite Slider XX Extruded Vinyl "Non -Impact' Horizontal Sliding Window
utilizing a Nail Fin Installation (XX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.17.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.17.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.18 r. Sashlite Slider XX Extruded Vinyl "Non -Impact" Horizontal Sliding Window (XX,
configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.18.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.18.pgf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.19 s. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window
utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (b) Inst 16842.19.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.19.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
16842.20 t. Sashlite - 3 Slider XOX Extruded Vinyl "Non -Impact' Horizontal Sliding Window (XOX,
configuration)
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 4/5
9/28/2018 Florida Building Code Online
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16842 R4 II (¢) Inst 16842.20.E
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R4 AE (b) Eval 16842.20.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
Go to Page
Back Next
0® Page l/ 2 0 0
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. QgpYLght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. if you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
0hsck
eS . 0
Safe
sechu'Itynt L- ucs^ ;
hftps://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQumXyGur83s42hZkY3sC4ZA%3d%3d 5/5
W S 0 UIt
1 FEWINDOWSOLUTIONS
4901 Oak Fair Blvd., Tampa, FL 33610
DvraGard - 3 Slider XOX
NON -IMPACT"
GENERAL NOTES
1. This product has been evaluated and is in compliance with the 6th Edition
2017) Florida Building Code (FBC) structural requirements excluding the
High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor
embedment to base material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind bome debris protection this product is
required to be protected with an impact resistant covering that complies
with FBC Sections 1609.1.2 & R301.2.1.2.
4. For 2x stud framing construction, anchoring of these units shall be the some
as that shown for 2x buck masonry construction,
5. Site conditions that deviate from the details of this drawing require further
engineering analysis by a licensed engineer or registered architect.
TABLE OF CONTENTS
SHEET# DESCRIPTION
I Typical elevations, design pressures & general notes
2 Horizontal and vertical cross sections
3 Buck & frame anchoring
4 Bill of materials, glazing details and components
11 T MAX. OVERALL FRAME WIDTH
X 0 X
MAX. DAYLGNL.. MAXDAYLIGHT DESIGN PRESSURE
FRAME'
DIMENSION .
OPENING
DIMENSION
OPENING
DIMENSION
GLASS;
TYPE, PSG
F:(OPERABLE).
112.0" x 63.25" 52.25" x 56.5' 25.5' x S6.5" G1 30.0 30.0
It 111111/ r
i
Q-_ Ja n
a:o oW
it/rr 1*11 11 z o zip o
U.N ..Z
n
N
v Z O Z UE Gt 9m opLC WmgmaLai
x 4
E ofoq4i3 ca
2
NIn N N Q I
m
N z L
z c
TE: 4 17 12 i
ALE: N.T.S.
G. BY: JK
K. BY: LFS 3
AWING NO::
FL-16842.16
A
Err _L of 4
11111 flit
4
F1_' M
Z nIt2Ea . Z
loin
1 A Z
ism
C f o
X F Eag _imoo
0 qz 9 d 'a a22o` v!a aa
22
zav . 23 p 10 8 `la:
7 aU
V)
O
2W3JYJ2VERMALCROSSSECTION2JV)
2 IX Buck Masonry Construction N vi ~O
1-1/4" MIN. B EXTERIOR
INTERIOR o
x
NL)
rccc
EMB. FYP.) o Ir
G1 a a
m
C 20 B
1 3 INTERIOR
GI 4 6 a a 11 00
12 1
N N
u,
W W p
Q El25 17
C
G m
G m
oo
26 F
D
E oe m
F EXTERIOR a. N _ oZ
E D
5 12 6 a. 4. aTE: 4117112 =
o
SCALE N.T.S. 5
2
DWG. BY. JK m1HORIZONTALCROSSSECTION3VERTICALCROSSSECTIONCHK. BY.. LFS 3Q2XBuckMasonryConstruction22XBuckMasonryConstructionDRAWMCNO.: Y
FL-16842.16 0
N
SHEET _L OF ¢
S o n
MTG. RAIL
X.
Jllfit 11 mon zo
gr 9mcowa
n Ma:a.
ZX SUB
V a LL d
E v W
BUCK
A MASONRY Ic
OPENING o w
F En
V
m
N
U3ZN Q
O m
MTG. RAIL
s
1XBUCKANCHORING
p' jTYP.)
P• —I j m
yP)
s
Uu aua 11Ty
ox O o
NoCCpWWZO
e
tN
FRAME a o
W
O
CONCRETE ANCHOR NOTES: v I. Concrete anchor locations at the comers may be adjusted to maintain the min. MASONRY
j j z
mN
M edge distance tomodarlofnts. OPENING
q 2. Concrete anchor locations ratedas "MAX. ONCENTER" must beadjustedto
Z maintain the min edge distance to mortar joints, oddttonol concrete anchors
may be required to ensure the "MAX. ON CENTER" dimension ore not exceeded.
3. Concrete anchor table: z
O oNzZa
DATE, 4117112 i
scnsE N.T.S. rwV 3
ovrc. BY: JK m
FRAME ANCHORING 3DMncNO,
LFS
WOOD SCREW INSTALLATION NOTES: FL-16842.16 ro1. Maintain a minimum5/B"edge distance, 1"end distance, d I"o.c. spacingof p
SHEET 3 pF ¢
wwoodscrewstopreventthesplitsingofwood.
1YP 4"
iYP,
Tl'P.
TYP.)
O
ANCHOR ANCHOR M1N MIN CLEARANCE MIN: CLEARANCE
TYPE SIZE FMBEDMENT ZTD MASONRY 10 ADJACFM ;;-
r EDGE-..;:: ANCHOR
TAPCON
ELCO e 1 4" 1-1/4" 1" 4' UITRACON
VIF2XKK
TYP
I I I I I
BILL OF MATERIALS
NFM # DESCRIPTION MATERIAL
A iX BUCK (SG >= 0.42) WOOD
B 2X BUCK (SG >= 0.42) WOOD
C I /4" MAX. SHIM SPACE
D 1 /4" X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL
E MASONRY - 3,000 PSI MIN. CONCRETE CONFORMING TO ACI
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE
F 10 X 2-1/7' PPH SMS (1-3/8" MIN. EMBEDMENT) STEEL
H 1 /4" X 3-1 /4" PFH ITW CONCRETE SCREW STEEL
1 EXTRUDED VINYL FRAME. (444) RIGID PVC
2 EXTRUDED VINYL FLANGE INSERT' (422A) RIGID PVC
3 EXTRUDED VINYL HANDLE STILE • (475B) RIGID PVC
4 EXTRUDED VINYL LOCK STILE • (494B) RIGID PVC
5 EXTRUDED VINYL KEEPER STILE. (493B) RIGID PVC
6 EXTRUDED VINYL GLAZING BEAD • (446B) RIGID PVC
7 EXTRUDED VINYL TOP RAIL • (4248) RIGID PVC
8 EXTRUDED VINYL BOTTOM RAIL ` (424B) RIGID PVC
9 VENT STOP (ASHLAND)(# 10821) RIGID PVC
10 ANTI-UFT TRACK' (206) RIGID PVC
11 SLIDER TRACK* (206) RIGID PVC
12 REINFORCEMENT (484) ALUM.
17 ROLLERS
18 LOCK ASSEMBLY (TRUTH) STEEL
20 GLASS SETTING BLOCK
22 8 X 1-1/4" FH SMS STEEL
23 8 X 1 /7' PH SMS STEEL
THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY
EXTRUDERS LICENSEES IN "AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS".
7/8" O.A. GLASS THK.
3/16" ANNEALED
AIRSPACE
3/16" ANNEALED
FOAM SPACER
1/7' GLASS 8RE L\ GLAZING SILICONE
Gl GIAIING BEAD
r— 1.47' —1
0
0
r TOP RAIL
T FRAME
0
8 BOTTOM RAIL
w
mod); @:O
mM
pm
Em
o
m o Ld0oa
0.07' m maifa112
s4 6Ecz
HANDLE STILE
z
5 KEEPER STILE
o
z
CDczmwo
LL
o o
Z FLANGEINSERT o
a
m
a
4 LOCK STYLE
ue N.T.S. 3
c. BY: JK m
K. BY: LFS 3
AWWI: ND.: R
v
FL-16842.16 0N
cET 4 OF 4