Loading...
HomeMy WebLinkAbout196 Towne Center Cir - BC04-000148 (FIRE SPRINKLER PLAN) DOCUMENTS (A)PERMIT ADDRESS CONTRACTOR ADDRESS 0(� T irl-�'i�`� PHONE NUMBER PROPERTY OWNER ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR — PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE FEE SUBDIVISION PERMIT # v r O DATE I k o (s �---` PERMIT DESCRIPTION Ire- PERMIT VALUATION G L (O d SQUARE FOOTAGE 0 W SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, FI. 32771 / P. O. Box 1788, Sanford, FI. 32772 (407302-2520 /FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: October 14, 2003 Business Address: 196 Towne Center Circle Oce. Ch. #34 New Mercantile Business Name: Factory Recreational Warehouse Ph. ( ) Contractor: Simplex Grinnell Ph. (407) 235-1100 Fax. (407)235-1150 Architect/Engineer: Ph. Reviewed [ J Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner Comment: Plans reviewed as Mercantile Occupancy. Class "B" per L.S.C. FD reserves right to require applicable code requirements if occupancy use changes. Sprinkler plans to be submitted for review, permitting, and inspections. Application —Existing Building Type IV 1.1 Fire Sprinkler Design: Wet Pipe Design criteria 1.2 Sales & Pre -Sales Areas: Ordinary Hazard group # 2 storage in height not to exceed 12' (ft) 1.3 Density for this area — 0.18 GPM/SQ FT 2500 sq ft, 250 p.s.i. for outside hose usage 1.4 Office Break Room: — Density -0.15 G.P.M./S. Q. FT 1.5 Operating area: 1, 500 sq. ft. Normal K factor W1155 degree heads chrome recess • Two hour hydro required • Provide fire sprinkler contractor at time of building finial • 48 hour notice on all fire inspections SYSTEM DEMAND @ BASE OF RI: 570.1 GPM @ 59.5# STORE FRON SCOPE OF WORK SIMPLEX GRINNELL TO BEGIN @ EXISTING 4" GROOVED CAP INSTALL NEW: ' 4" SCH 10 CENTERFEED CROSSMAIN W/ THREADED WELDED OUTLETS SCH 40 - B. LINES W/ CAST IRON BLACK FITTINGS TOP BEAM CLAMP HANGERS W/ 6-0 ALL THD ROD SPRINKLERS - QUICK RESPONSE 1/2" CHROME RECESS 155° SPRINKLERS - NO CENTERLINE TILE ALL DROPS 1 X 2-0 W/ 1 X 1/2 REDUCER ALL DIMENSION CENTER TO CENTER Steel I -Beam or Bar Joist Swivel Ring Model 300 Michigan Top Beam C -Clamp or Equal W / Lock Nut All Thread Rod 3/8 X 6-0 Pipe TYPICAL B. LINE HGR UN Top Beam C -Clamp IN LOCATION SUBJECT TO FREEZING CONDITIONS, IT IS THE OWNER'S RESPONSIBILITY TO SPRINKLERS PROVIDE HEAT THROUGHOUT WET PIPE SPKR SYSTEMS AREAS AND ENCLOSURE FOR DRY DESCRIPTION TYPE ORIFICE TEMP FINISH PIPE, DELUGE AND OTHER TYPE VALVES CONTROLLING WATER SUPPLIES TO SPRINKLE RSYSTEMS THIS DWG AND THE INFORMATION AND DESIGN APPLICATION HEREIN CONTAINED IS THE PROPERTY OF SIMPLEX GRINNELL LP AND/OR ITS SUBSIDARIES AND IS LOANED UPON TY -FRB QUICK RESPONSE PENDENT SPRINKLER 1/2 155 CHROI EXPRESS CONDITIONS THAT THE SAME BE RETURNED TO SGLP UPON REQUEST. ALL INFORMATION HEREIN CONTAINED SHALL BE TREATED AS SECRET, AND CONFIFENTIAL; NO REPRODUCTION OF THIS DWG OF ANY PART THEREOF SHALL BE MADE WITHOUT WRITTEN CONSENT OF SGLP. CANOPY I SYMBOL I QTY SPRINKLER PLAN VIEW 1/4:= 1'-0 SYSTEM'TYPE WET DRY DELUGE PREACTION XXX APPROVALS CITY OF SANFORD EDGARDO L, CORDOBA MECHANICAL ENGINEER, P.E. CERTIFICATE #57991 13649 TET,HERLINE TRAIL ORLANDO FLORIDA 32837 SIMPLEX GRINNELL TYCO FIRE AND SECURITY 3701 N. JOHN YOUNG PARKWAY ORLANDO FLORIDA 32804 TELEPHONE NO: 407-235-1100 FAX NO: 407-235-1150 NOTES TYPE SYSTEM,,- WET PIPE TYPE OCCUPANCY - ORDINARY HAZARD GP -2 DENSITY .18 GPM/SQ.FT FOR 2500 SQ. FT + 250 HOSE MAXIMUM SPRINKLER SPACING 120 SQ.FT TYPE CONSTRUCTION - ACOUSTICAL TILE CLGS GYPSUM WALL BOARD WALL W/ METAL STUDS DESIGN, MATERIAL AND INSTALLATION PER NFPA-13 1999 EXISTING PIPE NEW PIPE 0o HYDRAULIC CALC NODE POINT ALL DIMENSIONS CENTER TO CENTER CORRIDOR RECREATIONAL FACTORY SEMINOLE TOWN CENTER / 200 TOWN CTR CIRCLE SANFORD FLORIDA ADDITION TO EXISTING WET PIPE SYSTEM 7� �r..i a � f g r y � ,i s� r PIANS REVIEWED CITY OF SANFORD WATER FLOW TEST STATIC PRESSURE RESIDUAL PRESSURE GPM FLOWING CONDUCTED BY S/G AUG 2003 65# 55# 2420 n c .r 1 1� 7;;C DRAWN BY: RAF DATE: 10-7-03 SCALE: 1/4 = 1-0 DWG NO.: FP -1 I_. _ __... _ __..._