Loading...
HomeMy WebLinkAbout2610 Narcissus Ave - BR18-004247 - RETAINING WALLOCT 15 2018 PERMIT APPLICATION Application No: S LI / L1 .7 Documented Construction Value: $ :Z . q 7 S Job Address: 7-(-(0 .Sg 2C i 55 y S Avt Historic District: Yes No[3 Parcel ID: Residential Commercial Type of Work: New Addition Alteration Repair Demo Change of Use Move Description of Work: RE: , A I -J (j,) G WA l,t_ vies i PR0 Pcfz.,-'f u N c Plan Review Contact Person: ;,A n 7-r P&TTc 25orO Phone: 32-1- 2_g+9 - G 5-8 1 Fax: q 0 7 & 5_0 ?-&?` Email: (I ve55 h0n,"e— 6u 4e vs @aMc..j - C0-t Property Owner Information Name u-c- Phone: cl0 7 (.! 0 5-,gi 7 Street:.-4 q 75 P- 0 AP-i c i2-urJ Resident of property?: PJ O City, State Zip: sA r 3.Fo{Z 0 ..F(- 3Z77/ Contractor Information Name C-` I A 2e SS . +-i c)"C 5 Phone: `(0 7 c 7 Street: y q 2-5 Fzc 0 60-1C t/- Q_V J Fax: '10 *7 (v 5"0 2_9 7 City, State Zip: SA rJ 0 1? -O C- ' 2_ 7 7 1 Name: Street: City, St, Zip: Bonding Company: Address: State License No.: C Architect/Engineer Information Phone: Fax: E- mail: Mortgage Lender: Address: WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for electrical work, plumbing, signs, wells, pools, furnaces, boilers, heaters, tanks, and air conditioners, etc. r r 1 FBC 105.3 Shall be inscribed with the date of application and the code in effect as of that date: 6' Edition (2017) Florida Building Code NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. The City of Sanford requires payment of a plan review fee at the time of permit submittal. A copy of the executed contract is required in order to calculate a plan review charge and will be considered the estimated construction value of the job at the time of submittal. The actual construction value will be figured based on the current ICC Valuation Table in effect at the time the permit is issued, in accordance with local ordinance. Should calculated charges figured off the executed contract exceed the actual construction value, credit will be applied to your permit fees when the permit is issued. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Signature of Owner/Agent Date Si N . pnPrintOwner/Agent's Name SIP. coo, 4` Signature of Notary -State of Florida Date n o na 3 cNQ Owner/Agent is Personally Known to Me or N Doti Produced ID Type of ID O TOO BELOW IS FOR ofContractor/Agent Date itractor/Agent's Name _ q - ate`:,.. o,.u jV P ANNETTE BLAt: Notary Public • State N, ac Commission # GG ct nt 4 FOP' EAIly Known to Me e e W l 2 USE ONLY Permits Required: Building Electrical Mechanical Plumbing Gas Roof Construction Occupancy Use: Total Sq Ft of Bldg: Min. Occupancy Load: New Construction: Electric - # of Amps Fire Sprinkler Permit: Yes No # of Heads APPROVALS: ZONING: UTILITIES: ENGINEERING: I.ytcC- i6 -'5 "lg FIRE: COMMENTS: Flood Zone: of Stories: Plumbing - # of Fixtures Fire Alarm Permit: Yes []No WASTE WATER: BUILDING: 47F /co -fC- REQUMED )INSPECTU Bpff- A,4,q. ii Mnn I. Max I fusnection Descrintibim. Footer / S6 Stemwall 1, Foundation / Form Board -'Survey Slab /*MonoSlab. Pre our ZO Lintel / Ti6 Beam / Fill Down Cell Sheathing W- alls- Sheathing Roof Roof Dry I Frame - Insulation Rough In Firewall Screw Pattern Drywall / Sheetrocic Lath Inspec,tion Final Solar Final Roof Final Stucc6. /,Siding insulation Final Final Utility Building - Final Door I Final. Window Final ScreenRoom Final. Pool Screen Enclosure. Mobile Home Building Final Pre -Demo Final Demo Final Single Vwnil'y Reddencem Final. Building (Other) DN-SEQUENCE.. Address: E!M-T _0 Mn Max Inspelction Descri2flon Electric. Underground Footei /' Slab Steel Bond Electric Rough T.U.G. Pre -Power Final Electric Final jmpe flon Descri2flolm Plumbing -Underground Plumbing Sewer Plumbing Tub Set Plumbing Final mu Max Inspedionn D'escrkfion Mechanical Rough Mechanical. Final Gas Underground Gas Rough Gas. Final RIEVISED., Yune 2014 i Revisidn Response to Comments o Permit # /v r 3 C Project Address SEP 13 2018 City of Sanford Building & Fire Prevention Division Ph: 407.688.5150 Fax: 407.688.5152 Email: building@sanfordfl.gov Submittal Date i rc SS S le Contact: Ph: ' S Fax: Email: L Y 2Z55 o r . cs? Trades encompassed in revision: E Building Plumbing Electrical Mechanical Life Safety Waste Water General description of revision: 1 t A4 w C' ROUTING INFORMATION Department Approvals Utilities Waste Water Planning Engineering Fire Prevention Building Retaining wall Bottom of Ditch 12.6 Existing Top of Ditch 15.8 1-4 course retaining wall 2.42 Top of retaining wall 17.82 5' run to house at 4:1 slope 1.25 Proposed grade at house 19.07 Mono slab 0.67 Proposed FFE 19.74 5' run at 4:1 HE of 19.74 Top of retaining wall 17.82 _ _, Mono slab 8" I 1-4 course retaining all t Top of ditch 15.8' Bottom of ditch 12.6' // I Grade at house 19.07 1 Fnd. %" Rebar vNoIdentification) PRESERVE AT LAKE tiV MONROE UNIT 2 Plat Book 66 Pages 10 & 11 PRESERVE AT LAKE MONROE UNIT 2 Plat Book 66 Pages 10 & 11 I I I I I I I o I C:) LO ylC N N mI UJ a O C:) Z O I^66 O o m o I Z I I Storm Structure 24" C.M.P. Invert 12.20" 1 WPP OHE Point inBeginning Fnd. 4" X 4" C.M. No Identification) , SW Corner of BM Lot 11 #2 rCORD COPY East 80.00' (D) S 89*38'10" E 79.94' (M) Adjacent Residence FFE=15.63' -i Building Line rarceilaenuncauun 22-19-30-5AD-0000-011 J N. 70' of S. 195' of W. 170' & S. 15' of N. 495'of E. 160' LOT 11 LOT 1177 I o S. 125' Of W. 80',z- ParcelID# cli 19-30-5AD-0000-01 1A c g.p` Proposed 7)Q ^ Patio 24 9' Proposed,••. •.. Proposed. Septic & Drainfield Area One Elevation =19.07. Story •. ••.•, Concrete Block • ' • 1 s' i r8' Q Residence # 2610 Proposed FFE = 19.74' 4 osed Roofed 5.0''.'.'.'.'.'.'.'.;1' 6• I I Pavers Entry 16.0' 3' 15.2'. •' I I Proposed I i 24'9PaversI ' P. iVn opV _O I; IiJDnveway[ OHE= OH-III II 186-' L-1 JI IIi L Fnd M. Rebar Cap Illegible N Sri CD C? to N I M O O J •.• O C:)i''.'.'.'.'.. 0 Cn 2. 0'' m .... Adjacent Residence 1. m •''••' FFE=17.66' N NOTES: I. ALL CONC. TO BE 3000 PS/ Footings have been designed for a 2. ALL STEEL TO BE GRADE 40 soil bearing pressure of 2000 PSF w13r' CO.VER & 25" OVERLAPS Mortar for use in masonry construction shall be either Type M or W E with a fm of 1500- psi in accordance with ASTM C 270 and shall meet the proportion specificationsofTableR607.1 or the property specifications of ASTM C 270. S General. Masonry construction shall be designed and constructed in accordancewiththeprovisionsofthissection, TMS 403 or in accordance with the provisions of TMS 402/ACI 530/ASCE 5. IF A DOWEL IS MISSED, APPLY W/ EPDXY SIMPSON # ET) W/6" EMBEDMENT. DRILL 3/4" DIAMETER HOLES FOR #5 DOWELS. 6I Parcel Identification # 22- 19-30-5AD-0000-011 H S. 125' of Lot 11 LL ( Less W. 80' and E. 160' of Lot 11) a 0. 5'WFnd. M." Rebar Cap " LB 6300" WPP 4' Wood Fence Fnd. %z" it ebarFnd. 1 1/4" IP E L-2 (No Identr..cation) (No Identification) i L-3 Edge of Pavement e6 N Sec.2 Sec.20 b 99' Road Sec. 27 Sec.26 Asphalt ) Range 30 E. Township 19 S. a.(& 1'0 Narcissus Avenue Florida Department of Transportation Fnd. Nail & Plate Variable Width Right -of -Way) REVIEWED FOR CODE COMPLIANCE PLANS EXAMINER DATE SANFORD BUILDING DIVISION A PERMIT ISSUED SHALL BE CONSTRUED TO BE A LICENSETOPROCEEDWITHTHEWr)AK ANi, NOT AS AU rHORITYTO VIOLATE, CANCF •yr rEG A: SET ASIDE ANY OF THE oROV!SIONS ut .} H} rr-C"!,41CAL CODES, NOR SHALL ;SSUANCE OF " ,vw 'REVENT THE BUILDING OFFICIAL FROvw f HEREAFTER REQUIRING CONSTRUCTIONOR VIOLATIONS OF HIS CODE ASSUMED BEARINGS Graphic Sca!e 0' 15' 30, 60' Scale: i"=30' wtLD/ Arc FOOTING STSP DOWN NOTE: THIS STRUCTURE HAS BEEN DESIGNED TO MEET OR EXCEED THE WIND LOAD FpgR( M REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE RESIDENTIAL SIXTH EDITION SECTION R301 DESIGN CRITERIA AND ASCE 7- 10 1. WIND SPEED = 139 MPH ULTIMATE WIND SPEED (VULT) AND 108 MPH (VASD) 2. RISK CATEGORY 2 3. CONSTRUCTION TYPE = SINGLE FAMILY RESIDENCE (V) L474. WIND EXPOSURE = CATEGORY C 2- 4 tf Ml11f Z of 1 T. S. C11ehai Licensed Profe5si'ona! Engineer 531 S. State Road 434 Suite 1001 Altamowe. Springs, FL 32714 407) 521-i557 Fax( 407)521-5434 P. E.0040748