Loading...
HomeMy WebLinkAbout210 Tech Dr - BC05-001026 - UPGRADE FIRE ALARM MONITORING SYSTEMt. ' CITY OF SANFORD PERMIT APPLICATION Permit # : — t C) D ( Date: 17 DEC 2004 Job Address: 210 TECH DRIVE Description of Work: UPGRADE EXISTING FIRE ALARM MONITORING SYSTEM Historic District: Zoning: Value of Work: $ 9,856.00 Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm X Pool _ Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole _ Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # ofFixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair — Residential or Commercial _ Occupancy Type: Residential Commercial X Industrial Total Square Footage: 24, 500 Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required for other than X) Parcel #: Owners Name & Address Attach Proof of Ownership & Legal Description) Y.0:0)NDJMWIWfAF/t! CLaI/ FFAr* i•L'!C it Beading Company: Address: Mortgage Lender: " Address: r+ DEG 2 1 Architect/Engineer: + Phone: 4 Address: ns tar+ Win A. P i 1 t< Application is hereby made to obtain a permit to do the work ind otallati issuance ofa permit and that all work will be performed to meet sondards permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, AIR CONDITIONERS, etc. , work or installation has commenced prior to the n in this jurisdiction. I understand that a separate BOILERS,. HEATERS, TANKS, and OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addi on the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and a may be ad itional permits required from other governmental entities such water management drSS71, state agencies, or federal agencies. Accep a rmit is y ific Non th I will otify net of the property of the requi is o Florida Lien Law3 i ignature of Awrter/Agent Date'Signature ofContractor/Agent Date THOMAS VANDER RICHARD D BYRNE Print Otwgpr/Agent'sName / / Pnntractor/Agent's Name Signature of Notaryl hate gnature ofNotary:S46e of Florida Date Owner/Agent is —VlPersonally Known to Me or Contractor/Agent is Personally Known to Me or Produced ID // _ Produced ID APPLICATION APPROVED BY: Bldg: (P 05 Zoning: Utilities: FIX: initial Date) (Initial & Date) (Initial & Date) (Initial Special Conditions: I NON No1al ^+n c - sta1. or Plolido CDD232955 Wded By NpkMI Notary Assn. k (- C-) A 1 CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES PHONE # 407-302-1091 * FAX #: 407-330-5677 DATE: PERMIT #: 0 IV\ R -BUSINESS NAM / PROJECT: C ('?'d, ADDRESS: PHONE NO.: FAX NO.: CONST. INSP. [ ] C / O INSP.:[ ] REINSPECTION [ 1 PLANS REVIEW [ j F. A.qj F.S. [ ] HOOD [ ] PAINT BOOTH [ 1 BURN PERMIT [ J TEN ERMIT TANK PERM [ J OTHER [ ] TOTAL FEES: $ (PER UNIT SEE BELOW) Address / Bldg. # / Unit # Sguare Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. 1 certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the Ci of Sanford, Florida. Sanford Fire Prevention on Applicant's Signature Iss EQUALIZER SYSTEMS & SERVICES, INC. EF0000047 MBF/GRAND INC. 210 TECH DRIVE SANFORD, FL 32771 FIRE ALARM SYSTEM — NFPA 72 UPGRADE EXISTING) ESS PROJECT #24013 NFPA 72A (BATTERY CALCULATIONS) TOTAL TOTAL QTY EQUIPMENT STANDBY ALARM 1) SK5207 FACP .120A .700A 1) SK5205 DIGITAL COMM .010A .100A 2) SK5230 REMOTE ANNUNCIATOR .060A .120A 1 ) SMOKE DETECTOR (FACP ) .001A .100A TOTAL .191A 1.020A 191A X 60 HRS ) + (1.020A X 5 MIN) = TOTAL AH 11.46A) ' + (.085A) = 11.545 AH SAFETY FACTOR X 1.20 = 13.850 AH MINIMUM BATTERY SUPPLIED = 14.000 AH TOTAL ALARM NOTIFICATION = 1.020 AVAILABLE NOTIFICATION SUPPLY = 5.00A 407) 331-5225 280 South Ronald Reagan Boulevard • Suite #112 • Longwood, Florida 32750 (FAX) 331-3806 Iss EQUALIZER SYSTEMS & SERVICES, INC. EF0000047 MBF/GRAND INC. 210 TECH DRIVE SANFORD, FL 32771 FIRE ALARM SYSTEM — NFPA 72 UPGRADE EXISTING) ESS PROJECT #24013 NFPA 72A (BATTERY CALCULATIONS) TOTAL TOTAL QTY EQUIPMENT STANDBY ALARM 1) SK5495 DIST POWER MODULE .O75A .175A 24) AUDIO/VISUAL DEVICES .000A 3.84OA 6) VISUAL/ONLY DEVICES .000A .96OA TOTAL .O75A 4.975A O75A X 60 HRS) + (4.975A X 5 MIN) = TOTAL AH 4.50A) + (.42A) = 4.920 AH SAFETY FACTOR X 1.20 = 5.900 AH MINIMUM BATTERY SUPPLIED = 8.000 AH TOTAL ALARM NOTIFICATION — 4.975 AVAILABLE NOTIFICATION SUPPLY = 6.00A 407) 331-5225 280 South Ronald Reagan Boulevard • Suite #112 • Longwood, Florida 32750 (FAX) 331-3806 f COMMERCIAL FIRE ALARM CONTROL PANEL Mode15207 Fire Control Panel with Digital Communicator and Accu-Zone Your All -In -One Answer For Fire Protection. lhallodekoaf' an all -in -one fuseless local fire evacuation control panel and digital communicator designed for applications requiring manual fire alarm, automatic fire alarm and water flow for sprinkler supervision. The basic unit offers fire alarm for one to eight zones, expandable to 16 with the optional 5210 expansion module. It is compatible with both two - and four -wire smoke detectors. Compact, easy to install and service, it delivers the features you'd expect to find in fire systems costing much more. Features Eight zones, 6 Class B (Style A) and 2 Class A (Style D). 8 Expander Zones are Class B (Style A). Zones are Interchangeable using the Model 7181. Zone Converter. UL, FM, MEA (BSA), CSFM Listed and Approved. Event Memory. Fuseless design reduces service time. 24 VDC power supply. Compatible with 2- and 4-wire smoke detectors as well as water flow and sounding devices. ANSI cadence pattern output. Four programmable (Style Y) supervised signal circuits, Including steady, pulse and temporal. Specifications Electrical: Operating Voltage: 24 VDC Primary AC: 120 VRMS ® 60 Hz, 2A Accessory Current: 5A ® 24 VDC Mechanical: Programmable smoke verification, pre - alarm delay, and cross -zoning can minimize false alarms. Four general purpose relays (Form C 24 volts at 2.5 amps resistive). Built-in approved digital communicator with UL required priority reporting. Flexible programming capabilities including up/downloading and use of remote annunciator. Aocu-Zone® diagnostics facilitate local and remote troubleshooting. Walk Test. General Purpose Relays: 4 Form C: 24 Volts ® 2.5 amps resistive Indication Lights: AC/DC Power: Dimensions: 16' W x 26.4' H x 4" D Operating Temperature 40.6cm W x 67cm H x 32OF to 1209F (0°C to 490C) 10.2cm D) Weight: 25 lbs. (11.4 kg.) Indicator Lights: Color: Red AC/DC (Green): ON=System running on AC Telephone Requirements: Flashing=On DC power FCC Registration No.: AC6USA-65475-AL-E ALARM (Red): ON=Supervisory Alarm Type of Jack: RJ31 X (2 required) Flashing=Fire Alarm 154"? TROUBLE (Yellow): ON=Trouble Condition OFF=No Troubles SILENCE (Yellow): ON=lf trouble or alarm has been silenced MEMORY (Yellow): ON=lf an Alarm is reset SET MODE (Yellow):ON=lf panel is in test or REPORT program mode. Flashing=Panel reporting SILENT KNIGHT Model 5207 Fire Control Panel With Digital Communicator and Accu-Zone® Optional Accessories This 4-wire, 16-zone remote annunciator English -language is easy to operate. Its fourteen function keys can perform the same operations as the main system annunciator, including silencing, resetting, and the displaying of alarms, troubles and alarm memory. The Model 5230 can be used to program all programmable options and with the use of access codes prevent unwanted tampering. Model 4100 stall Display Module The 4180 provides 16 outputs to give alarm and trouble conditions by zone. Two snits can be connected to annunciate all 16 zones on a 5207 control. The 16 outputs can be used to drive LEDs or a graphic annunciator. Non -supervised) Model 7181 Fin Zone comoft Converts Class B zones to Class A and vice versa. Zone bipue" Model S220 Direct conned ModelsThe5210addseightadditionalClassB Style A) zones to the 5207, enabling use Used for city box and polarity reversing of both 2- and 4-wire smoke detectors. direct wire applications. Model SS30 Doweloadhq Mn ', m SIA format modem for remote programming the 5207. SS41 Dowelooding Soften For remote programming the 5207 with an IBM PC or compatible computer. Requires a 5530 modem. The modem and software can be purchased as a package, order. pa;! 5561. 5260 Pihdw letedeas Allows connection of a standard computer printer to provide a printed record of the 5207 system activity. (Printer not supplied.) Engineering Specifications The contractor shall provide a complete electrically supervised fire alarm and communications system. The system shall contain a fire alarm control/communicator and panel to supervise and operate heat and product of combustion detection devices, alarm signal devices, visual annunciator and an Integral digital communicator to transmit fire alarm and supervisory signals to a central station. The control/communicator shall be UL listed or FM approved for use under NFPA 72 for Central Station, Local Protective, Remote Signaling, and Auxiliary Signaling standards. It shall provide power and control for eight supervised detection zones, four supervised alarm signal circuits and a dual digital communicator. The oontrol/communicator shall be expandable to sixteen supervised detection zones and shall be able to communicate to a central station in SIA, SK FSK1, SK 4/2 or Radionics BFSK formats. The control/communicator shall be model 5207. There shall be two Class A and six Class B detection zones. They shall accommodate heat detectors, products of combustion detectors, manual pull stations, sprinkler flow switches and gate valve supervisory switches intermixed as permitted by NFPA 72. Products of combustion may either be 2- or 4-wire and shall be cross listed by UL for use on the system. The detection zones shall be programmed to (1) be cross zoned so that two individual zones must sense products of combustion, (2) automatically reset a detector to verify that products of combustion exist, (3) see a single detector in alarm before the alarm is sounded and a signal Is transmitted to the central station. There shall be four 1 amp supervised (Style Y) alarm signal circuits. They shall cause the notification appliances to ring steady/pulsing/temporal throughout the premises until reset or silenced. The control shall be equipped with four auxiliary relays that shall be programmed to operate on (1) pre -alarm, (2) tamper alarm, (3) special alarm, (4) fire alarm, 5) trouble, (6) no-ollence, (7) alarm by specific zone (1-16). The relays shall remain energized until the panel Is silenced, reset or the trouble condition Is cleared, unless 'no -silence' Is selected. The control/communicator shall have an integral annunciator to Indicate sequentially zones in trouble and system functions. LEDs shall augment the display to make clear to an operator the system status. An Integral touchpad shall be provided to operate and interrogate the system. Vital operations such as alarm silencing or reset shall be simple and obvious to an operator. Authorization pass codes may or may not be used. The control/communicator shall have the capability to supervise two telephone lines, seize the phone line, and send the alarm signal on one or both lines without the addition of any more equipment. It shall sound a local trouble signal if the telephone service is interrupted for longer than 45 seconds and it shall transmit a signal Indicating the loss of phone line service to the central station over the remaining phone line. A signal shall also be transmitted indicating the restoral of phone service. The control/communicator shall be able to report the loss of either phone line without regard to which phone line failed initially. If both lines fail, a local signal shall sound. The control/communicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program feature within the panel. The alarm signals transmitted to the central station shall indicate which of the eight zones is in alarm and which zones are in trouble, depending on which format Is used. Restoral from alarm or trouble signals shall also be transmitted by zone. The control/communicator shall be capable of communicating to Silent Knight, Radionics or Ademco central station receivers. SILENT IQ TIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-44646444 or in Minnesota 612-493-6435 FORM» 350376, Rev. 11/97 FAX: 612-493-6475 World Wide Web: http:/Avww.silentknight.com Copyright 0 1997 Silent Knight W Firepower 5495 Distributed Power Module an emergency, need maximum power. power 5495 Distributed Power Module by Silent Knight is the most - and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power — what you need to drive power-hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need Firepower 5495. Call Silent Knight today for more information at 1-800-446-6444. Firepower 5495 Distributed Power Module The firepower 5495 is a notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5207 Fire Control Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). With 6 amps of notification power, Firepower 5495 drives the additional sounders and brighter strobes required. Meeting ADA requirements is easily accomplished in a retrofit or new installation. Features UL Listed for 6 amps of notification power. Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems. Dip switches allow for easy reconfiguration. 24 VDC filtered output voltage. Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B. Additional continuous auxiliary output. 3 amps per output circuit. 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator. Independent trouble relay. AC loss delay option shuts off power to non -essential high -current accessories like magnetic door holders. Stand alone operation. Lightweight design adds to ease of installation and reduces shipping costs. Operates with most polarized, UL Listed notification devices. UL 864 & 1481 listed. CSFM approved Connection to Local Fire Control Firepower 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the Firepower 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7W end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one Firepower 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Firepower 5495 Distributed Power Module 3 SILENT K0NIGHT Firepower 5495 Distributed Power Module Supervision Current: Input Firepower 5495 supervises a Standby 75 mA voltage range: 9 - 32 VDC variety of functions including: Alarm 175 mA Battery charging Low AC power. Auxiliary capacity: 7.0 AH Low battery condition. power circuit: 1 Ambient Temp.: 32° to 120° F Earth ground fault. Notification 00 to 490 C Auxiliary output power limit circuits: 4 Mechanical condition. Output Dimensions: 12.25" W x 16" H x EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output. 1 Class A & 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights Firepower 5495 creates a trouble Amps per AC power on: Greenconditiononthehostcontrolsignal circuits to which it is connected. output circuit: p 3.0 6.0 amps totalp ) Battery trouble: Yellow Firepower 5495 still maintains the Notification Ground fault: Yellow ability to be activated by the host circuit output: 20.4 to 27.3 VDC Aux Trouble: Yellow control. In addition, the 5495 @ 3.0 amps each, provides a Form C trouble relay 4.7 kQ EOL Output output as an alternative to using resistor required troubles (1-4): Yellow the notification circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 No. of inputs 2 NFPA: 72 AC Input: 120 VAC at 2 amps Input CSFM Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 put Distributed Signal 2 Signal Circuit Output Signal 2 input Power Signal 3Module5495 Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control Alternative to notification circuit trouble.) SILENT KNIGHT 7550 Meridian Circle, Maple Grove, MN 55369-4927 MADE IN AMERICA 800-446-6444 or in Minnesota 612-493-6435 FORM# 350395, Rev. 2/99 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com Copyright 01999 Silent Knight E S L P R O D U C T I N FORMATION B U L L E T I N 103 SERIES Manual Fire Alarm Stations L LOM Model 103-20 manual fire alarm is a manually operated non -coded device for initiating fire alarm signals. The pull handle latches until the station is reset by opening the Single action station cover. Operation of the pull handle closes a single -pole or Dual action double -pole switch. Two wire barrier terminals are provided, each accommodating two conductors, #14 Terminal connections AWG or smaller. Opening the cover also closes the alarm Die cast aluminum alloy initiating switch to allow testing. Both 103-22 (Hex key reset) and 103-42 (cat 30 key Semi -flush or surface mounting reset) are dual action stations that are provided with a Weather/explosion proof cover which must be lifted to expose the pull handle. A break -glass rod is included with each station for models available optional use. UL Listed Model 103-24 pre -signal fire alarm station is identical to Model 103-20 except for the addition of a key -operated switch accessible only after the pull handle is operated. The key is removable in either switch position. When the key slot is vertical, the switch is closed. When the slot is horizontal, the switch is open. An additional two-line terminal strip is provided for the connection of wiring during installation. For outdoor or harsh environment applications, use either the 103-60 (water/weatherproof single action station) or 103-80 (weather/explosion proof single action station). continued Sentrol 103 Series Manual Fire Alarm Stations Application The 103 Series manual fire alarm stations are intended for use as fire alarm initiating devices, with any fire alarm initiating circuit to be operated by a contact closure rated not more than 10 amperes, 125 VAC. Installation The 103 Series manual fire alarm stations mount to standard single -gang electrical boxes or to a plaster ring. The maximum depth of the equipment is 1 1/4". Model 103-25 surface mounting box is available. The . box is 5" high x 3 1/4" wide x 2 3/4" deep. All stations should be installed in compliance with the applicable NFPA standards, local building codes, and plans and specifications. Ordering Information Product Data Contact Ratings..................................10A 0 125 VAC Mounting ...............Flush Standard Outlet Box with one device cover at least 1 3/4" deep Surface Model 103-25 ............................... Surface Box 5"H x 3 1 /4"W x 2 3/4"D Material ....... Die cast aluminum alloy —enameled finish Color .................................... Red housing —white handle Operation ............. General alarm —single or dual action Pre -Signal —Key Operated Removable in either position Shipping Weight Station..............................................................20 oz. SurfaceBox......................................................14 oz. Model gescriptio Single action manual fire alarm station, hex key reset, non -coded SPST. 1 103-21 Same as above except DPST 103-22 (s)' Dual action manual fire alarm station, hex key reset, non -coded SPST. s)' with NY stripe 103-23 Same as above except DPST 103-24 Pre -signal dual action fire alarm station, hex key reset, with key -operated switch accessible after pull handle is operated. 103-25 Surface mounting box. 103-26 Replacement break -glass rod. 103-31 Single action (SPST) with key reset 103-32 Single Action (DPST) with key reset 103-35 Back box (RED) 103-42 Dual action manual fire alarm station, cat 30 key reset, non -coded SPST. 103-60 Water/weatherproof, single action (SPST) with key reset 103-80 Explosion proof, single action (DPST) with hex reset SENTROL, INC Sentrol reserves the right to change 12345 SW Leveton Dr., Tualatin, OR 97062 without notice. without notice. Tel.:503.692.4052 Fax:503.691.7566 httpJ/www.sentrol.com i996 Sentrol, Inc. SL U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 A PRODUCT OF S E N T R O L. INC FaxBack: 1.800.483.2495 E-2277-FLG10K-1296 Printed on recycled paper www. GE-Interlogix. corn Overview The ESL 500 Series self -diagnostic, 2 and 4-wire photoelectric smoke detectors are the industry's first conventional direct -wire smoke detectors with analog features such as drift compensation mull -criteria detection and remote maintenance/trouble reporting CleanMe) on the 2-wire. The 500 Series continually monitor their own sensitivity and operational status, andprovide a visual andremote trouble condition ifthey drift out of the sensitivity range or rail internal diagnostics. This meets NFPA 72field sensitivity testing requirements withoutthe need for externalmeters. The 521 has a unique feature enabling It to send a signal CleanMe) to the ESL 505 module (sold separately) when it has drilled outside of itsLit Listed sensitivity range or has failed its internal diagnostic test. The 505 is an interface module that will signal M panels via relays when the 2-wire 500are dirty. Several control panels have the CleanMe software built in, eliminating the need for the 505 module. When CleanMe is not desired, simply leave the switch on the 2-wire series off and itwill work as a normal 2-wire detector. CleanMe allows the installer time to schedule a service call and avoid a false alarm. Time between cleaning detectors is dramatically increased because of the 5001s built-in drift compensation. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing dust life. And when the 500 Series has told YOU thatcleaning is necessary, it's literallya snap with ESL's patented field replaceable optical chamber. The multi - criteria model 50OXT photoelectric smokedetector/fixed rate of rise heatdetector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photoelectric smokedetector As soon as the heat sensor detects a rapid rise intemperature the sampling rate increases to detect smoke faster, ESL 500 Series Low Profile, Self -Diagnostic Two & four -Wire, Photoelectric Smoke Detector Standard Features CleanMe - remote maintenance reporting reduces false alarms on 2-wire module Smart dual fixed/rate of rise heatswork with photo chamber to catch fires faster Built-in drift compensation reduces false alarms Field replaceable optical chamber makes servicing a snap Small, low pile design blends in with any environment Ift wleanMe 400 CON ATIM Architectural and Engineering Specifications The ESL SM Series photoelectric smoke detector is a low-pronle, selfdiagnostic, two -Wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 Held sensitivity requirements without theneed for external meters. Built in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. Thisrate doubles uv w a signal exceeding the alai threshold value Is sensed. Two additional successive signals above the threshold level will Initiate an alann. See Installation Instructions for Information about co rect Installation and maintenance. The proprietary optical sensing chamber is Held replaceable, alloWing quick and easy cleaning and maintenance. Dimensions Sim L I27mm Ordering Information Description 918 521BXT 521B-10PK 521BXT-10PK 521CRXT 541C 541CXI 541C-10PK 541CXT-10PK Accessories for 521 505 401 SM-200 211 hL Specifications Product Data 2-wire Vohage Dip switch 1 --on" Dip switch 1 "oil-" 4-wire Vb" Maxhnum ripple (uric top*) kel sl 2w0he Islam! curent (6112am 4-wtne arm laonfscts Aux Relay contacts SensPofrley &hoftlectric) Perak" hhrnta renr field w>tiing sins Ihst deteder specAcatlons Rate or rise Fixed it two -wire cone 0011ltr identMer Dip switch 1 "on" Dlp switch 1 "oT DrrR oompensatla adjhntrnent Reset time Defector head dimensions Diameter Height Mounting dinhenSlons Diameter Hei9ht ulor peclang www.GE-Inleriogizcom 12345 SW Leveton Drhe 2266Seca dStreet North Tualatin, OR9&V Nanh St Paul, MN 55109 Phone:503-692.4052 Phone:651-777-2690 USA & Canada: M547.2536 USA & Canade.800.777.5484 Technical Serwce: 800.648 7424 Technical SeMce: 800.777-2624 faxbeck: M483.2495 02W3 GE k*Wogk. CkenM & ndSmoeel Inaan Oro MAWalborGE IKnrIV AO 0VW "dMWheroV0PN icedV*V ownse. E-3753,mbKA-01O3 6.5-33VDt" polarity sensitive 8.5- 33VDC, polarity sensitive 8.5- 33VDC 10%(vp-P) unnto max Ofnot limited bycontrol panel) 500mA V 36VVC (resistive) lA 4V 30VDC (resistive) 3.1% + 0.50-1.00% 327 to 1007 (0 to 37°C) 0 to 95% Non-condensingg 20V/m minimum 0-1000MHz 12-24 AM (16-22 15°F/min and >105'F (8.3TIMIA, > 40.6'C) 135°F (57'C) S094 Sim, S17A 1.0%R. max 1 second minimum 5" (127mm) 2" (51mm) 4.75" (125mm) a3" (8mm) White head and base 10 detectors per carton ® U4 CSFM, MEA (2-wire only) LEM GE Interlogix 29 A I t r o n i x I RB5-24 - Relay Module Specifications: Switch selectable 24VDC operation. Double form "C" contact rated 5 amp,115VAC/28VDC contacts. Current Draw 35 mA. Snap track mountable (order part # STI). Board dimensions: 2.75"L x 2"W x 1"H O z A (D,R O by t'ontads i polarity Reversal ' .. To BELL OUTPUT TERMINALS OF CONTROL PANEL I Latching My ILomaaS N.O. TRW sWITCN 4 - 490MANT POWER 90400 Altronix is not responsible for any typographical earns. rmsna LINE POWER Re in t1A ar70 O 4 TO BELL OUTPUT TERMINALa OF . CONTROL PANEL TO PHONE LBIE U" Seizare To ALARM TRANaMITTER O '-0 tmi NOUBE N mom A _ u a p O TELEPHONE LINE TO BELLOUTPUT TERNINALs OF _ iii CONTROL PANEL 140 38th Street. Brooklyn. New York 11220 USA, 718-567-8181. fax: 718-567.9056 web site: www.alimnix.com, e-mail: info0altronix.com. Lifetime Warranty, Made in U.S.A. IIRB5.24 - Rev. 082599 gn 1. DTK=LVLP Series Electrical Specifications Class: Low Voltage Line Protection Installation Point: Wire Entry to Building Agency Approvals: UL497B Connection Method: Screwterminals 16-22 awe wire Continuous Current: Unlimited Response Time: <5 NSec (Installed) Wiring Configuration: 2,4,6, and 8 wire Models available Prntactinn Mnrlaa- I - r_ [All linne nr %fgr4,n11 D X LV OPX SPK SGR RUV Max. Surge Current*: 2000A ZMA 2000A 2000A 9000A 9000A 9000A Max. Eneray Dissipation (Joules)*: 4 8 17 30 44 60 76 MCOV: 8VDC 118VDC 38VDC 66VDC I 102VDC 127VDc 175VDC Typical Let -Throw h Volta e: NRMS I ,svRNM 27VRM5 I 62VRMS I 75VRAWU 95vr nns aov nns Per Pair Physical Specifications Housing: High Impact Plastic Housinq Color: Black Housing- Size: 3.01" x 1.60" x 1.60" Weight: .25 lbs. Warranty Lifetime Product Replacement Warranty Revised 6/25l99 DITEK warrants this product to be free from defects in workmanship and material and to operate under normal use and conditions. If defective, DITEKwill repair or replace this unit without charge. ONE DITEK CENTER 1-800-753-2345 A= w 1720 Starkey Road, www.diteksurge.com nI TE—KeLargo, FL 33771 A DITEK LVLP SERIES 1 1• h 1Ct i 1i• l telecommunicationsAgoilcalions This device Is Intended for iridoor use on Isolated loop, data ckculft, Or low VON M7Nr 170 Mrt wt 7t Mr4 W wt i7 vtr6 13 Mwt 7 iMKS RUV SGR SPK OPX LV X DRatwrit tom. This unit must be connected In series with the equipment to be protected. 2. This Is done by connecting side #rl ' IN' wfth the Incoming wires, and connect the opposite side of the tern inol block to the equipment to be protected. 3. Always have one common ground per system to eliminate the possibilityof a differenflal In ground potentials. 4. For mounting. use double -sided tape I supplied ), or two #8 screws I not supplied ). 5. For further information or technical support pleow call 1-888-472-6100. FOR FURTHER INFORMATION CONTACT TECHNICAL SUPPORT AT 1-800-753-2345 DITEK CORPORATION, LARGO, FL LIMITED LIFETIME PRODUCT WARRANTY Thank you for choosing a DITEK surge protection product to protect your equipment. YOU will be pleased to know that DITEK products will provide you with Years Of security and protection. in fact we at DITEK are so confident of our quality that we offer you the following: LIMITED LIFETIME WARRANTY AGAINST MANUFACTURING DEFECTS:. ' DITEK warrants these surge protectors to be free of all defects of workmanship or material for the lifetime of the original purchaser, and that DITEK will repair or replace any defe(; Ne unit. 1. Proper Instalk itlon: DITEK AC surge protectors must be installed in strict accordance with DITEK's installation Instructions. Building wiring and other connections to protected equipment must conform to National Electric Code or Canadian Electric Code. A proper and sufficient ground must be provided. 2. Rehm authorization: A return authorization number must be, obtained by contacting our Customer Service Department at 1-800-753-2345 before returning the surge protector. DITEK surge protectors are designed to dissipate the damaging effects of momentary voltage spikes or other transient power surges including impulses from lightning. They, are not warranted against lightning strikes, continuous over voltage, over current nor dropped neutrals. This warranty supersedes all previous warranties and is the only warranty provided with this class of surge protector. This warranty is In lieu of all other warranties, either expressed or Implied, oral or written, Including thewarranties of merchantability and fitness for a particular purpose. This warranty becomes effective on Jan. 1, 1999 DIVERSIFIED TECHNOLOGY GROUP, INC. 1720 STARKEY ROAD LARGO. FLORIDA 33771 TOLL FREE TELEPHONE NUMBER 1.800.753.2345 mT _ 0 form 190805 FIRE PROTECTIVE SINGLE CONDUCTOR and TWO CONDUCTOR PARALLEL UL LISTED NEC TYPE FPL 105° C No more low insulation resistance. Similar to jacketed cable result, WPW New FPL rated single conductor and parallel constructions util'Ize coextrusion technol to ive the CM flame s ad (UL 1581 Vertical Tray Flame Test) required. while giving you the high- est possible insulation values. SINGLE CONDUCTOR 1. F"MoOK W imIQ TWO CONDUCTOR PARALLEL Ca No of AwG sizes : N" Nom 0 0. COLORSbald, arwov... T •• Inchkch yam, 1..: I+ inch 91$ 2 19 Solid 020 51 075 x .160 1.9111 " Red. White. Green, Orange. Brown. Blue, Blade970219SM03281104x .204 2 64 z5;g1 971 2 18 Staid 032 81 , 115 x .225 2.92 x 52 White, Fled, Blade 972 2 14 Solid 032 21 128 x .250 3.25"z`6:35' White, Red, i Blade 914 2 12 Solid 032 81 146 x .300 3.71. ci.s 1' White, Red. 1 Black STANDARD SPOOL SIZE 1000 FEET OESCWPTION ASTM Bare Copper 1050 C PVC Insulation RATING UL Listed NEC Type FPL Constructed in Accordance with UL Standard 1424 Complies with UL 1581 Vertical Tray Flame Test. Ten"reture Range 20• C to 105• C Dry Loca- tions Meets 300 volt requirement as specified in section 760-51 cc) APPLICATIONS Indoor (Noncondult per NEC) for. Power Limited Fire Protective Circuits 1KWIRE GROUP e.e+.Rc+w.ww noeuco WON Aff WESTPENN WIRE CORP. t n I Aru, ... CQNTIOL M.• •PeCu.L1Y nMwuaNC" SERIES NS/NS4 SERIES NN SERIES NS/NS4 Universal Mounting SERIES NS/NS4 Cover NEW WALL APPLIANCE (available sept'97) Series NS/NS4/NH Horn Strobe and Horn Appliances Wheelock's Newest Horn Strobe and Horn Appliances are the Series NS/NS4 Horn Strobe appliances and the Series NH Horns. Both the Series NS/NS4 and NH are LOW CURRENT designs with ZERO INRUSH. The horn appliances provide a Selectable continuous horn tone or temporal pattern (Code 3) tone when constant voltage from a Fire Alarm Control Panel (FACP) is applied. Each tone has two dBA settings to choose from. All models (horn only or horn with strobe) may be Synchronized when used in conjunction with the SM or DSM Sync Modules. Additionally, the horn may be silenced while maintaining strobe activation of the Series NS/NS4 Horn Strobe appliances. All of these features are achievable with either Wheelock's Patented 2 Wire Series NS or with the 4 wire Series NS4. Features Approvals Include: Underwriters Laboratories UL 1971 and UL.464 Listings, FCC Part 15, Pending: Factory Mutual (FM), European Community (CE), California State Fire Marshal CSFM), New York City (MEA) and Chicago (BFP) approvals on all models. ADA/NFPA/ANSI compliant. Meets OSHA 29 Part 1910.165. Low Current. Zero Inrush. Wall mount only. 2 Selectable tones and dBA levels. Continuous tone: 90 or 95 dBA anechoic; 82 or 88 dBA reverberant. Temporal Code 3 tone: 92 or 97 dBA anechoic; 76 or 82 dBA reverberant. Patent Pending Universal Mounting Plate for single gang, double gang, 4" square, 100 mm European Backboxes or Wheelock's SHBB surface backbox. No additional trim plates required. Available with 15, 15/75, 30, 75 and 110 cd strobe intensities. 2 versions available. 2-wire for both horn and strobe. 4-wire model. Non -Sync and Sync in one (synchronization requires a SM or DSM Sync Module). Matching horn in 12/24 V (Selectable). Fast installation with in/out screw terminals using #12 to #18 AWG wire size. Strobes flash at 1 flash per second. Compatible with all standard FACP's. Wh22bGit Specifications and Ordering Information WALL MOUNT ONLY Model Number* Order Code Input Volta a Strobe Candela Mounting Options" NS-2415W-FR 7805 1 24 15 B D F G X NS-241575W-FR 7806 1 24 15/75 B D F G X NS-243OW-FR 7807 24 30 B D F G X NS-2475W-FR 7808 24 75 B D,F G X NS-24110W-FR 7809 24 110 B D F G X NS-1215W-FR 7815 12 15 B D F G X NS-121575W-FR 7816 12 15175 B D F,G X NS4-2415W-FR 7900 1 24 15 B D F G,X NS4-241575W-FR 7901 24 15/75 B D F G,X NS4-2430W-FR 7902 24 30 B D F G X NS4-2475W-FR 7903 24 75 B D F G X NS4-24110W-FR 7904 24 110 B D F,G,X NS4-1215W-FR 7910 12 15 B,D F G X NS4-121575W-FR 7911 12 1 15/75 B D F G,X NH-12/24-R 7449 12/24 1 — B D,F,G X Average SYNC MODULE*** Current SM-12/24-R 6369 12 014 E,N 24 025 E,N . DSM-12/24-R 6374 12 020 W 24 038 W NOTES: Model 0 Color Is Red, can be ordered In White, Call Customer Service for order code & delivery. Model Code Suffix: W - wall, F - fire lettering or call Customer Service it other lettering is required (Ex. Feugo), R - red, W at end - white, 4.4 wire Example: NS-2415W-FRS--Red NS4-2415/W-FR t—Red ,NS-24755W-FW Whlte W/ R T '"`Fire Waif""Fire I Fire 4-lire Wa I Refer to Data Sheet S7000 for Mounting Options or page 55 of this catalog. SM Sync Modules are rated for 3.0 amperes at 12 or 24 VDC; DSM Dual Sync Modules are rated for 3.0 amperes per circuit. The maximum number of Interconnected DSM modules is twenty (20). Refer to Data Sheet S3000 and installation instructions (Refer to Fax -On -Demand List located In this catalog). WHEELOCK AVERAGE CURRENT Average Current (Amperes) 0 24 or 12 VDC Anechoic/ Reverberant dBA levels for Continuous & Temporal (Code 3) Tones Chart Key: so s Low & High odel Number Low High NS-2415W-FR 071 077 NS-241575W-FR 086 091 NS-2430W-FR 102 107 NS- 475W-FR 154 160 NS-2411OW-FA 181 187 NS-1215W-FR 137 140 N -1 1 75W-FR 172 17 Model Number Low Horn/Strobe High Horn/Strobe NS4-2415W-FR 021/.054 027/.054 NS4-241575W-FR 021/.068 027/.068 NS4-2430W-FR 021/.081 027/.081 NS4-2475W-1`11 021/.133 027/.135 NS4-24110W-FR 021/.161 027/.161 NS4-1215W-FR 010/.126 013/.126 NS4-121575W-FR 010/.162 013/.162 NH-1 4-11 010/.020 013/.027 Average current per actual Wheelock Production Testing at 10.5, 12, 15.6, 20, 24 & 31 VDC. For rated average and peak current across the UL listed voltage range for both filtered DC and unfiltered VRMS, see Table A on page 59 of this catalog or see installation instructions. Refer to fax -On -Demand List located in this catalog.) RFRIFR NS/NN DUICK REFERENCE GUIDE Model Number* Wall Mount Now Sync Sync's w/ SO or DSM Strobe Candela 24 VDC 12 VDC 2 Terminal 4 Terminal NS-2415W-FR X X X 15 X X NS-241575W-FR X X X 15/75 X X NS-2430W-FR X X X 30 X X NS-2475W-FR X X X 75 X X NS-24110W-FR X X X 110 X X NS-1215W-FR X X X 15 X X NS-121575W-FR X X X 15/75 X X NS4-2415W-FR X X X 15 X X NS4-241575W-FR X X X 15/75 X X NS4-2430W-FR X X X 30 X X NS4-2475W-FR X X X 75 X X NS4-24110W-FR X X X 110 X X NS4-1215W-FR X X X 15 X X NS4-121575W-FR X I X I X 15/75 X X NH-12/24-R** X I X I X X X X Model / Color Is Red, can be ordered in White, Call Customer Service for order code & delivery. NH-12/24 can also be ceiling mounted. SEE PAGE 3 FOR GENERAL AND TECHNICAL NOTES. N oa awr auoiY lrv wk N11Y YWGA TV Pw..IwCI Series RS/RSS Strobe Mounting Plate Shown w/o cover plate) Series RS/RSS Wall Cover Plate Included w/strobe) Wall Strobe Ceiling Strobe Series RS Strobes and New Features RSS Non-Sync/Sync Strobes Enhancements Wheelock's Series RS Strobes and Series RSS Non-Sync/Sync Strobes have been enhanced with Lower Current Draw and the Series RSS has ZERO Inrush while maintaining their outstanding performance, reliability and cost-effectiveness In meeting or exceeding the latest requirements of NFPA 72 (National Fire Alarm Code) 1996, ANSI 117.1 (American National Standard for Accessible and Usable Building and Facilities), and UL Standard 1971 (Signaling Devices for the Hearing Impaired). RS/RSS Strobe Appliances, when properly specified and installed in accordance with NFPA/ANSI Standards, can provide the Equivalent Facilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2) by meeting or exceeding the illumination which results from ADA's strobe intensity guidelines of 75 candela at 50 feet. This is an illumination of 0.030 lumens per square foot. Wheelock's Series RS/RSS Strobes employ an integral Patented Strobe Mounting Plate that makes it easy to mount to a variety of backboxes. The strobes can be mounted to single -gang, double -gang, 4" square, 100 mm European backboxes, or the SHBB backbox (Order Code 7254) for surface mounting. An attractive cover plate is provided for a clean, finished appearance on all models. Wheelock's Series RS Strobes are available with 15 and 15/75 candela intensities for Wall mount only and non -sync applications. The Series RSS Strobes NOW include Non -Sync and Sync in ONE appliance. The SM or DSM Sync Module must be used to achieve Sychronizat/on of the strobe. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. The strobe options for the Series RSS are 15, 15/75, 30, 75 and 110 candela intensities for Wall mount and 15, 30, 75 and 100 candela intensities for Ceiling mount applications. Features Series RS/RSS Strobes: Approvals Include: Underwriters Laboratories UL 1971, European Community (CE), FCC Part 15. Submitted for New York City (MEA), California State Fire Marshal (CFM), Chicago (BFP) and Factory Mutual (FM) approvals on all models. ADA/NFPA/ANSI compliant. Meets OSHA 29, Part 1910.165. LOWER CURRENT. Patented Strobe Mounting Plate for single gang, double gang, 4" square, 100 mm European backboxes or Wheelock's SHBB backbox for surface mounting. Low current draw with temperature compensation to reduce power consumption and wiring costs. Polarized 12 and 24 VDC models with wide listed voltage ranges using filtered DC or unfiltered FWR Input voltage. Fast installation with IN/OUT screw terminals using #12 to #18 AWG wires. Series RS: Low Current 24 Volt only. Wall mount only. Available only In 15 and 15/75 candela intensity. Series RSS Strobes: Low Current ZERO INRUSH. Both Non -Sync and Sync in ONE appliance. To achieve Synchronization, a SM or DSM Sync Module must be used. 12 or 24 volt models. Wall mount RSS available In 15, 15/75, 30, 75 and 110 candela intensity. Ceiling mount RSS available In 15, 30, 75 and 100 candela intensity. WM3T Since the inception of UL 1971, strobes cannot be Listed for outdoor use, Wheelock offers WM3T strobes for outdoor installation requiring weatherproof devices and private mode operation where UL 1971 strobes are not required. They are UL 1638 Listed at 117 cd and are designed for surface mounting indoors or outdoors. NOT TO BE USED AS IN INDOOR VISUAL EVACUATION SIGNAL OR FOR THE HEARING IMPAIRED" ONLY 88 MILLIAMPS 20-31 VDC 18 WIIPR.kCIC Specifications and Ordering Information WALL MOUNT STROBES — SERIES RS/RSS Model Number* Order Code Input Voltage VDC StrobeCurrent Candela Average** DAMPS) 0 24 VDC Mounting Options*** RS-2415W-FR 7465 24 15 050 B,D,F,G,X RS-241575W-FR 7466 24 15/75 065 B,D,F,G,X RSS-2415W-FR 7470 24 15 050 B D F G X RSS-241575W-FR 7471 24 15/75 065 B,D,F,G,X RSS-2430W-FR 7472 24 30 081 B,D,F,G,X RSS-2475W-FR 7473 24 75 133 B D F G X RSS-24110W-FR 7474 24 110 161 B,D,F,G,X RSS-2415W-FW 7787 24 15 050 B,D,F,G,X RSS-241575W-FW 7788 24 15/75 065 B,D,F,G,X RSS-1215W-FR 7475 12 15 126 B,D,F,G,X RSS-121575W-FR 7476 12 15/75 161 B,D,F,G,X CEILING MOUNT STROBES — SERIES RSS RSS-2415C-FW 7482 1 24 15 067 B,D,F,G,X RSS-2430C-FW 7483 24 30 102 B,D,F,G,X RSS-2475C-FW 7484 24 75 204 B,D,F,G,X RSS-24100C-FW 7485 24 100 238 B,D,F,G,X SYNC MODULE SM-12/24-R 6369 12 014 E N 24 025 E N DSM-12/24-R 6374 12 020 W 24 038 W SM Sync Module Is rated for 3.0 amperes at 12 or 24 VDC; DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM modules Is twenty (20). Refer to Data Sheet S3000 or installation instructions (refer to Fax -On -Demand list in this catalog). Use the Series RSS appliances for synchronization. Series RS-Wall, RSS-Wall and RSS-Celling are available in either Red or White. Please contact Customer Service fororder codes (if not stated above) and delivery information. Model code suffix: W - wall or C - ceiling; F . fire lettering or call Customer Service If other lettering Is required (Ex.: Feugo). R at end - red plate; W at and - white plate; Example: RSS-2415W-FR .*-Red RSS-2415W-FRW --*-'White RSS2415C-FW O"hite Wall Wall -*, "Flre Ceilinev, 'WqNre Average current per actual Wheelock Product Testing 0 10.5. 12, 15.6, 20, 24 & 31 VDC Nominal Voltage. For rated average and peak current across the UL Listed voltage range for both filtered DC and unfiltered (VRMS). Use Table E for Series IRS or Table F for Series RSS wall or Table G for RSS ceiling when calculating current requirements located on page 51 of this catalog and/or most current installation Instructions. (refer to Fax -On -Demand Listing In this catalog). Refer to Data Sheet 37000 for Mounting Options or page 56 of this catalog. Note: WM3T-24-VFR - UL 1638 only. Refer to installation instructions (P82037). 117 cd STROBE INDOOR OR OUTDOOR must use WBB box for outdoor Input Average Order Voltage strobe Current Model Number Code VDC Candela AMPS Mounting Options WM3T-24-VFR 4911 24 117 088 J,K SERIES RS and SERIES QUICK REFERENCE GUIDE t ii iiiiiii i: iiiisE ifiiiiiiiii 11 t 11 iiiiisE:_11 iiiiiiiiiii il r 11 iiiiiiii iiiiiiiiii Model # Color Is Red, can be ordered In White, Call Customer Service for order code & Delivery. Model / Color is White, can be ordered in Red, Call Customer Service for order code & Delivery. SEE PAGE 3 FOR GENERAL AND TECHNICAL NOTES. uuheelock 19