HomeMy WebLinkAbout183 Walnut Crest Run - BR08-000058 (WINDOWS) DOCUMENTSQ
CITY OF SANFORb PERMIT APPLICATION
Application #: S(, Submittal Date: v'
i Job Address: )
G
Vahlot Cre, f ,uh + Value of Work: S , Q ` u
Parcel ID: ZZ' 1 I ' t Uf ^y (,UU u" (Z5Q Zoning:
j
Historic District:
Description of Work: AdaL Pu ` oddty# / 000 9A Square Footage:
Permit Type: Building f Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign
Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole
Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required)
Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines
Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential Commercial
Occupancy Type: Residential e Commercial Industrial Occupancy Use Group(s):
Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required
Property Owwner: / l l c h g a l f Re4ec c q lloy 6e V Contractor: C Q I ti i
Yd
Pfj COY 0`/ ` Address:
I 3 walho c e i Rb t) Address: 2-3w -wq t i We FL.
32-7)1 Ley wood FL 275 2 _
Phone:
I) I 3 2'rJ E-mail: Phone b 2ZState License Number: CI , J Z G% 7
Bonding
Company: Address:
Architect/
Engineer: Address:
Plan
Review Contact Person Mortgage
Lender: Address:
Phone:
Fax:
Phone:
Fax: E-mail: Application
is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance
of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. [ understand that a separate permit
must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR
CONDITIONERS, etc. OWNER'
S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction
and zoning. WARNING
TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE- THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE
OF COMMENCEMENT. NOTICE:
In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records oi' this
county, and there may be additional permits required from other governmental entities such as water management districts, s to agencies, or federal agencies. cceptance
of permit is ve ' cation that I will notify the owner of the property ofthe mnt o Lien Law, FS 13. Signat1ire
o Owner/Agent Date Sigril.Cure ofContractor/Agent Date itcc_
af er- tl k-ler I P
nt O er/A n 's Name P t Contractor/Agent's ame 0,
6 Datd
Signature of Notary -State of Flori a Date HANNE
RE C. ELVESTER Notary
Public - State of Florida Commission
Expires Aug 16, 2009 Commission #
DD 462522 Produced
ID - APPROVALS:
ZONING: •O
UT11L:
FD: p
X \ O1 SecialConditions: &ctnC Rev
07.07 Sarah
H Staphana commission
peCFt
l008 Contractor/Ag9erronalyVtovt Produced ID ENG:,
BAG:_ 9-
72"
MAX
UNIT
FiT
I1
68
MA
I SA
HT
C MAX( UNI I WIU I H
11_7/8" ACRYLIC I
LO
I
63 15/16"
ACRYLIC
DLOI I;;
7
Fl1/16"
44 1/4" ACRYLIC DLO
95" r
MAX =
SASH
HT
96': 190 114"
MAX ACRYLIC
UNIT DLO
HT
5200 OUTSIDE MOUNT
W/REMOVABLESCREEN
96" MAX UNIT WIDTH
52XO MULTIPANEL SLIDER
2P2T OR 2P3T
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS .................. A
ANCHOR SCHEDULE & NOTES . ................2
SECTION VIEWS(5200).....................................3
SECTION VIEWS(52X0).....................................4
B.O.M: S..............................................................5
EXTRUSIONS(5200)..........................................6
EXTRUSIONS(52XO)..........................................7
INSTALLATION DETAIL .... :......................... 8-10
78" MAX UNIT WIDTH ACRYLIC SLIDER WNDBREAKER" REQUIREMENT
3/4" MAX. PANEL I j'-- -- 38 3/4" MAX. PANEL
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TOWIDTH
34 7/8" ACRYLIC = --
WIDTH COMPLY WITH THE FLORIDA BUILDING CODE
DLO
g_
F .. .____....
MAX 87 15116"
UNIT ACRYLIC
HEIGHT DLO
92 1/8"
MAX
PANEL
HEIGHT
5200INSIDE MOUNT &
OUTSIDE MOUNT W/ SPLINE
GROOVE
48 1/8" MAX PANEL WIDTH
h
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINOOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM VNANDOW SYSTEMS. INC. IS PROHIBITED.
PERM# _ D S61
DATE;
2. GLAZING OPTIONS:
FULL PANEL ACRYLIC SHEET
SPLIT ACRYLIC SHEET WITH USE OF CENTERBAR
3. APPROVED CONFIGURATIONS:
X/X" ISM W/ SPLINE GROOVE
X/X" OSM W/ SPLINE GROOVE
X/X" OSM W/ REMOVABLE SCREEN
X/X" INTERIOR SGD FRAME MULTIPANEL
X/X" EXTERIOR SGD FRAME MULTIPANEL
X/X" W/ SCREEN INTERIOR SGD FRAME MULTIPANEL
X/X' W/ SCREEN EXTERIOR SGD FRAME MULTIPANEL
X/X/X/X INTERIOR SGD FRAME MULTIPANEL
X/X/X/X" EXTERIOR SGD FRAME MULTIPANEL
X/X/X/X' W/ SCREEN INTERIOR SGD FRAME MULTIPANEL
X/X/X/X" W/ SCREEN EXTERIOR SGD FRAME MULTIPANEL
4. WINDBREAKER REQUIREMENT:
VENTS TO BE REMOVED AT WINDS GREATER THAN 75 M.P.H.
AS PER SECTION 2002.3 OF THE FLORIDA BUILDING CODE.
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN
THE DESIGN OF THIS PRODUCT. SEE SHEETS 9-11 FOR ANCHOR DETAIL.
6. ALL FRAMES AND VENTS SCREWED TOGETHER
7. PREFERENCE TEST REPORT. CTLA-1162W
8. SERIES / MODEL DESIGNATIONS -
ISM/OSM - HS-5200
MULTIPANEL - HS-52XO
9. WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO
PROPERLY TRANSFER ALL LOADS TO STRUCTURE. BUCK OR FRAMING IS
RESPONSIBILITY OF ARCHITECT OR ENGINEER OF RECORD.
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION.
4a
Y
Oi9A
e
6" MAX
I _ - 18" MAX O.C. (TYP)
6" MAX
18" MAX O.C. (TYP)-
6
MAX I --SEE NOTE 3 6.,
MAX I
INSTALLATION
ANCHORS (TYP)
MAX O.C. -- -_--
TYP) 18"
MAX O.C. III (TYP)
ANCHOR LAYOUT -52001SM/OSM
1 HRU NAILING PIN (ALUM. POPCH ENCLOSjRE
SEE SHEEt 9)
ANCHOR LAYOUT -52001SM/OSM
THRLI NAILING FIN (WOOD)
SEE SHEET 9)
6"
MAX (T`
6" -
MAX (TYP)
18"
MAX O.C.
TYP)
INSTALLATION
ANCHORS (TYP)
ANCHOR LAYOUT - (FRAME)
THRU FRAME TYP)
SEE SHEET 10,
NOTES:
1- INSTALL ONE ANCHOR AT EACH LOCATION,
2. INTO CONCRETE/MASONRY OR WOOD: SHIM AS REO'D AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS. MAX.
ALLOWABLE SHIM STACK TO BE 114". USCSHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT.
3. INTO ALUMINUM: SHIM AS RED AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS, MAX. ALLOWABLE SHIM STACKTOBE1/8". USE SHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT.
4. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
5. 3/16" DIA. ELCO TAPCON (OR EQUIV.) MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/4" INTO
MASONRY THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY. A MINIMUM EDGE DISTANCE OF 2 1/2" SHALL BE ACHIEVED.
6. #10 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN, EMBEDMENT OF 1 1/2" INTO 2 BY WOOD BUCK.
7. #8 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/2" INTO 2 BY WOOD BUCK FOR FININSTALLATION.
8. SEAL CORNERS WITH SMALL JOINT SEAM SEALANT.
9. ALL INSTALLATION ANCHORS MUST BE MADE OF A CORROSION RESISTANT MATERIAL OR COATING.
10. #8 X 3/4" SHEET METAL SCREW ANCHORS MUST BE USED WITH FULL THREAD ENGAGEMENT INTO ALUMINUM ENCLOSURES.
11. AN APPROVED MEMBRANE OR MATERIAL SHALL BE PLACED BETWEEN ALL DISSIMILAR METALS TO CONTROL GALVANIC CORROSION.
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM VANDO'W SYSTEMS. INC. 15 PROHIBITED,
NOTE 2
INSTALLATION
ANCHORS (TYP)
EX'
TYPICAL VERTICAL SECTION
OSM JAMB
2
OSM SILL
EXTERIOR
TYPI CAL HORIZONTAL SECTION
31
OSM HEAD W/SPINE GROOVE
OSM JAMB W/SPINE GROOVE
OSM SILL W/ SPLINE GROOVE
ALTERNATE FRAME MEMBERS
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS. INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM VANDOW SYSTEMS, INC. IS PROHIBITED.
TYPICAL VERTICAL SECTION
r r3
2 TRACK HEAD
2,
52 i 2I
2 TRACK JAMB /
2 TRACK EXT. SILL 2 TRACK INT. SILL 3 TRACK INT. SILL
ALTERNATE FRAME MEMBERS
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING 13 THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM N/INDOW SYSTEMS. INC. IS PROHI9ITED.
TYPICAL VERTICAL SECTION
111 DRAWINGIS'HESOLEPROPERTYOFCUSTOM
WINDOWS YSTEMS. INC. ANY RE PR ODUC7'ION IN PART OR AS .A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROHIBITED,
5200 ISM / OSM B.O.M. 5200 MULTIPANEL B.O.M.
ItcmN Die 4' Descri lion
OUTERFRAME ASSEMBLY (TYP)
i
i
2.187
1.
ISM HEAD
ALUM 6063-T6
3.000 ................a
r2 ;
2.937
1._._..._...... _...._._....._....
ISM SILL
ALUM 6063-T6
2.625
OSM SILL
ALUM 6063-T6
3.000.
u
2.937
L -
OSM SILL
ALUM 6063-T6
2.
OSM HEAD W/SPINE GROOVE
ALUM 6063-T6
3.000 -
2.937 H
uyu
OSM SILL W/ SPLINE GROOVE
ALUM 6063-T6
3.000 _--- - —
3.000 - _ _.-_ 3.000
I
1.911 j 1.911 1.911 j....
1
1
ISM JAMB OSM JAMB OSM JAMB W/SPINE GROOVE
ALUM 6063-T6 ALUM 6063-T6 ALUM 6063-T6
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THF. SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WI'IOLE WITHOUT THE
YJP,.ITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. 13 PROHIBITED.
1.000
j 1.000 h-
2.250
1.121
LOCKSTILE INTERLOCK
ALUM 6063-T6 ALUM 6063-T6
VENT ASSEMBLY (TYP)
a
4 1.000 I--
1.000 r--
i_ 2.750 r8i
1.805
BOTTOM RAIL CENTERBAR
ALUM 6063-T6 - ALUM 6063-T6
1.000
I
1 .780 -....
2.000 825
L
1 _...__... GLAZEBEAD
TOP RAIL ALUM 6063-T6
ALUM 6063-T6
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
ACRYLIC HORIZ SLIDFRS I BAT I`' 1/31120081 7 OF 11
1 .0 00
2 TRACK HEAD
ALUM 6063-T6
3.997
1.500
2 TRACK EXT. SILL
ALUM 6063-T6
3)
r_
3,687
911
2TRACK JAMB ALUM
6063-T6 1.
0oo i....
r.T7 3
TRACK HEAD ALUM
5063-T6 jj
5.
683 1.
500 3
TRACK EXT. SILL ALUM
6063-T6 5.
371 911
3TRACKjAmB
ALUM
6063-T6 3.
874 (2) J.
65 2
TRACK INT. SILL ALUM
6063-T6 PROPRIETARY
AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW
SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN
PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. PANEL
ASSEMBLY (TYP) 5.
562 4
5 3
TRACK INT. SILL ALUM
6063-T6 1.
000 MULTIPANEL
INTERLOCK ALUM
6053-T6 r
SCREEN
ADAPTOR ALUM
6063-T6 ASTRAGAL
ALUM
6063-T6 1900
SW 44TH AVE. OCALA,
FLORIDA 34474 ACRYLIC
HORIZ. SLIDERS F""" " BAT 1/31/20081 8
OF I I
SCREEN ENCLOSURE
MEMBERS BY OTHERS
1/8" MAX SHIM
PERIMETER CAI
BY OTHERS
WINDOW FR
HEAD (ISM)
EXTERIOR
WINDOW FR,
SILL (ISM)
PERIMETER C,
BY OTHERS
1/8" MAX SHIM --
SCREEN ENCLOSURE --
MEMBERS BY OTHERS
A`,VERTICAL SECTION
7.; IIJSIDE M
81NSTALLATION
SCREW ANCHOR
CAULK BETWEEN WINDOW -
FLANGE & SCREEN
ENCLOSURE
IULK BETWEEN WINDOW
ANGE & SCREEN
ICLOSURE
8INSTALLATION
SCREW ANCHOR
INTERIOR
8 INSTALLATION
SCREW ANCHOR
K BETWEEN WINDOW
JGE & SCREEN
OSURE
INSIDE MOUNT
5200 FRAME
INTERIOR
1/8" MAX SHIM--1 1\..._. PERIMETER CAULK
BY OTHERS
Bl\_HORIZONTAL SECTION
INSIDE MOUNT (ALUM)
WINDOW FRAME
SILL (OSM)
8INSTALLATION
SCREW ANCHOR
SCREEN ENCLOSURE
MEMBERS BY OTHERS
1/8" MAXSHIM— r-
PERIMETER CAULK - —
BY OTHERS
EXTERIOR —
DE MOUNT I-' CAULK BETWEEN WINDOW
RAME FLANGE & SCREEN
8INSTALLATION ENCLOSURE
SCREW ANCHOR
C)HORIZONTAL SECTION
I\ 7 /OUTSIDE MOUNT (ALUM)
tIMETER CAULK
DTHERS
1/8" MAX SHIM
SCREEN ENCLOSURE
MEMBERS BY OTHERS
r (ALTERNATE MOUNTING OPTION
1, 7" OUTSIDE MOUNT (ALUM)
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED.
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
avv w n.
I:S DR.""t4 "Y -E.
RYL H R SLIDERS BAT 1/31/2008
I:iDEC SCALE: U.^:3. WO.'
5200152X0 NTS CWS-183
RE',.!F.TiER SHEET 9OF 11
2 BY BUCK --
BY OTHERS
1/8" MAX SHIM
I
I
PERIMETER C
BY OTHERS
WINDOW I
HEAD 0SN
EXTERIOR
WINDOW FRAME
SILL (ISM)
PERIMETER CAULK
BY OTHERS
1/8" MAX SHIM - 1
2 BY BUCK
BY OTHERS
8 INSTALLATION
SCREW ANCHOR
CAULK BETWEEN WINDOW-- .
FRAME AND BUCK
BY OTHERS INSIDE MOUNT 1/8" MAX SHIM
I 5200 FRAME
INTERIOR
ILK BETWEEN WINDOW
ME AND BUCK PERIMETER CAULK --
THERS
I"
I
BY OTHERS
8 INSTALLATION 2 BY BUCK
SCREW ANCHOR
I i BY OTHERS
2 BY BUCK I
BY OTHERS
PERIMETER CAULK EXTERIOR
BY OTHERS
1/8" MAX SHIM - L CAULK BETWEEN WIND
OUTSIDE MOUNT --- FRAME AND BUCK
5200FRAME BY OTHERS
E\HORIZONTAL SECTION 8 INSTALLATION
8 j INSIDE MOUNT (WOOD)
II
SCREW ANCHOR
G6) RIZONTAL SECTIONI\ g 1 OUTSIDE MOUNT (WOOD)
WINDOW FRAME ---
SILL (OSM)
PERIMETER CAULK
BY OTHERS
i
INTERIOR
8 INSTALLATION-----
SCREW ANCHOR 1/8" MAX SHIM
CAULK BETWEEN WINDOW '
FRAME AND BUCK
BY OTHERS -- 2 BY BUCK
BY OTHERS
CH LTERNATE MOUNTING OPTIONgIA. UTSIDE MOUNT (WOOD)
8 INSTALLATION
SCREW ANCHOR
CAULK BETWEEN WINDOW
FRAME AND BUCK
1900 SW 44TH AVE. BY OTHERS
OCALA, FLORIDA 34474
TITLE
E, \VERTICAL SECTION INSTALLATION DETAIL WOOD - 5200 ACRYLIC XX
INSIDEINSIDE PA -
I-S: 'Rr( 51 b, _ •;.(TE.
PROPRIETARYANO CONFIDENTIAL RYL H R Z L DER BAT 1/31/200E
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM <FJ^E' SCALt;, DN^J IJO.:
WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE 5200152XO NT$ CWS-18.
WRITTEN PERMISSION OF CUSTONI VANDOW SYSTEMS. INC. IS PROHIRITED. : ELV. LEI TER L'I.iEE 7; 1 O OF 11
CONCRETE/MASONRY CONCRETE/MASONRY--
BY OTHERS BY OTHERS
CAULK BETWEEN FRAME ANDMINEDGEDIST.) OPENING BY INSTALLER
I
r- INSTALLATION ANCHOR. D
EXTERIOR FINISH', 3/16" MASONRY ANCHOR
BY OTHERS --j 4 7116"--"-{
3 3/16"
1 114_'
a.mF
00 . o
4 La
MINEMBEDMENT)
o0 1 BY WOOD
BUCK BY OTHERS Id
PERIMETER CAULK --- -
BY OTHERS
I
DOORFRAME -/
HEAD
I
CAULK UNDER SCREW J
HEAD BY INSTALLER
EXTERIIOR
INTERIOR
1 114'
MIN. EMBEDMENT)
1/4" MAX SHIM
SEE NOTE 2 & 3 SHEET 3)
1/4" MAX SHIM
SEE NOTE 2 & 3 SHEET 3)
INTERIOR
11 /2"
MIN. EMBEDMENT)
I--- CONCRETE/MASONRY
J BY OTHERS
D
a
2 BY WOOD
BUCK BY OTHERS
D
V
CAULK BETWEEN
A/ FRAME AND OPENIN(
Al D BYINSTALLF_R
a
a-
k
CAULK UNDER SCREW
7 HEAD BY INSTALLER ---- INSTALLATION ANCHORLL Jd d #10 WOOD SCREW
DOOR FRAME pMIN. EDGE DIST.) G oo. -DOOR FRAME JAMB o 0
l oo JAMB j% °•o.• o G
oo°, BY OTHERS
CAULK
EXTERIOR °
oo
A• 4 CAULK UNDER SCREW / • °' o •oP°°°
HEAD BY INSTALLER oo • o -
EXTERIOR FINISH PERIMETER CAULK -- \•----- EXTERIOR FINISHBYOTHERSBYOTHERSBYOTHERS
JIHORIZONTAL SECTION 1 _I17 /R'\,HORIZONTAL SECTIONg. MULTIPANEL (1 BY BUCK) "" ••• 1-.-
PERIMETER CAULK
INSTALLATION ANCHOR, I BY OTHERS
3/16" MASONRY ANCHOR 1 -CAULK UNDER SCREW
HEAD BY INSTALLER
I
OORFRAME SILL
I
i aPERIMETER
CAULK ----1 \ II N BY
OTHERS SET SILL IN BED OF CONCRETE OR GF THE
ENTIRE LENGTH OF SILL TO n
e n N n N SUPPORT ALL ANCHORS BY INSTALLER. 1
1/4" D
D p IN. EMBEDMENT) CONCRETE/
MASONRY BY
OTHERS ` - T-`,
VERTICALSECTION 9,%
MULTIPAFlE! (EXTERIOR SILL) E`.
ALTERNATE SILL OPTION 7, -
MULTIPANEL (INTERIOR SILLI PROPRIETARY
AND CONFIDENTIAL THE
INFORMATION CONTAINED IN THIS DRAWING 13 THE SOLE PROPERTY.OF CUSTOM WINDOW
SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WMOLE WITHOUT THE WRITTEN
PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. 9/
MULTIPANEL R BY BUCK) PERIMETER
CAULK BY
OTHERS i
r1_
1/4" MIN
EMBEDMENT L
1900
SW 44TH AVE. OCALA,
FLORIDA 34474 1 /
3112008 CWS-182 11 OF 11
4 .
I
PLOD" PLAN
DESCRIPTION: (AS FURNISHED)
LOT 125, PRESERVE AT LAKE MONROE
AS RECORDED IN PLAT BOOK 62. PAGES 12-15 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA
IuPMAMC 1"AACUl A1)ONS it.OT ONLY1
LOT 125 CONTAINS 6662 SOUARF FEET t (LOT ONLY)
THIS STRUCTURE CONTAINS 2381 SQUARE FEET t
TOTAL CONCRETE 492 (YItTH1N LOT ONLY) SO. FT, t
TOTAL-§OQ 37159
PERCENT OF CMCRETE STRUCTURE TO LOT 43X
c .Aw rmiy.ts na- in r u %
LOT 125 UP TO CURB CONTAINS 7165 SQUARE FEET t
THIS STRUCTURE CONTAINS 23al SQUARE FEET t
014CRETE 810 SO. FT. t MICLU(MG (SICIEwALK/APRON)
JOTAL SOD 3974 SQ FT, t____
A-• 5'19'41 "
L=46.50'
R = 500.00'
CB=N05.24'06"E
C= 46. 48'
BUILDING SETBACKS
FRONT: 25'
REAR: 20'
SIDE: 5'
CORNER: if,
WREPARED FOR:
CENTEX HOMES
I, ELEVA,90NS SHOVIIN ARE PER LOT GRAOINO
PLANS PROVIDED BY THE CLIENT.
LIJ
1'
GRAPRC SCALE
su) 0 Is xP
0)
00 UNPLATTED
k
34.94' 28.55'
S00'00'24"E S09'06'41 "W
LOT 125
L TYPE A
e
DRAINAGE
CV i i O
Yr 1 1
I 1
rl 1
11 1
1
i T 1 2 ye iL0i1L6 NW
192e "
aEQ i t
1 7 qL. Q 1 1 2 4
L.LiIt
FINISHED FLOOR
n EL£vA910N-10 a pi
r
T
SJ'
04
K In
I6yam. 1
VN i
jj y.,. O K!
P 4•
1 z
21.3•
O
1
J`ra 1 p U1111r EASEMENT 1
e-a»4°21i .R1.;+•'T+'e'—w-..Ash$
L•
75,0
L-a•ar
j C9-NDa'wI9'ER.47S.OD'
c1a-No4Yn'4e'e it c.a.a r
C-ftaErN JfSOS• PT - PCRKIT-QFwAY
R-4Y5.W
Ce-N04 33"Da•E
C.aa.s1•
WALNUT CREST FAUN
s0' MWT••O-WAY
LEGEND
al I.aNc ST:tBACx LINEMtwIN
MINioM LOT WIDTH
POLAR ON BOUNDARY
CENTERLIK PCC POINT OF COMPOUND CURVATURE.
R004T OF WAY LINE POC POINT ON CURVE
FK PROPOSED ELEVATION
0*
PD
OFFICIAL RECORD
PLANNED 1T£VELOPUChT
f
PROP06E0 DRAHAM FLOW A DENOTES DELI4 ANODE
L DENOTES AK LENGD4
4 1 CONCRETE C.S. DENOES CNORD KAR°NG
N * l9URhiY7N0 6USWE:tS 8 /Alp PC
DENOTES POINT Of CUP ArVRE a ,
PI
DEN0IES POINT OF WTERSECnON
leaf If III If 11111111 it III :ll III II ill II 11111 ill II 111.1111111111
y
r
THIS INSTRUMENT PREPARED BY`.
Name` jLvc+ 11 i 1 Address:
j- W, v- I W v- StaWof
Florida y
SEAGNOLE
COUNTY FLORIDA'
S NATURAL CHOICE MARYANNE
MORSra, CLERK OF CIRCUIT COURT SEMINOLE
COUNTY BK
07073 pg 17821 Npg) CLERK'
S # 2008112809 RECORDED
10/06/2008 01:03:51 pM RECORDING
FEES 10.00 RECORDED
BY T Smith Jr,-
00o0 12 Permit
Number Parcel ID Number (PID) The
undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida
Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION
OF P OPERTY (Le g I desc iption of the p Qperty and stre t addre s if available) Irk . ,
i u l . 1°f .Z.'7/ CERTIFIED pRYANN
y vA IT
rolMnilRT COU
TY, FLORIDA GENERAL'
DESCRIPTION OF IMPROVEMENT {'L f) ' 'FNmomoFL OWNER
INFORMATION
Name and
address: CONTRACTOR Name
and
address. e i l I,) day A 4r) (,, t v
Persons
within
the State of Florida Designated by Owner upon whom notice or otherdocuments may be served as provided. by Section 713.
13(1)(b), Florida Statutes. Name and address:
In addition to
himself, Owner Designates of To receive a
copy of the Lienor's Notice as. Provided in Section 713.13(
1)(b), Florida Statutes. Expiration Date of
Notice of Commencement: The expiration date
is 1 year from date of recording unless a different date is specified. WARNING_ TO OWNER:
ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND
CAN RESULT IN YOUR PAYING TWICE FOR IMPROVMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT
MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE. THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA
COUNTY OF SEMINOLE O . NER IGNATURE
t,/T OWNERS PRINTED NAME NOTE: Per Florida
Statute 713.13(1) (g), owner must sign...... and no one. else may be permitted to sign in his or her stead." The foregoing instrument
was ackno ledged efore me this day of L' , 20 Who isersonall p
y knownto me I k Iaby
C-
iNameofperson
making statement —, % OR who has
produced identification type of identification produced VERIFICATION PURSUANT TO
SECTION 92.525, FLORIDA STATUTES. UNDER PENALTIES OF
PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS STATED IN IT ARE TRIBE TO
THE BEST OF MY F NOWLEDGE AND BELIEF. 9 /1 -7
1 J Il . "--) RE OF NATURAL
PERSON SIGNING ABOVE hANNELORE C.ELVESTE.
i Notary Pub
i
Slate of Florida Aug 16, 2009hAyCommissi , p452522J,• M Commission #
Nota
Signature B National NotaryAssn. Bonded Y''. i