HomeMy WebLinkAbout3101 W SR 46 - NO PERMIT # (1988) Central Baptist Church (ROOF DOCUMENTS)STRAN BUILDINGS
1513 REDDING DRIVE
LAGRANGE, GEORGIA 30240
UL CERTIFICAT.ION
TO WHOM IT MAY CONCERN: DATE: 06/27/68
RE: BUILDING DESCRIPTION: CS 100' wide x 100' lono x 26' hioh
LOCATION: Sanford, FL
CUSTOMER: Central Ba of i st Church
STRAN JOB NO.: 72426
This is to certify that the "Metal Roof Assembly" furnished for
above referenced building_ qualifies for an Underwriter's
Laboratory Class 90 wind uolift rating when constructed in
accordance with details described in UL Roof Deck Construction
Number 245. Skylites are excluded from this certification.
Yours truly,
STRAN BUILaINGS
erbert W. Williams, P. E.
4
TO WHOM IT MAY CONCERN:
STRAN BUILDINGS
1513 REDDING DRIVE
LAGRANGE, GEORGIA 30240
LETTER OFCERTIFICATION --
DATE: 06/27/88
This is to certify that the STRAN basic components as indicated on STRAN
erection drawings incorporated in the building described below have been
designed for the loads specified in accordance with good engineering
practice utilizing the following recognized standards where aoorooriate:
M. B. M. A. , A. I . S. C. , A. I . S. I . , A. W. S.. Additions and deletions of
individual parts, as well as, the non-standard use of the standard
components or parts are not covered by this certification and is the
responsibility of the local builder, (Any exceptions are noted below).
BUILDER'S NAME:
BUILDER'S ADDRESS:
BUILDER'S CUSTOMER:
BUILDER'S CUSTOMER'S ADDRESS:
TO BE ERECTED AT:
DESCRIPTION OF BUILDING:
DEAD LOAD:
LIVE LOAD TO ROOF:
LIVE LOAD TO FRAME:
WIND LOAD:
OTHER LOADS:
LOAD COMBINATIONS:
STRAN JOB OR QOUTE NUMBER:
NOTES:
Mark Metal Structures Inc.
Longwood, F`
Central Baptist Church
Sanford, FL
Sanford, FL
CS 100' wide x 100' long x 26' high
4 @ 25' Bays
7.21 psf (approx. )
20 psf
20 0sf
100 mph
3 psf Coll. Load included in DL
DL + LL, DL + WL
72426
STRAN BUILDINGS, MANUFACTURER
NAME ANa, T I TLE 1%
bert
W. Williams, P. E. Loads
applied to this building in accordance with Southern Building Cote -
Congress International, Inc. 1985 Edition. (SBCCI COMD1iance No. 8750)
Other Drovisions of the code are the responsibility of the Engineer
of Record. STRAN certifies the design. The Builder is rw4
Pons i b l e for erection.
STRAN BUILDINGS
1513 REDDING DRIVE
LAGRANGE, GEORGIA 30240
UL CERTIFICATION
TO WHOM IT MAY CONCERN:
RE: BUILDING DESCRIPTION:
LOCATION:
CUSTOMER:
STRAN JOB NO.:
DATE: 06/27/88
CS 100' wide x 125' lono x 26' hioh
Sanford, FL
Central Baptist Church
72372
This is to certify that the "Metal Roof Asserably" furnished for
above referenced building qualifies for an Underwriter's
Laboratory Class 90 wind uplift rating when constructed in
accordance with details described in UL Roof Deck Construction
Number 245. Skylites are excluded from this certification.
Yours truly,
4STRAN/
BUILDINGS
rt W. Williams, P. E.
STRAN BUILDINGS
1513 REDDING DRIVE
LAGRANGE, GEORGIA 30240
LETTER OF CERTIFICATION
TO WHOM IT MAY CONCERN: DATE: 06/27/88
This is to certify that the STRAN basic components as indicated on STRAN
erection drawings incorporated in the building described below have been
designed for the loads specified in accordance with good engineering
practice utilizing the following recognized standards where aDDrooriate:
M. B.M. A. , A. I . S. C. , A. I . S. I . , A. W. S.. Additions and deletions of
individual Darts, as well as, the non-standard use of the standard
components or parts are not covered by this certification and is the
responsibility of the local builder, (Any exceptions are noted below).
BUILDER'S NAME:
BUILDER'S ADDRESS:
BUILDER'S CUSTOMER:
BUILDER'S CUSTOMER'S ADDRESS:
TO BE ERECTED AT:
DESCRIPTION OF BUILDING:
DEAD LOAD:
LIVE LOAD TO ROOF:
LIVE LOAD TO FRAME:
WIND LOAD:
OTHER LOADS:
LOAD COMBINATIONS:
STRAN JOB OR QOUTE NUMBER:
NOTES:
Mark Metal Structures Inc.
Longwood, FL
Central Baptist Church
Sanford, FL
Sanford, FL
CS 100' wide x 125' long x 26' `sigh
5 @ 25' Bays
7.21 osf (approx.)
20 psf
20 psf
100 moh
3 Dsf Coll. Load included in DL
DL + LL, DL + WL
72372
STRAN BUILDINGS, MANUFACTURER
NAME
7 -------
W. Williams, P. E.
Loads applied to this building in accordance with Southern Building
Code - Congress International, Inc. 1965 Edition. (SBCCI Compliance No.
8750) Other provisions of the code are the resoonsibility of the
Enoineer of Record. STRAN certifies the dr-sigri. The Builder is
responsible for erection.
If