Loading...
HomeMy WebLinkAbout112 French Ave - BC05-001908 (MCDONALDS) (INTERIOR REMODEL) (A)d d PERMIT ADDRESS \\ 'k� C� SUBDIVISION cn .,r CONTRACTOR_ �'� \ \� C:�ri� t�L� �- PERMIT # �� DATE ADDRESS �� (� �`iPERMIT DESCRIPTION PERMIT VALUATION PHONE NUMBER AQ") � SQUARE FOOTAGE PROPERTY OWNER �C-U ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR 0 PLUMBING CONTRACTOR d �3 tT1 MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMITT NUMBER FEE 0 TITLE. 5UILDING fP,,.,.,ENO 5 1 TE AID D fP,,,E5.5 112 F� VATIONa ENC#� AVENUE �5 T /3 1 T E e 13 013 INDEX OF DRAWING& ARCH I TCTIA AL . C5 COVER SHEET' r Al TOILET ROOM A2 SEATING PLAN y s ELECTRICAL I E1 ELECTRICAL PLAN 4 LIGHTING SCHEDULE I. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITIONS OF THE FLORIDA BUILDING CODE 2001, FLORIDA PLUMBING CODE 2001, FLORIDA MECHANICAL CODE 2001, THE FLORIDA ELECTRIC CODE 2001, FLORIDA ACCESSIBILITY CODE 2001 4 ALL OTHER APPLICABLE LOCAL, STATE, 4 FEDERAL CODES 4 ORDINANCES 4 ALL AUTHORITIES HAVING LOCAL JURISDICTION. 2, THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED FROM THE M05T COMPLETE INFORMATION AVAILABLE TO THE ARCHITECT. ALL DATA ON EXISTING CONSTRUCTION CONDITIONS ARE APPROXIMATE 4 SHALL BE VERIFIED PRIOR TO COMMENCING ANY WORK. 3. IT.SHALL BE THE SUBCONTRACTOR'S RESPONSIBILITY TO PERSONALLY FIELD INSPECT THE JOB SITE PRIOR TO SUBMITTING HIS BID. THE INSPECTION IS REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLYFAMILIAR W/ THE EXISTING CONDITIONS 4 THEIR INTERFACE W1 THE NEW CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. 4. THE SUBCONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE UJ/ THE LATEST EDITION OF THE GENERAL CONDITIONS OF THE CONTRACT, AIA DOCUMENT 4201."A`'COPY OF THIS DOCUMENT 15 AVAILABLE a THE CONTRACTORS OFFICE UPON REQUEST. 5. ANY ADJUSTMENT TO THE CONSTRUCTION CONTRACT;_;4DDITION5, DELETIONS OR CHANGE ORDERS, SHALL BE APPROVED 5Y THE OWNER, GENERAL CONTRACTOR, 4 ARCHITECT IN WRITING, ro. DURING THE CONSTRUCTION PHASE, THE ADMINISTRATION OF THE CONSTRUCTION CONTRACT SHALL BE PERFORMED BY THE MCDONALDS CONSTRUCTION MANAGER. 1. ALL WORK (EQUIPMENT, MATERIALS, 4 LABOR) SHALL HAVE A MINIMUM WRITTEN GUARANTEE FOR A PERIOD OF ONE (1) YEAR, UNLESS SPECIFIED OTHERWISE, FROM THE DATE OF SUBSTANTIAL COMPLETION AGAINST ANY DEFECTS IN SAID WORK, U1/ APPROPRIATE REPAIR OR REPLACEMENT e NO ADDITIONAL COST TO THE OWNER. S. ALL MATERIALS 4 EQUIPMENT SHALL BE INSTALLED IN A NEAT 4 FIRST CLASS WORKMANLIKE MANNER. THE ARCHITECT RESERVES THE RIGHT TO DIRECT THE REMOVAL 4 REPLACEMENT OF ANY ITEM, IN HIS OPINION, THAT DOES NOT PRESENT AN ORDERLY 4 5REASONABLY NEAT- OR WORK-IANLIKt c— 'I II APPEARANCE. THE REMOVAL 4 REPLACEMENT SHALL BEy'DONE_ WHEN DIRECTED BY THE GENERAL 00, ANF C-00;�4fRED L t E 5 1 D E CONTRACTOR, 4 W/OUT ADDITION L G05fiT"C9"=TI=Ile"OUINER. 1711 U North Him MAR 0 7 f. ® ® ® • 0 ® ® ® ® 0 • • 40 ® ® 0 ® ® ® • ! ® ® ® • es Avenue, Tampa, Florida 336.eom07, Ph 813/353-0035 Fax 813/353-4350 Website: www.hartleypurdy.com p • Y Date; 9. THE CONTRACTOR SHALL COMPLY W1 THE MANUFACTURER'S INSTRUCTIONS 4 RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS, 10, CONTRACTOR SHALL MAINTAIN ORDERLY HOUSEKEEPING DURING THE PROCESS OF CONSTRUCTION 4 UPON COMPLETION SHALL THROUGHLY CLEAN ALL AREAS. FINAL CLEAN UP SHALL INCLUDE THE FOI_! WING: i A. SWEEPING- FLOORING, B. DUSTING REMOVAL OF DIRT, PAINT DRIPPINGS, OIL, GREASE, 4 OTHER BLEMISHES FROM ALL SURFACES, INCLUDING PIPING 4 EQUIPMENT. C. WINDOWS, GLA55 LIGHTS, 4 MIRRORS SHALL BE WASHED 4 CLEANED. D. PAINT OVERRUNS 4 PUTTY SMEARS SHALL BE REMOVED. E. HARDWARE SHALL BE CLEANED 4 POLISHED W1 FLANNEL CLOTH. 11. WORK TO BE DONE CONSISTS OF FURNISHING ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, 4 ALL ITEMS 4 SERVICES REQUIRED FOR CONSTRUCTION IN CONFORMITY W1 GENERAL NOTES 4 PLANS. 12, THE PLANS SHOW THE LOCATION OF ALL FIXTURES 4 EQUIPMENT 4 ARE INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE 4 LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL EVERY 4 ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORK. 13, THE SUBCONTRACTORS SHALL REMOVE ALL CONSTRUCTION RUBBISH, SCAFFOLDING, EQUIPMENT, TEMPORARY PROTECTION, TEMPORARY FIELD STRUCTURES, 4 OTHER COMPONENTS WHICH WERE REQUIRED IN CONNECTION W1 THE CONSTRUCTION, BUT NOT A PERMANENT PART THEREOF. 14. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS 4 INSPECTIONS REQUIRED FOR THE wORK 4 PAY ALL CHARGES INCIDENTAL THERETO, 15, PROVIDE DOOR HARDWARE IN CONFORMANCE W1 ADA REQUIREMENTS. �� �/`� 16. THE SUBCONTRACTOR SHALL FURNISH ALL MISCELLANEOUS FACILITIES AS NEEDED, INCLUDING TEMPORARY 5TAIR5, TEMPORARY RAMPS, LADDERS, RUNWAY5, STAGING, SHORING, 5<;AFFOLDING, BRIDGES, RAILING, BRACING, BARRIERS, CLOSURES, PLATFORMS, TEMPORARY PARTITIONS, WASTE ® ® ® CHUTES, 4 SIMILAR ITEMS. 11. THE SUBCONTRACTOR SHALL PROTECT ALL CONSTRUCTION COMPONENTS DURING THE: COURSE OF PAINTING 4 SHALL PROMPTLY CLEAN ALL RESIDUE, SPLATTER OR OVERSPRAY UPON COMPLETION OF ® ® ® H15 WORK. THE CONTRACTOR SHALL USE DROP CLOTHS, MASKING, 4 OTHER SHIELDING DEVICES TO THE GREATEST EXTENT PRACTICAL TO PROTECT ALL ITEMS NOT TO BE PAINTED OR THOSE ITEMS WHic,H HAVE ALREADY RECIEVED FINAL FINISH COATS. a ALL PAINTING: REQUIRED FOR THIS PROJECT SHALL BE PERFORMED IN ACCORDANCE w/ THE MANUFACTURER'S SPECS FOR PRODUCT HANDLING, SURFACE PREPARATION, PAINTING APPLICATION, CURING/DRYING TIME BETWEEN COATS, CLEANING 4 PROTECTION OF PAINTED SURFACES UNTIL THE SOURCE OF CONSTRUCTION IS COMPLETE. PAINT COLORS TO BE SELECTED FOR THESE DOCUMENTS ARE AS MANUFACTURERD BY BY GLIDDEN DIVISION OF 5CM CORP., ALTERNATE ACCEPTABLE MFR ARE AS FOLLOWS- BENJAMIN MOORE, D.P.I., RU5TOLEUM, PRATT LAMBERT, SHERWIN-WILL IAM5. 19. ALL DRYWALL PARTITIONS ARE DIMENSIONED CENTERLINE TO CENTERLINE UNLESS OTHERW15E NOTED, ALL MASONRY PARTITIONS ARE DIMENSIONED OUT TO OUT, Y 20. ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC., LOCATED IN RATED PARTITIONS SHALL BE BACKED W1 DRYWALL AS REQUIRED TO MAINTAIN RATING. CONTRACTOR TO VERIFY WALL THICKNESSES REQUIRED FOR ALL ELECTRICAL PANELS, FIRE EXTINGUISHER PANELS, ETC. 21, PROVIDE DOUBLE STUDS 4 BLOCKING WHERE REQUIRED TO SUPPORT MISCELLANEOUS ITEMS, I.E., TYPICAL CASEWORK, CA5INET5, GRAB BARS, ETC. CONTRACTOR SHALL FURNISH 4 INSTALL ALL BACK-UP SUPPORTS. 22. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE OWNER'5 REPRE5ENATIVE BEFORE CONTINUING W/ CONST, 0,4023& 23, CONTRACTOR SHALL VERIFY ALL DIMENSIONS 4 COORDINATE ALL TRADES. 24. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS 4 DIMENSIONS OF EQUIPMENT. 25. REVIEW ALL ELECTRICAL LOCATIONS W1 OWNER BEFORE SIGN OFF FOR DRYWALL. �j //��, 2G. ALL THRESHOLDS 4 FLOOR FINISH CHANGES TO BE PLACED UNDER CENTERLINE OF DOOR UNLESS OTHERWISE NOTED. ' 21. COORDINATE TELEPHONE 4 SECURITY W1 OWNER BEFORE PROCEEDING, SCOTT J. PURDY AR 91676 :ari�r�li�f Y. u WATERCLO5ET FLUSH CONTROL GRAB BAR W/ BACK-UP TO BE LOCATED ON THE SUPPORTS WIDE SIDE OF HANDICAP STALL VERIFY FIXTURE JUMBO TISSUE DISPENSER WITH BACK-UP SUPPORTS mI I 3'-O° x 4'-8" i ( t- GRAB BAR W/ 42" MIN, 12" - 36" MIN. BACK-UP SUPPORTS x l I I �'( I `r 0 o ELECTRIC HA 12 01 I / I y x ° o HAND DRYER 4--------1---I I I 5'{0" DIA. --------5 0 U / I 1 I — � — N �- \ 60 x 6m I O I — ----- t I 2'-0" z y x u } I F®� I //I HANDICAPPED SIGN X C z 24 MIN. C.L. AFF. X m cp cn 0 1B — — — — I I m 10� r i m I — I O`.:JI m X I I IQ I IA IA -' 1 I p I- - - -48" x 48" - _ 3 -ml x �I-8N REQ'D U Q u - 14l 1/2 1 D 48 x 48 I 3 -f0 x -0,Al _ I I I CORIAN L - - - - —I I- - I m I 5ACKSPLA5H -- 22" N BACK-UP SUPPORT 811 1 3/4" SOLID CORE DOOR a - - - - (SEE NOTE 01-4) MIN. 18 HANDICAPPED SIGN PLATE GLA55 MIRROR I ® i 1'-3'� I \\� 5'-0' C.L. AFF. CENTERED OVER LAV. 00x6o I V { 21-011� I m -�- ----- I N.M. DOORFRAME 4 I I I 5'-0" DIA. � ---- -- ! I -- r---- r m it K� L — — — 1 I I �l _ J 2x4 FRAMING O — o ALL LAVATORIES MUST NAYS 0 OPEN 5 X 1 i ix m �/ o o U U A COMBINATION FAUCET z CORIAN VANITY TOP U 0 �S CAPABLE OF SUPPLYING m 0 I WARM WATER FOR A MIN. - SEE FINISH SCHEDULEt @ � r 3'-0" x 4'-8" 7 I i 5 ~ C OF 10 5ECONDS. � �' FOR WALL FINISH m -' all,} Z TYP. PARTITION TYPE T: z INSULATE NOT WATER PIPING L SEE SHEET Al COVED QUARRY TILE BASE UNDER VANITIES V W ctl L NOTE: ADA CLEARANCE LINE. PIPES UNDER �° PIPES 4 SINK BOWL SHALL � VANITIES TO BE MAX. NOT PROJECT BEYOND I L VA T BOXED OR WRAPPED TH15 LINE. ENLA ED TOILET FLAN MOUNTING Ill4I HT5 5ECTION LAVATOR"r 4 DETAIL 545E Al v2" = r-oll Al I" = 1'-o Al TOILET 9QQM NOTES: 1. N/A. 2 , 2. ALL DIMENSIONS SHOWN ARE TAKEN FINISH TO FINISH I \ > \ WALL L3. SOAP DISPENSER FURNISHED d INSTALLED BY OWNER I % ` J 4. PROVIDE 1/2' PLYWOOD BOTH SIDES OF WALLS TO TOP { I I I o I TIE INTO EXISTING OF DOOR JAMB5. PROVIDE GYP BD. W/ WALLPAPER OR I I i'WROUGiW-ROOT°'' 2" 1/2' PLYWOOD W/ TILE ABOVE JAMB TO V ABOVE CEILING I I I I- � J __ VENT 5TAC� coR PLANS FOR (U NLESS DE EXISTING WALL sNEPI CLE4\N ---- 5. SEE FLOOR PLAN FOR LOCATION OF GYP. BD.I I I OUB' I _j NEW WALL 6• TYP _ - L 4 2-4 I �-. 1. RESTROOM ENTRY DOORS SHALL CONFORM TO THE � I I i � I , I I� O' 3' VENT 2 � I 2' 2 LAV EXISTING TO BE REMOVED FOLLOWING: DOOR CLOSERS SHALL BE ADJUSTED SO / ' ` \ _ THAT THE SWEEP PERIOD FROM AN OPEN POSITION OF I I \lj I / T) 10 DEG. WILL TAKE AT LEAST 3 SECONDS TO MOVE TO LL_ , / 2 A POINT 3 INCHES FROM THE LATCH MEASURED TO THE LEADING EDGE OF THE DOOR C I 2" \ I W`I, 2' S. INSULATE NOT WATER PIPES AND DRAIN PIPES TYPICAL 9, MOUNT H.C. SIGN V-0- AFF to CENTER OF SIGN I>< FLOOI URINAL 10, ALL NEW TOILET ROOM 4 STALL DOORS TO HAVE DRAIN 4` FACBC 2001 COMPLIANT HARDWARE. 2' ` 3' 11, TOILET ROOM DOORS DO NOT NAVE LATCHES I I 2' 12, GC TO REQUEST 8 FOLLOW ADA REPORT WHEN ✓Lf f N FLAN AVAILABLE 'CLITION LAV I � FLOOR DRAIN 2- 4' Al 1/4" = I'-0"1/4 2' I 'y I 3® I TOILET i20OM 5ACK-Uig 5UPFORT6 WC NOTE: ALL BACK-UP SUPPORTS SHALL BE CUT BETWEEN STUDS TOILET AGGE5SOFlE5 SGNEDULE4` LAV SO THAT FACE OF SUPPORT 15 FLUSH W/ WALL STUD. ITEM MODEL • SUPPLIER Wc 4' (1) 2x6'5 4'-0" LONG CENTER MTD a 33' A.F.F. IA GRAB BAR 812-001-42 UNIVERSAL MFG. 4I 1A TO CENTER OF SUPPORT (GRAB BARS) SOO-821-1414 21 SANITARY lU (1) 2x6'S 3'-6" LONG CENTER MTD 33° A.F.F. IB GRAB BAR 0`12-001-360`12-001-36-36 CONNECT W AS1'E_ EXISTING I N iB TO CENTER OF SUPPORT (GRAB 5AR5) TOILET TISSUE SCOTT JUMBO PER5ECO ELECTRICAL LEGEND O(2) 2x6'5 2'-6' LONG (1) MOUNTED a 44" A.F.F. 2 DISPENSER JRT 108-515-4400 (l) Q 53" A.F.F. TO CENTER OF SUPPORT (HANDICAPPED STALL T155UE DISPENSER) 3 BABY CHANGING TABLE_ KOALA CORP. 2x4 FLUORESCENT ILET 3 (1) 2x62'-0" LONG MOUNTED 50 THAT TOP O 800-666-0363 FIXTURET 0""ROOM %� j� � '�° %� DIAGRAM O OF CHANGING SUFACE IS MAX 34' A.F.F. fel � I i A't fRY I 5ER (BABY CHANGING TABLE) HAND DRYER (COLORS UNIVERSAL MFG, 1x4 FLUORESCENT l OTHER THAN WHITE #RA -5 800-821-1414 FIXTURE Al FITS 4 (1) 2x10 I'-4" LONG MOUNTED a 48' A.F.F. TO AT ADDITIONAL COST) EMERGENCY CENTER OF SUPPORT (ELEC. NAND DRYERS) UNIVERSAL MFG, NOTE: CONTRACTOR TO VERIFY AS -BUILT CONDITIONS DO NOT CONFLICT WITH PROPOSED O ANGLE FRAME MIRROR 24'x36" 800-821-1414 LIGHTING DIAGRAM. O (2) 2x6 2'-6" LONG (1) MOUNTED a 10" A.F.F. ^ COUNTER MOUNTED UNIVERSAL MFG. NOTE: CONTRACTOR TO VERIFY PLUMBING REQUIREMENTS WITH PROPOSED DIAGRAM. AND (U a MOUNTED 3f0" A.F.F. TO CENTER OF < )6 SOAP DISPENSER 6304-68 500-521-1414 NOTE: SAWCUT EXISTING FLOOR TO RELOCATE SERVICE TO NEW WATER CLOSETS, URINALS, SUPPORT (URINAL) (6" SPOUT) AND LAVATORIES. DOWEL SLAB PATCH TO EXISTING SLAB PROVIDE NEW CERAMIC TILE TO <s> (1) 2x6 WALL TO WALL 3'-1' MTD a 30" A.F.F. TOWEL DISPENSER 8-2621 BOBRICK TO CENTER OF SUPPORT (LAYS) (OPTIONAL) 609-151-290(0 REFLECTED f I j� I FLAN MATCH EXISTING. 2 L I � L NOTE: EXTEND NEW HACW LINES AS REQ, FROM NEAREST SUPPLY SOURCE TO NEW FIXTURES. SOAP DISPENSER UNIVERSAL MFG, NOTE: PROVIDE TRAP PRIMERS FOR TOILET ROOM FLOOR DRAINS. (OPTIONAL) 6542 80x0-821-1414 Al I/4° = I'-0" AR 91876 No. 0402.86 TCTLE: TOILET ROOM 112 FRENCH AVE. SANFORD, FLORIDA ST/SITE# 009-1303 I$2U 12.15.04 SHEET NO Al A.-0003276 OP .I+PUROHT � UYARCfHTECTURE� INC. ALLL RIGHRIOHT3RE9ERVED 2001 o 4- • • m U M • e • 0000 w �n • • oMo O I 13 • • M cn Lm 00 a 0 ® ® M M o • ® H • o • o • • AR 91876 No. 0402.86 TCTLE: TOILET ROOM 112 FRENCH AVE. SANFORD, FLORIDA ST/SITE# 009-1303 I$2U 12.15.04 SHEET NO Al A.-0003276 OP .I+PUROHT � UYARCfHTECTURE� INC. ALLL RIGHRIOHT3RE9ERVED 2001 a J—P 1/141 %1 V1 121 .I. � 4. c6 scarr J. PURFUY AR 91876 No. 0402.86 TrrLE: SEATING PLAN `112 FRENCH AVE. SANFORD, FLORIDA Sr/SrrE# 009-1303 [EXATE 12,15.04 A�' --0003276 IOPYRIGHT i?TLBY+PURDYARCH1TRM)PA INC. A & f -RIGHTS RESERVED 3001 ell 'A • • • LM CL• + • • • JL • 121 .I. � 4. c6 scarr J. PURFUY AR 91876 No. 0402.86 TrrLE: SEATING PLAN `112 FRENCH AVE. SANFORD, FLORIDA Sr/SrrE# 009-1303 [EXATE 12,15.04 A�' --0003276 IOPYRIGHT i?TLBY+PURDYARCH1TRM)PA INC. A & f -RIGHTS RESERVED 3001 ELECTRICAL PLAN SCALE: 1/4"=V-0" /04273 LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURES CAT. NO. VOLTAGE LAMPS MOUNTING 2x4, 4 -LAMP FLUORESCENT SEE PLIGHTING FIXTURE SCHEDULE NOTE NO. 1 • (4) F32T8 CEILING RECESSED FLANGE FIXTURE W/PRISMATIC 120 4100'K ACRYLIC LENS • b 1x4, 2 -LAMP FLUORESCENT SEE LIGHTING FIXTURE SCHEDULE NOTE NO. 1 (2) F32T8 CEILING RECESSED FLANGE FIXTURE W/PRISMATIC 120 4100'K U • J ACRYLIC LENS 3 W • • 4— COMPACT FLUORESCENT LITHONIA NO. AF2/18DTT6AR-GES r (1) 18W CEILING RECESSED oB DOWNLIGHT WITH CLEAR • U 120 DTT cn ALZAK REFLECTOR w 4100'K FLUORESCENT CAN SECURITY LIGHTING SYSTEMS ® (2) CEILING RECESSED 0 8" DIAMETER NO, D4226E120/BLACK 120 26W • DTT M cd 31"H x 20"W PENDANT ACCESS LIGHTING NO. 22006—RU (4) CEILING PENDANT (� �Y E" 120 16"W X 36"H WALL SCONCE ACCESS LIGHTING NO. 22009—RU (1) WALL SURFACE 120 60W VERIFY M.H. WITH • • INTERIOR DESIGNER • EMERGENCY BATTERY PACK LITHONIA NO. ELM -2 WITH WALL SURFACE OR 120 UNIT (VERIFY HEIGHT LITHONIA NO, 6ELM-2P WHEN CONNECTED TO W/ARCHITECT) REMOTE HEAD EXIT SIGN WITH BATTERY SEE LIGHTING FIXTURE NOTE NO, 2 WITH CEILING SURFACE BACK—UP AND EMERGENCY 120 UNIT LIGHTING HEADS LIGHTING FIXTURE SCHEDULE NOTES: 1. FLUORESCENT LIGHT FIXTURE PERFORMANCE SPECIFICATION: ELECTRICAL CONTRACTOR MAY SELECT LIGHT FIXTURES MEETING THE FOLLOWING REQUIRMENTS: A. SHEET METAL SHALL BE MINIMUM 22 GAGE STEEL. WHITE ENAMEL PAINTED. B. LAY—IN FIXTURES SHALL HAVE HINGED, GASKETED DROP DOWN DOOR FRAMES. C. BALLASTS SHALL BE: MAGNETEK: 8432112OL/8232112OL/83321120L OR ADVANCE: REL-4P32—RH—TP/REL-2P32—RH—TP/ REL-3P32—RH—TP 2. ORDER LED EXIT SIGNS WITH LETTER COLORS THAT COMPLY WITH LOCAL CODES FROM SECURITY LIGHTING. FOR RED LETTERS USE #PRB (UNIVERSAL) FOR GREEN LETTERS USE #PGB (UNIVERSAL) DIRECTIONAL ARROWS AS REQUIRED BY THE LOCAL AUTHORITIES. OR IF THE ABOVE EXIT SIGNS DO NOT COMPLY WITH LOCAL CODES USE: LED SIGN WITH BATTERY BACKUP, LETTER SIZE, COLOR, TYPE AND CONSTRUCTION. GENERAL NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. 2• CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED. 3. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, LICENSES, UTILITY COORDINATION, AND INSPECTIONS AS REQUIRED BY THE CITY OR UTILITY COMPANY. CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT REQUIRED BY UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. 4. CONTRACTOR SHALL LEGIBLY MARK—UP A SET OF 24"x36" DRAWINGS TO REFLECT AS—BUILT CONDITIONS, AND TURN OVER TO ARCHITECT. WIRE/RACEWAY: 1. ALL CONDUCTORS SHALL BE COPPER, CONDUCTOR INSULATION SHALL BE DUAL TYPE THHN/THWN 75°C. (1677) FOR DRY, DAMP, AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING THHN 90-C (1947) MAY BE USED FOR DRY LOCATIONS ONLY, ALL CONDUCTORS SHALL BE COLOR CODED AS REQUIRED BY NEC AND FU THER IDENTIFIED AND CODED AS SPECIFIED HEREINAFTER. COLOR CODING SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, COLORED BRAID OR JACKET OVER THE INSULATION OR BY MEANS OF SUITABLE COLORED, PERMANENT, NON—AGING, INSULATING TAPE APPLIED TO CONDUCTORS AT EACH CABINET OR JUNCTION POINT. 'THE C066R CODING SHALL BE ACCOMPLISHED AS THE CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL BE STRICTLY ADHERED TO: A) GROUND LEADS: GREEN B) 9.20/208 VOLT UNGROUNDED PHASE WIRES: PHASE A: BLACK PHASE 8: RED PHASE C: BLUE NEUTRAL: WHITE THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED THROUGHOUT. 3. UNLESS OTHERWISE INDICATED, ALL BRANCH CIRCUIT CONDUCTORS SHALL BE NO. 12 AWG. ANY BRANCH CIRCUIT RUN OVER 75 FEET IN LENGTH, MEASURING ONE WAY FROM THE FIRST OUTLET OF THE CIRCUIT TO THE PANEL, SHALL BE NO. 10 AWG. FOR THE ENTIRE CIRCUIT. 4. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT AND THIN WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC TUBING. COUPLINGS AND CONNECTORS SHALL BE STEEL SET—SCREW TYPE, ZINC OR CADMIUM PLATED. MC CABLE MAY BE USED WHERE CONCEALED IN WALLS. 5. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED, AND SUPPORTED BYIMECHANICAL TYPE `CADDY' CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. 6. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT GROUND CONDUCTOR. GROUND CONDUCTOR SHALL BE INSTALLED IN ENTIRE RACEWAY SYSTEM INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. EQUIPMENT GROUND CONDUCTOR SIZES FOR CIRCUITS WITH PHASE CONDUCTORS LARGER THAN NO. 12 AWG ARE INDICATED ON DRAWINGS. GROUND CONDUCTORS SHALL BE CONNECTED TO GROUND BUSS IN PANELBOARDS. 7.. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. GENERAL NOTES: ;ROUNDING: 1. CONNECT EXIT, NIGHT LIGHTS AND EMERGENCY LIGHTING FIXTURES TO 1. THE INTERIOR ELECTRICAL SYSTEMS SHALL BE COMPLETELY AND UNSWITCHED LEG OF EXISTING EMERGENCY/EXIT LIGHTING CIRCUIT. EFFECTIVELY GROUNDED AS REQUIRED BY NATIONAL ELECTRICAL CODE. ALL METALLIC RACEWAYS SHALL BE MECHANICALLY AND ELECTRICALLY 2. 'NL' DENOTES FIXTURE UNSWITCHED FOR USE AS NIGHT LIGHT. SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, FITTINGS AND EQUIPMENT. OUTLET BOXES/DEVICES: DRAWING NOTES: 1. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES (1 CONNECT TO EXISTING 20 AMP, 120 VOLT DINING ROOM LIGHTING CIRCUIT. IN BOXES SHALL BE PLUGGED WITH SUITABLE BLANKING DEVICE. O CONNECT TO EXISTING 20 AMP, 120 VOLT TOILET LIGHTING CIRCUIT. 2• OUTLET BOXES SHALL BE 4 INCH SQUARE x 2-1/8" DEEP. OUTLET BOXES LOCATED ABOVE THE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS O 2 NO. 12 AND 1 NO. 12 E.G. — 1/2"c WITH JUNCTION BOX AND CONNECTION OF BLACK PERMANENT MARKER. TO NEW HAND DRYER. CONNECT TO EXISTING 120 VOLT, 20 AMP HAND DRYER CIRCUIT. SWITCHGEAR: PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CURRENT INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. LIGHTING FIXTURES: 1. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING FIXTURES LISTED IN THE FIXTURE SCHEDULE, 2. THE CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL THE FIXTURES TO THE ARCHITECT. THESE CUTS SHALL BE SUBMITTED IMMEDIATELY AFTER THE CONTRACTOR HAS RECEIVED AN APPROVED MATERIAL LIST FROM THE ARCHITECT. 3. BALLASTS FOR FLUORESCENT LAMPS SHALL BE ENERGY SAVING ELECTRONIC. LOAD SUMMARY 4. ALL FIXTURES SHALL BE PROPERLY AND CAREFULLY SUPPORTED NO ADDITIONAL LOAD ADDED. AND ALIGNED, AND THE CONTRACTOR SHALL FURNISH AND INSTALL LOADS ADDED ARE OFFSET BY ALL NECESSARY STEEL SHAPES, ETC., FOR SUPPORT OF FIXTURES LOADS REMOVED BY DEMOLITION. AS REQUIRED AND DETAILED ON THE DRAWINGS. PROVIDE JUNCTION BOX STEM MOUNTED FROM DECK TO SUPPORT ALL CEILING MOUNTED EXIT LIGHTS. 5. LIGHTING FIXTURES SHALL BE CLEAN AND LAMPED WITH NEW LAMPS AT THE TIME OF FINAL INSPECTION. r _ DIAMONDBACK ENGINEERING, Inc® 3502 Henderson Blvd., Suite 203 Tampa, Florida 33609 'fele. (813) 350-0080 Fax, (813) 350-0083 REG. NO, EB9758 • • 0 ° • U • • o • • Q) • b U • s 3 W • • 4— ® r • M • U • cn w m 0 M ® ® • M M r., • . M cd • E" • • • MICHAEL WOMACK P.E. 49040 No. 04273 TITLE: 112 FRENCH AVE. SANFORD, FLORIDA ST/SITE# 009-1303 DATE IUE 12.17.04 1- BEET NO AA -0003276 Q)COPYlaaw 11.,IRTLEY+PURDI'ARCHITE0I'UIiE, INC. ALL RIC&TS RESERVED 2001