Loading...
HomeMy WebLinkAbout1401 W Seminole Blvd - BC03-001104 (CFRH) (MODULAR BLDG) DOCUMENTS6 PERMIT ADDRESS PHONE NUMBER PROPERTY OWNER ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR P(I=,n c MECHANICAL CONTRACTOR PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE t7 SUBDIVISION PERMIT # " ` OBI DATE PERMIT DESCRIPTION C, PERMIT VALUATION SQUARE FOOTAGE d y y CITY OF SANFORD PERMT APPLICATION a erg • o. Permit No.: Date: Job Address: 14401 Q Cbk-. 5e y%i d l e. *91 V Permit Type:. _ Building Electrical Mechanical Plumbing Fire Alarm/Sprinkler Description. of Work: rnnd,ge+ b%..lckin '-to Ike "ack -%er- 5 . "V-tL 66v- ca4 : Additional Information for Electrical & Plumbing Permits Electrical: Addition/Alteration _Change of Service Temporary Pole [New AMP Service (# of AMPS im Plumbing/ Residential: Addition/Alteration New Construction (One Closet Plus Additional) Plumbing/ Commercial: Number of Fixtures Number of Water & Sewer Drainage Lines Number of Gas Lines Occupancy Type: _Residential Commercial _ Industrial Total Sq Ftg: Value of Work: S Type' of Construction: Flood Zone: Number of Stories:_ Number of Dwelling Units: Parcel Igo.: ., 1 `, D S fl G 1.17 0 000 (Attach Proof of Ownership & Legal Description) Owner/ Address/Phone:-+pn4tnaA Flora A _1kP_r4t0A^J 1401 63. Se uv i Ndip- r"31v32.77`71 &40 `I - 3a.1 - C1500 Contractor/ Address/Phone: ir, t. i N e r/ State License Number: Contact Person: r t 44rr%t S Phone & Fax Number: +. Q 1- 303-3 _ Vol oo Title Holder (If other than Owner): Address: Bonding Company: Address: Mortgage Lender: Address: Architect/ Engineer Phone No.: Address: Fax No.: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or iristallation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. . NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that maybe found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. : w Acceptance of permit is verification that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. V. RX9,"C 01 3 3 ignature of er/Agent to Signature of Contractor/Agent Date Rodney. R.Smith Pr, it Owner/Agent's N e V/ 00P 3 3 Oekof-Kotai - tate of Florida e y+ N Este L. Orseno Y ` MY Commission DD069642 o, wP Expires January 23 2006 Owner/ Agent is x Produced ID _ Personally Known to Me or APPLICATION APPROVED BY: S 6s. -b I — Print Contractor/Agent's Name Signature of Notary -State of Florida Date Contractor/ Agent is Personally Known to Me. or Produced ID Date:- 3 Special Conditions: 0 I Centra'l Florida REGIONAL HOSPITAL 0 Carl Harris 1401 West Seminole Blvd. Director, Plant Operations Sanford, Florida 32771 407-321-450QA2j&1& la,: 407-302-7300 carl.harris@hcahealthcare.com centralfloridaregional.com 4t,7 - 50;L - -7 310 Ap a CITY OF SANFORD FIRE DEPARTMENT FEES FOR SERVICES HONE # 407-302-1091 * FAX #: 407-330-5677 DATE: Z PE #: 3- CBUSINESSNAME /PROJECT: 1 __ _ _ •. a PHONE NC 3a Ir `4,5 AX NO.:[t 7 CONST. INSP. I ] C / O INSA REINSPECTION [ ] PLANS REVIEW [ ] F. A. [ ] F.S. [ ] I [ ] PAINT BOOTH [ ] I1BUJ N PERMIT - TENT[ J PERMIT ] NK PERMIT [ ] OTHER Wtedu LA ro, TOTAL FEES: S (PER UNIT SEE BELOW) , COMMENTS: Address /Address / Blde. # / Unit ## / Unit # Sauare Footage Fees per Bldg. / Unit 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ll. 12. 13. 14. 15. 16. 17. 18. 19. 20. Fees must be paid to Sanford Building Department, 300 N. Park Ave., Sanford, FI. 32771 Phone # -407- 330-5656. Proof of Payment must be made to Fire Prevention division before any further services can take place. I certify that the above is true and correct and that I will comply with all applicable codes and ordinances of the City of ord, Florida. c San ord Fire Prevention ision pIicant' Signature 77 r.. . a; Y d3 IM CITY OF`S'ANFOTt©L MIGAlf PER, UI1T rAPPL1C O, f Permit Number.` `I Date: / ?J1'O.".,) , The undersigned hereby applies for a permit to install.the following electrical: Owner's Name: ,een Pkorrca, c t r\ O{ii o`.` u - r C Address of Job: qo l3¢ ,-'ew, O P j V . rO Electrical Contractor: a81Y Residential: Non -Residential: Ii-0 i By Signing this application I am stating that I am in compliance with City of Sanford Electrical Code. 1 Applicant's nature L 000 State License Number CITY OF SANFORD BUILDING DIVISION OWNER/BUILDER AFFIDAVIT CONSTRUCTION CONTRACTING Owners of property when acting as their own contractor and providing direct, onsite supervision themselves of all work not performed by licensed contractors, when building or improving farm outbuildings or one -family or two-family residences on such property for the occupancy or use of such owners and not offered for sale or lease, or building or improving commercial buildings, at a cost not to exceed $25,000, on such property for the occupancy or use of such owners and not offered for sale or lease. In an action brought under this part, proof of sale or lease, or offering for sale or lease, of any such structure by the owner -builder within 1 year after completion of same creates a presumption that the construction was undertaken for purposes of sale or lease. This subsection does not exempt any person who is employed by or has a contract with such owner and who acts in the capacity of a contractor. The owner may not delegate the owner's responsibility to directly supervise all work to any other person unless that person is registered or certified under this part and the work being performed is within the scope of that person's license. For the purposes of this subsection, the term "owners of property" includes the owner of a mobile home situated on a leased lot. To qualify for exemption under this subsection, an owner must personally appear and sign the building permit application. State law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct, onsite supervision of the construction yourself. You may build or improve a one -family or two-family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or occupancy. It may not be built or substantially improved for sale or leitse. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. I, Rodney R. Smith , do hereby state that I am qualified and capable of performing the requested construction involved with the permit application filed. I will assume full responsibility as an Owner/Builder Contractor, and will personally supervise all work allowed by law on the permitted structure. U.', _,zx 0( (d 3 OwnerB er Signature Date Rodney R. Smith Print Owner/Builder Name 1 3I>03 tgnature of Notary —State of Florida Date Owner is x Personally Known to Me or has Produced ID Esta L. Orseno My commission DD088842 o n Expires January 23 2005 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SEMINOLE COUNTY, FL (691500) Short Desc: SOUTHEAST Project: 1578-3719F Owner: SOUTHEAST Address: UNKNOWN UNKNOWN City: SANFORD State: FL - Zip: 0 Type: Warehouse (storage) Class: New Finished building PermitNo: 0-- Storeys: 1 GrossArea: 840 Net Area: 840 Max Tonnage: 3 (if different, write in) Compliance Summary Component Design Criteria Result Gross Energy Use 63.64 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 1 0 COMPLIANCE CERTIFICATION: I hereby certify that the plans and specifications covered by.this calculation are in compliance with the Florida Energy Efficiency Code. A PREPARED DATE: ` • o— O.3 I hereby certify that this, building is in compliance with the Florida Energy EfficioncpCode. 41 't' w OWNER AGENT. DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908, F.S. a" Plan No._._.. Approved ey CLAYTON E. BARROWS BUILDING OFFIC DATE: 7!2! tipdulm WIding Plans Evan~ Plorlda Lloom No. SMP-1 If required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Code. REGISTRATION p rnce No. WILLIAM J. McCANN so 2$Z /FL ELECTRICAL SYSTEM DESIGNER LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 N 6-15-1996 A;55PM FROM zM CEHIIFIED COPY MARYANNE MORSE NOTICE OF COUNJENCEMENT CLERK OF CIRCUIT f oURTECOU , i. Permit No. Tax Folio No. SE ORIDq State of Florida County of Seminole DEPUTY rLFRK FEB 14 200 The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance vintF Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Description of property: (legal description of the property and street address if available) description 3. Owner information a. Name and address e- 1 iInterestinpropertyoft., •ritL. _ c. Name and address of fee simple titleholder (if other than Owner) Contractor 8. Name and address 1h er uDnw -&AQA. @yA . MAC- b. - Phone number was?, 4-2.1 Zel (. _ Fax number '357.. 5. Surety IIIIINIIIARIA10NpI11Al1AlAA111111D A1111A11 a. Name and address I Av.ANNiWRGE, MERN QF GIRSUIT MU" b. Phone number Fax n18t E cm Nry c. Amount of bond BK 04708 PS 1969 6. Lender CLERK'S # 2003027239 a. Name and address RECORDED W/14/a'003.0EONQ 81 NMRDrW S L 90 b. Phone number FgxndpWAM BY L Winley 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes: a. Name and address b. Phone number Fax number 8. in addition to himself or herself, Owner designates "O' rt S of c l=mg- „I q01 W - Se*%# nrAc Mud to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. a. Phone number Fax number aioZ - 30a,- -12 OW 9. Expiration date of notice of commencement (the expiration date is I year from the date of recording unless a differena date is specified) , L Lie- - - Signature of Owner Sw to (or affirmed) and subscribed before me this %day of 20 C7-=4 , by Personally Known OR Produced Identification 1hIl5 iN;TRt1MLr T Ki FARCD li r: Type of Identification Produced NAME Oar-( ADDIL 14n\ 1,x s} Este L. Orseno S ature of Notary Public, State of Florida a My Commission DD089842 ;cu ( Commission Expires: a' a,, Expires January 23 2D06 SANFORD FIRE DEPARTMENT ' FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 F.. D Plans Review Sheet Date: October 1, 2002 Business Address: 1401 West Seminole Blvd. Occ. Ch. #18-New Health care/Storage Business Name: Central Florida Regional Hospital Ph. (407) 321-4500 ext. 5720 Contractor: CR.J. Griffin & Company Ph. (407) 228-4645 Fax. (615) 344-2710 Reviewed [ ] Reviewed with comment [ X ] Rejected [ ] Reviewed by: Timothy Robles, Fire Protection Inspector/Plans Examiner -FL Comment: Fire department views this as File Storage Modular building for Health Care occupancy (FFP.C. 2000) Please read and respond back in writing to the yellow highlighted comments. Application — 900 sq. ft modular building, Type IV construction Egress - Two separate EXITS Address- Post address per comments on plans Fire Extinguisher- Mount one(]) 3A40BC fire extinguisher 36 "from floor, by front EXIT Final inspection required by Sanford Fire Department 1 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings Jurisdiction: SANFORD, SENENOLE COUNTY, FL (691500) Short Desc: SOUTHEAST Project: 1578-3719F Owner: SOUTHEAST Address: UNKNOWN UNKNOWN City: SANFORD State: FL- PermitNo: 0-- Zip: 0 Storeys: 1 Type: Warehouse (storage) GrossArea: 840 Class: New Finished building Net Area: 840 Max Tonnage: 3 (if different, write in) Compliance Summary Component Degign Criteria Result Gross Energy Use 63.64 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE: An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 1 /16/2003 EnergyGauge FlaCom FLCCSB v1.22 1 COMPLIANCE CERTIFICATION: I hereby certify -that tHe'-Ipians and specifications covered by_,this calculation are in compliance with the Florida Energy Efficiency Lode. ' PREPARED,.BT.1 / DATE: I hereby certify that thllis,building is in compliance with the Florida Energy Efficiency Code. Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553,908, F.S. Dale Plan No.__ approved By CLAYTON E. BARROWS BUILDING OFFIC DATE: Modular Building Plarn Examiner Plodit LWm No. SW-1 OWNER AGENT - DATE: If required by Florida law, I hereby certify (') that the system design is in REGISTRATIONcompliancewiththeFloridaEnergyCode. n rnCC No. WILLIAM J. McCANN So 252 bF ELECTRICAL SYSTEM DESIGNER LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 1/16/2003 EnergyGauge FlaCum FLCCSB v1.22 2 Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY, FL (691500) WEA File: Oriando.TMY) Whole Building Compliance Design Reference Total 63.64 100.00 ELECTRICITY 63.64 100.00 AREA LIGHTS 11.31 12.53 MISC EQUIPMT 1.21 1.21 SPACE COOL 12.12 17.37 SPACE HEAT 8.69 20.40 VENT FANS 30.30 48.48 Credits & Penalties (if any): Modified Points: = 63.64 PASSES Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY, FL (691500) WEA File: Orlando.TMY) Other Envelope Requirements Item Zone Description Design Limit Meet Req. ROOF 1578-3719F Exterior Roof - Max Uo Limit 0.04 0.09 Yes Meets Other Envelope Requirements 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY, FL (691500) WEA File: Orlando.TMY) External Lighting Compliance Description Category Allowance Area or Length ELPA CLP W/Unit) or No. of Units (W) (W) Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 24.0 600 60 Ext Light 2 Exit (with or without Canopy) 25.00 24.0 600 60 Design: 120 (W) r PASSES Allowance: 1200 (W) Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY, FL (691500) WEA File: Orlando.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ante STORAGE ROO 46 Storage & Warehouse - Fine 840 1 2 2 PASSES Active Storage PASSES Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY, FL (691500) WEA File: Orlando.TMY) System Report Compliance 15783719F System 1 Packaged Terminal Systems No. of Units 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System PTAC > 15000 Btu/h 10.00 7.60 PASSES Cooling Mode) Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.50 0.80 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PASSES 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 Plant Compliance Description Installed Size Design Min Design Min No Eff Eff IPLV IPLV Category Comp liance None Water Heater Compliance Description Type Category Design Eff Min Design Max Comp Eff Loss Loss Hance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] F] .SF.F] None 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 Project: SOUTHEAST Title: 1578-3719F Type: Warehouse (storage) Location: SANFORD, SEMINOLE COUNTY Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met d ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner ©p Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it N Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 6 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Proiect Information Project Name: SOUTHEAST Orientation: North Project Title: 1578-3719F Building Type: Warehouse (storage) Address: UNKNOWN Building Classificatio New Finished building UNKNOWN State: FL- No.of Storeys: I Zip: 0 GrossArea: 840 Owner: SOUTHEAST Zones No Acronym Description Type Load Profile Area Multiplier Total Area Isf] Isf] 1 1578-3719F Zone 1 CONDITIONED Uses Building Load 839.9 1 839.9 Profile 11 1/16/2003 EnergyGauge FlaCom FLCCSII v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume IN [ft] ft] plier sf] cf] In Zone: 1578-3719F 1 STORAGE R --- Storage & Warehouse - Fine 36.00 23.33 8.00 1 839.9 6719.0 Active Storage Lighting No Type Power Control Type No.of W] Ctrl pts In Zone: 1578-3719F In Space: STORAGE ROOM 1 Suspended Fluorescent 760.00 Manual On/Off 2 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value ft] ft] plier [sf] Btuthr. sf. F] Capacity lb/cf] [h.sf.FBtu] Btu/sf.F] In Zone: 1578-3719F 1 --- 0.5"SHEATH'G, 36.00 8.00 1 288.0 North 0.1077 1.4414 17.72 9.28 2x4xl6" oc, RIIBatt, 0.5 in. gyp 2 --- 0.5"SHEATH'G, 36.00 8.00 1 288.0 South 0.1077 1.4414 17.72 9.28 2x4xl6" oc, RIIBatt, 0.5 in. gyp 3 --- 0.5"SHEATH'G, 23.33 8.00 1 186.6 East 0.1077 1.4414 17.72 9.28 2x4xl6" oc, RIIBatt, 0.5 in. gyp 4 --- 0.5"SHEATH'G, 23.33 8.00 1 186.6 West 0.1077 1.4414 17.72 9.28 2x4xl6" oc, RIIBatt, 0.5 in. gyp 1/16/2003 EnergyGauge FlaCom FI,CCSB v1.22 Windows No Description Type Shaded UCen SC Btu/hr sf F] Vis.Tr W ft] H (Effec) Multi Total Area ft] plier [sf] In Zone: In Wall El Doors No Description Type Shaded? Width H (Effec) Multi it] [ft] plier Area Cond. Dens. Heat Cap. sf] [Btu/hr. sr. F] [lb/cf] [Btu/sf. F] R-Value h.sf.F/Btu] In Zone: 1578-3719F In Wall: EAST 1 --- In Wall: 'VEST 1 --- GLASS DOOR Polystyrene core 18 ga steel) 1 No 3.00 6.67 No 3.00 6.67 1 1 20.0 20.0 0.2919 37.00 2.41. 0.4982 0.00 0.00 3.43 2.01 Roofs No Description Type Width H (Effec) Multi ft] [ft] plier Area sf] Tilt Cond. Heat Cap Dens. deg] [Btuthr. Sf. F] [Btu/sf. F] [lb/cf] R-Value h.sf.F/Btu] In Zone: 1578-3719F 1 --- 2X4 TRUSS@24" O.C. 23.33 36.00 1 839.9 0.00 0.0393 5.06 21.69 25.44 Skylights No Description Type UCen Shading Vis.Tran Btu/hr sf F] Coeff W ft] H (Effec) Multiplier Area ft] [Sf] Total Area Sf] 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 In Zone: In Roof. Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: 1578-3719F 1 --- 2X6 FLOOR 27.33 70.00 1 1913.1 0.0569 6.34 29.33 17.58 Systems 15783719F System 1 Packaged Terminal Systems No. Of Units 1 Component Category Capacity Efficiency IPLV 1 2 3 4 Cooling System (PTAC > 15000 Btu/b (Cooling Mode)) Heating System (Electric Furnace) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) Air Distribution System (ADS System) 36000.00 34100.00 1005.00 10.00 1.00 0.50 6.00 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit Cap.Unit I/P Rt. Efficlenc Loss 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 Ext-Lighting Description Categories. Area/Len/No. of units sf/ft/Nol Wattage W] 1 Ext Light 1 2 Ext Light 2 Exit (with or without Canopy) Exit (with or without Canopy) 24.00 24.00 60.00 60.00 Piping No Type Operating Insulation Temperature Conductivity F] [ Btu-in/h.sf.F] Nomonal pipe Diameter in] Insulation Is Runout? Thickness in] Fenestration Used Name Glass Type No. of Glass SC VLT Frame Frame Panes Conductance Conductance Absorptance Btu/h.sf.F] [Btu/h.sf.F] Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHea Mat No Acronym Description Used [h.sf.F/Btu] ft] Btu/h.ft.F] lb/cf] t 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 264 Mat1264 ALUMINUM, 1/16 IN No 0.0002 0.0050 26.0000 480.00 0.1000 11 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 1-1/41N, 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 5 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 BOARD,1/2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 41N 178 Mad178 CARPET W/RUBBER PAD Yes 1.2300 265 Mad265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 0 HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 72 Mat172 AIR LAYER, 3/41N OR Yes 0.9000 LESS, VERT. WALLS 267 Mad267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 266 Mat1266 2x4@ 16" oc + RI i Batt No 8.3343 0.2917 0.0350 9.70 0.2000 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 2IN, 105 Mad 105 CONC BLK HW, 81N, No 1.1002 0.6667 0.6060 69.00 0.2000 HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/2IN No 1.8939 0.1250 0.0660 32.00 0.3300 86 Matl86 BRICK, COMMON, 4IN No 0.8012 0.3333 0.4160 120.00 0.2000 269 Matl269 75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 211 Matl2ll POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 N, 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 IN, 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 271 Matl271 2x4@24" oc + RI I Batt No 10.4179 0.2917 0.0280 7.11 0,2000 272 Mat1272 Panel with 7/16" panels Yes 0.9044 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 274 Mat1274 Solid core flush (1.375") Yes 1.7141 275 Mat1275 Panel with 7/16" panels Yes 1.0019 1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 6 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 279 Mat1279 Solid core flush (2.25") Yes 2.8537 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 281 Mat1281 Paper Honeycomb core Yes 0.9357 282 Mat1282 Solid Urethane foam core Yes 1.6500 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 steel) 1 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 81 Mat181 ASPHALT -ROOFING, Yes 0.1500 ROLL 244 Mat1244 PLYWOOD, WIN No 0.6318 0.0417 0.0660 34.00 0.2900 185 Matl185 CLAY TILE, PAVER, 3/8IN No 0.0301 0.0313 1.0410 120.00 0.2000 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 SIDING 11 Mad11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 47 Matl47 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 0 HW-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 SLAG1/2IN 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 3/81N 1001 ApLbMat1001 25"HARDI -PANEL No 0.3500 0.0210 0.0600 34.00 0.2900 1002 ApLbMat1002 2XTRUSS@24" No 5.0000 0.3300 0.0660 43.00 0.2900 0 1003 ApLbMat1003 2X8 @ 24" O.C. No 7.5758 0.5000 0.0660 43.00 0.2900 0 1004 ApLbMat1004 GLASS Yes 1.0400 1005 ApLbMat1005 2X6 STUDS @ 16" O.C. No 7.5758 0.5000 0.0660 43.00 0.2900 1/16/2003 EnergyGauge f IaCom FLCCSB v1.22 7 Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu] 1009 0.5"SHEATH'G, 2x4x16" oc, R1IBatt, 0.5 No No 0.11 1.44 17.72 9.2843 in. gyp Layer Material Material Thickness Framing No. ft] Factor 1 266 2x4 @ 16" oc + RI l Batt 0.2917 0.10 2 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 3 272 Panel with 7/16" panels 0.0360 0.00 4 1001 25"HARDI -PANEL 0.0210 0.00 Simple Massless Conductance Heat Capacity Density RValue No Name Construct_ Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h:sf.F/Btu] 1033 Polystyrene core (18 ga steel) 1 No Yes 0.50 2.0071 Layer Material Material Thickness Framing No. ft] Factor 1 284 Polystyrene core (18 ga steel) 1 0.00 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] h.sf.F/Btu] 1048 2X4 TRUSS@24" O.C. No No 0.04 5.06 21.69 25.4351 Layer Material Material Thickness Framing No. ft] Factor 1 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 2 23 6 in. Insulation 0.5000 0.00 3 1002 2XTRUSS@24" 0.3300 0.06 0 1/16/2003 EnergyGauge FlaCom FLCCSB v1.22 No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sf.F] [Btu/sf.F] Density lb/cf] RValue h.sf.F/Btu] 1050 GLASS DOOR No No 0.29 2.41 37.00 3.4257 Layer Material Material Thickness Framing No. ft] Factor 1 18 2 in. Wood 0.1670 0.00 2 1004 GLASS 0•00 Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] Btu/sf.F] lb/cf] [h.sf.F/Btu] No No 0.06 6.34 29.33 17.5758 1054 2X6 FLOOR Material Material Thickness FramingLayer No. ft] Factor 1 1005 2X6 STUDS @ 16" O.C. 0•5000 0.00 2 12 3 in. Insulation 0.2500 0.00 1/16/2003 EnergyGauge FlaCom FLccSB v1.22 9 HEAT LOSS AND GAIN ANALYSIS MANUFACTURER: SOUTHEAST MODULAR DESTINATION: FLORIDA VARIABLES TEMPERATURES(DEGREE F.) OUTSIDE SUMMER DB INSIDE SUMMER DB OUTSIDE WINTER DB INSIDE WINTER DB DESIGN GRAINS AT 50% RH DAILY RANGE(DEGREE F.) PAGE 1 OF,2 , PLAN NO. 1578-3719 MFR'S ID. SMM #10014 A/B OCCUPANT CONTENT OS := 94 OUTSIDE AIR CFM/OCCUPANT IS := 75 LIGHTING WATTAGE OW := 32 INCANDESCENT IW := 68 FLOURESCENT DG := 49 DO NOT INCLUDE DR := 19 BALLAST LOAD) OC 9 OA 20 IL 0 FL 800 GLASS AREA(SF) GROSS WALL AREA(SF) U-VALUES NORTH N := 0 NW := 187 UG := 1.04 GLASS EAST E := 0 EW := 288 UW := 0.09 WALL SOUTH S := 0 SW := 187 WEST W := 0 WW := 288 WOOD/METAL DOOR AREA WD := 40 WU := 0.46 DOOR GLASS/FRENCH DOOR AREA GD := 0 GU := 1.10 DOOR ROOF AREA R- := 840 RU := 0.05 ROOF FLOOR AREA F := 840 FU := 0.09 FLOOR GLASS SHADING FACTOR SF := 1.0 EQUIPMENT LOAD(BTUH/SF) EL := 15 HEAT GAINS (COOLING LOADS) SENSIBLE HEAT GAINS: A. SOLAR RADIATION THROUGH GLASS: NORTH SRN : = N• 30 • SF EAST SRE : = E• 44 • SF SOUTH SRS : = S • 5 6 • SF WEST SRW : = W• 158 • SF TOTAL SR := SRN + SRE SRS + SRW SR = 0 B. TRANSMISSION GAINS: 1. GLASS: GA :=N+E+S W GA= 0 TG : = GA• UG• OS IS) TG = 0 2. DOORS: TWG := WD•WU•(OS IS) TWG = 350 TGD : = GD • GU• OS IS) TGD = 0 3. WALLS: FIND EQUIVALENT TEMPERATURE DIFFERENCE ETD) TEMPERATURE CORRECTION: TC := OS - IS 20 DAILY RANGE CORRECTION: DRC := 0.5•(20 DR) ETD := TC + DRC ETD = 1 PAGE 2 OF, 2 NORTH TWN : NW - N) • UW • ( ETD + 15 ) EAST TWE : EW - E) • UW • ( ETD + 3 6 ) SOUTH TWS :_ SW - S) •UW• (ETD + 23) WEST TWW :_ WW - W)•UW•(ETD + 17) TOTAL TW := TWN + TWE + TWS + TWW TW = 1971 4. ROOF: TR := R• RU• OS - IS) TR = 798 5. FLOOR: FR : F• FU• 0 - IS) FR = 1436 TOTAL TRANSMISSIOM GAIN T := TG + TWG + TGD TW TR + FR T = 4555 C. OCCUPANTS: SO OC•230 SO = 2070 D. LIGHTS: L IL• 3.4) FL• 4.1) L 3280 E. VENTILATION: SV OC• OA• (OS - IS) • 1.1 SV 3762 F. DUCTS: SD := (SR + T + SO + L + SV)•0.05 SD 683 G. EQUIPMENT: EQ EL•F EQ 12600 TOTAL SENSIBLE HEAT GAIN SHG := SR + T + SO L + SV + SD + EQ SHG 26950 LATENT HEAT GAINS: A. OCCUPANTS: LO := OC•190 LO 1710 B. VENTILATION: LV := OC• OA• DG• 0.68 LV 5998 TOTAL LATENT HEAT GAIN LHG := LO + LV LHG 7708 TOTAL HEAT GAIN HG - SHG + LHG HEAT LOSS (HEATING LOADS) HG = 34657 BTUH A. TRANSMISSION LOSS: 1. GLASS: LTG : = GA• UG• (IW OW) LTG = 0 2. DOORS: LTWD := WD•WU•(IW OW) LTWD = 662 LTGD : = GD • GU • (I W OW) LTGD = 0 3. WALLS: LTW :_ NW + EW + SW + WW - GA)•UW•(IW OW) LTW = 3078 4. ROOF: LR : = R• RU• ( IW - OW) LR = 1512 5. FLOOR: LF := F• FU• (IW - OW) LF = 2722 TOTAL TRANSMISSION LOSS LT := LTG + LTWD + LTGD + LTW + LR + LF LT = 7974 B. DUCTS: LD LT•0.05 LD = 399 C. VENTILATION: LV OC• OA• (IW OW)-1-1 LV = 7128 TOTAL HEAT LOSS HL := LT + LD + LV HL = 15501 BTUH REFERENCE: ACCA MANUAL N FOURTH EDITION