Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
121 Towne Center Cir 09-1347 plans (a)
SEMINOLE TOWNE CENTER - SPACE #F06A SANFORD, FLORIDA REGULATORY A(5ENGIES AA - ALUMINUM A_%OGIATION AAMA - AMERICAN ARCHITECTURAL MANUFACTURER5 A55XIATION AGI - AMERICAN CONCRETE INSTITUTE ADC, - AIR DIFFUSER GOUNGIL AGA - AMERICAN 6A5 ASSOCIATION AIEF - AMERICAN INSTITUTE OF ELECTRICAL ENGINEERS AISG - AMERICAN INSTITUTE OF STEEL GONSTRUGTION A151 - AMERICAN IRON AND STEEL INSTITUTE AMGA - AIR MCVIN6 AND CONDITIONING ASSOCIATION AN51 - AMERIGAN NATIONAL STANDARDS INSTITUTE APA - AMERICAN PLYWOOD ASSOCIATION ARI - AIR GONDITIONING 4 REFRIGERATION INSTITUTE A5HRAE - AMERICAN 50CIETY OF HEATING, REFRIGERATING t AIR CONDITIONING ENGINEERS A5ME - AMERICAN 50GIETY OF MECHANICAL EN6INEER5 A5TM - AMERIGAN 50GIETY FOR TESTING AND MATERIALS AHI ARCHITECTURAL WOODWORK INSTITUTE AWA - AMERICAN WOOD PRESERVERS A55OGIATION AH5 - AMERICAN WELDING SOCIETY BIA - BRICK INSTITUTE OF AMERICA CR51 - CONCRETE REINFORCING STEEL INSTITUTE ETL - ELECTRICAL TE-5TING LABORATORIES F6MZ - FLAT 6LA55 MARKETING ASSOCIATION F5 FEDERAL SPECIFICATION IE5 - ILLUMINATING ENGINEERING SOCIETY MIA - MARBLE INSTITUTE OF AMERIGA NAAMM - NATIONAL A%OGIATION OF ARGHITEGTURAL METAL MANUFACTURERS N55 - NATIONAL BUREAU OF STANDARDS NGMA - NATIONAL CONCRETE MASONRY INSTITUTE NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NSF - NATIONAL SANITATION FOUNDATION NTMA - NATIONAL TERRAZZO d M05AIG ASSOCIATION PGA - PORTLAND GEMENT A55XIATION P5 - PRODUCT STANDARD, U5. DEPT. OF COMMERCE SIGMA - SEALED INSULATING GLASS MANUFACTURERS A550GIATION SMAGNA - SHEET METAL 4 AIR CONDITIONING GONTRAGTORS NATIONAL ASSOCIATION 55PG - STEEL STRICTURES PAINTING COUNCIL TGA - TILE GOUNGIL OF AMERICA UL - UNDERMITER5 LABORATORIES, ING. WGLIB - WEST COAST LUMBER INSPECTION BUREAU WWPA - WESTERN WOOD PRODUCTS A550CIATION SPIE - SOUTHERN PINE INSPECTION BUREAU 5YMB0L LEGEND II4 TITLE A.F.F CEILINGACCESSORIES 5CALE: type TA6 Gr__ TAG finish NORTH! A ( DOOR DETAIL TITLEELEVATION TAG NUM$ER D ? NUMBER KEYNOTE � DETAIL T�O TAG SCALE, 5 -T=D? SHEET REFERENCE Er- ROOM SHEET R�RENGE NEER Sales D NUMBER 13 ELEVATION L� XXXS.F. DETAIL OR SECTION NUMBERMATERIAL CHANGE NUMBER? GT VGT DESIGNATION ? SHEET REFERENCE ? 5HEE REFERff4CE NUMBER EQUIPMENT TYPE NUMBER NEW GOLUMN DE516NATION �-DESIGNATION � MILLWORK / CASEWORK MATCH LINE ? - TAG NUMBER UNM FLAG NOTE - - UNIT2 EXISTING GOLUMN [�� OE516NATION ? SHEET REFERENCE DE516NATION NUMBER ? - �OE516 MARK DESIGNATION PARTITION TYPE ENLARGED PLAN DESIGNATION FINISH TYPE NUMBER? -TAG* DE516NATION ? SHEET RIE'ERIENGEI BULLETIN INSERTION POINT NUMBER -J - TAG PE516NATION ADDENDUM LEVEL LINE, CONTROL POINT OR DATUM BUILDING SECTION TAG FIN. FLR NUMBER? -EL = 0'-0' 5URFAGE MTD. SHEET REFERENCE ? BUBBLESTANDARD NUMBER MIRROR ED STANDARD j�W---TENANT - � �-� O��rf Gi•cGr� �' V' ��0¢oG St. IGcIs`Tt.,C,is 1462c? VE A APPROVED � � (} �;ST � � 1 (ti �O E I� fi _ - y QUIRED Ell y' Date ' ! AItJLf� DS RL�'1cW OF CONTRACT DOCUMENTS IS FOR DES) INTFd T AND CRITERIA COMPLIANCE OtJLY ...' � RESPONSIBILITY SCHEDULE OF MATERIALS AID OR SERVICES BY BY S z z CLARIFICATION � � a BY PROJECT DIRECTORY TENANT: COORDINATOR..,-,;:.. HtM HENNES I MAURITZ 51" PROPERTY GROUP, LNG. 47 WEST 34T14 5TREET 3RD FLOOR NATIONAL GIN CENTER NEW YORK, NY. 10001 115 WEST WA5HIN6TON STREET GONTAGT: JIM HENNESSEY �- INDIANAPOLIS, IN 4b204 PHONE: (212) 564- q22 CONTACT: DAVID FLETCHER : ' i PHONE: (317} 263-2287 FAX: (317) 685-7222 '('�N}��T'S ARCHITECT: .... KENNETH NISCH, AIA RST ILD 5 ICN GON��NT.. 261110 INKSTER ROAD u C1 �, - ' SUITE 200 JCA, INC."' 261110 1NKSTER ROAD SOUTTlF1ELD, MICHIGAN 48034 SUITE 200 PHONE: (248) 355-08610 FAX: (248) 355-08615 SOUTHFIELD, MI.48034 _ CONTACT: ARVIN 5T15PHEN50N PHONE: (248} 355-OSQO j • M.E.F. ENGINEER: FAX: (248) 355-08615 THOR50N BAKER I ASSOCIATES, ING. 3030 WEST 5TREET560ROR ROAD LANDLORD: RICHFIELD, OH 44286 51MON PROPERTY GROUP, INC. CONTACT: AREK TOR051AN NATIONAL GITY CENTER PHONE: (330) 6561-6688 115 WEST WASHINGTON 5REE I FAX: (330) 65q-6675 INDIANAPOLIS, IN 46204 PHONE: (317} 63b -1b00 FAX: (317) 685-7222 ALL PATCH PANELS AND WIRE MANAGEMENT d • ■ 29114 Inkster Road , Suite 200 Southfield; MI 48034 USA 248 355 0890 248 355 089 5 Fax Copyright 2009 KEN NISCH, AIA ATI rights reserved CONTINUITY TEST REPORT FIN15HED TO OWNER • ■ FRE -CONSTRUCTION ALL EQUIPMENT ON TENANT R15ER j#t I • ■ 11 WIRING AND CONDUIT ♦ ■ SEE N67E #8 L16HT FIXTURES - SALES AND DISPLAY FI • ■ ,SEE NOTES. AND #5 LIGHT FIXTURES - BACK OF HOUSE :, ♦ ■ SEE N&E #2 TEMPORARY UTILITIES • i ■ URNAIL.5-5EE SEG 41612 PROVIDE AND INSTALL BARRICADE AT STOREFRONT • ■ PER LANDLORD SPECIFICATIONS REMOVE )=X15TIN6 BARRICADE AT STOREFRONT • ! IF NOT EXISTING Pi=tZ L L. SPEC. 5AWGUTTING, GORING CHANNELING OF EXISTING CONCRETE • ■ RETAIL STORES, DEMOLITION WORK IN LEASED AREA e ! FOR EXCEPTIONS SEE DRAWINGS SOILS REPORT ■ M t,' R C I PER 500 0GGUPANT5 I PER 750 CONCRETE FLOOR SLAB O ■ EXISTING CEMENT TILE FLOORING AT 5ALE5, D15PLAY, AND FITTING ROOMS AREA • ® SEE NOTE #7 PREPARATION OF FLOOR SLAB FOR NEW FINISHES • ■TENANT'S SINK CONTROL AND EXPAN51 N 0 JOINTS1N GE 1 IL NG WALLS A • NO FLOORS ■ I PER 500 = 1 MALE WATER CLOSET NEUTRAL PIERS • ■ IF NOT EXISTING RATED DEMISING PARTITION GYPSUM BOARD • ■ 5¢ NOTE #4 RATED DEMISING PARTITION STUDS •■ SEE NOTE #4 Certification: PARTITIONS WITHIN LEA5ED 5PAGE • ■ METAL STRAPPING, BLOCKING, AND LEDGERS • ■ AGOU5TIG AND THERMAL IN5ULATION, 5AFB • ■ WALL FIN5HE5 INCLUDING BUT NOT LIMITED TO, PAINT AND WALL COVERING • ■ RECESSED AND WALL MOUNTED 5TANDAR05PANELS AND HARDWARE • ■ SEE NOTE #5 $AGK OF HOUSE MILLWORK SHOP DRAWINGS • ■ KITCHENETTE, ADMIN. OFF. t DECO 5TAINLh5 5TTEL CORNER GUARDS • ■ PREFIN15HED MDF BASE • ■ p p /� I- ROJECT GODS ANALYSIS VINYL BASE $AGK OF HOUSE • ■ HOLLOW METAL FRAME5 AND DOOR HARDWARE • ■ MOTORIZED GOILIN6 GRILL)_ 5 AT STOREFRONT ENTRANCE 5 • ■ I. PROJECT NAME:. HSM 2. PRO.1EGT ADDRE55:. . . . . . . . . SEMINOLE TOl^INE CENTER, 200 TOWNIE CENTER CIRCLE, SANFORD, FL., SPACE #F06A 3 PROJECT DESCRIPTION: RETAIL STORE 4. APPLICABLE CODES: . . . . . . . . . . . ... .ALL WORK SHALL CONFORM TO ALL APPLICABLE GOVERNING CODES PER THE SANFORD, FLORIDA, BUILDING DEPARTMENT INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: -F10RIDA BUILDING GORE (20o t} -FLORIDA MECHANICAL CODE (2007) -FLORIDA PLUMBING GODE (20CF0 -AMERICANS WITH DISABILITIES ACT OF 161610 5. BUILDING DATA A. OCCUPANCY. MALL TENANT LEASE SPACE $. USE GROUP . . . . . . . . . . . . GROUP "M" G. GONSTRUGTION GLA551FICATION TYPE "2-B" D. COVERED MALL . . . . . . . . . . . . .YES EXISTING E. 5PRINKLERED . . . . . . . . . . . . . . YE5 PER NFPA - 13 F. GROSS FLOOR AREA . . . . . . . . . . 20,688 5.F. TOTAL b. OCC UPANGEY CALCULATIONS: ROOM NAME 5_F. FACTOR LOAD SALES AREA 18,6613 II30 b24 ELECTRICAL ROOM 117 1/300 ADMIN. OFFICE 127 I/100 2 MANA6ERS OFFICE 143 I/100 2 LOUNGE 15b IJI5 11 STOCKROOM 585 11300 2 MEMS TOILET ROOM 127 1/100 2 WOMENS TOILET RM. 13b 1/100 2 JANITOR'S GL05ET 45 11300 1 DECO ROOM 4 1/100 2 16 1 ROOM 16 1/00 1 B.O.H. GORRI DORS 356 - - TOTAL 20,b&5 b50 FITTING ROOM DOORS, FRAMES AND HARDWARE • ■ SEE NOTE #5 FITTING ROOM COMPARTMENT ACCESSORIES • ■ SEE NOTE #5 STOREFRONT FRAMING ENTRANCE PIERS AND GLAZING • ■ ACOUSTIC TILE G1=1L1NG 5Y51T=M • ■ GYP. BOARD GEILIN65, GYP. BOARD SOFFITS AND SUPPORT FRAMING *I ■ FfBER6LA% AGGENT PANELS t DOORS IN CEILINGS AND PARTITIONS 01 ■ 1Consultants: RETAIL DESIGN CONSULTANT - JGA INC 291]0 Inkster Road Suite 200 Southfield, kll 48034 USA 248 355 0890 248 355 0895 Fax °opj1�°+` °+. °..www.)ga.com JGA �f j #: 1-209"057 MIRRORS - 5ALE-5 FLOOR • ■ SFS NOTE #5 LIGHTED MIRRORS FITTING ROOM COMPARTMENTS • ■ 5)=E NQT -5 #5 AND #16 GASHWRAP AND FREE STANDING FLOOR FIXTURES• ■ SEE NOTE #5 COUNTERS GABINETS SHELVING AND MISC. CA5EWORK AT BACK OF HOUSE • ■ ` COAT RACK AT BACK OF HOUSE • ■ REFRIGERATOR AND MICROWAVE AT LOUNGE • ■ SEE NOTE#12 BOTTLED WATER DISPENSER AT LOUNGE • ■ SEE NOTE #5 TOILETROOM AGGE550RIE5 O • ■ SEE NOTE #5 FLOOR SAFE AT OFRGESEE NOTE #t5 FIRE-SAFING AND FIRE -PROOFING • ■ SEE NOTE #II • ■ MILCHAWAL FLOOR, ROOF PENETRATIONS AND PATCHING • ■ WAG DUCTWORK AND SUPPORTING FRAMING • ■ WAG AND AIR HANDLING UNIT(5) e ! SMOKE EVACUATION 5Y5TEM o ■ HVAC DIFFUSERS AND GRILLC-5 • ■ SMOKE DETECTORS • ■ DAMPERS • ■ EXHAUST FANS' • ■ CONTROLS AND CONNECTIONS (`,. • ■ OUTSIDE AIR INTAKE • ■ TESTING AND BALANGIN6 • rLECTRInTLAN. �• e ELECTRICAL SERVICE TO PREMISES , • ■ GONDUIT FOR COPPER FEED FROM LLS 5WITGH6EAR TO TENANT E.EG. ROOM 10 ■ 4 COPPER FEED FROM ILLS 5WITGH6FAR TO TENANTS ELECTRICAL. ROOM • ■ l FU5IBLE 015GONNECT AND LANDLORD'S 5WITG! kI - IR 101 Vol LAN CABINET • ■ ALL PATCH PANELS AND WIRE MANAGEMENT d • ■ CONSECUTIVELY LABELED' :;' • ■ CONTINUITY TEST REPORT FIN15HED TO OWNER • ■ METER J' • ■ IF NOT EXI5TWF ALL EQUIPMENT ON TENANT R15ER j#t I • ■ 11 WIRING AND CONDUIT ♦ ■ SEE N67E #8 L16HT FIXTURES - SALES AND DISPLAY FI • ■ ,SEE NOTES. AND #5 LIGHT FIXTURES - BACK OF HOUSE :, ♦ ■ SEE N&E #2 EMERGENCY LIGHTS AND 51DE LIT EXIT $ I6N5 ' • ■ SEE N&E #2 LAMP5 ON SALES FLOOR ( • ■ SEE NO #2 . LAMP5 AND INSTALL ON TRACK FIXTURES • ■ t, 1I INSTALL ATI 4" D.G. C\' SIGNAGE AT MALL STOREFRONT ANDlOR EXTERI f-4@ ■ k5EEE NOTES #., AND #5 ABBRE Y I AT I ON5 CONDUIT W/ PULL5TRING FROM LL'S PHONE GL O TENAMPLEG. ROOM • ■ 25 PAIR CAT25 GABLE FROM LLS PHONE GL 0515T TO T a . ROOM ♦ 1 SEE NOTE #q 51EN5ORMATIG SECURITY SYSTEM {JI SEE NOTES #110V #5 ADJ. - ADJUSTABLE MEGH. - MECHANICAL DATA AND TELEPHONE SERVICE TO PREMISES • ■ AFF. - ABOVE FIN15HED FLOOR MED. - MEDIUM DATA AND TELEPHONE EQUIPh1ENT i PLUMBING FI REQUIREMENTS: CLAS5IFIGAT�ON MERGANTII E, TABLE 403.1 W/5EG.4032 AND 4033 GLA%lFIGAT N OGGUPANGY OE5GRIPTION WATER GLOSET5 LAVATORIES DRINKING OTHER URNAIL.5-5EE SEG 41612 FOUNTAIN SEG 410.1 MALE FEMALE MALE FEMALE O RETAIL STORES, T.YP USE M SERVIGESTATIONS, SHOPS 5ALESROOMS, MARKETS I PER 500 0GGUPANT5 I PER 750 I PER 1000 SERVICE AND SHOPPING GUTTERS SINK PLUMBIN6 FIXTURE INDICATED AND PROVIDED: I PER 500 = 1 MALE WATER CLOSET I PER 750 = I MALE LAVATORY 2 PER 500 = 1 FEMALE WATER CLOSET I PER 750 = I FEMALE LAVATORY I PER 500 = 1 MALE URINAL I PER 1000 = I DRINKING FOUNTAIN I REQUIRED SERVICE 51NK ALT. - ALTERNATE MFR. - MANUFACTURER @ ■�, NO #I BELL AT EMPLOYEE ENTRANCE • ■ NOTE' I ALUM. - ALUMINUM MIN. - MINIMUM 1. REQUIRED EXITS: . . . . . . . . . . . TWO (2) EXITS REQUIRED, TWO (2) PROVIDED ANOO. - ANODIZED M. - MIRROR AUDIOVISUAL 5Y5TEM COMPONENTS r • ® `SEE TE5 #1 #5 20,688 S.F. l 30 OCG. LOAD - 6q0 OCG. LOAD AUTO. -AUTOMATIC M15G. - MISCELLANEOUS SPEAKERS t t • ■ SEE N61T5 #I Aw #5 bqO x.2 = 138 LIN. IN. / 12 = 115 LIN, FT. APPROX. -APPROXIMATE MLD'6. - MOLDING SPEAKER WIRING 1 • Mi OTE 44 EXIT WIDTH REQUIRED: 115 LIN. FT. B/D - BY OWNER MTD. - MOUNTED LUMBING s q EXIT WIDTH PROVIDED: (1) - 11!-13/4' GRILLE W. - BARD MTL. = METAL SANITARY WASTE DOMESTIC�PRISE.G. TO SUPPLY IFT EXISTING (!) - 3'49" SINGLE DOOR BLK. - BLOCK NO. - NUMBER WATER METER (SITE WATER METER) ! ! • ■ BLK'G. -BLOCKING NOM. -NOMINAL WATER METER PREMISE 5UB-METE --bi S. EXIT ILLUMINATION: . . . . , . . . .EMERGENCY EXIT ILLUMINATION SHALL BE PROVIDED A5 SHOWN ON DRAWINGS. BOT. - BOTTOM NON-GOM - NON-GOMBU5TiBLE SANITARY WASTE, DOMESTIC SUPPLY,'AND VENT PIPES WI IN PREMISES • ■ q. EXIT REQUIR-IENT6: . . . . . . . . . . .MIN. � WIDTH 15 36° GL6. - CEILING N.T.S. NOT TO SCALE PLAS. LAM. - PLPL ASTIC LAMINATE NOTE #10 FIXTURES AND EQUIPMENT COL. -COLUMN • ■ MIN. NiMBER OF EXITS REQUIRED 15 2 FOR OCCUPANT LOADS 50 OR MORE. GOR. - CLEAR O.G. - CENTER FLOOR DRAINS AND WATERPROIOF MEM$RANE • ■ Q GONST• - CONSTRUCTION PTD. - PAINTED GAS PIPING _ • ■ CONT. - CONTINUOUS RAD. - RADIUS _ U GONTR. - CONTRACTOR REF. - REFERENCE SPRINKLER MAIN TO PREMISES 11 ® ■ SEE NOTE #13 # DET. -DETAIL REM. - REMOVE SPRINKLER 5RANGHE5 DROPS AND HEADS SEE NOTE510b AND #15V OIA6. - DIA60NAL REOV. fuREQUIRED FIRE ALARM SYSTEM 4 • ■ SEE NOTE #5 D - DIAMETER RET. - RETURN IRE EXTINQU15HER5 DIM.im. DIMENSION REV. -REVISION COORDINATE LOCATIONS W/ FIRE MARSHALL J HSM REP • ■ Z a$ 5 OKI= OETEGTORS • ■ tu ON. - DOWN SECT. - 5EGTION POST CONSTRUCTION DWG. - DRAWING S.F. - SQUARE FOOT U W N EA. - EACH 5 _SHEET FINAL GLEAN UP AND MAKE READY FOR OGGUPANGY t • ■ ELECT. ELECTRIGAL 51M. 51MILAR GERTiFIGATE OF OGCUPANGY A • ■ Lit Qr EQ. -EQUAL- SPEC. - SPECIFICATION NOTE #I ELECTRICAL SERVICE AND CONNECTIONS BY GENERAL GONTRAGTOR. Z EQUIP. - EQUIPMENT 50. - 5QIUARENOTE #2 GENERAL GONTRAGTOR TO PURCHASE SGHEDULED`FIX URE5 FROM TENANT'S VENOOfe LAI � I 3 FXI5T'6. - EXISTING STD. -STANDARD NOTE #3 SEE ACCESSORY SCHEDULE ON DRAWINGS. + DRA `4I N6 INDEX Q � Q �- �-- U, EXT. - EXTERIOR SVM. -SYMMETRICAL NOTE #4 FLOOR PLAN AND PARTITION -SCH15DUL!` FOR ADDITIONAL MATERIALS TO BE ADDED TO FJCISTING DEMISE PARTITIONS. ZZ � w F. R• -FLOOR TEMP - SYSTEM NOTE #5 195TALLATION TO INCLUDE UNL.OADIN6 UNPAGKIN6 ASSEMBLY A5 REQUIRED AND GEMENT A5 OIREGTED BY TENANT. W O F.RP. -FIBERGLASS REINFORCED PLASTIC TEMP.-1I=MPORARY NOTE#{� 1N UDiN6 MODIFICATION OF ANY ' 15TIN6 HEAD LOG` TIONS -ALL SPRINKLER TO BE CONGEALED. ��ITWTLRAL IGAL o tu V � Q F.R.T. -FIRE RETARDANT TREATED TVP. -TYPICAL A -0.I COVER SHEET EO.I ELECTRICAL LEGENDS AND SCHEDULE :r (� Z FURR'G. -FURRING U.D.N. - WLE55 OTHERN15E NOTED NOTE #7 INSTALLATION TO INCLUDE RECEIVING STORING AND AGK1N6. A-02 DECOR FINISH SPECIFICATIONS ODOR 5GHI=DULE E02 PANEL SCHEDULES o 3 Q HD. - HEAVY DUTY VERT. - VERTICAL NOTE #8 1N5TALLIN6 BUT NOT LIMITED TO P05 DATA POWER AND, NES. D -IPI DEMOLITION FLOOR PLAN 150.3 ONE LINE -�Z-- O HOW - HARDWARE V.I.F. - VERIFY IN FIELD NOTE #q 6.G. SHALL PUNGHDOWN TERMINATE EACH END OF GA15 C'. BOTH 66 BL K5 IN LLS CLOSET AND TENANT'S ELECTRICAL ROOM. O _l HORZ. - HORIZONTAL F-1.1 EGRE55 AND FIXTURE FLOOR PLAN E2.1 GENERAL LI6HTIN6 PLAN U }" LL- Q W/ -WITH NOTE #IO WATERPROOF MEMBRANE WILL BE INSTALLED IN TOILET 5 LOUNGE. N. 4" WRAP DN WALLS. .■ F-12 WALL STANDARDS FLOOR PLAN F)2 TRAGK/GOVE LIGHTING PLAN pp Z HR. -HOUR 114%O -WITHOUT NOTE #II 6.G. TD PI20VID1= ALLOWANCE iH BID. F-13 FIXTURE LIGHTING FLOOR PLAN E3.! POWER PLAN a O Q N CR 0 HT. - HEIGHT 11 - AND NOTE #12 G.G. TO INCLUDE WATER LINE INSTALLATION TO REFRIGERATOR- F-1.4 ENLAR6W FIXTURE LIGHTING FLOOR PLANS E32 AUDIO PLAN t L.P. -LIGHT PANEL � - AT NOTE #13 LANDLORD tD LEAVE HEADS TURNED DOWN. SPRINKLER SYS WILL REMAIN CHARGED WITH THE HEADS IN THE EX5T LOG. F-15 ENLARGED FIXTURE LIGHTING FLOOR PLANS E3.3 SECURITY PLAN MAX. -MAXIMUM G -CENTER LINE NOTE #14 6.6. TO PROVIDE CONDUIT 4 PULL 5TRN65 FOR 5PKR5. TENANT VNOR TO iN5TL. 5NO. 5Y5TM. VIA MLTPL. 51TE V5T5. 6.G. SHALL A-1.1 ARCHITECTURAL FLOOR PLAN E3.4 HVAC POWER PLAN DRAWINGS ISSUED FOR: COORDINATE WITH TENANTl15NDOR. A-1.2 ARCHITECTURAL FLOOR PLAN DIMENSIONS E35 FIRE ALARM PLAN O programming NOTE #l5 ALL HEADS IN GYP. BD. CEILINGS AND LAY -1N TO 13E FULLY REG155SFJ7 AND GONG15AL131. A-1.3 ENLARGED ARCHITECTURAL FLOOR PLANS E4.1 ELECTRICAL DETAILS A-1.4 ENLARGED ARCHITECTURAL FLOOR PLANS E5.1 ELECTRICAL 5PEGIFIGATION5 0 schematic des: 02.(kl•Oci T �/ p NOTE #16 SALES FLOOR AND;�DIVIDED FITTING ROOM`MIRRORS BY 6.G. AND INSTALLED 8Y 6.G. ❑design dev. A-15 ENLARGED PROJECT KEI" PLAN RP17_ Ir-r,T I nr,`AT1nN PI &N A -I.6 DECOR/FLOOR HIGOVERING PLAN FLOOR PLANS �2 ELECTRICAL SPEGIFIGAT10N5 O bidding • - t-IK5T LEva. PLUMBIN6 FIXTURE REGVIREMENT5: , --- - _- .. ___ - - --- - ___ _._.-.___-._1 _.- _ ....- ----.. -1 - I- -,. FU51BLE P15(_'ONNEG,r AND LAN-OLORP'5 5NTr,H6EAR - 0 I ffl - r,LA551FIGATION I OCr"AZY � I I LAN GABINET 0 -_ 01 PRINKIN65 OTHER I ALL PAT6H PANEL5 AND HIRE t,tANAGEMENT 0 ffi FOUNTAIN GON5EGUTIVELY LABELED 0 E - MALE . I FE CONTINUITY TE5T REPORT FIN15HEP TO OKNER 0 N . I � - .". ,RETA1L,5TORE5, . . R I I lk ff I ft I A I a % a , ' ' 3" E M I A0 D4 L E TOO "' W N � (0 3" Elk E R — S A P A (_ "a" Z ff'"F 0 6A METER ALL EQUIPMENT ON TENANT R15ER DIAGRAM is 0 M IN a IF NOT EX15TIW--2 � ' �. SEWCE5TATIO1�15;9i0%, j 5ALE5ROOM5, IMARJ�ETS ' %,O,, 1") IT . HIRING AND CONDUIT . LIGHT FIXTURE5 - 5ALE5 MO P15PLAY 61 0 1 M - 9 igH 5EE NOTE #8) 5EE NOTE5 #2 AND #5 . I . I ''-l-l",AW,.SHOFFI�&.r,E,NTB",16� 1 1 % 11 R I I 1, I % P% A ' 'IN I LIGHT FIXTURE5 - BACK OF HOU15E 0 J1 I 5EE NOTE 412 . PLIUMB M f LX71RE - INDICATED AW FROVMED. . . I � . - . S' A �, 41 F 0 R I D FLU'RIUA � EMERGENCY LI(5HT5 AND 510E LIT EXIT 5IGN5 - 0 - � 0 ", 5EE NOTE #2 k. . , �_ .,. 1. I , :.� �! -R,-50 = FEEMAL.E.LAVATORY � I I fE � 3 " . LAMP5 ..ON 5ALE5 FLOOR , . . I I OF , m 5EE NOTE 02 � . . . I .-r-- I , . '. t �_ 5ewia_ -5tNK � . . . I . 1 1 1 . � LAMP5 �AWIN5TALL ON. TRACK:FixTuRE5 � - : 0 1 I IN5TALL AT 24' O.G. - : . R55ULATORY A6ENGIE5 I ABBREVIATIORS i I � -, 7 ..510ACE AT MALL'-,5TOREFRONT ANWOR EXTERIOR I __';WNPU1T WIPJLL-5TRJNr7*F-ROM.',LL5,PW�.E,-r,W5ET, TO JERANT ELEG. ROOM � - 91 0 a , M 10 5EE NOTE5 #1 AND #5 .11, I - 25 PAIR C;AT25"(,�A!3t,E'�FROM'LU5'PHONc':'6LO5ET'TOTERANT ELE(,. ROOM - G is I 5EE NOTE #q � 5EN50RMATIG SECURITY 5Y5TEM I* I I 5EE NOTE5 #1 AN19,05 , .,", - AA - ALUMINUM A_%OCIATION ADJ. - ADJ)5TABLE MECH. - ME( ,HANIGAL DATA AND TELEPHONE 5ERVIGE TO PREM15E5 I I in- PLUMBIN6 FIXTURE REGVIREMENT5: , . . I I GLA551FIGATION MERGANTII F, TA13LE.403j4NreC.403.2 AND 4033 . r,LA551FIGATION I OCr"AZY � I I I -. VE5CRIPTIM . . . - k4ATER CL05ET5 I LAVATORIE5 PRINKIN65 OTHER _. - I -_ .��'.URNAII_5-51EE 5EG 41q.2 FOUNTAIN I . : . - t", IMALE-7 FEMALE MALE . I FE ; . - . I � - .". ,RETA1L,5TORE5, . . I TYPE OR LEE - M . - " - � . � ' �. SEWCE5TATIO1�15;9i0%, j 5ALE5ROOM5, IMARJ�ETS ' , T-,'FER 500-OCGUPANT5 I PER 150 1 PER 1000 5ERVIGE I . I . I ''-l-l",AW,.SHOFFI�&.r,E,NTB",16� � , I I I ... .�� I 5INK . PLIUMB M f LX71RE - INDICATED AW FROVMED. . . I � . - . I PER 500 =1 MALE KATER CLOEET' . I I . 1. I I . 4�PER-W�=.,I,`MALE.LAVATORY - 2 PER 500 = I FEMALE NATER CLQEET, . , �_ .,. 1. I , :.� �! -R,-50 = FEEMAL.E.LAVATORY � I I fE � I 1�f_R_%O, = I MAJ,f �WJXAJ, . . I � � � .., , j F,zlz .,p tDRIKIt0-f()WTAN ,Qq�=:, I . I � . . . I .-r-- I , . '. t �_ 5ewia_ -5tNK � . . . I . . I .1, , . � AAMA - AMERICAN ARGHITE( ,TURAL MANUFAGTURER5 A55061ATMI AFF. - ABOVE FINISHED FLOOR MEP. - MEDIUM PATA AND TELEPHONE EGJIPMENT 61 E 5EE NOTE #1 - - . .- - I I . I I ,. � !%� AGI - AMERICAN CON( ,RETE IN5TITUTE ALT, - ALTERNATE MFR. - MANUFA6TURER - . I � � I - BELL AT EMPLOYEE ENTRANGE 4D 0 5EE NOTE #1 ..- , I . �11, � 1, � , , I APG - AIR PIFFU5ER COUNCIL AWN. - ALUMINJM MIN. - MINIMUM - -1. REG?UIRE9. EXIT5 . . . . . . . . � - . �, �. " TAD (2) EXIT5 REQUIRED, TH9- f2) PROVIDEP I :�; t AUPION19JAL 5Y5TEM GOMPONENT5 0 a 5EE NOTE5 #1 AND #5 1 I- I I !� � � . '20f AGA - AMERK ,AN GA5 A550GIATION ANOP, _ A . � � bD5 5.F. 1 30 OCL. LOAD = 6qO OGC. LOAD �,. J�j nw-DIZED M. - MIRROR . � ". � ....'' 1,�': 5PEAKER5 ,q § 5EE NOTE5 #1 AND #5 _,.,,_., �bqo x 2 = ODLIX IN. 1 12 = 115 LIN. FT. I :, it"", AIEE - AMERICAN IN5TITUTE OF ELECTRICAL EN61NEER5 AYTO. - AUT01"LAT16 M156. - M156ELLANEOL6 — --T— ._ - . F , �, :! " A15G - AMERI( ,AN IN5TITUTE OF 5TEEL CON5TRUCTION -7 5PEAKER HIRING � , 0 1 5EE NOTE #14 � . . - EXIT NDTH REGLIlRE9:11.5 LIN. FT. '01, APPROX. - APPROXIMATE MI -06. - MOLDINC - __ .__ - . I � � . I F, JL, 11 , A151 - AMERICAN IRON AND 5TEEL IN5TITUTE B/O - BY ONNER MT9. - MOUNTED _? _771 . . .A, -)E I ,.; LQkQ I N Q, - I . _F_X1TKPTI4.PR0VIL-D:' ffl�11'-q 3/4" GRILLE . . � f : . . .- . I AM6A - AIR MOVING AND CONDITIONING A550GIATION Bu. - BOARD MTL. - METAL 5ANITARY KA5TE, POHE5TIG 5UPPL'(, AND VENT PIPE5 TO PREN15E5 N 6L. TO 5UPPLY IF NOT EX15TIN6 . I � . � (1) -54o' 5IN6LE POOR . � I -1 fl , , ' , � . . ;r� I . � � . - I I I � ,. I �; I AN51 - AMERICAN NATIONAL 5TANPARP5 IN5TITUTE I BLK. - BL ff,-K No. - NUM13ER KATER METER (51TE KATER METER) 0 IN j, � � I I'l . I . �, 1 1 b- EXIT 1WHINATION .. . . . . . . . . . -. * . . '.EMLReENC.Y-,�'EXrT.U!V-11NATIM.5RALL BE PROVIDED A5 SHOHN ON DRANN65. . I � !,�,, APA - AMERICAN PLYHOOP A550GIATION 6 L K'6, � - BLOCKING NOM. � - NOMINAL KATER METER (PREM15E 5B -METER) o a - "i. 1! , � . .. ,1 _: _" . ,;.:I I I ; ARI ,ONI)ITIONINC7 4 REFRIGERATION 11`15TITUTE 'q. EMT: REGO)IRE-MEW5.- . - � . . . " . 'MIW E6RE55 W19M 15 3b* � , � .1 - � "? � . - AIR ( I I BOT. - BOTTOM NON -601-1 - NON-( ,OMBL6TIBLE 5ANITARY AA5TE, POME5TIG 5OPPLY, AN(P VENT PIPE5 118THIN PREM15E5 0 0 1 1 . , "I - - - . � 'M- t MM8 '7"�t%2,~`t0AD`5 50' " E. * � � ! A5HRAE - AMERICAN 50( ,IETY OF HEATING, REFRIGERAT1% I AIR 60�Dff IONIR-5 ER'61NEER5 G L 6. - ( ,EIL)% N.T5. - NOT TO 56ALE FIXTURE5 AND EWIPMENT - ______ �, - �` . I I _-!W10-10 ' ` F �5 W,_ A e V' OR KOR . . �� _!�]___ -_ . � �. �!�' I A5ME -. AMERI(,AN -50(,IETY,OF MEGHAN1CAL EN6INEER!5 j ,(ILR- .- 6LEAR OL. -ON 6ENTER ' ; __ _q . I.. ..., 11111- , �_, � �... I . � . �!._,� I 1, -ERFR 3fWLF I � 11 li � 1; - 11 . . . I ,< �� I � I _: ,' . .FLQOR.,DR;hjN5"AW'14AT , 0 Of � PO4, I )v _11 . � ,� 6EE NOTE #10 I I J615TH -W4ERICAN50GIETY FOR 'TE!5TIN6,XV 1KATERIAL5 .� J�0_ - CoLb"`I ,PLA'5_1�Wi. R_A5T rG,L.WJRATFE . I- _____�� - 1, - , 1 7 . -� . �, - I . , . " I . � �' I . ; , , _�, 4 - AR6HITEGTURAL �AOOPWRK'IN5TITUTE Cla6T. - 60�6TRI)Cflox Im. - PAINTED � V , '. � � . . V AN I 'QA5'-PIP1N& i I � . � - . `�' I AKPA - AMERICAN kVOO PRE5ERVER5 A56COCIATION I Caff. - CONTI�IVU5 RAP. - RAPIU5 FIRE PROTECTION 7=' 1 § I t 16 IN 5EE NOTE #13 :# . If , A�'6 - AMERICAN kELPINC75OCETY U -AM - CONTRALTOR REF. - REFEREW-,E 5PRINKLER MAIN TO PREM15E5 _77 - � - REA41EWED I W_ LU . _', �_�_ ; _ I �. - .� � elz . - 5RI( ,K IN5TITLJTE OF AMERICA M. - VEE7AIL REM. - REMOVE 5PRINKLER 5?_A,N6HE5 PROP5 A�V HEA05 . � I I I '�H NOTE5 09 ANP #15 � I I 131A 140 9 I tll� I I . ,�� I 11 I . - . Lu Q 11� r f I ti , - 1, . I CR51 - CONCRETE REINFORCING 5TEEL IN5TITUTE PIrA6. - DIAGONAL REOV. - REGUIRED FIRE ALARM 5Y5TEM 0, I 5EE NOTE #5 ,01 I- _< � , , , _�'' 0;'! . , ETL - ELECTRICAL TE5TI% LABORATORIE5 B , I 0- : "" 1 PIAM� - DIAMETER REE T, - RETURN V, - � I . , FIRE EXTIN61J15HER5 (GOORPINATE LOGATIONS W FIRE MARC5HALL 4 HVI REP.) 0 Jim :z 0) � - il" j_j - !, � FC7MZ FLAT C2LA55 MARKETINC7 A55061ATION DIM. - PIMEN51ON REV. - REV15ION - I , If, - ; I � I �1, 11 5MOr,E PETEGTOR5 � 0 Im I . Iva LU � - , I : - FEDERAL 5PEGIFIGATION 5EC,T. - 5EGTION &qm, d Re P16V D fl'.�o � i'l F5 PN. -0041 " ,)it(y I I � — _7 , " W CNI POST CONSTUCTION Q �'�:. IE5 - ILLUMINATING ENC71NEERINC750GIETY DW -7. - PRAW6 5.F. - 5WARE FOOT . =7= �:�!, I . � . � �1; I FINAL CLEAN UP ANO MAKE READY FOR O(1,UPANGY 0 "" 7w I 7Ni4n _�11 .. r, '� MIA - MARBLE IN5TITUTE OF AMERICA EA. - EACH 5HT. - 9iEET w qj - W . �!� 1 �9 6, LU - .: V NAAMMI - NATIONAL A550GIATION OF ARCHITECTURAL METAL �-WVFA( ,TI)RER5 ELE(,T� - ELECTRICAL 51M. - 51MILAR CERTIFIC,ATE OF 060)PANCY J-101 .1 - I i! 1-1 � D�,cn� � � - 1. 11 fl, � - W 1z Zy , '"' I I z: , - I J - NE35 - NATIONAL 13UREAU OF 5TANPARP5 IN < I 't - I EO. - EGUAL 5 PE 6. - 5PE(,IFIGATION NOTE #1 ELECTRI( ,AL SERVI( ,E AND 6OHNE( ,TION5 BY 6ENERAL CONTRAK JOR. - � I I x Q M, t � '111 N6MA - NATIONAL CONCRETE MA50NRY IN5TITUTE EGUIP. - EGUIPMENT �0. - 5GUARE NOTE #2 GENERAL 6ONTRAr,TQR TO PURGHA5E -5CHEMLEP FIXTURE5 FROM TENANT5 VENDOR. I H . 1- 01 I ff4 < � I 41 " I i NEMA - NATIONAL ELECTRICAL MANUFA( ,TURER5 A55OGIATION EX15T6. - EX15TIN6 5TO. - 5TANPARD NOTE #3 5EE A66E55ORY 5GHEPULE ON DRAW1675. DRAAIN6 INDEX . . L,L (�, I � . . V- �- , I � �i:," I I - I ;�i .1 NFPA - NATIONAL FIRE PROTECTION A550GIATION EXT. - EXTERIOR 5ym. - 5YMMETRIGAL NOTE #4 5EE 'FLOOR PLAN AND PARTITION 5GHEDULE FOR ADDITIONAL MATERIAL5 TO BE ADDED TO EX15TIN& PEM15E PARTITION5. :z W LU �*.. ix : ,I ".L � ,,, N5F - NATIONAL 5ANITATION FOUNDATION FLR. - FLOOR 15Y5. - 5Y5TEM NOTE #5 IN5TALLATION TO INCLUDE, LJNLOADINC7, UNPACKING, A55EMBLY A5 REQUIRED AND PLACEMENT A5 DIRECTED BY TENANT. . tu Lul �) I , , 1, - . . NTMA - NATIONAL TERRAllO 4 M05A]( , A550GIATION FRP. - FIBERC7LA55 REINFORCED PLA5TI(, TEMP. -TEMPORARY - ARCHITECMNAL . � C Q -A . �, i . � fLMCeTRIr,,AL I U_ < I I. 1 . . RCA - POPjLA40 CEMENT A560,r,IATION FFRT. - FIRE RETARDANT TREATE91 TYR -- TYPICAL .. NOTE #6 INGLU01% MOPIFI( ,ATION OF ANY EX15TIN6 HEAD LO( ,ATION5 - ALL 5PRINKLER HEA95 To BE GON( ,EALEP. I I . . . 1. I � . I 0 _j. =).: I 11.1 " "Awoj WVER�511�T I WJ ELECTRICAL LEGENP5 AND 5GHEDULE = . Lur �, I , . . I p !, 1 P5 - PROMT5TANDARD, U.5. DEPT. OF COMMERCE NOTE #1 IN5TALILATION TO IW,LUDE RE6EIVIN6, 5TORINC7ANP UNPA6KIN6. 0 40L 2 j 1, :;E I � � , (2) � FURR'&� - F U R f -1,11N 67 U.O.K - UNLE55 OTHERN5E NOTED .. I I A-0-2, DELM-FIN15H 5FECIF V,ATIM-,-A'DDGR_50fD1U EO,2 PANEL 5GHEPULE5 101,z:t - .,W r I � I F . , " I 516MA - 5EALEP IN5ULATIN6 6LA55 MANUFA( ,TURER5 A55MLA.TlOi � I I W. - �EAVY PUTY VERT. -,VERTV,,AL ''WTE g, -%TALL I NOBUF � NOTI IM rTFD.--T0'IP05 � ?_%1ER-,WV,:1PHONE5. � -4 I-, _ � .., � - V-1.1 . PEMMffI,ON FLOOR PLAN I E03 ONE LINE 1 (3, . < � 5MAGNA - 5HEET METAL 4 AIR ( ,ONPITIONINC7GONTRACTOR5 MWHAL A56"TION i . I � .0 -J, "A ; - HAR9KAIRE I - VERIFY IN FIELD NOTE #q �OL. 9iALL'MhVO�-N TERMWATE �.EACH. END OP.CAT5 ( ,ABLE5 BOTIk '66 ,BLOCK,51N LL!5'GL05ET AID TENANTS ELEGTRI( ,AL ROOM. � 1: I- . � FC4V_ Vif. — ; . " F -LI F6RE56 AND FIXTW,E-FLOOR PLAN E2.1 GENERAL LIGHTING PLAN - - _LL -< , I z I 1[ t I j ' . ,� , * 10 8 � 55P6 - 5TEEL 5TRUGTURE5 PAINTING GOUNCII ; MoRz. - WWOUTAL W - AITH I NOTE 110 MATERPROOF MEMBMIEF W U1 BE IN5TALLE9 -IN TD[LET,'ROOM5.4 LM6E. MIN.�A" -YIRAP ON KNLL5. 'v'f-1.2 144LL.'5TANDARD5 FLOOR PLAN E2.2 TRAGK/GOVE LIGHTING PLAN .X _�' ... 1 - . I . .. 110TE111 6L. TO,'PRO.140E -,ALL0l-W6-E JW&U. � I . 11 - '. � I f-131' FIXTURE LI&HITIN& FLOOR PLAN I �_ I I I TGA - TILE COUNCIL OF AMERICA W. - HOUR �1/0` - �-IITHOUT Ill ---..- ____ .-,----- -, E3.1 POKER PLAN a_ 0) C4 .0) If , � . I I . I , : UL - UNDERKRITER5 LABORATORIE5, ING. HT� - HEIGHT 4 - AND . "' 'ENLAR6FD FIXTURE L16KIN& FLOOR PLAN5 1_ � . � � : :� I - - NOTE #12 G.C. TO INCLUDE HATER LINE IN5TALLATION TO REFRIC7ERATOR. - . ,.-.F-IA . I E3.2 AUDIO PLAN - , ... � li � f . , I I W11 , I I , 3UREAU L.P. - LIC7HT PANEL @ — - � �. I I IF -15 - ENLAR6E FIXTUREELIC*ff IN& FLOOR FLAN5 E33 5ECURITY PLAN . � , �, ,�_�', . H6LI13 - ],,E5T COA5T LUMBER 11�15PEGTION e - AT -_ .. I I . NOTE #13 LANDLORD To LEAVE HEAD5 TURNED DOM. 5PRINKLER 5Y5 KILL REMAIN CHARGED HITH THE HEA95 IN THE EX5T LOG. : I MPA - KE5TERN �VOP PROPIXT5 A5a-Or,IATION MAX, - MAXIMUM (I - CENTER LINE . 1� . I I . I I , ", il NOTE #14 6.6. TO PROVIDE CONDUIT 4 PULL 5TRN66 FOR 5PKR5. TENANT VNDR. TO IN5TL. 5NQ. 5Y5TM. VIA MLTPL. 51TE V5T5. 6.6. 5HALL ; 1. ..A-1.1' - ARCHITECTURAL FLOOR -PLAN E5.4 HVAC POKER PLAN I I DRAWINGS ISSUED FOR: 'i�, -1 - 5OUTHERN PINE IN5PE(,TION BUREAU � . ". _�AL2 -ARCHITE( ,TURAL FLOOR FLARDIMEN51ON5 E35 FIRE ALARM PLAN . . I I . , i� , � . , 5PI13 1 COORDINATE NTH TENANT VENDOR. I - I 0 programming . ; , !!,] - 43 � I . I ,� , ,�: � .A _- � ENLIAR61ED ARCHITECTURAL FLOOR PLAN5 E4.1 ELECTRICAL PETAIL5 .� . I NOTE 915 ALL HEA95 IN r_7YP. 60. GEILIW-6 AND LAY -IN TO BE, FLLLY REr,E55EP AND CONCEALED. IN schematic des. . 02.0q.Oq I � "�' . .,'A-1.4. ENLAR6ED'ARC,+iITEC,TURAL'FLO.OR'PJ-AN5 E5.1 ELECTRICAL 5PEGIFIGATION5 I 1 1; NOTE #16 5ALE5 FLOOR AND DIVIDED FITTING ROOM MIRROR5 BY 6,( ,. AND IN5TALLEP BY 6.6. --- - �'A-1.5 ENLARGED -AR( ,HITECTURAL FLOOk PLAN5 E5.2 ELE(,TRIGAL 5PEGIFIGATION5 0 design dev. . I �! � , t . 0 bidding �!� I I , ', . 11 �' 5YME30L LE6END PROJE6T KEY PLAN PROJEGT LOGATION PLAN I , I A-1.6. -DECOR/FLOOR, COVERING PLAN � M permits 0116.061: , ..;- . 1, �� � I .. I A-2.1 ,REFLECTED CEILING PLAN . I I � I . I � - . 0 construction I I' 1 �. I "'e, I � A-2.2 �REFI ECTED GEILIN67 PLAN - LI&HTIN&DIMEN51ON5 IN landlord prelim. 02,.0q.N .� �, 11; I � 5, I I 1511 . 'i . 5,�, "N 0 ',.,',,..;, �, .., �� �,,��:,��.�, �i, , t:�OkW'Ik I- ��,����"",:,.:����,�,�".�'�,.","�"I". , , Qlkw 2 i i � , M__Q_HAN1 . I �1- , , ,:14 "', ::5. 1 . 1 -23 9EP REFLECTED CEILIN&PLAN 02.27.Oq , �N � �: .� , A.F.F . .. . ". .. .... - .1 11 I 11 I � �i!,� 1% A6r,E9Y_RIE5 :�'��:�; �:.�'. z- �, _.., 1�. ft,;;; _0 -A ENLARC 9 landlord final I- , - 411:11,V j I �;� �,_ . , �11 1, CEIL :" , �, I I MMING TITLE �.:_ �.�1,111"-Ii'..".,--,"i'l�-,� "_�_'A.111 E ., �1. __ ..,,.'�.-�, ,.�.._. If'. � ..,: REVISIONS: � le - , . �.:,�: � . 11 i-_ . W -W, I. tYPe -1K TAG TAC7 �.,. � . ,��._��-. �,14s�'�' - -." 4. ��i_v, - .. -1 1. , A-2.4 CEILIN& PETAIL5 i . .1 - ". , ;,a 141 I . - .,��,, �:f�� 12 I .11,111,1111, . ,,�, . . -, '4:�,��, 1.�_�.,: I I . >.�?, '. I - A-2-5 ,.(,EILIN6 1, , "I.-."", _ ,,�.�.::�.,,� �: , - ," * "' `E'ki� . : �,;, � :X1. M2.2 MECHANICAL LE6EN05, DETAIL5, AND 5r-HEDULE5 � I SCALE- ( D,--- "� , ���",*":��,'��,�"�',,.�-,,��-�,',-�,��",�,,,,,,��,'. ,i,,',--�,,�,��..,�*,�-�.,��,�:,I.i�-.�,��i.�..� g,� " I , fini5h . � , ,z ,,�t ,�� I ", , in-t,�,: . I - __ I ,?,�,.'.�?�.,����"),.�",."��� �, . , DETAII-5 I .; .�" , . " , �': ` -- - - � I �, -, .. ....... . �� ,:. ,:�� -�j�p,�.-�, .1'. � i , " , �,`.`,! ., -.--! .k � , ... , ,� , ?��:, , 11 I ...1. . - . : , .��.�. �E �,., ,;--:::27. .W. . �' "I". . . I - 1 " 3 - ��i, �'` � , -3.1 " . � �, � , _:"1.#:�<., 41, M23 ZONE GHEGK5UM5 ��,.�..`� , � WRTW DOOR "', I"i. �. - ... " � .", '. .,-,! , � � %� ��. , - . ,�i�l .�': ,. . ��_,:"��.�-�,:�_ �, � �i��i3 ...,;A . INTERIOR ELEVATION5 ,. i. �1 . , N1R.2%.<. , A . �Iia , �, �§Q, , ,� ./ _ I , 5PLAN 1 !:� � - ,� �,�,.;�]: *��;,. ':�,�x,K t.","."'M , I .1, . �L_M....M.5.- ", � �� ...M_'ix .�, . TAG . . ,� tv,�...NIR,�_,, �:., . - ... 11 ... - ` " ';14� . . .... �.L` . ,", � '�A-32* 'INTERIOR ELEVATION5 M3.1 PARTIAL PLUME31NC . ........... : . z',� __ � . ' �� x� ��,�� �,, - . .1 . ,�� I ��,�,�,,�,�...��,.*�,��.�-,,',.,,,I .1 - �,_�.�r, �. ..., �L i � , - " � . . -1- - .::� "' I ,.: :,� ��'$'. 1 >1: � 1 ;1 11 �, MECHANICAL 5PEGIFICATION5 , _ , . - . g. � :_1 i " ,,-.._*,,* -'*` � , , -�,�:7 -:�, .,'. -,� ,* . ., ,-� , I �i_ &-,*'. I _ , �� M4.0 I ",4 �:�:I,�, ��y�,��: . - , �.', '.1, �.ii:-",��, - R., _;e,�.�:.'?,.�� --:�:�� �N;1; I , �:��:i����l',�:':,,���,���,-�t�,�-.*',,�,� c?��-,�` .!�, �z% . � � - ."I 1, :� �� '� '� %��' 5 � . y , , _ ::�..�, � - '� �" `� 7 - ��_ .. �, ���,. i S . �� .� ,- * - � - :. < �,: - ... � �:�_ , � ,,�l�'�:?'�,,,��'..'��:._.i-.��.��'�4� �"� 7..,."��,11.��,� � .. DETAIL - �Ts; Sit _Ti��*. _.,',� :��. � ... �_ �-_�', '_',".� 14�7! - , I :1 �� , � ,�,�,��,�'. tl�g, _ . . _. _�:,_ . . .... - , ,.'�, 11 11 :'A-33 INTERIOR ELEVATION5 . .��, . � , . I , . - I , _._� . E �, ,� "I � ��:,�,� ,11� ' �I'LR W-IBER . � �", �. , . -�,��l �,,�,'�,' �::,<�f, -� f,.-.-.' �,��',','.',", �-.'-,","'�,�,,�-�-_-�".�"-- `� � .� ELEVATION . _ �, C�c � . 1�- �111 ., " , �_;.- ,�111 ,pf,�e, ,e;Re.g 4 - 1.,, 11 �, I-- I—' 7 � , I lgmr - ,�,�._Iwi. I.. G I .__ - , ,., "" 'il&k iu_-_��.,�_--... ..'r , - , .gg. . . I �','..._.,_ , 1: �, _ .... ... � . 1, . . 'A-4.1' ENLARGED 5TOREFRONT PLAN, ELEVATION ETAIL5 - , �. 11", i, . � , , ., -, 7"_�. ,-, 1, �� " " . I __ �. �_ � �,�� - -""- '�v- .�! __"�,.,�7_n_,�`_ _,i�, 6, t 1�111.1 - -� p . I ,_.I'i�,��,. , , . V , � , , ,� �� I Jm,,,,Y.it �,,-, .r' %�,�_'., I I I!, � - ... "- ........ ... .1... _ 1-1 .___._ ... ................ . - �,,;��,��g�, ,,'��,�� ..� .����. -r I �"f��. �� , - -, - : - � ��,s -�Rft . ,� - ,�., .,� � , , 1. , � � I � 11, �� ��',,, � ,i. - , AND 1) I � - . ,,,�,; �, - 11, �,,',. I; ,�I, ,�n **, - ,,=.�',t, I I I I .� I I ,. I - . I I - , . I ., _ � ,��_ .11 , I _1% ... % '. A-4�2 5TOREFRONT 5E(,T]ON5 �, � : , ; � -,-. .; �* , - ,.. - - 7,, lii,'i�,i�;��- : , .� � . ',"'�.. ; �.I, ? -,_'�'3 - - .. .� ! ;��.'.' ��,, , - ,_ I �- 's .;,j f �', �? , �! . 1,�,��,�,,.,�Fi :�,�,,,' - , _� - �. '.. ,,,, , , I I I - - ", lkl'�E_zll * �N . - , .. w _,N,,,�:�, ;�, - I < 11 - --- I . , 7 ,.�. IL V ? KFYOTc � - -, ,--,-- : .- - ,,, ; I " � - -77� - --��, - ." - , . � � . - 3 � - , I WAIRS , .,�:Fr ,��, � � �'� �,,,_�""�.:, ,�.",,,", ,"', . . . , C = . � : � � -1 . : r?� 1) A TITLE TAC7 t. -1111- : _ , — JCPenne : �11- I "::�-�.",�'__ �! 11�..�M ',�E_�.'P_l i �'a �Inl.,�-,�,"..,R ..��.�..-,!-.,-"��.<.It.l.�.11��,���,.��,�. _ 5,w,` �.. __ . . : — '11� __ , R. , , , �, .. '&'�, � ,� ,� i , 12i; __�.1.1111��.,�! ".., , � "i �, I " A, , " .- : - ,�� '. " 5. , 0, - I , : - -�_ __ "C':1. � ,,,� , "�'. - -.',�.� ` 'ill& �,�� _� , " -,;.z-.; ',�; �,F�:�* I I - ', ..., , .1 �, , iE." ,�. ..... � ... � I ��, _., .m. . ", I , ? ". 1. L. �,.; � y "'i I : : 2 �,.� " .1. "... — .r ,�, j- ,_� -'�', 'i,-:., '�' '� �,_ . .� ? �i�,i,,,g'�"", -,.-,R,��g �i-`4 -'�� 11 - � � .4-4, Z,,,.a ., � �'. m? -4" — , :. _@_z . � :!� __�,; Qt.t;�... �'14 . 211.,111 , . I . z �,, <��.�.� � , , - 11_::-,� _� .11 - , _-,_ , . - �__ , - .. _**� " - 1, � - _,� - ... I - I ,.�.�_',�,*,� ", .,.,�i "��,,�,�, --�;�:�`t`lfii.��'e �;��,k4,j,�,�X�,=W, � — , : � " ,�i M -ND ,�`-,�r.-- �,,,� �:��;� DTI -11) -��4 � t� I... ,,,�. ., � ; i - �. ��, - 11� . .1 . . !� �,�SACA EW . . .__ 1;1�,' " - . �__ � ; . . ; . I . . � � W ..'... _ LIE-- .5HEET REFERE �E , .i.41." . . . z ., ., , ,� R ,., .�,vU�i� � t " , .j : � -* ,��,,,_.,, jp�_�',�,`,�,,�� - S , 1� -,,�,,_�.,.i, .. I . ; p ,; t_; � I I � ..__.j _� �.�.�.:�:�,'�-*,�l-l""��."�.,� N_�., , 1K . ',',,,;,-:�,,�_,2.`,. . . ,,;:��,'� . ---' A-5-1 HALL 5E( ,TION5/C)ETAIL5 - �� ,�.,,,i, -; - �i.� �,,;�',',�--i*��!� %Q� "i" -�,'��- "" W,'..� ,_,_�,.f�;! ,-,:"" . ...... �:: . . . . . . 1:�, I :� -22 _,;� '' . � :�::�O""..`,_�,,,�,i _,�2ii, �, .. ,,�,.� ., _0 ,,,, . i�,` - 11 I ?..!_:',,. , ia - �. �, I � . �, , � �,, R - .". , , , , "; " _' - .'��` ....... >"' .,�, " , - -- `- . -1 : , . _T_ �,.�,*,',�-._.,,t'i �,� I 5HEET REFERENCE �Ii � -.- �, - 1. -1 1. z" - "-:4��, , . ,_ 1- i � � , ) I . ,� I-, 11 - %:�.-�.".�)-�:."7,,I'��,��-..I�r.�7T-, " , � ...... :,I��:�. �. . �,7'.. �.:P� � I ! . . . - a� �._ 11:,�.ff � ,,_ * � - - - - - ., ;��O�f.,.��' �,�� I ", . - .. ��1111 .. - .� 7 . : � .:�, , , . . _ P..Ai'.�i , __ _.. : , - .. I 11 I I 1: 11 I � I .,11'..1',..,_', . I - - - - - � �� 'T *. � i'� -1.11%. . I - ! -�%,, , �i,', ,,, " �F,: �:" , _��i ,.�,,,..,,; �;,..: �,W ,`z�`,g`�S*:� .', -�:."",��"."::""�.�":fi.�-�i^",�, � " ..... . � I - - : � '11��.,: 11 � , I., � ',.::,"�,'�, ") �.,,-','� � ; � '. �:, _i�.,'.',','.,.':�',,',.'1. ,.�. . , , r", � ��.� .,,,v _-, , "' ,j 'ZI .'.,, i, .-,��.",.L",..,.:�",.","6-:§.""�5 , . � I.. ,.� __ : I . B I 1. I A � V � - - - .,����,.�,,,,"�!:�-.�:,,��-"-.,.,�, -',`.,,,,�-', ���'-�,��,�,,�>,."�-�-.�-,�:�,-.,�"., �-.', �,,� `-�'..-`�1!0�.�'-,!, ,.., i 1E 'A-53 ENLARGED BAC,K OF HOU5E PLAN AND DETAIL5 , , �_!3'�', a ,,�M.'._ ,,,�.�, �', X� I I - $ 1- i . � �. __ � .- --- - -, �j i, �`O, ,� . , - . " I-- - � ,�,�� 1. - �, � . . I ., :�, ',�, � . I li ��x - I I—- ... . . . . . - . , � . " 'i., I I �1* .'. R, I , ". �, � 1-1-. . ', -, . ' i-,�i:� � R. " ,,.,gn��-'.'�:�-,,i "i'gr ,,.,,,, 1 , P'. .1, '. - 4 , I", , . . . fi.�, � ,(/) :!:,.�i'i . � , I � IT ., -, 1� " . . , r � ,, IN 1:1.�!il_.,��`1'010'-':: ... ��; - ,.'�� '7 .�,P�'i`,,5-,i"'." ;4,-,��.,,�4. k -O"', i,'� ,.,��"`?,�,z&�`.--', ,_ " � � � �lu A �,�_ I � -g 7 , � �._ ,�,-�,:�!�:�.,.,,,.',-�'.:,',���Z'�.,7�',., MJMBER �� 4 ;`,,�`4 ! I', , - � k I " � ,��,,',�,�_,__`�2.1 ',� g" ng , . iW: ..... -, I ..z `��- -- - ,A -a52 -ENLARG)ED FITTING ROOM PLAN5 , ,��, �� ., t.� � , �, ,. ,1 ". - - � , � I ,�� ROOM � � . . 11.�"%111 , ,',':�._ , -- �,�"_Okov, .W I � - -1. , i �� C -� .'�11, I ,:,:'�. , , , *.� � , , 9W , " - ')E516RATION , iv,�,,. , � �1,��, . ��.. . I I � I'll- . . L _�, .1�...,.""�,�,,,..,,�.z��,�,�,�,� ,�:.<4!.-XYeAi,,W_. " ,,,��; ----� ,� I, -� ,',�.I,il'ii N'li", , . 7, . � g,� la - � � : �� J �;_. � - - - , '. ;-_��,:. , ,,,.'�4; '_*�',,,� I", �� , , ,.��_��`!,��,', �1 ,; �_�:. �'. 3�i �,,�', Pj� g , WMBER , , __�, fg�gg�, "P. � I I -,�_ 1, .�,� I . � l-, I 2;�', t_-; . . , � � � . -� - , ,��.;: & �.;`;�Z. F I - V; . . ? �_�. - - - - �,�:,�,,,-,.,�z,�,�?�'k;"�����:,�,,'����,',���,�,.,;!,��,!�:- �,�"���.-�,,.',-,,��..',,��:7,�,,��",�,7-- � -���,���,,�/�,�'.1�i-,��"if,��!-,::,.��:�,:��i ,',�,`: �i* R, a� - �f -�. . jl `� �_� �- "' I'�',�l.!�:",.��:i��;*"��.:,���:.,�:�,�,11.�,,�1.1�I .". � _[= xxxs.F. I . ,,�� _-� � ,�.11.11 1, �- I - �� ., -, _.,., - �;, '... -, ,!� , �, .�,-, � -__- � - :$ i ,�,�,,. .: . . I -,, .111, - -.11:1111M.-I., ,� , � I . - - !-_<,�! . s I ,,, Z,, , .. I . 4 li, �1� x: �,, - , - -, . 4 11;;�.�i_' -�,',,,�.`.�'.`,.,`.� ��`., �.�,,, _', ., K_1_X,_,!fi1'. 4 . . - , j .. - lv� .,:, ,, , � � , � . , ,. ��' I , " I _ � ; " - I _� , m �, �� -�%,g..�,�..� - 1,� 11'. _,�:� N"t , -5A .1 - - : "'..- , � I I I I . 1. ,;��:�,, � - " .1 "-7"��,',,�t,��,.",�,',�m,�;,*��.4 e�',, �� I " "', ". '. - ��-:Y�. :*�-;--;�� 0-,i�>�r �-,,,,�,44- -,.,v . , , I "' " I :�._ . i:;! -.1 �. � - � I �;:�,�,���- - :" .: I I . . - '..,�U,��I,--��,',-0,i , 1, -, ,,��i , .4, :;;,._: - ,� I / , F � i . A-5.5 MIS(,ELLANEOU5 PETAIL5 I NUMBER MATERIAL 6HAN&EE ' I I I 'y', , , "", I.. . I � - . � . 4,,�:� 1�. �":�_�, � -, , i�-�,-.i��. ';:: ��7,. 1- I - i . -,�, `� ` " ; . -- - :;`�',�Z_1. " 0�1` I F ,� ,,,, . , I REVAWN >-- � I , �� -'.-,- .;,wi �.�� ;' I �' ..�, . , " , " ` _. " k [��Wml I _.."... � . _..�,q , I �: , �f� �n.- __�w. ,,� '��, `� � .�� I '."", - - 4�v.,..,�!-_. 1- - .:�-..* ., _... ... , %..'�.,..�, ; . - .�".�. -, �� " In '7---,:"-, �'` 11.*'.��. , " , , ''I 'T.'� A ENLAR6EP TOILET ROOM PLAN AND DETAIL5 ,,, I i �! , ". ,. " , .1 -:.1-` . .... i .... � - , , , 9 "'.; � ,;.,, .. , - _.. , , ,.:�' . � �Q :.'1'17r'1', ��7,3,.��I.,,,�,�`� .,':,,� -.,',-�`.., �_ �A , , __ 1� ,/.., 1 , �_ 1. , , � . U_, - " I . I � �, , _'�_ ,,� - q,__ -j,--. - 'n - ,,� ., , E.Fi��T - , . , , , " � �* 0�, . . -1, 1. , 'I, , .� � � * 1�;:, `� - �'. .". r7 � ,�, �, �� �,�, e " �� C;.�z _ - - �. f 'd .211 � �r; ,� .,�',`61111 �i�51, - �.1-4--_,"'e,�,", :,,���:����-�,�'il,',.���"..-"�,�� ��.-, , . .�, � , - � . , � I .1. . I . . , I , 1 . , , � i " 7':: . �L4i " " - �'. �i. " 11 �11i. , , ," , -'.��, "O --, i. �. ", 1 . .t , . , , My ._ � � " .�.:!�,�,������,����,,��,-.*",�z� !�".�,�,,'�,:A � . - I � -i .... 11�1111 , , , I . - I " �, , , _ , :11- , i , . , , , . I � 1- . , � il . ,-- A le , I - , , , 1,i*�� , � �� ? ., '. "%, �__i�� �'.* " �., �- � .� ,��, 4*",., 1 - I I ,,,-,,-, -, , " -41, �, , I V, , :"�� :,�.,... . � . I '� I '. 1, ,�,� " "" .� * , i,Z,: � " 'p, , -�',', " ., � - '�-,, ��, ". " � _ . . .��:::�. �!..,..�..'�,, � 11 .1 � � � ,,,, �. . � . - , .1 t,�, - � '1�, . I " " , . . �::..,...,,.� i� � ., � ,_ _ _. � , a I .' ..,. : ,... -, , ` ;....., ,... -� ': . � , , ,; I NUMBER I? � 14�� PE516NATION , ` ., - �-, 1 ,,, - ,\\, . �� - '' ` -- - , "', % I , ""��,*,,�,, , _ .. " -, '5P - r � � . t,, ,:��!fl .- - . - � I -1 � , , ..,,� *� ,i�--.-_o'� J;�,����,,�,�,,��,,,,,�,�-���,.",�,.,�.""l�i�4�-,��,,-, z ._;!,-.,., �',., !,`.�.`,,:�,�' " ��-_Iiiii ""�'�,iY�',�'-,Tl�,,��:��!t�.".!,Ii�-.1',��',�t�����'��,�,l��".,;:,�',",i,..'���'�!�� ?W� ",, X. z � -�,: I -) $�:_ , -, I �� :, �,: " ,,', ,,� " �_*.w : . �-.�,�.� "'m ,� -"�qu,-�,� �, -,s "...'�:,";-,�,�", ,, ., ".", , ., !;, :, � I ! , I v--. . I - ..., '�_ - 't. , - _ __ _-11 I -1. - � ... �f�,� - .: � ,�, , � I O.. M �A,�',!i'�Q .]-,%�,*.�'.-:�:�',�", �,����,-��,��,,*�,,�,'.:,,,.'i��.,� 11 : - lil _96)�'n,�V.'.,, ;.! . � . .�.'S. �:� - 1 s�& , 1� . : , '�,��,`��', - -W�,',, �.?Q'�,� 'p - -� , �: 1:1, '." -.1 ""I y I -.0 -1 - - !,�, 1 �'W.� � � ", % �, *,�': �: �: � M ,.,.,, ig, .,;6�, 1 1 , , ,., .,. OT N� VC, I I ��,� 'k�� � c._ ,. 1--,n �,,� . . � � � , "', � . . . � - �,� � �'. � : ,��.:Z�'�,,��, o..,: ��_, ;'�'. ", "" : ,,- , ��,112:� �,, I ."": - , � - , '�",�� ,� - , I . � �_< IdAkk, . , .,. !, - 'i ��,A_,% , f ; -" " K", "'I ', � . , . - , � . _ , ,�gw, �j t4� ., , I .. _ � .. %, , Q. �,-,,'. g � _,i i -:� ��111,0 1 1� , "" , '�, �, TM# .,� . : E!�'. '_ , �� _ _ � �� . " v� � � .. , � �, _,,�� � _ � : �ff* ,� I 11,Z�,�.11%�,',�_ I ..��N t� 'T _1�1�1*,�' 1'� ? - " - - , I -,, 'W' j , , ,� I �1 ,3 , i ,,,;,;-: , , . - I—: ... : - ln�_* :_, : 'il,' "' � __ -,�, '� � , , ,m, . V �� IS I . 11�'� -- 11 - - - . � . _ � ."_. _ , :� M, ,.":�, 11 ... It , ". . . � . , i _�r a� tv-, �,'� �v , , ,.", . �th�, � iJ .�g,.,� , , : W '�1110 � �til_."�, �"?" --��,`��, _.�?,;,'.' " , 5HEET REFfRB , .�; ki :1 ,�.. - 5� , . _-, - , , _ 1-1. I IT . /� I . -, .� f, , . -� , � ,t,� 1, ��.,J�pp��iL7. ' , f - � _v-, - I �. , �, , , ,��,_.� - .� I . . _�,�: �l":�",-,�,:���'�.,*,�li.",�'I'l� ..,��.*'.�: , . 1. � , " � 1`1 '��`QK:i*i,, ..,-. I 1: v�j . I I : �� � ". �, , . , - z g.,�-_,,_� 121- - t" - _��_..__`�i_�',' . i,�,,�"!�,�!`;l -, �.,�, _� : . , , : , , 4 ! ., � ',� _,%:�: , � 'I � " 11 . A , :� , ...... �Ig�. � �4 ,.�:�� . . - , � � - -,�p -,_j_..,_,...1 ,.:, I 1 Mw a .,e -1-111 - ."'I'l I � I . MA13-FR - I , - " � , '�i", -.,], '� ".�."> ,�`11 I'�'If 14X:6� , �!14; �_� � �, .. � �. %,.,;.M . I :'. 1 4 � ; . , - � " :� . � . - � j.��..�,,'-�.-_� ..... .... � ... . .. � , " I i: � z� ,!* , ., , - . . i��-�z.,,,,,�,_..-�-.t,.-,���,�����--,,��'��.�,�:��i .--.�,��,�i�;;,'i,,:i;�-e�-2�;�,�f , I - ff)01 , _-.-1'--. '4w ! :1 : _ . .... .1.1-1--11. a�', � I . - . `�:` -[,J�'� n,., '1_1=..;.�_ . - �, � '�� r", .�,, ; . - - .. ; ; I . ,�,, t - - � INQIIMP-15i � ,I "A . I � , , W_ lk,�F,.,� ,'.� �� � �;'.-�n - �',�,��- ,-."L.i-� '��:,*-,.,,,-....".'.,5,"�,.-,!,�q-,,�f.�p'..'�I _ Kt,� ? - ,-11, , , "! ��,_ �,��� _1 - � . -...- . ......., , \'�, -.1 � . - I __.____ . � . " I . - , � ., !, � _," :-"-.-, 5HEET REFEREN( ,E EGUIPMENT TYPE �:, ` , , mr , , ,� Z, � , . , ..I., I. I '. I .� "41- I �i 11 : X;l I �. ; "I, `� '.., ,_ , .., __ _. 1 �,,�k t 4 . t. .i , : I ,,, I . ,% 11�11-A_,;._" ,��..�,.?. � I :! , _; -1.'.,�'.-.',p, . . 4� �,., . : 1 �� :. I : ; . , -,-z:-__; ,.-. - - , -1 N 11 -11 , �; � ... I � ,qIx- , ,z��, �' �z I : � : : � - . fq_,� k'111.'.1W.�ffi � - � �,W ,.-:. ". ". 4!,�. ", "N - . , - , z : * * I ___ , �" �� ___ I . . .1 ,". i 3 .. �. 1� I : : 1�, . - , " � I I ;, � - - n�� , �,:Z;; 11, a:.. .:� I - __ � �t�_ , " ` - '� X -M 1-,i� __ - , _�� - '.�.� _�'� , 1�1 "M P ii� . , ,. . . I . , ��k i��,��, ',`-,%D"",,.".- ;k��,,, .. _1 ,� , - �._ W 1, i �<� ,,, . t j��,,Ml " ��*.,.i'-.,4�.,.-iT,,.�".:�,��"";,�,�,,�..I . . . : I : : � ., . : I , — , -1 t : t � . : : ; 1�_ ,V.-1-"-& -, - z; � _, - --p-, � .. .. g .e . ..... 3 �_ :�,��.:."::, - - ... _., , �, p,��, - ��? - ----),,,e t , , . ,:,-,�' ` . ( ? ____PE,5IC,NATI(A � - �y� "',;',.i-�,�;-, � "'A nlfl�,_,_I'i; 11- ffi.71`1�'�",_,`C�V'i :, t�-,...::1. �9 _ , ;,-A�,im , ;.-,=,17_ ,-Axp. v,.,�",�. 1_� - _'u� -, , � ,,"... ,.P"A,, . �,jj __3=M'.,,3 M _"i'tl � �t . .. , ,- - , q,, , . , , � "JMBE R : . , - �'.. . ',_�� RJ`10,� - - , - ", , - � g g4 , , .�� ... - p. -��.,-," . "."� -�,g�, I � �, r, - . ., 'U'l- -. , w " " . ''... , ,. 1_.�.4 WEW COLID"N � , �`,, 11� -�, C'� ... ,. , , - �'. , � ,'.�.._. 2--, , -.7,* T � :; , - I '111A`11� . I , - I -111 1.11.11.11 -,- I '. sic , ..1. 1-1. -..i, _� � . MAX)VU11A ............. �.. ; I - I - 1". ... . �.. 1-11-11 �j �-� "� � La ,;'i kr � I VE5tGNATIOM MIH RORK / 6A5fENMRK I . n� � . ... ". I §'-,',!-& Effig,,O.,-, ,,�, g., 1,,'��.11 �� - .1.11' 0-E, I,",. I.-,," !.-_-_J �,! .�4'" ,��,7s�*i,�,�f,� ".'. ����', _`,�4z,,,,-`�*�;' , � k� . -, - . - I. ... ��'Z�.�R',`;��",� . . . . . . . . �:.- , , __ , .. - , _., , t v!� . 1. yx� _f . 11, '11.i,l - _,�,: � "d .. . ... . , " ,2ffi,�,fi .. . . '.5'. 116LE ............ - - " - --- - - ,MW NW, ,1,� `� -.- "', , , , b-�,�, - ,,`p _��, � i , , --, ... . .. �_. � � , �� -,j�,,,;N,-,-_", ,,�, , P,,� ...... �� ..����.�:.,'_' ...'N."".5" I 1". -Rhiks, _________ ... �� ..... .. '_,�,� � "..""""! ',-.,,.,., A_�� ," , PC -1 't. , - , __,i..,,___ � ,. - � _� � I . I . X� , , " , - �,_. . . .. � _: - L , I . - - -1. __ . , .. A- " . : -, "::::, ;� . . �. 11LOING AA- .��?,,�.,!--"�,-���,;,�,,",V,'�, - ", "'I'l-l',16 � �%��, . .� , -,`.. q- -, ., BU rA ,�) y I /\ - — TAG . .. ,..>.,,.\ 9, ? I EYD�� . t', .3, "., 111.11r%� , -F, � . ", �, , I ,i�,�.` ..k +,�,�..�k� " , -�j --1 Z . . ........ ... : .�� - ,!�.W n,_,�-�'.,� , , ,�1.'.'3 �,; � . �� � � �N�, ���,.'� !: . _ 11 . , . � . � It ,., _X, x �, , �:,.W,; ... , ", �.. ,." �, . �. � � :�.� ., . d. , � " ;_ , '.. �� , , �� 111�1:; � ;. � � .,�: , ",.�"--�,,z-��l�-�,,�.��.-,�V. -, "I ..�. ,,, ..�11 - - �2`,�,,,-,-",,,-�,. '. ,.� __ . - j MAT6+1 LINE � I �� - , .1 -I , - - - " �e ,:�i.',.' 11 �,,� .1; .��,�:!1'11��'� " - " ,4,t, , �,�,�,�,,��,�*�,,,�,,�i,',,,.,7�',.,"��,,.����-��,�,,�i,,,��4--.,��,.,-z+�'-�: _,,,+,�, ,=, ,,�., . .::: I � , i I , (Be(k _�_ - -�..,.,�+'+,+.,-,,�';'.�"!i,-,��,.,.,""",-",....."......�i: , - .. Prj. no. 8-209 012 1� , ,j�� ��_ �., -, . ��',��!�.".��"I.",�",,�����l�:, . , __ .,:�,n N�, 2�.""'�,-.Ai: +� �, = _:�,,, ,.,�.,��,,+,,�,;�-�!..,-"i"".,.', -.'�J. fi: ,2.. �,�,t��. .". - - .. +_,."_,1_ ..0 1'11."i.M — , . � -- g- " -- �� 'Jil, `,�,�_,�,_ `A'o�' . ".." ..,,;,�?._,I�A 11 ,; - -t—`� `� . . _ ... - . �_�� , +:� .�:2 � - p 'tt'll",-",",�'�.1,���;��-,�� -, kll*', il�-7e, ,� 'rt . ". . . . 1�11.1111 t. .�-_�,,� ,,,;.-,�;7,---., , .',;�t��Z,�a�q-gt,� - _..",", "_�,, 1` -, �.,.�M; 11 , v-- ---"���-�,-��c:,-".-1;4;�.�,�,�,,� ........ _ "", ., .�,.,�,� - _::� , � I x1 .," " ". - i _.7, ,, � , . ��, , ._ .� - 11 "" - NLAIBER - FLA6 NOTE � - _p, , . C �, - � .��; VW1 "N� , f .. I �4, , . , . . .1 .i;��=` .M. I . , � 1�I,e. ��K,,_'wi�,ffi*,�_, . ..�,,,'W_._� zlh��k�.. , - . � .,. . . , �, �,. - ,�,,,�..'� �.:;;�'- 14 -11- "I I � ... - , u . � r. I 1, : � Ii , I, q- I, _� -, � `� N ��,,�-,� �.� '�" - .!, $3�,�,��..:�Llill�:�<����,�,,*�,'���,,,� ', , '-�::,._,_111�1...`T W_ _,,;,..,�_,- I ,,'� ,�' _.�',' _e , �,,, x , li,� -,";g. & 'a 1 _ - �""'g I f . , " I , I ,0 .�r �'! ""�,�--,4�; , �,�� + .,� � , "' , "l- """ �: -, `rm - � i " . ..1.11 � ". _', '. ,'��. �� . P. ., , I , � -.1- 11.1. -1111.1-i .N " .,5� mli-- I,, -tp V. ,,,, �,�,+ _�.� t--,,; ""i"Imm i [:)A� OF ,, �> , 4", �,-�,,��k"�,,',,,,.*�'��-,.,�,�,,,,�� � �:]� ,:��"-q� - ��,�"."5 -,, -�-V'�i �� , Drawn RC, Tk4 - - * - , �:��E,',�,* �._ '. - " . - - �;�--u,�6'-"�.�:I, `,�, � �+,�����,�""�m::�.,:�:��.�,;�,���, . �, . ,. ,k','� 1�,V " ��-��,,�.:�� -�� ��,:,J,�:�e_,,'7 , ..��.�:� �� r ."! a, i4PZ';,�?w ,�. � .. � , N ,g `,� I '' - _ ",A I 1� � :��,,,�p,��',',',,',,,�:,,,��':,',�,�r,,�-�,','.��.-�,�+,� '-A�-�'�,!�:- �fggfn I �, - , , I . i�445N,!�,A,�+�.. r.-�."._,�U',� -IM, 1�kollt* .1 1--1 ,."+, 1, ji i , . � -1 EXW11467 C.0 -M-44 5NATION .,��'., -5- Jp�`, ,+i� ".-I., , I ". - -, ,+`.,,,� . I '. A, , -1 . , , ,,, " . .." I , - .0'. _516 ,��,�.:�� � I ,;c , DRAM& GHRONOLOOY 11 194IT2 - - - - ��,,_�w ,, - � � RT _A._� ,�,.:5, �, -1. wvl , - - __ - _:� ... ,:. �_ . ,_ _i�l . - 51'. :, -, : u I I . . - Q - . , I " A,�t . ` -, e �� - 13 � . 111N_X�15 ."il - - , , ,., ." .,�,P',i.'� � - ,� " , _._11:'.,,�':� V.�.'�:,�jj:,� ,,,,, " �. i . I - - \m;� _ , , 0, -, , � , -, ��� - - ; � ,� . , '' :�',-,.,P,�, _P� ., , - I �3 - ...... A 11i - . N �",',�.,.��",::�4,�.,-,�,!���,i-."",��,+.""",�.���;,,�,�.�.,�,,��,.'�,��,,��,�����I - "'g., a. ,1� ,-W�T:";:,`,,2,,��:." &.i�,�,� �, ALS . �1_ ml-. �;,�:.,�,.�,�,>,�,-��."!;*,.��:;��. M � - - - .. , ", cl ... - I k4U , I - W�_,.A � .,.,k��11 �: - - ", ,.::`�M�. �1� .,�...�:�11.. - I - I I , 11�"" . ., , :�� '_��- ,; Approved ... : ,I � I � - , ..., . .. . r, ", .. , ". , , - I "�'.. :-o�� ': -'�� , .kq-, ,��,,� 14, .1 i . ":v:tn,��_ .'i *� SHEETS AFFECTED , . , . ," 1, '. 1��`+` - , it ',�� �. '. - W .:,::.,;,7 .�,", .,'�,��l"!�,�.��;-�,.�4��"-��I VESCRIPTION , �4 .,_,c I _? , --- I lu*�`.:�+',, , � NUMBER DATE .i'm � . _ �M. , ; . . . . . �'.. 1:. -2, -, , -Z`� "., -. `�.� BREAK MARK ., V , " Jim, .,__ �,'��.-,;,'�Q��z � ,� "', , 5HEET REFERENCE � . '11,i � , V - 'i, � `�!;, __ 11; � __,..�..._, �_ " . A " '='��- i� .- ., , .. , — 2]t,i�i+ ,',�+:�,,,,�,-"","�"f,--,,�>,'.-,�.i,',�,-- ,,�,�,"-',�:,,��,�,".��-�.'�', gf,`��, -ff� ,f`i P�__ - :,,� ,� � .�. I I " � . , , , - .�", .� I _11 . I I . . . --�w, -,�,,x .11"'k. i,,',',�P�,A�V�n : , .�� �,; -,,-; ( q ,,�.- V� �. 11 ,- �,��,�-"; n , �: " �,,j r� -_� �'�1:�--,',�T,,N�4; - r-`&A-Fo, --',' . " � �,; `_ ... � ,,,�-�,_S, I �- - I � - : , _-,,,-1 . ..... t�v�, - � - �M ,�,p,-:, , .g _" , , ,�, ;i. " . ". , , . ... '�:� '�'�,'. `,��`, .`.';�,Jz, -:11"'....iR1';1.( �'.. _� Nlk�/�_ I I t)E51&4A'TM . �,',� I - _m tj -�� �, y , KN : . ! �_ ., ... ... ., _0 � -1 ,�� ��,�,., g?".--..-..'11��7..�jrj� - - ,F:'�:Z �,.�,�-;:��, &17'1`.�'�3�+"� `��_ , , MA-1EER . ��i�0; ,,, r ,.n.. " . i 1.:���,:fi, -'y"',�,,�,""N\ � - = . �"I",-z-1,1�"i ", ..",.. . � �Mw ... 11 � - " - , , - . " . , ,',�� __ - -� �.� LE516NATION . , -, 0.,��'j ,_ -8, !�'3�.�� _� . '. IA�_ �, .- , �,_�..,.i�� , ... ,,�i��::`�,D,&��',A,.,�' � ii� 11`�$ � ;��.-�-.`V�!;�-. ..",11"'... � i"i*1F_,..1,_1;. , -,,:�;_�`�� " , i, 4.."", �'1'11'11'R F;,�'�"'O "21 i.�_'. ,� �� , . �R.P_XP� ."'.1 ", .- I _0.-�h . ., �� � Qi!. �x,u. ....�', �..M;,�. = .. �, t , .e.:-:- '� � I , -, - � - ,� , . � - 'i '. � M, , d5 I .. �, _, � , . , .. ,�� 3 '!'_i,+� M. 1 - " '�. """"A"', "y , _ - �..". .,,,���',-...,".".�;.�.i����'.�,-.""��?11::�-.,�..�:.�,�!.�,�v�,�. ".'.,-�,'!�'��,�,.�.+."�'-,�i,;,,:,,,, ... i i;.� ,., �� ,�tfl ��,:`k,i, _�_MIWI;, � __ - �11..'�'_ , I ,, %,V I .111-M "' , .M,,� - 0� , � I _M M. � - � .:, -� g,,� i PARTITM TfVE �W!;49�, ,,, ft�, nw�mi++, +'� .�� , .��,,� I .., . / - ". , N � ;-�� i\� ,��,� �, � , ,%.".,.,�_ � x ... � - ., ' ,. �: , , ... , - A'PIR.-r K" � _52 � X�- � 1 lzzo 4 �;::, - , ` , , " - , I , i.-, , "_ �'.- -,, I' , * "' --t � - �-+ - -, - .',�, `10 , e this print. Use ,, Q, 111N,."'Et-11, ;",���,.�',.,����:-+,,�,.�..!,�� ,,'..IW+�, - . F0. ,�� �"i�'�.,` � 1, �.f,, �, �,, , .: , - - , �,,!%� , .�. . 11 - , - . , - ,� I ,,W�, ." I 11 ?,�.-, �� . - -,�",;'k�'�,,.�'�, �'� , � figured dimens nly. . �;i�N. -1-1 .. , - , 1�'_A�� 1- i,44;1(, W�`,�-,; ,,, �-,,� r,,.�,iza�A 1 �. AIW���,-�,-,:.;: �:::::: � 11m, i,.-�..."�.�.�13,�:�, . \ I A-1 N.. , . 4, ,-, , ..1.1ZA � .11 1. 4� 'y"X-7 _ 1 4, 1,�O;�1 ,`� ", * ""m , ,,�, 'M'.2 - - .'I I �,�*.E,.*, *;M:Rf+.',��, , i - � - �, .,,----- . ::: �_,_,f - . . �!,11,�:.. I ,z!3 , , , - , I ., '. �. t \ , . � -:Y',�,'� ., -,, ---,, "..". , L - -- , AM " - I .. '. ', . , " r , �%%'�'�,', �QP,��'-gig., 111�'s , Do not'scal ,�.��, _ �� �, ,,, _% N�0_ �,�,,�-+�?,�i,���,:,..s",�-�,l� r 1� .n'j�.,.i , , , , ", ,,�:,-, -` �', .+ i, ,,,�, , x , �",.��,�,,� I I I ��_,:,,M'�,,,� - , , . ,,,.�,� le.". - NO) Z, I E , I '� �� -, - -, , � -1, . " ,� ", --.,.,,,���,�-,��:�i",�:,.-..��,, ��-, ,+.��w,,,�.�;�,��,,���...,��,��,��l,.-,,��', - , ��:, - ENLAR67EP PLAN FIN15H TYPE H4M!5PAC:r 4FC6A �,_ mz._ . , - � M ��,�,,�,��',n����k,��t,V�,�,lk�,,,��.,��.:.,�k, �_, ���, 11�"..',,,��..',' ,� I �__. -,!q', ., ,,-,,,,-.� ." , 9 1i v 1 -, ,W . ., '. i, '_Q N " - , 'a.- ,�g 4, , �� F .'' . V -�,,-, -�i�,�,��,y.,+,� 0, t ."p � !" _.,�lC - , - , � , ". , I � . .,. ,�i",. , ., , , -i;�'.,,��f�'-,�,',���"k�,L�--.s'��.:,�-i'�!,��v�i,.'��,��.�',--���'��".�*,.�� , `;�,',`� � 0 - ions a , k f `�- ,�e,if�,�m����.��.,,.�,t,,.,���-i�,��,��- -- .�> gg+ -U�,� .."`.i � .- � . I � - �. , ., g@ � � .2 , t " , ,�EMINO_IE TO11-d,\9 GEWER I i��,'_'�"'1 I 6 - . T �, "t". - I j \ � , '. P�, k ,.��.. � �,l ..?",_".,",� _,';f��; � + " .� , . , I ,,.,. ,.,�_ E `�� I I - � I . , - ��, . ,,, �,. * - . - � :-,Ii-"-"':.)",�,��,���rr:"� .". "'�' .�;�,��', gilr,7:5.Tkgg�, , , i- , ,k�,�i�,�,�,. �-3� il,0�;,__ 1-1-.. 11-1-1-11 ,�-"g�,,_, I - �Y,i�iR�;�.�",�1,1-��.".�ll,�,���?1.1�"i'��.,�.�, ��`,,:]!�,�r,A� - ,,.>,,g_,., . . . I - - - ,.;;; ,?, - . - __ - -,E- ��_, _ - . Z_ - ��; .. .... k, f, �-:,�' ,�' , "., , �%, - , � , , -:�, 11 I I �4 I I , , �- � , 11-11 � "I E , , ` 1 X" -,! � , - ,j,:,:0�1' . . ."? . . . , , . " , ,,� , " , :� 1:j,�.�� EVEL ,3 -. �_ __ .4i.. _-,5=""�W , q . , , = _ - , , � _ . 1%6-�" K I �'Nlzl I .1 --t� A,-"�-� ...' ---_� ".", '�, 1� . ,zy,- 5,`� `�` N - G? �BRN,-2�-,.-,,,�:,, R '; 0 A "m � ", 1""'in 0_,21,,-'iT&NF-'< -,,2.'j [,.,� jy�,'51� �� �,//.�; �-`,��'-. n.', �,i " _ �, ��, ..� 1.11, ,."", j; , ,,�,_ . .. "', ", ., , - � " �i li.� . ____ Wl� _�'��, .,�-"-? .3��,.`�,,'�' �1'-,,, , -i�_1'1' 4 +1�z�'" , -.I- �11i6i�ll I - *_ .7 1". �� � N �� �_ I Aw - - , NlJMBER -1 DE56NATION _ �k , <�(— C-T-:::Y� �4 , " . . ;�� �x.,t\. ...... � " 1: ., ?.,�. .., , .1 ." t �& , , . I . . � ,"���,,�;,;�-.,�,,,,�.��,i�,,*�-�.� k'6,M, _i� -4. � - .,i14PV � '. _ __�.;.,_ � ... - -1-1 � (-.�Rw,3k + .+ , 4 ?�11�_11'1,,'.--' 4,,.".,.�: 40-1 I . " �il I .- FIR51,Lr - A __.�. --g- , � �.:; . �4W . - g', - 11 ", �� 1. - �,�i,�4�-,,*��'��.l�,t��,���,,�, .,,,-..., - . "-- , z_ ,?,' , .� f ,�,�, . , .,M �5111`_ , �. I � � 1. �,,,,�L �Kz��,..� -4 1 ---- ? -, -, , .m % "��.", '.' � :�� , , , . I . . , , , .� . . ,.i � .. ; z - , � .IQ ., i I A- - - , U, ._�_ � t!, I Drawing title: I I . I t , %_gl J. _t,gg=�:" fi, ,�q �zl��-'�`i 1:.\k . . ., I I I -g.- ,Oqaj�,-! �R�Itjv`_*&�, `��`�&Ifll'1111 14.. -�-;�1111.1'1 Ir . I . 11 ff�j � g . �*111 - =`0 I . I I . . I I �, 1. , .. " � _;��'N__`: __ ....... I.,11.1 -I.- . , , , "�?�'W�� �, 1, k , � ,%�.' " - � , - �, -. W"'I"I"', , I ` - � ��.,;.:,�-,-;i:-��,. �,-- ,-_� "If.00 V .7� i 01 - 4��, - - _V, - � , _." � I 's", � -��,- ,��4 , I , .��_ ..k - " � , - ,, , � '��-�.,4",�,'��,,�.,'��i,�-.""".�,��,��'I ", , " " - -� �, : _":�,:��,� , U'zl �g . ,.., INSERTION PONT - . N . _P_ '. � _ - " _� _., , '�Vff,-',K�;." " - .,� A .--�1.1��"-.-"'�.-'�!,�,-�--��-,�, ,, M g -�"','yN - j ,� .- ;'-s-C � ,, " � ,,_,�,,;. 44nr, rk-�5.��,�R 0§�4f �Vf`gf I �� .., i-.,.'�,,,,.,. �,,.",,I,r �s� -$,;�-*r �-,� ,. 11, ",,"l, ". 7-1g,jt# agg-j-p- � � p4 g �L'gv,,, � ggm-q- ,�,.-� "--i'l�z-,�i��',.-'F'��.:�""�,�,��� ��.', i-_,'.� �+' - , . " - 6 '... , , (i ; 5WEET REFEREWLE - -1 _j /��MLLETIN �. � I . fi",. :�." �,... �, ..- '.. &M� 'TA6 OBIONATION I I .,i, .,.,� 1.1,1i�"?, i", , - . ��tm . 'it �. �. , ` �,v � ", -, -,__,",��,,�'(,, f.,��,,----p - , �; -�-.-,.', � �k , M, I . _�,. _, , , " I , iM , � , " - � . - x- 111-11 III- - 1, - - ." � , , , T I "A , � .�11 , � I I I �,�.i.+S �k , 'M I�R , W - 7,_ U., y .�, _. � ,�� � � � I , , .. � , - , ,�, ,- � - ,',� , - . . , . .. --+1,-1'.--, 1�. 1'. 0 , -a , ,,,, T ."', T.""? . ..... m'.g % ..,1 _11 1, _+'1i191, -1,P .1 :A!112� ��MfR I � : - A_--6, MA , . imigg �--- -, '. �,�,�� ,'p,."�§,�� � ._1 1, , . �, - %'_� - - .. 1� " ., �, �� ��, . . . � - . - ", , ___ � V,.-."",.-,.+�,,�".,.,.""..- , . I ,!:t . 'i`� 'm , 1. ;Ri-sn .�j �.--� �, . 1, . , �� �"" ,i,g 11 ;.��, I " , . 'i'� ", ... MiNaMMOMMM MWRWU� .'_ J'�mg,� ., ,.'i � f& M- . 1..�Z,��,,,�n_z��,�,, �.,% -� OW, COVER SWEET Appavom - , , , P, ,_ , , � 0,�`�� ,,,,,�L,�.";,��,,--,,�,:,,.,�tF �0 I I . , "-y , ,_",q_ . �� "I ,% 11 - ,� I " -, -- -r '� ":�. , I z *_ 11\ W-� � . _jg,�q ,�� �4T,"'-.�,�,pl � . , .."1211" I 1 15,�'- 3_1+ �,, 'IT - I! - " -- -..-.-. , , - lv.,,�'g-� . Z 0= , , . 0 , � � -_ � , .�, , , 'm , W13ER I I F - ,:--,- "� -, - yjf!,",�g�,,��.-,,�', I � 4i!,.�� _,fM �, ,, - " �� , L LINE, COMRO-1 " � ., 11 , Z 3 � LEVE .,5 .21m . M , , ,. - - .- A ... 11 ,,_-,,,, - ,�, - , - � ,,, I . I 011 :: ,�� . .. ... �,� - - I .,�,,, � I g� .i� , - �, " . ,O M- .� i - ".."'It, .,. - .4,0, �, , . ,j -i . ,g &.e�.Q';.,�, - 0 0 ,--- -iii_�,',,t����.�. ,;.a�,v 1.11till-I ;,M: I '� ", �',� '. , -, -l"', � - -, . __+N.Z�_ ," . . . � . - ".2, ��,� ___, _ �� - , / %,vf_,,�. 1, � 1. fi, _r - . N A I �_, ,g ., � �,.�\' ��. �,� �&ejk�.,,;�c ,-,',, ��,, _;,� �N�; , .. - � M F11 ..� �! r - ";. O',�".�� �4 , . W . ..". W . � It, r.,�.��.'�, _ . , ___ NI., ��.�� ?11 � ..� . . � - gn��,,, ��?�� .,�.?..-,..,�,,-��.-.,�,,'�,.4�,�.'�,�i',,�,.**,-,-,�, '_e,_� . �:,�,;M,tzqf_ -�,-,�;'i.l � .�, I , . - \g.. '�.,, , 1. �g,�,4�� w. :,. . ,.."5,�!��. � I , 1 I - - I .., �W� :, � - -- I � IW7;5E(,TLON ..... - I . , � __ ,." , � , ..,. , � __.4 ,� 1. . " �:� � _� g- 11 .- � _ _1� I 1- I - :, ,,�,,. I . � � t: BURD - --,"I". " _'_ . ,� , I it - - ._ . - . �. I I �. - %Rn: ,� � . I . .§i .: _1a I , . . , _ , , - 6 �:�,� 74 � , ;.� K" '1' NUMBER C� -' TA& 101" - ., .1 : P , .��:M$�� ,� -,.,L,,7 I - POI R j�� . .. I � I ��,?�LO - I 11 " ,.? 11 I : , . � . .1 I I " ." .:,,, I . : . . . .. , ".,. 11;�2";,. _ - nX. . I I I I 1 1-71. � . . . ? . A- , �,�', I.` I 'Sheet no. I . I A�� Al�tl __1__1 I ....... 4 _r_ L = 0�_ —6.6 . I � � � � . I 1� I - ,� . . ,:i: � y ? I , r" REVKjION -51A�FAGE MW 1. '. . � . � N . .. - ". - � % I . . � -, - , � I M k, BUBBLE � .1 I - . "I . 11 I I I + I � " A . I ''I - I . , � . � t: , 11 .. .. - . . . n ' I I , �' - - 5HEET REFEREW,E � ? ) �_,) #�' . 5TAIVARD . � I . I , 1\ �_ S_ -.11 I I I - I � . I I � I -ENTER I I I e , . " I I M)MBER . MIRROR RECE55E-19 , � .1 ..3EMINCff,1044E�C I I I 1. goo .1 i.:,� , . , 4 1 , I I � �, � ,; '' ,� I I � . . '_ , ' I 11 .5ANIFFORD, ft � ,� I I , ,';11 I I � . I . I I - _1 .11 I I I 1 —77-7 1 1 __ FNI � r, I 1-1 1, , j I lk I —7 1". � � — .� 1 7-71" . I T_�� ' 40 C a - - J-1 I - I , _ q'I"..- jJ11 . f I I I I I ,z/ , ,, *' , , �' I 11 � i , I 1, a . I _� /____5TANPAR0 I NOIZTfl I _ . I NORT�f I . I . I � � I I ,� , 0 s'':'_' I — . r -A, I 1: V: '' �] , �' " I 0 I I 1. I.,- L I .1-1., . I . ,+, "t __ I �� � I - . = � __,_____ 1. —._.'=P_-- ------A L I - 1-111 I �` I . - I ., . I L 11 � I I I - ". �. L I L I I I � I'll, t�.�;:,"_ � "�! ''.1 -_11 i'i " , L I � 1. -1 ,, ,�. L ILI - I - �_ � I . I � " . I I I 1.11 I L ,."I ; I .I �,� , - I'-"., I I . �'!�:.: I I - � � I + �L � � �:,,,:I�i'111 - . 1. I . . 11 ;',�:,, V'!!b�_.� I I . I �, I I _' , I ,� . 1`1 I 11--l"'111 - � I . . 11. � I — I; . �, �, I 1, L'' ,� '.11 � .C� *,��i_- . � 1 I., 11 'Ll . L ,, , I . � p .., I ' -1 � ' ' � I., -L �, I, F . L I + I I . � I I �, '.� 'L � 1. I . I I '' - " - '' - � ;1 , L-, � �� . I �,;_, I I . .1 I .1 � . L . . . ,I r L, — . -L. � L I "" �. I �, 1, ." 1�, ,,' I �11, ,�,�,�11.1,11,�,,L,."�,"i%�'�' . I I . I � I . I , L � I . , �` - . ' : �,�r.� - I .1 L;.. 11�� 1. :��_ ".. , ��', -i`t�� I I . I I r .1 :r '�, I I I . . -L 1; .�,e _�i - I I . I _ ,;�' _ I . . I � I . I I - . . . 11 I . I -.1 .11 1. ,� � ' � ;:�";�. 11 _ _; . , 1, -, ,,, NOTEt A. 6.C. SHALL BID 50% OF THE PAINT INDICATED ON THE DECOR PLAN TO BE AN ACCENT COLOR THAT 15 TO BE DETERMINED. B. G.G. TO FILL AND PAINT ALL NAIL HOLES. ALL FITTING ROOM MIRRORS, DOOR FRAMES AND HARDWARE, WALL BASES, PODIUMS, GLAZING CHANNELS, ETC. ARE TO BE CAULKED TI6HT TO ADJACENT 5URFAGE5 WITH PAINTABLE CAULK, DOW OR EOUAL AND PAINTED TO MATCH ADJACENT SURFACE5. PAINT BENJAMIN MOORE PAINT ONLY - NO 5U135TIlUTION5 NOTES: APPLICATION / INSTALLATION: WALL5: LO SHEEN EC -6 HELL LATEX DOORS 4 TRIM: 5EMI-GLO55 ALKYD CEILING: FLAT LATEX INSTALLATION: GYPSUM BOARD TO RECEIVE LATEX PAINT TO BE PRIMED WITH ONE GOAT OF VINYL PLA5TIG SEALER PRIOR TO REGEIVIN6 TWO GOATS OF PAINT. WOOD TRIM AND 5LATWALL TO RECEIVE ALKYD OR ENAMEL PAINT TO BE PRIMED WITH ONE GOAT OF ENAMEL UNDER(OATER PRIOR TO RECEIVING TWO GOAT5 OF PAINT. PAINT ALL WIRES, RETURN AIR GRILLES, AND SUPPLY AIR GRILLES TO MATCH ADJACENT CEILING AREAS P-1 BENJAMIN MOORE (NO 5UB5TITUTION5) MANUFACTURER: BENJAMIN MOORE (NO 5UB5TITUTION5) REPRESENTATIVE: 888.263.666-1 STYLE: OFF WHI > E COLLECTION NUMBER: OC -65 COLOR: CHANTILLY LACE FINISH: FLAT AREA: CEILING DOLOR FOR ALL DEPARTMENTS NOTE: REFER TO DRAWIN65 FOR EXACT P-1 LOCATIONS P-2 888 263 6661 MANUFACTURER: BENJAMIN MOORE (10 5)'05TT'l nON5) REPRESENTATIVE: 888263.6661 STYLE: OFF WHITE COLLECTION NUMBER: 06495 COLOR: CHANTILLY LACE FINISH: EGGSHELL AREA: LADIES, MENS, KIDS, AND BACK OF HOUSE NOTE: REFER TO DRAWINGS FOR EXACT REPRESENTATIVE: LOCATIONS P-3 2132-10 MANUFACTURER: BENJAMIN MOORE (NO 5UB5TITUTION5) REPRE5ENTAT I VE: 888.263.6667 STYLE: REFER TO DRAWIN65 NUMBER: 2134-30 COLOR: IRON MOUNTAIN FINISH: FLAT AREA: FLOATING CEILINGS (NOTED ON DRAWIN65) NOTE: REFER TO DRAWIN65 FOR EXACT NUMBER: LOCATIONS =2 MANUFACTURER: BENJAMIN MOORE (NO 5UB5TITUTION5) REPRESENTATIVE: 888.263.6661 5TYLE: 2028-10 NUMBER: 2134-30 COLOR: IRON MOUNTAIN FINISH: EC765HELL AREA: LADIES, MENS, "YOUNG DEPARTMENT, ARID NOTE: GEILIN55 NOTE: REFER TO DRAWIN65 FOR EXACT P-1 LO( ATIOR5 P-5 888 263 6661 MANUFACTURER: BENJAMIN MOORE (NO 5UB5TITUT10N5) REPRESENTATIVE: 888.263.6661 STYLE: 2028-10 NUMBER: 2146-20 COLOR: FOREST M055 FIN15H: EGGSHELL AREA: BACK OF Ti0U5E NOTE: REFER TO DRAWIN65 FOR EXACT P-8 LOGATI ON5 IW% MANUFACTURER: BENJAMIN MOORE (NO 505TIMON5) REPRESENTATIVE: 888.263.bbbl STYLE: 2028-10 NUMBER: 2134-40 COLOR: WHALE GREY FINISH: E665HELL AREA: REFER TO DRM, N65 NOTE: REFER,TO:DRAWEN65 FOR EXACT P-8 LOCATI ON5 P-1 BENJAMIN MOORE (NO 5067T TUfI0N5) MANUFACTURER: BENJAMINMOORE (NO 51)135TMMONS) REPRESENTATIVE: 8882b3.b61 NUMBER: 2028-10 DOLOR: IGUANA GREEN FINISH: EGGSHELL AREA: REFER TO DRAWIN65 NOTE: INSTALL AND MAINTAIN PER FIRE RATING: MANUFAGTUREIR5 REGOMMENDATtON5 P-8 REFER TO ORA"rSIN65 FOR DETAIL5 MANUFA( TURER: BENJAMIN MOORE (NO 5067T TUfI0N5) REPRESENTATIVE. 888 263 6661 NUMBER 2015 -JO DOLOR::OUTRtrGE 6. Vk5_1'. FINISH: E665HELL AREA: REFER TO DRAWIN55 NOTE: IN5TALL AND MAINTAIN PER STYLE: MANUFAGIIURER'5 REGOMMENDATI0N5 P -q TEST - 0.45 WATT5/50 GM PASSES MANUFACTURER: BENJAMIN MOORE (N0 5IIIB5TITUTLON5) REPRESENTATIVE: 888.263.6661 NUMBER: 2132-10 COLOR: BLACK FINISH: EGGSHELL AREA: REFER TO DRAWIN65 NOTE: INSTALL AND MAINTAIN PER REPRESENTATIVE: MANUFAGTURER'5 RECOMMENDATIONS P-10 24"x24" CONCRETE COMPOSITION TILE MANUFA(,TURER: BENJAMIN MOORE (NO E.JE "T17UT1,O116) REPRESENTATIVE: 888.263.bobl NUMBER: 2003-10 COLOR: MILLION DOLLAR RED FINISH: EGGSHELL AREA: REFER TO DRAWIN65 NOTE: INSTALL AND MAINTAIN FIER - MANUFACTURER'S RECOMMEI+lDATIONS P-11 REFER TO 6-2 ON THI5 9IEET FOR MANUFACTURER: BENJAMIN MOORE (NO 905TITIUTlON5) REPRESENTATIVE: 888.2(q35bbT NUMBER: 2132-10 DOLOR: BLACK FINISH: FLAT AREA: REFER TO DRA),0465 NOTE: INSTALL AND MAINTAIN PER MANUFAGTURER5 RECOMMENDATIONS MANUFACTURER: FORMICA REPRESENTATIVE: 800.361.6492 NUMBER: b5b DOLOR: RIVER PO?;K MOSAIC FIN15H: SATIN 5IZE: 30"x145" THIGKNE55: 1/2" THICK FIRE RATING: - AREA: REFER TO ORA"rSIN65 FOR DETAIL5 NOTE: INSTALL AND MAINTAIN PER REPRESENTATIVE: MANUFACTURR>ER5 REGOMMENDATION5 5TOREFRONT TILE BRUSHWORKPREMIUM V GT LM -1 102 MANUFACTURER: LA BREA REPRESENTATIVE: STONE 50URGE - THIGKNE55: PAUL CAR160, 2I2.MrI 6400 STYLE: LA BREA BLACK NUMBER: TEST - 0.45 WATT5/50 GM PASSES COLOR: GREY SIZE: 2"x24', 4"04', AND 6'x24' THIGKNE55: APPROXIMATELY 1/2" FINISHED: LIME5TONE HONED FIN15H AREA: 5TORFEFROINT NOTE: PROVIDED S`( OWWP., INSTALLED BY 5L. FLOORI W-9 NOTE: INSTALLATION / MAINTENANCE: INSTALL AND MAINTAIN PER MANUFACTURER AND INDUSTRY STANDARDS, U51N6 MANUFACTURER RECOMMENDED MATERIALS. REFER TO ATTACHED INFORMATION. VCT -1 MANUFACTURER: ARMSTRONG WORLD INDUSTRIES REPRESENTATIVE: JEFF HALL, 500.35b.g3Ol x8830 STYLE: IMPERIAL TEXTURE NUMBER: 51801 COLOR: SHADOW BLUE 5IZE: 12"x12" THIGKNE55: 118" AREA: B.O.H. ONLY VGT-2 800-443-8380 MANUFACTURER: MANNINGTON COMMERCIAL REPRESENTATIVE: 800.241.2262 STYLE: BRUSHWORKPREMIUM V GT NUMBER: 102 COLOR: GRANITO 5IZE: 12"x12" THIGKNE55: I/8' THICK FIRE RATINC75: A5TM E645 FLOORING RADIAN PANEL PT -1 TEST - 0.45 WATT5/50 GM PASSES MAM)FAGTURER: GLA55 1 N.13.5. SMOKE CHAMBER TEST REPRESENTATIVE: ASTM E662 <450 PA55E5 AREA: REFER TO DRAWIN65 FOR DETAILS NOTE: INSTALL AND MAINTAIN6 PER NUMBER: MANUFACTURER'5 RE( OMMENE)ATION5 CON -I 6R1GIO 45PMTE MANUFACTURER: 8"x8" REPRESENTATIVE: 5/Ib' 5IZE: 24"x24" CONCRETE COMPOSITION TILE THIGKNE55: 518" COLOR: 1JI�PS A"t iTr"i" i "r'1. AREA: SALES FLOOR NOTE: FURNISHED BY OWNER, INSTALLED REPRESENTATIVE: BY 6.G. IN STACKED PATTERN. NOTE: G.G. SHALL USE 1/4" NOTCH TROWEL MANUFACTURER: FOR THIS APPLICATION. NOTE: USE NO SEALER ON FLOORING. t0T.F: REFER TO 6-2 ON THI5 9IEET FOR 517E: GROUT 5PEGIFIGATION AND COLOR. NOTE: 6.( . SHALL INSTALL FRACTURE FIN64t- MEMBRANE AND CONTROL JOINTS. A-WHIT6GTURAL 55-1 MANUFACTURER: REPRE5ENTATIVE: STYLE: PREFINISHED 5TAINLE55 STEEL NUMBER-- UMBER:FINISH: JANICE BAYS, 817.216.1816 x8112 FINISH: 04 SATIN FIN15H THIGKNE55: .063/.OqO AREA: 5TOREFRONT(5) NOTE: 5QUARE F -I WHITE MANUFACTURER: AYfRY 6RAP;416S REPRESENTATIVE: 800-443-8380 STYLE: LIGHT CONTROL NUMBER: A2851-5 FIN15H: BLAGK/BLAGKOUT THIGKNE55: JUNE SEARS, 800.b88.3g1i6 AREA: EXTERIOR GLAZING. REFER TO NUMBER: DRAWIN65 FOR EXACT LOCATIONS. NOTE: GDI3 GRI610 4'C KELAIN TILE 4"x8" PT -1 FIN15H MAM)FAGTURER: DALTILE REPRESENTATIVE: JUNE SEARS, 800.688.3gcib STYLE: PORGEAL TO COLOR BODY PTWB-2 PORCELAIN - FLOOR NUMBER: GD40 COLOR: 6R1GIO 45PMTE SIZE: 8"x8" THIGKNE55: 5/Ib' FINISH: UNPOLISHED AREA: TOILET ROOM FLOOR NOTE - 1JI�PS A"t iTr"i" i "r'1. K -9 MATTE MANUFAGTURER: DALTILE REPRESENTATIVE: JUNE SEARS, 800.688.3ggb 5TYLE: PORGEAL TO COLOR BODY MANUFACTURER: PORCELAIN - WALL NRIDER- GDI3 COLOR GRI610 517E: 8"x8" THICK: 5/16' FIN64t- UNPOL15HED AREA, TOILET ROOM WALL YOM 9 HISH 5TREW5�1tH 2 56 Er, 2n KR F €Z_T_ k4OOD BLOGKTN6 A6 - FLFQUIRE] LINE OF DISPLAY PLATFORM E4ELfiR REFER TO 51E T5 A-1.1, A-4.1, AND A-4_2 +IENC SIDE FOR MORE IWORMATION 4 D0OP_ F FER. TO DOOR 56+EDtI ON 3 f`HI5 5HEET FOR A_0 MORE {POIMAT1 6LAZINI6 AND 6LA iNb MILL BELOW. REFER -TO 5TOREFRONT 51FET5 FOR MORE y A-0.2 SCALE: 3" lATLM -SIDEIM11 VMI�1� AGT-I MANUFACTURER: ARMSTRONG CEILINGS REPRESENTATIVE: JANICE BAYS, 817.216.1816 x8112 SIZE: 24"x48"x5/8" STYLE: DUNE NUMBER: 1113 EDGE: 5QUARE COLOR: WHITE AREA: REFER TO DRAWIN65 GRID: REFER TO GLG-I ON THIS SHEET WALL BA51E FOR GRID/505PEN51ON SYSTEM MANUFACTURER: ARM5TRON6 GEILIN65 REPRESENTATIVE: JANICE BAYS, 811.216.7816 x8112 STYLE: PRELUDE NUMBER: - COLOR: WHITE 5IZE: 15/16" WIDE FIRE RATINGS: - AREA: REFER TO DRAWIN65 NOTE: - WALL BA51E MANUFAGTURER'5 RECOMMENDATIONS PTWB- I JUNE 5EAR5, 800.688.3ggb MANUFACTURER: DALTILE REPRESENTATIVE: JUNE SEARS, 800.b88.3g1i6 STYLE: PORGELATO SURFACE BULL N05E NUMBER: 5448q COLOR: GDI3 GRI610 SIZE: 4"x8" THIGKNE55: FIN15H FINISH: MATTE AREA: TOILET ROOMS NOTE: -\ PTWB-2 STOREFRONT DISPLAY MANUFACTURER: DALTILE REPRESENTATIVE: JUNE SEARS, 800.688.3gg6 STYLE: PORGELATO 5URFAGE COVE BA5E NUMBER: 5368gT COLOR: GD13 6RI610 5IZE: 6"x8" THIGKNE55: 1JI�PS A"t iTr"i" i "r'1. FINISH: MATTE AREA: TOILET ROOMS NOTE: _ VWB-1 MANUFACTURER: JOHN50NITE REPRESENTATIVE: 800.8gq.8q 16 STYLE: 4" WALL BASE W/ PREFORMED �- GORNER5 NUMBER: #21 COLOR: PLATINUM FIRE RATINGS: A5TM E84/NFPA 255 (STEINER TUNNEL TEST) - GLASS G A5TM Eb48/NFPA 253 (CRITICAL RADIANT FLUX) - GLA55 I A5TM E662/NFPA 258 (SMOKE DENSITY) - 450 OR,LE55 AREA: B.O.H. ONLY NOTE: GLASS VI, -0-2 GLA5. MANUFACTURER: JOHN50NITE REPRESENTATIVE: 800.8gq.8q 16 STYLE: 4" WALL BASE W/ PREFORMED CORNERS NUMBER: #38 COLOR: PEWTER FIRE RATINGS: A5TM E84/NFPA 255 (STEINER TUNNEL TEST) - CLASS G A5TM E648/NFPA 253 (CRITICAL 1�4 RADIANT FLUX) - GLA55 1 I A5TM E662/NFPA 258 (SMOKE METAL DENSITY) - 450 OR LE55 AREA: B.O.H. ONLY TO BE U5E1) WITH WA VCT -2 ONLY. REFER TO DRAWIN65 I FOR LOGATiON5. NOTE: INSTALL AND MAINTAIN PER MANUFAGTURER5 RECOMMENDATIONS WB -1 MANUFACTURER: - REPRESENTATIVE: - FiNi5H: MDF NUMBER: - COLOR: - FIN15H: GLA5. AREA: SALES FLOOR NOTE: PROVIDED BY OWNER, IN5TALLED BY 12 66. NOTE: PREFINISHED. 6.G. TO FILL AND PAINT ALL NAIL HOLE5. G.G. SHALL CAULK WALL BASE TIGHT TO ADJACENT SURFACES WITH PAINTABLE CAULK, DOW OR EQUAL, AND PAINT TO MATCH ADJACENT ISa6 5URFA6E5 IN ADDITION. 6.6. 5MLL b CAULK BASE TIGHT TO TILE FLOOR GLA55 SURFACES. " REFER TO 5HEE75 A-1-1, A-1-2, A-0, A-1.4, A-1.5, ANDA 5_I FOR WALL GON5TRUCTION TYPE, :I I/4' GYP_ BID. IN T11415 AREA AT SCREW LOGATIO�6, 5ELECTIVELY R_FMOVE 6Yfl BD., AND INSTALL 5/6' 7 FLAT WA5HER5, STACKED TO PREVENT GRI _)flIN5 OF 6YP: BD. 114' GYP: BD. IN TH15 AREA iso-RVDTIQr�+T�5. 'TSI 70 DOOR 5GHEUU ON THIS 5HEE T FOR MORE 4WFO€ MT10K i UA r r Ir^ r i2 • �•MW I r• / , dr-gls-d5ply _ LAMINATE L -I FOR: MANUFACTURER: NEVAMAR REPRESENTATIVE: 800.638.4380 NUMBER: 51032T COLOR: BONE WHITE FINISH: TEXTURED FIRE RATING: TOILET ROOMS ONLY AREA: REFER TO DRAWINGS FOR DETAILS NOTE: INSTALL AND MAINTAIN PER MANUFACTURER: MANUFAGTURER'5 RECOMMENDATIONS G -I FOR: MANUFACTURER: MAPEI - EPDXY REPRESENTATIVE: JUNE SEARS, 800.688.3ggb NUMBER: Oq COLOR: GRAY 5IZE: SMALLEST GROUT JOINT POSSIBLE AREA: TOILET ROOMS ONLY NOTE: POWDERED / NON-5AND GROUT 6-2 JHARDWARE MANUFACTURER: MAPEI - EPDXY REPRE5ENTATIVE: JUNE 5EAR5, 800.688.3ggb NUMBER: 02 COLOR: PEWTER 5IZE: SMALLEST GROUT JOINT POSSIBLE AREA: 5ALE5 FLOOR NOTE: USE WITH GON-I ONLY, EPDXY GROUT NOTE: POWDERED / NDN-5AND GROUT VERIFY WITH FLOOR PLAN 11 AL STUD AND GYP. BD, WALL 15TRU6TION. REFER TO SHEETS I, A-12, A-1.3, A-1.4, A-1.5 AND .I FOR WALL TYPE5. NON COMB. F.R.T. WOOD BLOGKIN6. F.R.T. SHIM LOW METAL DOOR FRAME. F.R.T. 5HIM NON COMB. F.R.T. WOOD BLOC'."'ING. AL STUD AND GYP. BD. WALL 15TRUGTION. REFER TO SHEETS A-I.I, 2, A-1.3, A-1.4, A-1.5, AND A -5J FOR L TYPES. 140U_uW METAL JAMI /'BEAD DETAIL. SCALE: 3" = I'-0" REFER TO SHEETS A-I.I, A-1.2, A-13, A-1.4, A-1.5 AND A-5.2 GYP. BD. ON METAL STUD WALL CONSTRUCTION, ALL BY 6.6. REFER TO 5HEET5 A-I.I, A-1.2, A-1.3, A-1.4, A -i 5, A-5.1 AND A-5.2 FOR MORE INFORMATION (TYP). 2x NON COMB. F.R.T. NAILER. (TYP.) 1/4" F.R.T. 50M5 A5 REQUIRED. (TYP) ROUGH OPENING 51ZE5: STANDARD FITTING ROOM ROUGH OPENING 30" WIDE 85" HIGH ADA FITTING ROOM ROUGH OPENING 36" WIDE 85" HIGH t SCALE: 3" = V-0" STORE FOR: DOOR 56HEDULE INTERIOR - DOOR MALL ❑ design dev. OPEN TD 51DE ADJACENT WAL1_ BEYOND 03-16.09 ❑ construction -' 4° HOLD V OFFSET PIVOT 91 landlord final JHARDWARE HINGE. (TVP) REMARKS ' T.STT Fifirly: ' rr C' REFER TD TO 5TOREFRONT 5HEET5 FOR 3/8' TEMPERED 5AFElY-� MORE INFORMATION. 6LA55 (ALTERNATE: ON TH151I"f 1/4" 3/8' PLEXI).MAX. SIZE TYPE FINISH NATERIAL FIN15H BOTTOM MOUNTED PATCH 51 MATERIAL i HARDWARE, Wl LOCK ON GROUP -\ SALES AREA SIDE, AND STOREFRONT DISPLAY 6 THUMB -TURN ON DISPLAY �, �' � PLATFORM SIDE.71 ' 4 / A-0.2 12 3/8)„ t"EMPEREP SAFETY GLA55. 2'-0" x 4'-0" x 3/8" 1JI�PS A"t iTr"i" i "r'1. '\-AD_b86f IRT 5LAZIN5 BAS. DOOR DISPLAY VW'1NWW ION dr-fIrrgrm At -!o_2 SCALE: 1/2" = 1'-0" dr-gls-dsply-elev Ee DOOR TYPES 0 i --L- --., 1 - - -7'_ - - - -- - r r - -- ' t z 0 I 1 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright (c 2009 KEN NI FI E SC AIA All rights reserved Certification: 211., r a� 606 o � Ole 4 Consultants: RETAIL DESIGN CONSULTANT r JGA INC ' 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Cwrslnd tl 20' �cn. 1- ti, ,• «-.d www.igo.corn JGA Prj : 1-209--057 DRAWINGS ISSUED FOR: DOOR 56HEDULE - DOOR 02.0q.N ❑ design dev. FRAME ❑ bidding DETAILS 9 permits 03-16.09 ❑ construction -' IM landlord prelim. 02.0q.0q 91 landlord final JHARDWARE REVISIONS: REMARKS DOOR NO. SIZE TYPE FINISH NATERIAL FIN15H TYPE MATERIAL HEAD JAMB GROUP 1�1 STOREFRONT DISPLAY 6 GLASS GLASS GLA5. - GLASS 4 / A-0.2 4 / A-0.2 12 3/8)„ t"EMPEREP SAFETY GLA55. 2'-0" x 4'-0" x 3/8" _ 1:a2 STOREFRONT DISPLAY b GLA55 GLA55 CLAS. �- GLASS 4 / A-0.2 4 / A-0 2 12 3/8" TEMPERED SAFETY GLASS. 2'-O" x 4'-0" x 3/8" _ - )ii)STOREFRONT DISPLAY 6 GLASS GLAS5 GLA5. - GLA55 4 / A-0.2 4 / A-0.2 12 3/8" TEMPERED SAFETY GLASS. 3'-0" x 4'-0" x 3/8" 1�4 STOREFRONT GRILLE I GLEAR_ METAL N/A - STEEL WA N/A I MOTORIZED GRILLE. G.C: TO APPLY "THIS POOR TO REMAIN OPEN PURINO I -P -q 3/4" x 12'-0" ANODIZED �---� --- -� DJ51NE55 HOURS" ADJ. TO POOR AT LOCATION DIRECTED 5Y INSPECTOR. STOREFRONT5PL SPL STOREFRONT DIAY b GLASS r T GLASS GLA5. -- GLA55 4 / A-0.2 4 / A-0.2 12 3/8" TEMPERED SAFETY GLA55. 4'-0x 3'-0" x ISa6 STOREFRONT DISPLAY3/8" b GLA55 GLA55 CLAS. - GLA55 4 / A-0.2 4 / A-02 12 TEMPERED SAFETY GLASS. 2'-0" x 4'-0" x 3/8" 4 / A-0.2 Imo, STOREFRONT DISPLAY 6 GLA55 GLASS CLAS. - GLA55 4 / A-0.2 12 3/9;," TEMPEREP SAFETY GLA55. 2'-O" x 4'-0" x 3/&" - IiS H.G. FITTING Rdbm N/A 5 { r-f�TltlS !C? WOOD P.F. - P.F. 2 / A-0.2 5 P.P. = PRE -FINISHED. U" ><'7'-O" x 1 3/4" l�9 - III FI rTING ROOF 15 q PRE-FINISWP HOOP P.F. - P.F. N/A 2 / A-02 5 P.F. =PRL -FINISHED, 2'-6" x 5'-6" x 1 3/4" Ili - II6 FITTING ROOMS Q PRE-FINI5HD WOOF P.F. - P.F. N/A 2 / A-0,2 5 P.F. = PRE -FINISHED. 2'-6" x 5'-6" x 1 3/4" II9 5 H.G. FITTING ROOM PRE-FINISHD WOOD P.F. - P.F. N/A 2 / A-02 5 P.F. = PRE -FINISHED. 3'-0" x -f'-O" x 1 3/4" _ ____-- _ 12x0 5AGK OF HOUSE DOOR I / A-0.2 I / A -0.2I HOUR RATED GONSTRUGTION. 2 PTP. TO MATCH HOLLOW P -X - METAL 3'-0" x -'-O" x 1 3/4" ADJ. WALL I-IETAL METAL - 6 ---121 OMEN'S TOILET R. WM 2 PTO. TO MATCH HOLLOW F' -X ----_u I / A-0.2 I / A-0.2 3'-0" x 1'-0" x 13/4" ADJ. WALL METAL 122 MEN'S TOILET ROOM HOLLOW P -X 2 PTD. TO MATGH - METAL I / A-0.2 I / A-0.2 b 3 -O" x 7'-O" x 1 3/4" ADJ. WALL METAL I / A-0.2 12'3 STOCKROOM 2 PTD. TO MATCH HOLLOWI F'_X - METAL I / A-0.2 2 HOUR RATED CONSTRUCTION. (2) 3'-O"x7'-O"x1 3/4" 3 ADJ. HALL METAL HOLLOW20" G -C. TO VERIFY WITH OWNER FOR KICK PLATES NEEDED. ` 124 DECO ROOM PrP. TO MATCH P -X - METAL I/ A -O.2 I/ A-0.2 3 x 30" WINDOW. LITE ONLY. 3'-O" x �i'-U" x 13/4" ADJ. WALL METAL - 2 PTD. TO MATCH - METAL I/ A-0.2 I/ A-0.2 4 DOOR TO BE UNDERCUT. 12� ADMIN. OFFICE HOLLOW P -X 3'-0" x -P-O" x 1 3/4" ADJ. WALL METAL - - I2(a LAN. ROOM 7 PTD. TO MATCH HOLLOW P -X - METAL I / A-0.2 I / A-0.2 e> I HOUR RATED CONSTRUCTION. 3,-O" x i' -O" x 13/4" JANITOR'S CLOSET -- 2 ADJ. WALL METAL - 12"1 PTD. TO MATCH HOLLOW P -X - METAL I/ A-0 2 I/ A-0.2 q 3'-0" x 7'-O" x 1 3/4" ADJ. WALL METAL I / A-0.2 I / A-0.2 _ 128 MANAGER'S OFFICE 3 PTD. TO MATCH HOLLOW F'_X - METAL 10 20" x 30" WINDOW. LITE ONLY. 3'-0" x -1'-0" x 1 3/4" ADJ. WALL METAL _ 129 ELECTRICAL ROOM 2 PTD. TO MATCH ----- HOLLOW P -X - METAL I/ A-0.2 I/ A-0.2 B I HOUR RATED CONSTRUCTION. 3'-0" x -P-O" x 1 3/4" APJ. WALL METAL 13m EGRESS POOR 2 PTD. TO MATCH HOLLOW P -X - METAL I/ A-0.2 I/ A-0.2 11 I HOUR RATED CONSTRUCTION. 3'-6" x �'-O' x 13/4" ADJ. WALL METAL - NOTE: KEY ALL DOORS ALIKE. PRIOR TO CONSTRUCTION CONTRACTOR SHALL VERIFY WITH HARDWARE SUPPLIER AND ARCHITECTURAL CONSULTANT THAT ALL DOOR HARDWARE MEETS ALL STATE AND LOCAL IDES AND ORDINANCE5. NOTIFY OWNER OF ANY DI5GREPANGIE5. NOTE: ALL LOCKING DEVICES AND PANIC HARDWARE SHALL BE VERIFIED BY THE CITY. NOTE: ALL DOORS AND HARDWARE SHALL CONFORM TO CURRENT APPLICABLE 5TANDARD5 FOR HANDICAPPED ACGE5516ILITY. NOTE: EXIT DOOR5 SHALL BE OF A SIZE A5 TO PERMIT THE INSTALLATION OF A DOOR NOT LE55 THAN THREE FEET WIDE OR 68" HIGH. NO DOOR LEAF SHALL EXCEED 4'-0". NOTE: DOORS SHALL BE OPENABLE FROM THE INSIDE Y4ITHOUT THE USE OF A KEY OR ANY 5PEGIAL KNOVILEDGE. NOTE: ALL EGRE55 DOORS SHALL REQUIRE NO 5PE61AL EFFORT TO OPERATE AND OPEN. NOTE: ALL LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND 141.1101 ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DE516NED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRA5P THE OPENING HARDIeIARE. LOCKED EXIT DOORS SHALL OPERATE A5 ABOVE IN EGRE55 DIRECTION. NOTE: HAND -ACTIVATED 0 ' r-OPEWNc✓Ami zf4"-AB•O)A "ft 8,002 NOTE, MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED FIVE (5) POUNDS FOR EXTERIOR DOOR5 AND INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE: CENTER PLANE OF 5LIDIN6 OR FOLDING DOORS. GOMPEN5ATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE 5TANOARD5. WHEN FIRE DOOR5 ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE MAXIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED FIFTEEN (15) POUNDS, A !!� 6ROUP-1 6ROUP-6 GROUP -IO (3) CYLINDER - BEST - IE--74-C,4-RP3 I-112 HINGE`S - 5TANI rY - FB[3rIq - US 2b D I-1/2 HIN6E5 - STANLEY - FBBI1q - U5 26 D INTERIOR THUMBTURN - US 2b D (1) P05H PLATE - IVES - 8200-U526D-4x16 (1) PASSAGE SET - BEST - 13KG-8K-N-152 - U5261) KEY 5WIT6H MOUNTED ® 24" AF.F. (REFER To (1) PULL WITH PLATE - IVE5 - 8103-8-1,15261) FULL WITH (I) CLOSER - LGN - 4011H - AL INSTALLED ON STOREFRONT DETAILS FOR LOCATIONS) IVES - 8303-8-U52bD-4x16 PLATE (ADA COMPLIANT) PULL SIDE OF DOOR - HOLD OPEN EMERGENCY PULL TO BE MOUNTED @ 36" AF_F. (1) CLOSER - LGN - 4011H - AL IN5TAr L ED ON PULL SIDE (I) WALL STOP - IVES - W5402GGV - U5261) (REFER TO STOREFRONT DETAILS FOR LOGATION5) OF DOOR - HOLD OPEN (I) FLOOR STOP -IVE5 F513 -U526D GROUP -II GROUP -2 (1) FLOOR STOP R15ER A5 REQUIRED - IVE5 R14 - U526D 2 PAIR HINGES -STANLEY - FBBIlq - US 26 D -NON REMOVABLE PINS - PER DOOR - (1) PANIC DEVICE - ARROW F-430 - CYLINDER DOLLAR FOR 1-112 HIN6E5 - STANLEY - FBBIlq - US 2b D }p-1 8 -PIN INTERCHANGEABLE GORE - U5 26 V - 5IZE TO MATGH DOOR (1) LOGK5ET - BE5T - 13K(/ -SK -R-152 - U5 2b D I-112 HINGES - 5TANLE'( - FBBTlq -- U5 -2b D (1) CLOSER - LGN - 4111 - AL INSTALLED ON PUSH SIDE (1) CLOSER - LGN - 4011 SPRING CU5H - AL - NO (1) PANG DEVIGE - ARROW F-430 - CYLINDER COLLAR FOR OF DOOR - NO HOLD OPEN HOLD -OPEN GL05ER TO BE INSTALLED ON PUL.► SIDE 8 -PIN INTERGHANGEABLE CORE - t6 2b D - 5IZE TO MATCH (I) FLOOR STOP - IVES 1`513 - U526D (2) KICK PLATE - BURN5 - J102 - lb 6A. - 24'H - U5 32 D DOOR - WITH AUDIABLE ALARM WITH V151BLE 516N THAT (1) FLOOR STOP RISER A5 REQUIRED - IVE5 RI4 - 1.526D (1) SET SEALS - PEMKO - 305 GR - AL. READS 'ALARM WILL 50VV WHEN DOOR 15 OPENED" 1) IVES - 1-610-1,15321) TAMPER -PROOF PLATE ON CORRIDOR 51DE (1) SWEEP - PEMKO -•'35 GN x LE6NTH - AL (1) PA55AGE 5ET - BEST-'13KG-8K-N-152 - 0526D - TO (I) LOGK5ET - BEST --13KG-8K-R-152 - U5 26 D (1) FLOOR STOP - IVE5 F50 - U5269 WORK WITH PANIC DEVICE ON PULL 51DE OF DOOR (2) KICK PLATE - BURNS - J102 - I6 GA. - 24"H - U5 32 D (1) FLOOR STOP R15ER A5 -REQUIRE - IVE5 R14 - U526D (1) CLOSER - LGN - 4011 5PRIN& GUSH - AL (1) SET 5EAL5 - PEMKO - 305 GR - AL PER OWNER REGIIJIREMENT (1) TRILOGY LOCK ON PUSH SIDE CLOSER TO BE MOUNTED ON PULL 512E - NNo MOLD OPEN (1) SWEEP - PEMKO - 315 GN x LE6NTH - AL PROVIDED BY OWNER IN5TALLED BY 6L_ (1) FLOOR 'STOP - IVE5 F513 - U52bD (1) DOOR VIEWER - IVES - 100 - 15261) (I)'FIOOR STOP R15ER AS REGUIRFD - IVES, PJ4 - U52bD (1) THRESHOLD - ADA COMPLIANT 6ROUP-3 `(I) SET-5EAL=y - PLIM0 - -3O5-'GR - AL (I) HOUR SELL I-112 HINGES - STANLEY - F5BT7q -16 2b D PEMKO (1) � - "315 ON x LE6NTH - AL G (1) CLOSER MOO) - LN - 401M - AL It6TALLED ON 6ROUP-12 PULL SIDE OF DOOR - HOLD OPEN 6ROUP-8 (3) OFFSET PIVOT HIN6E5 - G.R. LAURENCE # FA044GH, CHROME FINISH. (1) PA55AOE SET -BEST - 13KG-SK-N-I5D - U52bD 1-1/2 HINGES - STANLEY - MOM - U5 26 D (1) PATCH LOCK - GIRL BRUSHED 5TAINLE55 FINISH AMR (2) KICK PLATE -, 5URN5 - J102 - Ib6A - 24"H - US 32 D (1) LOGK5ET - BEST - 13KG-8K-R-15D - US 2b D 5ERIE5 PATCH LOCK BODY - AMR205B5 OR APPROVED EQUAL (1)-GLO5ER - LGN - 4011 SPRING GUSH - AL (1) KEYED CYLINDER AND THUMBTURN - GRL BRUSHED 6ROUP-4 GL05ER TO BE MOUNTED ON PULL .SIDE - NO HOLD OPEN 5TAINLE55 FINISH AMR SERIES - AMR205GTB5 OR APPROVED EQUAL 1-1/2 HINGES - 5TANLEY - FBBI-W - U5 2b D (E) SET SEALS - PEMKO - 305 GR - AL (1) CLOSER - LGN - 4011 - AL INSTALLED ON (1) SWEEP - PEMKO - 315 GN x I FGNTH - AL ALL PANIC, HARDWARE TO BE FIRE / EXIT TYPE HARDWARE. PULL SIDE OF DOOR - NO HOLD OPEN (1) FLOOR 5TOP - IVES F513 - U526D (1) DOOR VIEWER - IVE5 -100 - 52bD (1) FLOOR STOP R15ER A5-R:E0UIRE9 - W:5 R14 - U5269 .DOOR VIEWER IN FIRE RATED DOORS TO BE INTEGRAL PART OF (1) TRILOGY LOCK - PUSH SIDE - PROVIDED DY OWI ER FIRE RATED DOOR A`5EMBLY. _. INSTALLW W 6L. r' -q (1) FLOOR STOP - IVE5 F513 - U521bD 1-1/2 HINvt5 - 5TA.NLEY - FBBIlq - U5.2b D DOOR UNDERCUT SHALL NOT EXCEED 3/8". (I) FLOOR 5TOP R15 -FR A5 REIS)kZrD - IVE5 R14 - U5269 (1) LOGK5ET - BEST - 13KG--8K-R-15D - U5 26 D (1) CLOSER - LGN - 4011H SPRING GUSH - AL FIRE RATED DOORS TO HAVE B-LABEL5. GROUP -5 GL05ER TO BE MOUNTED ON PUI 1510E - HOID OPEN FITTING ROOM HARDWARE PROVIDED BY OWER5 VENDOR (1) KICK PLATE - EURN5 - J102 - I6 6A_ - 24"fl - U5 32 D AND I16TALUP $Y f7.C, -BUNTED ON FUSH SIDE ESTIMATED AT 1-112 PR HIN6E5 AtV LOGKSE T WITH JAMB STRIKE - 62bD (1) WALL STOP - IVs - W54O2G6V - 1.62bD Ee DOOR TYPES 0 i --L- --., 1 - - -7'_ - - - -- - r r - -- ' t z 0 I 1 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright (c 2009 KEN NI FI E SC AIA All rights reserved Certification: 211., r a� 606 o � Ole 4 Consultants: RETAIL DESIGN CONSULTANT r JGA INC ' 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Cwrslnd tl 20' �cn. 1- ti, ,• «-.d www.igo.corn JGA Prj : 1-209--057 DRAWINGS ISSUED FOR: ❑ programming 0 schematic des. 02.0q.N ❑ design dev. ❑ bidding 9 permits 03-16.09 ❑ construction -' IM landlord prelim. 02.0q.0q 91 landlord final 02.27,09 REVISIONS: i' Prj. no. 8-209-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: DECOR FINI5W SPECIFICATIONS AND DOOR SOEDULE Sheet no. r --L DEMOLITION KEY NOTES: DEMOLITION ENERAL NOTES: I]] REMOVE ALL EX15TING DUCTWORK FROKROOF TOP VNIT5 A55QGIATECJ.WITH THE NEH LEA5E AREA. -A. PRIOR TO THE 5TART OF DEMOLITION THE GENERAL CONTRACTOR WILL V151T AND EXAMINE THE 51TE CONDITIONS AND NOTIFY ARCHITECT OF ANY AND ALL 1-21 EXI5TING RATED DEM15IN6 NALL TO.R+1AfK 6.6. Tp. VERIFY,RATIN6 D15GREPANGIE5 THAT MAY AFFECT GON5TRUGTION. DETAILS AT THE 5TART AND 1-31 5EL EGTIVELY DEMO. OF DFM151% HAI I -REFER TO 5HEET5 A -i.1 AND A-5.3 FOR MORE INFORMATION. COMPLETION OF DEMOLITION, B. THE GENERAL GONTRAGTOR WILL PROTECT AND MAINTAIN EXI5TIN6 FIRE EXISTING DEMISING•1fVFf► TO BE REMOVED. B. 5PRINKLER 5Y5TEM DURING THE DEMOLITION OF THE TENANT 5PAGE. THE GENERAL GONTRAGTOR'5 FIRE PROTECTION CONTRACTOR WILL SURVEY THE 1 F EXISTING INTERIOR STUD 1�1AL 1 TO BE �. EXI5TIN6 5Y5TEM AND DOCUMENT REQUIRED REVI5ION5 FOR PROPER COVERAGE IN THE NEE RETAIL LAYOUT. PRIOR TO FABRICATION AND IN5TAL LATION OF THE EXI5TING DOOR AND FRAM TO BE REMOVED. MODIFIED 5Y5TEM THE CONTRACTOR WILL 5UBMIT 5HOP DRAWINGS TO THE REMOVE ALL EXI5TING FINI5H FLOORING TO LEASE LiNE5 tKLUDING GLLED DOWN CARPET, V.G.T. TILE LANDLORD, ARCHITECT AND CITY FOR APPROVAL. FLOORING AND DIVIDER 5TRIi 5. REMOVE ALL REMAINING FLOORING ADHE5IVE. G. DURING DEMOLITION, PROVIDE AND PLACE BRACING AND/OR SHORING A5 0 EXI5TING 5TRUGTtRAL COLUMN TO REMAIN. VERIFY 5AND LOCATION AND NOTIFY ARGHITEGT IF REQUIRED TO PREVENT MOVEMENT OF 5TRUGTURE. THE GENERAL CONTRACTOR 15 THERE ARE ANY DIFFER 1Zr. TO A55UME LIABILITY FOR ANY MOVEMENT, DAMAGE OR INJURY DUE TO LACK OF p ES 7L. TDt-WNTAIN J~, �' FIRE€LATIN. is , wz 5AFETY .PLANNING. MAKE SAFE THE 51TUATION °PRIOR TO �W(96EEDIN6 NITIA Axle D9 VE AI t �T7ECORA'. _ JGTURA2`COLUMi ENCLOS)RE_. PAT( t1 AND REPAIR TO MAINTAIN FIRE RATING DTV COLUMN. _ D. PRIOR TO DEMOLITION THE GENERAL CONTRACTOR 15 TO EVALUATE THE 015PO51TION OF ALL EXI5TING FUNCTIONING UTILITIE5. 5TANDARD CON5TRUGTION 1G REMOVE AND DISCARD ALL MILLWORK AND CABINETRY ETC. 5AFETY PRA( TIGE5 AND SAFETY MEA5URE5 ARE TO BE EXERGI5ED AND Ifl LEASE LINE. ENFORCED IN THE D15GONNEGTION, OF THESE UTILITIE5, REMOVE AND GAP A5 REQUIRED, 00 NOT J)5T ABANDON. 12 ANY 5U5PENDED CEILING ELEMENTS, FROM 5OFFIT5 AND FA5CIA5 (UNLE55 OTHERWISE NOTED), ARE TO BE E. MINIMIZE DAMAGE TO DEM1511,16 WALL DURING DEMOLITION. G.G. 5HALL PATCH AND REMOVED. REMOVE GEILING TILEE GRID AND HANGER WIRE AND ANY RELATED 5UPPORT5. REMOVE ALL REPAIR ANY DAMAGE A5 REQUIRED. 6OMPONENT5 TO METAL DECKING. F. GENERAL CONTRACTOR 15 TO PROVIDE AND MAINTAIN TEMPORARY LIGHTING d R13 REMOVE ALL REG1=55ED AND PENDENT LIGHTING IN THE SPACE. POWER THROUGHOUT THE GON5TRU(TION PR06E55 FOR THE 5AFETY AND lel REMOVE ALL DUCTWORK AND DUCT HANGERS TO DECK. OPERATION OF 6ON5TRUCTION EQUIPMENT. G. HVA(, CONTRACTOR TO IN5PEGT EXI5TING GONVITION5 PRIOR TO DEMOLITION AND 15 REMOVE i:X15T1NG UTILITIES'AND TOILET ROOM FACILITIES. PROPERLY GAP AND REMOVE A5 REQUIRED 6. WHETHER ANY GONIPRE550R REFRIGERANT LINES ARE PRESENT THAT BY 5TANDARD GONSTRUGTION PRACTICES. PREP TO EXTEND IF REQUIRED. MUST BE PROPERLY DRAINED (TO E.PA. 5TANDARD) PRIOR TO DEMOLITION. 1G� 5PRINKLER 5Y5TEM TO BE 5ALVA6ED AND PROTECTED DURING DEMOLITION FOR REVi5l0N tO:t'fEN H. REMOVE ALL DEMOLI5HED MATERIALS OFF 51TE IMMEDIATELY. FLOOR PLAN. 11 G_G. TO VERIFY EX15TENCE AND LOCATION OF GLEAN -OUT AND NOTIFY ARCHITECT OF FINDIN65. 1• PERFORM DEMOLITION IN ACCORDANCE WITH MALL AND CITY AUTHORITIE5. 1G EXI5TING MALL RAMP/5TAR5 IN MALL EGRE55 CORRIDOR/MALL GONGOUR5E TO BE REMAIN. J. ALL DEMOLITION PERFORMED IN EX6E55 OF THAT REQUIRED 15 TO BE REPAIRED WITHOUT G05T TO THE OWNER. R9 EXI5TING STOREFRONT GLAZING 5Y5TEM TO BE REMOVED. K. PHASE DEMOLITION A5 TO EXGE551VE N015E, VIBRATION AND/OR FUME5 50 A5 NOT TO DISRUPT ADJAGENT TENANTS. ANY DEMOLITION DEEMED EX(E551VE BY THE 20 EXI5TING STORirFRON7 ENTRY GRILLE TO BE REMOVED. LANDLORD 15 70 TAKE PLACE AFTER CENTER GL051NG OR A5 ARRANGED BY [21] EXI5TING 5TOREFRONT NEUTRAL PIER TO BE REMOVED. CENTER MANAGEMENT. L. BARRICADE A5 INDIGATED 15 TO BE CON5TRI CNT TED BY G.G. AT TENANTS EXPENSE. 22 EXI5TING STOREFRONT NEUTRAL PIER TO REMAIN. G.G. TO COORDINATE LOCATION AND 51ZE WITH MALL MANAGEMENT PRIOR TO INSTALLATION. M. G.G. TO PATCH AND REPAIR ANY DAMAGE TO EXI5TIN6 FIRE PROOFING ON WALL5, COLUMN5, FLOORS, BEAM5, J015T5, ETC. G.G. TO MATCH ANY NEW FIREPROOFING NEEDED WITH EXI5TING. N. G.G. TO REMOVE ALL ABANDONED PIPING AND GONGUIT5 ABOVE AND BELOA FLOOR SLAB AND PATCH FLOOR SLAB OPENIN65 A5 REQUIRED. 1/5' V.I.F. ` XTER10A I 2 3 11 2 JI J� HST 11 .00 ' 11 II r li I1 �1 I l �J4- J13^�I iI II 1 A 1 I I i !� 12 13 ! ! 1 1 i� 4 1 )i ! 18 '� Ili _ CJI II II I i ll III! IL ✓— r�! I l -w!Ir--- A r— Ili � �1 II !� 91111 r� r� LL4 L— 1111 5 1� I I U �Ni !I ill � � 111 ii VE111_ "f a I1 .a ' JB , III I I i III�..� � -- ®® —�I liI! 4 II ij L -o -if 5r� 9r �C AL I II 9 �1 11 -� I 1 r ll1�l 1��_�� 1 o 1 11 I ! 1 L. — j ilk, -I 1 a 9 I1 i'"l 1 III A L.. Jl - I !r !! �l !! 11®_jj LL A III !! it Til !! LU �i41 i 11�J ! ! 4 ! i! -- LV i"j Ili -_.---�__ ._ IIS L, !!! l �)� ! 1 7 10 12 13 llli )i _j 14 15 1G 17 of it I ! I I1 _1 10 12 13 �! ! !!! lli III r J 1'IL !! � L� jj� 11 - - ILiu k—FaTs!1' ILL= .� i S a C3jII°LI,li --- i — L — 22 1 � D2o—fg 11 2i 19 II 19 21 11 2� 1,-)22 r +, 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright O 2009 KEN NISCH, AIA All rights reserved Certification: DRAWINGS ISSUED FOR: f'`12,,I�1 intqy y, f,'M,�i! IdQ (jvY'�y'fi,17�}f,�y$Jby1l Arl f��[t}�4YJil� �����r 02.0q.Oq °i!•'" S �t {'� ,'fir i t'� �"�Y1t ! 41, �' 'd�� P t�ld �r , � ��v✓t f� �Var fKr r�- i ��� � ��f`���5 � r� ��i rfd?� ��r r � r +, 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright O 2009 KEN NISCH, AIA All rights reserved Certification: DRAWINGS ISSUED FOR: programming 0 schematic des. 02.0q.Oq D design dev. ©jbidding 11; permits 03.16.Oq 0 construction 11 landlord prelim. 02.0q -Qq lA landlord final 02.27.04 REVISIONS: f�.-�'.ARCWJTEECCTURAAL FLOOR PL 114 SCALE - `1 n,". j . TRUE NORTH Prj. no. —0q-012 Drawn RC, TH Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ARC141TECTURAL FLOOD PLAN K Sheet no. i' .i A S� !i - ...... -a t .. D,; NOTE: HEIGHT OF ( A5HHRAP GOUNTER TOPS SHALL COMPLY WITH 2003 166/AN51 A-111.1 SECTION q04. 56AL6, N.TS. el-csh-wp SCALE: 1/2" = Y-0' 2'-0' TYP. (MINIMIZE IF 6REATER THAN 2'-O') SCALE: N.T5. 61 -FA -M19 PAINTED D9,'01ALL. a+ IRKA)_ A)_ 0. P...ET. RII TO El E(,TC,AL 514EF 5 FOR PVf�!E IWD. PAINTED M -3F. 3/8' F.R.T. FREFI$9-.I IDD Bf\51F, FRCNOEcD 'BY %VER, Off, ) jITrERED, 96TALI ED, NO 10;1( f_0-LVXA 1KED AT FL r", AND TOP OF BASE Ar ,MALL SY TF34AW5 6E)f-RAL CaiTRACTOR. REFER TO DETAIL_ %5 04 SPEET A -lb FOR � �� JNF0PJ IATI0R. —SIiT' GYP W. EWER a4' FK T.:PL al'),W9 BACKER 0111 ?-ETAL 'STID FDID.15�iED FOR PAJMT. 3/8' F.R.T. PREEF1N15'iED MOF BASE, PROVIDED BY O'r�Ei2, GIl T,1'II T��D, � 1�i5"T.�LLED, r`,IID TG116HED-I)P16AI_ KED AT j FLOOR AND TOP GF BASE AT r1ALL BY TEXAJITS GENERAL (_0NT >lALTOTL REFER TO DETAIL_ 35 GN I SHEET A-1.6 FOR VCRE j INFGRNIATION. Al (ZOAM41 &r,_LO..L i FRAMINII AND 60N5TRucral TO BE PLUI+IB 5OUARE AND T1E UNLESS NOTED OTi-�EEZ N -col-encl FIXTURE FLOOR PLAN LE6ENP: FOR: 2200 - FLOOR TO CEILIN6 f IXTURE. PROVIDE FR.T. PLYWOOD 13LOCKIN6 IN GE1I, f x _ GIII II - FLOOR FIXTURE. 2203 -- FLOOR TO GEILINS FIXTURE. PROVIDE FR.T. PLYWOOD BLOGKIND IN CEILIN6, 31 G11123 - FLOOR FIXTURE. 3 Q 2656 - WALL MOUNTED FIXTURE. PROVIDE FKT. PLYWOOD BLOGKIN6 IN WALL. GI1124 -FLOOR FIXTURE. ® 2615 - FLOOR FIXTURE. 6.G. TO ANGHOR fIXTURE TD FLOOR. 9 landlord final CI1125 - FLOOR FIXTURE. �5 2676 - FLOOR FIXTURE. 6.G. TD ANGHOR FIXTURE TO FLOOR.�4 GI1126 - FLOOR FIXTURE. ® G206 - WALL MOUNTED FIXTURE: PROVIDE fR.1 PLYWOOD BLOCKING IN, ALL ;; . r 61114,1) - FLOOR FIXTURE. O (I� I 3�6 200q - FLOOR FIXTURE. ® G2b60 - WALL MOUNTED WART ROE1E. -PROVIDE FR.T. PLYWOOD BLOCKING IN WALL ® 2010 - FLOOR FIXTURE. {i 62661 - WALL MOUNTED WARDROBE. PROVIVE F.R.T.-PLY 'SOD BLOCKw5 IN Aqi. 2117 - FLOOR FIXTURE. 10 62662 - WALL MOUNTED WARDROBE. PROVIDE FKT.FtYWOOD:.BLOrKIN6 4J.HAU. ® I I I 62665 - WALL MOUNTED WARDROBE. T'ROVIDE FK7. ftlrWaD BLOGKR46 IN WALL.. 60 I n 12 G2685 - WALK-IN GL05ET. � 231I - FLOOR FIXTURE. I3 G28g0 - WALL MOUNTED WARDROBE. PROVIDE fR. T. PLYWQGV BLOGKIN6 IN MALL' 42 2403 -FLOOR FIXTURE. 14 G28g1 - WALL MOUNTED WARDROBE. PROVIDE FR.T. I='L't'*VOD BLOI IN WALL. 43 I.. 15 C28g2 - WALL MOUNTED WARDROBE. PROVIDE FRT_ PlYwDOD BLOCKING IN wL,L,.. 44 2b12 - FLOOR FIXTURE, Ih G28g3 - WALL MOUNTED WARDROBE. PROVIDE F.R.T. PLYKQOD BLOGKIN6 IN INA..I... s 45 203 - FLOOR FIXTURE. I7 G28g4 - WALL MOUNTED FIXTURE- PROVIDE F.R.T. PLYWOOD BLOGK#r IN HALL.qb --- 26T1 - FLOOR FIXTURE. 18 63180 - WALL PANEL. PROVIDE FR.T. PLYWOOD BLOGKIN6 IN WALL. 47 SCALE: N.T5. 61 -FA -M19 PAINTED D9,'01ALL. a+ IRKA)_ A)_ 0. P...ET. RII TO El E(,TC,AL 514EF 5 FOR PVf�!E IWD. PAINTED M -3F. 3/8' F.R.T. FREFI$9-.I IDD Bf\51F, FRCNOEcD 'BY %VER, Off, ) jITrERED, 96TALI ED, NO 10;1( f_0-LVXA 1KED AT FL r", AND TOP OF BASE Ar ,MALL SY TF34AW5 6E)f-RAL CaiTRACTOR. REFER TO DETAIL_ %5 04 SPEET A -lb FOR � �� JNF0PJ IATI0R. —SIiT' GYP W. EWER a4' FK T.:PL al'),W9 BACKER 0111 ?-ETAL 'STID FDID.15�iED FOR PAJMT. 3/8' F.R.T. PREEF1N15'iED MOF BASE, PROVIDED BY O'r�Ei2, GIl T,1'II T��D, � 1�i5"T.�LLED, r`,IID TG116HED-I)P16AI_ KED AT j FLOOR AND TOP GF BASE AT r1ALL BY TEXAJITS GENERAL (_0NT >lALTOTL REFER TO DETAIL_ 35 GN I SHEET A-1.6 FOR VCRE j INFGRNIATION. Al (ZOAM41 &r,_LO..L i FRAMINII AND 60N5TRucral TO BE PLUI+IB 5OUARE AND T1E UNLESS NOTED OTi-�EEZ N -col-encl FIXTURE FLOOR PLAN LE6ENP: FOR: 2200 - FLOOR TO CEILIN6 f IXTURE. PROVIDE FR.T. PLYWOOD 13LOCKIN6 IN GE1I, f x ® GIII II - FLOOR FIXTURE. 'CI design dev. 2203 -- FLOOR TO GEILINS FIXTURE. PROVIDE FR.T. PLYWOOD BLOGKIND IN CEILIN6, 31 G11123 - FLOOR FIXTURE. 3 Q 2656 - WALL MOUNTED FIXTURE. PROVIDE FKT. PLYWOOD BLOGKIN6 IN WALL. GI1124 -FLOOR FIXTURE. ® 2615 - FLOOR FIXTURE. 6.G. TO ANGHOR fIXTURE TD FLOOR. 9 landlord final CI1125 - FLOOR FIXTURE. �5 2676 - FLOOR FIXTURE. 6.G. TD ANGHOR FIXTURE TO FLOOR.�4 GI1126 - FLOOR FIXTURE. ® G206 - WALL MOUNTED FIXTURE: PROVIDE fR.1 PLYWOOD BLOCKING IN, ALL ;; . r 61114,1) - FLOOR FIXTURE. O 62651 -WALL MOUNTED FIXTURE. PROVIDE F.R.T. PLYWOOD BLOGK1N67 IIPI.IALL. 3�6 200q - FLOOR FIXTURE. ® G2b60 - WALL MOUNTED WART ROE1E. -PROVIDE FR.T. PLYWOOD BLOCKING IN WALL ® 2010 - FLOOR FIXTURE. g� 62661 - WALL MOUNTED WARDROBE. PROVIVE F.R.T.-PLY 'SOD BLOCKw5 IN Aqi. 2117 - FLOOR FIXTURE. 10 62662 - WALL MOUNTED WARDROBE. PROVIDE FKT.FtYWOOD:.BLOrKIN6 4J.HAU. ® 2125 - FLOOR FIXTURE. I I 62665 - WALL MOUNTED WARDROBE. T'ROVIDE FK7. ftlrWaD BLOGKR46 IN WALL.. 60 22,155 .- FLOOR FIXTURE. 12 G2685 - WALK-IN GL05ET. 4I 231I - FLOOR FIXTURE. I3 G28g0 - WALL MOUNTED WARDROBE. PROVIDE fR. T. PLYWQGV BLOGKIN6 IN MALL' 42 2403 -FLOOR FIXTURE. 14 G28g1 - WALL MOUNTED WARDROBE. PROVIDE FR.T. I='L't'*VOD BLOI IN WALL. 43 2404 - FLOOR FIXTURE. 15 C28g2 - WALL MOUNTED WARDROBE. PROVIDE FRT_ PlYwDOD BLOCKING IN wL,L,.. 44 2b12 - FLOOR FIXTURE, Ih G28g3 - WALL MOUNTED WARDROBE. PROVIDE F.R.T. PLYKQOD BLOGKIN6 IN INA..I... s 45 203 - FLOOR FIXTURE. I7 G28g4 - WALL MOUNTED FIXTURE- PROVIDE F.R.T. PLYWOOD BLOGK#r IN HALL.qb 26T1 - FLOOR FIXTURE. 18 63180 - WALL PANEL. PROVIDE FR.T. PLYWOOD BLOGKIN6 IN WALL. 47 .2b -7q - FLOOR FIXTURE. Iq 63183 - WALL END PANEL. PROVIDE FR.T. PLYWOOD BLOGIKINS IN WALL. ® 2b80 - FLOOR FIXTURE. GI 1115 - WALL MOUNTED WARDROBE. PROVIDE F.R-T. PLYWOOD BLOCKM6 IN WALL. 2bg3 - FLOOR FIXTURE. 21 GIIII6 - WALL MOUNTED WARDROBE. PROVIDE F.R.T. PLYWOOD 5LOGKIN5 IN WALL. 26g8 - FLOOR FIXTURE. 0 ( llllq - WALL MOUNTED WARDROBE. PROVIDE FR.T. PLYWOOD BLOLKIN5 IN WALL. 51 26gq -'FLOOR FIXTURE. G11120 - WALL MOUNTED WARDROBE. PROVIDE F.R.T._PLYWOOD BLOCKING IN WALL. 3532 - FLOOR FIXTURE. ® 11160 - WALL MOUNTED FIXTURE. PROVIDE F.R.T. PLYWOOD BLOCKING IN WALL. 53 8552 - FLOOR FIXTURE. 25 G20b3 - FLOOR FIXTURE. 8.554 - FLOOR FIXTURE. 2�b 62010 - FLOOR FIXTURE. @) b555 - FLOOR FIXTURE. 21 G2213 - FLOOR FIXTURE. 11158 - FLOOR FIXTURE. ® 64084 - FLOOR FIXTURE. 5I 11163 - FLOOR FIXTURE. q G40b5 - FLOOR FIXTURE. 21gO - WALL MOUNTED FIXTURE. PROVIDE F.R.T. PLYWOOD BLOGKINO IN WALL. REFER TO DETAIL #3 ON THI5 SHEET. NO TP FIXTURE ANIS E5RES5 GENERAL NOTES: A. SEE FIXTURE DRAWINGS FOR DETAILS. FIXTURING NOTED TO BE INSTALLED BY G.G. B. G.G. TO PROVIDE F.R.T. BLOCKING AT ALL LOCATIONS FOR ALL PERIMETER FIXTURES, HOOKS, SCONGES ETC. A5 SHOWN. COORDINATE W/ SHOP DRAWIN65 FROM FIXTURE CONTRACTORS. BLOCKING TO BE FIRE -RATED A5 REQUIRED BY ALL CODES HAVING JUR150I6TION. G. G.G. TO PROVIDE ELEGTRIGAL POWER AND FINAL HOOK-UP5 FOR ALL STORE FIXTURES WHICH CONTAIN ELECTRICAL ELEMENTS / LIGHTING. G.G. TO COORDINATE W/ SHOP DRAWINGS TO BE PROVIDED BY F.G. THE FIXTURE CONTRAGTOR 15 RESPONSIBLE FOR THE U.L. L15TING OF ALL FIXTURES REQUIRING ELE6TR16AL. SEE FIXTURE DRAWINGS FOR DETAILS. D. FITTING ROOM DOORS TO BE SUPPLIED BY G.G. G.G. TO PROVIDE F.R.T. BLOCKING, .JAMBS d HEADERS / SUPPORT -TO INSTALL FITTING ROOM DOORS. REFER TO SHEET A-0.2 FOR FURTHER INFORMATION, G.G. TO VERIFY WITH MANUFACTURER FOR EXACT WALL THIGKNE55E-5. E. G.G. TO PROVIDE ALL FINISH/MATERIAL SAMPLES FOR FINAL APPROVAL. F. G.G. TO INSTALL STANDARD WALL UNIT 51 (SHELVING AND BRA( KETS) BASED ON WALL BAY TYPICAL 5ET-UP TYPE SHOWN ON ELEVATION. SEE ELEVATIONS AND DETAILS OF MER( HAN-015IN6 5Y5TEM5. 6. ALL OWNERS SUPPLIED MATERIALS, MILLWORK AND FIXTURES SHALL BE RECEIVED, STORED, A55EMBLED AND INSTALLED BY G.G. G.G. SHALL COORDINATE ABOVE ITEMS WITH ARCHITECTURAL DRAWINGS, SHOP DRAWINGS AND HdM FIELD REP. H. G.G. SHALL INSTALL FLOOR FIXTURES AND GASHWRAP PER DRAWIN65. COORDINATE FINAL FLOOR FIXTURE PLACEMENT WITH Hd M REP AND LOCAL CODES. E6RE55 PATH MUST BE MAINTAINED. L FLOOR FIXTURES ARE REPRESENTATIONAL ONLY. MAINTAIN A MIN. OF 3b' AR"FLOOR FIX`WPR 5 AND 441, AT PERIMETER / FLOOR FIMES DURING FINAL INSTALL COORDINATE EXACT FIXTURES AND LOCATIONS WITH HdM FIELD REP. REFER TO H8M "HOW TO BUILD" FOR FIXTURE TYPES AND MORE INFORMATION. ,55 AND FIXTURE. -FLOOR L SCALE: 1/8° = P-0" NOTE: ,.._ I. ALL DOORS IN ALCOVES SHALL COMPLY TO THE CLEARANCES FOR FRONT APPROACH. 2. 12" d IS" ARE REQUIRED IF DOOR HAS BOTH A LATCH AND A CLOSER. �? ,n 5'-0° MIN. FRONT APP, TYP. 1 Ptd- /PULL DISTANCES ENLARGEDFAIL F -J j 56ALE: 1/4' = 1'-0" ADA. COMPLIANT MANEUVERING GLEARAN(E5 AT DOORS pa -dr -pull FIXTURE KEY NOTES: AFLOOR TO CEILING FIXTURES. G.G. TO PROVIDE 1/2" F.R.T. PLYWOOD BLOCKING IN GEILING. VERIFY LOCATION WITH ON-51TE Hd M REP. G.G. TO PROVIDE 1/2" F.R.T. PLYWOOD BLOGKING FOR ALL WALL FIXTURES. BLOGKING IN WALL TO 2 EXTEND FROM FLOOR TO ADJACENT GEILING. 3 1 GEILING HUNG FIXTURE. G.G. TO PROVIDE 1/2" F.R.T. PLYWOOD BLOGKING IN GEILING. VERIFY LOCATION WITH ON-51TE HdM REP. REFER TO SHEETS A-2.1, A-2?, A-2.3, AND A-2.4 FOR MORE INFORMATION. FLOOR MOUNTED FIXTURE. G.G. TO PROPERLY SECURE FIXTURE TO FLOOR WITH STEEL PLATE AND BOLTS, VERIFY LOCATION WITH ON-51TE HdM REP. aEGRE55 PATH. OOLUMN MIRROR GENERAL NOTE: MIRROR LOCATION SHOWN ARE NOT NECESSARILY INDICATIVE OF FINAL LOGATIONS. G.G. SHALL COORDINATE WITH Hd M REP. PRIOR TO FABRICATION AND INSTALLATION OF COLUMN MIRRORS. EA DRAWINGS ISSUED FOR: ❑ programming schematic des. 0Z0q.0q 'CI design dev. ❑ bidding ® permits 03.16.Oq EJ construction 1111 landlord prelim. 02.Oq.Oq 9 landlord final 02.27.0q REVISIONS: Prj. no. 8 -20q -0I2 Drawn RG, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: EGRESS AND FIXTURE FLUOR PLAN Sheet no. 3r-1 l/Ib" 2 EMAL 5PAGE5 & 5-111/169 EA. Fri;::; b% �2 -Yb' _ 5GALE: 1/4" = 1'-0" 3 F-12 I A-55 EGRE55 GORRI DOR gO51base GENERAL NOTE5: A. SEE FIXTURE DRAWINGS FOR DETAIL'. FIXTURING NOTED TO [IT I I I - BE INSTALLED BY G.G. B. G.G. TO PROVIDE F.R.T.. BLOGKING AT ALL LOGATION5 FOR ALL PERIMETER FIXTURES, HOOK5, 5GONGE5 ETC. A5 SHOWN. fl COORDINATED W/ SHOP DRAWING FROM FIXTURE u"GONTRAGTOR5. BLOGKING TO BE FIRE -RATED A5 REQUIRED [Ea,[ 5 EQUAL SPACES e 3'-1116' EA. = 15'-1 1/4' EQ. BY ALL GODE5 HAVING J)RISDIGTION. ' t LU w MLL STANDAR05 L CvENP: Q a N NOTE: REFER TO 5HEET5 A-I.I, A-1.2, A-13, A-1.4 AND A-1.5 FOR WALL GON5TRUGTION TYPES. w r W SURFACE MOUNTED 5TANDARD FOR BAGK OF HOUSE APPLICATION, 5PA61NO @ 3'-I 1/16" O.G., TO BE PROVIDED BY TENANT AND IN5TALLED 13`t' C.G. REFER TO DETAIL 03 ON L SHEET A-5.5 (DETAIL 05 ON SHEET A-55 FOR 5TOGKROOM APPLI( ATION5) FOR MORE INFORMATION. w LU Q, Q 5ALE5 AREA 5TANDARD5, 5URFA6E MOUNTED, 'PA( INC2 o 2 EQUAL 5PAGE5 2'-0 5/8" (625mrn) OL., TO BE PROVIDED 8Y TENANT AND 3'-I 7/16' EA w INSTALLED BY 6.6, REFER TO DETAIL #4 ON 5HEET A-55 o W FOR MORE INFORMATION. EQ. = 6'-2 l/S" Ea. a� SALES AREA 57ANDARDS, SURFACE MOl1NTED, 5PAC1N6 CL -' 2'-0 5/8" (625mm) O.G., TO BE PROVIDED BY TENANT AND EQ. 6 EQUAL 5PAGE5 ®3'-1 l/16" EA. = 18'-8 518" EQ. a INSTALLED BY G.G., REFER TO DETAILS #1 AND #2 ON SHEET A-5.5 FOR MORE INFORMATION. cn „ N � p W � Y W gew -i® —�-__._._.-----IPI- — -._.._ - __...s_; -.-. _._._-_.__- .., _.- ___ ----—.- 2 EGUAL 5PAGE5 2 EQUAL 5PA6E5 3'-11/16" EA. @ 3'-I 1/I6" EA. = 6-2 IV EQ. = V-2 1/8' EQ. 3 EQUAL 5PAGE5 0 2'-0 518' EA. = 6-11/&" 1'-2 4b. q E1141LARGED PAIIIALL STANDARDS PLAN 5GALE: 1/4" = 1'-0' -- EXTERIUM 3 EQUAL 3 EQUAL 5PAGE5 ® 5PAGE5 @ 2'-0 5/8" EA. 2'-0 5/8' EA. = 6-116" - = 6-1 1/8" . i q l ' 1'- 5/& . - 1'-5 51&' q 10 �k4F---r--a-__-. 2 EQUAL g05gbase Mgo 3 EQUAL 5PAGE5 0 10 EGJq AL SPACES 2'-0 5/8" EA. €1 2'-0 5/8" = 6-1 1/8" EA. = 20'-6 1/4' q 7118' 1'4 518" 2'-4 2 EQUAL 5PAGE5 2 A-! 10 EQUAL 5PA( E5 ® 2'-0 5/8" EA. = 20'-6 1/4" E6RE55 CORRIDOR H U— WHPFA 5ALE5 FLOOR 51-AGE5 @ 2 -0 -//8 2'-0 5/8' EA. EA. n n n n n n n n n n n _ TT. G65HWRAP A-55 o _ - - LM b E03)AL 2 2 8 EQUAL c "' 5PAGE5 A-55 A-5.5 5PAGE5 2'70 5/8' 2'-0 5I8" � N 11 c�LU EA = Ib' -5a 8 7/8" 101,3EA. = 16-5" LU r W G m n n n n n n n T" n n n n n n n n Al z 0 SALES FLOOR FITTING ROOMS OUR DEt , —® I i UJALL STAWPARD6.9FLOOR r; 'GALE: 1/0" , 1'-0" NO TP ,fy F'j �,fj,+, th}(>+�'[frv��a Mr ipU; '•a' "S'`r� rp. }fi kM,..1 farfJ� Yli��f���r+lj'�FJ� I � 11i��? Clf1Y�'q w�pq �k'�xJ,4sq IvtF7�T,u L� 4< 1F kr i�6f �''�d'' , f� k v Y ✓p,a ���nrt 77yy',A, Q 1 -� ��� � Ad 4t�,r j+'r il,�f'}� F'.S �a�.za Rl�rr3 wr} f 11 �}peta,�p r,,6 In ' rS�) efrxt'�t , rr � !�7q r�r yr ++tier's tett r4,� .� XeL r 4 r6 d �s pr,n ,� of ari{s f 29110Inkstera Suite 11 Southfield, MI 48034 USAi 4: 355 i:'1 ' 355 0895 Fax t i © 2009 KEN NISCH, AIA All rights reserved ;i 9 � r i �i i RETAIL DESIGN CONSULTANT h ygtAitl��f ,} q((r(rrdsi.JGA mc1 ��,fdex,Qtl��,e29110 Inkster Road Suite 200 Southrield, MI 48034 USA 0890 248 355 0895 Fox JGA „� i I r 57 I i i 1 DRAWINGS ISSUED FOR: 0 programming 9 schematic des. 02,0q_0q 0 design dev. • bidding ® permits 03.16,0q 0 construction ® landlord prelim. 02.0q,0q 9 landlord final 02.27.0 REVISIONS: Prj, no. 8-209-012 Drown RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: WALL STANDARDS FLXR FLAN Sheet no. 'I 5GALE. 1 I/2" : I' -O' r'6--,,rdrb lT C ILINC2 -TION. REFER TO SHEET 4 MORE INFORMATION. 7AP GON5TRUGTION. ) 5HEET5 A -2_I, 23, A-2.4, AND R LOGATION5 AND Df;� VIATION. C IN KWOROBE FIXTURE. ;ANT LI6M5 TO BE: 4W - COLOR 840 1-516 DUCT # 14560214 �bW COLOR 840 1-111b DUCT fl 145bO226 SHEET5 F-1.3, F-1.4, FOR LO(,ATION5. g5TRKTION. ) SHEETS A-I.I, 3, A-14, AND A-15 E INFORMATION. ANG! E. 2ROBE FIXTURE. 'O 13E ANCHORED TO T WAI I Wff 1.1 MOUNT N6 REFER TO SHEETS F-13, F-1.4, AND F-13 E INFORMATION. f1T41„ty.:,.,. ANGLE. )OR. SER TO 5HEET MVRE MORiMAT01. .N CAwlAwl CORRIDOR I WARDROBE FIXTURE. . TO SECURE FIXTURE TO JACENT WALL VIITH )NTING ANG1LE5. REFER DETAIL #3 ON THI5 SHEET Z MORE INFORMATION. ZDROBE FIXTURE TO BE rALLED I IV FROM ;E OF ADJACENT SHED HALL AS SHOWN. -L GON5TRUGTIQN. =ER TO SHEETS A-I.I, 2, A-1.3, A-1.4, AND A-15 Z MORE INFORMATION. SCALE: W = 1'-0° r DA5HED LINES INDICATE WALL BA5E BELOW. REFER TO SHEET A-1.6 FOR MORE INFORMATION. FIN15H EDGE OF L -BEAD GYP. BD. HALL TO BE 1 1/4" BEHIND FRONT FACE OF WARDROBE FIXTURE A5 5HOWN (TYP.). G.G. TO L -BEAD ALL GYP. BD. CORNERS A5 SHOW FINISH DIMENSION OF L -BEAD TO ADJAGENT PgARDROBE FIXTURE TO BE I/8" A5 5HOWN (T(P). NEW WARDROBE FIXTURE. G.G. TO SECURE FIXTURE TO ADJACENT WALL WITH MOUNTING ANGLES. REFER TO DETAIL #3 ON THI5 SHEET FOR MORE INFORMATION. HALL 6ON5TRU( TION. REFER TO SHEETS A-1.1, A-12, A-1.3, A-1.4, AND A -IS FOR MORE INFORMATION. P5-wrdrb NORTH 5C;ALE: 1/8" - I'-0" 5duthfield, MI 48034 USA DRAWINGS ISSUED FOR: O programming 11 schematic des. 02,0q.Oq 0 design dev. LU 0 permits 03.16.Oq 0 construction 10landlord prelim. 02.0q_Oq 19 landlord final U) REVISIONS: LLI L g LU L �A otu ry, O 0i Luu) r �7 DRAWINGS ISSUED FOR: O programming 11 schematic des. 02,0q.Oq 0 design dev. 0 bidding 0 permits 03.16.Oq 0 construction 10landlord prelim. 02.0q_Oq 19 landlord final 02.27.Oq REVISIONS: Prj. no. 8-200-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: FIXTURE LIGHTING FLOOR PLAN Sheet no. TYf ma 5GALE: 1/4' = t' -D" 1 TYP. i YP. TYf • i F-1.3 1 TYP. "- —% Tr- -- TYP. TYP - - - - it . A FiXTURE LIGHTING- FLOOR PLAN TYP. TYP. TYP. g057bme -Tv F- L3 t TYP. F-13 TYP_ r r�-per U r� 3 M schematic des. 02.0q.0q OF -L3 -t3 ❑ bidding P permits rfP. ❑ construction 0 landlordprelim. TYP. 9landlord final 02.27.Oq REVISIONS: 1 TYP a F -t3 I TYP. F-13 TYP. 1 TYP. TYP. 2F -f.3 TYP, -f `(4'. I . 1 TYP'. TV. `--- TYP I 3 1 F-13 f -1 -3F -L3 TV.� TYP. 2 TYP: 2 -I3- _ 2 TYP. -ENLARGEDU SIGHTING FLOOR PLAN SCS+ E- 1/4° = V-0- TYP. / -1 _1105-Ibme, - . 1 3 F-13 rf P. 1 F-13 l TYP. ( TYP. TYP. Im 0 flu fp. a ( FIXTURE L16HTIN6 KEY NOTES: F-13TYP. f TYP. FLUORESCENT LIGHTS IN WARDROBE FIXTURE. REFER 1 TO THI5 5HEET AND 5HEET5 F -H, F-1.2, F-1.3, F-1,4, AND 1 / � ELECTRICAL SHEETS FOR MORE INFORMATION. I 7 WARDROBE FIXTURE. REFER TO THI5 5HEET AND 5HEET5 F -H, F-1.2, F-1.3, F-1.4, F-15, AND ELEGTRIGAL 3 3 5HEET5 FOR MORE INFORMATION. F-1.3 F-13 TYP. TYP. / 1 3 F-13 F-13 F-13 TYP. TYP. TYP. I TYP. 4 - - 777 - r - - - - - .� -_ F-13 2 2 - - F-13 TYP. F-13 F-13 , TYP. TYP. TYP. ENLARGED FIXTURE LIGHTING FLOOR PLAN 56ALE: 1/4'= I'-0" g05lbo5e 2 F-13 2 TYP. F-13 TYP.F-13 w , TV. F-1-3 - -- TYP F-1-3 F -L3 F-13 j I TYP. " TYP. TYP. TYP. - v 0 o o I j 1 � , 1 i - TYP. F -L3 TYP. . I ; F-13 F-13 TYP. TYP- 3 3 F-1.3 I F 13 TYP. I TYP- TYP. i 'F-13 F-13 TYP. TYP. 2 1 F-13 �,-13 I J 1 / ( TYP F-13 � 7YP. "r-13 F-1-3 TYP.- - - - - - - - - - - 1`-]3 - -- --- - ------- (@ ---- --- -- - - - � I `. 3. .. TYP. TYP. !, �• F - 1-3 TYP. I F-13 F-13 F-13 F-13 TYP. TV. TYP. TYP. 3 F-13 TYP. ENLARGED FIXTURE LIGWING FLOOR PLAN. g05lbc6o CN ❑ programming M schematic des. 02.0q.0q ❑ design dev. ❑ bidding P permits 03.16.0q ❑ construction 0 landlordprelim. 02.0q.0q 9landlord final 02.27.Oq REVISIONS: Prj. no. 45-209-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only, Drawing title: ' ENLARGED FIXTURE LIG14TING FLS ; PLAN Sheet no. ENLARGEDME LIG14TING FLOOR ft"I AN 5GAL E: 114' = 1'-0° g05-bo5e �4 �3 FIXTURE LI HTIN6 KED' NOTE5: FLUORE5GENT LI6HT5 BEHIND POP -OUT HALL PANEL 5TANDARD5. REFER TO 5HEET F-1.2 AND DETAIL5 01 a AND #2 ON 5HEET A-5.5 AND EL EGTRIGAL 5HEET5 FOR MORE INFORMATION. 2 POP -OUT HALL PANEL 5TANDARDS. REFER TO 5HEET5 F-1.2, A-3.2 AND DETAIL5 01 AND #2 ON 5HEET A-5.5 AND ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. LU tu Ir tu 9 LU 5 < 1 LU I 2 to r DRAWINGS ISSUED FOR.- 0 OR. 0 programming ® schematic des. 02.0a1a0q 0 design dev. 0 bidding 1111 permits 03:10.0 Cl construction ®landlordprelim. 02.0C1.0g N landlord final 02.2..0q REVISIONS: i I � Pr;. no. 8-209-012 Drawn RCI TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Sheet no. I .1 J i\ i �? 1 IM I •f f Y .F 4 4 29110 1nkster Rood } } Suite 200 Southfield, MI 48034 USA . 248 355 0890 248 .355 0895 Fox 1 Copyright2009 KEN NISCH, AIA All rights reserved f. Certification: I g yg ds� 1 4,) '!S i rkro f"N IIS:" 4 O� Ij l r Consultants: } RETAIL DESIGN CONSULTANT `f f� 29110 Inkster Road tx, Suite 200 Southfield, MI 48034 USA, t t 248 355 0890-: 248 355 0895 Fax Ccprioi 0 Mn .Min. Inv nu ;P(•'_. *a www.jga.com ,a JGA Pr j #: 1-209-051: LU tu Ir tu 9 LU 5 < 1 LU I 2 to r DRAWINGS ISSUED FOR.- 0 OR. 0 programming ® schematic des. 02.0a1a0q 0 design dev. 0 bidding 1111 permits 03:10.0 Cl construction ®landlordprelim. 02.0C1.0g N landlord final 02.2..0q REVISIONS: i I � Pr;. no. 8-209-012 Drawn RCI TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Sheet no. I .1 J ARGH I TEGTURAL WALL TYPE LEGEND: NOTES: A. REFER TO SHEET A-5.1 FOR WALL 5EGTION5 UNLESS OTHEPH15E NOTED. B. PLYWOOD REQUIRED IN WALL FOR ALL SALES AREA WALLS WITH 5TANDAR05. REFER TO SHEETS F-12 AND A-5.1 FOR MORE INFORMATION. G. IN ALL A.G.T. CEILING AREAS GYP. BD. TO EXTEND 3' ABOVE ADJACENT CEILING. EXI5TIN6 DEM151N6 WALL 5TU05 BY L.L. `I I G.G. SHALL PROVIDE ONE (I) LAYER OF <3> TYPE 'X' 6YP. BD. OVER 5TUD5 TO COMPLY WITH FIRE RATING IF NOT EXISTING. 6.G. TO �s PROVIDE SOUND ATTENUATION INSULATION IN EX15TINO DEM151146 WALL5. NEW I -HOUR RATED WALL CONSTRUCTION, ^� 3 5/8" METAL STUDS, W/ ONE (1) LAYER OF 5/8" TYPE "X' GYP. BD. ON BOTH SIDES -_�- TO UNDERSIDE OF DECK ABOVE. NEW NON -RATED WALL GONSTRUGTION. 3 518" METAL 5TUD5 W/ ONE (1) LAYER. OF 5/8" GYP. BD. ON EXP05EP 51DE OF 5TUD5. IN ALL A.G.T. CEILING AREAS GYP. BO. 15 TO EXTEND A MIN. OF 3" ABOVE FIN15HEP CEILING. NEW NON -RATED 6' METAL 5TUD WALL OGON5TRU6TION. ON BOTH 51DE5 OF 57UD ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT CEILING. NEW NONRATED FURRED OUT WALL GON5TRMTION. 15/13" METAL 5TUD5. ON EXPO5E1) SIDE OF STUDS ONE (1) LAYER .- - OF 1/2" F.R.T. PLYWOOD TO 8'-0° A.F.F. AND GYP. BD. FILL FROM 8'-0" A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD• FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. NEW NON -RATED 3 518' METAL 5TUD WALL GON5TRUGTION. ON EXP05EP SIDES OF 5TUD5 ONE (1) LAYER OF 112' F.R.T. PLYWOOD TO S' -O" A.F.F. AND GYP. BD. FILL r FROM 8'-0" AFF. TO ADJACENT CEILING. �1 OVER PLYWOOD AND GYP. BD. FILL, G.G. TO IN5TALL ONE (1) LAYER OF 5/8" r,YP. BD. TO ADJACENT CEILING. NEW FURRED OUT WALL CONSTRUCTION. 3 518" METAL STUDS. ON EXP05ED SIDE OF STUDS ONE (1) LAYER OF 112" F.R.T. PLYWOOD O - TO ADJACENT CEILING. OVER PLYWOOD ONE (1) LAYER OF 5/8" GYP. BD TO ADJACENT GEILIN6. NEW I -HOUR RATED 3 5/8" METAL STUD WALL CONSTRUCTION. ON BOTH 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/8" TYPE 'X" GYP. BD. TO UNDERSIDE OF DECK. ON 5ALE5 FLOOR 51DE OF 5TU15 ONLY OVER O , _ LAYER OF TYPE "X" GYP. 13D. ONE (I) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-0' A.F.F. AND 6PY. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT GEILIN6. NEW NON -RATED WALL CONSTRUCTION. 3 5/8" METAL STUDS. ON 5ALE5 FLOOR SIDE OF STUDS INSTALL ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-0" A.F.F. AND GYP. BD. FILL FROM 8'-0" A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. ON SALES 015PLAY WINDOW 51DE OF STUDS IN5TALL ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 12'-0" AF.F. AND GYP. BD. FILL FROM 12'-0" A.F.F. TO ADJACENT CEILING. OVER FLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 518" GYP. BD. TO ADJACENT CEILING. NEW NON -RATED b" METAL STUD WALL CONSTRUCTION. ON SALES FLOOR 51PE OF STUDS ONE (1) LAYER OF 112" F.R.T. PLYWOOD TO 8'-0" A.F.F. AND GYP, BD, FILL FROM 8'-O" A.F.F. TO ADJACENT CEILING. OVER O� PLYWOOD AND 6YP. W. FILL, G.G. TO INSTALL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. ON WARDROBE FIXTURE 51DE OF 5TUD5 ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. NEW NON -RATED (9" METAL STUD STOREFRONT _ } ENTRY GRILLE WALL CONSTRUCTION. ON <L> ---� �y BOTH 51DE5 OF STUDS ONE (1) LAYER OF 5/8' r --------f GYP. BD. TO ADJACENT CEILING. REFER TO SHEETS A-4.1 AND A-4.2 FOR MORE INFORMATION AND DETAILS. NEW NDN -RATED 3 5/8' METAL STUD WALL NEW NONRATED 3 518" METAL 5TUD WALL ARGH I I E I RAL KEY NOTE): GON5TRUGTION. ON SIDE OF STUDS ADJACENT CONSTRUCTION. ON TOILET ROOM SIDE OF TO SIDE OF HARDROBE FIXTURE/5ALE5 STUDS ONE (1) LAYER OF 112" GEMENT BOARD FLOOR SIDE INSTALL ONE (1) LAYER OF 518" TO 4'-1" A.F.F. AND ONE (1) LAYER OF 112" al LEASE LINE. G.G. TO VERIFY IN FIELD. GYP. BD. TO ADJACENT GEILI46. ON 51DE OF OT GREENBOARD FROM 4'-q' A.F.F. TO 3" a NEUTRAL PIER. OSTUDS ADJACENT TO BACK OF WARDROBE ABOVE ADJACENT CEILING. ON 'O FIXTURE/FITTING ROOM 51PE INSTALL ONE (1) GORRIDOR/JANITOR'5 GL05ET SIDE OF r------- �-" NEW STOREFRONT ENTRY AND SAFETY 6LA55 6LAZI% SYSTEM - REFER TO SHEETS LAYER OF I/2" F.R.T. PLYWOOD 70 8 -0 A.F.F. STUDS ONE (I) LAYER OF 5/8 GYP. BD. TO 3 a AND GYP. BD. FILL FROM 8'-0" A.F.F. TO ABOVE ADJACENT CEILING. A-0.2, A-4.1, AND A-42 FOR MORE INFORMATION. ADJACENT CEILING. OVER PLYWOOD AND NEW 50UND ATTENUATED NONRATED WALL NEW 5EN50RMATIG FLOOR MAX SYSTEM. G.G. TO COORDINATE WITH SHOP DRAWINGS GYP. BD. FILL INSTALL ONE (1) LAYER OF 518" GON5TRUCTION. 3 518" METAL 5TU05 W/ 5/8" F AND 5EN50RMATIG. GYP. BD. TO ADJACENT CEILING. GYP. BD. ON EACH SIDE OF STUDS TO BOTTOM OF METAL DECK ABOVE. FILL ALL STUD NEW STOREFRONT PLATFORMS BY G.G. REFER TO 5TOREFRONT SEGTION5 ON SHEET NEW NONRATED FITTING ROOM PARTITION I CAVITIES FULL HEIGHT WITH FIBERGLASS a A-4.4 FOR MORE INFORMATION. G.G. TO INSTALL FLUSH ELECTRICAL BOXES AS, TO 8'-0" A.F.F. 2 I/2° METAL STUDS W/ O " REQUIRED IN PLATFORM. BOXES TO BE WIREMOLD 88513 FLOOR BOXES FOR WOOD ONE (I) LAYER OF I/2' F.R.T. PLYWOOD. `0UND REDUCING BATT INSULATION (FLAME SPREAD 10, SMOKE DEVELOPED 10). BLANKET FLOORS WITH BRUSHED ALUMINUM COVER 8g5T5PAL. REFER TO ELECTRICAL DRAWING6 O OVER LAYER OF PLYWOOD ONE (I) LAYER FOR MORE INFORMATION. OF 1/4" GYP. BD. ON BOTH SIDES OF GEILIN6 WITH SAME BATT INSULATION 4" TO STUDS. G.G. TO GAP WALL WITH ONE (1) EACH SIDE OF WALL. GA5HWRAP W/ POWER, PHONE 8 DATA LIKES. HEIGHT OF COUNTER TOP TO COMPLY WITH LAYER OF 5/8" GYP. 130. NEW NON -RATED FURRED -OUT WALL a 200316G/AN51 A-117.1 SECTION qO4. REFER TO DETAIL #2 ON SHEET F-l.l FOR MORE NEW NON -RATED FITTING ROOM PARTITION TOI. GOW5TRUGTION. 151b" METAL 5TUD5. ON INFORMATION. 8'-O" A.F.F. (DOOR JAMB WALL5 ONLY). 2 O EXPOSED SIDE OF STUDS ONE (1) LAYER -I 2AIOB6 FIRE EXTINGUISHER PER CODE. 1/2" METAL STUDS e 16' O.G. MAX. WO 5/8' OF 518 GYP. BD. TO ADJACENT CEILING. GYP. BD. EACH SIDE, TOTAL WALL NEW NON -RATED 6" METAL STUD PLUMBING DASHED LINE INDICATES EX15TINO DEMISING WALL TO BE REMOVED. G.G. TO PATCH AND THICKNESS TO ACCOMMODATE WALL CONSTRUCTION. ONE (1) LAYER OF 112" REPAIR ADJACENT WALL AS, NEEDED TO MAINTAIN RATING. REFER TO SHEET A-5.3 FOR PREFABRICATED CUSTOM FITTING ROOM GEMENT BD. TO 4'-q" A.F.F. AND ONE (U EXACT LOCATION. DOOR JAM135 15 3 3/4". ADDITIONAL WALL y D a THICKNESS MAY BE REQUIRED DUE TO DOOR O - LAYER OF 112" GREENBOARD FROM 4'-q" REFER TO ENLARGED FITTING ROOM FLANS ON SHEET A-5.2 FOR INFORMATION O MANUFAGI'URER'5 ACTUAL PRODUCT. A.F.F. TO 3" ABOVE ADJACENT CEILING ON EXPOSED 51DE5 OF 5TUD5. REGARDING ADA COMPLIANCY, PARTITIONS AND ALL FITTING ROOM FIXTURES. SHALL INCLUDE ONE (1) LAYER OF 5/8' PLYWOOD SHEATHING OVER 57UY,--) AS, PART 6.G. TO PROVIDE 1/2" F.R.T. PLYWOOD BLOCKING AT ALL FITTING ROOM INTERIOR WAL.L5 OF BID. 6.G. MUST CONFIRM WITH SHOP f NEW NON -RATED b" METAL STUD PLUMBING IID FOR NEW HOOKS THAT WILL BE MOUNTED ® 5'-0" O.G. IN ALL FITTING ROOMS EXCEPT �� �, WALL CONSTRUCTION. ON EXP05ED SIDES _ I T 4 A.F.F. M MICH E MOUNTED ® 8 R THE ADA FITTING ROO G SHALL B DRAWINGS PRIOR TO GONSTRUGTION FOR FO E ACTUAL WALL THICKNESS REQUIRED, WALL 4 OF STUDS ONE (1) LAYER OF 5/8" GYP. ED, TO RECEIVE GYP. 13D. GAP. TO 3' ABOVE ADJACENT CEILING. PROVIDE POWER FOR 5E( URITY SYSTEM PANEL, IF NOT ALREADY EXISTING. REFER TO 11 NEW FURRED OUT WALL CONSTRUCTION. I NEW NON -RATED 3 5/8" METAL STUD ELECTRICAL DRAWINGS FOR MORE INFORMATION. 5/8" METAL STUDS. ON EXPOSED SIDE OF WALL CON5TRDGTION, ONE (1) LAYER OF 1121 CENTER LINE REFERS TO (ENTER OF DOORS (TYP) F, 5TUD5 ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD 112" GEMENT BD. TO 4'-q" A.F.F. AND ONE TO ADJACENT CEILING. OVER PLYWOOD O `i -' ". (1) LAYER OF 112' 6REENBOARD FROM 13 HOLD COLUMN EN61_05URE A5 CLOSE AS, P055113LE AT STOREFRONT COLUMNS ONLY. ONE (1) LAYER OF 518 GYP. BD TO 4'-q' A.F.F. TO 3' ABOVE ADJACENT ADJACENT CEILING. CEILING ON BOTH SIDES OF 5TUD5. 14 6.G. TO ADD ONE (1) LAYER OF 112' F.R.T. PLYWOOD ON ALL WALL5 OF ELECTRICAL NEW I HOUR -RATED FURRED -OUT WALLROOM AND LAN. ROOM FOR ALL ELEGTRICAL/DATA/ETG. EQUIPMENT. REFER TO CONSTRUCTION. 1 5/8" METAL 5TUD5. ON I I NEW 2 HOUR -RATED 3 518" METAL STUD WALL ELECTRICAL DRAWINGS FOR MORE INFORMATION. OEXPOSED SIDE OF 5TUD5 ONE (I) LAYER CONSTRUCTION, ON BOTH SIDES OF STUDS OF 5O5° TYPE "X" GYP. BD. TO UNDERSIDE ,- TWO (2) LAYERS OF 518" TYPE "X" GYP. F30. IS F.R.T. PLYWOOD BLOGKfNG IN "WALL CSN `i�LAY •A' OA SIDE TO EXTEND TO 12'-O' " TO UNDERSIDE OF DECK ABOVE. G.G. TO A.F.F. OF DECK ABOVE. VERIFY ADJACENT WALL CONSTRUCTION NEW NON -RATED FITTING ROOM PARTITION TYPE AND RATING. EXISTING RAMP AND STAIRS IN E6RE55 CORRIDOR / MALL CONCOURSE. ALL WORM. TO TO 8'-0" A.F.F. 2 112" METAL 5TUD5 ® Ib' I� 13E DONE BY LANDLORD. COORDINATE WITH LANDLORD G.G. O.G. MAX. ON FITTING ROOM CORRIDOR O , SIDE OF STUDS ONE (1) LAYER OF 5/8" GYP. BD. ON FITTING ROOM 51DE OF 5TUD5 ONE (1) LAYER OF 1/4" GYP. 13D. OVER ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD. WALL TO RECEIVE 5/8" GYP. BD. GAP. C' S- I v i y ft i. E i. SCALE: I/W is 1,-0,1 - - NOTE: REFER TO 5HEET5 A-12, A-1.3, AAA, P40 TRUE NORTP A-15 FOR ARCHITECTURAL kIALL DId4aJ5IU6 AND WALL GON5TRUGTION TYPES. G/. FOR: ARGHITEGTUAL GENERAL NOTE: A. TENANT CONTRACTOR SHALL FIELD VERIFY ALL EXI5TING CONDITIONS PRIOR TO 02.0q.Oq START OF CONSTRUCTION / FABRICATION. 6U 8. DIMENSIONS ARE TO FACE OF GYP. BD. WALLS, UNLE55 OTHERWISE NOTED, REFER TO DECOR PLAN, ELEVATIONS AND DETAILS FOR FINISHES. 03.16.0q G, DO NOT 50ALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. 50MIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. i D. G.G. TO INSTALL AND PROVIDE 2AIOB6 FIRE EXTIN6U15HER5. REFER TO THIS SHEET 29110 Inkster Road FOR LOCATIONS. Suite 200 E. ALL WORK SHALL BE IN COMPLIANCE W/ THE ADOPTED LOCAL GODE5, AIA A-210 Southfield, hal 480341 USA CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, RECOGNIZED INDUSTRY 248 355 0890 ` C 5TAWARD6 IN THE AREA, ALL MANUFA6TURER5 RE( OMMENDATION5 AND ALL OTHER APPLICABLE GODE5. 248 355 0895 Fox F. PROVIDE ACCESSIBILITY FOR THE PHY5IGALLY HANDICAPPED. Copyright , ht c 7009 �% G. ALL WOOD, EXCEPT TRIM, TO BE FIRE RETARDANT TREATED. ALL WOOD IN CONTACT KEN NISCH, AIA W/ (ON6RETE OR GONGRETE BLOCK TO BE PRESSURE TREATED. All rights reserved H. G.G. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYHOOD AND OR BLOCKING IN Certification: WALL 5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTACHED FURNI5HIN65, 516NA6E, Qtg LIGHTING. ETC. OF P Q ` J. 6.6. TO INSURE ALL INTERIOR WALL BLOCKING 15 INSTALLED PRIOR TO APPLYING WALL °° b FIN15HE5.'' K. STOREFRONT GLAZING TO BE SAFETY GLASS. ALL EDGES MUST BE GROUND AND oiq POLISHED. -P ANS 6 rui L. G.G. TO COORDINATE AND PROVIDE ACCESS PANELS IN CEILINC75 FOR EXISTING AND NEW VALVES, CONTROLS AND EQUIPMENT. REFER TO 5HEET5 A-2.1, A-2.2, A-23, ANDT.°°��°�°°�E'a� A-2.4 FOR MORE INFORMATION. M. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH W/ NEW FLOORING AT GASHWRAP AND AT FIXTURES W/ POWER 15 5HOWN ON ELECTRICAL SHEETS. N. IT SHALL BE THE 50LE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEST M015TURE CONTENT OF 5U13 FLOOR PRIOR TO IN5TALLATION OF ALL FIN15H FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER Consultants: MANUFAGTURER'5 SPECIFICATIONS. RETAIL DESIGN CONSULTANT O. G.G. SHALL PATCH, REPAIR AND INSTALL NEW FIREPROOFING TO ALL EXISTING / NEW / JGA INC PROP05ED STEEL TO MAINTAIN FIRE -RATING. G.G. TO PROVIDE ALLOWANCE IN BID. 29110 Inkster Road REFER TO COVER SHEET FOR MORE INFORMATION. Suite 200 1 Southfield, MI 48034 USA t P. G.( . TO VERIFY ALL COLUMN LO( ATION5 AND CONDITIONS. NOTIFY ARCHITECT IF 248 355 0890 I THERE ARE ANY DIFFERENCES. 248 355 0895 Fox '' 1 :,.. C .wlghl 0 2009 4CA. kc m ,�9ht- d WWW.)go.com Q. ALL GYP. 131). 5URFAGE5 SHALL BE A LEVEL 5 FINISH PRIOR TO PAINTING. JGA P'r j #: 1-209-057 {. G/. DRAWINGS ISSUED FOR: ❑ programming 10 schematic des. 02.0q.Oq ❑ design dev. 6U ❑ bidding QLp 03.16.0q tu 19 landlord prelim. 02.0q.Oq LU 02.27.N Q•'u 61 V t ro tt U �rS... C:-7 4 ✓ Qtg 6.4+.tu DRAWINGS ISSUED FOR: ❑ programming 10 schematic des. 02.0q.Oq ❑ design dev. ❑ bidding 11 permits 03.16.0q ❑ construction 19 landlord prelim. 02.0q.Oq 0landlord final 02.27.N REVISIONS: Prj. no. 8-20q-012 Drawn RG, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ARCHITECTURAL FLCX R PLAN Sheet no. A saw v l 1/2 "-1-` 1 AR6HITEMRAt 6ENERAL NOTES: A TENANT CONTRACTOR SHALL FIELD VERIFY ALL EXISTING GONDITION5 PRIOR TO START OF CONSTRUCTION / FABRICATION. B. DIMENSIONS ARE TO FACE OF GYP. BD. WALL5, UNLESS OTHERWISE NOTED. REFER TO DECOR PLAN, EI_EVATION5 AND DETAILS FOR FINI5HE5, G. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT TO ARGHITEGT ANY DI56REPANCIE5 FOR CLARIFICATION. D. G.G. TO INSTALL AND PROVIDE 2AIOBG FIRE EXTINGUISHERS. REFER TO THI5 SHEET FOR LOGATION5. E. ALL WORK SHALL BE IN GOMPLIANGE W/ THE ADOPTED LOCAL GODE5, AIA A-210 CONDITIONS OF THE GONTRAGT FOR CONSTRUCTION, REG06NIZED INDI5TRY STANDARDS IN THE AREA, ALL MANUFAGTURER5 RECOMMENDATIONS AND ALL OTHER APPLIGABLE CODE5. F. PROVIDE A6GE5518ILITY FOR THE PHYSICALLY HANDICAPPED. G. ALL WOOD, EXCEPT TRIM, TO BE FIRE RETARDANT TREATED. ALL WOOD IN GONTAGT W/ CONCRETE OR GONGRETE BLOCK TO BE PRESSURE TREATED. H. G.G. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYWOOD AND OR BLOCKING IN WAL L5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTAGHED FURNI5HINC75, 516NA6E, LIGHTING, ETC. A G.G. TO INSURE ALL INTERIOR WALL BLOCKING 15 INSTALLED PRIOR TO APPLYING WALL FINISHES. K. STOREFRONT &LAZING TO BE SAFETY 6LA55. ALL ED6E5 MUST BE GROUND AND POLISHED. L. G.G. TO COORDINATE AND PROVIDE AGCE55 PANELS IN CEILINGS FOR EXISTING AND NEW VALVES, GONTROL5 AND EQUIPMENT. REFER TO SHEETS A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. M. ALL FLOOR ELECTRICAL BOXE5 TO BE INSTALLED FLU5H W/ NEW FLOORING AT GA51-11,,1R.AP AND AT FIXTURES Wf POWER 15 5HOWN ON ELECTRICAL SHEETS. N. IT SHALL BE THE SOLE RE5PON5113ILITY OF THE GENERAL CONTRACTOR TO TEST MOISTURE CONTENT OF SUB FLOOR PRIOR TO INSTALLATION OF ALL FINISH FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER MANUFA.GTURER'5 5PEGIFIGATION5. 0. G.G. SHALL PATCH, REPAIR AND INSTALL NEW FIREPROOFING TO ALL EXISTING / NEW / PROPOSED STEEL TO MAINTAIN FIRE -RATING. 6.G. TO PROVIDE ALLOWANCE IN BID. REFER TO COVER SHEET FOR MORE INFORMATION. P. G.G. TO VERIFY ALL COLUMN LOCATIONS AND GONDITIONS. NOTIFY ARCHITECT IF THERE ARE ANY DIFFERENCES. Q. ALL GYP. BD. SURFACES SHALL BE A LEVEL 5 FIN15H PRIOR TO PAINTING. ARC ITECJURAL NALL TYPE LE6ENID: NOTES: A. REFER TO SHEET A-5.1 FOR WALL SECTIONS URLE55 OTHERWISE NOTED. B. PLYWOOD REQUIRED IN WALL FOR ALL 5ALE5 AREA WALLS WITH STANDARDS. REFER TO 5HEET5 F-12 AND A-5.1 FOR MORE INFORMATION. G. IN ALL A.G.T. CEILING AREAS GYP. BD. TO EXTEND 3' ABOVE ADJACENT CEILING. EX15TINO DEMISING WALL 5TUD5 BY L.L. G.G. SHALL PROVIDE ONE (1) LAYER OF A TYPE 'X" GYP. BD. OVER STUDS TO COMPLY WITH FIRE RATING IF NOT EXISTING. G.G. TO PROVIDE SOUND ATTENUATION INSULATION IN EXISTING DEM151N6 WALLS. NEW I -HOUR RATED WALL CONSTRUCTION. 3 50" METAL STUDS K ONE (1) LAYER OF B 50" TYPE "X' GYP. BD. ON BOTH 51DE5 TO UNDERSIDE OF DECK ABOVE. NEW NON -RATED WALL GON5TRUCTION. 3 51b" METAL STUDS W/ ONE (1) LAYER OF 5/8' GYP. <C> BD. ON EXPOSED SIDE OF 5TUD5. IN ALL A.G.T. CEILING AREAS GYP. BD. 15 TO EXTEND A MIN. OF 3" ABOVE FINISHED CEILING. NEW NDN -RATED 6' METAL STUD WALL CONSTRUCTION. ON BOTH SIDES OF STUDS ONE( O I) LAYER OF 51b" GYP. BD. TO ADJACENT CEILING. NEW NON -RATED FURRED OUT WALL CONSTRUCTION. 151b" METAL STUDS. ON EXP05ED 51DE OF 5TUD5 ONE (1) LAYER - ---- -_», OF 112' F.R.T. PLYWOOD TO b'-0" A.F.F. AND GYP. BD. FILL FROM b' -O" A.F.F. TO ADJACENT GEILIN6. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 51b' GYP. BD. TO ADJACENT CEILING. i A-1-2 ; SCALE, 1/4' = i' -O" �C> 0 NEW NON -RATED 6" METAL STUD WALL NEW NON -RATED FITTING ROOM PARTITION TO NEW NPN -RATED 3 5/b° METAL 5TUD WALL NEW NON -RAPED 3 5l8"TA 5TUD M� L u� CONSTRUCTION. ON 5ALE5 FLOOR 510E OF b'-0" A.F.F. (DOOR JAMB WALLS ONLY). 2 CONSTRUCTION. ON TOILET ROOM 510E OF HALL.( ON5TMTION, ONE (I) LAYER, OF 5TUD5 ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD 1/2 METAL 5TUD5 ® I6 D.G. MAX. W/ 5/8 5TUD5 ONE (1) LAYER OF 112 GEMENT BOARD \ I/2" GEMENT BD. 70 4`-q' A.F.F. ANp ONE I' TO b' -O" A.F.F. AND 6YP. EV, FILL FROM 6YP. BD. EACH SIDE. TOTAL WALL ( TO 4'-q" A.F.F. AND ONE (1) LAYER OF 1/2" I A ° ' 1 " a O () L YER''OF 112 GR_ENBOAkp FFOM b-0 A.F.F. TO ADJACENT GEILIN6. OVER THIGKKE55 TO ACCOMMODATE GREENBOARD FROM 4-q A.F.F. TO 3 a r PLYWOOD AND 6 C YP. BD. FILL, 6.G. TO I PREFABRICATED GUSTOM FITTING ROOM ABOVE ADJACENT CEILING. ON CELL ING ON BTOOTA.F.F. TOT ABOVE ADJACENT INSTALL ONE (1) LAYER OF 5fb' GYP. BD. TO ! DOOR JAM55 15 3 3/4'. ADDITIONAL WALL CORRIDOR/JANITOR'5 GLO5ET 510E OF EILH 51DE5 OF 5TUD5. ADJACENT CEILING. ON WARDROBE FIXTUREO _ THIGKNE55 MAY BE REQUIRED DUE TO DOOR STUDS ONE (1) LAYER OF 51b" GYP. BD. TO 3" NEW 2 HOUR -RATED 3 5/b" METAL 5TUD WALL SIDE OF 5TUD5 ONE (1) LAYER OF 51b" GYP. MANUFACTURERS ACTUAL PRODUCT. G.G. ABOVE ADJACENT GEILIN6. GaNSTR.UGTION. ON BOTH 51PE5 OF 57UP5 BD. TO ADJACENT CEILING. SHALL INCLUDE ONE (1) LAYER OF 5/8," Y TWO (2) LAYERS OF 5fb" TYPE °X" GYP. SD. PLYWOOD 5HEATHIN6 OVER STUDS A5 PART NEW SOUND ATTENUATED MOTO WALL TO UNDER5IDE OF DECK ABOVE. G.G. T NEW NON -RATED 6" METAL STUD STOREFRONT OF BID. G.G. MUST CONFIRM WITH 5HOP CONSTRUCTION. 3 518 METAL 5TUD5 W/ 5/b VERIFY ADJACENT WALL GON5TRUCTION GYP. BD. ON EACH 51DE OF 5TUD5 TO BOTTOM 29110 Inkster Rami ENTRY GRILLE WALL GON5TRUGTION. ON DRAWIN65 PRIOR TO GON5TRUGTION FOR TYPE AND RATING. 130TH 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/b' ACTUAL WALL THICKNESS REQUIRED. WALL OF METAL DECK ABOVE. FILL ALL 5TUD O ----- =-� GYP. BD. TO ADJACENT CEILING. REFER TO TO RECEIVE GYP. BD. CT AP. CAVITIES FULL HEIGHT WITH F113ER6LA55 r Suite 200 �{ 5HEE15 A-4.1 AND A-42 FOR MORE <� 50UND REDUCING BATT INSULATION (FLAME Southfield, MI 48034 USA is INFORMATION AND DETAILS. NEW FURRED OUT WALL CONSTRUCTION. I SPREAD 10, SMOKE DEVELOPED 10). BLANKET 248 355 0890 5/6" METAL STUUS, ON EXPOSED SIDE OF CEILING WITH SAME BATT INSULATION 4" TO NEW NON -RATED 3 5fb' METAL STUD WALL 5TUD5 ONE (1) LAYER OF 112' F.R.T. PLYWOOD EAGH 51DE OF WALL. 248 355 0$95 Fak CONSTRUCTION. ON SIDE OF 5TU95 ADJACENT P ��` TO ADJACENT CEILING. OVER PLYWOOD TO SIDE OF WARDROBE FIXTURE/SALES ONE (1) LAYER OF 5/8" GYP. BD TO NEW NDN -RATED FURRED -OUT WALL FLOOR 510E INSTALL ONE (1) LAYER OF 5/b' ADJACENT CEILING. i I GDN5TRXTION. 150' METAL 5TUD5. ON Copyright @ 2009 GYP. BD. TO ADJACENT GEILIN6. ON SIDE OFO EXPOSED 51DE OF 5TUD5 ONE (1) LAYER KEN NISCH, AIA All rights reserved 5TUD5 ADJACENT TO BACK OF WAP.DROBE NEW !HOUR -RATED FURRED -OUT WALL " GYP, BD. TO ADJACENT CEILING. OF 5/b M _r_GON5TRUCTION. 1 5/b" METAL 5TUD5. ON FIXTURE/FITTING ROOM 51DE INSTALL ONE (1) C_Xt+ Q EXPOSED 510E OF 5TUD5 ONE (1) LAYER Certification: LAYER OF 1l2" F.R.T. PLYWOOD TO 8'-0' A.F.F. EXPOSED NON -RATED b METAL STUD PLUMBING AND GYP. BD, FILL FROM b'-0" AFF. TO I - OF 5/8" TYPE "X" GYP. BD, TO UNDER5IDE WALL GONSTRUGTION. ONE (I) LAYER OF I/2" ADJACENT CEILING. OVER PLYWOOD AND OF DECK ABOVE. GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) GYP. BD. FILL INSTALL ONE (1) LAYER OF 5/b' NEW NON -RATED FITTING ROOM PARTITION O � LAYER OF 112" 6REEN130ARD FROM 4'-q" d�� � r �� +��• � ; " ouooa� Iry GYP. BD. TO ADJACENT GEILIN6. TO 8'-0" A.F.F. 2 1/2" METAL 5TUD5 0 16' A.F.F. TO 3 ABOVE ADJACENT GEILIN6 ON O.G. MAX. ON FITTING ROOM CORRIDOR EXPOSED SIDES OF STUDS. NEW NON -RATED FITTING ROOM PARTITION51PYER Or- TO b' -O" A.F.F. 2 I/2" METAL STUDS W/ BP. E ON F1OF 7TG ROOM SADE 0 5TU05 ONE NEW NDN -RATED b" METAL 5TUD PLUMBING ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD. " , WALL CONSTRUCTION. ON EXPOSED SIDES 0 , (I) LAYER OF 1/4 GYP. BD. OVER ONE (!) UJ ARG �t; , <8> OVER LAYER OF PLYWOOD ONE (U LAYER LAYER OF 112" F.R.T. PLYWOOD. WALL TO ---1 OF STUDS ONE (I) LAYER OF 5/b" GYP. Bp. �� `o OF 1/4" GYP. BD, ON BOTH SIDES OF " TO 3" ABOVE ADJACENT GEILIN6. RECEIVE 5/b GYP. BD. GAP. s 5TUD5. G.G. TO GAP WALL WITH ONE (I) LAYER OF 5 b 6 P. BD. r Consultants: RETAIL DESIGN CONSULTANT JCAc I 29110 Inkster Rood Suite 200 ` 5'-0" 13'-11 1/2' 15'-3 114" 5'-O 5/841 io" Southfield, Ml X8034 USA 1 248 355 0880 A 248 355 0895 Fax y A > An � * ( d �Q www.jgo.corn ,. �u : ,: M »d U A A A Y A W ! �, E JGA Prj 0 1-209-057 _�, w V V vo V v JANITORS r 2-5 5/8 ELECTRICAL GLO5ET iMENS TOILET ROOM X WOMEN'S TOILET ' � � Q ROOM E22HU I E3 E3 46'-4 3/5"01 ' l'-2 5/5" W-2 1/4' 0 10' -II 1/2" 7 1! 1 21 �j MANAGER51 i B o B , O OFFICE 2'-3 3/4" j ; i W' -bo LAN. ROOM o I3' -b" /V �t LOUNGE 5GALE: 1/4' = 1'-0' W ' � URAL ,-N SCALE: 114' = I' -O" g05lb�e ■ on NEW NON -RATED 3 56" METAL STUD WALL © programming CONSTRUCTION. ON EXP05ED 51DE5 OF ® schematic des. STUDS ONE (1) LAYER OF 112" F.R.T. OF PLYWOOD TO 8'-0' A.FF. AND GYP. BD. FILL T FROM b'-0" A.F.F. TO ADJACENT 6EILIN6. FITTING ROOMS OVER PLYWOOD AND GYP. BD. FILL, G.G. TO SALES FLOOR INSTALL ONE (1) LAYER OF 5/b" GYP. BD. TO 9 landlord prelim. ADJACENT CEILING. 9 landlord final NEW FURRED OUT WALL CON5TRUCTION. 3 5/8' METAL 5TUD5. ON EXPOSED 51DE OF C; STUDS ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD _ O- TO ADJACENT CEILING. OVER PLYWOOD - T ONE (1) LAYER OF 5/S" GYP. BD TO 4'-21/6' ADJACENT CEILING. NEW I -HOUR RATED 3 5/b' METAL STUD F WALL GON5TRUGTION. ON BOTH 51DE5 OF F 5TUD5 ONE (1) LAYER OF 51b' TYPE "X" F GYP. 017. TO UNDERSIDE OF DECK. ON O_ 5ALE5 FLOOR SIDE OF STUDS ONLY OVER LAYER OF TYPE "X' GYP. BD. ONE (1) -1318" LAYER OF I/2" F.R.T. PLYWOOD TO 5'-0" A.F.F. AND GPY. BD. FILL FROM b' -O" A.F.F. TO ADJACENT GEILIN6. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. O�w^dy NEW NON -RATED WALL CONSTRUCTION. 3 51b' METAL 5TUD5. ON SALES FLOOR SIDE J OF STUDS INSTALL ONE (1) LAYER OF 1/2" r r O � O F.R.T. PLYWOOD TO b' -O" A.F.F. AND GYP. O BD. FILL FROM 8'-O' A.F.F. TO ADJACENT GEILIN6. OVER PLYWOOD AND GYP. BD. FILL ONE (I) LAYER OF 5/8" GYP. BD. ^ ADJACENT 6EILIN6. ON 5ALE5 DISPLAY WINDOW 51DE OF STUDS INSTALL ONE (1) LAYER OF 112" F.R.T. PLYWOOD TO 12'-0' A.F.F. AND GYP. BD. FILL FROM 12'-0" A.F.F. TO ADJACENT GEILIN6. OVER PLYWOOD AND GYP. OP. FILL ONE (1) LAYER OF 518' GYP. BD. TO ADJACENT GEILIN6. i A-1-2 ; SCALE, 1/4' = i' -O" �C> 0 NEW NON -RATED 6" METAL STUD WALL NEW NON -RATED FITTING ROOM PARTITION TO NEW NPN -RATED 3 5/b° METAL 5TUD WALL NEW NON -RAPED 3 5l8"TA 5TUD M� L u� CONSTRUCTION. ON 5ALE5 FLOOR 510E OF b'-0" A.F.F. (DOOR JAMB WALLS ONLY). 2 CONSTRUCTION. ON TOILET ROOM 510E OF HALL.( ON5TMTION, ONE (I) LAYER, OF 5TUD5 ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD 1/2 METAL 5TUD5 ® I6 D.G. MAX. W/ 5/8 5TUD5 ONE (1) LAYER OF 112 GEMENT BOARD \ I/2" GEMENT BD. 70 4`-q' A.F.F. ANp ONE I' TO b' -O" A.F.F. AND 6YP. EV, FILL FROM 6YP. BD. EACH SIDE. TOTAL WALL ( TO 4'-q" A.F.F. AND ONE (1) LAYER OF 1/2" I A ° ' 1 " a O () L YER''OF 112 GR_ENBOAkp FFOM b-0 A.F.F. TO ADJACENT GEILIN6. OVER THIGKKE55 TO ACCOMMODATE GREENBOARD FROM 4-q A.F.F. TO 3 a r PLYWOOD AND 6 C YP. BD. FILL, 6.G. TO I PREFABRICATED GUSTOM FITTING ROOM ABOVE ADJACENT CEILING. ON CELL ING ON BTOOTA.F.F. TOT ABOVE ADJACENT INSTALL ONE (1) LAYER OF 5fb' GYP. BD. TO ! DOOR JAM55 15 3 3/4'. ADDITIONAL WALL CORRIDOR/JANITOR'5 GLO5ET 510E OF EILH 51DE5 OF 5TUD5. ADJACENT CEILING. ON WARDROBE FIXTUREO _ THIGKNE55 MAY BE REQUIRED DUE TO DOOR STUDS ONE (1) LAYER OF 51b" GYP. BD. TO 3" NEW 2 HOUR -RATED 3 5/b" METAL 5TUD WALL SIDE OF 5TUD5 ONE (1) LAYER OF 51b" GYP. MANUFACTURERS ACTUAL PRODUCT. G.G. ABOVE ADJACENT GEILIN6. GaNSTR.UGTION. ON BOTH 51PE5 OF 57UP5 BD. TO ADJACENT CEILING. SHALL INCLUDE ONE (1) LAYER OF 5/8," Y TWO (2) LAYERS OF 5fb" TYPE °X" GYP. SD. PLYWOOD 5HEATHIN6 OVER STUDS A5 PART NEW SOUND ATTENUATED MOTO WALL TO UNDER5IDE OF DECK ABOVE. G.G. T NEW NON -RATED 6" METAL STUD STOREFRONT OF BID. G.G. MUST CONFIRM WITH 5HOP CONSTRUCTION. 3 518 METAL 5TUD5 W/ 5/b VERIFY ADJACENT WALL GON5TRUCTION GYP. BD. ON EACH 51DE OF 5TUD5 TO BOTTOM 29110 Inkster Rami ENTRY GRILLE WALL GON5TRUGTION. ON DRAWIN65 PRIOR TO GON5TRUGTION FOR TYPE AND RATING. 130TH 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/b' ACTUAL WALL THICKNESS REQUIRED. WALL OF METAL DECK ABOVE. FILL ALL 5TUD O ----- =-� GYP. BD. TO ADJACENT CEILING. REFER TO TO RECEIVE GYP. BD. CT AP. CAVITIES FULL HEIGHT WITH F113ER6LA55 r Suite 200 �{ 5HEE15 A-4.1 AND A-42 FOR MORE <� 50UND REDUCING BATT INSULATION (FLAME Southfield, MI 48034 USA is INFORMATION AND DETAILS. NEW FURRED OUT WALL CONSTRUCTION. I SPREAD 10, SMOKE DEVELOPED 10). BLANKET 248 355 0890 5/6" METAL STUUS, ON EXPOSED SIDE OF CEILING WITH SAME BATT INSULATION 4" TO NEW NON -RATED 3 5fb' METAL STUD WALL 5TUD5 ONE (1) LAYER OF 112' F.R.T. PLYWOOD EAGH 51DE OF WALL. 248 355 0$95 Fak CONSTRUCTION. ON SIDE OF 5TU95 ADJACENT P ��` TO ADJACENT CEILING. OVER PLYWOOD TO SIDE OF WARDROBE FIXTURE/SALES ONE (1) LAYER OF 5/8" GYP. BD TO NEW NDN -RATED FURRED -OUT WALL FLOOR 510E INSTALL ONE (1) LAYER OF 5/b' ADJACENT CEILING. i I GDN5TRXTION. 150' METAL 5TUD5. ON Copyright @ 2009 GYP. BD. TO ADJACENT GEILIN6. ON SIDE OFO EXPOSED 51DE OF 5TUD5 ONE (1) LAYER KEN NISCH, AIA All rights reserved 5TUD5 ADJACENT TO BACK OF WAP.DROBE NEW !HOUR -RATED FURRED -OUT WALL " GYP, BD. TO ADJACENT CEILING. OF 5/b M _r_GON5TRUCTION. 1 5/b" METAL 5TUD5. ON FIXTURE/FITTING ROOM 51DE INSTALL ONE (1) C_Xt+ Q EXPOSED 510E OF 5TUD5 ONE (1) LAYER Certification: LAYER OF 1l2" F.R.T. PLYWOOD TO 8'-0' A.F.F. EXPOSED NON -RATED b METAL STUD PLUMBING AND GYP. BD, FILL FROM b'-0" AFF. TO I - OF 5/8" TYPE "X" GYP. BD, TO UNDER5IDE WALL GONSTRUGTION. ONE (I) LAYER OF I/2" ADJACENT CEILING. OVER PLYWOOD AND OF DECK ABOVE. GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) GYP. BD. FILL INSTALL ONE (1) LAYER OF 5/b' NEW NON -RATED FITTING ROOM PARTITION O � LAYER OF 112" 6REEN130ARD FROM 4'-q" d�� � r �� +��• � ; " ouooa� Iry GYP. BD. TO ADJACENT GEILIN6. TO 8'-0" A.F.F. 2 1/2" METAL 5TUD5 0 16' A.F.F. TO 3 ABOVE ADJACENT GEILIN6 ON O.G. MAX. ON FITTING ROOM CORRIDOR EXPOSED SIDES OF STUDS. NEW NON -RATED FITTING ROOM PARTITION51PYER Or- TO b' -O" A.F.F. 2 I/2" METAL STUDS W/ BP. E ON F1OF 7TG ROOM SADE 0 5TU05 ONE NEW NDN -RATED b" METAL 5TUD PLUMBING ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD. " , WALL CONSTRUCTION. ON EXPOSED SIDES 0 , (I) LAYER OF 1/4 GYP. BD. OVER ONE (!) UJ ARG �t; , <8> OVER LAYER OF PLYWOOD ONE (U LAYER LAYER OF 112" F.R.T. PLYWOOD. WALL TO ---1 OF STUDS ONE (I) LAYER OF 5/b" GYP. Bp. �� `o OF 1/4" GYP. BD, ON BOTH SIDES OF " TO 3" ABOVE ADJACENT GEILIN6. RECEIVE 5/b GYP. BD. GAP. s 5TUD5. G.G. TO GAP WALL WITH ONE (I) LAYER OF 5 b 6 P. BD. r Consultants: RETAIL DESIGN CONSULTANT JCAc I 29110 Inkster Rood Suite 200 ` 5'-0" 13'-11 1/2' 15'-3 114" 5'-O 5/841 io" Southfield, Ml X8034 USA 1 248 355 0880 A 248 355 0895 Fax y A > An � * ( d �Q www.jgo.corn ,. �u : ,: M »d U A A A Y A W ! �, E JGA Prj 0 1-209-057 _�, w V V vo V v JANITORS r 2-5 5/8 ELECTRICAL GLO5ET iMENS TOILET ROOM X WOMEN'S TOILET ' � � Q ROOM E22HU I E3 E3 46'-4 3/5"01 ' l'-2 5/5" W-2 1/4' 0 10' -II 1/2" 7 1! 1 21 �j MANAGER51 i B o B , O OFFICE 2'-3 3/4" j ; i W' -bo LAN. ROOM o I3' -b" /V �t LOUNGE 5GALE: 1/4' = 1'-0' W ' � URAL ,-N SCALE: 114' = I' -O" g05lb�e ■ on FOR: © programming I ® schematic des. 02.0q.0q O design dev. I] bidding � FITTING ROOMS < SALES FLOOR 9 landlord prelim. I 9 landlord final 02.27.01 I C; l Nu - T 5/b 4'-21/6' F F F F F F ~ 21'-7I/b' II' -1318" 24'-l3/b' F lo 57'=10' O�w^dy F J ( r r O � O I O $" t� C) I ;n 2'-0' 2l'-10114' - -- <F> 7- j G yi Ctil � i F F I' 1 3/ ' 3'-4 1/4' I 5ALE-5 FLOOR +D Q ' � J }2,-4a jj.1 I 31A V41 F > <F � F ` � I 8 ,• f + � F I 1 ;} � j � v1 5 -1' -Io i 71-1110' t' -d If" 6-0114' 29-3 V51 I <J� I - -- -------- _ I i A-1-2 ; SCALE, 1/4' = i' -O" �C> 0 NEW NON -RATED 6" METAL STUD WALL NEW NON -RATED FITTING ROOM PARTITION TO NEW NPN -RATED 3 5/b° METAL 5TUD WALL NEW NON -RAPED 3 5l8"TA 5TUD M� L u� CONSTRUCTION. ON 5ALE5 FLOOR 510E OF b'-0" A.F.F. (DOOR JAMB WALLS ONLY). 2 CONSTRUCTION. ON TOILET ROOM 510E OF HALL.( ON5TMTION, ONE (I) LAYER, OF 5TUD5 ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD 1/2 METAL 5TUD5 ® I6 D.G. MAX. W/ 5/8 5TUD5 ONE (1) LAYER OF 112 GEMENT BOARD \ I/2" GEMENT BD. 70 4`-q' A.F.F. ANp ONE I' TO b' -O" A.F.F. AND 6YP. EV, FILL FROM 6YP. BD. EACH SIDE. TOTAL WALL ( TO 4'-q" A.F.F. AND ONE (1) LAYER OF 1/2" I A ° ' 1 " a O () L YER''OF 112 GR_ENBOAkp FFOM b-0 A.F.F. TO ADJACENT GEILIN6. OVER THIGKKE55 TO ACCOMMODATE GREENBOARD FROM 4-q A.F.F. TO 3 a r PLYWOOD AND 6 C YP. BD. FILL, 6.G. TO I PREFABRICATED GUSTOM FITTING ROOM ABOVE ADJACENT CEILING. ON CELL ING ON BTOOTA.F.F. TOT ABOVE ADJACENT INSTALL ONE (1) LAYER OF 5fb' GYP. BD. TO ! DOOR JAM55 15 3 3/4'. ADDITIONAL WALL CORRIDOR/JANITOR'5 GLO5ET 510E OF EILH 51DE5 OF 5TUD5. ADJACENT CEILING. ON WARDROBE FIXTUREO _ THIGKNE55 MAY BE REQUIRED DUE TO DOOR STUDS ONE (1) LAYER OF 51b" GYP. BD. TO 3" NEW 2 HOUR -RATED 3 5/b" METAL 5TUD WALL SIDE OF 5TUD5 ONE (1) LAYER OF 51b" GYP. MANUFACTURERS ACTUAL PRODUCT. G.G. ABOVE ADJACENT GEILIN6. GaNSTR.UGTION. ON BOTH 51PE5 OF 57UP5 BD. TO ADJACENT CEILING. SHALL INCLUDE ONE (1) LAYER OF 5/8," Y TWO (2) LAYERS OF 5fb" TYPE °X" GYP. SD. PLYWOOD 5HEATHIN6 OVER STUDS A5 PART NEW SOUND ATTENUATED MOTO WALL TO UNDER5IDE OF DECK ABOVE. G.G. T NEW NON -RATED 6" METAL STUD STOREFRONT OF BID. G.G. MUST CONFIRM WITH 5HOP CONSTRUCTION. 3 518 METAL 5TUD5 W/ 5/b VERIFY ADJACENT WALL GON5TRUCTION GYP. BD. ON EACH 51DE OF 5TUD5 TO BOTTOM 29110 Inkster Rami ENTRY GRILLE WALL GON5TRUGTION. ON DRAWIN65 PRIOR TO GON5TRUGTION FOR TYPE AND RATING. 130TH 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/b' ACTUAL WALL THICKNESS REQUIRED. WALL OF METAL DECK ABOVE. FILL ALL 5TUD O ----- =-� GYP. BD. TO ADJACENT CEILING. REFER TO TO RECEIVE GYP. BD. CT AP. CAVITIES FULL HEIGHT WITH F113ER6LA55 r Suite 200 �{ 5HEE15 A-4.1 AND A-42 FOR MORE <� 50UND REDUCING BATT INSULATION (FLAME Southfield, MI 48034 USA is INFORMATION AND DETAILS. NEW FURRED OUT WALL CONSTRUCTION. I SPREAD 10, SMOKE DEVELOPED 10). BLANKET 248 355 0890 5/6" METAL STUUS, ON EXPOSED SIDE OF CEILING WITH SAME BATT INSULATION 4" TO NEW NON -RATED 3 5fb' METAL STUD WALL 5TUD5 ONE (1) LAYER OF 112' F.R.T. PLYWOOD EAGH 51DE OF WALL. 248 355 0$95 Fak CONSTRUCTION. ON SIDE OF 5TU95 ADJACENT P ��` TO ADJACENT CEILING. OVER PLYWOOD TO SIDE OF WARDROBE FIXTURE/SALES ONE (1) LAYER OF 5/8" GYP. BD TO NEW NDN -RATED FURRED -OUT WALL FLOOR 510E INSTALL ONE (1) LAYER OF 5/b' ADJACENT CEILING. i I GDN5TRXTION. 150' METAL 5TUD5. ON Copyright @ 2009 GYP. BD. TO ADJACENT GEILIN6. ON SIDE OFO EXPOSED 51DE OF 5TUD5 ONE (1) LAYER KEN NISCH, AIA All rights reserved 5TUD5 ADJACENT TO BACK OF WAP.DROBE NEW !HOUR -RATED FURRED -OUT WALL " GYP, BD. TO ADJACENT CEILING. OF 5/b M _r_GON5TRUCTION. 1 5/b" METAL 5TUD5. ON FIXTURE/FITTING ROOM 51DE INSTALL ONE (1) C_Xt+ Q EXPOSED 510E OF 5TUD5 ONE (1) LAYER Certification: LAYER OF 1l2" F.R.T. PLYWOOD TO 8'-0' A.F.F. EXPOSED NON -RATED b METAL STUD PLUMBING AND GYP. BD, FILL FROM b'-0" AFF. TO I - OF 5/8" TYPE "X" GYP. BD, TO UNDER5IDE WALL GONSTRUGTION. ONE (I) LAYER OF I/2" ADJACENT CEILING. OVER PLYWOOD AND OF DECK ABOVE. GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) GYP. BD. FILL INSTALL ONE (1) LAYER OF 5/b' NEW NON -RATED FITTING ROOM PARTITION O � LAYER OF 112" 6REEN130ARD FROM 4'-q" d�� � r �� +��• � ; " ouooa� Iry GYP. BD. TO ADJACENT GEILIN6. TO 8'-0" A.F.F. 2 1/2" METAL 5TUD5 0 16' A.F.F. TO 3 ABOVE ADJACENT GEILIN6 ON O.G. MAX. ON FITTING ROOM CORRIDOR EXPOSED SIDES OF STUDS. NEW NON -RATED FITTING ROOM PARTITION51PYER Or- TO b' -O" A.F.F. 2 I/2" METAL STUDS W/ BP. E ON F1OF 7TG ROOM SADE 0 5TU05 ONE NEW NDN -RATED b" METAL 5TUD PLUMBING ONE (1) LAYER OF 1/2 F.R.T. PLYWOOD. " , WALL CONSTRUCTION. ON EXPOSED SIDES 0 , (I) LAYER OF 1/4 GYP. BD. OVER ONE (!) UJ ARG �t; , <8> OVER LAYER OF PLYWOOD ONE (U LAYER LAYER OF 112" F.R.T. PLYWOOD. WALL TO ---1 OF STUDS ONE (I) LAYER OF 5/b" GYP. Bp. �� `o OF 1/4" GYP. BD, ON BOTH SIDES OF " TO 3" ABOVE ADJACENT GEILIN6. RECEIVE 5/b GYP. BD. GAP. s 5TUD5. G.G. TO GAP WALL WITH ONE (I) LAYER OF 5 b 6 P. BD. r Consultants: RETAIL DESIGN CONSULTANT JCAc I 29110 Inkster Rood Suite 200 ` 5'-0" 13'-11 1/2' 15'-3 114" 5'-O 5/841 io" Southfield, Ml X8034 USA 1 248 355 0880 A 248 355 0895 Fax y A > An � * ( d �Q www.jgo.corn ,. �u : ,: M »d U A A A Y A W ! �, E JGA Prj 0 1-209-057 _�, w V V vo V v JANITORS r 2-5 5/8 ELECTRICAL GLO5ET iMENS TOILET ROOM X WOMEN'S TOILET ' � � Q ROOM E22HU I E3 E3 46'-4 3/5"01 ' l'-2 5/5" W-2 1/4' 0 10' -II 1/2" 7 1! 1 21 �j MANAGER51 i B o B , O OFFICE 2'-3 3/4" j ; i W' -bo LAN. ROOM o I3' -b" /V �t LOUNGE 5GALE: 1/4' = 1'-0' W ' � URAL ,-N SCALE: 114' = I' -O" g05lb�e ■ on DRAWINGS ISSUED FOR: © programming I ® schematic des. 02.0q.0q O design dev. I] bidding � 19 permits IIi O construction 9 landlord prelim. I 9 landlord final 02.27.01 I lu Nu 6//'��,'•,qy -• 1 ew% 1 O�w^dy J ( I O $" I DRAWINGS ISSUED FOR: © programming I ® schematic des. 02.0q.0q O design dev. I] bidding 19 permits 03.16.Oq O construction 9 landlord prelim. 02.0'x.09 9 landlord final 02.27.01 REVISIONS: Prj. no. -209-012 Drawn RG, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions 'only. Drawing title: ENLARGED I ARCHITECTURAL FLOOR PLANS �I Sheet no. i ii i' [r � ARC H TE(JURAL NALL TYPE LE6END: NOTES: A. REFER TO SHEET A-5.1 FOR WALL 5EGTION5 UNL E55 OTHERWISE NOTED. B. PLYWOOD REQUIRED IN WALL FOR ALL SALES AREA WALL5 WITH STANDARDS. REFER TO SHEETS F-12 AND A-5.1 FOR MORE INFORMATION, G. IN ALL A.G.T. CEILING AREAS GYP. BD. TO EXTEND 3" ABOVE ADJACENT GEILING. EXI5TING DEMISING WALL 5TUD5 BY L.L. G.G. SHALL PROVIDE ONE (1) LAYER OF TYPE "X" GYP. BD. OVER 5TUD5 TO COMPLY OA WITH FIRE RATING IF NOT EXISTING. G.G. TO PROVIDE 50UW ATTENUATION INSULATION IN EXISTING DEMISING WALL5. NEW I -HOUR RATED WALL CONSTRUCTION. 3 5/8" METAL STUDS W/ ONE (1) LAYER OF O 5/8" TYPE "X' GYP. BD. ON BOTH 51DE5 i� TO UNDERSIDE OF DECK ABOVE. NEW NON -RATED WALL CONSTRUCTION. 3 5/8" O<METAL 5TUD5 W/ ONE (1) LAYER OF 5/8" GYP. ; 'i' BD. ON EXPOSED 510E OF STUDS. IN ALL A.G.T. CEILING AREAS GYP. BD. 15 TO EXTEND A MIN. OF 3" ABOVE FINISHED GEILING. L 65'-4 3/S" NEW 1 -HOUR RATED 3 5/8" METAL 5TUD WALL GON5TRUCTION. ON BOTH 5IDE5 OF STUDS ONE (1) LAYER OF 5/8" TYPE "X' GYP. BD. TO UNDERSIDE OF DECK. ON SALES FLOOR 51DE OF 5TUD5 ONLY OVER OLAYER OF TYPE 'X" GYP. BD. ONE (1) _ LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-0" A.F.F. AND GPY. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT GEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT GEILING. NEW NON -RATED WALL GON5TRUCTION. 3 5/8" METAL STUDS. ON 5ALE5 FLOOR 510E OF STUDS INSTALL ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO i3' -O" A.F.F. AND GYP. BD. FILL FROM 6'-0' A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL J ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT GEILING. ON SALES DISPLAY WINDOW 51DE OF 5TUD5 INSTALL ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 12'-0" A.F.F. AND GYP. BD. FILL FROM 12'-0" A.F.F. TO ADJAGENT CEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT CEILING. NF_W NON -RATED b" METAL STUD WALL CONSTRUCTION. ON BOTH SIDES OF STUDS O® ONE (1) LAYER OF 5/b' GYP, BD. TO O = ADJACENT CEILING. O _ NEW NON -RATED FURRED OUT WALL � Q.00000V?a���� CONSTRUCTION. 15/&" METAL STUDS. ON Southfield, MI 48034 USA EXP05ED 51DE OF STUDS ONE (1) LAYER O , _ OF 1/2' F.R.T. PLYWOOD TO 8'-U" A.F.F. iO.G. > - AND GYP. B0. FILL FROM 8'-0' A.F.F. TO www.jgo.com ADJACENT GEILING. OVER PLYWOOD AND 1-209-051 GYP. BD. FILL ONE (1) LAYER OF 5/8" GYP, O BD. TO ADJACENT CEILING. 0 , <\ -�` MEW NON -RATED 3 5/8" METAL 5TUD WALL / GON5TRIJGTION. ON EXPO5ED 51DE5 OF STUDS ONE (I) LAYER OF I/2" F.R.T. PLYWOOD TO 8'-0" A.F.F. AND GYP. BD. FILL OF FROM 8'-0" A.F.F. TO ADJACENT GEILING. -J,i_ O � OVER PLYWOOD AND GYP. BD. FILL, G.G. TO T-------- INSTALL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT GEILING. "i NEW FURRED OUT WALL CONSTRUCTION. 3 qJ-`-" Ty 5/8' METAL 5TUD5. ON EXPOSED SIDE OF . • STUDS ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD O TO ADJACENT CEILING. OVER PLYWOOD ` ONE (1) LAYER OF 5/8 GYP. BD TO ADJACENT GEILING. 65'-4 3/S" NEW 1 -HOUR RATED 3 5/8" METAL 5TUD WALL GON5TRUCTION. ON BOTH 5IDE5 OF STUDS ONE (1) LAYER OF 5/8" TYPE "X' GYP. BD. TO UNDERSIDE OF DECK. ON SALES FLOOR 51DE OF 5TUD5 ONLY OVER OLAYER OF TYPE 'X" GYP. BD. ONE (1) _ LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-0" A.F.F. AND GPY. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT GEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT GEILING. NEW NON -RATED WALL GON5TRUCTION. 3 5/8" METAL STUDS. ON 5ALE5 FLOOR 510E OF STUDS INSTALL ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO i3' -O" A.F.F. AND GYP. BD. FILL FROM 6'-0' A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL J ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT GEILING. ON SALES DISPLAY WINDOW 51DE OF 5TUD5 INSTALL ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 12'-0" A.F.F. AND GYP. BD. FILL FROM 12'-0" A.F.F. TO ADJAGENT CEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT CEILING. ENLARGED A 111T Co.ru L FLOOR PLAN SALE: 114' = 1'-0' 9051tca5& ARCHTEMRAL GENERAL NOTE: A. TE1Wff CONTRA( TOR SHALL FIELD VERIFY ALL EXISTING GONDITION5 PRIOR TO START OF CONSTRUCTION / FABRICATION. B. OIMEI61ON5 ARE TO FACE OF GYP. BO. rIALL5, UNLE55 OTHEP. 115E NOTED. REFER TO DECOR PLAN, ELEVATION5 AND DETAIL5 FOR FIN15HE5. G. DO NOT SCALE THESE DRAWINGS. U5E WRITTEN 9IM&6ION5 ONLY. SUBMIT TO ARCHITECT ANY OIS6REPAlICIE5 FOR GLARIFI( ATION, D. 67,6. TO IN5TALL AND PROVIDE 2AIOBG FIRE EXTING0I5HER5. REFER TO TH15 SHEET FOR LOCATIONS. E. ALL ),ORK SHALL BE 1N COMPLIANCE W THE ADOPTED LOCAL GODE5, AIA A-210 (_ON9ITIO),6 OF THE CONTRACT FOR GON5TRU6TION, RECOGNIZED INDUSTRY 5TANDARD5 1N THE AREA, ALL iAl:ttFALT1ERG REGOK�ENDATIO% ,N1D AUL BOTHER APFUCABLE C09E5. F. _PRS A(_:a'Z%If3ILITY FOP, TIE PHr (,ALLY HA'rVVJ APPES_ G. ALL 1�Y.,00, EXCEPT TRIM, TO BE FIRE RETARDANT TREATED. ALL WOOD IN CONTACT W C011<SRETE OR CONCRETE BLOCK TO BE PRE55'JRE TREATED. H. O.G. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYWOOD AND OR BL Ol IN A ALL5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTACHED FURNI511114675, 516NAGE, LIGHTING, ETC,. 1 Gj'. TO IW))RE ALL INTERIOR WALL BLOCKING 15 INSTALLED PRIOR TO APPLYING Y4AL.L F IN15HE5. K. STOREFRONT GLAZING TO BE SAFETY 6LA55. ALL EDGE5 MU5T BE GROUND AND POLISHED. L. GL. TO COORDINATE AND PROVIDE A66E55 PANELS IN GEILINC75 FOR EX15TING AND NEVI VALVES, GONTROL5 AND EQUIPMENT. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. M_ ALL FLOOR ELEGTRIGAL 130XE5 TO BE INSTALLED FLUSH W/ NEW FLOORING AT CA5MRAP AND AT FIXTURE5 W POWER 15 SHOWN ON ELEGTRIGAL 5HEET5, N. IT 5HALL 13E THE SOLE RE5PON51BILITY OF THE GENERAL CONTRACTOR TO TEST M015TURE CONTENT OF JIB FLOOR PRIOR TO INSTALLATION. "OF ALL FIN154 FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER MANUFACTURERS SPECIFICATIONS. 0. 6L. SHALL PATCH, REPAIR AND IN5TALL NEW FIREPROOFING TO ALL EXISTING / NEW / PROP05ED 5TEEL TO MAINTAIN FIRE -RATING. G.G. TO PROVIDE AI_LOWANGE IN 810. REFcR TO COVER 5hEET FOR MORE INFORMATION. P. &L. TO VERIFY ALL COLUMN .LOCATIONS AND GONDITIUN5. NOTIFY ARCHITECT IF THERE ARE ANY DIFFEEREN6E5. a ALL 6YP.W %RFAGE5 Si 1ALI L BE A LEVEL 5 FINISH PRIOR TO PAINTING. NEW NON -RATED b" METAL STUD WALL a CONSTRUCTION. ON SALES FLOOR 510E OF O = 5TUD5 ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD O _ TO 8'-0' A.F.F. AND GYP. BD. FILL FROM 8'-O" A.F.F. TO ADJACENT CEILING. OVER � Q.00000V?a���� PLYWOOD AND GYP. BD. FILL, G.G. TO Southfield, MI 48034 USA INSTALL ONE (1) LAYER OF 5/8' GYP. BD. TO 248 355 0890 ADJACENT CEILING. 0N WARROBEFIXIUR E iO.G. > - SIDE OF STUDS ONE (1) LAYER OF 5/8" GYP. www.jgo.com BO. TO ADJACENT CEILING. 1-209-051 NEW NON -RATED b" METAL STUD STOREFRONT O ENTRY GRILLE WALL GON5TRUGTION. ON BOTH 510E5 OF STUDS ONE (I) LAYER OF 5/8" 0 , <\ -�` GYP. BD. TO ADJACENT CEILING. REFER TO / SHEETS A-4.1 AND A-42 FOR MORE INFORMATION AND DETAILS. NEW NON -RATED 3,50' METAL 5TUD WALL -J,i_ O � GON5TRUCTION. ON 515E OF STUDS ADJAGENT T-------- TO 510E OF WARDROBE FIXTURE/5ALE5 FLOOR 51DE INSTALL ONE (1) LAYER OF 5/8" "i 6YP. BD. TO ADJACENT CEILING. ON 51DE OF qJ-`-" Ty NEW FURRED OUT WALL CONSTRUCTION. I STUDS ADJACENT TO BACK OF WARDROBE O TO ADJACENT GEILING. OVER PLYWOOD ` FIXTURE/FITTING ROOM SIDE INSTALL ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-0" A.FF, AND GYP. BD. FILL FROM 8'-0' A.F.F. TO ADJAGENT GEILING. OVER PLYWOOD AND GYP. BD. FILL INSTALL ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT CEILING. ENLARGED A 111T Co.ru L FLOOR PLAN SALE: 114' = 1'-0' 9051tca5& ARCHTEMRAL GENERAL NOTE: A. TE1Wff CONTRA( TOR SHALL FIELD VERIFY ALL EXISTING GONDITION5 PRIOR TO START OF CONSTRUCTION / FABRICATION. B. OIMEI61ON5 ARE TO FACE OF GYP. BO. rIALL5, UNLE55 OTHEP. 115E NOTED. REFER TO DECOR PLAN, ELEVATION5 AND DETAIL5 FOR FIN15HE5. G. DO NOT SCALE THESE DRAWINGS. U5E WRITTEN 9IM&6ION5 ONLY. SUBMIT TO ARCHITECT ANY OIS6REPAlICIE5 FOR GLARIFI( ATION, D. 67,6. TO IN5TALL AND PROVIDE 2AIOBG FIRE EXTING0I5HER5. REFER TO TH15 SHEET FOR LOCATIONS. E. ALL ),ORK SHALL BE 1N COMPLIANCE W THE ADOPTED LOCAL GODE5, AIA A-210 (_ON9ITIO),6 OF THE CONTRACT FOR GON5TRU6TION, RECOGNIZED INDUSTRY 5TANDARD5 1N THE AREA, ALL iAl:ttFALT1ERG REGOK�ENDATIO% ,N1D AUL BOTHER APFUCABLE C09E5. F. _PRS A(_:a'Z%If3ILITY FOP, TIE PHr (,ALLY HA'rVVJ APPES_ G. ALL 1�Y.,00, EXCEPT TRIM, TO BE FIRE RETARDANT TREATED. ALL WOOD IN CONTACT W C011<SRETE OR CONCRETE BLOCK TO BE PRE55'JRE TREATED. H. O.G. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYWOOD AND OR BL Ol IN A ALL5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTACHED FURNI511114675, 516NAGE, LIGHTING, ETC,. 1 Gj'. TO IW))RE ALL INTERIOR WALL BLOCKING 15 INSTALLED PRIOR TO APPLYING Y4AL.L F IN15HE5. K. STOREFRONT GLAZING TO BE SAFETY 6LA55. ALL EDGE5 MU5T BE GROUND AND POLISHED. L. GL. TO COORDINATE AND PROVIDE A66E55 PANELS IN GEILINC75 FOR EX15TING AND NEVI VALVES, GONTROL5 AND EQUIPMENT. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. M_ ALL FLOOR ELEGTRIGAL 130XE5 TO BE INSTALLED FLUSH W/ NEW FLOORING AT CA5MRAP AND AT FIXTURE5 W POWER 15 SHOWN ON ELEGTRIGAL 5HEET5, N. IT 5HALL 13E THE SOLE RE5PON51BILITY OF THE GENERAL CONTRACTOR TO TEST M015TURE CONTENT OF JIB FLOOR PRIOR TO INSTALLATION. "OF ALL FIN154 FLOORING MATERIALS AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER MANUFACTURERS SPECIFICATIONS. 0. 6L. SHALL PATCH, REPAIR AND IN5TALL NEW FIREPROOFING TO ALL EXISTING / NEW / PROP05ED 5TEEL TO MAINTAIN FIRE -RATING. G.G. TO PROVIDE AI_LOWANGE IN 810. REFcR TO COVER 5hEET FOR MORE INFORMATION. P. &L. TO VERIFY ALL COLUMN .LOCATIONS AND GONDITIUN5. NOTIFY ARCHITECT IF THERE ARE ANY DIFFEEREN6E5. a ALL 6YP.W %RFAGE5 Si 1ALI L BE A LEVEL 5 FINISH PRIOR TO PAINTING. .:.I Aw rM a i -.rig, T L. � - A PLAN SCALE: 1/4" = 1'-0' g051ba5e NEW NON -RATED FITTING ROOM PARTITION a TO 8'-0" A.F.F. 2 1/2" METAL STUDS NU O = ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD. OVER LAYER OF PLYWOOD ONE (1) LAYER OF 1/4" GYP. W. ON BOTH SIDES OF T STUDS. 6.6, TO GAP WALL WITH ONE (1) � Q.00000V?a���� LAYER OF 5/8" GYP. BD. Southfield, MI 48034 USA NEW NONRATED FITTING ROOM PARTITION TO 248 355 0890 8'-0" A.F.F. (DOOR JAMB WALL5 ONLY). 2 iO.G. > - 1/2' METAL 5TUD5 0 I b' O.G. MAX. W/ 5/8' www.jgo.com GYP. 130. EACH SIDE. TOTAL WALL 1-209-051 THIGKNE55 TO ACCOMMODATE O PREFABRICATED CUSTOM FITTING ROOM 0 , <\ -�` DOOR JAM55 15 3 3/4". ADDITIONAL WALL THIGKNE55 MAY BE REQUIRED DUE TO DOOR / MANUFAGTURER'5 ACTUAL PRODUCT. G.G. SHALL INCLUDE ONE (1) LAYER OF 5/8" PLYWOOD SHEATHING OVER STUDS A5 PART -J,i_ O � OF BID. G.G. MUST CONFIRM WITH SHOP T-------- DRAWING5 PRIOR TO GON5TRUCTION FOR ACTUAL WALL THICKNESS REQUIRED. WALL "i TO RECEIVE GYP. BD. GAP. qJ-`-" Ty NEW FURRED OUT WALL CONSTRUCTION. I 5/8" METAL STUDS, ON EXPOSED 51DE OF STUDS ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD O TO ADJACENT GEILING. OVER PLYWOOD ONE (1) LAYER OF 5/8" GYP. BD TO ADJACENT CEILING. .:.I Aw rM a i -.rig, T L. � - A PLAN SCALE: 1/4" = 1'-0' g051ba5e NEI^l I HOUR -RATED FURRED -OUT WALL a CONSTRUCTION. 15/I5 METAL STUDS. ON O - EXPOSED SIDE OF 5TUD5 ONE (I) LAYER T OF 5/0' TYPE "X" GYP. BD. TO UNDER5IDE � Q.00000V?a���� OF DECK ABOVE. Southfield, MI 48034 USA NEW NON -RATED FITTING ROOM PARTITION 248 355 0890 TO 8'-0" A.F.F. 2 I/2" METAL STUDS @ 16" iO.G. > - MAX. ON FITTING ROOM CORRIDOR SIDE OF 5TUD5 ONE (1) LAYER OF 5/8" GYP. www.jgo.com BD. ON FITTING ROOM SIDE OF STUDS ONE 1-209-051 (1) LAYER OF 1/4" GYP. BD. OVER ONE (1) O LAYER OF 1/2" F.R.T. PLYWOOD. WALL TO RECEIVE 5/8" GYP. BD. GAP. NEW NON -RATED 3 5/B" METAL STUD WALL CONSTRUCTION. ON TOILET ROOM 510E OF STUDS ONE (I) LAYER OF I/2' GEMENT BOARD -J,i_ O � TO 4'-q' A.F.F. AND ONE (1) LAYER OF 1/2' 6REENBOARD FROM 4'-q" A.FF. TO 3" T-------- ABOVE ADJACENT GEILING. ON GORRIDOR/JANITOR'S GL O5ET 51DE OF "i STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" qJ-`-" Ty ABOVE ADJACENT CEILING. .:.I Aw rM a i -.rig, T L. � - A PLAN SCALE: 1/4" = 1'-0' g051ba5e NEW SOUND ATTENUATED NON -RATED WALL a U 4 5 8 METAL T CONSTRUCTION.3 / E AL 5 UD5 W/ 5/8 O GYP. BD. ON EACH 510E OF STUDS TO BOTTOM T OF METAL DECK ABOVE. FILL ALL 5TUD GAVITIE5 FULL HEIGHT WITH FIBERGLASS � Q.00000V?a���� SOUND REDUCING BATT INSULATION (FLAME Southfield, MI 48034 USA SPREAD 10, SMOKE DEVELOPED 10). BLANKET 248 355 0890 CEILING WITH SAME BATT INSULATION 4" TO 248 3550895 Fax. EACH 51DE OF WALL. www.jgo.com NEW NON -RATED FURRED -OUT WALL 1-209-051 CONSTRUCTION. 156" METAL 5TUD5..; ON O EXP05ED 51DE OF 5TUD5 ONE (1) LAYER OF 5/8' GYP. BD. TO ADJACENT CEILING. NEW NON -RATED b' METAL STUD PLUMBING WALL CONSTRUCTION. ONE (1) LAYER OF 1/2" GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) LAYER OF 1/2' OREENBOARD FROM 4'-q" A.F.F. TO 3' ABOVE ADJACENT GEILING ON EXP05ED 51DE5 OF 5TUD5. "i NEW NUN -RATED b' METAL 5TUD PLUMBING WALL GON5TRU(TION. ON EXPOSED 51DE5 qJ-`-" Ty OF 5TUD5 ONE (1) LAYER OF 5/8" GYP. BD. TO 3" ABOVE ADJACENT CEILING. .:.I Aw rM a i -.rig, T L. � - A PLAN SCALE: 1/4" = 1'-0' g051ba5e Consul tonts: a � O 47 b � d oo hni�li 5U4d S � Q.00000V?a���� °°° % Southfield, MI 48034 USA i Consul tonts: RETAIL DESIGN CONSULTANT { JGA w 29110 Inkster Road Suite 200 } Southfield, MI 48034 USA i 248 355 0890 248 3550895 Fax. wvA.ht .0 20W acp. mo w'tet-.d www.jgo.com JGA Pr j : 1-209-051 SCALE: 1/4" = I'-0' g051ba5e "-1 j: 1I1 I, j, i i i j. DRAWINGS ISSUED FOR: O programming N schematic des. 02.0q.Oq O design dev. ❑ bidding ®permits 03.16.00I ❑ construction . N landlord prelim. 02.0q.Oq N landlord final 02.27.0q i REVISIONS: I: I i i Prj. no. 8-20q-012 'i Drawn RC, Tk4 Checked ALS Approved KN Do not scale this print Use figured dimensions only. Drawing title: ; ENLARGED ARCHITECTURAL i FLOOR PLAN Sheet no. �I. sum I f AR6H I TE6TURAL 1NALL TYPE LEGEND: NOTES: A. REFER TO SHEET A-5.1 FOR WALL 5EGTION5 UNLESS OTHERWISE NOTED. B. PLYWOOD REOIIRED IN WALL FOR ALL SALES AREA WALLS WITH STANDARDS. REFER TO 5HEET5 F-12 AND A-5.1 FOR MORE INFORMATION. G. IN ALL A.G.T. GEILING AREAS GYP. BD. TO ,EXTEND 3" ABOVE ADJACENT CEILING. EX15TING DEM151NG WALL STUDS BY L.L. A�G.G. SHALL PROVIDE ONE (1) LAYER OF TYPE "X" GYP. BD. OVER STUDS TO COMPLY WITH FIRE RATING IF NOT EXI5TIN67. G.G. TO PROVIDE SOUND ATTENUATION INSULATION IN EXISTING DEMISING WALLS. NEW I -HOUR RATED WALL GON5TRUGTION. OE3 3 5/8" METAL 5TUD5 W/ ONE (1) LAYER OF ` � 5/8" TYPE 'X' GYP. BD. ON BOTH 51DE5 TO UNDERSIDE OF DECK ABOVE. NEW NON -RATED WALL CONSTRUCTION. 3 5/8' METAL 5TUD5 W ONE (1) LAYER OF 5/8" GYP. BD. ON EXP05ED 51DE OF 5TUD5. IN ALL A.G.T. GEILING AREAS GYP. BD. 15 TO EXTEND A MIN. OF 3" ABOVE FINISHED GEILING. �NEW f NON -RATED b" METAL STUD WALL GONSTRUGTION, ON BOTH 51DE5 OF STUDS © O ` ONE I LAYER OF5/ 8 GYP. . T G BD O Q _ ADJACENT CEILING. 7 _ O NEW NON -RATED FURRED OUT WALL 0 bidding CONSTRUCTION. 1 518" METAL STUDS. ON E--- .�1, EXP05ED SIDE OF 5TUD5 ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-0" A.FF. AND GYP. BD. FILL FROM 8'-O' A.F.F. TO O construction ADJACENT GEILING. OVER PLYWOOD AND <� GYP. BD. FILL ONE (1) LAYER OF `5/8' •9YP. 11landlord final BD. TO ADJAGENT CEILING. NEW NDN -RATED 3 5/8" METAL 5TUD WALL O GON5TRUGTION. ON EXPOSED SIDES OF STUDS ONE (I) LAYER OF 1/2" F.R.T. OF PLYWOOD TO 8'-D" A.F.F. AND GYP. BD. FILL FROM 8'-O" A.F.F. TO ADJACENT GEILING. OVER PLYWOOD AND GYP. BD. FILL, 6.G. TO INSTALL ONE (1) LAYER OF 51B' GYP_ BD. TO _ ADJACENT CEILING. TO 4'-q" A.F.F. AND ONE (1) LAYER OF I/2' 6REEN130AR-0 FROM 4'-q" A.F.F. TO 3" NEW FURRED OUT WALL CONSTRUCTION. 3 518" METAL 5TUD5, ON EXPOSED SIDE OF O GYP. BD. TO ADJACENT CEILING. ON 51DE OF STUDS ONE (1) LAYER OF 112" F.R.T. PLYWOOD 5TUD5 ADJACENT TO BACK OF WARDROBE ` TO ADJACENT GEILING. OVER PLYWOOD STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" ONE (1) LAYER OF 518" GYP. BD TO ABOVE ADJACENT CEILING. ADJACENT CEILING. NEW I -HOUR RATED 3 518" METAL 5TUD WALLN T T GO 5 RUG ION. ONBO TH SIDES O F 5 5TUD5 ONE (1) LAYER OF 5/8" TYPE "X' GYP. BD. TO UNDERSIDE OF DECK. ON 5ALE5 FI.00R.5.I0E.QF 5WQ5 ONLY.DVER. LAYER OF TYPE "X" GYP. BD. ONE (1) • LAYER OF I/2 F.R.T. PLYWOOD TO &'-0" A.F.F. AND GPY. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND 6YP. BD. FILL ONE (1) LAYER OF 518" GYP. BD. TO ADJACENT CEILING. NEW NON -RATED WALL CONSTRUCTION. 3 5/8" METAL 5TUD5. ON 5ALE5 FLOOR 51DE OF STUDS INSTALL ONE (1) LAYER OF 112" F.R.T. PLYWOOD TO 8'-O" A.F.F. AND GYP. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT GEILING. OVER PLYWOOD AND GYP. BD. FILL �`— j, ONE (1) LAYER OF 518" GYP. BD. TO k_ ADJACENT GEILING. ON SALES DISPLAY WINDON 51DE .OF STUDS INSTALL. ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 12'-0" A.F.F. AND GYP. BD. FILL FROM 12'-O" A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL ONE (1) LAYER OF 518' GYP. BD. TO ADJACENT CEILING. 2 ENLARGE ARCHITECTURAL FLOOR PLAN A-19 9AI..E: 1/4' = 1'-0' g0557bmc NEW NON -RATED FITTING ROOM PARTITION TO 6-0' A.F.F. 2 1/24 METAL 5TUD5 W/ ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD. N I OVER LAYER OF PLYWOOD ONE (1) LAYER " 5TUD5. &L. TO GAP WALL WITH ONE (1) LAYER OF 518" 6YP. BD. NEW NOM -RATED FITTING ROOM PARTITION TO 8'-0' A.F.F. (DOOR JAMB WALLS ONLY). 2 1/2' METAL 5TUD5 0 16' O.G. MAX. W/ 5/b' (5YP. B'D.'EAGH SIDE. 10TAL WALL THIGKNE55 TO ACCOMMODATE PREFABRICATED GUSTOM FITTING ROOM DOOR JAMB5 15 3 3/4". ADDITIONAL WALL O - THIGKNE55 MAY BE REQUIRED DUE TO DOOR MANUFAGTURER15 ACTUAL PRODUCT. G.G. SHALL INCLUDE ONE (1) LAYER OF 5/8" PLYWOOD 5HEA"1'HIN6 OVER 5TUD5 A5 PART OF BID, G.G. MUST CONFIRM WITH SHOP DRAWII5 PRIOR TO GONSTRUGTIOM FOR AGTUAL WALL THICKNESS REOIJIRED, WALL TO RECEIVE GYP. BD. GAP. NEW FURRED OUT WALL CON5TRUGTION. I 5/8" METAL STUDS, ON EXPOSED SIDE OF P, 5TU05 ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO ADJACENT GEILING. OVER PLYWOOD ONE (1) LAYER OF 5/8" GYP. BD TO ADJACENT GEILING, NEW NON -RATED b" METAL STUD WALL ❑ programming N CONSTRUCTION.O SALES FLOOR SIDE 0F Q _ 5TUD5 ONE (1) LAYER OF 112" F.R.T. PLYWOOD 7 _ O TO 8'-0' A.F.F. AND GYP. BD, FILL FROM 8'-0' A.F.F. TO ADJACENT CEILING. OVER 0 bidding PLYWOOD 00 AND GYP. . BD. FILL O.G. T G 0 IN permits INSTALL ONE (1) LAYER OF 5/8' GYP. BD. TO O construction ADJACENT CEILING. ON WARDROBE FIXTURE <� SIDE OF 5TUD5 ONE (1) LAYER OF 518" GYP. 11landlord final BD. TO ADJACENT GEILING. NEW NON -RATED V METAL STUD STOREFRONT O ENTRY GRILLE WALL CONSTRUCTION. ON BOTH SIDES OF 5TUD5 ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT GEILING. REFER TO 5HEET5 A-4.1 AND A-4.2 FOR MORE INFORMATION AND DETAILS. NEW NON -RATED 3 5/8" METAL STUD WALL _ CONSTRUCTION. ON SIDE OF 5TUD5 ADJACENT TO 4'-q" A.F.F. AND ONE (1) LAYER OF I/2' 6REEN130AR-0 FROM 4'-q" A.F.F. TO 3" TD ,511E .OF WAI ROBE FIXTURE/5ALE5 FLOOR 51DE INSTALL ONE (1) LAYER OF 518" GYP. BD. TO ADJACENT CEILING. ON 51DE OF ABOVE ADJAGENT CEILING. ON 5TUD5 ADJACENT TO BACK OF WARDROBE O FIXTURE/FITTING ROOM SIDE INSTALL ONE (1) STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-0" A.F.F. ABOVE ADJACENT CEILING. AND GYP. BD. FILL FROM 8'-0' A.F.F. TO ADJACENT CEILING. OVER PLYWOOD AND GYP. BD. FILL INSTALL ONE (1) LAYER OF 5/8" GYP. BD. TO ADJACENT CEILING. 2 ENLARGE ARCHITECTURAL FLOOR PLAN A-19 9AI..E: 1/4' = 1'-0' g0557bmc NEW NON -RATED FITTING ROOM PARTITION TO 6-0' A.F.F. 2 1/24 METAL 5TUD5 W/ ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD. N I OVER LAYER OF PLYWOOD ONE (1) LAYER " 5TUD5. &L. TO GAP WALL WITH ONE (1) LAYER OF 518" 6YP. BD. NEW NOM -RATED FITTING ROOM PARTITION TO 8'-0' A.F.F. (DOOR JAMB WALLS ONLY). 2 1/2' METAL 5TUD5 0 16' O.G. MAX. W/ 5/b' (5YP. B'D.'EAGH SIDE. 10TAL WALL THIGKNE55 TO ACCOMMODATE PREFABRICATED GUSTOM FITTING ROOM DOOR JAMB5 15 3 3/4". ADDITIONAL WALL O - THIGKNE55 MAY BE REQUIRED DUE TO DOOR MANUFAGTURER15 ACTUAL PRODUCT. G.G. SHALL INCLUDE ONE (1) LAYER OF 5/8" PLYWOOD 5HEA"1'HIN6 OVER 5TUD5 A5 PART OF BID, G.G. MUST CONFIRM WITH SHOP DRAWII5 PRIOR TO GONSTRUGTIOM FOR AGTUAL WALL THICKNESS REOIJIRED, WALL TO RECEIVE GYP. BD. GAP. NEW FURRED OUT WALL CON5TRUGTION. I 5/8" METAL STUDS, ON EXPOSED SIDE OF P, 5TU05 ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO ADJACENT GEILING. OVER PLYWOOD ONE (1) LAYER OF 5/8" GYP. BD TO ADJACENT GEILING, NEW 5OUND ATTENUATED NON-RATED'WALL NEW NON -RATED 3 5/a" METAL 5TUD t. CONSTRUCTION. 3 5/8 METAL STUD5 W/ %b" i WALL 60N6TRUGTION; ONE "(1) LAYER OF GYP. N H , 6 . BD. 0 EAG I F 5 DE 0 STUDS T 0 BOTT M �., •, ' 2 N r, '. I/ CEMENT BD. TO 4 -q A.F.F, AND ONE OF METAL DECK ABOVE. FILL ALL 57UD . = I LAYER OF I R O O /2 G EENBOARD FROM i GAVITIES FULL HEIGHT WITH FIBERGLASS - AF.F.T031 ABOVE D A GENT aL :5 5OUND REDUCING BATT (FL INSULATION (FLAME ME CEILING ON BOTH 51f7E5 OF STUDS., SPREAD 10, SMOKE DEVELOPED 10). BLANKET GEILING WITH SAME BATT INSULATION 4" TO NEW 2 HOUR -RATED 3 5/8" METAL STUD WALL ? i EAG H SIDE OF WALL. ( CON5TRIX TION. ON BOTH SIDES OF 5TUD5 I TWO (2) LAYERS OF 5/8' TYPE 'X" GYP. BD. A NEW NON -RATED FURRED -OUT WALL TO UNDERSIDE i1.1 O OF DECK ABOVE. G.G. TO OCONSTRUCTION. 15/5" METAL STUDS. ON VERIFY ADJAGENT WALL CONSTRUCTION f �----� EXPOSED SIDE OF 5TUD5 ONE (1) LAYER TYPE AND RATING. 29110 Inkster Road. OF 5/6' GYP. BD, TO ADJACENT GEILING. NEW NON -RATED 6' METAL STUD PLUMBING WALL CONSTRUCTION. ONE (I) LAYER OF I/2" OV f GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) I----- LAYER OF 1/2" 6REENWAR-0 FROM 4'-q" A.F.F. TO 3" ABOVE ADJACENT CEILING ON EXPOSED SIDES OF 5TUD5. NEW NON -RATED 6' METAL STUD PLUMBING WALL GON5TRUGTION. ON EXP05EP 51DE5 OF STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" ABOVE ADJACENT CEILING. SCALE: 1/4" = I'-0" ARGHITEGT RAL 6ENERAL Nc T . A. TENANT CONTRACTOR SHALL FIELD VERIFY ALL EXI5TIN6 CONDITIONS PRIOR TO START OF CONSTRUCTION / FABRICATION. B. DIMENSIONS ARE TO FACE OF GYP. BD. WALLS, UNLE550THERWI5E NOTED. REFER TO DECOR PLAN, ELEVATIONS AND DETAILS FOR FINISHES. G. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMLN510% ONLY. SUBMIT TO ARGHITEGT ANY 1)156REPANGIE5 FOR GLARIFIGATION. D. G.G. TO INSTALL AND PROVIDE 2AIOBG FIRE EXTINGUISHERS. REFER TO TH15 SHEET FOR LOCATION5. E. ALL WORK SHALL BE IN COMPLIANCE W/ THE ADOPTED LOCAL CODES, AIA A-210 6ONDITION5 OF THE CONTRACT FOR GON5TPJY TION, RECOGNIZED INDUSTRY 5TANDARD5 IN THE AREA, ALL MANUFACTURERS RECOMMENDATIONS AND ALL OTHER APPLICABLE CODES. F. PROVIDE ACCESSIBILITY FOR THE PHY516ALLY HANDICAPPED. -'&,ALL 4.1OD,-EXGEPT-TRIM,-TO BE FIRE •RETARD,ANT,T-RFAT'FP. 09WACT W/ CONCRETE OR GON6RETE BL06K TO BE PRESSURE TREATED. t, 6L. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYWOOD AND OR BLOGKIN6 IN k0_1 L5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTACHED FURNl5I1ff466, SIGNAGE, LI&WiN6, FTG. ARCHITECTURAL. •GENERAL NOTES GONTINUED: J. G.G. TO INSURE ALL INTERIOR WALL BLOGKING 15 IN5TALLED PRIOR TO APPLYING WALL FINISHES. K. STOREFRONT GLAZING TO BE SAFETY GLASS. ALL ED6E5 MUST BE GROUND AND POLISHED. L. G.G. TO COORDINATE AND PROVIDE AGGE55 PANELS IN GEILINGS FOR EXISTING AND NEW VALVES, WNTROL5 AND EQUIPMENT. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. M. ALL FLOOR ELECTRICAL BOXE5 TO BE INSTALLED FLUSH W/ NEW FLOORING AT GA5HWRAP AND AT FIXTURES W/ POWER 15 SHOWN ON ELECTRICAL SHEETS. N. IT SHALL BE THE 50LE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEST MOISTURE CONTENT OF 5013 FLOOR PRIOR TO INSTALLATION OF ALL FIN15H FLOORING NIATERIAL5 AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER MANUFA6TURER'5 5PEGIFIGATION5. D. G.G. SHALL PATCH, REPAIR AND INSTALL NEW FIREPROOFING TO ALL EXI5TIN65 / NEW / ,FROP05ED ,TEEL TO MAINTAIN FHRE-RRATIN6. • •F.G. TO PROVIDE ALLOWANCE IN 1319. REFER TO COVER SHEET FOR MORE INFORMATION. P. G.G. TO VERIFY ALL COLUMN LOGATION5 AND CONDITIONS. NOTIFY ARGHITEGT IF THERE ARE ANY DIFFERENCES. Q. ALL GYP. BD. SURFACES SHALL BE A LEVEL 5 FIN15H PRIOR TO PAINTING. Suite 200 s Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Copyright `C 2008 j KEN NISCH, AIA All rights reserved Certification:'' 11 1.1 i' Consultants - RETAIL DESIGN CONSULTANT 71 JGA Inc 29110 Inkster Rood Suite 200, Southfield, Ml 48034 USA w 248 355 0890 248 355 0895 fax AN .; /' ,._« �, www.jgo.com JGA Pr j #: 1-209-057 ,. DRAWINGS ISSUED NEW I HOUR -RATED FURRED -OUT WALL ❑ programming CONSTRUCTION. 15/8" METAL STUDS. ON Q _ EXPOSED 51DE OF STUDS ONE (1) LAYER El design dev. OF 5/8 " TYPE X" GYP. BD. TO UNDERSIDE 0 bidding OF DECK ABOVE. IN permits NEW NON -RATED FITTING ROOM PARTITION O construction TO 8'-0" A.F.F. 2 1/2" METAL 5TUD5 @ 16" <� O.G. MAX. ON FITTING ROOM CORRIDOR SIDE OF STUDS ONE (1) LAYER OF 5/8" GYP. 11landlord final BD. ON FITTING ROOM 51DE OF 5TU05 ONE (1) LAYER OF 1/4" GYP. BD. OVER ONE (1) LAYER OF 112" F.R.T. PLYWOOD. WALL TO RECEIVE 5/8" GYP. BD. GAP. NEW NON -RATED 3 5/8" METAL 5TUD WALL CONSTRUCTION. ON TOILET ROOM 51DE OF 5TUD5 ONE (1) LAYER OF 1/2" GEMENT BOARD _ - TO 4'-q" A.F.F. AND ONE (1) LAYER OF I/2' 6REEN130AR-0 FROM 4'-q" A.F.F. TO 3" ABOVE ADJAGENT CEILING. ON GORRIDOR/JANITOR'S CLOSET SIDE OF STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" ABOVE ADJACENT CEILING. NEW 5OUND ATTENUATED NON-RATED'WALL NEW NON -RATED 3 5/a" METAL 5TUD t. CONSTRUCTION. 3 5/8 METAL STUD5 W/ %b" i WALL 60N6TRUGTION; ONE "(1) LAYER OF GYP. N H , 6 . BD. 0 EAG I F 5 DE 0 STUDS T 0 BOTT M �., •, ' 2 N r, '. I/ CEMENT BD. TO 4 -q A.F.F, AND ONE OF METAL DECK ABOVE. FILL ALL 57UD . = I LAYER OF I R O O /2 G EENBOARD FROM i GAVITIES FULL HEIGHT WITH FIBERGLASS - AF.F.T031 ABOVE D A GENT aL :5 5OUND REDUCING BATT (FL INSULATION (FLAME ME CEILING ON BOTH 51f7E5 OF STUDS., SPREAD 10, SMOKE DEVELOPED 10). BLANKET GEILING WITH SAME BATT INSULATION 4" TO NEW 2 HOUR -RATED 3 5/8" METAL STUD WALL ? i EAG H SIDE OF WALL. ( CON5TRIX TION. ON BOTH SIDES OF 5TUD5 I TWO (2) LAYERS OF 5/8' TYPE 'X" GYP. BD. A NEW NON -RATED FURRED -OUT WALL TO UNDERSIDE i1.1 O OF DECK ABOVE. G.G. TO OCONSTRUCTION. 15/5" METAL STUDS. ON VERIFY ADJAGENT WALL CONSTRUCTION f �----� EXPOSED SIDE OF 5TUD5 ONE (1) LAYER TYPE AND RATING. 29110 Inkster Road. OF 5/6' GYP. BD, TO ADJACENT GEILING. NEW NON -RATED 6' METAL STUD PLUMBING WALL CONSTRUCTION. ONE (I) LAYER OF I/2" OV f GEMENT BD. TO 4'-q" A.F.F. AND ONE (1) I----- LAYER OF 1/2" 6REENWAR-0 FROM 4'-q" A.F.F. TO 3" ABOVE ADJACENT CEILING ON EXPOSED SIDES OF 5TUD5. NEW NON -RATED 6' METAL STUD PLUMBING WALL GON5TRUGTION. ON EXP05EP 51DE5 OF STUDS ONE (1) LAYER OF 5/8" GYP. BD. TO 3" ABOVE ADJACENT CEILING. SCALE: 1/4" = I'-0" ARGHITEGT RAL 6ENERAL Nc T . A. TENANT CONTRACTOR SHALL FIELD VERIFY ALL EXI5TIN6 CONDITIONS PRIOR TO START OF CONSTRUCTION / FABRICATION. B. DIMENSIONS ARE TO FACE OF GYP. BD. WALLS, UNLE550THERWI5E NOTED. REFER TO DECOR PLAN, ELEVATIONS AND DETAILS FOR FINISHES. G. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMLN510% ONLY. SUBMIT TO ARGHITEGT ANY 1)156REPANGIE5 FOR GLARIFIGATION. D. G.G. TO INSTALL AND PROVIDE 2AIOBG FIRE EXTINGUISHERS. REFER TO TH15 SHEET FOR LOCATION5. E. ALL WORK SHALL BE IN COMPLIANCE W/ THE ADOPTED LOCAL CODES, AIA A-210 6ONDITION5 OF THE CONTRACT FOR GON5TPJY TION, RECOGNIZED INDUSTRY 5TANDARD5 IN THE AREA, ALL MANUFACTURERS RECOMMENDATIONS AND ALL OTHER APPLICABLE CODES. F. PROVIDE ACCESSIBILITY FOR THE PHY516ALLY HANDICAPPED. -'&,ALL 4.1OD,-EXGEPT-TRIM,-TO BE FIRE •RETARD,ANT,T-RFAT'FP. 09WACT W/ CONCRETE OR GON6RETE BL06K TO BE PRESSURE TREATED. t, 6L. TO COORDINATE AND PROVIDE FIRE RETARDANT PLYWOOD AND OR BLOGKIN6 IN k0_1 L5 FOR ALL WALL ATTACHED EQUIPMENT, WALL ATTACHED FURNl5I1ff466, SIGNAGE, LI&WiN6, FTG. ARCHITECTURAL. •GENERAL NOTES GONTINUED: J. G.G. TO INSURE ALL INTERIOR WALL BLOGKING 15 IN5TALLED PRIOR TO APPLYING WALL FINISHES. K. STOREFRONT GLAZING TO BE SAFETY GLASS. ALL ED6E5 MUST BE GROUND AND POLISHED. L. G.G. TO COORDINATE AND PROVIDE AGGE55 PANELS IN GEILINGS FOR EXISTING AND NEW VALVES, WNTROL5 AND EQUIPMENT. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. M. ALL FLOOR ELECTRICAL BOXE5 TO BE INSTALLED FLUSH W/ NEW FLOORING AT GA5HWRAP AND AT FIXTURES W/ POWER 15 SHOWN ON ELECTRICAL SHEETS. N. IT SHALL BE THE 50LE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO TEST MOISTURE CONTENT OF 5013 FLOOR PRIOR TO INSTALLATION OF ALL FIN15H FLOORING NIATERIAL5 AND TO MAINTAIN PROPER TEMPERATURE AND HUMIDITY LEVELS PER MANUFA6TURER'5 5PEGIFIGATION5. D. G.G. SHALL PATCH, REPAIR AND INSTALL NEW FIREPROOFING TO ALL EXI5TIN65 / NEW / ,FROP05ED ,TEEL TO MAINTAIN FHRE-RRATIN6. • •F.G. TO PROVIDE ALLOWANCE IN 1319. REFER TO COVER SHEET FOR MORE INFORMATION. P. G.G. TO VERIFY ALL COLUMN LOGATION5 AND CONDITIONS. NOTIFY ARGHITEGT IF THERE ARE ANY DIFFERENCES. Q. ALL GYP. BD. SURFACES SHALL BE A LEVEL 5 FIN15H PRIOR TO PAINTING. Suite 200 s Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Copyright `C 2008 j KEN NISCH, AIA All rights reserved Certification:'' 11 1.1 i' Consultants - RETAIL DESIGN CONSULTANT 71 JGA Inc 29110 Inkster Rood Suite 200, Southfield, Ml 48034 USA w 248 355 0890 248 355 0895 fax AN .; /' ,._« �, www.jgo.com JGA Pr j #: 1-209-057 ,. DRAWINGS ISSUED FOR: ❑ programming ! i III schematic des. 02.0q.0q i l' i El design dev. 0 bidding IN permits 03:16'.041 O construction 10 landlord prelim. 02.041.09 { 11landlord final 02.27.Oq REVISIONS: �i Prj. no. 8-041 012 ;1 Drawn RG, TW Checked ALS iI Approved KN ,ii Do not scale this print. Use figured dimensions only. 1 9 Drawing title: ENLARGED.' ARCWITECTURAL FLOOR PLAN Sheet no. A coo ,i IN g SCALE: 6' = 1'-0" AL 5TUD5 REFER TO 5HEET5 I, A-12, A-1.3, A-1.4, AND A-1.5 : MORE INFORMATION. 5N 5TUD KNOGKOUT5 (TYP). 'GYP, BD. REFER TO 5HEET5 A-1.2, A-1.3, A-1.4, AND A-1.5 : MORE INFORMATION. 14" x 3/8" PREFIN15HED MDF BASE, >VIDED BY OHNER, GUT, MITERED, ALLED, AND 'aHED-UP/GAULK.ED AT FLOOR AND OF BA5E AT HALL BY TENANT5 ERAL CONTRACTOR. REFER TO 5HEET AND 5HEET5 A-3.1, A-3 2, A-3.3 FOR LOGATION5. GK AT FLOOR AND BOTTOM 5TRUGTURE ANCHORED AT A OF 2'-0' O.G. 5H FLOOR. REFER TO 5HEET 5 FOR MORE INFORMATION. �4XIB1 E SEALANT. GONGRETE FL OOR 5L AB A55EMBLY. CENTER -LINE OF DOOR JAMB. GO'NGRETE COMPOSITE TILE ON MA5TIG BED ON MEMBRANE. 5L OPE5 TO NOT EXCEED 1:20 PER GBG 1003.3.4. V.G.T. FLOOR ON MA5TI6 BED. TAPER MIN. 36" FROM EDGE OF TRAN5ITION WITH CONCRETE TOPPING. 56HLUTER TRAN5ITION STRIP, AE -100 10' HIGH. EXI5TING GONGRETE FLOOR 5LAB. P. ' C. P. TIL o o e FLOORITT SCALE: FULL ft -con -tile P -I GEILING MP -2 HALLS - PAINTED �HALL5 - HAIN'-SGOT {^IB -2 13UL L N05E 0 WAIN5GOT �I BA5E PT -I FLOOR - NOTE #1 JAN. GLO5ET FIN15HE5 WT -1 GEILING P-2 HALL5 VHB-I BASF VCT -6' FLOOR - NOTE #1 ELECT. ROOM FIN15HE5 N/A GEILING VGT-I FLOOR VYJB I BA5E VGT-I FLOOR BA5E VGT-I FLOOR (VWB-I T3A5E VCT FLOOR Ir_�irr_R-LINE OF DOOR JAMB. jAMBAARIM BEYOND. 5URFACE TILE ON THIN5ET 4 TOILET ROOM. .5 TO NOT EXCEED 1:20 BC 1003.3.4 TYP. EAGH )F OPENING. LE THRESHOLD ON THIN5ET ON MA5TIG BED- TAPER F 36" FROM E1?6E OF iITION WITH CONCRETE Na. TYPICAL LMARBLE THREEMVIOLD TRANSITION SCALE: FULL f t-mrbl-thr5h ER -LINE OF DOOR JAMB. TING CONCRETE FLOOR IN EXIT RIDOR. \L ANGLE TRAN51TION STRIP. DE TO NOT EXCEED 1:20 PER GBG .3.4. FLOOR ON MASTIC BED. :R MIN. 36" FROM EDGE OF 451TION HITH GONCRETE DING. TING GONGRETE FLOOR 5LAB. V.C.T. TO EXI"""INGCONURETE FLOORING 56ALE: FULL ft-vct-exst PEGOR/ FLOOR GOVERIN6 KEY NOTES: 3�� t BA5E "SGT -I FLOOR G.G. TO ADD 4" HI6H WATERPROOF MEMBRANE IN WATER COOLER ALCOVE. REFER TO NOTE 01 ON THI5 SHEET ADMIN. OFF16E FIN15HE5 AGT-I GEILING P-2 HALLS (CON -1) IN 5ALE5 AREA. VHB-I BASE VGT-I FLOOR HAIN5GOT IN B.O.H. CORRIDOR, 5EE DETAILS TO JANITORS SINK. B.O.H. CORRIDOR FIN15HE5 ALL CONGEALED SPRINKLER HEAD GOVER5 IN GEILINC75 ACT -I GEILING EDD IALLS OPEN GE I L I N6 FINISH NOTE: :?�t3 VCT -I FLOOR DASHED LINE INDIGATE5 APPROXIMATE LOCATION OF 6.G. 5HALL PAINT ALL EXPO5ED AND VISIBLE ITEMS IN OPEN GEILING AREA. ITEM5 5HALL INCLUDE BUT NOT BE H4M WALL GRAPHIC. FINAL LOCATION TO BE DETERMINED BY ON-51TE HdM REPRESENTATIVE. REFER LOi� )"f�tI5�4E5 TO TH15 SHEET AND H4M GRAPHIG5 CATALOG FOR (ACT -1 GEILiA16 MORE INFORMATION. P-2 HALL5 HB -I BA5E B VGT-I FLOOR - NOTE 01 FLOOR TRANSITION ADA NOTE: BA5E VGT-I FLOOR (VWB-I T3A5E VCT FLOOR Ir_�irr_R-LINE OF DOOR JAMB. jAMBAARIM BEYOND. 5URFACE TILE ON THIN5ET 4 TOILET ROOM. .5 TO NOT EXCEED 1:20 BC 1003.3.4 TYP. EAGH )F OPENING. LE THRESHOLD ON THIN5ET ON MA5TIG BED- TAPER F 36" FROM E1?6E OF iITION WITH CONCRETE Na. TYPICAL LMARBLE THREEMVIOLD TRANSITION SCALE: FULL f t-mrbl-thr5h ER -LINE OF DOOR JAMB. TING CONCRETE FLOOR IN EXIT RIDOR. \L ANGLE TRAN51TION STRIP. DE TO NOT EXCEED 1:20 PER GBG .3.4. FLOOR ON MASTIC BED. :R MIN. 36" FROM EDGE OF 451TION HITH GONCRETE DING. TING GONGRETE FLOOR 5LAB. V.C.T. TO EXI"""INGCONURETE FLOORING 56ALE: FULL ft-vct-exst PEGOR/ FLOOR GOVERIN6 KEY NOTES: PEGOR PLAN LE END: 1 G.G. TO ADD 4" HI6H WATERPROOF MEMBRANE IN WATER COOLER ALCOVE. REFER TO NOTE 01 ON THI5 SHEET 2'-O'x2'-O' ( OWRETE TILE 'FOR (CON -1) IN 5ALE5 AREA. MORE INFORMATION. G.G. TO ADD 4'-0" HIGH HAIN560T ON HAL1-5 ADJACENT HAIN5GOT IN B.O.H. CORRIDOR, 5EE DETAILS TO JANITORS SINK. ON 5HEET A-5.3 FOR MORE INFO. ALL CONGEALED SPRINKLER HEAD GOVER5 IN GEILINC75 HITH FIN15H OTHER THAN HHITE 5HALL OM OPEN GE I L I N6 FINISH NOTE: ORDERED TO MATCH ADJAGENT GEILINB6 PAINT DASHED LINE INDIGATE5 APPROXIMATE LOCATION OF 6.G. 5HALL PAINT ALL EXPO5ED AND VISIBLE ITEMS IN OPEN GEILING AREA. ITEM5 5HALL INCLUDE BUT NOT BE H4M WALL GRAPHIC. FINAL LOCATION TO BE DETERMINED BY ON-51TE HdM REPRESENTATIVE. REFER LIMITED TO: SPRINKLER LINE5, UN15TRUT DECK, STRUCTURE, TO TH15 SHEET AND H4M GRAPHIG5 CATALOG FOR ETC. ALL EXP05ED-QUrTHORK 5HALL BE KEPT GLEAN OF MORE INFORMATION. OVER5PRAY. 6.G. 5HALL PROTECT ALL OTHER ITEM5 THAT ARE NOT TO BE PAINTED: I.E. LI6HT5, TRACK, ETC. HALL BAS TOTAL AMOUNT5: FLOOR TRANSITION ADA NOTE: TOTAL LINEAR LENGTH OF WALL BA5E IN 5ALE5 WB -I FLOOR AND FITTING ROOM AREA5 = 1OW-6". ALL TRAN5ITION5 OF FLOORING MATERIALS TO MEET ADA 6.G. TO VERIFY AMOUNT IN FIELD. REGUIREMENT5. TOTAL LINEAR LENGTH OF WALL BA5E IN BACK yy�_I OF HOU5E AREA5 AND OFFICES = 52q' -O". 6.6. TO VERIFY AMOUNT IN FIELD. TOTAL LINEAR LENGTH OF WALL BA5E IN TOILET ROOM AREA5 = 17l' -q". G.(. TO VERIFY AMOUNT PTHB-I IN FIELD. 40T TO EXCEED 1:20 PER 3.3.4 TYP. EACH 510E. )R STONE. 6ARIFY 5URFAGE :CURE BOND. GOWARETE F -L" ft-wtr-bar a — M A LL I ECSR/FLOOR COVERM PLAN .011 NOR I DE60R GENERAL NOTE5. A. REFER TO REFLECTED GEILING PLAN FOR GEILING FINISHES. B. ELECTRICAL REGEPTAGLE5, 5HITGH PLATES AND ELECTRICAL COVER PLATES TO BE WHITE OR 5.5. G. CEILING REGEPTAGLE5 AND COVER PLATES TO BE WHITE OR 5.5. (REFER TO ELECTRICAL PLAN FOR LOCATIONS AND TO REFLECTED CEILING PLAN FOR CEILING FIN15H INFO). D. ALL GEILIN65 WITHOUT A FIN15H DE5I6NATION (P -X) TO BE PAINTED 7-111 . E. ALL HALLS WITHOUT A FIN15H DESIGNATION (P -X) TO BE PAINTED 'P-2". F. REFER TO SHEET A-02 FOR AGGENT COLOR INFORMATION. G. ALL LIGHT TROUGH5 IN FLOATING GEILING TO BE PAINTED BLACK "P-60 . 'H. ALL GEILING DIFFU5ER5 TO BE PAINTED TO MATCH ADJACENT GEILING GOLOR UNLE55 GEILING 15 PAINTED "P-1". IF GEILING 15 PAINTED "P-1" THEN GEILING DIFFU5ER5 ARE NOT PAINTED. I. FOR ALL FLOATING GEILINC75 NOT PAINTED "P-1", G.G. TO PAINT DIFFU5ER5, 5PREAKER5, DUCT5, ETC. TO MATCH. J. G.C. TO PROVIDE TWENTY-FIVE (25) WHITE CORNER 6UARD5 FOR SAI_E5 FLOOR WALL5 AND 5TAINLE55 STEEL CORNER 6UARD5 AS 5HOHN FOR BACK OF HOUSE HAL L5. REFER TO H4 M ON-51TE REP. FINAL PLACEMENT DIRECTION OF CORNER GUARD5. FLOORING NOTE #I: HATERPROOF MEMBRANE 5HALL BE IN5TALLED IN THI5 AREA HITH A MINIMUM OF 5" WRAP ON ALL ADJACENT HALL5. G.G. TO IN5TAI_L MEMBRANE PRIOR TO IN5TALLATION OF FLOOR FIN15HE5. 5ALE5 FLOOR GRAPH IG NOTE: TENANTS GENERAL CONTRACTOR TO COORDINATE WITH PAINTING CONTRACTOR AND H4M PROJECT MANAGER THE REGEIVIN67 OF 5TENGIL5 FOR 6RAPHIG PAINTING A5 LOCATED ON DECOR PLAN. THE THREE TO FOUR 5TEP PROCE55 INGLUDE5 THE BA5E PAINTING OF THE WALL AREA, THE PROPER INSTALLATION OF THE OHNER PROVIDED 5TEN6IL, THE 5EGOND AND THIRD COLOR A5 NOTED (PO551BLY FOURTH) ON ELEVATION IN5TRUGTION5 AND THE GAREFUL REMOVAL OF OHNER PROVIDED 5TENGIL. CONFIRM DI5PO51TION OF THE 5TEN6IL AFTER U5E. REFER TO "H8 M° PROVIDED 6RAPH1G5 GATALO6 5PRIN65 2006/2001. 5ALE5 FLOOR 1NALL BASE NOTE: AT ALL WARDROBE FIXTURE5 WALL E3A5E END5 AT PROJECTION OF HARDROBE. HALL BASE TO BE APPLIED AFTER HARDROBE FIXTURE IN5TALLATION. REFER TO 5HEET5 F -I.1, F-1-2, F-1.3, F-1.4, AND F-1.5 FOR LOGAT10N5 OF WARDROBE FIXTURES. I FITTING ROOM P -i GEILING P"2 HALL5 WB -1 BASE GON-i FLOOR- 4— LOOR 'V > Consultants: RETAIL DESIGN CONSULTANT rna� 9 IA• _-- 1-209-057 DRAWINGS ISSUED FOR: 0 programming 19 schematic des. 02.0q.Oq EJ design dev. C7 bidding 0 permits 03.16.Oq ❑ construction 0landlord prelim. 02.0q.Oq ® landlord final 02.27.Oq REVISIONS: Prj. no. 8-209-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: DECOR AND FLOOR COVERING PLAN Sheet no. REFLECTED CEILING PLAN LEGEND A (D b" REGE55ED COMPACT FLUORESCENT OPEN DOWNLIGHT W/ EMERGENCY BATTERY PACK. REFEi�"T0 EL G RIGAL SIfEETS' OR MORE INFO. E 02.0q,0q GLG. HGT. 5PEAKER. REFER TO ELECTRICAL 5HEET5 FOR MOR�E,IRFORMATION. TYPE 2 22(73` PTD. GEILING MOUNTED fIXTURE. 6.G. TO 511PPLY 1/2" FRT. PLYWOOD BLOGKIN65 IN CEILING. REFER TO'�HEET5 F-1.1, A-22, A-23, AND A-2.4 FOO PARE IWORMATIO*L 1 11 G Q b„ REGE55ED COMPACT FLUORESCENT OPEN POHNL16HT W/ EMERGENGY BATTERY PACK NIGHT -LIGHT. REFER TO ELECTRICAL 5HEET5. T RE�rl=f�'T'G'5E(1 AND'I3ETAiLS. REGE55ED 3-CIR6UIT LIGHT TRACK - WHITE. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. 2336 CEILM I' 1_NTED FIXTURE, 6.G. TO 5I1 -MY I/2' FJZT. PLYWOOD BLOCKING IN CEILIN5. REFER TO SHEETS F IJ, A-22, A-23, AND A-2 4 F{ t;RE INFORMATION D Q b" REGE55ED METAL HALIDE DOWNLIGHT W/ SEMI -DIFFUSE ALUMINUM REFLECTOR. REFER TO EL EGTRIGAL 5HEET5 FOR MORE INFO. TI ® METAL HALIDE REGE55ED TRACK HEAD. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. E 0 4 I/2' REGE55ED METAL HALIDE DOWNLI6HT W/ 5EMI-DIFFU5E ALUMINUM 5UNR15E OPTIC REFLECTOR. REFER TO ELECTRICAL 5HEET5. EXI REDUCING BATT IN50LATION. REFER TO 5EGTION5 L.E.D. EDGE -LIT EXIT 516N W/ EMERGENCY BATTERY PACK. REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. 2331 GLG_ NGT. GElLtNS'MOUPITED FIXTURE. 6L. TO PLY I/2' FR.T. PLM001s _BLC`G URE.ING5 l6L. T t S REFER F3 � OOP &IDG22# }4-,23, AND IW5. FOR MORE WORMATION. TYPE 6 �® REGE55ED DOWNLIGHT. REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. EX2 L.E.D. EXIT 5I6N W/ EMERGENCY BATTERY PACK. REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. AIR DIFFUSEP, EEE MEC#f WAL x'15 fOR MORE ITORMATtOR G 4'-0' GHAIN MOUNTED EXP05ED 51NGLE BULB FLUORESCENT. REFER TO ELECTRICAL 5HEET5 FOR -tWE *FORMATION. EMI EMERGENGY LIGHT. REFER TO ELECTRI G� 5HEET5 FOR MORE INFORMATION. 'r'L'1r' -AIR BILE. FOR MORE INFOR MA" IM, H 2'-O'x4'-O" RE6E55ED FLUORESCENT. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. EM2 AAA6 EMERGENCY LIGHT. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. CEILINt; ACCE5517ANEL PI lOW COMPAGT FLUORE5CENT DECORATIVE PENDANT PROVIDED BY OWNER. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. , AIR DIFFU5ER. REFER TO MECHANICAL 5HEET5 FOR MORE INFORMATION. -- SPEAKER REFER: ELELTRIGAL 5HEET5 K7Iz MORE INFOT�ATIC7�+1. 2200 GEILING MOUNTED FIXTURE. G.G. TO SUPPLY 1/2" F.R.T. PLYWOOD BLOCKING IN GEILING. REFER TO 5HEET5 F-I.I, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. OL O b' REGE55ED DOWNLIGHT. REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. REFLECTED GE I L I NC5 KEY NOTES: LOCATION OF DIFFUSERS. REFER TO MECHANICAL 5HEET5. [2] "PrWL VEAMR` it G r l 1` :G. ' O )fT 5' Ak E Z"Cff�UaINCS, HAV KS Ai` 7' ( H= 1'ii ?AiLis+TTt7N'1'R 'lE3( ELEGTRIGAL CONTRACTOR. REFER TO 5HEET A-0.1, A5 ],,ELL A5 FIRE PROTECTION 5HEET5 (BY OTHERS), FOR 5PRINKLER INFORMATION IN ALL AREA5. LAYOUT OF HEAD'S 5HALL BE WORKED INTO THE GRID OF LI6HT5 E5TABL15HED. HEADS WILL NOT 13E APPROVED IF RANDOM PLACEMENT OCCURS. [4], 6.6. TO PROVIDE FLU5H CONCEALED (INTEXFORM5 PHONE #: 40b-b4b-5(9b1) 6LA55FIBES' ACCESS PANEL IN GYP. BD. CEIL N6 FOR 5TOREFRONT 516N (COORDINATE LOCATION WITH 5IGN GONTRAGTOR). REFER TO 5EGTION *14 ON SHEET A-2.4. 5 G.G. TO PROVIDE AND IN5TALL FLUSH CONGEAL ED (INTEXFORM5 PHONE #: 408 -&4b -5b(97) 6LA55FIBF-R AGGE55 PANEL5 IN 6YP. BD. CEILING FOR AGGE55 TO DUCT WORK, LIGHTING, EQUIPMENT, CONTROL PADS, ET, COORDINATE LOCATION WITH TENANTS FIELD REP. REFER TO 5EGTION #4 ON 5HEET A-2.4. LIGHT FIXTURE5 LOCATED IN FITTING ROOM WALL5 FOR ILLUMINATED MIRROR5, NOT IN CEILIN6., ELECTRICAL CONTRACTOR TD COORDINATE J -BOX LOCATION. aLINE OF MALL BULKHEAD. LEA5E LINE. ILLUMINATED TENANT STOREFRONT 5I6N. REFER TO 5HEET5 A-4.1, AND A-4.2 FOR MORE INFORMATION. 11-01 CEILING CONTROL JOINT. EEDGE OF 'FLOATING GEILING.' 12 EDGE OF 5TOREFRONT 5OFFIT. FLOOR TO GEILING FIXTURE. 6.C. TO PROVIDE 1/2" PLYWOOD BLOCKING . IN GEILING. REFER TO TH155HFET AND 5HEET5 13 F-I.I, F-1.2, F-13, F-1.4, F-1.5, A-2.2, A-23, A-2.4 AND A-2.5 FOR MORE INFORMATION. IN FLOAT IN6 CEILING AREA5 ]BLOC KIN5 TO COVER SPACE FROM EDGE OF FLOATING GEILIN6/L16HT TROU(S)H/YJALL TO EDGE OF FLOATING GEILING/! 164T TROUGH/WALL. REFER TO NOTE 015 ON THI5 5HEET FOR ALL OTHER AREA5. 1 4 HATCHED AREA INDIGATE5 AIR DIFFU5ER. REFER TO LEGEND ON THI5 5HEET AND MEGHANIGAL 5HEET5 FOR MORE INFORMATION. 1� DA5HED AREA INDIGATE5 IN-GEILING 1/2" F.R.T. PLYWOOD BLOCKING FOR FLOOR TO 6 -SLING FIXTURE BELOW. I(o REFER TO ELECTRICAL PRAHINC75 FOR MORE INFORMATION ON HATCHED L16HT5. H DA5HED AREA INDICATE5 IN-GEILING 1/2" F.R.T. PLYWOOD BLOCKING FOR FRAHE5 FIXTURE BEL OkL REFER TO 5HEET A-23 FOR MORE INFORMATION. REFLECTED GEILING PLAN GENERAL N®TE5: A. G.G. TO PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING 5EGURED TO 5t6PENDED METAL FRAMING BEHIND GYP, BD. FOR CEILING MOUNTED FIXTURING. 13. CG.C, TO PROVIDE AND IN5TALL FLU5H CONGEALED INTEX FORMS (408-b4b-5bb1) AGCE55 PANEL5 IN GYP. BD. GEILING, GENERAL GONTRAGTOR TO PROVIDE EIGHT (b) PANELS IN 24x24 51ZE AND ARE TO BE LOCATED AND COORDINATED WITH H4 PROJECT MANAGER. FINAL LOGATION5 TO BE DETERMINED. G. G.G. TO GLEAN 4 RE -LAMP ALL IN5TALLED LIGHTING FIXTURE5 PRIOR TO TURN OVER A5 REQUIRED. D. LIGHTING FIXTURE LEGEND 5HOWN 15 TO DE516NATE FIXTURE TYPE5 AND ARE NOT TO BE GON5IDERED 5PECIFIGATION5. 5EE ELECTRICAL PRAHINC25 FOR LIGHT FIXTURE 5PEGIFIGATION5. E. REFER TO ME( HANIGAL 5HEET5 FOR FIRE PROTECTION DIRECTION. ALL FIRE PROTECTION SPRINKLER HEAD5 ARE TO BE PLACED A5 TO NOT INTERFERE WITH LIGHTING, HVA(, AND 5TORE FIXTURING GOMPONENT5. F. ( EILING GRID IN BACK OF HOUSE SUPPORT OFFI6E5 ARE TO BE HUNG WITH #12 HANGER WIRE5 (4b'06) WITH ADDITIONAL WIRE5 AT ALL FOUR CORNERS OF ALL LIGHT FIXTURE5; DIFFU5ER5, ETC. G. ALL DIRECTIONAL EXIT 516N5 ARE INTERNALLY ILLUMINATED. H. ALL 505PENDED COMPONENT5 ARE TO BE 5U5PENDED FROM TOP CHORD OF BAR J015T5. DO NOT ATTACH 5U5PEN510N ATTACHMENT5 FROM METAL ROOF DECKING (IN CONCRETE DE( KIN6 U5ED APPROVED CONCRETE FA5TENER5). I. -G.G. SHALL - PRICE A5 ALTERNATE THE PAINTING OF ALL .fXPQ5ED 5TRUGTURAL, DUCTWORK, PIPING ETC. IN ROOM5 5PEGIFIED A5 'OPEN TO CON5TRUGTION ABOVE'. PRICE DIRECTION A5 OPTION. J. 5U5PENDED ACOUSTICAL CEILING 5Y5TEM 15 TO BE IN COMPLIANCE WITH IBC 5EGTION5 b(A3.1 AND 2506.2.1 AND A5TM G b35 AND A5TM G b3b. K_ ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNEGTION5 TO MIL LkIORK/FIXTURE5/GA5HWRAP5 IN FIELD. L.. COORDINATE LIGHTING FIXTURE LOGATION5 AND DIFFU5ER LOGATION5 WITH OTHER MECHANICAL GOMPONENT5 WITH LIGHTING BEING THE DECIDING COMPONENT. M_ 5PEAKER5 PROVIDED 4 IN5TALLED BY OTHERS. GENERAL CONTRACTOR TO PROVIDE CONDUIT, WIRE5 AND SPEAKER CAN5 A5 54,!Ok�W ON ORAWINGS. OI R'a VENDOR TO IN5TALL FINAL HOOK IJP OF 5PEAKER5 AND EQUIPMENT. TENANT5 ARE PROHIBITEP TROM ALLOWING MU51G OR OTHER 5OUND5 TO EMANATE FROM THEIR 5PAGE5 INTO MALL COMMON AREA OR TO ADJACENT TENANT 5PACE5. TENANT5 WHO GENERATE MODERATE OR HIGH SOUND LEVEL5 GREATER THAN 40 DE61DEL5 OR A5 OTHERWISE REQUIRED BY L.L. SHALL INSULATE THEIR DEM151NG WALL5 AND GEILING5 A6AIN5T SOUND TRAN5MI5510N. THE LOCATION AND 5PEGIFIGATION OF 5UGH AC OU5TIGAL PREVENTIVE METHODS MUST BE THOROUGHLY DETAILED ON TENANTS PLANS AND 15 SUBJECT TO LANDLOR05 APPROVAL. TENANTS 5HALL NOT LOCATE 5PEAKER5 OR ANY N015E 6ENERATING DEVICES WITHIN 12'-0" OF. ANY _STDI EFRONT, A0 ,5RHA .ANY .5PEAKER5 OR DEVICES BE DIRECTED TOWARD THE STOREFRONT OR 5TORE.ENTRY. TENANT5 FURTHERMORE 5HALL NOT PLACE 5PEAKER5 (INCLUDING 9)BWOOFER5) OR ANY N015E 6ENERATIN6 DEVIGE5 INTO OR WITHIN 12'-0" OF ANY DEM151NG WALL. W40%`1 , REELECTED GE I L I NCS PLAN GENERAL . NOTES CONT,. N. G.G. TO MAXIMIZE GEILING HEIGHT IN ALL.5TOREFRONT AREAS THAT OCCUR BELOW SECOND LEVEL. G.G. TO MAINTAIN FLUSH CONDITION IN THESE GEILING AREA5. 0. BOTTOM OF ALL TRACK IN GEILING TYPE 1" AREA5 ARE TO BE MOUNTED II' -IO' AFF. P. BOTTOM OF ALL DECORATIVE PENDANT LIGHT FIXTURE5 IN GEILING TYPE 'I" AREA5 ARE TO BE MOUNTED II' -2' A.F.F. Q. TENANT'S CEILING HEIGHT MAY. BE LIMITED BY 5TRUGTURAL OR MEGHANIGAL 0135TRUGT'ION5 - G.G. TO f IELD VERIFY ALL CLEAR HEIGHTS. R. AGGE55 PANELS IN GEILING MU5T BE LOCATED TO PROVIDE A66E55 TO LANDLOR05 MEGHANIGAL EQUIPMENT PER LOCAL GENERAL GROWTH AUTHORITY. 5. 5PRINKL ER HEA05 AT 6YP5UM BOARD 6EILING5 MU5T BE FULLY RE6E55ED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT 5URFACE. CENTER SPRINKLER HEADS IN GEILING5 TILES WHERE APPLICABLE. T. ALL NEW LOW VOLTAGE WIRING MLST BE IN CONDUIT. U. EXIT LIGHTING MU5T NOT 13E V151BLE FROM THE MALL VIEW, REFLECTED GEILING TYPES CLG. 1 TECA11 EXP05ED METAL DEGKIN6 CONSTRUCTION ABOVE. E 02.0q,0q GLG. HGT. WD" GYP. BD. ON 3/4" F.R.T. PLYWOOD 5EGURED TYPE 2 TO 505PENDED METAL FRAMING. REFER TO PTD. 5EGTIONS 4 DETAIL5. LG. NGT. 3 !PTED. 5/b" GYP. BD. GEILING ON 5U5PEN51ON 5Y5TEM BY G.G. ,E RE�rl=f�'T'G'5E(1 AND'I3ETAiLS. I; 1--209-057 I i I'' 1 I<<. yl. I GLG. HGI. TYPE q 24"x4b'x5/b" AGOU5TIGAL GEILING TILE5 5J5PENDED IN GRID, IIANUF. CLG. 1C,T, 4"x4t,'x5/b" AC,016TICAL CEILING TILE5.54PENDE12 TYPE 5 IN GRID WITH 5OUND ATTENUATED FIBERGLASS SOUND REDUCING BATT IN50LATION. REFER TO 5EGTION5 MANUF. AND DETAIL5. GLG_ NGT. 5/5" GYP. BD. ON 1/2" F.R.T. PLYWOOD 5EGURED TYPE 6 TO 5U5PENDED METAL FRAMING. REFER TO PTD- 5EGTION5 4 DETAIL5. i q' -D" AFF EGRE55 CORRIDOR TYPE 3 PTD. , I ; ELEGTRIGAL EXPOSED TYPE I EXPOSED q'-0' AFF TYPE 4 NANUF. IGS a 4-0' :AFF TYPE 5 ANUIF_ I� -Op aFF _f:� YPE 4 12'-0" AFF TYPE 4 MANUF. 10'-2' AFF TYPE 3 PTD_ A 25 pli MENSI S _ __r - -- ROOM16 TOILE __ 1 13 Ex R QO 1(0 1(0 EXl O O O O O Q O O O G T 0OMENS 16 ' 1& ROOM O O O O OTOILEO 7Ff 9 -.9 - - .9-- c- ai 1®66 �( o -_ 1 1 I3 �1(o] 0 O 3 O O O O .O O A -z4 O O13 FLOOR 10-2AFF -2" AF I 16 0U TYPE 3 10, TYPE �2 15 A 0 16 EXE PTD. -. -Q 0 o Q o 0 0 a x2:::T 10,_n � ID Iro ' O I O O5MI-K 20OhO 1 O © F o O O IfI1 ADMI ni� OFFICE 1�13 ° o M� b ; ,. Ext - � - o o o. a U 1 of_-------- --_-- - - - - - -_ =---DECO ROOM 5AEFLOOR F I& o O Q A ISALEo FLOOR A-251 UA - I - _ I A-5? 5 t11 zo o0 Q O o o Q ------------ - - - -- 5-j AFF IIIIIIIIi O 1 ' O 1 l-J1CO - 0 r� �Q I _O ># _O TYPE 25 A PTDCo o LEi ° 11 I n <o � 1 1 5Ao o:o o 1c�o o 0 A -2o yrI0_2 AF X1 I TYPE 3 � O O kA-2A)- PTD. O o o i � o o o o 0 O O 10, fl ROS ; A-2.4 klj�� � J_ ° 4 o o � o � o ;o o 0 1 o I o _- - __ __ _ __ - _ - _ _- - A-25 o 0 o ----- _u O O o o o o FI& o 0 0 0 0 o o 1 2 3 a I OU O A-zs U , O - -I 5 A-2.4 J. -➢ _ ® _ -l- ' (���1 - � JII ij 1I( � IIIIlIII � (-�(0 - �I l r _-- -- -L L- _ - - - � � �o o o o 'FITTING 0 10 ROOM -5 Q p °O 0 0 0 TYPE 3 A-2_ PTD. A 42A) I , A 52 8 6" AF F O TYPE 30 U-2-470 r O O O `l 10 -2a AFF I L- A-?51� q-2 718 A - ?S 9 PTD. TYPE 3 TYPE 6ID ®®® ( PTD. PTD. o O x1 i A -2A o O O o 0 0 0 I O 10 - , L ° o 310, 11 I_A-25 oilQO O O O O O 5ALE5 FLOOR 10'-2" AFF i OO O 16,11 O O O OID I TYPE 3 1 P 5AtE5 fL0o ! 0 o o o A -?5 -z� A5 A A -23 O O 10 O o O o 74 .� -' A-25IA-25 A -2d A -2q a I 4 o q O TO EXA-?4 O �-2.4 0 0 L0 0 o A-2. o -- 1E FFAFF i2 -0"AFFell PE 2 A-2.. l2'-0° AFF 2'-0" AFF 12-0" AFF 12'-0" A2TYPE 2 -2 -z -2 QA4 A A -z5 PTD. TYPE 2 TYPE 2 A-2.4 PTD %\ . PTD. PTD. PTD. PTD. W PTD 1 2 j WIN < MALL C0%NC0"R`%E 4 "t"ILING PLAN SCALE. W' a 1'-0" NOTE: - REFER TO 5HEET5 A-2.2 AND A-23 NORTP FOR GEILING AND LIGHTING DIMEl+5016 AND MORE INFORMATION. .1i Consultants: 1 RETAIL DESIGN CONSULTANT i ii JGA iNc 02.0q,0q 29110 Inkster Rood Suite 200 Southfield, MI 48034 USA 03.16.09 248 355 0890 248 355 0895 Fox cwwlyhl G 2M JQk k1. IN landlord final JGA Pr j #: I; 1--209-057 I i I'' 1 I<<. yl. I DRAWINGS ISSUED FOR: O programming 8 schematic des. 02.0q,0q ❑ design dev. ❑ bidding 9 permits 03.16.09 0 construction 0landlord prelim. 02.0q.Oq IN landlord final 02.27.0q REVISIONS: Prj. no. 30q-01 I i Drown RC/ TW j Checked ALS ' Approved KIN Do not scale this print. Use figured dimensions only. Drawing title: It I REFLECTED CEILING PLAN II I Sheet no. I,c ! EQ. EQ. EQ. 4'-O" EQ. TYP. . TYP. q gog, 0 i�,i 0 1 giiij F ___, Him .f 3 f"RGED REFLECT ED rELING DIMENSION PLAN q.6I � '-- - REELEGTED GEILING PLAN LEGEND --_____ ---------- A 0 b" REGE55ED GOMPAGT FLUORESCENT OPEN DOHNL 16HT H/ EMERGENCY BATTERY PACK. REFER TO ELECTRICAL 5HEET5 FOR MORE INFO. 0 schematic des. 02,0q.0q 0 design dev. BAKER REFER TO ELEGTRIGAL 5HEET5 FOR MORE •FNF©RMATlG)N. ❑ bidding 22013 11 permits GEILING MOUNTED FIXTURE. 6.G. TO SUPPLY .1121 F_R,T. PLYWOOD BLOCKING IN GEiLiF16. REFER TO 5HEET5 F-I.I, A-2.2, A-2.3, AND A-2.4 FOR MORE INFORMATION. ❑ construction _ G Q b' REGE55ED COMPAGT FLUORESCENT OPEN DOHNLIGHT H/ EMERGENCY BATTERY PACK T REVISIONS: REGE55ED 3-CIRGUIT LI6HT TRACK - HHITE. REFER TO ELEGTRIGAL 5HEET5 233b GEILING MOUNTED FIXTURE. G.G. TO APPLY 1/2" F.R.T. PLYWOOD BLOCKING IN CEILING. REFER TO 5HEET5 F-1.1, A-2.2, A-2.3, AND A -2A FORMORE INFORMATION. D M6 fT-LI6 1T. REFER TO ELECTRICAL 5HEET5. FOR MORE INFORMATION. O b" REGE55ED METAL HALIDE DOHN.Ii i' H/ 5EMI-DIFFUSE ALUMINUM REFLECTOR. REFER TO El FG`TRIGAL 5HEET5 FCR-Mr,3RE INFO_ TI METAL E55ED TRACK HEAD, REFER TO El TRIGARIGAL 5HEET5 FOR MORE INFORMATION E 0 4 112' RE6E55ED METAL HALIDE DOHNLI6HT H/ SEMI -DIFFUSE ALUMINUM 5UNR15E OPTIC REFLECTOR. REFER TO ELEGTRIGAL 5HEET5. EA 49 L E.D. EDGE -LIT EXIT 516N W/ EMERGENGY BATTERY PACK. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. 2331 CEILING MOUNTED FIXTURE. 6.G. TO SUPPLY 1/2' F.R.T. PLYWOOD BLOCKING IN CEILING. REFER TO 5HEET5 F-1.1, A-2.2, A-2.3, AND A-2.4 FOR MORE INFORMATION. 0 REGI=f ED DDWNLISHT. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. EX2 L.ED. EXIT 516N W EMERGENCY BATTERY PACK. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. AIR DIFFUSER- 5EE MECHANICAL 5HEET5 FOR MORE INFORMATION. 4'-0" CHAIN PlOt)Pl7ED EXP05ED 51INGLE Bti FLUORESCENT. REFER TO ELEGTRIGAL 5HEET5 'OR 3'i `rfft 1ATIDN. EMI EMERGENGY LIGHT. REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. - )PPI- F Alk 5RILLE. 'i MEGHANICAL 5HEET5 FUR MORE INFORMATION. H 2'-D1x4'-O' REGE55ED FLUORE5CENT. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. � EMERGENGY LIGHT, REFER TO ELEGTRIGAL 5HEET5 FOR MORE INFORMATION. CEILING ACCESS PANEL. PI IOW COMPACT FLUORE5GENT DEGORATIVE PENDANT PROVIDED 13Y OWNER. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. SER. AIR DIFFUREFER TO MECHANICAL 5HEET5 FOR MORE INFORMATION. SPEAKER. REFER TO El EGTRIGAL 5HEET5 FOR MORE INFORMATION. 2200 GEILING MOUNTED FIXTURE. G.G. TO 5UPPLY 1/2"J F.R.T. PLYHOOD BLOCKING IN GEILING. REFER TO 5HEET5 F-1.1, A-2.2, A-2.3, AND A-2.4 FOR MORE INFORMATION.;.' OL 0" RECESSED DDWNLIGHT. REFER TO ELECTRICAL 5HEET5 FOR MORE INFORMATION. 53'-I 1/8" 50' -II 5/8" I'-3 3/ ' 4 1/4' 4'-3 -1/6' 2'-8" 1, 2'-9" 5'-O" TYP. 2'-�1' ?'-8' 4'-4 1)2" 4112 m m = DOI, F05 t Al 0 a U�I �O •0 6 1 i m Pro [99� Ci I C% IBJ' � <� I l� i I od) U, 03) 0,3 0 a a I U06' I D(--)) I Do sn moi' -'^i° V-1111 Vn PrIj �.'-A' f.'_A, �'_A. rel 4 LARGED CTS CEILING 'DAMENSION PLAN A-2.2 GGA►: r/4" = IO'at PA A' REFLEGTED GEILING PLAN 6ENERAL NOTES: A. 6.G. TO PROVIDE FIRE RETARDANT TREATED HOOD BLOCKINO 5I CURED TO `Ahl'LN[)LD M[ TAI 1-11111 01 111NI) rP (1, Ill) 1 ( )1- ( I II IFI('. I If M11 I ) r I. 1111=IIr=� B. G.G. TO PROVIDE AND IN5TALL FL1,151-1 Gal( INTEX I -ORI -15 (408-b4t-Si AG( EiS6 PANL[`� IN r! rr' llf) r.r II INr, 01 14 PAI it +II[-i.if iP r( 1 I r-1 V11)r EIGHT (8) PANELS IN 24x24 51ZE AND ARE TO BE LOCA I ED AND GO(-A;VINATFD li 114 NI F' OJ (, I HANA01 P I INAI I (k,A f ION', IO [N 1') 1 C 1-'I1Ifi G. 6.6. TO GLEAN a RE -LAMP ALL INSTALLED LIGHTING FIXfURF5 PRIOR TO TURN OVER A5 {1.LOUIRED D. LIGHTING FIXTURE LEGEND SHOHN 15 TO DESIGNATE FIX PURE 1'(PE5 AND ARE NOT TO DE CON-,)IDFRI D r,['EC,II` Iti I I(If P 'A F I-[ FG 11-11(.,A( I IrjH r FIXTURE 5PE6IFIGATION5. E. REFER TO ME( HANIGAL 5HEET5 FOR FIRE PROTECTION DIRE( TION. ALL FIRE PROTECTION 5F'WHIKLER HEAV) AFF TO B[ PLACED A5 10 I1C)f INrFRFERF h11TFl LIGHTING, HVAC AND STORE FIXTURING GOMPONENT5. F. CEILING GRID IN BACK OF HGU5E `UPPORT OFFIGE5 ARE TO BE FLUNG HITH ►112 HANGER, HIRES (11WOG) 1,11 FH ADDITIONAL HIRES AT ALL FOUR GORNER5 OF ALL LI6HT FIXTURES, DIFFUSERS, ETC. 6. ALL DIRECTIONAL EXIT SIGNS ARE INTERNALLY ILLUMINATED. H. ALL 5U5PENDED COMPONENT5 ARE TO BE 505PENDED FROM TOP CHORD OF'13AR 111111 DO NOT ATTACH SUSPENSION ATTAGHMENT5 FROM METAL ROOF DECKING (IN CONCRETE DECKING U5ED APPROVED CONCRETE FA5TENER5). I. 6.6. 5HALL PRICE A5 ALTERNATE THE PAINTING OF ALL EXP05ED 5TRU6TURAL, DUCTWORK, PIPING ETC. IN ROOMS SPECIFIED A5 "OPEN TO 6ON5TRUCTION ABOVE", PRICE DIRECTION A5 OPTION. J. 516PENDED ACOUSTICAL CEILING 5Y5TEM 15 TO BE IN WMPLtANGE WITH CC 5EGTION5_bOg3J AND 250&.2.1 AND A5TM G 035 AND A5TM G b3b. K. ELEGTRIGAL CONTRACTOR TO MAKE ALL FINAL GONNEGTION5 TO MILLHORK/FIXTURE5/GA5HARAP5 IN FIELD. L. COORDINATE LIGHTING FIXTURE LOCATIONS AND DIFFU5ER LOGATION5 WITH OTHER MECHANICAL GOMPONENT5 WITH LIGHTING BEING THE DECIDING COMPONENT. M. 5PEAKER5 PROVIDED d INSTALLED BY OTHER5. GENERAL CONTRACTOR TO PROVIDE CONDUIT, HIRES AND 5PEAKER GAN5 A5 5HOWN ON DRt4iIN675, OWNER'S VENDOR TO INSTALL FINAL HOOK UP OF SPEAKER5 AND EQUIPMENT. TENANT5 ARE PROHIBITED FROM ALLOWING MU51G OR OTHER 5OUND5 TO EMANATE FROM THEIR 5PA6E5 INTO MALL COMMON AREA OR TO ADJAGENT TENANT 5PA6E5. TENANT5 WHO GENERATE MODERATE OR HIGH SOUND LEVEL5 GREATER THAN 40 DECIBELS OR A5 OTHERH15E REQUIRED BY L.L. 5HALL IN5ULATE THEIR DEM151N6 WALL5 AND GEILIN65 AGAINST 50UW TRAN6MI55ION. THE LOCATION AND 5PEGIFIGATION OF 5Li AGOUSTIGAL PREVENTIVE METHODS MU5T 13E THOROUGHLY DETAILED ON TENANTS PLAN5 AND 15 5UBJEGT TO LANDLORD'S APPROVAL. TENANT5 5HALL NOT LOCATE 5PEAKER5 OR ANY N015E GENERATING DEVIGE5 HITHIN 12-0" OF ANY 5TOREFRONT, NOR 5HALL ANY 5PEAKER5 OR DEVIGE5 BE DIREGTED TOHARD THE STOREFRONT OR 5TORE ENTRY. TENANTS FURTHERMORE, 5HALL NOT PLACE 5PEAKER5 (INGLUDIN6 5UBWOOFER5) OR ANY N015E GENERATING DEVIGE5 INTO OR WITHIN 12'-0" OF ANY DEM151N0 WALL. N, G.G. TO MAXIMIZE CEILING HEIGHT IN ALL STOREFRONT AREA5 THAT OG( UR BELOW 5ECOND LEVEL. G.G. To MAINTAIN FLU5H CONDITION IN THE5E ( EILING AREA5, O. BOTTOM OF ALL TRACK IN CEILING TYPE '1' AREA5 ARE 70 BE MOUNTED 11'-10" AFF. P. BOTTOM OF Aj! VECORABYl PENDANT )LIGHT FIXTURES -lei all...lNO TYPE "I" .mom ARE, T19EIE MWED ll' -2" A.F.F. Q. TENANT'S GEILING HEIGHT MAY BE LIMITED BY 5TRUGTURAL OR MECHANIGAL.OB5TF4JGTl0i�6 - 6.G. TO FIELD VERIFY ALL CLEAR HEI6HT5. R. A66E55 PANELS IN CEILING MU5T BE LOCATED TO PROVIDE AGGE55 TO LANDLORD'S MEGHANIGAL EGUIPMENT PER LOCAL GENERAL GROHTH AUTHORITY. 5. SPRINKLER HEAD5 AT GYPSUM BOARD CEILINGS MUST BE FULLY RECE55E9 AND COVERED H1TH METAL PLATE5 FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN GEILIN65 TILES HHERE APPLICABLE. T. ALL NEW LOW VOLTAGE WIRING MUST BE IN CONDUIT. U. EXIT LIGHTING MUST NOT BE V151BLE FROM THE MALL VIEW. 4 I i A-2.2 , L- 0 0 0 0 0 �� l I 1 m ALX j <� EO O O O O i? O 6'-0" O 0 O 0 TYP. O ( EQ 1 O ( 0 O 0 O � tqmems!cmim®asa msu am i ® ®ress g•a c esa i ® ® reJ11VIA. ms_Q- - c r'+®�n, m� o O 0 0 o O O O O 0 0 U �- 1 O �; 1 �__��: f I. 1 U U 6 U i x�IP �Lx �EX2Cl I O O (J C) 0r7 J O o C) �) O O- O o O i O > O C J1a 4:i' - J.'i fa 1 ' NUJ in I <J C( 0 0 C) (D O O 0 O O ' O O 1 O O O 01 apy s.z Ea. 6'-0' EQ. IDc� ® .. I �x. i BMWI t,, EXIIF- EX1 -= __ ____----- =---_- - --- 0 1 U O- n -r -r I O 1 c� { e 1 OI J 1 i Iwo th) o o0 O 5 -G.- 0 1 I . ---moi` O_-6 O O O O . . Ea O o 01 LEll t 1._. _ -_ 1- 7 - _I ____ _ - - - _- - - 1 I _- -_- ..� r Z255 �i CJ 7 O 1 O O O 0 j 0 1 O I 1 1 1 1 _ I 11 O 1 0 1{ -ll l -8 I/4 i ..... :" . O1. 1 uC. c 1 I 7'-q' 1 12'-111/8' �' ioM/4" n ' y� I r' (� 1 c 1 c, c; O 1 O 0 1 O I ' 1 I O O 0 O 1 EQ.'t 0 1-1 o o 0 o y 041 o t) o I o Q o 0 0 1- -�/�v ' o ,0. " o 14 C� � 1-3 3�8 O -® __ ,,.�. ..� .� u�.. �..� .�..-ws�, � b' -O' 6'-5 5/s' . , I � � b'-5 5/8' 6'-0" 6'-8" - � �LX`� I _- ----- - - - - -- J O- f l-- - ---� -I o O O O O o O O O ----------'-------- I ; EQ, loo EQ. q -- _ _ I 1 ' 1 1 1 I I - -lo - ,� - - - - - I �{ D° �+ 0 b I/4" 0 O a 0 L I I 2 i 1.) ®� ® '� ®� J 1 1� I 4'-D" O TYP. 0 5'-1 IV 0 j o 5'-17/1° O O p O I I - P. 5 0 I I A-22 I �c moi`-� 1c ,I� ---,% O 1 0 1 0� o 0 0 0 1 O 1 O I a�r7. m©;-�«� 5'-6" i �,1, j O � o o + a o o „ n _ 0 r) n 1 I i I l I 1 1 I 1 1 i it -10 O R6 r 1 5'-2 5/s' I I I o 1 io O O rg 1 o I U --- 1 U L ;�] ;f � �> '.i._�- O U O �EXI �y 1 C� 111 1 O I O o , 0 .,,17-171-- - (l o'� ;' ,;u xaz' -arn xaca�sawwrr mca :nein as :zm m sari, :aaa •rcm neuimm sx sm s.as.t maxru s4 1 1 I 1 0 0 �' nb" 1 9'-4 31 ' 23' -Il 1/8' '-0 1/2' " O O 0 0 1 0 1 1 0 rJ ( 0 0 O I 6'-0 3/4" 1 1 I I 1 (D I I 1 1 1 1 1 1 1 1 1 I 1 Li_. I 1 �, 1 0 I I� ® m 8 U U® 1 1 4O t' 1 i I I00 I i 1 -1 Ext , I U U ®I 1 x1 1 0 0 0 1 rL 0 �- I 1 O 1 0 C, o C) o 0 1 o r1 I ® ? 1 r ca I, --�®-ems -1 O 0 o to O o o o rte' c�ri 16, i 1 `� 1 � !- - 11 ,- - -1 1 � ;, 1 � 1 � � _ � O 1 0 0 1 0 ; o 0 0 . ,�1. 42'-0" I I -- I I o o 0 o � U C�- 1, :, o 1 0 1 O E� 0 1 0 0 I I 42 3/4' I ! I EQ, �� ;D O o CJ o o o7'-q3/a"0• o I I L�� � _ .� �s ;���������= o TYP. "IGI0 o ) 0 0 0 0 0 0 0� o o o c o 11 ---------�xl---------- - I I - f-' - - - - - -- -.. O O D rn r - - - - - ILL, 4; Fra w:se g�U- m.m a�F ria Ssm srm a®ry'J a rt ama ana a ax7 rq°'t n 1( f1n r1 .% - ..- ..tea ©.._ ® .--- -- I IwGHT DIMENSIONS WALE: 1/8" a I'-0" REFER TO 5HEET A-2.1 FOR REFLECTED CEILING NOTING. 29 1 11) Inkster kaad Sutle 200 SoL11111ield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright O 2009 KEN NISCH, AIA All rights reserved Certification:-x�'t���% ,?,qn,11 xe f-3 ®EIV .1 I �J0© `,� ?{9 Cj Ole DRAWINGS ISSUED FOR.- OR:❑ 0programming 0 schematic des. 02,0q.0q 0 design dev. ❑ bidding 11 permits 03.16.0q ❑ construction 19 landlord prelim. 02.09.0q IN landlord final 02.27.0q REVISIONS: Prj. no. -209-012 Drawn RC, TIN Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: REFLECTED CEILING PLAN - LIGHTING DIMENSIONS Sheet no. mom 2 .2 Consultants: RETAIL DESIGN CONSULTANT JGA we 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248.355 0890 248 355 0895 Fax Cwrtot 0 1909 xa. i„E Ali Wit ...... J www.jgo.com JGA Pr j #: 1-209--057 1. � e ix.l 1 � LU '� d JU O tu —71p U 0 DRAWINGS ISSUED FOR: El programming ® schematic des. 02.0q.Oq LJ design dev. Q bidding ® permits 03.16.Oq D construction IN landlord prelim. 02.0q.Oq M landlord final 02.27.Oq REVISIONS: Prj. no. B -20q" 012 Drawn RGI TN Checked AL5 Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED REFLECTED CEILING FLAN GRO55 TEE @ 16" O.G. U56! 'DRYWALL 5U5PEN51ON 5Y5TEM', ARM5TRONG 'DRYWALL GRID 5Y5TEM" OR APPROVED EQUAL. (TYP) MAIN BEAM TEE ® 45" O.G., 5U5PENDE0 FROM 5TRUGTURE ABOVE. UK? 'DRYWALL 5U5PEN51ON 5Y5TEM', AR115TRONG "DRYWALL GRID 5Y5TEM" OR APPROVED EQUAL. (TYP) NOTE: G.G. TO CONFIGURE 505PEN51ON 5Y5TEM A5 REQUIRED TO ACCOMMODATE RE6E55ED L16f•fiING TRACKS, WHERE EMPLOYED. REFER TO 5HEET5 A-2.1 AND A-22 FOR MORE INFORMATION. 5/8" GYP. BD. TAPE„5PAGKLE 4 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) �L°� AT OILING SUSPENSION Yzoll 1I1 DETAIL 56ALE: b" = 1'-0' GOLD ROLLED 5TEEL AND HAT CHANNEL SUSPENDED ON #8 WIRE.- UNI5TRUT CHANNEL 5EGURED TO 5TRUGTURE ABOVE. ----- Ix BLOGKIN6 5EGURED TO UNISTRUT.- 1/4" F.R.T. PLY. WD. W/ 5/8' GYP BD. FIXED TO GOLD ROLLED 5TEEL TO SUPPORT LIGHTING TRACK. 5/8" GYP. BD. ON GOLD ROLLED 5TEEL AND HAT CHANNEL. - 6.G. TO IN5TALL "L -BEAD" AND "TEAR -AWAY" 5TRIP5 ALONG TRACK AND GYP. BD. GONNE6TION5. SEMI-REGE55ED MOUNTING 56REW. REGE55ED LIGHT TRACK. 5EE LIGHT 5GHEDULE FOR LIGHTING INFORMATION.- --- cl-chl NOTE: REFER TO SECTION #1 ON THI5 SHEET FOR ALTERNATE GEILIN6 TRACK GON5TRU( TION OPTION5. RECESSEDLI TIN I L . 56ALE: 3" = 1'-0' cl-trck-Igt-re55d MAIN BEAM TEE ® 48' O.G., SUSPENDED FROM 5TRU6TURE ABOVE. USG "DRYWALL 5U5PEN51ON 5Y5TEM", ARM5TRONG "DRYWALL GRID 5Y5TEM' REFER TO' OR APPROVED EQUAL. (TYP) REFER TO 5/8" GYP. BD. TAPE, SPACKLE I GONTINUOU5 2"x2" BREAK 5HEET5 A-2.1 I 4 5AND A5 REQUIRED TO 5HEET5 A-2.1 03.16.Oq ❑construction AND A-22 AND A-22 AND A-22 AND A-22 ACCEPT PAINT FIN15H. (TYP) -- '-�- -- ----T-- METAL ANGLE A5 REQUIRED ' G.G. TO INSTALL "L -BEAD' AND -1 "TEAR -AWAY" 5TRIP5 ALONG TRACK AND GYP. BD. GONNEGTION5. NOTE: RE( E55ED LIGHT TRACK. 5EE REFER TO 5E6TION #1 ON THI5 LIGHT 5GHEDULE FOR LIGHTING SHEET FOR ALTERNATE GEILIN6 INFORMATION. TRACK AND TRACK GONSTRUGTION OPTIONS. 5UPPORTIN6 TEE TO BE PLACED @ 48" O.C. (TYP) RECD L1W""`TIN"G TRACK0 IN SUSP. GYP. CLNG, 5GALE: 3" = 1'-0' c1-trck-I9t-rc55d EXI5TIN6 (2) b°x166A. TRACK GRANNEL5 ® 5'-4' O.( . IJOXED HEADER.. THREAD AANOER5 96PBPED FROM P1000H.tA15TRUT CR -EQUAL 5ECVRED TO EX15T1W5 (2)�:6"x166A. + r G1MEL5 0'S'-4' 0f,.'80%El? tf-ACf P, M O001 3 I TRUT OR E(7JAL 2" HtG4L r �--- A04 TRACK LIGHTING ?"ITED TO PIOOOH3 UN15TRUT OR EQUAL ABOVE. LI (iflT I RNG TRACK UNI T U` SCALE: 3' = I' -O' cl-trc#;-Jgt-a,�strt _ REFER TO SHEET A-2.1 FO CEILINGl-EIGHT NOTE: GEILIN6 GON5TRUGTION 5HO MAY NOT MATCH ACTUAL GE GON5TRIJGTION, REFER TO! AND A-22 FOR ACTUAL GEI GOIjTRUGTION TYPE ON BO WALL HEADER. REFER TO 5HEET5 A-3.1, A FOK GLILIN65 56ALE: 1112" = 1'-0' WIDTH TO MATCH ADJACENT WALL, U.O.N. REFER TO 5HEET5 A-I.I AND A-2.1 CEILING cl-head DIAGONAL BRA( IN6 TO FLOOR 13EAM5/GOMP051TE DECK ABOVE, MU5T BE APPROVED BY MALL OPERATIONS, 48" O.G. MAX. FIREPROOFING TO BE APPLIED AT BRACING GONNE6TION5. 1 1/2" COLD ROLLED STEEL CHANNEL, 5U5PENDED WITH #b HANGER WIRE FROM 5TRUGTURE ABOVE. CORNER ANG1LE5 A5 REQUIRED. REFER TO SHEET A-2.1 FOR GEILIN6 HEIGHT 5/8" GYP. W. ON 1/8' HAT TRACK 5 F JF D TO I I/2u COLD RO__F D 5TEEL HNN__ SUSPEND_ DWITH #5 HANGER WIRE FROM 5TRUGTURE ABOVE. TAPE, 5PA6KLE 4 5AND A5 REQUIRED TO A66EPT PAINT FIN15H. (TYP) REFER TO 5HEET5 A-2.1 AND A-22 FOR CEILING C0145TRUCTION INFORMATION. 5/5" GYP. W. ON METAL 5TUD FRAMING, OR OVER CONTINUO)" BLOGKING (WHERE PRE5ENT) REFER TO ARCHITECTURAL FLOOR PLAN 5HEET A-I.I FOR WALL TYPE. CORNER BEAD ALL OUTSIDE GORNER5. TAPE, 5PA6KLE d 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) SUSPEND METAL GEILIN6 FRAMING 5Y5TEM FROM 5TRUGTURE ABOVE PER REQUIREMENTS OF APPLIGA13LE GODE5. (TYP) 2x4 FR.T. 50PPORT FRAMING 2xb F.R.T. WOOD FRAMING NOTCHED TO 51T OVER GOLD ROLLED 5TEEL. 1 1/2' GOLD ROLLED 5TEEL @ 48" O.G. MAX. (TYP) 3/4" F.R.T. PLYWOOD BETPEEN HAT CHANNEL 5EGURED l'0 WOOD FRAMING. 1V HAr CHANNEL 0 Ib" O.G. MAX. (TYP) STANDARD CEILING HANGING N SECTION 5GALE, b" = 1'-0' ci-ply-blck abPEND METAL CEILING FRAMING 5`Y'5TEM .f-RO H 5T3? 3GTtF A5WE 'PER REQUIR& ERT5r; F APPLICABLE .COV 5. (TYP) 2x4 F.R.T. SUPPORT FRAMING. 2xb F.R.T. WOOD FRAMING NOTCHED TO 51T OVER COLD ROLLED 5TEEL. 1 1/2' GOLD ROLLED 5TEEL @ 4b' O f,. MAX: (TYP) i/bD mr cvma 5/&' GYP BD. ON 3/4' F.R.T. PLYWOOD 5EGURED TO 11W 14AT CHANNEL. CEILING HANGING CTI N GALE: b' = 1'-0' cl-ply-blck-drop In DIAGONAL BRAGING A5 REQUIRED. (TYP) 5/b' OYP. 80.'.014 1/6 1 'I RAT, TRACK, :5ECV;?.I^D TO 11/2' COD ROLLED 5TEEL CHANNEL 96PENDED WITH #5 K46 -FR WIRE FROM STRUCTURE ABOVE. TAPE, 5PAGKLE 4 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) 5/S" GYP. SD. OVER 6ONTINUOU5 1/2" F.R.T. PLYWOOD BLOCKING ON 3 5/8' 16 GAUGE MIN. STRUCTURAL METAL 5TUD5 e !b" O.G. CORNER BEAD ALL OUT5IDE GORNER5. TAPE, 5PAGKLE 4 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) REGE55ED LIGHTING SHOWN DASHED. REFER TO 5HEET5 A-2.1 AND A-22 FOR EXACT LOGATION5 AND MORE INFORMATION. @ 48" D.G. MAX. (TYP). REFER TO' REFER TO REFER TO REFER TO REFER TO �. GONTINUOU5 2"x2" BREAK 5HEET5 A-2.1 5HEET5 A-2.1 5HEET5 A-2.1 5HEET5 A-2.1 5HEET5 A-2.1 03.16.Oq ❑construction AND A-22 AND A-22 AND A-22 AND A-22 AND A-22 02.2/.Oq lo 7 REFER TO 5HEET5 A-2.1 AND A-22 DIAGONAL BRAGING A5 REQUIRED. (TYP) 5/b' OYP. 80.'.014 1/6 1 'I RAT, TRACK, :5ECV;?.I^D TO 11/2' COD ROLLED 5TEEL CHANNEL 96PENDED WITH #5 K46 -FR WIRE FROM STRUCTURE ABOVE. TAPE, 5PAGKLE 4 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) 5/S" GYP. SD. OVER 6ONTINUOU5 1/2" F.R.T. PLYWOOD BLOCKING ON 3 5/8' 16 GAUGE MIN. STRUCTURAL METAL 5TUD5 e !b" O.G. CORNER BEAD ALL OUT5IDE GORNER5. TAPE, 5PAGKLE 4 5AND A5 REQUIRED TO ACCEPT PAINT FIN15H. (TYP) REGE55ED LIGHTING SHOWN DASHED. REFER TO 5HEET5 A-2.1 AND A-22 FOR EXACT LOGATION5 AND MORE INFORMATION. @ 48" D.G. MAX. (TYP). FOR: ❑ programming IN schematic des. 02.0q.Oq GONTINUOU5 2"x2" BREAK ❑ bidding N permits 03.16.Oq ❑construction 9 landlord prelim. 02.Oc1.0q 91landlord final 02.2/.Oq �' v METAL ANGLE A5 REQUIRED TO FORM CORNER. i� HAT CHANNEL @ I6' c-V O.G. MAx. (TYP). - - -- ---- ------�- -- -- A-- - IF -P - -.-_---.------------ - _ _ - IF I I - _ Y'. • •'Y. - L� LIGHTING TRACK HOUSING, TIED TO 5/5" GYP. BD. (TYP). CEILING FRAMING PER MANJFA6TURER5 5PEGIFIGATIONS. ELECTRICAL CONTRACTOR TO 5EGURE AND ELECTRICALLY GONNEGT LIGHT TRACK TO HOUSING (TYP). GOLD ROLLED 5TEEL CHANNEL WITH HAT GHANNEL5,5U5PENDED TO DEGKIN6 BY #8 WIRE. CONTINUOUS 3/4" F.R.T. PLYWOOD BLOCKING, 5EGURED TO METAL GHAT` WITHLOURTER-Sl KV, YRF 50" GYP. BD. 5EGURED T PLYWOOD BLOCKING. TA 5PAGKLE 4 5AND A5 RE( TO ACCEPT PAINT FIN15H. "CEILING AIL SCALE: b" = 1'-0" cl-ply-glz "-U56 GEILING/WALL CONTROL ..JOINT. REFER TO SHEET A-2.1 FOR LOGATION5. 56ALE: N.T.5. cl-cntrl jt J0•AC-( PT,,PAINT- FIR 5H..(TYP, .) 4 CEILING ACCESS PANEL JOINT SECTION A-21 5GALE: FULL cl-htch 29110 Inkster Road Suite 200 Southfield, Ml 48034 USA 248 355 0890 248 355 0895 Fax i. Copyright Q 2009 KEN NISCH, AIA All rights reserved Certification: �A- P� G•• A ,p. 0 ff' POPQ P7PP� �N%,�GV�& Q v AR k -Ob 0e, 4 00.0000 r v% Consultants: RETAIL DESIGN CONSULTANT JGA INC 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox C.9,r10l 0 200 SGA, Mc m .�:, � www.jgo.com JGA Prj #: 1-N209--057 T DRAWINGS ISSUED FOR: ❑ programming IN schematic des. 02.0q.Oq ❑ design dev. ❑ bidding N permits 03.16.Oq ❑construction 9 landlord prelim. 02.Oc1.0q 91landlord final 02.2/.Oq REVISIONS Prj. no. -0q-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: CEILING DETAILS Sheet no. rte' AJLL.-.EXPOSED 6TRUCTI0N VI5IBLJE TO 5ALE5 FLOOR IN GEILIN6 CAVITY TO BE PAINTED BLACK. NOTE: REFER TO CEILING DETAIL #"1 ON THIS SHEET FOR 5TOREFRONT D15PLAY CEILING GON5TRUCTION INFORMATION_ NEW GYP. BD. SOFFIT CON5TRUCTION AT STOREFRONT ENTRY. ALL EXP05ED 51DE5 TO HAVE LEVEL 5 GYP. BD. FINISH. G.G. 70 PAINT ALL GYP. BD. TO MATCH ADJACENT WALL FIN15H. C7YP. ED. TO EXTEND I' -I I/2' FROM ADJACENT GEILINCi CON5TRUGTION A5 5HOWN. LIT GAP OPTIONAL. L16K 11)BE5 CAN BE PLACED IF GAF 15 CONNECTED TO CEILINF DETAIL #2 ON TH15 SHEET. REFER TO 5HEET5 A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION AND LOGATION5. FLOURE5GANT TUBE TO BE ATTACHED TO F.R.T. BLOGKIN6 WITH CLIPS 5UPPLIED BY LIGHTING MANUFACTURER. REFER TO 5HEET5 A-2.1, A-2.2, AND A-23 AND ELECTRICAL DETAU-5 FOR MORE INFORMATION. CEILING GON5TRUGTION. REFER TO 5HEET A-2.1 FOR EXACT CON5TRUCT ION TYPE AND CEILING HEIGHT. c I-hm-Z7c�-gap-entry WRAP 5/5' GYP. EV. AROUND EXP05ED I I I CONSTRUCTION OF FLOATING CEILING I A5 5HOWN. VERTICAL FACE TO BE LEFT EXPOSED. OPTIONAL 5TA66ERE1? LIGHT TUBES. REFER TO 5HEET5 A-2.1, A-22, AND A-23 FOR EXACT LOCATIONS. Ili REFER TO 5HEET A-2.1 FOR CEILING J CON5TRUGTION INFORMATION AND CEILING f 113/4' HEIGHT. I m 6.6. TO WRAP GYP. BD. ON TH15 VERTICAL FACE. 1'-3 3/4" L16HT FIXTURE IN FLOATING CEILING SHOWN DASHED. REFER TO 5HEET5 I'-&" MIN. REFER TO 5HEET5 A-2.1, A-2.2, AND A-23 FOR EXACT A-2.1, A-22, AND A-23 LOCATIONG AND MORE INFORMATION. le 1nCEILING CONSTRX"l-ION @ FLOATINGCEILING t 2.1 SCALE: I'= 1'-O' cl-hm-2b-drop-drag LANDLORD EVLKHEAD ABOVE. RE6E55ED LIGHT TRACK IN STOREFRONT 015PLAY ),AINDOW Sf5TEM. GEILIN6 GON5TRUGTION. REFER TO 5HEET A-2.1 FOR EXACT CON5TRLYTION TYPE AND GEILIN6 HEIGHT. 'REVEAL GHA14a. 5TOREFRONT GLAZING 5Y5TEM. REFER TO STOREFRONT 5HEET5 FOR MORE INFORMATION. LEA5ELINE. ALTERNATE CEfl-'JNGGAP__@ DISPLAY WIN' SCAt FE: CEILING AT SCALE: I' - 1'-0" CEILING GON5TRUGTION. REFER TO SHEET A -lb FOR FIN15H INFORMATION AND SHEET A-2.1 FOR EXACT 6ON5TRUGTION TYPE AND CEILING HEIGHT, WALL CON5TRXTION. REFER TO 5HEET5 A-I.I, A-12, A -I3, A-1.4, AND A715 FOR EXACT CONSTRUCTION TYPE AND 5HEET A -lb FOR FINISH INFORMATION. LANDLORD BULKHEAD ABOVE. GEILIN6 CON5TRU6TION. REFER TO 5HEET A-2.1 FOR EXACT CON5TRU( TION TYPE AND CEILING HEIGHT. RECE55ED LIGHT TRACK IN STOREFRONT 015PLAY WINDOW 5Y5TEM. 5TOREFRONT GLAZING 5Y5TEM. REFER 70 5TOREFRONT 5HEET5 FOR MORE INFORMATION. LEA5ELINE. WALL GON5TRU6TION. REFER TO 5HEET5 A-I.I, A-1.2, A-1.3, A-1.4, AND A-15 FOR EXACT GON5TRUGTION TYPE. cl-hm-24-no-gap WALL CON5TRJGTION. REFER TO 5HEET5 A -I.1, A-1.2, A-13, A-1.4, AND A-15 FOR EXACT CON5TRUCTION TYPE. i i f I ALL EXPO5ED GONS RUGTION V151BLE TO 5ALE5 FLOOR IN GEILIN6 CAVITY TO BE PAINTED BLACK. NEW GYP. BD. SOFFIT GON5TRU6TION 6-' AT WARDROBE. ALL EXP05EP 51DE5 TO HAVE LEVEL 5 GYP. BD. FIN15H. 6.G. 70 PAINT ALL GYP. BD. TO MATCH AD.IAGENT WALL FIN15H. GYP. _- _ BD. TO EXTEND 2'-b' FROM 130TTOM OF SOFFIT A5 514". ILII/8" I I D=� GEILIN6 GON5TRUGTION. REFER 1/4 TO SHEET A-2.1 FOR EXACT GON5TRUCTION TYPE AND CEILING HEIGHT. H4 M WARDROBE FIXTURE SHOWN BELOW: REFER TO PLANS FOR EXACT LOGATION. 1 1CEILING A-4.2 A-2.1 5GALE: I" = 1'-0" cl-hm-2l-wrdrb-gap WALL GON5TRUGTION. REFER TO 5HEET5 A-I.I, A-1.2, A-13, A-1.4, AND A-15 FOR EXACT GON5TRUGTION TYPE. FLOURE5GANT TUBE TO BE ATTACHED TO F.R.T. BLOCKING WITH GLIP5 5UPPLIED BY LIGITING MANUFACTURER. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND ELEGTRIGAL DETAIL5 FOR MORE INFORMATION. GEILIN6 GON5TRUGTION. REFER TO 5HEET A-2.1 FOR EXACT GONSTRUGTION TYPE AND CEILING HEIGHT. HdM FREE5TANDING FRAME FIXTURE. G.G. TO PROVIDE F.R.T BLOCKING IN CEILING. REFER TO PLAN5 FOR EXACT LOCATION. PAINT GYP. BO. WALL TO BOTTOM OF METAL COVER PLATE. REFER TO 5HEET A-I.b FOR FIN15H. CEILING RUCTION DISPLAY WIN 2 LN d A L LN a A-4.2 A-2.1 SCALE: I' = I' -O" cl-hm-25-d5pIy- mdse A-2.1 5GALE: I° = 1'-D' cl-hm-224ramme5-gap-Ilght CEILING WALE: -1' =A' -J' PAINT ALL EXP05ED GON5TRUGTION V151BLE TO 5ALE5 FLOOR IN BLACK. :GEIlINIC� ,CONS7RUGTION. REFER TO 5HEET A -I.6 FOR FIN15H INFORMATION AND 5HEET A-2.1 FOR EXACT GON5TRUGTION TYPE AND GEILIN6 HEIGHT, ADJACENT CEILINGS c I-hm-2b-gap-btwn-(.Ings ALL EXPOSED GON5TRUGTION V151BLE TO 5ALE5 FLOOR IN CEILING CAVITY TO BE PAINTED BLACK. REFER TO CEILING DETAIL #1 ON TH15 5HEET FOR 5TOREFRONT DISPLAY GElLAIG GON5TRUGTION INFORMATION. NEW GYP. BD. 5OFF1T CON5TRUGTION AT 5TOREFRONT ENTRY. ALL EXPOSED 51DE5 TO HAVE LEVEL 5 GYP. BD. FINISH. G.G. TO PAINT ALL GYP. BD. TO MATCH ADJACENT WALL FIN15H. GYP. BD. TO EXTEND 1'-1 1/2" FROM ADJACENT GEILIN6 GON5TRUCTION A5 SHOWN. LIT GAP OPTIONAL. LIGHT TUBES CAN BE PLACED IF GAP 15 CONNECTED TO GEILIN6 DETAIL #2 ON TH15 5HEET. REFER TO 5HEET5 A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION AND LOGATION5. FLOURE5GANT TUBE TO BE ATTACHED TO F.R.T. BLOCKING WITH GLIP5 %PPLt"rt7 BY LIGHTING MANUFACTURER. REFER TO 5HEET5 A-2.1, A-22, AND A-2.3 AND ELEGTRIGAL DETAIL5 FOR MORE INFORMATION. CEILING GON5TRUGTION. REFER TO 5HEET A-2.1 FOR EXACT GON5TRUGTION TYPE AND CEILING HEIGHT. A-2-1 SGALI=: I" = I'-tOt' cl-hm 27-gap-entry-t�pty-windw I WALL CON5TRUGTION. REFER TO 5HEET5 A-1.1, A-12, A-13, A-1.4, AND A-15 FOR EXACT GON5TRUGTION TYPE. PAINT GYP. BD. WALL FROM ADJACENT CEILING HEIGHT TO 1'-0" ABOVE ADJACENT CEILING HEIGHT. REFER TO 5HEET A -lb FOR FINISH. LIT GAP OPTIONAL. LIGHT TUBES GAN BE PLACED IF GAP 15 GONNEGTED TO CEILING DETAIL #2 ON TH15 5HEET. REFER TO 5HEET5 A-2.1, A-2.2, AND A-2.3 FOR MORE INFORMATION AND 1_06A710N5. FLOURE5GANT TUBE TO BE ATTACHED TO F.13.T. 13LOCKIN6 WITH CLIPS SUPPLIED BY LIGHTING t�IANUFAGTURER. REFER TO 5HEET5 A-2.1, A-22, A-2.3, AND ELEGTRIGAL DETAIL5 FOR MORE INFORMATION. CEILING GOW:)TRUGTION. REFER TO 5HEET A-2.1 FOR EXACT 6ON5TRUGTION TYPE AND CEILING HEIGHT. c I -tun -23 -gap -light PAINT ALL EXP05ED GON5TRUCTION V151BLE TO 5ALE5 FLOOR IN BLACK. LIT GAP OPTIONAL, LIGHT TUBE5 CAN BE PLACED IF GAP 15 CONNECTED TO 6EILIN6 DETAIL #2 ON TH15 5HEET. REFER TO 5HEET5 A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION AND LOGATION5. FLOURE5GANT TUBE TO BE ATTACHED TO F.R.T. BLOGKIN6 WITH GLIP5 50PPLIED BY LIGHTING MANUFACTURER. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND ELEGTRIGAL DETAIL5 FOR MORE INFORMATION. CEILING 6ON5TRUGTION. REFER TO MEET A-2.1 FOR EXACT GoN5TRUGT1oN TYPE AND CEILING HEIGHT. 56ALE: I" = 1'-0" c I-hm-23a-gap- I fight -ad jt -c Ing 29110 Inkster (toad Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Copyright 0 2009 KEN NISCH, AIA All rights reserved Certification:%����'�' Cj �, wo 1. �'�e� Qom., o A E; �loao'D e030�� i Consultants: RETAJL RESIGN CONSULTANT ii JGA w, 29110 Inkster Road Suite 200 Southfield, MI 48034 USA s 248 355 0890 248 355 0895 Fax cw), nt 0 sone .c.>. Inc 'km.'_yW www.jgo.com JGA Pr1 #. 1-209--057 II I 'i Ii I; DRAWINGS ISSUED FOR: Q programming 11 schematic des. 02.oq.oq ❑ design dev. ❑ bidding IN permits 03.,16.0q ❑ construction N landlord prelim. 02.0q.0q 0landlord final 02.27.001 REVISIONS: r; i I j r Prj. no. 8-209-012 Drawn RC, ,TW Checked ALS Approved KN Do not scale this print. Use i figured dimensions only. Drawing title: II , CEILING DETAILS Sheet no. now A, LZI a WA M Lu z. pC 0 CV Lu Lu z 0 Lu 1 1 I °T IO ELEVATION A_l.l SCALE: 114" = I'-0" sheet ,file D91 2 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" D-1 1 SCALE: I!4° 1'-0” sheet file 3 (53 Z6 SCALE: 1/4' = 1'-0° 'mom 5 131 141 SCALE: I14u = 9'-0° OPEN TO 5ALE5 FLOOR BEYOND.— Ek s ry 3 sheet file sheet file Lu 0 LL N w w O a-- w ,_n sheet Tile 4 4 ELEVATION KEY NOTES 1 NEW 5TOREFRONT ENTRY AND PI..AZINO 51(5TEM, REFER TO 5HEET5 A-02, A41, AND A-4.2 FOR MORE INFORMATION. 5TOREFRONT 516N. REFER TO 5HEET5 A-4.1 AND A-49 FOR MORE INFORMATION. l a l WALL BASE. REFER TO SHEET A -I.6 FOR MORE INFORMATION. ��--�—� LINE OF NEW GYP. BD. GEILING REFER TO 5HEET5 A-2.1, A-22, A-2.3, A-2.4, AND A-25 FOR [4] MORE INFORMATION. GYP. BD. WALL. REFER TO 5HEET5 A-1.1, A-12, A-13, A-1.4, A-15, A-1.6, AND A-5.1 FOR FINISHES AND MORE INFORMATION. NEW WARDROBE FIXTURE. REFER TO 5HEET5 F-1.1, F-12, F-13, F-1.4, F-15, A-I.I, A-12, A-13, A-1.4, AND A-1.5 FOR MORE INFORMATION. 6.6. TO LEAVE 1/8" CAP BETWEEN WALL AND FIXTURE. 5URF-A( E HOUNT•ED 5TANDAI W+QF',W 6,010TION. RESER TO SHEETS F-1.2 AND A-5.5 FOR MORE INFORMATION. aIS NEW FRAMES WALL FIXTURE. REFER TO 5HEET5 F-I.I, F-12, F-13, F-1.4, F-15, A-1.1, A-1.2, A-1.3, A-1.4, A-15, A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION. FqDASHED LINE INDIGATE5 APPROXIMATE LOGATION OF 6A5HWRAP. REFER TO PLANS AND 5HEET F-1.1 FOR EXAGT LOCATION AND MORE INFORMATION. nio WALL PAINT TO EXTEND TO TH15 LINE BEHIND FIXTURE WALL PANELS ONLY (TYPj. 11 LINE OF HEADER. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. n12WALL FIXTURE. G.G. TO PROVIDE F.R.T. BLOCKING IN WALL. REFER TO SHEET F-1.1 FOR MORE INFORMATION. F13 COLUMN BUILD OUT. REFER TO 5HEET5 F-I.I, A-1.1, A-12, A-13, A-1.4, A-15, AND A-a.l FOR MORE , 3 INFORMATION. 14 STOREFRONT DISPLAY PLATFORM. REFER TO 5HEET5 A-4.1 AND A-4.2 FOR MORE INFORMATION. 15 FLOATING GEILING SHOWN IN BAG1<61ROUND/FORE6ROUND. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. Fl(o]FLOOR TO GEII_NIG FIXTURE. C.G. TO PROVIDE F.R.T. PLYWOOD BLOGKIN6 IN ADJAGENT GEILIN6. REFER TO 5HEET5 F-1.1, F-0, F-13, F-1.4, F-15, A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. 4 Il DRAWINGS ISSUED FOR: ❑ programming � NJ N1 %IN m = 11 permits 03.16.0q ❑ construction N landlord prelim. a 02.27.Oq 5 m E— LU Ce LL- ku LU Lu ^T' :L 14 - � � OPEN TO 5A! F5 FLOOR BEYOND.Q1 ,,, F OPEN TO 5ALE5 FLOOR BEYOND. ,, `vau a Q -OPEN TO r i _ m < �- Lu OPEN TO 5ALE5 FLOOR BEYOND. ,, Lu ic '- w FITTING — Lu T O i Lu Lu LL ROOMS dli 11 LL 5 ni OPEN TO 5ALE5 z _ BEYOND.- _ m Q FLOOR BEYOND.„, rm mLu aJ cp Lu d) XF QL ` LL Lu D91 2 INTERIOR ELEVATION SCALE: 1/4" = 1'-0" D-1 1 SCALE: I!4° 1'-0” sheet file 3 (53 Z6 SCALE: 1/4' = 1'-0° 'mom 5 131 141 SCALE: I14u = 9'-0° OPEN TO 5ALE5 FLOOR BEYOND.— Ek s ry 3 sheet file sheet file Lu 0 LL N w w O a-- w ,_n sheet Tile 4 4 ELEVATION KEY NOTES 1 NEW 5TOREFRONT ENTRY AND PI..AZINO 51(5TEM, REFER TO 5HEET5 A-02, A41, AND A-4.2 FOR MORE INFORMATION. 5TOREFRONT 516N. REFER TO 5HEET5 A-4.1 AND A-49 FOR MORE INFORMATION. l a l WALL BASE. REFER TO SHEET A -I.6 FOR MORE INFORMATION. ��--�—� LINE OF NEW GYP. BD. GEILING REFER TO 5HEET5 A-2.1, A-22, A-2.3, A-2.4, AND A-25 FOR [4] MORE INFORMATION. GYP. BD. WALL. REFER TO 5HEET5 A-1.1, A-12, A-13, A-1.4, A-15, A-1.6, AND A-5.1 FOR FINISHES AND MORE INFORMATION. NEW WARDROBE FIXTURE. REFER TO 5HEET5 F-1.1, F-12, F-13, F-1.4, F-15, A-I.I, A-12, A-13, A-1.4, AND A-1.5 FOR MORE INFORMATION. 6.6. TO LEAVE 1/8" CAP BETWEEN WALL AND FIXTURE. 5URF-A( E HOUNT•ED 5TANDAI W+QF',W 6,010TION. RESER TO SHEETS F-1.2 AND A-5.5 FOR MORE INFORMATION. aIS NEW FRAMES WALL FIXTURE. REFER TO 5HEET5 F-I.I, F-12, F-13, F-1.4, F-15, A-1.1, A-1.2, A-1.3, A-1.4, A-15, A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION. FqDASHED LINE INDIGATE5 APPROXIMATE LOGATION OF 6A5HWRAP. REFER TO PLANS AND 5HEET F-1.1 FOR EXAGT LOCATION AND MORE INFORMATION. nio WALL PAINT TO EXTEND TO TH15 LINE BEHIND FIXTURE WALL PANELS ONLY (TYPj. 11 LINE OF HEADER. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. n12WALL FIXTURE. G.G. TO PROVIDE F.R.T. BLOCKING IN WALL. REFER TO SHEET F-1.1 FOR MORE INFORMATION. F13 COLUMN BUILD OUT. REFER TO 5HEET5 F-I.I, A-1.1, A-12, A-13, A-1.4, A-15, AND A-a.l FOR MORE , 3 INFORMATION. 14 STOREFRONT DISPLAY PLATFORM. REFER TO 5HEET5 A-4.1 AND A-4.2 FOR MORE INFORMATION. 15 FLOATING GEILING SHOWN IN BAG1<61ROUND/FORE6ROUND. REFER TO 5HEET5 A-2.1, A-22, A-23, AND A-2.4 FOR MORE INFORMATION. Fl(o]FLOOR TO GEII_NIG FIXTURE. C.G. TO PROVIDE F.R.T. PLYWOOD BLOGKIN6 IN ADJAGENT GEILIN6. REFER TO 5HEET5 F-1.1, F-0, F-13, F-1.4, F-15, A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. 4 Il 1 T N_ LL N Lu Lu IN DRAWINGS ISSUED FOR: ❑ programming � FJ ❑ design dev. m = 11 permits 03.16.0q ❑ construction N landlord prelim. a 02.27.Oq 5 m E— LU Ce LL- ku LU Lu ^T' :L 14 - � � OPEN TO 5A! F5 FLOOR BEYOND.Q1 ,,, F OPEN TO 5ALE5 FLOOR BEYOND. ,, `vau a Q r i _ m < �- Lu OPEN TO 5ALE5 FLOOR BEYOND. ,, - w — Lu T i Lu Lu LL dli 11 1 T N_ LL N Lu Lu IN DRAWINGS ISSUED FOR: ❑ programming � FJ ❑ design dev. m = 11 permits 03.16.0q ❑ construction N landlord prelim. a 02.27.Oq INTERIOR L TI SCALE= 114° = 1'-0" 1u 6 11 N ynC�J 11 I INTERIOR ELEVATION SCALE: 1/4" = 1'-0" U sheet file sheet file SCALE: I!4° - 1'-0" _ DRAWINGS ISSUED FOR: ❑ programming T_F 02.0q.Oq ❑ design dev. O bidding 11 permits 03.16.0q ❑ construction N landlord prelim. 19landlord final 02.27.Oq � LU Ce LL- ku LU Lu ^T' :L 14 - � � Lu -r CK `vau a Q r i _ m < �- Lu OPEN TO 5ALE5 FLOOR BEYOND. ,, - w — Lu T i Lu Lu LL dli 11 i LC SCALE: 114' _ 1'-0" sheet file REVISIONS: j. no. 8-209-012 awn RC, TW ecked AL5 proved KN not scale this print. Use orad dimensions only. awing title: INiEltii� eat no. gra r j DRAWINGS ISSUED FOR: ❑ programming N schematic des. 02.0q.Oq ❑ design dev. O bidding 11 permits 03.16.0q ❑ construction N landlord prelim. 02.0q.0q 19landlord final 02.27.Oq LU Ce LL- ku LU QLu - � U_o J `vau a Q REVISIONS: j. no. 8-209-012 awn RC, TW ecked AL5 proved KN not scale this print. Use orad dimensions only. awing title: INiEltii� eat no. gra r j DRAWINGS ISSUED FOR: ❑ programming N schematic des. 02.0q.Oq ❑ design dev. O bidding 11 permits 03.16.0q ❑ construction N landlord prelim. 02.0q.0q 19landlord final 02.27.Oq REVISIONS: j. no. 8-209-012 awn RC, TW ecked AL5 proved KN not scale this print. Use orad dimensions only. awing title: INiEltii� eat no. gra r j LU tr LL_ N QJ LL LLJ ct� SCALE: 1/4' = 1'-0" rl ELEVATION KEY NOTES ❑NEW 5TOREFRONT ENTRY AND,GLAZ46 5Y5TEM, REFER TO 5HEET5 A-02, A-4.1, AND A-42 FOR -MORE INFORMATION. 2 5TOREFRONT 516N. REFER TO 5HEET5 A-4,1 AND A-42 FOR MORE INFORMATION. L 21 HALL BASE. REFER TO SHEET A-1.6 FOR MORE INFORMATION. %I 'i % :E I% Enih (b LINE OF NEW GYP. BD. ,( EIL1416 REFER TO SHEETS A-2.1, A-2-2, A-23, A-2.4, AND A-2.5 FOR to LU -OPEN TO 29110 Inkster Road iu- MORE INFORMATION. FITTINC2 o LL Suite 200 ROOMS U_ cv GYP. 131). HALL. REFER TO 5HEET5 A-1.1, A-1.2, A-13, A-1.4, A-15, A-1.6, AND A-5.1 FOR FIN15HE5 ry - ❑❑ BEYOND AND MORE INFORMATION. Southfield, MI 48034 USA 5 :6 5 m—TE 248 355 0890 �- ❑� m -_ m - _ LU NEW WARDROBE FIXTURE. REFER TO 5HEET5 F-1.1, F-1.2, F-13, FAA, F-1.5, A-1.1, A-12, A-13, A -IA, dj LU ui AND A-15 FOR MORE INFORMATION. G.G. TO LEAVE 1A)" GAP BETWEEN WALL AND FIXTURE. 248 355 0895 Fax Fj_ 'Ci5LRFA6E.,MGWTW j5TAWARF,,6 W PUPjAff, 60WATtON. REFER TO 5HEET5 F-12 AND A-55 FOR UA ly Lt- MORE INFORMATION. Copyright @ 2009 LU L LL KEN NISCH, AIA L� �� ❑ 8 NEW FRAME5 HALL FIXTURE. REFER TO 5HEET5 F-1,11, F-12, F-1.3, F -IA F-1.5, A-1.1, A-1.2, A-1.3, All rights reserved - ❑❑ A-1.4, A-15, A-2.1, A-22, AND A-23 FOR MORE INFORMATION. cti JX. Certification: VA 3 k, 3 3 ❑ PA5HEI? LINE INDICATE5 APPROXIMATE LOGATION OF ( A5HKRAP. REFER TO PLAW5 AND 5HEET F -IJ FOR.EXA6T.LQGATlONAtm MORE -INFORMATION. 1 N 0WALL PAINT TO EXTEND TO TH15 LINE BEHIND FIXTURE WALL PANELS ONLY (TYP). 1-1 I TERIOR ELEVATION TION. r2A INTERIOR ELEVAT10" 5heet file 11 LINE OF HEADER. REFER, TO 5HEET5 A-2.1, A-2.2, A-23, AND A -2A FOR MORE INFORMA sheet file 5C -ALE- 114' 1'-0" sheet file SCALE: VA' V-00 1_WALL FIXTURE. G.G. TO PROVIDE F.P.T. BLOGKINC2 IN WALL. REFER TO 5HEET F-1.1 FOR MORE 121 INFORMATION. ARS (306 nCOLUMN BUILD OUT. REFER TO 5HEET5 F-1,1, A-1.1, A-12, A-13, A-1.4, A-1.5, AND A-5.1 FOR MORE % 4 4 n4 F,❑31INFORMATION. 4 � [14] 5TOREFRONT P15PLAY PLATFORM. REFER TO 5HEET5 A-4.1 AND A-4.2 FOR MORE INFORMATION. :VAI 2 W4" 2 3/4" 2 W4" F_ -2.1, A-2.2, A-23, ANTFLOATIN6 GEILIW_-.,5HOWN IN BACK6ROUND/FOREC7ROUND. REFER TO %IEET5 A (�'at�`� ❑ AND A-2.4 FOR MORE INFORMATION. LU ------- tf) 10 10❑ FIXTURE. O.G. TO PROVIDE F.R.T. PLYWOOD BLOCKING IN ADJAGENT GEILINC7. Consultants: ri i FLOOR TO GEILNIG U_A-55 j REFER TO 5HEET5 F-1.1, F42, F-13, F-1.4, F-15, A-2.1, A-2.2, A-23, AND A -2A FOR MORE MAIL DESIGN CONSULTANT OPEN TO 5ALE5daINFORMATION. 5 Lu ❑ JGA IRC W FL29ite 110 200 Inkster Rood LU M Su El DOR BEYOND. lit- I T_ Southfield.'Ml 48034 USA I LU 248 355 0890 LU 248 355 0895 Fox LL 1� I '- -1 _j ❑ Cw,4qh6 Q 2000 JGA. h,. LLJm cn All '19hi. www.jgo.com ry JGA'Prj #: 1 209-057 2 K T� 5 INTERIOR ELEVATION 4 INTERIOR ELEVATION SCALE: 1140 V-0' sheet file SCALE: 1/4" = 11-00 sheet file - SCALE: IIA' = I' -W sheet file K S. 3i. SCALE: 114' = V-0' sheet file /" 8 "'�, INTERIOR ELEVATION A-1.1 _ -1 :,),1 SCALE: I/A' = V-0" 5leet, file 5r -At -E. IIA" - 1'-0' sheet file LW. INTERIOR ELLEVATION 5r -ALE- IIA' = 1'-0' sheet File 2W24"23/4 Prj. no. Drawn 71t 1A 2 Checked ALS Approved KN LU scale this print. Use figured 71, 1, F V A 1'! 0 lkl L= LQ IU LW. INTERIOR ELLEVATION 5r -ALE- IIA' = 1'-0' sheet File 8-209-012 Prj. no. Drawn RC, TW Checked ALS Approved KN LU scale this print. Use figured dimensions only. 1, F V A 1'! 0 LQ IU Z: X < < au .2 U_ S' _j U < 0- C14 DRAWINGS ISSUED FOR. 0 programming IN schematic des. 02.0q.Oq • design dev. • bidding • permits 03.16.Oq • construction IN landlord prelim. 02.0q.Oq IM landlord final 02.27.Oq REVISIONS: 8-209-012 Prj. no. Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. 1, F V A 1'! 0 o - LL T r� n 4 LL LL C ry LL LL [Y a -- w T V SCALE: 1/4" = I'-0" SCALE: 1/4" = I'-0" W M LLLL N Q LU LU s N O LU LL INTERIOR LTI N sheet file SCALE: 1/4" = l'-0" sheet file ,o LU s O �i �t r -- w LU C) LU LL w I sheet file �—�'j --- ------ I/8' %J � EY El— � � m dJ i v :�:__ V6 sheet file SCALE: 1/4" = l'-0" sheet file ,o LU s O �i �t r -- w LU C) LU LL w I sheet file INTERIOR ELEVATION SCALE: I/4" = 1'-0' LL.I a= 0 LL �i t w O LU LL sheet File INTERIOR A 1 ION SCALE: 194' = 1'-0" 5i eet file L! SCALE: 1/4" = 1'-0" GI SCALE: 1/4" = I'-0' 131 sheet file OPEN TO SALES FLOOR BEYOND. ---- sheet file ELEVATION KEY NOTES 1 NEW STOREFRONT ENTRY AND GLAZING 5Y5TEM. REFER TO SHEETS A-0:2, A-4.1, AND A-4.2 FOR MORE INFORMATION. [2 ] STOREFRONT SIGN. REFER TO SHEETS A-4.1 AND A-42 FOR MORE INFORMATION. aWALL BASE. REFER TO SHEET A -lb FOR MORE INFORMATION. 4 LINE OF NEW GYP. BD. CEILING REFER TO 5HEET5 A-2.1, A-2.2, A-23, A-2.4, AND A-2.5 FOR MORE INFORMATION. 5 GYP. BD. WALL. REFER TO SHEETS A-I.I, A-1.2, A-13, A-1.4, A-15, A-I.b, AND A-5.1 FOR FINISHES AND MORE INFORMATION. NEH WARDROBE FIXTURE. REFER TO 5HEET5 F-1.1, F-1.2, F-13, F-1.4, F-15, A-1.1, A-12, A-13, A-1.4, AND A-1.5 FOR MORE INFORMATION. G.G. TO LEAVE I/8" GAP BETWEEN WALL AND FIXTURE. SURFACE MOUNTED STANDARDS H/ POP -OUT CONDITION. REFER TO 5HEET5 F-12 AND A-5.5 FOR MORE INFORMATION. aNEW FRAMES WALL FIXTURE. REFER TO 5HEET5 F-I.I, F-12, F-13, F-1.4, F -I5, A -LI, A-1.2, A-13, A-1.4, A-15, A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION. 91DASHED LINE INDIGATE5 APPROXIMATE LOCATION OF GA5HHRAP. REFER TO PLANS AND SHEET F-1.1 FOR EXACT LOCATION AND MORE INFORMATION. EO HALL PAINT TO EXTEND TO THI5 LINE BEHIND FIXTURE HALL PANELS ONLY (TYP). E LINE OF HEADER. REFER TO SHEETS A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. 12 WALL FIXTURE. G.G. TO PROVIDE F.R.T. BL OGKING IN WALL. REFER TO SHEET F-l.l FOR MORE INFORMATION. F13 COLUMN BUILD OUT. REFER TO 5HEET5 F-I.I, A-I.I, A-12, A-13, A-1.4, A-1.5, AND �-5.1 FOR MORE INFORMATION. 14 STOREFRONT DISPLAY PLATFORM. REFER TO SHEETS A-4.1 AND A-4.2 FOR MORE INFORMATION. 15 FLOATING CEILING SHOWN IN BAGKGROUND/FOREGROUI rte. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. I� FLOOR TO GEILN16 FIXTURE. G.G. TO PROVIDE F.R.T. PLYWOOD BLOGKING IN ADIAGENT CEILING. REFER, TO 5HEET5 F-I.I, F-1.2, F-13, F-1.4, F-15, A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. --- ------ I/8' %J El— 6 i v :�:__ V6 OPEN TO 5ALE5 FLOOR BEYOND.--_,, V i� l INTERIOR ELEVATION SCALE: I/4" = 1'-0' LL.I a= 0 LL �i t w O LU LL sheet File INTERIOR A 1 ION SCALE: 194' = 1'-0" 5i eet file L! SCALE: 1/4" = 1'-0" GI SCALE: 1/4" = I'-0' 131 sheet file OPEN TO SALES FLOOR BEYOND. ---- sheet file ELEVATION KEY NOTES 1 NEW STOREFRONT ENTRY AND GLAZING 5Y5TEM. REFER TO SHEETS A-0:2, A-4.1, AND A-4.2 FOR MORE INFORMATION. [2 ] STOREFRONT SIGN. REFER TO SHEETS A-4.1 AND A-42 FOR MORE INFORMATION. aWALL BASE. REFER TO SHEET A -lb FOR MORE INFORMATION. 4 LINE OF NEW GYP. BD. CEILING REFER TO 5HEET5 A-2.1, A-2.2, A-23, A-2.4, AND A-2.5 FOR MORE INFORMATION. 5 GYP. BD. WALL. REFER TO SHEETS A-I.I, A-1.2, A-13, A-1.4, A-15, A-I.b, AND A-5.1 FOR FINISHES AND MORE INFORMATION. NEH WARDROBE FIXTURE. REFER TO 5HEET5 F-1.1, F-1.2, F-13, F-1.4, F-15, A-1.1, A-12, A-13, A-1.4, AND A-1.5 FOR MORE INFORMATION. G.G. TO LEAVE I/8" GAP BETWEEN WALL AND FIXTURE. SURFACE MOUNTED STANDARDS H/ POP -OUT CONDITION. REFER TO 5HEET5 F-12 AND A-5.5 FOR MORE INFORMATION. aNEW FRAMES WALL FIXTURE. REFER TO 5HEET5 F-I.I, F-12, F-13, F-1.4, F -I5, A -LI, A-1.2, A-13, A-1.4, A-15, A-2.1, A-2.2, AND A-23 FOR MORE INFORMATION. 91DASHED LINE INDIGATE5 APPROXIMATE LOCATION OF GA5HHRAP. REFER TO PLANS AND SHEET F-1.1 FOR EXACT LOCATION AND MORE INFORMATION. EO HALL PAINT TO EXTEND TO THI5 LINE BEHIND FIXTURE HALL PANELS ONLY (TYP). E LINE OF HEADER. REFER TO SHEETS A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. 12 WALL FIXTURE. G.G. TO PROVIDE F.R.T. BL OGKING IN WALL. REFER TO SHEET F-l.l FOR MORE INFORMATION. F13 COLUMN BUILD OUT. REFER TO 5HEET5 F-I.I, A-I.I, A-12, A-13, A-1.4, A-1.5, AND �-5.1 FOR MORE INFORMATION. 14 STOREFRONT DISPLAY PLATFORM. REFER TO SHEETS A-4.1 AND A-4.2 FOR MORE INFORMATION. 15 FLOATING CEILING SHOWN IN BAGKGROUND/FOREGROUI rte. REFER TO 5HEET5 A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. I� FLOOR TO GEILN16 FIXTURE. G.G. TO PROVIDE F.R.T. PLYWOOD BLOGKING IN ADIAGENT CEILING. REFER, TO 5HEET5 F-I.I, F-1.2, F-13, F-1.4, F-15, A-2.1, A-2.2, A-23, AND A-2.4 FOR MORE INFORMATION. 7T�\'1NTErK-d'.0R_ELEVAT10N, "5( --ALE- 114" = i' - sheet file o-' 3 131 �I P, Consultants: RETAIL DESIGN CONSULTANT JCA, Iliac 29110 Inkster Road Suite 200 Southfield, MI 48034 USA . 1 248 355 0890 248 355 0895 Fox Capy.Nht 0 2009 JCA. In< . Nt 14hta --d www. jga.corn JGA Pr j , 1-209--057 DRAWINGS ISSUEDFOR: 0 programming 10 schematic des. 02.0q.Oq 0 design dev. 0 bidding N permits 03.I6.Oq 0 construction P landlord prelim. 02.0q.Oq 11 landlord final 0227.Oq REVISIONS: Drawn RG, TW Checked ALS Approved KN Do not scale this print: Use figured dimensions only. Drawing title: Sheet np. i� ,; El— i v :�:__ V6 V i� 7T�\'1NTErK-d'.0R_ELEVAT10N, "5( --ALE- 114" = i' - sheet file o-' 3 131 �I P, Consultants: RETAIL DESIGN CONSULTANT JCA, Iliac 29110 Inkster Road Suite 200 Southfield, MI 48034 USA . 1 248 355 0890 248 355 0895 Fox Capy.Nht 0 2009 JCA. In< . Nt 14hta --d www. jga.corn JGA Pr j , 1-209--057 DRAWINGS ISSUEDFOR: 0 programming 10 schematic des. 02.0q.Oq 0 design dev. 0 bidding N permits 03.I6.Oq 0 construction P landlord prelim. 02.0q.Oq 11 landlord final 0227.Oq REVISIONS: Drawn RG, TW Checked ALS Approved KN Do not scale this print: Use figured dimensions only. Drawing title: Sheet np. i� ,; SCALE: 3/16° = 1'-0" %57bme MALL BULKHEAD ABOVE. 13/4' x 4 1/2' 5TOREFRONT GLAZING 516N TRANSFORMER BOX WITH 015GONNEGT. IS 6A6E BOX BEAM HEADER 516N 5UPPORT. METAL FRAMING FOR GEILIN6 fF -.�� AGCE55 PANEL. I? HOLE FOR ELECTRICAL FEED. TWO REQUIRED AT BRA( KET5. '�--2x F.R.T. NAILER TO 5E6URE 516NIN6. LU t y 2x2 TUBE STEEL MOUNTIN6 BRACKET WITH 2x F.R.T. NAILER TO 5EGURE 516NIN6. BRACKET PROVIDED BY 516N G 4° ONTRAGTOR. BRAGKET5 TO BE POWDER COATED TO MATCH 516N GAN. r 4 ' 1-1/2°x1-1/2' INSERTION TUBE 5TEEL MOUNTING _ BRACKET (AND INTE6RAL 5TRU( TURE OF 516N SUPPORT) WITH PRE DRILLED 5EGURIN6 PLACEMENT. MOUNTING BRAGKET5, HARDWARE, ETC. AND ALL RETURNS TO BE PRE -FINISHED TO MATCH BRUSHED ALUMINUM. TOP BRACKET PLATE. HEX BOLT CONNECTION WITH TRU55 HEAD GARRIA&E TYPE HEAD ON MALL 51DE. 1 �Ij, A J.bP06194 aZJ. KET. L.1st.t >26IlN+ .hLA-..a. a1a.V.. aAcu'+-at Tr.T3�w wr.TiiM� } i1111i liq SCALE: 1 1/2" = V-0" -3/16' AGRYLIG 516N FACE 5GREWED TO 516N GAN. #211-1 % RED AGRYLIG. -FIN15H INTERIOR OF 516N WHITE E�rA?�IEL. R; i LED LlCrtr' M&BY 516N CONTRA( TOR. -3/4' METAL GLAD 516N BACKED' HITH DITERI.OR NEON APPLIED. NOTE.- 516N OTE:516N CONTRACTOR TO PROVIDE TO CLIENT, ARCHITECT, AND LANDLORD 516N 5HOP DRAI^IINC-S FOR APPROVAL PRIOR TO 516N FABRICATION. —f h 'I 1/L J 1 VI�L_I hVll 1 IJL.rALII'11J BASE TO BE KAWNEER TRIFAB V6 450 OR EQUA►_ BRUSHED 5TAINLE% FIN15H, OR APPROVED EQUAL. 4 A-4.1 CENTERLINE OF 516N LOGO 15 GENTERLINE OF ENTRY OPENIN6. 0 SCALE: 1 1/2° = I'-0" ELEVATION ---EXI5TIN6 LANDLORD AWNING ABOVE. `- -- 2" TUBE STEEL 5TR.UGTURAL 5U5PEN51ON 'GUIDE 5ECURED TO BOX BEAM ABOVE. 516N SUSPENSION TO MATCH 516N GAN FIN15H. ACRYLIC FADED INTERNALLY ILLUMINATED 5TOREFRONT 51GNA6E. META- CAN LETTER5 WITH REMOTE TRAN5FORMER. 1/2' HORIZONTAL 5UPPORT 516N 5U5PEN510N TO MATCH 516N GAN FIN15H. FASTENED INTERNALLY PRIOR TO FACE ATTACHMENT. T(N,q NOTE: 51ON CONTRACTOR TO PROVIDE TO CLIENT. ARCHITECT AND LANDLORD 516N '5RGP VRAWti 66'F0R--AFI`'L0VAL "PM0R TO 516N FABRICATION. ALL 516N5 MU5T BE SUBMITTED 5EPARATELY WITH FULL DETAIL5 AS TO MANUFACTURE AND ATTACHMENT. SIGN MIr5T BE 505PENDED FROM TF_NANT 5 5TRU6TURE Q NOT LANDLORDS BULKHEAD. sn-det Southfield, MI 4dU54 U5A 248 355 0890 248 355 0895 Fox Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: Cpl h—mss �1 IM r A �n ARS a 0 " REVISIONS: Prj. no. B—20q Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED STOREFRONT FLAN AND ELEVATION DRAWINGS ISSUED FOR: 0 programming N schematic des. tu d design dev. O bidding IN permits 03.16.Oq 0 construction lu II 02.0q.0q landlord final 02.27.Oq tu a,3 M tuC LU o � o © REVISIONS: Prj. no. B—20q Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED STOREFRONT FLAN AND ELEVATION DRAWINGS ISSUED FOR: 0 programming N schematic des. 02.0q.0q d design dev. O bidding IN permits 03.16.Oq 0 construction landlord prelim. 02.0q.0q landlord final 02.27.Oq REVISIONS: Prj. no. B—20q Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED STOREFRONT FLAN AND ELEVATION SCALE: 1 1/2° = 1'-0' w5-strfrtt — E:r'IL)LD VU:; FLOOR .BOX Y41TH SRUSI-ED MINUM COVER Sg5T5PAL. REFER TO NOTE 7N SHEET A-1.1 FOR MORE INFORMATION. -BACK FIRST LAYER OF F.R.T. MDF BOARD ALI-0r4 CLEARFNGE FOR FLOOR BOX_ 5H FLOOR REFER TO 5HEET 6 FOR MORE INFORMATION. "E55M L16HT TRACK IN ?" SURFACE MOUNTED ANNA.. CLADDED IN JEEL TO BE KAHNEER 450' OR APPROVED EQUAL, > F.R.T. NAILER BY 6.6. LYHOOD SACKER InIrTH I BOARD CEILING. 4' SQUARE 5TAINLE55 i SEGURED TO 6LA55 5 POINTS VERTICALLY. )NTRAGTOR TO ,LIPS FOR 1/2" 6LA55. FIXTURE. REFER TO SHEETS -1.3, F-1.4, F-15, A-I.I, AND ORE INFORMATION. 7O1_1514ED TEMPERED H" CLEAR 51LIGO4E, AT ALL. MAXII-IIJMUM51ZE MITT 4'. 'AGE 'ER5 112' F.R.T. MDF OVER STUD FRAMING. MDF TO BE ND GLUED TO FRAMING 5 ARE TO BE LAR TO EACH OTHER. ALL TO BE FILLED HITH AUTO ,0 FILLER AND SHALL BE 90TH TO ELIMINATE VISUAL -MATERIAL. FIN15H N A HIGH 6L055 PAINT. 1510 BE 'INDEPElII eff OF MO REt WAB.E. R. VRFAGE MWITED 6LAZI% ADDED IN STAINLESS 5TEEEL IEER 'TRIFAB VG 450' OR EQUAL. SECURED TO :LOOK BY G.G. ' "'209-012 RECESSED FLOOR WX SECTIONAT STOREFRONT ENTRY ALS SCALE: 3° = 1'-0° ws-pltfrm- j# A-4.1 aCALE: 1 1120 = 11_p° ups-strfnt ENTRY ,NTRAGTOR TION ON . OF MER6ENGY IOR OF ,ILLE. AM ER TO iUM LY 4T 516N )PPORT V,TION. 1ITH RIALS. )R TO EFER X41 4. ENTRY SHITGH Z AND )NT. :LEA5E R RE .0 DRAWINGS ISSUED FOR: ❑ programming 19 schematic des. 02.Oq.0q ❑ design dev. ❑ bidding N permits 03.16.0rl ❑ construction 19 landlord prelim. 02.0q•0q 0 landlord final 02.27.0q REVISIONS: Prj. no. "'209-012 Drawn RC, TH Checked ALS Approved KN Do not scale this print. Use IU V Drawing title: STOREFRONT 1 LU Q au W 41 m LU lu C� o —AUA J .� x 0 10 �J � C �-- t�� DRAWINGS ISSUED FOR: ❑ programming 19 schematic des. 02.Oq.0q ❑ design dev. ❑ bidding N permits 03.16.0rl ❑ construction 19 landlord prelim. 02.0q•0q 0 landlord final 02.27.0q REVISIONS: Prj. no. "'209-012 Drawn RC, TH Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: STOREFRONT SECTIONS Sheet no. 1 518" METAL 5TUD5 ON EXP©5ED 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/b' 6YP_ W. TO ADJACENT CEILING. TAPE AND 5AND AS REQUIRED TO ACCEPT FINISH. ONE (I) LAYER OF 5/8° GYP. BD. TO ADJACENT II GEILIN6. ON EXPOSED SIDES OF 5TUD5 ONLY. I I WALL BASE. REFER TO SHEET A -Ib FOR MORE INFORMATION_ TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX_ OF 2'-O' O.G. IFLEXIBLE 5EALANT. i �-- FINISH FLOOR. REFER TO SHEET A -lb FOR MORE INFORMATIOK CONCRETE FLOOR 51_AB A55EMBLY. NOTE: WALL TYPE "T' ws-5nd -atten uyU 1 /, U FU L WHALL TYPE 'v' A-1.5 A 4-1.4 A A -i_1 SCALE: 307 1'-00 - - LLs-IS&5t b' MIrTAL 5TUP5 WITH ONE (1) LAYER OF 112" GEMENT BOARD TO 4'-q' A.F.F. AND ONE (1) LAYER OF 112" 6REENB0ARD FROM 4'-q° AF:F. TO 3' ABOVE ADJACENT CEILING ON EXPOSED SIDES OF 5TU5. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. ONE (I) LAYER OF lit' GREENBOARD FROM 4'-q' AFF. TO 3" ABOVE ADJACENT CEILING ON EXPOSE-➢ 51DE5 OF 5TUD5 ONLY. ONE (U LAYER OF I/2' GEMENT BOARD TO 4'-q' A.F.F. ON EXP05ED 51DE5 OF 5TUD5 ONLY. ALIGN 5TUD KNOCKOUTS (TYP). WALL. BA5-F. REFER TO 5HEET A -1b FOR MORE INFORMATION. FLEXIDLE SEALANT, FINISH FLOOR. REFER, TO SHEET A -Ib FOR MORE INFORMATIat TRACK AT FLOOR ANp BOTTOM OF STRUCTURE ANCHORED AT A MAX, OF 2'-0' O.G. G hY_RE`ff: F1 Ge R -Q AR Acf-D O Y. NCN 1, LL Nkpa OTE: `TYPE V' A-1.5 A A-1.4 A-1.1 SCALE: 3" = 1W - w545t-Lltrm --- b° 1-1ETAL 5TUP5 PLUMBING WALL GDAr5,TRL'CTION_ ON'EXP05EP SIPES OF 5TLD555 ONE (1) LAYER OF I I 5/8' OYP. BD. TO ADJACENT CEILING. TAPE AND 5AAID A5 REGIARED TO ACCEPT FIM58. i AL10AI 5TU9 KNPGKOUT5 (Ti?). I I1ALL BA5E. REFER TO 511ER M(�,r rT A -Ib FO IATORMATION. II FLEXIBLE SEALANT. i FTi 1 irL 'ti REF.EP TJ _%EF A -lb FOR 'i w 1NFl.ARP4ATlDAL TISK AT FLOOR AtV B9TT0M OF 5Ta'I ALARA ,1 M+DRED AT A :MAS. OF 7-0� OL. GGW> RETE FLOOR SIS A55D-0-Y. � k°o W WIN U I LUI LNG WALL W/ GYP, . rE' TYPE' A-1.5 A-1.4 A -1A j SCALE: 3' = P-0"- 3 5/8' METAL 5TUP5 k,11TH ONE (1) LAYER OF 5/8' GYP. BD. GEMENT BOARD TO 4'-q' A.F.F. AND ONE (1) LAYER OF ` - ROOM ON BOTH 51DE5 OF STUDS. 5TUD CAVITY TO BE FILLED FULL EXPOSED 51DE5 OF STUDS OVER ONE (1) LAYER OF 1/2" F.R.T. CORRIDOR 3 5/5" METAL 5TUD5 WITH ONE (1) LAYER OF 518' GYP. DO, ON HEIGHT WITH FIBERGLA55 SOUND REDUCING BATT INSULATION. 51DE�F SIDE OF WARDROBE FIXTURE/5ALE5 FLOOR 51DE OF 5TUD5 OVER SIDE �Le,TOBE TAPE AND SAND A5 REQUIRED TO AGGEPT FINISH. s t 1 i BD. FILL FROM B -O" A_F.F. TO ADJACENT CEILING. ON BACK OF FULL Hr15HT SOUND REDUCING FIBERGLASS 5ALE-5 COBE FIXTURE/f ITTING ROOM 51PE OF STUDS ONE (1) LAYER IONE FLOOR BATT IN5U1_ATION IN 5TUD GAVITIE5. (I) LAYER OF 1/2' CEtfiENT BOARD TO �I'_�i, WARDROBE SIDE TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. L l ADJACENT CEILING ON EXP05ED 51DES OF STUDS. ONE (I) LAYER OF 51b' 6YP. BD. ON BOTH SIDES OF STUDS ONLY. FINI5H FLOOR. REFER TO SHEET A.F.F. ON POT'rl 51DF-5 OF STUDS ONLY. I � � II -' AL16N STUD KNOCKOUTS (TYP). A-I.b FOR MORE INFORMATION 51DE 4 ALi6N STUD KNG_KOUT5 (TYP). A.F•F. ON WO_cED 517E-5 OF 5TUD5. I WALL BA5E. REFER TO SHAT A -Ib FOR MORE WALL BASE. REFER TO SHEET A -lb ALI{N 5TUD KNOGKOUT5 (TYP). WALL BA5E. REFER TO SHEET A -lb FOR �► FINISH FLOOR. REFER.TO SHEET A -lb FOR I INFORK4740K 'MORE INFORMATION. MORE IAIFM4ATION. IWALL FLEX113LE SEALANT. BA5E. REFER T.U.5HEET A-I.b FOR MORE ONE (1) LAYER OF 5/8" GYP. BD. ON EXPOSED SIDES OF STUDS. o TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE INFORMATLON. FLEXIBLE SEALANT. I r FLEXIBLE 5EALAWNT WALL TYPE 'D" FOR MORE INFORMATION. �'U / "P.� I ANCHORED AT A MAX. OF 2'-0" O.G. FINIS!, L FLOOR. 17FFER TO SHEET A-1.6 FOR / I f ANCHORED AT A MAX OF 2'-0' O.G. IFINISH CONCRETE FLOOR SLAB. A55EMBLY. NOTE: FLEXIBLE 5EALANT. / TRALK AT FLOOR AND BOTTOM OF STRXTl ANCHORED AT A MAX. 11 OF 2'-0' D.G. '`'�--- GOW-RETE FLOOR SLAB A55EMB1_Y. X X X''1 I NU FIN15H FLOOR. REFER TO SHEET A-1.6 FOR MORE A-1.5 A A-•1.4 AA -i_1 SCALE: 3' = I'-0' ws-titan - ADJACENT CEILING. TAPE AND 5ANO A5 REOUIRED TO ACCEPT FINISH. WALL 13A5E. REFER TO SHEET A -Ib FOR MORE INFORMATION. INFORMATION. l 1 4 4 a . CONCRETE FLOOR SLAB A55EMBLY. T iSOUND ATTr.NUATED WALL A-1.5 A-1.4 A A-1.1 SCALE: 3" = I'-0" 1 518" METAL 5TUD5 ON EXP©5ED 51DE5 OF 5TUD5 ONE (1) LAYER OF 5/b' 6YP_ W. TO ADJACENT CEILING. TAPE AND 5AND AS REQUIRED TO ACCEPT FINISH. ONE (I) LAYER OF 5/8° GYP. BD. TO ADJACENT II GEILIN6. ON EXPOSED SIDES OF 5TUD5 ONLY. I I WALL BASE. REFER TO SHEET A -Ib FOR MORE INFORMATION_ TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX_ OF 2'-O' O.G. IFLEXIBLE 5EALANT. i �-- FINISH FLOOR. REFER TO SHEET A -lb FOR MORE INFORMATIOK CONCRETE FLOOR 51_AB A55EMBLY. NOTE: WALL TYPE "T' ws-5nd -atten uyU 1 /, U FU L WHALL TYPE 'v' A-1.5 A 4-1.4 A A -i_1 SCALE: 307 1'-00 - - LLs-IS&5t b' MIrTAL 5TUP5 WITH ONE (1) LAYER OF 112" GEMENT BOARD TO 4'-q' A.F.F. AND ONE (1) LAYER OF 112" 6REENB0ARD FROM 4'-q° AF:F. TO 3' ABOVE ADJACENT CEILING ON EXPOSED SIDES OF 5TU5. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. ONE (I) LAYER OF lit' GREENBOARD FROM 4'-q' AFF. TO 3" ABOVE ADJACENT CEILING ON EXPOSE-➢ 51DE5 OF 5TUD5 ONLY. ONE (U LAYER OF I/2' GEMENT BOARD TO 4'-q' A.F.F. ON EXP05ED 51DE5 OF 5TUD5 ONLY. ALIGN 5TUD KNOCKOUTS (TYP). WALL. BA5-F. REFER TO 5HEET A -1b FOR MORE INFORMATION. FLEXIDLE SEALANT, FINISH FLOOR. REFER, TO SHEET A -Ib FOR MORE INFORMATIat TRACK AT FLOOR ANp BOTTOM OF STRUCTURE ANCHORED AT A MAX, OF 2'-0' O.G. G hY_RE`ff: F1 Ge R -Q AR Acf-D O Y. NCN 1, LL Nkpa OTE: `TYPE V' A-1.5 A A-1.4 A-1.1 SCALE: 3" = 1W - w545t-Lltrm --- b° 1-1ETAL 5TUP5 PLUMBING WALL GDAr5,TRL'CTION_ ON'EXP05EP SIPES OF 5TLD555 ONE (1) LAYER OF I I 5/8' OYP. BD. TO ADJACENT CEILING. TAPE AND 5AAID A5 REGIARED TO ACCEPT FIM58. i AL10AI 5TU9 KNPGKOUT5 (Ti?). I I1ALL BA5E. REFER TO 511ER M(�,r rT A -Ib FO IATORMATION. II FLEXIBLE SEALANT. i FTi 1 irL 'ti REF.EP TJ _%EF A -lb FOR 'i w 1NFl.ARP4ATlDAL TISK AT FLOOR AtV B9TT0M OF 5Ta'I ALARA ,1 M+DRED AT A :MAS. OF 7-0� OL. GGW> RETE FLOOR SIS A55D-0-Y. � k°o W WIN U I LUI LNG WALL W/ GYP, . rE' TYPE' A-1.5 A-1.4 A -1A j SCALE: 3' = P-0"- TWO (2) LAYER OF 518' TYPE 'X' FIREGODE 6YP, BD. FIRE TAPED A?V 5EALED TO THE UNDERSIDE OF THE 5TRUGTURF ABOVE, BOTH 51DE5. 3RIDGIN6. ALIGN STUD KNOGKOUT5. ^IAL L BASE. REFER TO SFEET A -lb FOR AORE INFORMATION. 9N15H FLOOR MATERIAL. REFER TO SHEET A -I.6 FOR MORE INFORMATION. LEXIBLE SEALANT. �ONGRETE FLOOR ASSEMBLY. MOTE: Y _ Y � i' F / I NC14 STUD LL WALL TYPE °Y' A-1.5 AA-1.4AA-1-1 SCALE: 3' = 1'-0' ua-Dy 3 5/1)' t-LTAL 5TIV5 WITH ONE (1) LAYER OF 1/2' GEMENT BOARD TO 4'-q' A.F.F. AND ONE (1) LAYER OF ` 112' C-RFENBOARD FROM 4'-q' A.F.F. TO 3' ABOVE ROOM ADJACENT GELLING ON .PATH 51DE5 OF 5TIE6. TAPE EXPOSED 51DE5 OF STUDS OVER ONE (1) LAYER OF 1/2" F.R.T. CORRIDOR 3 5/5" METAL 5TUD5 WITH ONE (1) LAYER OF 518' GYP. DO, ON AND 5AA19 AS REGVIRfD TO ACCEPT FIN15H. 51DE�F SIDE OF WARDROBE FIXTURE/5ALE5 FLOOR 51DE OF 5TUD5 OVER SIDE �Le,TOBE 01F }/2° >SRFAR17 FRIJM'-�i' A 1= F. T�7 3' s t 1 i BD. FILL FROM B -O" A_F.F. TO ADJACENT CEILING. ON BACK OF ABOVE AD•JAGEAIY GEILM ON BOTH FIDE OF 5EV5 OW(- 5ALE-5 COBE FIXTURE/f ITTING ROOM 51PE OF STUDS ONE (1) LAYER IONE FLOOR OF 51#3' GYP. BD. OVER METAL 5TUD5 TO ADJACENT CEILING. (I) LAYER OF 1/2' CEtfiENT BOARD TO �I'_�i, WARDROBE SIDE TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. L FIXTURE ADJACENT CEILING ON EXP05ED 51DES OF STUDS. ONE (I) LAYER OF 5/8" GYP. BD. FINI5H FLOOR. REFER TO SHEET A.F.F. ON POT'rl 51DF-5 OF STUDS ONLY. I � � II -' ONE (1) LAYER OF 1/2' FRT. PL1 WOOD TO 8'-0" A-I.b FOR MORE INFORMATION 51DE 4 ALi6N STUD KNG_KOUT5 (TYP). A.F•F. ON WO_cED 517E-5 OF 5TUD5. I WALL BASE. REFER TO SHEET A -lb ALI{N 5TUD KNOGKOUT5 (TYP). WALL BA5E. REFER TO SHEET A -lb FOR �► FINISH FLOOR. REFER.TO SHEET A -lb FOR I =� 'MORE INFORMATION. MORE IAIFM4ATION. IWALL FLEX113LE SEALANT. BA5E. REFER T.U.5HEET A-I.b FOR MORE ONE (1) LAYER OF 5/8" GYP. BD. ON EXPOSED SIDES OF STUDS. o -WALL BA5E. REFER TO SHEET A-I.b INFORMATLON. FLEXIBLE SEALANT. I r FLEXIBLE 5EALAWNT WALL TYPE 'D" FOR MORE INFORMATION. �'U / "P.� I -'_ FINIS!, L FLOOR. 17FFER TO SHEET A-1.6 FOR / I f ANCHORED AT A MAX OF 2'-0' O.G. IFINISH CONCRETE FLOOR SLAB. A55EMBLY. NOTE: t-IOR.F_ INFORMATION. / TRALK AT FLOOR AND BOTTOM OF STRXTl ANCHORED AT A MAX. 11 OF 2'-0' D.G. '`'�--- GOW-RETE FLOOR SLAB A55EMB1_Y. X X X''1 I NU ""1LET I� Iii LL WALL TYPE °X, A-1.5 A A-•1.4 AA -i_1 SCALE: 3' = I'-0' ws-titan - TWO (2) LAYER OF 518' TYPE 'X' FIREGODE 6YP, BD. FIRE TAPED A?V 5EALED TO THE UNDERSIDE OF THE 5TRUGTURF ABOVE, BOTH 51DE5. 3RIDGIN6. ALIGN STUD KNOGKOUT5. ^IAL L BASE. REFER TO SFEET A -lb FOR AORE INFORMATION. 9N15H FLOOR MATERIAL. REFER TO SHEET A -I.6 FOR MORE INFORMATION. LEXIBLE SEALANT. �ONGRETE FLOOR ASSEMBLY. MOTE: Y _ Y � i' F / I NC14 STUD LL WALL TYPE °Y' A-1.5 AA-1.4AA-1-1 SCALE: 3' = 1'-0' ua-Dy 2 1/2" METAL STUDS WITH ONE (1) LAYER 1/4° GYP. BD. OVER ONE (1) CONTINUOUS LAYER OF 1/2" F.R.T. PLYWOOD BLOGKIN6 ON BOTH SIDES OF STUDS. I. BRIDGING. O ALI6N STUD KNOCKOUTS. I WALL BA5E. REFER TO SHEET A-1.6 FOR MORE INFORMATION. 'FIN15H FLOOR MATERIAL. REFER TO SHEET A- Lb FOR MORE INFORMATION. I l I TRACK 5EGURED TO FLOOR_ All Qn 9 /I, N N N FI:TTING ROOM PARTITIONNOTE: WALL TYPE "N" A-1.5 A-1.4 A-1.1 SCALE: 3" = 1'-0" ws-2125t-cap 2 112' METAL 5TU05 WITH ONE (1) LAYER 518" GYP. BD, ON 130TH 51DE5 AND GYP. BD. GAP AT TOP. TAPE, SPACKLE d SAND A5 REQUIRED TO ACCEPT FINISH. L ITALIGAI 5TUD KNOCKOUTS (TYP). , - T__ , WALL BA5E. REFER TO SHEET A -I.6 FOR MORE d INFORMATION. O FINISH FLOOR. REFER TO SHEET A -I.6 FOR MORE INFORMATION. i FLEXIBLE SEALANT. TRAGK AT FLOOR AND BOTTOM OF STRUCTURE ANCHORED AT A MAX. OF 2'-0' O.G. CONCRETE FLOOR SLAB ASSEMBLY. 0 o FITTING WALLS NOTE: WALL `TYPE 'O" EA- . 5 , A-1.4 A-1.1 SCALE: 3' = 1'-0' w5-212st-gGhgt 1 S!b' IETAL.51)D5 ON EXPOSED 5112E5 DF .ONE.(1) LAYER OF U2" FF -T. PLYWOOD TO ADJACENT GEILING WITH ONE (1) LAYER OF 5/8' 6YP. BO. OVER PLYWOOD TO ADJACENT GEILIN6. TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. I ( ONE (1) LAYER OF 518' .6YP. BD_ ON 112' FR.T. PLYWOOD. I ON EXP05ED .SIDES OF STIP ONLY. I :1 -kIALL BASE. REFER TO ET.A-1.6 FOP 'MORE 1NFM-1ATI01•t. TRACK AT FLOOR AND BOTTOM OF STRUCTURE I I ANCHORED AT A MAX. OF 2'-0' O.G. FLEXIBLE SEALANT. FIN15H FLOOR. REFER TO SHEET A -ib FOR Vll�k-;;�;�MORE INFORMATION. CONCRETE FLOOR SLAB A55EMBLY. NOTE: WALL TYPE 'P" I /H STUD FU -OUT WALL W/ LYW I i'-0' w5 -1%5t -ply 15/8' WTAL 5-R)95 ON EXXF05E0 .510E5 OF 5TLV5 GIE 0) .LAYER 'OF 5/b' TYPE ')(I li 6YP. IA. TO DECK ALIVE. TAPE Alm SAND A5 RFCUIRED TO ACCEPT FINat ow (11 LAYER OF 5/1)2 TYPE °X° 6YF. W TO DEfA ABOVE ON EW05ED 51DE15 OF 5TUD5 <LY. I Ij TRACK AT FLOOR AND BOTTOM OF STRUCTURE ANCHORED AT A MAX. OF 2'-0' O.G. i I I WALL BASE. REFER TO SHEET A -lb FOR MORE INFORMATION. FLEXIBLE SEALANT. FIN15H FLOOR. REFER TO SHEET A -Lb FOR MORE INFORMATION. GONC RETE FLOOR SLAB ASSEMBLY. NOTE: Q I-NOUR RATED 1 5/8" STUD WALL WALL TYPE 'Q' A-1.5 A-1.4 A-1.1 SCALE: 3' = 1'-0' ws-lhr-1585t - FITTIIt6 3 5/8" METAL 5TUD5 WITH ONE (1) LAYER OF 518" GYP. BD. ON ONE (0 -LAYER OF. 6YP. BD: FILL FROM b' -O' A.FF. TO ` ' =----b" METAL STUDS WITH ONE (I) LAYER OF 5A8' ROOM ADJACENT GEILIN6 ON EXP05EP 51DE5 OF STUDS. EXPOSED 51DE5 OF STUDS OVER ONE (1) LAYER OF 1/2" F.R.T. CORRIDOR 3 5/5" METAL 5TUD5 WITH ONE (1) LAYER OF 518' GYP. DO, ON 51DE�F SIDE OF WARDROBE FIXTURE/5ALE5 FLOOR 51DE OF 5TUD5 OVER SIDE �Le,TOBE ONE'(1) LAYER OF 1/2' FR.T. PLYWOOD TO b' -O" AFF• WITH GYP. s t F 1 BD. FILL FROM B -O" A_F.F. TO ADJACENT CEILING. ON BACK OF REQUIRED TO AGGEPT FINISH. 5ALE-5 COBE FIXTURE/f ITTING ROOM 51PE OF STUDS ONE (1) LAYER BACK OF FLOOR OF 51#3' GYP. BD. OVER METAL 5TUD5 TO ADJACENT CEILING. WARDROBE SIDE TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. L FIXTURE ADJACENT CEILING ON EXP05ED 51DES OF STUDS. ONE (I) LAYER OF 5/8" GYP. BD. FINI5H FLOOR. REFER TO SHEET FITTING I � � ROOM -' ONE (1) LAYER OF 1/2' FRT. PL1 WOOD TO 8'-0" A-I.b FOR MORE INFORMATION 51DE 4 A.F.F. ON EXPOSED SIDES OF STUDS. A.F•F. ON WO_cED 517E-5 OF 5TUD5. WALL BASE. REFER TO SHEET A -lb ALI{N 5TUD KNOGKOUT5 (TYP). I FINISH FLOOR. REFER.TO SHEET A -lb FOR ' 1 I =� 'MORE INFORMATION. I 1 ll\ IWALL FLEX113LE SEALANT. BA5E. REFER T.U.5HEET A-I.b FOR MORE ONE (1) LAYER OF 5/8" GYP. BD. ON EXPOSED SIDES OF STUDS. o -WALL BA5E. REFER TO SHEET A-I.b INFORMATLON. _-----------•CONGRETE FLOOR SLAB ASSEMBLY. I r FLEXIBLE 5EALAWNT WALL TYPE 'D" FOR MORE INFORMATION. �'U / "P.� I TRACK AT FLOOR AND 130TTOM OF STRUCTURE w545t / I f ANCHORED AT A MAX OF 2'-0' O.G. IFINISH CONCRETE FLOOR SLAB. A55EMBLY. NOTE: EXPOSED 51DE5 OF 5TUD5 OVER ONE (1) LAYER OF 112' F.R.T. 'A -I 'fOk' 6PE 1NFORMATION. WALL TYPE "M" �1 - M SID A / L FL a/FIN om A-1.5 A-1.4 A-1-1 SCALE: 30 = I'-0" w5-ply-cl6hgt-I51de 2 1/2" METAL STUDS WITH ONE (1) LAYER 1/4° GYP. BD. OVER ONE (1) CONTINUOUS LAYER OF 1/2" F.R.T. PLYWOOD BLOGKIN6 ON BOTH SIDES OF STUDS. I. BRIDGING. O ALI6N STUD KNOCKOUTS. I WALL BA5E. REFER TO SHEET A-1.6 FOR MORE INFORMATION. 'FIN15H FLOOR MATERIAL. REFER TO SHEET A- Lb FOR MORE INFORMATION. I l I TRACK 5EGURED TO FLOOR_ All Qn 9 /I, N N N FI:TTING ROOM PARTITIONNOTE: WALL TYPE "N" A-1.5 A-1.4 A-1.1 SCALE: 3" = 1'-0" ws-2125t-cap 2 112' METAL 5TU05 WITH ONE (1) LAYER 518" GYP. BD, ON 130TH 51DE5 AND GYP. BD. GAP AT TOP. TAPE, SPACKLE d SAND A5 REQUIRED TO ACCEPT FINISH. L ITALIGAI 5TUD KNOCKOUTS (TYP). , - T__ , WALL BA5E. REFER TO SHEET A -I.6 FOR MORE d INFORMATION. O FINISH FLOOR. REFER TO SHEET A -I.6 FOR MORE INFORMATION. i FLEXIBLE SEALANT. TRAGK AT FLOOR AND BOTTOM OF STRUCTURE ANCHORED AT A MAX. OF 2'-0' O.G. CONCRETE FLOOR SLAB ASSEMBLY. 0 o FITTING WALLS NOTE: WALL `TYPE 'O" EA- . 5 , A-1.4 A-1.1 SCALE: 3' = 1'-0' w5-212st-gGhgt 1 S!b' IETAL.51)D5 ON EXPOSED 5112E5 DF .ONE.(1) LAYER OF U2" FF -T. PLYWOOD TO ADJACENT GEILING WITH ONE (1) LAYER OF 5/8' 6YP. BO. OVER PLYWOOD TO ADJACENT GEILIN6. TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. I ( ONE (1) LAYER OF 518' .6YP. BD_ ON 112' FR.T. PLYWOOD. I ON EXP05ED .SIDES OF STIP ONLY. I :1 -kIALL BASE. REFER TO ET.A-1.6 FOP 'MORE 1NFM-1ATI01•t. TRACK AT FLOOR AND BOTTOM OF STRUCTURE I I ANCHORED AT A MAX. OF 2'-0' O.G. FLEXIBLE SEALANT. FIN15H FLOOR. REFER TO SHEET A -ib FOR Vll�k-;;�;�MORE INFORMATION. CONCRETE FLOOR SLAB A55EMBLY. NOTE: WALL TYPE 'P" I /H STUD FU -OUT WALL W/ LYW I i'-0' w5 -1%5t -ply 15/8' WTAL 5-R)95 ON EXXF05E0 .510E5 OF 5TLV5 GIE 0) .LAYER 'OF 5/b' TYPE ')(I li 6YP. IA. TO DECK ALIVE. TAPE Alm SAND A5 RFCUIRED TO ACCEPT FINat ow (11 LAYER OF 5/1)2 TYPE °X° 6YF. W TO DEfA ABOVE ON EW05ED 51DE15 OF 5TUD5 <LY. I Ij TRACK AT FLOOR AND BOTTOM OF STRUCTURE ANCHORED AT A MAX. OF 2'-0' O.G. i I I WALL BASE. REFER TO SHEET A -lb FOR MORE INFORMATION. FLEXIBLE SEALANT. FIN15H FLOOR. REFER TO SHEET A -Lb FOR MORE INFORMATION. GONC RETE FLOOR SLAB ASSEMBLY. NOTE: Q I-NOUR RATED 1 5/8" STUD WALL WALL TYPE 'Q' A-1.5 A-1.4 A-1.1 SCALE: 3' = 1'-0' ws-lhr-1585t - FITTIIt6 3 5/8" METAL 5TUD5 WITH ONE (1) LAYER OF 518" GYP. BD. ON ` ' =----b" METAL STUDS WITH ONE (I) LAYER OF 5A8' ROOM EXPOSED 51DE5 OF STUDS OVER ONE (1) LAYER OF 1/2" F.R.T. CORRIDOR EXISTING ONE (1) LAYER OF 5/8" TYPE_ "X" I i PLYWOOD TO 8'-0' A.F.F. WITH GYP. W. FILL FROM 8'-0" A.F.F. TO SIDE ADJACENT GEILIN6. TAPE AND SAND A5 s t ADJACENT CEILING. TAPE AND 5AND A5 REQUIRED TO ACCEPT FINISH. TO THE UNDERSIDE OF THE 5TRUGTURE ABOVE, REQUIRED TO AGGEPT FINISH. L I I ALIGN STUD KNOCKOUTS (TYP). .(1) LAYER OF 50" TYPE "X" FIREGODE GYP. L ADJACENT CEILING ON EXP05ED 51DES OF STUDS. FINI5H FLOOR. REFER TO SHEET ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-0' I � A-I.b FOR MORE INFORMATION A.F.F. ON EXPOSED SIDES OF STUDS. LC WALL BASE. REFER TO SHEET A -lb G.G. TO PROVIDE SOUND ATTENUATION ALIGN STUD KNOGKOU`T5 (TYP). 1 I I ' 1 I =� INSULATION IN DEMISING WALLS. I 1 ll\ 2 1/2' �`IETAL 5TU05 WITH ONE (1) LAYER 5/8' GYP. BD. OVER ONE (1) :GONTIN 101.6 LAYER OF 1/2' F.R.T. PLYWOOD BLOGKIN6 ON FITTIN6'ROOM"51DE OF 5TUO5. ON FITTING ROOM CORRIDOR 51DE OF STUDS ONE (1) LAYER OF 5/8' GYP. BD. OVER 5TUD5. 6.6. TO APPLY 5/8' GYP. BD. GAP ON WALL. ALIGN STUD KNOCKOUTS. BRIDGING. WALL BASE. REFER TO SHEET A -Lb FOR MORE INFORMATION. FIN15H FLOOR MATERIAL. REFER TO SHEET A -Ib FOR MORE INFORMATION. TRACK 5EGURED TO FLOOR. NOTE: WALL TYPE 'R" ROOM CORRIDOR ALL ws-212st-%6 qt -crap -diff -W 3 518' METAL 5TUQ5. ON TOILET ROOM 51DE OF 5TUD5 ONE (1) LAYER OF U2' GEMENT BOARD TO 4'-q' A.F.F. AND ONE (1) LAYER OF 112' 6REEN30ARD FROM 4'-q' A.F.F. TO 3" ABOVE I I CORRIDOR ADJACENT GEILIN6. ON B.O.H_ CORRIDOR/JANITOR'5 CL05ET TOILET / JANITOR'S 5IDE OF 5TUP5 ONE (1) LAYER OF 51b" GYP. BD. TO ADJACENT SIDE CEILING. TAPE AND 5AND A5 REQUIRED TO ACCEPT FINISH. ROOM I I ALl6N STUD KNOCKOUTS (TYP), I - I WALL BA5E. REFER TO SHEET A -Lb FOR MORE INFORMATION. I I FLEXIBLE SEALANT. FINISH FLOOR. REFER TO 5HEET A -lb FOR MORE I 1 INFORMATION. TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX. OF 2'-O' OL. 'NOTE: CONCRETE FLOOR SLAB A55EMBLY. WALL TYPE "a" / INCH" STUD 170ILET. ® . WALL A--1.5 A-1.4 A A-1.1 j SCALE: 3" - 1'-O' ws-titrm-gyp METAL 5TUD5 ON EXPOSED SIDES OF ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO ADJACENT CEILING WITH ONE (1) I I LAYER OF 5/8' 6YP. BD. OVER PLYWOOD TO ADJACENT CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. II ONE (1) LAYER OF 5/8' GYP. BD. ON 112" F.R.T. PLYWOOD. ON F-XP05ED SIDES OF STUDS ONLY. WALL BASE. REFER TO SHEET A -I.6 FOR MORE INFORMATION. TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX. OF 2'-0' O.G. FLEXIBLE 5EALANT. FIN15H FLOOR. REFER TO SHEET A-I.b FOR MORE INFORMATION. L7 I "IV" /1\ -------CONCRETE FLOOR SLAB A55EMBLY. NOTE: WALL TYPE "6' G G 3 5/8STUD FU K - OUT WALL / LYW A--1.5 A A-1.4 A A-1.1 SCALE: 3' = 1'-0' w5-35S5t_Py 3 5/8' METAL 5TU05 WITH ONE (1) LAYER OF 5/V TYPE 'X" FIRE RATED GYP. BD. ON BOTH SIDES OF 5TUD5.. ON 5ALE5 FLOOR SIDE, OVER LAYER OF TYPE "X' 6YP. BD. O.C. TO IN5TALL ONE (1) -LAYER OF 1/2° FKT. PLYWOOD TO 8'-0" A.F.F. WITH GYP. BD_ FILL FROM V -O° A.FF. TO ADJACENT CEILING AND ONE (1) LAYER OF 5/8' GYP. BD.-OVER-L&YER- + 3` P: W. -FILL `TO 7, ADJACENT GEILIN6. TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. ONE (1) LAYER OF GYP_ W. FILL FROM b' --O" A.F.F. TO ADJACENT GEILIN6 ON EXP05FD 51DE5 OF 5TUP5. ONE (U .LAYER OF 511)" 6YP. BD_ OVER LAYER OF PLYI"1DOD SALES AND 6YP. BD. FILL TO AOJAGIRT CE1LtN6. FLOOR LL. SIDE ONE (I) LAYER OF 5/8° TYPE "X" FIRE, RATED 6YP_ BD. ON Q BOTH 51DE5 OF 5TUD5 TU METAL DECK ABOVE. ° ONE (1) LAYER OF 1/2' PR.T. PLYWOODTo V-0" A.F.F. OVER LAYER OF TYPE °X" C2YP. BD_ ALIGN STUD KNOGKOV[5 (TYF',. FIN15H FLOOR. REFER TO 5HEET A -1b FOR MORE INFORMATION_ I ( I WALL BASE. REFER TO SHEET A -Lb FOR -MORE i INFORMATION. h 1 FLEXIBLE 5EALANT. ---TRACK AT FLOOR ANLL BOTTOM OF 5TRUGTURE ANCHORED AT A MAX. Of 2'-O' OL. `-�_GONGRFTE FLOOR 5LAB A55EMBLY. NOTE: WALL TYPE 'H° N N 1 -HOUR RATED WALL W/ PLYWOOD ONE SIDE A-1.5 A-1.4 A-1.1 SCALE: 3' = i'-0' w5-1rr-ply-I5ide 3 5/8' METAL 5TU05. ON 5ALE5 FLOOR SIDE OF 5TUD5 ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-O" AFF. WITH 6YP. BD. FILL FROM 8'-O" A.F.F. TO ADJACENT CEILING. OVER LAYER OF PLYWOOD AND 6YP. BD. FILL ONE (1) LAYER OF 5V GYP. BD. TO ADJACENT CEILING. ON DISPLAY WINDOW _DISP__LAY 51L1E5 OF SUJR:� ONE.(U I.AY�R OF, ill° F.R.T. PLYWOOD TO YItNDOW 17-02 ASF. WITH ` 6YP.'°13P: `FILL'`FRGI'1"12'-`0" AFF. TO I SIDE ADJACENT CEILING. OVER LAYER OF PLYWOOD AND 6YP. W. FILL ONE (1) LAYER OF 518" GYP. BD. TO ADJACENT 5ALE-5 CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINi51-t FLOOR u SIDE I -< ALIGN STUD KNO6KOUT5 (TYP). Q I I ry WALL BA5E. REFER TO 5HEET A 1.b FOR MORE INFORMATION. FIN15H FLOOR. REFER TO 5HEET A -lb FOR MORE INFORMATION. FLEXIBLE SEALANT. TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX_ OF 2-0' OL. CONCRETE FLOOR SLAB A55EMBLY. J J J ANTE CALFS FL ILAY INS ALL WALL TYPE °J" A-1.5 A-1.4 A-l.l SCALE: 3" = 1'-0' w5-ply-120hgt-I5ide b' METAL 5TUD5 ON SALES FLOOR SIDE OF STUDS ONE (1) LAYER OF 1/2" FRT. PLYWOOD TO 8'-0" A.F.F. WITH GYP. BD. FILL FROM 8'-O" A.F.F. TO 'ADJACENT CEILING. OVER LAYER OF PLYWOOD AND GYP. BD. FILL ONE '(1) LAYER OF 5/5' GYP. BD. TO ADJACENT CEILING. ON WARDROBE WARDROBE FIXTURE 51DE OF STUDS ONE (1) LAYER OF 5A8' GYP. BD. TO 3' ABOVE LEXTURE ADJACENT CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. I SIDE ONE (1) LAYER OF GYP. BD. FILL FROM 8'-O" A.F.F. TO 5ALEADJACENT CEILING ON EXPOSED 51DE5 OF STUDS. 5 -- ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-O' 51DE DR � �- F A.F.F. ON EXP05EP 51DE5 OF STUDS. Q I I ALIGN STUD KNOGKOUT5 (TYP). ` WALL BASE. REFER TO SHEET A-1.6 FOR MORE I14. INFORMATION. FLEXIBLE 5EALANT. ,,�FINISH FLOOR. REFER TO SHEET A-1.6 FOR MORE INFORMATION. AT FLOOR AND W TOM OF STRUCTURE M ANCHORED AT A MAX. OF 2'-0' O.G. CONCRETE FLOOR SLAB ASSEMBLY. �ffi� ARDROBENOTE L FL FI U WALL WALL TYPE "K" A-1.5 A-1.4 A-1.1 SCALE: 3' = 1'-0' w5_ply-g6hgt-I5ide ---- �"' DEM151N6'PARTITION - 3 5/8" METAL 5TUD5 WITH ONE (1) LAYER OF 518" GYP. BD. ON ` ' =----b" METAL STUDS WITH ONE (I) LAYER OF 5A8' METAL 5TUP5 ONLY BY LANDLORD. EXPOSED 51DE5 OF STUDS OVER ONE (1) LAYER OF 1/2" F.R.T. EXISTING ONE (1) LAYER OF 5/8" TYPE_ "X" PLYWOOD TO 8'-0' A.F.F. WITH GYP. W. FILL FROM 8'-0" A.F.F. TO FIRECODE GYP. BD. FIRE TAPED AND SEALED ADJACENT GEILIN6. TAPE AND SAND A5 s t ADJACENT CEILING. TAPE AND 5AND A5 REQUIRED TO ACCEPT FINISH. TO THE UNDERSIDE OF THE 5TRUGTURE ABOVE, REQUIRED TO AGGEPT FINISH. ---ONE (1) LAYER OF GYP. BD. FILL FROM 8'-0" A.F.F. TO ALIGN STUD KNOCKOUTS (TYP). .(1) LAYER OF 50" TYPE "X" FIREGODE GYP. ADJACENT CEILING ON EXP05ED 51DES OF STUDS. FINI5H FLOOR. REFER TO SHEET ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-0' I BD. FIRE TAPED AND SEALED TO°THE UNDERSIDE A-I.b FOR MORE INFORMATION A.F.F. ON EXPOSED SIDES OF STUDS. LC WALL BASE. REFER TO SHEET A -lb G.G. TO PROVIDE SOUND ATTENUATION ALIGN STUD KNOGKOU`T5 (TYP). FOR MORE INFORMATION. =� INSULATION IN DEMISING WALLS. i FLEX113LE SEALANT. ONE (1) LAYER OF 5/8" GYP. BD. ON EXPOSED SIDES OF STUDS. o -WALL BA5E. REFER TO SHEET A-I.b _-----------•CONGRETE FLOOR SLAB ASSEMBLY. r WALL TYPE 'D" FOR MORE INFORMATION. �'U / "P.� I A-1.5 A-1.4 A-1.1 SCALE: Y = 1'-0" w545t f FINISH FLOOR MATERIAL. REFER TO SHEET IFINISH n ft X r EXPOSED 51DE5 OF 5TUD5 OVER ONE (1) LAYER OF 112' F.R.T. 'A -I 'fOk' 6PE 1NFORMATION. FLOOR. REFER TO SHEET A -I.6 FORMORE INFORMATION. r PLYWOOD TO 8'-0' A.F.F. WITH GYP. BD. FILL FROM 8'-0" AFF. TO ADJACENT CEILING. TAPE AND 5ANO A5 REOUIRED TO ACCEPT FINISH. WALL 13A5E. REFER TO SHEET A -Ib FOR MORE INFORMATION. FLEXIBLE 5EALANT. l 1 4 4 a . ��-� - GONG. FLOOR SLAB ASSEMBLY. TENANT 5PAC,F A.P AGENT TENANT ONE (1) LAYER OF GYP. BD. FILL FROM V -O" A.F.F. TO LEASE LINE. FLEXIBLE SEALANT. / I ` TRACK AT FLOOR AND BOTTOM OF STRUCTURE ANCHORED AT A MAX. OF 2'-O' D.G. I 14OUR DEMISINGWALL �---- GONGRETE FLOOR 5LAB ASSEMBLY. A-1.5 A-1.4 & A-1.3 j SCALE: 3" = 1'-0" NOTE: WALL TYPE 'F" F SALES FLOOR WALL W/ PLYW IDES A--1.5 A-1.4 A41 SCALE: 3" = I'-0' ws-ply-%6 t-2side METAL 5TUD5 ON EXPOSED SIDES OF ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO ADJACENT CEILING WITH ONE (1) I I LAYER OF 5/8' 6YP. BD. OVER PLYWOOD TO ADJACENT CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. II ONE (1) LAYER OF 5/8' GYP. BD. ON 112" F.R.T. PLYWOOD. ON F-XP05ED SIDES OF STUDS ONLY. WALL BASE. REFER TO SHEET A -I.6 FOR MORE INFORMATION. TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX. OF 2'-0' O.G. FLEXIBLE 5EALANT. FIN15H FLOOR. REFER TO SHEET A-I.b FOR MORE INFORMATION. L7 I "IV" /1\ -------CONCRETE FLOOR SLAB A55EMBLY. NOTE: WALL TYPE "6' G G 3 5/8STUD FU K - OUT WALL / LYW A--1.5 A A-1.4 A A-1.1 SCALE: 3' = 1'-0' w5-35S5t_Py 3 5/8' METAL 5TU05 WITH ONE (1) LAYER OF 5/V TYPE 'X" FIRE RATED GYP. BD. ON BOTH SIDES OF 5TUD5.. ON 5ALE5 FLOOR SIDE, OVER LAYER OF TYPE "X' 6YP. BD. O.C. TO IN5TALL ONE (1) -LAYER OF 1/2° FKT. PLYWOOD TO 8'-0" A.F.F. WITH GYP. BD_ FILL FROM V -O° A.FF. TO ADJACENT CEILING AND ONE (1) LAYER OF 5/8' GYP. BD.-OVER-L&YER- + 3` P: W. -FILL `TO 7, ADJACENT GEILIN6. TAPE AND SAND A5 REQUIRED TO ACCEPT FINISH. ONE (1) LAYER OF GYP_ W. FILL FROM b' --O" A.F.F. TO ADJACENT GEILIN6 ON EXP05FD 51DE5 OF 5TUP5. ONE (U .LAYER OF 511)" 6YP. BD_ OVER LAYER OF PLYI"1DOD SALES AND 6YP. BD. FILL TO AOJAGIRT CE1LtN6. FLOOR LL. SIDE ONE (I) LAYER OF 5/8° TYPE "X" FIRE, RATED 6YP_ BD. ON Q BOTH 51DE5 OF 5TUD5 TU METAL DECK ABOVE. ° ONE (1) LAYER OF 1/2' PR.T. PLYWOODTo V-0" A.F.F. OVER LAYER OF TYPE °X" C2YP. BD_ ALIGN STUD KNOGKOV[5 (TYF',. FIN15H FLOOR. REFER TO 5HEET A -1b FOR MORE INFORMATION_ I ( I WALL BASE. REFER TO SHEET A -Lb FOR -MORE i INFORMATION. h 1 FLEXIBLE 5EALANT. ---TRACK AT FLOOR ANLL BOTTOM OF 5TRUGTURE ANCHORED AT A MAX. Of 2'-O' OL. `-�_GONGRFTE FLOOR 5LAB A55EMBLY. NOTE: WALL TYPE 'H° N N 1 -HOUR RATED WALL W/ PLYWOOD ONE SIDE A-1.5 A-1.4 A-1.1 SCALE: 3' = i'-0' w5-1rr-ply-I5ide 3 5/8' METAL 5TU05. ON 5ALE5 FLOOR SIDE OF 5TUD5 ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD TO 8'-O" AFF. WITH 6YP. BD. FILL FROM 8'-O" A.F.F. TO ADJACENT CEILING. OVER LAYER OF PLYWOOD AND 6YP. BD. FILL ONE (1) LAYER OF 5V GYP. BD. TO ADJACENT CEILING. ON DISPLAY WINDOW _DISP__LAY 51L1E5 OF SUJR:� ONE.(U I.AY�R OF, ill° F.R.T. PLYWOOD TO YItNDOW 17-02 ASF. WITH ` 6YP.'°13P: `FILL'`FRGI'1"12'-`0" AFF. TO I SIDE ADJACENT CEILING. OVER LAYER OF PLYWOOD AND 6YP. W. FILL ONE (1) LAYER OF 518" GYP. BD. TO ADJACENT 5ALE-5 CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINi51-t FLOOR u SIDE I -< ALIGN STUD KNO6KOUT5 (TYP). Q I I ry WALL BA5E. REFER TO 5HEET A 1.b FOR MORE INFORMATION. FIN15H FLOOR. REFER TO 5HEET A -lb FOR MORE INFORMATION. FLEXIBLE SEALANT. TRACK AT FLOOR AND BOTTOM OF 5TRUGTURE ANCHORED AT A MAX_ OF 2-0' OL. CONCRETE FLOOR SLAB A55EMBLY. J J J ANTE CALFS FL ILAY INS ALL WALL TYPE °J" A-1.5 A-1.4 A-l.l SCALE: 3" = 1'-0' w5-ply-120hgt-I5ide b' METAL 5TUD5 ON SALES FLOOR SIDE OF STUDS ONE (1) LAYER OF 1/2" FRT. PLYWOOD TO 8'-0" A.F.F. WITH GYP. BD. FILL FROM 8'-O" A.F.F. TO 'ADJACENT CEILING. OVER LAYER OF PLYWOOD AND GYP. BD. FILL ONE '(1) LAYER OF 5/5' GYP. BD. TO ADJACENT CEILING. ON WARDROBE WARDROBE FIXTURE 51DE OF STUDS ONE (1) LAYER OF 5A8' GYP. BD. TO 3' ABOVE LEXTURE ADJACENT CEILING. TAPE AND SAND AS REQUIRED TO ACCEPT FINISH. I SIDE ONE (1) LAYER OF GYP. BD. FILL FROM 8'-O" A.F.F. TO 5ALEADJACENT CEILING ON EXPOSED 51DE5 OF STUDS. 5 -- ONE (1) LAYER OF 1/2' F.R.T. PLYWOOD TO 8'-O' 51DE DR � �- F A.F.F. ON EXP05EP 51DE5 OF STUDS. Q I I ALIGN STUD KNOGKOUT5 (TYP). ` WALL BASE. REFER TO SHEET A-1.6 FOR MORE I14. INFORMATION. FLEXIBLE 5EALANT. ,,�FINISH FLOOR. REFER TO SHEET A-1.6 FOR MORE INFORMATION. AT FLOOR AND W TOM OF STRUCTURE M ANCHORED AT A MAX. OF 2'-0' O.G. CONCRETE FLOOR SLAB ASSEMBLY. �ffi� ARDROBENOTE L FL FI U WALL WALL TYPE "K" A-1.5 A-1.4 A-1.1 SCALE: 3' = 1'-0' w5_ply-g6hgt-I5ide ---- �"' DEM151N6'PARTITION - I ` ' =----b" METAL STUDS WITH ONE (I) LAYER OF 5A8' METAL 5TUP5 ONLY BY LANDLORD. EXISTING ONE (1) LAYER OF 5/8" TYPE_ "X" FIRECODE GYP. BD. FIRE TAPED AND SEALED ADJACENT GEILIN6. TAPE AND SAND A5 s t TO THE UNDERSIDE OF THE 5TRUGTURE ABOVE, REQUIRED TO AGGEPT FINISH. ALIGN STUD KNOCKOUTS (TYP). .(1) LAYER OF 50" TYPE "X" FIREGODE GYP. FINI5H FLOOR. REFER TO SHEET I BD. FIRE TAPED AND SEALED TO°THE UNDERSIDE A-I.b FOR MORE INFORMATION OF THE 5TRUCTURE ABOVE, TENANTS 51DE ONLY. WALL BASE. REFER TO SHEET A -lb G.G. TO PROVIDE SOUND ATTENUATION FOR MORE INFORMATION. =� INSULATION IN DEMISING WALLS. i FLEX113LE SEALANT. TRACK AT FLOOR AND BOTTOM OF 5TRUGTWE / -WALL BA5E. REFER TO SHEET A-I.b _-----------•CONGRETE FLOOR SLAB ASSEMBLY. r WALL TYPE 'D" FOR MORE INFORMATION. �'U / "P.� I A-1.5 A-1.4 A-1.1 SCALE: Y = 1'-0" w545t f FINISH FLOOR MATERIAL. REFER TO SHEET n ft X r EXPOSED 51DE5 OF 5TUD5 OVER ONE (1) LAYER OF 112' F.R.T. 'A -I 'fOk' 6PE 1NFORMATION. r PLYWOOD TO 8'-0' A.F.F. WITH GYP. BD. FILL FROM 8'-0" AFF. TO ADJACENT CEILING. TAPE AND 5ANO A5 REOUIRED TO ACCEPT FINISH. FLEXIBLE 5EALANT. l 1 4 4 a . ��-� - GONG. FLOOR SLAB ASSEMBLY. TENANT 5PAC,F A.P AGENT TENANT ONE (1) LAYER OF GYP. BD. FILL FROM V -O" A.F.F. TO LEASE LINE. NOTE: WALL TYPE "A" I 14OUR DEMISINGWALL SECT. (U.L. DESIGN#U465) A-1.5 A-1.4 & A-1.3 j SCALE: 3" = 1'-0" w5--lhr-dem ONE (1) LAYER OF 518' TYPE 'X" FIREGODE GYP. BD. FIRE TAPED AND SEAL ED TO THE UNDERSIDE OF THE 5TRUGTURE ABOVE, BOTH 51DE5. BRIDGING. AL -46N STUD-KNO( KOUTS. WALL BASE. REFER TO SHEET A -Ib FOR MORE INFORMATION. FINISH FLOOR MATERIAL. REFER TO SHEET A -I.6 FOR MORE INFORMATION. FLEXIBLE SEALANT. C,O%RETE FLOOR A55EM8LY. NOTE: WALL TYPE "B" _ � � � NFW 1 NSU WALL "L ISN U A-1.5 A-1.4 A-l.l `SCALE: 3' = I' -D' ws-Ihr • ti IQ u :at C C C r LL f o -- ONE LAYER EACH 51DE OF 5/8" GYP. v I I BD. OVER 3 518" METAL STUDS o SPACED Ib' O.G. LU --BRIDGING. LU ALIGN STUD KNOCKOUTS. LU ::::���WALL BASE. REFER TO SHEET A -Ib FOR MORE INFORMATION. TRACK AT FLOOR AND BOTTOM I OF STRUCTURE ANCHORED AT A I MAX. OF 2'-O". FINISH FLOOR MATERIAL REFER TO SHEET A -I.6 FOR MORE INFORMATION. GONGRETE FLOOR 5L AB A55EMBLY. NON -RATED p t NOTEt "Y G V'C'NN WALL SECTION'' I L 9 d WALL TYPE "G' A-1.5 A A--1.4 A-1.1 .SCALE: 3' = 1'-0' w5-prt-hgt OF STRUCTURE. DD NOT TO ROOF DECK. 5RAGE TO STRUCTURE ABOVE )F 4'-0" O.G. Wt METAL 5TUD5. FINISH. SEE REFLECTED PLAN FOR TYPES AND A.F.F. DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.09.Oq ❑ design dev. ❑ bidding IN permits 03,16.Og ❑ construction IM landlord prelim. 02.Oq.Oq N landlord final 02.27.0q REVISIONS: Prj. no. B -0q-012 Drawn RG, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: WALL SECTIONS AND DETAILS Sheet. no. I ` ' =----b" METAL STUDS WITH ONE (I) LAYER OF 5A8' GYP. BD. ON EXP05EP SIDES OF 5TUP5 TO ADJACENT GEILIN6. TAPE AND SAND A5 REQUIRED TO AGGEPT FINISH. ALIGN STUD KNOCKOUTS (TYP). FINI5H FLOOR. REFER TO SHEET I A-I.b FOR MORE INFORMATION WALL BASE. REFER TO SHEET A -lb FOR MORE INFORMATION. i FLEX113LE SEALANT. TRACK AT FLOOR AND BOTTOM OF 5TRUGTWE / ANCHORED AT A MAX. OF 2'-0" O.G. � _-----------•CONGRETE FLOOR SLAB ASSEMBLY. NOTE: WALL TYPE 'D" poll � D D IN METAL �'U / "P.� I A-1.5 A-1.4 A-1.1 SCALE: Y = 1'-0" w545t 1`W'METAL 5TUD5 WITH ONE (1) LAYER OF 5/8' 6YP. W. ON EXPOSED 51DE5 OF 5TUD5 OVER ONE (1) LAYER OF 112' F.R.T. PLYWOOD TO 8'-0' A.F.F. WITH GYP. BD. FILL FROM 8'-0" AFF. TO ADJACENT CEILING. TAPE AND 5ANO A5 REOUIRED TO ACCEPT FINISH. ONE (1) LAYER OF GYP. BD. FILL FROM V -O" A.F.F. TO IADJACENT CEILING ON EXP05ED SIDES OF 5TUD5, R.ECE55ED STANDARDS. REFER TO SHEET F-12 FOR LO( ATION5 AND MORE INFORMATION. ONE (1) LAYER 5/8' GYP, BD. OVER PLYWOOD AND 6YP. BD. FILL ON ALL EXPOSED SIDES OF 5TUD5. u: LINE OF EXISTING DEM151NG WALL. mom' ONE (1) LAYER OF 1/2' FRT. PLYWOOD TO 8'-O" A.F.F. ON EXPOSED SIDES OF 5TUD5. WALL BA5E. REFER TO 5HEET5 A -Ib FOR MORE INFORMATION. FIN15H FLOOR MATERIAL. REFER TO SHEET A-1.6 FOR MORE INFORMATION. TRACK AT FLOOR ANCHORED ® 2'-D" MAX. OL: NOTE: "F" WALL TYPE :�E FURRED -OUT ALL W/ PLYW 1 " ' a " ., I F•I LL A-1.5 A44 A-Lj SCALE: 3" = 1'-0' -ur-1585t-fur-full DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.09.Oq ❑ design dev. ❑ bidding IN permits 03,16.Og ❑ construction IM landlord prelim. 02.Oq.Oq N landlord final 02.27.0q REVISIONS: Prj. no. B -0q-012 Drawn RG, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: WALL SECTIONS AND DETAILS Sheet. no. F►TTIN6 ROOM A66E55ORY 56HEOULE ID.NO. DE56RIPTION MOUNTING HEIGHT MODEL NUMBER OPROVIDED WALL MOUNTED MIRROR LIGHT BOX BY OWNER, A55EMBLED 4 60" TO CENTERLINE OF ELEGTRIGAL 0 bidding N permits BOX FINAL HOOK UP BY ELECT. CONT. 0 construction IN5TALLED BY GG. tu 9 landlord final 02.27.09 MIRROR TO MATGH WIDTH OF FITTING OBY HALL MOUNTED MIRROR PROVIDED ROOM HALL. HEIGHT TO BE FROM OWNER d IN5TALLED BY GG. BASEBOARD TO &'-0" A.F.F. G 1'-5 3/4" A.F.F. TO BOTTOM OF 4'-7 I/W O5MALL ADJ. MIRROR H16H MIRROR. VERIFY WITH H +t M @L7 e. , v o —A PROJECT MANAGER _ I 5'-3" A.F.F. TO GENTERLINE. VERIFY HITH O CLOTHING RACK HITH RODS H 4 M PROJECT MANAGER istu 50 INTERIOR F.R. BENCH. ADA BENCH TO BE FLOOR SUPPORTED AND 16" ABOVE FIN15H FLOOR F.R. BEN( HE5 PROVIDED BY OWNER AND IN5TALLED BY 6.G. FASTENED TO HALL O HALL MOUNTED DOOR BUMPER ALI6N WITH DOOR HANDLE IN FIELD COORDINATE WITH DOOR HANDLE. OH/G GLOTHIN6 RAGK AND ROD5 45" ABOVE FINISH FLOOR �_',/ H/C FIT RM. DOOR 516NA6E 60" A.F.F. D.G., ON LATCH 51 -DE OF DOOR NOTE: MIRROR5 NOTED A5 ID. NO. 15HALL BE PLACED ON THE HALL ADJACENT TO THE LATCH 51DE OF THE DOOR. APAP FITTING ROOM &ENFRAL NOTF5: A. MIRROR TO BE MOUNTED ON HALL OPP051TE BENCH. B. BENCH TO BE ANCHORED TO ADJACENT WALL. G. CLEAR 5PAGE MU5T BE MAINTAINED. D. DOOR 5HING 15 NOT TO BE IMPEDED. E. L OGATION OF MIRROR AND BENCH TO BE IN5TALLED A5 SHORN ON PLAN5. f SCALE: 1 1/2" = I'=0" SCALE: N.T.S. 2" STEEL TUBE. 2 1/2" METAL STUD. REFER TO 5HEET5 A-1.1, A-1.2, A-1.3, A-1.4, AND A-1.5 FOR MORE INFORMATION. ui5-5t1-tube FITTING ROOM BACK AND 51DE HALLS TO BE 1/4" GYP. BD. OVER GONTINUOU5 1/2' F.R.T. PLYHOOD BLOGKIN6 ON METAL STUD FRAMING. (BOGKIN6 PROVIDED FOR ATTA( HMENT OF FITTING ROOM ACCESSORIES) REFER TO SHEETS A-1.1, A-1.2, A-13, A-1.4, AND A-15 FOR HALL TYPES AND A-5.1 FOR 5EGTION5.--- --,, J I 5 I I I _ I I I \ I \ I \\ L — i NOTE: FITTING ROOM DOOR5 AND PREFABRICATED JAMB A55EMBLIE5 5UPPLIED BY OHNER5 VENDOR AND PRE-FIN5HED. ALL INSTALLATION BY 6.6. 6.6. SHALL COORDINATE H/ SHOP DRAHIN6 FOR ROUGH OPENIN65. METAL STUD FRAMED HALL WITH F.R.T. WOOD NAILER5 ® JAMB5. REFER TO DOOR JAMB DETAIL #2/A-02 AND HALL TYPES ON 5HEET5 A-1.1, A-12, A-1.3, A-1.4, AND A-1.5 FOR MORE INFORMATION. p5- Ftng-rm J. )E, N ADA FI INS N , ALE: N.T..5. P6-ftng-rm NOTE: DOORS d JAMB ARE PREFABRICATED BY OHNER 5 VENDOR AND PRE -FINISHED. 6.G. 5HALL COORDINATE W 5HOP \ DRAHIN6 FOR ROUGH OPENINGS. ADA DOOR TO BE MIN. 3'-0" HIDE. I I I NOTE: G.G. SHALL LOCATE ADA FITTING ROOM FIXTURES AGGORDIN6 TO ENLARGED PLAt 4 FITTING ROOM AGGE%ORY SCHEDULE. A-l.l SCALE: 1/2' = 1'=0" %57ba5e ('2ENLARGED Fli"P`ING ROOD .PLAN SCALE: 1/2" 1'=0" 8070base 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright (D 2009 KEN NISCH, AIA All rights reserved Certification:�11�1 Fz jj � I AS OF Fj If o© p�ARS 6 ppm k8� Consultants: RETAIL DESIGN CONSULTANT JGA we 29110 Inkster Road Suite 200 Southfield,. Ml 48034 USA 248 355 0890 248 355 0895 Fax Cw),ight q> 2009 Xk Inc M www.jgo.com JGA Pr j #: 1-209-057 DRAWINGS ISSUED i=rvarrmr - FOR: ❑ programming 11 schematic des. 02.0q.Oq ru 0 bidding N permits 03.16.0q 0 construction landlord prelim. tu 9 landlord final 02.27.09 !u A F- Lii M G tu @L7 e. , v o —A I 0 J illi/ —j NX 0 istu Q C (j) 1 DRAWINGS ISSUED i=rvarrmr - FOR: ❑ programming 11 schematic des. 02.0q.Oq J design dev. 0 bidding N permits 03.16.0q 0 construction landlord prelim. 02.0q.0q 9 landlord final 02.27.09 REVISIONS: I Prj. no. 6-20q-012 Drawn RC, TH t. Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED FITTING ROOM PLANS Sheet no. I i A I CABINET a HARDN ; -E HNEAL NOTES A. ALL BACK OF HOU5E CABINETRY LAMINATE AND COUNTER TOP5 5HAL L BE NEVAMAR, 'BONE WHITE TEXTURED', MATTE FIN15H, 5-10-32-T. GOUNTERTOP5 IN THE TOILET ROOM5 AND LOUNGE SHALL BE "RIVER ROCK M05AI G'. B. WIRE PULL5, BACK MOUNTED, 4" LONG, 5/16' (8mm) IN DIA. G. PROVIDE MAGNETIG GAT6HE5, BHMA A15b.q,1303141. D. DRAWER 5LIDE5 TO BE RATED FOR 100 LBF AND SHALL BE FULL EXTEN510N, 51PE MOUNTED, ZING PLATED 5TEEL DRAWER 5LIDE5 WITH 5TEEL BALL BEARING, BHMA AI56.61, B050g1. E. PROVtD.E 2"X2° 5TEEL TUBE5 BELOW CaNTERTOP5 ,WHERE.5H0kN OR REQUIRED FOR EQUIPMENT ABOVE. F. ALL EXPOSED HARDWARE 5HALL BE NO. b52 FINI5HED. 6. FRAMELE55 CONCEALED HINGES (EUROPEAN TYPE): BHMA AI56A, 801602, SELF-GL051NG. H. ADJ1,15TABLE 5HELF 5TANDARD5 AND SUPPORTS: BHMA AI56.q, B04011: WITH 5HELF RE5T5, 13040bl. I. PROVIDE 5TAINLE55 5TEEL PIN5 FOR ALL ADJUSTABLE SHELVING. E3AGK OF HOUSE AGGESSORY SCHEDULE I D. NO. DE56RIPTION MANUFACTURER MODEL NUMBER LOCATION -� BOTTLED WATER REFER FURNI5HED AND INSTALLED BY I PER EMPLOYEES LOUNGE �JKJ D15PEN5ER --- TENANT 5 VENDOR TBD. ON 51TE B LOGKER5 DEBOUR&H MANUFACTURING FOUR (4) UNIT WIDE MODULE SEE FIXTURE PLAN FOR NUMBER REQUIRED 5HEET REFRIGERATOR GE. 65L25JFXLB I PER EMPLOYEES LOUNGE „ 1742 1GROXAVE -6f. JE -522515J I PER EMPLOYEE5 LOUNGE E GOAT RACK EMGO 5PEGIALITY PRODUGT5 EMGO MODEL RL -5'-O' LONG I PER 5TORE TBD. ON 51TE '^ 5TAINLE55 5TEEL KOR06ARD, TYPE 304 5TAINLE55 STEEL, F CORNER GUARD, CIO- BEND, 3 OR APPROVED 16 6AU6E, 04 5ATIN FINI5H 5EE DETAIL5 ON THI5 SHEET O. 1/2" WING, 4b" HIGH EQUA- PROVIDE IN -WALL 2x F.R.T. WOOD 5EGURING 5TANDARD5 AND GABINETRY. MASONITE WAINSCOT ----- __. I/4" THICTEMPERED REFER 70 PETS. #I, #5,K, __—_- z TO PROVIDE F.R.T. WOOD m WITH 2' LAMINATED BU! NOSE EDGE. #7, AND Ob ON THI5 5HEET HEAVY DUTY SURFACE MOUNTED 5HF1 F 5TANDARDS REFER REFER REFER REFER I I TO 11 W/ BRACKETS. LAMINATED 3/4" 12" DEEP MDF TO I_ _ _.: _ 5HEET 5HEET LAMINATED 3/4° 12° DEEP 5HEET 5HEET I F-12 WHERE SURFACE MOUNTED WALL I SHELVES, ONE PER BAY OF STANDARDS. 6.G. TO „ 1742 F -I.2, FOR 5EOJRI% OF 5TANDARD5. (TYP,) MDF SHELVES ONE PER 5TANDARD5 ARE PRESENT, G.G. TO PROVIDE F.R.T. WOOD BLOGKIN6 IN WALL FOR 3/4° LAMINATED MDF BOARD. BAY OF 5TANDARD5. OL. O. I I PROVIDE IN -WALL 2x F.R.T. WOOD 5EGURING 5TANDARD5 AND GABINETRY. i 2' THICK 2 ?' DEEP WORK 5URFAGE I I __—_- z TO PROVIDE F.R.T. WOOD m WITH 2' LAMINATED BU! NOSE EDGE. I I BLOGKIN6, INSTALLED I i o o ' „ 3 -I HOLD Q BLOCKING IN WALL FOR .fl -- �— I I VERTICALLY FROM FLOOR TO W36X30 CABINETRY WITH ONE AD STABLE ° --=---LL ' I U 1/�+° Q WOOD BLOCKING, IN5TALLEIP SECURING STANDARDS N HORVONTALLY BETWEEN 5TUP5, FOR AVAILABLE BRACING ABOVE, FOR INTERIOR SHELF f0 MATCH CABINET. e 5EGURIN6 OF CABINETRY. (TYP) i ' 1336 I AND CABINETRY. 5E6URIN6 OF STANDARDS. (TYP) 50LID 5URFAGE COUNTER TOP5 TO BE FORMICA GLA551G ----- - — I , o Q m NEW WALL, 5EE FLOOR PLAN 516NATURE 5ERIE5 it 656 'RIVER ROCK MGAIG'. FOR CON5TRUGTION TYPE. r 1'-2" °v G.G. TO PROVIDE IN -WALL 50LID 4" BACK5PLA5H (AT 51NK COUNTER, 5IZE0 A5 `'�- I I F.R.T. WOOD BLOCKING, REQ'D TO AL16N W/ ADJACENT) AND COUNTER TOP, ,A \ � o 4° BAGK51'lASN TO MATCH 2'-I 3/4" I IN5TALLED HORIZONTALLY I EXTENDING TO ADJACENT 51DE WALL, TO MATCH. N i � F= a COUNTERTOPS. 70P ED6E5 OF ALL SPLASHES TO ALIGN 2'-1' I I BETWEEN STUDS, FOR 5EGURIN7 o I I OF CABINETRY. (TYP) PROVIDE MAT(HIN6 FILLER PANELS AT BASE REQUIRE?. - i MICROWAVE, D :�r UNIT5 TO 56RIBE TO WALL. 5ECUREF A5 SINGLE COMPARTMENT 5TAItdLE55 STEEL SINK _ �— _-..T.— - ll I i I 1/2° THICK x 25" DEEP SOLID SURFACE COUNTER TOP _ I I NOTE: WITH MAXIMUM DEPTH OF 6-1/2". VERIFY 6AU6E II it ! I �� j— GENERAL CONTRACTOR W SPEGtFIGATIDNS. PROVIDE ADA COMPLIANT i II W/ BULL NOSE EDGE. I PROVIDED MILLWORK WILL GLFAARANGE5 AND LEVERS ON FALIGET. GL. TO { FORMICA CLA5516 o I I REQUIRE 5HOP DRAWING I' GUT GOLVTERTOP A5 REQD TO ACCEPT SINK. m 'T w ] 516NATURE 5ERIE5 # b56 m I I SUBMITTED TO TENANT AND N it "RIVER ROCK M05AIG . (TYP) " li N I I ARGHITEGT UPON AWARDINGEXPO5 1 TO BE �_- \ i / REFRIGERATOR. OF CONTRACT. ADA COMPLIANT 4 115ULATED. SE 5PE6I1`I6ATION5 ON MECHANICAL DRA1dEN65. _=-w- ` - _ _ —1 _� _—� NEW WATER LINE FOR `r REFRIGERATOR BY G.G. WALL_ . BASE. REFER TO 5HEET A-O.I AND PLUMBING 5HEET5 FOR MORE INFORMATION. 6 IONAL MASON �A-53j SCALE. N.T 5. C SCALE: 1/2' = V-0' CON5TRUIGTION_ (T'fP) CAULK. (TYP) CORNER 60ARD, �4b'�HI G�H. \! J MA5GWTE PAA i, a r5TALLED HORIZONtTALLY. (TYP) 4' ViTfL COVE BASE. (TYP) Int WAINSCOT I' METRIC W -n, iso--uxi5ct-boh 9tqL 5PAGE 5GREW .CEMENT PATTERN 50 THAT �AGH 5EAM WHERE IOININ5 PANEL5 MEET A d OF THREE (3) 5CR PRE5ENT A5 5HOWN. `moi i . " ; SCALE: 1/2' = 11-0' el -u zct-pn1 el-emp-Ing 8 A-5.3 i 3 1/2' 1 A -r, q :"� _�""- STAINLE55 STEEL CORNIER GUARD. f m ARrHITEGTURAL WALL. REFER TO r 5HEET5 A-I.I, A-12, A-1.3, A-1.4, AND A-1.5 FOR WALL 6ON5TRUCTION TYPE. MA50NITE PANEL5, ( G l r IN5TALLED HORIZONTALLY. (TYPJ A-5-3 -- rF WALL 6A5E BELOW. (TYP) v OPTIONAL MASONITE WAIN'SCOTRHE: GUARD DET. SCALE: G' = I' -O' ws-Lurrsct-f�nh 7 OPTIONAL A -53J SCALE: 6" = V-00 ►KITE PANEL, LLED HORIZONTALLY. D .n COVE BA5E. 11/7 TO SUPPORT rNITE 5i-EET5. MAWNITE WAINSCOTDETAIL Lu5-wmd--boh 7 W-� CABINETRY WITH TWD ADJUSTABLE INTERIOR NOTE: 6ENERAI- CONTRACTOR PROVIDED MILLWORK HL.L RARE.5HQP-PRAHt65. DI ITZP TO 'JD ANT AV ARCHITECT UPON AWARDIN6 OF CONTRACT. 5HELVE5 TO MATCH CABINET. FREE5TANDIN6 SAFE PROVIDED AND INSTALLED BY TENANT'S VENDOR. _ COORDINATE WITH TENANT FINAL LOCATION. 6:G. 'TO INSTALL TWO (2) HALL 5TOP5 FOR aAFE DOOR I, EO. J, EQ. HANDLE. COORDINATE LOCATION OF 5TOP5 �ITTH SAFE .D0OR 5WIN65 AND 2'-601° HANDLE LOLATIOR ..GL- TO IN5TALL ONE (1) LAYER OF 1/2" F.R.T. E . PLYWOOD BLOGKINC BETWEEN -CO) 5TUD5 IN LOCATION OF WALL 5TOP5. WALL 5TOP TO BE "IVES - - - - Ea. W5402CGV - °° o - Or rN TENANT DATA EQIPMENT.--------t— 56-5 3/4' ENLARGED BACK_ _Q_FFIOUSE PLAN SCALE: I/4' = I'-0' WALL MOUNTED GABINETRY WITH TWO At919-TABLE -INTERIOR -5HELVE5 TO MATCH CABINET. 5HELVE5 FINISHED ALL 51DE5. GENERAL CONTRACTOR WHERE 5URFA( E MOUNTED I TO PROVIDE F.R.T. WOOD BLOGKING IN HALL 5TANDARD5 ARE I WALL FOP. SECURING GABNETRY. PRE5ENT, G.G. TO PROVIDE IN -WALL 2x F.R.T. WOOD I 1/4" BACK PANEL LAMINATED TO BL06KIN6, IN5TALLED ° MATCH, WITH 5/b" MOUNTING RAILS. VERTICALLY FROM FLOOR TO I ( m AVAILABLE BRAGIN6 ABOVE, FOR 5EGURIN6 OF I I ccm 5TANDARD5 (TYP1. I I 3/4' DIVIDER PANELS LAMINATED I Tb+ATON'ON''t)tP65W SIDE5. 1� EG2, EQ. EQ. I I 6.6. TO PROVIDE IN -WALL I I 37 GROMMETS WITH GONERS, b" FROM FR.T. WOOD BLOCKING, I I BACK EDGE OF WORK 5URFAGE. 1'-5 ' 2'-6" I I 1145TALI-ED I I 2'-6° N I I HORIZONTALLY BETkEENI 2' THICK 30" DEEP WORK SURFAGE WITH a,. 5TU05, F ,�L�INbDF �° 2' LAMINATED BULL NOSE EDGE. EQ. (I GABINETRY (TYP), I ( 2'x2" TUBE 5TEEL T AT MID EQ. I I SPAN OF FORK SURFAGE. I ELECTRICALLY RAC Y: ' - 3/4' DIVIDER PANEL5 A5 5UPPORT FIN5 LAMINATED TO MATCH ON EXP05ED 51DE5. OPEN I I I l -2 112 OPEN OPEN BA5E CABIN_FT. 2° HIGH WOOD BASE. �,, I f i A--5.3 5CALE: 1/2" = I1-0' et-csh-off REFER REFER REFER REFER REFER REFER TO TO TO TO TO TO 5I-EET 5HEET 5HEET 5HEET 5HEET 5HEET F-1.2- F-12 F-1-2 F-1.2 „ 1742 F -I.2, I WFFRE SURFAG:E MOI NTED WALL ► L DRAWINGS ISSUED FOR- I' 0 programming 5TANDARD5 ARE PRESENT, 6L. TO • schematic des. 02.Oq.Oq 0 design dev. PROVIDE IN -WALL 2 x F.R.T. W009 11 permits 03.16.Oq 0 construction BLOCKING, N5TALLED VERTICALLY FROM M landlord prelim. 9 landlord final 02.0q.Oq 0227.Oq FLOOR TO AVAILABL F 5RA(,1% ABOVE, FOR 5EOJRI% OF 5TANDARD5. (TYP,) 3/4° LAMINATED MDF BOARD. O. I i 2' THICK 2 ?' DEEP WORK 5URFAGE I I m j WITH 2' LAMINATED BU! NOSE EDGE. m I I o o ' 4" TALL BAGK5PLA5H.- -- �— c� ° I C°C. To PROVM IN -WALL FRT. I U 1/�+° Q WOOD BLOCKING, IN5TALLEIP HORVONTALLY BETWEEN 5TUP5, FOR 5EGURIN6 OF CABINETRY. (TYP) i ' 1336 I I II o Q m NEW WALL, 5EE FLOOR PLAN FOR CON5TRUGTION TYPE. r °v 3 vu -46:0 ROOM. A--5.3 SCALE: 1/2' = 11-0' HEAVY DUTY SURFACE MOUNTED SHELF 5TANDARDj WITH BRAGKET5 AND (3) LAMINATED 3/4' x 12' DEEP GONTINUOU5 MDF 5HELVE5. GENERAL CONTRACTOR a ; TO PROVIDE IN -WALL F.R.T. WOOD BLOGKIN5 FOR ` ! SECURING OF STANDARDS AND GABINETRY. PLA5TIG LAMINATED WALL MTD. TABLE, PROJECTION v 441 LE65 AT OUTER EDGE, TO MATCH GOUNTERTOP. Y 2" THICK x 25' DEEP PLA5TIG LAMINATED WORK 5URFAGE IN LAMINATED BULL N05E EDGE. EXTEND SURFACE d 5PLA5H TO ADJACENT WALL. (TYPJ PL-A5TIG LAMINATED 4' BACK 5PL_A5N TO MATCH. O NO _ NOTE: / Bab GENERAL GONTRAGTOR PROVIDED MILLWORK WILL / REQUIRE 5HOP DRAWING 5UBMITTED TO TENANT / AND ARCHITECT UPON AWARDING OF CONTRACT. PROVIDE MATGHING FILLER PANEL 5 0 BASE UNITS TO 56RIBE TO HALL. 5EGURE A5 REOV. (TYP) a . BA5E. el-deco-rm REVISIONS: Prj. no. 8-209-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED BACK OF !! HOUSE FLAN AND i D�IL i Sheet no. I I i DRAWINGS ISSUED FOR- I' 0 programming • schematic des. 02.Oq.Oq 0 design dev. © bidding 11 permits 03.16.Oq 0 construction M landlord prelim. 9 landlord final 02.0q.Oq 0227.Oq REVISIONS: Prj. no. 8-209-012 Drawn RC, TW Checked ALS Approved KN Do not scale this print. Use figured dimensions only. Drawing title: ENLARGED BACK OF !! HOUSE FLAN AND i D�IL i Sheet no. I I i SCALE-- 1/2° = 1'-0° PI6TO6RAM BORDEI FIELD - MINIMUM b' I MINIMUM 518" HE16HT RA15ED 1/32", FULL OR 51MPLE SERIF TY CANNOT BE WITHIN B GRADE 2 BRAILLE. NESTROOI'I /-\U/-\ DI(;)JNM(��7C NOTE: MOUNTING HE16HT REFERENCE ONLY. REFER TO ENLARGED TOILET PLAN FOR ACTUAL LAYOUT. sheet file ADA FITTING ROOM SI�NA E INTERNATIONAL 516N FOR A;GGE551BILITY SCALE. N.T_5. -- el-oda-5gn EGRESS Q-5.4 SCALE: N.T.5. sheet-File TOILET ROOM AGGE55O Y SIGHEDUL ID. NO. DE5GRIPTION MANUFACTURER MODEL NUMBER' LOCATION OA TOILET TISSUE DISPENSER ------ FURNISHED BY TENANT, INSTALLED BY 6.6. REFER TO ELEVATIONS FOR MOUNTING HEIGHT ❑ construction IN landlord prelim, 02.0q.0q 119 landlord final 02.27.0, 3b" GRAB BARS REAR BOBRfGK 1-1/2' DIA. 5TAINLE55 5TEEL GRAB BAR W/ I, PER ADA COMPLIANT TOILET RMJ COMPARTMENT ON CONGEALED MTC, E� b84bx36 BAGK WALL OF WATER CLOSET, C) 42" GRAB BARS ® 51DE BOBRIGK 1-1/2' DIA. 5TAINLE55 STEEL GRAB BAR 1-l/ I PER ADA COMPLIANT TOILET RMIJ COMPARTMENT AT `-� CONCEALED MT6 B-bbObx42 51DE WALL. GOAT HOOKS BOBRICK 5-2116 1 PER TOILET COMPARTMENT, MOUNT AT 54' A.F.F. `E } SOAP DISPENSER -------- FURNISHED BY TENANT, INSTALLED BY G.G. 1 PER LAVATORY, TBD. ON SITE. MOUNT 50 (ENTER -� LINE OF P15PEN51NO ORIFICE 15 NO HIGHER THAN 40' A.F.F. PLATE 6LA55 MIRROR IN '- 5TAINLE55 STEEL FRAME BOBRIGK B-2�1O-2436 i PER LAVATORY _ PAPER TOWEL DISPENSER, -- ---- W - — ROLL TYPE — _ FURNISHED BY TENANT, INSTALLED BY 6.6. 1 PER TOILET ROOM, TBD. ON SITE. MOUNT AT 40' A.F.F. GARBAGE GAN ------- — FURNISHED BY TENANT, INSTALLED BY 6.G. 1 PER TOILET ROOM OA515 PbAG51- ADA COMPLIANT SPLIT LEVEL - ELECTRIC WATER COOLER FINISH: 5TAINLE55 STEEL CORRIDOR NEAR TOILET ROOMS. ®r- BRADLEY REFER TO SHEET A-02 FOR 5PEGIFIGATION REFER TO ENLARGED TOILET ROOM PLAN TOILET PARTITIONS TOILET ROOM HNERAL NOTES: A. NO OTHER MANUFACTURER 9UB5TITUTION5 SHALL BE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER FIVE (5) DAYS BEFORE BIDDING. B. CONTRACTOR SHALL SUBSTITUTE MODELS FOR LOW FLUSH WATER 61-05ET5 ONLY A5 REQ'D. BY LOCAL AND STATE CODE5. G. FIXTURE5 SHALL BE MOUNTED R1611) TO WALLS AND FLOORS. D. FIXTURES: ELDER, AM. STANDARD, OR KOHLER UNLE55 OTHEM15E NOTED. E. FITTINGS: ELDER, AM. STANDARD, KOHLER, DELTA, 5YMMON5 OR LEONARD. F. FLUSH VALVES: SLOAN VALVE CO., ZURN, OR DELANEY (MODIFIED TO NON -HOLD OPEN) 6. TOILET SEATS: CHURCH, OL50NITE, BENEKE OR BEMI5, CONTRACTOR SHALL PROVIDE OUTLET DEVISES WHICH LIMIT THE FLOW OF WATER TO LAVATORY TO A MAX. OF OS 6PM, 51NK5 TO A MAX. OF 3.0 GPM AS REQV BY LOCAL CODE. H. ALL PLUMBING FIXTURES SHALL BE WATER 5AVIN6 TYPE IN AG( ORDAN( E W/ CITY COVERNIN6 ADOPTED CODES AND REaLATION5. 1. NOTE: ALL TOILET ROOM A6CE55ORIE5 5UGH A5 TOWEL DISPENSER AND TOILET T155UE DISPENSER SHALL BE MOUNTED 50 THAT THE CENTER OF THE 06PEN51N6 ORIFICE OR CONTROL 15 NOT HIGHER THAN 40" A.F.F. J. WATER CLOSET TO BE PROVIDED kV 05GILLATING FL05H CONTROL HANDLE. OPERATING AT NOT GREATER THAN 5 L.B. FORGH AND WITHOUT EXGE551VE 130UY MOVEMENT. K. LAVATORY PROVIDED NEW FAUCET GONTROL5 OPERABLE WITH ONE HAND AND NOT REQUIRING 6RA5PIN6, PINGHING OR TWISTING. L. LAVATORY PROVIDE WITH NO ABRA51VE 5URFAGE5 UNDERNEATH. M. GRAB BARS TO HAVE A l 112" TO 1 1/4' GRO55 SECTION MTD 33" A.F.F. PROVIDE 1 112" CLEARANCE BETWEEN BAR AND WALL AND MOUNTED TO NITH5TAND A FORGE OF 300 L135. N. PROVIDE RESTROOM DOOR 516NA6E. MOUNT SIGN @ MIN. OF 5'-0" A.F.F. AND MAX. OF b' -O' A.F.F. 0. WATER GLOSET FLUSH VALVE TO BE MOUNTED ON THE WIDE 51PE OF THE TOILET AREA. P. 6.6. TO INSTALL FLOOR TILE IN BATHROOM AT 450 AN6LE TO WALLS. F1 TOILET ROOM KEY NOT5. NOTE: NEW ADA TOILET ROOM BY G.C. VERIFY ALL CONDITIONS. LINE OF TOP OF 5QUARE WAINSCOT TILE AT 4'-b" A.F.F., W/ BULLN05E TILE TRIM PIECE AND PAINTED GYP. BD. ABOVE. WATER CLOSET, W/ FLUSH VALVE ON TRANSFER SIDE. SEE SPEC,. ON ENGINEERING DRAWIN65. LAVATORY. SEE SPEC, ON EN6INEERIN6 DRAWINGS. (TYP) SMOOTH, NON-ABSORBENT FLOOR AND WALL MATERIAL. SEE DECOR PLAN SHEETS. MEWS TACTILE A.D.A. RESTROOM 516NA6E WITH BRAILLE. 56N TO BE MINIMM 6" 1-1161-1. REFER TO DETAIL 417 ON THI5 SHEET FOR MORE INFORMATION. 516N TO BE MOUNTED 60' A.F.F. ON LATCH 51DE OF DOOR. aWOMEN'S TACTILE ADA. RE5TROOM 5IGNA6E WITH BRAILLE. 51ON TO BE MINIMUM b" HI6i-i. REFER TO DETAIL #1 ON THI5 5HEET FOR MORE INFORMATION. 51GN TO BE MOUNTED b0" A.F.F. ON LATCH SIDE OF DOOR. (R } WALL MTD. AGGE55113LE URINAL. 1^k/ 14" RIM PROJECTION PER GHG SECTION 11155.2.1.1.1, AMERICAN STANDARD "ALLBROOK" 65-41.132. s ADA. COMPLIANT LAV. 6UARD. (TYP). OL)TSOLID5URFAGE r.WiTER 4 BAGK5PLA5H TO BE FORMICA CLA5516 516NATURE 5ERIE-5 # b5b 'RIVER ROCK M05AlG". AL►_ REQUIRED BLOGKIN6 BY G.GREFER Tp SHEET A-02 FDR MURF INFORMATION. COUNTER SUPPORT BRACKET. TWO (2) LAYERS 3/4" F.R.T. PLYWOOD, W/ LAMINATE FIN15H TO MATCH COUNTER. ALL REQUIRED BLOCKIN6 BY 6.G, WAINSCOT TILE. F.R.T. BLOCKING AS REQUIRED. - PLATE GLA55 MIRROR. PLATE GLASS MIRROR. F.R.T. BLOCKING A5 REQUIRED. `l—WAINSCOT TILE. I NOTE: MOUNTIN6 HEIGHT REFERENCE ONLY. REFER TO ENLARGED TOILET PLAN FOR ' . ' � � ,�' ACTUAL LAYCUT, A-.5.4 5CALE: 1/2' = I'-0" sl�oiy l�.te SCALE: 1/2' = 1'-0" NOTE: MOUNTIN6 HEIGHT REFERENGE ONLY. REVERSE CONDITIONS APPLY. REFER TO ENLARGED TOILET PLAN FOR ACTUAL LAYOUT. sheet file 351-03/41, [10 WE .� 1 RI,':,f �. SCALE: 1/2" = 1'-0" g057base NOTE: MOUNTING HE16HT REFERENCE ONLY. REVERSE CONDITIONS APPLY. 'REFER TO-ENLARGED`TOILET PLAN FOR ACTUAL LAYOUT. sheet file ELEVATION. SCALE: 1/2" = 1'-0° NOTE: MOUNTING HEIGHT REFERENCE ONLY. REVERSE CONDITIONS APPLY. ;REFER -TO ENLAR5E9T.DILET-PLAN FOR ACTUAL LAYOUT. �5hed-file 25 DRAWINGS ISSUED FOR: D programming N schematic des. 02.0,.0, fJ design dev. O bidding ill permits 03.16.0, ❑ construction IN landlord prelim, 02.0q.0q 119 landlord final 02.27.0, REVISIONS: i I' ,I li �i Prj. no. 8-209-012 f Drawn RC, TW Checked ALS Approved KN i Do not scale this print. Use ,."": figured dimensions only. Drawing title= ENLARGED TOILET ROOM PLAN AND DETAILS Sheet no.cum 5 TOP OF METAL DECK. MINERAL FIBER. BOTTOM OF METAL DECK. FIRE RATED 6YP5UM COMPOUND OR FIRE CAULK (TYP). FIRE TRAK SHADOWLINE. A55EMBLY PROVIDE5 FOR I" DEFLECTION 5/8" TYPE 'X' GYP. BD. METAL STUD. NOTE: COORDINATE METHOD OF ATTACHMENT ON 51TE WITH RODNEY MAG6ARD. CIN DEFLECTION WALL N (1 -HR. RATED) PERPENDICULAR 10 METAL DECK U.L. 14W -D-0060 56ALE: 3" = 1'-0" w5-Ihr-df Ict-head LINE OF WALL. LINE OF CEILING AT DECOR ROOM. r 4 i -r LOCATE BOTTOM ROW OF 5 (RAPPING NEAR FIN15H FLOOR. 11, B", � -, 56ALE: 1/2' = 1'-0' w5-boh-5trpnq 56ALE: 1/2" = 1'-0' a F--1 2 5GALE: 1/2" = 1'-0' LINE OF WALL. �NU GEILIN6 / EXP05ED TO STRUCTURE ABOVE 0 T - t � I u LOCATE BOTTOM ROW OF 5TRAPPI% AT FIN15H FLOOR. ROW OF FIN15HH FLOOR. 19 ws-boh-strpng TOP OF METAL DECK_ FIRE RATED 6YP5UM COMPOUND OR FIRE CAULK (TYP). %-GL1P -'T WIDTH. �v = BOTTOM OF METAL DECK. i �- FIRE TRAK SWOOHLINE. A55EMBLY PROVIDES FOR I" DEFLECTION 5/5" TYPE 'X' GYP. BD. METAL STUD. NOTE: COORDINATE METHOD OF ATTACHMENT ON 51TE WITH RODNEY MAG6ARD. SECTION DEFLECTION'WALL (1-14R. RATED) A L L �I AL C U.L. N A--5.5 1 �A-E• 3' = I' -On w5-Ihr-dI`IGt-head 0 6.6. TO GUT GAP FROM ADDITIONAL WALL PANEL(5) SUPPLIED BY OWNER TO GAP END5 OF FIXTURE. TYP. ALL EXP05ED ENDS. REFER TO DETAIL #2 ON THI5 5HEET FOR MORE INFORMATION. GAP TO BE FLUSH TO AD.JAGENT PANEOWALL. 5URFAGE MOUNTED STANDARD AND WALL PANEL 5Y5TEM 5UPPLIED BY OWNER. Ix 01-06KIN6. 2 1/2" METAL STUD WITH ONE (1) LAYER OF 1/2" PLYWOOD ON 5ALE5 FLOOR 51DE FACE OF 5TUD5. WALL 60145TRUGTION. REFER TO 5HEET5 A-I.I, A-1.2, A-1.3, A-1.4, AND A-1.5 FOR TYPE AND MORE INFORMATION. NOTE: 6.C. TO MAINTAIN INTEGRITY OF FIRE -RATING FOR 6ON5TRUGTION OF WALL BUILD -OUT. 1 1 POP -OUT ALL A A / I 'U PLAN AIL A-3.2 A A-5.5 J 5GALE: 3" = 1'-0' w5-5tnd-pnl 2U' FALL A-.3.2 - F-1.2 5GALE: 3" = 1'-0' LU v� MKI-SIMU, Xi. UZZ.-JU -O GAP EN05 OF POP -OUT WITH BD. TO HIDE L16HT5. PAINT TO H ADJACENT WALL (TYP). GAP TO 16H WITH TOP OF ADJACENT L. REFER TO DETAIL #1 ON THI5 f FOR MORE INFORMATION. 1) LAYER OF 1/2' PLYWOOD ON \ND BOTTOM OF EUILD-OUT. G.G. \INT TO MATCH ADJACENT WALL. �GKING. NGE MOUNTED STANDARD NALL PANEL 5Y5TEM _IED BY OWNER. 60145TRUGTION. REFER TO 5HEET5 A-1.2, A-13, A-1.4, AND A-15 FOR AND MORE INFORMATION. 'METAL STUD WITH ONE (1) R OF 1/2' PLYWOOD ON 5ALE5 ,R 51DE FACE OF 5TUD5. 'GO ADJ05TABLE FLUORE5( ENT LIGHT )P AND BOTTOM OF BUILD-OUT5. 75 TO BE 5TAG6ERED TO ELIMINATE ,IBLE DARK 5POT5. LIGHTING TO BE SHED AND IN5TALLED BY G.G. REFER -ECTRICAL 5HEET5 FOR MORE :MATION. TO GAP EN05 OF POP -OUT WITH BD. TO HIDE LIGHT5. PAINT TO ',H ADJACENT WALL (TYP). GAP E FLUSH WITH BOTTOM OF AGENT PANEL. REFER TO DETAIL 01 -115 5HEET FOR MORE INFORMATION. TO MAINTAIN INTEGRITY OF -RATING FOR 6ON5TRUCTION ALL BUILD -OUT. . BA5E. 5GALE: 3' = 1'-0" w5-5tnd-5rF-mtd 56ALE. 3" = 1'-0" 15TUD5. REFER TO 5HEET5 A-I.I, A-1.2, , A-1.4, AND A-15 FOR MORE INFORMATION. F.R.T. PLYWOOD. GYPSUM BOARD . :AGE MOUNTED STANDARD W/ FLOOR J -CHANNEL, VIDED BY OWNER, INSTALLED BY G.G. -FAB. WALL PANEL PROVIDED BY OWNER, 4,LLED BY G.G. w5-5tnd-5rF-mtd--ply METAL STUDS. REFER TO 5HEET5 A-I.I, A-12, A-1.3, A-1.4, AND A-1.5 A-I.I, A-1.2, A-1.3, A-1.4, AND A-15 FOR MORE INFORMATION. w ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD N FOR MORE INFORMATION. - --- -5/8" 6YP5UM BOARD. 3" Ib 6A. MTL. STRAPPING, SPACED U DOUBLE 5LOTTED, REFER TO Ib" O.G. HORIZONTAL. MOUNTING HEIGHT. TO BE PROVIDED BY OWNER AND IN5TALLED BY O.G. 248 355 0890 _-- 5/8" 6YK::5UM BOARD. nn lot-. d ujv�-5URFAGE MOUNTED STANDARD, JGA Pr j #: DOUBLE 5LOTTED, REFER TO ` I� I I;! I ELEVATION5 ON THI5 5HEET FOR MOUNTING HEIGHT. TO BE PROVIDED BY OWNER AND I145TALLED BY 6.G. U FAC - _ UNC' _ STANDARD _m . .. 5GALE: 3' = 1'-0" w5-5tnd-5rF-mtd 56ALE. 3" = 1'-0" 15TUD5. REFER TO 5HEET5 A-I.I, A-1.2, , A-1.4, AND A-15 FOR MORE INFORMATION. F.R.T. PLYWOOD. GYPSUM BOARD . :AGE MOUNTED STANDARD W/ FLOOR J -CHANNEL, VIDED BY OWNER, INSTALLED BY G.G. -FAB. WALL PANEL PROVIDED BY OWNER, 4,LLED BY G.G. w5-5tnd-5rF-mtd--ply 5GALE: 3" = 1'-0" w5-5tnd-5rF-ply 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification:;C'1��5 J,26 kk many®� tom; , °e, 4 Consultants: METAL 5TUD5. REFER TO 5HEET5 A-I.I, A-12, A-1.3, A-1.4, AND A-1.5 FOR MORE INFORMATION. w ONE (1) LAYER OF 1/2" F.R.T. PLYWOOD N TO EXTEND FULL HEIGHT OF WALL. - --- -5/8" 6YP5UM BOARD. Suite 200 51)RFAGE MOUNTED 5TANDARD, DOUBLE 5LOTTED, REFER TO ELEVATIONS ON THI5 5HEET FOR MOUNTING HEIGHT. TO BE PROVIDED BY OWNER AND IN5TALLED BY O.G. 5GALE: 3" = 1'-0" w5-5tnd-5rF-ply 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification:;C'1��5 J,26 kk many®� tom; , °e, 4 Consultants: RETAIL DESIGN CONSULTANT JIGA m 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fox nn lot-. d www.jgo.co"n I, JGA Pr j #: 1-209-057 ` I� I I;! I I �i tgtu Lill iD LLI q 4 .2 LLA J � x EL DRAWINGS ISSUED FOR: ❑ programming i N schematic des. 02.0q.09 �' I O design dev. ❑ bidding N permits 03.16.Oq ❑ construction N landlord prelim. 02.0q.09 N landlord final 02.27.001 REVISIONS: G' i i' �1 Prj. no. —20q-01 Drawn RG, TW Checked ALS Approved KN Ir Do not scale this print. Use i. figured dimensions only. . L Drawing title: MISCELLANEOU5 DETAILS ,. Sheet no. A now i'r : NOTE 14 QUANTITY AS SHOWN ON PLANS 2-#14 & 1-#18 TWISTED \SHIELDED PAIR LCD REMOTE ANNUNCIATOR PANEL FIRE ALARM EXTENDER 6-#14 PANEL_ DIGITAL COMMUNICATOR 120VAC TO 20A, 1P BREAKER. LOCK -ON {- & MARK RED IJGA-21 2 PHONE LINES TO MAIN TELEPHONE BOARD OR TO SECURITY PANEL VERIFY WITH H&M ON-SITE. 18 AWG TWISTED SHIELDED PAIR ADDRESSABLE ADDRESSABLE PULL STATION SMOKE & HEAT DETECTORS WIRE HORN/STROBES & STROBES SEPARATELY FOR SYNCHRONOUS OPERATION VERIFY LOCATION & QUANTITY IN FIELD WITH LANDLORD'S REP. PRIOR TO ROUGH IN 2-#14 AWG TO FAN CONTROLLER FOR SHUTDOWN 2 -CONDUCTOR #14 AWG _ N;WMr11 FIX" :111111 4-#16 AWG TO ADDITIONAL DEVICES. PROVIDE E.O.L. RESISTOR AT END OF CIRCUIT. (TYPICAL) TO ADDITIONAL DEVICES. FIRE ALARM SYSTEM SYMBOL LEGEND DRE ALARM SYSTEM NOTES: DESCRIPTION FIRE ALARM SYSTEM SPECIFICATIONS CEILING -MOUNTED SMOKE DETECTOR CATALOG FIRE ALARM HORN/STROBE DEVICE D 1. THE SYSTEM DESIGN SHOWN AND DESCRIBED IN THE CONSTRUCTION SPRINKLER SYSTEM FLOW SWITCH BY FPC WIRED BY E.C. COORDINATE WITH COORDINATE FIRE ALARM SYSTEM INSTALLATION WiTH LANDLORD FOR MECHANICAL CONTRACTOR. DOCUMENTS REPRESENTS THE MINIMUM REQUIREMENTS OF THE SPRINKLER SYSTEM TAMPER SWITCH BY FPC WIRED BY E.C. COORDINATE WiTH "REQUIRED FIRE ALARM CONTRACTOR" FOR FINAL CONNECTION TO MECHANICAL CONTRACTOR. BUILDING OWNER/TENANT. THE ELECTRICAL CONTRACTOR SHALL DUCT -TYPE SMOKE DETECTOR WITH REMOTE TEST STATION PROVIDED BY MECHANICAL LANDLORDS CENTRAL FIRE ALARM SYSTEM. CONTRACTOR, WIRED BY E.C. - INSTALLED IN DUCTWORK BY MECHANICAL BE RESPONSIBLE TO VERIFY ALL REQUIREMENTS WITH THE LOCAL CONTRACTOR PER CODE. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR www.ba.com & MANUFACTURER. PROVIDE CONDUIT & WIRING NECESSARY TO SHUT DOWN AUTHORITIES PRIOR TO BIDDING AND INCLUDE THE COST OF ALL 1. EQUIPMENT: ALL DEVICES, COMBINATIONS OF DEVICES, APPLIANCES FIRE ALARM CONTROL PANEL REQUIRED ALARM SYSTEM COMPONENTS IN HIS BID. THE COMPLETED MANUAL PULL STATION MOUNTED 48" AFF TO TOP. AND EQUIPMENT SHALL BE LISTED FOR THE PURPOSE FOR WHICH THEY LANDLORD JUNCTION BOX TiE-IN SYSTEM MUST MEET ALL STATE AND LOCAL CODE REQUIREMENTS FIRE ALARM ANNUNCIATOR ARE USED AND SHALL BE INSTALLED IN COMPLIANCE WITH APPLICABLE 20A -2P -3W -125V GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 18" A.F.F., AND MALL OPERATIONS CRITERIA. U.O.N. CODES AND STANDARDS. 2. ALL WIRING SHALL BE IN CONDUIT AND SHALL BE SIZED AS PER 2. PROVIDE A COMPLETE, SUPERVISED, POWER -LIMITED, ADDRESSABLE FIRE ALARM 20A -2P -3W -125V ISOLATED GROUND TYPE DUPLEX RECEPTACLE MOUNTED THE NATIONAL ELECTRIC CODE, DO NOT RUN ANY OTHER WIRING 18" A.F.F. U.O.N. SYSTEM SYSTEM TO BE COMPATIBLE WITH LANDLORD FIRE ALARM SYSTEM IF 20A -2P -3W -125V ISOLATED GROUND TYPE DOUBLE DUPLEX RECEPTACLE MOUNTED IN THE SAME CONDUIT WiTH ALARM WIRING. DO NOT RUN 120VAC 18" A.F.F. U.O.N. REQUIRED. OTHERWISE, PROVIDE EDWARDS SYSTEM TECHNOLOGY FIRE ALARM 20A -2P -3W -125V GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE MOUNTED WIRING WITH ALARM WIRING. USE OF NON-METALIC CONDUIT 48" A.F.F., UNLESS NOTED OTHERWISE. SYSTEM THAT CAN BE MONITORED BY H&M SECURITY. 20A -2P -3W -125V SPLIT (2 -CIRCUIT) GROUNDING TYPE DUPLEX RECEPTACLE REQUIRES 112 DRAIN WIRE TO MAINTAIN CONTINUITY OF SYSTEM MOUNTED AT 18" A.F.F., UNLESS NOTED OTHERWISE. ONE CIRCUIT SHALL FEED F�-- TOP HALF AND ONE CIRCUIT SHALL FEED BOTTOM HALF OF RECEPTACLE. GROUNDS AND All OTHER WIRE SHIELDED CABLE. 3. THE FIRE ALARM SYSTEM SHALL BE AN ELECTRICALLY SUPERVISED SYSTEM, INDICATES CODED NOTE El DOORBELL PUSH BUTTON MTD. 48" A.F.F. WHICH SHALL MONITOR THE INTEGRITY OF CIRCUIT CONDUCTORS AND 3. ALL WIRE AND CABLE MUST BE RATED PER THE LATEST REVISION MANUAL MOTOR STARTER WITH SIZED OVERLOAD PROTECTION. POWER SUPPLIES. LIGHTING CONTROL TIME CLOCK OF THE NATIONAL ELECTRIC CODE SECTION 760. LIGHTING CONTROL OVERRIDE KEY SWITCH 0 SPEAKER, FLUSH MOUNTED U.O.N. P 4. THE INSTALLATION ORGANIZATION SHALL BE A COMPANY SPECIALIZING 4:- WIRING SHOWN ON THIS DIAGRAM REPRESENTS THE MINIMUM SIZE COMMUNICATIONS OUTLET MOUNTED 18" AT A.F.F. U.O.N. IN THE INSTALLATION OF FIRE ALARM SYSTEMS. THIS ORGANIZATION PROVIDE CONDUIT SIZED PER SPECIFICATION'S FILL REQUIREMENTS REQUIRED. WIRE SIZES SHALL BE INCREASED AS REQUIRED FOR (3/4 MINIMUM) TO DATA RACK IN LAN ROOM WITH CABLING PER SHALL HAVE A MINIMUM OF FIVE YEARS EXPERIENCE WITH INSTALLATION SPECIFICATIONS. 'W ADJACENT TO SYMBOL INDICATES WALL MOUNTED AT VOLTAGE DROP. 54" A.F.F. REFER TO RESPONSIBILITY SCHEDULE SECTION 16740 OF SUCH SYSTEMS. 5. THIS DIAGRAM IS NOT INTENDED TO SHOW QUANTITIES OF DEVICES. 5. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ON THE SITE AN NUMBER ADJACENT TO SYMBOL DEFINES THE QUANTITY OF CABLES SM,BM SILVER OR BRONZE MIRROR THE FULL HEIGHT AND WIDTH OF THE COLUMN FROM UP-TO-DATE RECORD SET OF APPROVED SHOP DRAWINGS. 6. ALL CONDUCTORS INCLUDING SHIELDS MUST TEST FREE OF OPENS, THE BASEBOARD TO CEILING. FURNISHED AND INSTALLED BY OTHERS. }- MOTORIZED DAMPER WIRED BY ELECTRICL CONTRACTOR. SHORTS AND GROUNDS BEFORE MAKING CONNECTIONS TO THE 6. RECORD DRAWINGS SHALL INCLUDE LOCATION OF END -OF -UNE DEVICE DOME CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY E.C.. SUPERVISORY ALARM CONTROL PANEL FIXED CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY E.C.. LOCATIONS. 7. 120 VAC POWER TO CONTROL PANEL REQUIRES A DEDICATED 7. UPON COMPLETION OF THE WORK, AND FINAL ACCEPTANCE BY THE LOCAL CIRCUIT. RUN 3 #12 (INCLUDES THE GREEN GROUND WIRE) TO AUTHORITY, THE CONTRACTOR SHALL SUBMIT RECORD DRAWINGS TO THE 120VAC 60HZ USING 20 AMP CIRCUIT BREAKER. PROVIDE A LOCK -ON ACCESSORIES: OWNER. CUP AND RED MARKING ON THE BREAKER. 8. A REMOTE MONITORING FACILITY OUTPUT CIRCUIT, SELECTABLE FOR 8. SMOKE DETECTOR HEADS MUST BE INSTALLED FREE OF DUST OR INTERFACE TO REMOTE STATION REVERSE POLARITY, LOCAL ENERGY 92 ANY OTHER CONTAMINATION. CDM35/T4/830 MASTER BOX, SHUNT MASTER BOX, DIGITAL ALARM COMMUNICATOR, OR - 2 -LAMP 39W METAL HALIDE ADJUSTABLE ACCENT 911601 RADIO TRANSMITTER MONITORING SYSTEMS, SHALL BE PROVIDED. THE 9. ALL DEVICES TO BE FIELD TESTED WITH WRITTEN CERTIFICATION EQUIPMENT SUPPLIER MUST CONTACT THE LOCAL AUTHORITIES PRIOR TO OF SYSTEM. PERFORM ALL TESTS IN THE PRESENCE OF THE FIXTURE WITH ELECTRONIC BALLAST. 277VAC BIDDING AND SUPPLY ALL REQUIRED EQUIPMENT IN BASE BID. AUTHORITY HAVING JURISDICTION. 9. CONTROL PANEL SHALL BE CAPABLE OF MONITORING ALL FIRE ALARM 10. PROVIDE CONNECTION TO REMOTE SUPERVISION AS DIRECTED FOR C DEVICES INDICATED IN WIRING DIAGRAM AND SHOWN ON THE 1 SUPERVISION OF SYSTEM IN COMPLIANCE WITH LOCAL AUTHORITY SPECIALTY LIGHTING CONSTRUCTION DOCUMENTS. THE POWER SUPPLY SHALL BE ADEQUATE 6" RECESSED 42W COMPACT FLUORESCENT OPEN AND OWNER. PROVIDE ALL INTERFACE REQUIRED TO INTIATE 61 TO SERVE CONTROL PANEL MODULES. RELAYS AND ALARM INDICATING REMOTE SUPERVISION. APPLIANCES. INCLUDE A SECONDARY EMERGENCY POWER SUPPLY ITEM #:US1400ES DOWNUGHT WITH INTEGRAL EMERGENCY BATTERY PACK WITH CAPACITY FOR OPERATING SYSTEM IN STAND-BY MODE FOR 11. PROVIDE AND INSTALL A CEILING MOUNTED SMOKE DETECTOR IN 24 HOURS FOLLOWED BY ALARM MODE FOR 10 MINUTES. FRONT OF THE FIRE ALARM PANEL IN ADDITION TO THE AND INTEGRAL TEST SWITCH CLEAR ALZAK REFLECTOR DEVICES SHOWN ON THE FLOOR PLANS. 10. ADDRESSABLE PULL STATIONS SHALL BE SEMI -FLUSH, ACTION PUSH/PULL 0-20888, 1951 E. 12. PROVIDE AND INSTALL MANUAL STATIONS WHERE REQUIRED BY E 23 1 LOCAL AUTHORITIES TO MEET THE REQUIREMENTS OF NEPA-72 11. SMOKE DETECTORS SHALL BE ANALOG PHOTOELECTRIC TYPE. PROVIDE 4.5" RECESSED 20W METAL HALIDE DOWNLIGHT WiTH SECTION 3-8.1.2 IN ADDITION TO THE DEVICES SHOWN ON THE 14 WITHAUXILIARY RELAY FOR ELEVATOR RECALL WHERE INDICATED WITH "E". PLANS. VERIFY WITH LOCAL AUTHORITY PRIOR TO BIDDING AND A SUBSCRIPT ITEM #:91121 INDICATE COST IN BID PRICE. 12. DUCT -MOUNTED SMOKE DETECTORS SHALL HAVE A BASE WiTH 13. THE ELECTRICAL CONTRACTOR SHALL SUBMIT FIRE ALARM SYSTEM REFLECTOR, CLEAR GLASS LENS, AND WHiTE TRIM AUXILIARY RELAY, ANALOG PHOTOELECTRIC DETECTOR, SAMPLING DRAWINGS AND SPECIFICATIONS TO THE LOCAL FIRE DEPARTMENT TUBES (LENGTH AS REQUIRED) AND DUCT DETECTOR REMOTE KEY FOR REVIEW AND APPROVAL BEFORE ROUGH -IN OF FIRE ALARM - RESET/TEST STATION WITH ALARM LED. SYSTEM DEVICES AND EQUIPMENT. G 64 14. PROVIDE 6#14 & CONDUIT FROM FIRE 4LLARM CONTROL PANEL TO 13. SEMI -FLUSH AUDIOVISUAL UNIT SHALL BE WITH A.DA COMPLYING CANDLA 4'-0" LONG CHAIN MOUNTED ESCENT FIXTURE. LANDLORD'S FIRE ALARM JUNCTION BOX IN THE MALL'S CORRIDOR VERIFY ON LIGHTING SERIES WITH ADA COMPLYING MULTI-CANDLA STROBE AND SPEAKER. ALL (VERIFY LOCATION W/ LL) FOR MONITORING OF STATUS, TROUBLE STROBE LIGHTS SHALL BE SYNCHRONIZED. FKR-126, WITH LAMP AND ALARM CONDITIONS. ADDITIONAL DEVICES, FINAL CONNECTIONS PLANS AND PROGRAMMING TO BE MADE BY LANLORD'S FIRE ALARM 14. VISUAL ONLY UNIT A.DA COMPLYING MINIMUM 75 -CANDELA STROBE. CONTRACTOR AT H&M'S EXPENSE. 0 ALL STROBE LIGHTS SHALL BE SYNCHRONIZED. H 15. PROVIDE AND INSTALL WIRING PER MANUFACTURERS' SPECIFICATIONS. F32T8/830/ALTO DAY-BRiTE 2TG8332-21-UNV- ALL WIRING SHALL BE IN CONDUIT (3/4" MINIMUM). N/A VERIFY ON LIGHTING 16. THE COMPLETED FIRE ALARM SYSTEM SHALL BE FULLY TESTED IN ACCORDANCE WITH NFPA-72H, AND LOCAL FIRE DEPARTMENT REQUIREMENTS, .125" ARCYLIC PRISMATIC LENS, FLAT STEEL DOOR PLANS BY THE INSTALLER, IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE AND THE LOCAL FIRE MARSHALL UPON COMPLETION OF A SUCCESSFUL (ADD "E5" AS REQUIRED) AND ELECTRONIC BALLAST. 277VAC. NOTE 3 TEST, THE INSTALLER SHAH SO CERTIFY, IN WRITING, TO THE OWNER J 44 1 AND GENERAL CONTRACTOR. SPECIALTY LIGHTING 6VF142TE4-6VFSCL 17. INCLUDE ON-SITE SERVICES OF A CERTIFIED TECHNICIAN TO PROVIDE 12 TECHNICAL INSTALLATION SUPPORT FOR PANEL START UP, PROGRAM ITEM #:US1400 EDITING, TROUBLESHOOTING OF THE FIRE ALARM SYSTEM CONTROL PANEL, AND ASSISTANCE TO THE INSTALLER FOR ONE COMPLETE FINAL SYSTEM CHECKOUT IN ACCORDANCE WITH THE FIELD QUALITY CONTROL SECTION EMERGENCY BALLAST. CLEAR AL.ZAK AL.ZAK REFLECTOR OF THESE SPECIFICATIONS. 18. FIRE ALARM CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE 0-20888, 1951 AND WHITE TRIM RING. 277VAC NOTE 1 PROPER AUTHORITIES IN THIS JURISDICTION. THESE SHOP DRAWINGS SHAH L5 80 2 INCLUDE, BUT NOT LIMITED TO; BATTERY CALCULATIONS, VOLTAGE DROP BARTCO BFL281-S35 SMALL PROFILE, ADJUSTABLE FLUORESCENT STRIP WITH 2 CALCULATIONS, MANUFACTURER/MODEL NUMBER/LISTING INFORMATION FOR 52 EQUIPMENT, DEVICES AND MATERIALS. FIRE ALARM SYSTEM SYMBOL LEGEND SYMBOL DESCRIPTION ® CEILING -MOUNTED SMOKE DETECTOR CATALOG FIRE ALARM HORN/STROBE DEVICE D FIRE ALARM VISUAL DEVICE TYPE SPRINKLER SYSTEM FLOW SWITCH BY FPC WIRED BY E.C. COORDINATE WITH MANUFACTURER MECHANICAL CONTRACTOR. © SPRINKLER SYSTEM TAMPER SWITCH BY FPC WIRED BY E.C. COORDINATE WiTH `. MECHANICAL CONTRACTOR. Southfield, MI 48034 USA DUCT -TYPE SMOKE DETECTOR WITH REMOTE TEST STATION PROVIDED BY MECHANICAL 248 355 0890 CONTRACTOR, WIRED BY E.C. - INSTALLED IN DUCTWORK BY MECHANICAL mom CONTRACTOR PER CODE. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR www.ba.com & MANUFACTURER. PROVIDE CONDUIT & WIRING NECESSARY TO SHUT DOWN ❑J HVAC UNIT UPON SMOKE DETECTOR ACTIVATION. © FIRE ALARM CONTROL PANEL D MANUAL PULL STATION MOUNTED 48" AFF TO TOP. Q LANDLORD JUNCTION BOX TiE-IN FM__N_I FIRE ALARM ANNUNCIATOR TRICAL ABBREVIATIONS A------------- AMPS AC ------------ AIR CONDITIONING UNIT AFF ----------- ABOVE FINISH FLOOR AFG----------- ABOVE FINISH GRADE AHU----------- AIR HANDLING UNIT AIC------------ ASYMMETRICAL INTERRUPTING CURRENT ARCH. ---------- ARCHITECTURAL ATS ----------- AUTOMATIC TRANSFER SWITCH AWG ----------- AMERICAN WIRE GAGE BKR----------- BREAKER BLDG. ---------- BUILDING C------------- CONDUIT CAN----------- CABLE TELEVISION CCN----------- CLOSED CIRCUIT TELEVISION CH ------------ CHILLER CONTR---------- CONTRACTOR CT ------------ COOLING TOWER CU ------------ COPPER CUH----------- CABINET UNIT HEATER DE ------------ DUAL ELEMENT DN ------------ DOWN DS ------------ DISCONNECT SWITCH DWG.----------- DRAWING (E) or EXIST------ EXISTING EB ------------ ELECTRIC BASEBOARD E.C.----------- ELECTRICAL CONTRACTOR EF ------------ EXHAUST FAN EH ------------ ELECTRIC HEATER ELECT ---------- ELECTRICAL EM ------------ EMERGENCY EMT ----------- ELECTRICAL METALLIC TUBING EQ.------------ EQUAL ETR ----------- EXISTING TO REMAIN EUH----------- ELECTRIC UNIT HEATER EWC----------- ELECTRIC WATER COOLER EWH----------- ELECTRIC WATER HEATER F------------- FUSE FA ------------ FIRE ALARM FACP---------- FIRE ALARM CONTROL PANEL FC ------------ FAN COIL UNIT FLUOR---------- FLUORESCENT FPB ----------- FAN POWER BOX (VAV) F.P.C.---------- FIRE PROTECTION CONTRACTOR FS ------------ FLOW SWITCH FT. ------------ FOOT/FEET G.C.----------- GENERAL CONTRACTOR GF]------------ GROUND FAULT INTERRUPTING PROTECTION GND----------- GROUND HID ----------- HIGH INTENSITY DISCHARGE HOA ----------- HAND -OFF -AUTOMATIC HP ------------ HORSEPOWER HPS----------- HIGH PRESSURE SODIUM HVAC----------- HEATING, VENTILATION, AIR CONDITIONING IG ------------ ISOLATED GROUND INCAND.--------- INCANDESCENT JB ------------ JUNCTION BOX KCMIL---------- ONE THOUSAND CIRCULAR MILS K.E.C.---------- KVA----------- KILOVOLT AMPERE KW ------------ KILOWATT LTG ----------- LIGHTING LV ------------ LOW VOLTAGE MATV----------- MASTER ANTENNA TV MAU----------- MAKE-UP AIR UNIT MAX ----------- MAXIMUM MCB----------- MAIN CIRCUIT BREAKER MCC ----------- MOTOR CONTROL CENTER M.C.----------- MECHANICAL CONTRACTOR MECH.----------- MECHANICAL MFR ----------- MANUFACTURER MH ------------ METAL HALIDE MIN ----------- MINIMUM MLO ----------- MAIN LUGS ONLY MOD ----------- MOTOR OPERATED DAMPER MSB ----------- MAIN SWITCHBOARD MiD----------- MOUNTED NEC ----------- NATIONAL ELECTRIC CODE NF ------------ NON FUSED NFPA---------- NATIONAL FIRE PROTECTION ASSOCIATION NIC------------ NOT IN CONTRACT NL ------------ NIGHTLIGHT NTS ----------- NOT TO SCALE OCC ----------- OCCUPANCY 0 or P --------- PHASE PB ------------ PULL BOX P.C.----------- PLUMBING CONTRACTOR PNL----------- PANEL PRE ----------- POWER ROOF EXHAUSTER PVC ----------- POLYVINYL CHLORIDE RE ------------ REMOVE EXISTING RR ------------ REMOVE AND RELOCATE RTU ----------- ROOF TOP UNIT SPKR---------- SPEAKER SPST----------- SINGLE POLE SINGLE THROW TS ------------ TAMPER SWITCH TTB----------- TELEPHONE TERMINAL BOARD TV ------------ TELEVISION TYP.----------- TYPICAL UH ------------ GAS FIRED UNIT HEATER UL ------------ UNDERWRITER'S LABORATORY UON----------- UNLESS OTHERWISE NOTED UV ------------ UNIT VENTILATOR V------------- VOLTS W------------- WATTS WP ------------ WEATHERPROOF TYPE DEVICE (NEMA 313 RATED) X'FMR---------- TRANSFORMER ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION LAMPS CONDUIT WITH WIRING RUN CONCEALED IN OR ABOVE CEILING OR WALL, CATALOG OR RUN EXPOSED IN UNFINISHED AREAS. CROSS HATCHING INDICATES NUMBER H&M CATALOG OF CONDUCTORS (#12 A.W.G. - MINIMUM). PROVIDE A CODE -SIZED GROUND TYPE WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. MANUFACTURER m - INDICATES ADDITIONAL ISOLATED GROUND WIRE. DESCRIPTION CONDUIT WITH WIRING RUN CONCEALED BELOW FLOOR. CROSS HATCHING INDICATES `. NUMBER OF CONDUCTORS (#12 A.W.G. - MINUMUM). PROVIDE A CODE -SIZED Southfield, MI 48034 USA GROUND WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. 248 355 0890 CUT AND PATCH FLOOR AS REQUIRED. mom LIGHTING PANELBOARD MOUNTED 6'-6" TO TOP. SEE PANEL SCHEDULES www.ba.com AND ELECTRICAL ONE -UNE DIAGRAM. ❑J SAFETY SWITCH - TYPE AND RATING AS SHOWN ON PLANS AP SECURITY SYSTEM CONTACT 1 20A - 120V/277V SINGLE POLE TOGGLE SWITCH MOUNTED 48" AFF, UNLESS SPECIALTY LIGHTING NOTED OTHERWISE �WHRE INDICATED - SUBSCRIPT "3" DENOTES 3 WAY SWITCH RECESSED 39W METAL HALIDE DOWNUGHT WITH AND SUBSCRIPT "M DENOTES MANUAL MOTOR STARTER) 107 20A -2P -3W -125V GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 18" A.F.F., t1� U.O.N. 20A -2P -3W -125V GROUNDING TYPE DOUBLE DUPLEX RECEPTACLE MOUNTED ITEM #:91179 18" A.F.F. U.O.N. G 20A -2P -3W -125V ISOLATED GROUND TYPE DUPLEX RECEPTACLE MOUNTED Z 18" A.F.F. U.O.N. G 20A -2P -3W -125V ISOLATED GROUND TYPE DOUBLE DUPLEX RECEPTACLE MOUNTED 18" A.F.F. U.O.N. BEAM SPREAD, AND WHITE TRIM RING. 277VAC. 20A -2P -3W -125V GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE MOUNTED 48" A.F.F., UNLESS NOTED OTHERWISE. 20A -2P -3W -125V SPLIT (2 -CIRCUIT) GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED AT 18" A.F.F., UNLESS NOTED OTHERWISE. ONE CIRCUIT SHALL FEED F�-- TOP HALF AND ONE CIRCUIT SHALL FEED BOTTOM HALF OF RECEPTACLE. Qa JUNCTION BOX - SIZE AS REQUIRED BY N.E.C. XX INDICATES CODED NOTE El DOORBELL PUSH BUTTON MTD. 48" A.F.F. Q DOORBELL MTD. 84" A.F.F. $M MANUAL MOTOR STARTER WITH SIZED OVERLOAD PROTECTION. ® LIGHTING CONTROL TIME CLOCK $K LIGHTING CONTROL OVERRIDE KEY SWITCH 0 SPEAKER, FLUSH MOUNTED U.O.N. P CYLINDRICAL ANODIZED REFLECTOR AND FLOOD ADJACENT TO SYMBOL INDICATES PENDANT MOUNTED 7 COMMUNICATIONS OUTLET MOUNTED 18" AT A.F.F. U.O.N. 5(0) PROVIDE CONDUIT SIZED PER SPECIFICATION'S FILL REQUIREMENTS (3/4 MINIMUM) TO DATA RACK IN LAN ROOM WITH CABLING PER BEAM SPREAD, AND BLACK TRIM RING. 277VAC. SPECIFICATIONS. 'W ADJACENT TO SYMBOL INDICATES WALL MOUNTED AT 54" A.F.F. REFER TO RESPONSIBILITY SCHEDULE SECTION 16740 LETTERS) ADJACENT TO SYMBOL DEFINES THE USE OF THE OUTLET: D - DATA - NUMBER ADJACENT TO SYMBOL DEFINES THE QUANTITY OF CABLES SM,BM SILVER OR BRONZE MIRROR THE FULL HEIGHT AND WIDTH OF THE COLUMN FROM L--- j FLOOR TO CEILING. IF A BASEBOARD IS PRESENT, THEN MIRROR HEIGHT IS FROM 1 THE BASEBOARD TO CEILING. FURNISHED AND INSTALLED BY OTHERS. }- MOTORIZED DAMPER WIRED BY ELECTRICL CONTRACTOR. RECESSED 10OW METAL HALIDE DOWNUGHT WITH COORDINATE WiTH MECHANICAL. CONTRACTOR. 2 DOME CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY E.C.. FIXED CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY E.C.. 1. FINAL CONNECTIONS TO LIGHT FIXTURES SHALL BE MADE WITH GREENFIELD FLEXIBLE CONDUIT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 6'-0". 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURE LAY -OUT. CONTRACTORS TO COORDINATE LOCATIONS OF LIGHTING, SPEAKERS, AIR DIFFUSERS, GRILLES, SPRINKLER HEADS & THE LIKE, WITH REFLECTED CEILING LAY -OUTS AS REQUIRED & DIRECTED BY THE ARCHITECT. 3. ALL DEVICES, EQUIPMENT, FIXTURES, & THE LIKE, MUST BE GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL/ ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM SHAH ALSO BE MAINTAINED. 4. REFER TO MECHANICAL AND PLUMBING PLANS FOR EXACT LOCATION OF MECHANICAL AND PLUMBING EQUIPMENT. COORDINATE LOCATION OF DISCONNECT SWITCH ASSOCIATED WITH EACH PIECE OF EQUIPMENT WITH MECHANICAL CONTRACTOR AND INSTALL IN ACCORDANCE WITH THE NEC. 5. REFER TO DIVISION 15 (22 & 23) SPECIFICATIONS, HVAC PLANS & PLUMBING PLANS FOR ADDITIONAL ELECTRICAL WORK REQUIREMENTS & COORDINATION. 6. ALL RECEPTACLES SHOWN BACK-TO-BACK IN WALLS SHAH BE SEPARATED HORIZONTALLY BY 8" MINIMUM. 7. WHERE OPEN WIRING METHODS FOR LOW VOLTAGE SYSTEMS ARE PERMITTED BY THE CONTRACT DOCUMENTS AND LOCAL AUTHORITY, THE CONDUCTOR INSULATION MUST BE PLENUM RATED. 8. BRANCH CIRCUIT CONDUCTOR SIZES (& CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHAH BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL & THE LOADS DO NOT EXCEED A LIMIT OF 3%. LIGHTING FIXTURE SCHEDULE PE: 0051703 LOAD LAMPS ® schematic des. CATALOG ❑ design dev. H&M CATALOG APPROXIMATE TYPE (VA) MANUFACTURER NUMBER DESCRIPTION NUMBER FIXTURE COUNT :z Southfield, MI 48034 USA ! 248 355 0890 No. TYPE ° ~` ` °2we ilk h. . www.ba.com JGA Pr j #: 1-209-057 AP 46 1 CDM35/T6/830 SPECIALTY LIGHTING - RECESSED 39W METAL HALIDE DOWNUGHT WITH 91179 107 t1� ITEM #:91179 CYLINDRICAL ANODIZED REFLECTOR AND FLOOD w U Z LL_ Q 0zz�o ACCESSORIES: BEAM SPREAD, AND WHITE TRIM RING. 277VAC. LU z OL 0) F�-- NOTE 1 AP 46 1 CDM35/T6/830 SPECIALTY LIGHTING - RECESSED 39W METAL HALIDE DOWNUGHT WITH B91179 216 ITEM #:B91179 CYLINDRICAL ANODIZED REFLECTOR AND FLOOD ACCESSORIES: BEAM SPREAD, AND BLACK TRIM RING. 277VAC. - NOTE_ 1 AP1 130 1 CDM100/T6/830 SPECIALTY LIGHTING - RECESSED 10OW METAL HALIDE DOWNUGHT WITH 91122 2 ITEM #:91122 CYLINDRICAL ANODIZED REFLECTOR AND FLOOD ACCESSORIES: BEAM SPREAD, AND WHITE TRIM RING. 277VAC. - NOTE 1 B2 92 2 CDM35/T4/830 SPECIALTY LIGHTING - 2 -LAMP 39W METAL HALIDE ADJUSTABLE ACCENT 911601 39 ITEM 1:911601 FIXTURE WITH ELECTRONIC BALLAST. 277VAC ACCESSORIES: WHITE FINISH. NOTE 1 C 44 1 PLT42/30/4P/ALTO SPECIALTY LIGHTING 6VF142TE4-EM/6VFSCL 6" RECESSED 42W COMPACT FLUORESCENT OPEN US1400ES 61 ITEM #:US1400ES DOWNUGHT WITH INTEGRAL EMERGENCY BATTERY PACK ACCESSORIES: AND INTEGRAL TEST SWITCH CLEAR ALZAK REFLECTOR 0-20888, 1951 AND WHITE TRIM RING. 277VAG NOTE 1 E 23 1 CDM20/i4/830 SPECIALTY LIGHTING - 4.5" RECESSED 20W METAL HALIDE DOWNLIGHT WiTH 91121 14 ITEM #:91121 SEMI -DIFFUSE ALUMINUM HA.MMERTONE SUNRISE OPTIC ACCESSORIES: REFLECTOR, CLEAR GLASS LENS, AND WHiTE TRIM - RING. 277VAC. NOTE 1 G 64 2 F32T8/830/ALTO DAY-BRiTE T232-UNV-1/2-E8101/ 4'-0" LONG CHAIN MOUNTED ESCENT FIXTURE. N/A VERIFY ON LIGHTING FKR-126, WITH LAMP WITH ELECTRONIC BALLAST. 277VAC. NOTE 3 PLANS (ADD 15" AS REQUIRED) 0 H 96 3 F32T8/830/ALTO DAY-BRiTE 2TG8332-21-UNV- 2'x4' RECESSED FLUORESECNT FIXTURE WITH WITH N/A VERIFY ON LIGHTING 1/3-EB101 .125" ARCYLIC PRISMATIC LENS, FLAT STEEL DOOR PLANS (ADD "E5" AS REQUIRED) AND ELECTRONIC BALLAST. 277VAC. NOTE 3 J 44 1 PLT42/30/4P/ALTO SPECIALTY LIGHTING 6VF142TE4-6VFSCL 6" RECESSED 42W COMPACT FLUORESCENT OPEN US1400 12 ITEM #:US1400 DOWNUGHT SIMILAR TO TYPE "C" EXCEPT NO ACCESSORIES: EMERGENCY BALLAST. CLEAR AL.ZAK AL.ZAK REFLECTOR 0-20888, 1951 AND WHITE TRIM RING. 277VAC NOTE 1 L5 80 2 F35T5/830 BARTCO BFL281-S35 SMALL PROFILE, ADJUSTABLE FLUORESCENT STRIP WITH 2 N/A 52 LAMPS STAGGERED, INTEGRAL T5 ELECTRONIC BALLAST, FIXTURE SHALL BE 100-7/8" TO 112-7/8" IN LENGTH, OVERLAPING 3" TO 7". 120V. NOTE 5. L4 64 2 F28T5/830 BARTCO BFL281-S28 SMALL PROFILE, ADJUSTABLE FLUORESCENT STRIP WITH 2 N/A 7 LAMPS STAGGERED, INTEGRAL T5 ELECTRONIC BALLAST. FIXTURE SHALL BE 76" TO 88" IN LENGTH, OVERLAPING 3" TO 7". 120V. NOTE 5. L3 56 2 F21T5/830 BARTCO BFL281-S21 SMALL. PROFILE, ADJUSTABLE FLUORESCENT STRIP WITH 2 N/A 16 LAMPS STAGGERED, INTEGRAL T5 ELECTRONIC BALLAST. FIXTURE SHALL BE 52-1/2" TO 64-1/2" IN LENGTH, OVERLAPING 3" TO 7". 120V. NOTE 5. L2 40 2 F14T5/830 BARTCO BFL281-S14 SMALL PROFILE, ADJUSTABLE FLUORESCENT STRIP WITH 2 N/A 2 LAMPS STAGGERED, INTEGRAL T5 ELECTRONIC BALLAST. FIXTURE SHALL BE 32-3/8" TO 41-7/8" IN LENGTH, OVERLAPING 3" TO 7". 120V. NOTE_ 5. L4A 32 1 F28T5/830 BARTCO BFL281-28 SMALL PROFILE FLUORESCENT STRIP WITH INTEGRAL 81349 103 T5 ELECTRONIC BALLAST. FIXTURE IS 46 -1/16 - IN LENGTH. 120V. NOTE 5. L2A 20 1 F14T5/830 BARTCO BFL281-14 SMALL PROFILE FLUORESCENT STRIP WiTH INTEGRAL 81347 35 T5 ELECTRONIC BALLAST. FIXTURE IS 22-1/2" IN LENGTH. 120V. NOTE 5. T SEE T1 FOR TRACK HEAD SPECIALTY LIGHTING T42 RECESSED 3 -CIRCUIT 142' STYLE RECESSED 3 -CIRCUIT LIGHT TRACK US17B, US17 1658' INFORMATION WITH WHITE FINISH AND ALL RELATED ACCESSORIES, FEEDS, CONNECTORS, ETC. INCLUDING RECESSED JACKET ASSEMBLY AND ITS ACCESSORIES. 120V. NOTE 1 T1 45 1 CDM35/T6/830 SPECIALTY LIGHTING 39E-3GRAY ITEM 39W METAL HALIDE TRACK HEAD. 77592 VERIFY WITH H&M #:91006104 120V. NOTES 1 & 2 PROJECT MANAGER ACCESSORIES: 0-64361 T2 45 1 CDM35/T6/830 SPECIALTY LIGHTING 39E-3GRAY ITEM 39W METAL HALIDE TRACK HEAD. 77597 VERIFY WITH H&M #:91006104 120V. NOTES 1 & 2 PROJECT MANAGER ACCESSORIES: 0-64361 D(1 5 - WITH UNiT UTHONIA LRP -X -RC -X-120/277- LE.D. EDGE -LIT EXiT SIGN WITH STENCIL FACE, N/A VERIFY ON LIGHTING EL N -X RED LETTERS, CLEAR FACE, BRUSHED ALUMINUM PLANS HOUSING, UNIVERSAL MOUNTING AND EMERGENCY BATTERY PACK SINGLE OR DOUBLE FACE AND ARROWS AS INDICATED ON PLANS. 120/277V. EX2 5 - WiTH UNIT UTHONIA LQMSW3R120/277 LE.D. EXIT SIGN WiTH STENCIL FACE, RED LETTERS, N/A VERIFY ON LIGHTING WHITE POLYCARBONATE FACE AND HOUSING, PLANS UNIVERSAL MOUNTING AND EMERGENCY BATTERY PACK SINGLE OR DOUBLE FACE AND ARROWS AS INDICATED ON PLANS. 120/277V. NOTE 3. EM 70 - 35W MR16 UTHONIA VEL1270 12V ADJUSTABLE MR16 35W CONCEALED EMERGENCY N/A VERIFY ON LIGHTING WITH UNiT (LAMP #H3512) FIXTURE W/ WHITE FINISH. FINISH SHAH BE FIELD PLANS PAINTED TO MATCH CEILING COLOR. STANDARD SELF- DIAGNOSTIC. 120/277VAC. NOTE 3. 9. REGARDLESS OF THE TEMPERATURE RATING OF THE CONDUCTOR INSULATION, ALL CONDUCTOR AMPACITY RATINGS FOR THIS PROJECT SHAH BE DETERMINED FROM THE 75'C CONDUCTOR TEMPERATURE RATINGS INDICATED IN THE NEC TABLES. WHERE EQUIPMENT OR DEVICES ARE PROVIDED WITH TERMINALS/LUGS RATED FOR 60'C, THE AMPACITY RATING OF THE 75°C CONDUCTOR SHAH BE LIMITED TO ITS ASSOCIATED 60`C RATING AS INDICATED IN THE NEC TABLES. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INCREASE THE CONDUCTORS AND CONDUIT SIZE AS REQUIRED. 10. CIRCUITS MAY BE MULTI-PLEXED IN A CONDUIT PROVIDED THE AMPACITY OF THE CONDUCTORS ARE PROPERLY DERATED & CONDUIT IS SIZED PER CODE. UNDER NO CIRCUMSTANCES SHAH MORE THAN SIX (6) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. REFERENCE NEC ARTICLE AND TABLE 310.15(B)(2)(a). 11. ALL CONDUITS SHALL CONTAIN A GROUND CONDUCTOR SIZED PER NEC TABLE #250.122. IN ADDITION, WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED, A SEPARATE GROUND CONDUCTOR WITH GREEN INSULATION SHAH BE RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE SHALL THE SYSTEM GROUND (CONDUCTOR & ASSOCIATED OUTLET BOXES, CONDUIT & BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (CONDUCTOR & DEVICE). WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE GROUND CONDUCTOR SIZE SHAH BE INCREASED PROPORTIONATELY (ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY NEC TABLE #250.122. 12. EXACT WIRING REQUIREMENTS FOR ALL HVAC, PLUMBING AND OWNER FURNISHED EQUIPMENT SHALE BE VERIFIED WITH THE MANUFACTURER OF THE FURNISHED EQUIPMENT PRIOR TO ROUGH -IN. 13. THE ELECTRICAL CONTRACTOR SHAH FURNISH ALL ACCESS PANELS, AS REQUIRED FOR SERVICING AND TESTING, FOR EQUIPMENT AND/OR DEVICES FURNISHED UNDER HIS CONTRACT. THE GENERAL CONTRACTOR SHAH INSTALL ACCESS PANELS. THE ELECTRICAL CONTRACTOR SHAH COORDINATE THE SIZE AND LOCATION OF EACH ACCESS PANEL WITH THE ARCHITECT AND GENERAL CONTRACTOR PRIOR TO ROUGH -IN. - __ t >�= ►! 1. FIXTURE AND LAMPS FURNISHED BY H & M, AND INSTALLED AND WIRED BY E.C. (TYPES AP,AP1,B2,C,E,J,T1,T2) 2. VERIFY INSTALLATION LOCATION WITH H & M REP. THE E.C. SHAH INCLUDE IN HIS BID, THE LABOR COST TO INSTALL APPROX. 400 TRACK FIXTURES AND LAMPS. 3. LIGHT FIXTURES, EXIT SIGNS, AND LAMP(S) FURNISHED, INSTALLED AND WIRED BY E.C.. ACCEPTABLE ALTERNATE MANUFACTURERS SHAH BE: TYPE G,H: UTHONIA, METALUX, DAY-BRiTE, HUBBELL TYPE EX1, EX2, EM: SURELITES, EMERGI-LTTE, LiTHONIA 4. SHADED SALES LIGHT FIXTURES AND HALF -SHADED NON -SALES LIGHT FIXTURES ON THE E2 SERIES DRAWINGS SHALL BE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. 5. FIXTURE TYPE L5, L4, L3, L4A, L2, AND L2A FURNISHED, INSTALLED AND WIRED BY E.C. E.C. MUST ORDER THROUGH SPECIALTY LIGHTING. CONTACT: SUE GRAHAM SPECIALTY LIGHTING 1-860-767-0110 35 INDUSTRIAL PARK ROAD #10 CENTERBROOK CT, 06409 ALL WIRiN"HIALL BE IN CONDUIT OR JIM FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. ALLOWED. THIS APPLIES TO ALL ELECTRICAL SYSTEMS, INCLUDING POWER, LIGHTING, CONTROL, HVAC, SECURITY, DATA, PHONE, ETC. LOCATION OF NAMEPLATE FOR SURFACE MOUNTED PANELS. FOR FLUSH -MOUNTED PANELS, INSTALL NAMEPLATE BEHIND DOOR. ENGRAVED LAMACOID, 5/32" LETTERS, SECURE TO PANEL BOARD COVER WITH ADHESIVE TYPE FASTENER. "....,, 'HENT DESIGNATION TQM. NAMEPLATES ARE REQUIRED ON ALL SWITCHBOARDS, DISTRIBUTION PANELS, PANEL BOARDS, STARTERS, DISCONNECT SWITCHES, RELAYS AND JUNCTION BOXES GREATER THAN 4 11/16" SQUARE. ALSO PROVIDE NAMEPLATES ON BRANCH SWITCHES OF SWITCHBOARDS AND DISTRIBUTION PANELS. STANDARD COLORS: 1. NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2. EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING 3. IN ADDITION TO THE FUNCTION NAMEPLATE, PROVIDE NAMEPLATES IDENTIFYING ALL "MAIN SERVICE NAMEPLATE DISCONNECTS" - RED BACKGROUND - WHITE LETTERING NAMEPLATE DETAIL NO SCALE -1� ®® l THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: V P rill°7 JEFFERY D. MTTERKO PE: 0051703 ❑ programming EB: 0007857 ® schematic des. Expires: 2/28/11 ❑ design dev. Consultants: ❑ bidding RIFTAL TAW ® permits JDA vc LU 29110 Inkster Road M landlord prelim. Suite 200 :z Southfield, MI 48034 USA ! 248 355 0890 L 248 355 0895 Fax ° ~` ` °2we ilk h. . www.ba.com JGA Pr j #: 1-209-057 DRAWINGS ISSUED FOR: ❑ programming TE3A ® schematic des. 02.Oq.Oq ❑ design dev. JDM ❑ bidding ® permits 03.12.Oq LU M landlord prelim. CS :z 0 - REVISIONS: co L � w o � :Z N d V m }- t1� w V (3 w U Z LL_ Q 0zz�o J LU z OL 0) F�-- DRAWINGS ISSUED FOR: ❑ programming TE3A ® schematic des. 02.Oq.Oq ❑ design dev. JDM ❑ bidding ® permits 03.12.Oq ❑ construction M landlord prelim. 02.0q.0q 0 landlord final 02.27.0q REVISIONS: AiADDENDUM #1 03.12.Oq Prj. no. 8-209-012 Drawn TE3A Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: EL.ECTRICAI. LEGENDS AND SCHEDULES Sheet no. ANN= Aft t C) 9 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright Uc 2009 KEN NISCH, AIA All rights reserved Certification: DRAWINGS ISSUED Q ❑ programming IN schematic des. 02.0q,0q ❑ design dev. ❑ bidding tt IJ permits LL- ❑ construction LU 9landlord prelim. 02.Oq.Oq �. U�7 REVISIONS: co L � W O � U m �wQg ,-QLt- Lu LU U O w � c o LQ J Q L t— O J N < A N DRAWINGS ISSUED FOR: ❑ programming IN schematic des. 02.0q,0q ❑ design dev. ❑ bidding IJ permits 03.12.Oq ❑ construction 9landlord prelim. 02.Oq.Oq M landlord final 02.27.0q REVISIONS: 0 ADDENDUM #1 03.12,Oq Prj. no. 8-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: PANEL SCHEDULES Sheet no. 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 3550895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: JEFFERY G. MITERKO PE: 0051703 ❑ programming EB: 0007857 11 schematic des. Expires: 2/28/11 ❑ design dev. Consultants: O bidding RETAIL DEM CONMLTMT ® permits JOA me ❑ construction 29110 Inkster Road IN landlord prelim. Suite 200 ® landlord final Southfield, MI 48034 USA 1 248 355 0890 Lt 248 355 0895 Fax � wevw.jga.com JGA Pr j #: 1-209-057 DRAWINGS ISSUED a ❑ programming 11 schematic des. o ❑ design dev. O bidding 4 ® permits 03.12.Oq ❑ construction LUa IN landlord prelim. 02.Oq.Oq ® landlord final O REVISIONS: co Lt %& u.f � fi M V_ LUw�LLI V W_ E v z LL_0 0 O :K Ll 41 N ~ L1K O O g a M DRAWINGS ISSUED FOR: ❑ programming 11 schematic des. 02.Oq.Oq ❑ design dev. O bidding ® permits 03.12.Oq ❑ construction IN landlord prelim. 02.Oq.Oq ® landlord final 02.27.0q REVISIONS: 0 ADDENDUM #1 03.12.Oq Prj. no.. 8-209-012 Drawn TSA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: ONE -DINE Sheet no. tou 0 E Q, N N N F- W O O N : 0 0 0 n a V)) ul ar U (V W 0 O O I O N E Z a r 1 FIXTURE TYPE "G" (TYP) j FIXTURE TYPE "H" (TYP) A 64 NA— ►' FIXTURE TYPE "AP1" 1 0 ®® L GENERAL LIGHTING PLAN IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. FIXTURE TYPE "E" (TYP) ALL WIRING SHALL RE IN CON®UIT OR JIM FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. GENERALNOTES 1. REFER TO DRAWING(@Dl FOR SCHEDULES AND DETAILS OF THE LIGHTING CIRCUITS CONTROLLED BY THE SQUARE D "POWERLINK" LIGHTING CONTROL SYSTEM.A' 2. EMERGENCY LIGHTS AND EXIT SIGN BATTERIES IN THE SALES AREA SHALL BE WIRED TO THE NON—CONTROLLED HALF OF THE REQUIRED "POWERLINK" EMERGENCY LIGHTING CIRCUIT BREAKER(S). REFER TO PANEL SCHEDULES ON DWG. E0.2. 0 1 3. ONLY THE "NORMAL" BALLASTS OF TYPE "G", &PH" ES LOCATED IN THE BACK—OF—HOUSE SHALL1 VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE EMERGENCY BALLASTS, AND EXIT SIGN BATfERI BACK—OF— HOUSE SHALL BE WIRED TO THE NON—CONTROLLED HALF OF THE SQUARE—D "POWERLINK" EMERGENCY LIGHTING CIRCUIT BREAKER(S). REFER TO PANEL SCHEDULES ON DRAWING E0.2 4. ALL NIGHT LIGHTS (NL) SHALL BE WIRED TO THE NON—CONTROLLED HALF OF THE SQUARE—D "POWERLINK" EMERGENCY LIGHTING CIRCUIT BREAKER(S) AHEAD OF ALL LOCAL SWITCHING AND CONTROLS. 5. HALF—SHADED NON—SALES LIGHTING FIXTURES AND SHADED RESTROOM LIGHTING FIXTURES ARE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: JEFFERY D. MITERKO PE: 0051703 E13:0007857 Expires: 2/28/11 Consultants: Q ❑ programming REIIAL DESM CONSULTANT ® schematic des. O LU JGA me ❑ bidding 29110 Inkster Road ® permits 03.12.0q Suite 200 LU ® landlord prelim. Sa Affeld, MI 48034 USA landlord final < 248 355 0890 LU 248 355 0895 Fax avrah 0 2M X& Iia U-1 N rgib,aa�wd MrNMl.J9axo n LU JGA Pr j #: 1-209-057 LU kJ DRAWINGS ISSUED Q ❑ programming ® schematic des. O LU ❑ design dev. ❑ bidding ® permits 03.12.0q ❑ construction LU ® landlord prelim. Qi landlord final < REVISIONS: LU �9 U-1 N LU LU kJ _ U m H Q H U_ LU LLA U O w n/ c o n/ ® z J 41 O'er O N mai —� L i� EL N (S) DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding ® permits 03.12.0q ❑ construction ® landlord prelim. 02.Oq.Oq landlord final 02.27,09 REVISIONS: 0 ADDENDUM #1 03.12.09 Prj. no. 8-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: GENERAL LIGHTING PLAN Sheet no. E'AN& O -- EXTERIOR® E6RF55 CORRIDOR EI EGTRIGAL i - - i �p- / U n L_________--------------� I I -C -I ci3 50. FT. =-- LP1,-1,35 LPl 13,15,17 I- - � JAN. MEN'S � '-_------� �----------� i CLOSET TOILET WOMEN'S t� i - 45 �C�. 123 50. FT. --TOILET. �� T(54') AA r__ r_r rrr r_r A _rr r_ r------- 7T r _ / �� /�I Zc- �rr-r rrrrrrrr�rmw 4-- -®- -�- -- -.-------rr-------- r rrrrr-�rrrrrQrr e�-wwrmt�wrr-r..�- r�s -9- rra.�rrr �� r 13q �G2. FT. i T(T5p); -'�'I- i 1(40') T(zo,) i 1(40')*T(40') r LP1-19,21,23 i LP1-25,27,29 i LP1-31,33,35 ; LPl-43,45,47 ; 5ALE5 FLOOR r� ® �q 5Q. El. LAN. i i h i r I 1 ROOM �/ I rrrr ; LP1-7,911 i 'fin Q -I ,�F -' - J ; � � LP1-37,3 ,41 LOUNGEIs 160 5G2. FT. I nn i '4P I � I 1116r rrrrrmrr&-=. mm�-wm--®-r----r-r®---r-_4.r----�---a--------m----mmm I mmmmammm_r_ I �C18'�_ -'_I®_ ------ F 1 i A MIN Of=I E i T 3' 1(63') -- - - ° ®P -r i 142 5Q. FT.- J i i LP3-2,4 6 I --� D � STOGrRooM ' � i � _ I � � � � I I � - �\ e I 612 50. FT. 1 `. _ T(61) - i - - m T(6=) 5ALE5 F=LOOR ' T(42')�- �T(42') T(42')� i DECO ROOM L 135 5a. FL. ' ' LP1-73,75, 7 ' ° P1-67,69,71 ° I Q , T(42) � � � 8 � 0 5 LE aFLO R ; � I i T , _111t X /n LP1-68,70,7 Go . - ____. ♦ ( i , �r rr arrsm�-rrrl-rmr-+�■rrrrmB rm� ® ° I � LP1- 61,63,65Lj '7 i i T(4') 1(15') ® I� T(27') 0r rrggerArrr�ra+Wrrr�r�lmrr�-tri■ m.l , �'/ ; ; ------ ;T(17) T(4) I 5ALE5 F©Loon O - T(4) i '� T(10'): i -- I i I D T(7) r , ° r , �r r�r�r.rl�m.�+rr> r�--- . .� / L�1--62,64,66 , ° ; �.mmww .�.-----0---aarra r r..wr�.rr ■d T(2( { 1TTIN6 1 ' 1 T(14) 1(14) T(14 ) till i ROOMS � I I ° � I r r ® � LPl-49,51,53 LP1-56,58,60 �\ i ID i i ,�' TYPICAL 2 T(10) (TYPICAL) ' - ■ wm- -6- ---ir --- - i ® T(7')' i i' ; i = ' -- =- �- ---- ------ ----- ---- _L5 L5 LPl-50,52,54 LP1-44,46,48 L4 �_--- --- -�--- ----r ; ( ,) T(40') a T(38') T(4,) e ; T 15 ; 1 r .ea�..rrrr -mr®- -----r-�--- -----& r®r� �rr wrr�hi■-rr rr6r_r r- ---- ®-----�-----'�------& r_ .gym ' i ; ; I �° ; r G7 -- - T(3') A Cp/ v v1® T(�) i 1 r LP1-55,57,59 , 1 ,� I 1 rrrrr - rrrrr a °� T(15') 1(42') 1(13') i 1(40); LP1-38,40,42 I L5 i '� r i i° ' i Fill 1 _ _° -� �} - - - - - - - - - - -;— - -i - - , - ;- - - i- - - I - - , - - 1- - E} - —� - - - - - - e LP3-1 T(42')- -r-- ------ a—m�4------ ®"'�---m'�------ a------ --a--'® i ° - ° 1 1---- I 9 � i I ° � LP1-8,10,12 sI _� , 4T(20') lllrlllT 20' ------J T 10' r_-fir-rr T 30'rrrrr� rrrr.�.rmmrr-r-mr... rmm mma (23') �g [_ 4 `p ( ) ( ) ( ) �r --r ------- -- - m�amrr W l Iv LP1-2,4,6 LU F—i i I I T(5'):'i ' ; I i FITTING 7 i T(24') i Cor-- I e ;1(29') i ROOMS / LP1-32,34, 6 ,� a, , I --------------------------------- --.mmq�m-mmm m---a�,mm-ab am v r e T(6' "' T(6') ° i i T 13' i1 T(27') ; o ) ° 5ALE5 FLOOR 1 ® r p �; (_ a_rar®dr-r_r�u--__-_ ; LP,—,4J16,V LP3-3 ; 1(24') O O r LP 1-21.28,30 r - — T(12') LP1-20,22,24 T(12') ,1 ® 1 I -r rr.�a-rrrrr �TTo r 1 ! 1(42') T 11' 2') ` 1(11')m 5ALE5 FLOOR _ -wmmmam-___a�, ____�-rr_r� a_a>�raaaa9-ra__,-a-_-�i I ° I (23) r 1 e -IID ID all 01 1 , I L5 j ' I L5 ; ; mm mmrmr�---- 5ALE5 FLOOR ,�°-- .�.---rr�--�' =k ! ;ID 0L-- ----- ------ ------ T(�oa�-a _-_� T( ') I ;T(12 )- a ; T(3') T(32ar _ - + * T(4')�, ra- L4 T 40' _ _()L4 i tJ FIXTURE TYPE ' 'T1i i T(17') i I i 1 _ _ _ _ _ _ _ _ _ (TYPICAL SALE FLOOR) 15 L5 L5 L5 ---- - LP3-8,10,12 0 LP3=14;16-18_ _ _ I — _ t T(5 - - - - - T(1-7-)- - - - T�T7 }- - - - �- - - - - x(17 } - - - T�14 } - - - - - - T__ ppwrrrr� -® -- / f� pmp® rrrarr rrrrrrr rrgir rrrr-�-r rrrrrrrrr qpm-6`iF-----a---p----�r ID 1 FIXTURE TYPE 'T',"T2' i (TYPICAL SHOW WINDOW) -- MA�L CONCOURSE 1/810=11-0" ME: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. A FOR: 0 programming N schematic des. 02.Oq.Oq 0 design dev. 0 bidding At ® permits 03.12.Oq 0 construction U ® landlord prelim. W N landlord final 0) Uj co LLI CODED NOTES N V O1 E.C. SHALL CONNECT THE THREE -CIRCUIT TRACK FIXTURE TO THE u m THREE CIRCUIT BREAKERS INDICATED. IN NO CASE SHALL THREE ® LU 20A -1P BRANCH CIRCUITS SUPPLY MORE THAN 72 L.F. OF THREE -CIRCUIT TRACK (24 FEET OF TRACK PER CIRCUIT). (TYPICAL OF ALL TRACK LIGHTING ON THIS PLAN.) TRACK HEADS O W SHALL BE DIVIDED EQUALLY AMONG THE THREE CIRCUITS. LU :z U to O „ INDICATES AN ELECTRICAL BREAK IN TRACK OR COVE LIGHTING CIRCUIT. (TYPICAL) _j Z:;;� X — 41 :K O O < a c(v 0 ALL WIRING SHALL RE IN GONQUIT OR FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. l7� THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FLT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road(330) 659-6688 Ph. Richfield, Ohio 44286 MO 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: DRAWINGS ISSUED FOR: 0 programming N schematic des. 02.Oq.Oq 0 design dev. 0 bidding At ® permits 03.12.Oq 0 construction U ® landlord prelim. W N landlord final 0) REVISIONS: co LLI N V u m � ® LU Q Q W U O W g ® LU :z U to < _j Z:;;� X — 41 :K O O < a c(v � H DRAWINGS ISSUED FOR: 0 programming N schematic des. 02.Oq.Oq 0 design dev. 0 bidding ® permits 03.12.Oq 0 construction ® landlord prelim. 02.0q.0q N landlord final 02.27.0q REVISIONS: Prj. no. 8-209-012 Drawn TBA Checked JDN Approved JDN Do not scale this print. Use figured dimensions only. Drawing title: TRACK/COVE FIGHTING PLAN Sheet no. t2*2 O PROVIDE A RECESSED JUNCTION BOX WITH A LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT WHIP FROM THE JUNCTION BOX TO THE TYPE "L" STRIP FIXTURES MOUNTED IN THE WALL POP OUT COVE. COORDINATE THE JUNCTION BOX LOCATION IN THE FIELD. JUNCTION BOX SHALL BE LOCATED BEHIND THE POP OUT WALL, HIDDEN FROM VIEW. SEE BELOW FOR FIXTURE COUNTS AT POP OUT WALLS. REFER TO ARCHITECTURAL PLANS FOR STAGGERED FIXTURE PLACEMENT WITHIN THE WALL POP OUT COVE. ALL WIRING SHALL BE CONCEALED. WALL 1.2.3.4.5.13 — �'—Z" WALL _10,11.14 — 16' -5 - LENGTH: (1)TYPE L3, (1)TYPE L2A LENGTH: (2)TYPE L.5 TOP AND BOTTOM TOP AND BOTTOM WALL 6,7 — 20'-6" WALL 12 — 24'-7" LENGTH: (2)TYPE L.5, (1)TYPE L3 LENGTH: (3)TYPE L5 TOP AND BOTTOM TOP AND BOTTOM WALL 8.9 — 14'-4" WALL 15 — 4'-1" LENGTH: (1)TYPE L5, (1)TYPE L4 LENGTH: (1)TYPE L2, (1)TYPE L2A TOP AND BOTTOM TOP AND BOTTOM O2 REFER TO TYPICAL CASH WRAP ELEVATION ON DWG. E4.1 AND ENLARGED PLAN THIS SHEET. O3 REFER TO ENLARGED PLAN OF THIS AREA ON DWG. E4.1. ® MOUNT RECEPTACLE IN FITTING ROOM CORRIDOR AT 12" A.F.F. O JUNCTION BOX FURNISHED WITH MIRROR LOCATED AT TOP OF MIRROR ASSEMBLY (TYPICAL). VERIFY MIRROR LOCATIONS WITH ARCHITECTURAL PLANS PRIOR TO ROUGH—IN. �1 POWER PLAN �2 L*'�4i O RUN NDUIT TOP OF TO WALL, AND SEN IN 15 AND INSTALL A 20A. PST FOR SIGNAGE ER ABOVE THEAND 22 DATA (2) 2EVICET 5E CABLE ABOVE ACCESS PANEL IN CEILING FOR FUTURE ❑ design dev. UNC. BOXGTO MIRRORING J NGROOM BOX. CONDUION WALLFROMM MIRRORT SHALL BE RUN ❑ bidding CEILING. COORDINATE WITH &MISH FOR THELLOCATON, MOUNTING HEIGHTITCH QUANTITY OF N permits TRAFFIICOCOUNTING LU CONTINUOUS FROM MIRROR TO MIRROR WITHOUT INTERRUPTION BETWEEN MIRRORS (TYPICAL). ® landlord prelim. SIGN(S) AND FURNISH AND INSTALL ALL POWER, CONDUIT, WIRING, SWITCHES INTERCONNECTIONS, ® landlord final Southfleld, MI 48034 USA REVISIONS: 248 355 0890 ETC., AS REQUIRED. PROVIDE CONTROL OF SIGNAGE AS INDICATED ELSEWHERE ON CONSTRUCTION 23 REFER TO WALL ELEVATIONS AND ENLARGED PLAN OF THIS AREA ON DWG. E4.1. �7 DUPLEX OUTLET FLUSH MOUNTED IN CEILING AT DISPLAY WINDOW. DOCUMENTS. Q U 24 QUAD I.G. OUTLETS AND DATA JACKS MOUNTED 36" AFF IN DECO ROOM. VERIFY EXACT LOCATION ® DUPLEX RECEPTACLE IN FLUSH FLOOR BOX IN RAISED PLATFORM. SEE SPECIFICATIONS FOR 16 ACCESS PANEL IN CEILING FOR ACCESS TO ELECTRICAL EQUIPMENT. COORDINATE WITH G.C. LU IN ROOM WITH H&M REP. ON SITE PRIOR TO ROUGH—IN. O MANUFACTURER AND CATALOG NUMBERS. SEE ARCHITECTURAL DRAWINGS FOR INSTALLATION DETAILS. c 0 FOR THE FURNISHING AND INSTALLING OF ACCESS PANEL BY G.C. 41 0 : Q 25 CONTROL RELAY MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE CEILING FOR LIGHTING CONTROL O9 MOUNT RECEPTACLE HORIZONTAL AT 6" A.F.F. COORDINATE LOCATION IN BASE OF COLUMN 17 J—BOX MOUNTED ABOVE THE CEILING FOR POWER TO FUTURE SENSORMATIC EQUIPMENT. SYSTEM TIE—IN TO TEMP. CONTROL PANEL. REFER TO WIRING DIAGRAM ON DRAWING E4.1. d WITH MIRROR INSTALLATION. INSTALL ON NON—MIRRORED SURFACE, VERIFY LOCATION W COORDINATE CONNECTION WITH SENSORMATIC REPRESENTATIVE. WITH H&M PROJECT MANAGER. 26 FLUSH JUNCTION BOX FOR POWER TO TEMP. CONTROL PANEL. VERIFY EXACT LOCATION AND 18 COORDINATE REQUIREMENTS OF THE SECURITY CONTACT FOR THE ROLLING GRILLE WITH THE MOUNTING HEIGHT WITH M.C. 10 DATA OUTLET WITH (1) ONE CAT 5E CABLE 6" BELOW CEILING FOR WIRELESS NETWORK NODE. SECURITY SYSTEM CONTRACTOR. FURNISH AND INSTALL CONDUIT WITH PULLWIRE AND (NONE SHOWN) BACKBOX, AS REQUIRED. 27 ELECTRIC J -BOX ABOVE CEILING FOR FUTURE EMPLOYEE CARD SWIPE. PROVIDE CONDUIT, WIRE & LOOP.FOR FUTURE EMPLOYEE CARD SWIPE. 11 DOORBEL SYSTEM. REFER TO WIRING DIAGRAM ON DWG. E4.1. 19 DUPLEX OUTLET AND (2) DATA JACK FOR EMPLOYEE TIME CLOCK MOUNTED AT 48" A.F.F. 12 CONTRACTOR SHALL INSTAL IG RECEPTACLE AND TEL/DATA DEVICE CLOSEST TO REGISTER 20 SENSORMATIC FULLY CONCEALED DIGITAL FLOORMAX ANTENNAS. ROUTE (2) 3/4" RIGID CONDUIT 28 PROVIDE TELECOMMUNICATIONS CONDUIT WITHIN FLOOR OR WITHIN ACCESSIBLE CEILING OF FLOOR BELOW BETWEEN CASHWRAP AND NEAREST WALL METHOD OF PORTION OF THE CASH DESK (TYPICAL OF ALL CASH REGISTERS). COORDINATE FINAL WITH PULLSTRING IN THE FLOOR TO A FULL HEIGHT WALL AND STUB INTO AN ACCESSIBLE CORE DRILLING, TRENCHING, ETC. SHALL BE PER BUILDING REQUIREMENTS. LOCATION WITH ARCHITECT PRIOR TO COMMENCEMENT. CEILING SPACE FOR FUTURE SENSORMATIC CABLES (BY SENSORMATIC), TYPICAL. THE E.C. CONDUIT SIZE SHALL BE 1-1/4". O13 DEDICATED CIRCUITS FOR HOLIDAY ROLL -AWAY CASHWRAPS, () RAPS. E.C. SHALL INSTALL SHALL COORDINATE WITH H&M AND SENSORMATIC FOR EXACT LOCATIONS AND REQUIREMENTS FOR SENSORMATIC EQUIPMENT ROUGH—IN. 29 PROVIDE POWER CONDUIT WI 'HIN FLOOR OR WITHIN ACCESSIBLE CEILING OF FLOOR RECEPTACLES FOR ALL ROLL—AWAY CASHWRAPS. RECEPTACLES TO BE LOCATED AT BELOW BETWEEN CASHWRAP AND NEAREST WALL. METHOD OF CORE DRILLING, CONVENIENT LOCATION FOR ADDITIONAL CASHWRAPS. VERIFY LOCATION WITH H&M. 21 COORDINATE ELECTRICAL REQUIREMENTS OF THE ROLLING GRILLE IN THE FIELD. ROLLING TRENCHING, ETC. SHALL BE PER BUILDING REQUIREMENTS. CONTRACTOR SHALL 14 PROVIDE CONDUIT WITH PULL WIRE FROM CASHWRAP BASEMENT LEVEL LAN ROOM GRILLE BY OTHERS; CONTROLS INTERLOCK (KEY SWITCHES) SHALL BE MOUNTED AT 48" SIZE CONDUIT PER NEC SPECIFICATIONS. FOR DATA CABLE. REFER TO CONDUIT FILL REQUIREMENTS CHARTS FOR CONDUIT A.F.F. ON BOTH THE TENANT AND MALL SIDES OF ROLLING GRILLE BY E.C.. VERIFY FINAL SIZE ON DWG E5.3. COORDINATE EXACT REQUIREMENT WITH G.C. AND ARCHITECT. LOCATIONS WITH TENANT. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. (TYP. Al CASHWR HOLIDAY CASHWRAP 63 I ICA -7 a LIGA-12,14 IICA-16.18 L.P2-1,3 ALL WIRING SHALL DE IN CONDUIT OR FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. . i7i A, CLOSET 45 SM VT 7 - tet= 1/4" = 1'_0„ PLUMBING CODED NOTES 5 EWH-1; 20 208V-10 DOMESTIC ELECTRIC WATER HEATER— PROVIDE A2 A 2 2 8V NEMA 1 DISCONNECT SWITCH AT THE UN 3 1 1#12(G) -3/4"C. FROM A 20A/1P BREAKER AT THE PAN 2 TO THE SWITCH. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. HOLIDAY CASHWRAP THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: JEFFERY D. MITERKO PE: 0051703 ❑ programming E13:0007857 ® schematic des. Expires: 2/28/11 ❑ design dev. Consultants: ❑ bidding f'AIIE DESM CONSMANT N permits JOA w LU 29110 Inkster Road ® landlord prelim. Suite 200 ® landlord final Southfleld, MI 48034 USA REVISIONS: 248 355 0890 248 355 0895 Fax M PW%a p z= X& ka M r" n-ww wanr. j G.= JGA Pr j #: 1-209-057 DRAWINGS ISSUED 4 ❑ programming ® schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding N permits 03.12.09 LU U ® landlord prelim. 02.0q.0q ® landlord final 02.27.0q REVISIONS: � V w o � Q U m t— Q 1_ LU LQw U O < c 0 41 0 : Q Q 0 O tu Q t— d lY W DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding N permits 03.12.09 ❑ construction ® landlord prelim. 02.0q.0q ® landlord final 02.27.0q REVISIONS: 1Q ADDENDUM #1 03.12.09 Prj. no. 8-20q-012 Drawn T13A Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: POWER PIAN Sheet no. • 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: VVV��3c Q JEFFERY D. MITERKO PE: 0051703 4 ❑ design dev. EB:0007857 ❑ bidding Expires: 2/28/11 U - Lu Consultants: N landlord prelim. 2 WALDE8MCON&VANT 02.27.0q REVISIONS: JGA w L � 29110 Inkster Road Suite 200 o N Southfleld, MI 48034 USA 248 355 0890 248 355 0895 Fax c�yP+u,e 012 1 he � www. jga.com Qg JGA Pr j #: 1-209-057 DRAWINGS ISSUED Q ❑ programming M schematic des. 4 ❑ design dev. ❑ bidding ® permits U - Lu V N landlord prelim. 2 :z� 02.27.0q REVISIONS: L � � o N to w Qg U O LU c 0 v LU < J O:Z;� .9 Q �$.91 0 0 DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.0q.0q ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction N landlord prelim. 02.0q.0q 11landlord final 02.27.0q REVISIONS: Prj. no. 8-209-012 Drawn T13A Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: AUDIO PLAN Sheet no. E3*2 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: 1Q ADDENDUM #1 03.12.09 Prj. no. B-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: SECURITY PIAN Sheet no. 4 DRAWINGS ISSUED FOR: ❑ programming O M schematic des. 02.0q.0q ❑ design dev. ❑ bidding ® permits LLI ❑ construction IN landlord prelim. W ® landlord final co � U-1 O CY J � N 'Q LLA w O Lu < o J LL < ' a LU O (� Z V Q Cv W I -- 1Q ADDENDUM #1 03.12.09 Prj. no. B-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: SECURITY PIAN Sheet no. 4 DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.0q.0q ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction IN landlord prelim. 02.0q.0q ® landlord final OZ27.0q 1Q ADDENDUM #1 03.12.09 Prj. no. B-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: SECURITY PIAN Sheet no. 4 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: JEFFERY D. MITERK0 PE: 0051703 EB: 0007857 Expires: 2/28/11 Consultants: Q NQ FtETAL DESIGN CONSULTANT JGA i c 02.Oq.Oq 29110 Inkster Road Suite 200 111 Southfield, MI 48034 USA 03.12.0q 248 355 0890 � 248 355 0895 Fax .a W". jguxom JGA Prj #: 1-209-057 DRAWINGS ISSUED Q NQ ❑ programming 9 schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding til permits 03.12.0q LU � ® landlord prelim. cs 9 landlord final < REVISIONS: LU LU o m a� L Lu w o �� o < ® z p i— O< .21 tu q Q O ELtr— DRAWINGS ISSUED FOR: ❑ programming 9 schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding til permits 03.12.0q ❑ construction ® landlord prelim. 02.Oq.Oq 9 landlord final 02.27.09 REVISIONS: An ADDENDUM #1 03.12.09 E IL ro N N d E r- 0) 2 0 N M 0 0 0 _u 0 U N rn L, w 0 0 0 0 0 E 0 z 0 Prj. no. B-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: HVAC POWER PLAN Sheet no. &M= ASTAk • 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: V � V � JEFFERY D. WTERKO PE: 0051703 EB: 0007857 Expires: 2/28/11 Consultants: F tETAIL DESIGN CONSULTANT JOA m 29110 Inkster Road Suite 200 Southfield, MI 48034 USA i 248 355 0890 248 355 0895 Fax °op rdA , km www.jga.C= JGA Prj #: 1--209-057 A I DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.0q.0q ❑ design dev. ❑ bidding H permits 03.12.Oq Lim v 0landlord prelim. 02.0q.09 N landlord final 02.27.0q REVISIONS: co LU � `J � o LU U LU Q XLQv m o C� C� U -1 o LLI LL- < U J A ~ n, D LU O } DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.0q.0q ❑ design dev. ❑ bidding H permits 03.12.Oq ❑ construction 0landlord prelim. 02.0q.09 N landlord final 02.27.0q REVISIONS: 1Q ADDENDUM #1 03.12.Oq Prj. no. B-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: FIRE ALARM PLAN Sheet no. POWERLINK 3000 INPUT TERMINAL BOARD 3/C #16 SEE NOTE 1 POWERLINK INPUT TERMINAL WIRING DIAGRAM NO SCALE POWERLINK INPUT WIRING NOTES: 1. 2 -BUTTON LOW VOLTAGE MOMENTARY SWITCH WITH PILOT LIGHT WITH NORMALLY CLOSED CONTACT SERVING AS AN OVERRIDE OF THE TIMED SCHEDULE. THE FIRST BUTTON SHAL ENABLE CLEANING AND SALES LIGHTING ZONES, SERVE AS A 2 -HOUR TIMED OVERRIDE OF THE LIGHTING CONTROL SYSTEM (Z1 AND Z2), AND SHALL BE WIRED TO INPUT 1 ON THE CONTROLLER. THE SECOND BUTTON SHALL ENABLE CLEANING AND SALES LIGHTING ZONES, SERVE AS A 4 -HOUR TIMED OVERRIDE OF THE U"AffHNG CONTROL SYSTEM (Z1 AND Z2), AND SHALL BE WIRED TO INPUT 2 ON THE CONTROLLER. THIS SWITCH SHALL BE MOUNTED IN THE CASH OFFICE/ADMINISTRATIVE OFFICE. SWITCH SHALL BE XXXXXXX WITH A LOW VOLTAGE NEON LIGHT. PROVIDE A PHENOLIC LABEL WITH BLACK BACKGROUND AND WHITE LETTERING INDICATING FUNCTION FOR SWITCH. SWITCH TO BE PROVIDED AS PART OF THE SQUARE D POWER DISTRIBUTION PACKAGE (1) QUAD CONVENIENCE RECEPTACLE, 1 QUAD I.G. RECEPTACLE, AND DATA JACKS MOUNTED TO BACK SIDE OF MILLWORK, LOCATED UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/SELVES FOR BAGS (TYPICAL). HAND HOLE FOR ROLL -UP HOLIDAY CASHWRAPS. 16 ELEVATION 99A„ ADMIN ROOD WALL ELEVATIONS NO SCALE GENERAL NOTES 1. VERIFY LOCATION OF H&M FURNISHED SERVER/CABINET BELOW COUNTER WITH H&M REP. ON SITE PRIOR TO ROUGH -IN OF DEVICES BELOW COUNTER. THESE DEVICES SHALL BE INSTALLED ADJACENT TO CABINET. 2. ALL JACKS ARE ARBITRARILY LABELED AS DATA, AS DATA AND TELEPHONE USE THE SAME JACKS. THE H&M I.T. REPRESENTATIVE SHALL DETERMINE WHICH JACKS ARE FOR DATA AND WHICH ARE FOR PHONE. SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 POWERLINKPOWERLINK POWER SUPPLYj I 3000 SERIES CONTROLLER POWERLINK MASTER PANEL (HP1) 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SOL03 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSEL G3 SUBNET CABLE (CLASS 1), 4-WIRE,18AWG, BELDEN #27326 TYPICAL BETWEEN PANELS) INPUT TERMINAL WIRING TO BURGLAR ALARM AND KEY SWITCH.. REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM. 21 SPACE CONTROL BUS, SQUARE D CAT No. NF2ISBLG3 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 — - E.C. SHALL PROVIDE CONDUIT AND T.C. SHALL PROVIDE (1) CAT. 5 SHIELDED CABLE TO DATA RACK WITH STANDARD CAT. 5 CONNECTOR TERMINATION. PUNCHDOWN AT DATA RACK B, PORT NUMBER 24 IN LAN ROOM. LABEL PORT "LIGHTING SYSTEM". - 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21 SBRG3 WIRING TO OVERRIDE SWITCHES REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM. WIRING TO OCCUPANCY SENSOR POWER PACKS. EXACT QUANTITY TO BE DETERMINED. SUBNET CABLE (CLASS 1), 4 -WIRE, 118AWG, BELDEN #27326 TYPICAL BETWEEN PANELS) SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBRG3 POWERLINK SLAVE PANEL (LP1 - SECTION 1) SECTION VIEW F—A 21 SPACE CONTROL BUS, SQUARE D CAT No. NF2ISBLG3 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 — L IG I I UGA-10 NO SCALE ALSO SEE ADMIN ROOM WALL ELEVATION(S), THIS SHEET. CODED NOTES �1 QUAD I.G. MOUNTED ABOVE CEILING AT DOOR FOR POWER TO DOOR LOCK. SUBNET CABLE (CLASS 1), 4 -WIRE, 18AWG, BELDEN #27326 TYPICAL BETWEEN PANELS) SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 18,SPACE CONTROL BUS, SQUARE D CAT No. NFI8SBLG3 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 -- 21 SPACE CONTROL BUS, --� SQUARE D CAT No. NF2ISBRG3 POWERLINK SLAVE PANEL (LP1 SECTION 2) I.G. DATA u " DATA JACKS MOUNTED VERTICALLY IN SURFACE BOX TO BACK SIDE OF MILLWORK. PROVIDE (4) DATA JACKS FOR EACH jig OF REGISTERS AT EACH CASHWRAP LOCATION. LOCATE DIRECTLY UNDER ACCESS COVER PLATE BELOW FOLDING AREA/SELVES FOR BAGS, SEE POWER PLANS FOR EXACT QUANTITY OF DATA JACKS REQUIRED. SYMBOL ON DWG. - ® UD) (1) DUPLEX ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS FOR HOLIDAY C GSHWRAP. (TYPICAL). SYMBOL ON DWG. - I.G. CASH WRAP, REFER TO POWER PLAN(S) FOR IN FLOOR ROUTING. PROVIDE END BUSHING ON CONDUIT. JUNCTION BOX FOR CASH WRAP BRANCH CIRCUIT NORMAL POWER WIRING, REFER TO POWER PLAN(S) FOR IN FLOOR CONDUIT ROUTING. (1 1/2" C) (ONLY USED IF TRENCHING IS PERMITTED) JUNCTION BOX FOR CASH WRAP BRANCH CIRCUIT ISO. GROUND POWER WIRING, REFER TO POWER PLAN(S) FOR IN FLOOR CONDUIT ROUTING. (1 1/2" C) (ONLY USED IF TRENCHING IS PERMITTED) ACK VIEW (4 REGISTER% NO SCALE DATA I.G. (1) QUAD ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. - (1) QUAD CONVENIENCE RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. - FINISHED FLOOR I.G. CIRCUIT ISOLATED GROUND POWER WIRING. PROVIDE (1) HUBBELL PT7XC WITH 2 -GANG PEDESTAL SERVICE FITTING FR80AL AND FURNITURE FEED OPENING SS309SF. USE 1-1/4" STEM FOR POWER WIRING. BRANCH TO DEVICES VIA LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. - 6) ROUTE NORMAL POWER WIRING VIA THE 1/2"C. STEM IN THE HUBBELL FIRE RATED POKE -THROUGH, PROVIDE AN SS309SF FACE PLATE FOR NORMAL POWER. BRANCH TO DEVICES VLA LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. FIRE RATED POKE -THROUGH FOR DATA WIRING FOR CASH WRAP. PROVIDE (1) HUBBELL P17XC WITH 2 -GANG PEDESTAL SERVICE FITTING FR80AL AND BUSHED DATA OPENING FACE PLATE SS309T. USE 1-1/4" STEM FOR DA WIRING. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. - H LP2-14 N 120VAC-10 TRANSFORMER - EDWARDS IOVAC #590 MOUNTED TO 4" SQ. BOX ON WALL IN STOCK ROOM. Z PUSHBUTTON - EDWARDS BUZZER(S) - EDWARDS #661 #600 QUANTITY AS FLUSH MOUNTED 0 8'-0" INDICATED ON PLANS. A.F.F. AT BACK OF HOUSE WIRE PUSHBUTTONS IN OR ON CEILING IN SALES PARALLEL AREA. QUANTITY AS INDICATED ON PLANS. DOORBELL WIRING DIAGRAM NO SCALE IE: ALL LOW VOLTAGE WIRING TO BE #14AWG. SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 18 SPACE CONTROL BUS,- SQUARE D CAT No. NFI8SBRG3 POWERLINK SLAVE PANEL (LP3) NOTES: 1. THE COMPLETE POWERLINK LIGHTING CONTROL SYSTEM -PANELS, POWER SUPPLY, CONTROLLER, CONTROL BUSES, SLAVE BUS HARNESS AND CONTROLLABLE CIRCUIT BREAKERS SHALL BE FURNISHED, INSTALLED AND WIRED BY THE E.C. 2. THE TOTAL NUMBER OF CONTROLLABLE BREAKERS SHALL BE EQUAL TO THE TOTAL NUMBER OF CONTROL BUS POSITIONS IN EACH POWERLINK PANEL 3. SUBNET CABLE SHALL BE FURNISHED AND INSTALLED BY THE E.C. 4. REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM FOR MORE INFORMATION. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE AL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. L1GA-3 IG PAR LIGA-1 r _ O I�GA�+211 IG 4 00 . FT. +60 4 Lc i LGA -13 LIGA-5 H 120VAC, LP3-31 N RCONTROL RELAY: CUTLER -HAMMER JD15CR22AB WITH (2) N.O. CONTACTS AND (2) N.C. CONTACTS, MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE MANAGER'S OFFICE LAY -IN CEILING. PROVIDE A CUTLER -HAMMER #C321MP1 MOUNTING PLATE. ENCLOSURE SHALL BE HOFFMAN #A8N86 WITH HOFFMAN JMN8P BACK PANEL R1 TO HVAC CONTROL PANEL WIRING BY E.C. COORDINATE WITH T.C. CONTRACTOR WIRING DIAGRAM LIGHTING CONTROL TIE—IN TO HVAC CONTROLS NO SCALE -T-ISO HUNG FROM STRUCTURE ABOVE PNLS Ol-0� LGA i Off. F i(n) -�/ MDP �1 LIGA-22,24 SOUND SYSTEM RACK i O a T-2 STACKED ABOVE T-1. UNI -STRUT iTWO STACKED STRUCTURE BY E.C. ------ TRAK PAK PANELS ami— LP1 (SEC 1) LP3 LP1 (SEC 2) ENLARGED ELECTRIC LAN ROOM PLAN NO SCALE E.C. SHALL COORDINATE ALL ELECTRICAL EQUIPMENT LOCATIONS WITH THE MECHANICAL AND PLUMBING TRADES. CODED NOTES Oj (2) QUAD I.G. RECEPTACLES CENETERED AND EQUALLY SPACED BEHIND RACK FOR SOUND SYSTEM POWER. ® JUNCTION BOX AND QUAD I.G. RECEPTACLE FOR SECURITY PANEL �3 JUNCTION BOX FOR SPEAKER WIRING. �4 8'H.x8'W.x3/4"D. FIRE TREATED PLYWOOD BOARD. MOUNT AT 24" A.F.F. TO BOTTOM. (TYP OF 2) ® TWO POST NETWORK LADDER DATA RACK WITH 3" UPRIGHTS. REFER TO SPECIFICATION SECTION 16740.H FOR MORE DETAIL/INFORMATION. RACK BASE SHALL BE LOCATED 6" FROM WALL WITH PLYWOOD BOARD AND 22" FROM ADJACENT WALL QUAD OUTLET SHALL BE INSTALLED BY E.C. IN LINE WITH RACK BASE 1-1/2"C. W/PULLSTRING BY H&M'S E.C. FOR TELEPHONE SERVICE FROM LL TELEPHONE CLOSET TO POINT IN H&M SPACE. VERIFY IN FIELD EXACT LOCATION OF MAIN TELEPHONE BOARD AS WELL AS ANY INTERMEDIATE BOARD LOCATIONS. TECHNOLOGY CONTRACTOR TO PROVIDE CAI RATED 25 -PAIR CABLE FROM LL TELEPHONE CLOSET (APPROX 300'-0" +/-). REFER TO SPECIFICATION SECTION 16740.M.12 FOR MORE INFORMATION. COORDINATE REQUIRED DISTANCE WITH LL PRIOR TO SUBMITTING BID. E.C. SHALL COORDINATE LOCATION OF SMART JACK, FOR H&M WITH TELEPHONE COMPANY, TO BE LOCATED WITHIN 300 FEET OF THE H&M SPACE. LIGHTING CONTROL SCHEDULE CASH REGISTER I L ----L CASH REGISTER I L ----L FUNCTION I CASH REGISTER I L ----J I CASH REGISTER L----� ZONE FOR USE BY TEMPERATURE CONTROL SYSTEM TO DETERMINE THE PROGRAMMED HOURS SUCH THAT DURING THE HOURS OF STATUS OF THE STORE AS "OCCUPIED" (RELAY CONTACT CLOSED) 5:30 A.M. AND 12:00A.M. (MIDNIGHT) ZONE 1 AND THE LIGHTING Z1 HP1-3,7,11,15,1721,25 CLEANING LTG. (50%), QL ON - 5:30 A.M. (OR AS DIRECTED BY H&M ON SITE) 1 REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE 02.27.Oq LTG AND B -O -H LTG OFF - 12:30 A.M. - MIDNIGHT (OR AS DIRECTED BY H&M ON SITE) 29110 Inkster Road - f HP1-2,6,10,14,18,20,22 GEN. SALES LTG. (50%) ON - TIMED, ONE HOUR PRIOR TO NORMAL. STORE HOURS 2 CONTROLLER. THE LIGHTING SHALL BE ENABLED ONE HOUR PRIOR LP3-1,3 AND COVE LTG. OFF - TIMED, ONE HOUR PAST NORMAL STORE HOURS THAT DURING THESE HOURS ZONE 2 AND THE LIGHTING Z2 LP1-1,3,5,7,9,11,13,15,17, TRACK LTG ON - TIMED, ONE HOUR PRIOR TO NORMAL STORE HOURS 2 ACCESS COVER PLATE TYPICAL D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START-UP. OFF - TIMED, ONE HOUR PAST NORMAL STORE HOURS 31,33,35,37,39,41, U 43,45,47,49,51,53, LLA of [,_ 55,57,59,61,63,65, i LZ o 0 67,69,71,73,75,77 C3 Q LP1-2,4,6,8,10,12,14;16,18, ��O O 00 C3 C3 O(= 00 00 JB JB O= DO OD 00 o N DD C30 0= C30 32,34,36,38,40,42, ' PT PT. I oo DO 00 I.G. DATA u " DATA JACKS MOUNTED VERTICALLY IN SURFACE BOX TO BACK SIDE OF MILLWORK. PROVIDE (4) DATA JACKS FOR EACH jig OF REGISTERS AT EACH CASHWRAP LOCATION. LOCATE DIRECTLY UNDER ACCESS COVER PLATE BELOW FOLDING AREA/SELVES FOR BAGS, SEE POWER PLANS FOR EXACT QUANTITY OF DATA JACKS REQUIRED. SYMBOL ON DWG. - ® UD) (1) DUPLEX ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS FOR HOLIDAY C GSHWRAP. (TYPICAL). SYMBOL ON DWG. - I.G. CASH WRAP, REFER TO POWER PLAN(S) FOR IN FLOOR ROUTING. PROVIDE END BUSHING ON CONDUIT. JUNCTION BOX FOR CASH WRAP BRANCH CIRCUIT NORMAL POWER WIRING, REFER TO POWER PLAN(S) FOR IN FLOOR CONDUIT ROUTING. (1 1/2" C) (ONLY USED IF TRENCHING IS PERMITTED) JUNCTION BOX FOR CASH WRAP BRANCH CIRCUIT ISO. GROUND POWER WIRING, REFER TO POWER PLAN(S) FOR IN FLOOR CONDUIT ROUTING. (1 1/2" C) (ONLY USED IF TRENCHING IS PERMITTED) ACK VIEW (4 REGISTER% NO SCALE DATA I.G. (1) QUAD ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. - (1) QUAD CONVENIENCE RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. - FINISHED FLOOR I.G. CIRCUIT ISOLATED GROUND POWER WIRING. PROVIDE (1) HUBBELL PT7XC WITH 2 -GANG PEDESTAL SERVICE FITTING FR80AL AND FURNITURE FEED OPENING SS309SF. USE 1-1/4" STEM FOR POWER WIRING. BRANCH TO DEVICES VIA LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. - 6) ROUTE NORMAL POWER WIRING VIA THE 1/2"C. STEM IN THE HUBBELL FIRE RATED POKE -THROUGH, PROVIDE AN SS309SF FACE PLATE FOR NORMAL POWER. BRANCH TO DEVICES VLA LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. FIRE RATED POKE -THROUGH FOR DATA WIRING FOR CASH WRAP. PROVIDE (1) HUBBELL P17XC WITH 2 -GANG PEDESTAL SERVICE FITTING FR80AL AND BUSHED DATA OPENING FACE PLATE SS309T. USE 1-1/4" STEM FOR DA WIRING. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. - H LP2-14 N 120VAC-10 TRANSFORMER - EDWARDS IOVAC #590 MOUNTED TO 4" SQ. BOX ON WALL IN STOCK ROOM. Z PUSHBUTTON - EDWARDS BUZZER(S) - EDWARDS #661 #600 QUANTITY AS FLUSH MOUNTED 0 8'-0" INDICATED ON PLANS. A.F.F. AT BACK OF HOUSE WIRE PUSHBUTTONS IN OR ON CEILING IN SALES PARALLEL AREA. QUANTITY AS INDICATED ON PLANS. DOORBELL WIRING DIAGRAM NO SCALE IE: ALL LOW VOLTAGE WIRING TO BE #14AWG. SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 18 SPACE CONTROL BUS,- SQUARE D CAT No. NFI8SBRG3 POWERLINK SLAVE PANEL (LP3) NOTES: 1. THE COMPLETE POWERLINK LIGHTING CONTROL SYSTEM -PANELS, POWER SUPPLY, CONTROLLER, CONTROL BUSES, SLAVE BUS HARNESS AND CONTROLLABLE CIRCUIT BREAKERS SHALL BE FURNISHED, INSTALLED AND WIRED BY THE E.C. 2. THE TOTAL NUMBER OF CONTROLLABLE BREAKERS SHALL BE EQUAL TO THE TOTAL NUMBER OF CONTROL BUS POSITIONS IN EACH POWERLINK PANEL 3. SUBNET CABLE SHALL BE FURNISHED AND INSTALLED BY THE E.C. 4. REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM FOR MORE INFORMATION. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE AL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. L1GA-3 IG PAR LIGA-1 r _ O I�GA�+211 IG 4 00 . FT. +60 4 Lc i LGA -13 LIGA-5 H 120VAC, LP3-31 N RCONTROL RELAY: CUTLER -HAMMER JD15CR22AB WITH (2) N.O. CONTACTS AND (2) N.C. CONTACTS, MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE MANAGER'S OFFICE LAY -IN CEILING. PROVIDE A CUTLER -HAMMER #C321MP1 MOUNTING PLATE. ENCLOSURE SHALL BE HOFFMAN #A8N86 WITH HOFFMAN JMN8P BACK PANEL R1 TO HVAC CONTROL PANEL WIRING BY E.C. COORDINATE WITH T.C. CONTRACTOR WIRING DIAGRAM LIGHTING CONTROL TIE—IN TO HVAC CONTROLS NO SCALE -T-ISO HUNG FROM STRUCTURE ABOVE PNLS Ol-0� LGA i Off. F i(n) -�/ MDP �1 LIGA-22,24 SOUND SYSTEM RACK i O a T-2 STACKED ABOVE T-1. UNI -STRUT iTWO STACKED STRUCTURE BY E.C. ------ TRAK PAK PANELS ami— LP1 (SEC 1) LP3 LP1 (SEC 2) ENLARGED ELECTRIC LAN ROOM PLAN NO SCALE E.C. SHALL COORDINATE ALL ELECTRICAL EQUIPMENT LOCATIONS WITH THE MECHANICAL AND PLUMBING TRADES. CODED NOTES Oj (2) QUAD I.G. RECEPTACLES CENETERED AND EQUALLY SPACED BEHIND RACK FOR SOUND SYSTEM POWER. ® JUNCTION BOX AND QUAD I.G. RECEPTACLE FOR SECURITY PANEL �3 JUNCTION BOX FOR SPEAKER WIRING. �4 8'H.x8'W.x3/4"D. FIRE TREATED PLYWOOD BOARD. MOUNT AT 24" A.F.F. TO BOTTOM. (TYP OF 2) ® TWO POST NETWORK LADDER DATA RACK WITH 3" UPRIGHTS. REFER TO SPECIFICATION SECTION 16740.H FOR MORE DETAIL/INFORMATION. RACK BASE SHALL BE LOCATED 6" FROM WALL WITH PLYWOOD BOARD AND 22" FROM ADJACENT WALL QUAD OUTLET SHALL BE INSTALLED BY E.C. IN LINE WITH RACK BASE 1-1/2"C. W/PULLSTRING BY H&M'S E.C. FOR TELEPHONE SERVICE FROM LL TELEPHONE CLOSET TO POINT IN H&M SPACE. VERIFY IN FIELD EXACT LOCATION OF MAIN TELEPHONE BOARD AS WELL AS ANY INTERMEDIATE BOARD LOCATIONS. TECHNOLOGY CONTRACTOR TO PROVIDE CAI RATED 25 -PAIR CABLE FROM LL TELEPHONE CLOSET (APPROX 300'-0" +/-). REFER TO SPECIFICATION SECTION 16740.M.12 FOR MORE INFORMATION. COORDINATE REQUIRED DISTANCE WITH LL PRIOR TO SUBMITTING BID. E.C. SHALL COORDINATE LOCATION OF SMART JACK, FOR H&M WITH TELEPHONE COMPANY, TO BE LOCATED WITHIN 300 FEET OF THE H&M SPACE. LIGHTING CONTROL SCHEDULE LIGHTING CIRCUIT(S) FUNCTION CONTROL SEQUENCE NOTES ZONE FOR USE BY TEMPERATURE CONTROL SYSTEM TO DETERMINE THE PROGRAMMED HOURS SUCH THAT DURING THE HOURS OF STATUS OF THE STORE AS "OCCUPIED" (RELAY CONTACT CLOSED) 5:30 A.M. AND 12:00A.M. (MIDNIGHT) ZONE 1 AND THE LIGHTING Z1 HP1-3,7,11,15,1721,25 CLEANING LTG. (50%), QL ON - 5:30 A.M. (OR AS DIRECTED BY H&M ON SITE) 1 REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE 02.27.Oq LTG AND B -O -H LTG OFF - 12:30 A.M. - MIDNIGHT (OR AS DIRECTED BY H&M ON SITE) 29110 Inkster Road Z2 HP1-2,6,10,14,18,20,22 GEN. SALES LTG. (50%) ON - TIMED, ONE HOUR PRIOR TO NORMAL. STORE HOURS 2 CONTROLLER. THE LIGHTING SHALL BE ENABLED ONE HOUR PRIOR LP3-1,3 AND COVE LTG. OFF - TIMED, ONE HOUR PAST NORMAL STORE HOURS THAT DURING THESE HOURS ZONE 2 AND THE LIGHTING Z2 LP1-1,3,5,7,9,11,13,15,17, TRACK LTG ON - TIMED, ONE HOUR PRIOR TO NORMAL STORE HOURS 2 REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE 19,21,23,25,27,29, D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START-UP. OFF - TIMED, ONE HOUR PAST NORMAL STORE HOURS 31,33,35,37,39,41, U 43,45,47,49,51,53, LLA of [,_ 55,57,59,61,63,65, LZ o 0 67,69,71,73,75,77 C3 Q LP1-2,4,6,8,10,12,14;16,18, a Ltj~ �o z 20,22,24,26,28,30, o N U) iQ-- 32,34,36,38,40,42, 44,46,48,50,52,54, 56,58,60,62,64,66, 68,70,72 LP3-2,4,6 Z2 LP3-5,7,9,11,13,15,17,21,2 POP -OUT WALL LTG, ON - TIMED, ONE HOUR PRIOR TO NORMAL STORE HOURS 2 LP3-20 MIRROR LTG, FEATURE OFF - TIMED, ONE HOUR PAST NORMAL STORE HOURS WALL LTG, EWC, WATER COOLER Z3 LP3-8,10,12,14,16,18 SHOW WINDOW TRACK ON - TIMED 4 LP3-25,27,29 AND SIGNAGE OFF - TIMED Z1 LP3-19,31 TEMP. CTL RELAY, EF -1 ON - 5:30 A.M. (OR AS DIRECTED BY H&M ON SITE) 1,3 OFF - 12:30 A.M. - MIDNIGHT (OR AS DIRECTED BY H&M ON SITE) NOTES: Q 1. REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM ON THIS 3. CONTROLLED CIRCU(LP3-31 SHALL BE USED TO CONTROL A DRAWING FOR A 2HR AND 4HR OVERRIDE OF THE LIGHTING RELAY COIL THE RE PROVIDE A NORMALLY OPEN CONTACT CONTROLLER. THE LIGHTING SHALL BE ENABLED VIA THE NORMAL FOR USE BY TEMPERATURE CONTROL SYSTEM TO DETERMINE THE PROGRAMMED HOURS SUCH THAT DURING THE HOURS OF STATUS OF THE STORE AS "OCCUPIED" (RELAY CONTACT CLOSED) 5:30 A.M. AND 12:00A.M. (MIDNIGHT) ZONE 1 AND THE LIGHTING OR "UNOCCUPIED" (RELAY CONTACT OPEN). REFER TO "LIGHTING CONTROLLER TIMER SHALL ENABLE. THE E.C. SHALL VERIFY "WIRING DIAGRAM - LIGHTING CONTROL TIE-IN TO HVAC CONTROLS" ON/OFF PROGRAM TIMES FROM THE ON-SITE H&M DETAIL ON DRAWING E4.1. REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE 02.27.Oq D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START-UP. 4. THE E.C. SHALL VERIFY ON/OFF PROGRAM TIMES FROM THE ON-SITE H&M 29110 Inkster Road REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE 2. REFER TO POWERLINK INPUT TERMINAL WIRING DIAGRAM ON THIS D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START-UP. DRAWING FOR A 2HR AND 4HR OVERRIDE OF THE LIGHTING it CONTROLLER. THE LIGHTING SHALL BE ENABLED ONE HOUR PRIOR • �' TO ONE HOUR PAST NORMAL PROGRAMMED STORE HOURS SUCH 0,P10 2" TrVII =I- THAT DURING THESE HOURS ZONE 2 AND THE LIGHTING JGA Pr j #: CONTROLLER TIMER SHALL ENABLE. THE E.C. SHALL VERIFY ON/OFF PROGRAM TIMES FROM THE ON-SITE H&M REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START-UP. lo__ ALL WIRING 21ALL BE IN C4mum LIMIJ OR FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. ®'-�_ THORSON BAKER 8c Associates, Inc. Consulting Engineers 3030 West Streetsboro Rood 330 659-6688 Ph. Richfield, Ohio 44286 �330� 659-6675 FaX 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved Certification: FOR: 0 programming YV 11 schematic des. 8 JEFFERY D.,MITERKb , PE:0051703 EB: 0007857 03.12.Oq Expires: 2/28/11 Consultants: 02.Oq.0q LLI 02.27.Oq XA LNC C�3 29110 Inkster Road � Suite 200 2 Southfield, Ail 48034 USA it 248 355 0890 • �' 248 355 0895 Fax 0,P10 2" TrVII =I- www.jga.com JGA Pr j #: 1--209-057 DRAWINGS ISSUED FOR: 0 programming 11 schematic des. 8 0 design dev. 0 bidding ® permits 03.12.Oq 0 construction A landlord prelim. 02.Oq.0q LLI 02.27.Oq REVISIONS: C�3 � 2 LLI � • �' LU a M lo__ 4 U LLA of [,_ LZ o 0 C3 Q a Ltj~ �o z {- o N U) iQ-- DRAWINGS ISSUED FOR: 0 programming 11 schematic des. 02.0q,0q 0 design dev. 0 bidding ® permits 03.12.Oq 0 construction A landlord prelim. 02.Oq.0q M landlord final 02.27.Oq REVISIONS: 0 ADDENDUM #1 03,12.09 Prj. no. 8-209-012 Drawn TBA Checked JDM Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: ELECTRICAL DETAILS E CL N E P 0 N 0 a 0 I n 0 LYN 2 I Ui W 0 0 0 01 0 0 N E Z 0, 0 ELECTRICAL SPECIFICATIONS Se cation 1.6010 - General Provisions A. General 1. Requirements specified in Division 1, instructions to bidders, supplemental general conditions, special conditions, addenda, alternates, contract and proposal, along with Division 16 and all its sections, comprise the contract documents for the electrical contract, along with these specifications as though they were one, and anything implied by the specifications shall be interpreted as also implied by the drawings and vice versa. Provide necessary items for a complete installation of all electrically operated equipment listed in the specifications or shown on the contract drawings. 2. The architectural, structural, mechanical, plumbing and equipment drawings and specifications are incorporated into, and become a part of this division. This contractor shall examine all such drawings and specifications and become thoroughly familiar with the provisions contained therein. The submission of his bid shall indicate such knowledge. 3. Electrical drawings are diagrammatic. They are intended to show the approximate locations of equipment and conduit. Dimensions given on the plans, in figures, shall take precedence over scaled dimensions and shall be verified in the field. The electrical contractor shall layout all equipment rooms to make sure the equipment, as purchased, fits in the room or space shown. Exact location of all equipment shall be verified in the field and routing of conduits shall suit field conditions. 4. Until the time of installation, the architect reserves the right to make minor changes in the location of conduit and equipment without additional cost to the contract. 5. The electrical drawings and specifications are intended to supplement each other. Material and labor necessary to the project shall be furnished and installed even though not specifically mentioned in both. Labor and/or materials neither shown nor specified, but obviously necessary for the completion and proper functioning of the system, shall be furnished and installed by the electrical contractor. 6. Arrange all equipment substantially as shown on the drawings. Make deviations only where necessary to avoid interference. Check all equipment sizes against available space prior to shipment to avoid interference. 7. Examine the work of other trades insofar as their work comes in contact with or is covered by this work in no case attach to, or finish against any defective work or install work in a manner which will prevent proper installation of the work of other trades. 8. Electrical contractor shall verify with other trades all electrical characteristics of equipment requiring electrical connections, contractor shall verify voltage, phase and horsepower and shall notify engineer of any discrepancies prior to start of work. Electrical contractor shall provide disconnecting means and overload protection for all equipment, unless furnished integral with equipment package. 9. It is the intent of these drawings that this be a complete electrical job, any errors or omissions shall be brought to the attention of the engineer prior to bidding the job. B. Visit to the Site 1. This contractor shall visit the site of the work and familiarize himself with all conditions affecting his work. The submission of his proposal shall indicate such knowledge. No additional payment shall be made on claims that arise from a lack of knowledge of the existing conditions C. Code and Permits 1. Installation shall be in full accordance with all codes, rules and regulations of municipal, city, county, state and public utilities and all other authorities having jurisdiction over the premises. 2. Comply with any specification requirements that are in excess but not in conflict with code requirements. 3. The contractor shall secure and pay for all permits, plan reviews and certificates of inspection in connection with his work, required by the foregoing authorities. Before final payment of the contract is allowed, all certificates shall be delivered to the architect in duplicate. 4. Electrical material and equipment shall bear the UL label except where UL does not label such types of material and equipment. D. Shop Drawings Submittals 1. The electrical contractor shall submit five (5) sets of shop drawings, the shop drawings of the following equipment using the indicated numbering system and titles, shall be submitted through the architect to the engineer and then resubmitted for final approval if necessary. Shop drawings shall be submitted for the following items: . D.a. Wiring devices D. b. Panelboards, transformers and safety switches including fault . current study based on equipment being supplied. D.c. Lighting control sytem, contactors, time switches and photocell D.d. Lighting fixtures D.e. Communications cabling and equipment D.f. Fire alarm system 2. All submitted shop drawings (manufacturers' equipment descriptive sheets or vendors' prepared drawings) shall have the general contractor's or subcontractor's "stamp of approval" indicating that the item submitted is as called for on the plans and specifications, is approved by the general contractor or subcontractor, the date of approval and initialed by the person approving the submittal and the name of the company submitting said equipment for approval. 3. Submit bound brochures complete with a table of contents. Loose or stapled together sheets are not acceptable. Any submittals not in brochure form or not as specified shall be returned at the contractor's expense for resubmittal. 4. All descriptive literature shall be submitted in a three (3) hole brochure with a cover identifying the following: D.a. Name of the job D.b. Location of the job, address, city and state. D.c. Name and address of the company submitting the brochures. D.d. Date of the submittal. 5. Every effort shall be made, in checking the shop drawings, to detect and correct all errors, omissions and inaccuracies. Failure to do this will not relieve the electrical contractor of the responsibility for the proper and complete installation in accordance with the contract documents. E. As -built Drawings 1. Submit to the architect one set of reproducible (mylars) electrical drawings showing the as -built conditions. F. Standards and Substitutions 1. Wherever the words "approved by", "approved equal", "as directed" or similar phrases p are used in the following specifications, they shall be understood to refer to the owner as the approving agency. The name or make of any equipment or materials named in this specifications (whether or not the words "or approved equal" are used) shall be known as the "standard". 2. These specifications establish quality standard of materials and equipment to be provided. Specific items are identified by manufacturer, trade name or catalog designation. This contractor shall submit his base bid price based upon standard specified equipment described herein and as detailed on drawings and associated contract documents. These specifications are not to be considered proprietary the contractor may submit information on materials and manufacturers (other than those listed) for review by the architect and engineer no later than ten (10) days before bids are submitted. Manufacturers of products accepted by the architect and engineer will be listed in an addendum to the specifications as an acceptable substitution equipment accepted as detailed below and shall be shown as a separate add or deduct price to be factored into the base bid price by the architect and owner if accepted. 3. 5hQuld the contractor propose to furnish materials and equipment other than these specified or approved by addendum submit a written request for substitutions to the architect at the bid opening_ The request shall be an alternate to the original bid; be accompanied with complete descriptive (manufacturer, brand name, catalog number, etc.) and technical data for all items. Failure by this contractor to submit the requisite documentation detailed above shall be understood by the architect and engineer to indicate that substitute equipment will not be presented by the contractor for consideration. Such substitutions will not be considered after the bid opening date and delay of project will not be permitted for further inspection and evaluation after this date. 4. Where such substitutions alter the design or space requirements indicated on the drawings, include all items of cost for the revised design and construction including cost of all allied trades involved. 5. Acceptance or rejection of the proposed substitutions shall be subject to approval of the architect and engineer. If requested, the contractor shall submit (at his cost) inspection samples of both the specified and proposed substitute items. 6. In all cases where substitutions are permitted, the contractor shall bear any extra cost of evaluating the quality of the material and equipment to be provided. G. Testing and Placing in Service 1. Any material or equipment failing a test shall be repaired or replace at the contractors expense. 2. Tests shall include the following: G.a. Measure the load on each phase of the main service and each phase of every feeder under full load conditions. G.b. Measure the no-load and full -load voltages (phase to phase, phase to neutral and phase to ground for each phase of each service, of each separately derived system, and at each panelboard or transformer). G.c. Measure the ground resistance of the main service grounding electrode and the ground resistance of each separately derived system's grounding electrode. G.d. Make insulation resistance tests on all dry type transformers and motors. H. Interferences 1. Before the installation of any item begins, the electrical contractor shall carefully ascertain that it does not interfere with clearances for the erection of finish beams, columns, pilasters, walls or other structural or architectural members as shown on the architectural drawings. If any work is installed and the architectural design cannot be followed, this contractor shall, at his own expense, make changes in his work as directed by the architect to permit the completion of the architectural work in accordance with drawings and specifications. 2. It shall be the duty of this contractor to report any interferences between his work and that of any of the other contractors as soon as they are discovered. The architect shall determine which equipment will be relocated, regardless of which was installed first. His decision will be final. Section 1 601 0 (cont.) I. Quality Assurance 1. All products shall be new and of the type and quality specified. Where materials, equipment, apparatus or other products are specified by manufacturer, brand name, type of catalog number, such designation shall establish the standards of the desired quality and style. It is the intent of these specifications to establish a standard of quality of materials and equipment installed. lection 16050 - Basic Electrical Materials and Methods A. Nameplates 1. General: furnish and mount on each panelboard, switchboard (including branch switches), large junction box, safety switch, starter, remote control, push button station, and all similar controls, a nameplate descriptive of the equipment or equipment controlled 2. Provide black and white nameplates constructed from laminated phenolic with a white center core. Letters shall be engraved in the phenolic to form white letters 3/8" high. Fasten the nameplates with an adhesive type fastener. B. Mounting Accessories 1. This contractor shall furnish and install all angle iron, channel iron, rods, supports, hangers, concrete or plywood required to install, mount and support any electrical equipment or device called for on the plans. 2. Supporting material shall be complete with hangers, connectors, bolts, clamps and necessary accessories to make a complete installation. Supporting material shall be galvanized, painted or otherwise suitably finished. Products by Binkley, Steel City, or Raco will be acceptable. 3. All surface -mounted equipment on block walls shall be mounted on 3/4" plywood backboard. All floor -mounted equipment shall be installed on a 4" high concrete housekeeping pad. C. Execution 1. The electrical work for construction proposed shall conform to all federal (OSHA), state, all specific safety requirements and the requirements of the current edition of the NEC. 2. Check the HVAC and plumbing specifications for electrical requirements and include the same in the contract cost. 3. Equipment connections, starters, disconnect switches, control transformers and pushbutton stations for the equipment furnished by the owner or under a separate contract shall be installed and connected under this division, as indicated on the contract drawings. 4. All cutting, patching, excavating, backfilling and concrete work related to this contract will be the responsibility of the electrical contractor. This contractor shall assume the responsibility of providing the sleeves, chases and openings necessary for the electrical installation and for their repair in an acceptable manner, as determined by the architect. All holes shall be core -drilled. Provide fire stop in all openings created through fire -rated walls, floors or ceilings. 5. This contractor shall be responsible for providing all required access panels necessary for his work, coordinate with architect prior to installation. D. Materials and Workmanship 1. All work shall be installed in a practical and workmanlike manner, by mechanics skilled in the several trades necessary. 2. All materials shall be new and free from defects and shall be the best of their several kinds unless specified or indicated on the drawings to the contrary. 3. During each phase and at the completion of the construction, this contractor shall remove all debris and excess materials caused by his work. He shall leave the area of operation broom clean. 4. All electrical equipment shall bear the underwriters laboratories label or ETL label. 5. This contractor shall guarantee his workmanship and material (lamps excepted) for a period of one year from the date of building opening and leave his work in perfect order at the completion. Should defects develop within the guarantee period, the contractor shall, upon notice of the same, remedy the defects and have all damages to other work or furnishings caused by the repairs corrected at his expense to the condition before such damage. E. Scope of Work 1. The electrical contractor shall provide all labor, material, storage, unpacking and placement; to include but not be limited to, the following items: E.a. Emergency lighting and power. E.b. Complete power and Irghting distribution system including all panels, transformers and feeders. E.c. Complete branch circuit wiring system. E.d. Complete power wiring for all air conditioning equipment, plumbing system, heating equipment, ventilating and exhaust equipment. E.e. Complete lighting fixture installation, including all incandescent, fluorescent and HID lamps. E.f. Complete telephone and communication conduit and wiring system including boxes, plates, jacks, etc., as specified, shown on the drawings and required by the local telephone company and/or owner. E.g. Temporary electrical power and lighting as required for construction. E.h. Testing of all cables and circuit wiring after installation. E.i. Exit light system. E.j. Wiring devices and floor boxes. E.k. Lighting controls. E.I. Grounding of the electrical system. E.m. Fire alarm system. E.n. Telephone and electric services. E.o. Sound system components, conduit system & wiring. E.p. Complete conduit system for security devices, including pull string. F. Temporary Service 1. The electrical contractor shall furnish, install and remove as required all temporary power and temporary lighting in all areas and individual rooms when needed by the individual trades in the performance of their work. This contractor shall provide a minimum of twenty (20) footcandles of illumination for temporary lighting. Any additional lighting required by individual trades shall be provided by the individual trades including power for the lighting. The electrical work for construction purposes shall conform to all federal (OSHA), state, specific safety requirements, as well as the requirements of the national electric code and national electrical safety code. The electrical contractor shall obtain and pay for all required applications, permits and inspections pertaining to this work. This cost shall be included in the contractor's price. 2. New light fixtures shall not be used for temporary lighting. G. Electric Service 1. Provide metering to power company specifications. 2. Pay the cost of all power company charges connected with permanent electric service to the building. 3. Coordinate all work with the power company and perform any work necessary to assure a complete, working installation. The entire service . installation shall be in complete conformance with the power company's requirements. Section 16060 - Groundina and Bonding. A. Ground all equipment per N.E.C. B. Ground all dry type transformers as per drawings and NEC #450-10. C. All conduits shall contain a code -sized ground wire size per N.E.C. in addition to operating handle. the conductors shown on the plans. Where circuit conductors are increased in Safety switches shall be rated for 240 or 600 volts size for voltage drop, the ground wire size shall be increased proportionately. D. Where an isolated, insulated ground is required a separate isolated green ground 29110 Inkster Road shall be run from the panel isolated ground bus to the isolated ground connection Safety switches shall be fusible or non -fusible 2, of the device served. In no case shall the system ground (green wire and 248 355 0890 associated outlet boxes, conduit and building steel) be allowed to contact the °®� opj'�'` r.�„a isolate ground (green wire with white stripe). Safety switches shall be single throw unless otherwise indicated on Section 16120 - Wiring and Cable E. A. Color code conductors (except control and instrumentation conductors) as follows: otherwise 208/120 480/277 ®W_<g System System Manufacturer shall be Square D, Siemens, G.E., or Phase A Black Brown Q Phase B Red Orange Phase C Blue Yellow o -Ili V Neutral White Grey � 0 Ground Green Green 1. #12 and #10 conductors shall have continuous insulation color, as listed above. 2. Color code conductors larger than above, which do not have continuous insulation color by application of at least two lops of colored tape on each conductor at all points of access including junction boxes. Color tape shall be the equal of 3M products Scotch #35. 3. Conductors shall be soft annealed copper insulated for 600 volts unless specifically indicated otherwise. Aluminum conductors are not allowed on this project. B. Insulation type shall be type THWN for wire sizes #8 AWG and larger and THHN or THWN for #10 AWG and smaller. THHN shall not be used in wet or damp locations. C. Flexible cord shall be heavy duty type so with an equipment ground conductor in addition to the current carrying conductors. D. Provide #12 conductors, unless otherwise indicated. 1. Control conductors shall be #14 minimum for NEC class I and #16 for NEC class Il. E. Conductors #8 AWG and larger shall be stranded. F. Conductors #10 AWG and smaller shall be solid. Section 16120 (cont.) G. Install wiring in conduit. H. Connect #10 and smaller wires with constant pressure expandable spring type connectors, "Scotchlok" by 3M or B -Cap by Buchanan. I. Connect #8 and larger wires with compression connectors or splices as manufactured by Burndy or T&B. J. Insulate splicing connectors to at least 200% of the wire insulation. Use pre -stretched tubing connector insulators, 3M PST for #2 and larger conductors. K. Pull conductors using recognized methods and equipment leaving at least 6" wire at all junction boxes for connections. 1. Clean out each conduit system before pulling wire. L. Form and tie all wiring in panelboards. M. There shall be no wirenut joints or splices made inside switchboards/panelboards. N. Branch circuit wire sizes (and conduits) shall be increased from those indicated on the plans to prevent excessive voltage drop. Branch circuits shall be installed with wires of sufficient size so that voltage drop between the panel and the loads does not exceed limit of 3%. 0. Regardless of the temperature rating of the conductor insulation, all conductor ampacity rating for this project shall be determined from the 75'C conductor temperature ratings indicated in the NEC tables. Where equipment or devices are provided with terminals/lugs rated for 60'C, the ampacity rating of the 75'C conductor shall be limited to its associated 60'C rating as indicated in the NEC tables'. The electrical contractor shall be responsible to increase the conductors and conduit size as required. P. Circuits may be multi-plexed in conduit provided wire is properly derated and conduit sized per code. Under no circumstances shall more than six (6) current carrying conductors be run in a single conduit. Q. Provide wire and raceway systems as described herein and indicated on drawings. Metal clad (MC), armored cable (AC), and non-metallic sheated cable (NMC) shall not be permitted. unless noted specifically otherwise and approved prior to bidding. Section 16130 _Raceways aid Boxes A. Raceways 1. All wire shall be run in accordance with code in corrosion resistant, rigid, threaded, metal conduit or electrical metallic tubing (E.M.T.) unless otherwise specifically stated herein. A.a. Conduit in exterior walls, below floor slab, or underground shall be rigid, threaded, galvanized, heavy wall type. A.b. Carlon PVC type 40 heavy wall conduit with ground wire may be used below floor slab or underground in lieu of rigid, threaded, galvanized conduit. PVC 40 conduit shall not be run in or above floor slab. PVC conduit shall terminate below floor slab with rigid, threaded metal conduit adapter. Conduit above slab shall be metal. A.c. Conduit run exposed to the weather shall be heavy wall, metal threaded type. 2. Conduit size shall be 3/4" minimum. 3. Conduit shall be securely fastened in place. 4. All conduit shall be concealed in walls, floor and ceilings wherever possible. Exposed conduit in finished areas will not be permitted. Exposed conduit will be permitted in the unfinished areas with the specific approval of the architect, 5. Use flexible conduit for the connection to recessed or semi -recessed lighting fixtures (6' length maximum). Use liquid tight metal conduit for all connections to motors and other equipment subject to vibration and in areas subject to moisture. 6. Use watertight joints with buried and concrete encased conduit. All buried conduits outside of buildings shall have a minimum of 24" of cover. Metal conduits buried in earth shall be painted (two coats) with heavy asphaltum point. 7. Support runs of conduit as detailed in the appropriate table of the national electrical code (NEC). 8. Installed exposed runs of conduit and conduit above lay -in ceilings parallel or perpendicular to the walls, structural members of intersections of vertical planes and ceilings. Provide right angle turns using fittings or symmetrical bends. Support conduits within 1" of all changes in direction. 9. If a conduit is suspended, it shall be supported on trapeze hangers which use "all -thread" rods from the structural steel. The use of ceiling support wire or similar material will not be accepted. 10. Install empty conduit for future use as indicated on the drawings. Conduit shall be complete with jetline or pull rope, junction/outlet boxes, tile rings and appropriate cover plates. 11. Provide pitchpockets where conduits penetrate the roof. 12. Thread lubrication/sealant is required on outdoor and underground threaded metal joints. 13. Install fire seal fittings where conduits penetrate concrete floor slabs or masonry walls required to be fire rated. 14. Horizontal portion of conduit exposed on the roof and feeding equipment shall not be more than 5'-0" unless the written approval from architect or engineer is obtained. B. Pull and Junction Boxes 1. Install pull and junction boxes where shown on the drawings, and where required for changes in direction, at junction points, and to facilitate wire pulling. Furnish box sizes in accordance with NEC unless larger boxes are indicated. 2. Provide steel boxes and removable covers of code gouge, hot rolled sheet steel, hot dipped galvanized inside and outside, for above ground work. Furnish weatherproof boxes when installed above ground outside. 3. Provide cast iron boxes, hot dipped galvanized inside and outside where shown on the drawings. Furnish removable covers with gaskets and stainless steel, brass or bronze screws. 4. Provide concrete boxes for underground work unless otherwise indicated on the drawings. Furnish steel frames and covers with the cover attached to the frame with hexagon head, brass or bronze cap screws, 3/8" in diameter. Provide a rubber gasket for sealing between the cover and the frame. Paint the cover with two coats of heavy asphaltum. C. Outlet Boxes 1. Use sheet steel boxes, zinc coated or cadmium plated, for concealed interior work. 2. Use cast boxes, zinc -cadmium finish malleable iron, for exposed interior work, and for exposed or concealed work in wet, damp or exterior locations. Cast boxes shall be series FD by Crouse Hinds or Appleton. 3. Wall box sizes (minimum) shall be 4" square X 2-1/2" deep where wall construction permits. Where wall construction dictates, the width may be reduced to 2-1/8" or 1-1/2" under special conditions. 4. Fixture outlets in ceilings (minimum) shall be 4" octagonal X 1-1/2" deep (4-11/16" octagonal X 2-1/2" deep where required to accommodate larger conduit or larger number of wires). 5. Gang boxes shall be one piece (minimum), 2-1/8" deep. 6. Provide flush floor box series 880 by Wiremold with duplex receptacle for wood platform at display show windows, box with coverplate flange catalog #88OW1-818TCAL, and brushed aluminum coverplate catalog #828R-TCAL with flip lid to protect receptacle when not in use. Both flange and coverplate shall have brushed aluminum finish. UL scrub listed. 7. Flush mount boxes in all finished walls, install the plaster rings in drywalled plastered walls and raised covers as required in walls with other finishes so that the cover plates fit tightly against boxes or rings, 3/16" maximum gaps are allowed for noncombustible walls. 8. Adjust location of outlets in masonry or tile construction to occur in the nearest joint to the height specified. Heights shall meet A.D.A. requirements. 9. Support all boxes to maintain proper alignment and rigidity. 10. Clean boxes of all foreign matter prior to the installation or wiring of devices. 11. Mounting heights on the drawings are to the centerline of the box unless otherwise noted. Section 16140 -- Wiring Devices A. Wiring device color shall be selected by architect, unless otherwise indicated. B. Provide totally enclosed, 20 ampere, 120/277 volt, quiet A/C general use snap switches. C. Switches shall be specification grade as manufactured by Hubbel, P&S, or Leviton. D. Provide NEMA configuration 5-20R Duplex 125 volt grounding type receptacles rated for 20 amperes unless otherwise indicated on the drawings. E. Receptacles shall be specification grade as manufactured by Hubbell, P&S or Leviton. F. Receptacles requiring amperages, voltages or configurations different from the duplex convenience receptacles above shall be as indicated on the drawings. G. Provide other receptacles of a quality, material and workmanship equal to that specified for duplex convenience receptacles. H. Provide cover or device plates for outlet boxes as follows unless otherwise noted: 1. Finished areas: thermoplastic - color to match device. 2. Unfinished areas: zinc coated sheet metal, aluminum, or cast metal as appropriate for the type of box. 3. Exterior areas: copper free aluminum with gray, powder epoxy finish, gasket, weatherproof, Crouse -Hinds "WLRD" for duplex receptacles and WLRS for single receptacles or equal. 4. Telephone, communication, and signal outlet plates, shall match those used for receptacles and switches. All outlet and/or junction boxes shall be complete with a cover plate by this contractor. 5. Where devices are ganged, they shall be installed under a common coverplate. I. Locate the switches approximately 4'-O" above the finished floor elevation or nearest block course (within A.D.A. requirements), unless otherwise indicated. The long dimension of the switches shall be vertical Section 16140 (cont.) J. Locate receptacles approximately 1'-6" above the finished floor elevation or nearest block course (within A.D.A. requirements), unless noted otherwise. The long dimension of receptacles shall be vertical. Section 16410 - Safety Switches A. Safety switches shall be the enclosed heavy-duty type (type HD) with quick -make, E13:0007857 quick -break mechanism and external pad lockable operating handle. ❑ design deo. B. Safety switches shall be rated for 240 or 600 volts as applicable. They shall be JGA w horsepower rated when used in motor circuits. 29110 Inkster Road 11 C. Safety switches shall be fusible or non -fusible 2, 3, or 4 pole as indicated on 248 355 0890 the drawings. 248 355 0895 Fax °®� opj'�'` r.�„a D. Safety switches shall be single throw unless otherwise indicated on the drawings. E. Enclosures shall be NEMA 1 indoors and NEMA 3R outdoors unless otherwise m indicated on the drawings. ®W_<g F. Manufacturer shall be Square D, Siemens, G.E., or Cutler -Hammer. All safety Q switches shall be by one manufacturer. G. Mount the safety switches securely between 3' X 6' levels above the floor unless otherwise indicated on the drawings. H. Switches on block walls shall be mounted on a 3/4" plywood backboard, where located indoors. Section 16420 - Motor Starters A. Provide motor starters (magnetic or fused combination) and control equipment where shown. Starters shall be provided with 120 volt coils, 3 overloads, control transformer with fused 120 volt secondary control circuit, (2) N.O. and (2) N.C. auxiliary contacts, hand -off -auto selector switch and running pilot light, unless otherwise noted. Wire thru control devices furnished by other trades. Since motor driven equipment is furnished by other trades, the control indicated on the drawings shall be considered as for bidding purposes only. Wire to conform to the actual equipment supplied and installed by the other trades. All fuses shall be dual element type. Provide "blownfuse" indicator lamps in cover. B. Starters shall be Square D, G.E., Cutler -Hammer, or Siemens. C. The exact number of normally open and normally close auxiliary contacts in each starter shall be determined by the temperature control contractor. . D. Coordinate all equipment indicated on the electrical drawings with mechanical equipment schedules and specifications and provide motor starters for all equipment indicated as being interlocked or started from a remote location. E. Starters supplied as an integral part of equipment shall be furnished under the division providing the equipment. Wiring and disconnect shall be by this contractor. All other starters and auxiliary control equipment shall be supplied and wired by this contractor unless otherwise noted. aggtion 16442 - Distribution and Panelboards A. Web enabled lighting control system - General 1. Introduction The work covered in this section is subject to all the requirements in the general conditions of the specifications. The contractor shall coordinate all of the work in this section with all of the trades covered in other sections of the specification to provide a complete and operable system. 2. Description of the work a. The extent of the lighting control system work is indicated by the drawings and by the requirements of this section. It is defined to include, but not by way of limitation: 2.1. Panelboards containing both standard and remotely operable circuit breakers. 2.2. Control electronics for switching circuit breakers and monitoring the status of the system. 2.3. Associated low voltage key switches and light sensors. 2.4. Any work stations, software and communications hardware. b. System installation includes the following: 2.1. Wiring of main and branch circuit conductors. 2.2. Installation of external control devices and wiring to the panelboard controller. 2.3. Installation of communications conductors and associated hardware. 3. Warranty a. Manufacturer shall warrant specified equipment to be free from defects in materials and workmanship for at least one year from the date of installation or eighteen months from date of purchase. 4. Equipment a. Equipment shall be Square D Powerlink G3 System, Contact "H&M b. Materials and Components 4.1. Integrated lighting control system A.a. The lighting control system shall consist of microprocessor -based control electronics with remotely operated circuit breakers mounted to a UL67 listed lighting panelboard interior and enclosed in a UL50 listed panelboard enclosure. The circuit breakers shall provide overcurrent protection, and have an air rating or series connected rating that meets or exceeds the fault current of the system to which the panelboard is being applied. A.b. Each master control panel shall meet or exceed the following capabilities: 1) Sixteen (16) 2 -wire input terminals for connection to external low voltage switch contacts. 2) Remote control of 168 branch circuits in a master/slave configuration. 3) Provide true status feedback by monitoring branch circuit breaker status based on actual system voltage of load side terminal. 4) Accept remote commands through the facilities ethernet infrastructure. A.c. All lighting control components shall be installed in a conventional panelboard 20 inches wide or column -width enclosures (as noted on drawings). Suitable barriers shall be installed to separate class 2 wiring from power conductors. 4.2. Hardware A.a. To minimize space requirements, the remotely operated circuit breakers and electronics shall be integral to the lighting ponelboard. A.b. Remotely operated circuit breakers - all remote branch circuit breakers shall provide overload and short circuit protection suitable for the location in the electrical system, as defined in the panelboard schedules. Remotely operated power switching devices shall have the following: 1) Integral branch circuit overcurrent protection as required by the National Electrical Code (NEC). All circuit breakers shall have a UL listed interrupting rating sufficient for the application or shall have UL listed series connected ratings for the maximum available fault current at that point in the system. Submittals reflecting the use of relays or contactors to perform remote switching must show evidence in writing that the relay can safely withstand the available fault current. 2) UL listed SWD ratings for 15A and 20A 1-, 2- and 3 -pole branch devices, HID ratings and HACR ratings. 3) Handle operator that shall mechanically open the power switching device contacts when moved to the off position and disable the contacts from being remotely closed. 4) Manual override switch to enable or disable the remote operation of the device and allow breaker handle to fully control the on/off state of the breaker. Override must fully disengage remote operation of the breaker mechanism. Device utilizing 'one-shot' or 'temporary' overrides will not be accepted. 5) Visible flag that clearly indicates the status of the circuit breaker contacts with the panel trim installed, flag shall indicate: on, off, and tripped circuit breaker states. The visible flag shall be mechanical in nature, directly tied to the circuit breaker mechanism, and shall be provided in addition to any status indicator supplied by the system electronics. 6) Switching endurance rating of 200,000 open/close/open remote operations, switching devices with lower ratings may be judged to be acceptable, but must be provided with (100%) (200%) spare switching devices for each circuit to ensure an equivalent total number of operations. c. Lighting Control Electronics - Master Panelboards Section 16442 (cont.) 4.1. Panels identified on the panel schedule as master panels shall contain both a power supply module and controller in the indicated spaces. Master panels provide power and control for operating and monitoring remotely operated branch circuit breakers connected to control busses located in master and slave panelboards. One power supply module and controller shall support up to eight (8) control busses. 4.2. Master panels shall contain a nameplate label, located on the panel trim indicating its designation, automation level network address, and the designations and addresses of all associated slave panels. . 4.3. A power supply module shall be furnished to provide control power for the operation of the remotely operated circuit breaker, controller, bus system and low voltage inputs. Power module(s) shall connect directly to the panel interior and receive line voltage from the panel bus. Power module(s) shall be internally self -protected and operate within a range of -15% to +10% of its normal line voltage rating. 4.4. The controller shall operate whenever voltage is within the power supply operating range. In the event of incoming power outage, the controller shall automatically halt execution in a safe manner. Upon return of power, the controller shall automatically reboot and return to normal system operation. 4.5. The controller shall include the following: A.a. Integral keypad and LCD front panel for local setup, front panel setup shall permit local input setup and creation of time schedules without requiring separate PC-based software or hand-held loader devices. A.b. RS232 serial communications interface to permit local connection to personal computer without having to remove panel trim. A.c. Non-volatile memory to retain all setup and configurations. A.d. Sixteen terminals configurable for either sixteen (16) two -wire inputs, eight (8) three -wire inputs, or eight (8) two -wire inputs with status feedback for pilot LED's. All configurations shall allow either momentary or maintained control devices to be attached without providing any external control power. A.e. An auxiliary control power source for powering external control devices such as occupancy sensors and low voltage photo sensors, as indicated on drawings. A.f. Programmable input timers to permit timed override periods. A.g. Adjustable blink notice. A.h. Ability to log and display remotely operated breaker on-time. AJ, Ability to log events including changes to breaker state, input state, zone state, schedule periods, and bus operational status. A.j. Means for setting initial ethernet parameters via a local operator interface without having to employ special software or configuration tools. A.k. Capability for accepting downloadable firmware so that the latest production features may be added in the future without replacing the module. 4.6. Time scheduler shall provide, at minimum, the following: A.a. Sixteen (16) independent schedules, each having twenty-four (24) time periods. A.b. Clock configurable for 12 -hour (AM/PM) or 24-hour format. A.c. Schedule periods settable to the minute. A.d. 365 -day calendar, with automatic daylight savings and -leap year adjustments. A.e. Day -of -week, day -of -month, day -of -year with one-time or repeating capability. A.f. Thirty-two (32) special date periods with ability to nest different periods within other periods. A.g. Astronomical tracker to automatically adjust sunrise and sunset times throughout the year. 4.7. Controller inputs shall be connected to external devices as shown on the drawings. Controller inputs shall be configured according to the customer's requirements and shall be capable of providing the following capabilities: A.a. Configurable for normally open, normally closed, 2 -wire maintained toggle, 2 -wire momentary toggle, 2 -wire momentary on, 2 -wire momentary off, or 3 -wire momentary operation. A.b. Inputs shall also be capable of operating in conjunction with a building automation system to provide blink notice operation. A.c. Capable of assigning timers to inputs for local override operation. Timers type shall include a timed on and off -delay capabilities. The increments shall be settable between 5 minutes to 18 hours. A.d. An input synchronization service shall be provided to synch inputs with other inputs, zones, time schedules, or remote sources. This synchronization service shall be used to control input state, input inhibit mode (enable/disable), or sync timers (enable/disable). 4.8. Panel controllers shall have the capability of configuring either local or remote sources in an "and", "or", or "last event" configuration. Sources shall include, but not limited to, inputs, time schedules, or status. Up to four sources shall be permitted in a custom configurable logic arrangement. 4.9. Zone priorities shall be assignable to each zone such that the particular zone shall have priority over other zones. Zone priorities shall be capable of forcing all breakers in the zone to an on state or an off state depending on the particular configuration. 4.10. Each Panel controller shall have the capability of communicating to another panel controller in a peer-to-peer configuration. A.o. Each input connected to the controller shall be capable of controlling any branch circuit connected to any other controller. A.b. A schedule programmed in one controller shall be capable of controlling any branch circuit connected to any other controller. 4.11. Panel controllers shall incorporate a web -enabled server for displaying information over a standard web browser. Web -accessible information shall include: A.a. A secure, password protected login screen for modifying operation parameters to ensure only authorized access. Password administration shall be accessible to authorized users via web page interface. A.b. Separate web pages for each panel with the arrangement of breakers on the page matching the physical appearance of the panel. Panel status pages shall also include breaker nametags, pole configuration, location in panel, and actual contact state (on/off/tripped/manual) for the master panel and each associated slave panel. The web page shall also provide the ability to observe breaker on-time and blink information in real time. A.c. Panel summary showing panels connected to the controller. A.d. Controller summary showing controller diagnostic information. A.e. For a consistent user interface provide remote front panel mimic screens for setting up controller parameters, input types, zones, and operating schedules, mimic screens shall also allow direct breaker control and zone overrides. A.f. The user interface shall share a common "look and feel" between panels and other web -enabled distribution equipment. 4.12. Each master controller shall incorporate an alarm and 1. automated e-mail notification service. These services shall be capable of automatically initiating alarms based on preconfigured conditions and routing alarm alerts as directed by the customer. Customer shall furnish a list of alarms to be configured and e-mail addresses to receive each alarm. A.a. Alarms shall be configurable for the following para meters: 1) Global alarms: power loss, non -responding breakers, loss and restoration of sub -net communications, loss and restoration of serial port communications, loss and restoration of modbus top ethernet 2) Specific alarms: input status, zone status, breaker status on-time (0 to 99999 hours). A.b. E-mail notification service shall include the ability ®1_� ®® THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA Lh8 355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: I I I -(-� �T aw�"(o JEFFERY D. MITERKO PE: 0051703 ❑ programming E13:0007857 schematic des. Expires: 2/28/11 ❑ design deo. Consultants: LU RETAIL DESIGN CONSULTANT N permits JGA w ❑ construction 29110 Inkster Road 11 Suite 200 � Southfield, MI 48034 USA REVISIONS: 248 355 0890 248 355 0895 Fax °®� opj'�'` r.�„a www.jga.carrt JGA Prj #: 1-209-057 . 4 N9 ❑ programming TBA schematic des. C) ❑ design deo. JDM LU U N permits U) ❑ construction ® landlord prelim. CID � � 02.27.0q REVISIONS: W " XLa --I W _ V m % ®W_<g - }w- Q � LU o -Ili V U - � 0 0 0 � W 1 � t-- Ow LL,L. g Q O a_ U) cv W }- DRAWINGS ISSUED FOR: ❑ programming TBA schematic des. 02.Oq.Oq ❑ design deo. JDM ❑ bidding N permits 03.12.Oq ❑ construction ® landlord prelim. 02.Oq.Oq ® landlord final 02.27.0q REVISIONS: Prj. no. 8-209-012 Drawn TBA Checked JDN Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: ELECTRICAL SPECIFICATIONS Sheet no. ARIMM AMM tb*1 E 12 N E 0 N r- .y 0 n iv a `r N L; W 6 LdO O 0 1 0 U cA E 0 Z m i 0 F__ ELECTRICAL SPECIFICATIONS (cont.) Section 16442 (cont.) to automatically route an e-mail message to five individual e-mail addresses. 4.13. Each panel controller shall incorporate a time synchronization service to update controller clock to a network time server. Time serve shall incorporate both a primary and secondary source. Update interval shall be setable from 1 to 24 hours. A.a. Lighting control electronics - slave panels 1) Panels marked as slave panels shall contain the necessary busses and network hardware to allow connection of the sub -net wiring between panels. 2) Sub -net wiring connections shall allow connection of wiring to a terminal that can be removed from the panel without interrupting the communications to other panels. 3) Slave panels shall contain a nameplate label attached to the dead front trim indicating the panel designation, network address of the panel, and the panel designation of the associated master panel. 4.14. Networks A.a. Installation of additional special purpose networks shall be minimized by using the existing facility ethernet LAN to connect to various lighting panels or groups of lighting panels as shown on the drawings. Equipment shall be compatible with industry standard TCP/IP protocols. . A.b. Power monitoring metering devices as shown on the drawings shall connect using the some network as the lighting control panels. Power monitoring data shall be shown on the same browser based graphical user interface screens as the lighting information. A.c. Provide sub -net wiring between master and slave panels as indicated on the drawings. Sub -net wiring shall permit slave panels to receive power and control data from the master panelboard no more than eight (8) bus rails shall be connected to the sub -net. A.d. Sub -net communications shall follow class 1 wiring practices. Communications conductors shall be Belden 27326 of equal having the same voltage rating as the branch circuit conductors. Wiring distances shall not exceed the manufacturer's recommendations. A.e. Communications wiring to master panels shall use shielded category 5e cabling. Installing contractor shall coordinate work with the network administrator to assure that proper connection points are available. The installing contractor shall also secure one static IP address for each master controller. 4.15. Configuration Software A.a. Configuration software shall be designed specifically for the lighting control system and supported by the manufacturer. Software shall support system configuration and monitoring and control functions in a windows environment. A.b. For basic setup and control, the software shall serve as a configuration and diagnostic utility, basic features shall include support for configuring inputs, zones, circuit breaker actions, and time schedules. Software shall be able to monitor the status of the system and provide visual indication of input status, circuit breaker status, and operational parameters, software shall be able to establish connections to the system through a controller front port, RS232 port, RS485 port, and ethernet port support for remote. A.c. Square D shall supply H&M with a licensure document to be held by H&M's it department to allow multiple copies of their Powerlink software to be legally loaded and run from multiple workstations. 4.16. Services A.a. Custornization 1) Manufacturer shall provide any custom hardware or communication devices necessary to make the system perform as specified above. 2) Manufacturer shall provide PC user interface custom screens rough layouts of the screens will be provided to the manufacturer no less than 30 days before scheduled system start-up. A.b. Start-up 1) Manufacturer shall provide on-site services to confirm correct communications wiring in the field, initiate communications between panels and program the lighting control system. The electrical contractor shall provide zone configuration schedules, time -of -day schedules, and input override assignments to be used in programming to the manufacturer no less than 14 days before planned system start-up. 2) Manufacturer shall provide one day of on --site training during the start-up period. B. Panelboards 1. Panelboards shall be enclosed dead front safety type with features and ratings as scheduled on the drawings. 2. Panels known as "load centers" are unacceptable. 3. Molded case circuit breakers shall be as scheduled on the drawings and specified in this division. 4. All bus bars shall be rectangular, solid copper. 5. Space, where shown in panel schedules, designates space for future protective devices and shall include bus and support. 6. Install cabinets so that center of the top breaker does not exceed 6'-6" above the finished floor. 7. Entries on directory cards shall be typed, complete and accurate. 8. All bolted connections shall be torqued in accordance with manufacturer's standards. 9. Electrical contractor shall arrange circuits as near as possible to circuit numbers on the drawings. At completion of job, electrical contractor shall take current reading checks of respective phases. A minimum of circuit connections shall be rearranged to balance as closely as possible, the load in the panel 10. All breakers shall be bolt -on type. 11. Provide (3) spare 1" conduits into accessible ceiling space where panels are flush -mounted. C. Distribution Panels 1. Distribution panels shall be dead front type with features and rating as scheduled on the drawings. 2. Molded case circuit breakers shall be as scheduled, of size and number indicated on the drawings. All breakers shall be bolt -on type. 3. All lugs shall be UL approved CU/AL type. 4. Panels shall be manufactured as a complete unit and not an assembly of parts secured from a supply house. 5. All panels shall be capable of accepting circuit breakers sized up to and including 400 amps. 6. Vertical bussing shall be extended the full length of the panel. 7. All bus bars shall be rectangular solid copper. 8. Distribution panels shall be Square D. 9. Install panels such that handle for the top breaker does not exceed 6'-6" above finished floor. 10. Provide phenolic labels for each panel. 11. All bolted connections shall be torqued in accordance with manufacturer's standards. 12. Surface -mounted panels shall be mounted on a 3/4" plywood backboard. Floor -mounted panels shall be mounted on a 4" high concrete pad. Section 16461 - Dry Type Transformers A. Transformers shall be continuously rated isolating type for 60 hertz service unless otherwise indicated. B. Insulation systems shall be 220 degrees C (150 degrees rise). C. Enclosures for transformers shall be metallic, suitable for indoor and outdoor installation as applicable and rodent proof. D. Manufacturers shall be Square D. Fractional KVA transformers shall be manufactured by Edwards or the special equipment manufacturer in which the transformers are used. E. Four approved vibration dampeners per transformer shall be employed as necessary to avoid transmitting any vibration to the building structure. Sizes of the mountings shall be selected on the basis of the weight of the transformer, using: 1. A minimum 1" thick rubber -cork -rubber sandwich type for floor mounting. 2. A spring type for suspension mounting. 3. Two(2) spring type at the top (with two (2) steel brackets) and two (2) rubber -in compression type at the bottom (stand-off) for wall mounting. Section 16461 (cont.) F. No conduits shall be attached directly to the transformer. At each attachment, provide a vibration dampening assembly consisting of: 1. AT&B #5721, 2, 3 etc., or equivalent female hub type liquid -tight connector by Steel City, Efcor or approved equal. 2. T&B #5331, 2, 3 etc., or equivalent male hub type liquid -tight connector with an insulated throat by Steel City, Efcor or approved equal. 3. Short length (24" plus or minus) of liquid -tight flexible conduit. 4. A bonding jumper of NEC size outside of the assembly. G. Floor mounting: all floor mounted transformers shall be installed on a 4" high concrete pad. This contractor shall furnish and install concrete pad. Section 16491 - Fuses A. The contractor shall furnish a complete set of fuses for all switches, plus fusible equipment furnished by other trades. Unless indicated otherwise on plans, the fuses shall be of the following types: 1. Fuses 601 to 6000 amps shall be UL class. Trade type shall be KRP-C as manufactured by the Bussmann Company. 2. Fuses 1/10 to 600 amps shall be UL class RK1. Trade type shall be low peak LPS-RK (60OV) and LPN -RK (25OV) as manufactured by the Bussmann Company. 3. All other fuses shall be dual -element current -limiting type with 200,000 amperes symmetrical interrupting capacity. B. Fuses shall be manufactured by Bussmann, Gould-Showmutt, or Reliance. C. Spare fuses amounting to a duplicate set of each size installed shall be turned _ over to the owner upon completion of the project. Provide and place in a spare fuse cabinet similar to Bussmann # SFC. D. This contractor shall replace all fuses blown during construction. Section 16511 - Lightinc�__Fi_xtures A. Linear fluorescent lamps for new light fixtures shall be Philips only, 3000K color temperature. B. Lighting fixtures and lamps shall be furnished and installed as indicated on the lighting fixture schedule. C. All fixtures furnished by the electrical contractor shall bear the underwriter's laboratories label, shall bear all required city of Chicago approvals (where applicable) and shall be installed according to manufacturer's instructions. D. Ballasts for linear fluorescent lamps shall be electronic, parallel, instant -start, normal output type, less than 10% THD, CBM and ETL certified, as manufactured by Magnetek, Motorola or Advance. E. This contractor shall provide and install all necessary support media for all lighting fixtures including structural steel, angle, rods, etc. In general, fluorescent and high intensity discharge fixtures shall be supported in a manner acceptable to the local inspection authorities. All fixtures shall be firmly supported from beams or joists. 1. Provide all necessary backing, blocking and supports for wall mounted fixtures. 2. Fixtures shall not be supported from roof deck. F. All fixtures shall be UL listed and approved for the purpose. G. Recessed fixtures in fire rated ceiling or supply air plenums shall be approved for the fire rating of the ceiling. Provide air -tight gaskets to seal around openings. H. All adjustable fixtures shall be aimed and adjusted during evening hours to the satisfaction of the architect and/or tenant. - Telephone System - Communications 0 System Conduit, Cabling and Equipment A. Summary 1. Section Includes: A.a. Wire, conduit, boxes, cable, connecting devices, installation, and testing for wiring systems to be used as signal pathways voice and high-speed data transmission. . A.b. Make provisions to provide extension of high speed data connection. Smart jack by Telco to tenant space. A.c. Review responsibility schedule on last sheet of specifications A.d. Review dgtg, cable matrices notes for data conduit fill on Igat met_ of_ st.ecifi_cations, B. Definitions 1. EMI: Electromagnetic Interference 2. IDC: Insulation Displacement Connector 3. LAN: Local Area Network 4. PVC: Polyvinyl Chloride 5. UTP: Unshielded Twisted Pair C. Quality Assurance 1. Technology installer (T.C.) qualifications: an experienced installer who is a Bisci registered technician level II installer. 2. Comply with NEPA 70, EIA/TIA 566. 3. Electrical components, devices, and accessories: listed and labeled as defined in NEPA 70, article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. D. Coordination 1. Coordinate work of this section with owner's telephone switch, telephone instrument, workstation, and LAN equipment suppliers. D.a. Adjust arrangements and locations of distribution frames, patch panels, and cross connects in equipment rooms and wiring closets to accommodate and optimize arrangement and space requirements of telephone switch and LAN equipment. D.b. Refer to H&M supplied "US/CA Standard Store It Department Specifications", version 7.0, updated 25 March, 2008 for additional information for coordination. D.c. Technology contractor shall coordinate installation of high-speed data connection with service provider to allow all equipment to be installed in tenant space. D.d. Technology contractor will make all cross connections needed to extend the data connection from the building demark to tenant demark before installation of high-speed data service. D.e. Telephone/Data conduit system E. Electrical contractor to provide telephone service conduit or duct to telephone board as shown on plans. Conduit shall be rigid or EMT. Flex or Greenfield is not permitted. There shall be easy access to all pull box locations if there are more than 3 bends. EC must notify the TC in writing, the exact length of the conduit, how many bends there are, provide them with a map of the bends. EC must verify with mall and local Telco provider which telephone room location to run the conduit from to H&M's space. The EC shall verify all conduit runs are no longer than 290'-0". 1. The electrical contractor shall provide and install all conduit and outlet boxes for technology cabling. 2. The technology contractor shall provide and install all 25 pair and CAT5E cable, data and phone jacks, face plates, patch panels, technology cabinet and miscellaneous equipment to meet the specifications. 3. EC shall provide plywood terminal board as shown on drawings. 4. A conduit run shall have no more than three (3) bends in a run between outlet boxes or between outlet box and a metal cabinet or pull box. When a run requires more than three (3) bends, a pull box of suitable size shall be placed in a suitable location to meet the above conditions. Daisy chaining or bending behind walls is absolutely not permitted. 5. All telephone and data cabling shall be in conduit Conduit shall be continuous from device to data rack in LAN room. Conduit shall meet fill requirements as indicated in the table at the end of the specifications. 6. Pull -strings must be placed in all conduit by EC and TC must run new pull -strings through conduit along with cables for future expansion capabilities. F. Manufacturers - Approved Manufacturers 1. Cable: F.a. Belden Wire & Cable Company (317-983-5200) F. b. Essex Group, Inc.; Telecommunications Products Division (214-461-4000) F.c. General Cable (908-769-3200) F.d. Mohawk/CDT (800-422-9661) 2. Terminal and connector components and patch panels: F.a. Manufacturers as listed below in 16740.H.2.H.a only. No substitutions permitted. G. System Requirements 1. General: coordinate the features of materials and equipment so they form an integrated system. Match components and interconnections for optimum future performance. 2. Expansion capability: unless otherwise indicated, provide conductor pairs in cables, positions in patch panels, cross connects, and terminal strips, and space in backbone cable trays and wireways to accommodate 50 percent future increase in active station pairs. H. Mounting Elements 1. Backboards: 3/4 -inch interior -grade, fire -resistive -treated plywood. 2. Distribution rocks. floor -standing, two post network equipment rack designed for telecommunications terminal support and coordinated with dimensions of units to be supported. H.a. UL listed two post network equipment rack with 3" uprights and 19" rack width, Cooper B-line catalog #SB556KO84XUFB with grounding accessories, grounding kit and anchor. Section 16740 (cont.) No substitutions permitted Provide unit with the following accessories: Leviton: #41108-RW5 white cat 5 snap in jack #4108W-1 SP - single port wall mount face plate #41080-1WP - single port face plate #41080-2WP - double port face plate #41080-3WP triple port face plate #41080-4WP - quad port face plate #41080-6WP -six port face plate #49252 -PCM - combo front/rear manager panel #P1040 -10S - 120V vertical power strip - provide (2) total Hubbell: #P5E48UEW - white 48 port patch panel #P5E24UEW -- white 24 port patch panel #P5E24UE - black 24 port patch panel Panduit: #WMPV45E - 83" vertical wire manager Cooper B-line:#SB1712FB - flat black ladder rack #SB213212FB - rack to runway support #SB211312FB - wall angle bracket #SB5961915AAL 19" rack mount shelf 3. Finish: flat black powder coat. I. Twisted -Pair Cables, Connectors, and Terminal Equipment. 1. Listed as complying with categories 5 of EIA/TIA-568-B. Data ABND telephone branch cable shall be category 5e. 2. Conductors: solid copper. 3. UTP cable: comply with EIA/TIA-568-B. Four thermoplastic -insulated, individually twisted pairs of conductors; No. 24 AWG, color -coded; enclosed in PVC jacket. 4. UTP cable connecting hardware: comply with EIA/TIA-568-B. IDC type, using modules designed for punch -down caps or tools. I.a. IDC terminal block modules: integral with connector bodies, including plugs and jacks where indicated. 1. b. IDC connecting hardware: consistent throughout project. 5. Patch panels: modular panels housing multiple, numbered jack units with IDC -type connectors at each jack for permanent termination of pair groups of installed cables. La. Number of ports per field: 1) Patch panel "A" should be in two parts (1) 48 port panel, Hubbell #P5E48UEW, and (1) 24 port panel Hubbell #P5E24UEW, and patch "B" should be a 24 port panel, Hubbell #P5E24UE, in stores with 12 or less cash registers. If the store has more than 12 registers, patch panel "A" should be (2) 48 port panels. If the store has 24 or more registers patch panel "A" should be in three parts (2) 48 port panels and (1) 24 port panel plus one additional wire management rack, in all cases patch panel "B" will be a 24 port panel, #P5E24UE. I.b. Mounting: cabinet, 6. Jack and jack assemblies for data circuit UTP cable: modular, color -coded, RJ -45 receptacle units with integral IDC -type terminals. I.a. 1 port jack location, (1) Leviton #41108-RW5 w/ Leviton #41080-1WP face plate. 1. b. 2 port jack location, (2) Leviton 41108-RW5 w/ Leviton #41080-2WP face plate. I.c. 3 port jack location, (3) Leviton 41108-RW5 w/ Leviton #41080-3WP face plate. I.d. 4 port jack location, (4) Leviton 41108-RW5 w/ Leviton #41080-4WP face plate. Le. 6 port jack location, (6) Leviton 41108-RW5 w/ Leviton #41080-6WP face plate. I.f. Wall telephone location: (1) Leviton #41108-RW5 w/ Leviton #41080-1SP wall plate. I.g. Surface box for data ports at cashwraps: (1) Leviton #42777-1WA, 7. TC shall supply wire management racks for the data rack as described in 16740.H.2.H.a. Refer to H&M supplied "US/CA Standard Store It Department Specifications", version 7.0, updated 25 March - 2008 for additional information. J. Identification Products 1, Cable labels: self-adhesive vinyl or vinyl -cloth wrap around tape markers, machine printed with alphanumeric cable designations. 2. Brother P -touch (equivalent) with black on white labeling. 3. Handwritten labels are not permitted. K. Examination 1. Examine pathway elements intended for cable, check raceways, cable trays, and other elements for compliance with space allocations, installation tolerances, hazards to cable installation, and other conditions affecting installation. Proceed with installation only after unsatisfactory conditions have been corrected. L. Application of Media 1, Horizontal cables for data service: use UTP cable complying with category 5e of EIA/Tia-568-B for runs between wiring closets and workstation outlets. M. Installation 1. Wiring method: install wiring as described herein. Conceal wiring except in unfinished spaces. 2. Install cable using techniques, practices, and methods that are consistent with category 5e rating of components and that ensure category 5e performance of completed and linked signal paths, end-to-end. 3. Install cable without damaging conductors, shield, or jacket. 4. Do not bend cable in handling or in installing to smaller radii than minimums recommended by manufacturer. 5. Pull cables without exceeding cable manufacturer's recommended pulling tensions. M.a. Pull cables simultaneously if more than one is being installed in the same raceway. M. b. Use pulling compound or lubricant if necessary. Use compounds that will not damage conductor or insulation. M.c. Use pulling means, including fish tape, cable, rope, and basket -weave wire/cable grips, that will not damage media or raceway. 6. Wiring within wiring closets and enclosures: provide adequate length of conductors. Train conductors to terminal points with no excess. Use lacing bars to restrain cables, to prevent straining connections, and to prevent bending cables to smaller radii than minimums recommended by manufacturer. 7. Separation of wires: comply with EIA/TIA-569 rules for separating unshielded copper communication and data-processing equipment cables from potential EMI sources, including electrical power lines and equipment. 8. Make splices, taps, and terminations only at indicated outlets, terminals, and cross -connect and patch panels. 9. Use splice and tap connectors compatible with media types. 10. Install a pull wire in each and every empty conduit. 11. Each cable shall be terminated and labeled with the port number at panel A. 12. TC shall install a category 5 rated 25 -pair cable from the mall or building phone room and/or sub phone room to the telephone backboard in the electrical room beside the LAN cabinet, terminated to a fib -block on both ends. N. Grounding 1. Ground cable shields, drain conductors, and equipment to eliminate shock hazard and to minimize ground loops, common -mode returns, noise pick-up, cross talk, and other impairments. 2. Bond shields and drain conductors to ground at only one point in each circuit. 3. Signal ground terminal: locate in each equipment room and wiring closet. isolate from power system and equipment grounding. 4. Signal ground bus: mount on wall of main equipment room with stand-off insulators. 5. Signal ground backbone cable: extend from signal ground bus to signal ground terminal in each wiring closet and equipment room. 0. Installation in Equipment Rooms and Cabinets 1. Provide backboard as shown on the drawings. 2. Mount patch panels, terminal strips, and other connecting hardware in the specified cabinet. 3. Group connecting hardware for cables into separate logical fields. 4. Use patch panels to terminate cables entering the cabinet. P. Identification 1. Identify system components complying with applicable requirements in division 16, section 16075, electrical identification and the following specifications. 2. System: number the ports consecutively (e.g., 1, 2, 3 ... etc.). 3. Workstation: label cable port number on cable shielding within the outlet box. 4. Distribution racks and frames: consecutively label each unit and field within that unit. 5. Within connector fields, in wiring closets and equipment rooms: label each connector and each discrete unit of cable -terminating and connecting hardware. 6. Cables, general: label each cable within 4 inches to each termination and tap using all three listed identification products, where it is accessible in a cabinet or junction or outlet box, and elsewhere as indicated. 7. Exposed cables and cables in cable trays and wire troughs: label each cable at intervals not exceeding 15 feet. 8. Cable schedule: post in prominent location in each wiring closet and equipment room. List incoming and outcoming cables and their designations, origins, and destinations. Project with rigid frame and clear plastic cover. Provide electronic copy of final comprehensive schedules for project, in software and format selected by owner. Section 16740 (cont.) Q. Field Quality Control 1. The H&M IT representative retains the right to be present at any or all cable certification. The contractor shall provide written notice 48 hours prior to the beginning of the certification process. 2. Inspect the cables for damage prior to performing testing, if cable is damaged repull cable. 3. The contractor shall provide a copy of certification test reports to the engineer in both hardcopy and electronic format. Contractor shall also provide a copy of the cable tester's database management software. 4. Independent system certified testing may be required, at the discretion of the H&M IT department, provided at the expense of the contractor, in the event of non-performance of the specified testing procedures, submittals and/or installation procedures. 5. Data cable test reports Q.a. Upon completion of the cable installation, the contractor shall perform complete copper cable certification tests on every cable, included but not limited to: 1) For category 5e cabling and higher: Wire map Length Attenuation Near end cross talk (Next) Equal level for end cross talk (Elfext) Propagation delay and delay skew Return loss Q.b. Test shall be performed to published standards, including, but not limited to, the latest revisions of EIA/TIA 568, ISO/IEC 11802 and other applicable standards at the time of installation. . Q.c. All tests shall be performed with a certified test device. Q.d. Tester shall be factory calibrated each calendar year by the field test equipment manufacturer as stipulated by the manuals provided with the field test unit. The calibration certificate shall be provided, upon request, to the H&M IT department. Q.e. Auto test settings provided in the field tester for testing the installed cabling shall be set to the default parameters. Q.f. Test settings from options provided in the field testers shall be compatible with the installed cable under test. 6. Remove any malfunctioning cable, replace/repull with new cable and retest as specified above. R. Cleaning 1. After cornpleting system installation, including outlet fittings and devices, inspect exposed finish. Remove burrs, dirt, and construction debris and repair damaged finish, including chips, scratches, and abrasions. S. Demonstration 1. Engage a factory -authorized service representative to train owner's maintenance personnel to adjust, operate, and maintain systems. S.a. Train owner's maintenance personnel on procedures and schedules for starting and stopping, trouble -shooting, servicing, and maintaining equipment and schedules. 2. Train designated personnel in cable -plant management operations, including changing signal pathways for different workstations, rerouting signals in failed cables, and extending wiring to establish new workstation outlets. Section 16$00 - Fault Current Study A. The fault current study shall be performed by the distribution equipment manufacturer. The study shall be submitted to the engineer prior to receiving final approval of the distribution equipment shop drawings and/or prior to release of equipment for manufacture. If formal completion of the study may cause delay in equipment manufacture, approval from the engineer may be obtained for a preliminary submittal of sufficient study data to ensure that the selection of device ratings and characteristics will be satisfactory. B. The fault current study shall be performed with the aid of a "Windows95" based computer program. C. The input data shall include the power company's fault current contribution, resistance and reactance components of the branch impedances, the X/R ratios, base quantities selected and other source impedances. D. Short circuit momentary duty values and interrupting duty values shall be calculated on the basis of three phase bolted short circuits at each switchgear bus, switchboard, distribution panel, branch circuit panel, and other significant locations through the system. The short circuit tabulations shall include symmetrical fault currents and X/R ratios. For each fault location. the total duty on the bus, as well as the individual contribution from each connected branch, shall be listed with its respective X/R ratio. Section 16810 -- Sound-Ecl_ ipment (8W Solutions. DMX. ECI A. Sound equipment shall be furnished as follows: 1. BW Solutions - Speaker cabling and DJ cabling by electrical contractor per Bose requirements. Contact Ben Noury at BW Solutions (619) 241-6743 for pricing and order placement. 2. DMX - Speaker cabling and DJ cabling by electrical contractor per DMX requirements. Contact Kim McClure at DMX (310) 696-4160 11150 W. Olympic Blvd., #770 Los Angeles, CA 90064 for pricing and order placement. 3. M - Speaker cabling and DJ cabling by electrical contractor per ECI requirements. Contact Bart Reno at ECI (561) 416-5880 3100 NW Boca Raton Blvd., Suite 309 Boca Raton, FL 33431 for pricing and order placement. 4. Rack and associated equipment in rack, speakers, remote volume controls, speaker back boxes and DJ jack cabling. B. This contractor shall install all speakers, remote volume controls, speaker back boxes, associated cabling and DJ jack cabling. C. Speaker locations shown on the drawing are for bidding purposes only. This contractor shall install and wire speakers per speaker vendor provided installation drawings. All cabling shall be run to sound rack location in LAN room. Leave 6 feet tails for final connection to sound equipment by a speaker vendor technician. D. All sound cabling installed above lay -in ceilings shall be supported with bridle rings mounted from building structural members at a minimum of 5 feet on centers. Sound cabling installed above drywall ceilings shall be in conduit. Conduit shall be continuous from speaker -to -speaker. Homerun from last speaker to cash audio rack be in conduit. E. A conduit run shall riot have more than three (3) bends in a run between speakers or between speaker and sound rack. When a run requires more than three (3) bends, a pull box of suitable size shall be place in suitable location to meet the above conditions. F. All final terminations at the sound rack shall be done by H&M's sound system technician. G. No substitutions of Bose, DMX, ECI equipment is permitted. The contractor must purchase equipment directly through Ben Nouryat at BW Solutions, Kim at DMX, or Bart at ECI to ensure compatibility with the system head end provided by H&M. Section 1674® Responsibility Schedule Technology Contractor Electrical Contractor CABLE OUTSIDE DIAMETER mm (in) Complete conduit pathway system including, but not 4.6 (0.18) 5.6 (0.22) limited to conduit, manholes, hand holes, junction 7.4 (0.29) Aft boxes, outlet boxes, plaster rings, ect. 13.5 (0.53) 15.8 (0.62) Fire -rated painted plywood backboards, for In 40 technology use. .622 16 Technology grounding system including, but not 1 0 limited to, ground conductors, copper bus bars and 0 0 all associated hardware required for a complete 0 0 grounding system. 3/4 .824 1" sleeves and firestopping where required 6 Ob Provide pull string in conduit's. (Note 1) 3 2 Bonding of all technology equipment including, but 1 0 not limited to, bonding jumpers and associated 40 1 hardware. 27 8 Provide all CAT5E data cabling and 25 pair phone Aft 6 cabling. 3 2 Provide all data hardware including but not limited 0 0 to data and phone jacks, patch panels, face 1.380 35 plates, technology cabinets, jhooks, cable ties, wire 14 12 management and misc. rack equipment to meet 6 4 specifications. 1 1 Field Quality Control (testing & certification) 1 1/2 1.610 Identification Products 20 18 Notes: 1. E.C. shall provide pull wire when installing conduit. Technical Contractor shall install a separate pull wire for future use when installing cabling. Section 16740: Data Conduit Fill Requirements TRADE SIZE INSIDE DIAMETER CABLE OUTSIDE DIAMETER mm (in) 3.3 (0.13) 4.6 (0.18) 5.6 (0.22) 6.1 (0.24) 7.4 (0.29) 7.9 (0.31) 9.4 (0.34) 13.5 (0.53) 15.8 (0.62) 17.8 (0.70) In mm 1/2 .622 16 1 1 0 .0 0 0 0 0 0 0 3/4 .824 21 6 5 4 3 2 2 1 0 0 0 1 1.049 27 8 8 7 6 3 3 2 1 0 0 1 1/4 1.380 35 16 14 12 10 6 4 3 1 1 1 1 1/2 1.610 41 20 18 16 15 7 6 4 2 1 1 2 2.067 53 30 26 22 20 14 12 7 • 4 3 2 2 1/2 2.469 63 45 40 36 30 17 14 12 6 3 3 3 3.068 78 70 60 50 40 20 20 17 7 6 6 3 1/2 3.548 91 MAX MAX MAX MAX MAX MAX 22 12 7 6 4 4.026 103 MAX MAX MAX MAX MAX MAX 30 14 12 7 TYPICAL 2 -PAIR CAT 3 CABLE TYPICAL 4 -PAIR CAT 3 CABLE TYPICAL 4 -PAIR CAT 5E CABLE TYPICAL 4 -PAIR CAT 6 (WITHOUT DMDER) CABLE TYPICAL 4 -PAIR CAT 6 (WITH DIVIDER) OR 4 -PAIR ScTP CABLE TYPICAL 12 -PAIR CAT 3 UNSHIELDED CABLE TYPICAL 25 -PAIR CAT 3 UNSHIELDED CABLE TYPICAL 50 -PAIR CAT 3 UNSHIELDED CABLE TYPICAL 50 -PAIR CAT 3 SHIELDED ARMM CABLE TYPICAL 100 -PAIR CAT 3 UNSHIELDED CABLE SOURCES: BICSI TDMM, GENERAL CABLE, SUPERIOR ESSEX ®_, ---__ ®® THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax I , „>� � kr'�',', ',ti G r. f p, } %}5" "� rT � r �1 ° G9 ,M1 . ra n�F" �},r� s f 1 Iti � E l� ,,r,'fif ��' t. a t f it {'f�+re? y ,s kt. �,yi r p �}+ R t ,. �. �, ' { J` r 1� M1 .',a C'. '_, t q, rx EN NISCH .'Agd�t s,. ^T4.i.-. is �d li 5 j _.1.;11 ":,, i} ✓9. 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: jp_ P,,,, . I I �11,�(A JEFFERY D. M1TI ERKQ PE: 00517031, _ EB: 0007857 � � ' ' `' \ Expires: 2/28/11 Consultants: FOR: RETAL TANT JQAvc 02.01.01 29110 Inkster Road Suite 200 911248 Southfield, MI 48034 USA il- 248 355 0890 Q 355 0895 Fex Qi a7 wunr.ho.wn JGA .Prj #: 1--209-057 DRAWINGS ISSUED FOR: ❑ programming N schematic des. 02.01.01 ❑ design dev. ❑ bidding # IN permits il- L" Q ® landlord prelim. Qi a7 ® landlord final U) REVISIONS: � LU I I ra-1" o :Z RC t- Q :K 0M 1- ®W.a8 H Q LU W U o 1x C -A U- v " � Z0 J Q Z;;� 0 Y I- O "�` LU a a Civ W I -- DRAWINGS ISSUED FOR: ❑ programming N schematic des. 02.01.01 ❑ design dev. ❑ bidding IN permits 03.12.09 ❑ construction ® landlord prelim. 02.01,01 ® landlord final 02.27.01 REVISIONS: 1Q ADDENDUM #1 03.12.09 Prj. no. 8-209-012 Drawn TBA Checked JDN Approved JDM Do not scale this print. Use figured dimensions only. Drawing title: ELECTRICAL. 5PEC1 FICATION5 Sheet no, HVAC PLAN 1 /8#1= 1 I—O's q GENERAL NOTES: 1. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL EXTENT OF THE WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION AND PROPER INSTALLATION OF ALI MECHANICAL SYSTEMS. THE CONTRACTOR SHALT PROVIDE ALL NECESSARY OFFSETS AND FITTINGS WHICH MAY BE REQUIRED DUE TO SPACE CONSTRAINTS OR OTHER CONDITIONS. 2. THE CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS SUPPORTING STEEL, ETC. FOR THE PROPER INSTALLATION OF ALL MECHANICAL SYSTEMS. 3. THE CONTRACTOR SHALL VERIFY ALL CLEARANCES PRIOR TO FABRICATION OF ANY WORK. 4. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF CEILING GRILLES, REGISTERS AND DIFFUSERS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. 5. DUCTWORK SHALL NOT BE LOCATED OVER THE TOP OF ANY ELECTRICAL PANELS OR EQUIPMENT. 6. THE CONTRACTOR SHALL COORDINATE AND PROVIDE ACCESS DOORS IN HARD CEILINGS FOR ALL EQUIPMENT WHICH REQUIRES ACCESS, SUCH AS: FIRE AND SMOKE DAMPERS, SMOKE DETECTORS, BALANCING DAMPERS, ETC. 7. RETURN AIR TO CENTRAL SYSTEM SHALL BE PROVIDED THRU LIGHT 8. PRIOR TO BID, TENANT TO VERIFY HVAC SYSTEM CONTROLS INTERFACE WITH MALLS CURRENT EMS CRITERIA. MALL MAY USE JOHNSON CONTROLS. CONTACT MALL OPERATIONS FOR REQUIREMENTS. 9, ENSURE TRANSFER AIR OPENINGS THRU DEMISING WALLS FOR RETURN AIR BACK TO MAIN HVAC UNIT ARE BUILT IN COMPLIANCE WITH MALLS MINIMUM 16 SF HVAC SYSTEM REQUIREMENT. VERIFY WITH MALL OPERATIONS. CODED NOTES: FIELD INSTALL DAMPER IN NECK OF DIFFUSERS. ACCESS FOR ADJUSTING BALANCING DAMPER MUST BE THRU FACE OF DIFFUSER. SEE DETAIL ON DRAWING M2.3. O MOUNT TEMPERATURE SENSOR ON EDGE OF COLUMN. COORDINATE FINAL LOCATION WITH H&M REPRESENTATIVE. 'J CONNECT TO EXISTING LANDLORD SUPPLY DUCT. COORDINATE EXACT LOCATION WITH LANDLORD PRIOR TO ANY WORK. Q EXISTING LANDLORD SUPPLY AIR DUCT. O CONNECT TO EXISTING EXHAUST DUCT. COORDINATE EXACT LOCATION WITH LANDLORD PRIOR TO ANY WORK. O EXISTING LANDLORD EXHAUST DUCT. l� PROVIDE NEW 60"x24" RETURN AIR TRANSFER OPENING. O PROVIDE NEW 12"x10" RETURN AIR TRANSFER OPENING ABOVE DOOR IN CEILING SPACE. 0 PROVIDE NEW 24"x24" RETURN AIR TRANSFER OPENING. THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road(330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright 0 2009 KEN NISCH, AIA All rights reserved Certification: AREK A. TOROSIAN PE: 0067682 ❑ programming EB: 0007857 0 schematic des. Expires: 2/28/11 ❑ design dev. Consultants: ❑ bidding RETAIL TAINT ® permits JGA we ❑ construction 29110 Inkster Road 9 Suite 200 A landlord final Southfield, MI 48034 USA 1 248 355 0890 X 248 355 0895 Fax Arl¢®i4. rv®wve�d ' wwi.ha.= JGA Prj #a 1-200--057 DRAWINGS ISSUED FOR: ❑ programming 0 schematic des. a ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction u ® landlord prelim. � A landlord final 02.27.0q REVISIONS: X co LU cv LU La <S LU I o e . )< u-- < :z Z Q 60J Q L DRAWINGS ISSUED FOR: ❑ programming 0 schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction ® landlord prelim. 02.Oq.Oq A landlord final 02.27.0q REVISIONS: 0 ADDENDUM #1 03.12.09 Prj. no. 8-209-012 Drawn TBA Checked AAL" Approved AAT Do not scale this print. Use figured dimensions only. Drawing title: MVAC PLAN Sheet no. 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: AREK A. TOROSIAN PE: 0067682 EB: 0007857 Expires: 2/28/11 Consultants: RETAL DESM CONMTAW JOAw 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax DWAM ®2M �k. N �e www.ha.com JGA Prj #: 1-200-057 DRAWINGS ISSUED FOR: ❑ programming IN schematic des. a ❑ design dev. � ❑ bidding ® permits 03.12.Oq ❑ construction LLI ® landlord prelim. 02.Oq.Oq ® landlord final 02.27.09 REVISIONS: co LU � � o :z Q CT✓ W U O LE < to 0 R of � Cil Ui }-- DRAWINGS ISSUED FOR: ❑ programming IN schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction ® landlord prelim. 02.Oq.Oq ® landlord final 02.27.09 REVISIONS: 0 ADDENDUM #1 03.12.09 Prj. no. 8-209-012 Drawn TBA Checked AAT Approved AAT Do not scale this print. Use figured dimensions only. Drawing title: MECHANICAL LEGEND DETAILS t SCHEDULES Sheet no. M ) s 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 248 355 0895 Fax Copyright @ 2009 KEN NISCH, AIA All rights reserved - J Certification: AREK A. TOROSIAN PE: 0067682 EB: 0007857 Expires: 2/28/11 Consultants: RUQ DESM COWLTANT 9 JOA me 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 1 248 355 0890 248 355 0895 Fox M dOW ,-w,m wwn.ha.com JGA Prj #: 1-209-057 DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction LU ® landlord prelim. 02.0q.0q ® landlord final W REVISIONS: L w a � X a 0 m < LU LU V o J ® z Q 2: O tu O H DRAWINGS ISSUED FOR: ❑ programming M schematic des. 02.Oq.Oq ❑ design dev. ❑ bidding ® permits 03.12.Oq ❑ construction ® landlord prelim. 02.0q.0q ® landlord final 02.27.0q REVISIONS: Prj. no. 8-209-012 Drawn TBA Checked AAT Approved AAT Do not scale this print, Use figured dimensions only. Drawing title: ZONE CHECKSUMS Sheet no. J 1. MECHANICAL SPECIFICATIONS -Section -1501 0 --.-General Requirements A. General 1. Specifications are applicable to all contractors and/or subcontractors for mechanical systems. 2. Check other plans and specifications and fully coordinate with other trades, owner and architect requirements. 3. Conform to all general and special conditions of contract as specified by architect and/or owner. 4. Visit site, check facilities and conditions and make all necessary observations and measurements. Note conditions under which work is to be performed and take all items into consideration in bid. 5. Systems are to be complete and workable in all respects, placed in operation and properly adjusted. 6. Each contractor shall provide for his own clean-up, removal and legal disposal of all rubbish daily. 7. Contractor shall protect his work, his existing and adjacent property against weather. 8. Any work damaged by failure to protection required shall be removed and replace with new material at the contractors expense. 9. Contractor must confirm all utility company requirements and connection points in field, prior to starting work. 10. Arrange for and obtain owner's and insurance representative's permission for any service shutdowns. 11. The contractor shall be solely responsible for construction means, methods, sequences of construction and the safety of workmen. 12. No piping, ductwork, wiring, etc., shall be installed or routed above electrical panels and equipment or through elevator equipment rooms. 13. The mechanical contractor shall coordinate with the electrical contractor and obtain a written approval identifying the electrical characteristics of all mechanical equipment prior to ordering of equipment. No additional payment will be made for lack of contractor coordination of electrical characteristics. 14. During construction the contractor may uncover an existing condition that will have to be modified. Any such work which comes under the jurisdiction of this contractor shall be done by this contractor without extra cost to the owner, as though fully detailed on plans and/or described in the specification. . 15, Work related to the existing building shall be coordinated to minimize interference or interruption of normal building use by owner. Refer to architectural plans for phasing requirements. B. Codes, Permits, Standards and Regulations 1. Conform to all applicable codes (local, state, national codes, NFPA, OSHA, etc.), government regulations, utility company requirements and applicable standards. 2. Obtain permits and pay all fees. Arrange for all required inspections and approvals. C. Related Work Specified Elsewhere 1. Openings and chases, when shown on architectural drawings. 2. Temporary water service, sanitary facilities, fire protection and heating during construction. 3. Poured -in-place concrete. 4. Finished painting. . 5. Electric power wiring. D. Drawings 1. The systems as shown on mechanical drawings are diagrammatic. Confirm all dimensions by field measurement. 2. The exact locations for fixtures, equipment and piping which is not covered by drawings shall be obtained from the architect or his representative in the field and the work shall be laid out accordingly. 3. Drawings and specifications are intended to supplement one another. Any materials or labor called for in one but not the other shall be furnished as if both were mentioned in the specifications and shown on the drawings. E. Base Equipment, Materials and Substitutions 1. All equipment and materials shall be new, free of defects and UL labeled. 2. Base bid manufacturers are included in the specifications or listed in schedules on the drawings. All other manufacturers are considered a substitution. 3. The name or make of any article, device, material, form of construction, fixture, etc., stated in this specification, whether or not the words "or approved equal" are used, shall be known as a "standard". 4. All proposals shall be based on "standards" specified. 5. The equipment schedules on the drawings indicate manufacturers' equipment model numbers that this design has been based on. The use of other manufacturer's equipment that is listed as acceptable alternates that entails general trades, structural, mechanical, electrical, etc., revisions is this contractor's responsibility. Any additional cost of such changes shall be paid by the contractor submitting the acceptable alternates which necessitates changes in installing such submitted alternate equipment, even though such costs may be part of another division of work. 6. Substitutions are subject to the approval of the owner. If a substitution is submitted, it is the contractor's responsibility to evaluate it and certify that the substitution is equivalent in all respects to the base specifications. 7. If substitutions are approved, notify all other contractors, subcontractors, etc., affected by the substitution and fully coordinate with them. Any costs resulting from substitution, whether by this contractor or others, shall be the responsibility of and paid for by the substituting contractor. Approved shop drawings do not absolve this contractor from this responsibility. 8. All equipment shall be installed in full accordance with the manufacturer's data and installation instructions. It is this contactors responsibility to check and conform these requirements prior to starting work. F. Warranty 1. Fully warrant all materials, equipment and workmanship for one (1) year from date of acceptance. 2. Repair or replace without charge to the owner all items found defective during the warranty period. In the case of replacement or repair due to failure within the warranty period, the warranty on that portion of the work shall be extended for a minimum period of one (1) year from the date or such replacement or repair. G. Shop Drawing Submittals 1. Submit shop drawings for mechanical, plumbing and fire protection systems, including but not limited to sheetmetal, plumbing fixtures and equipment with adequate details and scales to clearly show construction. Indicate the operating characteristics for each required item. Clearly identify each item on the submittal as to mark, location and use, using the some identification as provided on the construction documents. 2. Sheetmetal and fire protection drawings shall be fully dimensioned and coordinated based on field verified building clearances and architectural ceiling layouts. Indicate structural, lighting, ductwork and piping at all critical locations. 3. Contractor shall review and indicate his approval of each shop drawing prior to submittal for review. Shop drawings will not be reviewed by the engineer unless the contractor's approval is noted. Do not start work or fabrication until shop drawings have been reviewed by the engineer and returned to the contractor. 4. Submittals will be reviewed only for general compliance with the contract documents and not for dimensions or quantities. The submittal review shall not relieve the contractor of responsibility for the purchase of any item in full compliance with the contract documents or its complete and proper installation. 5. Where submittals vary from the contract requirements, the contractor shall clearly indicate on submittal or accompanying documents the nature and reason for the variations. 6. Each manufacturer or his representative must check the application of his equipment and certify at time of shop drawing submittal that the equipment specified has been properly applied and can be installed, serviced and maintained where indicated on the drawings. Advise engineer in writing with submittal drawings of any potential problems. The manufacturer shall be responsible for any changes that might be necessary because of physical characteristics of equipment that have not been called to the engineers attention at time of submittal. H. Record Drawings 1. Each contractor or subcontractor shall keep one (1) complete set of the contract drawings on the job site on which he shall regularly record any deviations or changes from such contract drawings made during construction. ' 2. The drawings shall record the installed location of all concealed equipment, piping, electric service, sewers, wastes, vents, ducts, conduit, etc., by measure dimensions to each such item from column centerlines or readily identifiable and accessible walls or corners of the building. Plans shall also show invert elevation of sewers and top elevation of all other below -grade lines. 3. Record drawings shall be kept clean and undamaged and shall not be used for any purpose other than recording deviations from working drawings and exact locations of concealed work. 4. After the project is completed, these drawings shall be delivered to the architect in good condition, as a permanent record of the installation as actually constructed. Section 15050 - Basic Materials and Methods A. General 1. Provide all materials, labor, equipment and accessories required .to furnish and install the mechanical items identified in this section. 2. This section includes basic mechanical materials and methods to complement other division 15 sections in this specification and requirements indicated on the mechanical drawings. . Section 15050 (cont.) B. Excavation and Backfill 1. Perform all excavation and backfill required for installation of below -grade piping. 2. Excavate as required to install piping at required depth and pitch. Pipe to be laid on sand bedding to give uniform bearing along length of pipe (sand inside building and interlocking aggregate outside building). 3. Backfill with bedding material to a minimum of twelve (12) inches above top of pipe and compact. Balance of backfill in outdoor grass areas shall be clean earth up to six (6) inches above surrounding grades. Backfill below finished floors shall be sand and outdoors under paving shall be interlocking aggregate. All backfill shall be compacted in maximum twelve (12) inch layers. 4. All other excavations shall be backfilled with clean earth, excluding rubbish and boulders. Backfill shall be thoroughly tamped and puddled. 5. Patch floor to match existing adjacent surfaces. C. Supports and Hangers 1. Hangers and supports are to be provided to properly support, secure and align piping and to meet field conditions and as manufactured by Grinnell or Michigan. 2. Spacing to comply with Ashrae standards and local code requirements. D. Escutcheons 1. Fit all pipe passing through walls, floors or ceilings in finished rooms with steel or brass escutcheons. Where surface is to receive a paint finish make escutcheons prime painted; otherwise make escutcheons nickel or chrome plated. Where piping is insulated, fit escutcheons outside insulation. E. Pipe Identification 1. Identify all pipes and valves in equipment rooms, above accessible ceilings and in accessible shafts. 2. Color code identification bands or marker backgrounds to identify contents of pipe and direction of flow located near each valve and fitting, on both sides of pipe passing through walls and on long runs at not over 20 foot intervals. F. Access Panels 1. Contractor shall be responsible for providing all required access panels necessary for his work. This includes any access panels required for HVAC, plumbing and fire protection. Contractor shall also provide access panels for any existing conditions as required. 2. Refer to architectural drawings and specifications for type of access panel and coordinate locations prior to any work. G. Firestopping 1. All openings through fire rated walls, floors, and/or roofs ' for ductwork, piping, etc. shall be fire sealed with calcium solicate, silicone "RTV" foam, "3M" fire rated sealants, Hilti Firestop Systems or approved equal to maintain the intended fire rating and associated 'UL' ratings. H. Cutting, Patching, and Drilling 1. All cutting and patching of the building construction required for this work shall be by this contractor unless shown on architectural drawings and confirmed as to size and location prior to new construction. Cutting shall be in a neat and workmanlike manner. 2. Neatly saw cut all rectangular openings, set sleeve through opening and finish patch or provide trim flange around opening. 3. Neatly saw cut floors and patch floor to mach existing, including all floor coverings. 4. Contractor shall field verify slab -on -grade or supported floor construction type prior to cutting. Under no circumstances shall this contractor cut a structural floor slab, whether on grade or supported, without prior written approval from the architect. If floor slab indicated to be cut on mechanical plans is found to be structural in nature, do not cut. Contact. architect immediately for further directions. 5. Core drill and sleeve all round openings. 6. Do not cut any structural components without architect's written approval, including, but not limited to roof joists, columns, floor joists, beams, girders, structural floor slabs, etc. 7. Patch and finish to match adjacent areas that have been cut, damaged or modified as a result of the installation of the mechanical systems. Fire stop all penetrations of fire rated construction in a code approved manner. 8. All contractors shall confirm with owner, prior to bid, times available for noise producing work such as cutting and core drilling of floors, walls, etc., as well as times for work which requires access into adjoining tenant spaces. Include any premium time in bid. 9. The mechanical contractor shall coordinate with the general contractor prior to construction. The mechanical contractor shall provide information regarding openings in walls, floors, etc., concrete equipment pads and foundations to the general contractor. If the mechanical contractor fails to comply with this request, or if incorrect information is given, the necessary cutting and patching will be performed by the general contractor at the mechanical contractor's expense. I. Demolition and Removal 1. Disconnect, cap and remove all piping, ductwork and equipment indicated on the drawings or as required for the project. 2. Any equipment designated by owner to be salvaged shall be protected and delivered to the owner on site. 3. Demolition shall be done in a manner so as not to damage adjacent work and not affect the operation of systems to remain in use. Any item to remain that is damaged by the contractor shall be replace and/or repaired at the contractor's expense. 4. All open ended piping and ductwork that is to remain shall be capped and properly secured. 5. All electrical devices, wiring, conduit, etc., related to demolished equipment/systems shall be removed. Wiring shall be disconnected at circuit breakers, removed and breakers marked "spare". 6. Mechanical contractor shall remove and reclaim any refrigerant in existing systems prior to demolition of any equipment according to federal requirements. 7. All asbestos removal will be handled by the owner and is not a part of this work. 8. Examine areas and conditions under which demolition work must be performed. This contractor shall coordinate his work with other trades performing demolition work and/or demolition work performed by the owner. 9. Remove all supports, hangers, etc., related to equipment and material indicated to be demolished. 10. Where temperature controls are indicated for demolition, retain the services of a temperature control contractor to perform such demolition. Section 15100 - InsulaWn A. General 1. Furnish all material, labor and equipment as required to install complete plumbing and HVAC insulation as indicated on mechanical drawings and in these specifications. 2. Install in full accordance with manufacturer's recommendations. B. Plumbing Insulation (As manufactured by Owens-Corning, Knauf or Schuller) 1. Insulate all above grade hot and cold water piping with molded fiberglass having an all service jacket. B.a. Insulation Thickness Schedule: 1.1. Less than (<) 1-1/2" diameter pipe: 3/4" thick. 1.2. 1-1/2" - 8" diameter pipe: 1" thick. 2. Insulate all above -grade, horizontal rain conductors and roof drain sumps with one (1") inch thick molded fiberglass having type ASJ jacket and manufactured by Owens-Corning Fiberglass Company. 3. Include insulation of fittings and valves. Keep vapor barriers intact. Apply to manufacturer's recommendations. 4. Handicapped lavatory insulation - insulate all exposed waste and water supply piping under lavatory with safety covers per ADA requirements as manufactured by Plumberex Specialty Products, McGuire or Truebro. 5. Repair sections of existing piping insulation damaged or damaged during this construction period. Use insulation of some thickness as existing insulation, install new jacket lapping and sealed over existing. C. HVAC Insulation (As manufactured by Owens-Corning, Knauf, Schuller, Armstrong or Rubatex) 1. Insulate all non -lined supply, return and exhaust ducts with 1-1/2" thick foil faced reinforced kraft jacket, fiberglass duct wrap fully secured to duct. Lap and tape seams and secure tightly to the ducts with wire or stick pins. Spiral ductwork in exposed ceiling areas is not to be insulated unless otherwise noted on drawings. 2. All insulation to be applied in full accordance with the manufacturer's recommendation and comply with 25/50 flame and smoke hazard ratings per ASTM E-84, NFPA 255 and UL 723. 3. Provide removable insulation sections to cover parts of equipment which must be opened periodically for maintenance include metal vessel covers, fasteners, flanges, chilled water pumps, frames and accessories. 4. Repair damaged sections of existing mechanical insulation damaged during this construction period. Use insulation of same thickness as existing insulation, install new jacket lapping and seal over existing. 5. Replace damaged insulation which cannot be repaired satisfactorily, including units with vapor barrier damage and moisture saturated units. Section 15200 - Piping and Valves A. General 1. Furnish all material, labor, equipment, and accessories as required to install complete plumbing and HVAC piping systems as indicated on mechanical drawings and in these specifications. 2. Install in full accordance with local code requirements, other specification section requirements and manufacturer's recommendations. Section 15200 (cont.) B. Connections to Equipment Furnished by Others 1. Provide valved water and/or gas connection for equipment furnished by other contractors or owner. 2. Include accessories required by code, drawing or manufacturer's instructions. 3. Fully coordinate with kitchen equipment and laundry suppliers and confirm all rough -in requirements prior to starting work. C. Sanitary 1. Install sanitary, stacks, vents, drains, cleanouts, etc., as indicated on the drawings. 2. Sewers to be pitched a minimum of 1/4" per foot for 3" sizes and under and 1/8" per foot for 4" sizes and larger or to grades indicated on drawings. 3. Changes in direction and branch connections shall be made with approved drainage fittings compatible with the piping system material in which it is installed. 4. All fixtures and sanitary drains shall be vented as indicated on drawings and in accordance with code. 5. Vents are to be extended through roof as indicated on drawings and flashed with 4 Ib. lead with vent flashing top turned down two (2) inches minimum inside pipe. 6. PVC piping shall not be installed unless permitted by code and shall not be installed in return air plenums. 7. Sanitary and vent material shall be as follows: C.a. Below grade storm and sanitary inside building 7.1. Service weight - cast iron pipe ASTM A-74-82 with ASTM C-564-70 neoprene compression joints or no -hub with clamps. 7.2. PVC-DWV plastic ASTM D-1785 with ASTM D-2665 DMV solvent weld socket fittings, C.b. Above grade sanitary and vent material shall be as follows: 7.1. No -hub cast iron pipe CISPI 1-301-78. 7.2. SCH. 40 galvanized steel pipe ASTM A-120-83 with cost iron screwed fittings ANSI B-16.22 1983. C.c. Sanitary sewers 7.1. Up to 15" - PVC plastic ASTM D-3034 SDR 35 with ASTM D-3212 gasket joints. 7.2. 18" and over - reinforced concrete pipe (RCP) ASTM C 76-83 with ASTM C 443-79 rubber gasket joints. D. Domestic Water Piping 1. Install domestic water piping as indicated on drawings. Include all fittings, valves, hangers, and other accessories including water meter and backflow preventer. Extend domestic water piping to all fixtures and equipment required for complete installation. 2. Include unions, or other disconnect means, stops or valves for isolation of fixtures and equipment. Valves to be fully compatible with piping for service intended as manufactured by Nibco, Crane or Milwaukee. Include hose or drain valves at low points where fixtures cannot be used for drainage. 3. Install shock absorbers at each quick closing fixture and where required to prevent water hammer as manufactured by J.R. Smith, Sioux Chief or Zurn. 4. Hangers on insulated pipe to be outside of insulation, sized accordingly and with a sufficient saddle to protect insulation as manufactured by Grinnell or Michigan. 5. Domestic water piping shall be as follows: D.a. Above grade - type "L" hard copper ASTM B 88-832 with wrought copper fittings ASTM B 16.22 1980 and non -lead or antimony solder joints. D.b. Below grade - type "K" soft copper without joints. 6. Flush, vent and sanitize all water piping with chlorine as required per AWWA, local building department and health department codes. E. Fire Protection Piping 1. See Section 15300, Fire Protection Systems. K. Firestopping 1. See Section 15050, Basic Materials and Methods. Section 15300 - Fire Protection Systems A. General 1. Furnish all labor, materials and equipment as required to install a complete fire protection system for project. B. Design Basis 1. Design basis for system shall be per NFPA 13 (latest edition) and local code requirements. 2. System shall be hydraulically calculated as required by code. 3. Pipe sizes indicated on drawing are approximate and shall be verified per 1 the contractor's hydraulic calculations. C. Drawings and Calculations 1. The fire protection system shall be designed, fabricated, and installed by a, Licensed or NICET Fire Protection System Contractor. The engineer ' shall < provide specifications and diagrams to allow letting of a contract for the fire protection portion of the project. The entire system design, material e use and installation shall comply with FM Global engineering guidelines as W minimum. 4 States: AL, DC, FL, GA, KY, MS, NC, OR, SC, T, VA. Attn: Lori Meyer / Simon Tenant Plan Review 103 Regency Manor Drive < Ballwin MO 63011 Phone: (�),g- 052on ac or s al pe orm a f ow es a a n r main an u mi data with calculations. 3. Contractor and designer shall be state certified. D. Piping 1. All piping shall be installed in accordance with NFPA 13, 14 (latest edition) and local code requirements. 2. Fire protection piping shall be as follows: D.a. Inside building - pipe and tubing shall be steel or copper in accordance with NFPA requirements. D.b. Piping shall match existing building standards. D.c. Contractor shall arrange with owner and insurance underwriter prior to shut down of existing systems. D.d. Flush all piping upon completion of project and test per NFPA requirements. D.e. No piping shall be installed at locations subject to freezing. 3. Excavation and backfill - see Section 15050, Basic Materials and Methods. E. Sprinkler Heads 1. Sprinkler heads shall be UL listed, match existing building standards and be manufactured by Central, Star or Viking. 2. Sprinkler heads shall be as follows: E.a. Areas with exposed structure 2.1. Upright - rough brass. E.b. Areas with ceilings 2.2. Recessed - chrome plated with matching two (2) piece, flush escutcheon. 2.3. Concealed - brass finish with off-white ceiling cover plate. 2.4. Sidewall - chrome plated with off-white, two (2) piece, semi -recessed escutcheon. 3. Install concealed heads with flush mounted cover plate in sales area. Cover plate cover to match surrounding ceiling paint colors. See architectural drawings for ceiling color. 4. Install higher temperature sprinkler heads where required by code or application. 5. Submit samples of sprinkler heads to architect prior to fabrication of any piping. F. Valves 1. Install all valves as required by NFPA 13, UL or FM listed and as manufactured by Grinnell, Hammond or Milwaukee. 2. All shut-off valves shall be fitted with tamper switches by fire protection contractor and wired by electrical contractor. Tamper switches shall be as manufactured by Notifier, Potter or Viking. G. Firestopping 1. See Section 15050, Basic Materials and Methods. Section 15400 - Plumbing Fixtures and Equipment A. General 1. Furnish all fixtures and equipment indicated and scheduled on drawings, complete with all accessories, controls, etc., as required. 2. Install in full accordance with manufacturer's recommendations and place in satisfactory operation. B. Water closets (as manufactured by American Standard, Kohler or Crane). 1. WC -1: Floor mount tank type American Standard Cadet no. 2998.012 floor mounted siphon jet with white, open front commercial grade seat with check hinge. Handle shall conform to ADA requirements. C. Urinals (as manufactured by American Standard, Kohler or Crane) 1. R-1: JJandicapped wall hung sil2hon American Standard Allbrook no. 6541.132, elongated rim with Sloan Royal no. 186-1 (1.0 GPF) top spud flush valve with wall mounted carrier. Mount rim 17" above finished floor. Handle shall conform to ADA requirements. D. Lavatories (As manufactured by American Standard, Kohler or Crane) 1. UL -1: Countertop American Standard Aqualyn no. 0476.028 countertop with American Standard Reliant no. 2385.003 single lever faucet, with grid drain and tailpiece. 2. UL -1: -Handicgpped, wall hung. American Standard Lucerne no. 0355.012 with Chicago no. 802-A317CP faucet with E2605-5 aerator, wrist blad grid drain . and insulated offset trap. Rim shall be mounted no more than 34" above the finished floor. 3. -Handicap ed lav, tg� insulation Insulate all exposed waste and water supply piping under lavatory with safety covers per A.D.A. requirements as manufactured by Plumberex Specialty Products, McGuire or Truebro. Section 15400 (cont.) E. Janitor's Sink (as manufactured by Fiat or Mustee) 1. JS -1: Wall mounted Crane no. 7-503 with no. C-5050 faucet with vacuum breaker switch spout, mop hanger, hose with bracket, and stainless steel rim guard no. 8-7083. F. Sinks (as manufactured Just, Elkoy or Moen) 1. SK -1: Single compartment Just no. SWB-2125-A-GR-L, 18 Gauge stainless steel with Chicago no. 2300-8 faucet with E2605-5 aerator and Just no. J-35 crumb cup. G. Electric Water Coolers (as manufactured by Haws, Halsey Taylor or Oasis) 1. C-1: Handicapped i -level Haws model no. HWBFA8L wall hung, surface mounted cooler, 7.7 GPH at 90 degrees F ambient, 1/5 HP, 12OV., 1 phase, R134a refrigerant, color selected by architect. H. Floor Drains (as manufactured by J.R. Smith, Josam, Mifab or Zurn) 1. FD -1: (general service) J.R. Smith Series 2005 (6" diameter for poured floors, 6" square for floors with a straight line pattern), flat strainer with nickel bronze finish, flashing clamp and 1/2" trap primer connection. I. Cleanouts (as manufactured by J.R. Smith, Josam, Mifab or Zurn) 1. CO -1: Floor mounted J.R. Smith Series 4020 (poured floors or series 4040 finished floor with a straight line pattern) with satin finish bronze top. J. Trap Primer Valves (as manufactured by Precision Plumbing Products, Sioux Chief or Zurn) 1.PT V-1: Precision Plumbing Products Oregon No. 1. Provide distribution unit for multiple drain connections. Section 15500 - Hegt Generation Equipment A. General 1. Furnish all material, labor, equipment, and accessories as required to install equipment as indicated on mechanical drawings. 2. Install in full accordance with local code requirements, other specification section requirements, and manufacturer recommendations. B. See equipment schedules on mechanical drawings. Section 15600 - Refrigeration Equipment A. General 1. Furnish all material, labor, equipment, and accessories as required to install equipment as indicated on mechanical drawings. 2. Install in full accordance with local code requirements, other specification section requirements, and manufacturer recommendations. B. See equipment schedules on mechanical drawings. Section 15700 - HVAC Systems and Equipment A. General 1. Furnish all equipment, material, labor, tools, etc., for the complete HVAC system. Install complete and place in operation. 2. Contractors bidding this project shall visit this site and familiarize themselves with all conditions affecting their work. Submission of a bid on this project shall be construed as having such knowledge. 3. Verify exact conditions in field and coordinate with these drawings and other trades before beginning new work. 4. Determine exact locations for all new and relocated equipment, piping, conduits and ductwork in field. 5. Coordinate work of this contract with other trades. Conflicts shall immediately be brought to the attention of the architect. Architect's resolution to conflicts shall be final. 6. Any discrepancies between what is shown on drawings or specified and the actual conditions in the field shall immediately be brought to the attention of the architect before proceeding. 7. Building and surfaces damaged during installation shall be repaired, replaced, and/or restored to original condition after completion of work and before acceptance by owner. B. Equipment 1. Mechanical contractor to furnish all HVAC equipment indicated and/or scheduled on the drawings complete with bases, isolators, supports and other required accessories. 2. Install complete and place in proper operation per manufacturer's recommendations, lubricate and adjust as required. Furnish and install clean set of filters prior to balancing. 3. Equipment to be make and model as scheduled unless alternate equipment of equivalent quality and performance is submitted as a substitution prior to bidding. All substitution are subject to acceptance without qualification by owner, engineer and architect. 4. Submit service report to any major component failures or malfunctions. Report shall include cost to service all malfunctioning or damaged items listed. Cost shall include parts and labor. Equipment shall be placed in full operation with controls calibrated upon completion of project. C. See equipment schedules on mechanical drawings. Section 15800 -Air Distribution Systems A. General 1. Furnish all materials, labor, equipment and accessories required to install complete air distribution systems. 2. Contractors bidding this project shall visit this site and familiarize themselves with all condition affecting their work. Submission of a bid on this project shall be construed as having such knowledge. 3. Verify exact conditions in field and coordinate with these drawings and other trades before beginning new work. 4. Determine exact locations for all new and relocated ductwork and accessories field. 5. Coordinate work of this contract with other trades. 6. Any discrepancies between what is shown on drawings or specified and the actual conditions in the field shall immediately be brought to the attention of the architect before proceeding. 7. Building and surfaces damaged during installation shall be repaired, replaced, and/or restored to original condition after completion of work and before acceptance by owner. B. Ductwork 1. Fabricate and erect all ductwork to Ashroe and Smacna standards from no. 1 galvanized steel. Comply with NFPA 90A requirements. 2. Ductwork shall be Smacna low pressure construction 2" static pressure rating with seal Class B seams and joints. 3. All exposed ductwork shall be spiral type ductwork. 4. Ductwork upstream of VAV and FPVAV terminals shall be Smacna medium pressure construction 4" static pressure rating with Class A seams and joints sealed with EC -800 compound or similar. 5. Include all acoustic, airfoil shaped perforated aluminum turning vanes, manual dampers, flexible connectors, grilles and diffusers, acoustic lining, and other sheet metal accessories for the project. 6. All branch connection fittings in rectangular ductwork shall be 45 degree transition type, conical fittings or spin -in fittings with integral air scoops. Butt fittings are not acceptable. C. Duct Liner 1. Acoustic line all rectangular ducts within first 10 ft. downstream of all FVAV boxes with one (1) inch thick non -flaking, coated medium density liner, apply to manufacturer's recommendations. 2. Duct dimensions indicated on drawings are clear inside dimensions (free area). 3. All rectangular ductwork 10 ft. downstream of FPVAV boxes shall be lined with 1" coated medium density liner. Apply to manufacturer's recommendations. 4. Duct liner shall comply with NFPA 90A and 908 (latest edition) requirements. D. Duct Accessories 1. Flexible ductwork (as manufactured by Clevaflex, Flexmaster or Wiremold). D.a. Flexible ducts shall be independently supported from the structure and connected with plastic draw bands and tightened. Flexible ducts shall be limited to 48" maximum straight length. Flexible ducts shall be constructed of 1 1/2" insulation with vinyl vapor barrier jacket and rated at 10" W.C. for sizes though 12", UL listed, and meet 25/50 flame and smoke test. Flexible ducts are not permitted in rooms without ceiling. 2. Dampers (as manufactured by Ruskin, Nailor or Safe -Air) D.o. Fabricate in accordance with Smacna Standards. Provide end bearings and locking, indicating quadrant regulators. Blade to be single thickness with continuous hinge or rod. 3. Control Dampers (as manufactured by Ruskin, Nailor or Safe -Air) D.a. Fabricate blade of double thickness sheet metal, opposed blade type with self -aligning rod and end bearing suitable for use with an actuator. 4. Fire Dampers (as manufactured by Ruskin, Nailor or Safe -Air) D.a. Fabricate in accordance with NFPA 90A and UL555. Dampers shall be suitable for us in the vertical or horizontal position as indicated on the drawings, be type 'B' with blades out of airstream, and be rated for 1-1/2 hours minimum (unless noted otherwise). D.b. Provide duct mounted access doors at all fire damper locations. 5. Access Doors (as manufactured by Ruskin, Nailor or Safe -Air) D.a. Fabricate in accordance with Smacna standards. Doors to be fabricated of galvanized steel with sealing gasket and quick locking device. D, b. For insulated ductwork, doors shall have minimum one (1) inch insulation with sheet metal cover. Section 15800 (cont.) E. Firestopping 1. See Section 15050 Basic Materials and Methods. Section 15900 - HVAC Instrumentation and Controls A. General 1. Furnish and install complete temperature control for all HVAC systems. 2. Provide new control devices including thermostats, humidistats, damper operators, motors, temperature sensors, staging relays and other related devices for a complete operational system per the operating sequence and industry standards. 3. Mount all controls furnished as accessories to equipment and provide all control wiring required for proper operation. All wiring shall be in conduit per N.E.C. and local code requirements. 4. Mechanical contractor shall install all duct mounted smoke detectors. Electrical contractor shall furnish and wire photo -electric duct smoke detectors at each unit to shut down fan upon activation. Detector shall be A located in the return air duct upstream of the unit connection. Detector 5." FVAV dnd" VAV 'bokes shalT be con'trolleci by digTRal space sensors-AI spa e sensors shall be tied into the landlords Johnson Controls Metasys building management system. Sensor &VAV/EVAN box installation and wiring by TC contractor, final tie-in to LL BMS system by LL BM5 contractor B. Sequence of Operation:. 1. Toilet Room Exhaust Fan (EF -1) B.a. Interlock fan with light switch to operate when lights are turned on (interlock wiring) by electrical contractor, 2. Toilet Room Exhaust Fan (EF -2) B.a. Fan shall be interlocked with RTU -1 and run continuously during occupied hours. 3. Exhaust Fan (EF -3) B.a. Upon a call for cooling from the space mounted thermostat, the exhaust fan shall start and the outside air damper shall open. Onc,,.,, the thermostat has been satisfied, the fan shall stop and the outside air damper shall close. 4. Variable Air Volume Box (VAV) with reheat coil B.a. Space mounted thermostat shall modulate the damper operator on the VAV box to maintain space setpoint temperature. B. b. The thermostat shall also control the (three-way) (two-way) valve on the hot water coil to maintain space temperature. The damper operator shall be furnished by the temperature control contractor. 5. Fan Powered VAV Unit (FPVAV) B.a. Space mounted thermostat shall control the FPVAV box and electric heating coil. B. b. During unoccupied mode the fan will cycle. Upon a call for heating, the fan shall start and the electric heating coil shall energize. Cooling shall be locked out. B.c. During occupied mode, the space mounted thermostat will cycle heating or cooling to maintain space setpoint temperature. Section 15950 -jesting,.,Adjusting and Balancing„ A. General 1. After installation, check all equipment and perform start up in accordance with the manufacturer's instructions. 2. All piping shall be tested and free of leaks as required by the local authority having jurisdiction. 3. Work that is scheduled to be concealed or insulated shall remain uncovered until required tests have been completed. If the construction schedule requires, arrange for tests on sections of the system at a time. 4. Balance all systems, calibrate controls, check for proper operation and sequence under all conditions and make all necessary adjustments. 5. Instruct owner in operation of systems and submit operating and maintenance manual for all equipment and systems. 6. Submit air and balance report from independent AABC or NEBB certified subcontractor for all air systems per AABC or NEBB standards. B. Balancing, Start Up and Instructions 1. After equipment is placed in operation, systems shall be balanced to within 10% of design flow with report submitted to owner. Balancing shall be performed by an independent AABC or NEBB certified contractor. 2. Test, adjust and balance cooling systems during summer season and heating systems during winter season. Balance systems when the outside air conditions are within 5 degrees F wet bulb temperature of the maximum summer design condition and within 10 degrees F dry bulb temperature of the minimum winter design condition. 3. Start up and place all systems in operation and tag all switches and controls with permanent labels. 4. Instruct owner on proper operation and preventative maintenance of system. ®'---,-_ ®® THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659-6688 Ph. Richfield, Ohio 44286 (330) 659-6675 Fax 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248355 0890 248 355 0895 Fax Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: AREK A. TOROSIAN PE: 0067682 EB: 0007857 Expires: 2/28/11 Consultants: FOR: WAL IDESM COMILTANT J13A qac 02.Oq.Oq 29110 Inkster Road U_ Suite 200 11;: Southfield, MI 48034 USA 03.12.Oq 248 355 0890 248 355 0895 Fax Twww.ha.corn ® landlord final JGA Prj #: 1-209--057 DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.Oq.Oq ❑ design deo. U_ ❑ bidding # ® permits 03.12.Oq L" ® landlord prelim. 6 u) ® landlord final a REVISIONS: :Z0) � LU %-9 0 I W o " pC " Q M }- QC H - u` LU U u- ur H 0 v 0 � Q -Q 0 J 41 ;:;� i� t- W a 11.E o o < 11-ina W �-- DRAWINGS ISSUED FOR: ❑ programming ® schematic des. 02.Oq.Oq ❑ design deo. ❑ bidding ® permits 03.12.Oq ❑ construction ® landlord prelim. 02.0q.0q ® landlord final 02.27.Oq REVISIONS: Q ADDENDUM #1 03.12.09 Prj. no. 8-209-012 Drawn TBA Checked AAT Approved AAT Do not scale this print. Use figured dimensions only. Drawing title: MECHANICAL SPECIFICATIONS Sheet no. 14 0 k . 4 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 I 248 355 0895 Fax I Copyright © 2009 KEN NISCH, AIA All rights reserved Certification: I cli, I AREK A. TOROSIAN PE: 0067682 E13:0007857 Expires: 2/28/11 Consultants: 'fAL SMT JOA w 29110 Inkster Road Suite 200 Southfield, MI 48034 USA 248 355 0890 111 248 355 0895 Fax www.hO.COM JGA Prj #: 1-209-057 i, DRAWINGS ISSUED FOR: ❑ programming 19 schematic des. O ❑ design dev. ❑ bidding ® permits 03.12,Oq Lu < ® landlord prelim. c� X U) REVISIONS: co L ' LU O LU :Wr-0 j Q O Lu LU V O LU c o � 41 LL- _! < O DRAWINGS ISSUED FOR: ❑ programming 19 schematic des. 02.0q.0q ❑ design dev. ❑ bidding ® permits 03.12,Oq ❑ construction ® landlord prelim. 02.Oq,Oq IN landlord final 02.27.0q REVISIONS: 1A ADDENDUN #1 03.12.Oq Prj. no. B-209-012 Drawn TBA Checked AAT Approved AAT Do not scale this print. Use figured dimensions only. Drawing title: PARTIAL PLUMBING PLAN Sheet no. s