HomeMy WebLinkAbout1295 W Airport Blvd - BC08-000592 (Install New Semi-Rec Heads) DocumentsCITY OF SANFORD PERMIT APPLICATION
Application #: O / Submittal Date: 1 / 7 / 0 8
Job Addressi 295 W. AIRPORT' Value of Work: $ 3,489.00
Parcel ID: 02-20-30-300-034A-0000 Zoning: Historic District:
Description of Work: INSTALL NEW SEMI RFC HEADS DOWN TO Wgj§gtegfe f kage:
Permit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm IN Pool Sign
Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential Replacement New (Duct Lavout & Energy Cale. Required)
Plumbing/ New Commercial: # of Fixtures of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair —Residential Commercial
Occupancy Type: Residential Commercial Industrial Occupancy Use Group(s):
Construction Type: # of Stories: of Dwelling Units: Flood Zone: (FEMA form required )
Property Owner:
I.........
Contractor: SOUTHERN FIRE PROTECTION,
Address: Address: 3801 E. ST RD 46
SANFORDf FL. 32771
Phone: E-mail:
74072300011990
Phone: 3 2 3— 4 2 0 0 State License Number:
Bonding Company:
Address:
Architect/Engineer:
Address:
Plan Review Contact Person:
Mortgage Lender:
Address:
Phone: Fax:
Phone:
Fax:
E-mail:
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate
permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS. TANKS, and
AIR CONDITIONERS, etc.
OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE 10B SITE BEFORE THE
FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of
this county; and there may be additional permits required from other governmental entities such as water management districts. state agencies, or federal agencies_
Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713.
Signature of Owner/Agent Date Signature of ContractoV ni Date
ROBERT H. CALDWELk JR.
Print Owner/Agent's Name rut Contractor/Agent's Na
Signature of Notary -State of Florida
Owner/Agent is _ Personally Known to Me or
Produced ID
APPROVALS: "ZONING:
Special Conditions:
Rev 07.07
Date ignat re of Notary -Slate of Florida
Contractor/Agent is
Produced ID
UTIL: FD: ENG:
ELMETH T. PERKINS
Notary PIJ* - State of Florida
PQ{rrt Expires Jan 23, 2009
Commission # DD 388798
BLDG:
001.00
LIMITED POWER OF ATTORNEY
Building Department
January 7, 2008
4 /
I hereby name and appoint:
Steven Cohen Printed Name of Appointee
Southern Fire Protection of Orlando, Inc. Company Name of Appointee
To be my lawful attorney -in -fact to act for me in submitting and receiving
Commercial/Residential Permitting, and to do all things necessary to this appointment.
Joey D's Jerky Project Name
1295 W. Airport Blvd Project Address
51176 Our Job #
02-20-30-300-034A-000 Parcel ID#
Signed:
By: Robert H. Cal ell, Jr.
President
License #74072300011990
Sworn to and subscribed be a this 7 day of January , 2008
by Robert H. Caldwell Ji is personally to me.
No a Public
My C mmission Expires:
R "4q•• ELIZABETH T. PERKINS
Notary Public - State of nwida
1W Cww sfon Expires Jan 23. 20 99
Z n, Commission 0 W 386798
FROM :Design Enterprises, Inc. FAX NO. :407 830 8448 Jan. 07 2008 02:57PM P2
w u nut q1 II III I SIN
Instrument Prepared bpPY 1 WYMNE Milfi8{: MOK W Qf kL'UIT LWHTSeminc.e County Comptroller's nflict'""IWLC 1rOgl 6k's IlseName: Elaine Miller
Design Enterprises, Inc.
OnlyAttn: Official Records " 06817 PP 00771 I44l
815 Orienta Ave., #I040
Altamonte Springs
CLERK'S # 20O71,;:gt32 Rt:'
4YlliUarU 05/Iw/ kw-j FL327010.413'/; 11 PR RISCUK1ltNliIt;t 510.00 Wpm*!)
BY 11 UeVore Permit #
Tax
Folio # %e nxl Pl Nfi Mra NOTICE
OF COMMENCEMENT MARYANNE MOOSE STATE
OF FLORIDA CLER F IRCun' I',nURfi COUNTY
OF SEMINOLI SE IN Ty. FLORIDA 8Y
05 m" rt r K THE
UNDERSIGNED hereby gives notice that improvement will be made to certain r qy- property, and in accordance with. Chapter 713, Florida Statutes, the following informatit7n issprovidedinthisNoticeofCommencement, 1.
Description of property: (legal description of property and street address, if available: 1295
Airport Boulevard, Sanford, Florida Parcel
I.D. #02-20-30-300-034A-0000 2.
General description of construction: interior build -out (Joey D's) 3.
Owner Information: a.
Brio, Lf,C Phone: (407) 830-1.414 815
Orienta Avenue, Suite 1040 Altamonte
Springs, Florida 32701 Fax: (407) 830-8448 b,
interest in property: C.
Name & Address of fee simple titleholder (il'other than owner): 4.
Contractor (name and address): Design
Fnterprises, Inc. Phone: (407) 830-1414 815
Orienta Avenue, Suite 1040 Altamonte
Springs, Florida 32701 Fax: (407) 830-8448 5.
Surety: a.
Name and address: b. Amount of Bond: 6.
Lender (name and address): Florida Choice Bank 1000
Legion Place, Suite 100, Orlando, Florida 32801 7.
Persons within the State of Florida designated by Owner upon whom notices or other documents
may be served as provided by Section 713.1.3(1)(a)7, Florida Statutes: 8.
In addition to himself, Owner designated the following person(s) to receive -it copy of the Lienor'
s Notice as provided in Section 713.13(1)(b), Florida Statute: 9.
Expiration date of Notice of Commencement.(the expiration date is one (1) year from the date
of recording unless a different date is specilied). Date*-
atCt 1Q11Aen A. e*erana8iaer Sworn
to and sub cribbed before me t is of
tM1ar Py¢ WINE V. MILLER 1 *
MY COMMISSION f DO 51DR3 EXPIRES:
Ap D 11, 2010 11
h.,,"„
v'.° B6ide6 Thru Roget Notiq Sff ss rp,binatureof Notary Public Notary
Public Name; Notary'
s Commission .xpires: ALL
INFORMATION MUST BE TYPED OR PRIN117,D LEOMLY TO COMPLY WITH RECORDING REQUIItL+MFNTS.
Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 2
Personal Property Please Select Account p 1'tY .
RA'
DAV ID JOHAISUN,CFA. IASA
S'Eiv71NQLE {7QUhtfY;FL.:
s s
1101' FlR5T;,57
SAItF06iD. FL 32Z71-1 d66'
407-H65 '7.sUB•
2008 WORKING VALUE SUMMARY
Value Method: Income
GENERAL Number of Buildings: 2
Parcel Id: 02-20-30-300-034A-0000 Depreciated Bldg Value: $0
Owner: BRIO LLC Depreciated EXFT Value: $0
Mailing Address: 815 ORIENTA AVE STE 1040 Land Value (Market): $0
City,State,ZipCode: ALTAMONTE SPRINGS FL 32701 Land Value Ag: $0
Property Address: 1105 AIRPORT BLVD W Just/Market Value: $2,849,132 *
Facility Name: BRIO BUISNESS CENTER Assessed Value (SOH): $2,849,132 *
Tax District: S1-SANFORD Exempt Value: $0
Exemptions: Taxable Value: $2,849,132
Dor: 1702-FLEX SPACE Tax Estimator
Tax Reform Calculator
Income Approach used.)
SALES
Deed Date Book Page Amount Vac/Imp Qualified
2007 VALUE SUMMARY
TRUSTEE DEED 06/2005 05768 1222 $675,000 Vacant No
unt_; 2007._Tax BilbleQUITCLAIMDEED07/1996 03098 0864 $10,000 Vacant No V 817$
52,
3692007TaxableValue: $2,817,369
QUIT CLAIM DEED 04/1995 02908 1057 $100 Vacant No
DOES NOT INCLUDE NON -AD VALOREM
QUIT CLAIM DEED 03/1995 02908 1055 $100 Vacant No ASSESSMENTS
WARRANTY DEED 01/1974 01006 0486 $157,500 Vacant Yes
Find Sales within this DOR Code
LEGAL DESCRIPTION
SEC 02 TWP 20S RGE 30E W 1/2 OF W 1/2
LAND LYING NELY OF SR 417 & SWLY OF
Land Assess Land Unit Land AIRPORT BLVD & S OF OLD
Method
Frontage Depth
Units Price Value LAKE MARY RD (LESS CSX RR R/W IN NW
SQUARE FEET 0 0 311,454 3.00 934,362 1/4 SW OF AIRPORT BLVD & LESS THAT
PART OF LOT 45 LYING SWLY OF
AIRPORT BLVD AVONDALE PB 3 PG 94)
BUILDING INFORMATION
Bid Year Gross
Bid Class Fixtures Stories
Est. Cost
Ext Wall Bid Value NewNumBitSF
1 MASONRY 2006 39 30,380 1
CONCRETE BLOCK -STUCCO - $1,624,242 $1,665,889
PILAS MASONRY
Subsection / Sgft CANOPY / 2170
STEEL/PRE 2006 18 20,400 12 FACE BLOCK - MASONRY $600,135 $618,696
ENG
Subsection / Sgft CANOPY / 1275
Permits
http://www. scpafl.org/web/re_web.seminole_county_title?parcel=022030300034A0000&cf... 1 /2/2008
Model F1 FR Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall
HSW 1 Deflector
Model F1 FR Recessed Sprinkler Types
Recessed Pendent
Recessed Horizontal Sidewall
HSW 1 Deflector
Listings & Approvals
1. Listed by Underwriters Laboratories, Inc. (UL)
2. Listed by Underwriters' Laboratories of Canada (ULC)
3. Certified by FM Approvals
4. Loss Prevention Council (LPC, UK)
5. NYC BS&A No. 587-75-SA
6. Meets MIL-S-901C and MIL -STD 167-1
7. Verband der Schadenversicherer (VdS, Germany)
8. NYC MEA 258-93-E
UL Listing Category
Sprinklers, Automatic & Open
Quick Response Sprinkler
UL Guide Number
VNIV
Patents: US Patent No. 6,374,920 Applies to
Model F1FR Vertical Sidewall Sprinklers.
Product Description
Reliable Models F i FR and F1 FR Recessed Sprinklers are
quick response sprinklers which combine the durability of a
standard sprinkler with the attractive low profile of a decorative
sprinkler.
The Models F1 FR and F i FR Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers. This
quick response enables the Model F1 FR and F1 FR Recessed
sprinklers to apply water to a fire much faster than standard
sprinklers of the same temperature rating.
The glass bulb consists of an accurately controlled amount
of special fluid hermetically sealed inside a precisely manu-
factured glass capsule. This glass bulb is specially con-
structed to provide fast thermal response. The balance of
pals are made of brass: copper and beryllium nickel.
At normal temperatures: the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid ex -
Bulletin 136 Rev.O
Model F1 FR
Model F1 FR Recessed
Quick Response
Sprinklers
Upright Pendent
Vertical Sidewall Conventional
Horizontal Sidewall Recessed Pendent
HSW 1 Deflector (Model FP Shown)
pands, forcing the bubble smaller and smaller as the liquid
pressure increases. Continued heating forces the liquid to
push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
Application
Quick response sprinklers are used in fixed fire protec-
tion systems: Wet, Dry: Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating; deflector
style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Asso-
ciation or the approving Authority Having Jurisdiction.
Quick, response sprinklers are intended for installation as
specified in I\IFPA 13, I'M Global Loss Prevention Data
Sheet 2-81\1 or other applicable standards. Quick response
sprinklers and standard response sprinklers should not be
intermixed.
The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523
J
z
0
X
Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
K Factor S nnkler Identification '
S rinklerT Sprinkler i Approval p
p Ypa Number SINL -' US Metric Height Organization -- ---
SSU SSP_
Standard -Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Pnsitinn —
T
15mm) Standard Orifice with IVFT (R ) l hread 5..6 80 2 2 (n6mm) 1 2 ° 4 5.G 7 R3626(" R3615
arge Orifice with_ NPT R':)Thread_ 8.0 i 15 2 3 (58mm) 1 3 4 7 8 R3617
17mm) Small Orifice with NPT (R ,) Thread— 4.2-- 60 2.2' (56mm) 112.8
R3672"'
R362J''' R3613
10mm) Small Orifice with :J" NPT (R'.,) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621 R3611
Omit: Orifice XLH with R" Thread 4.2 60 56mm 4,6,7 R3624 R3614
Uonventional-install in
1Gmm OriticE KLN Math P thread I 4.2
15n m Standard Orifice with " NPT (R ;) Thread 5 6
20mm Large Orifice with Y " NPT (R"i )Thread S.0
Polyester coated upright UL and ULC lister) corrosion resistant
Jprr ht or Pendent Position
60 56mm — R3674
80 56mm 4 6 r R3675
115 58mm 4,7 R3672
uprlgnt Pendent Conventional
Model F1 FR Quick Response Recessed Pendent Sprinkler
Installation Wrench: Model GFR1 Sprinkler Wrench
Installation Data:
Nominal Thread K Factor Sprinkler Approval'' Sprinkler IdentificationOrificeSizeUSMetricHeightiOrganizationsNumber (SIN)
ornm) -- NPT (R' ii — 5 6 30 56mh) 1 2 3 15 i 8 R3615
limn,) Nf I (R:,,',) F O I 1 2' (Smrn) 1 2 0 -- 3612 j
11mr) IPitR'-:' 42 6 2"(56mm) 12.8 Ri6i3
10mr) 2.8 40 2 2" (56mm) R3611
Ornm R'. — — 4.2 60 56mm 4.7 R3614
Refer to escutcheon data table for approvals and dimensions
2.
I Model F1FR Quick Response Vertical'Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installatinn Data•
Nominal Thread K Factor
Sprinkler Approval Sprinkler
Orifice Size HeightUSMetricg Organizations Identification
Number (SIN)
NPI" (R'r
I ..._...._ 5.6 80 2.2" (56mm) 1 11 2: 3, 6, 8
15mm fvPT (R :) 5.6 80 2.2• (56mm) 4
R3685
LPC Approval is for Pendent position only.
Orientation Deflector to Ceiling
Dimension (Min. - Max.)
Upright __ i—__ 4" - 12" (102mrn - 305mm
Pendent 6" - 12" (152mm - 305rnm)
Vertical Sidewall
US Patent No. 6,374,920
Model F1 FR Quick Response'Horizontal Sidewall Sprinkler
Deflector: HSW 1
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Approval Organizations
K Factor and Type of Approval Sprinkler
Nominal Thread
Orifice Size US Metric
Sprinkler
Length Light l Ordinary iNumberIdentification
SIN)
Hazard Hazard
16mm ....5 6 80 2 63 (67mm) 1,2,3,5,8 1,2 5 8 R3635
NOTE: UL. ULC and MEA Listing permits use with F 1 or r 2 recessed escutcheon.
Horizontal Sidewall
Installation
Quick response sprinklers are intended for installation as
specified in NFPA 13, FM Global Loss Prevention Data Sheet
2-8N or other applicable standards. Quick response sprin-
klers and standard response sprinklers should not be inter-
mixed.
The Model F1 FR Recessed Quick Response Sprinklers are to
be installed as shown. The Model F1 or F2 Escutcheons illus-
trated are the only recessed escutcheons to be used with the
Model F1 FR Sprinklers. The use of any other recessed escutch-
eon will void all approvals and negate all warranties.
When installing Model F1 FR Sprinklers, use the Model D Sprin-
kler Wrench. When installing Model F1 FR Recessed Pendent or
Sidewall Sprinklers: use the Model GFR1 Sprinkler Wrench. Any
other type of wrench may damage these sprinklers.
Glass bulb sprinklers have orange bulb protectors to minimize
bulb damage during shipping, handling and installation. RE-
MOVE THIS PROTECTION AT THE TIME THE SPRINKLER
SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re-
moval of the protectors before this time may leave the bulb vul-
nerable to damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE PROTECTORS
BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS
TO REMOVE THE PROTECTORS.
Temperature Ratings
Sprinkler
Classification ! Temperature Max. Ambient ! Bulb
C op Temp. Color Ordinary
57 13F. j ICYTF;38`C) Orange Ordinary
68 155 100'F(38 C) Red Intermediate
79 175 1501F (661C) yellovv lnternediate
93 200 1501F(66°C) Green Higr,
r'' 141 286 2251F(1071C) ! Blue Not
available for recessed p inl.ler . Escutcheon
Data Escutcheon
A„ Face of Fitting Approvals
Adjustment ModelDimension to Ceiling or Wall
Dimension F1
2 Max Recess(30 lnur) c,'
4.
8 Min
Re m 1-2 mn') t
tnlrr) 1;
F?_
1,2,3,407,8' Max Recess(38 1mrn) 1?mrm MinRecessSnn24mrn
cp
1.2 Max Recessed I '" (33.1rrmrri) 11mmi
jPushon/ Thread -
off 12 Min Recessed P4mm
lo4rnlrt)
No
Dii-neinsionai Figure for FP Maintenance
The
Models F1 FP, and F1 FR Recessed Sprinklers should
be inspected quarterly and the sprinkler system maintained
in accordance with NFPA 25. Do not clean sprinklers
with soap and water, ammonia or any other cleaning
fluids. Remove dust by using a soft brush or gen- tle
vacuuming. Remove any sprinkler which has been painted (
other than factory applied) or damaged in any way.
A stock of spare sprinklers should be maintained to allow
quick replacement of damaged or operated sprin- klers.
Prior to installation, sprinklers should be maintained in
the original cartons and packaging until used to mini- mize
the potential for damage to sprinklers that would cause
improper operation or non -operation. Sprinkler
Types Standard
Upright Standard
Pendent Conventional
Sidewall (
Vertical, Horizontal HSW1) Recessed
Pendent Recessed
Horizontal Sidewall HSW 1 Finishes "' "
J Standard
Finishes Sprinkler
Escutcheon Bronze
Brass Chrome
Plated I Chrome Plated (31 white
Polyester Coated'a` White Painted''' Special
Application Finishes Sprinkler
Escutcheon Bright
Bras Bright Brass Black
Plated Black Plated Black
Paint Black Paint IOff
White Off White Satin
Chrome Satin Chrome i
t,
i Other finishes and colors are available on special order. Consult
the factory for details. 2)
FM Approvals is limited to bronze and brass, chrome or black plated
finishes only. 3)
FP P!Ish-on/Thread-off escutcheon. UL
and ULC listed corrosion resistance. SIN
numbers: R3621, R3622, R3623, R3625. Note:
For /" orifice pendent FM approved white polyester
coated and UL approved white polyester corrosion
resistant sprinklers refer to Bulletin 014. Ordering
Information Specify:
1.
Sprinkler Model 2.
Sprinkler Type 3.
Orifice Size 4.
Deflector Type 5.
Temperature Rating 6.
Sprinkler Finish 7.
Escutcheon Type 8.
Escutcheon Finish (where applicable) Note:
When Model F1 FR Recessed sprinklers are ordered,
the sprinklers and escutcheons are packaged separately.
The
eruipmeni presented in IN h'dieon is :a be installed in accordance vdith the lalast I:,ariinent st?nd, rd, ni tile, Naiio;lal Fire Pro;ecliorl ;,,oci ii(in. Faclory M;;iu ;l Ha;earcl, I;
ri +,I Ct 1@r Sirr ll :r;+r..-,loin:; arrf al>u'..iih htf ,: ovisrir;, ail Gr; r l un: iir. r udl.- c. a ppfi:-t.J :.. P.
n I I I PI '.If Ire( and (I --A rr-n Le-. by Reliahle have erl pros (I lr I [afrlc I I iJ r`•y icx. 80 "', and al e.. inslallecJ,;tlr' ;'?,..I ed by ,ll-r mosi. highI nnkle; ,.
0 :r,. Clnr In„ir, terl li rOugllrJ;l Oil, r d S ,,;. ..,: la. •; and f i. eiu 1 co-iluri. ,. Manufactured
b`d It
le a ED e The
Reliable Automatic Sprinkler Co., Inc. Jrl)
c'a t al Fax I,
1 jco 201..' Corporaitg Offices
Features .
1. The Model F3QR sprinkler utilizes Belleville Spring
Closure Technology. Reliable is the first in the
industry to produce a Quick Response Dry
Concealed sprinkler utilizing this technology.
2. Styles available
Pendent
Recessed Pendent
Concealed
Horizontal Sidewall
Recessed Horizontal Sidewall
3. 1'/Y (38mm) escutcheon adjustment on pendent
sprinkler.
4. 1/Y (13mm) escutcheon- adjustment on recessed
sprinkler with push -on/ thread -off FP Model
Escutcheon ring.
5. %" (9.5mm) cover plate adjustment on concealed
sprinkler with push-on/thread-off CCP Cover Plate.
6. Attractive appearance. Employs 3mm frangible
glass bulb and galvanized nipple.
7. Lengths available to accommodate installation
dimensions from 2' - to - 48" (51 mm - to-1219mm),
in (6mm) increments.
8. Available in a variety of plated and painted finishes.
U.S. Patent Numbers 5,775,431 and 5,967,240.
Approvals
1. Listed by Underwriters Laboratories Inc. and
UL Certified for Canada (ct Jl us)
Style Response S ystern TMSprinkler
Hazard Pendent
Recessed
Pendent CCP
Concealed R5714
Quick I
Wet
Pipe D
ry Pipe All
Preaction Light
ary
IOrdinaryI,
HorizontalSidewallRecessedHorizontal
Sidewall R573
2.
Certified by FM Approvals Style
Response nee :,' r ;1e Hazard
Lig
Pendent
Wet Pipe, O
dinary R5714)
Quick Single Interlock Groups PreactionHorizontal
Sidewall Wet Pipe, I (
R5734) Quick Single Interlock Light Preaction
3.
NYC MEA 258-93-E Bulletin
157 Re,.F Model
F3QR Quick
Response Dry
sprinklers ir .
s t
b
Concealed
a
4
Recessed
Pendent Pendent
Horizontal
Sidewall M
The
Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Model F3QR Dry Pendent Sprinkler
A" Dim. _ 2'to 4g (51mm to 1219rrm) in l/4' (6rrm) increments
Finishes"'
Sprinkler Escutcheon
Bronze Brass
Chrome Plated Chrome Plated
White Painted'' White
Other finishes and colors are available on special order.
Consult factory for details.
White painted sprinklers will have chrome plated cans.
Standard Temperature Ratinas
Sprinkler
Temperature Max Bulb
Classification Rating AmbientTem . Color
Ordinary 135-F (57-C) 100-F (38-C) Orange
Ordinary 155-F (68-C) i 100-F (38aC). Red
Intermediate 200-F (93-C) i 150-F (66oC) Green IHigh286oF141-C 225'F 107*C Blue
Sprinkler Guard: Model C-2
Sprinkler Installation Wrench
Model G3 Sprinkler Wrench
Sprinkler Identification Number (SIN): R5714
Inlet Protrusion Elevoted
Above Inside Pipe
System Tee
2 1/18" Mo. I I• NPT
54A0—]
A Dimension Hole Ceiling
Adjustment Ronye
1/4• (".. 1 43/64• Dia.
1 1/4' [-31.8mm] (42.5mm) /2' (38.1mml
Tot
Sprinkler Can '---,
Criling , 1 1/a• (31.5mm)
Escutcheon ----- E cutchean
i CeBmg -C- Adjustment
1 5/8"
Nominal POSition
14,.3mm] of Escutcheon
1/4• [6.4mm]
Protrusion 3• Dia
76.2mm] 157FGd I-c
Note: The sprinkler Can protrudes 1/4" when escutcheon is
in nominal position. Escutcheon adjustment pro-
vides +'/4" (+6mm) to -11/4" (-32mm) "A" dimension
adjustment range.
Model F3QR Dry Recessed Pendent Sprinkler
j"A"Dim. ! 3/"to49 (89nmto1219mm)in14"(6rrm)increments j Finishes"'
Sprinkler
j Escutcheon Bronze
Brass Chrome
Plated I Chrome Plated White
Painted I White Other
finishes and colors are available on special order. Consult factory
for details. Cup remains unfinished. Only the escutcheon will
contain desired finish. Standard
Temperature Ratings Sprinkler
Temperature
Max Bulb Ordinary
135T (57C) I100aF (38aC) Orange Ordinary
155-F (68-C) 100oF (380C) Red IntermediateIntermediate
200-F (93-C) 150-F (66oC) jGreen High'
2861F (141'C) 225T (1070C) 1Blue Listed
and Certified only by cULus Sprinkler
Installation Wrench Model
G3 R/C Sprinkler Wrench Sprinkler
Identification Number (SIN): R5714 2.
z
Inlet
Protrusion Elevated 'I-- , _t r-1 Above
Inside Pipe 9 I, - t —I--# -- -
c '
t ,
System
Tee i
2 1/2" Dio. 11" NPT 63.
50mm] A"
7mension Hole
Ceiling Adjustment
Ronae t1/
4" 2 19/64" Dla. t6.
35mm] [58.34mm] Nominal
Position of
EsCulCheon I
Sprinkler Cup
Assembly i '
Ceiling
4-0 I Escutcheon V
Ceilinq
1/
4" [6.35mm] J Escutcheon
Adjustment 1/
4" [6.35mm] 3 7/32" Did. Escutcheon
Adjustment 81.76mm] 1/
2 [12.7mm]. Total
Adjustment 157F002-C Note:
Do not install the Model F3QR Dry Pendent Recessed
Sprinkler in ceilings which have positive pressure
in the space above.
Model F3QR Dry Pendent Concealed Sprinkler
A" Dim. 3% ° to 48"(89rrm to 1219mn) in "/4" (6mm) increments I
CCP Cover Plate(') Finishes(
2)
Standard Finishes Special Application Finishes
Chrome Plated Bright Brass Plated
White Black Plated
Black Paint
Off White
Satin Chrome
Utilizes the }Z° cover plate with %' total adjustment.
Other finishes and colors are available on special order.
Consult factory for details.
Standard Temperature Ratinas
Sprinkler
Temperature Corer Plate Max
Classi kmtion Rating Temp. Rating Ambient Temp.
Ordinary 135-F (57aC) 135-F (57aC) 100-F (38aC)
Ordinary 155T (68aC) 135oF (57aC) 100-F (38aC)
Intermediate 200OF (930C) 165OF (740C) 150OF (660C)
High* 286aF 1410C 165-F 74aC 150-F (66oC)
Listed and Certified only by cULus.
Sprinkler Installation Wrench:
Model G3 R/C Sprinkler Wrench
Sprinkler Identification Number (SIN): R5714
Intel Protrusion Elevated
Above Inside Pipe
System Tee
1" NPr
2 1/2" D;a.
6.35mm]
A" Dimension Hole in Ceiling
Adjustment Range
2 19/64" Dio. t 3/16"
t4.76mm] 58.34mm]
Nominal Position
SprinklerofCoverplate
Cup Assembly
Coverplote
Ceiling Assembly
Ceiling
3/16" (4.76mm] I I' Coverplate Adjustment
Note: Do not install the Model F3QR Dry Pendent
Concealed Sprinkler in ceilings which have
positive pressure in the space above.
Model F3QR Dry Horizontal Sidewall Sprinkler
1 "A" Dim. 2" to 48" (5lrrvn to 1219rrm) in 1/4" (6mm) increments
Finishes")
Lqprinkler I Escutcheon _
Bronze Brass
Chrome Plated Chrome Plated
White Painted" White
Other finishes and colors are available on special order
Consult factory for details.
21 White painted sprinklers will have chrome plated can.
Standard Temperature Ratinas
Sprinkler
Temperature Max Bulb
Classification Rating Ambient Tem . Color
Ordinary 135oF (57aC) HOOT (38aC) ! Orange
Ordinary 155oF (68aC) 100-F (38aC) ':. Red
Intermediate 200-F (93°C) 150T (66oC) Green
IHigh 286aF (141aC) 1225T (107C) ;Blue
Sprinkler Installation Wrench:
Model G3 Sprinkler Wrench
Sprinkler Identification Number (SIN): R5734
91
tTt
otot
Adjustment r,.----_---
9--.---- Ce;l;n i
r ----- r L
3- 4" [101.60—] Min. 1
1/4" (31.75mm] 12" [
304.80mm] Max Escutcheon
Adjustment _ r _1 1/4" [6.35mm] System
Tee I _ 1 Escutcheon, Adjustment 1"
NPT. r
2 3/32' I 1- r' x "I [53. 18mm] a
3" 76.
20mm] 53.
98mm] ' 3 Hole
Wall t"J 1/
4" [6.35mm) 5
kler Can Protrusion
prin
Dimension
AdjustmentNominal Position rsvca.-
c Range + 1/4" [+6.35mm] of Escutcheon Note:
The sprinkler Can protrudes'/4' when escutcheon is in
nominal position. Escutcheon adjustment pro- vides +
1/4" (+6mm) to -11/4" (-32mm) "A" dimension adjustment
range.
Model F3QR Dry Horizontal Recessed Sidewall Sprinkler
At' Dim. 1 31/2."to48" 89rrm to 1219rrm in'A 6-rm ircBTents
Finishes("
Sprinkler Escutcheon
Bronze Brass
Chrome Plated Chrome Plated
White Painted White I
Other finishes and colors are available on special order. Consult
factory for details. Cup remains unfinished. "See page 2"
Standard Temperature Ratings
Sprinkler
T m Max
Classification Rahn Ambient Temp. Color
Ordinary 1351F (57-C) 1001F (381C) Orange
Ordinary 1551F (681C) 1001F (381C) Red
Intermediate 2001E (931C) 1501F (661C) Green
L High* I 2861F (1411C) 2251E 1071C Blue
Listed and Certified only by cULus.
Sprinkler Installation Wrench:
Model G3 R/C Sprinkler Wrench
Sprinkler Identification Number (SIN): R5734
Technical Data:
Orifice Size:
1/
2" (15mm)
Thread Size: 1" NPT per ANSI 82.1
Working Pressure: 175 psi (12 bar)
Nominal K Factor - US / (Metric): 5.6 / (80)
Product Description
Reliable Model F3QR Dry Sprinklers are quick response
sprinklers utilizing a durable 3mm frangible glass bulb. This
quick response enables these sprinklers to apply water to a
fire much sooner than standard response sprinklers of the
similar temperature rating.
Model F30R Dry Sprinklers are intended for use in enclosed
dry and preaction systems and in enclosed areas subjected
to freezing temperatures, such as freezers and unheated
portions inside buildings.
Environments wherein dry sprinklers are employed can be
corrosive. For this reason, Model F3 Sprinklers have a special
wax fillet placed in the gap between the cup that supports the
bulb and the wrenching boss. This wax will not interfere with
the operation of the sprinkler, and it prevents contaminents
from entering the internal portion of the drop nipple. The wax
must not be removed.
Operation
The glass bulb consists of an accurately controlled amount
of special fluid hermetically sealed Inside a precisely
manufactured glass capsule. This glass bulb is specially
constructed to provide fast thermal response. When the
temperature increases sufficiently, due to a fire, the bulb
shatters allowing operating parts to clear the waterway. This
enables the inlet seal to release air or water and subsequently,
cause water flow over the deflector in a uniform spray pattern,
controlling or extinguishing the fire.
4
1 ,3/37-
Escutcneon (35.7mmm l
SnmteTee Cup 12• (3oA.8mm]Mes.# t-
NPT w+ _ _ _ _ _ _. _
3 7/32- Did. 63.
5mm] Hot.Wou j 58.
3mm] A•
Dimension 1/
2• [12.7mm) Adjustment
Ronge Escutcneon
Adjustment 157FOO .
1/2. -0 r
12.7mm -0] FOR
FACTORY MUTUAL (FM) A -
6- FOR UNDERWRITERS LABORATORIES (UL) Notes:
Do not install the Model F30R Dry Horizontal Recessed
Sidewall Sprinkler in walls which have positive
pressure in their side space. Listed
by cULus for Quick Response. Approved by
FM for Standard Response. Recessed
Horizontal sidewall sprinklers are listed with
cULus for installation of min. 4" (100mm) - to - max.
6" (150mm) below ceiling and approved by FM
for installation of min. 4" (100mm) - to - max. 12" (
300mm) below ceiling. Ordering
Information Specify:
1.
Sprinkler Type (select one): a)
Model F30R Dry Pendent b)
Model F3QR Dry Recessed Pendent c)
Model F3QR Dry Concealed Pendent d)
Model F3QR Dry Horizontal Sidewall e)
Model F3QR Dry Recessed Horizontal Sidewall 2.
Sprinkler Temperature Rating. 3.
Sprinkler Finish. 4.
Cover Plate/Escutcheon Finish. 5.
Length: A"
Dimension (face of tee to face of ceiling or wall) in '
A" (6mm) increments. 6.
Model F30R Dry Pendent (a) is available without sprinkler
can and escutcheon. Note:
1.
The "A" dimension is based on a nominally gauged pipe
thread "make-up" of 0.600" (15mm) per ANSI 82.
1 [71/2 threads approximately]. 2.
All platings and paintings are decorative and intended
for interior use.
General Installation Instructions
Model F30R dry sprinklers must be installed only in
standard (ANSI B 16.3 class 150 and ANSI B 16.4 class
125) pipe tees even at branch line ends. They should not
be installed into elbows and pipe couplings located on
drop nipples to the sprinklers. For these and other fittings
including CPVC*, the dry sprinkler should be installed
into a fitting to conform to protrusion into the fitting in ac-
cordance with the diagrams. The "A" dimension of the dry
sprinkler, which extends into the freezers or a freezing
zone from wet pipe systems, should be selected to pro-
vide, as a minimum, the specified lengths in inches
shown in the following chart, between face of the fitting
and the outside wall or ceiling of the protected area. The
following chart is used for freezing zones when the ambi-
ent tem erature around the wet pipe system is kept at 40
OF / 4°C and specifies the minimum length for fitting face
to ceiling or wall (outside) for different protected area
temperatures.
Length (Face to Ceiling"all) ;Temperature (Protected Area)-
12 inches / 300 mm -20°F / -29°C
18 inches / 450 mm -40°F / -40°C
24 inches / 600 mm -60°F / -51 °C
j" For temperatures falling between those in the above chart, the
minimum length may be determined by interpolation: _
During installation, the following steps must be followed:
1. Cut the specified size hole (see illustrations) for the
sprinkler in the ceiling or wall directly in line with the
tee.
2. Apply pipe joint compound to the 1" (25mm) pipe
threads and install sprinkler using the Model G3 or
G3 R/C Sprinkler Wrench as specified.
3. Install the Model FP push -on / thread -off escutcheon or
CCP cover plate if required.
Note: Installation of the Model F30R Sprinklers is not rec-
ommended in copper pipe systems, as this may reduce
the life expectancy of the sprinklers.
Model F3QR Concealed and Recessed
Installation Instructions
The Model G3 R/C wrench (Fig. 1) is designed to locate
on the wrenching pads of the recessed sprinkler while
centering in the cup. A standard %2" drive ratchet may
be used to drive this wrench. Figures 1 and 2 show
sequentially the insertion of the wrench. First the wrench,
with its jaws above the sprinkler deflector, is moved
laterally until centered with the cup. Then raise the
wrench inside of the cup until its jaws engage the
sprinkler's square wrenching pads (Fig. 3). To remove
the wrench, follow this procedure in reverse order. Care
should be taken to avoid striking the deflector, with the
wrench.
5.
Model G3 Wrench (Fig. 4) is used for installation of
Pendent and Horizontal Sidewall sprinklers.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and
installation. REMOVE THIS PROTECTION AT THE TIME
THE SPRINKLER SYSTEM IS PLACED. IN SERVICE
FOR FIRE PROTECTION. Removal of the protectors
before this time may leave the bulb vulnerable to
damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE
PROTECTORS BY UNDOING THE CLASP BY HAND.
DO NOT USE TOOLS TO REMOVE THE
PROTECTORS.
Maintenance
The Model F3QR Quick Response Dry Sprinklers should
be inspected quarterly and the sprinkler system
maintained in accordance with NFPA 25. Do not remove
the factory applied thermally sensitive wax fillet between
the bulb supporting cup and the wrenching boss. Do not
replace this wax with a substitute substance. An Alternate
substance may interfere with proper operation of the
sprinkler. Do not clean sprinklers with soap and water,
ammonia or any other cleaning fluids. Remove dust by
using a soft brush or gently vacuuming. Remove any
sprinkler which has been painted (other than factory
applied) or damaged in any way. A stock of spare
sprinklers should be maintained to allow quick
replacement of damaged or operated sprinklers. Prior to
installation, sprinklers should be maintained in the original
cartons and packaging until used to minimize the potential
for damage to sprinklers that would cause improper
operation or non -operation.
Spears CPVC sprinkler adapter tees (with steel thread
insert) can only be used with horizontal sidewall
sprinklers which do not require protrusion into tees to
prevent ice or debris blockage of sprinkler inlets. These
CPVC tees do not permit sufficient sprinkler inlet
protrusion as required for pendent installation.
o .x
Fig. 1 - G3 R/C Wrench Fig. 2 - G3 R/C Wrench
Fig. 4 - G3 Wrench
Fig. 3 - G3 R/C Wrench
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual
Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified
and reputable sprinkler contractors located throughout the United States. Canada and foreign countries.
Manufactured b
The Reliable Automatic Sprinkler Co., Inc. Recycled
Hel 800) 431-1588 Sales Offices Paper
800) 848-6051 Sales Faxlabld914) 668-3470 Corporate Offices Revision lines indicate updated or new data
ww•r:.reliablesprinkler.com Internet Address E.G. Printed in USA 3/06 P/N9999970175
CITY OF SANFOAD )FIRE DEPARTMENT
FEES FOR SERVICES
PHONE # 407-302-2516 - FAX # 407-302-2526
p
DATE:
I
PERMIT #: ('J /
BUSINESS NAME / PROJECT:
ADDRESS:_A'2gS Z/ AI;01ai
PHONE NO.: _41 7 32-^foLy % FAX NO.:
CONST. INSP. [) C / O INSP.:[ j REINSPECTION [) PLANS REVIEW
F. A. (}. F.S. [ j HOOD ) PAINT BOOTH [ J BURN PE41,4
TENT PERMIT (} TANK PERMIT ( 1 OTHER [ J
TOTAL FEES; Sy (PER UNIT SEE BELOW) COMMENTS:
Fees
per Bldg. Unit Fees
rnust be paid to Sanford Building Department; 300 N. Park Ave., Sanford, Fl. M71 Phone # -407- 330-
5656. Proof of Payment must be made to Fire Prevention division before any further services can take place.
I certify that the above is true and correct and that will
comply with all applicable codes and ordinances of
the City of Sanford, Florida. Sanford
t Preventio ivision Applicant's Signature