Loading...
HomeMy WebLinkAbout307 Tall Pine Ln - BR18-004583 - REROOFCITY OF SANFORD NOV 2 0, 2pjg; BUILDING & FIRE PREVENTION PERMIT APPLICATION i _ 0ApplicationNo: ""C Documented Construction Value: S 6C)CO, 00 Job Address: / ( l Historic District: Yes NoR0 Parcel ID: I Q — a(- Residential;E oCommercial Type of Work: New Addition ] A,,lteration Repair ElDemo Change of Use Move Description of Work: — Y2Jo ( ur)S r0 l; a s-_Abyoc" Plan Reviewsc Contact Person: v ` 1 , Title: Phone:4U- 0 3 81OFax: Email: Property Owner Information Name Phone: — C' '7 7 ' V C) Street: Sa l Resident of property?: City, State Zip: Name ,10M Street: City, State Zip: Name: Street: City, St, Zip: Bonding Company: Address: r Info Y& irke: Fax: y State License No.: Architect/Engineer Information Phone: Fax: E-mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 5" Edition (2014) Florida Building Code Revised: June 30, 2015 Permit Application NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance ofpermit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owne A ent / Date Sign of Contractor/Agent Date His IT Lu Owner/Agent •s Personally Known to Me or Produced ID Type of ID Print ;Antr*tor/Agent's CARAL. LARACUENTE c* Commission # GG 208031 t a= Expires April 16, 2022 TFOFF p' Bp Thro Troy Fain hnuffi a 80"W70i9 Contractor/Agent is ersonally Known to Me or Produced ID Type of ID BELOW IS FOR OFFICE USE ONLY Permits Required: Building Electrical Mechanical Plumbing[] Gas Roof Construction Type: Total Sq Ft of Bldg: Occupancy Use: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No APPROVALS: ZONING: ENGINEERING: COMMENTS: of Heads UTILITIES: FIRE: Flood Zone: of Stories: Plumbing - # of Fixtures, Fire Alarm Permit: Yes No WASTE WATER: BUILDING: Revised: January 1, 2018 Permit Application POWER OF ATTORNEY Date: I hereby name and appoint of TOTAL HOME ROOFING to be my lawful attorney. In fact to act for me and apply to the Building Department for a RE -ROOF permit. For work to be performed at a location described as: } Parcel ID: _ U Subdivision: oLqd Owner of property and address: 6-1 And to sign my name and do all things necessary to this appointment. V ROBERT DON CCC1330489 Type or prin me of certified contractor and license number) Signature of certified contractor) The foregoing instrument was acknowledged before me this a day of % of 20 by Robert Donovan, who is personally known to me. WA L UUTACUENTEStateofFlorida =; rya,#GG208W1a: County of Seminol . 0 8% 7M Notary signatu Grant Malo , Clerk Of The Circuit Court & Comptroller Seminole County, FL Inst #2018f29407 Book:9248 Page:1256; (1 PAGES) RCD:•11/14/2018 2:42:23 PM REC FEE $10.00 THIS INSTRUMENT PRE% ED BY: Name: /l Address: NOTICE OF COMMENCEMENT Permit Number. Parcel ID Number. TO — CD {- Vie) , /v The undersigned hereby gives notice that improvement will be made to certain(Jreaall property, andInaccordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. of the property and street address if available) 2. GENERAL DESCRIPTION OF Re - roof Onllv 3. OWNER INFORMA Name and address, Interest in property: n Fee Simple Title Holder (if other than owner listed above) Name: J1 Address: 4. , CONTRACTOR: Name: Total Home Properties DBATotal Home Roofinc Phone Number: 407-960-3810 Address: 201 W State Rd. 434 Winter Springs, FL 32708 Suite A 5. SURETY (if applicable, a copy of the payment bond Is attached): Amount of Bond: 6. LENDER: Name: Phone Number: Address: 7. Persons within the State of Florida Designated by Owner upon whom notice or other documents maybe served as provided by Section 713.13(1)(a)7., Florida Statutes. Phone Number: 8. In addition, Owner designates of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b), Florida Statutes. Phone number: 9. Expiration Date of Notice of Commencement (The expiration Is 1 year from date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. a Id, 6- Owner Si ture of Owner or Lessee, or Owm Owner'sorLessee's (Print Name andProvide Signatory's TldelOffice) AuthonzedOfficer/Director/Partner/Manager) UR—a StateofCountyof 11' V\ l T , ,J1 ( The foMgolngumentwasak *wledged before me this day of V ' I , 20' by . Who is personally known to me 0 OR ^ O me ofpersonmaidnstatementCtiwhohasproducedidcationttaofidentificationproduced: V CARA L LARACUENTE s Commission # GG 208031 Notarysignature P Expires Awl16.2= R°' Bwded1ftwTMyrbialnswM800Q%$-70i9 M 4jrM ,}G/'i01 MINE BREVARD COUNTY OFFICE 321- 452-9223 TOTALH O A u ORANGE & SEMINOLE COUNTY OFFICE 407- 960-3810 m VOLUSIA COUNTY OFFICE 386- 233-3244 NAME: j,1tJ Z STREET: 3o- °i-,Li- Pim& CCC1330489 CITY/ STATE/ZIP: ^ A HOMEPHONE: 5'fN,W A 4 _ CELL PHONE: _ L321 T 1J2.io EMAIL: tf.. a hv; hMkROOFDueCaretakentoprotecthomeexterior, shrubs and landscaping. Includes labor to remove existing roof and haul off. Includes Dumpster. Roll off dumpster for paver driveways. Includes inspecting deck for damage and renailing to code with 8D ring shank nails. Includes saving gutters, soffit, fascia on existing home (some damage may occur in construction):i'' l Includes replacing ridge vents. Includes replacing existing drip edge in choice of color. DRIP EDGE COLOR INT Includes 1 1/4" roofing collated nails. Includes installing new shingles in choice of color. SHINGLE COLOR INT Includes replacing all lead boots and goose vents (does not include gas related vents). Includes new galvanized metal in all valleys. Includes Starter Shingle and Ridge Cap per Code. Includes obtaining and posting permit with local jurisdiction. Includes magnetically sweepingjob site, cleaning out gutters and hauling away debris. MATERIAL ARCHITECTURAL ASPHALT LIFETIME SHINGLES 130MPH UNDERLAYMENT PEEL&STICK ,- p ,r A/r /.,, 7t % J1 T!w`i/ y MISC fJ ' C)z V,?AJ IS' 4 f= INCLUDES LABOR AND DUMPSTER TO REMOVE I LAYERIS) OF SHINGLES. ADDITIONAL LAYERS WILL COST $&-10— PERLAYER ADDITIONAL LAYERS INT Deteriorated existing decking replaced at $ (Jc per sheet of plywood 2 S % jJ f• j L Deteriorated existing decking replaced at $ `£ per linear ft. WOOD ACKNOWLEDGMENT INT Does not include painting to match Does not include any stucco repairswhere deterioratedFlashing had to bereplaced. WARRANTIES WArt>i'-F r" Iri 7 - - INCLUDED Worry - Free Platinum inclusive $ Flat roofs carry a ^ CUSTOMER WAIVES INTERIOR DAMAGE PREANSPECTION • Customer Initials (f T' rAnyinteriordamagewhichoccursduringconstructionwillnotbecoveredINCLUDES NEW WIND MITIGATION INSPECTION TOTALj? EASY FINANCING OPTIONS Monthly Payment 9. 90% APR Is 12 months NO INTEREST Is Through Wells Fargo Bank with approved credit. Financing must be complete ®prior to start of project. f CUSTOMER SI NATURE DATE TOTAL HOME ROOFING DATE I HAVE READ AND UNDERSTAND THIS PROPOSAL, THE TERMS AND CONDUTIONS, AND ALL DOCUMENTS REFERENCED THEREIN AND AGREE TO BE BOUND BY THEIR TERMS. ACCEPTANCE OF PROPOSAL: The above prices, their specifications and conditions are satisfactory and are hearby accepted. Contractor is authorized to do the work as specified. By signing Customer acknowledges that Customer is owner of the property where work is to be performed. ALL PAYMENTS ARE DUE UPON COMPLETION OF THE PROJECT. Any delay in payments mayresult in 1.S% interest per 30 days. Wind Mitigations are not considered part of the project but offered as a service to our customers through a thirdparty certified licensed inspection company and shall not be used as reason for any delay of final payment. This agreement constitutes the entire contract by and between contractor and owner and parties are not bound by oral expressions or representation by any party or agent of either party. 6/15/2018 Florida Building Code Online n RL01410A Do RTM6NT OF Business & Professionai Regulation Florida Diu Ctt Ikr . P.aa nal iim pr IkO,FFIGE OF THE S> GRETARY BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge Product Approval USER: Public User Stats & Facts I Publications I FBC Staff I e Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By FL10674-R13 Revision 2017 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 419)376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Arc Professional Engineer Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE-59166 UL LLC 05/16/2020 John W. Knezevich, PE Validation Checklist - Hardcopy Received https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEBFhs7tvJgZew%3d%3d 1/3 6/15/2018 Florida Buidding Code Online Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL10674 R13 COI 2017 01 COI Nieminen.pc Standard ASTM D3161 ASTM D3462 ASTM D7158 Method 1 Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017' FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, start Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R13 II 2017 10 FINAL Approved for use outside HVHZ: Yes SHINGLES FL10674-R13.pdf Impact Resistant: N/A Verified By: Robert 3. M. Nieminen I Design Pressure: N/A Created by Independent Third Part) Other: Refer to ER, Section 5. Evaluation Reports FL10674 R13 AE 2017 10 FINAL SHINGLES FL10674-R13.pdf Created by Independent Third Part Back FN..tl Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Stat Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-recc mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.4I 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If y address, please provide the Department with an email address which can be made available to the public. To determine if you are please click here . Product Approval Accepts: L ® ECIIECR M Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2boQT%2b6w7ahRegICQ8ucR6ixEBFhs7tvJgZew%3d°/a3d 2/3 QOTRINITYIERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 740)404-7829 EXTERIOR RESEARCH & DESIGN, LLC. Certificate ofAuthorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 203) 262-9245 Evaluation Report 037940.02.12-R8 FL10674-1113 Date of Issuance:02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert JI M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 y The facsimile authorized 4n ..... nen, P.E. on 10/09/2017. Thsnot serve as an Nieminen, electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. I TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic® and Supreme® are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 DevonshireT' are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration®, TruDefinition® Duration®, Duration® Premium Cool, TruDefinition® Duration Designer Color Collection, TruDefinition®Oakridge®, Oakridge® and WeatherGuard® HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shingles: 4.2.1 Berkshire® Hip & Ridge Shingles, High Ridge, WeatherGuard® HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgeT1 Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt RoofShingles Revision 8: 10/09/2017 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (VUit = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 614320-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: Berkshire shingles require minimum five (5) nails per shingle. WeatherGuarde HP shingles require minimum six (6) nails per shingle. Devonshire*" shingles require minimum six (6) nails per shingle. Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Felt underlayment Deck Self -adhered WeatherLocke underlayment Drip, edge Drip edge Nails located 2"-3"from eave Install first Self-sealing adhesiveStarterStripedpositionalongeaveshingle with \ 6" removed Starter Strip shingle overhangs eaves and rakes Fat underlayment / Deck Self -adhered WeatherLockS underlayment li Drip edge edge Nails located 2"- 3" from lave adhinstal rustStarterStripPlusSosnedalongaavewith 6' removed positioned Starter Strip P rs overhangs eaves and rakes 1/4"-3/4" Exterior Research and Design, L-C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing — Classic®& Supreme: Normal Mansard or Area porn Wind Areas High Wind desvanes y Area pare vientos normales Areas vientos fuertes r IAI t., 1. IB 2• t" tt• tt• 5"Exposure Exposici6n 6.2.7 Minimum Nailing — Berkshire®: Stanaara rastenlne Pattern Normal Mansard or Area pare Wind Areas High Wind desvanes y Area pare vientos normaies Areas Wanton fuertes tzt t2t 6 5/8• Exposure Exposici6n Sealant strip Le Cra de sellador sa>•a® e - a .-+ e e att8%" I 81h. 8W I 8%" t" 6-Nail Fastening Pattern Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 4 of 8 6.2.8 Minimum Nailing — Devonshire"': 1'= I 7" 8" $" 1 8° I 7- I _fin a,wn 5.5/8- exposure Sealant locationFxposia6nde5 -5/8 pulg Ubicaci6n del sellador Standard 6-Nail Fastening Pattern TRINITYJ ERD WE-- W = i II__ IllI LEA Ten 1" Spots of Asphalt Roof Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition• Duration Designer Color Collection: 4-Nall Fastening Pattern sw•Nailat Wtoi ns m wlAw Mail, lypiCal r +r +^ w-.c •. • i t .-.o • o.-- t • F1 F F --j Standard Fastening Pattern 6-Nall Fastening Pattern sw•raiaoasa" W" WM Na141yp" r +r +r +^ F1 F F1 rvidnsdru ui .xeep Diupe rdxennig rdueni Exterior Research and Design, U.C. Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVH2 EVALUATION Owens Corning Asphalt Roof Shingles 6-Nail Fastening Pattern Evaluation Report 037940.02.12-118 FL10674-1113 Revision 8: 10/09/2017 Page 5 of 8 6.2.1 Minimum Nailing —TruDefinition' Oakridge®,Oakridge®: 4 Nall Pattem Esquema cat 4 claws Standard Fastening PatternI l TRINITY (ERD 6 Nail Pattern Esquema con 6 claws 1• r s— 1r 1r Nalls 5SJV' Exposum C a0s5 sAr Exposwo Erposiddit de 66/8pulg Exposteft do 66/8 pulpFastening for Slopes Greater Than 21:12 funNtl/ a hstsnlnemoa MEN Nall, 7ypi7 12' ov 7" Spots of lbpnaRRoofng C. ffl Mansard or Steep Slope Fastening Pattern 6. 2.1 Minimum Nailing — WeatherGuard® HP: 6- Nail Fastening Pattern mole Ode View WWII* hmbwAd s. ::; e• Ilistwrr7lnw* FMI Wito Ci1 ea erin.. de flFes le Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-118 Certificate of Authorization #9503 6i" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 6 of 8 6_3 Hip & Ridge Shingles: a a 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing— Berkshire® Hip & Ridge and High Ridge: Fig. 1 Q PievalanglMnd Direction A Nall s—`i A Q I I A I I A I I IQII I I I I A I I I I a -- Exposure Fig. 2 TopM w 9daMew Naps Nails l T Top Laminated r a- Piece 1' t' I ggISII1 a' i II11 6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Ridge: Fig. C Hip & Ridge Shingle Fastening Topvlaw Nails Nails r r' r" r 1. 6 EIPMM Iw— 1r Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6' EDITION 12017) FBC NON-HVHZ EVALUATION FL10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 6" Exposure J Fasten 711," Cover Exposed Fasteners with Roof Cement 0 I TRINITY1 ERD Standard ,_• Fastoning Pattern r r- 1•;r _l , I.1° 12° 1 Sealant 71h 6" Exposure 6.3.6 Minimum Nailing — DuraRidgeT" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Top ViewWeonplan I^ Vlsn superior I' H NA 1 Cl- ovma nscoiningSUMN81' Co. 8 d I uI 12" 7. LABELING: 7. 1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7. 2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8: 10/09/2017 Page 8 of 8 y BCIS Home li Log In User Registration Hot Topics 1 Submit Surcharge t Stats & Facts j Publications ; FBC Staff SCIS Site Map Links f search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL17420-R4 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Owens Corning One Owens Corning Parkway Toledo, OH 43659 740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden D Validation Checklist - Hardcopy Received Certificate of Independence FL17420 R4 COI OCR14004 4 2017 FBC Eval Report ProArmor final odf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1507.1.1 Product Approval Method Method 2 Option B Date Submitted 09/30/2017 Date Validated 10/03/2017 Date Pending FBC Approval 10/04/2017 Date Approved 12/12/2017 Summary of Products FL # Mod1.Number or Name Description 17420. 1 ProArmor Synthetic underlayment for use with asphalt shingles in steep slope roofing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17420 R4 II OCR14004.4 2017 FBC Eval Report ProArmor final.odf ApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL17420 R4 AE OCR14004.4 2017 FBC Eval Report ProArmor final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please clickhere . Product Approval Accepts: NN Certificate of Authorization No. 29824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 6T" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owens Corning Parkway Toledo, OH 43657 800)438-7465 www.owenscorning.com Quality Assurance: Intertek Testing Services NA, Inc. (QUA1673) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year Intertek Testing Services NA Ltd. (TST1509) 102389161COQ-002A AC 188 2012 Intertek Testing Services NA Ltd. (TST1509) 102389161 COQ-003b ASTM E 108 2011 Intertek Testing Services NA Ltd. (TST1509) 102389161COQ-004 ASTM D 226 2009 PRI Construction Materials Technologies (TST5878) OCR-259-02-01 ASTM D 1970 2015a PRODUCT DESCRIPTION AND APPLICATION ProArmor1°° A mechanically attached, synthetic underlayment consisting of a woven polypropylene base with a non -woven polypropylene laminate on the topside of the underlayment, and a coating on the back side (nominal weight = 2.15 Ib/1002). The underlayment shall be used an alternative to ASTM D 226, Type II roofing underlayments and has demonstrated a minimum tear strength of 20 pounds when tested in accordance with ASTM D 1970. The product is supplied in 9.2-sq rolls with nominal dimensions of 4-ft x 250.5-ft. Unless otherwise noted, the following application details shall be followed for New and Existing construction. See manufacturer's installation instructions for further detail. Roof Deck: The roof deck shall be constructed of closely fitted wood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than'/8" gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions. Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. OCR14004.4 FL17420-R4 Page 1 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC ProArmorTPA 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Roof slope limitations, shall be in accordance with FBC requirements. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 9) The underlayment shall not be installed over existing roof coverings. 10) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 11) The underlayment shall not be exposed on the roof deck for longer than 30 days. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. G PFtY R F No 74021 3 STATE OF :U 0 N Ae 00' CERTIFICATION OF INDEPENDENCE 2017.09.30 15:21:14 04t00t Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14004.4 FL17420-R4 Page 2 of 2 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. laue.•0iee at BCIS Home Log In i User Registration t Hot Topics j Submit Surcharge Stats & Facts i Publications FBC Staff BCIS Site Map f Links I Search i dbprda c` emsr; Product Approval Y' 5 USER: Public User 00 rat Product Approval Menu > Proeucc or Application Search > Aoelication List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL9777-R11 Revision 2017 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 740)404-7829 greg,keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Zachary R. Priest PE-74021 UL LLC 12/31/2020 Locke Bowden Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard ASTM D 1970 ASTM D 226 ASTM G 155 TAS 103 UL 1897 Equivalence of Product Standards Certified By Sections from the Code Year 2015 2009 2005 1995 2012 Product Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 1111 II OCR14002 8a 2017 FBC Evaluation Reoort Weatherlock Non-HVHZ.odf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ Ddf Created by Independent Third Party: Yes 9777.2 Weatherlock G (High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 RI1 II OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. FL9777 Rt t AE OCR 4nn2 as 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Created by Independent Third Party: Yes 97773 Weatherlock MAT Waterproofing Underlayment Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL9777 R11 II OCRI4002 8b 2017 FBC Evaluation Report Weatherlock HVHZ.Ddf Verified By: Zachary R. Priest 74021 Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002 8b 2017 FBC Evaluation Reoort Weatherlock HVHZ.pdf Created by Independent Third Party: Yes 19777.4 1 Weatherlock MAT I Waterproofing Underlayment I Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.Ddf Created by Independent Third Party: Yes 19777.5 1 Weatherlock Metal I Weatherproofing Underlayment' Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use Installation Instructions FL9777 R11 II OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002.6a 2017 FBC EvaluationReoort Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 19777.6 1 Weatherlock Metal I Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. Installation Instructions FL9777 1111 II OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.odf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002.8b 2017 FBC Evaluation Re oorrt Weatherlock HVHZ.odf Created by Independent Third Party: Yes 9777.7 Weatherlock Specialty Tile & Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II OCRi4002,8a 2017 FBC Evaluation Report Approved for use outside HVHZ: Yes Weatherlock Non-HVHZ,odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-142.5 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002 8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487.1824 The State of Florida is an AA/EEO employer. Copyright 2007.2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records, if you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.2751), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click hem. Product Approval Accepts: du'iC Credit Card Safe srcurta•`r+titraucsv` jr, 41 lr 0"Z14-:4P 69116 TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 813) 480-3421 FLORIDA BUILDING CODE, 6TH EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway Toledo, OH 43657 800) 438-7465 www.owenscorning.com Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) PRI Construction Materials Technologies (TST5878) Report No. N EI.039-02-01 NEI-042-02-01 REV2 NEI-045-02-01 NEI-045-02-01 NEI-053-02-01 NEI-053-02-01 NEI-093-02-02 OCF-213-02-01 OCF-237-02-01 OCF-252-02-01 OCF-252-02-01 OCF-253-02-02 OCF-272-02-01 OCF-296-02-02 PRI Construction Materials Technologies (TST5878) OCF-297-02-01.1 PRI Construction Materials Technologies (TST5878) OCF-318-02-01 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 PRI Construction Materials Technologies (TST5878) OCF-321-02-01 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 PRI Construction Materials Technologies (TST5878) OCF-355-02-01 Determined to be equivalent to ASTM D 226-09, Type I and II Issued October 11, 2017 Standard ASTM D 1970 ASTM D 1970 TAS 103 ASTM G 155 TAS 103 ASTM G 155 ASTM D 1970 ASTM D 1623 UL 1897 ASTM D 4798 ASTM D 1970 ASTM D 1970 TAS 103 ICC-ES AC 188' ICC-ES AC 48 ASTM D 1970 ASTM D 1970 TAS 103 ASTM G 155 ASTM D 1623 UL 1897 UL 1897 Year 2015 2015 1995 2005a 1995 2005a 2015 2009 2012 2001 2015 2015 1995 2012 2012 2015 2015 1995 2005a 2009 2012 2012 OCR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein, CRift...EK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock@ Self -Sealing Ice & Water Barriers WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SIBS Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from Brentwood, NH or SIBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete tile installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@ G (High WeatherLock@ G (High Tear) is a self -adhered, underlayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREED{ TECHNICAL SERVICES, LLC PRODUCT APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing ice & Water Barriers Min. Roof Slope: 2:12 in accordance with the FBC Application: All underlayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9 Underlavment Svstem No.1 — WeatherLock Specialty Tile & Metal Only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch fd tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-Rl l Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GENERAL LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing ice & Water Barriers 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underiayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underiayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 61' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. J 1111111l/,I QG•\,\CE.NS•FS No 74021 STATE OF v O R \.. CERTIFICATION OF INDEPENDENCE 2017.10. 09:06:29 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. 4/17/2018 Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts ( Publications FBC Staff BCIS Site Map Links Search bW' da Product Approval USER: Public User Product Aooroval Menu > Product or ARglication Search > 82Ql atlon Lfst > Application Detail FL # FL10758-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 740)321-634S greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/13/2020 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL10758 R7 COI OCR14003 3 2017 FBC Evaluation Report Owens Corning Vents final.pdj Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvldAviteOY0%2bC3zFtrydg9NkhwZWZzJrupAl5CIMPWHQ°/a3d°/a3d 1. 4/17/2018 Florida Building Code Online Product Approval Method ' Method 2 Option B Date Submitted 09/30/2017 Date Validated 10/04/2017 Date Pending FBC Approval 10/08/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 10758.1 VentSure 4-foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation in Moisture Ridge Vents shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R7 II OCR14003.3 2017 FBC Evaluation Repo Owens Corning Vents final,pdfApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report Evaluation Reports FL10758 R7 AE OCR14003.3 2017 FBC Evaluation Repo Owens Corning Vents flnal.Ddf Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Roof Galvanized metal roof vent Vent With Exterior Louver Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R7 II OCR14003.3 2017 FBC Evaluation Repo# Approved for use outside HVHZ: Yes Owens Corning Vents final.pd Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 R7 AE OCR14003.3 2017 FBC Evaluation Repo Owens Corning Vents final.(df Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758 R7 II OCR14003.3 2017 FBC Evaluation Repo# Owens Corning Vents Pnal.pdApprovedforuseoutsideHVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to evaluation report. Evaluation Reports FL10758 R7 AE OCR14003.3 2017 FBC Evaluation Report Owens Coming Vents final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. C=yjight 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: IM ® RE Em Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dU.aspx?param=wGEVXQwtDgvl dAviteOYO%2bC3zFtrydg9NkhwZWZzJrupA15CIMPWHQ%3d%3d 2, Certificate ofAuthorization No. 29824REEK17520EdinburghDr Tampa, FL 33647 TECHNICAL SERVICES. LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September30, 2017 1 Owens Corning Parkway Toledo, OH 43657 800)438-7465 www.owenscorning.com Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year Architectural Testing, Inc (TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) 01-38660.05 TAS 100(A) 1995 Architectural Testing, Inc (TST1558) C1774.01-109-18 TAS 100(A) 1995 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) AVIG-005-02-01 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) AVIG-006-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-111-02-01 ASTM D 635 2010 ASTM D 1929 2012 ASTM D 2843 2010 PRI Construction Materials Technologies (TST5878) OCF-112-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-116-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OCF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies (TST5878) OHI-007-02-01 TAS 100(A) 1995 OCR14003.3 FL10758-R7 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. OWENS CORNING ROOFING AND ASPHALT LLCCREEKVentSure® Roof Ventilation TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION VentSureo 4-Foot Strip 1-1/4" x 14-7/8" x 48" low -profile attic ridge vent consisting of a two -layer nylon - Heat and Moisture Ridge polyester composite. Available with _or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. 48" Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maximum 16/12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (11-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a 1/4-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/z-inch galvanized ring shank nails shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2'/cinch galvanized ring shank roofing nails shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles OCR14003.3 FL10758-R7 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation TECHNICAL SERVICES, LLC VentSure'9 Low Profile 18" x 24" x 2-3/16" (32" x 23" flange base) static off -ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3. I, 1 onaaI r T I4Q I I BOrro ,w awe, o-ur v arr . " 1 I:'RW 980 RtCNI —T Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck (Minimum 18 nails per vent). Install baffle in Y.-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles OCR14003.3 FL10758-R7 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation TECHNICAL SERVICES, LLC VentSure01 Rigid Roll 5/8" x 11-1/4" x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun -bond polypropylene fabric. Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring %-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. 5) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 6) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 7) Installation of the roof assembly is outside the scope of this evaluation. 8) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. OCR14003.3 FL10758-R7 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT OWENS CORNING ROOFING AND ASPHALT LLC VentSure® Roof Ventilation The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. t1111$ R. • p/, QG.•G•E1VS c•FS, 201.7.09.30 No 74021 15:16:17 STATE OF : J 041001 itcs • 0 R t •••(j Zachary R. Priest, P.E. iS if N AI %.1' FloHda Organization No RegistrationANE9641021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14003.3 FL10758-R7 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. JOB ADDRESS: PERMIT # _LVS_S J Building & Fire Prevention Division RESIDENTIAL RE -ROOF SCOPE OF WORK Lei STRUCTURE TYP SINGLE FAMILY RESIDENCE/TOWNHOUSE O MOBILE HOME O APARTMENT/CONDOMINIUM RE -ROOF TYPE: O REPLACEMENT (TEAR OFF EXISTING ROOF AND REPLACE WITH NEW COMPONENTS) O RE-COVER (NEW ROOF INSTALLED OVER EXISTING ROOF k / DECK TYPE (PLEASE SPECIFY): 1 n I :) y PLEASE NOTE: ONLY 100 SQUARE FEET THE EXISTING DECK It-PERhITTED TO BE REPLACED" ROOF VENTILATION: O OFF -RIDGE DGE O SOFFIT OPOWERED VENT O TURBINES SKYLIGHTS: O YES XNO IF YES, PLEASE PROVIDE FLORIDA PRODUCT APPROVAL #: MAIN ROOF AREA ROOF SLOPE: O LESS THAN 2:12 2.12 - 4:12 O 4:12 OR GREATER TYPE OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL HINGLE I FL# 0 METAL FL# O MODIFIED BITUMEN FL# OTORCH DOWN FL# OINSULATED FL# O TILE FL# O OTHER: FL# ROOF EXTENSIONS (PORCHES, PATIOS, ETC.) **IF APPLICABLE** ROOF SLOPE: O LESS THAN 2:12 O 2:12-4:12 O 4:12 OR GREATER TYPE OF ROOF MANUFACTURER FLORIDA PRODUCT APPROVAL O SHINGLE FL# O METAL FL# O MODIFIED BITUMEN FL# O TORCH DOWN FL# O INSULATED FL# O TILE FL# 0 OTHER: FL# CITY 4 A NANFORD Building &Fire Prevention Division RESIDENTIAL RE -ROOF POLICY & PROCED URES FIRE DEPARTMENT PERMITTING REQUIREMENTS — NO PLAN REVIEW REQUIRED THIS DOCUMENT (SIGNED) ALONG WITH AN ACCURATE AND COMPLETED RESIDENTIAL RE -ROOF SCOPE OF WORK ARE REQUIRED TO BE SUBMITTED AS PART OF YOUR PERMIT APPLICATION. THE SCOPE OF WORK MUST INCLUDE ALL APPLICABLE FLORIDA PRODUCT APPROVAL NUMBERS FOR ALL ROOF COMPONENTS THAT WILL BE INSTALLED ON THE PROJECT. A PERMIT WILL NOT BE ISSUED WITHOUT THESE DOCUMENTS. COPIES WILL BE MADE TO POST ON THE JOB SITE. PROJECTS LOCATED IN THE SANFORD HISTORIC DISTRICT WILL REQUIRE PLAN REVIEW AND APPROVAL BY THE SANFORD HISTORIC PRESERVATION BOARD INSPECTION POLICY & PROCEDURES A FINAL ROOF INSPECTION IS THE ONLY INSPECTION REQUIRED FOR RESIDENTIAL (SINGLE FAMILY, TOWNHOUSE, MOBILE HOME, APARTMENT AND/OR CONDOMINIUM) RE -ROOF PERMITS. THE FOLLOWING IS REQUIRED TO BE PROVIDE ON THE JOB SITE: PERMIT CARD, POSTED IN A CONSPICUOUS AND WEATHERPROOF LOCATION COMPLETED RESIDENTIAL RE -ROOF SCOPE OF WORK COMPLETED AND NOTARIZED INSPECTION AFFIDAVIT ALL FLORIDA PRODUCT APPROVAL AND CORRESPONDING INSTALLATION INSTRUCTIONS PRODUCT APPROVAL SHALL MATCH WHAT IS ON THE SCOPE OF WORK) DIGITAL PHOTOGRAPHS (MUST INCLUDE THE PERMIT NUMBER OR ADDRESS IN EACH PICTURE) o EACH PLANE OF THE ROOF, SHOWING THE UNDERLAYMENT INSTALLED. o ROOF DECK NAILING PATTERN & SPACING (INCLUDING A MEASURING DEVICE OR RULER) o ROOF DECK NAILS USED (INCLUDING A MEASURING DEVICE OR RULER SHOWING SIZE OF NAILS) o UNDERLAYMENT PATTERN & SPACING (INCLUDING A MEASURING DEVICE OR RULER) o DRIP EDGE & VALLEY ATTACHMENT (INCLUDING A MEASURING DEVICE OR RULER) o SHINGLES INSTALLED, NAIL PATTERN AND LOCATION OF NAILS SKYLIGHTS (IF APPLICABLE) o DIGITAL PHOTOGRAPHS SHOWING ALL INSTALLATION COMPONENTS, PER FL PRODUCT APPROVAL o DIGITAL PHOTOGRAPHS SHOWING ALL REQUIRED FLASHING, PER FL PRODUCT APPROVAL FAILURE TO FOLLOW THESE SPECIFIC GUIDELINES WILL RESULT IN AN AFFIDAVIT PROVIDED BY A FLORIDA DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER), CERTIFYING FBC CODE COMPLIANCE BY PERSONAL INSPECTION. CONTRACTOR (OR OWNER/BUILDER) SIGNATURE: DATE: D City of Sanford Building and Fire Prevention RESIDENTIAL RE -ROOF INSPECTION AFFIDAVIT NAILING, SHEATHING, DRY -IN, FLASHING, AND ALL FINAL ROOF COVERINGS PERMIT #: _ Liz; ADDRESS: SGvk I e) 7i-'> ' , AS A(N) GENERAL, BUILDING, RESIDENTIAL, OR ROOFING CONTRACTOR, ENGINEER, ARCHITECT, OF F.S. CHAPTER 468 BUILDING INSPECTOR, I HEREBY AFFIRM, THAT ALL OF THE FOREGOING INFORMATION IS TRUE AND ACCURATE AND THAT ALL ROOFING COMPONENTS LISTED ON THE SCOPE OF WORK AT THE ABOVE REFERENCED ADDRESS HAVE BEEN INSTALLED IN ACCORDANCE WITH THEIR PRODUCT APPROVALS AND ALL APPLICABLE CODE REQUIREMENTS - SPECIFICALLY FLORIDA BUILDING CODE, EXISTING BUILDING. IN ADDITION I CERTIFY THE INSTALLATION MEETS ALL REQUIREMENTS FOR SECONDARY WATER BARRIER AND NAILING OF THE ROOF DECK, IN ACCORDANCE WITH THE HURRICANE RETROFIT MANUAL REQUIREMENTS (BASED ON F.S. CHAPTER 553.844). LICENSE COMPANY/CONTRACTOR: CONTRACTOR SIGNATURE: _ MUST BE SIGNED BY LICENSE GWNER/BUILDER) A FINAL ROOF INSPECTION IS REQUIRED: DATE: 12, THIS SIGNED AND NOTARIZED AFFIDAVIT MUST BE PROVIDED AT THE JOB SITE AT THE TIME OF THE FINAL ROOF INSPECTION, ALONG WITH DIGITAL PHOTOGRAPHS OF EACH PLANE OF THE ROOF SHOWING IN DETAIL ALL COMPONENTS (DECKING, UNDERLAYMENT, FLASHING, DRIP EDGE ATTACHMENT) WITH THE PERMIT NUMBER OR ADDRESS CLEARLY MARKED ON THE DECK FOR EACH INSPECTION. THE PHOTOGRAPHS MUST INCLUDE A RULER OR MEASURING DEVICE TO CONFIRM ALL NAIL SPACING AND OVERLAPS, INCLUDING DRIP EDGE AND VALLEY FLASHING. PLEASE REFER TO THE RE -ROOF POLICY AND INSPECTION PROCEDURE PAPERWORK FOR FURTHER EXPLANATION OF ALL REQUIREMENTS. FAILURE TO FOLLOW ALL REQUIREMENTS WILL RESULT IN A FAILED INSPECTION, A RE -INSPECTION FEE AS WELL AS REQUIRING A DESIGN PROFESSIONAL (ARCHITECT OR ENGINEER) TO CERTIFY, BASED ON PERSONAL INSPECTION, THE INSTALLATION OF ALL ROOFING COMPONENTS. STATE OF FLORIDA COUNTY OF Sanlvla& Sworn to and SupNribed before me this y day of j2e4Ce M62t' 20 4 by: Who is er onally Known to me or has Produced (type of m ification. YP CARA 2a",- mission # GG2080"" Com 0, re EzpilesApni16.? 70+9 c ar ik0.385a{ ocr dllyuTroy. of Notary Public