PERMIT DESCRIPTION
PERMIT VALUATION 1 0( 006
SQUARE FOOTAGE ct S
e
TO SYSTEM - ELEV. 17'-0!I'
6' ELECT. BELL
0
WATERFLOW SWITCH
GAUGE ASSEMBLY
: _ HYDRAULIC PLACARD
2' o
2' ANGLE VALVE
0'-4 �
HD CABINET
00 � 6 & WRENCH
(U
- ELEV. 2'-4
N I
4' I.B.R.
2' x 2'-0 W/ 45' U
Riser Detail
No Scale
-WET
1
:Inspectors Test Conn. Detail
No Scale
B.O.P. 20'-0 -
EXTERIOR WALL
x
NORTH
NOTE:
ALL DROPS TO BE
I'x24W/ V x V R.C,
Fire Sprinkler Piping Plan
TOTAL AREA 34,560 SQ FT.
12'
Building Section
No Scale
SCALE 3/32'=1'-0'
INC ATR
HANGER RING
S,I,N, R3615
S,I.N, TY6137
1/2"2(5.6K)
/4"1(114.OK
155' QR
200 SR
RELIABLE F1 FR
ai
TYCO EC -14
CHRM PEND
BRASS UPR
SEMI-REC
NO ESC
QUICK RESPONSE
STANDARD RESPONSE
STANDARD SPRAY
EXT, COVERAGE
ImZ�:r
Hanger Detail
>IDEWINDER
INC ATR
HANGER RING
No Scale
SEE SITE PLAN
FOR CONT,
-zo
;011 01
IL
r"
General Notes:
1. Design Criteria: Wet pipe system of automatic sprinklers hydraulically designed to
provide .20 gpm/sq ft throughout the warehouse area and .10 gpm/sq ft in the
office area. All sprinkler head spacing and locations to comply with NFPA 13, 1999
edition and the manufacturers specifications.
2. All roll grooved piping sizes 2" thru 4" to be Sch. 7 black steel, all threaded
piping 1" thru 1-1/4" to be Sch, 40 black steel. All fittings to be mechanical
roll grooved or cast iron threaded.
3. All material, devices and installation to comply with NFPA 13, 1999 edition, and
The City of Sanford.
4. All overhead piping to be hung with U.L. listed hangers properly spaced in
accordance with NFPA 13, 1999 edition.
5. All piping to be hydrostatically tested at 200 psi for (2) hours. All underground
piping to be flushed before any overhead piping is tied in.
6. All firewall penetrations to be sealed in accordance with their rating.
� 2f
0
00
"
a U 'Ln
�ZWr�
U 1 1 H
W¢��(y)
C:]��-Q�`°
a
_j co
W L,.., 0 -j (tJ I
c� co
J U L'- I CL I
LLQ(YQo�
Zf-<0't
E3ZZa 0
QW3wIt
W U 077
W oZE3x
G�LL_ MOT¢
LL_ O.-,JWL.-
�_Vx
n
Fire
Sprinkler
Piping Plan
CONTRACT # COMM,
DRAWN ; B,A.J.
CHECKED ; J.C.
DATE ; 10-19-04
TOTAL HEADS :156
SCALE ; AS NOTED
FP -2
SHEET 2 OF 2
ai
ai
z
ID
Z
P-
Q
¢
0
¢
H
W
Q
Zry
(]
0
�
¢
¢
J
Q
�-
V
Z
p
H
>
W
'-
W
�
3
W
Z
W
0
,CD
0
In
I-
Q
01
I
11D
I
1
I
Z
o
r,
0_1z
1
CONTRACT # COMM,
DRAWN ; B,A.J.
CHECKED ; J.C.
DATE ; 10-19-04
TOTAL HEADS :156
SCALE ; AS NOTED
FP -2
SHEET 2 OF 2
n
DOOR
SHEDULE
0
TYPE
a,"�`je :.«.
OCATION
A
3068
HOLLOW CORE WOOD
INTERIOR
B
3068
METAL
INTERIOR
C
3068
METAL
EXTERIOR
D
6070
STOREFRONT
GLASS
EXTERIOR
E
10'X
10' OVERHEAD
METAL
INTERIOR
F
14' X
14' OVERHEAD METAL
EXTERIOR
G
20'X
14' OVERHEAD
METAL
EXTERIOR
H
3068
METAL HALF-LIGHT
EXTERIOR
I
3068
METAL FULL -LIGHT
INTERIOR
n
PLANS REVIEWED
Cj-r'y OF SANFORD